Plan Review Notes
Plan Review Notes For Project Z10110008
Project Number Z10110008
Review Stop POLICE
Sequence Number 1
Notes
Date Text
2010-12-07 10:24:18WHAT LIGHTING WILL BE INSTALLED. LOOKING FOR PEDESTRIAN
 SCALE ALONG THE PTHS AND SIDEWALK, PAVILLION STRUCTURE.
 MOVE THE BIKE RACKS TO A MORE HIGH TRAFFIC AREA
 BENCHES SHOULD BE DIVIDED STYLE
  
 A. LANDSCAPING SHALL NOT CONFLICT WITH LIGHTING (TO
 INCLUDE LONG-TERM TREE CANOPY GROWTH).
 B. TIMER CLOCK OR PHOTOCELL SENSOR-ENGAGED LIGHTING FOR
 DUSK TO DAWN OPERATION FOR ALL PEDESTRIAN SIDEWALKS.
 C. LIGHTING FOR ENTRANCE SIGN TO PATHWAYS SHALL BE
 PROVIDED TO ALLOW NIGHTTIME USE OF PEDESTRIAN WALKWAYS.
 D. BENCHES WILL BE DIVIDED STYLE SEATING.
 E. SHALL BE DESIGNED TO MAXIMIZE NATURAL SURVEILLANCE
 OF THE PEDESTRIAN USERS THROUGH SELECTIVE VEGETATIVE
 MANAGEMENT PRACTICES.
 F. GROUND COVER SHALL BE NO HIGHER THAN 24 INCHES, WITH
 TREES HAVING A MINIMUM 7-FOOT CLEAR TRUNK SPACE FOR A
 NATURAL SURVEILLANCE WINDOW.
 G. INSTALL 12-FOOT PEDESTRIAN-SCALE LIGHTING. AS A
 GENERAL RULE, THE MINIMUM LIGHTING INTENSITY AT ANY
 POINT ALONG THE PATH SHALL BE AT 0.6 FOOT-CANDLES.
 H. SIGHT LINES SHALL HAVE A 12-FOOT CLEAR DISTANCE
 SPACE AT ENTRY POINTS, CURVES, MERGERS, INTERSECTIONS,
 ETC.
  
  Print


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved