Plan Review Details - Project Z22090015
| Plan Review Stops For Project Z22090015 |
| Review Stop |
AIPP |
ART IN PUBLIC PLACES |
| Rev No |
2 |
Status |
F |
Date |
05-24-2023 |
|
|
Cont ID |
|
| Sent By |
swelter |
Date |
05-24-2023 |
Time |
12:53 |
Rev Time |
0.00 |
| Received By |
swelter |
Date |
05-24-2023 |
Time |
13:05 |
Sent To |
|
|
| Notes |
| 2023-05-24 13:05:25 | THE REVISED DEVELOPMENT PLAN DOES NOT IDENTIFY A PLACE | | | HOLDER FOR PUBLIC ART AS REQUIRED FOR SITE PLAN | | | APPROVAL. | | | OPTION 2 - CONTRIBUTION INTO THE PUBLIC ART IS HIGHLY | | | ENCOURAGED DUE TO SPACE LIMITATIONS TO MEET THE | | | LOCATION AND ACCESSIBILITY PUBLIC ART REQUIREMENT. | | | | | | CONTACT [email protected] FOR AN ART ASSESSMENT | | | APPLICATION. | | | |
|
|
| Review Stop |
AIPP |
ART IN PUBLIC PLACES |
| Rev No |
1 |
Status |
F |
Date |
10-11-2022 |
|
|
Cont ID |
|
| Sent By |
swelter |
Date |
10-11-2022 |
Time |
13:45 |
Rev Time |
0.00 |
| Received By |
relizond |
Date |
10-11-2022 |
Time |
13:57 |
Sent To |
|
|
| Notes |
| 2022-10-11 13:57:23 | PUBLIC ART REQUIREMENT: | | | | | | TOTAL CONSTRUCTION COSTS OF THIS DEVELOPMENT ARE OVER | | | $500,000 IT IS SUBJECT TO THE PUBLIC ART REQUIREMENT AS | | | PER CITY ORDINANCE. | | | | | | OPTION 1: INSTALL ARTWORK ON THE DEVELOPMENT SITE | | | VALUED IN AN AMOUNT NOT LESS THAN ONE PERCENT OF THE | | | TOTAL CONSTRUCTION COSTS. | | | | | | FOR SITE PLAN APPROVAL PUBLIC ART NEEDS TO BE | | | IDENTIFIED ON ALL THE SITE PLANS. | | | | | | OPTION 2: CONTRIBUTE AN AMOUNT EQUAL TO 75 PERCENT OF | | | ONE PERCENT OF THE TOTAL CONSTRUCTION COSTS FOR DEPOSIT | | | TO THE PUBLIC ART ACCOUNT. | | | | | | FOR EITHER OPTION A COMPLETED PUBLIC ART ASSESSMENT | | | APPLICATION ALONG WITH EITHER THE ESCROW OF THE 1% OR | | | IF CHOSEN OPTION 2 CONTRIBUTION INTO THE PUBLIC ART | | | FUND IS REQUIRED AT TIME OF BUILDING PERMIT SUBMITTAL. | | | | | | CONTACT SYBILLE WELTER, ADMINISTRATOR OF PUBLIC ART & | | | CULTURE AT [email protected] WITH FURTHER QUESTIONS. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
10-12-2022 |
|
|
Cont ID |
|
| Sent By |
rbrown |
Date |
10-12-2022 |
Time |
21:05 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
10-12-2022 |
Time |
21:05 |
Sent To |
|
|
| Notes |
| 2022-10-12 21:15:43 | DEVELOPMENT SERVICES DEPARTMENT, BUILDING DIVISION, | | | COMMENTS: | | | | | | 1. THIS REVIEW IS A CURSORY REVIEW AS IT RELATES TO THE | | | SITE. IT IS NOT A REVIEW FOR FULL COMPLIANCE WITH | | | FLORIDA BUILDING CODE. THE FOLLOWING COMMENTS ARE TO BE | | | ADDRESSED FOR THE BUILDING PERMIT APPLICATION. | | | | | | 2. NUMBER OF ACCESSIBLE PARKING SPACES. PROJECT DATA, | | | SHEET A1.00, SHOWS 174 PARKING SPACES BUT DOES NOT SHOW | | | ANY ACCESSIBLE PARKING SPACES. GROUND FLOOOR PLAN, | | | SHEET A3.01, SHOWS 4 ACCESSIBLE PARKING SPACES WHIC | | | MEETS THE MINIMUM NUMBER REQUIRED BY FAIR HOUSING ACT. | | | | | | 3. ELECTRIC VEHICLE CHARGING STATION. IF ELECTRIC | | | VEHICLE (EV) CHARGING STATIONS ARE PROVIDED AT LEAST 1 | | | IN 25 MUST COMPLY WITH ACCESSIBLE PARKING SPACE | | | REQUIREMENTS. | | | | | | 4. BUILDING SIZE. WHEN SUBMITTED FOR BUILDING PERMIT, | | | THE PLANS SHALL SHOW THAT THE TYPE OF CONSTRUCTION FOR | | | THE BUILDINGS WILL BE IN ACCORDANCE WITH THE HEIGHT, | | | AREA AND OCCUPANCY LIMITATIONS IN CHAPTER 5 OF THE | | | FLORIDA BUILDING CODE. | | | | | | 5. BUILDING LOCATION RELATIVE TO THE PROPERTY LINE AND | | | OTHER STRUCTURES. WHEN SUBMITTED FOR BUILDING PERMIT, | | | COMPLIANCE WITH ALL BUILDING SEPARATION, PERCENTAGE OF | | | OPENINGS AND OPENING PROTECTIVE REQUIREMENTS OF | | | CHAPTERS 6 AND 7 OF THE FLORIDA BUILDING CODE SHALL BE | | | VERIFIED. | | | | | | 6. ENCLOSED PARKING GARAGES. IF THE PARKING GARAGE DOES | | | NOT HAVE WALL OPENINGS, OR SUFFICIENT WALL OPENINGS TO | | | MEET THE DEFINITION OF AN OPEN PARKING GARAGE, IT WILL | | | BE CONSIDERED AN ENCLOSED PARKING GARAGE AND MUST HAVE | | | EXHAUST SYSTEMS. THE EXHAUST SYSTEMS SHALL BE DESIGNED | | | TO MINIMIZE NOISE LEVELS USING INLINE FAN SILENCERS OR | | | OTHER APPROVED METHODS. | | | | | | 7. GREASE INTERCEPTOR. IF ANY IF THE RETAIL SPACES WILL | | | BE RESTAURANT USE A GREASE INTERCEPTOR WILL BE | | | REQUIRED. FOR INFORMATION ON THE REQUIRED TYPE, SIZE | | | AND LOCATION, PLEASE CONTACT RYAN BROWN, CHIEF PLUMBING | | | INSPECTOR, DEVELOPMENT SERVICES DEPARTMENT, AT (561) | | | 805-6692, OR BY EMAIL: [email protected] | | | | | | 8. SEPARATE PERMITS REQUIRED. ALL APPLICABLE PERMITS | | | AND SUB-PERMITS MUST BE OBTAINED BEFORE COMMENCING THE | | | WORK. SEPARATE PERMITS, PLANS AND FEES, ARE REQUIRED | | | FOR SIGNS, SWIMMING POOLS AND SPAS, GAS SYSTEMS, | | | GENERATORS, FIRE ALARM SYSTEMS, FIRE SPRINKLER AND | | | OTHER FIRE SUPPRESSION SYSTEMS, GREASE INTERCEPTORS, | | | SITE LIGHTING, SITE LANDSCAPE, SITE IRRIGATION, ETC. | | | | | | 9. CONTRACTOR VEHICLE PARKING. PROPERTY OWNER AND | | | CONTRACTOR SHALL MAKE ARRANGEMENTS FOR PARKING OF | | | CONTRACTOR VEHICLES TO MINIMIZE THE IMPACT ON ALL | | | NEIGHBORING PROPERTIES. | | | | | | 10. PROTECTION OF NEIGHBORING PROPERTY. PROPERTY OWNER | | | AND CONTRACTOR SHALL PROTECT ALL NEIGHBORING PROPERTY, | | | INCLUDING VEHICLES, FROM DAMAGE OR DIRT CAUSED BY THE | | | CONSTRUCTION, AND SHALL NOTIFY THE OCCUPANTS OF | | | NEIGHBORING PROPERTIES ABOUT ALL STAGES OF CONSTRUCTION | | | THAT MAY AFFECT THE USE OF THEIR PROPERTY. | | | | | | 11. BUILDING ADDRESS. EACH SEPARATE BUILDING, AND UNIT | | | WITH AN INDEPENDENT ENTRANCE FROM THE STREET, SHALL | | | HAVE A SEPARATE ADDRESS ASSIGNED BASED ON THE LOCATION | | | OF THE BUILDING ENTRANCE. FOR STREET ADDRESSING, | | | CONTACT CAROLINE PUELL, ADDRESSING COORDINATOR, AT | | | (561) 805 6659, OR BY EMAIL: [email protected] | | | | | | 12. ART IN PUBLIC PLACES. THIS PROJECT WILL BE SUBJECT | | | TO ART LIFE ASSESSMENT UNDER THE CITY OF WEST PALM | | | BEACH ART IN PUBLIC PLACES (AIPP) PROGRAM. FOR ADVICE | | | ON THE PROVISION OF PUBLIC ARTWORK IN LIEU OF THE AIPP | | | ASSESSMENT, CONTACT SYBILLE WELTER, ART IN PUBLIC | | | PLACES COORDINATOR, AT (561) 822-1521, OR BY EMAIL: | | | [email protected] | | | | | | ROBERT BROWN | | | BUILDING OFFICIAL | | | TEL: 561 805 6652 | | | EMAIL: [email protected] | | | |
|
|
| Review Stop |
ENG - PPRC |
ENGINEERING - PPRC |
| Rev No |
4 |
Status |
P |
Date |
05-23-2023 |
|
|
Cont ID |
|
| Sent By |
lquinone |
Date |
05-23-2023 |
Time |
12:34 |
Rev Time |
0.00 |
| Received By |
lquinone |
Date |
05-23-2023 |
Time |
12:34 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
ENG - PPRC |
ENGINEERING - PPRC |
| Rev No |
3 |
Status |
F |
Date |
03-27-2023 |
|
|
Cont ID |
|
| Sent By |
rrossano |
Date |
03-27-2023 |
Time |
|
Rev Time |
0.00 |
| Received By |
rrossano |
Date |
03-27-2023 |
Time |
|
Sent To |
|
|
| Notes |
| 2023-03-27 11:56:56 | WAITING ON PROVISION OF CCTV AND REPORTS. |
|
|
| Review Stop |
ENG - PPRC |
ENGINEERING - PPRC |
| Rev No |
2 |
Status |
F |
Date |
12-13-2022 |
|
|
Cont ID |
|
| Sent By |
rrossano |
Date |
12-13-2022 |
Time |
|
Rev Time |
0.00 |
| Received By |
rrossano |
Date |
12-13-2022 |
Time |
|
Sent To |
|
|
| Notes |
| 2022-12-13 07:19:15 | Z22090015 ??? 120 S DIXIE - 12.13.22 RESUB | | | | | | COMMENT FROM RICK ROSSANO, SR. PROJECT COORDINATOR, | | | ENGINEERING SERVICES AT 561-494-1098 [email protected] | | | | | | PREVIOUS COMMENT, NOT SHOWN IN RESPONSE LETTER DATED | | | 12.09.22: PROVIDE CCTV VIDEO OF EXISTING SANITARY SEWER | | | INFRASTRUCTURE ALONG ENTIRE PROJECT FRONTAGE (CONDITION | | | OF SITE PLAN APPROVAL). CLARIFY IF STORMWATER | | | CONNECTION TO CITY INFRASTRUCTURE IS BEING PROPOSED; | | | CCTV WOULD BE REQUIRED IF SO. | | | | | | |
|
|
| Review Stop |
ENG - PPRC |
ENGINEERING - PPRC |
| Rev No |
1 |
Status |
F |
Date |
09-26-2022 |
|
|
Cont ID |
|
| Sent By |
rrossano |
Date |
09-26-2022 |
Time |
|
Rev Time |
|
| Received By |
rrossano |
Date |
09-26-2022 |
Time |
|
Sent To |
|
|
| Notes |
| 2022-09-26 13:19:44 | COMMENTS FROM RICK ROSSANO, SR. PROJECT COORDINATOR, | | | ENGINEERING SERVICES AT 561-494-1098 [email protected] | | | GENERAL: | | | O PLEASE RESPOND TO ALL COMMENTS IN WRITING, AND | | | INCLUDE PROJECT NAME, ADDRESS AND PERMIT NUMBER | | | (Z-XXXXXXXX). | | | O THE CITY OF WEST PALM BEACH HAS A NUMBER OF | | | REGULATIONS AND PERMIT REQUIREMENTS WHICH DIRECTLY | | | AFFECT THE DEVELOPMENT AND INSTALLATION OF WATER AND | | | WASTEWATER UTILITIES WITHIN THE CITY. PLEASE SEE | | | DEVELOPMENT PERMIT SUBMITTAL REQUIREMENTS AT THE LINK | | | BELOW: | | | A. HTTP://WPB.ORG/CMSPAGES/GETAMAZONFILE.ASPX?PATH=~\WP | | | B_WEBSITE\MEDIA\ENGINEERING\DEVELOPMENT-APPLICATION-FUL | | | L-PACKAGE_2016.PDF&HASH=7BD4DD7EB6115181D8C5977BCC02A97 | | | B1960045731D3658206F27451722716EF | | | B. THIS AND OTHER RELATED ENGINEERING DOCUMENTS CAN BE | | | FOUND HERE: | | | HTTP://WPB.ORG/DEPARTMENTS/ENGINEERING-PUBLIC-WORKS/FOR | | | MS,-PERMITS-APPLICATIONS | | | C. ALSO SEE: CODE OF ORDINANCES, CITY OF WEST PALM | | | BEACH, FLORIDA, CODIFIED THROUGH ORD. NO. 4183-08, | | | ADOPTED SEPT. 22, 2008. (SUPPLEMENT NO. 18) | | | CHAPTER 90 UTILITIES, ARTICLE I. IN GENERAL, | | | SEC. 90-7. POLICY REGARDING EXTENSION OF WATER OR SEWER | | | SERVICE FACILITIES OF THE CITY. | | | THE WATER AND WASTEWATER SERVICE AGREEMENTS AND THE | | | CONSTRUCTION PERMITS ADDRESS RESERVATION OF CAPACITY | | | BASED ON USAGE, METER SIZE AND FEES, DESIGN STANDARDS, | | | BACKFLOW PREVENTION, FIRE SERVICE AND IRRIGATION. | | | O AS OF DECEMBER 20, 2015, THE CITY OF WEST PALM BEACH | | | CROSS-CONNECTION CONTROL MANUAL HAS BEEN REVISED, | | | STATING "ALL BACKFLOW DEVICES MUST BE LEAD-FREE". FOR | | | MORE INFORMATION, REFER TO THE LINK BELOW: | | | A. HTTP://WPB.ORG/DEPARTMENTS/PUBLIC-UTILITIES/FORMS-PU | | | BLICATIONS/BACKFLOW-CROSS-CONNECTION- CONTROL-MANUAL | | | O PLEASE SUBMIT A FORMAL AS-BUILT REQUEST FOR ALL CITY | | | OF WEST PALM BEACH-OWNED UTILITIES WITHIN THE PUBLIC | | | RIGHT OF WAY FOR THE ENTIRE EXTENT OF THE LIMITS OF | | | YOUR PROJECT. IDENTIFY TYPE OF UTILITY, LOCATION, PIPE | | | MATERIAL, AGE AND SIZE. PLEASE CONTACT JANICE TARBILL | | | IN THE WPB ENGINEERING SERVICES DEPARTMENT AT | | | [email protected] OR 561-494-1079 FOR FURTHER | | | ASSISTANCE. NOTE THAT FIELD RECORDS ARE FOR INFORMATION | | | ONLY. FIELD VERIFY UTILITY LOCATIONS USING FIELD | | | SURVEY, POT-HOLING, SOFT DIGS ETC. | | | O PROVIDE EXISTING AND PROPOSED PERVIOUS AND IMPERVIOUS | | | DATA. | | | | | | BACKFLOW ASSEMBLY AND METERS: | | | O SHOW AND LABEL ANY EXISTING OR PROPOSED WATER | | | SERVICES AND WATER METERS, ALONG WITH WHAT IS HAPPENING | | | TO THEM. | | | O SHOW EXISTING AND PROPOSED DEDICATED UTILITY | | | EASEMENTS TO ALLOW ACCESS FOR CITY PERSONNEL TO | | | PROPOSED UTILITY WATER METERS. VERIFY THAT THERE ARE NO | | | STRUCTURES WITHIN EASEMENT. | | | O PROVIDE ENLARGED VIEW ON PLANS OF PROPOSED LOCATION | | | OF WATER METER AND BACKFLOW | | | PREVENTION. | | | O BACKFLOWS SHALL BE INSTALLED ON PRIVATE PROPERTY | | | OUTSIDE OF EASEMENTS AND RIGHTS OF WAY. DOMESTIC WATER | | | METERS SHALL BE INSTALLED IMMEDIATELY ADJACENT TO | | | PROPERTY LINE. 3 INCH AND LARGER WATER METERS SHALL BE | | | INSTALLED ABOVE-GROUND ONLY. | | | O CALLOUT DOMESTIC BACKFLOW PREVENTER AS RPPA (MAKE | | | NOTE USC APPROVED) AND FIRE BACKFLOW PREVENTER AS DCDA. | | | | | | WATER/WASTEWATER PLAN: | | | O PROVIDE VERTICAL DATUM AND DATUM CONVERSION | | | INFORMATION (NAVD 1988 AND NGVD 1929). | | | O SHOW PROJECT ADDRESS ON ALL PLAN SHEETS. | | | O PROVIDE LEGEND ON ALL PLAN SHEETS TO INCLUDE | | | STREETLIGHT, SIGN POSTS, TRANSFORMER BOXES ETC. | | | O PLANS SHALL SHOW EXISTING AND PROPOSED LOCATIONS AND | | | DIMENSIONS OF ALL WATER, STORMWATER, AND SANITARY AND | | | SEWER LINES AND CLEANOUTS, INCLUDING STUBS TO EACH | | | PROPERTY LINE FOR WATER AND SANITARY SEWERS, THE MAKE | | | AND MODEL OF ALL VALVES, POTABLE AND IRRIGATION METERS, | | | BACKFLOWS, FIRE HYDRANTS AND FDCS, AND OTHER DEVICES TO | | | BE INSTALLED ON THE SYSTEM, CATCH BASINS, CULVERTS, | | | DITCHES INCLUDING GRADES, PIPES SIZES, MATERIALS, | | | ELEVATIONS, ASSUMPTIONS, CALCULATIONS, INVERT | | | ELEVATIONS FOR ALL INLETS AND MANHOLES AND PROFILES OF | | | SANITARY SEWER LINES. | | | O GATE VALVE BOXES SHALL NOT BE INSTALLED IN CURB OR | | | SIDEWALK. ALL AVAILABLE ELEVATION SHALL BE SHOWN ON THE | | | PROFILE VIEW. | | | O DIRECTION OF FLOW SHALL BE SHOWN ON PLAN VIEW ON PLAN | | | VIEW FOR ALL SANITARY AND STORM SEWERS. | | | O SHOW SLOPE % ON ALL SANITARY LINES AND CALL OUT | | | MATERIAL. | | | O PLAN VIEW SHALL SHOW ALL EXISTING AND PROPOSED | | | UNDERGROUND UTILITY LAYOUT, INCLUDING FIBER OPTIC, | | | ELECTRIC, GAS, AND CABLEVISION & TELECOMMUNICATION | | | FACILITIES INCLUDING PIPE SIZE AND MATERIAL LOCATED IN | | | THE RIGHT-OF-WAY. | | | O PROVIDE PROFILE AND CLEARANCES BETWEEN WATER, SEWER | | | AND STORM LINES PER CITY OF WEST PALM BEACH STANDARD | | | DETAIL GN-2 SERIES, AT ALL UTILITY CROSSINGS. PLEASE | | | INCLUDE FIBER OPTIC, ELECTRIC, GAS, AND CABLEVISION & | | | TELECOMMUNICATION FACILITIES INCLUDING PIPE SIZE AND | | | MATERIAL LOCATED IN THE RIGHT-OF-WAY. | | | O SUBMIT COMPLETED LOS ANALYSIS SUMMARY TABLE DIRECTLY | | | TO ENGINEERING (SHEET 33 OF CITY OF WPB DEVELOPMENT | | | APPLICATION). PROVIDE CALCULATIONS ON PLANS OF EXISTING | | | AND PROPOSED DEMANDS FOR WATER & SEWER (AVERAGE, | | | MAXIMUM AND PEAK) AND FIRE FLOW DEMANDS. CALCULATIONS | | | SHALL BE PER FAC 64E-6 FOR SEWER AND PER FAC 64-E.008 | | | FOR WATER. | | | O PROVIDE FIRE FLOW TEST DATA. | | | O PROVIDE CCTV VIDEO OF EXISTING SANITARY SEWER | | | INFRASTRUCTURE ALONG ENTIRE PROJECT FRONTAGE (CONDITION | | | OF SITE PLAN APPROVAL). CLARIFY IF STORMWATER | | | CONNECTION TO CITY INFRASTRUCTURE IS BEING PROPOSED; | | | CCTV WOULD BE REQUIRED IF SO. | | | O CUT AND CAP UTILITIES NOT IN USE AND REMOVE ANY | | | ABANDONED UTILITY LINES LARGER THAN 2 INCHES FROM CITY | | | ROW. | | | O WHEN PROPOSED, WATER MAINS IN CITY RIGHT OF WAY SHALL | | | BE MADE OF DUCTILE IRON PIPE (NOT PVC) AND SPECIFY | | | PROPOSED LENGTH IN FEET. | | | O CHECK TO SEE IF FDEP FORMS FOR PROPOSED SANITARY | | | SEWER ARE REQUIRED. | | | O PROVIDE CLEANOUTS FOR PROPOSED SANITARY LINE ONSITE | | | JUST INSIDE PROPERTY LINE, AT JOINTS AND EVERY 75 FEET. | | | O ADD NOTE TO PLANS SPECIFYING CITY???S DOWNSTREAM LIFT | | | STATION NUMBER. | | | O PROVIDE ONSITE CLEANOUTS NEAR PROPERTY LINE FOR | | | PROPOSED SANITARY LATERALS. | | | O LABEL WATER LINES AS PRIVATE WHERE APPLICABLE. | | | O PLEASE SHOW AND LABEL EXISTING AND PROPOSED GREASE | | | TRAPS (IF ANY). | | | O PER CITY STANDARDS MAINTAIN MINIMUM DISTANCE BETWEEN | | | OUTSIDE DIAMETER OF CITY PIPE AND ROOT BARRIER. | | | | | | FORMAL ENGINEERING REVIEW: | | | O FOR FORMAL ENGINEERING SUBMITTAL, SFWMD ERP AND NPDES | | | NOI REQUIREMENTS WILL BE ENFORCED. | | | - AN NOI IS REQUIRED FOR PROJECTS THAT: | | | - 1) DISTURB ONE OF MORE ACRES OF LAND OR DISTURB LESS | | | THAN ON ACRE OF LAND BUT ARE PART OF A COMMON PLAN OF | | | DEVELOPMENT OR SALE; | | | - 2) DISCHARGE STORMWATER TO SURFACE WATERS OF THE | | | STATE OR TO SURFACE WATERS OF THE STATE THROUGH A | | | MUNICIPAL SEPARATE STORM SEWER SYSTEM (MS4). | | | - THE SFWMD ERP CAN BE OBTAINED THROUGH A 10-2 SELF | | | CERTIFICATION THROUGH FDEP OR AN ERP APPLICATION | | | THROUGH SFWMD. EITHER WAY, THE DEVELOPER/ENGINEER SHALL | | | SUBMIT A COPY OF THE ERP PERMIT OR FDEP ACKNOWLEDGEMENT | | | OF THE 10-2 CERTIFICATION. | | | O FOR FORMAL ENGINEERING SUBMITTAL, PLEASE PROVIDE | | | EASEMENT FOR PLACEMENT OF PROPOSED WATER METERS. | | | O FOR FORMAL ENGINEERING SUBMITTAL, PROVIDE PROFILES OF | | | WATER AND SEWER AND SHOW ANY CROSSINGS/CONFLICTS. | | | O FOR FORMAL ENGINEERING SUBMITTAL, WHEN SUBMITTING | | | APPROVED MATERIALS LIST, PLEASE PROVIDE MATERIAL/CUT | | | SHEETS FOR ALL PROPOSED BACKFLOW DEVICES SHOWING | | | SPECIFIC MODEL NUMBER AND SPECIFYING USC APPROVED | | | LEAD-FREE DESIGN. | | | O FOR FORMAL ENGINEERING SUBMITTAL, IF SANITARY LINES | | | ARE PROPOSED IN ROW PLEASE SHOW ADJACENT SANITARY | | | LATERAL LOCATIONS AND SHOW ADDRESSES OF ADJACENT | | | PARCELS. | | | O FOR FORMAL ENGINEERING SUBMITTAL, IF WATER LINES ARE | | | BEING REPLACED IN ROW, SHOW ADJACENT PARCEL ADDRESSES. | | | O FOR FORMAL ENGINEERING SUBMITTAL, ADD NOTE TO PROVIDE | | | 50 FT. PAVEMENT RESTORATION TRANSITION ON EACH SIDE OF | | | PROPOSED TRENCH IN CITY MAINTAINED ROADWAY AREAS PER | | | CITY OF WPB STANDARD DETAIL GC-8. | | | O FOR FORMAL ENGINEERING SUBMITTAL, PLEASE PROVIDE | | | CALCULATIONS OF PERVIOUS AND IMPERVIOUS AREAS FOR | | | PROPOSED IMPROVED AREAS. | | | | | | QUESTIONS AND COORDINATION CONTACTS: | | | O MARK HURLEY, FIELD CUSTOMER SERVICE SUPERVISOR WITH | | | CITY OF WPB PUBLIC UTILITIES, REGARDING PLACEMENT OF | | | BACKFLOW DEVICES AND WATER METERS. CONTACT HIM AT | | | 561-822-2262 OR [email protected] | | | O MIKE TECHNOW, PROJECT ENGINEER, PUBLIC UTILITIES | | | DEPARTMENT AT 561-494-1047 OR [email protected] | | | O TRACY WARD, SR. STORMWATER ENGINEER, ENGINEERING | | | SERVICES DEPT. AT 561-494-1120 OR [email protected] | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
