Plan Review Notes
Plan Review Notes For Project Z12040009
Project Number Z12040009
Review Stop POLICE
Sequence Number 1
Notes
Date Text
2012-05-09 10:37:43ON THE PARKING LOT/PEDESTRIAN LIGHTING FOR THE PB
 OUTLET MALL, I WOULD LIKE SEE LED LIGHTING. LED
 LIGHTING IS A BETTER QUALITY GIVING A BRIGHTER, WHITER
 LIGHT. LED?S CONSUME 50% TO 90% LESS POWER THEY ARE
 EXTREMELY DURABLE AND HAVE MORE LONGEVITY THAN METAL
 HALIDE. LEDS ARE INITIALLY EXPENSIVE, ALTHOUGH THE COST
 IS RECOUPED OVER TIME IN ENERGY, POWER AND REPLACEMENT
 SAVINGS.
  
 LANDSCAPE PLAN IN PARKING LOT DOES NOT SEEM TO
 INTERFERE WITH THE LIGHT POLES THAT ARE SHOWN, BUT I
 WOULD LIKE A SEPARATE PLAN SHOWING ME THE LIGHTING
 LAYOUT FOR THE PARKING LOT AND THE FIXTURES/HEADS TO BE
 USED.
  
 IN ADDITION PLEASE SHOW ME THE PEDESTRIAN LIGHTING AND
 THE FIXTURES TO BE USED, ON THE PLAN NOW IT APPEARS
 THEY ARE OPEN FIXTURES, NOT FULL CUTOFF. A FULL CUTOFF
 LIGHTING FIXTURE WILL CREATE ESSENTIALLY NO GLARE. ALL
 THE LIGHT IS USED, NONE IS WASTED.
  
 CONSIDER A KIOSK BY THE TOUR BUS LOADING/UNLOADING AREA
  
 ALL STORE DOORS EXITING INTO THE SERVICE AREAS NEED
 PEEP/VIEW HOLES
  
 WHERE WILL THE PALM TRAN BUS STOP LOCATED?
  
  
  
  
  
 BLDG H-9 WILL BE LOOKING FOR:
  
 1. NUMERICAL ADDRESSES SHALL BE PLACED AT THE FRONT AND
 REAR OF THE BUILDING. EACH NUMERICAL ADDRESS SHALL BE
 ILLUMINATED FOR NIGHTTIME VISIBILITY WITH AN
 UNINTERRUPTIBLE A.C. POWER SOURCE, SHALL CONSIST OF
 TWELVE (12) INCH HIGH NUMBERS AND SHALL BE A DIFFERENT
 COLOR THAN THE COLOR OF THE SURFACE TO WHICH IT IS
 ATTACHED. THE REAR DOORS OF THE BUILDING SHALL HAVE AN
 ILLUMINATED 6 INCH NUMBER ON OR ALONG SIDE THE DOOR.
  
 2. ALL ON-SITE LIGHTING SHALL CONSIST OF METAL HALIDE
 (OR EQUIVALENT LIGHTING APPROVED BY THE POLICE
 DEPARTMENT) WITH FULL CUT OFF FIXTURE AND LIGHTING
 SHALL NOT CONFLICT WITH PLANTED LANDSCAPING. LUMINARY
 TYPE SHOULD OPTIMIZE LIGHT DISTRIBUTION AND MINIMIZE
 GLARE AN UP LIGHTING.
  
 3. PROVIDE PHOTOCELL SENSOR ENGAGED DUSK TO DAWN
 LIGHTING IN THE REAR OF THE BUILDING.
  
 4. DOORS SHALL BE EQUIPPED WITH METAL PLATE OVER
 THRESHOLD OF THE LOCKING MECHANISM. (FRONT AND REAR)
  
 5. ALL DOORS THAT EXIT OUT SHALL HAVE A 180 DEGREE VIEW
 HOLES.
  
 6. CASE HARDENED COMMERCIAL GRADE DEAD BOLT LOCKS SHALL
 BE INSTALLED ON ALL STORE FRONTS AND AREA DOORS WITH
 MINIMUM OF ONE INCH THROW INTO THE STRIKE RECEIVING THE
 BOLT. THE CYLINDER SHALL HAVE A CYLINDER GUARD (SPIN
 GUARD) AND A MINIMUM OF FIVE-PIN TUMBLERS.
  
 7. ALL STORE FRONTS SHOULD HAVE IMPACT RESISTANT GLASS
 OR HAVE BURGLARY RESISTANT GLAZING
  
 8. DOORS SECURED BY ELECTRICAL OPERATION SHALL HAVE A
 KEY PAD-SWITCH TO OPEN THE DOOR WHEN IN A CLOSED
 POSITION, OR BY A SIGNAL LOCKING DEVICE.
  
 9. INSTALL TWELVE FOOT (12) PEDESTRIAN SCALE LIGHTING
 WITH FULL CUT OFF FIXTURES ALONG WALKWAYS.
  
 10. IF INSTALLED, BENCHES SHALL BE DIVIDED STYLE AND
 HAVE ADEQUATE LIGHTING IN THE AREA THEY ARE LOCATED.
 BENCHES SHOULD ALSO BE IN OPEN VIEW TO ELIMINATE
 CONCEALMENT AREAS.
  
 11.IF BIKE RACKS ARE INSTALLED THEY SHOULD BE AT THE
 FRONT OF THE BUILDING FOR EASY SURVEILLANCE AND SAFETY.
  
 ADDITIONAL INFORMATION WILL BE REQUESTED, AND THE
 POLICE DEPARTMENT WILL HAVE ADDITIONAL COMMENTS AS THE
 REVIEW PROCESS CONTINUES. THE CRIME PREVENTION OFFICER
 WILL PERIODICALLY BE ON SITE TO ENSURE CPTED PLANS ARE
 BEING FOLLOWED.
  