| Date |
Text |
| 2010-04-13 10:27:54 | QUESTIONS: |
| | |
| | * GUARD SHACK, HOW WILL ACCESS BE CONTROLLED? WILL IT |
| | BE CAMERA SURVEILLANCE? |
| | * HOW WILL ACCESS BE CONTROLLED AT THE BACK ENTRANCE? |
| | * WILL YOU RESTRICT ACCESS INTO THE EMPLOYEE PARKING |
| | AREA? BY SIGNAGE? |
| | * WELL LIT PATHWAYS/WALKWAYS AND SITTING AREA MUST HAVE |
| | GOOD LIGHTING IF THEY ARE INTENDED FOR NIGHT TIME USE. |
| | IF NOT FOR NIGHT TIME USE, HOW WILL ACCESS AFTER HOURS |
| | BE CONTROLLED? |
| | * IN THE LOBBY, THE GREETER???S DESK SHOULD BE MOVED TO |
| | THE CENTER OF THE LOBBY, CIRCULAR IN DESIGN TO COVER |
| | THE FRONT AND REAR ENTRY DOORS. ACCESS AND MOVEMENT |
| | PAST THE LOBBY AREAS SHOULD BE CONTROLLED. |
| | * RESTRICT ACCESS TO ALL EMPLOYEE AREAS WITH CARD OR |
| | CODE ACCESS |
| | * CONTROL OF VALET KEYS? |
| | * MEDICATION ROOMS SHOULD HAVE CARD OR CODE ACCESS |
| | * NO LIGHTING PLAN PROVIDED |
| | |
| | |
| | |
| | |
| | CONSTRUCTION SECURITY CONDITIONS FOR APPROVAL |
| | PRIOR TO ISSUANCE OF THE FIRST BUILDING PERMIT, THE |
| | APPLICANT SHALL PREPARE A CONSTRUCTION SITE SECURITY |
| | AND MANAGEMENT PLAN FOR APPROVAL BY THE CITY OF WEST |
| | PALM BEACH POLICE DEPARTMENT CPTED OFFICIAL. |
| | A. AFTER SITE CLEARING AND PLACEMENT OF CONSTRUCTION |
| | TRAILERS, THE DEVELOPER/PROJECT MANAGER SHALL INSTITUTE |
| | SECURITY MEASURES TO REDUCE OR ELIMINATE OPPORTUNITIES |
| | FOR THEFT. THE MANAGEMENT PLAN SHALL INCLUDE, BUT NOT |
| | BE LIMITED TO, TEMPORARY LIGHTING, SECURITY PERSONNEL, |
| | VEHICLE BARRIERS, CONSTRUCTION/VISITOR PASS, |
| | REDUCE/MINIMIZE ENTRY/EXIT POINTS, ENCOURAGE |
| | SUBCONTRACTORS TO SECURE MACHINERY, TOOLS AT END OF |
| | WORK DAY, FENCING WITH SCREENING AND OR ANY OTHER |
| | MEASURE DEEMED APPROPRIATE TO PROVIDE A SAFE AND SECURE |
| | WORKING ENVIRONMENT. |
| | B. THE SECURITY MANAGEMENT PLAN SHALL BE MAINTAINED |
| | THROUGHOUT THE CONSTRUCTION PHASE OF THE PROJECT. |
| | NON-COMPLIANCE WITH THE APPROVED PLAN SHALL RESULT IN A |
| | STOP-WORK ORDER FOR THE ENTIRE PLANNED UNIT |
| | DEVELOPMENT. |
| | C. PROPERTY SHALL BE POST ???NO TRESPASSING??? SIGNS |
| | EVERY 500 FEET AROUND THE PERIMETER OF THE SITE. |
| | |
| | PATHWAY DESIGN |
| | A. BENCHES SHALL HAVE ADEQUATE LIGHTING IF THEY ARE |
| | INTENDED FOR NIGHTTIME USE AND BE LOCATED IN OPEN VIEW |
| | TO ELIMINATE CONCEALMENT AREAS. |
| | B. SHALL BE DESIGNED TO MAXIMIZE NATURAL SURVEILLANCE |
| | OF THE PEDESTRIAN USERS THROUGH SELECTIVE VEGETATIVE |
| | MANAGEMENT PRACTICES. |
| | C. GROUND COVER SHALL BE NO HIGHER THAN 24 INCHES, WITH |
| | TREES HAVING A MINIMUM 7-FOOT CLEAR TRUNK SPACE FOR A |
| | NATURAL SURVEILLANCE WINDOW. |
| | D. INSTALL 12-FOOT PEDESTRIAN-SCALE LIGHTING. |
| | E. SIGHT LINES SHALL HAVE A 12-FOOT CLEAR DISTANCE |
| | SPACE AT ENTRY POINTS, CURVES, MERGERS, INTERSECTIONS, |
| | ETC. |
| | LIGHTING |
| | A. PARKING LOT AND PEDESTRIAN LIGHTING SHALL BE: |
