| 2012-07-06 13:57:10 | BELOW ARE COMMENTS FROM MAY 9, 2012, I DID NOT SEE |
| | THESE COMMENTS ADDRESSED. (I TOOK OUT THE COMMENTS THAT |
| | WERE ADDRESSED ON THE PLANS.) |
| | |
| | ALL STORE DOORS EXITING INTO THE SERVICE AREAS NEED |
| | PEEP/VIEW HOLES |
| | |
| | WHERE WILL THE PALM TRAN BUS STOP LOCATED? |
| | |
| | WILL BE LOOKING FOR: |
| | |
| | 1. NUMERICAL ADDRESSES SHALL BE PLACED AT THE FRONT AND |
| | REAR OF THE BUILDING. EACH NUMERICAL ADDRESS SHALL BE |
| | ILLUMINATED FOR NIGHTTIME VISIBILITY WITH AN |
| | UNINTERRUPTIBLE A.C. POWER SOURCE, SHALL CONSIST OF SIX |
| | (6) INCH HIGH NUMBERS AND SHALL BE A DIFFERENT COLOR |
| | THAN THE COLOR OF THE SURFACE TO WHICH IT IS ATTACHED. |
| | THE REAR DOORS OF THE BUILDING SHALL HAVE AN |
| | ILLUMINATED 6 INCH NUMBER ON OR ALONG SIDE THE DOOR. |
| | |
| | 2. PROVIDE PHOTOCELL SENSOR ENGAGED DUSK TO DAWN |
| | LIGHTING IN THE REAR OF THE BUILDING. |
| | |
| | 3. DOORS SHALL BE EQUIPPED WITH METAL PLATE OVER |
| | THRESHOLD OF THE LOCKING MECHANISM. (FRONT AND REAR) |
| | |
| | 4. ALL DOORS THAT EXIT OUT SHALL HAVE A 180 DEGREE VIEW |
| | HOLES. |
| | |
| | 5. CASE HARDENED COMMERCIAL GRADE DEAD BOLT LOCKS SHALL |
| | BE INSTALLED ON ALL STORE FRONTS AND AREA DOORS WITH |
| | MINIMUM OF ONE INCH THROW INTO THE STRIKE RECEIVING THE |
| | BOLT. THE CYLINDER SHALL HAVE A CYLINDER GUARD (SPIN |
| | GUARD) AND A MINIMUM OF FIVE-PIN TUMBLERS. |
| | |
| | 6. ALL STORE FRONTS SHOULD HAVE IMPACT RESISTANT GLASS |
| | OR HAVE BURGLARY RESISTANT GLAZING |
| | |
| | 7. DOORS SECURED BY ELECTRICAL OPERATION SHALL HAVE A |
| | KEY PAD-SWITCH TO OPEN THE DOOR WHEN IN A CLOSED |
| | POSITION, OR BY A SIGNAL LOCKING DEVICE. |
| | |
| | 8. IF INSTALLED, BENCHES SHALL BE DIVIDED STYLE AND |
| | HAVE ADEQUATE LIGHTING IN THE AREA THEY ARE LOCATED. |
| | BENCHES SHOULD ALSO BE IN OPEN VIEW TO ELIMINATE |
| | CONCEALMENT AREAS. |
| | |
| | ADDITIONAL COMMENTS/QUESTIONS: |
| | |
| | * WILL THERE BE A KIOSK AT THE VALET AREA? PLEASE |
| | INDICATE WHAT WILL BE USED TO SECURE THE KEYS OF THE |
| | CUSTOMERS |
| | * WILL THERE BE ATM LOCATIONS INSIDE THE MALL PLAZA? |
| | * I WOULD LIKE TO SEE THE FIXTURES THAT WILL BE USED |
| | INSIDE THE MALL PLAZA AND LOCATIONS |
| | * WILL VIEW WINDOWS/PEEP HOLES BE INSTALLED IN ALL REAR |
| | EXITING DOORS OF ALL STORES? |
| | |
| | PLEASE ADHERE TO THE CONSTRUCTION SITE SECURITY PLAN |
| | THAT WAS SUBMITTED AT THE START OF THE PROJECT. |
| | REMEMBER THAT THE PD WILL NEED GATE ACCESS ONCE THE |
| | FENCE IS INSTALLED. |
| | |
| | ADDITIONAL INFORMATION WILL BE REQUESTED, AND THE |
| | POLICE DEPARTMENT WILL HAVE ADDITIONAL COMMENTS AS THE |
| | PROCESS CONTINUES. THE CRIME PREVENTION OFFICER WILL |
| | PERIODICALLY BE ON SITE TO ENSURE CPTED PLANS AND THE |
| | CONSTRUCTION SITE SECURITY PLAN IS BEING FOLLOWED. |
| | |
| | |
| |