| Date |
Text |
| 2012-07-06 09:15:16 | QUESTIONS: |
| | |
| | * HOW WILL PEDESTRIAN ACCESS GATES BE CONTROLLED? |
| | * CAMERA FOR VEHICLE EXITS |
| | * ACCESS CONTROL FOR THE POOL, CLUBHOUSE AREA, BOWLING, |
| | GAME ROOMS? |
| | * THE MAILROOM ACCESS? WILL THERE BE GLASS DOORS OR |
| | WILL IT BE OPEN? |
| | * CONSIDER MOVING THE GATES PAST THE MAIL ROOM, TO |
| | CONTROL ACCESS |
| | * GLASS DOORS SHOULD BE USED FOR THE GAME ROOM AND |
| | BOWLING AREA FOR EASY SURVEILLANCE |
| | * PRE WIRE THE CLUBHOUSE AREA FOR CCTV & ALARM |
| | * ALL BREEZEWAY AREAS SHOULD BE WELL LIT THROUGH OUT |
| | THE PROJECT |
| | * DID NOT SEE LIGHTING FOR THE CLUBHOUSE AREA |
| | * STAIRWELL ACCESS? INSTALL MIRRORS IN THE STAIRWELLS; |
| | FENCE OFF ANY UNDER STAIR CASE OPENINGS |
| | * CONSIDER A WINDOW IN THE REAR OF THE GUARDHOUSE IN |
| | ORDER TO SEE WHAT/WHO IS APPROACHING |
| | * NO SEATING UNDER THE TOWER STRUCTURE, LIGHTING? |
| | * IS THAT A SIDEWALK ENTRY FROM THE MAIN DRIVE INTO THE |
| | DEVELOPMENT (BLDG 4), IT IS UNGATED |
| | * WHO IS RESPONSIBLE FOR LIGHTING, LANDSCAPE MAINTAIN |
| | FOR THE TURQUOISE NECKLACE PATH?S |
| | * TOT LOT IS FENCED, BUT HEDGE NEEDS TO BE NO MORE THAT |
| | 2' IN HEIGHT. |
| | |
| | LIGHTING |
| | A. PARKING LOT LIGHTING SHALL USE 20 FOOT POLES. |
| | B. LANDSCAPING SHALL NOT OBSTRUCT VIEW OF WINDOWS, |
| | BUILDING ADDRESS NUMBERS, LIGHTING AND WALKWAYS. |
| | C. TIMER CLOCK OR PHOTOCELL SENSOR-ENGAGED LIGHTING FOR |
| | ABOVE OR NEAR ENTRYWAYS TO RESIDENCES PROVIDE FOR DUSK |
| | TO DAWN OPERATION. |
| | D. ENTRANCE SIGN LIGHTING SHALL BE PROVIDED. DIRECTORY |
| | SHOULD BE AT ALL ENTRANCES WITH LIGHTING. |
| | E. BUILDING LIGHTING (NON GLARE) SHALL BE AROUND |
| | PERIMETER ON ALL SIDES. |
| | |
| | MAIL BOX LOCATION |
| | |
| | A. MAILBOX LOCATIONS SHALL BE IN A WELL LIT, HIGH |
| | TRAFFIC LOCATION. |
| | |
| | |
| | NUMERICAL ADDRESS |
| | |
| | A. ILLUMINATION FOR NIGHTTIME VISIBILITY IS REQUIRED. |
| | ADDRESS SHOULD BE PLACED UNDER A LIGHT FIXTURE OR BE |
| | BACK LIT. |
| | B. ADDRESS NUMERALS SHALL BE OF A CONTRASTING COLOR TO |
| | THE BUILDING COLOR |
| | C. BI-DIRECTIONAL VISIBILITY FROM THE ROADWAY IS |
| | REQUIRED. |
| | D. ADDRESS NUMBERS ON DOORS OF MULTI-UNITS AND SINGLE |
| | FAMILY HOMES NEED TO BE A MINIMUM OF 6 INCHES HIGH. |
| | E. BUILDING NUMBERS FOR MULTI-UNIT BUILDINGS SHALL BE A |
| | MINIMUM OF 12 INCHES HIGH AND PLACED IN A CONSPICUOUS |
| | LOCATION ON ALL SIDES WITH PUBLIC ACCESS, AWAY FROM |
| | LANDSCAPING. NUMBERS SHOULD BE OF A CONTRASTING |
| | BACKGROUND. |
| | |
| | DOORS |
| | A. DOOR LEADING INTO A RESIDENTIAL UNIT, INCLUDING |
| | INTERIOR GARAGE, AND DETACHED GARAGE, SHALL BE SOLID |
| | CORE. |
| | B. FRONT DOOR SIDE PANE WINDOW SHALL BE PLACED ON THE |
| | OPPOSITE SIDE OF THE DOOR HANDLE AND LOCK MAKING THEM |
| | UNREACHABLE. |
| | C. EXTERIOR DOORS SHALL BE EQUIPPED WITH A 180-DEGREE |
| | PEEPHOLE AND NON-REMOVABLE SECURITY HINGES. |
| | LOCKS |
| | A. ANTI-LIFTING AUXILIARY LOCKS SHALL BE INSTALLED ON |
| | SLIDING DOORS AND WINDOWS. |
| | B. ALL DOORS SHALL BE EQUIPPED WITH SINGLE CYLINDER |
| | DEAD BOLT LOCK WITH A MINIMUM THROW OF ONE INCH AND AN |
| | EMBEDMENT OF NOT LESS 5/8 INCH INTO THE HOLDING DEVICE. |
| | PICK PLATES SHOULD ALSO BE PLACED ALL EXTERIOR DOORS. |
| | |
| | MISCELLANEOUS |
| | A. STAIRWAYS (TO INCLUDE RISERS/BANISTERS) AND |
| | BALCONIES SHALL PROVIDE OPEN VIEWS. |
| | B. SALES CENTER, CLUBHOUSE AND RECREATIONAL FACILITIES |
| | SHALL BE PRE-WIRED TO ALARM CENTER. |
| | C. RECREATION BUILDING AND POOL ACCESS SHALL BE |
| | RESTRICTED, BY KEY, KEY FOB, OR CARD ACCESS |
| | D. BICYCLE SPACES SHALL BE LOCATED IN CLOSE PROXIMITY |
| | TO THE FRONT OF BUILDINGS AND NOT IN PARKING LOTS. |
| | TRAILS AND PATHWAYS (TURQUOISE NECKLACE AREA) |
| | |
| | TRAILS AND PATHWAYS (TURQUOISE NECKLACE AREA) |
| | |
| | LIGHTING |
| | A. LIGHT POLES 10 ? 15 FOOT HIGH FOR PEDESTRIAN-SCALE |
| | LIGHTING SHALL BE USED FOR ALL PEDESTRIAN WALKWAYS. |
| | B. LANDSCAPING SHALL NOT CONFLICT WITH LIGHTING (TO |
| | INCLUDE LONG-TERM TREE CANOPY GROWTH). |
| | C. LIGHTING FOR ENTRANCE SIGN TO PATHWAYS SHALL BE |
| | PROVIDED TO ALLOW NIGHTTIME USE OF PEDESTRIAN WALKWAYS. |
| | |
| | DESIGN |
| | A. BENCHES SHALL HAVE ADEQUATE LIGHTING IF THEY ARE |
| | INTENDED FOR NIGHTTIME USE AND BE LOCATED IN OPEN VIEW |
| | TO ELIMINATE CONCEALMENT AREAS. |
| | B. BENCHES WILL BE DIVIDED STYLE SEATING. |
| | C. SHALL BE DESIGNED TO MAXIMIZE NATURAL SURVEILLANCE |
| | OF THE PEDESTRIAN USERS THROUGH SELECTIVE VEGETATIVE |
| | MANAGEMENT PRACTICES. |
| | D. GROUND COVER SHALL BE NO HIGHER THAN 24 INCHES, WITH |
| | TREES HAVING A MINIMUM 7-FOOT CLEAR TRUNK SPACE FOR A |
| | NATURAL SURVEILLANCE WINDOW. |
| | E. SIGHT LINES SHALL HAVE A 12-FOOT CLEAR DISTANCE |
| | SPACE AT ENTRY POINTS, CURVES, MERGERS, INTERSECTIONS, |
| | ETC. |
| | |
| | CONDITIONS FOR APPROVAL |
| | PRIOR TO ISSUANCE OF THE FIRST BUILDING PERMIT, THE |
| | APPLICANT SHALL PREPARE A CONSTRUCTION SITE SECURITY |
| | AND MANAGEMENT PLAN FOR APPROVAL BY THE CITY OF WEST |
| | PALM BEACH POLICE DEPARTMENT CPTED OFFICIAL. |
| | A. AFTER SITE CLEARING AND PLACEMENT OF CONSTRUCTION |
| | TRAILERS, THE DEVELOPER/PROJECT MANAGER SHALL INSTITUTE |
| | SECURITY MEASURES TO REDUCE OR ELIMINATE OPPORTUNITIES |
| | FOR THEFT. THE MANAGEMENT PLAN SHALL INCLUDE, BUT NOT |
| | BE LIMITED TO, TEMPORARY LIGHTING, SECURITY PERSONNEL, |
| | VEHICLE BARRIERS, CONSTRUCTION/VISITOR PASS, |
| | REDUCE/MINIMIZE ENTRY/EXIT POINTS, ENCOURAGE |
| | SUBCONTRACTORS TO SECURE MACHINERY, TOOLS AT END OF |
| | WORK DAY, FENCING WITH SCREENING AND OR ANY OTHER |
| | MEASURE DEEMED APPROPRIATE TO PROVIDE A SAFE AND SECURE |
| | WORKING ENVIRONMENT. |
| | B. THE SECURITY MANAGEMENT PLAN SHALL BE MAINTAINED |
| | THROUGHOUT THE CONSTRUCTION PHASE OF THE PROJECT. |
| | NON-COMPLIANCE WITH THE APPROVED PLAN SHALL RESULT IN A |
| | STOP-WORK ORDER FOR THE ENTIRE PLANNED UNIT |
| | DEVELOPMENT. |
| | C. PROPERTY SHALL BE POST ?NO TRESPASSING? SIGNS EVERY |
| | 500 FEET AROUND THE PERIMETER OF THE SITE. |
| | |
| | |
| | |
| | |
| |
Print |