Plan Review Details - Project Z23040023
| Plan Review Stops For Project Z23040023 |
| Review Stop |
AIPP |
ART IN PUBLIC PLACES |
| Rev No |
1 |
Status |
F |
Date |
05-11-2023 |
|
|
Cont ID |
|
| Sent By |
swelter |
Date |
05-11-2023 |
Time |
09:50 |
Rev Time |
0.00 |
| Received By |
swelter |
Date |
05-11-2023 |
Time |
09:50 |
Sent To |
|
|
| Notes |
| 2023-05-11 09:50:37 | PROJECT SUBJECT TO PUBLIC ART REQUIREMENT. CONTACT | | | SYBILLE WELTER AT [email protected] TO SCHEDULE AN | | | INTRODUCTORY MEETING TO REVIEW THE REQUIREMENTS, | | | OPTIONS, AND PROCESS. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
05-10-2023 |
|
|
Cont ID |
|
| Sent By |
rbrown |
Date |
05-10-2023 |
Time |
20:05 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
05-10-2023 |
Time |
20:05 |
Sent To |
|
|
| Notes |
| 2023-05-10 20:14:51 | DEVELOPMENT SERVICES DEPARTMENT, BUILDING DIVISION, | | | COMMENTS: | | | | | | 1. THIS REVIEW IS A CURSORY REVIEW AS IT RELATES TO THE | | | SITE. IT IS NOT A REVIEW FOR FULL COMPLIANCE WITH | | | FLORIDA BUILDING CODE. THE FOLLOWING COMMENTS ARE TO BE | | | ADDRESSED FOR THE BUILDING PERMIT APPLICATION. | | | | | | 2. DEMOLITION OF THE EXISTING BUILDING. AN ASBESTOS | | | SURVEY SHALL BE PERFORMED AND AN ASBESTOS ABATEMENT | | | REPORT SUBMITTED TO THE HEALTH DEPARTMENT PALM BEACH | | | COUNTY OFFICE. CONTACT ALEX ORTEGA AT (561) 837-5963, | | | OR BY EMAIL: [email protected] | | | | | | 3. BUILDING SIZE. WHEN SUBMITTED FOR BUILDING PERMIT, | | | THE PLANS SHALL SHOW THAT THE TYPE OF CONSTRUCTION FOR | | | THE BUILDINGS WILL BE IN ACCORDANCE WITH THE HEIGHT, | | | AREA AND OCCUPANCY LIMITATIONS IN CHAPTER 5 OF THE | | | FLORIDA BUILDING CODE. | | | | | | 4. BUILDING LOCATION RELATIVE TO THE PROPERTY LINE AND | | | OTHER STRUCTURES. WHEN SUBMITTED FOR BUILDING PERMIT, | | | COMPLIANCE WITH ALL BUILDING SEPARATION, PERCENTAGE OF | | | OPENINGS AND OPENING PROTECTIVE REQUIREMENTS OF | | | CHAPTERS 6 AND 7 OF THE FLORIDA BUILDING CODE SHALL BE | | | VERIFIED. | | | | | | 5. EGRESS FROM ROOF DECK. ONLY ONE EXIT STAIR IS | | | PROPOSED FOR THE 3RD FLOOR DWELLING UNIT. THE PROPOSED | | | OCCUPANCY OF THE THE ROOF DECK IS OCCUPANCY OF A FOURTH | | | STORY ABOVE GRADE PLANE WHICH IS NOT PERMITTED FOR AN | | | OCCUPANCY WITH A SINGLE EXIT. SECTION 1006.3.3 OF | | | FLORIDA BUILDING CODE. | | | | | | 6. SEPARATE PERMITS REQUIRED. ALL APPLICABLE PERMITS | | | AND SUB-PERMITS MUST BE OBTAINED BEFORE COMMENCING THE | | | WORK. SEPARATE PERMITS, PLANS AND FEES, ARE REQUIRED | | | FOR SIGNS, SWIMMING POOLS AND SPAS, GAS SYSTEMS, | | | GENERATORS, FIRE ALARM SYSTEMS, FIRE SPRINKLER AND | | | OTHER FIRE SUPPRESSION SYSTEMS, BACKFLOW PREVENTERS, | | | GREASE INTERCEPTORS, SITE LIGHTING, SITE LANDSCAPE, | | | SITE IRRIGATION, ETC. | | | | | | 7. CONTRACTOR VEHICLE PARKING. PROPERTY OWNER AND | | | CONTRACTOR SHALL MAKE ARRANGEMENTS FOR PARKING OF | | | CONTRACTOR VEHICLES TO MINIMIZE THE IMPACT ON ALL | | | NEIGHBORING PROPERTIES. THE CONTRACTOR SHALL SUBMIT A | | | CONSTRUCTION PARKING PLAN TO THE ENGINEERING SERVICES | | | DEPARTMENT. | | | | | | 8. PROTECTION OF NEIGHBORING PROPERTY. PROPERTY OWNER | | | AND CONTRACTOR SHALL PROTECT ALL NEIGHBORING PROPERTY, | | | INCLUDING VEHICLES, FROM DAMAGE OR DIRT CAUSED BY THE | | | CONSTRUCTION, AND SHALL NOTIFY THE OCCUPANTS OF | | | NEIGHBORING PROPERTIES ABOUT ALL STAGES OF CONSTRUCTION | | | THAT MAY AFFECT THE USE OF THEIR PROPERTY. | | | | | | 9. ART IN PUBLIC PLACES. THIS PROJECT WILL BE SUBJECT | | | TO ART LIFE ASSESSMENT UNDER THE CITY OF WEST PALM | | | BEACH ART IN PUBLIC PLACES (AIPP) PROGRAM. FOR ADVICE | | | ON THE PROVISION OF PUBLIC ARTWORK IN LIEU OF THE AIPP | | | ASSESSMENT, CONTACT SYBILLE WELTER, ART IN PUBLIC | | | PLACES COORDINATOR, AT (561) 822-1521, OR BY EMAIL: | | | [email protected] | | | | | | ROBERT BROWN | | | BUILDING OFFICIAL | | | TEL: 561 805 6652 | | | EMAIL: [email protected] | | | |
|
|
| Review Stop |
ENG - PPRC |
ENGINEERING - PPRC |
| Rev No |
2 |
Status |
F |
Date |
07-28-2023 |
|
|
Cont ID |
|
| Sent By |
lquinone |
Date |
07-28-2023 |
Time |
11:09 |
Rev Time |
0.00 |
| Received By |
lquinone |
Date |
07-28-2023 |
Time |
11:09 |
Sent To |
|
|
| Notes |
| 2023-07-28 11:09:48 | | | | COMMENTS FROM LINDA M. QUINONES-CINTRON, PROJECT | | | COORDINATOR, ENGINEERING SERVICES AT 561-494-1085 | | | [email protected] | | | | | | WATER/WASTEWATER PLAN: | | | O PROVIDE CCTV VIDEO OF EXISTING SANITARY SEWER AND | | | STORMWATER INFRASTRUCTURE ALONG ENTIRE PROJECT FRONTAGE | | | (CONDITION OF SITE PLAN APPROVAL). | | | |
|
|
| Review Stop |
ENG - PPRC |
ENGINEERING - PPRC |
| Rev No |
1 |
Status |
F |
Date |
05-01-2023 |
|
|
Cont ID |
|
| Sent By |
lquinone |
Date |
05-01-2023 |
Time |
14:10 |
Rev Time |
0.00 |
| Received By |
lquinone |
Date |
05-01-2023 |
Time |
14:10 |
Sent To |
|
|
| Notes |
| 2023-05-01 14:10:57 | Z23040023 ??? SUBMITTAL COMMENTS ??? 1ST REVIEW | | | | | | COMMENTS FROM LINDA M. QUINONES-CINTRON, PROJECT | | | COORDINATOR, ENGINEERING SERVICES AT 561-494-1085 | | | [email protected] | | | GENERAL: | | | O PLEASE RESPOND TO ALL COMMENTS IN WRITING, AND | | | INCLUDE PROJECT NAME, ADDRESS AND PERMIT NUMBER | | | (Z-XXXXXXXX). | | | O THE CITY OF WEST PALM BEACH HAS A NUMBER OF | | | REGULATIONS AND PERMIT REQUIREMENTS WHICH DIRECTLY | | | AFFECT THE DEVELOPMENT AND INSTALLATION OF WATER AND | | | WASTEWATER UTILITIES WITHIN THE CITY. PLEASE SEE | | | DEVELOPMENT PERMIT SUBMITTAL REQUIREMENTS AT THE LINK | | | BELOW: | | | A. HTTP://WPB.ORG/CMSPAGES/GETAMAZONFILE.ASPX?PATH=~\WP | | | B_WEBSITE\MEDIA\ENGINEERING\DEVELOPMENT-APPLICATION-FUL | | | L-PACKAGE_2016.PDF&HASH=7BD4DD7EB6115181D8C5977BCC02A97 | | | B1960045731D3658206F27451722716EF | | | B. THIS AND OTHER RELATED ENGINEERING DOCUMENTS CAN BE | | | FOUND HERE: | | | HTTP://WPB.ORG/DEPARTMENTS/ENGINEERING-PUBLIC-WORKS/FOR | | | MS,-PERMITS-APPLICATIONS | | | C. ALSO SEE: CODE OF ORDINANCES, CITY OF WEST PALM | | | BEACH, FLORIDA, CODIFIED THROUGH ORD. NO. 4183-08, | | | ADOPTED SEPT. 22, 2008. (SUPPLEMENT NO. 18) | | | CHAPTER 90 UTILITIES, ARTICLE I. IN GENERAL, | | | SEC. 90-7. POLICY REGARDING EXTENSION OF WATER OR SEWER | | | SERVICE FACILITIES OF THE CITY. | | | THE WATER AND WASTEWATER SERVICE AGREEMENTS AND THE | | | CONSTRUCTION PERMITS ADDRESS RESERVATION OF CAPACITY | | | BASED ON USAGE, METER SIZE AND FEES, DESIGN STANDARDS, | | | BACKFLOW PREVENTION, FIRE SERVICE AND IRRIGATION. | | | O AS OF DECEMBER 20, 2015, THE CITY OF WEST PALM BEACH | | | CROSS-CONNECTION CONTROL MANUAL HAS BEEN REVISED, | | | STATING "ALL BACKFLOW DEVICES MUST BE LEAD-FREE". FOR | | | MORE INFORMATION, REFER TO THE LINK BELOW: | | | A. HTTP://WPB.ORG/DEPARTMENTS/PUBLIC-UTILITIES/FORMS-PU | | | BLICATIONS/BACKFLOW-CROSS-CONNECTION- CONTROL-MANUAL | | | O PLEASE SUBMIT A FORMAL AS-BUILT REQUEST FOR ALL CITY | | | OF WEST PALM BEACH-OWNED UTILITIES WITHIN THE PUBLIC | | | RIGHT OF WAY FOR THE ENTIRE EXTENT OF THE LIMITS OF | | | YOUR PROJECT. IDENTIFY TYPE OF UTILITY, LOCATION, PIPE | | | MATERIAL, AGE AND SIZE. PLEASE CONTACT JANICE TARBILL | | | IN THE WPB ENGINEERING SERVICES DEPARTMENT AT | | | [email protected] OR 561-494-1079 FOR FURTHER | | | ASSISTANCE. NOTE THAT FIELD RECORDS ARE FOR INFORMATION | | | ONLY. FIELD VERIFY UTILITY LOCATIONS USING FIELD | | | SURVEY, POT-HOLING, SOFT DIGS ETC. | | | O PROVIDE EXISTING AND PROPOSED PERVIOUS AND IMPERVIOUS | | | DATA. | | | | | | BACKFLOW ASSEMBLY AND METERS: | | | O PROVIDE ENLARGED VIEW ON PLANS OF PROPOSED LOCATION | | | OF WATER METER AND BACKFLOW | | | PREVENTION. | | | | | | WATER/WASTEWATER PLAN: | | | O PLANS SHALL SHOW EXISTING AND PROPOSED LOCATIONS AND | | | DIMENSIONS OF ALL WATER, STORMWATER, AND SANITARY AND | | | SEWER LINES AND CLEANOUTS, INCLUDING STUBS TO EACH | | | PROPERTY LINE FOR WATER AND SANITARY SEWERS, THE MAKE | | | AND MODEL OF ALL VALVES, POTABLE AND IRRIGATION METERS, | | | BACKFLOWS, FIRE HYDRANTS AND FDCS, AND OTHER DEVICES TO | | | BE INSTALLED ON THE SYSTEM, CATCH BASINS, CULVERTS, | | | DITCHES INCLUDING GRADES, PIPES SIZES, MATERIALS, | | | ELEVATIONS, ASSUMPTIONS, CALCULATIONS, INVERT | | | ELEVATIONS FOR ALL INLETS AND MANHOLES AND PROFILES OF | | | SANITARY SEWER LINES. | | | O GATE VALVE BOXES SHALL NOT BE INSTALLED IN CURB OR | | | SIDEWALK. ALL AVAILABLE ELEVATION SHALL BE SHOWN ON THE | | | PROFILE VIEW. | | | O DIRECTION OF FLOW SHALL BE SHOWN ON PLAN VIEW FOR ALL | | | SANITARY AND STORM SEWERS. | | | O PLAN VIEW SHALL SHOW ALL EXISTING AND PROPOSED | | | UNDERGROUND UTILITY LAYOUT, INCLUDING FIBER OPTIC, | | | ELECTRIC, GAS, AND CABLEVISION & TELECOMMUNICATION | | | FACILITIES INCLUDING PIPE SIZE AND MATERIAL LOCATED IN | | | THE RIGHT-OF-WAY. | | | O PROVIDE PROFILE AND CLEARANCES BETWEEN WATER, SEWER | | | AND STORM LINES PER CITY OF WEST PALM BEACH STANDARD | | | DETAIL GN-2 SERIES, AT ALL UTILITY CROSSINGS. PLEASE | | | INCLUDE FIBER OPTIC, ELECTRIC, GAS, AND CABLEVISION & | | | TELECOMMUNICATION FACILITIES INCLUDING PIPE SIZE AND | | | MATERIAL LOCATED IN THE RIGHT-OF-WAY. | | | O SUBMIT COMPLETED LOS ANALYSIS SUMMARY TABLE DIRECTLY | | | TO ENGINEERING (SHEET 33 OF CITY OF WPB DEVELOPMENT | | | APPLICATION). PROVIDE CALCULATIONS ON PLANS OF EXISTING | | | AND PROPOSED DEMANDS FOR WATER & SEWER (AVERAGE, | | | MAXIMUM AND PEAK) AND FIRE FLOW DEMANDS. CALCULATIONS | | | SHALL BE PER FAC 64E-6 FOR SEWER AND PER FAC 64-E.008 | | | FOR WATER. | | | O PROVIDE CCTV VIDEO OF EXISTING SANITARY SEWER AND | | | STORMWATER INFRASTRUCTURE ALONG ENTIRE PROJECT FRONTAGE | | | (CONDITION OF SITE PLAN APPROVAL). | | | O CUT AND CAP UTILITIES NOT IN USE AND REMOVE ANY | | | ABANDONED UTILITY LINES LARGER THAN 2 INCHES FROM CITY | | | ROW. | | | O WHEN PROPOSED, WATER MAINS IN CITY RIGHT OF WAY SHALL | | | BE MADE OF DUCTILE IRON PIPE (NOT PVC) AND SPECIFY | | | PROPOSED LENGTH IN FEET. | | | O CHECK TO SEE IF FDEP FORMS FOR PROPOSED SANITARY | | | SEWER