2010-06-09 11:11:53* LIGHTING FOR THE PARKING LOT AND BUILDING EXTERIOR?
 * LOCKS?
 * SIGNS SHALL CLEARLY IDENTIFY PUBLIC ENTRANCES
 * CONVEX MIRRORS SHALL BE INSTALLED IN STAIRWELL
 ENABLING VIEWS OF UPPER AND LOWER STAIRWAYS.
 * REAR DOORS SHALL BE EQUIPPED WITH 180-DEGREE
 PEEPHOLE/ SECURITY VIEWER
 * EXTERIOR DOORS SHALL ALL BE EQUIPPED WITH SECURITY
 HINGES AND SHALL BE REINFORCED WITH CASE HARDENED
 STRIKE PLATES. CASE HARDENED DEADBOLT LOCKS SHALL BE
 PROVIDED ON ALL EXTERIOR DOORS WITH A MINIMUM (1) INCH
 THROW OR MECHANICAL INTERLOCK.
 * ACCESS CONTROL FOR PATIO AREA?
 * ACCESS CONTROL FOR THE LOBBY AREA, CONSIDER OPENING
 UP THE RECEPTION DESK, BY GLASS OR REMOVING THE SIDE
 WALL FOR BETTER VIEW OF THE LOBBY AREA AND HALLWAY
 * CAMERA/CCTV ?
 * ACCESS CONTROL FOR SENSITIVE AREAS?
  
  
 10.1 CONDITIONS FOR APPROVAL
 PRIOR TO ISSUANCE OF THE FIRST BUILDING PERMIT, THE
 APPLICANT SHALL PREPARE A CONSTRUCTION SITE SECURITY
 AND MANAGEMENT PLAN FOR APPROVAL BY THE CITY OF WEST
 PALM BEACH POLICE DEPARTMENT CPTED OFFICIAL.
 A. AFTER SITE CLEARING AND PLACEMENT OF CONSTRUCTION
 TRAILERS, THE DEVELOPER/PROJECT MANAGER SHALL INSTITUTE
 SECURITY MEASURES TO REDUCE OR ELIMINATE OPPORTUNITIES
 FOR THEFT. THE MANAGEMENT PLAN SHALL INCLUDE, BUT NOT
 BE LIMITED TO, TEMPORARY LIGHTING, SECURITY PERSONNEL,
 VEHICLE BARRIERS, CONSTRUCTION/VISITOR PASS,
 REDUCE/MINIMIZE ENTRY/EXIT POINTS, ENCOURAGE
 SUBCONTRACTORS TO SECURE MACHINERY, TOOLS AT END OF
 WORK DAY, FENCING WITH SCREENING AND OR ANY OTHER
 MEASURE DEEMED APPROPRIATE TO PROVIDE A SAFE AND SECURE
 WORKING ENVIRONMENT.
 B. THE SECURITY MANAGEMENT PLAN SHALL BE MAINTAINED
 THROUGHOUT THE CONSTRUCTION PHASE OF THE PROJECT.
 NON-COMPLIANCE WITH THE APPROVED PLAN SHALL RESULT IN A
 STOP-WORK ORDER FOR THE ENTIRE PLANNED UNIT
 DEVELOPMENT.
 C. PROPERTY SHALL BE POST ???NO TRESPASSING??? SIGNS
 EVERY 500 FEET AROUND THE PERIMETER OF THE SITE.
  
  
  
  
  
  
 PPRC: APRIL 8, 2009
  
  
 ZBA CASE NO. 3246
 CLASS B SPECIAL USE PERMIT
 BESHANT HEALTH CARE, INC.
  
  
 COMMENTS:
 DRIVEWAY ENTERING PROPERTY NEEDS LIGHTING AND TREE
 TRIMMING.
 SECURITY SYSTEM SHOULD BE REPAIRED/INSTALLED TO COVER
 HIGH TRAFFIC AREAS: LOBBIES, DELIVERY AREA, PUBLIC
 ACCESS ROOMS, BALCONIES, PARKING LOTS.
 ENTRY IN TO THE LOBBY SHOULD BE CONTROLLED ACCESS
 FENCING NEEDS REPAIR, HEDGES TRIMMED DOWN OR CLEARED
 OUT
 UPGRADE LOCKS
 INSTALL PEEPHOLES IN DOORS LEADING OUTSIDE
  