| | A) HIGH EFFICACY OF GREATER THAN 70 LUMENS PER WATT |
| | B) A KELVIN TEMPERATURE OF 3,500 K OR GREATER THAN |
| | KELVIN TEMPERATURE |
| | C) COLOR RENDERING INDEX (CRI) OF 70 OR GREATER |
| | D) LAMP LIFE OF 20 THOUSAND HOURS OR GREATER. |
| | B. LIGHT POLES 10 ??? 15 FOOT HIGH FOR PEDESTRIAN-SCALE |
| | LIGHTING SHALL BE USED FOR ALL PEDESTRIAN WALKWAYS. |
| | C. PARKING LOT LIGHTING SHALL USE 20 -25 FOOT POLES. |
| | D. LANDSCAPING SHALL NOT OBSTRUCT VIEW OF WINDOWS, |
| | BUILDING ADDRESS NUMBERS, LIGHTING AND WALKWAYS. |
| | E. TIMER CLOCK OR PHOTOCELL SENSOR-ENGAGED LIGHTING FOR |
| | ABOVE OR NEAR ENTRYWAYS TO BUILDINGS FOR DUSK TO DAWN |
| | OPERATION SHALL BE PROVIDED. |
| | F. ENTRANCE SIGN LIGHTING SHALL BE PROVIDED. DIRECTORY |
| | SHOULD BE AT ALL ENTRANCES WITH LIGHTING |
| | G. BUILDING LIGHTING (NON-GLARE) SHALL BE AROUND |
| | PERIMETER ON ALL SIDE. |
| | |
| | |
| | DOORS |
| | |
| | A. EXTERIOR DOORS SHALL ALL BE EQUIPPED WITH SECURITY |
| | HINGES AND SHALL BE REINFORCED WITH CASE HARDENED |
| | STRIKE PLATES. CASE HARDENED DEADBOLT LOCKS SHALL BE |
| | PROVIDED ON ALL EXTERIOR DOORS WITH A MINIMUM (1) INCH |
| | THROW OR MECHANICAL INTERLOCK. |
| | B. GLASS PERIMETER DOORS SHALL BE EQUIPPED WITH CASE |
| | HARDENED GUARD RINGS TO PROTECT THE MORTISE LOCK |
| | CYLINDER. |
| | C. EXIT DOORS SHALL BE EQUIPPED WITH 180-DEGREE |
| | PEEPHOLE/ SECURITY VIEWER. |
| | |
| | DESIGN |
| | A. BUILDING ARCHITECTURE SHALL ALLOW FOR ENHANCED |
| | NATURAL SURVEILLANCE OF ALL PARKING LOTS AND PROVIDE A |
| | SENSE OF SECURITY TO PATRONS AND VISITORS. |
| | B. CROSSWALKS SHALL BE RAISED AND DELINEATED BY USING |
| | CONTRASTING PAVER BLOCKS AS OPPOSED TO SURFACE |
| | STRIPING. |
| | C. ALL BUILDINGS SHALL BE PRE-WIRED FOR CLOSED-CIRCUIT |
| | TELEVISION (CCTV) AND ALARM SYSTEMS. |
| | D. DUMPSTERS SHALL NOT ALLOW FOR EASY CONCEALMENT, |
| | CREATE BLIND SPOTS OR HIDING AREAS AND SHOULD BE ABLE |
| | TO BE LOCKED. |
| | E. SIGNS SHALL CLEARLY IDENTIFY PUBLIC ENTRANCES. |
| | F. LANDSCAPING SHALL BE MAINTAINED AT 3 FEET OR LESS. |
| | TREES SHALL BE INSTALLED SO AS NOT TO CONFLICT WITH THE |
| | LIGHTING SYSTEM. LOWER CANOPY LIMBS ON TREES SHALL BE |
| | MAINTAINED AT 8 FEET OR HIGHER. |
| | G. CONVEX MIRRORS SHALL BE INSTALLED IN STAIRWELL |
| | ENABLING VIEWS OF UPPER AND LOWER STAIRWAYS. |
| | H. BIKE RACKS SHOULD BE AT THE FRONT OF THE BUILDING OR |
| | COMPLEX, NOT IN THE PARKING LOT FOR EASY SURVEILLANCE |
| | AND SAFETY. |
| | |
| | CAMERAS |
| | A. CCTV CAMERAS SHOULD BE LOCATED ON EACH FLOOR, |
| | MONITORING ACCESS POINTS, NURSING STATION, STAIRWELLS, |
| | LOBBY, ETC. |
| | B. THE MONITORING AND CONTROL OF THE CCTV CAMERAS SHALL |
| | BE AT A CENTRAL MONITORING OFFICE OR BOOTH. |
| | C. A HIGH-RESOLUTION COLOR DIGITAL VIDEO CAMERA SYSTEM |
| | WITH MONITORING AND PHOTO PROCESSING PRINTOUT |
| | CAPABILITIES SHALL BE USED. |
| | |
| | |
| | |
| |
Print |