Plan Review Details - Project Z23040020
| Plan Review Stops For Project Z23040020 |
| Review Stop |
AIPP |
ART IN PUBLIC PLACES |
| Rev No |
1 |
Status |
N |
Date |
07-13-2023 |
|
|
Cont ID |
|
| Sent By |
swelter |
Date |
07-13-2023 |
Time |
09:33 |
Rev Time |
0.00 |
| Received By |
swelter |
Date |
07-13-2023 |
Time |
09:34 |
Sent To |
|
|
| Notes |
| 2023-07-13 09:34:41 | PROJECT IS EXEMPT FROM PUBLIC ART REQUIRMENT DUE TO THE | | | FOLLOWING: | | | THE LEGACY @ 45TH STREET AS PROPOSED IS A 100% | | | AFFORDABLE HOUSING RENTAL DEVELOPMENT. | | | THE CITY HAS MADE A CONDITIONAL COMMITMENT TO AWARD | | | FEDERAL FUNDING TO THE PROJECT TO BENEFIT HOUSEHOLDS AT | | | OR BELOW 80% AMI. | | | | | | FURTHER QUESTIONS CONTACT SYBILLE WELTER | | | [email protected] OR 561.822.1521 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
07-12-2023 |
|
|
Cont ID |
|
| Sent By |
rbrown |
Date |
07-12-2023 |
Time |
20:09 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
07-12-2023 |
Time |
20:09 |
Sent To |
|
|
| Notes |
| 2023-07-12 20:12:01 | DEVELOPMENT SERVICES DEPARTMENT, BUILDING DIVISION, | | | COMMENTS: | | | | | | 1. THIS REVIEW IS A CURSORY REVIEW AS IT RELATES TO THE | | | SITE. IT IS NOT A REVIEW FOR FULL COMPLIANCE WITH | | | FLORIDA BUILDING CODE. THE FOLLOWING COMMENTS ARE TO BE | | | ADDRESSED FOR THE BUILDING PERMIT APPLICATION. | | | | | | 2. DEMOLITION OF THE EXISTING BUILDING. AN ASBESTOS | | | SURVEY SHALL BE PERFORMED AND AN ASBESTOS ABATEMENT | | | REPORT SUBMITTED TO THE HEALTH DEPARTMENT PALM BEACH | | | COUNTY OFFICE. CONTACT ALEX ORTEGA AT (561) 837-5963, | | | OR BY EMAIL: [email protected] | | | | | | 3. ELECTRIC VEHICLE CHARGING STATION. IF ELECTRIC | | | VEHICLE (EV) CHARGING STATIONS ARE PROVIDED AT LEAST 1 | | | IN 25 MUST COMPLY WITH ACCESSIBLE PARKING SPACE | | | REQUIREMENTS. | | | | | | 4. BUILDING SIZE. WHEN SUBMITTED FOR BUILDING PERMIT, | | | THE PLANS SHALL SHOW THAT THE TYPE OF CONSTRUCTION FOR | | | THE BUILDINGS WILL BE IN ACCORDANCE WITH THE HEIGHT, | | | AREA AND OCCUPANCY LIMITATIONS IN CHAPTER 5 OF THE | | | FLORIDA BUILDING CODE. | | | | | | 5. SEPARATE PERMITS REQUIRED. ALL APPLICABLE PERMITS | | | AND SUB-PERMITS MUST BE OBTAINED BEFORE COMMENCING THE | | | WORK. SEPARATE PERMITS, PLANS AND FEES, ARE REQUIRED | | | FOR SIGNS, SWIMMING POOLS AND SPAS, GAS SYSTEMS, | | | GENERATORS, FIRE ALARM SYSTEMS, FIRE SPRINKLER AND | | | OTHER FIRE SUPPRESSION SYSTEMS, BACKFLOW PREVENTERS, | | | GREASE INTERCEPTORS, SITE LIGHTING, SITE LANDSCAPE, | | | SITE IRRIGATION, ETC. | | | | | | 6. CONTRACTOR VEHICLE PARKING. PROPERTY OWNER AND | | | CONTRACTOR SHALL MAKE ARRANGEMENTS FOR PARKING OF | | | CONTRACTOR VEHICLES TO MINIMIZE THE IMPACT ON ALL | | | NEIGHBORING PROPERTIES. THE CONTRACTOR SHALL SUBMIT A | | | CONSTRUCTION PARKING PLAN TO THE ENGINEERING SERVICES | | | DEPARTMENT. | | | | | | 7. PROTECTION OF NEIGHBORING PROPERTY. PROPERTY OWNER | | | AND CONTRACTOR SHALL PROTECT ALL NEIGHBORING PROPERTY, | | | INCLUDING VEHICLES, FROM DAMAGE OR DIRT CAUSED BY THE | | | CONSTRUCTION, AND SHALL NOTIFY THE OCCUPANTS OF | | | NEIGHBORING PROPERTIES ABOUT ALL STAGES OF CONSTRUCTION | | | THAT MAY AFFECT THE USE OF THEIR PROPERTY. | | | | | | 8. BUILDING ADDRESS. EACH SEPARATE BUILDING, AND UNIT | | | WITH AN INDEPENDENT ENTRANCE FROM THE STREET, SHALL | | | HAVE A SEPARATE ADDRESS ASSIGNED BASED ON THE LOCATION | | | OF THE BUILDING ENTRANCE. FOR STREET ADDRESSING, | | | CONTACT CAROLINE PUELL, ADDRESSING COORDINATOR, AT | | | (561) 805 6659, OR BY EMAIL: [email protected] | | | | | | | | | ROBERT BROWN | | | BUILDING OFFICIAL | | | TEL: 561 805 6652 | | | EMAIL: [email protected] | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
05-10-2023 |
|
|
Cont ID |
|
| Sent By |
rbrown |
Date |
05-10-2023 |
Time |
20:47 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
05-10-2023 |
Time |
20:47 |
Sent To |
|
|
| Notes |
| 2023-05-10 20:51:28 | DEVELOPMENT SERVICES DEPARTMENT, BUILDING DIVISION, | | | COMMENTS: | | | | | | AS OF 5/10/23, INSUFFICIENT PLANS HAVE BEEN SUBMITTED | | | FOR A MEANINGFUL REVIEW. NO ARCHITECTURAL PLANS HAVE | | | BEEN SUBMITTED. THE SITE PLAN DOES NOT MAKE IT CLEARS | | | AS TO WHAT IS THE FRONT WHAT IS THE REAR OF THE | | | BUILDINGS. ARE THE WHEELCHAIR ACCESSIBLE RAMPS ONLY | | | GOING TO THE REAR OF THE BUILDINGS? NEED MORE PLANS AND | | | INFORMATION IN ORDER TO COMPLETE A REVIEW. | | | | | | ROBERT BROWN | | | BUILDING OFFICIAL | | | TEL: 561 805 6652 | | | EMAIL: [email protected] | | | |
|
|
| Review Stop |
ENG - PPRC |
ENGINEERING - PPRC |
| Rev No |
2 |
Status |
F |
Date |
07-07-2023 |
|
|
Cont ID |
|
| Sent By |
lquinone |
Date |
07-07-2023 |
Time |
14:29 |
Rev Time |
0.00 |
| Received By |
lquinone |
Date |
07-07-2023 |
Time |
14:29 |
Sent To |
|
|
| Notes |
| 2023-07-07 14:30:31 | | | | 1. SHOW AND LABEL ANY EXISTING OR PROPOSED WATER | | | SERVICES AND WATER METERS, ALONG WITH WHAT IS HAPPENING | | | TO THEM- WATER MAIN INFORMATION IS NOT SHOWN ON SP-010 | | | 2. SHOW EXISTING AND PROPOSED DEDICATED UTILITY | | | EASEMENTS TO ALLOW ACCESS FOR CITY PERSONNEL TO | | | PROPOSED UTILITY WATER METERS. VERIFY THAT THERE ARE NO | | | STRUCTURES WITHIN THE EASEMENT- EASEMENTS CAN???T BE | | | FOUND ON PLANS | | | 3. PROVIDE ENLARGED VIEW ON PLANS OF PROPOSED LOCATION | | | OF WATER METER AND BACKFLOW PREVENTION. | | | 4. PROVIDE PROFILE AND CLEARANCES BETWEEN WATER, SEWER | | | AND STORM LINES PER CITY OF WEST PALM BEACH STANDARD | | | DETAIL GN-2 SERIES, AT ALL UTILITY CROSSINGS. PLEASE | | | INCLUDE FIBER OPTIC, ELECTRIC, GAS, AND CABLEVISION & | | | TELECOMMUNICATION FACILITIES INCLUDING PIPE SIZE AND | | | MATERIAL LOCATED IN THE RIGHT-OF-WAY. | | | 5. SUBMIT COMPLETED LOS ANALYSIS SUMMARY TABLE DIRECTLY | | | TO ENGINEERING (SHEET 33 OF CITY OF WPB DEVELOPMENT | | | APPLICATION). PROVIDE CALCULATIONS ON PLANS OF EXISTING | | | PROPOSED DEMANDS FOR WATER & SEWER (AVERAGE, MAXIMUM | | | AND PEAK) AND FIRE FLOW DEMANDS. CALCULATIONS SHALL BE | | | PER FAC 64E-6 FOR SEWER AND PER FAC 64-E.008 FOR WATER. | | | 6. PROVIDE CCTV VIDEO OF EXISTING SANITARY SEWER ALONG | | | ENTIRE PROJECT FRONTAGE (CONDITION OF SITE PLAN | | | APPROVAL) | | | 7. ADD NOTE TO PLANS SPECIFYING CITY???S DOWNSTREAM | | | LIFT STATION NUMBER. | | | | | | |
|
|
| Review Stop |
ENG - PPRC |
ENGINEERING - PPRC |
| Rev No |
1 |
Status |
F |
Date |
05-01-2023 |
|
|
Cont ID |
|
| Sent By |
lquinone |
Date |
05-01-2023 |
Time |
13:52 |
Rev Time |
0.00 |
| Received By |
lquinone |
Date |
05-01-2023 |
Time |
13:51 |
Sent To |
|
|
| Notes |
| 2023-05-01 13:52:20 | Z23040020 ??? SUBMITTAL COMMENTS ??? 1ST REVIEW | | | | | | COMMENTS FROM LINDA M. QUINONES-CINTRON, PROJECT | | | COORDINATOR, ENGINEERING SERVICES AT 561-494-1085 | | | [email protected] | | | GENERAL: | | | O PLEASE RESPOND TO ALL COMMENTS IN WRITING, AND | | | INCLUDE PROJECT NAME, ADDRESS AND PERMIT NUMBER | | | (Z-XXXXXXXX). | | | O THE CITY OF WEST PALM BEACH HAS A NUMBER OF | | | REGULATIONS AND PERMIT REQUIREMENTS WHICH DIRECTLY | | | AFFECT THE DEVELOPMENT AND INSTALLATION OF WATER AND | | | WASTEWATER UTILITIES WITHIN THE CITY. PLEASE SEE | | | DEVELOPMENT PERMIT SUBMITTAL REQUIREMENTS AT THE LINK | | | BELOW: | | | A. HTTP://WPB.ORG/CMSPAGES/GETAMAZONFILE.ASPX?PATH=~\WP | | | B_WEBSITE\MEDIA\ENGINEERING\DEVELOPMENT-APPLICATION-FUL | | | L-PACKAGE_2016.PDF&HASH=7BD4DD7EB6115181D8C5977BCC02A97 | | | B1960045731D3658206F27451722716EF | | | B. THIS AND OTHER RELATED ENGINEERING DOCUMENTS CAN BE | | | FOUND HERE: | | | HTTP://WPB.ORG/DEPARTMENTS/ENGINEERING-PUBLIC-WORKS/FOR | | | MS,-PERMITS-APPLICATIONS | | | C. ALSO SEE: CODE OF ORDINANCES, CITY OF WEST PALM | | | BEACH, FLORIDA, CODIFIED THROUGH ORD. NO. 4183-08, | | | ADOPTED SEPT. 22, 2008. (SUPPLEMENT NO. 18) | | | CHAPTER 90 UTILITIES, ARTICLE I. IN GENERAL, | | | SEC. 90-7. POLICY REGARDING EXTENSION OF WATER OR SEWER | | | SERVICE FACILITIES OF THE CITY. | | | THE WATER AND WASTEWATER SERVICE AGREEMENTS AND THE | | | CONSTRUCTION PERMITS ADDRESS RESERVATION OF CAPACITY | | | BASED ON USAGE, METER SIZE AND FEES, DESIGN STANDARDS, | | | BACKFLOW PREVENTION, FIRE SERVICE AND IRRIGATION. | | | O AS OF DECEMBER 20, 2015, THE CITY OF WEST PALM BEACH | | | CROSS-CONNECTION CONTROL MANUAL HAS BEEN REVISED, | | | STATING "ALL BACKFLOW DEVICES MUST BE LEAD-FREE". FOR | | | MORE INFORMATION, REFER TO THE LINK BELOW: | | | A. HTTP://WPB.ORG/DEPARTMENTS/PUBLIC-UTILITIES/FORMS-PU | | | BLICATIONS/BACKFLOW-CROSS-CONNECTION- CONTROL-MANUAL | | | O PLEASE SUBMIT A FORMAL AS-BUILT REQUEST FOR ALL CITY | | | OF WEST PALM BEACH-OWNED UTILITIES WITHIN THE PUBLIC | | | RIGHT OF WAY FOR THE ENTIRE EXTENT OF THE LIMITS OF | | | YOUR PROJECT. IDENTIFY TYPE OF UTILITY, LOCATION, PIPE | | | MATERIAL, AGE AND SIZE. PLEASE