| Date |
Text |
| 2012-08-02 14:15:39 | CARD ACCESS INTO THE BUILDING SHOULD BE USED TO CONTROL |
| | ENTRY INTO THE BUILDING FOR RESIDENTS AND EMPLOYEES. |
| | VIDEO-CAMERAS SHOULD BE USED TO MONITOR THE PREMISES, |
| | THE LIVING ROOM AREAS, DINING ROOM, ENTRY DOORS, |
| | ELEVATOR AND STAIRWELL ENTRIES. |
| | THE ASSISTED LIVING FACILITY WILL NEED ANY AUXILIARY |
| | ENTRANCES LOCKED OR REQUIRE A CARD KEY OR NUMERIC CODE |
| | TO GAIN ACCESS. |
| | EMERGENCY BUTTONS IN THE APARTMENTS. |
| | |
| | RESIDENT DOORS SHOULD HAVE PEEPHOLES AND LOCKS THAT ARE |
| | EASY TO OPERATE, FOR PATIENTS WHO ARE WEAK OR WHO MAY |
| | HAVE ARTHRITIS. |
| | |
| | ALL DOORS RESIDENT DOORS SHALL BE EQUIPPED WITH SINGLE |
| | CYLINDER DEAD BOLT LOCK WITH A MINIMUM THROW OF ONE |
| | INCH AND AN EMBEDMENT OF NOT LESS 5/8 INCH INTO THE |
| | HOLDING DEVICE. PICK PLATES SHOULD ALSO BE PLACED ALL |
| | EXTERIOR DOORS. DOORS LEADING INTO A RESIDENTIAL UNIT |
| | SHALL BE SOLID CORE. |
| | |
| | WILL THERE BE A RECEPTIONIST?S DESK IN BOTH LIVING ROOM |
| | AREAS? VISITORS WILL NEED TO CHECK-IN BEFORE SEEING |
| | RESIDENTS |
| | |
| | EXIT DOOR ALARMS OR OTHER SYSTEM MUST BE PROVIDED FOR |
| | SECURITY PURPOSES AND TO ALERT STAFF WHEN RESIDENTS |
| | EXIT THE FACILITY |
| | |
| | CONVEX MIRRORS SHALL BE INSTALLED IN STAIRWELL ENABLING |
| | VIEWS OF UPPER AND LOWER STAIRWAYS. |
| | |
| | TIMER CLOCK OR PHOTOCELL SENSOR-ENGAGED LIGHTING FOR |
| | ABOVE OR NEAR ENTRYWAYS TO RESIDENCES PROVIDE FOR DUSK |
| | TO DAWN OPERATION. |
| | |
| | ENTRANCE SIGN LIGHTING SHALL BE PROVIDED. DIRECTORY |
| | SHOULD BE AT ALL ENTRANCES WITH LIGHTING. |
| | |
| | BUILDING LIGHTING (NON GLARE) SHALL BE AROUND PERIMETER |
| | ON ALL SIDES. |
| | |
| | NUMERICAL ADDRESS |
| | A. ILLUMINATION FOR NIGHTTIME VISIBILITY IS REQUIRED. |
| | ADDRESS SHOULD BE PLACED UNDER A LIGHT FIXTURE OR BE |
| | BACK LIT. |
| | B. ADDRESS NUMERALS SHALL BE OF A CONTRASTING COLOR TO |
| | THE BUILDING COLOR |
| | C. BI-DIRECTIONAL VISIBILITY FROM THE ROADWAY IS |
| | REQUIRED. |
| | D. ADDRESS NUMBERS ON DOORS OF MULTI-UNITS AND SINGLE |
| | FAMILY HOMES NEED TO BE A MINIMUM OF 6 INCHES HIGH. |
| | E. BUILDING NUMBERS FOR MULTI-UNIT BUILDINGS SHALL BE A |
| | MINIMUM OF 12 INCHES HIGH AND PLACED IN A CONSPICUOUS |
| | LOCATION ON ALL SIDES WITH PUBLIC ACCESS, AWAY FROM |
| | LANDSCAPING. |
| | |
| | 10.1 CONDITIONS FOR APPROVAL |
| | PRIOR TO ISSUANCE OF THE FIRST BUILDING PERMIT, THE |
| | APPLICANT SHALL PREPARE A CONSTRUCTION SITE SECURITY |
| | AND MANAGEMENT PLAN FOR APPROVAL BY THE CITY OF WEST |
| | PALM BEACH POLICE DEPARTMENT CPTED OFFICIAL. |
| | A.AFTER SITE CLEARING AND PLACEMENT OF CONSTRUCTION |
| | TRAILERS, THE DEVELOPER/PROJECT MANAGER SHALL INSTITUTE |
| | SECURITY MEASURES TO REDUCE OR ELIMINATE OPPORTUNITIES |
| | FOR THEFT. THE MANAGEMENT PLAN SHALL INCLUDE, BUT NOT |
| | BE LIMITED TO, TEMPORARY LIGHTING, SECURITY PERSONNEL, |
| | VEHICLE BARRIERS, CONSTRUCTION/VISITOR PASS, |
| | REDUCE/MINIMIZE ENTRY/EXIT POINTS, ENCOURAGE |
| | SUBCONTRACTORS TO SECURE MACHINERY, TOOLS AT END OF |
| | WORK DAY, FENCING WITH SCREENING AND OR ANY OTHER |
| | MEASURE DEEMED APPROPRIATE TO PROVIDE A SAFE AND SECURE |
| | WORKING ENVIRONMENT. |
| | B.THE SECURITY MANAGEMENT PLAN SHALL BE MAINTAINED |
| | THROUGHOUT THE CONSTRUCTION PHASE OF THE PROJECT. |
| | NON-COMPLIANCE WITH THE APPROVED PLAN SHALL RESULT IN A |
| | STOP-WORK ORDER FOR THE ENTIRE PLANNED UNIT |
| | DEVELOPMENT. |
| | C.PROPERTY SHALL BE POST ?NO TRESPASSING? SIGNS EVERY |
| | 500 FEET AROUND THE PERIMETER OF THE SITE. |
| | |
| | |
| | |
| |