| 2009-08-05 11:30:10 | INTERIOR: |
| | |
| | A. PLACE GLASS IN THE SEATING AREA FOR A CLEAR VIEW |
| | INTO THE SEATING AREA FROM THE RECEPTION DESK |
| | B. PLACE DOOR ACROSS THE HALLWAY LEADING INTO THE BACK |
| | PATIENT AREA. (ACROSS THE RECEPTION DESK, AFTER THE |
| | PATIENT RESTROOM.) |
| | C. PLACE A SWINGING TYPE DOOR ACROSS THE RECEPTION AREA |
| | ENTRY. |
| | D. HOW ARE YOU RESTRICTING ACESS INTO STAIRWELL LEADING |
| | TO THE SECOND FLOOR? |
| | |
| | NO LIGHTING IS SHOWN ON THE PLAN, THIS NEEDS TO BE |
| | SUBMITTED SO IT CAN BE CHECKED AGAINST THE LANSCAPE |
| | PLAN THAT WAS SUBMITTED. |
| | |
| | 3 COMMERCIAL SECURITY |
| | |
| | 3.1 LIGHTING |
| | A. PARKING LOT AND PEDESTRIAN LIGHTING SHALL BE: |
| | A) HIGH EFFICACY OF GREATER THAN 70 LUMENS PER WATT |
| | B) A KELVIN TEMPERATURE OF 3,500 K OR GREATER THAN |
| | KELVIN TEMPERATURE |
| | C) COLOR RENDERING INDEX (CRI) OF 70 OR GREATER |
| | D) LAMP LIFE OF 20 THOUSAND HOURS OR GREATER. |
| | B. LIGHT POLES 10 ??? 15 FOOT HIGH FOR PEDESTRIAN-SCALE |
| | LIGHTING SHALL BE USED FOR ALL PEDESTRIAN WALKWAYS. |
| | C. PARKING LOT LIGHTING SHALL USE 20 -25 FOOT POLES. |
| | D. LANDSCAPING SHALL NOT OBSTRUCT VIEW OF WINDOWS, |
| | BUILDING ADDRESS NUMBERS, LIGHTING AND WALKWAYS. |
| | E. TIMER CLOCK OR PHOTOCELL SENSOR-ENGAGED LIGHTING FOR |
| | ABOVE OR NEAR ENTRYWAYS TO BUILDINGS FOR DUSK TO DAWN |
| | OPERATION SHALL BE PROVIDED. |
| | F. ENTRANCE SIGN LIGHTING SHALL BE PROVIDED. |
| | G. BUILDING LIGHTING (NON-GLARE) SHALL BE AROUND |
| | PERIMETER ON ALL SIDE. |
| | |
| | 3.2 NUMERICAL ADDRESS |
| | A. ILLUMINATION FOR NIGHTTIME VISIBILITY IS REQUIRED. |
| | ADDRESS SHOULD BE PLACED UNDER A LIGHT FIXTURE OR BE |
| | BACK LIT. |
| | B. BI-DIRECTIONAL VISIBILITY FROM THE ROADWAY IS |
| | REQUIRED. |
| | C. ADDRESS NUMBERS ON SUITES/OFFICES WITHIN |
| | MULTI-TENANT BUILDINGS SHALL BE A MINIMUM OF 6 INCHES |
| | HIGH. |
| | D. BUILDING NUMBERS SHALL BE A MINIMUM OF 12 INCHES |
| | HIGH AND PLACED IN A CONSPICUOUS LOCATION AWAY FROM |
| | LANDSCAPING. MULTIPLE LOCATIONS MAY BE REQUIRED. |
| | NUMBERS OF CONTRASTING COLORS SHOULD BE USED. |
| | |
| | 3.3 DOORS |
| | A. EXTERIOR DOORS SHALL ALL BE EQUIPPED WITH SECURITY |
| | HINGES AND SHALL BE REINFORCED WITH CASE HARDENED |
| | STRIKE PLATES. CASE HARDENED DEADBOLT LOCKS SHALL BE |
| | PROVIDED ON ALL EXTERIOR DOORS WITH A MINIMUM (1) INCH |
| | THROW OR MECHANICAL INTERLOCK. |
| | B. GLASS PERIMETER DOORS SHALL BE EQUIPPED WITH CASE |
| | HARDENED GUARD RINGS TO PROTECT THE MORTISE LOCK |
| | CYLINDER. |
| | C. REAR DOORS SHALL BE EQUIPPED WITH 180-DEGREE |
| | PEEPHOLE/ SECURITY VIEWER. |
| | |
| | 3.5 DESIGN |
| | A. BUILDING ARCHITECTURE SHALL ALLOW FOR ENHANCED |
| | NATURAL SURVEILLANCE OF ALL PARKING LOTS AND PROVIDE A |
| | SENSE OF SECURITY TO PATRONS AND VISITORS. |
| | B. LANDSCAPING SHALL NOT OBSTRUCT VIEW FROM WINDOWS OR |
| | WALKWAYS. |
| | C. ALL BUILDINGS SHALL BE PRE-WIRED FOR CLOSED-CIRCUIT |
| | TELEVISION (CCTV) AND ALARM SYSTEMS. |
| | D. DUMPSTERS SHALL NOT ALLOW FOR EASY CONCEALMENT, |
| | CREATE BLIND SPOTS OR HIDING AREAS AND SHOULD BE ABLE |
| | TO BE LOCKED. |
| | E. SIGNS SHALL CLEARLY IDENTIFY PUBLIC ENTRANCES. |
| | F. LANDSCAPING SHALL BE MAINTAINED AT 3 FEET OR LESS. |
| | TREES SHALL BE INSTALLED SO AS NOT TO CONFLICT WITH THE |
| | LIGHTING SYSTEM. LOWER CANOPY LIMBS ON TREES SHALL BE |
| | MAINTAINED AT 8 FEET OR HIGHER. |
| | G. CONVEX MIRRORS SHALL BE INSTALLED IN STAIRWELL |
| | ENABLING VIEWS OF UPPER AND LOWER STAIRWAYS. |
| | H. BIKE RACKS SHOULD BE AT THE FRONT OF THE BUILDING OR |
| | COMPLEX, NOT IN THE PARKING LOT FOR EASY SURVEILLANCE |
| | AND SAFETY. |
| | |
| |