Plan Review Details - Project Z22090021
| Plan Review Stops For Project Z22090021 |
| Review Stop |
AIPP |
ART IN PUBLIC PLACES |
| Rev No |
1 |
Status |
N |
Date |
10-11-2022 |
|
|
Cont ID |
|
| Sent By |
swelter |
Date |
10-11-2022 |
Time |
14:02 |
Rev Time |
0.00 |
| Received By |
rrossano |
Date |
10-11-2022 |
Time |
14:02 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
01-19-2023 |
|
|
Cont ID |
|
| Sent By |
rbrown |
Date |
01-19-2023 |
Time |
20:18 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
01-19-2023 |
Time |
20:18 |
Sent To |
|
|
| Notes |
| 2023-01-19 20:19:49 | DEVELOPMENT SERVICES DEPARTMENT, BUILDING DIVISION, | | | COMMENTS: | | | | | | 1. THIS REVIEW IS A CURSORY REVIEW AS IT RELATES TO THE | | | SITE. IT IS NOT A REVIEW FOR FULL COMPLIANCE WITH | | | FLORIDA BUILDING CODE. THE FOLLOWING COMMENTS ARE TO BE | | | ADDRESSED FOR THE BUILDING PERMIT APPLICATION. | | | | | | 2. BUILDING SIZE. WHEN SUBMITTED FOR BUILDING PERMIT, | | | THE PLANS SHALL SHOW THAT THE TYPE OF CONSTRUCTION FOR | | | THE BUILDINGS WILL BE IN ACCORDANCE WITH THE HEIGHT, | | | AREA AND OCCUPANCY LIMITATIONS IN CHAPTER 5 OF THE | | | FLORIDA BUILDING CODE. | | | | | | 3. BUILDING LOCATION RELATIVE TO THE PROPERTY LINE AND | | | OTHER STRUCTURES. WHEN SUBMITTED FOR BUILDING PERMIT, | | | COMPLIANCE WITH ALL BUILDING SEPARATION, PERCENTAGE OF | | | OPENINGS AND OPENING PROTECTIVE REQUIREMENTS OF | | | CHAPTERS 6 AND 7 OF THE FLORIDA BUILDING CODE SHALL BE | | | VERIFIED. | | | | | | 4. SEPARATE PERMITS REQUIRED. ALL APPLICABLE PERMITS | | | AND SUB-PERMITS MUST BE OBTAINED BEFORE COMMENCING THE | | | WORK. SEPARATE PERMITS, PLANS AND FEES, ARE REQUIRED | | | FOR SIGNS, SWIMMING POOLS AND SPAS, GAS SYSTEMS, | | | GENERATORS, FIRE ALARM SYSTEMS, FIRE SPRINKLER AND | | | OTHER FIRE SUPPRESSION SYSTEMS, GREASE INTERCEPTORS, | | | SITE LIGHTING, SITE LANDSCAPE, SITE IRRIGATION, ETC. | | | | | | 5. BUILDING ADDRESS. EACH SEPARATE BUILDING, AND UNIT | | | WITH AN INDEPENDENT ENTRANCE FROM THE STREET, SHALL | | | HAVE A SEPARATE ADDRESS ASSIGNED BASED ON THE LOCATION | | | OF THE BUILDING ENTRANCE. FOR STREET ADDRESSING, | | | CONTACT CAROLINE PUELL, ADDRESSING COORDINATOR, AT | | | (561) 805 6659, OR BY EMAIL: [email protected] | | | | | | | | | ROBERT BROWN | | | BUILDING OFFICIAL | | | TEL: 561 805 6652 | | | EMAIL: [email protected] | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
10-12-2022 |
|
|
Cont ID |
|
| Sent By |
afowlkes |
Date |
10-11-2022 |
Time |
11:17 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
10-12-2022 |
Time |
21:49 |
Sent To |
|
|
| Notes |
| 2022-10-12 21:54:49 | DEVELOPMENT SERVICES DEPARTMENT, BUILDING DIVISION, | | | COMMENTS: | | | | | | 1. THIS REVIEW IS A CURSORY REVIEW AS IT RELATES TO THE | | | SITE. IT IS NOT A REVIEW FOR FULL COMPLIANCE WITH | | | FLORIDA BUILDING CODE. THE FOLLOWING COMMENTS ARE TO BE | | | ADDRESSED FOR THE BUILDING PERMIT APPLICATION. | | | | | | 2. LOCATION OF ACCESSIBLE PARKING SPACES. THE NORTH | | | ACCESSIBLE PARKING SPACE IS NOT THE CLOSEST SPACE TO | | | THE BUILDING ENTRANCE. IT IS LOCATED CLOSE TO STEPS AND | | | THERE ARE REGULAR PARKING SPACES THAT HAVE A SHORTER | | | TRAVEL DISTANCE TO THE BUILDING ENTRANCE. PER SECTION | | | 208.3 OF FLORIDA ACCESSIBILITY CODE, ACCESSIBLE PARKING | | | SPACES ARE TO BE LOCATED ON THE SHORTEST POSSIBLE ROUTE | | | OF TRAVEL FROM ADJACENT PARKING TO AN ACCESSIBLE | | | ENTRANCE. THE DESIGN OF ACCESSIBLE PARKING SPACES SHALL | | | COMPLY WITH SECTION 502 OF FLORIDA ACCESSIBILITY CODE | | | | | | 3. BUILDING SIZE. WHEN SUBMITTED FOR BUILDING PERMIT, | | | THE PLANS SHALL SHOW THAT THE TYPE OF CONSTRUCTION FOR | | | THE BUILDINGS WILL BE IN ACCORDANCE WITH THE HEIGHT, | | | AREA AND OCCUPANCY LIMITATIONS IN CHAPTER 5 OF THE | | | FLORIDA BUILDING CODE. | | | | | | 4. BUILDING LOCATION RELATIVE TO THE PROPERTY LINE AND | | | OTHER STRUCTURES. WHEN SUBMITTED FOR BUILDING PERMIT, | | | COMPLIANCE WITH ALL BUILDING SEPARATION, PERCENTAGE OF | | | OPENINGS AND OPENING PROTECTIVE REQUIREMENTS OF | | | CHAPTERS 6 AND 7 OF THE FLORIDA BUILDING CODE SHALL BE | | | VERIFIED. | | | | | | 5. SEPARATE PERMITS REQUIRED. ALL APPLICABLE PERMITS | | | AND SUB-PERMITS MUST BE OBTAINED BEFORE COMMENCING THE | | | WORK. SEPARATE PERMITS, PLANS AND FEES, ARE REQUIRED | | | FOR SIGNS, SWIMMING POOLS AND SPAS, GAS SYSTEMS, | | | GENERATORS, FIRE ALARM SYSTEMS, FIRE SPRINKLER AND | | | OTHER FIRE SUPPRESSION SYSTEMS, GREASE INTERCEPTORS, | | | SITE LIGHTING, SITE LANDSCAPE, SITE IRRIGATION, ETC. | | | | | | 6. BUILDING ADDRESS. EACH SEPARATE BUILDING, AND UNIT | | | WITH AN INDEPENDENT ENTRANCE FROM THE STREET, SHALL | | | HAVE A SEPARATE ADDRESS ASSIGNED BASED ON THE LOCATION | | | OF THE BUILDING ENTRANCE. FOR STREET ADDRESSING, | | | CONTACT CAROLINE PUELL, ADDRESSING COORDINATOR, AT | | | (561) 805 6659, OR BY EMAIL: [email protected] | | | | | | | | | ROBERT BROWN | | | BUILDING OFFICIAL | | | TEL: 561 805 6652 | | | EMAIL: [email protected] | | | |
|
|
| Review Stop |
ENG - PPRC |
ENGINEERING - PPRC |
| Rev No |
3 |
Status |
P |
Date |
02-08-2023 |
|
|
Cont ID |
|
| Sent By |
rrossano |
Date |
02-08-2023 |
Time |
|
Rev Time |
0.00 |
| Received By |
rrossano |
Date |
02-08-2021 |
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
ENG - PPRC |
ENGINEERING - PPRC |
| Rev No |
2 |
Status |
F |
Date |
01-04-2023 |
|
|
Cont ID |
|
| Sent By |
rrossano |
Date |
01-04-2023 |
Time |
|
Rev Time |
0.00 |
| Received By |
rrossano |
Date |
01-04-2023 |
Time |
|
Sent To |
|
|
| Notes |
| 2023-01-04 18:22:58 | Z22090021 - GRAMERCY PARK RESUB 1.4.23 | | | | | | COMMENTS FROM RICK ROSSANO, SR. PROJECT COORDINATOR, | | | ENGINEERING SERVICES AT 561-494-1098 [email protected] | | | GENERAL: | | | O PLEASE RESPOND TO ALL COMMENTS IN WRITING, AND | | | INCLUDE PROJECT NAME, ADDRESS AND PERMIT NUMBER | | | (Z-XXXXXXXX). | | | O THE CITY OF WEST PALM BEACH HAS A NUMBER OF | | | REGULATIONS AND PERMIT REQUIREMENTS WHICH DIRECTLY | | | AFFECT THE DEVELOPMENT AND INSTALLATION OF WATER AND | | | WASTEWATER UTILITIES WITHIN THE CITY. PLEASE SEE | | | DEVELOPMENT PERMIT SUBMITTAL REQUIREMENTS AT THE LINK | | | BELOW: | | | A. HTTP://WPB.ORG/CMSPAGES/GETAMAZONFILE.ASPX?PATH=~\WP | | | B_WEBSITE\MEDIA\ENGINEERING\DEVELOPMENT-APPLICATION-FUL | | | L-PACKAGE_2016.PDF&HASH=7BD4DD7EB6115181D8C5977BCC02A97 | | | B1960045731D3658206F27451722716EF | | | B. THIS AND OTHER RELATED ENGINEERING DOCUMENTS CAN BE | | | FOUND HERE: | | | HTTP://WPB.ORG/DEPARTMENTS/ENGINEERING-PUBLIC-WORKS/FOR | | | MS,-PERMITS-APPLICATIONS | | | C. ALSO SEE: CODE OF ORDINANCES, CITY OF WEST PALM | | | BEACH, FLORIDA, CODIFIED THROUGH ORD. NO. 4183-08, | | | ADOPTED SEPT. 22, 2008. (SUPPLEMENT NO. 18) | | | CHAPTER 90 UTILITIES, ARTICLE I. IN GENERAL, | | | SEC. 90-7. POLICY REGARDING EXTENSION OF WATER OR SEWER | | | SERVICE FACILITIES OF THE CITY. | | | THE WATER AND WASTEWATER SERVICE AGREEMENTS AND THE | | | CONSTRUCTION PERMITS ADDRESS RESERVATION OF CAPACITY | | | BASED ON USAGE, METER SIZE AND FEES, DESIGN STANDARDS, | | | BACKFLOW PREVENTION, FIRE SERVICE AND IRRIGATION. | | | O AS OF DECEMBER 20, 2015, THE CITY OF WEST PALM BEACH | | | CROSS-CONNECTION CONTROL MANUAL HAS BEEN REVISED, | | | STATING "ALL BACKFLOW DEVICES MUST BE LEAD-FREE". FOR | | | MORE INFORMATION, REFER TO THE LINK BELOW: | | | A. HTTP://WPB.ORG/DEPARTMENTS/PUBLIC-UTILITIES/FORMS-PU | | | BLICATIONS/BACKFLOW-CROSS-CONNECTION- CONTROL-MANUAL | | | O PLEASE SUBMIT A FORMAL AS-BUILT REQUEST FOR ALL CITY | | | OF WEST PALM BEACH-OWNED UTILITIES WITHIN THE PUBLIC | | | RIGHT OF WAY FOR THE ENTIRE EXTENT OF THE LIMITS OF | | | YOUR PROJECT. IDENTIFY TYPE OF UTILITY, LOCATION, PIPE | | | MATERIAL, AGE AND SIZE. PLEASE CONTACT JANICE TARBILL | | | IN THE WPB ENGINEERING SERVICES DEPARTMENT AT | | | [email protected] OR 561-494-1079 FOR FURTHER | | | ASSISTANCE. NOTE THAT FIELD RECORDS ARE FOR INFORMATION | | | ONLY. FIELD VERIFY UTILITY LOCATIONS USING FIELD | | | SURVEY, POT-HOLING, SOFT DIGS ETC. | | | O PROVIDE EXISTING AND PROPOSED PERVIOUS AND IMPERVIOUS | | | DATA. | | | | | | BACKFLOW ASSEMBLY AND METERS: | | | O SHOW AND LABEL ANY EXISTING OR PROPOSED WATER | | | SERVICES AND WATER METERS, ALONG WITH WHAT IS HAPPENING | | | TO THEM. | | | O SHOW EXISTING AND PROPOSED DEDICATED UTILITY | | | EASEMENTS TO ALLOW ACCESS FOR CITY PERSONNEL TO | | | PROPOSED UTILITY WATER METERS. VERIFY THAT THERE ARE NO | | | STRUCTURES WITHIN EASEMENT. | | | O PROVIDE ENLARGED VIEW ON PLANS OF PROPOSED LOCATION | | | OF WATER METER AND BACKFLOW | | | PREVENTION. | | | O BACKFLOWS SHALL BE INSTALLED ON PRIVATE PROPERTY | | | OUTSIDE OF EASEMENTS AND RIGHTS OF WAY. DOMESTIC WATER | | | METERS SHALL BE INSTALLED IMMEDIATELY ADJACENT TO | | | PROPERTY LINE. 3 INCH AND LARGER WATER METERS SHALL BE | | | INSTALLED ABOVE-GROUND ONLY. | | | O CALLOUT DOMESTIC BACKFLOW PREVENTER AS RPPA (MAKE | | | NOTE USC APPROVED) AND FIRE BACKFLOW PREVENTER AS DCDA. | | | | | | WATER/WASTEWATER PLAN: | | | O PROVIDE VERTICAL DATUM AND DATUM CONVERSION | | | INFORMATION (NAVD 1988 AND NGVD 1929). | | | O SHOW PROJECT ADDRESS ON ALL PLAN SHEETS. | | | O PROVIDE LEGEND ON ALL PLAN SHEETS TO INCLUDE | | | STREETLIGHT, SIGN POSTS, TRANSFORMER BOXES ETC. | | | O PLANS SHALL SHOW EXISTING AND PROPOSED LOCATIONS AND | | | DIMENSIONS OF ALL WATER, STORMWATER, AND SANITARY AND | | | SEWER LINES AND CLEANOUTS, INCLUDING STUBS TO EACH | | | PROPERTY LINE FOR WATER AND SANITARY SEWERS, THE MAKE | | | AND MODEL OF ALL VALVES, POTABLE AND IRRIGATION METERS, | | | BACKFLOWS, FIRE HYDRANTS AND FDCS, AND OTHER DEVICES TO | | | BE INSTALLED ON THE SYSTEM, CATCH BASINS, CULVERTS, | | | DITCHES INCLUDING GRADES, PIPES SIZES, MATERIALS, | | | ELEVATIONS, ASSUMPTIONS, CALCULATIONS, INVERT | | | ELEVATIONS FOR ALL INLETS AND MANHOLES AND PROFILES OF | | | SANITARY SEWER LINES. | | | O GATE VALVE BOXES SHALL NOT BE INSTALLED IN CURB OR | | | SIDEWALK. ALL AVAILABLE ELEVATION SHALL BE SHOWN ON THE | | | PROFILE VIEW. | | | O DIRECTION OF FLOW SHALL BE SHOWN ON PLAN VIEW ON PLAN | | | VIEW FOR ALL SANITARY AND STORM SEWERS. | | | O SHOW SLOPE % ON ALL SANITARY LINES AND CALL OUT | | | MATERIAL. | | | O PLAN VIEW SHALL SHOW ALL EXISTING AND PROPOSED | | | UNDERGROUND UTILITY LAYOUT, INCLUDING FIBER OPTIC, | | | ELECTRIC, GAS, AND CABLEVISION & TELECOMMUNICATION | | | FACILITIES INCLUDING PIPE SIZE AND MATERIAL LOCATED IN | | | THE RIGHT-OF-WAY. | | | O PROVIDE PROFILE AND CLEARANCES BETWEEN WATER, SEWER | | | AND STORM LINES PER CITY OF WEST PALM BEACH STANDARD | | | DETAIL GN-2 SERIES, AT ALL UTILITY CROSSINGS. PLEASE | | | INCLUDE FIBER OPTIC, ELECTRIC, GAS, AND CABLEVISION & | | | TELECOMMUNICATION FACILITIES INCLUDING PIPE SIZE AND | | | MATERIAL LOCATED IN THE RIGHT-OF-WAY. | | | O SUBMIT COMPLETED LOS ANALYSIS SUMMARY TABLE DIRECTLY | | | TO ENGINEERING (SHEET 33 OF CITY OF WPB DEVELOPMENT | | | APPLICATION). PROVIDE CALCULATIONS ON PLANS OF EXISTING | | | AND PROPOSED DEMANDS FOR WATER & SEWER (AVERAGE, | | | MAXIMUM AND PEAK) AND FIRE FLOW DEMANDS. CALCULATIONS | | | SHALL BE PER FAC 64E-6 FOR SEWER AND PER FAC 64-E.008 | | | FOR WATER. | | | O PROVIDE FIRE FLOW TEST DATA. | | | O CUT AND CAP UTILITIES NOT IN USE AND REMOVE ANY | | | ABANDONED UTILITY LINES LARGER THAN 2 INCHES FROM CITY | | | ROW. | | | O LABEL WATER LINES AS PRIVATE WHERE APPLICABLE. | | | O PLEASE SHOW AND LABEL EXISTING AND PROPOSED GREASE | | | TRAPS (IF ANY). | | | O PER CITY STANDARDS MAINTAIN MINIMUM DISTANCE BETWEEN | | | OUTSIDE DIAMETER OF CITY PIPE AND ROOT BARRIER. | | | | | | QUESTIONS AND COORDINATION CONTACTS: | | | O MARK HURLEY, FIELD CUSTOMER SERVICE SUPERVISOR WITH | | | CITY OF WPB PUBLIC UTILITIES, REGARDING PLACEMENT OF | | | BACKFLOW DEVICES AND WATER METERS. CONTACT HIM AT | | | 561-822-2262 OR [email protected] | | | O COMMENTS FROM MIKE TECHNOW, PUB. UTILITIES ENGINEER, | | | [email protected], 561-494-1047: | | | O COMMENTS FROM RICKY ELIZONDO, PUB. UTILITIES PLANS | | | EXAMINER, [email protected] , 561-494-1101: | | | O COMMENTS FROM TRACY WARD, SR. STORMWATER ENGINEER, | | | ENG. SERVICES DEPT. AT 561-494-1120 OR [email protected] | | | |
|
|
| Review Stop |
ENG - PPRC |
ENGINEERING - PPRC |
| Rev No |
1 |
Status |
P |
Date |
09-26-2022 |
|
|
Cont ID |
|
| Sent By |
rrossano |
Date |
09-26-2022 |
Time |
|
Rev Time |
|
| Received By |
rrossano |
Date |
09-26-2022 |
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
01-04-2023 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
01-04-2023 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
01-04-2023 |
Time |
15:41 |
Sent To |
|
|
| Notes |
| 2023-01-04 15:41:45 | 2ND REVIEW RESPONSE | | | | | | AFTER A REVIEW OF THE PPRC RESPONSE PACKET FOR THIS | | | PROJECT, THE PREVIOUSLY SUBMITTED FIRE PREVENTION | | | BUREAU COMMENTS APPEAR TO HAVE BEEN ADDRESSED. | | | | | | HOWEVER, THE BUREAU'S APPROVAL OF THIS SUBMITTED | | | PROJECT DOES NOT CONSTITUTE ITS FINAL REVIEW OR | | | APPROVAL. | | | | | | THE BUREAU SHALL REVIEW ALL SUBMITTED BUILDING PLANS AT | | | THE APPROPRIATE TIME AND IN ACCORDANCE WITH THE | | | REQUIREMENTS OF ALL APPLICABLE CODES AND STANDARDS. | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | WEST PALM BEACH FIRE DEPARTMENT | | | 561-804-4709 | | | [email protected] | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
09-29-2022 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
09-29-2022 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
09-29-2022 |
Time |
15:11 |
Sent To |
|
|
| Notes |
| 2022-09-29 15:14:46 | THE FOLLOWING COMMENTS WERE SUBMITTED BY PETER LEDUC, | | | FIRE MARSHAL, BUREAU OF FIRE PREVENTION, WEST PALM | | | BEACH FIRE DEPARTMENT. | | | | | | THIS REVIEW CAN ONLY BE CONSIDERED PRELIMINARY AS THE | | | DRAWINGS THAT WERE REVIEWED WERE NOT COMPLETE. | | | ADDITIONAL COMMENTS CAN BE EXPECTED WHEN FULL DRAWINGS | | | ARE SUBMITTED FOR PERMIT. | | | | | | THE FIRE PREVENTION BUREAU HAS NO OBJECTIONS TO THE | | | PROPOSED PROJECT. THE FOLLOWING COMMENTS ARE INTENDED | | | TO PROVIDE GUIDANCE FOR BUILDING PLAN SUBMITTAL. | | | | | | 1. CONSTRUCTION, DEMOLITION, AND RENOVATION TO COMPLY | | | WITH NFPA 241. EXTRA ATTENTION SHALL BE GIVEN TO THE | | | PERMITTING AND LOCATION OF CONSTRUCTION TRAILERS. A | | | PERMIT IS REQUIRED FOR ANY CONSTRUCTION TRAILER RELATED | | | TO THIS PROJECT. SEPARATION DISTANCES FROM MAIN | | | STRUCTURES AS WELL AS OTHER TRAILERS SHALL BE CLOSELY | | | MONITORED FOR THE REQUIREMENTS OF FIRE SPRINKLER | | | PROTECTION. | | | | | | 2. SITE ACCESS AND EXIT POINTS ARE TO BE CLEARLY | | | IDENTIFIED AND MAINTAINED FOR EMERGENCY VEHICLES DURING | | | ALL CONSTRUCTION ACTIVITIES. | | | | | | 3. THE BUILDING ADDRESS SHALL BE CLEARLY VISIBLE FROM | | | ALL ACCESS ROADWAYS, INCLUDING DURING CONSTRUCTION. | | | ADDRESS NUMBERS SHALL CONTRAST WITH THEIR BACKGROUND | | | AND SHALL NOT BE LESS THAN SIX (6) INCHES IN HEIGHT | | | WITH A ONE (1) INCH STROKE FOR ALL BUILDINGS. | | | | | | 4. DURING CONSTRUCTION, TRASH AND DEBRIS IS TO BE | | | REMOVED FROM THE SITE DAILY OR MORE OFTEN TO REDUCE THE | | | ACCUMULATION OF POTENTIAL LIFE AND FIRE SAFETY HAZARDS. | | | | | | 5. THE CONSTRUCTION OF THE BUILDING(S) SHALL COMPLY | | | WITH THE 7TH EDITION OF THE FLORIDA FIRE PREVENTION | | | CODE, INCLUDING NFPA 1 & 101, AND ALL ASSOCIATED FIRE | | | CODES. | | | | | | 6. FOR PLAN REVIEW SUBMITTAL, PLEASE INCLUDE THE | | | OCCUPANCY TYPE PER THE FLORIDA FIRE PREVENTION CODE. | | | | | | 7. FOR PLAN REVIEW SUBMITTAL, PLEASE ENSURE THAT A FIRE | | | LOAD CALCULATION IS INCLUDED, AND THAT ADEQUATE WATER | | | SUPPLY IS EXISTING OR WILL BE PROVIDED. | | | | | | 8. ALL EXISTING AND NEW FIRE HYDRANTS PLANNED FOR THIS | | | DEVELOPMENT SHALL BE CLEARLY INDICATED AND IDENTIFIED | | | ON THE PLAN AND CLOSELY COORDINATED WITH THE BUREAU OF | | | FIRE PREVENTION. | | | | | | THE WAS NO INDICATION OF A FDC. | | | | | | THE PROPOSED LOCATION OF THE FIRE HYDRANT AND FDC SHALL | | | BE WITHIN 100' OF EACH OTHER AND CLOSELY COORDINATED | | | WITH THE BUREAU OF FIRE PREVENTION. | | | | | | 9. PROVIDE FOR A FIRE SPRINKLER AND/OR FIRE ALARM PER | | | THE APPLICABLE OCCUPANCY CODE. FOR ANY LIFE SAFETY | | | ENGINEERED SYSTEM, I.E FIRE SPRINKLER AND FIRE ALARM, | | | ENSURE THEY COMPLY WITH THE REQUIREMENTS OF F.A.C. 61G | | | AND SUBMITTED WITH THE MASTER PERMIT. | | | | | | 9A. THE LOCATION OF ANY APPLICABLE DDCV AND FIRE LINE | | | LOCATIONS SHALL MEET AND BE INSTALLED PER THE | | | REQUIREMENTS OF NFPA 24 AND SHALL BE COORDINATED WITH | | | THE OFFICE OF FIRE MARSHAL, THE CITY'S ENGINEERS | | | OFFICE, THE LANDSCAPE PLANNER, AND THE CITY'S PLANNING | | | AND ZONING OFFICE. | | | | | | 10. COMPLETE LIFE SAFETY PLANS FOR THE OCCUPANCY SHALL | | | BE PROVIDED THAT ILLUSTRATE OCCUPANT LOADS, TRAVEL | | | DISTANCES, EXIT SEPARATION DISTANCES, COMMON PATHS OF | | | TRAVEL, DEAD-END CORRIDORS, EXIT SIGNS, EMERGENCY | | | LIGHTING, EXITS LEADING TO A PUBLIC WAY, FIRE | | | EXTINGUISHER LOCATIONS, AND ALL FIRE SAFETY FEATURES | | | AND EQUIPMENT. | | | | | | 11. IT IS HIGHLY RECOMMENDED (REQUIRED WITH FIRE | | | SPRINKLER SYSTEM) THAT A KNOX BOX WITH KEYS FOR ENTRY | | | DOOR LOCKS BE PROVIDED FOR 24 HOUR EMERGENCY ACCESS. | | | | | | 12. TWO-WAY RADIO COMMUNICATIONS ENHANCEMENT SYSTEMS. | | | | | | NFPA 1, CHAPTER 11, BUILDING SERVICES; 11.10 TWO-WAY | | | RADIO ENHANCEMENT SERVICES. | | | 11.10.1 IN ALL NEW AND EXISTING BUILDINGS, MINIMUM | | | RADIO SIGNAL STRENGTH FOR FIRE DEPARTMENT | | | COMMUNICATIONS SHALL BE MAINTAINED AT A LEVEL | | | DETERMINED BY THE AHJ. | | | | | | SHOULD THERE BE POOR FD RADIO COMMUNICATIONS, YOU WILL | | | NEED TO CONTACT MARK FILLA, PALM BEACH COUNTY PUBLIC | | | SAFETY RADIO SYSTEMS MANAGER, [email protected], | | | 561-233-0837; AS OUR RADIOS OPERATE ON THEIR SYSTEM FOR | | | DETAILED RADIO FREQUENCY AND INSTALLATION INSTRUCTIONS. | | | | | | 13. THE BUREAU'S APPROVAL OF THIS SUBMITTED PROJECT | | | DOES NOT CONSTITUTE ITS FINAL REVIEW OR APPROVAL. | | | | | | 14. THE BUREAU SHALL REVIEW ALL SUBMITTED BUILDING | | | PLANS AT THE APPROPRIATE TIME AND IN ACCORDANCE WITH | | | THE REQUIREMENTS OF ALL APPLICABLE CODES AND STANDARDS. | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
3 |
Status |
P |
Date |
02-09-2023 |
|
|
Cont ID |
|
| Sent By |
rcaranci |
Date |
02-09-2023 |
Time |
15:35 |
Rev Time |
0.00 |
| Received By |
rcaranci |
Date |
02-09-2023 |
Time |
15:35 |
Sent To |
|
|
| Notes |
| 2023-02-09 15:36:18 | FROM: RAY CARANCI, SENIOR LANDSCAPE PLANNER | | | 561-822-1462 | | | PROJECT: GRAMERCY PARK PBC Z22090021 | | | FEBRUARY 9, 2023 | | | I HAVE REVIEWED THE ABOVE REFERENCED PETITION, AND | | | PROVIDE THE FOLLOWING COMMENTS: | | | | | | | | | 1. SATISFIED. THE NORTHERN PORTION OF THE PARK IS | | | CONSERVATION ZONING. THIS LIMITS THE ACTIONS THAT CAN | | | BE TAKEN WITHIN THIS AREA. PER THE CONSERVATION ELEMENT | | | OF THE COMPREHENSIVE PLAN AND SECTIONS 94-373 AND | | | 94-377 OF THE ZONING AND LAND DEVELOPMENT REGULATIONS | | | AN ENVIRONMENTAL ASSESSMENT WOULD BE REQUIRED PRIOR TO | | | APPROVAL OF ANY DEVELOPMENT WITHIN THIS PARCEL TO | | | DETERMINE THE CLASSIFICATION AND CONDITION OF THE | | | ECOSYSTEM AND IDENTIFY ANY THREATENED, ENDANGERED OR | | | RARE SPECIES. THE PASSIVE MULCH PATH ROUTED AROUND ANY | | | EXISTING TREES AND THE REMOVAL OF PROHIBITED INVASIVE | | | EXOTIC SPECIES WOULD BE THE ONLY MODIFICATIONS ALLOWED | | | WITHOUT THIS VERIFICATION. | | | 2. SATISFIED. SECTION 94-448 (D)(3) REQUIRES NATIVE | | | TREES AND PALMS IN GOOD CONDITION TO BE PRESERVED ON | | | SITE OR RELOCATED. ANSI A 300 (PART 5) STANDARDS | | | SPECIFY EXAMPLES OF SUITABILITY RATINGS OF GOOD, | | | MODERATE, OR POOR FOR RELOCATION. PROVIDE AN ARBORISTS | | | REPORT RATING THE CONDITION AND RELOCATION POTENTIAL | | | FOR THE NATIVE TREES PROPOSED TO BE REMOVED. LIVE OAK | | | TREES SHOULD BE RELOCATED. | | | THE 6 LIVE OAK TREES ARE LISTED IN GOOD CONDITION BUT | | | ARE INDICATED AS BEING REMOVED. | | | STAFF MUST HAVE AN ARBORISTS REPORT DOCUMENTING WHY THE | | | TREES CANNOT BE RELOCATED. | | | 3. MAKE THE FOLLOWING CORRECTIONS TO THE TREE | | | DISPOSITION LIST: | | | ??? SATISFIED. PROVIDE THE CANOPY DIAMETER IN FEET FOR | | | ANY PROPOSED REMOVALS. LIVE OAK, SILVER BUTTONWOOD, | | | SLASH PINE AND DAHOON HOLLY. | | | ??? SATISFIED. THE KEY FOR THE RELOCATES AND REMOVALS | | | IS NOT CLEAR. REMOVALS SHOULD BE SHOWN WITH AN X TO | | | CLEARLY INDICATE PROPOSED REMOVAL. | | | ??? SATISFIED. PROVIDE THE METHODOLOGY FOR THE | | | DETERMINATION OF TREES TO BE SURVEYED AND INVENTORIED | | | WITHIN THE CONSERVATION ZONING PORTION. | | | 4. SATISFIED. IDENTIFY RELOCATED TREES OR PALMS ON THE | | | PLANT LIST AND COUNT THEM TOWARD THE REQUIRED TREES. | | | ADD THE 12 SABAL PALMS AS RELOCATES TO THE PLANT LIST. | | | IF ANY OTHER TREES ARE TO BE RELOCATED, THEY MUST ALSO | | | BE LISTED IN A SECTION ON THE PLANT LIST. | | | | | | 5. SATISFIED. SILVER BUTTONWOOD, BLACK IRONWOOD AND | | | TABEBUIA TREES MUST MEET THE MINIMUM 12 FOOT HEIGHT | | | REQUIREMENT. | | | | | | 6. SATISFIED. SUGGEST THAT THE FENCE BE PLACED AT THE | | | PROPERTY LINE INSTEAD OF 5 FEET INSIDE THE PROPERTY | | | LINE. | | | | | | 7. SATISFIED. PARKING IS NOT ALLOWED WITHIN THE | | | CONSERVATION ZONING DESIGNATION. THE DUMPSTER ENCLOSURE | | | MUST ALSO BE ADJUSTED TO BE WITHIN THE ROS DESIGNATED | | | PARCEL. | | | | | | 8. SATISFIED. PER SECTION 94-443(C), TERMINAL LANDSCAPE | | | ISLANDS ARE REQUIRED AT THE END OF EACH ROW OF PARKING. | | | THERE ARE 2 LOCATIONS OF NEW PARKING THAT DO NOT HAVE | | | THE REQUIRED TERMINAL ISLAND OR REQUIRED SHADE TREE. | | | | | | 9. SATISFIED. SECTION 94-443(C)(3) REQUIRES THAT A | | | MINIMUM OF 75 PERCENT OF ALL TREES THAT ARE REQUIRED TO | | | BE PLANTED WITHIN THE INTERIOR OF AN OFF STREET PARKING | | | AREA SHALL BE CATEGORY 1 SHADE TREES. SHOW THE | | | PERCENTAGE OF CATEGORY 1 TREES PROVIDED FOR THE | | | REQUIRED LANDSCAPE AREAS. | | | | | | | | | 10. SATISFIED. SHOW ALL EXISTING AND PROPOSED WATER AND | | | SEWER AND DRAINAGE LINES ON THE LANDSCAPE PLAN. SHOW | | | LOCATIONS OF BACKFLOWS AND ADJUST LOCATIONS OF UTILITY | | | LINES TO RESOLVE CONFLICTS WITH EXISTING AND PROPOSED | | | TREES AND LANDSCAPING. | | | | | | 11. SATISFIED. SHOW COMPLIANCE WITH SECTION 94-445 L. | | | PLANT SPECIES. A MINIMUM OF 60 PERCENT OF PLANT | | | MATERIAL ADDED SHALL BE FLORIDA NATIVE OR DROUGHT | | | TOLERANT SPECIES SELECTED FROM THE CITY LIST OR THE | | | LIST OF SPECIES IN THE MOST RECENT EDITION OF SOUTH | | | FLORIDA WATER MANAGEMENT DISTRICT WATERWISE SOUTH | | | FLORIDA LANDSCAPES. PROVIDE THE ACTUAL PERCENTAGE BASED | | | ON THE PLANT LIST. | | | | | | 12. SATISFIED. PROVIDE SCREENING HEDGES AND SHOW | | | LOCATIONS FOR ALL GROUND MOUNTED VALVES AND EQUIPMENT | | | AND ADD A NOTE THAT ALL EQUIPMENT WILL BE SCREENED. | | | SHOW SCREENING HEDGES WHERE POSSIBLE TO ACCOUNT FOR THE | | | ADDITIONAL PLANT MATERIAL REQUIRED. THE DUMPSTER | | | ENCLOSURE MUST SHOW THE REQUIRED HEDGE ON THE 3 NON | | | ACCESS SIDES. | | | | | | ADDITIONAL COMMENTS 12/21/22: | | | | | | 13. SATISFIED. UPDATE THE FLORIDA FRIENDLY DESIGN | | | OPTIONS CHART TO THE CURRENT CODE LANGUAGE AND ADJUST | | | POINTS. #7 DOES NOT APPLY. | | | | | | 14. SATISFIED. CORRECT NOTE ON SHEET LP-2 REGARDING | | | SHADED TREES FOR RELOCATION INSTEAD OF REMOVAL. | | | | | | | | | CONDITIONS OF APPROVAL | | | 1. PRIOR TO THE REMOVAL OR RELOCATION OF ANY TREES ON | | | THE PROPERTY, A TREE ALTERATION PERMIT SHALL BE | | | SUBMITTED, REVIEWED AND APPROVED BY THE DEVELOPMENT | | | SERVICES DEPARTMENT, PLANNING DIVISION. | | | |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
2 |
Status |
F |
Date |
12-21-2022 |
|
|
Cont ID |
|
| Sent By |
rcaranci |
Date |
12-21-2022 |
Time |
15:41 |
Rev Time |
0.00 |
| Received By |
rcaranci |
Date |
12-21-2022 |
Time |
15:41 |
Sent To |
|
|
| Notes |
| 2022-12-21 15:41:36 | FROM: RAY CARANCI, SENIOR LANDSCAPE PLANNER | | | 561-822-1462 | | | PROJECT: GRAMERCY PARK PBC Z22090021 | | | DECEMBER 21, 2022 | | | I HAVE REVIEWED THE ABOVE REFERENCED PETITION, AND | | | PROVIDE THE FOLLOWING COMMENTS: | | | | | | | | | 1. SATISFIED. THE NORTHERN PORTION OF THE PARK IS | | | CONSERVATION ZONING. THIS LIMITS THE ACTIONS THAT CAN | | | BE TAKEN WITHIN THIS AREA. PER THE CONSERVATION ELEMENT | | | OF THE COMPREHENSIVE PLAN AND SECTIONS 94-373 AND | | | 94-377 OF THE ZONING AND LAND DEVELOPMENT REGULATIONS | | | AN ENVIRONMENTAL ASSESSMENT WOULD BE REQUIRED PRIOR TO | | | APPROVAL OF ANY DEVELOPMENT WITHIN THIS PARCEL TO | | | DETERMINE THE CLASSIFICATION AND CONDITION OF THE | | | ECOSYSTEM AND IDENTIFY ANY THREATENED, ENDANGERED OR | | | RARE SPECIES. THE PASSIVE MULCH PATH ROUTED AROUND ANY | | | EXISTING TREES AND THE REMOVAL OF PROHIBITED INVASIVE | | | EXOTIC SPECIES WOULD BE THE ONLY MODIFICATIONS ALLOWED | | | WITHOUT THIS VERIFICATION. | | | 2. PARTIALLY SATISFIED. SECTION 94-448 (D)(3) REQUIRES | | | NATIVE TREES AND PALMS IN GOOD CONDITION TO BE | | | PRESERVED ON SITE OR RELOCATED. ANSI A 300 (PART 5) | | | STANDARDS SPECIFY EXAMPLES OF SUITABILITY RATINGS OF | | | GOOD, MODERATE, OR POOR FOR RELOCATION. PROVIDE AN | | | ARBORISTS REPORT RATING THE CONDITION AND RELOCATION | | | POTENTIAL FOR THE NATIVE TREES PROPOSED TO BE REMOVED. | | | LIVE OAK TREES SHOULD BE RELOCATED. | | | THE 6 LIVE OAK TREES ARE LISTED IN GOOD CONDITION BUT | | | ARE INDICATED AS BEING REMOVED. | | | STAFF MUST HAVE AN ARBORISTS REPORT DOCUMENTING WHY THE | | | TREES CANNOT BE RELOCATED. | | | 3. MAKE THE FOLLOWING CORRECTIONS TO THE TREE | | | DISPOSITION LIST: | | | ??? SATISFIED. PROVIDE THE CANOPY DIAMETER IN FEET FOR | | | ANY PROPOSED REMOVALS. LIVE OAK, SILVER BUTTONWOOD, | | | SLASH PINE AND DAHOON HOLLY. | | | ??? SATISFIED. THE KEY FOR THE RELOCATES AND REMOVALS | | | IS NOT CLEAR. REMOVALS SHOULD BE SHOWN WITH AN X TO | | | CLEARLY INDICATE PROPOSED REMOVAL. | | | ??? SATISFIED. PROVIDE THE METHODOLOGY FOR THE | | | DETERMINATION OF TREES TO BE SURVEYED AND INVENTORIED | | | WITHIN THE CONSERVATION ZONING PORTION. | | | 4. NOT SATISFIED. IDENTIFY RELOCATED TREES OR PALMS ON | | | THE PLANT LIST AND COUNT THEM TOWARD THE REQUIRED | | | TREES. | | | ADD THE 12 SABAL PALMS AS RELOCATES TO THE PLANT LIST. | | | IF ANY OTHER TREES ARE TO BE RELOCATED, THEY MUST ALSO | | | BE LISTED IN A SECTION ON THE PLANT LIST. | | | | | | 5. SATISFIED. SILVER BUTTONWOOD, BLACK IRONWOOD AND | | | TABEBUIA TREES MUST MEET THE MINIMUM 12 FOOT HEIGHT | | | REQUIREMENT. | | | | | | 6. SATISFIED. SUGGEST THAT THE FENCE BE PLACED AT THE | | | PROPERTY LINE INSTEAD OF 5 FEET INSIDE THE PROPERTY | | | LINE. | | | | | | 7. SATISFIED. PARKING IS NOT ALLOWED WITHIN THE | | | CONSERVATION ZONING DESIGNATION. THE DUMPSTER ENCLOSURE | | | MUST ALSO BE ADJUSTED TO BE WITHIN THE ROS DESIGNATED | | | PARCEL. | | | | | | 8. SATISFIED. PER SECTION 94-443(C), TERMINAL LANDSCAPE | | | ISLANDS ARE REQUIRED AT THE END OF EACH ROW OF PARKING. | | | THERE ARE 2 LOCATIONS OF NEW PARKING THAT DO NOT HAVE | | | THE REQUIRED TERMINAL ISLAND OR REQUIRED SHADE TREE. | | | | | | 9. SATISFIED. SECTION 94-443(C)(3) REQUIRES THAT A | | | MINIMUM OF 75 PERCENT OF ALL TREES THAT ARE REQUIRED TO | | | BE PLANTED WITHIN THE INTERIOR OF AN OFF STREET PARKING | | | AREA SHALL BE CATEGORY 1 SHADE TREES. SHOW THE | | | PERCENTAGE OF CATEGORY 1 TREES PROVIDED FOR THE | | | REQUIRED LANDSCAPE AREAS. | | | | | | | | | 10. SATISFIED. SHOW ALL EXISTING AND PROPOSED WATER AND | | | SEWER AND DRAINAGE LINES ON THE LANDSCAPE PLAN. SHOW | | | LOCATIONS OF BACKFLOWS AND ADJUST LOCATIONS OF UTILITY | | | LINES TO RESOLVE CONFLICTS WITH EXISTING AND PROPOSED | | | TREES AND LANDSCAPING. | | | | | | 11. SATISFIED. SHOW COMPLIANCE WITH SECTION 94-445 L. | | | PLANT SPECIES. A MINIMUM OF 60 PERCENT OF PLANT | | | MATERIAL ADDED SHALL BE FLORIDA NATIVE OR DROUGHT | | | TOLERANT SPECIES SELECTED FROM THE CITY LIST OR THE | | | LIST OF SPECIES IN THE MOST RECENT EDITION OF SOUTH | | | FLORIDA WATER MANAGEMENT DISTRICT WATERWISE SOUTH | | | FLORIDA LANDSCAPES. PROVIDE THE ACTUAL PERCENTAGE BASED | | | ON THE PLANT LIST. | | | | | | 12. PARTIALLY SATISFIED. PROVIDE SCREENING HEDGES AND | | | SHOW LOCATIONS FOR ALL GROUND MOUNTED VALVES AND | | | EQUIPMENT AND ADD A NOTE THAT ALL EQUIPMENT WILL BE | | | SCREENED. | | | SHOW SCREENING HEDGES WHERE POSSIBLE TO ACCOUNT FOR THE | | | ADDITIONAL PLANT MATERIAL REQUIRED. THE DUMPSTER | | | ENCLOSURE MUST SHOW THE REQUIRED HEDGE ON THE 3 NON | | | ACCESS SIDES. | | | | | | ADDITIONAL COMMENTS 12/21/22: | | | | | | 13. UPDATE THE FLORIDA FRIENDLY DESIGN OPTIONS CHART TO | | | THE CURRENT CODE LANGUAGE AND ADJUST POINTS. #7 DOES | | | NOT APPLY. | | | | | | 14. CORRECT NOTE ON SHEET LP-2 REGARDING SHADED TREES | | | FOR RELOCATION INSTEAD OF REMOVAL. | | | | | | | | | CONDITIONS OF APPROVAL | | | 1. PRIOR TO THE REMOVAL OR RELOCATION OF ANY TREES ON | | | THE PROPERTY, A TREE ALTERATION PERMIT SHALL BE | | | SUBMITTED, REVIEWED AND APPROVED BY THE DEVELOPMENT | | | SERVICES DEPARTMENT, PLANNING DIVISION. | | | |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
1 |
Status |
F |
Date |
10-06-2022 |
|
|
Cont ID |
|
| Sent By |
rcaranci |
Date |
10-06-2022 |
Time |
11:28 |
Rev Time |
0.00 |
| Received By |
rcaranci |
Date |
10-06-2022 |
Time |
11:28 |
Sent To |
|
|
| Notes |
| 2022-10-06 11:30:57 | FROM: RAY CARANCI, SENIOR LANDSCAPE PLANNER | | | 561-822-1462 | | | PROJECT: 2235 OKEECHOBEE Z22090021 | | | OCTOBER 6, 2022 | | | I HAVE REVIEWED THE ABOVE REFERENCED PETITION, AND | | | PROVIDE THE FOLLOWING COMMENTS: | | | | | | 1. PROVIDE A TREE DISPOSITION AND MITIGATION LIST. | | | SECTION 94-448 (D)(3) REQUIRES NATIVE TREES IN GOOD | | | CONDITION TO BE PRESERVED ON SITE OR RELOCATED. ANSI A | | | 300 (PART 5) STANDARDS SPECIFY EXAMPLES OF SUITABILITY | | | RATINGS OF GOOD, MODERATE, OR POOR FOR RELOCATION. | | | PROVIDE AN ARBORIST REPORT SHOWING CONDITION AND | | | RELOCATION POTENTIAL FOR ANY NATIVE TREES OR PALMS | | | TREES AND PALMS PROPOSED TO BE REMOVED. APPLICANT HAS | | | INDICATED A TREE DISPOSITION LIST WILL BE PROVIDED WITH | | | THE RESUBMITTAL. | | | | | | 2. THE SITE PLAN AND LANDSCAPE PLAN DO NOT MATCH THE | | | SURVEY ALONG THE EAST PROPERTY LINE. THE PERVIOUS AREA | | | IS OUTSIDE THE FENCE ON THE ADJACENT PROPERTY. CORRECT | | | THE PLANS TO MATCH THE SURVEY. IF PERVIOUS AREA IS | | | BEING ADDED, INDICATE THIS ON THE SITE PLAN AND PROVIDE | | | THE REQUIRED LANDSCAPE BUFFER ALONG THE EAST PROPERTY | | | LINE. | | | | | | 3. PER SECTION 94-443(C)(3)A. AND B., TERMINAL | | | LANDSCAPE ISLANDS AND INTERIOR ISLANDS MUST HAVE AT | | | LEAST 8 FEET WIDE LANDSCAPE AREA AND RUN THE FULL | | | LENGTH OF THE ADJACENT PARKING SPACE. EACH AREA SHALL | | | HAVE AT LEAST ONE SHADE OR FLOWERING TREE PER ROW OF | | | PARKING AND AN INTERIOR ISLAND MUST BE PROVIDED SO | | | THERE ARE NO MORE THAN 10 SPACES IN A ROW. PROVIDE THE | | | REQUIRED LANDSCAPE ISLANDS FOR ALL REQUIRED PARKING. | | | THERE ARE TERMINAL ISLANDS MISSING IN SEVERAL | | | LOCATIONS. | | | | | | 4. SECTION 94-443(C)(3) REQUIRES THAT A MINIMUM OF 75 | | | PERCENT OF ALL TREES THAT ARE REQUIRED TO BE PLANTED | | | WITHIN THE INTERIOR OF AN OFF STREET PARKING AREA SHALL | | | BE CATEGORY 1 SHADE TREES. HIGH RISE OAK DOES NOT MEET | | | THE INTENT OF PROVIDING TREE CANOPY FOR THE PARKING | | | AREAS SO CANNOT BE COUNTED. | | | | | | 5. PROVIDE AN EXHIBIT SHOWING THE PARKING AREA | | | VEHICULAR USE AREA SURFACE CALCULATIONS, PARKING SPACE | | | AREAS AND LANDSCAPE AREAS PROVIDED TO DEMONSTRATE | | | COMPLIANCE WITH SECTIONS 94-443 (C)(3) AND (4). PROVIDE | | | THE CORRECTED CALCULATIONS IN THE LANDSCAPE REQUIREMENT | | | CHART. REFER TO FIGURE XIV-1. SHOW THE ACTUAL PROVIDED | | | INTERIOR LANDSCAPE SQUARE FOOTAGE. BUFFERS AND | | | NON-INTERIOR LANDSCAPING CANNOT BE COUNTED. | | | | | | 6. STORMWATER LINE AND EXFILTRATION PROPOSED ALONG THE | | | EAST SIDE OF THE PARKING AREA CONFLICT WITH THE | | | REQUIRED LANDSCAPE TERMINAL ISLAND AND TREE | | | REQUIREMENT. ADJUST THE DRAINAGE LINE TO AVOID THE | | | REQUIRED LANDSCAPING. | | | | | | 7. PROVIDE A DIAGRAM OF THE 30% REQUIRED AND PROVIDED | | | LINEAR LANDSCAPE FOR AROUND EACH BUILDING INCLUDING THE | | | CAR WASH BUILDING AS INDICATED IN THE CODE REQUIREMENT | | | CHART. THE CODE REQUIRES TREES SHRUBS OR HEDGES. | | | | | | 8. IMPERVIOUS/LANDSCAPE AREA IS NOT WITHIN THE | | | REQUIREMENT OF 15% OF THE SITE. STAFF SUGGESTS ADDING | | | LANDSCAPE AREA TO MEET THE 15% REQUIRED. THERE ARE MANY | | | OPPORTUNITIES THAT CAN BE IMPROVED IN THE STORAGE AREAS | | | | | | 9. UTILITY LINES ARE SHOWN, BUT THERE ARE MULTIPLE | | | CONFLICTS WITH THE LOCATIONS OF LINES AND LANDSCAPING. | | | ADJUST LOCATIONS OF UTILITIES TO AVOID LANDSCAPE AREAS. | | | | | | 10. MINIMUM NUMBER OF REQUIRED TREES IS NOT MET FOR THE | | | SITE. ADD TREES TO MEET THE MINIMUM REQUIRED. UP TO 35% | | | OF THE REQUIRED TREES CAN BE PALM SUBSTITUTIONS. | | | | | | 11. PROVIDE THE 50 REQUIRED FLORIDA FRIENDLY POINTS | | | BASED ON THE FINAL PLANT LIST PER SECTION 94-443(G) | | | AFTER REVISIONS TO PLANS ARE MADE. | | | | | | CONDITIONS OF APPROVAL | | | 1. PRIOR TO THE REMOVAL OR RELOCATION OF ANY TREES ON | | | THE PROPERTY, A TREE ALTERATION PERMIT SHALL BE | | | SUBMITTED, REVIEWED AND APPROVED BY THE DEVELOPMENT | | | SERVICES DEPARTMENT, PLANNING DIVISION. | | | | | | |
|
|
| Review Stop |
PARK |
PARKING |
| Rev No |
1 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
|
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
POLICE |
POLICE |
| Rev No |
1 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
|
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
PU |
PUBLIC UTILITIES |
| Rev No |
2 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
PU |
PUBLIC UTILITIES |
| Rev No |
1 |
Status |
P |
Date |
10-13-2022 |
|
|
Cont ID |
|
| Sent By |
mtechnow |
Date |
10-13-2022 |
Time |
11:46 |
Rev Time |
0.00 |
| Received By |
mtechnow |
Date |
10-13-2022 |
Time |
11:46 |
Sent To |
|
|
| Notes |
| 2022-10-13 11:46:27 | -ADD NOTE THAT THIS IS WITHIN LS 50 SERVICE AREA. | | | -PLANS APPROVED. |
|
|
| Review Stop |
PU-CS |
PUBLIC UTILITIES CUSTOMER SRVC |
| Rev No |
2 |
Status |
P |
Date |
01-05-2023 |
|
|
Cont ID |
|
| Sent By |
mhurley |
Date |
01-05-2023 |
Time |
07:05 |
Rev Time |
0.00 |
| Received By |
mhurley |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
PU-CS |
PUBLIC UTILITIES CUSTOMER SRVC |
| Rev No |
1 |
Status |
P |
Date |
10-11-2022 |
|
|
Cont ID |
|
| Sent By |
mhurley |
Date |
10-11-2022 |
Time |
07:42 |
Rev Time |
0.00 |
| Received By |
mhurley |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
PW |
PUBLIC WORKS |
| Rev No |
2 |
Status |
P |
Date |
01-05-2023 |
|
|
Cont ID |
|
| Sent By |
|
Date |
01-05-2023 |
Time |
|
Rev Time |
0.00 |
| Received By |
|
Date |
01-05-2023 |
Time |
|
Sent To |
|
|
| Notes |
| 2023-01-05 12:06:12 | CONDITION OF APPROVAL: | | | | | | FOR A FREESTANDING SITE DUMPSTER ENCLOSURE, THE | | | ENCLOSURE SHALL COMPLY WITH THE LATEST REVISION OF CITY | | | OF WEST PALM BEACH GENERAL CONSTRUCTION-GARBAGE | | | ENCLOSURE STANDARD, GC-7. (LINK TO THE LATEST REVISION | | | OF THE GC-7 DOCUMENT: HTTPS://WWW.WPB.ORG/HOME/SHOWPUBL | | | ISHEDDOCUMENT/3690/637629060422100000 | | | | | | MATT HEJAZI | | | DEPT. OF PUBLIC WORKS | | | [email protected] | | | 561-822-2045 |
|
|
| Review Stop |
PW |
PUBLIC WORKS |
| Rev No |
1 |
Status |
F |
Date |
10-06-2022 |
|
|
Cont ID |
|
| Sent By |
|
Date |
10-06-2022 |
Time |
|
Rev Time |
|
| Received By |
|
Date |
10-06-2022 |
Time |
|
Sent To |
|
|
| Notes |
| 2022-10-06 10:16:46 | PLEASE PROVIDE THE FOLLOWINGS: | | | 1- LOS (LEVEL OF SERVICE ANALYSIS) TO REFLECT THE SOLID | | | WASTE VOLUME PRODUCED ALONG WITH THE SIZE, TYPE AND | | | QUANTITY OF THE CONTAINER (I.E. DUMPSTER/COMPACTOR) | | | THAT WILL BE UTILIZED FOR THE SANITATION SERVICE. | | | 2- DUMPSTER ENCLOSURE DETAIL. FOR A FREESTANDING SITE | | | DUMPSTER ENCLOSURE, THE ENCLOSURE SHALL COMPLY WITH THE | | | LATEST REVISION OF CITY OF WEST PALM BEACH GENERAL | | | CONSTRUCTION-GARBAGE ENCLOSURE STANDARD, GC-7. (LINK TO | | | THE LATEST REVISION OF THE GC-7 DOCUMENT: HTTPS://WWW.W | | | PB.ORG/HOME/SHOWPUBLISHEDDOCUMENT/3690/6376290604221000 | | | 00) | | | 3- AUTOTURN EXHIBIT WITH DYNAMIC ENVELOPE AND THE | | | VEHICLE???S WHEEL PATH IDENTIFIED WITH DIFFERENT COLORS | | | FOR THE SANITATION SERVICE, FRONT LOADER TRUCK WITH THE | | | FOLLOWING SPECS: | | | - DUAL AXLES | | | - TRUCK LENGTH: 35 FT | | | - TRUCK WIDTH: 11 FT | | | - TURNING RADIUS: | | | - SAE TURNING RADIUS: 32.5 FT | | | - CURB-TO-CURB DIAMETER: 74 FT | | | - WALL-TO-WALL DIAMETER: 86.3 FT | | | 4- IN CASE OF PROPOSING ADDITION OF ANY NEW CAN(S) IN | | | THE CITY`S RIGHT-OF-WAY , THE LOCATION AND QUANTITY OF | | | THE CAN(S) SHALL BE REVIEWED AND APPROVED BY PUBLIC | | | WORKS DEPARTMENT AND THE CAN(S) SHALL BE TYPE, SIZE AND | | | COLOR APPROVED BY PUBLIC WORKS DEPARTMENT. THE BUILDING | | | MAINTENANCE IS RESPONSIBLE TO MAINTAIN AND SERVICE THE | | | CAN(S). | | | 5- ALL THE PARKING STALL PAINTING SHALL COMPLY WITH THE | | | CITY`S MUNICIPAL CODE SECTION 94-485 AND FLORIDA | | | STATUES [553.5041 F.S.]. | | | 6- SIGNAGE PLAN. ALL STRIPING AND SIGNAGE SHALL COMPLY | | | WITH THE LATEST CITY OF WEST PALM BEACH STANDARD | | | DETAILS AND MEET THE M.U.T.C.D. LATEST EDITION. | | | 7- ALL PAVEMENT MARKING , SIGNING AND SIDEWALK DAMAGED | | | DURING CONSTRUCTION SHALL BE RESTORED. | | | | | | | | | MATT HEJAZI | | | DEPT. OF PUBLIC WORKS | | | [email protected] | | | 561-822-2045 |
|
|
| Review Stop |
STORM |
STORMWATER |
| Rev No |
3 |
Status |
P |
Date |
02-22-2023 |
|
|
Cont ID |
|
| Sent By |
tward |
Date |
02-22-2023 |
Time |
11:16 |
Rev Time |
0.00 |
| Received By |
tward |
Date |
02-22-2023 |
Time |
11:17 |
Sent To |
|
|
| Notes |
| 2023-02-22 11:16:51 | THE FOLLOWING COMMENTS ARE FROM THE REVIEW OF THE | | | 2/8/2023 SUBMITTAL. PREVIOUSLY SATISFIED COMMENTS ARE | | | REMOVED. REMAINING OPEN AND NEW COMMENTS CAN BE | | | ADDRESSED WITH THE ENGINEERING PERMIT SUBMITTAL. | | | | | | 1. [PARTIALLY SATISFIED - SHEET 2 OF THE CONCEPTUAL | | | ENGINEERING PLANS LIST NAVD1988 AT THE BOTTOM RIGHT OF | | | THE PAGE.] BE CONSISTENT WITH THE VERTICAL DATUM USED | | | ON THE SURVEY AND ON THE ENGINEERING PLANS. THE CITY'S | | | OFFICIAL VERTICAL DATUM PER CITY CODE IS NGVD1929. THE | | | NAVD1988 VERTICAL DATUM MAY BE USED IF THE CONVERSION | | | EQUATION BETWEEN NAVD1988 AND NGVD1929 IS PROVIDED. | | | LIST THE VERTICAL DATUM AND CONVERSION EQUATION (IF | | | APPLICABLE) ON EVERY SHEET WITH ELEVATION INFORMATION. | | | | | | NEW COMMENTS (1/4/2023 SUBMITTAL): | | | | | | 4. [SATISFIED] UTILITIES SHOWN ON THE LANDSCAPE PLANS | | | DO NOT MATCH THE CONCEPTUAL ENGINEERING PLANS. | | | | | | 5. [SATISFIED] GRATE ELEVATION (19.00 FT NGVD) OF THE | | | CONTROL STRUCTURE IS HIGHER THAN THE PERIMETER | | | ELEVATION (18.75 FT NGVD) SHOWN IN THE TYPICAL DRY | | | RETENTION AREA / PERIMETER BERM SECTION DETAIL ON SHEET | | | 1. CONSIDER MOVING THE CONTROL STRUCTURE TO THE WEST | | | INTO THE INTERIOR OF THE DRY RETENTION AREA, | | | ELIMINATING THE WEIR AND THE WEST PIPE AND STRUCTURE TO | | | THE WEST AND LOWERING THE GRATE ELEVATION TO CONTROL | | | ELEVATION OF 18.35. A SKIMMER COULD BE ATTACHED TO THE | | | OUTSIDE OF THE STRUCTURE AND/OR A PRB PLACED OVER THE | | | EAST PIPE. | | | | | | 6. [SATISFIED] PROVIDE CROSS SECTIONS THROUGH THE NEW | | | PARKING LOTS SHOWING SURFACE FEATURES, DIMENSIONS, | | | SLOPES (ARROWS) AND GRADE BREAKS. | | | | | | 7. [SATISFIED] CONVERT THE SURFACE WATER MANAGEMENT | | | SUMMARY INFORMATION ON SHEET 1 TO THE DATUM USED ON THE | | | PLANS. | | | | | | NEW COMMENTS (2/8/2023 SUBMITTAL): | | | 8. INDICATE LOCATION OF WHEEL STOPS ON SECTION A-A ON | | | SHEET 1. | | | | | | 9. CHECK THE GRADES VS. THE TRAVEL LANE SLOPES AND | | | WIDTHS SHOWN ON SECTION A-A ON SHEET 1. | | | | | | 10. CONFIRM FINISHED FLOOR ELEVATION OF 19.50 FT NGVD | | | SHOWN ON THE BUILDING PAD AND IN THE SURFACE WATER | | | MANAGEMENT SUMMARY AT THE TOP OF SHEET 1. | | | | | | 11. RECTIFY THE TWO TOP OF PLATE ELEVATIONS (16.00 / | | | 18.35) ON THE CONTROL STRUCTURE DETAIL (STRUCTURE S-3) | | | ON SHEET 2. | | | | | | TRACY WARD, PE | | | SENIOR STORMWATER ENGINEER | | | ENGINEERING SERVICES DEPARTMENT | | | 561-494-1120 (O) | | | [email protected] | | | |
|
|
| Review Stop |
STORM |
STORMWATER |
| Rev No |
2 |
Status |
F |
Date |
01-20-2023 |
|
|
Cont ID |
|
| Sent By |
tward |
Date |
01-20-2023 |
Time |
08:56 |
Rev Time |
0.00 |
| Received By |
tward |
Date |
01-20-2023 |
Time |
08:58 |
Sent To |
|
|
| Notes |
| 2023-01-20 08:58:19 | THE FOLLOWING COMMENTS ARE FROM THE REVIEW OF THE | | | 1/4/2023 SUBMITTAL: | | | 1. [PARTIALLY SATISFIED ??? SHEET 2 OF THE CONCEPTUAL | | | ENGINEERING PLANS LIST NAVD1988] BE CONSISTENT WITH THE | | | VERTICAL DATUM USED ON THE SURVEY AND ON THE | | | ENGINEERING PLANS. THE CITY???S OFFICIAL VERTICAL DATUM | | | PER CITY CODE IS NGVD1929. THE NAVD1988 VERTICAL DATUM | | | MAY BE USED IF THE CONVERSION EQUATION BETWEEN NAVD1988 | | | ABD NGVD1929 IS PROVIDED. LIST THE VERTICAL DATUM AND | | | CONVERSION EQUATION (IF APPLICABLE) ON EVERY SHEET WITH | | | ELEVATION INFORMATION. | | | | | | 2. [SATISFIED] PROVIDE A DETAIL OF THE CONTROL | | | STRUCTURE. | | | | | | 3. [SATISFIED ??? NOTE CITY STANDARD PARKING SPACE | | | DIMENSIONS ARE 8.5 FT X 18 FT FOR STANDARD PARKING | | | SPACES. SITE PLAN SHOWS STANDARD PARKING SPACE | | | DIMENSION AS 10 FT X 20 FT] CONSIDER PROVIDING 2 FEET | | | OF OVERHANG FOR THE EAST PARKING SPACES. SHOW AND LABEL | | | THE PARKING OVERHANG. | | | | | | NEW COMMENTS (1/4/2023 SUBMITTAL) | | | | | | 4. UTILITIES SHOWN ON THE LANDSCAPE PLANS DO NOT MATCH | | | THE CONCEPTUAL ENGINEERING PLANS. | | | | | | 5. GRATE ELEVATION (19.00 FT NGVD) OF THE CONTROL | | | STRUCTURE IS HIGHER THAN THE PERIMETER ELEVATION (18.75 | | | FT NGVD) SHOWN IN THE ???TYPICAL DRY RETENTION AREA / | | | PERIMETER BERM SECTION??? DETAIL ON SHEET 1. CONSIDER | | | MOVING THE CONTROL STRUCTURE TO THE WEST INTO THE | | | INTERIOR OF THE DRY RETENTION AREA, ELIMINATING THE | | | WEIR AND THE WEST PIPE AND STRUCTURE TO THE WEST AND | | | LOWERING THE GRATE ELEVATION TO CONTROL ELEVATION OF | | | 18.35. A SKIMMER COULD BE ATTACHED TO THE OUTSIDE OF | | | THE STRUCTURE AND/OR A PRB PLACED OVER THE EAST PIPE. | | | | | | 6. PROVIDE CROSS SECTIONS THROUGH THE NEW PARKING LOTS | | | SHOWING SURFACE FEATURES, DIMENSIONS, SLOPES (ARROWS) | | | AND GRADE BREAKS. | | | | | | 7. CONVERT THE SURFACE WATER MANAGEMENT SUMMARY | | | INFORMATION ON SHEET 1 TO THE DATUM USED ON THE PLANS. | | | | | | TRACY WARD, PE | | | SENIOR STORMWATER ENGINEER | | | ENGINEERING SERVICES DEPARTMENT | | | 561-494-1120 (O) | | | [email protected] | | | |
|
|
| Review Stop |
STORM |
STORMWATER |
| Rev No |
1 |
Status |
F |
Date |
10-13-2022 |
|
|
Cont ID |
|
| Sent By |
tward |
Date |
10-13-2022 |
Time |
00:03 |
Rev Time |
0.00 |
| Received By |
tward |
Date |
10-13-2022 |
Time |
00:04 |
Sent To |
|
|
| Notes |
| 2022-10-13 00:04:11 | THIS IS A CONCEPTUAL LEVEL REVIEW. CONSTRUCTION LEVEL | | | DETAILS, DESIGN CALCULATIONS AND THE POLLUTION | | | PREVENTION PLAN WILL BE REVIEWED AS PART OF THE | | | ENGINEERING DEVELOPMENT APPROVAL AND BUILDING PERMIT | | | APPLICATION PROCESSES. | | | | | | THE FOLLOWING COMMENTS MUST BE ADDRESSED PRIOR TO SITE | | | PLAN APPROVAL: | | | | | | 1. BE CONSISTENT WITH THE VERTICAL DATUM USED ON THE | | | SURVEY AND ON THE ENGINEERING PLANS. THE CITY???S | | | OFFICIAL VERTICAL DATUM PER CITY CODE IS NGVD1929. THE | | | NAVD1988 VERTICAL DATUM MAY BE USED IF THE CONVERSION | | | EQUATION BETWEEN NAVD1988 ABD NGVD1929 IS PROVIDED. | | | LIST THE VERTICAL DATUM AND CONVERSION EQUATION (IF | | | APPLICABLE) ON EVERY SHEET WITH ELEVATION INFORMATION. | | | | | | 2. PROVIDE A DETAIL OF THE CONTROL STRUCTURE. | | | | | | 3. CONSIDER PROVIDING 2 FEET OF OVERHANG FOR THE EAST | | | PARKING SPACES. SHOW AND LABEL THE PARKING OVERHANG. | | | | | | | | | THE FOLLOWING COMMENTS MUST BE ADDRESSED PRIOR TO | | | ISSUANCE OF CONSTRUCTION AUTHORIZATION INCLUDING | | | BUILDING PERMITS AND ENGINEERING DEVELOPMENT APPROVAL. | | | | | | 1. DRAINAGE SYSTEM TO BE DESIGNED TO MEET SFWMD ERP | | | CRITERIA. STORMWATER CALCULATIONS WILL BE REVIEWED WITH | | | THE ENGINEERING PERMIT SUBMITTAL. | | | | | | 2. PROVIDE COPY OF SFWMD ERP PERMIT BEFORE START OF | | | CONSTRUCTION. | | | | | | 3. PROVIDE EROSION AND SEDIMENT CONTROL PLAN WITH THE | | | ENGINEERING PERMIT SUBMITTAL. | | | | | | | | | TRACY WARD, PE | | | SENIOR STORMWATER ENGINEER | | | ENGINEERING SERVICES DEPARTMENT | | | 561-494-1120 (O) | | | [email protected] | | | |
|
|
| Review Stop |
SURVEY |
SURVEYING |
| Rev No |
2 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SURVEY |
SURVEYING |
| Rev No |
1 |
Status |
P |
Date |
10-11-2022 |
|
|
Cont ID |
|
| Sent By |
vnoel |
Date |
10-11-2022 |
Time |
13:00 |
Rev Time |
|
| Received By |
vnoel |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2022-10-11 13:09:36 | 1. PROPERTY LIES WITHIN RIVIERA BEACH'S WATER AND SEWER | | | SERVICE AREA. |
|
|
| Review Stop |
TRAFFIC |
TRAFFIC ENGINEERING |
| Rev No |
3 |
Status |
P |
Date |
02-17-2023 |
|
|
Cont ID |
|
| Sent By |
|
Date |
02-17-2023 |
Time |
|
Rev Time |
0.00 |
| Received By |
|
Date |
02-17-2023 |
Time |
|
Sent To |
|
|
| Notes |
| 2023-02-17 10:50:56 | NO FURTHER COMMENTS. | | | | | | PREVIOUS COMMENTS: | | | 1) SATISFIED. PROVIDE AUTOTURN ANALYSIS FOR GARBAGE | | | TRUCK AND/OR SERVICE VEHICLES DRIVING IN AND OUT OF THE | | | PROPOSED DEVELOPMENT WITH VEHICLE DYNAMIC ENVELOPES AND | | | WHEEL PATHS CLEARLY DISTINCT AND DEFINED IN DIFFERENT | | | COLORS | | | 2) SATISFIED. PROVIDE A PARKING TABLE SHOWCASING THE | | | NUMBER OF REQUIRED AND PROVIDED PARKING SPACES, | | | INCLUSIVE OF ADA AND BICYCLE ONES | | | 3) SATISFIED. SHOWCASE DRIVEWAYS??? WIDTH | | | 4) SATISFIED. INSTALL PEDESTRIAN CROSSWALKS TO CONNECT | | | THE SIDEWALK NORTH AND SOUTH OF THE PROPOSED | | | SOUTH-EASTERN PARKING LOT | | | 5) SATISFIED. INSTALL A PEDESTRIAN CROSSWALK ACROSS | | | PARKE AVE BY THE STOP LOCATION SOUTH OF THE EXISTING | | | DRIVEWAY | | | 6) SATISFIED. INSTALL WHEEL STOPS AT EACH PARKING | | | STALLS ABUTTING A PEDESTRIAN WALKWAY | | | 7) SATISFIED. INSTALL STOP BAR AND SIGNAGE AT THE | | | PROPOSED NORTHERN DRIVEWAY OUTBOUND LANE | | | | | | VALERIO ORICCHIO | | | CITY TRANSPORTATION ENGINEER | | | 561-494-1092 | | | [email protected] | | | |
|
|
| Review Stop |
TRAFFIC |
TRAFFIC ENGINEERING |
| Rev No |
2 |
Status |
F |
Date |
01-19-2023 |
|
|
Cont ID |
|
| Sent By |
|
Date |
01-19-2023 |
Time |
|
Rev Time |
0.00 |
| Received By |
|
Date |
01-19-2023 |
Time |
|
Sent To |
|
|
| Notes |
| 2023-01-19 21:27:15 | 1) SATISFIED. PROVIDE AUTOTURN ANALYSIS FOR GARBAGE | | | TRUCK AND/OR SERVICE VEHICLES DRIVING IN AND OUT OF THE | | | PROPOSED DEVELOPMENT WITH VEHICLE DYNAMIC ENVELOPES AND | | | WHEEL PATHS CLEARLY DISTINCT AND DEFINED IN DIFFERENT | | | COLORS | | | 2) NOT SATISFIED. PROVIDE A PARKING TABLE SHOWCASING | | | THE NUMBER OF REQUIRED AND PROVIDED PARKING SPACES, | | | INCLUSIVE OF ADA AND BICYCLE ONES | | | 3) NOT SATISFIED. SHOWCASE DRIVEWAYS??? WIDTH | | | 4) NOT SATISFIED. INSTALL PEDESTRIAN CROSSWALKS TO | | | CONNECT THE SIDEWALK NORTH AND SOUTH OF THE PROPOSED | | | SOUTH-EASTERN PARKING LOT | | | 5) NOT SATISFIED. INSTALL A PEDESTRIAN CROSSWALK ACROSS | | | PARKE AVE BY THE STOP LOCATION SOUTH OF THE EXISTING | | | DRIVEWAY | | | 6) NOT SATISFIED. INSTALL WHEEL STOPS AT EACH PARKING | | | STALLS ABUTTING A PEDESTRIAN WALKWAY | | | 7) NOT SATISFIED. INSTALL STOP BAR AND SIGNAGE AT THE | | | PROPOSED NORTHERN DRIVEWAY OUTBOUND LANE | | | | | | VALERIO ORICCHIO | | | CITY TRANSPORTATION ENGINEER | | | 561-494-1092 | | | [email protected] | | | |
|
|
| Review Stop |
TRAFFIC |
TRAFFIC ENGINEERING |
| Rev No |
1 |
Status |
F |
Date |
10-13-2022 |
|
|
Cont ID |
|
| Sent By |
|
Date |
10-13-2022 |
Time |
|
Rev Time |
|
| Received By |
|
Date |
10-13-2022 |
Time |
|
Sent To |
|
|
| Notes |
| 2022-10-13 07:09:41 | 1) PROVIDE AUTOTURN ANALYSIS FOR GARBAGE TRUCK AND/OR | | | SERVICE VEHICLES DRIVING IN AND OUT OF THE PROPOSED | | | DEVELOPMENT WITH VEHICLE DYNAMIC ENVELOPES AND WHEEL | | | PATHS CLEARLY DISTINCT AND DEFINED IN DIFFERENT COLORS | | | 2) PROVIDE A PARKING TABLE SHOWCASING THE NUMBER OF | | | REQUIRED AND PROVIDED PARKING SPACES, INCLUSIVE OF ADA | | | AND BICYCLE ONES | | | 3) SHOWCASE DRIVEWAYS??? WIDTH | | | 4) INSTALL PEDESTRIAN CROSSWALKS TO CONNECT THE | | | SIDEWALK NORTH AND SOUTH OF THE PROPOSED SOUTH-EASTERN | | | PARKING LOT | | | 5) INSTALL A PEDESTRIAN CROSSWALK ACROSS PARKE AVE BY | | | THE STOP LOCATION SOUTH OF THE EXISTING DRIVEWAY | | | 6) INSTALL WHEEL STOPS AT EACH PARKING STALLS ABUTTING | | | A PEDESTRIAN WALKWAY | | | 7) INSTALL STOP BAR AND SIGNAGE AT THE PROPOSED | | | NORTHERN DRIVEWAY OUTBOUND LANE | | | | | | VALERIO ORICCHIO | | | CITY TRANSPORTATION ENGINEER | | | 561-494-1092 | | | [email protected] | | | | | 2022-10-13 06:24:45 | 1) PROVIDE AUTOTURN ANALYSIS FOR GARBAGE TRUCK AND/OR | | | SERVICE VEHICLES DRIVING IN AND OUT OF THE PROPOSED | | | DEVELOPMENT WITH VEHICLE DYNAMIC ENVELOPES AND WHEEL | | | PATHS CLEARLY DISTINCT AND DEFINED IN DIFFERENT COLORS | | | 2) PROVIDE A PARKING TABLE SHOWCASING THE NUMBER OF | | | REQUIRED AND PROVIDED PARKING SPACES, INCLUSIVE OF ADA | | | AND BICYCLE ONES | | | 3) SHOWCASE DRIVEWAYS' WIDTH | | | 4) INSTALL PEDESTRIAN CROSSWALKS TO CONNECT THE | | | SIDEWALK NORTH AND SOUTH OF THE PROPOSED SOUTH-EASTERN | | | PARKING LOT | | | 5) INSTALL A PEDESTRIAN CROSSWALK ACROSS PARKE AVE BY | | | THE STOP LOCATION SOUTH OF THE EXISTING DRIVEWAY | | | 6) INSTALL WHEEL STOPS AT EACH PARKING STALLS ABUTTING | | | A PEDESTRIAN WALKWAY | | | 7) INSTALL STOP BAR AND SIGNAGE AT THE PROPOSED | | | NORTHERN DRIVEWAY OUTBOUND LANE | | | 8) CONSIDER INSTALLING A FEW STANDARD (22-FEET LONG) | | | PARKING STALLS | | | | | | VALERIO ORICCHIO | | | CITY TRANSPORTATION ENGINEER | | | 561-494-1092 | | | [email protected] | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
02-16-2023 |
|
|
Cont ID |
|
| Sent By |
vbroglia |
Date |
02-16-2023 |
Time |
14:47 |
Rev Time |
0.00 |
| Received By |
vbroglia |
Date |
02-16-2023 |
Time |
14:47 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
01-17-2023 |
|
|
Cont ID |
|
| Sent By |
vbroglia |
Date |
01-17-2023 |
Time |
14:06 |
Rev Time |
0.00 |
| Received By |
vbroglia |
Date |
01-17-2023 |
Time |
14:06 |
Sent To |
|
|
| Notes |
| 2023-01-17 14:07:08 | CASE NO. 22-10 (Z22090021) | | | PROJECT NAME: GRAMERCY PARK- 2ND RESUBMITTAL | | | LOCATION: 5615 PARKER AVE | | | | | | CONTACT: VALENTINA BROGLIA, PLANNER AT (561) 822-1442 | | | OR [email protected] | | | | | | 1. PLEASE NOTE THE SITE PLAN PROPOSES 29 PARKING | | | SPACES, AND PARKING TABLE NOTES THERE ARE 33 PROPOSED | | | PARKING SPACES. NOTE: 23 PARKING SPACES ARE REQUIRED, | | | AND 2 ADA PARKING SPACES ARE REQUIRED (AS PROVIDED) FOR | | | THE 29 PROPOSED PARKING SPACES. | | | 2. DUMPSTER ENCLOSURE WILL REQUIRE WALLS TO BE | | | LANDSCAPED WITH HEDGE AND SHRUBS AT 2 FEET INTERVALS, | | | PER SECTION 94-315(A) | | | 3. PLEASE NOTE FOR MANMADE RETENTION | | | LAKES/PONDS/STRUCTURES IN A CON ZONING DISTRICT IS | | | PERMITTED WITH EXTRA REQUIREMENTS PER STATED IN THE | | | ZONING CODE SECTION 94-273(E)(41): | | | 1. PROOF OF SUCH PERMITS AS ARE REQUIRED BY LOCAL, | | | STATE, OR ANY OTHER APPLICABLE AUTHORITIES. | | | 2. A 20-FOOT WIDE MAINTENANCE EASEMENT SHALL BE THE | | | PERIMETER OF ALL ARTIFICIAL LAKES AND PONDS. THE | | | EASEMENT SHALL HAVE A MAXIMUM SLOPE OF ONE FOOT | | | VERTICAL FOR EACH EIGHT FEET HORIZONTAL. THE WIDTH OF | | | THE EASEMENT SHALL BE MEASURED FROM THE HIGH WATER | | | ELEVATION OF THE LAKE OR POND. | | | 3. THE MAXIMUM SLOPE OF SUBAQUEOUS AREAS SHALL BE 1:4 | | | FROM THE HIGH WATER ELEVATION TO A DEPTH OF TWO FEET | | | BELOW THE LOW WATER ELEVATION. THE MAXIMUM SLOPE OF | | | SUBAQUEOUS AREAS SHALL BE 1:2 BELOW A DEPTH OF TWO FEET | | | BELOW THE LOW WATER ELEVATION. | | | | | | WHEN RESUBMITTING, PLEASE PROVIDE A MINIMUM OF THREE | | | (3) PAPER COPIES AND DIGITAL PLANS IN .PNG/.PDF FORMAT | | | OF ALL THE PLANS. PLEASE NOTE THAT CHANGES ON THE | | | RESUBMITTED PLANS OR THE SUBMITTAL OF INFORMATION/PLANS | | | TO ADDRESS THE COMMENTS MAY RESULT IN ADDITIONAL | | | COMMENTS. | | | | | | -PLEASE NOTE THAT IS THE PLANNING DIVISION HAS NOT | | | RECEIVED A RESPONSE TO THE PPRC COMMENTS/REVIEW COMMENT | | | WITHIN 60 DAYS FROM THE DATE OF THE PPRC | | | MEETING/COMMENT ISSUANCE (BY **), THE PLANNING DIVISION | | | MAY NOTIFY THE APPLICANT THAT THE CASE IS CONSIDERED | | | WITHDRAWN. ANY FURTHER ACTION WILL REQUIRE A NEW | | | DEVELOPMENT APPLICATION. | | | | | | -PLEASE NOTE THAT YOU WILL BE PERMITTED ONE (1) | | | RESUBMITTAL AT NO ADDITIONAL COST. IF PREVIOUSLY ISSUED | | | COMMENTS CONTINUE TO NOT BE SUFFICIENTLY ADDRESSED, THE | | | APPLICANT WILL BE ASSESSED A RESUBMITTAL FEE, SUCH FEE | | | WILL BE 20% OF THE ORIGINAL APPLICATION FEE | | | | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
10-11-2022 |
|
|
Cont ID |
|
| Sent By |
afowlkes |
Date |
10-11-2022 |
Time |
11:17 |
Rev Time |
0.00 |
| Received By |
afowlkes |
Date |
10-11-2022 |
Time |
11:17 |
Sent To |
|
|
| Notes |
| 2022-10-11 11:18:47 | CASE NO. Z22090021 | | | CASE NAME GRAMERCY PARK | | | ADDRESS 5615 PARKE AVENUE | | | | | | - CONTACT ALEXANDER FOWLKES @ (561) 822-1446, | | | [email protected] | | | | | | - PLEASE PROVIDE RESPONSES TO REVIEW COMMENTS IN | | | WRITTEN FORMAT. | | | | | | 1. IT SEEMS THAT YOU HAVE ANALYZED THE ENTIRE SUBJECT | | | AREA AS ONE PARCEL WITH AN ROS ZONING, WHEN IN FACT | | | THIS IS 2 SEPARATE PARCELS. THE SOUTHERNMOST PARCEL IS | | | ZONED ROS, HOWEVER THE NORTHERNMOST PARCEL IS ZONED | | | CON. THESE ZONING CLASSIFICATIONS HAVE DIFFERENT | | | REQUIREMENTS AND MUST BE ANALYZED AS SUCH. PLEASE | | | PROVIDE SEPARATE SITE CALCULATION TABLES TO SHOW | | | COMPLIANCE WITH SEC. 94-204 FOR THE ROS PARCEL AND SEC. | | | 94-205 FOR THE CON PARCEL. | | | 2. PLEASE PROVIDE MORE INFORMATION ON THE FUTURE PLANS | | | FOR THIS PARK. PRIOR TO YOUR SUBMITTAL, IT WAS | | | STAFF???S UNDERSTANDING THAT YOU WERE COMING IN ONLY TO | | | SEEK APPROVAL FOR A MULCH PATH GOING INTO THE CON | | | PARCEL AND THE COMMUNITY CENTER AND ACCOMPANYING SITE | | | IMPROVEMENTS FOR THE ROS PARCEL. YET WE ARE SEEING SOME | | | LARGE RETENTION PONDS GOING INTO THE CON PARCEL, | | | RESULTING IN THE DISPOSITION OF A SIGNIFICANT NUMBER OF | | | TREES. IS THIS PART OF A LATER PHASE OF DEVELOPMENT OR | | | ARE YOU SEEKING APPROVAL FOR THESE AS A PART OF THIS | | | APPLICATION? | | | 2A. PLEASE NOTE THAT ONLY PASSIVE USES ARE PERMITTED | | | WITHIN PARKS IN CON ZONING DESIGNATIONS. | | | 2B. PLEASE NOTE THAT REMOVING SUCH A SIGNIFICANT NUMBER | | | OF TREES FOR WATER RETENTION PONDS IN A CON ZONED | | | PARCEL WOULD NOT BE PERMITTED. YOU WILL NEED TO GO | | | THROUGH A REZONING AND FUTURE LAND USE AMENDMENT TO | | | PERMIT SUCH DEVELOPMENT. SO, IF THIS IS PART OF A | | | FUTURE PHASE PLEASE DENOTE IT AS SUCH SO WE CAN MOVE | | | FORWARD WITH THIS APPLICATION. | | | 3. PLEASE PROVIDE MORE INFORMATION ON THE BACKGROUND OF | | | THE CON PARCEL. STAFF IS UNSURE WHY THIS PARCEL IS | | | ZONED FOR CONSERVATION AND WOULD LIKE MORE INFORMATION | | | REGARDING WHAT IS BEING PRESERVED OR PROTECTED HERE. | | | 3A. IF YOU ARE PROPOSING DEVELOPMENT THAT WOULD GO | | | BEYOND PASSIVE USES WITHIN THE CON PARCEL, AN | | | ENVIRONMENTAL ASSESSMENT WILL BE REQUIRED SHOWING THERE | | | ARE NO THREATENED, ENDANGERED, OR RARE SPECIES. | | | 4. YOU HAVE PROPOSED 4 PARKING SPACES IN THE CON | | | PARCEL. ALTHOUGH CON ZONED AREAS ALLOW FOR IMPERVIOUS | | | AREA, PUTTING PARKING IN THE PARCEL WOULD REQUIRE A | | | WAIVER FROM THE ADDITIONAL USE STANDARDS, SEE SEC. | | | 94-273 (D)(54.1)(B) WHICH STATES THAT NO PARKING SHALL | | | BE PROVIDED. | | | A. THIS STANDARD IS WAIVABLE BY THE ZONING BOARD OF | | | APPEALS, BUT SEEING AS YOU HAVE EXCEEDED YOUR REQUIRED | | | PARKING STAFF WOULD ENCOURAGE YOU TO KEEP THIS AREA AS | | | JUST AN ACCESS POINT AND NOT ALLOW FOR ANY PARKING. | | | 5. PORTIONS OF THE NORTHWEST SIDE OF THE PROPOSED | | | COMMUNITY CENTER GO UP TO HE MINIMUM SIDE SETBACK, | | | THEREFORE YOU WILL NEED TO CONFIRM THE ROOF OVERHANG | | | ENCROACHES NO MORE THAN 3 FT INTO THE SIDE SETBACK. | | | 6. CONFIRM THAT THE OUTDOOR STAIRCASES ARE NOT TALLER | | | THAN 3 FT. IF THEY ARE, THEY WILL NEED TO MEET PRIMARY | | | STRUCTURE SETBACKS. | | | 7. IS THE DUMPSTER ON THE SITE PLAN EXISTING OR | | | PROPOSED? IF NOT EXISTING, PROVIDE DETAILS SHWING | | | COMPLIANCE WITH LATEST REVISION OF CITY OF WEST PALM | | | BEACH GENERAL CONSTRUCTION-GARBAGE ENCLOSURE STANDARD, | | | GC-7. | | | 8. PROVIDE THE SCREENING DETAILS OF THE WALL | | | SURROUNDING THE HILLER SO STAFF CAN CONFIRM IT IS | | | PROPERLY SCREENED. | | | | | | | | | - WHEN RESUBMITTING, PLEASE PROVIDE A MINIMUM OF THREE | | | (3) PAPER COPIES AND AN ELECTRONIC COPY IN .PNG/.PDF | | | FORMAT OF ALL PLANS. PLEASE NOTE THAT CHANGES ON THE | | | RESUBMITTED PLANS OR THE SUBMITTAL OF INFORMATION/PLANS | | | TO ADDRESS THE COMMENTS MAY RESULT IN ADDITIONAL | | | COMMENTS. | | | | | | | | | - PLEASE NOTE THAT IF THE PLANNING DIVISION HAS NOT | | | RECEIVED A RESPONSE TO THE PPRC COMMENTS/REVIEW | | | COMMENTS WITHIN 60 DAYS FROM THE DATE OF THE PPRC | | | MEETING/COMMENT ISSUANCE (BY 12/13), THE PLANNING | | | DIVISION MAY NOTIFY THE APPLICANT THAT THE CASE IS | | | CONSIDERED WITHDRAWN. ANY FURTHER ACTION SHALL REQUIRE | | | A NEW DEVELOPMENT APPLICATION. | | | | | | - PLEASE NOTE THAT YOU WILL BE PERMITTED ONE (1) | | | RESUBMITTAL AT NO ADDITIONAL COST. IF PREVIOUSLY ISSUED | | | COMMENTS CONTINUE TO NOT BE SUFFICIENTLY ADDRESSED, THE | | | APPLICANT WILL BE ASSESSED A RESUBMITTAL FEE. SUCH FEE | | | WILL BE 20% OF THE ORIGINAL APPLICATION FEE | | | |
|
|
| |