Plan Review Notes
Plan Review Notes For Project Z10010005
Project Number Z10010005
Review Stop POLICE
Sequence Number 1
Notes
Date Text
2010-02-03 12:31:45 
 I HAVE NO COMMENT ON THE ADDITION, HOWEVER I STILL
 STAND BY THE COMMENTS FROM THE FIRST REVIEW AS NOTED
 BELOW
  
  
 CPTED REQUIREMENTS
  
 THE FOLLOWING SUGGESTIONS ARE MADE FOR THE PURPOSE OF
 REDUCING THE LIKELIHOOD OF CRIMINAL ACTIVITY. WHILE NO
 GUARANTEE CAN BE STATED OR IMPLIED, THE CONCEPTS OF
 CPTED HAVE PROVEN THEMSELVES INTERNATIONALLY. THE WEST
 PALM BEACH POLICE DEPARTMENT OFFERS THESE SUGGESTIONS
 AS A PUBLIC SERVICE, WITH THE UNDERSTANDING THAT THERE
 IS NO WAY TO PREDICT OR PREVENT ALL CRIME RISKS. THE
 PURPOSE OF THESE REQUIREMENTS IS TO REDUCE FORMABILITY
 OF CRIME, BY MAKING A GOOD FAITH EFFORT TO PROVIDE A
 SAFE ENVIRONMENT.
 BELOW IS A LIST OF CRIME PREVENTION RECOMMENDATIONS TO
 HELP DETER CRIMINAL ACTIVITY FOR COMMERCIAL BUILDINGS.
  
 COMMERCIAL:
 1. ALL LIGHTING SHALL BE METAL HALIDE FOLLOWING IESNA
 LIGHTING STANDARDS.
 2. LANDSCAPING SHALL NOT CONFLICT WITH LIGHTING (TO
 INCLUDE LONG-TERM TREE CANOPY GROWTH).
 3. TIMER CLOCK OR PHOTOCELL LIGHTING FOR NIGHTTIME USE
 SHALL BE ABOVE OR NEAR ENTRYWAYS.
 4. PEDESTRIAN SCALE LIGHTING SHALL BE USED FOR ALL
 STREET AND PEDESTRIAN WALKWAYS. IT IS SUGGESTED THAT
 INTERACTIVE OR LIGHTING ON DEMAND BE USED IN SENSITIVE
 AREAS.
 5. NUMERICAL ADDRESS:
 A SHOULD BE ILLUMINATED FOR NIGHTTIME VISIBILITY (DUSK
 TO DAWN).
 B SHOULD NOT BE OBSTRUCTED.
 C SHOULD HAVE BI-DIRECTIONAL VISIBILITY FROM THE
 ROADWAY.
 D DOOR NUMBER SHALL BE A MINIMUM OF 6???
 E BUILDING NUMBERS SHALL BE A MINIMUM OF 12???.
 6. LIGHTING SHOULD BE PROVIDED FOR ENTRANCE SIGNAGE.
 COMMERCIAL BUILDINGS:
 I BUILDING LIGHTING (NON-GLARE) SHOULD BE AROUND
 PERIMETER ON ALL SIDES AND ON PEDESTRIAN WALKWAYS.
 J ALL EXTERIOR DOORS SHOULD BE EQUIPPED WITH SECURITY
 HINGES AND SHOULD BE REINFORCED WITH CASE HARDENED
 STRIKE PLATE.
 K GLASS PERIMETER DOORS SHOULD BE EQUIPPED WITH CASE
 HARDENED GUARD RINGS TO PROTECT THE MORTISE LOCK
 CYLINDER.
 L REAR DOORS SHOULD BE EQUIPPED WITH 180-DEGREE
 PEEPHOLE VIEWER.
 M DUMPSTERS SHOULD NOT ALLOW FOR EASY CONCEALMENT, NOT
 CREATE BLIND SPOTS OR HIDING AREAS.
 N CROSSWALKS SHOULD BE RAISED AND DELINEATED BY USING
 CONTRASTING PAVER BLOCKS AS OPPOSED TO SURFACE
 STRIPPING.
 O SIGNS SHALL CLEARLY MARK PUBLIC ENTRANCES.
  J. BICYCLE SPACES SHOULD BE LOCATED IN CLOSE PROXIMITY
 TO THE FRONT OF BUILDINGS AND NOT IN PARKING LOTS.
  K. ROOFS OF COMMERCIAL BUILDINGS SHOULD HAVE THE
 NUMERICAL ADDRESS DISPLAYED SO THAT IT MAY BE SEEN BY
 AIR.
  
 PARKING GARAGE/STRUCTURES:
  
 ??? STAIRWELLS SHOULD BE VISIBLE WITHOUT SOLID WALLS.
 ??? ELEVATORS SHOULD BE CLOSE TO MAIN ENTRANCE
 CONSTRUCTED TO AVOID HIDDEN SPACES
 ??? LIGHTING WITHIN MULTI-LEVEL PARKING STRUCTURES IS
 MAINTAINED AT THE STANDARDS ESTABLISHED BY IESNA USING
 METAL HALIDE LIGHTING.
 ??? ROOFS OF GARAGE SHOULD BE PAINTED WHITE TO REFLECT
 LIGHT ON THE PARKING LEVELS.
 ??? PEDESTRIAN ENTRANCES SHOULD BE ADJACENT TO VEHICLE
 ENTRANCES OPEN AND FREE OF HIDDEN SPACES.
 ??? THERE SHOULD BE NO PERMANENT, STOP BUTTON IN
 ELEVATORS.
 ??? PUBLIC AND PRIVATE PARKING SPACES SHOULD BE
 DESIGNATED.
 ??? ALL WALLS AND SUPPORT STRUCTURES SHOULD BE
 CONSTRUCTED WITH OPEN SIDES TO AVOID CREATION OF HIDDEN
 SPACES.
 ??? LIGHTING SHOULD BE PLACED WHERE USERS REQUIRE
 LIGHTS: OVER VEHICLES.
 ??? LIGHTING FIXTURES SHOULD BE EXTENDED PAST THE BEAMS
 IN THE GARAGE CEILING
  
 MISCELLANEOUS:
  
 1. ANY STORAGE AREAS WITH EXTERIOR ROLL UP DOORS SHOULD
 BE TARGET HARDENED (IE: SECURED LOCKS, CONNECTED TO
 ALARM SYSTEM).
 2. ROLL UP ALUMINUM DOOR NEEDS TO BE TARGET-HARDEN.
  
  