| 2009-08-05 10:40:58 | IN ADDITION TO ADHERING TO THE CITY ORDINANCE, |
| | |
| | * WINDOWS NEED TO BE ADDED ON THE EAST SIDE OF THE |
| | STORE TO VIEW CAR WASH AREA |
| | * CAMERA PLACEMENT WAS NOT ON THE PLAN, BUT AREAS THAT |
| | WILL NEED TO BE COVERED ARE: REAR OF STORE, CAR WASH |
| | ENTRY, FRONT DOOR, SIDES OF STORE, RESTROOM AREA, |
| | CASHIER AREA, GAS PUMP AREA |
| | * LIGHTING IN THE REAR OF THE STORE, WALL PACKS NOT |
| | SHOWN ON PLAN FOR THE BUILDING |
| | * MIRROR THE ENTRY TO CAR WASH TO GIVE USER VIEW BEHIND |
| | THEM |
| | * PEEP HOLE IN OFFICE DOOR, UTILITY AREA AND REAR DOOR |
| | * PASS THROUGH DRAWER IS NOTED ON PLAN, HOWEVER BULLET |
| | RESISTANT ENCLOSURE WILL BE NEEDED AROUND CASHIER AREA. |
| | |
| | ADDITIONAL COMMENTS WILL BE SUBMITTED WHEN A TENANT |
| | SUBMITS THE ACTUAL PLAN FOR THE PROPOSED STORE. DUE TO |
| | THE AREA THIS WILL BE CONSIDERED A HIGH RISK STORE, |
| | ADDITIONAL SECURITY MEASURES WILL BE REQUIRED. |
| | |
| | |
| | |
| | |
| | CONVENIENCE STORES/GAS STATIONS |
| | LIGHTING |
| | A. PARKING LOT AND PEDESTRIAN LIGHTING SHALL BE: |
| | A) HIGH EFFICACY OF GREATER THAN 70 LUMENS PER WATT |
| | B) A KELVIN TEMPERATURE OF 3,500 K OR GREATER THAN |
| | KELVIN TEMPERATURE |
| | C) COLOR RENDERING INDEX (CRI) OF 70 OR GREATER |
| | D) LAMP LIFE OF 20 THOUSAND HOURS OR GREATER. |
| | B. LIGHT POLES 10 ??? 15 FOOT HIGH FOR PEDESTRIAN-SCALE |
| | LIGHTING SHALL BE USED FOR ALL PEDESTRIAN WALKWAYS. |
| | C. PARKING LOT LIGHTING SHALL USE 20 -25 FOOT POLES. |
| | D. LANDSCAPING SHALL NOT OBSTRUCT VIEW OF WINDOWS, |
| | BUILDING ADDRESS NUMBERS, LIGHTING AND |
| | WALKWAYS. |
| | E. PROVIDE TIMER CLOCK OR PHOTOCELL SENSOR ENGAGED |
| | LIGHTING FOR ABOVE OR NEAR ENTRYWAYS AND ALL PEDESTRIAN |
| | SIDEWALKS FOR DUSK TO DAWN OPERATION. |
| | F. PROVIDE LIGHTING FOR ENTRANCE SIGN. |
| | G. LIGHTING ON BUILDINGS SHALL BE AROUND PERIMETER OF |
| | ALL SIDES AND ON PEDESTRIAN WALKWAY SURROUNDING THE |
| | BUILDINGS. |
| | NUMERICAL ADDRESS |
| | A. ILLUMINATION FOR NIGHTTIME VISIBILITY IS REQUIRED. |
| | B. BI-DIRECTIONAL VISIBILITY FROM THE ROADWAY IS |
| | REQUIRED. |
| | C. ADDRESS NUMBERS ON DOORS SHALL BE A MINIMUM OF 6 |
| | INCHES HIGH. |
| | DESIGN |
| | A. CONVEX MIRRORS SHALL BE INSTALLED AND SIGNS AND |
| | SHELVES SHALL BE KEPT LOW, WHERE THEY DON???T OBSTRUCT |
| | EMPLOYEE VIEW. |
| | B. DROP SAFE SHALL BE INSTALLED. |
| | C. SIGNAGE INDICATING THAT LITTLE CASH IS KEPT ON HAND |
| | SHALL BE VISIBLE. |
| | D. VIDEO SURVEILLANCE EQUIPMENT AND CCTV TO DETER |
| | ROBBERIES SHALL BE INSTALLED, THEREBY INCREASING THE |
| | RISK OF IDENTIFICATION. CCTV SHOULD BE INSTALLED TO |
| | OBSERVE THE PUMP TRANSACTIONS, RECORD ACTIVITIES AND |
| | TRANSACTIONS OF A CLERK, FRONT AND REAR DOOR, COVER |
| | HARD TO SEE AREAS, CAR WASH, BATHROOMS, TIRE/WATER |
| | PUMPS, TELEPHONES AND ATMS. |
| | E. SILENT ALARMS TO NOTIFY POLICE IN THE EVENT OF A |
| | PROBLEM SHALL BE INSTALLED. |
| | F. DOORS NOT IN USE SHALL BE KEPT LOCKED. |
| | G. REAR DELIVERY DOORS SHALL HAVE A PEEPHOLE, DOOR |
| | CHIME DETECTOR AND LOCKING MECHANISM ON THE DOOR THAT |
| | ONLY FUNCTIONS WITH A KEY. |
| | H. STORE ACCESS DURING LATE NIGHT HOURS SHALL BE |
| | LIMITED BY INSTALLING BULLET-RESISTANT ENCLOSURES WITH |
| | PASS-THROUGH WINDOWS. |
| | I. EXIT DOORS SHALL HAVE HEIGHT MARKERS TO HELP |
| | WITNESSES PROVIDE MORE COMPLETE DESCRIPTIONS OF |
| | ASSAILANTS. |
| | J. DOOR CHIME DETECTORS TO ALERT EMPLOYEES WHEN PERSONS |
| | ENTER THE STORE SHALL BE INSTALLED. |
| | K. STORE ACCESS SHALL BE CONTROLLED WITH DOOR BUZZERS |
| | FOR NIGHTTIME USE OR CLOSING HOURS. |
| | L. BATHROOMS SHALL BE LOCATED IN A CONSPICUOUS LOCATION |
| | WHERE THERE WILL BE A HIGH VOLUME OF PEDESTRIAN |
| | TRAFFIC. KEY CONTROL SHOULD BE USED FOR ACCESS. |
| | M. CASHIER STATION AREA SHALL BE PLACED AT THE FRONT OF |
| | THE STORE FOR GOOD VISIBILITY AND ENHANCED NATURAL |
| | SURVEILLANCE. |
| | N. STORAGE AREAS WITH EXTERIOR ROLL-UP DOORS SHALL BE |
| | TARGET HARDENED (I.E., SECURED LOCKS CONNECTED TO ALARM |
| | SYSTEM). |
| | O. FUEL TANKS AND FUEL PUMPS SHALL BE PLACED IN AN |
| | ISOLATED AREA OF THE PARKING LOT AWAY FROM BUILDINGS |
| | AND FLOW OF PARKING LOT TRAFFIC. FUEL TANKS AND FUELS |
| | PUMPS SHALL BE SECURED AREAS (NOT EASILY ACCESSIBLE). |
| | P. ATM INSTALLATION SHALL MEET FSS 655-965 |
| | REQUIREMENTS. |
| | Q. ATM SHOULD BE LOCATED WITHIN SIGHT OF CASHIER. |
| | R. AVOID PLACEMENT OF ATM BY THE ENTRANCE OF THE STORE. |
| | S. THE INSTALLATION OF THE ATM SHOULD BE PHYSICALLY |
| | ATTACHED TO THE FLOOR. |
| | |
| | |
| | |
| |
Print |