09-29-2022 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
09-29-2022 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
09-29-2022 |
Time |
14:07 |
Sent To |
|
|
| Notes |
| 2022-09-29 14:18:02 | THE FOLLOWING COMMENTS WERE SUBMITTED BY PETER LEDUC, | | | FIRE MARSHAL, BUREAU OF FIRE PREVENTION, WEST PALM | | | BEACH FIRE RESCUE. | | | | | | THIS REVIEW CAN ONLY BE CONSIDERED PRELIMINARY AS THE | | | DRAWINGS THAT WERE REVIEWED WERE NOT COMPLETE. | | | ADDITIONAL COMMENTS CAN BE EXPECTED WHEN FULL DRAWINGS | | | ARE SUBMITTED FOR PERMIT. | | | | | | THE FIRE PREVENTION BUREAU HAS NO OBJECTIONS TO THE | | | PROPOSED PROJECT; HOWEVER, THE FOLLOWING COMMENTS ARE | | | PROVIDED AND MAY NEED FURTHER CLARIFICATIONS WHERE | | | APPLICABLE. | | | | | | 1. CONSTRUCTION, DEMOLITION, AND RENOVATION TO COMPLY | | | WITH NFPA 241. EXTRA ATTENTION SHALL BE GIVEN TO THE | | | PERMITTING AND LOCATION OF CONSTRUCTION TRAILERS. A | | | PERMIT IS REQUIRED FOR ANY CONSTRUCTION TRAILER RELATED | | | TO THIS PROJECT. SEPARATION DISTANCES FROM MAIN | | | STRUCTURES AS WELL AS OTHER TRAILERS SHALL BE CLOSELY | | | MONITORED FOR THE REQUIREMENTS OF FIRE SPRINKLER | | | PROTECTION. | | | | | | 2. SITE ACCESS AND EXIT POINTS ARE TO BE CLEARLY | | | IDENTIFIED AND MAINTAINED FOR EMERGENCY VEHICLES DURING | | | ALL CONSTRUCTION ACTIVITIES. | | | | | | 3. THE BUILDING ADDRESS SHALL BE CLEARLY VISIBLE FROM | | | ALL ACCESS ROADWAYS, INCLUDING DURING CONSTRUCTION. | | | ADDRESS NUMBERS SHALL CONTRAST WITH THEIR BACKGROUND | | | AND SHALL NOT BE LESS THAN SIX (6) INCHES IN HEIGHT | | | WITH A ONE (1) INCH STROKE FOR ALL BUILDINGS. | | | | | | 4. DURING CONSTRUCTION, TRASH AND DEBRIS IS TO BE | | | REMOVED FROM THE SITE DAILY OR MORE OFTEN TO REDUCE THE | | | ACCUMULATION OF POTENTIAL LIFE AND FIRE SAFETY HAZARDS. | | | | | | 5. THE CONSTRUCTION OF THE BUILDING SHALL COMPLY WITH | | | THE 7TH EDITION OF THE FLORIDA FIRE PREVENTION CODE, | | | INCLUDING NFPA 1 & 101, AND ALL ASSOCIATED FIRE CODES. | | | | | | 6. ALL PARKING STRUCTURES SHALL COMPLY WITH NFPA 88A, | | | PARKING STRUCTURES AND NFPA 101, THE LIFE SAFETY CODE, | | | INCLUDING MORE SPECIFICALLY, CHAPTER 42 STORAGE | | | OCCUPANCIES (PARKING STRUCTURES) | | | | | | 7. A NFPA 13 COMPLAINT FIRE SPRINKLER SYSTEM AND NFPA | | | 14 COMPLIANT WET STANDPIPE SYSTEM ARE REQUIRED FOR THIS | | | STRUCTURE. TEMPORARY STANDPIPES ARE REQUIRED WHEN THE | | | BUILDING REACHES THREE LEVELS OR THIRTY FEET WHILE | | | BEING CONSTRUCTED. | | | | | | SEPARATE SHOP DRAWINGS, ARE REQUIRED TO BE SUBMITTED, | | | REVIEWED AND APPROVED BY THE FIRE PREVENTION BUREAU | | | PRIOR TO ANY INSTALLATION. | | | | | | 7A. THERE WERE NO INDICATIONS FOR THE LOCATION OF ANY | | | FDC. | | | | | | PLEASE COORDINATE THE LOCATION(S) WITH THE OFFICE OF | | | THE FIRE MARSHAL. | | | | | | PER NFPA 14 | | | 6.4.5.4* FIRE DEPARTMENT CONNECTIONS SHALL BE LOCATED | | | NOT MORE THAN 100 FT (30.5 M) FROM THE NEAREST FIRE | | | HYDRANT CONNECTED TO AN APPROVED WATER SUPPLY. | | | | | | 7B. PER NFPA 1 | | | 18.3 WATER SUPPLIES. | | | | | | 18.3.1* AN APPROVED WATER SUPPLY CAPABLE OF SUPPLYING | | | THE REQUIRED FIRE FLOW FOR FIRE PROTECTION SHALL BE | | | PROVIDED TO ALL PREMISES UPON WHICH FACILITIES, | | | BUILDINGS, OR PORTIONS OF BUILDINGS ARE HEREAFTER | | | CONSTRUCTED OR MOVED INTO THE JURISDICTION. THE | | | APPROVED WATER SUPPLY SHALL BE IN ACCORDANCE WITH | | | SECTION 18.4. | | | | | | PER FLORIDA ADMINISTRATIVE CODE SECTION 61G15-32.004, | | | FIRE PROTECTION ENGINEERING DOCUMENTS SHALL INCLUDE THE | | | POINT OF SERVICE FOR THE WATER SUPPLY, A LIST OF | | | APPLICABLE NFPA STANDARDS APPLICABLE TO THE PROJECT, | | | CLASSIFICATION OF HAZARD OCCUPANCY FOR EACH ROOM OR | | | AREA, SUPPRESSION SYSTEM TYPE, DESIGN DENSITIES, WATER | | | SUPPLY DATA (FIRE PUMP DATA, HYDRANT FLOW TEST DATA) | | | AND ANY PERFORMANCE BASED INFORMATION SUCH AS | | | PRE-ENGINEERED SYSTEMS. | | | FOR THE PROPOSED FIRE PUMP(S) , WHAT IS(ARE) THE | | | PRIMARY AND SECONDARY POWER SOURCES? | | | | | | 7C. THERE WERE NO INDICATIONS FOR THE LOCATION OF THE | | | FIRE DDCV. | | | | | | THE LOCATION OF THE DDCV FIRE LINE LOCATION SHALL MEET | | | THE REQUIREMENTS OF NFPA 24 AND SHALL BE COORDINATED | | | WITH THE OFFICE OF FIRE MARSHAL, THE CITY'S ENGINEERS | | | OFFICE, THE LANDSCAPE PLANNER, AND THE CITY'S PLANNING | | | AND ZONING OFFICE. | | | | | | 8. A NFPA 72 COMPLIANT MONITORED FIRE ALARM SYSTEM IS | | | REQUIRED FOR THIS STRUCTURE. SEPARATE SHOP DRAWINGS, | | | ARE REQUIRED TO BE SUBMITTED, REVIEWED AND APPROVED BY | | | THE FIRE PREVENTION BUREAU PRIOR TO ANY INSTALLATION. | | | | | | 9. ALL ELEVATORS SHALL BE EQUIPPED WITH A REGION 7 | | | KEYWAY SYSTEM FOR BUILDING 6 OR MORE STORIES. | | | | | | ALL NEW ELEVATORS SHALL CONFORM TO THE FIRE FIGHTER???S | | | EMERGENCY OPERATIONS REQUIREMENTS OF ASME A17.1/CSA | | | B44, SAFETY CODE FOR ELEVATORS. | | | | | | ANY BUILDING THAT IS MORE THAN THREE STORIES HIGH OR IN | | | WHICH THE VERTICAL DISTANCE BETWEEN THE BOTTOM TERMINAL | | | LANDING AND THE TOP TERMINAL LANDING EXCEEDS 25 FEET | | | MUST BE CONSTRUCTED TO CONTAIN AT LEAST ONE PASSENGER | | | ELEVATOR THAT IS OPERATIONAL AND WILL ACCOMMODATE AN | | | AMBULANCE STRETCHER 76 INCHES LONG AND 24 INCHES WIDE | | | IN THE HORIZONTAL POSITION. | | | | | | 10. COMPLETE LIFE SAFETY PLANS FOR EACH OCCUPANCY SHALL | | | BE PROVIDED THAT ILLUSTRATE OCCUPANT LOADS, TRAVEL | | | DISTANCES, COMMON PATHS OF TRAVEL, DEAD-END CORRIDORS, | | | EXIT SIGNS, EMERGENCY LIGHTING, EXITS LEADING TO A | | | PUBLIC WAY, FIRE EXTINGUISHER LOCATIONS, AND ALL FIRE | | | SAFETY FEATURES AND EQUIPMENT. | | | | | | 11. ALL EXISTING AND NEW FIRE HYDRANTS PLANNED FOR THIS | | | DEVELOPMENT SHALL BE CLEARLY INDICATED AND IDENTIFIED | | | ON THE PLAN AND CLOSELY COORDINATED WITH THE BUREAU OF | | | FIRE PREVENTION. | | | | | | ALL NEW FIRE HYDRANTS AND FDC???S PLANNED FOR THIS | | | DEVELOPMENT SHALL BE CLOSELY COORDINATED WITH THE | | | BUREAU OF FIRE PREVENTION. PROPOSED FIRE HYDRANTS AND | | | FDC???S SHOULD BE LOCATED ON THE SAME SIDE OF THE | | | STREET OR ACCESS ROADWAY TO ALLOW FREE ACCESS FOR OTHER | | | ARRIVING EMERGENCY VEHICLES. | | | | | | 12. FIRE COMMAND CENTER/ROOM | | | | | | THE FCC LOCATION IS ACCEPTABLE. IF POSSIBLE, CAN A | | | INTERIOR ACCESS DOOR BE PROVIDED AT THE LOBBY AREA | | | WALL? PLEASE COORIDINATE WITH THE OFFICE OF THE FIRE | | | MARSHAL. | | | | | | THE FIRE COMMAND CENTER SHALL COMPLY WITH NFPA 1, | | | CHAPTER 11, BUILDING SERVICES; 11.9 AND SHALL CONTAIN | | | THE FOLLOWING FEATURES: | | | | | | 11.9.1 THE LOCATION, DESIGN, CONTENT, AND FIRE | | | DEPARTMENT ACCESS OF THE EMERGENCY COMMAND CENTER SHALL | | | BE APPROVED BY THE FIRE DEPARTMENT. | | | | | | 11.9.2 THE EMERGENCY COMMAND CENTER SHALL BE SEPARATED | | | FROM THE REMAINDER OF THE BUILDING BY A FIRE BARRIER | | | HAVING A FIRE RESISTANCE RATING OF NOT LESS THAN 1 | | | HOUR. | | | | | | 11.9.3 THE EMERGENCY COMMAND CENTER ROOM SHALL BE A | | | MINIMUM OF 200 FT2 (19 M2) WITH A MINIMUM DIMENSION OF | | | 10 FT (3050 MM). | | | | | | 11.9.4 THE FOLLOWING SHALL BE PROVIDED IN THE EMERGENCY | | | COMMAND CENTER. | | | (1) THE FIRE DEPARTMENT COMMUNICATIONS SYSTEM. | | | (2) A TELEPHONE FOR FIRE DEPARTMENT USE WITH CONTROLLED | | | ACCESS TO THE PUBLIC TELEPHONE SYSTEM | | | (3) SCHEMATIC BUILDING PLANS INDICATING THE TYPICAL | | | FLOOR PLAN AND DETAILING THE BUILDING CORE, MEANS OF | | | EGRESS, FIRE PROTECTION SYSTEMS, FIRE-FIGHTING | | | EQUIPMENT AND FIRE DEPARTMENT ACCESS | | | (4) WORK TABLE. | | | (5) IF APPLICABLE, A HAZARDOUS MATERIAL MANAGEMENT PLAN | | | FOR THE BUILDING. | | | 11.9.5 WHERE OTHERWISE REQUIRED, THE FOLLOWING DEVICES | | | OR FUNCTIONS SHALL BE PROVIDED WITHIN THE EMERGENCY | | | COMMAND CENTER. | | | (1) THE EMERGENCY VOICE/ALARM COMMUNICATION SYSTEM | | | CONTROL UNIT. | | | (2) FIRE DETECTION AND ALARM SYSTEM ANNUNCIATOR UNIT. | | | (3) ANNUNCIATOR UNIT VISUALLY INDICATING THE LOCATION | | | OF THE ELEVATORS AND WHETHER THEY ARE OPERATIONAL | | | (4) STATUS INDICATORS AND CONTROLS FOR AIR-HANDLING | | | SYSTEMS. | | | (5) CONTROLS FOR UNLOCKING STAIRWAY DOORS | | | SIMULTANEOUSLY | | | (6) SPRINKLER VALVE AND WATER FLOW DETECTOR DISPLAY | | | PANELS | | | (7) EMERGENCY AND STANDBY POWER STATUS INDICATORS | | | (8) FIRE PUMP STATUS INDICATORS | | | (9) GENERATOR SUPERVISION DEVICES AND MANUAL START AND | | | TRANSFER FEATURES. | | | (10) PUBLIC ADDRESS SYSTEM, WHERE SPECIFICALLY REQUIRED | | | BY OTHER SECTIONS OF THIS CODE | | | (11) CONTROLS REQUIRED FOR SMOKE CONTROL | | | | | | NFPA 101 | | | | | | 11.8.6* EMERGENCY COMMAND CENTER. | | | 11.8.6.1 AN EMERGENCY COMMAND CENTER SHALL BE PROVIDED | | | IN A | | | LOCATION APPROVED BY THE FIRE DEPARTMENT. | | | 11.8.6.2 THE EMERGENCY COMMAND CENTER SHALL CONTAIN THE | | | FOLLOWING: | | | (1) VOICE FIRE ALARM SYSTEM PANELS AND CONTROLS | | | (2) FIRE DEPARTMENT TWO-WAY TELEPHONE COMMUNICATION | | | SERVICE | | | PANELS AND CONTROLS WHERE REQUIRED BY ANOTHER SECTION | | | OF THIS | | | CODE | | | (3) FIRE DETECTION AND FIRE ALARM SYSTEM ANNUNCIATION | | | PANELS | | | (4) ELEVATOR FLOOR LOCATION AND OPERATION ANNUNCIATORS | | | (5) ELEVATOR FIRE RECALL SWITCH IN ACCORDANCE WITH ASME | | | A17.1/CSA B44, SAFETY CODE FOR ELEVATORS AND ESCALATORS | | | (6) ELEVATOR EMERGENCY POWER SELECTOR SWITCH(ES) WHERE | | | PROVIDED | | | IN ACCORDANCE WITH ASME A17.1/CSA B44 | | | (7) SPRINKLER VALVE AND WATERFLOW ANNUNCIATORS | | | (8) EMERGENCY GENERATOR STATUS INDICATORS | | | (9) CONTROLS FOR ANY AUTOMATIC STAIRWAY DOOR UNLOCKING | | | SYSTEM | | | (10) FIRE PUMP STATUS INDICATORS | | | (11) TELEPHONE FOR FIRE DEPARTMENT USE WITH CONTROLLED | | | ACCESS TO THE | | | PUBLIC TELEPHONE SYSTEM | | | (12) STAIRWAY VIDEO MONITORING EQUIPMENT AS REQUIRED BY | | | 11.8.8 | | | | | | | | | 13. TWO-WAY RADIO COMMUNICATIONS ENHANCEMENT SYSTEMS. | | | | | | NFPA 1, CHAPTER 11, BUILDING SERVICES; 11.10 TWO-WAY | | | RADIO ENHANCEMENT SERVICES. | | | | | | 11.10.1 IN ALL NEW AND EXISTING BUILDINGS, MINIMUM | | | RADIO SIGNAL STRENGTH FOR FIRE DEPARTMENT | | | COMMUNICATIONS SHALL BE MAINTAINED AT A LEVEL | | | DETERMINED BY THE AHJ. | | | | | | NFPA 72, 24.9 TWO-WAY RADIO COMMUNICATIONS ENHANCEMENT | | | SYSTEMS. | | | 24.9.1 GENERAL. | | | | | | 24.9.1.1 NON-INTERFERENCE. NO AMPLIFICATION SYSTEM | | | CAPABLE | | | OF OPERATING ON FREQUENCIES OR CAUSING INTERFERENCE ON | | | FREQUENCIES | | | ASSIGNED TO THE JURISDICTION BY THE FCC SHALL BE | | | INSTALLED | | | WITHOUT PRIOR COORDINATION AND APPROVAL OF THE | | | AUTHORITY | | | HAVING JURISDICTION. THE BUILDING MANAGER/OWNER SHALL | | | SUSPEND AND CORRECT OTHER EQUIPMENT INSTALLATIONS THAT | | | DEGRADE | | | THE PERFORMANCE OF THE PUBLIC SAFETY RADIO SYSTEM OR | | | PUBLIC SAFETY RADIO ENHANCEMENT SYSTEM. | | | | | | 24.9.1.2 APPROVAL AND PERMIT. PLANS SHALL BE SUBMITTED | | | FOR | | | APPROVAL PRIOR TO INSTALLATION. AT THE CONCLUSION OF | | | SUCCESSFUL | | | ACCEPTANCE TESTING, A RENEWABLE PERMIT SHALL BE ISSUED | | | FOR THE | | | PUBLIC SAFETY RADIO ENHANCEMENT SYSTEM WHERE REQUIRED | | | BY | | | THE AUTHORITY HAVING JURISDICTION. | | | | | | THE SYSTEM SHALL MAINTAIN A MINIMUM RADIO SIGNAL | | | STRENGTH OF THE RADIO SYSTEM USED BY WEST PALM BEACH | | | FIRE DEPARTMENT. TESTING SHALL BE BY AN ACCEPTABLE | | | NATIONAL STANDARD DOCUMENTING PERCENTAGES NOTED ABOVE | | | AND BY ACTUAL RADIO TESTING BY FIRE PERSONNEL. IF THE | | | MINIMUM CANNOT BE MAINTAINED, A BI-DIRECTIONAL | | | AMPLIFIED SYSTEM SHALL BE INSTALLED WITH A MINIMUM | | | 2-HOUR RUN TIME BATTERY BACK-UP. | | | PLEASE CONTACT MARK FILLA, PALM BEACH COUNTY PUBLIC | | | SAFETY RADIO SYSTEMS MANAGER, [email protected], | | | 561-233-0837; AS OUR RADIOS OPERATE ON THEIR SYSTEM FOR | | | DETAILED RADIO FREQUENCY AND INSTALLATION INSTRUCTIONS. | | | | | | | | | 14. KNOX-BOX KEY SYSTEM SHALL BE REQUIRED FOR THIS | | | BUILDING. | | | ANY GATES SHALL BE PROVIDED WITH KNOX KEY ACCESS LOCKS, | | | PADLOCKS AND/OR SWITCHES FOR 24 HOUR EMERGENCY ACCESS. | | | | | | 15. THE SMOKE CONTROL SYSTEM SHALL COMPLY WITH NFPA | | | 101, CHAPTER 9, BUILDING SERVICE AND FIRE PROTECTION | | | EQUIPMENT, INCLUDING: | | | | | | THE SMOKE CONTROL SYSTEMS SHALL BE INSTALLED, | | | INSPECTED, TESTED, AND MAINTAINED IN ACCORDANCE WITH | | | NFPA 92, STANDARD FOR SMOKE CONTROL SYSTEMS; NFPA 204, | | | STANDARD FOR SMOKE AND HEAT VENTING; OR NATIONALLY | | | RECOGNIZED STANDARDS, ENGINEERING GUIDES, OR | | | RECOMMENDED PRACTICES, AS APPROVED BY THE AUTHORITY | | | HAVING JURISDICTION. | | | | | | THE ENGINEER OF RECORD SHALL CLEARLY IDENTIFY THE | | | INTENT OF THE SYSTEM, THE DESIGN METHOD USED, THE | | | APPROPRIATENESS OF THE METHOD USED, AND THE REQUIRED | | | MEANS OF INSPECTING, TESTING, AND MAINTAINING THE | | | SYSTEM. | | | | | | ACCEPTANCE TESTING SHALL BE PERFORMED BY A SPECIAL | | | INSPECTOR IN ACCORDANCE WITH SECTION 9.9. | | | | | | 16. AREAS OF REFUGE SHALL COMPLY WHERE APPLICABLE PER | | | THE BUILDING CODE AND NFPA 101, CH 7, MEANS OF EGRESS. | | | | | | 17. THE BUREAU'S APPROVAL OF THIS SUBMITTED PROJECT | | | DOES NOT CONSTITUTE IT'S FINAL REVIEW OR APPROVAL. | | | | | | 18. THE BUREAU SHALL REVIEW ALL SUBMITTED BUILDING | | | PLANS AT THE APPROPRIATE TIME AND IN ACCORDANCE WITH | | | THE REQUIREMENTS OF ALL APPLICABLE CODES AND STANDARDS. | | | | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
4 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
3 |
Status |
F |
Date |
06-16-2023 |
|
|
Cont ID |
|
| Sent By |
ckimmerl |
Date |
06-02-2023 |
Time |
13:41 |
Rev Time |
0.00 |
| Received By |
ckimmerl |
Date |
06-02-2023 |
Time |
13:41 |
Sent To |
|
|
| Notes |
| 2023-06-16 13:41:37 | 10/05/2022 | | | 1. PARTIALLY SATISFIED. PROVIDE THE INDIVIDUAL AND | | | TOTAL CANOPY MITIGATION DUE FOR ALL PROPOSED REMOVALS. | | | TREES PROPOSED TO BE REMOVED WITH A CANOPY DIAMETER OF | | | 20 FEET OR MORE SHOULD HAVE THE MITIGATION SQUARE | | | FOOTAGE CALCULATED BASED ON THE ACTUAL DIAMETER. TREES | | | LESS THAN 20 FEET CANOPY DIAMETER AND PALMS SHOULD SHOW | | | THE CATEGORY MITIGATION DUE. MAKE THE FOLLOWING | | | CORRECTIONS TO THE TREE DISPOSITION LIST SHEET L-: | | | TREES #1, #4, AND #23 ARE 20 FEET OR ABOVE IN CANOPY | | | DIAMETER, SO MUST HAVE THE ACTUAL CANOPY SQUARE FOOTAGE | | | CALCULATED FOR MITIGATION DUE. TREE#4, 21, 22, 23, AND | | | 24 ARE CATEGORY 2 (150 SQ FT EACH EXCEPT #23 AT 314SQ | | | FT) TREE #9 IS CATEGORY 1 (300 SQ FT) ARECA PALMS DO | | | NOT REQUIRE MITIGATION. (#5, 7, 12, AND 16 NO | | | MITIGATION DUE) #24 DISPOSITION CORRECT TO REMOVE WITH | | | ADJUSTMENTS, TOTAL MITIGATION WAS 7587 SQ FT. ADJUST | | | LIST OF PROVIDED MITIGATION FROM THE PLANT LIST TO | | | IDENTIFY EACH SPECIES AND THE CANOPY CREDIT ASSIGNED TO | | | IT. PROVIDE AN EXPLANATION FOR NOTE #4 REGARDING | | | OFFSITE TREES IN PROXIMITY TO NORTH PROPERTY LINE, AS | | | THERE ARE NO TREES IN THIS AREA. | | | RESPONSE: REVISIONS HAVE BEEN MADE TO ADDRESS THIS | | | COMMENT. REFER TO SHEET L-100. | | | 6.2.23 - ZONING REVIEW ON BEHALF OF LANDSCAPE PLANNER: | | | [SATISFIED] | | | | | | 2. SATISFIED. PER SECTION 94-113 