CONTACT JANICE TARBILL | | | IN THE WPB ENGINEERING SERVICES DEPARTMENT AT | | | [email protected] OR 561-494-1079 FOR FURTHER | | | ASSISTANCE. NOTE THAT FIELD RECORDS ARE FOR INFORMATION | | | ONLY. FIELD VERIFY UTILITY LOCATIONS USING FIELD | | | SURVEY, POT-HOLING, SOFT DIGS ETC. | | | O PROVIDE EXISTING AND PROPOSED PERVIOUS AND IMPERVIOUS | | | DATA. | | | | | | BACKFLOW ASSEMBLY AND METERS: | | | O SHOW AND LABEL ANY EXISTING OR PROPOSED WATER | | | SERVICES AND WATER METERS, ALONG WITH WHAT IS HAPPENING | | | TO THEM. | | | O SHOW EXISTING AND PROPOSED DEDICATED UTILITY | | | EASEMENTS TO ALLOW ACCESS FOR CITY PERSONNEL TO | | | PROPOSED UTILITY WATER METERS. VERIFY THAT THERE ARE NO | | | STRUCTURES WITHIN EASEMENT. | | | O PROVIDE ENLARGED VIEW ON PLANS OF PROPOSED LOCATION | | | OF WATER METER AND BACKFLOW | | | PREVENTION. | | | O BACKFLOWS SHALL BE INSTALLED ON PRIVATE PROPERTY | | | OUTSIDE OF EASEMENTS AND RIGHTS OF WAY. DOMESTIC WATER | | | METERS SHALL BE INSTALLED IMMEDIATELY ADJACENT TO | | | PROPERTY LINE. 3 INCH AND LARGER WATER METERS SHALL BE | | | INSTALLED ABOVE-GROUND ONLY. | | | O CALLOUT DOMESTIC BACKFLOW PREVENTER AS RPPA (MAKE | | | NOTE USC APPROVED) AND FIRE BACKFLOW PREVENTER AS DCDA. | | | | | | WATER/WASTEWATER PLAN: | | | O PLANS SHALL SHOW EXISTING AND PROPOSED LOCATIONS AND | | | DIMENSIONS OF ALL WATER, STORMWATER, AND SANITARY AND | | | SEWER LINES AND CLEANOUTS, INCLUDING STUBS TO EACH | | | PROPERTY LINE FOR WATER AND SANITARY SEWERS, THE MAKE | | | AND MODEL OF ALL VALVES, POTABLE AND IRRIGATION METERS, | | | BACKFLOWS, FIRE HYDRANTS AND FDCS, AND OTHER DEVICES TO | | | BE INSTALLED ON THE SYSTEM, CATCH BASINS, CULVERTS, | | | DITCHES INCLUDING GRADES, PIPES SIZES, MATERIALS, | | | ELEVATIONS, ASSUMPTIONS, CALCULATIONS, INVERT | | | ELEVATIONS FOR ALL INLETS AND MANHOLES AND PROFILES OF | | | SANITARY SEWER LINES. | | | O GATE VALVE BOXES SHALL NOT BE INSTALLED IN CURB OR | | | SIDEWALK. ALL AVAILABLE ELEVATION SHALL BE SHOWN ON THE | | | PROFILE VIEW. | | | O DIRECTION OF FLOW SHALL BE SHOWN ON PLAN VIEW FOR ALL | | | SANITARY AND STORM SEWERS. | | | O SHOW SLOPE % ON ALL SANITARY LINES AND CALL OUT | | | MATERIAL. | | | O PLAN VIEW SHALL SHOW ALL EXISTING AND PROPOSED | | | UNDERGROUND UTILITY LAYOUT, INCLUDING FIBER OPTIC, | | | ELECTRIC, GAS, AND CABLEVISION & TELECOMMUNICATION | | | FACILITIES INCLUDING PIPE SIZE AND MATERIAL LOCATED IN | | | THE RIGHT-OF-WAY. | | | O PROVIDE PROFILE AND CLEARANCES BETWEEN WATER, SEWER | | | AND STORM LINES PER CITY OF WEST PALM BEACH STANDARD | | | DETAIL GN-2 SERIES, AT ALL UTILITY CROSSINGS. PLEASE | | | INCLUDE FIBER OPTIC, ELECTRIC, GAS, AND CABLEVISION & | | | TELECOMMUNICATION FACILITIES INCLUDING PIPE SIZE AND | | | MATERIAL LOCATED IN THE RIGHT-OF-WAY. | | | O SUBMIT COMPLETED LOS ANALYSIS SUMMARY TABLE DIRECTLY | | | TO ENGINEERING (SHEET 33 OF CITY OF WPB DEVELOPMENT | | | APPLICATION). PROVIDE CALCULATIONS ON PLANS OF EXISTING | | | AND PROPOSED DEMANDS FOR WATER & SEWER (AVERAGE, | | | MAXIMUM AND PEAK) AND FIRE FLOW DEMANDS. CALCULATIONS | | | SHALL BE PER FAC 64E-6 FOR SEWER AND PER FAC 64-E.008 | | | FOR WATER. | | | O PROVIDE FIRE FLOW TEST DATA. | | | O PROVIDE CCTV VIDEO OF EXISTING SANITARY SEWER AND | | | STORMWATER INFRASTRUCTURE ALONG ENTIRE PROJECT FRONTAGE | | | (CONDITION OF SITE PLAN APPROVAL). | | | O CUT AND CAP UTILITIES NOT IN USE AND REMOVE ANY | | | ABANDONED UTILITY LINES LARGER THAN 2 INCHES FROM CITY | | | ROW. | | | O WHEN PROPOSED, WATER MAINS IN CITY RIGHT OF WAY SHALL | | | BE MADE OF DUCTILE IRON PIPE (NOT PVC) AND SPECIFY | | | PROPOSED LENGTH IN FEET. | | | O CHECK TO SEE IF FDEP FORMS FOR PROPOSED SANITARY | | | SEWER ARE REQUIRED. | | | O PROVIDE CLEANOUTS FOR PROPOSED SANITARY LINE ONSITE | | | JUST INSIDE PROPERTY LINE, AT JOINTS AND EVERY 75 FEET. | | | O ADD NOTE TO PLANS SPECIFYING CITY???S DOWNSTREAM LIFT | | | STATION NUMBER. | | | O PROVIDE ONSITE CLEANOUTS NEAR PROPERTY LINE FOR | | | PROPOSED SANITARY LATERALS. | | | O LABEL WATER LINES AS PRIVATE WHERE APPLICABLE. | | | O PLEASE SHOW AND LABEL EXISTING AND PROPOSED GREASE | | | TRAPS (IF ANY). | | | O PER CITY STANDARDS MAINTAIN MINIMUM DISTANCE BETWEEN | | | OUTSIDE DIAMETER OF CITY PIPE AND ROOT BARRIER. | | | | | | FORMAL ENGINEERING REVIEW: | | | O FOR FORMAL ENGINEERING SUBMITTAL, SFWMD ERP AND NPDES | | | NOI REQUIREMENTS WILL BE ENFORCED. | | | - AN NOI IS REQUIRED FOR PROJECTS THAT: | | | - 1) DISTURB ONE OF MORE ACRES OF LAND OR DISTURB LESS | | | THAN ON ACRE OF LAND BUT ARE PART OF A COMMON PLAN OF | | | DEVELOPMENT OR SALE; | | | - 2) DISCHARGE STORMWATER TO SURFACE WATERS OF THE | | | STATE OR TO SURFACE WATERS OF THE STATE THROUGH A | | | MUNICIPAL SEPARATE STORM SEWER SYSTEM (MS4). | | | - THE SFWMD ERP CAN BE OBTAINED THROUGH A 10-2 SELF | | | CERTIFICATION THROUGH FDEP OR AN ERP APPLICATION | | | THROUGH SFWMD. EITHER WAY, THE DEVELOPER/ENGINEER SHALL | | | SUBMIT A COPY OF THE ERP PERMIT OR FDEP ACKNOWLEDGEMENT | | | OF THE 10-2 CERTIFICATION. | | | O FOR FORMAL ENGINEERING SUBMITTAL, PLEASE PROVIDE | | | EASEMENT FOR PLACEMENT OF PROPOSED WATER METERS. | | | O FOR FORMAL ENGINEERING SUBMITTAL, PROVIDE PROFILES OF | | | WATER AND SEWER AND SHOW ANY CROSSINGS/CONFLICTS. | | | O FOR FORMAL ENGINEERING SUBMITTAL, WHEN SUBMITTING | | | APPROVED MATERIALS LIST, PLEASE PROVIDE MATERIAL/CUT | | | SHEETS FOR ALL PROPOSED BACKFLOW DEVICES SHOWING | | | SPECIFIC MODEL NUMBER AND SPECIFYING USC APPROVED | | | LEAD-FREE DESIGN. | | | O FOR FORMAL ENGINEERING SUBMITTAL, IF SANITARY LINES | | | ARE PROPOSED IN ROW PLEASE SHOW ADJACENT SANITARY | | | LATERAL LOCATIONS AND SHOW ADDRESSES OF ADJACENT | | | PARCELS. | | | O FOR FORMAL ENGINEERING SUBMITTAL, IF WATER LINES ARE | | | BEING REPLACED IN ROW, SHOW ADJACENT PARCEL ADDRESSES. | | | O FOR FORMAL ENGINEERING SUBMITTAL, ADD NOTE TO PROVIDE | | | 50 FT. PAVEMENT RESTORATION TRANSITION ON EACH SIDE OF | | | PROPOSED TRENCH IN CITY MAINTAINED ROADWAY AREAS PER | | | CITY OF WPB STANDARD DETAIL GC-8. | | | O FOR FORMAL ENGINEERING SUBMITTAL, PLEASE PROVIDE | | | CALCULATIONS OF PERVIOUS AND IMPERVIOUS AREAS FOR | | | PROPOSED IMPROVED AREAS. | | | | | | QUESTIONS AND COORDINATION CONTACTS: | | | O MARK HURLEY, FIELD CUSTOMER SERVICE SUPERVISOR WITH | | | CITY OF WPB PUBLIC UTILITIES, REGARDING PLACEMENT OF | | | BACKFLOW DEVICES AND WATER METERS. CONTACT HIM AT | | | 561-822-2262 OR [email protected] | | | O COMMENTS FROM MIKE TECHNOW, PUB. UTILITIES ENGINEER, | | | [email protected], 561-494-1047: | | | O COMMENTS FROM RICKY ELIZONDO, PUB. UTILITIES PLANS | | | EXAMINER, [email protected] , 561-494-1101: | | | O COMMENTS FROM TRACY WARD, SR. STORMWATER ENGINEER, | | | ENG. SERVICES DEPT. AT 561-494-1120 OR [email protected] | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
06-06-2023 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
06-06-2023 |
Time |
09:42 |
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
06-06-2023 |
Time |
09:42 |
Sent To |
|
|
| Notes |
| 2023-06-06 09:43:41 | 2ND REVIEW RESPONSE | | | | | | AFTER A REVIEW OF THE PPRC RESPONSE PACKET FOR THIS | | | PROJECT, THE PREVIOUSLY SUBMITTED FIRE PREVENTION | | | BUREAU COMMENTS APPEAR TO HAVE BEEN ADDRESSED. | | | | | | HOWEVER, THE BUREAU'S APPROVAL OF THIS SUBMITTED | | | PROJECT DOES NOT CONSTITUTE ITS FINAL REVIEW OR | | | APPROVAL. | | | | | | THE BUREAU SHALL REVIEW ALL SUBMITTED BUILDING PLANS AT | | | THE APPROPRIATE TIME AND IN ACCORDANCE WITH THE | | | REQUIREMENTS OF ALL APPLICABLE CODES AND STANDARDS. | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | WEST PALM BEACH FIRE DEPARTMENT | | | 561-804-4709 | | | [email protected] | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
05-05-2023 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
05-05-2023 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
05-05-2023 |
Time |
12:11 |
Sent To |
|
|
| Notes |