ARE REQUIRED. | | | O PROVIDE CLEANOUTS FOR PROPOSED SANITARY LINE ONSITE | | | JUST INSIDE PROPERTY LINE, AT JOINTS AND EVERY 75 FEET. | | | O ADD NOTE TO PLANS SPECIFYING CITY???S DOWNSTREAM LIFT | | | STATION NUMBER. | | | O PROVIDE ONSITE CLEANOUTS NEAR PROPERTY LINE FOR | | | PROPOSED SANITARY LATERALS. | | | O LABEL WATER LINES AS PRIVATE WHERE APPLICABLE. | | | O PLEASE SHOW AND LABEL EXISTING AND PROPOSED GREASE | | | TRAPS (IF ANY). | | | O PER CITY STANDARDS MAINTAIN MINIMUM DISTANCE BETWEEN | | | OUTSIDE DIAMETER OF CITY PIPE AND ROOT BARRIER. | | | | | | FORMAL ENGINEERING REVIEW: | | | O FOR FORMAL ENGINEERING SUBMITTAL, SFWMD ERP AND NPDES | | | NOI REQUIREMENTS WILL BE ENFORCED. | | | - AN NOI IS REQUIRED FOR PROJECTS THAT: | | | - 1) DISTURB ONE OF MORE ACRES OF LAND OR DISTURB LESS | | | THAN ON ACRE OF LAND BUT ARE PART OF A COMMON PLAN OF | | | DEVELOPMENT OR SALE; | | | - 2) DISCHARGE STORMWATER TO SURFACE WATERS OF THE | | | STATE OR TO SURFACE WATERS OF THE STATE THROUGH A | | | MUNICIPAL SEPARATE STORM SEWER SYSTEM (MS4). | | | - THE SFWMD ERP CAN BE OBTAINED THROUGH A 10-2 SELF | | | CERTIFICATION THROUGH FDEP OR AN ERP APPLICATION | | | THROUGH SFWMD. EITHER WAY, THE DEVELOPER/ENGINEER SHALL | | | SUBMIT A COPY OF THE ERP PERMIT OR FDEP ACKNOWLEDGEMENT | | | OF THE 10-2 CERTIFICATION. | | | O FOR FORMAL ENGINEERING SUBMITTAL, PLEASE PROVIDE | | | EASEMENT FOR PLACEMENT OF PROPOSED WATER METERS. | | | O FOR FORMAL ENGINEERING SUBMITTAL, PROVIDE PROFILES OF | | | WATER AND SEWER AND SHOW ANY CROSSINGS/CONFLICTS. | | | O FOR FORMAL ENGINEERING SUBMITTAL, WHEN SUBMITTING | | | APPROVED MATERIALS LIST, PLEASE PROVIDE MATERIAL/CUT | | | SHEETS FOR ALL PROPOSED BACKFLOW DEVICES SHOWING | | | SPECIFIC MODEL NUMBER AND SPECIFYING USC APPROVED | | | LEAD-FREE DESIGN. | | | O FOR FORMAL ENGINEERING SUBMITTAL, IF SANITARY LINES | | | ARE PROPOSED IN ROW PLEASE SHOW ADJACENT SANITARY | | | LATERAL LOCATIONS AND SHOW ADDRESSES OF ADJACENT | | | PARCELS. | | | O FOR FORMAL ENGINEERING SUBMITTAL, IF WATER LINES ARE | | | BEING REPLACED IN ROW, SHOW ADJACENT PARCEL ADDRESSES. | | | O FOR FORMAL ENGINEERING SUBMITTAL, ADD NOTE TO PROVIDE | | | 50 FT. PAVEMENT RESTORATION TRANSITION ON EACH SIDE OF | | | PROPOSED TRENCH IN CITY MAINTAINED ROADWAY AREAS PER | | | CITY OF WPB STANDARD DETAIL GC-8. | | | O FOR FORMAL ENGINEERING SUBMITTAL, PLEASE PROVIDE | | | CALCULATIONS OF PERVIOUS AND IMPERVIOUS AREAS FOR | | | PROPOSED IMPROVED AREAS. | | | | | | QUESTIONS AND COORDINATION CONTACTS: | | | O MARK HURLEY, FIELD CUSTOMER SERVICE SUPERVISOR WITH | | | CITY OF WPB PUBLIC UTILITIES, REGARDING PLACEMENT OF | | | BACKFLOW DEVICES AND WATER METERS. CONTACT HIM AT | | | 561-822-2262 OR [email protected] | | | O COMMENTS FROM MIKE TECHNOW, PUB. UTILITIES ENGINEER, | | | [email protected], 561-494-1047: | | | O COMMENTS FROM RICKY ELIZONDO, PUB. UTILITIES PLANS | | | EXAMINER, [email protected] , 561-494-1101: | | | O COMMENTS FROM TRACY WARD, SR. STORMWATER ENGINEER, | | | ENG. SERVICES DEPT. AT 561-494-1120 OR [email protected] | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
07-25-2023 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
07-25-2023 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
07-25-2023 |
Time |
12:41 |
Sent To |
|
|
| Notes |
| 2023-07-25 12:42:19 | FIRE HAS NO OBJECTIONS TO THE PROPOSED AND APPROVES. | | | | | | FIRE'S APPROVAL OF THIS SUBMITTED PROJECT MAY NOT | | | CONSTITUTE IT'S FINAL REVIEW OR APPROVAL. | | | | | | IF APPLICABLE, FIRE SHALL REVIEW ALL SUBMITTED PROJECT | | | PLANS AT THE APPLICABLE TIME AND IN ACCORDANCE WITH THE | | | REQUIREMENTS OF ALL APPLICABLE FIRE CODES AND | | | STANDARDS. | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
05-05-2023 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
05-05-2023 |
Time |
11:58 |
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
05-05-2023 |
Time |
11:31 |
Sent To |
|
|
| Notes |
| 2023-05-05 11:37:35 | THE FOLLOWING COMMENTS WERE SUBMITTED BY PETER LEDUC, | | | FIRE MARSHAL, BUREAU OF FIRE PREVENTION, WEST PALM | | | BEACH FIRE DEPARTMENT. | | | | | | THIS REVIEW CAN ONLY BE CONSIDERED PRELIMINARY AS THE | | | DRAWINGS THAT WERE REVIEWED WERE NOT COMPLETE. | | | ADDITIONAL COMMENTS CAN BE EXPECTED WHEN FULL DRAWINGS | | | ARE SUBMITTED FOR PERMIT. | | | | | | THE FIRE PREVENTION BUREAU HAS NO OBJECTIONS TO THE | | | PROPOSED PROJECT. THE FOLLOWING COMMENTS ARE INTENDED | | | TO PROVIDE GUIDANCE FOR BUILDING PLAN SUBMITTAL. | | | | | | 1. CONSTRUCTION, DEMOLITION, AND RENOVATION TO COMPLY | | | WITH NFPA 241. EXTRA ATTENTION SHALL BE GIVEN TO THE | | | PERMITTING AND LOCATION OF CONSTRUCTION TRAILERS. A | | | PERMIT IS REQUIRED FOR ANY CONSTRUCTION TRAILER RELATED | | | TO THIS PROJECT. SEPARATION DISTANCES FROM MAIN | | | STRUCTURES AS WELL AS OTHER TRAILERS SHALL BE CLOSELY | | | MONITORED FOR THE REQUIREMENTS OF FIRE SPRINKLER | | | PROTECTION. | | | | | | 2. SITE ACCESS AND