Plan Review Notes
Plan Review Notes For Project E13030023
Project Number E13030023
Review Stop ENG-A
Sequence Number 1
Notes
Date Text
2013-05-31 15:31:38PASSED WITH PROVISOS:
  
 #1 NOTED ON PLANS IS A 4" PVC FM LINE THAT CROSSES
 WATERMAIN,
 OBTAIN PROPER VERTICAL COVERAGE AND PROVIDE CONFLICT
 ELEVATIONS ON AS-BUILTS.
  
 #2 DATUM MUST BE NGVD 29 FOR AS-BUILTS.
  
 #3 DO NOT USE 6" TAPP, USE INSTEAD VALVE CUT-IN METHOD
 USING A 6" X 6" TEE.
  