D. ALL STREETSCAPE | | | REQUIREMENTS ARE APPLICABLE TO ANY NEW CONSTRUCTION, | | | RENOVATION OR ADDITION WITH A CONSTRUCTION COST EQUAL | | | OR ABOVE 50% OF THE PROPERTY'S IMPROVEMENT VALUE AS | | | INDICATED BY THE PALM BEACH COUNTY PROPERTY APPRAISER'S | | | OFFICE. EXISTING STREET TREES AND SIDEWALK FOR THIS | | | PROJECT ARE TO BE REMOVED AND REPLACED WITH THE | | | REQUIRED NEW STREET TREES, SIDEWALK, PLANTING BEDS AND | | | STRUCTURAL SOIL. | | | RESPONSE: EXISTING TREES AND SIDEWALK ALONG S DIXIE HWY | | | HAVE BEEN REPLACED WITH NEW LANDSCAPE AND HARDSCAPE. | | | REFER TO SHEET L-200 AND L-300. LIMITS OF STRUCTURAL | | | SOIL OUTLINE HAS BEEN ADDED TO SHEET L-300 AND NOTES ON | | | SHEET L-252 | | | 6.2.23 - ZONING REVIEW ON BEHALF OF LANDSCAPE PLANNER: | | | [PARTIALLY SATISFIED] ADDITIONAL STRUCTURAL SOIL | | | REQUIRED ALONG DATURA FRONTAGE, SPECIFICALLY UNDERNEATH | | | THE SIDEWALK. | | | | | | 3. PARTIALLY SATISFIED. THE ON STREET PARKING SHOWN ON | | | S DIXIE ADJACENT TO THE PROJECT IS NOT POSSIBLE WITHIN | | | THE EXISTING SETBACK FROM THE CURB. STREETSCAPE | | | REQUIREMENTS MUST BE MET WITHIN THIS AREA. IF THERE IS | | | NOT SUFFICIENT WIDTH TO PROVIDE THE PLANTING BED, TREE | | | GRATES MAY BE USED IF REQUIRED FOR SIDEWALK TRAVEL | | | WIDTH. | | | THE REQUIRED PLANTING BED WIDTH OF 4 FEET CANNOT BE | | | ACHIEVED ALONG S DIXIE, SO PARTIAL TREE GRATES MAY BE | | | USED TO PROVIDE SPACE FOR THE TREE TO BE PLACED | | | ADEQUATELY AWAY FROM THE CURB. | | | RESPONSE: ON STREET PARKING HAS BEEN REMOVED AND TREE | | | GRATES HAVE BEEN ADDED REFER TO SHEET L-300. | | | 6.2.23 - ZONING REVIEW ON BEHALF OF LANDSCAPE PLANNER: | | | [SATISFIED] | | | | | | 4. PARTIALLY SATISFIED. PROVIDE CALCULATIONS FOR | | | REQUIRED STREET TREES AT MAXIMUM SPACING EVERY 30 FEET | | | OR PORTION THEREOF FOR EACH STREETSCAPE LENGTH, AND | | | SHOW THE NUMBER PROVIDED PER SECTION 94- 113D.2. CODE | | | SECTION REFERENCE HAS NOT BEEN CORRECTED. SOUTH | | | PROPERTY LINE MEASUREMENT OF 245 FEET LENGTH REQUIRES 9 | | | STREET TREES. | | | RESPONSE: REFER TO SHEET L-200 AND L-201 FOR THE STREET | | | TREE REVISION. | | | 6.2.23 - ZONING REVIEW ON BEHALF OF LANDSCAPE PLANNER: | | | [PARTIALLY SATISFIED] TREE SPACING ALONG DATURA STREET | | | NEEDS TO BE ADJUSTED, TREES ON EITHER SIDE OF DRIVEWAY | | | ARE SPACED FURTHER THAN 30 FT. PLEASE ADJUST. | | | | | | 5. PARTIALLY SATISFIED. PROVIDE A DIAGRAM OF THE | | | REQUIRED AND PROVIDED PUBLIC AND PRIVATE OPEN SPACE | | | AREAS FOR THE ZONING DISTRICT IN THE SITE AND | | | ARCHITECTURAL DRAWINGS. IDENTIFY THE TYPE OF OPEN SPACE | | | AS ALLOWED BY TABLE IV-7 AND DEFINITIONS IN SECTION | | | 94-109. SHOW HOW THE STANDARDS FOR THE TYPES OF OPEN | | | SPACE ARE MET FOR VEGETATED AREAS AND TREE CANOPY | | | SQUARE FOOTAGE BASED ON TABLE IV-8 ON THE LANDSCAPE | | | PLAN. LANDSCAPE PLANS MUST MATCH THE ARCHITECTURAL | | | PLANS AND CLEARLY IDENTIFY THE OPEN SPACE TYPE THEN | | | DEMONSTRATE HOW THE REQUIREMENTS OF THAT TYPE ARE MET. | | | PROVIDE THE INFORMATION ON THE CODE REQUIREMENT CHART | | | ON SHEET L-201. MAKE THE FOLLOWING CORRECTIONS SHEET | | | A0.03: SHEET A0.03 MUST SHOW HOW THE REQUIRED PRIVATE | | | OPEN SPACE OF 9,810 SQ FT IS PROVIDED BY SHOWING THE | | | PERIMETER OF EACH AREA AND THE TOTAL SQUARE FOOTAGE OF | | | EACH SPACE. ROOFTOP GARDEN IS IDENTIFIED, SO AREA | | | PROVIDED MUST BE SHOWN IN, 30% VEGETATED AREA SHOWN, | | | AND 20% TREE CANOPY SHOWN. PASEO-PASSAGE IS NOT AN OPEN | | | SPACE TYPE. SHOW THE AREA AND ASSIGN AN ALLOWED OPEN | | | SPACE TYPE AND SHOW THE REQUIREMENTS FOR VEGETATED AREA | | | AND TREE CANOPY ARE MET. | | | RESPONSE: REFER TO SHEET L-203. | | | 6.2.23 - ZONING REVIEW ON BEHALF OF LANDSCAPE PLANNER: | | | [SATISFIED] | | | | | | 6. NOT SATISFIED. REMOVE THE REFERENCE TO SECTION | | | 94-443(D) FROM THE CODE REQUIREMENT CHART AS THIS IS | | | NOT APPLICABLE IN THE DMP. REMOVE | | | THE SECTION FROM THE CHART ON SHEET L-201 AND REPLACE | | | WITH REQUIREMENTS FROM SECTION 94-113 FOR THE | | | STREETSCAPE AND SECTION 94-109 FOR THE OPEN SPACE | | | REQUIREMENTS. | | | RESPONSE: REFER TO UPDATED CHART ON SHEET L-201. | | | 6.2.23 - ZONING REVIEW ON BEHALF OF LANDSCAPE PLANNER: | | | [NOT SATISFIED] WHAT IS THE REFERENCE TO NATURAL GRASS | | | AREAS? WHERE IS THIS REQUIREMENT FROM? TABLE STATES | | | REQUIREMENT IS 1,515 AND NONE IS PROVIDED? PLEASE | | | CLARIFY THIS REQUIREMENT. LIKELY NOT A DMP REQUIREMENT. | | | | | | | | | 7. PARTIALLY SATISFIED. ALL REQUIRED PUBLIC AND PRIVATE | | | OPEN SPACE TYPES REQUIRING TREE CANOPY MUST SHOW THE | | | TREE CANOPY SQUARE FOOTAGE FOR TREE TYPES BASED ON | | | TABLE IV-8 AND PROVIDE THE TOTAL. TOTALS FOR TREE | | | CANOPY SQUARE FOOTAGE ARE SHOWN ON SHEET A0.03, BUT THE | | | BREAKDOWN OF HOW THAT IS ACHIEVED IS NOT INCLUDED. THIS | | | NEEDS TO BE SHOWN ON SHEET L-210 | | | RESPONSE: REFER TO SHEET L-100 FOR TOTAL CANOPY CREDIT | | | PROVIDED. | | | 6.2.23 - ZONING REVIEW ON BEHALF OF LANDSCAPE PLANNER: | | | [SATISFIED] | | | | | | 8. SATISFIED. ARTIFICIAL TURF AREAS PROPOSED MUST MEET | | | THE REQUIREMENTS OF SECTION 94-451, INCLUDING ALL AREAS | | | THAT ARE ALLOWED BY CODE MUST NOT BE VISIBLE FROM A | | | ROAD OR STREET. | | | RESPONSE: NOTED. THERE IS NO ARTIFICIAL TURF IN THE | | | GROUND FLOOR. | | | 6.2.23 - ZONING REVIEW ON BEHALF OF LANDSCAPE PLANNER: | | | [SATISFIED] | | | | | | 9. ONGOING. EXPLAIN IF THE EXISTING FPL TRANSMISSION | | | LINES WITHIN THE ALLEY WILL STAY IN PLACE OR BE | | | RELOCATED. | | | RESPONSE: TRANSMISSION LINES WITHIN THE ALLEY WILL STAY | | | IN PLACE. | | | 6.2.23 - ZONING REVIEW ON BEHALF OF LANDSCAPE PLANNER: | | | [SATISFIED] | | | | | | 10. PARTIALLY SATISFIED. SHOW ALL EXISTING AND PROPOSED | | | WATER AND SEWER AND DRAINAGE LINES ON THE LANDSCAPE | | | PLAN. SHOW LOCATIONS OF BACKFLOWS AND ADJUST LOCATIONS | | | OF UTILITY LINES TO RESOLVE CONFLICTS WITH EXISTING AND | | | PROPOSED TREES AND LANDSCAPING. FIRELINE FROM DATURA ST | | | APPEARS TO BE IN CONFLICT WITH STREET TREE. ADJUST TO | | | AVOID CONFLICT. WATER METER AND BACKFLOW ARE NOT SHOWN | | | ON LANDSCAPE PLANS AS SHOWN ON CIVIL PLANS. | | | RESPONSE: LANDSCAPE PLANS HAVE BEEN ADJUSTED TO AVOID | | | UTILITY LINES. | | | 6.2.23 - ZONING REVIEW ON BEHALF OF LANDSCAPE PLANNER: | | | [NOT SATISFIED] APPEARS THAT STREET LIGHTS CONFLICT | | | WITH TREES AND THEIR CANOPIES ALONG DATURA FRONTAGE. | | | PLEASE ADJUST. APPEARS THAT SOME WATER MAINS INTERSECT | | | WITH STREET TREE LOCATIONS. | | | | | | 11. SATISFIED. PLANT LIST NEEDS TO BE MODIFIED TO | | | INCLUDE ALL PLANT MATERIAL FOR THE PROJECT, AND | | | SEPARATE PLANT LIST FOR EACH OPEN SPACE AREA PROVIDED | | | FOR REFERENCE TO SHOW COMPLIANCE WITH THE OPEN SPACE | | | TYPE REQUIREMENTS. | | | RESPONSE: A SEPARATE PLANT LIST FOR EACH OPEN SPACE | | | AREA HAS BEEN PROVIDED ON SHEET L-201. | | | 6.2.23 - ZONING REVIEW ON BEHALF OF LANDSCAPE PLANNER: | | | [SATISFIED] | | | | | | 12. PARTIALLY SATISFIED. SHOW COMPLIANCE WITH SECTION | | | 94-445 L. PLANT SPECIES. A MINIMUM OF 60 PERCENT OF | | | PLANT MATERIAL ADDED SHALL BE FLORIDA NATIVE OR DROUGHT | | | TOLERANT SPECIES SELECTED FROM THE CITY LIST OR THE | | | LIST OF SPECIES IN THE MOST RECENT EDITION OF SOUTH | | | FLORIDA WATER MANAGEMENT DISTRICT WATERWISE SOUTH | | | FLORIDA LANDSCAPES. PROVIDE THE ACTUAL PERCENTAGE OF | | | NATIVE AND DROUGHT TOLERANT PLANTS ADDED BASED ON THE | | | PLANT LIST. PROVIDE THE TOTAL PLANT MATERIAL ADDED | | | COUNT AND THE TOTAL NUMBER OF PLANTS THAT ARE DROUGHT | | | TOLERANT OR NATIVE THEN SHOW ONE PERCENTAGE. | | | RESPONSE: PLANTING DESIGN HAS BEEN ADJUSTED TO MEET THE | | | NATIVE AND DROUGHT TOLERANT REQUIREMENT, REFER TO SHEET | | | L-201. | | | | | | 6.2.23 - ZONING REVIEW ON BEHALF OF LANDSCAPE PLANNER: | | | [SATISFIED] | | | | | | 13. PARTIALLY SATISFIED. PROVIDE SCREENING HEDGES FOR | | | ALL GROUND MOUNTED VALVES AND EQUIPMENT AND ADD A NOTE | | | THAT ALL EQUIPMENT | | | WILL BE SCREENED. WATER METER AND BACKFLOW ARE NOT | | | SHOWN ON LANDSCAPE PLANS AS SHOWN ON CIVIL