| 2016-10-26 13:10:20 | COMMENTS FOR THE CANOPY HOTEL PROJECT LOCATED AT |
| | 704-718 S. DIXIE HWY.: |
| | |
| | THE FOLLOWING COMMENTS MUST BE ADDRESSED PRIOR TO |
| | ISSUANCE OF CONSTRUCTION AUTHORIZATION INCLUDING |
| | BUILDING PERMITS AND ENGINEERING DEVELOPMENT APPROVAL. |
| | |
| | 1. AN ENGINEERING DEVELOPMENT APPROVAL APPLICATION WILL |
| | NEED TO BE SUBMITTED TO THE ENGINEERING DIVISION OF THE |
| | PUBLIC WORKS DEPARTMENT. THE ENGINEERING DEVELOPMENT |
| | APPROVAL APPLICATION FORMS CAN BE DOWNLOADED AT: |
| | HTTP://WPB.ORG/DEPARTMENTS/ENGINEERING-PUBLIC-WORKS/FOR |
| | MS,-PERMITS-APPLICATIONS |
| | |
| | 2. PLEASE SUBMIT THE LATEST VERSION OF THE ?AUTO-CALC |
| | CERTIFIED COST ESTIMATE FORM? FOR SUBMISSION TO CITY OF |
| | WEST PALM BEACH PUBLIC WORKS DEPARTMENT. THIS FORM CAN |
| | BE DOWNLOADED FROM THE FOLLOWING LINK: |
| | HTTP://WPB.ORG/DEPARTMENTS/ENGINEERING-PUBLIC-WORKS/FOR |
| | MS,-PERMITS-APPLICATIONS |
| | |
| | 3. PLEASE SUBMIT A COPY OF THE ALTA/ACSM SURVEY WHICH |
| | HAS BEEN SIGNED AND SEALED BY PROFESSIONAL SURVEY & |
| | MAPPER (PSM). |
| | |
| | 4. PLEASE PROVIDE SOLID WASTE COLLECTION YARDAGE AND |
| | SANITATION/GARBAGE COLLECTION PLANS FOR THE |
| | DEVELOPMENT. SITE PLAN DOES NOT SHOW ANY GARBAGE |
| | RECEPTACLE/DUMPSTER. |
| | |
| | 5. COMMENTS ON DRAINAGE/STORMWATER MANAGEMENT PLANS ARE |
| | BEING REVIEWED BY THE CITY?S STORMWATER ENGINEER, TRACY |
| | WARD, P.E. AND WILL BE PROVIDED SOON. |
| | |
| | |
| | FOLLOWING ARE THE COMMENTS ON WATER AND SEWER PLANS |
| | (SHEET C-11, C-12 AND C-13): |
| | |
| | 1. PLEASE ADD PROPERTY LINES ON WATER, SEWER AND |
| | UTILITY PLAN SHEET C-11. PLACEMENT OF THE PROPOSED |
| | METER, BACKFLOW PREVENTER, DCDA ETC. SHALL BE INSTALLED |
| | PER THE CITY?S STANDARD DETAILS; |
| | |
| | 2. PLEASE SUBMIT WATER AND SEWER DEMAND CALCULATIONS |
| | (AVERAGE AND PEAK) FOR METER SIZING SELECTION AND |
| | SERVICE SIZING SIGNED & SEALED BY ENGINEER/MEP. PLEASE |
| | ALSO PROVIDE CALCULATION FOR FIRE FLOW DEMAND; |
| | |
| | 3. PLEASE INCLUDE THE LATEST VERSION OF THE CITY OF |
| | WEST PALM BEACH STANDARD WATER AND SEWER DETAILS TO THE |
| | CWPB UTILITY NOTES PLAN SHEET C-12. CONTACT THE |
| | ENGINEERING SERVICES DEPARTMENT (561) 494-1040 FOR THE |
| | LATEST REVISED DETAILS. |
| | 4. EXISTING UTILITY SERVICE LINES, IF NOT USED BY THE |
| | SITE REDEVELOPMENT, ARE TO BE CUT AND CAPPED AT THE |
| | MAIN AND REMOVED IF LARGER THAN 2 INCHES IN DIAMETER. |
| | PLEASE ADD THE APPROPRIATE NOTES ON THE WATER & |
| | WASTEWATER PLAN; |
| | |
| | 5. PLEASE PROVIDE THE FIRE HYDRANT FLOW TEST DATA FROM |
| | EXISTING FIRE HYDRANT USED FOR DESIGN; |
| | |
| | 6. THE CITY WILL PROVIDE CCTV RECORD OF THE EXISTING |
| | SANITARY SEWER MAIN ON TRINITY PLACE. EXISTING PIPE |
| | DIAMETER, PIPE MATERIAL, INVERT ELEVATION, ETC., ARE TO |
| | BE CONFIRMED BY THE ENGINEER; |
| | |
| | 7. PLEASE PERFORM SOFT DIGS AND PROVIDE UTILITY |
| | CROSSING INFORMATION; |
| | |
