2014-05-07 14:36:25COMMENTS:
 #1 WATERLINE ON-SITE WILL BE CONSIDERED PRIVATE. SHEET
 C-5 SHOWS MARKUP AS HOW FIRE AND DOMESTIC SERVICE MUST
 ENTER SITE. FIRE LOOP WILL REQUIRE DCDA AT EACH POINT
 OF SERVICE CONNECTION.
 #2 THE EASEMENT ON-SITE WILL NOT BE REQUIRED.
 #3 SEWER SERVICE IN THE ALLEY RUNNING SOUTH EAST WILL
 NOT BE NEEDED. IT WILL NEED TO BE PLUGGED AT THE
 MANHOLE. IF MANHOLE IS AS BRICK TYPE MANHOLE; THE
 CONTRACTOR MUST REPLACE THE MANHOLE.
 #4 PROVIDE ALLEYWAY CONDITION SUMMARY AND ENGINEER
 OPINION AS TO THE NEED OF DRAINAGE AND RESURFACE.
 #5 PROVIDE ADA ACCESS AND TRUNCATED DOMES AT ALLEYWAY
 AT CHILLINGSWORTH DRIVE INTERSECTION.
 #6 DRIVEWAY ACCESS APRONS (THE APPROACH) MUST BE OF
 CONCRETE MATERIAL, 6IN. THICK AS PER CITY OF WPB
 STANDARD DETAIL. THESE MUST ALSO INCORPORATE VALLEY
 CURB TO ALLOW DRAINAGE FLOW THRU.
 #7 CALL OUT GREASE SEPARATOR SIZE AND MATERIAL.
 #8 COMPACTOR FENCE MUST CLEAR ALLEYWAY.
 #9 PROVIDE DRAINAGE FLOW THRU EASEMENT THRU FPL
 PROPERTY.
 #10 FUTURE FUEL TANK SHOULD NOT BE SHOWN IF NOT BEING
 PERMITTED. IT CONFLICTS OVER THE EXISTING STORM LINE.
 #11 EXIST. MH2 WILL NEED REPLACEMENT IF NOT FOUND TO BE
 SEALED OR REHABILITATED. THE ADJUSTMENT OF THE RING AND
 COVER IS 2.5 FEET APPROXIMATELY.
 #12 WORK ALONG OKEECHOBEE BLVD WILL REQUIRE AND FDOT
 PERMIT. SIGNAGE INTERACTING TO FDOT ROADS MUST MEET
 FDOT SPECIFICATIONS, THIS WILL INCLUDE STRIPING FOR
 CHILLINGSWORTH DRIVE.
 #13 PROVIDE MORE DETAIL ON THE STRIPING OF
 CHILLINGSWORTH DRIVE STRIPING.
 #14 EXISTING WATER SERVICE SHALL BE SHOWN ON C-5 SHEET,
 PROVIDE LOCATION, SIZE AND FOR WHAT PURPOSE WILL IT
 NEED TO REMAIN. IF NOT USED IT MUST BE SHOWN TO BE CUT
 BACK AT MAIN.
 #15 VERIFY WATERMAIN SIZE ON CHILLINGSWORTH; 8 INCH
 DIAMETER WATERMAIN WAS INSTALLED AND IT?S NOT A 6INCH
 DIAMETER WATERMAIN.
 #16 SHEET C-4 SHOWS SECTION B-B (IT DOES NOT REFERENCE
 WHICH SHEET THE SECTION IS SHOWN) SHEET C-12 SECTION
 B-B SHOES NOT MATCH FEATURES ON C-4 (NO D-CURB SHOWN)
 IT?S ALSO SHOWN AT 30/3
 #17 A CITY HYDRANT MAY BE REQUIRED AT CHILLINGSWORTH
 100 FEET AWAY FROM ANY FDC. THIS WOULD REQUIRE A TAP.
 #18 DOORS OPENING AT NORTH END OF NORTHERN MOST
 BUILDING OPEN OUT TO TRAFFIC. SUGGEST INSTALLING
 BOLLARDS.
 #19 NO IRRIGATION WATER METER SHOWN.
 #20 NOTES REFERENCE THE VILLAGE OF WELLINGTON.
 #21 SIDEWALK DETAIL ON CHILLINGSWORTH MUST BE AS PER
 CITY OF WPB DETAIL.
 #22 HANDI CAP DETAIL SHOWS 18IN. DIMENSION FROM 4IN. TO
 4IN. STRIPE OUTSIDE DIMENSION (THIS MUST BE 20 INCH)
 #23 CITY FIRE HYDRANT DETAIL NOT SHOWN. FIRE HYDRANTS
 MUST BE PER CITY OF WPB SPEC.
 #24 CITY STORM WATER STANDARD DETAILS SHOWN ARE FOR USE
 IN THE ROW.
 #25 MILL AND OVERLAY OF THE ALLEY TO BE 1IN. THICK
 ASPHALT MINIMUM.
 #26 SUBMIT NPDES NOTICE.
 #27 PLEASE RESPOND TO COMMENTS IN WRITING.
  
  
  
  
  
  Print


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved