Plan Review Notes
Plan Review Notes For Project Z12070019
Project Number Z12070019
Review Stop POLICE
Sequence Number 1
Notes
Date Text
2012-08-02 13:02:58CAMERA BOTH ENTRY VESTIBULES WITH MONITORS BEHIND
 TELLER LINES
 ARE THE RESTROOMS PUBLIC? IF SO THE DOORS LEADING TO
 THE DATA ROOM AND BREAKROOM NEED TO BE CARD ACCESS.
 CONSIDER A CAMERA MONITOR IN THE BREAKROOM
  
  
 A.ILLUMINATION FOR NIGHTTIME VISIBILITY IS REQUIRED.
 ADDRESS SHOULD BE PLACED UNDER A LIGHT FIXTURE OR BE
 BACK LIT.
 B.BI-DIRECTIONAL VISIBILITY FROM THE ROADWAY IS
 REQUIRED.
 C.ADDRESS SHOULD BE PLACED ON THE REAR OF THE BUILDING
 FOR POLICE
 D.ADDRESS NUMBERS ON DOORS SHALL BE A MINIMUM OF 6
 INCHES HIGH.
 E.ALL ENTRY DOORS (NON-GLASS SINGLE/DOUBLE) SHALL BE
 EQUIPPED WITH AN ASTRAGAL OVER THE THRESHOLD OF THE
 LOCKING MECHANISM AND CASE HARDENED DEADBOLT LOCKS
 SHALL BE PROVIDED ON ALL EXTERIOR DOORS WITH A MINIMUM
 ONE (1) INCH THROW OR MECHANICAL INTERLOCK. DOORS
 SECURED BY ELECTRICAL OPERATION SHALL HAVE A KEYED
 SWITCH OR SIGNAL LOCKING DEVICE TO OPEN THE DOOR WHEN
 IN LOCKED POSITION. GLASS EXTERIOR DOORS SHOULD HAVE A
 HOLDING FORCE OF AT LEAST 1000LBS. DOOR HINGES SHALL
 EMPLOY NON-REMOVABLE HINGES, AND THE MAIN ENTRIES TO
 THE BANK BUILDING SHALL BE WIRED FOR CLOSED CIRCUIT
 DIGITAL CAMERA SURVEILLANCE SYSTEM.
 F.INTERIOR DOORS TO OFFICES/MEETING ROOMS SHALL HAVE
 180 DEGREE PEEPHOLE OR VISION PANEL.
 G.EXTERIOR/INTERIOR PEDESTRIAN DOORS WHICH PROVIDE
 ACCESS INTO PARKING LOTS SHALL BE SOLID CORE AND WHERE
 APPLICABLE EMERGENCY DOORS SHALL HAVE NO EXTERIOR
 HANDLES. PANIC HARDWARE SHALL HAVE SELF LOCKING
 MECHANISM, MAY HAVE ONE LOCKING POINT BETWEEN THE DOORS
 AND FRAME, IT SHOULD EXTEND ONE INCH BEYOND EDGE OF THE
 DOOR TO WHICH IT IS ATTACHED.
 H TIMER CLOCK OR PHOTOCELL SENSOR-ENGAGED LIGHTING FOR
 ABOVE OR NEAR ENTRYWAYS TO BUILDINGS FOR DUSK TO DAWN
 OPERATION SHALL BE PROVIDED.
 I.BUILDING LIGHTING (NON-GLARE) SHALL BE AROUND
 PERIMETER ON ALL SIDES.
 J.MAIN EXIT DOORS SHALL HAVE HEIGHT MARKERS.
 K.ALARM SYSTEMS SHALL BE INSTALLED.
 L. HIGH-RESOLUTION COLOR DIGITAL VIDEO CAMERA SYSTEM
 WITH MONITORING AND PHOTO PROCESSING CAPABILITIES SHALL
 BE INSTALLED ABOVE EXIT DOORS, TELLER COUNTERS AND
 DRIVE-THRU LANES.
 M. MONEY LEVER SWITCHES WITHIN TELLER CASH DRAWERS THAT
 WILL ACTIVATE SYSTEM IN EMERGENCY SITUATIONS SHALL BE
 INSTALLED.
 N. DRIVE-THRU AREAS SHALL BE PROVIDED WITH ONE WAY
 DIRECTIONAL SIGNAGE.
 O. NIGHT DEPOSIT SHOULD BE LOCATED IN THE DRIVE- THRU
 LANE CLOSEST TO THE BUILDING WITH A COLOR DIGITAL VIDEO
 CAMERA TO CAPTURE TRANSACTIONS.
  
