| 2018-01-24 13:23:03 | CANOPY HOTEL, E16100001 |
| | ADDRESS: 704-718 S. DIXIE HWY |
| | STATUS: FAILED |
| | |
| | COMMENTS (PLEASE RESPOND TO COMMENTS IN WRITING): |
| | 1. SHOW PROFILE FOR PROPOSED WATER MAIN SHOULD INCLUDE |
| | VERTICAL CLEARANCES BETWEEN WATER AND OTHER UTILITIES; |
| | |
| | 2. REPLACE EXISTING 8-INCH DIAMETER (NOT 10-INCH |
| | DIAMETER AS SHOWN IN THE PLANS) SANITARY SEWER MAIN |
| | FROM MANHOLE TO MANHOLE TO A 12-INCH DIAMETER SDR-26 |
| | SANITARY SEWER. THE CURRENT CONDITION OF THE EXISTING |
| | PIPE IS AT HALF CAPACITY AND MAY NOT WITHSTAND THE |
| | PROPOSED DEMAND; |
| | |
| | 3. CCTV/DVD MUST BE PROVIDED BY DEVELOPER OF VIDEO OF |
| | SEWER MAIN TRINITY PL. TO BETTER ASSESS THE CONDITION |
| | OF THE EXISTING SYSTEM. WE SHOW INCONSISTENCY ON THE |
| | DIAMETER SIZE AND MATERIALS TYPE IN OUR AS-BUILTS AND |
| | FEEL THE DEVELOPER SHOULD VERIFY. OUR RECORDS INDICATE |
| | ASSET NUMBERS FOR THESE SEWER ELEMENTS DESCRIBED FROM |
| | WEST TO EAST: ASSET# SSMH6551, ASSET# SEWER LINE 07703, |
| | ASSET# SSMH0374. CHARLES PHOENIX, OF CITY O&M GROUP CAN |
| | BE CONTACTED TO COORDINATE THE ACCESS TO SANITARY |
| | SYSTEM. PLEASE ALLOW 48 HOUR NOTICE TO |
| | [email protected]. SUBMIT CD TO ENGINEERING SERVICES |
| | DEPARTMENT; |
| | |
| | 4. NEED TO SHOW THE VERTICAL CLEARANCE AT ALL UTILITY |
| | CROSSINGS THERE ARE MISSING CONFLICT INFORMATION WHERE |
| | SERVICES ENTER THE SITE; |
| | |
| | 5. WATER VALVE BOXES SHOULD NOT LAND WITHIN THE CURB |
| | RAMPS; |
| | |
| | 6. WILL THE PROXIMITY AND HORIZONTAL DISTANCE BETWEEN |
| | THE PROPOSED AND EXISTING WATER MAIN BE A PROBLEM |
| | DURING CONSTRUCTION? CITY OF WPB PUBLIC UTILITIES |
| | DEPARTMENT WOULD LIKE A BRIEF SUMMARY RESPONSE OF MEANS |
| | AND METHOD FOR THIS INSTALLATION; |
| | |
| | 7. PLEASE ADD STANDARD DETAIL WS-6. CITY'S STANDARD |
| | DETAILS (IN PDF FILE FORMAT) CAN BE DOWNLOADED FROM THE |
| | FOLLOWING SITE: HTTP://WPB.ORG/DEPARTMENTS/ENGINEERING- |
| | PUBLIC-WORKS/FORMS,-PERMITS-APPLICATIONS |
| | |
| | 8. DEDICATED FIRELINE SERVING 700 S DIXIE DOES NOT |
| | SHOWN ON PLANS. PLEASE SHOW CONNECTION TO THE PROPOSED |
| | WM; |
| | |
| | SOFIA QUINONES-BENEJAM, EI |
| | PROJECT ENGINEER |
| | CITY OF WEST PALM BEACH |
| | 401 CLEMATIS STREET, 4TH FLOOR |
| | WEST PALM BEACH, FL 33401 |
| | P: 561.494.1040 EXT: 1108 |
| | C: 561.459.6518 |
| | F: 561.494.1116 |
| | EMAIL: [email protected] |
| | |
| |