| 2023-05-05 12:16:53 | THE FOLLOWING COMMENTS WERE SUBMITTED BY PETER LEDUC, | | | FIRE MARSHAL, BUREAU OF FIRE PREVENTION, WEST PALM | | | BEACH FIRE DEPARTMENT. | | | | | | THIS REVIEW CAN ONLY BE CONSIDERED PRELIMINARY AS THE | | | DRAWINGS THAT WERE REVIEWED WERE NOT COMPLETE. | | | ADDITIONAL COMMENTS CAN BE EXPECTED WHEN FULL DRAWINGS | | | ARE SUBMITTED FOR PERMIT. | | | | | | THE FIRE PREVENTION BUREAU HAS NO OBJECTIONS TO THE | | | PROPOSED PROJECT. THE FOLLOWING COMMENTS ARE INTENDED | | | TO PROVIDE GUIDANCE FOR BUILDING PLAN SUBMITTAL. | | | | | | 1. CONSTRUCTION, DEMOLITION, AND RENOVATION TO COMPLY | | | WITH NFPA 241. EXTRA ATTENTION SHALL BE GIVEN TO THE | | | PERMITTING AND LOCATION OF CONSTRUCTION TRAILERS. A | | | PERMIT IS REQUIRED FOR ANY CONSTRUCTION TRAILER RELATED | | | TO THIS PROJECT. SEPARATION DISTANCES FROM MAIN | | | STRUCTURES AS WELL AS OTHER TRAILERS SHALL BE CLOSELY | | | MONITORED FOR THE REQUIREMENTS OF FIRE SPRINKLER | | | PROTECTION. | | | | | | 2. SITE ACCESS AND EXIT POINTS ARE TO BE CLEARLY | | | IDENTIFIED AND MAINTAINED FOR EMERGENCY VEHICLES DURING | | | ALL CONSTRUCTION ACTIVITIES. | | | | | | 3. THE BUILDING ADDRESS SHALL BE CLEARLY VISIBLE FROM | | | ALL ACCESS ROADWAYS, INCLUDING DURING CONSTRUCTION. | | | ADDRESS NUMBERS SHALL CONTRAST WITH THEIR BACKGROUND | | | AND SHALL NOT BE LESS THAN SIX (6) INCHES IN HEIGHT | | | WITH A ONE (1) INCH STROKE FOR ALL BUILDINGS. | | | | | | 4. DURING CONSTRUCTION, TRASH AND DEBRIS IS TO BE | | | REMOVED FROM THE SITE DAILY OR MORE OFTEN TO REDUCE THE | | | ACCUMULATION OF POTENTIAL LIFE AND FIRE SAFETY HAZARDS. | | | | | | 5. THE CONSTRUCTION OF THE BUILDING(S) SHALL COMPLY | | | WITH THE 7TH EDITION OF THE FLORIDA FIRE PREVENTION | | | CODE, INCLUDING NFPA 1 & 101, AND ALL ASSOCIATED FIRE | | | CODES. | | | | | | 6. FOR PLAN REVIEW SUBMITTAL, PLEASE INCLUDE THE | | | OCCUPANCY TYPE PER THE FLORIDA FIRE PREVENTION CODE. | | | | | | 7. FOR PLAN REVIEW SUBMITTAL, PLEASE ENSURE THAT A FIRE | | | LOAD CALCULATION IS INCLUDED, AND THAT ADEQUATE WATER | | | SUPPLY IS EXISTING OR WILL BE PROVIDED. | | | | | | 8. ALL EXISTING AND NEW FIRE HYDRANTS PLANNED FOR THIS | | | DEVELOPMENT SHALL BE CLEARLY INDICATED AND IDENTIFIED | | | ON THE PLAN AND CLOSELY COORDINATED WITH THE BUREAU OF | | | FIRE PREVENTION. | | | | | | THE PROPOSED LOCATION OF THE FIRE HYDRANT AND FDC SHALL | | | BE WITHIN 100' OF EACH OTHER AND CLOSELY COORDINATED | | | WITH THE BUREAU OF FIRE PREVENTION. | | | | | | 9. PROVIDE FOR A FIRE SPRINKLER AND/OR FIRE ALARM PER | | | THE APPLICABLE OCCUPANCY CODE. FOR ANY LIFE SAFETY | | | ENGINEERED SYSTEM, I.E FIRE SPRINKLER AND FIRE ALARM, | | | ENSURE THEY COMPLY WITH THE REQUIREMENTS OF F.A.C. 61G | | | AND SUBMITTED WITH THE MASTER PERMIT. | | | | | | 9A. THE LOCATION OF ANY APPLICABLE DDCV AND FIRE LINE | | | LOCATIONS SHALL MEET AND BE INSTALLED PER THE | | | REQUIREMENTS OF NFPA 24 AND SHALL BE COORDINATED WITH | | | THE OFFICE OF FIRE MARSHAL, THE CITY'S ENGINEERS | | | OFFICE, THE LANDSCAPE PLANNER, AND THE CITY'S PLANNING | | | AND ZONING OFFICE. | | | | | | 10. COMPLETE LIFE SAFETY PLANS FOR THE OCCUPANCY SHALL | | | BE PROVIDED THAT ILLUSTRATE OCCUPANT LOADS, TRAVEL | | | DISTANCES, EXIT SEPARATION DISTANCES, COMMON PATHS OF | | | TRAVEL, DEAD-END CORRIDORS, EXIT SIGNS, EMERGENCY | | | LIGHTING, EXITS LEADING TO A PUBLIC WAY, FIRE | | | EXTINGUISHER LOCATIONS, AND ALL FIRE SAFETY FEATURES | | | AND EQUIPMENT. | | | | | | 11. IT IS HIGHLY RECOMMENDED (REQUIRED WITH FIRE | | | SPRINKLER SYSTEM) THAT A KNOX BOX WITH KEYS FOR ENTRY | | | DOOR LOCKS BE PROVIDED FOR 24 HOUR EMERGENCY ACCESS. | | | | | | 12. AREAS OF REFUGE SHALL BE PROVIDED AS REQUIRED PER | | | THE FLORIDA BUILDING CODE AND NFPA 101, CH 7, MEANS OF | | | EGRESS. | | | | | | 12A. ALL ELEVATORS SHALL BE EQUIPPED WITH A REGION 7 | | | KEYWAY SYSTEM 6 OR MORE STORIES PER F.A.C. | | | | | | ALL NEW ELEVATORS SHALL CONFORM TO THE FIRE FIGHTER???S | | | EMERGENCY OPERATIONS REQUIREMENTS OF ASME A17.1/CSA | | | B44, SAFETY CODE FOR ELEVATORS. | | | | | | ANY BUILDING THAT IS MORE THAN THREE STORIES HIGH OR IN | | | WHICH THE VERTICAL DISTANCE BETWEEN THE BOTTOM TERMINAL | | | LANDING AND THE TOP TERMINAL LANDING EXCEEDS 25 FEET | | | MUST BE CONSTRUCTED TO CONTAIN AT LEAST ONE PASSENGER | | | ELEVATOR THAT IS OPERATIONAL AND WILL ACCOMMODATE AN | | | AMBULANCE STRETCHER 76 INCHES LONG AND 24 INCHES WIDE | | | IN THE HORIZONTAL POSITION. | | | | | | 13. TWO-WAY RADIO COMMUNICATIONS ENHANCEMENT SYSTEMS. | | | | | | NFPA 1, CHAPTER 11, BUILDING SERVICES; 11.10 TWO-WAY | | | RADIO ENHANCEMENT SERVICES. | | | 11.10.1 IN ALL NEW AND EXISTING BUILDINGS, MINIMUM | | | RADIO SIGNAL STRENGTH FOR FIRE DEPARTMENT | | | COMMUNICATIONS SHALL BE MAINTAINED AT A LEVEL | | | DETERMINED BY THE AHJ. | | | | | | CONTACT WILL NEED TO BE MADE TO MARK FILLA, PALM BEACH | | | COUNTY PUBLIC SAFETY RADIO SYSTEMS MANAGER, | | | [email protected], 561-233-0837; AS OUR RADIOS OPERATE | | | ON THEIR SYSTEM FOR DETAILED RADIO FREQUENCY AND | | | INSTALLATION INSTRUCTIONS. | | | | | | 14. THE BUREAU'S APPROVAL OF THIS SUBMITTED PROJECT | | | DOES NOT CONSTITUTE ITS FINAL REVIEW OR APPROVAL. | | | | | | 15. THE BUREAU SHALL REVIEW ALL SUBMITTED BUILDING | | | PLANS AT THE APPROPRIATE TIME AND IN ACCORDANCE WITH | | | THE REQUIREMENTS OF ALL APPLICABLE CODES AND STANDARDS. | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
2 |
Status |
F |
Date |
06-26-2023 |
|
|
Cont ID |
|
| Sent By |
kdefranc |
Date |
06-26-2023 |
Time |
12:07 |
Rev Time |
0.00 |
| Received By |
kdefranc |
Date |
06-26-2023 |
Time |
12:05 |
Sent To |
|
|
| Notes |
| 2023-06-26 12:06:41 | FROM: KEVIE DEFRANC, SENIOR PLANNER 561-822-1449 | | | PROJECT: LEGACY AT 45TH STREET Z23040020 | | | JUNE 26, 2023 | | | I HAVE REVIEWED THE ABOVE REFERENCED PETITION, AND | | | PROVIDE THE FOLLOWING COMMENTS: | | | | | | 1. SATISFIED. PER SECTION 94-442(B)(1), PROVIDE | | | LANDSCAPE PLANS SIGNED AND SEALED BY A REGISTERED | | | LANDSCAPE ARCHITECT. | | | | | | 2. SATISFIED. PROVIDE BOTH PHYSICAL HARDCOPIES AND | | | ELECTRONIC COPIES OF THE LANDSCAPE PLANS. | | | | | | 3. SATISFIED. PROVIDE A SEPARATE TREE DISPOSITION PLAN | | | BASED ON A TREE SURVEY. INCLUDE EXISTING PALM AND | | | CANOPY TREES IN THE RIGHT-OF-WAY AND ON ADJACENT | | | PROPERTIES WITHIN 10 FEET OF THE PROPERTY LINE. | | | | | | 4. SATISFIED. PER SECTION 94-443(D)(1), PROVIDE THE | | | PROPOSED LANDSCAPE BUFFER WIDTH DIMENSIONS ON THE | | | LANDSCAPE PLAN (SHEET NO. LP-1). | | | | | | 5. SATISFIED. PROVIDE THE EXISTING AND PROPOSED | | | EASEMENTS ON THE LANDSCAPE PLAN (SHEET NO. LP-1). | | | | | | 6. NOT SATISFIED. PER SECTION 94-442(C)(2)(B), PROVIDE | | | THE OPEN SPACE AREA CALCULATIONS (REQUIRED AND | | | PROPOSED) ON THE LANDSCAPE PLAN (SHEET NO. LP-1). | | | | | | 6/26/23 IN ACCORDANCE WITH SECTION 94-174(B)(6), THE | | | MINIMUM REQUIRED OPEN SPACE AREA FOR PROPERTIES WITHIN | | | THE INDUSTRIAL ZONING DISTRICT IS 40 PERCENT. UPDATE | | | THE CALCULATIONS, ACCORDINGLY. | | | | | | 7. PARTIALLY SATISFIED. PER SECTION 94-442(C)(2)(B), | | | PROVIDE THE LANDSCAPE AREA CALCULATIONS (REQUIRED AND | | | PROPOSED) ON THE LANDSCAPE PLAN (SHEET NO. LP-1). | | | | | | 6/26/23 PROVIDE LENGTH OF EACH BUFFER IN CALCULATIONS. | | | | | | 8. SATISFIED. PER SECTIONS 94-442(C)(2)(B) AND | | | 94-443(D), REVISE THE LANDSCAPE PLAN (SHEET NO. LP-1), | | | ACCORDINGLY, AND PROVIDE THE TREES CALCULATIONS | | | (REQUIRED AND PROPOSED) ON THE LANDSCAPE PLAN (SHEET | | | NO. LP-1). | | | | | | 9. SATISFIED. PER SECTION 94-442(C)(2)(B), AT LEAST ONE | | | SHRUB SHALL BE PLANTED FOR EACH 500 SQUARE FEET OF | | | REQUIRED OPEN SPACE OR PORTION THEREOF. THEREFORE, | | | PROVIDE THE SHRUBS CALCULATIONS (REQUIRED AND PROPOSED) | | | ON THE LANDSCAPE PLAN (SHEET NO. LP-1). | | | | | | 10. SATISFIED. PER SECTION 94-442(C)(2)(B), GRASS AREAS | | | SHALL NOT EXCEED 60 PERCENT OF THE REQUIRED LANDSCAPE | | | AREA. THEREFORE, PROVIDE THE GRASS AREAS CALCULATIONS | | | (REQUIRED AND PROPOSED) ON THE LANDSCAPE PLAN (SHEET | | | NO. LP-1). | | | | | | 11. SATISFIED. PER SECTIONS 94-443(C)(3) AND (4), | | | PROVIDE AN EXHIBIT SHOWING THE PARKING AREA SURFACE | | | CALCULATIONS, PARKING SPACE AREAS AND LANDSCAPE AREAS. | | | PROVIDE THE CALCULATIONS AND SHOW THE ACTUAL PROPOSED | | | INTERIOR LANDSCAPE SQUARE FOOTAGE. | | | | | | 12. NOT SATISFIED. PER SECTION 94-443(C)(3)(A), EACH | | | ROW OF PARKING SPACES SHALL BE TERMINATED BY LANDSCAPED | | | ISLANDS OF NOT LESS THAN EIGHT FEET IN WIDTH AND NOT | | | LESS THAN THE LENGTH OF THE ADJACENT PARKING STALL. | | | EACH LANDSCAPED ISLAND SHALL HAVE A MINIMUM RADIUS OF | | | TWO AND ONE-HALF FEET AT ITS END SO AS TO ALLOW CAR | | | MANEUVERING. EACH LANDSCAPED ISLAND SHALL CONTAIN AT | | | LEAST ONE SHADE OR FLOWERING TREE PER ROW OF PARKING. | | | THEREFORE, REVISE THE LANDSCAPE PLAN (SHEET NO. LP-1), | | | ACCORDINGLY, AND PROVIDE THE DIMENSIONS OF THE PROPOSED | | | TERMINAL LANDSCAPE ISLANDS. IDENTIFY/INDICATE THE | | | REQUESTED VARIANCE RELATING TO THE TERMINAL LANDSCAPE | | | ISLANDS ON THE LANDSCAPE PLAN (SHEET NO. LP-1), IF THIS | | | IS STILL THE CASE AFTER THE REVISIONS. | | | | | | 6/26/23 IT HAS BEEN IDENTIFIED THAT REQUIRED TERMINAL | | | ISLANDS ARE MISSING. A CANOPY TREE IS REQUIRED FOR ALL | | | ISLANDS. | | | | | | 13. NOT SATISFIED. PROVIDE LOCATIONS AND SCREENING FOR | | | ALL SPECIAL UTILITY STRUCTURES AND ABOVE GROUND | | | APPURTENANCES ON THE LANDSCAPE PLAN (SHEET NO. LP-1). | | | | | | 6/26/23 SHOW AND CALL OUT ABOVE GROUND EQUIPMENT. | | | | | | 14. SATISFIED. PROVIDE THE DELINEATION OF IRRIGATION | | | COVERAGE, SENSORS AND HIGH, MEDIUM AND LOW ZONES OF | | | WATER USAGE. INCLUDE A STATEMENT THAT ALL LANDSCAPE | | | AREAS, EXCLUDING THOSE AREAS WITH NATIVE NONINVASIVE | | | PLANTS, WILL BE PROVIDED WITH PERMANENT AUTOMATIC | | | IRRIGATION, INCLUDING ADJACENT RIGHTS???OF???WAY. | | | |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
1 |
Status |
F |
Date |
05-09-2023 |
|
|
Cont ID |
|
| Sent By |
kdefranc |
Date |
05-09-2023 |
Time |
14:48 |
Rev Time |
0.00 |
| Received By |
kdefranc |
Date |
05-09-2023 |
Time |
14:46 |
Sent To |
|
|
| Notes |
| 2023-05-09 14:47:51 | FROM: KEVIE DEFRANC, SENIOR PLANNER 561-822-1449 | | | PROJECT: LEGACY AT 45TH STREET Z23040020 | | | MAY 9, 2023 | | | I HAVE REVIEWED THE ABOVE REFERENCED PETITION, AND | | | PROVIDE THE FOLLOWING COMMENTS: | | | | | | 1. PER SECTION 94-442(B)(1), PROVIDE LANDSCAPE PLANS | | | SIGNED AND SEALED BY A REGISTERED LANDSCAPE ARCHITECT. | | | | | | 2. PROVIDE BOTH PHYSICAL HARDCOPIES AND ELECTRONIC | | | COPIES OF THE LANDSCAPE PLANS. | | | | | | 3. PROVIDE A SEPARATE TREE DISPOSITION PLAN BASED ON A | | | TREE SURVEY. INCLUDE EXISTING PALM AND CANOPY TREES IN | | | THE RIGHT-OF-WAY AND ON ADJACENT PROPERTIES WITHIN 10 | | | FEET OF THE PROPERTY LINE. | | | | | | 4. PER SECTION 94-443(D)(1), PROVIDE THE PROPOSED | | | LANDSCAPE BUFFER WIDTH DIMENSIONS ON THE LANDSCAPE PLAN | | | (SHEET NO. LP-1). | | | | | | 5. PROVIDE THE EXISTING AND PROPOSED EASEMENTS ON THE | | | LANDSCAPE PLAN (SHEET NO. LP-1). | | | | | | 6. PER SECTION 94-442(C)(2)(B), PROVIDE THE OPEN SPACE | | | AREA CALCULATIONS (REQUIRED AND PROPOSED) ON THE | | | LANDSCAPE PLAN (SHEET NO. LP-1). | | | | | | 7. PER SECTION 94-442(C)(2)(B), PROVIDE THE LANDSCAPE | | | AREA CALCULATIONS (REQUIRED AND PROPOSED) ON THE | | | LANDSCAPE PLAN (SHEET NO. LP-1). | | | | | | 8. PER SECTIONS 94-442(C)(2)(B) AND 94-443(D), REVISE | | | THE LANDSCAPE PLAN (SHEET NO. LP-1), ACCORDINGLY, AND | | | PROVIDE THE TREES CALCULATIONS (REQUIRED AND PROPOSED) | | | ON THE LANDSCAPE PLAN (SHEET NO. LP-1). | | | | | | 9. PER SECTION 94-442(C)(2)(B), AT LEAST ONE SHRUB | | | SHALL BE PLANTED FOR EACH 500 SQUARE FEET OF REQUIRED | | | OPEN SPACE OR PORTION THEREOF. THEREFORE, PROVIDE THE | | | SHRUBS CALCULATIONS (REQUIRED AND PROPOSED) ON THE | | | LANDSCAPE PLAN (SHEET NO. LP-1). | | | | | | 10. PER SECTION 94-442(C)(2)(B), GRASS AREAS SHALL NOT | | | EXCEED 60 PERCENT OF THE REQUIRED LANDSCAPE AREA. | | | THEREFORE, PROVIDE THE GRASS AREAS CALCULATIONS | | | (REQUIRED AND PROPOSED) ON THE LANDSCAPE PLAN (SHEET | | | NO. LP-1). | | | | | | 11. PER SECTIONS 94-443(C)(3) AND (4), PROVIDE AN | | | EXHIBIT SHOWING THE PARKING AREA SURFACE CALCULATIONS, | | | PARKING SPACE AREAS AND LANDSCAPE AREAS. PROVIDE THE | | | CALCULATIONS AND SHOW THE ACTUAL PROPOSED INTERIOR | | | LANDSCAPE SQUARE FOOTAGE. | | | | | | 12. PER SECTION 94-443(C)(3)(A), EACH ROW OF PARKING | | | SPACES SHALL BE TERMINATED BY LANDSCAPED ISLANDS OF NOT | | | LESS THAN EIGHT FEET IN WIDTH AND NOT LESS THAN THE | | | LENGTH OF THE ADJACENT PARKING STALL. EACH LANDSCAPED | | | ISLAND SHALL HAVE A MINIMUM RADIUS OF TWO AND ONE-HALF | | | FEET AT ITS END SO AS TO ALLOW CAR MANEUVERING. EACH | | | LANDSCAPED ISLAND SHALL CONTAIN AT LEAST ONE SHADE OR | | | FLOWERING TREE PER ROW OF PARKING. THEREFORE, REVISE | | | THE LANDSCAPE PLAN (SHEET NO. LP-1), ACCORDINGLY, AND | | | PROVIDE THE DIMENSIONS OF THE PROPOSED TERMINAL | | | LANDSCAPE ISLANDS. IDENTIFY/INDICATE THE REQUESTED | | | VARIANCE RELATING TO THE TERMINAL LANDSCAPE ISLANDS ON | | | THE LANDSCAPE PLAN (SHEET NO. LP-1), IF THIS IS STILL | | | THE CASE AFTER THE REVISIONS. | | | | | | 13. PROVIDE LOCATIONS AND SCREENING FOR ALL SPECIAL | | | UTILITY STRUCTURES AND ABOVE GROUND APPURTENANCES ON | | | THE LANDSCAPE PLAN (SHEET NO. LP-1). | | | | | | 14. PROVIDE THE DELINEATION OF IRRIGATION COVERAGE, | | | SENSORS AND HIGH, MEDIUM AND LOW ZONES OF WATER USAGE. | | | INCLUDE A STATEMENT THAT ALL LANDSCAPE AREAS, EXCLUDING | | | THOSE AREAS WITH NATIVE NONINVASIVE PLANTS, WILL BE | | | PROVIDED WITH PERMANENT AUTOMATIC IRRIGATION, INCLUDING | | | ADJACENT RIGHTS???OF???WAY. | | | |
|
|
| Review Stop |
PARK |
PARKING |
| Rev No |
1 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
|
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
POLICE |
POLICE |
| Rev No |
1 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
|
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
PU |
PUBLIC UTILITIES |
| Rev No |
2 |
Status |
F |
Date |
06-23-2023 |
|
|
Cont ID |
|
| Sent By |
relizond |
Date |
06-23-2023 |
Time |
15:20 |
Rev Time |
0.00 |
| Received By |
relizond |
Date |
06-23-2023 |
Time |
15:20 |
Sent To |
|
|
| Notes |
| 2023-06-23 15:19:39 | -PLEASE PROVIDE CIVIL DRAWINGS MENTIONED IN SITE PLAN | | | SHEET | | | -PROVIDE CCTV OF ALL EXISTING SANITARY SEWER MAIN | | | FRONTING PROJECT LIMITS BEFORE AND AFTER CONSTRUCTION. | | | -PROVIDE SOFTDIG INFORMATION AT PROPOSED POINT OF | | | CONNECTION | | | -REFER TO THE CITY???S STANDARD DETAILS FOR PLACEMENT | | | OF DDCA AND CITY???S POINT OF SERVICE (POS) WHICH | | | REQUIRES A SECOND VALVE AT R/W | | | -SET UP ALL PLAN SHEETS TO PRINT TO SCALE ON 11X17 | | | -SHOW ALL EXISTING WATER SERVICES/METER BOXES/VALVES | | | VAULTS, AND SANITARY SEWER LATERALS WITHIN PROJECT | | | LIMITS. | | | -ALL EXISTING VALVES AND MANHOLES NEED TO BE LEGIBLE | | | -SHOW EXISTING VALVES AND APPURTENANCES AND CORRECT | | | ALIGNMENT OF EXISTING CITY-MAINTAINED UTILITIES | | | -LABEL ALL UTILITIES TO BE MAINTAINED ON-SITE BY OWNER | | | ENTITY AS ???PRIVATE???, AS APPLICABLE | | | -ALL PROPOSED UTILITY EASEMENTS AND PLACEMENT OF | | | DOMESTIC WATER METER/BACKFLOW PREVENTER ASSEMBLY NOT IN | | | COMPLIANCE WITH APPLICABLE CITY???S STANDARD DETAILS | | | WILL REQUIRE WATER DISTRIBUTION???S APPROVAL. PROVIDE 5 | | | FOOT RADIAL CLEARANCE IN ALL DIRECTIONS. | | | -ALL PROPOSED UTILITY EASEMENTS AND PLACEMENT OF | | | CLEANOUT NOT IN COMPLIANCE WITH APPLICABLE CITY???S | | | STANDARD DETAILS WILL REQUIRE SANITARY COLLECTIONS | | | APPROVAL. PROVIDE 5 FOOT RADIAL CLEARANCE IN ALL | | | DIRECTIONS. | | | -PROVIDE PROFILES FOR ALL CONNECTIONS TO EXISTING | | | CITY-MAINTAINED UTILITIES FROM THE POINT OF CONNECTION | | | TO THE POINT OF SERVICE. | | | -ON PROFILE VIEW, SHOW ALL EXISTING AND PROPOSED | | | UTILITIES (CITY-MAINTAINED AND DRY UTILITIES), CALL OUT | | | UTILITY TYPE, DIMENSIONS, PIPE MATERIAL, AND VERTICAL | | | CLEARANCE OD TO OD AT EACH UTILITY CROSSING. | | | -PROVIDE DIMENSIONS BETWEEN PROPOSED UTILITIES TO | | | ENSURE PROPER HORIZONTAL CLEARANCE | | | --SINGLE WATER TAPS SERVING DOMESTIC, FIRE LINE, | | | IRRIGATION, AND FIRE HYDRANT PRESENTS ISSUES FOR FUTURE | | | MAINTENANCE/REPAIRS/REPLACEMENTS ETC. AS SHUTDOWN WILL | | | DISRUPT SERVICE | | | -SHOW ALL UTILITY CROSSINGS WITH HORIZONTAL AND | | | VERTICAL SEPARATION, AS WELL AS SPECIFYING THE UTILITY | | | TYPE, SIZE, AND MATERIAL. | | | -PROVIDE LOS CALCULATIONS, AS WELL AS CHANGE IN DEMAND | | | BETWEEN EXISTING CONDITIONS AND PROPOSED CONDITIONS. | | | -PROVIDE PROJECT FACT SHEET | | | -EXISTING WATER AND SEWER SERVICES CURRENTLY SERVING | | | THE PROPERTY, IF NOT USED, NEED TO BE CUT AND CAP AT | | | MAIN. REMOVAL IS REQUIRED IF LARGER THAN 2??? IN | | | DIAMETER, OR AS REQUIRED BY THE RIGHT-OF-WAY???S | | | GOVERNING AGENCY. | | | -INCLUDE LEGEND, DATUM CONVERSION, AND NORTH ARROW ON | | | PLANS | | | -PROPOSED SEWER LATERALS LARGER THAN 6??? WILL REQUIRE | | | CONNECTION A MANHOLE, WITH A CLEANOUT OF THE SAME SIZE | | | INSTALLED AS THE CITY???S POS. | | | -ADD NOTE TO PLANS SPECIFYING THE LIFT STATION THAT THE | | | PROJECT IS UPSTREAM FROM. | | | -PROVIDE A BLOW-UP DETAIL FOR ALL CONNECTION POINTS TO | | | CITY-MAINTAINED UTILITIES. |
|
|
| Review Stop |
PU |
PUBLIC UTILITIES |
| Rev No |
1 |
Status |
F |
Date |
05-11-2023 |
|
|
Cont ID |
|
| Sent By |
relizond |
Date |
05-11-2023 |
Time |
10:35 |
Rev Time |
0.00 |
| Received By |
relizond |
Date |
05-11-2023 |
Time |
10:33 |
Sent To |
|
|
| Notes |
| 2023-05-11 10:34:50 | -NO WATER/SEWER SHEET PROVIDED TO REVIEW UTILITY | | | SERVICE FED TO THE PROPOSED BUILDINGS. |
|
|
| Review Stop |
PU-CS |
PUBLIC UTILITIES CUSTOMER SRVC |
| Rev No |
2 |
Status |
F |
Date |
06-15-2023 |
|
|
Cont ID |
|
| Sent By |
mhurley |
Date |
06-15-2023 |
Time |
08:21 |
Rev Time |
0.00 |
| Received By |
mhurley |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2023-06-15 08:20:56 | PLEASE PROVIDE WRITTEN RESPONSES TO THE FOLLOWING: | | | -SP-010 DOES NOT SHOW ANY WATER MAIN INFORMATION. NEED | | | TO VERIFY WATER MAIN IS SUFFICIENT FOR WATER SERVICES. | | | -THERE ARE NOTES ON SP-010 REFERRING TO CIVIL PLANS FOR | | | EXACT LOCATIONS OF WATER SERVICE CONNECTIONS, BUT | | | CANNOT FIND SHEET WITH THAT INFORMATION. PLEASE ADD | | | ADDITIONAL SHEET WITHIN CIVIL ENGINEERING PLAN SET | | | SHOWING THAT INFORMATION IN DETAIL. | | | -ADD GRAPHIC SCALE TO SP-010 | | | -IRRIGATION METER IS SHOWN DOWNSTREAM OF DOMESTIC | | | METER. CITY CANNOT PROVIDE METERS IN SERIES. THAT WOULD | | | HAVE TO BE A PRIVATE SUB METER. PLEASE REVISE CALLOUT | | | LABEL TO REFLECT THAT. | | | -CALLOUT DUCTILE IRON PIPE (DIP) UPSTREAM OF DCDA. | | | -FIRELINE WATER SERVICE IS 8 INCH AND WOULD GET BILLED | | | FOR 8 INCH. DCDA SIZE SHOULD MATCH FIRELINE SIZE. NOT | | | SURE IF THE 4 INCH SIZE WAS TYPO. THAT SIZE IS TOO | | | SMALL FOR DOWNSTREAM FIRE HYDRANTS AS WELL (MINIMUM 6 | | | INCH). | | | -VERIFY PRIVATE FIRE SYSTEM WILL NOT HAVE ANY ADDED | | | CHEMICALS OR AUXILIARY WATER SUPPLY SUCH AS A WELL. | | | -CANNOT FIND WATER AND SEWER DEMAND CALCULATIONS ON | | | ENGINEERING WATER PLAN. | | | -PARALLEL/DUAL DOMESTIC BACKFLOW ASSEMBLIES ARE | | | RECOMMENDED AT 4 INCH WATER METER TO MINIMIZE WATER | | | OUTAGES DURING BACKFLOW TESTING AND MAINTENANCE. | | | -DOMESTIC WATER SERVICE, WATER METER, AND BACKFLOW | | | ASSEMBLY NEAR NORTH SIDE OF PROPERTY IS NOT SHOWN ON | | | LANDSCAPING PLAN. PLEASE ADD AND ENSURE NO LOCATION | | | CONFLICTS BETWEEN PLANTS AND UTILITIES. | | | -SURVEY IS NOT SIGNED, SEALED, AND DATED. | | | -SURVEY DID NOT MENTION ANY EASEMENTS. WAS THERE A | | | SEARCH TO VERIFY IF THERE ARE ANY EXISTING EASEMENTS AT | | | THE PROPERTY? NEED TO VERIFY IF THERE ARE ANY EASEMENTS | | | IF HAVE NOT ALREADY AS CAN AFFECT BACKFLOW ASSEMBLY | | | LOCATION. | | | -WATER METER IS SHOWN ON PRIVATE PROPERTY, BUT DO NOT | | | SEE UTILITY EASEMENT. | | | RESPECTFULLY, | | | MARK HURLEY [email protected] |
|
|
| Review Stop |
PU-CS |
PUBLIC UTILITIES CUSTOMER SRVC |
| Rev No |
1 |
Status |
F |
Date |
05-05-2023 |
|
|
Cont ID |
|
| Sent By |
mhurley |
Date |
05-05-2023 |
Time |
13:06 |
Rev Time |
0.00 |
| Received By |
mhurley |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2023-05-05 13:06:39 | PLEASE PROVIDE WRITTEN RESPONSES TO THE FOLLOWING: | | | -ON SITE PLAN S-1, ARE THE BUILDINGS EXISTING OR | | | PROPOSED? | | | -IN RESUBMITTAL PACKAGE, ADD COPIES OF SURVEY AND | | | WATER/SEWER PLANS. WILL PROVIDE MORE REVIEW COMMENTS | | | ONCE ABLE TO REVIEW THOSE. | | | -UTILITY BILLING SYSTEM SHOWS AN EXISTING 1 INCH | | | DOMESTIC WATER METER AT THE PROPERTY. | | | -BELOW IS A LIST OF SOME STANDARD REVIEW COMMENTS THAT | | | MAY ASSIST YOU: | | | *EXISTING AND PROPOSED METERED WATER SERVICES SHOWN AND | | | LABELED. | | | *DOMESTIC BACKFLOW ASSEMBLIES SHOULD BE LOCATED ON | | | PRIVATE PROPERTY OUTSIDE OF ANY UTILITY EASEMENTS AND | | | ADJACENT TO PROPERTY/ROW LINE WITH PIPE DISTANCE | | | MINIMIZED TO METER. | | | *DOMESTIC BACKFLOW ASSEMBLIES LABELED WITH ???RP??? | | | TYPE AND SIZE. | | | *FIRELINE BACKFLOW ASSEMBLY LABELED WITH TYPE (DCDA OR | | | RPDA) AND SIZE. IF DCDA TYPE PROPOSED, NEED | | | VERIFICATION PRIVATE FIRE SYSTEM WILL HAVE NO ADDED | | | CHEMICALS OR AUXILIARY WATER SUPPLIES SUCH AS WELLS. | | | *WATER METERS LABELED WITH SIZE AND USE TYPE | | | (DOMESTIC/IRRIGATION). METERS 3 INCHES OR LARGER | | | LABELED ???ABOVE-GROUND???. | | | *PROPERTY LINES, EASEMENTS, TRANSFORMERS, GREASE TRAPS, | | | RIGHT OF WAYS, GUY ANCHOR WIRES, STREETS, FENCES, | | | WALLS, POLES, FRANCHISE UTILITIES, SIDEWALKS, SIGNS, | | | FDCS, DRIVEWAYS, CLEANOUTS, SANITARY SEWER LATERALS, | | | AND STRUCTURES SHOWN AND LABELED. | | | *FIRE SPRINKLERS MAY NOT RUN OFF DOMESTIC WATER METERS | | | AND NEEDS TO BE ON A SEPARATE WATER SERVICE WITH | | | DETECTOR STYLE BACKFLOW ASSEMBLY. IF NO FIRE SERVICE | | | SHOWN ON PLANS, NEED VERIFICATION NO FIRE SPRINKLERS | | | WILL BE IN BUILDINGS. | | | *PLANS SHOULD HAVE NORTH DIRECTION ARROW, VISUAL SCALE | | | MEASUREMENT ICON / GRAPHIC SCALE, ADDRESS, AND DATE. | | | *DOMESTIC WATER METERS NOT LOCATED IN BUILDINGS OR | | | DRIVEWAYS. PREFERRED LOCATION IN LANDSCAPE (NOT | | | HARDSCAPE) ADJACENT PROPERTY LINE WITH DISTANCE | | | MINIMIZED TO RIGHT OF WAY AND WATER MAIN. | | | *ALL INSTALLED CONTAINMENT BACKFLOW ASSEMBLIES MUST BE | | | LEAD-FREE AND USC-APPROVED (BY SIZE, MAKE, MODEL, | | | ORIENTATION, VALVING, AND BYPASS). | | | *TREES, TREE ROOTS, AND BUSHES NOT ENCROACHING ON WATER | | | METERS AND BACKFLOW ASSEMBLIES. SHOW METERED WATER | | | SERVICES AND BACKFLOW ASSEMBLIES ON | | | LANDSCAPING/PLANTING PLANS. | | | *FIRELINE BACKFLOW ASSEMBLY SHOULD BE INSTALLED ON | | | PRIVATE PROPERTY OUTSIDE OF ANY UTILITY EASEMENTS AT A | | | LOCATION COMPLIANT WITH FIRE CODE AND MINIMIZING PIPE | | | DISTANCE TO WATER MAIN (ADJACENT PROPERTY/ROW LINE | | | WHENEVER POSSIBLE). | | | *POLES AND STRUCTURES MINIMUM 3 FEET AWAY FROM WATER | | | METER BOXES. | | | *DOMESTIC WATER METERS ACCESSIBLE FROM RIGHT OF WAY AND | | | NOT LOCKED BEHIND ANY GATES, FENCES, OR WALLS. | | | *WATER METERS 6 INCH OR LARGER NEED BE ACCESSIBLE AND | | | REPLACEABLE BY FORD F350 CRANE TRUCK. | | | *WATER METERS 8 INCHES AND LARGER ARE NOT STOCKED AND | | | HAVE TO BE ORDERED AFTER UTILITY QUOTE IS PAID. LEAD | | | TIMES MAY BE OVER 6 MONTHS FROM TIME OF PAYMENT. | | | RESPECTFULLY, | | | MARK HURLEY [email protected] | | | |
|
|
| Review Stop |
PW |
PUBLIC WORKS |
| Rev No |
2 |
Status |
F |
Date |
06-22-2023 |
|
|
Cont ID |
|
| Sent By |
jbjoseph |
Date |
06-22-2023 |
Time |
11:05 |
Rev Time |
0.00 |
| Received By |
jbjoseph |
Date |
06-22-2023 |
Time |
11:04 |
Sent To |
|
|
| Notes |
| 2023-06-22 11:05:45 | PREVIOUS COMMENTS HAVE NOT BEEN ADDRESSED. | | | | | | 1. IF THE DUMPSTER IS TO BE ROLLED OUT FOR PICKUP, IT | | | HAS TO BE ROLLED OUT TO A SAFE AND ACCESSIBLE LOCATION | | | ON YOUR PROPERTY. ??PLEASE IDENTIFY LOCATION ON PLANS. | | | | | | 2. PROVIDE LOS (LEVEL OF SERVICE ANALYSIS) TO REFLECT | | | THE SOLID WASTE VOLUME PRODUCED ALONG WITH THE SIZE, | | | TYPE AND QUANTITY OF THE CONTAINER (I.E. | | | DUMPSTER/COMPACTOR) THAT WILL BE UTILIZED FOR THE | | | SANITATION SERVICE. | | | | | | BRUCELY A. JOSEPH | | | PUBLIC WORKS PROGRAM MANAGER | | | [email protected] | | | | | | |
|
|
| Review Stop |
PW |
PUBLIC WORKS |
| Rev No |
1 |
Status |
F |
Date |
05-10-2023 |
|
|
Cont ID |
|
| Sent By |
jbjoseph |
Date |
05-10-2023 |
Time |
16:09 |
Rev Time |
0.00 |
| Received By |
jbjoseph |
Date |
05-10-2023 |
Time |
16:07 |
Sent To |
|
|
| Notes |
| 2023-05-10 16:08:43 | PLEASE PROVIDE THE FOLLOWING: | | | 1. DUMPSTER ENCLOSURE DETAILS FOR SANITATION SERVICE | | | (I.E. SOLID WASTE CONTAINER(S) TYPE, COLLECTION | | | LOCATION, ETC.). FOR A FREESTANDING SITE DUMPSTER | | | ENCLOSURE. THE ENCLOSURE SHALL COMPLY WITH THE LATEST | | | REVISION OF CITY OF WEST PALM BEACH GENERAL | | | CONSTRUCTION GARBAGE ENCLOSURE STANDARD. GC-7 | | | 2. LOS (LEVEL OF SERVICE ANALYSIS) TO REFLECT THE SOLID | | | WASTE VOLUME PRODUCED ALONG WITH THE SIZE, TYPE AND | | | QUANTITY OF THE CONTAINER (I.E. DUMPSTER/COMPACTOR) | | | THAT WILL BE UTILIZED FOR THE SANITATION SERVICE. | | | 3. PROVIDE AN AUTOTURN PLAN.?? TRAVEL PATHS SHOULD | | | BEGIN OUTSIDE THE SITE ILLUSTRATING THE TURN ONTO THE | | | PRIMARY ENTRY ROAD/DRIVE, MANEUVERING AROUND THE SITE, | | | AND COMPLETED WITH AN ILLUSTRATION DEMONSTRATING | | | EXITING THE SITE. PATHS MUST ILLUSTRATE THE FULL | | | VEHICLE SWEPT PATH (INCLUDING WHEEL TRACKS AND | | | OUT-TO-OUT VEHICLE OVERHANG SWEEP) AND MUST INDICATE A | | | CLEAR, UNOBSTRUCTED TRAVEL AROUND THE SITE WITHOUT | | | IMPACT/COLLISIONS TO BUILDINGS, CURBS, LANDSCAPING, | | | PARKING SPACES, VEHICLES, ETC??? | | | | | | AUTOTURN EXHIBIT WITH DYNAMIC ENVELOPE AND THE | | | VEHICLE'S WHEEL PATH IDENTIFIED WITH DIFFERENT COLORS | | | FOR THE SANITATION SERVICE, FRONT LOADER TRUCK WITH THE | | | FOLLOWING SPECS: | | | - DUAL AXLES | | | - TRUCK LENGTH: 35 FT | | | - TIRE PATH WIDTH: 8FT | | | - DYNAMIC ENVELOPE WIDTH: 11 FT | | | - TURNING RADIUS: | | | - SAE TURNING RADIUS: 325FT | | | - CURB TO CURB DIAMETER: 74 FT | | | - WALL TO WAII DIAMETER: 86 3FT | | | | | | BRUCELY A. JOSEPH | | | PUBLIC WORKS PROGRAM MANAGER | | | [email protected] | | | | | | |
|
|
| Review Stop |
STORM |
STORMWATER |
| Rev No |
2 |
Status |
F |
Date |
06-27-2023 |
|
|
Cont ID |
|
| Sent By |
tward |
Date |
06-27-2023 |
Time |
12:21 |
Rev Time |
0.00 |
| Received By |
tward |
Date |
06-27-2023 |
Time |
12:23 |
Sent To |
|
|
| Notes |
| 2023-06-27 12:21:45 | THE FOLLOWING COMMENTS ARE FROM THE REVIEW OF THE | | | 6/2/2023 SUBMITTAL. | | | | | | 1. [SATISFIED] 45TH ST. IS MAINTAINED BY PALM BEACH | | | COUNTY. ANY WORK PROPOSED IN THE R/W WILL NEED TO BE | | | PERMITTED BY PBC. | | | | | | 2. [NOT SATISFIED - PAVING MARKING AND SIGNAGE PLAN | | | REFERS TO BCTED] REMOVE REFERENCES TO BROWARD COUNTY. | | | | | | 3. [SATISFIED] IF SITE IS WITHIN A SPECIAL FLOOD HAZARD | | | AREA THEN THE BUILDINGS AND MECHANICAL EQUIPMENT ARE TO | | | BE LOCATED A MINIMUM OF TWO FEET ABOVE THE BASE FLOOD | | | ELEVATIONS (2 FEET OF FREEBOARD). SITE DOES NOT APPEAR | | | TO BE WITHIN A SFHA. | | | | | | 4. [NOT SATISFIED - RESPONSE INDICATED LETTER WAS | | | FORTHCOMING] PROVIDE LETTER FROM ADJACENT PROPERTY | | | OWNER TO THE SOUTH (SCHOOL BOARD OF PALM BEACH COUNTY) | | | OR OWNER OF ANY DRAINAGE EASEMENT APPROVING THE | | | DRAINAGE CONNECTION AND DISCHARGE ONTO THEIR SITE OR | | | EASEMENT. PROVIDE A COPY OF THE EASEMENT IF APPLICABLE. | | | | | | 5. [SATISFIED] LABEL MH#9 ON SHEET C-1. | | | | | | 6. [NOT SATISFIED - SECTIONS ON SHEET C-2 SHOW THE | | | FOOTER CROSSING THE PROPERTY LINE.] WALL FOOTERS SHOULD | | | BE CONSTRUCTED ENTIRELY WITHIN THE PROPERTY BOUNDARY. | | | | | | 7. [PARTIALLY SATISFIED - CONTOURS REMOVED FROM PGD | | | PLAN BUT SECTIONS ON SHEET C-2 SHOW DEPRESSED AREAS AND | | | THE PGD PLAN SHOWS STORM PIPES EXTENDING INTO THE | | | FORMALLY GRADED AREAS.] EXPLAIN OR SHOW HOW THE | | | RETENTION AREAS WILL DRAIN. RE-LABEL AS DETENTION AREAS | | | IF THERE WILL BE CONNECTIONS TO THE ONSITE DRAINAGE | | | SYSTEM AND OUTFALL PIPE. | | | | | | 8. [SATISFIED] CREATE A SWALE ALONG THE BACK OF | | | SIDEWALK ALONG 45TH STREET TO PREVENT DIRECT RUNOFF | | | ONTO THE SIDEWALK. | | | | | | 9. [SATISFIED] LABEL THE LANDSCAPE BUFFER ON SECTION | | | B-B. | | | | | | 10. [SATISFIED] ADD TO SHEET C-2 THE VERTICAL DATUM | | | CONVERSION EQUATION TO NGVD1929. | | | | | | 11. [SATISFIED - PARKING STALLS DO NOT APPEAR TO BE | | | REDUCED IN LENGTH] CONSIDER REDUCING THE AMOUNT OF | | | IMPERVIOUS AREA BY REDUCING THE PARKING STALL DEPTHS | | | AND PROVIDING TWO FEET OF LANDSCAPED OVERHANG. THE | | | RAISED CURB CAN FUNCTION AS THE WHEEL STOPS. | | | | | | 12.[NOT SATISFIED - THIS INFORMATION WILL BE NEEDED ON | | | THE ENGINEERING PERMIT SET OF DRAWINGS] LABEL TOP AND | | | BOTTOM ELEVATIONS OF THE EXFILTRATION TRENCH AND TRENCH | | | WIDTH ON THE EXFILTRATION TRENCH DETAIL. ADD THE | | | VERTICAL DATUM AND CONVERSION EQUATION TO NGVD1929 TO | | | THE SHEET. | | | | | | 13. [NOT SATISFIED - SHEETS C-1 AND C-4 SHOW THE STOP | | | BAR RIGHT BEHIND THE SIDEWALK ALONG 45TH ST.] MOVE STOP | | | SIGN/STOP BAR 4 FEET FROM BACK OF SIDEWALK. | | | | | | 14. [PARTIALLY SATISFIED - SHOW DRIVEWAY APRON WITHIN | | | THE RIGHT OF WAY AS CONCRETE] PROVIDE A CROSS SECTION | | | OF THE DRIVEWAY. SHOW AND LABEL RIGHT OF WAY (45TH ST), | | | SURFACE BREAKS, DIMENSIONS BETWEEN SURFACE BREAK | | | POINTS, GENERAL SURFACE SLOPES AND MATERIAL, HIGH POINT | | | OF DRIVEWAY AND DISTANCE FROM THE R/W. MINIMIZE THE | | | DISTANCE TO THE DRIVEWAY HIGH POINT BY MAXIMIZING THE | | | DRIVEWAY SLOPE BEHIND THE SIDEWALK. PROVIDE ADA | | | COMPLIANT SIDEWALK ACROSS THE DRIVEWAY APRON. | | | | | | 15. [SATISFIED] PROVIDE PARKING SPACE STRIPING DETAIL | | | AS SHOWN IN SECTION 94-485 OF THE CITY'S CODE OF | | | ORDINANCES. | | | | | | 16. [SATISFIED] NO SURVEY WAS PROVIDED. | | | | | | 17. [SATISFIED] NO WATER AND SEWER PLAN WAS PROVIDED. | | | | | | NEW COMMENTS (6/2/2023 SUBMITTAL): | | | | | | 18. ON EVERY SHEET WITH ELEVATION INFORMATION, PROVIDE | | | THE VERTICAL DATUM REFERENCE AND CONVERSION EQUATION TO | | | NGVD1929. | | | | | | 19. BUILDING OUTLINES ARE NOT SHOWN ON THE CIVIL PLANS. | | | | | | 20. LANDSCAPE PLANS DO NOT SHOW ALL OF THE UTILITIES. | | | | | | | | | TRACY WARD, PE | | | SENIOR STORMWATER ENGINEER | | | ENGINEERING SERVICES DEPARTMENT | | | 561-494-1120 (O) | | | [email protected] | | | |
|
|
| Review Stop |
STORM |
STORMWATER |
| Rev No |
1 |
Status |
F |
Date |
05-10-2023 |
|
|
Cont ID |
|
| Sent By |
tward |
Date |
05-10-2023 |
Time |
17:07 |
Rev Time |
0.00 |
| Received By |
tward |
Date |
05-10-2023 |
Time |
17:08 |
Sent To |
|
|
| Notes |
| 2023-05-10 17:07:34 | THIS IS A CONCEPTUAL LEVEL REVIEW. CONSTRUCTION LEVEL | | | DETAILS, DESIGN CALCULATIONS AND THE POLLUTION | | | PREVENTION PLAN WILL BE REVIEWED AS PART OF THE | | | ENGINEERING DEVELOPMENT APPROVAL AND BUILDING PERMIT | | | APPLICATION PROCESSES. | | | | | | THE FOLLOWING COMMENTS MUST BE ADDRESSED PRIOR TO SITE | | | PLAN APPROVAL: | | | | | | 1. 45TH ST. IS MAINTAINED BY PALM BEACH COUNTY. ANY | | | WORK PROPOSED IN THE R/W WILL NEED TO BE PERMITTED BY | | | PBC. | | | | | | 2. REMOVE REFERENCES TO BROWARD COUNTY. | | | | | | 3. IF SITE IS WITHIN A SPECIAL FLOOD HAZARD AREA THEN | | | THE BUILDINGS AND MECHANICAL EQUIPMENT ARE TO BE | | | LOCATED A MINIMUM OF TWO FEET ABOVE THE BASE FLOOD | | | ELEVATIONS (2 FEET OF FREEBOARD). SITE DOES NOT APPEAR | | | TO BE WITHIN A SFHA. | | | | | | 4. PROVIDE LETTER FROM ADJACENT PROPERTY OWNER TO THE | | | SOUTH (SCHOOL BOARD OF PALM BEACH COUNTY) OR OWNER OF | | | ANY DRAINAGE EASEMENT APPROVING THE DRAINAGE CONNECTION | | | AND DISCHARGE ONTO THEIR SITE OR EASEMENT. PROVIDE A | | | COPY OF THE EASEMENT IF APPLICABLE. | | | | | | 5. LABEL MH#9 ON SHEET C-1. | | | | | | 6. WALL FOOTERS SHOULD BE CONSTRUCTED ENTIRELY WITHIN | | | THE PROPERTY BOUNDARY. | | | | | | 7. EXPLAIN OR SHOW HOW THE RETENTION AREAS WILL DRAIN. | | | RE-LABEL AS DETENTION AREAS IF THERE WILL BE | | | CONNECTIONS TO THE ONSITE DRAINAGE SYSTEM AND OUTFALL | | | PIPE. | | | | | | 8. CREATE A SWALE ALONG THE BACK OF SIDEWALK ALONG 45TH | | | STREET TO PREVENT DIRECT RUNOFF ONTO THE SIDEWALK. | | | | | | 9. LABEL THE LANDSCAPE BUFFER ON SECTION B-B. | | | | | | 10. ADD TO SHEET C-2 THE VERTICAL DATUM CONVERSION | | | EQUATION TO NGVD1929. | | | | | | 11. CONSIDER REDUCING THE AMOUNT OF IMPERVIOUS AREA BY | | | REDUCING THE PARKING STALL DEPTHS AND PROVIDING TWO | | | FEET OF LANDSCAPED OVERHANG. THE RAISED CURB CAN | | | FUNCTION AS THE WHEEL STOPS. | | | | | | 12. LABEL TOP AND BOTTOM ELEVATIONS OF THE EXFILTRATION | | | TRENCH AND TRENCH WIDTH ON THE EXFILTRATION TRENCH | | | DETAIL. ADD THE VERTICAL DATUM AND CONVERSION EQUATION | | | TO NGVD1929 TO THE SHEET. | | | | | | 13. MOVE STOP SIGN/STOP BAR 4 FEET FROM BACK OF | | | SIDEWALK. | | | | | | 14. PROVIDE A CROSS SECTION OF THE DRIVEWAY. SHOW AND | | | LABEL RIGHT OF WAY (45TH ST), SURFACE BREAKS, | | | DIMENSIONS BETWEEN SURFACE BREAK POINTS, GENERAL | | | SURFACE SLOPES AND MATERIAL, HIGH POINT OF DRIVEWAY AND | | | DISTANCE FROM THE R/W. MINIMIZE THE DISTANCE TO THE | | | DRIVEWAY HIGH POINT BY MAXIMIZING THE DRIVEWAY SLOPE | | | BEHIND THE SIDEWALK. PROVIDE ADA COMPLIANT SIDEWALK | | | ACROSS THE DRIVEWAY APRON. | | | | | | 15. PROVIDE PARKING SPACE STRIPING DETAIL AS SHOWN IN | | | SECTION 94-485 OF THE CITY'S CODE OF ORDINANCES. | | | | | | 16. NO SURVEY WAS PROVIDED. | | | | | | 17. NO WATER AND SEWER PLAN WAS PROVIDED. | | | | | | THE FOLLOWING COMMENTS MUST BE ADDRESSED PRIOR TO | | | ISSUANCE OF CONSTRUCTION AUTHORIZATION INCLUDING | | | BUILDING PERMITS AND ENGINEERING DEVELOPMENT APPROVAL. | | | | | | 1. DRAINAGE SYSTEM TO BE DESIGNED TO MEET SFWMD ERP | | | CRITERIA. STORMWATER CALCULATIONS WILL BE REVIEWED WITH | | | THE ENGINEERING PERMIT SUBMITTAL. | | | | | | 2. PROVIDE COPY OF SFWMD ERP PERMIT BEFORE START OF | | | CONSTRUCTION. | | | | | | 3. PROVIDE EROSION AND SEDIMENT CONTROL PLAN WITH THE | | | ENGINEERING PERMIT SUBMITTAL. | | | | | | | | | | | | TRACY WARD, PE | | | SENIOR STORMWATER ENGINEER | | | ENGINEERING SERVICES DEPARTMENT | | | 561-494-1120 (O) | | | [email protected] | | | |
|
|
| Review Stop |
SURVEY |
SURVEYING |
| Rev No |
2 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2023-06-30 10:49:16 | 1. ENG. AND ARCH. PLANS HAVE 2 DIFFERENT SURVEYS. | | | SURVEY NEEDS TO BE SIGNED AND SEALED. | | | 2. ADD CONVERSION TO NGVD-29 ON SURVEY. | | | 3. PIPING PLAN(PART OF ENG. PLANS) REFERS TO ENG. PLANS | | | FOR LOCATION OF UTILITIES IN 45TH STREET. NO CITY OR | | | OTHER UTILITIES SHOWN FOR 45TH STREET. | | | 4. NEED INFORMATION FOR CANAL TO THE SOUTH FOR YOUR | | | ABILITY TO UTILIZE. | | | 5. UNITY OF TITLE WILL BE REQUIRED. APPLICATION IS MADE | | | THROUGH THIS OFFICE. |
|
|
| Review Stop |
SURVEY |
SURVEYING |
| Rev No |
1 |
Status |
F |
Date |
05-10-2023 |
|
|
Cont ID |
|
| Sent By |
vnoel |
Date |
05-10-2023 |
Time |
13:33 |
Rev Time |
|
| Received By |
vnoel |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
TRAFFIC |
TRAFFIC ENGINEERING |
| Rev No |
2 |
Status |
F |
Date |
06-21-2023 |
|
|
Cont ID |
|
| Sent By |
|
Date |
06-21-2023 |
Time |
|
Rev Time |
0.00 |
| Received By |
|
Date |
06-21-2023 |
Time |
|
Sent To |
|
|
| Notes |
| 2023-06-21 23:37:36 | TRAFFIC COMMENTS | | | 1) SATISFIED. THE TRAFFIC STUDY IS MISSING TABLES AND | | | FIGURES. PLEASE REVISE | | | 2) PARTIALLY SATISFIED. PROVIDE COUNTY TPS LETTER, ONCE | | | RECEIVED | | | 3) NOT SATISFIED. DUE TO THE PARKING VARIANCE REQUEST, | | | PROPER TRANSPORTATION DEMAND MANAGEMENT MEASURES MUST | | | BE CONTEMPLATED AND IMPLEMENTED. PLEASE PROVIDE A DRAFT | | | DOCUMENT WITH PROPOSED TDM MEASURES; AND SETUP A | | | FOLLOW-UP MEETING FOR REVIEW, DISCUSSION AND | | | FINALIZATION PURPOSES | | | | | | SITE COMMENTS | | | 4) NOT SATISFIED. PROVIDE A TRANSPORTATION SPECIFIC | | | SITE PLAN FOR THE GROUND FLOOR. SHOWCASING | | | TRANSPORTATION RELATED FEATURES (E.G. ROADWAY WIDTHS, | | | DRIVING AISLES, PARKING STALLS, SIDEWALK, CURB, GUTTER, | | | DRIVEWAY, GATES, CROSSWALKS, VISIBILITY TRIANGLE, | | | CORNER & DRIVEWAY SEPARATION DISTANCES, SLOPES, ETC.) | | | PROPERLY LABELED AND DIMENSIONED. THE SITE PLAN SHOULD | | | BE NAMED T-1.0. PLEASE PROVIDE DOCUMENT NAME AND/OR | | | SHEET NUMBER | | | 5) NOT SATISFIED. PROVIDE A SIGNING & PAVEMENT MARKING | | | PLAN. INCLUSIVE OF ALL FEATURES WITHIN THE PROPOSED | | | DEVELOPMENT AND ALONG ALL ROADS FRONTING THE SITE. SUCH | | | PLAN CAN BE INTEGRATED IN THE TRANSPORTATION SITE PLAN. | | | PLEASE PROVIDE DOCUMENT NAME AND/OR SHEET NUMBER | | | 6) NOT SATISFIED. PROVIDE AUTOTURN ANALYSIS FOR GARBAGE | | | TRUCK AND/OR SERVICE VEHICLES DRIVING IN AND OUT OF THE | | | PROPOSED DEVELOPMENT WITH VEHICLE DYNAMIC ENVELOPES AND | | | WHEEL PATHS CLEARLY DISTINCT AND DEFINED IN DIFFERENT | | | COLORS | | | 7) SATISFIED. PROVIDE A DEDICATED TURNAROUND SPACE AT | | | EACH PARKING LOT DEAD-END | | | 8) SATISFIED. ARE THERE ANY BUS STOPS BEING IMPACTED? | | | 9) SATISFIED. IS THE PROPOSED DEVELOPMENT IMPACTING AN | | | EXISTING BICYCLE FACILITY? | | | 10) NOT SATISFIED. PROVIDE A CONSTRUCTION MANAGEMENT | | | PLAN. PLEASE REFER TO CITY CODE 86-246 FOR DETAILS. | | | 11) PROVIDE A PARKING TABLE SHOWCASING THE NUMBER OF | | | REQUIRED AND PROVIDED PARKING STALLS. PLEASE PROVIDE | | | DOCUMENT NAME OR SHEET NUMBER SHOWCASING SUCH | | | INFORMATION | | | 12) A DEDICATED TURN-AROUND SPACE MUST BE PROVIDED AT | | | EACH PARKING LOT DEAD-END; SUCH SPACE MUST BE CLEARLY | | | MARKED AND SIGNED | | | | | | VALERIO ORICCHIO | | | CITY TRANSPORTATION ENGINEER | | | 561-494-1092 | | | [email protected] | | | |
|
|
| Review Stop |
TRAFFIC |
TRAFFIC ENGINEERING |
| Rev No |
1 |
Status |
F |
Date |
05-11-2023 |
|
|
Cont ID |
|
| Sent By |
|
Date |
05-11-2023 |
Time |
|
Rev Time |
|
| Received By |
|
Date |
05-11-2023 |
Time |
|
Sent To |
|
|
| Notes |
| 2023-05-11 01:47:13 | TRAFFIC COMMENTS | | | 1) THE TRAFFIC STUDY IS MISSING TABLES AND FIGURES. | | | PLEASE REVISE | | | 2) PROVIDE COUNTY TPS LETTER | | | 3) DUE TO THE PARKING VARIANCE REQUEST, PROPER | | | TRANSPORTATION DEMAND MANAGEMENT MEASURES MUST BE | | | CONTEMPLATED AND IMPLEMENTED | | | | | | SITE COMMENTS | | | 4) PROVIDE A TRANSPORTATION SPECIFIC SITE PLAN FOR THE | | | GROUND FLOOR. SHOWCASING TRANSPORTATION RELATED | | | FEATURES (E.G. ROADWAY WIDTHS, DRIVING AISLES, PARKING | | | STALLS, SIDEWALK, CURB, GUTTER, DRIVEWAY, GATES, | | | CROSSWALKS, VISIBILITY TRIANGLE, CORNER & DRIVEWAY | | | SEPARATION DISTANCES, SLOPES, ETC.) PROPERLY LABELED | | | AND DIMENSIONED. THE SITE PLAN SHOULD BE NAMED T-1.0 | | | 5) PROVIDE A SIGNING & PAVEMENT MARKING PLAN. INCLUSIVE | | | OF ALL FEATURES WITHIN THE PROPOSED DEVELOPMENT AND | | | ALONG ALL ROADS FRONTING THE SITE. SUCH PLAN CAN BE | | | INTEGRATED IN THE TRANSPORTATION SITE PLAN | | | 6) PROVIDE AUTOTURN ANALYSIS FOR GARBAGE TRUCK AND/OR | | | SERVICE VEHICLES DRIVING IN AND OUT OF THE PROPOSED | | | DEVELOPMENT WITH VEHICLE DYNAMIC ENVELOPES AND WHEEL | | | PATHS CLEARLY DISTINCT AND DEFINED IN DIFFERENT COLORS | | | 7) PROVIDE A DEDICATED TURNAROUND SPACE AT EACH PARKING | | | LOT DEAD-END | | | 8) ARE THERE ANY BUS STOPS BEING IMPACTED? | | | 9) IS THE PROPOSED DEVELOPMENT IMPACTING AN EXISTING | | | BICYCLE FACILITY? | | | 10) PROVIDE A CONSTRUCTION MANAGEMENT PLAN. PLEASE | | | REFER TO CITY CODE 86-246 FOR DETAILS. | | | | | | VALERIO ORICCHIO | | | CITY TRANSPORTATION ENGINEER | | | 561-494-1092 | | | [email protected] | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
06-20-2023 |
|
|
Cont ID |
|
| Sent By |
kdefranc |
Date |
06-20-2023 |
Time |
17:00 |
Rev Time |
0.00 |
| Received By |
kdefranc |
Date |
06-20-2023 |
Time |
16:59 |
Sent To |
|
|
| Notes |
| 2023-06-20 16:59:54 | 6/20/23 - FAILED | | | | | | | | | PLEASE NOTE THE FOLLOWING PROCESS COMMENTS WHEN | | | RESUBMITTING: | | | A. WRITTEN RESPONSES TO COMMENTS MADE BY ALL | | | DEPARTMENTS SHALL BE PROVIDED UPON RESUBMISSION. | | | B. PROVIDE AN ELECTRONIC COPY OF ALL PLANS AND REQUIRED | | | MATERIALS AND 2 SETS OF FOLDED PHYSICAL PLANS, ALONG | | | WITH ONE (1) REDUCED COPY (11 IN X 17 IN). | | | C. PLEASE NOTE THAT RE-SUBMITTALS MAY BE SUBJECT TO | | | ADDITIONAL COMMENTS. | | | D. IF NO RESPONSE IS RECEIVED WITHIN 60 DAYS OF THE | | | ISSUANCE OF THESE COMMENTS, THE APPLICATION WILL BE | | | CONSIDERED WITHDRAWN AND ANY FURTHER ACTION WILL | | | REQUIRE SUBMISSION OF A NEW DEVELOPMENT APPLICATION. | | | E. PLEASE NOTE THAT YOU ARE PERMITTED ONE (1) | | | RESUBMITTAL AT NO ADDITIONAL COST. A RESUBMITTAL FEE OF | | | 20% OF THE ORIGINAL APPLICATION FEE WILL BE ASSESSED | | | AFTER THE FIRST RESUBMITTAL. | | | | | | REQUIRED MATERIALS MUST BE PROVIDED: | | | F. PLEASE PROVIDE A COPY OF THE LAST RECORDED WARRANTY | | | DEED FOR THE SUBJECT PROPERTY. THE PROPERTY OWNER | | | INFORMATION PROVIDED ON THE APPLICATION AND THE | | | OWNER???S CONSENT FORM DO NOT MATCH THE PROPERTY OWNER | | | INFORMATION IN THE WARRANTY DEED SUBMITTED. [NOT | | | SATISFIED] | | | G. PLEASE PROVIDE AN ELECTRONIC COPY OF THE SURVEY. | | | [SATISFIED] | | | H. PLEASE PROVIDE AN ENGINEERING | | | (WATER/WASTEWATER-SPECIFIC) PLAN. [SATISFIED] | | | I. PLEASE PROVIDE PHYSICAL HARDCOPIES OF THE LANDSCAPE | | | PLANS. [SATISFIED] | | | J. PLEASE PROVIDE A TRAFFIC CONCURRENCY/PERFORMANCE | | | STANDARD REVIEW (TPS) LETTER FROM THE PALM BEACH COUNTY | | | TRAFFIC DIVISION FOR THE SUBJECT PROJECT. [NOT | | | SATISFIED] | | | K. PLEASE PROVIDE A SCHOOL CAPACITY AVAILABILITY | | | DETERMINATION (SCAD) PROVIDED BY THE SCHOOL DISTRICT OF | | | PALM BEACH COUNTY FOR THE SUBJECT PROJECT. [NOT | | | SATISFIED] | | | L. PLEASE PROVIDE THE CITY SERVICE AND PUBLIC UTILITY | | | LETTERS (FROM FLORIDA PUBLIC UTILITIES, FLORIDA POWER & | | | LIGHT COMPANY, AND COMCAST CABLE COMMUNICATION) FOR THE | | | SUBJECT PROJECT. [NOT SATISFIED] | | | M. IF A REZONING OF THE SUBJECT PROPERTY IS BEING | | | REQUESTED, THEN A SEPARATE REZONING TYPE OF APPLICATION | | | MUST BE SUBMITTED. [NOT SATISFIED] | | | N. PLEASE PROVIDE REVISED PLANS ADDRESSING THE REVIEW | | | COMMENTS BELOW. [PARTIALLY SATISFIED] | | | O. PLEASE PROVIDE/INDICATE/DEMONSTRATE CONSISTENT | | | INFORMATION ON ALL THE DIFFERENT PLANS AND REQUIRED | | | MATERIALS WITHIN THE APPLICATION PACKET RESUBMITTAL. | | | [NOT SATISFIED] | | | | | | PLANS REVIEW COMMENTS MUST BE ADDRESSED: | | | 1. IN REFERENCE TO REVIEW COMMENT M., THE PLANS | | | SUBMITTED INDICATE A PROPOSED REZONING OF THE SUBJECT | | | PROPERTY. THEREFORE, PLEASE CONFIRM IF A REZONING IS | | | BEING REQUESTED. IF SO, A SEPARATE REZONING TYPE OF | | | APPLICATION MUST BE SUBMITTED. IF NOT, PLEASE CORRECT | | | THE INFORMATION INDICATED IN THE PLANS ACCORDINGLY. | | | [NOT SATISFIED] | | | 2. IN ACCORDANCE WITH RESOLUTION NO. 306-22, THE MF32 | | | ZONING DISTRICT BUILDING HEIGHT REGULATIONS APPLY TO | | | THE PROPOSED PROJECT. BASED ON THE CITY???S ZONING AND | | | LAND DEVELOPMENT REGULATIONS (ZLDR) SECTION | | | 94-77(A)(3), THE PROPOSED PROJECT IS IN COMPLIANCE WITH | | | THE MAXIMUM BUILDING HEIGHT ALLOWANCE OF THE MF32 | | | ZONING DISTRICT. THEREFORE, PLEASE SUBMIT A REVISED | | | JUSTIFICATION LETTER BECAUSE THE REQUESTED VARIANCE TO | | | THE MAXIMUM BUILDING HEIGHT ALLOWANCE IS NOT NECESSARY. | | | [SATISFIED] | | | 3. PLEASE IDENTIFY/INDICATE THE EXISTING/PROPOSED | | | EASEMENTS ON THE PLANS. [NOT SATISFIED] | | | 4. PLEASE IDENTIFY/INDICATE/DEMONSTRATE THE LOCATION OF | | | THE PROPOSED PUBLIC ART ON THE PLANS. [WITHDRAWN] | | | 5. PLEASE IDENTIFY/INDICATE/DEMONSTRATE THE LOCATION OF | | | THE EXISTING AND PROPOSED FIRE HYDRANTS WITHIN 250 FEET | | | OF THE PROPOSED STRUCTURES ON THE PLANS. [SATISFIED] | | | 6. PLEASE IDENTIFY/INDICATE/DEMONSTRATE THE LOCATION OF | | | THE PROPOSED SPECIAL UTILITY STRUCTURES / ABOVE GROUND | | | APPURTENANCES ON THE PLANS. [PARTIALLY SATISFIED] | | | 7. PLEASE IDENTIFY/INDICATE/DEMONSTRATE THE LOCATION, | | | HEIGHT, AND INTENSITY OF THE PROPOSED OUTDOOR | | | ILLUMINATION ON THE PLANS. [PARTIALLY SATISFIED] | | | 8. IN ACCORDANCE WITH THE ZLDR SECTION 94-485(Q), | | | PLEASE IDENTIFY/INDICATE/DEMONSTRATE THE LOCATION OF | | | THE PROPOSED BICYCLE PARKING FACILITIES ON THE PLANS. | | | IDENTIFY/INDICATE THE PROPOSED NUMBER OF BICYCLE | | | PARKING IN THE PARKING TABULATION. [PARTIALLY | | | SATISFIED] | | | 9. IN REGARDS TO THE PROVIDED JUSTIFICATION LETTER FOR | | | THE PARKING REQUIREMENTS, THE SUBJECT PROPERTY IS NOT | | | LOCATED WITHIN THE CITY CENTER DISTRICT. THE CITYWIDE | | | DISTRICT SPECIFIC MINIMUM PARKING REQUIREMENTS APPLY TO | | | THE PROPOSED PROJECT. THEREFORE, PLEASE REVISE THE | | | SUBJECT JUSTIFICATION LETTER. [NOT SATISFIED] | | | 10. PLEASE IDENTIFY/INDICATE/DEMONSTRATE THE LOCATION | | | OF THE DRIVEWAYS, CURB CUTS, AND TURNING LANES ADJACENT | | | TO OR ACROSS FROM THE SUBJECT PROPERTY ON THE PLANS. | | | [NOT SATISFIED] | | | 11. PLEASE PROVIDE THE STANDARD CITY DETAILS/ELEVATIONS | | | OF THE PROPOSED BICYCLE PARKING ON THE PLANS. [NOT | | | SATISFIED] | | | 12. PLEASE IDENTIFY/INDICATE/DEMONSTRATE THE LOCATION | | | OF EXISTING AND PROPOSED PUBLIC TRANSIT FACILITIES | | | WITHIN THE IMMEDIATE VICINITY OF THE SUBJECT PROPERTY | | | ON THE PLANS. [NOT SATISFIED] | | | 13. IN ACCORDANCE WITH RESOLUTION NO. 306-22, PLEASE | | | IDENTIFY/INDICATE THE PROPOSED NUMBER OF AFFORDABLE | | | DESIGNATED DWELLING UNITS IN THE SITE CALCULATIONS. | | | [NOT SATISFIED] | | | 14. IN ACCORDANCE WITH RESOLUTION NO. 306-22, PLEASE | | | PROVIDE THE DENSITY CALCULATIONS IN THE SITE | | | CALCULATIONS. [NOT SATISFIED] | | | 15. IN ACCORDANCE WITH RESOLUTION NO. 306-22, PLEASE | | | CONFIRM THE RESTRICTED UNIT???S AFFORDABILITY PERIOD. | | | [SATISFIED] | | | 16. PLEASE PROVIDE CONSISTENT INFORMATION ON THE SITE | | | PLAN (SHEET NO. SP-1) AND ARCHITECTURAL SITE PLAN | | | (SHEET NO. A100.00) FOR RESUBMITTAL OR DO NOT PROVIDE | | | AN ARCHITECTURAL SITE PLAN AS PART OF THE RESUBMITTAL. | | | [NOT SATISFIED] | | | | | | ADDITIONAL REVIEW COMMENTS MUST BE ADDRESSED: | | | 17. IN REFERENCE TO PREVIOUS REVIEW COMMENT 6., PLEASE | | | IDENTIFY/INDICATE/DEMONSTRATE CONSISTENT INFORMATION | | | REGARDING THE LOCATION OF THE PROPOSED SPECIAL UTILITY | | | STRUCTURES / ABOVE GROUND APPURTENANCES ON THE SITE | | | PLANS, LANDSCAPE PLANS, AND UTILITIES PLANS. | | | 18. IN REFERENCE TO PREVIOUS REVIEW COMMENT 7., PLEASE | | | IDENTIFY/INDICATE/DEMONSTRATE CONSISTENT INFORMATION | | | REGARDING THE LOCATION, HEIGHT, AND INTENSITY OF THE | | | PROPOSED OUTDOOR ILLUMINATION ON THE SITE PLANS, | | | LANDSCAPE PLANS, AND UTILITIES PLANS. | | | 19. IN REFERENCE TO PREVIOUS REVIEW COMMENT 8., PLEASE | | | IDENTIFY/INDICATE/DEMONSTRATE CONSISTENT INFORMATION | | | REGARDING THE LOCATION OF THE PROPOSED BICYCLE PARKING | | | FACILITIES ON THE SITE PLANS AND LANDSCAPE PLANS. | | | PLEASE CORRECT THE REQUIRED NUMBER OF BICYCLE PARKING | | | INFORMATION IN THE PARKING TABULATION. | | | | | | | | | KEVIE DEFRANC | | | SENIOR PLANNER - PLANNING DIVISION | | | [email protected] | | | 561-822-1449 | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
05-05-2023 |
|
|
Cont ID |
|
| Sent By |
kdefranc |
Date |
05-05-2023 |
Time |
11:02 |
Rev Time |
0.00 |
| Received By |
kdefranc |
Date |
05-05-2023 |
Time |
11:01 |
Sent To |
|
|
| Notes |
| 2023-05-05 11:02:02 | 5/5/23 ??? FAILED | | | | | | | | | PLEASE NOTE THE FOLLOWING PROCESS COMMENTS WHEN | | | RESUBMITTING: | | | A. WRITTEN RESPONSES TO COMMENTS MADE BY ALL | | | DEPARTMENTS SHALL BE PROVIDED UPON RESUBMISSION. | | | B. PROVIDE AN ELECTRONIC COPY OF ALL PLANS AND REQUIRED | | | MATERIALS AND 2 SETS OF FOLDED PHYSICAL PLANS, ALONG | | | WITH ONE (1) REDUCED COPY (11 IN X 17 IN). | | | C. PLEASE NOTE THAT RE-SUBMITTALS MAY BE SUBJECT TO | | | ADDITIONAL COMMENTS. | | | D. IF NO RESPONSE IS RECEIVED WITHIN 60 DAYS OF THE | | | ISSUANCE OF THESE COMMENTS, THE APPLICATION WILL BE | | | CONSIDERED WITHDRAWN AND ANY FURTHER ACTION WILL | | | REQUIRE SUBMISSION OF A NEW DEVELOPMENT APPLICATION. | | | E. PLEASE NOTE THAT YOU ARE PERMITTED ONE (1) | | | RESUBMITTAL AT NO ADDITIONAL COST. A RESUBMITTAL FEE OF | | | 20% OF THE ORIGINAL APPLICATION FEE WILL BE ASSESSED | | | AFTER THE FIRST RESUBMITTAL. | | | | | | REQUIRED MATERIALS MUST BE PROVIDED: | | | F. PLEASE PROVIDE A COPY OF THE LAST RECORDED WARRANTY | | | DEED FOR THE SUBJECT PROPERTY. THE PROPERTY OWNER | | | INFORMATION PROVIDED ON THE APPLICATION AND THE | | | OWNER???S CONSENT FORM DO NOT MATCH THE PROPERTY OWNER | | | INFORMATION IN THE WARRANTY DEED SUBMITTED. | | | G. PLEASE PROVIDE AN ELECTRONIC COPY OF THE SURVEY. | | | H. PLEASE PROVIDE AN ENGINEERING | | | (WATER/WASTEWATER-SPECIFIC) PLAN. | | | I. PLEASE PROVIDE PHYSICAL HARDCOPIES OF THE LANDSCAPE | | | PLANS. | | | J. PLEASE PROVIDE A TRAFFIC CONCURRENCY/PERFORMANCE | | | STANDARD REVIEW (TPS) LETTER FROM THE PALM BEACH COUNTY | | | TRAFFIC DIVISION FOR THE SUBJECT PROJECT. | | | K. PLEASE PROVIDE A SCHOOL CAPACITY AVAILABILITY | | | DETERMINATION (SCAD) PROVIDED BY THE SCHOOL DISTRICT OF | | | PALM BEACH COUNTY FOR THE SUBJECT PROJECT. | | | L. PLEASE PROVIDE THE CITY SERVICE AND PUBLIC UTILITY | | | LETTERS (FROM FLORIDA PUBLIC UTILITIES, FLORIDA POWER & | | | LIGHT COMPANY, AND COMCAST CABLE COMMUNICATION) FOR THE | | | SUBJECT PROJECT. | | | M. IF A REZONING OF THE SUBJECT PROPERTY IS BEING | | | REQUESTED, THEN A SEPARATE REZONING TYPE OF APPLICATION | | | MUST BE SUBMITTED. | | | N. PLEASE PROVIDE REVISED PLANS ADDRESSING THE REVIEW | | | COMMENTS BELOW. | | | O. PLEASE PROVIDE/INDICATE/DEMONSTRATE CONSISTENT | | | INFORMATION ON ALL THE DIFFERENT PLANS AND REQUIRED | | | MATERIALS WITHIN THE APPLICATION PACKET RESUBMITTAL. | | | | | | PLANS REVIEW COMMENTS MUST BE ADDRESSED: | | | 1. IN REFERENCE TO REVIEW COMMENT M., THE PLANS | | | SUBMITTED INDICATE A PROPOSED REZONING OF THE SUBJECT | | | PROPERTY. THEREFORE, PLEASE CONFIRM IF A REZONING IS | | | BEING REQUESTED. IF SO, A SEPARATE REZONING TYPE OF | | | APPLICATION MUST BE SUBMITTED. IF NOT, PLEASE CORRECT | | | THE INFORMATION INDICATED IN THE PLANS ACCORDINGLY. | | | 2. IN ACCORDANCE WITH RESOLUTION NO. 306-22, THE MF32 | | | ZONING DISTRICT BUILDING HEIGHT REGULATIONS APPLY TO | | | THE PROPOSED PROJECT. BASED ON THE CITY???S ZONING AND | | | LAND DEVELOPMENT REGULATIONS (ZLDR) SECTION | | | 94-77(A)(3), THE PROPOSED PROJECT IS IN COMPLIANCE WITH | | | THE MAXIMUM BUILDING HEIGHT ALLOWANCE OF THE MF32 | | | ZONING DISTRICT. THEREFORE, PLEASE SUBMIT A REVISED | | | JUSTIFICATION LETTER BECAUSE THE REQUESTED VARIANCE TO | | | THE MAXIMUM BUILDING HEIGHT ALLOWANCE IS NOT NECESSARY. | | | 3. PLEASE IDENTIFY/INDICATE THE EXISTING/PROPOSED | | | EASEMENTS ON THE PLANS. | | | 4. PLEASE IDENTIFY/INDICATE/DEMONSTRATE THE LOCATION OF | | | THE PROPOSED PUBLIC ART ON THE PLANS. | | | 5. PLEASE IDENTIFY/INDICATE/DEMONSTRATE THE LOCATION OF | | | THE EXISTING AND PROPOSED FIRE HYDRANTS WITHIN 250 FEET | | | OF THE PROPOSED STRUCTURES ON THE PLANS. | | | 6. PLEASE IDENTIFY/INDICATE/DEMONSTRATE THE LOCATION OF | | | THE PROPOSED SPECIAL UTILITY STRUCTURES / ABOVE GROUND | | | APPURTENANCES ON THE PLANS. | | | 7. PLEASE IDENTIFY/INDICATE/DEMONSTRATE THE LOCATION, | | | HEIGHT, AND INTENSITY OF THE PROPOSED OUTDOOR | | | ILLUMINATION ON THE PLANS. | | | 8. IN ACCORDANCE WITH THE ZLDR SECTION 94-485(Q), | | | PLEASE IDENTIFY/INDICATE/DEMONSTRATE THE LOCATION OF | | | THE PROPOSED BICYCLE PARKING FACILITIES ON THE PLANS. | | | IDENTIFY/INDICATE THE PROPOSED NUMBER OF BICYCLE | | | PARKING IN THE PARKING TABULATION. | | | 9. IN REGARDS TO THE PROVIDED JUSTIFICATION LETTER FOR | | | THE PARKING REQUIREMENTS, THE SUBJECT PROPERTY IS NOT | | | LOCATED WITHIN THE CITY CENTER DISTRICT. THE CITYWIDE | | | DISTRICT SPECIFIC MINIMUM PARKING REQUIREMENTS APPLY TO | | | THE PROPOSED PROJECT. THEREFORE, PLEASE REVISE THE | | | SUBJECT JUSTIFICATION LETTER. | | | 10. PLEASE IDENTIFY/INDICATE/DEMONSTRATE THE LOCATION | | | OF THE DRIVEWAYS, CURB CUTS, AND TURNING LANES ADJACENT | | | TO OR ACROSS FROM THE SUBJECT PROPERTY ON THE PLANS. | | | 11. PLEASE PROVIDE THE STANDARD CITY DETAILS/ELEVATIONS | | | OF THE PROPOSED BICYCLE PARKING ON THE PLANS. | | | 12. PLEASE IDENTIFY/INDICATE/DEMONSTRATE THE LOCATION | | | OF EXISTING AND PROPOSED PUBLIC TRANSIT FACILITIES | | | WITHIN THE IMMEDIATE VICINITY OF THE SUBJECT PROPERTY | | | ON THE PLANS. | | | 13. IN ACCORDANCE WITH RESOLUTION NO. 306-22, PLEASE | | | IDENTIFY/INDICATE THE PROPOSED NUMBER OF AFFORDABLE | | | DESIGNATED DWELLING UNITS IN THE SITE CALCULATIONS. | | | 14. IN ACCORDANCE WITH RESOLUTION NO. 306-22, PLEASE | | | PROVIDE THE DENSITY CALCULATIONS IN THE SITE | | | CALCULATIONS. | | | 15. IN ACCORDANCE WITH RESOLUTION NO. 306-22, PLEASE | | | CONFIRM THE RESTRICTED UNIT???S AFFORDABILITY PERIOD. | | | 16. PLEASE PROVIDE CONSISTENT INFORMATION ON THE SITE | | | PLAN (SHEET NO. SP-1) AND ARCHITECTURAL SITE PLAN | | | (SHEET NO. A100.00) FOR RESUBMITTAL OR DO NOT PROVIDE | | | AN ARCHITECTURAL SITE PLAN AS PART OF THE RESUBMITTAL. | | | | | | | | | KEVIE DEFRANC | | | SENIOR PLANNER - PLANNING DIVISION | | | [email protected] | | | 561-822-1449 | | | | | | |
|
|
| |