| Date |
Text |
| 2020-05-05 07:56:47 | FOLLOWING COMMENT FROM RICK ROSSANO, PROJECT |
| | COORDINATOR, ENGINEERING SERVICES: |
| | PLEASE UPDATE DUMPSTER ENCLOSURE DIMENSIONS ON SHEET |
| | C6.1 TO COMPLY WITH CURRENT CITY OF WPB STANDARD DETAIL |
| | GC-7, AND ADD DETAIL GC-7 TO DETAIL SHEET. |
| | |
| | FOLLOWING COMMENTS ARE FROM MARK HURLEY, FIELD CUSTOMER |
| | SERVICE SUPERVISOR, CITY OF WEST PALM BEACH PUBLIC |
| | UTILITIES, [email protected] , 561-822-2262: |
| | -DEMOLITION PLAN SAYS THAT ABANDONED WATER MAIN WILL BE |
| | REMOVED OR GROUTED. THAT SEEMS LIKE IT WOULD BE |
| | CONFUSING FOR CONSTRUCTION TEAM. PLAN SHOULD GIVE MORE |
| | GUIDANCE ON HOW THAT IS DETERMINED, OR PICK ONE OPTION. |
| | |
| | -PLEASE ADD NOTE FOR REMOVED WATER METERS ON DEMO PLAN: |
| | RETURN METER TO CITY WPB 561-822-2262 |
| | |
| | -ON UTILITY PLAN, THE IRRIGATION BACKFLOW ASSEMBLY |
| | CANNOT BE LOCATED WITHIN THE UTILITY EASEMENT. THE |
| | SERVICE LINE SIZE AND MATERIAL TYPE SHOULD ALSO BE |
| | LABELED. |
| | |
| | -ON UTILITY PLAN, ON 27TH ST. THE NOTE IS TO CONNECT 2 |
| | IN. WATER MAIN ON NORTH SIDE TO NEW 8 IN. MAIN. I |
| | THOUGHT THE INTENT WAS TO CONNECT THE EXISTING 2 IN. |
| | WATER MAIN TO THE SOUTH TO THE NEW 8 IN. MAIN ? PLEASE |
| | VERIFY. |
| | |
| | -ON UTILITY PLAN, FOOTPRINT FOR THE 3 IN. METER WITH |
| | WATER SERVICE LOOKS LIKE IT MAY BE DRAWN SMALLER THAN |
| | IT ACTUALLY IS WHEN BUILT. METER LABEL SHOULD REFERENCE |
| | STANDARD DETAIL WS-8 (ABOVE-GROUND METER). |
| | |
| | -UTILITY PLAN DOES NOT SHOW SHUT-OFF GATE VALVE FOR 8? |
| | EXISTING WATER MAIN ON 27TH AT BROADWAY LIKE IT DOES ON |
| | 28TH ST ? PLEASE ADD TO PLAN. |
| | |
| | -HARD TO FIND THE ADDRESS OF THE PROPERTY ON THE PLAN. |
| | PLEASE ADD TO SIDE-BAR. |
| | |
| | -FLOW CALCULATIONS ONLY SHOW BEDROOMS. WILL THERE BE |
| | ANY FLOW FOR THE MAINTENANCE OR COMMERCIAL BUILDINGS |
| | |
| | -LOOKS LIKE THERE MAY BE EXISTING WATER SERVICES IN |
| | ALLEY FOR 611 27TH ST AT NORTH SIDE OF PROPERTY. PLEASE |
| | REMOVE SERVICE LINE IF REMOVING WATER MAIN. |
| | |
| | -METER BOX AND LID INSTALLED IN MIDDLE OF ALLEY |
| | PAVEMENT WOULD NEED TO BE TIER 22 RATED. IT NEEDS TO BE |
| | AT LEAST SEVERAL FEET AWAY FROM MANHOLE. |
| | |
| | FEEL FREE TO CONTACT US IF YOU HAVE ANY QUESTIONS OR |
| | CONCERNS, THANKS. |
| | |
| | RICK ROSSANO, PROJECT COORDINATOR, ENGINEERING SERVICES |
| | DEPARTMENT |
| | (561) 494-1098 [email protected] |
| | |
| | |
| |
Print |