PLANS. | | | RESPONSE: REFER TO GENERAL NOTE #6 ON SHEET L-200. IN | | | ADDITION, SHRUBS AND GROUNDCOVERS HAVE BEEN ADDED | | | AROUND THE ABOVE GROUND UTILITIES TO PROVIDE A SCREEN. | | | 6.2.23 - ZONING REVIEW ON BEHALF OF LANDSCAPE PLANNER: | | | [PARTIALLY SATISFIED] FDC VALVE ON DATURA FRONTAGE/WALL | | | OF LIVE/WORK UNIT IS EXPOSED ON SOUTHERN SIDE, PLEASE | | | INCORPORATE ADDITIONAL HEDGE OR LANDSCAPING TO SCREEN | | | VALVES FROM RIGHT OF WAY. | | | | | | ADDITIONAL COMMENTS 1/4/23: | | | 14. PROVIDE THE LOCATIONS AND DETAIL FOR THE STRUCTURAL | | | SOIL UNDER HARDSCAPE ADJACENT TO THE STREET TREES AS | | | REQUIRED IN 94-113(2). STAFF CAN PROVIDE THE TYPICAL | | | INSTALLATION REQUIREMENTS ON REQUEST. | | | RESPONSE: REFER TO SHEET L-252 AND L-300. | | | 6.2.23 - ZONING REVIEW ON BEHALF OF LANDSCAPE PLANNER: | | | [NOT SATISFIED] ADDITIONAL STRUCTURAL SOIL REQUIRED | | | ALONG DATURA FRONTAGE, SPECIFICALLY UNDERNEATH THE | | | SIDEWALK. | | | | | | 15. PROVIDE THE FLORIDA FRIENDLY LANDSCAPE DESIGN | | | OPTIONS CHART SECTION 94-446 (G) AND PROVIDE THE | | | REQUIRED 50 POINTS. | | | RESPONSE: REFER TO SHEET L-202. | | | 6.2.23 - ZONING REVIEW ON BEHALF OF LANDSCAPE PLANNER: | | | [SATISFIED] | | | | | | 16. PLANT SCHEDULE ON SHEET L-200 DOES NOT MATCH THE | | | PLANT LIST SHOWN ON SHEET L-201. CRAPE MYRTLE AND | | | BRIDAL VEIL TREES ARE NOT CONSISTENT. | | | RESPONSE: PLANT SCHEDULES HAVE BEEN MATCHED. | | | 6.2.23 - ZONING REVIEW ON BEHALF OF LANDSCAPE PLANNER: | | | [SATISFIED] | | | | | | 17. REMOVE EXISTING TREES SHOWN TO REMAIN FROM THE | | | PLANT LIST ON SHEET L-201, AS NO TREES OR PALMS ARE TO | | | REMAIN. | | | RESPONSE: ALL TREES ARE REPRESENTED AS ???TO BE | | | REMOVED??? ON SHEET L-100. | | | 6.2.23 - ZONING REVIEW ON BEHALF OF LANDSCAPE PLANNER: | | | [SATISFIED] | | | | | | 18. THE SIGHT TRIANGLE SHOWN ON SHEET L-200 IS NOT | | | CONSISTENT WITH THE DOWNTOWN REQUIREMENT MEASURED FROM | | | THE BACK OF CURB PER SECTION 94-113 (C). REVISE TO MEET | | | REQUIREMENT. ADDITIONALLY, THE STREET TREES CAN BE | | | PLANTED WITHIN THE SIGHT TRIANGLE, AS THERE WILL BE NO | | | CANOPY LOWER THAN 8 FEET, SO TREES NEED TO BE ADJUSTED | | | TO THE 30 FOOT MAXIMUM SPACING ALONG DATURA ST. | | | RESPONSE: REFER TO SHEET L-200 AND L-300 FOR UPDATED | | | SIGHT TRIANGLES. | | | 6.2.23 - ZONING REVIEW ON BEHALF OF LANDSCAPE PLANNER: | | | [NOT SATISFIED] TRIANGLES SHOULD BE STARTING FROM BACK | | | OF CURB, PLANS SHOW TRIANGLE STARTING FROM INTERIOR TO | | | THE SITE. PLEASE ADJUST. | | | | | | 19. RENDERINGS MUST BE CORRECTED TO ACCURATELY REFLECT | | | THE REQUIRED LANDSCAPING. | | | RESPONSE: REFER TO REVISED RENDERINGS ON SHEETS A600, | | | A601, A602, A603, A604. | | | | | | CONDITIONS OF APPROVAL | | | 1. PRIOR TO THE REMOVAL OR RELOCATION OF ANY TREES ON | | | THE PROPERTY, A TREE ALTERATION PERMIT SHALL BE | | | SUBMITTED, REVIEWED AND APPROVED BY THE DEVELOPMENT | | | SERVICES DEPARTMENT, PLANNING DIVISION. | | | RESPONSE: NOTED | | | 6.2.23 - ZONING REVIEW ON BEHALF OF LANDSCAPE PLANNER: | | | [CONDITIONED] | | | | | | 2. THE APPLICANT, SUCCESSORS AND ASSIGNS SHALL BE | | | RESPONSIBLE FOR THE PERMITTING AND INSTALLATION OF THE | | | STREET TREES AND RIGHT OF WAY LANDSCAPING AND | | | IRRIGATION APPROVED WITH THIS PETITION. | | | RESPONSE: NOTED | | | 6.2.23 - ZONING REVIEW ON BEHALF OF LANDSCAPE PLANNER: | | | [CONDITIONED] | | | | | | 3. THE APPLICANT, SUCCESSORS AND ASSIGNS SHALL BE | | | RESPONSIBLE FOR THE MAINTENANCE OF THE STREET TREES AND | | | RIGHT OF WAY LANDSCAPING AND IRRIGATION. THIS WILL BE | | | THROUGH A SEPARATE MAINTENANCE AGREEMENT WITH THE CITY. | | | RESPONSE: NOTED | | | 6.2.23 - ZONING REVIEW ON BEHALF OF LANDSCAPE PLANNER: | | | [CONDITIONED] | | | |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
2 |
Status |
F |
Date |
01-04-2023 |
|
|
Cont ID |
|
| Sent By |
rcaranci |
Date |
01-04-2023 |
Time |
14:19 |
Rev Time |
0.00 |
| Received By |
rcaranci |
Date |
01-04-2023 |
Time |
14:19 |
Sent To |
|
|
| Notes |
| 2023-01-04 14:20:04 | FROM: RAY CARANCI, SENIOR LANDSCAPE PLANNER | | | 561-822-1462 | | | PROJECT: 120 S DIXIE HWY Z22090015 | | | JANUARY 4, 2022 | | | I HAVE REVIEWED THE ABOVE REFERENCED PETITION, AND | | | PROVIDE THE FOLLOWING COMMENTS: | | | | | | | | | 1. PARTIALLY SATISFIED. PROVIDE THE INDIVIDUAL AND | | | TOTAL CANOPY MITIGATION DUE FOR ALL PROPOSED REMOVALS. | | | TREES PROPOSED TO BE REMOVED WITH A CANOPY DIAMETER OF | | | 20 FEET OR MORE SHOULD HAVE THE MITIGATION SQUARE | | | FOOTAGE CALCULATED BASED ON THE ACTUAL DIAMETER. TREES | | | LESS THAN 20 FEET CANOPY DIAMETER AND PALMS SHOULD SHOW | | | THE CATEGORY MITIGATION DUE. | | | MAKE THE FOLLOWING CORRECTIONS TO THE TREE DISPOSITION | | | LIST SHEET L-: | | | ??? TREES #1, #4, AND #23 ARE 20 FEET OR ABOVE IN | | | CANOPY DIAMETER, SO MUST HAVE THE ACTUAL CANOPY SQUARE | | | FOOTAGE CALCULATED FOR MITIGATION DUE. | | | ??? TREE#4, 21, 22, 23, AND 24 ARE CATEGORY 2 (150 SQ | | | FT EACH EXCEPT #23 AT 314SQ FT)) | | | ??? TREE #9 IS CATEGORY 1 (300 SQ FT) | | | ??? ARECA PALMS DO NOT REQUIRE MITIGATION. (#5, 7, 12, | | | AND 16 NO MITIGATION DUE) | | | ??? #24 DISPOSITION CORRECT TO REMOVE | | | ??? WITH ADJUSTMENTS, TOTAL MITIGATION WAS 7587 SQ FT. | | | ??? ADJUST LIST OF PROVIDED MITIGATION FROM THE PLANT | | | LIST TO IDENTIFY EACH SPECIES AND THE CANOPY CREDIT | | | ASSIGNED TO IT. | | | ??? PROVIDE AN EXPLANATION FOR NOTE #4 REGARDING | | | OFFSITE TREES IN PROXIMITY TO NORTH PROPERTY LINE, AS | | | THERE ARE NO TREES IN THIS AREA. | | | | | | 2. SATISFIED. PER SECTION 94-113 D. ALL STREETSCAPE | | | REQUIREMENTS ARE APPLICABLE TO ANY NEW CONSTRUCTION, | | | RENOVATION OR ADDITION WITH A CONSTRUCTION COST EQUAL | | | OR ABOVE 50% OF THE PROPERTY'S IMPROVEMENT VALUE AS | | | INDICATED BY THE PALM BEACH COUNTY PROPERTY APPRAISER'S | | | OFFICE. EXISTING STREET TREES AND SIDEWALK FOR THIS | | | PROJECT ARE TO BE REMOVED AND REPLACED WITH THE | | | REQUIRED NEW STREET TREES, SIDEWALK, PLANTING BEDS AND | | | STRUCTURAL SOIL. | | | | | | 3. PARTIALLY SATISFIED. THE ON STREET PARKING SHOWN ON | | | S DIXIE ADJACENT TO THE PROJECT IS NOT POSSIBLE WITHIN | | | THE EXISTING SETBACK FROM THE CURB. STREETSCAPE | | | REQUIREMENTS MUST BE MET WITHIN THIS AREA. IF THERE IS | | | NOT SUFFICIENT WIDTH TO PROVIDE THE PLANTING BED, TREE | | | GRATES MAY BE USED IF REQUIRED FOR SIDEWALK TRAVEL | | | WIDTH. | | | | | | THE REQUIRED PLANTING BED WIDTH OF 4 FEET CANNOT BE | | | ACHIEVED ALONG S DIXIE, SO PARTIAL TREE GRATES MAY BE | | | USED TO PROVIDE SPACE FOR THE TREE TO BE PLACED | | | ADEQUATELY AWAY FROM THE CURB. | | | | | | 4. PARTIALLY SATISFIED. PROVIDE CALCULATIONS FOR | | | REQUIRED STREET TREES AT MAXIMUM SPACING EVERY 30 FEET | | | OR PORTION THEREOF FOR EACH STREETSCAPE LENGTH, AND | | | SHOW THE NUMBER PROVIDED PER SECTION 94-113D.2. | | | CODE SECTION REFERENCE HAS NOT BEEN CORRECTED. SOUTH | | | PROPERTY LINE MEASUREMENT OF 245 FEET LENGTH REQUIRES 9 | | | STREET TREES. | | | | | | | | | 5. PARTIALLY SATISFIED. PROVIDE A DIAGRAM OF THE | | | REQUIRED AND PROVIDED PUBLIC AND PRIVATE OPEN SPACE | | | AREAS FOR THE ZONING DISTRICT IN THE SITE AND | | | ARCHITECTURAL DRAWINGS. IDENTIFY THE TYPE OF OPEN SPACE | | | AS ALLOWED BY TABLE IV-7 AND DEFINITIONS IN SECTION | | | 94-109. SHOW HOW THE STANDARDS FOR THE TYPES OF OPEN | | | SPACE ARE MET FOR VEGETATED AREAS AND TREE CANOPY | | | SQUARE FOOTAGE BASED ON TABLE IV-8 ON THE LANDSCAPE | | | PLAN. LANDSCAPE PLANS MUST MATCH THE ARCHITECTURAL | | | PLANS AND CLEARLY IDENTIFY THE OPEN SPACE TYPE THEN | | | DEMONSTRATE HOW THE REQUIREMENTS OF THAT TYPE ARE MET. | | | PROVIDE THE INFORMATION ON THE CODE REQUIREMENT CHART | | | ON SHEET L-201. | | | MAKE THE FOLLOWING CORRECTIONS SHEET A0.03: | | | ??? SHEET A0.03 MUST SHOW HOW THE REQUIRED PRIVATE OPEN | | | SPACE OF 9,810 SQ FT IS PROVIDED BY SHOWING THE | | | PERIMETER OF EACH AREA AND THE TOTAL SQUARE FOOTAGE OF | | | EACH SPACE. | | | ??? ROOFTOP GARDEN IS IDENTIFIED, SO AREA PROVIDED MUST | | | BE SHOWN IN , 30% VEGETATED AREA SHOWN, AND 20% TREE | | | CANOPY SHOWN. | | | ??? PASEO-PASSAGE IS NOT AN OPEN SPACE TYPE. SHOW THE | | | AREA AND ASSIGN AN ALLOWED OPEN SPACE TYPE AND SHOW THE | | | REQUIREMENTS FOR VEGETATED AREA AND TREE CANOPY ARE | | | MET. | | | | | | | | | 6. NOT SATISFIED. REMOVE THE REFERENCE TO SECTION | | | 94-443(D) FROM THE CODE REQUIREMENT CHART AS THIS IS | | | NOT APPLICABLE IN THE DMP. | | | REMOVE THE SECTION FROM THE CHART ON SHEET L-201 AND | | | REPLACE WITH REQUIREMENTS FROM SECTION 94-113 FOR THE | | | STREETSCAPE AND SECTION 94-109 FOR THE OPEN SPACE | | | REQUIREMENTS. | | | | | | | | | 7. PARTIALLY SATISFIED. ALL REQUIRED PUBLIC AND PRIVATE | | | OPEN SPACE TYPES REQUIRING TREE CANOPY MUST SHOW THE | | | TREE CANOPY SQUARE FOOTAGE FOR TREE TYPES BASED ON | | | TABLE IV-8 AND PROVIDE THE TOTAL. | | | TOTALS FOR TREE CANOPY SQUARE FOOTAGE ARE SHOWN ON | | | SHEET A0.03, BUT THE BREAKDOWN OF HOW THAT IS ACHIEVED | | | IS NOT INCLUDED. THIS NEEDS TO BE SHOWN ON SHEET L-210 | | | | | | 8. SATISFIED. ARTIFICIAL TURF AREAS PROPOSED MUST MEET | | | THE REQUIREMENTS OF SECTION 94-451, INCLUDING ALL AREAS | | | THAT ARE ALLOWED BY CODE MUST NOT BE VISIBLE FROM A | | | ROAD OR STREET. | | | | | | | | | 9. ONGOING. EXPLAIN IF THE EXISTING FPL TRANSMISSION | | | LINES WITHIN THE ALLEY WILL STAY IN PLACE OR BE | | | RELOCATED. | | | | | | 10. PARTIALLY SATISFIED. SHOW ALL EXISTING AND PROPOSED | | | WATER AND SEWER AND DRAINAGE LINES ON THE LANDSCAPE | | | PLAN. SHOW LOCATIONS OF BACKFLOWS AND ADJUST LOCATIONS | | | OF UTILITY LINES TO RESOLVE CONFLICTS WITH EXISTING AND | | | PROPOSED TREES AND LANDSCAPING. | | | FIRELINE FROM DATURA ST APPEARS TO BE IN CONFLICT WITH | | | STREET TREE. ADJUST TO AVOID CONFLICT. WATER METER AND | | | BACKFLOW ARE NOT SHOWN ON LANDSCAPE PLANS AS SHOWN ON | | | CIVIL PLANS. | | | | | | | | | 11. SATISFIED. PLANT LIST NEEDS TO BE MODIFIED TO | | | INCLUDE ALL PLANT MATERIAL FOR THE PROJECT, | | | AND SEPARATE PLANT LIST FOR EACH OPEN SPACE AREA | | | PROVIDED FOR REFERENCE TO SHOW COMPLIANCE WITH THE OPEN | | | SPACE TYPE REQUIREMENTS. | | | | | | | | | 12. PARTIALLY SATISFIED. SHOW COMPLIANCE WITH SECTION | | | 94-445 L. PLANT SPECIES. A MINIMUM OF 60 PERCENT OF | | | PLANT MATERIAL ADDED SHALL BE FLORIDA NATIVE OR DROUGHT | | | TOLERANT SPECIES SELECTED FROM THE CITY LIST OR THE | | | LIST OF SPECIES IN THE MOST RECENT EDITION OF SOUTH | | | FLORIDA WATER MANAGEMENT DISTRICT WATERWISE SOUTH | | | FLORIDA LANDSCAPES. PROVIDE THE ACTUAL PERCENTAGE OF | | | NATIVE AND DROUGHT TOLERANT PLANTS ADDED BASED ON THE | | | PLANT LIST. | | | PROVIDE THE TOTAL PLANT MATERIAL ADDED COUNT AND THE | | | TOTAL NUMBER OF PLANTS THAT ARE DROUGHT TOLERANT OR | | | NATIVE THEN SHOW ONE PERCENTAGE. | | | | | | 13. PARTIALLY SATISFIED. PROVIDE SCREENING HEDGES FOR | | | ALL GROUND MOUNTED VALVES AND EQUIPMENT AND ADD A NOTE | | | THAT ALL EQUIPMENT WILL BE SCREENED. | | | WATER METER AND BACKFLOW ARE NOT SHOWN ON LANDSCAPE | | | PLANS AS SHOWN ON CIVIL PLANS. | | | | | | | | | ADDITIONAL COMMENTS 1/4/23: | | | 14. PROVIDE THE LOCATIONS AND DETAIL FOR THE STRUCTURAL | | | SOIL UNDER HARDSCAPE ADJACENT TO THE STREET TREES AS | | | REQUIRED IN 94-113(2). STAFF CAN PROVIDE THE TYPICAL | | | INSTALLATION REQUIREMENTS ON REQUEST. | | | | | | 15. PROVIDE THE FLORIDA FRIENDLY LANDSCAPE DESIGN | | | OPTIONS CHART SECTION 94-446 (G) AND PROVIDE THE | | | REQUIRED 50 POINTS. | | | | | | 16. PLANT SCHEDULE ON SHEET L-200 DOES NOT MATCH THE | | | PLANT LIST SHOWN ON SHEET L-201. CRAPE MYRTLE AND | | | BRIDAL VEIL TREES ARE NOT CONSISTENT. | | | | | | 17. REMOVE EXISTING TREES SHOWN TO REMAIN FROM THE | | | PLANT LIST ON SHEET L-201, AS NO TREES OR PALMS ARE TO | | | REMAIN. | | | | | | 18. THE SIGHT TRIANGLE SHOWN ON SHEET L-200 IS NOT | | | CONSISTENT WITH THE DOWNTOWN REQUIREMENT MEASURED FROM | | | THE BACK OF CURB PER SECTION 94-113 (C). REVISE TO MEET | | | REQUIREMENT. ADDITIONALLY, THE STREET TREES CAN BE | | | PLANTED WITHIN THE SIGHT TRIANGLE, AS THERE WILL BE NO | | | CANOPY LOWER THAN 8 FEET, SO TREES NEED TO BE ADJUSTED | | | TO THE 30 FOOT MAXIMUM SPACING ALONG DATURA ST. | | | | | | 19. RENDERINGS MUST BE CORRECTED TO ACCURATELY REFLECT | | | THE REQUIRED LANDSCAPING. | | | | | | CONDITIONS OF APPROVAL | | | 1. PRIOR TO THE REMOVAL OR RELOCATION OF ANY TREES ON | | | THE PROPERTY, A TREE ALTERATION PERMIT SHALL BE | | | SUBMITTED, REVIEWED AND APPROVED BY THE DEVELOPMENT | | | SERVICES DEPARTMENT, PLANNING DIVISION. | | | 2. THE APPLICANT, SUCCESSORS AND ASSIGNS SHALL BE | | | RESPONSIBLE FOR THE PERMITTING AND INSTALLATION OF THE | | | STREET TREES AND RIGHT OF WAY LANDSCAPING AND | | | IRRIGATION APPROVED WITH THIS PETITION. | | | 3. THE APPLICANT, SUCCESSORS AND ASSIGNS SHALL BE | | | RESPONSIBLE FOR THE MAINTENANCE OF THE STREET TREES AND | | | RIGHT OF WAY LANDSCAPING AND IRRIGATION. THIS WILL BE | | | THROUGH A SEPARATE MAINTENANCE AGREEMENT WITH THE CITY. | | | |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
1 |
Status |
F |
Date |
10-05-2022 |
|
|
Cont ID |
|
| Sent By |
rcaranci |
Date |
10-05-2022 |
Time |
11:24 |
Rev Time |
0.00 |
| Received By |
rcaranci |
Date |
10-05-2022 |
Time |
11:24 |
Sent To |
|
|
| Notes |
| 2022-10-05 11:24:43 | FROM: RAY CARANCI, SENIOR LANDSCAPE PLANNER | | | 561-822-1462 | | | PROJECT: 120 S DIXIE HWY Z22090015 | | | OCTOBER 4, 2022 | | | I HAVE REVIEWED THE ABOVE REFERENCED PETITION, AND | | | PROVIDE THE FOLLOWING COMMENTS: | | | | | | | | | 1. PROVIDE THE INDIVIDUAL AND TOTAL CANOPY MITIGATION | | | DUE FOR ALL PROPOSED REMOVALS. TREES PROPOSED TO BE | | | REMOVED WITH A CANOPY DIAMETER OF 20 FEET OR MORE | | | SHOULD HAVE THE MITIGATION SQUARE FOOTAGE CALCULATED | | | BASED ON THE ACTUAL DIAMETER. TREES LESS THAN 20 FEET | | | CANOPY DIAMETER AND PALMS SHOULD SHOW THE CATEGORY | | | MITIGATION DUE. | | | | | | 2. PER SECTION 94-113 D. ALL STREETSCAPE REQUIREMENTS | | | ARE APPLICABLE TO ANY NEW CONSTRUCTION, RENOVATION OR | | | ADDITION WITH A CONSTRUCTION COST EQUAL OR ABOVE 50% OF | | | THE PROPERTY'S IMPROVEMENT VALUE AS INDICATED BY THE | | | PALM BEACH COUNTY PROPERTY APPRAISER'S OFFICE. EXISTING | | | STREET TREES AND SIDEWALK FOR THIS PROJECT ARE TO BE | | | REMOVED AND REPLACED WITH THE REQUIRED NEW STREET | | | TREES, SIDEWALK, PLANTING BEDS AND STRUCTURAL SOIL. | | | | | | 3. THE ON STREET PARKING SHOWN ON S DIXIE ADJACENT TO | | | THE PROJECT IS NOT POSSIBLE WITHIN THE EXISTING SETBACK | | | FROM THE CURB. STREETSCAPE REQUIREMENTS MUST BE MET | | | WITHIN THIS AREA. IF THERE IS NOT SUFFICIENT WIDTH TO | | | PROVIDE THE PLANTING BED, TREE GRATES MAY BE USED IF | | | REQUIRED FOR SIDEWALK TRAVEL WIDTH. | | | | | | 4. PROVIDE CALCULATIONS FOR REQUIRED STREET TREES AT | | | MAXIMUM SPACING EVERY 30 FEET OR PORTION THEREOF FOR | | | EACH STREETSCAPE LENGTH, AND SHOW THE NUMBER PROVIDED | | | PER SECTION 94-113D.2. | | | | | | | | | 5. PROVIDE A DIAGRAM OF THE REQUIRED AND PROVIDED | | | PUBLIC AND PRIVATE OPEN SPACE AREAS FOR THE ZONING | | | DISTRICT IN THE SITE AND ARCHITECTURAL DRAWINGS. | | | IDENTIFY THE TYPE OF OPEN SPACE AS ALLOWED BY TABLE | | | IV-7 AND DEFINITIONS IN SECTION 94-109. SHOW HOW THE | | | STANDARDS FOR THE TYPES OF OPEN SPACE ARE MET FOR | | | VEGETATED AREAS AND TREE CANOPY SQUARE FOOTAGE BASED ON | | | TABLE IV-8 ON THE LANDSCAPE PLAN. LANDSCAPE PLANS MUST | | | MATCH THE ARCHITECTURAL PLANS AND CLEARLY IDENTIFY THE | | | OPEN SPACE TYPE THEN DEMONSTRATE HOW THE REQUIREMENTS | | | OF THAT TYPE ARE MET. PROVIDE THE INFORMATION ON THE | | | CODE REQUIREMENT CHART ON SHEET L-201. | | | | | | 6. REMOVE THE REFERENCE TO SECTION 94-443(D) FROM THE | | | CODE REQUIREMENT CHART AS THIS IS NOT APPLICABLE IN THE | | | DMP. | | | | | | | | | | | | 7. ALL REQUIRED PUBLIC AND PRIVATE OPEN SPACE TYPES | | | REQUIRING TREE CANOPY MUST SHOW THE TREE CANOPY SQUARE | | | FOOTAGE FOR TREE TYPES BASED ON TABLE IV-8 AND PROVIDE | | | THE TOTAL. | | | | | | 8. ARTIFICIAL TURF AREAS PROPOSED MUST MEET THE | | | REQUIREMENTS OF SECTION 94-451, INCLUDING ALL AREAS | | | THAT ARE ALLOWED BY CODE