EXIT POINTS ARE TO BE CLEARLY | | | IDENTIFIED AND MAINTAINED FOR EMERGENCY VEHICLES DURING | | | ALL CONSTRUCTION ACTIVITIES. | | | | | | 3. THE BUILDING ADDRESS SHALL BE CLEARLY VISIBLE FROM | | | ALL ACCESS ROADWAYS, INCLUDING DURING CONSTRUCTION. | | | ADDRESS NUMBERS SHALL CONTRAST WITH THEIR BACKGROUND | | | AND SHALL NOT BE LESS THAN SIX (6) INCHES IN HEIGHT | | | WITH A ONE (1) INCH STROKE FOR ALL BUILDINGS. | | | | | | 4. DURING CONSTRUCTION, TRASH AND DEBRIS IS TO BE | | | REMOVED FROM THE SITE DAILY OR MORE OFTEN TO REDUCE THE | | | ACCUMULATION OF POTENTIAL LIFE AND FIRE SAFETY HAZARDS. | | | | | | 5. THE CONSTRUCTION OF THE BUILDING(S) SHALL COMPLY | | | WITH THE 7TH EDITION OF THE FLORIDA FIRE PREVENTION | | | CODE, INCLUDING NFPA 1 & 101, AND ALL ASSOCIATED FIRE | | | CODES. | | | | | | 6. FOR PLAN REVIEW SUBMITTAL, PLEASE INCLUDE THE | | | OCCUPANCY TYPE PER THE FLORIDA FIRE PREVENTION CODE. | | | | | | 7. FOR PLAN REVIEW SUBMITTAL, PLEASE ENSURE THAT A FIRE | | | LOAD CALCULATION IS INCLUDED, AND THAT ADEQUATE WATER | | | SUPPLY IS EXISTING OR WILL BE PROVIDED. | | | | | | 8. ALL EXISTING AND NEW FIRE HYDRANTS PLANNED FOR THIS | | | DEVELOPMENT SHALL BE CLEARLY INDICATED AND IDENTIFIED | | | ON THE PLAN AND CLOSELY COORDINATED WITH THE BUREAU OF | | | FIRE PREVENTION. | | | | | | THE PROPOSED LOCATION OF THE FIRE HYDRANT AND FDC SHALL | | | BE WITHIN 100' OF EACH OTHER AND CLOSELY COORDINATED | | | WITH THE BUREAU OF FIRE PREVENTION. | | | | | | THE PROPOSED LOCATIONS ON THE CIVIL PLAN ARE | | | ACCEPTABLE. | | | | | | 9. PROVIDE FOR A FIRE SPRINKLER AND/OR FIRE ALARM PER | | | THE APPLICABLE OCCUPANCY CODE. FOR ANY LIFE SAFETY | | | ENGINEERED SYSTEM, I.E FIRE SPRINKLER AND FIRE ALARM, | | | ENSURE THEY COMPLY WITH THE REQUIREMENTS OF F.A.C. 61G | | | AND SUBMITTED WITH THE MASTER PERMIT. | | | | | | 9A. THE LOCATION OF ANY APPLICABLE DDCV AND FIRE LINE | | | LOCATIONS SHALL MEET AND BE INSTALLED PER THE | | | REQUIREMENTS OF NFPA 24 AND SHALL BE COORDINATED WITH | | | THE OFFICE OF FIRE MARSHAL, THE CITY'S ENGINEERS | | | OFFICE, THE LANDSCAPE PLANNER, AND THE CITY'S PLANNING | | | AND ZONING OFFICE. | | | | | | 10. COMPLETE LIFE SAFETY PLANS FOR THE OCCUPANCY SHALL | | | BE PROVIDED THAT ILLUSTRATE OCCUPANT LOADS, TRAVEL | | | DISTANCES, EXIT SEPARATION DISTANCES, COMMON PATHS OF | | | TRAVEL, DEAD-END CORRIDORS, EXIT SIGNS, EMERGENCY | | | LIGHTING, EXITS LEADING TO A PUBLIC WAY, FIRE | | | EXTINGUISHER LOCATIONS, AND ALL FIRE SAFETY FEATURES | | | AND EQUIPMENT. | | | | | | 11. IT IS HIGHLY RECOMMENDED (REQUIRED WITH FIRE | | | SPRINKLER SYSTEM) THAT A KNOX BOX WITH KEYS FOR ENTRY | | | DOOR LOCKS BE PROVIDED FOR 24 HOUR EMERGENCY ACCESS. | | | | | | 12. AREAS OF REFUGE SHALL BE PROVIDED AS REQUIRED PER | | | THE FLORIDA BUILDING CODE AND NFPA 101, CH 7, MEANS OF | | | EGRESS. | | | | | | 12A. ALL ELEVATORS SHALL BE EQUIPPED WITH A REGION 7 | | | KEYWAY SYSTEM IN BUILDINGS 6 OR MORE STORIES PER THE | | | F.A.C. | | | | | | ALL NEW ELEVATORS SHALL CONFORM TO THE FIRE FIGHTER???S | | | EMERGENCY OPERATIONS REQUIREMENTS OF ASME A17.1/CSA | | | B44, SAFETY CODE FOR ELEVATORS. | | | | | | ANY BUILDING THAT IS MORE THAN THREE STORIES HIGH OR IN | | | WHICH THE VERTICAL DISTANCE BETWEEN THE BOTTOM TERMINAL | | | LANDING AND THE TOP TERMINAL LANDING EXCEEDS 25 FEET | | | MUST BE CONSTRUCTED TO CONTAIN AT LEAST ONE PASSENGER | | | ELEVATOR THAT IS OPERATIONAL AND WILL ACCOMMODATE AN | | | AMBULANCE STRETCHER 76 INCHES LONG AND 24 INCHES WIDE | | | IN THE HORIZONTAL POSITION. | | | | | | 13. TWO-WAY RADIO COMMUNICATIONS ENHANCEMENT SYSTEMS. | | | | | | NFPA 1, CHAPTER 11, BUILDING SERVICES; 11.10 TWO-WAY | | | RADIO ENHANCEMENT SERVICES. | | | 11.10.1 IN ALL NEW AND EXISTING BUILDINGS, MINIMUM | | | RADIO SIGNAL STRENGTH FOR FIRE DEPARTMENT | | | COMMUNICATIONS SHALL BE MAINTAINED AT A LEVEL | | | DETERMINED BY THE AHJ. | | | | | | CONTACT WILL NEED TO BE MADE TO MARK FILLA, PALM BEACH | | | COUNTY PUBLIC SAFETY RADIO SYSTEMS MANAGER, | | | [email protected], 561-233-0837; AS OUR RADIOS OPERATE | | | ON THEIR SYSTEM FOR DETAILED RADIO FREQUENCY AND | | | INSTALLATION INSTRUCTIONS. | | | | | | 14. THE BUREAU'S APPROVAL OF THIS SUBMITTED PROJECT | | | DOES NOT CONSTITUTE ITS FINAL REVIEW OR APPROVAL. | | | | | | 15. THE BUREAU SHALL REVIEW ALL SUBMITTED BUILDING | | | PLANS AT THE APPROPRIATE TIME AND IN ACCORDANCE WITH | | | THE REQUIREMENTS OF ALL APPLICABLE CODES AND STANDARDS. | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | |
|
|
| Review Stop |
PU |
PUBLIC UTILITIES |
| Rev No |
1 |
Status |
F |
Date |
05-11-2023 |
|
|
Cont ID |
|
| Sent By |
relizond |
Date |
05-11-2023 |
Time |
11:15 |
Rev Time |
0.00 |
| Received By |
relizond |
Date |
05-11-2023 |
Time |
11:11 |
Sent To |
|
|
| Notes |
| 2023-05-11 11:14:56 | -LIST SIZE AND MATERIAL FOR ALL EXISTING AND PROPOSED | | | UTILITIES | | | -LABEL ALL EXISTING UTILITIES WITH IN THE PROJECT SCOPE | | | DENOTE CITY'S POINT OF SERVICE | | | -PROVIDE A PROFILE FOR THE FIRE LINE FROM THE TAP TO | | | THE CITY'S POINT OF SERVICE TO ENSURE PROPER CLEARANCES | | | FOR UTILITY CONFLICTS | | | -INCLUDE TOP/BOP ELEVATIONS FOR ALL UTILITY CONFLICTS | | | -PROVIDE PROJECT ADDRESS AS WELL AS ADJACENT PARCELS | | | -SHOW ALL UNDERGROUND DRY UTILITIES WITHIN THE PROJECT | | | LIMITS | | | -TRENCH RESTORATION NEEDED PER CITY DETAIL GC-8 | | | -DENOTE THE LIFT STATION BOUNDARY THAT THE PROJECT | | | FALLS WITHIN | | | - ENSURE GATE VALVE INSTALLATION WILL BE OUTSIDE OF | | | SIDEWALK OR CURB AREAS | | | -VERIFY THAT PROPOSED SANITARY SEWER CONNECTION IS | | | DEDICATED TO PROJECT LOCATION AND NOT PROPERTY TO THE | | | SOUTH. | | | -CCTV OF MAINS ON OLIVE AND ALLEY TO THE NORTH REQUIRED | | | IN ORDER TO DETERMINE LOCATION OF EXISTING LATERALS | | | (MANHOLE TO MANHOLE) | | | -WATER MAIN CONNECTIONS IN THE ALLEY ARE TO ASBESTOS | | | CONCRETE PIPE. WHICH WOULD REQUIRE REPLACEMENT | | | -WATER METER CANNOT BE LOCATED ON PRIVATE PROPERTY | | | -FIRE HYDRANT CONNECTION MADE VIA ANCHOR TEE PER P-8 |
|
|
| Review Stop |
PU-CS |
PUBLIC UTILITIES CUSTOMER SRVC |
| Rev No |
2 |
Status |
F |
Date |
07-25-2023 |
|
|
Cont ID |
|
| Sent By |
mhurley |
Date |
07-25-2023 |
Time |
13:11 |
Rev Time |
0.00 |
| Received By |
mhurley |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2023-07-25 13:11:18 | PLEASE PROVIDE WRITTEN RESPONSES TO THE FOLLOWING: | | | -ENSURE MINIMUM 3 FEET HORIZONTAL CLEARANCE DISTANCE | | | BETWEEN WATER METER BOX AND TREE TRUNK. | | | -WHAT ARE THE TWO GREEN CIRCLES NEAR THE WESTERN | | | PROPERTY LINE SHOWN ON SHEET C2.2? PLEASE LABEL OR ADD | | | TO LEGEND. | | | RESPECTFULLY, | | | MARK HURLEY [email protected] |
|
|
| Review Stop |
PU-CS |
PUBLIC UTILITIES CUSTOMER SRVC |
| Rev No |
1 |
Status |
F |
Date |
05-05-2023 |
|
|
Cont ID |
|
| Sent By |
mhurley |
Date |
05-05-2023 |
Time |
15:11 |
Rev Time |
0.00 |
| Received By |
mhurley |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2023-05-05 15:11:00 | PLEASE PROVIDE WRITTEN RESPONSES TO THE FOLLOWING: | | | -UTILITY BILLING SYSTEM SHOWS EXISTING WATER METER SIZE | | | TO BE 5/8 INCH. PLEASE CONFIRM IF THAT WILL BE | | | SUFFICIENT FOR IRRIGATION. | | | -EXISTING METERED WATER SERVICE CURRENTLY DOES NOT HAVE | | | AN ACTIVE USAGE BILLING ACCOUNT AND THE WATER CANNOT BE | | | USED. ACCOUNT WOULD HAVE TO BE STARTED AND ANY FEES, | | | CHARGES, AND DEPOSITS PAID BEFORE COULD BE USED. | | | -VERIFY PRIVATE FIRELINE WILL NOT HAVE ANY ADDED | | | CHEMICALS OR AUXILIARY WATER SOURCES SUCH AS WELLS. | | | -VERIFY SLIDING GATE WILL NOT HIT FIRELINE BACKFLOW | | | ASSEMBLY. | | | -FIRELINE BACKFLOW ASSEMBLY WILL HAVE A CITY DETECTOR | | | WATER METER ON IT. PROPERTY OWNER AND UTILITY ACCOUNT | | | HOLDER MUST ALLOW ACCESS AS NEEDED TO UTILITY PERSONNEL | | | FOR THE PURPOSES OF READING AND MAINTAINING THE METER. | | | -ON ENGINEERING PLANS, SHOW EXISTING UTILITY EASEMENT | | | AT EAST SIDE OF PROPERTY IF IT WILL REMAIN. ALSO SHOW | | | UTILITY EASEMENT FOR WATER METER IF WILL BE ON PRIVATE | | | PROPERTY. | | | -IS A WALL ABOVE/OVER PROPOSED 2 INCH WATER SERVICE | | | LINE? | | | -BACKFLOW ASSEMBLY WAS INSTALLED FOR EXISTING METER, | | | BUT NEVER INSPECTED. BEFORE EXISTING WATER SERVICE | | | COULD BE TURNED ON AND USED, INSTALLATION WOULD NEED TO | | | PASS INSPECTION AND THEN INTERNAL TEST WOULD BE NEEDED. | | | CHARGES WOULD GO TO THE NEW UTILITY ACCOUNT. | | | RESPECTFULLY, | | | MARK HURLEY [email protected] | | | |
|
|
| Review Stop |
PW |
PUBLIC WORKS |
| Rev No |
2 |
Status |
P |
Date |
07-26-2023 |
|
|
Cont ID |
|
| Sent By |
jbjoseph |
Date |
07-26-2023 |
Time |
13:15 |
Rev Time |
0.00 |
| Received By |
jbjoseph |
Date |
07-26-2023 |
Time |
13:15 |
Sent To |
|
|
| Notes |
| 2023-07-26 13:15:45 | NO COMMENTS. APPROVED |
|
|
| Review Stop |
PW |
PUBLIC WORKS |
| Rev No |
1 |
Status |
F |
Date |
05-10-2023 |
|
|
Cont ID |
|
| Sent By |
jbjoseph |
Date |
05-10-2023 |
Time |
14:27 |
Rev Time |
0.00 |
| Received By |
jbjoseph |
Date |
05-10-2023 |
Time |
14:25 |
Sent To |
|
|
| Notes |
| 2023-05-10 14:26:48 | PLEASE PROVIDE THE FOLLOWING: | | | 1. PLEASE SHOW LOCATION OF DUMPSTER ENCLOSURE. | | | 2. DUMPSTER ENCLOSURE DETAILS FOR SANITATION SERVICE | | | (I.E. SOLID WASTE CONTAINER(S) TYPE, COLLECTION | | | LOCATION, ETC.). FOR A FREESTANDING SITE DUMPSTER | | | ENCLOSURE. THE ENCLOSURE SHALL COMPLY WITH THE LATEST | | | REVISION OF CITY OF WEST PALM BEACH GENERAL | | | CONSTRUCTION GARBAGE ENCLOSURE STANDARD, GC-7 | | | 3. LOS (LEVEL OF SERVICE ANALYSIS) TO REFLECT THE SOLID | | | WASTE VOLUME PRODUCED ALONG WITH THE SIZE, TYPE AND | | | QUANTITY OF THE CONTAINER (I.E. DUMPSTER/COMPACTOR) | | | THAT WILL BE FOR THE SANITATION SERVICE. | | | | | | BRUCELY A. JOSEPH | | | PW PROGRAM MANAGER | | | 561-494-1141 | | | |
|
|
| Review Stop |
STORM |
STORMWATER |
| Rev No |
2 |
Status |
P |
Date |
07-24-2023 |
|
|
Cont ID |
|
| Sent By |
tward |
Date |
