| Plan Review Notes For Project Z12040011 |
| Project Number |
Z12040011 |
|
| Review Stop |
STORM |
| Sequence Number |
2 |
|
| Notes |
| Date |
Text |
| 2012-07-18 14:12:46 | 1. PROVIDE A DETAIL ON HOW DEAD END EXFILTRATION | | | TRENCHES (ATTACHED TO STRUCTURES 1, 8 AND 9) ARE TO BE | | | TERMINATED (I.E. END CAP, 4-FT SECTION OF | | | NON-PERFORATED PIPE, OPEN END WRAPPED WITH FILTER | | | CLOTH, ETC.). WHAT WILL BE THE PIPE SLOPE OR PIPE | | | INVERT ELEVATION AT THE DEAD END? | | | 2. PLEASE INDICATE IF THE OUTFALL PIPES FROM THE TWO | | | EXISTING STRUCTURES NEAR STRUCTURES 4 AND 5 WILL | | | CONTINUE TO DISCHARGE STORMWATER RUNOFF? IF NOT, WOULD | | | YOU CONSIDER REMOVING/ABANDONING THE EXISTING | | | STRUCTURES AND OUTFALL PIPES? | | | | | | TRACY L. WARD, P.E. | | | SENIOR STORM WATER ENGINEER | | | ENGIENEERING SERVICES DEPARTMENT | | | 561-494-1120 |
| |