 CPTED REQUIREMENTS
  
 THE FOLLOWING SUGGESTIONS ARE MADE FOR THE PURPOSE OF
 REDUCING THE LIKELIHOOD OF CRIMINAL ACTIVITY. WHILE NO
 GUARANTEE CAN BE STATED OR IMPLIED, THE CONCEPTS OF
 CPTED HAVE PROVEN THEMSELVES INTERNATIONALLY. THE WEST
 PALM BEACH POLICE DEPARTMENT OFFERS THESE SUGGESTIONS
 AS A PUBLIC SERVICE, WITH THE UNDERSTANDING THAT THERE
 IS NO WAY TO PREDICT OR PREVENT ALL CRIME RISKS. THE
 PURPOSE OF THESE REQUIREMENTS IS TO REDUCE FORMABILITY
 OF CRIME, BY MAKING A GOOD FAITH EFFORT TO PROVIDE A
 SAFE ENVIRONMENT.
 BELOW IS A LIST OF CRIME PREVENTION RECOMMENDATIONS TO
 HELP DETER CRIMINAL ACTIVITY.
 1.9 LIGHTING
 A. EXTERIOR LIGHTING SHALL BE METAL HALIDE
 B. LANDSCAPING SHALL NOT CONFLICT WITH LIGHTING (TO
 INCLUDE LONG-TERM TREE CANOPY GROWTH).
 C. LANDSCAPING SHALL NOT OBSTRUCT VIEW OF WINDOWS,
 BUILDING ADDRESS NUMBERS, AND WALKWAYS.
 D. TIMER CLOCK OR PHOTOCELL SENSOR-ENGAGED LIGHTING FOR
 ABOVE OR NEAR ENTRYWAYS AND ALL PEDESTRIAN SIDEWALKS
 SHALL BE PROVIDED.
 E. PARKING LOT LIGHTING SHOULD BE 25-FOOT POLES.
 F. PEDESTRIAN-SCALE LIGHTING SHALL BE USED FOR ALL
 STREET AND PEDESTRIAN WALKWAYS. IT IS SUGGESTED THAT
 12-FOOT LIGHT POLES BE USED FOR THE STREET LIGHTING.
 G. LIGHTING FOR ENTRANCE SIGN SHALL BE PROVIDED.
 H. LIGHTING ON BUILDINGS SHALL BE AROUND PERIMETER OF
 ALL SIDES AND ON PEDESTRIAN WALKWAY SURROUNDING THE
 BUILDINGS.
 1.10 NUMERICAL ADDRESS
 A. ILLUMINATED FOR NIGHTTIME VISIBILITY IS REQUIRED.
 B. BI-DIRECTIONAL VISIBILITY FROM THE ROADWAY IS
 REQUIRED.
 C. ADDRESS NUMBERS ON DOORS NEED TO BE A MINIMUM OF 6
 INCHES HIGH.
 D. BUILDING NUMBERS SHALL TO BE A MINIMUM OF 12 INCHES
 HIGH AND PLACED IN A CONSPICUOUS LOCATION AWAY FROM
 LANDSCAPING.
 1.11 EXTERIOR
 A. EXTERIOR BUILDING LIGHTING SHALL BE REQUIRED FOR ALL
 EXIT WAY, EMERGENCY ACCESS, STAIRWAY AND UTILITY ROOM
 DOORS.
 B. SECONDARY ACCESS, OTHER THAN MAIN LOBBY, SHALL BE
 AVAILABLE BY CONTROLLED ACCESS.
 C. MAIN ENTRANCE SHALL LEAD DIRECTLY TO THE FRONT LOBBY
 AREA WITH VISIBLE SIGNAGE INDICATING SO.
 D. TRAFFIC LEADING TO LOBBY OVERHANG AND/OR CIRCULAR
 DRIVE SHALL BE ONE WAY WITH SIGNAGE STATING SAME.
 E. STAIRWELLS SHALL HAVE CONVEX MIRRORS INSTALLED AT
 LANDINGS FOR EACH LEVEL.
 F. INTERIOR OF ELEVATORS SHALL UTILIZE MIRRORS AND CCTV
 G. INSTALL CCTV FOR SURVEILLANCE OF LOBBY, STAIRWELLS,
 PARKING LOTS AND SERVICE AREAS OF PUBLIC ACTIVITY
 ROOMS.
  