 AUTOMATED TELLER MACHINES
  
  ATM LOCATIONS SHALL BE IN AREAS WITH THE GREATEST
 NATURAL SURVEILLANCE AND INDEPENDENT FROM THE
 BUILDING.
 A. AUTOMATED TELLER MACHINES (ATM?S) SHALL COMPLY WITH
 FSS 655-966.
 B. ATM?S SHALL BE LOCATED ON MAIN ROADS IF APPLICABLE
 AND BE VISIBLE FROM THE ROADWAY.
 C. ATM?S SHALL NOT BE HIDDEN BY ANY LANDSCAPING OR
 OTHER FIXED OBJECT THAT WOULD PREVENT CLEAR VISIBILITY.
 D. ATM?S SHALL HAVE HIGH-RESOLUTION COLOR DIGITAL VIDEO
 CAMERA SYSTEM INSTALLED.
 E. ATM?S SHALL HAVE HIGH ILLUMINATION OF WALKWAYS
 LEADING TO AND FROM IT.
 F. LIGHTING SHALL BE POSITIONED SO AS NOT TO CAUSE
 GLARE ON VIDEO RECORDING.
 G. CONVEX MIRROR SHALL BE INSTALLED AND STRATEGICALLY
 PLACED TO ALLOW ATM OPERATOR TO IDENTIFY ANY
 APPROACHING PERSON(S) AND/OR POTENTIAL SUSPECT(S).
 H. ATM?S SHALL HAVE AN ALARM SYSTEM COMPONENTS, SHOCK
 AND SEISMIC SENSORS, SUFFICIENT WEIGHT AND TENSILE
 STRENGTH, HEAT DETECTORS, DOOR CONTACTS AND LOCKING
 MECHANISMS, TO DETER ATTACKS TO THE MACHINE ITSELF.
 DEVICES ARE NEEDED TO PROVIDE EARLY WARNING OF AN
 IMPENDING ATTACK.
 I. ATM?S SHOULD HAVE DURESS ALARMS AND A SECURE CLOSET
 TO SERVICE THE MACHINE.
  
  
  
 CONDITIONS FOR APPROVAL
 PRIOR TO ISSUANCE OF THE FIRST BUILDING PERMIT, THE
 APPLICANT SHALL PREPARE A CONSTRUCTION SITE SECURITY
 AND MANAGEMENT PLAN FOR APPROVAL BY THE CITY OF WEST
 PALM BEACH POLICE DEPARTMENT CPTED OFFICIAL.
 A.AFTER SITE CLEARING AND PLACEMENT OF CONSTRUCTION
 TRAILERS, THE DEVELOPER/PROJECT MANAGER SHALL INSTITUTE
 SECURITY MEASURES TO REDUCE OR ELIMINATE OPPORTUNITIES
 FOR THEFT. THE MANAGEMENT PLAN SHALL INCLUDE, BUT NOT
 BE LIMITED TO, TEMPORARY LIGHTING, SECURITY PERSONNEL,
 VEHICLE BARRIERS, CONSTRUCTION/VISITOR PASS,
 REDUCE/MINIMIZE ENTRY/EXIT POINTS, ENCOURAGE
 SUBCONTRACTORS TO SECURE MACHINERY, TOOLS AT END OF
 WORK DAY, FENCING WITH SCREENING AND OR ANY OTHER
 MEASURE DEEMED APPROPRIATE TO PROVIDE A SAFE AND SECURE
 WORKING ENVIRONMENT.
 B.THE SECURITY MANAGEMENT PLAN SHALL BE MAINTAINED
 THROUGHOUT THE CONSTRUCTION PHASE OF THE PROJECT.
 NON-COMPLIANCE WITH THE APPROVED PLAN SHALL RESULT IN A
 STOP-WORK ORDER FOR THE ENTIRE PLANNED UNIT
 DEVELOPMENT.
 C.PROPERTY SHALL BE POST ?NO TRESPASSING? SIGNS EVERY
 500 FEET AROUND THE PERIMETER OF THE SITE.
  
  
  
  