Plan Review Notes
Plan Review Notes For Project Z12080011
Project Number Z12080011
Review Stop Z
Sequence Number 1
Notes
Date Text
2012-09-07 08:41:48 
 PLANS AND PLATS REVIEW COMMITTEE
 SEPTEMBER 12, 2012
 INFORMAL SITE PLAN REVIEW; PDQ RESTAURANT
 PB1020 D&E
  
 A REQUEST BY MICHAEL TROXELL OF BOHLEER ENGINEERING,
 LLC, ON BEHALF OF PDQ RESTAURANT, FOR THE APPROVAL OF
 AN INFORMAL SITE PLAN REVIEW IN ORDER TO CONSTRUCT A
 NEW 4,307 SQUARE FOOT RESTAURANT WITH A DRIVE-THRU.
  
 P.C.N. 74-43-43-19-01-000-0053
 2015 OKEECHOBEE BOULEVARD
  
 GENERAL COMMENTS:
  
 1. WHEN RESUBMITTING:
  
 A. PROVIDE WRITTEN RESPONSES TO REVIEW COMMENTS MADE BY
 ALL DEPARTMENTS IN A WRITTEN FORMAT WHEN RESUBMITTING.
 NOTE THAT RESUBMITTALS MAY BE SUBJECT TO ADDITIONAL
 COMMENTS.
  
 B. 15 SETS OF REVISED PLANS AND/OR DOCUMENTS SHALL BE
 PROVIDED, ALONG WITH ONE (1) REDUCED COPY (11IN X
 17IN), AND AN ELECTRONIC COPY OF ALL PLANS.
  
 C. IF NO RESPONSE IS RECEIVED WITHIN 60 DAYS OF THE
 ISSUANCE OF THESE COMMENTS, THE APPLICATION WILL BE
 CONSIDERED WITHDRAWN AND ANY FURTHER ACTION WILL
 REQUIRE SUBMISSION OF A NEW DEVELOPMENT APPLICATION.
  
 D. PLEASE NOTE THAT YOU WILL BE PERMITTED ONE (1)
 RESUBMITTAL AT NO ADDITIONAL COST. IF PREVIOUSLY-ISSUED
 COMMENTS CONTINUE TO NOT BE SUFFICIENTLY ADDRESSED, THE
 APPLICANT WILL BE ACCESSED A RESUBMITTAL FEE. SUCH FEE
 WILL BE 20% OF THE ORIGINAL APPLICATION FEE.
  
 2. THE APPLICANT SHOULD MEET WITH THE APPROPRIATE
 DISTRICT COMMISSIONER TO INFORM THEM OF THE PROPOSED
 REVISIONS TO THE PREVIOUSLY APPROVED DEVELOPMENT AS
 PART OF THE REVIEW PROCESS AND NOTIFY PLANNING STAFF OF
 THE OUTCOME OF THE MEETING AND ANY ISSUES THAT MAY NEED
 TO BE ADDRESSED BY THE APPLICANT.
  
 SITE/LANDSCAPE PLANS, JUSTIFICATION STATEMENTS, ETC:
  
 SITE PLAN:
  
 4. SHEET C-3 ? OVERALL SITE PLAN: DOES NOT DEPICT A
 PROPOSED LOCATION FOR SIGNAGE. WILL THE RESTAURANT
 UTILIZE THE EXISTING FREESTANDING SIGN LOCATED ON THE
 PROPERTY OR PROPOSE NEW SIGNAGE?
  
 5. THE BIKE RACK MODEL DEPICTED IN THE DETAIL OF PAGE
 C-7 IS NOT A MODEL THAT IS ACCEPTED BY THE CITY. PLEASE
 REFER TO THE ATTACHED BIKE PARKING GUIDE FOR MODELS
 THAT ARE ACCEPTABLE. IN ADDITION, THE BIKE PARKING
 DETAIL WILL NEED TO CONFORM TO THE MINIMUM SPACING
 REQUIREMENTS OUTLINED IN THE GUIDE. ALSO, PLEASE
 INCLUDE THE BIKE PARKING PAD DIMENSIONS IN THE SITE
 PLAN.
  
 LANDSCAPE PLAN:
  
 5. THE APPLICANT IS REQUESTED TO PROVIDE AN ADDITIONAL
 LANDSCAPE ISLAND ON THE NORTH SIDE OF THE DUMPSTER
 ENCLOSURE CONSISTING OF SHRUBS AND TREES AS SPECIFIED
 IN CHAPTER 94 ? ARTICLE XIV OF THE CITY?S LAND
 DEVELOPMENT CODE. PLEASE REVISE SHEET LP-1 AND
 CORRESPONDING PLANS TO REFLECT THE MODIFICATIONS.
  
 6. SHEET LP-1 - EXISITING TREE DISPOSITION CHART: TWO
 LIVE OAKS TO BE RELOCATED. PLEASE PROVIDE AN ADDITIONAL
 NOTE DEPICTING THE PROPOSED LOCATION FOR THE
 RELOCATION.
  
 ARCHITECTURAL ELEVATIONS:
  
 7. THE SIGNAGE DEPICTED ON SHEET A7-01 APPEARS ON THE
 SOUTH, EAST AND WEST ELEVATIONS. PLEASE PROVIDE A
 UNIFIED SIGNAGE PLAN IN ACCORDANCE WITH CHAPTER 94,
 ARTICLE XIII OF THE CITY?S LAND DEVELOPMENT CODE
 INCLUDING, SQUARE FOOTAGE CALCULATIONS FOR ALL OF THE
 PROPOSED SIGNAGE, METHOD OF ILLUMINATION, ETC. PLEASE
 BE ADVISED, ROOFTOP SIGNAGE IS PROHIBITED.
  
 MODIFICATION REQUEST LETTER TO SFWMD:
  
 8. THE FLOOR AREA CALCULATIONS ARE CONFLICTING BETWEEN
 THE MODIFICATION REQUEST LETTER TO SFWMD (3,841 SQUARE
 FEET) AND ALL OTHER PLANNING DOCUMENTS WHICH (THE SITE
 PLAN, SHEET C-3 ? SITE DATA) DEPICT AN OVERALL SQUARE
 FOOTAGE OF 4,307. PLEASE REVISE THE MODIFICATION
 LETTER.
  
 9. AT THE BOTTOM OF PAGE ONE, A SUMMARY PARAGRAPH IS
 PROVIDED BASED ON THE TABLE COMPARING THE EXISTING AND
 PROPOSED CONDITIONS FOR THE SITE. THERE APPEARS TO BE A
 TYPOGRAPHICAL ERROR WHICH STATES ??..RESULTS IN THE
 DECREASE OF THE PERVIOUS AREA BY??? THIS SHOULD READ
 ??..RESULTS IN THE DECREASE OF THE IMPERVIOUS AREA
 BY?..? PLEASE REVISE.
  
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT ME.
  
 BEST REGARDS,
  
 MURRIAH DEKLE, MPA, PLANNER
 CITY OF WEST PALM BEACH
 PLANNING AND ZONING DEPARTMENT
 401 CLEMATIS STREET - P.O. BOX 3366
 WEST PALM BEACH, FLORIDA 33402
  
 PHONE: 561.822.1442
 FAX: 561.822.1459
  
 EMAIL: [email protected]
  