Plan Review Notes
Plan Review Notes For Project E12080024
Project Number E12080024
Review Stop Z
Sequence Number 1
Notes
Date Text
2012-11-26 11:04:36FAILED
  
 1) PROVIDE DIMENSION LINES ON THE PAVING PLAN FOR THE
 ENTIRE LENGTH OF EACH PARKING BAY, THE DRIVEWAY
 CONNECTIONS, THE DRIVE AILSES AND THE LOADING AREAS TO
 ENSURE THAT THE CURBS ARE POURED IN THE CORRECT
 LOCATIONS.
  
 2) THE PARKING STALL DETAIL INCORRECTLY SHOWS REGULAR
 PARKING SPACES AT A MINIMUM OF EIGHT (8) FEET IN WIDTH,
 YET WEST PALM BEACH REQUIRES SPACES TO BE A MINIMUM OF
 8.5 FEET IN WIDTH (PARKING SPACES ON PLAN SCALE AT 8.5
 FEET WIDE).
  
 3) THE PARKING STALL DETAIL ALSO FAILS TO SHOW A WHEEL
 STOP FOR THE REGULAR PARKING SPACE, WHICH WILL BE
 REQUIRED TO PROTECT THE LANDSCAPE AT THE HEAD OF THE
 SPACES IN THE TWO OUTER PARKING ROWS.
  
 4) A SEPARATE STRIPING PERMIT WILL BE REQUIRED TO BE
 SUBMITTED TO THE CITY'S BUILDING DEPARTMENT.
  
 CONTACT ERIC SCHNEIDER @ (561) 822-1446.