07-24-2023 |
Time |
09:21 |
Rev Time |
0.00 |
| Received By |
tward |
Date |
07-24-2023 |
Time |
09:24 |
Sent To |
|
|
| Notes |
| 2023-07-24 09:23:53 | .CONVERSION EQUATION BETWEEN NAVD1988 AND NGVD1929 ON | | | SURVEY (1.52 FEET) DIFFERS FROM THE CIVIL PLANS (1.50 | | | FEET). RECTIFY THIS DISCREPANCY ON THE ENGINEERING | | | PERMIT SUBMITTAL. | | | | | | TRACY WARD, PE | | | SENIOR STORMWATER ENGINEER | | | ENGINEERING SERVICES DEPARTMENT | | | 561-494-1120 (O) | | | [email protected] | | | |
|
|
| Review Stop |
STORM |
STORMWATER |
| Rev No |
1 |
Status |
F |
Date |
05-10-2023 |
|
|
Cont ID |
|
| Sent By |
tward |
Date |
05-10-2023 |
Time |
13:41 |
Rev Time |
0.00 |
| Received By |
tward |
Date |
05-10-2023 |
Time |
13:42 |
Sent To |
|
|
| Notes |
| 2023-05-10 13:41:54 | THIS IS A CONCEPTUAL LEVEL REVIEW. CONSTRUCTION LEVEL | | | DETAILS, DESIGN CALCULATIONS AND THE POLLUTION | | | PREVENTION PLAN WILL BE REVIEWED AS PART OF THE | | | ENGINEERING DEVELOPMENT APPROVAL AND BUILDING PERMIT | | | APPLICATION PROCESSES. | | | | | | THE FOLLOWING COMMENTS MUST BE ADDRESSED PRIOR TO SITE | | | PLAN APPROVAL: | | | | | | 1. THE CITY'S OFFICIAL VERTICAL DATUM PER CITY CODE IS | | | NGVD1929. THE NAVD1988 VERTICAL DATUM MAY BE USED IF | | | THE CONVERSION EQUATION BETWEEN NAVD1988 AND NGVD1929 | | | IS PROVIDED. LABEL THE VERTICAL DATUM ON THE SURVEY AND | | | LIST THE CONVERSION TO NGVD1929. | | | | | | 2. REVIEW ALLOWABLE SLOPING REQUIREMENTS FOR HANDICAP | | | PARKING SPACES (MAX. 2% IN ALL DIRECTIONS) AND ADJUST | | | PROPOSED GRADES ACCORDINGLY. | | | | | | 3. CREATE RETENTION AREAS BEHIND THE SIDEWALKS TO HOLD | | | STORMWATER RUNOFF ONSITE. | | | | | | 4. LABEL PERIMETER WALLS / FENCES. | | | | | | 5. INDICATE HOW/WHERE THE AREA SOUTH OF THE BUILDING | | | WILL DRAIN. | | | | | | 6. CONNECT ROOF DRAINS DIRECTLY TO THE STORMWATER | | | DRAINAGE SYSTEM. | | | | | | 7. NO STORMWATER RUNOFF IS ALLOWED TO FLOW ONTO | | | ADJACENT PRIVATE PROPERTY. | | | | | | 8. PROVIDE A CROSS SECTION AT THE DRIVEWAY FROM THE | | | NORTH ALLEY R/W TO THE SOUTH PROPERTY LINE OF THE SITE. | | | SHOW SURFACE FEATURES, GENERAL DIRECTION OF HOW | | | SURFACES SLOPE, LOCATION OF HIGH POINT SOUTH OF THE | | | ALLEY, DIMENSIONS, ETC. CREATE A HIGH POINT IN THE | | | DRIVEWAY SOUTH OF THE NORTH PROPERTY LINE TO KEEP THE | | | ALLEY RUNOFF FROM FLOWING INTO THE ONSITE DRAINAGE | | | SYSTEM. THE NORTH CATCH BASIN WILL NEED TO BE LOCATED | | | SOUTH OF THE HIGH POINT..THE DRIVEWAY PAVER AREA SHOULD | | | BE SLOPED TO THE CATCH BASINS. | | | | | | | | | THE FOLLOWING COMMENTS MUST BE ADDRESSED PRIOR TO | | | ISSUANCE OF CONSTRUCTION AUTHORIZATION INCLUDING | | | BUILDING PERMITS AND ENGINEERING DEVELOPMENT APPROVAL. | | | | | | 1. DRAINAGE SYSTEM TO BE DESIGNED TO MEET SFWMD ERP | | | CRITERIA. STORMWATER CALCULATIONS WILL BE REVIEWED WITH | | | THE ENGINEERING PERMIT SUBMITTAL. | | | | | | 2. PROVIDE COPY OF SFWMD ERP AND FDEP NPDES | | | CONSTRUCTION PERMIT BEFORE START OF CONSTRUCTION. | | | | | | 3. PROVIDE EROSION AND SEDIMENT CONTROL PLAN WITH THE | | | ENGINEERING PERMIT SUBMITTAL. | | | | | | TRACY WARD, PE | | | SENIOR STORMWATER ENGINEER | | | ENGINEERING SERVICES DEPARTMENT | | | 561-494-1120 (O) | | | [email protected] | | | |
|
|
| Review Stop |
SURVEY |
SURVEYING |
| Rev No |
1 |
Status |
F |
Date |
05-10-2023 |
|
|
Cont ID |
|
| Sent By |
vnoel |
Date |
05-10-2023 |
Time |
10:02 |
Rev Time |
0.00 |
| Received By |
vnoel |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2023-05-10 10:16:03 | 1. IS EXISTING FPL POLES IN THE REAR UTILITY EASEMENT | | | TO BE UNDERGROUNDED? | | | 2. LANDSCAPE PLANS SHOWS 2 TREES IN EASEMENT TO REMAIN | | | BUT NOT SHOWN ON SURVEY. | | | 3. SHOW UE ON ENG. PLANS. | | | 4. WATER MAIN IN ALLEY IS FROM THE 1930'S. ANY NEW TAPS | | | MAY BE REQUIRED TO BE IN OLIVE AVE. | | | 5. ADD DATUM FOR ELEVATIONS ON SURVEY. ADD CONVERSION | | | TO NGVD-29 IF ELEVATIONS ARE NAVD-88. |
|
|
| Review Stop |
TRAFFIC |
TRAFFIC ENGINEERING |
| Rev No |
1 |
Status |
F |
Date |
05-11-2023 |
|
|
Cont ID |
|
| Sent By |
|
Date |
05-11-2023 |
Time |
|
Rev Time |
0.00 |
| Received By |
|
Date |
05-11-2023 |
Time |
|
Sent To |
|
|
| Notes |
| 2023-05-11 00:28:38 | TRAFFIC COMMENTS | | | 1) PROVIDE COUNTY TPS LETTER, ONCE RECEIVED | | | | | | SITE COMMENTS | | | 2) PROVIDE A TRANSPORTATION SPECIFIC SITE PLAN FOR THE | | | GROUND FLOOR. SHOWCASING TRANSPORTATION RELATED | | | FEATURES (E.G. ROADWAY & EACH TRAVEL LANE WIDTHS, | | | DRIVING AISLES, PARKING STALLS, SIDEWALK, CURB, GUTTER, | | | DRIVEWAY, GATES, CROSSWALKS, VISIBILITY TRIANGLE, | | | CORNER & DRIVEWAY SEPARATION DISTANCES, SLOPES, ETC.) | | | PROPERLY LABELED AND DIMENSIONED. PLEASE PROVIDE | | | DOCUMENT NAME OR SHEET NUMBER | | | 3) IN THE TRANSPORTATION SITE PLAN, PLEASE SHOWCASE | | | BASIC CURB DETAILS (E.G. DRIVEWAY, CURB CUTS, PAVEMENT | | | MARKINGS, PARKING STALLS, ETC.) ON THE OPPOSITE SIDE OF | | | THE ROADS, INCLUSIVE OF THE ALLEY, SURROUNDING THE | | | PROPOSED DEVELOPMENT | | | 4) PROVIDE A SIGNAGE AND PAVEMENT MARKING PLAN. | | | INCLUSIVE OF ALL FEATURES WITHIN THE PROPOSED | | | DEVELOPMENT AND ALONG ALL ROADS FRONTING THE SITE. SUCH | | | PLAN COULD BE INTEGRATED IN THE TRANSPORTATION SITE | | | PLAN | | | 5) PROVIDE AUTOTURN ANALYSIS FOR GARBAGE TRUCK AND/OR | | | SERVICE VEHICLES DRIVING IN AND OUT OF THE PROPOSED | | | DEVELOPMENT WITH VEHICLE DYNAMIC ENVELOPES AND WHEEL | | | PATHS CLEARLY DISTINCT AND DEFINED IN DIFFERENT COLORS | | | 6) PROVIDE A PARKING TABLE SHOWCASING THE NUMBER OF | | | REQUIRED AND PROVIDED PARKING SPACES, INCLUSIVE OF ADA | | | AND BICYCLE ONES | | | 7) PER THE PROPOSED GATE, PLEASE PROVIDE AND SHOWCASE | | | THE 20 FEET SETBACK DISTANCE FROM THE EDGE OF THE ALLEY | | | DRIVING LANE | | | 8) PROVIDE A CONSTRUCTION MANAGEMENT PLAN. PLEASE REFER | | | TO CITY CODE 86-246 FOR DETAILS | | | 9) PLEASE PROVIDE AND SHOWCASE THE DESIGNATED LOADING | | | ZONE, IF REQUIRED BY THE USE TYPE OF THE PROPOSED | | | DEVELOPMENT | | | 10) DUE TO THE INCREASE OF VEHICULAR TRAFFIC AND FOR | | | SAKE OF OPERATIONAL SAFETY, THE ALLEY SHALL BE | | | DESIGNATED ONE-WAY, WITH EASTBOUND-SOUTHBOUND | | | DIRECTIONALITY. PLEASE PROVIDE AND SHOWCASE THE | | | CORRESPONDING SIGNAGE AND PAVEMENT MARKINGS THROUGHOUT | | | THE WHOLE EXTENT OF THE ALLEY | | | | | | VALERIO ORICCHIO | | | CITY TRANSPORTATION ENGINEER | | | 561-494-1092 | | | [email protected] | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
05-10-2023 |
|
|
Cont ID |
|
| Sent By |
cibaven |
Date |
05-10-2023 |
Time |
16:57 |
Rev Time |
0.00 |
| Received By |
cibaven |
Date |
05-10-2023 |
Time |
16:54 |
Sent To |
|
|
| Notes |
| 2023-05-10 16:55:43 | ZONING AND PLANNING | | | PROJECT: 1010 N OLIVE ??? TUTTLE OFFICE | | | CONTACT: CLAUDIA IBAVEN, CITY URBAN DESIGNER, AT | | | 561-822-1402 OR VIA [email protected]. | | | I HAVE REVIEWED THE ABOVE REFERENCED PETITION AND | | | PROVIDE THE FOLLOWING COMMENTS: | | | | | | GENERAL COMMENTS: | | | 1. THE TPS SHOWS TOTAL SQ.FT. AS OFFICE AND DOES NOT | | | INCLUDE THE 1 DU PROPOSED, PLEASE REVISE. TO ACCURATELY | | | REFLECT THE SQ. FT. OF THE PROPOSED DEVELOPMENT. | | | 2. ON PROJECT FAST SHEET, THE RESIDENTIAL GBA PLUS THE | | | NON-RESIDENTIAL GBA DOES NOT TOTAL THE AMOUNT ON THE | | | TOTAL PROJECT GBA PROVIDED ON THE SP-1, PLEASE REVISE. | | | 3. PROVIDE LETTERS FROM ALL PUBLIC UTILITIES CONFIRMING | | | THAT THE PROPOSED PROJECT DOES NOT ENCROACH INTO THEIR | | | EASEMENTS OR OTHERWISE INTERFERE WITH THE PROVISIONS OF | | | THEIR SERVICES. WE RECEIVED AT&T LETTER. | | | 4. FPL WILL NEED TO APPROVE IF IT IS ACCEPTABLE TO HAVE | | | THE WALL AND LANDSCAPING PROPOSED ON THE BACK OF THE | | | PROPERTY WHERE THE 6 FEET EASEMENT IS LOCATED. | | | 5. THE PROJECT IS SUBJECT TO THE CITY OF WPB'S ART LIFE | | | ASSESSMENT. PLEASE CONTACT SYBILLE WELTER, ART IN | | | PUBLIC PLACES COORDINATOR AT 561-822-1521 OR VIA EMAIL | | | AT [email protected]. | | | | | | ZONING DIAGRAMS AND CALCULATIONS | | | 1. THE STAIRS AND ELEVATOR AREAS ON THE 3RD LEVEL WILL | | | NEED TO COUNT AS PART OF THE BUILDING FOOTPRINT ON THE | | | 3RD FLOOR, PLEASE REVISE. | | | 2. ON SHEET SP-1, REQUIREMENT OF FRONT SETBACK IS 25 | | | FEET AND IN THE TABLE IS SAYS THAT THE PROPOSED IS 21 | | | FEET, PLEASE CORRECT. | | | 3. AS PER SEC. 94-106, CULTURAL USES MAY BE PERMITTED | | | BY COMPLYING WITH SPECIAL CONDITIONS, PLEASE REVIEW. | | | THE PROPOSED GALLERY SEEMS TO BE PART OF THE OFFICE AND | | | NOT A SEPARATE USE, SO PLEASE MAKE SURE TO ADD AREA TO | | | THE OFFICE SQ.FT. | | | 4. PLEASE NOTE, THE DEVELOPMENT DOES NOT HAVE REQUIRED | | | OPEN SPACE AND DOES NOT NEED TO COMPLY WITH OPEN SPACE | | | STANDARDS ON SEC. 94-109, TABLE IV-7. PLEASE REMOVE | | | FROM CALCULATIONS AND SP-1 SHEET. | | | | | | LANDSCAPE AND STREETSCAPE | | | 1. PLEASE PROVIDE A TREE DISPOSITION PLAN SHOWING THE | | | LOCATIONS AND SPECIES OF ALL EXISTING TREES AND THEIR | | | DISPOSITION, WHETHER THEY ARE BEING REMOVED OR | | | RELOCATED OR REMAINING. YOU WILL NEED TO PROVIDE AN | | | ARBORIST REPORT FROM AN ISA CERTIFIED ARBORIST | | | JUSTIFYING THE RATING OF TREES AND REASON WHY THEY | | | CANNOT BE RELOCATED. | | | 2. EXISTING TREES SHOWN ON THE LANDSCAPE PLANS DO NOT | | | MATCH SURVEY, PLEASE REVISE. | | | 3. NOTE, ON THE SURVEY THERE ARE OVERHEAD LINES SHOWING | | | ON THE BACK OF THE PROPERTY, WILL THESE BE RELOCATED OR | | | UNDERGROUND, SO YOU ARE ABLE TO PROPOSE THE LANDSCAPE | | | BUFFER? | | | 4. ON SHEET SP-1, PLEASE CLARIFY IF SIDEWALK DIRECTLY | | | ADJACENT TO THE PROPERTY LINE IS CONCRETE AND THAT THE | | | FULL 5 FEET ARE COVERED WITH CONCRETE AND ARE | | | UNINTERRUPTED FOR PEDESTRIAN USE. | | | 5. PLEASE PROVIDE DIMENSIONS ON LANDSCAPE PLANS TO SHOW | | | HOW STREET TREES ARE INSTALLED AT A MAXIMUM OF 30 FEET | | | BETWEEN THEM. | | | 6. STREET TREES SHALL BE A MINIMUM OF 20 FEET IN | | | HEIGHT, AND HAVE A MINIMUM OF EIGHT FEET CLEAR TRUNK, | | | THE PROPOSED SILVER BUTTON WOOD DOES NOT MEET THE | | | REQUIREMENTS. | | | 7. PER SEC. 94-113 (D)(4), STREET TREES SHALL BE | | | PLANTING WITHIN PLANNING BEDS WITH A 4 FEET WIDTH. IN | | | ADDITION, PLANTING GRATES SHOULD HAVE SHRUBS OR | | | GROUNDCOVERS AS APPROPRIATE. THE LANDSCAPE PLANS SHOW | | | TREES ON SIDEWALK PAVERS WITH NO PLANTING BEDS. | | | 8. PER SEC. 94-113, ALL LANDSCAPED AREAS AND PLANT | | | MATERIALS WITHIN OR ADJACENT TO VEHICULAR USE AREAS | | | SHALL BE PROTECTED FROM VEHICULAR ENCROACHMENT BY WHEEL | | | STOPS, CURBS, OR OTHER SIMILAR DEVICES. | | | 9. PER SEC. 94-113 (G), AS NONRESIDENTIAL USE ADJOINING | | | RESIDENTIAL PROPERTY WILL NEED TO PROVIDE A LANDSCAPE | | | BUFFER AND SCREEN WALL, PLEASE CLARIFY HOW THIS | | | REQUIREMENT WILL BE MET IF AN EASEMENT IS LOCATED AT | | | THE REAR AREA. NOTE, ON THE LANDSCAPE BUFFER WILL NEED | | | TO HAVE SHADE TREES PLANTED AT 30-FOOT INTERVALS. | | | 10. PLEASE ADD UTILITY LINES TO LANDSCAPE PLANS. | | | 11. PLEASE NOTE ALL STREET TREES AND LANDSCAPED AREAS | | | WITHIN MINIMUM REQUIRED SETBACK AND THE RIGHT-OF-WAY | | | SHALL HAVE IRRIGATION PROVIDED FROM THE ADJACENT | | | PROPERTY, AS PROVIDED IN THE APPROVED SITE PLAN OR | | | APPROVED LANDSCAPE PLAN. | | | 12. NOTE, THE PROPERTY OWNER AND THEIR SUCCESSORS OR | | | ASSIGNS SHALL BE RESPONSIBLE FOR THE INSTALLATION AND | | | MAINTENANCE OF LANDSCAPING, TREE GRATES, STRUCTURAL | | | SOIL AND IRRIGATION, AS PROVIDED IN THE APPROVED SITE | | | PLAN OR APPROVED LANDSCAPE PLAN. A MAINTENANCE | | | AGREEMENT WITH THE CITY SHALL BE REQUIRED. | | | | | | PARKING | | | 1. PLEASE CLARIFY IF THE PROPOSED DEVELOPMENT WILL HAVE | | | BOTH USES (RESIDENTIAL AND OFFICE) OCCUPIED BY A COMMON | | | OWNER OR TENANT AS PER SEC. 94-109, LIVE/WORK | | | DEFINITION. IF SO, PARKING REQUIREMENTS ON SEC. 94-111, | | | TABLE IV-9 WILL NEED TO BE MEET THE MINIMUM | | | REQUIREMENTS OF 1 PER 1,000 SQ.FT. FOR LIVE/WORK USE. | | | IF NOT, THEN PARKING REQUIREMENT WILL BE 1 PER UNIT FOR | | | RESIDENTIAL AND 1 PER 1,000SQ.FT. FOR OFFICE. | | | 2. PLEASE REVISE PARKING ASSOCIATE WITH CULTURAL USE. | | | SEE COMMENT ON ZONING DIAGRAMS AND CALCULATIONS SECTION | | | ABOVE. | | | 3. PLEASE NOTE, YOU DO NOT NEED TO COUNT THE ON-STREET | | | PARKING SPACE AS PART OF YOUR REQUIRED PARKING IF YOU | | | MEET THE MINIMUM REQUIRED PARKING. IF EXISTING | | | ON-STREET PARKING SPACES WILL BE COUNTED TOWARD | | | REQUIRED PARKING, THEN THE CITY PARKING ADMINISTRATOR | | | AND THE CITY TRAFFIC ENGINEER WILL NEED TO APPROVE IT. | | | 4. PLEASE PROVIDE APPROPRIATE STRIPING TO DELINEATE AND | | | DIFFERENTIATE THE ADA AND STANDARD PARKING SPACES | | | FRONTING THE ALLEY. | | | 5. ON SHEET C2.3, A 'TYPE D CURB' IS SHOWN ADJACENT TO | | | PARKING SPACES ON THE ALLEY AND SEEMS TO GO ALL THE WAY | | | EAST TO WHERE THE SLIDING GATE BEGINS, YET ON LANDSCAPE | | | AND ARCH PLANS THERE IS A 4 FEET HIGH CONCRETE WALL | | | PROPOSED. PLEASE REVISE AND MAKE SURE ALL PLANS ARE | | | CONSISTENT IN DESIGN. NOTE, ARCH PLANS DO NOT SHOW CURB | | | IN FRONT OF THE ADA PARKING SPACE. | | | 6. PER SEC. 94-111, IN THOSE CASES WHERE THE SIDE OF | | | ANY STALL IS ADJACENT TO A WALL, FENCE, BUILDING, OR | | | OTHER PHYSICAL OBSTRUCTION, THE STALL WIDTHS SHALL BE | | | INCREASED BY A MINIMUM OF ONE FOOT. WHERE THERE IS AN | | | OBSTRUCTION ON BOTH SIDES OF THE STALL, THE STALL | | | WIDTHS SHALL BE INCREASED BY A MINIMUM OF TWO FEET. THE | | | PARKING SPACES ADJACENT TO THE ALLEY SEEMS TO BE TOO | | | CLOSE TO WALLS, PLEASE REVISE. | | | | | | OTHER COMMENTS: | | | PLEASE NOTE, AS PER SEC. 94-54 (A)(1), THE APPLICANT | | | SHALL ADDRESS ANY COMMENTS OF THE PPRC AND SUBMIT A | | | REVISED APPLICATION WITHIN 60 DAYS OF THE MEETING | | | SCHEDULED ON 1/12/2023. FAILURE TO MAKE THE REQUIRED | | | SUBMITTALS WITHIN THE 60-DAY DEADLINE WILL DEEM THE | | | APPLICATION AS WITHDRAWN. AT LEAST 15 DAYS PRIOR TO THE | | | EXPIRATION OF THE 60-DAY REVISION PERIOD, THE APPLICANT | | | MAY REQUEST A 30-DAY EXTENSION. NO FURTHER EXTENSION | | | REQUEST IS PERMITTED. COMMENTS RELATING TO REVISED | | | APPLICATIONS SHALL BE ADDRESSED WITHIN 30 DAYS OF THE | | | DATE OF SUCH COMMENTS. | | | WHEN RESUBMITTING, WRITTEN RESPONSES TO COMMENTS NEED | | | TO BE PROVIDED AS WELL AS A MINIMUM OF TWO (2) PAPER | | | COPIES AND AN ELECTRONIC COPY IN .PNG/.PDF FORMAT OF | | | ALL PLANS AND ALL DOCUMENTATION REQUIRED IN THE | | | APPLICATION. PLEASE NOTE THAT CHANGES ON THE | | | RESUBMITTED PLANS OR THE SUBMITTAL OF INFORMATION/PLANS | | | TO ADDRESS THE COMMENTS MAY RESULT IN ADDITIONAL | | | COMMENTS. | | | | | | PLEASE NOTE THAT YOU WILL BE PERMITTED ONE (1) | | | RESUBMITTAL AT NO ADDITIONAL COST. IF PREVIOUSLY ISSUED | | | COMMENTS CONTINUE TO NOT BE SUFFICIENTLY ADDRESSED, THE | | | APPLICANT WILL BE ASSESSED A RESUBMITTAL FEE. SUCH FEE | | | WILL BE 20% OF THE ORIGINAL APPLICATION FEE. | | | | | | --END OF COMMENTS--- | | | |
|
|
| |
Print |
|