| | 8. PLEASE LABEL EXISTING UTILITY PIPE SIZE AND |
| | MATERIAL; |
| | |
| | 9. PLEASE CALL OUT POINT OF SERVICE FOR WATER AND SEWER |
| | ON THE UTILITY PLANS; |
| | |
| | 10. PLEASE SHOW EXISTING WATER DISTRIBUTION SYSTEM |
| | INCLUDING CONNECTIONS TO SIDE STREETS AND VALVES FOR |
| | CONSTRUCTION COORDINATION PURPOSES (SYSTEM SHUTDOWNS, |
| | ETC.); |
| | |
| | 11. PLEASE SHOW UNIT COUNT/TYPE OF BUILDING/SQUARE |
| | FOOTAGE FOR WATER/SEWER CAPACITY DETERMINATION ON |
| | UTILITY PLAN; |
| | |
| | 12. PLEASE INCLUDE APPLICABLE CITY OF WEST PALM BEACH |
| | STANDARD WATER AND SEWER DETAILS TO THE DETAILS SHEET. |
| | CONTACT THE ENGINEERING SERVICES DEPARTMENT (561) |
| | 494-1040 FOR THE LATEST REVISED DETAILS; |
| | |
| | 13. PLEASE PROVIDE UTILITY CROSSING INFORMATION; |
| | |
| | 14. PLEASE PROVIDE FIRE HYDRANT FLOW TEST DATA FROM |
| | EXISTING FIRE HYDRANT ON S DIXIE HWY; |
| | |
| | 15. EXISTING WATER SERVICE CONNECTIONS SERVING THE |
| | PROPERTY, IF NOT USED, ARE TO BE CUT AND CAPPED AT THE |
| | MAIN. DE-ACTIVATED/INACTIVE PIPELINES LARGER THAN 2" |
| | DIAMETER WILL BE REMOVED. PLEASE LABEL PIPE SIZE AND |
| | MATERIAL AND ADD NOTES TO THE UTILITY PLANS |
| | ACCORDINGLY; |
| | |
| | 16. EXISTING SEWER SERVICE CONNECTIONS SERVING THE |
| | PROPERTY, IF NOT USED, ARE TO BE CUT AND CAP AT THE |
| | MAIN. PLEASE LABEL PIPE SIZE AND MATERIAL AND ADD NOTES |
| | TO THE UTILITY PLAN ACCORDINGLY; |
| | |
| | 17. THE CITY IS EVALUATING IMPACTS TO THE WATER AND |
| | SEWER SYSTEMS DUE TO INCREASED DEMAND; |
| | |
| | 18. REFER TO THE CITY' STANDARD DETAILS FOR PLACEMENT |
| | OF PROPOSED DDCV, BACKFLOW PREVENTER ASSEMBLY, METER |
| | VAULT/BOX, AND CLEAN-OUT; |
| | 19. PLEASE PROVIDE ENGINEERING/MEP CALCULATION FOR THE |
| | PROPOSED 12? WM SIZING ON TRINITY PLACE; |
| | |
| | 20. PROPOSED FIRE DEPARTMENT CONNECTION (FDC) SHOULD BE |
| | ACCESSIBLE TO HYDRANT (WITHIN 150 FEET); |
| | |
| | 21. IT IS THE CITY'S PREFERENCE NOT TO HAVE PARALLEL |
| | WATER MAINS IN THE SYSTEM. REMOVE THE EXISTING 8" WM |
| | AND INSTALL THE NEW 12" WM WITH 36" MINIMUM COVER IN |
| | THE SAME LOCATION. PROVIDE CONNECTION TO ALL EXISTING |
| | SERVICES. ADD THE WM PROFILE ON 1"-20' SCALE; |
| | |
| | 22. ASBUILTS FOR 700 S DIXIE HWY.; 309-353 TRINITY |
| | PLACE; SOUTH DIXIE HWY. FROM JUST NORTH OF TANGLEWOOD |
| | CT. TO JUST OF SOUTH OF TRINITY PLACE; AND TWO CITY |
| | PLAZA AT 701 S OLIVE AVE. ARE PROVIDED. CALL OUT THE |
| | SIZE, PIPE CONFIGURATION, METER SIZE, ETC. FOR ALL THE |
| | EXISTING SERVICE CONNECTIONS; |
| | |
| | 23. THE PROPOSED WM CONNECTION AT S. DIXIE HWY AND |
| | TRINITY PLACE NEEDS TO BE REVIEWED. INSTALL 12" TEE |
| | CUT-IN TEE IN LIEU OF TAPPING SLEEVE WHEREVER POSSIBLE; |
| | |
| | 24. PLEASE CALL OUT THE POINT OF SERVICE (SEWER). CCTV |
| | RECORD (VIDEO AND TV LOG) OF THE PROPOSED SAN SEWER |
| | MAIN WITHIN THE ROADWAY R/W WILL BE REQUIRED AS PART OF |
| | THE PROJECT CLOSE-OUT SUBMITTAL; |
| | |
| |