| Date |
Text |
| 2010-07-07 13:22:03 | COMMENTS: |
| | |
| | #1 EXISTING AND PROPOSED BUILDINGS WHICH HAVE PLUMBING |
| | DRAIN OUTLETS AT AN ELEVATION 12" OR LESS ABOVE THE |
| | GROUND SURFACE OF THE NEXT UPSTREAM MANHOLE, WHERE THE |
| | ELEVATION OF ANY FLOOR IS AT OR BELOW THE INVERT OF THE |
| | ADJACENT CITY SANITARY SEWER MAIN OR IS LESS THAN 12" |
| | ABOVE THE GROUND SURFACE OF THE NEXT UPSTREAM MANHOLE, |
| | OR WHERE A CONDITION EXISTS WHERE A PLUG IN THE CITY |
| | SANITARY SEWER MAIN WILL CAUSE THE HYDRAULIC GRADIENT |
| | TO RISE ABOVE THE LOWEST FLOOR LEVEL. |
| | YOUR FFE 19.00 AND YOUR PROPOSED MANHOLE IS 18.30 |
| | SHOULD HAVE 12" CLERANCE MIN. |
| | |
| | #2 PROVIDE FFE AND CALL OUT EACH BUILDING ON SHEET C-3. |
| | |
| | #3 PROVIDE DIAMETER OF PROPOSED MANHOLE (4'DIA MIN) |
| | WITH 24" ACCESS OR REFERENCE MANHOLE DETAIL ON C-5. |
| | |
| | #4 LABEL CONDUIT COMING FROM SMALL BUILDING TO LARGE |
| | BUILDING (33' LONG) |
| | |
| | #5 PROVIDE FIRE HYDRANT OUT ON HAVERHILL ROAD TO SERVE |
| | FDC; FDC PLACEMENT SHOULD BE CLOSER TO ENTRANCE OF |
| | BUILDING WHERE FIRE DEPARTMENT COULD HAVE EASIER |
| | ACCESS. |
| | |
| | #6 PROVIDE WIDTH AND HEIGHT OF ENTRANCE COVERED AREA. |
| | IT MUST CLEAR EMERGENCY VEHICLES. |
| | |
| | #7 PROVIDE A COPY OF THE APPROVED SITE PLAN. |
| | |
| | #8 NEW FIRELINE WILL SERVE TWO BUILDINGS? BACKFLOW |
| | PROTECTION FOR EACH WILL BE REQUIRED. FIRE DEPT WILL |
| | HAVE TO OK THIS. |
| | |
| | #9 DOMESTIC WATER WILL SERVE SMALL BUILDING AND LARGE |
| | BUILDING? FOR LARGE BUILDING PROVIDE PUMP INFORMATION. |
| | IS THE BUILDING MULTI-STORY? REFLECT THAT ON SHEET C-3 |
| | PROVIDE PEAK GPM, ALSO ANY PUMP INFORMATION. |
| | |
| | #10 IS FRED GLADSTONE DRIVE A PRIVATE ROAD? |
| | |
| | #11 IS LORING DRIVE A PRIVATE ROAD? |
| | |
| | #12 ALL SEWER LINES MUST BE COLOR CODED "GREEN" AT |
| | EVERY 10' OR "GREEN" STRIPING OR FULL GREEN COLOR PIPE |
| | ACCEPTABLE. (STORM WATER AND CONDUITS REMAIN WHITE). |
| | PROVIDE NOTE ON PLANS. |
| | |
| | #13 GREASE SEPARATOR IS NOT SHOWN ON PLAN. YOU SHOW |
| | DETAIL ON C-5. |
| | |
| | #14 A LINE IS SHOWN RUNNING PARALLEL TO FRED GLADSTONE |
| | DRIVE; IT LOOKS LIKE IT'S GOING TO THE ROW OF HAVERHILL |
| | ROAD FROM A LIFT STATION ON-SITE. IDENTIFY? |
| | |
| | DRAIN EASEMENTS ? |
| | DUMPSTERS ? |
| | 80' UTIL EASEMENT ? |
| | |
| | |
| | |
| |
Print |