MUST NOT BE VISIBLE FROM A | | | ROAD OR STREET. | | | | | | | | | 9. EXPLAIN IF THE EXISTING FPL TRANSMISSION LINES | | | WITHIN THE ALLEY WILL STAY IN PLACE OR BE RELOCATED. | | | | | | 10. SHOW ALL EXISTING AND PROPOSED WATER AND SEWER AND | | | DRAINAGE LINES ON THE LANDSCAPE PLAN. SHOW LOCATIONS OF | | | BACKFLOWS AND ADJUST LOCATIONS OF UTILITY LINES TO | | | RESOLVE CONFLICTS WITH EXISTING AND PROPOSED TREES AND | | | LANDSCAPING. | | | | | | 11. PLANT LIST NEEDS TO BE MODIFIED TO INCLUDE ALL | | | PLANT MATERIAL FOR THE PROJECT, | | | AND SEPARATE PLANT LIST FOR EACH OPEN SPACE AREA | | | PROVIDED FOR REFERENCE TO SHOW COMPLIANCE WITH THE OPEN | | | SPACE TYPE REQUIREMENTS. | | | | | | 12. SHOW COMPLIANCE WITH SECTION 94-445 L. PLANT | | | SPECIES. A MINIMUM OF 60 PERCENT OF PLANT MATERIAL | | | ADDED SHALL BE FLORIDA NATIVE OR DROUGHT TOLERANT | | | SPECIES SELECTED FROM THE CITY LIST OR THE LIST OF | | | SPECIES IN THE MOST RECENT EDITION OF SOUTH FLORIDA | | | WATER MANAGEMENT DISTRICT WATERWISE SOUTH FLORIDA | | | LANDSCAPES. PROVIDE THE ACTUAL PERCENTAGE OF NATIVE AND | | | DROUGHT TOLERANT PLANTS ADDED BASED ON THE PLANT LIST. | | | | | | | | | | | | 13. PROVIDE SCREENING HEDGES FOR ALL GROUND MOUNTED | | | VALVES AND EQUIPMENT AND ADD A NOTE THAT ALL EQUIPMENT | | | WILL BE SCREENED. | | | | | | | | | | | | | | | | | | CONDITIONS OF APPROVAL | | | 1. PRIOR TO THE REMOVAL OR RELOCATION OF ANY TREES ON | | | THE PROPERTY, A TREE ALTERATION PERMIT SHALL BE | | | SUBMITTED, REVIEWED AND APPROVED BY THE DEVELOPMENT | | | SERVICES DEPARTMENT, PLANNING DIVISION. | | | 2. THE APPLICANT, SUCCESSORS AND ASSIGNS SHALL BE | | | RESPONSIBLE FOR THE PERMITTING AND INSTALLATION OF THE | | | STREET TREES AND RIGHT OF WAY LANDSCAPING AND | | | IRRIGATION APPROVED WITH THIS PETITION. | | | 3. THE APPLICANT, SUCCESSORS AND ASSIGNS SHALL BE | | | RESPONSIBLE FOR THE MAINTENANCE OF THE STREET TREES AND | | | RIGHT OF WAY LANDSCAPING AND IRRIGATION. THIS WILL BE | | | THROUGH A SEPARATE MAINTENANCE AGREEMENT WITH THE CITY. | | | |
|
|
| Review Stop |
PARK |
PARKING |
| Rev No |
1 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
|
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
POLICE |
POLICE |
| Rev No |
1 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
|
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
PU |
PUBLIC UTILITIES |
| Rev No |
3 |
Status |
F |
Date |
06-23-2023 |
|
|
Cont ID |
|
| Sent By |
relizond |
Date |
06-23-2023 |
Time |
16:17 |
Rev Time |
0.00 |
| Received By |
relizond |
Date |
06-23-2023 |
Time |
16:14 |
Sent To |
|
|
| Notes |
| 2023-06-23 16:17:20 | -8" CLEANOUT REQUIRED FOR 8" LATERAL | | | -NO UTILITY EASEMENT REQUIRED FOR PROPOSED ON-SITE | | | MANHOLE, WILL BE PRIVATELY MAINTAINED | | | -SHOW FULL EXTENTS OF SEWER RUN IN ALLEY | | | -WATER MAIN CONFIGURATION IN ALLEY DOES NOT MATCH CITY | | | RECORDS | | | -CORED MANHOLE WILL REQUIRE REHABBING | | | -PROFILES REQUIRED FOR ALL CONNECTIIONS FROM POINT OF | | | CONNECTION TO POINT OF SERVICE |
|
|
| Review Stop |
PU |
PUBLIC UTILITIES |
| Rev No |
2 |
Status |
|
Date |
01-04-2023 |
|
|
Cont ID |
|
| Sent By |
relizond |
Date |
01-04-2023 |
Time |
13:54 |
Rev Time |
0.00 |
| Received By |
relizond |
Date |
01-04-2023 |
Time |
13:16 |
Sent To |
|
|
| Notes |
| 2023-01-04 13:15:39 | -ADDRESS COMMENTS FROM LAST REVIEW NOTING EVIDENCE OF | | | EXISTING MAIN THAT HAS A PROPOSED TAP | | | -PLEASE READ THROUGH GIVEN CHECKLIST TO ADDRESS | | | STANDARD COMMENTS THAT HAVE NOT BEEN FULFILLED, I.E.: | | | -5 PROVIDE VERTICAL DATUM AND DATUM CONVERSION | | | INFORMATION (NAVD 1988 AND NGVD 1929). | | | -6 SHOW PROJECT ADDRESS ON ALL PLAN SHEETS. | | | -10 PROVIDE CCTV VIDEO AND PIPE RUN REPORT OF EXISTING | | | GRAVITY INFRASTRUCTURES ALONG ENTIRE PROJECT FRONTAGE. | | | (MANHOLE TO MANHOLE) | | | -11 ADD NOTE TO PROVIDE 50 FT. PAVEMENT RESTORATION | | | TRANSITION ON EACH SIDE OF PROPOSED TRENCH IN CITY | | | MAINTAINED ROADWAY AREAS PER CITY OF WPB STANDARD | | | DETAIL GC-8. | | | -PROVIDE PROFILE AND VERTICAL CLEARANCES BETWEEN WATER, | | | SEWER AND STORM LINES PER CITY OF WEST PALM BEACH | | | STANDARD DETAIL GN-2 SERIES, AT ALL UTILITY CROSSINGS. | | | SHOW EXISTING UNDERGROUND UTILITIES ON THE PROFILE TO | | | EASILY DENOTE UTILITY CROSSINGS. THE PROFILE SHOULD | | | SHOW PROPOSED PIPE FROM TIE-IN AT THE MAIN TO POINT OF | | | SERVICE. | | | -SHOW STATIONING AND HORIZONTAL SEPARATION CLEARANCE | | | BETWEEN PROPOSED UTILITIES AND EXISTING UTILITIES | | | AND/OR BASELINE. | | | -LABEL WATER LINES AS PRIVATE WHERE APPLICABLE. | | | -SHOW EXISTING AND PROPOSED DEDICATED UTILITY EASEMENTS | | | TO ALLOW ACCESS FOR CITY PERSONNEL TO PROPOSED UTILITY | | | WATER METERS. VERIFY THAT THERE ARE NO STRUCTURES | | | WITHIN EASEMENT. | | | - SHOW DIRECTION OF FLOW ON PLAN VIEW FOR ALL SANITARY | | | AND STORM SEWERS. | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
PU |
PUBLIC UTILITIES |
| Rev No |
1 |
Status |
F |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
| Received By |
mtechnow |
Date |
10-13-2022 |
Time |
10:51 |
Sent To |
|
|
| Notes |
| 2022-10-13 10:59:21 | -VERIFY THE EXTENT OF THE WM IN THE ALLEY. VERIFY | | | SIZE/TYPE OF MAIN. PER GIS/AS-BUILTS THIS IS SHOWN AS A | | | PRIVATE FIRE LINE. | | | -WILL MOST LIKELY NEED TO RESISE THE WATER CONNECTION | | | ON THE NORTH SIDE. | | | -PLEASE REFER THE CHECKLIST FOR ENGINEERING SUBMITTAL | | | GUIDLINES. | | | | | | CONTACT MICHAEL TECHNOW [email protected] |
|
|
| Review Stop |
PU-CS |
PUBLIC UTILITIES CUSTOMER SRVC |
| Rev No |
4 |
Status |
F |
Date |
06-09-2023 |
|
|
Cont ID |
|
| Sent By |
mhurley |
Date |
06-09-2023 |
Time |
16:49 |
Rev Time |
0.00 |
| Received By |
mhurley |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2023-06-09 16:49:40 | PLEASE PROVIDE WRITTEN RESPONSES TO THE FOLLOWING: | | | -LANDSCAPING PLAN SHOWS CONFLICTS BETWEEN LANDSCAPING | | | AND UTILITIES. IT DOES ALSO NOT SHOW UPDATED UTILITY | | | LOCATIONS. IN RESUBMITTAL PACKAGE, PROVIDE COPY OF | | | LANDSCAPING PLANS WITH UPDATED UTILITY LOCATIONS SHOWN. | | | ENSURE THERE ARE NO CONFLICTS BETWEEN LANDSCAPING AND | | | UTILITIES. (THIS WAS A PRIOR REVIEW COMMENT THAT IS | | | STILL NOT RESOLVED. LANDSCAPE DESIGNER WILL NEED TO | | | REFERENCE CIVIL ENGINEERING PLANS.) | | | RESPECTFULLY, | | | MARK HURLEY [email protected] |
|
|
| Review Stop |
PU-CS |
PUBLIC UTILITIES CUSTOMER SRVC |
| Rev No |
3 |
Status |
F |
Date |
04-05-2023 |
|
|
Cont ID |
|
| Sent By |
mhurley |
Date |
04-05-2023 |
Time |
07:10 |
Rev Time |
0.00 |
| Received By |
mhurley |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2023-04-05 07:09:55 | PLEASE PROVIDE WRITTEN RESPONSE TO THE FOLLOWING: | | | -RESPONSE LETTER SAID WATER DEMAND CALCULATIONS, FDC, | | | UTILITY EASEMENT, AND CLEANOUTS WERE ADDED, BUT CANNOT | | | FIND IN ENGINEERING PLAN SET. ADD TO NEXT RESUBMITTAL. | | | -RESPONSE LETTER SAID WATER SERVICE STANDARD DETAIL WS7 | | | AND WS5 WAS ADDED, BUT CANNOT FIND IN ENGINEERING PLAN | | | SET. ADD TO NEXT RESUBMITTAL. | | | -RESPONSE LETTER SAID ENGINEERING PLANS UPDATED TO SHOW | | | SOUTHEAST DRIVEWAYS ARE BEING REMOVED. PLEASE SHOW THAT | | | MORE CLEARLY ON DEMOLITION AND PGD PLAN SHEETS. | | | -ADD WATER SERVICE STANDARD DETAIL WS2 TO ENGINEERING | | | PLAN SET. | | | -LANDSCAPING PLAN SHOWS CONFLICTS BETWEEN LANDSCAPING | | | AND UTILITIES. IT DOES ALSO NOT SHOW UPDATED UTILITY | | | LOCATIONS. IN RESUBMITTAL PACKAGE, PROVIDE COPY OF | | | LANDSCAPING PLANS WITH UPDATED UTILITY LOCATIONS SHOWN. | | | ENSURE THERE ARE NO CONFLICTS BETWEEN LANDSCAPING AND | | | UTILITIES. | | | -NOTIFY FIRE SYSTEM PLAN DESIGNER THAT FIRE SYSTEM NEAR | | | FIRELINE BACKFLOW ASSEMBLY MUST COMPLY WITH WPB | | | ENGINEERING WATER SERVICE STANDARD DETAIL WS5. THEY | | | NEED TO INCLUDE COPY OF THAT DETAIL IN THEIR PLAN SET | | | AND ENSURE NO GALVANIZED PIPE IS USED UPSTREAM OF | | | FIRELINE BACKFLOW ASSEMBLY. | | | -ARCHITECTURAL AND ENGINEERING PLANS SHOW A | | | MICRO-MOBILITY STATION BUT LANDSCAPING PLANS DO NOT. | | | PLEASE MAKE SURE ALL PLAN SETS ACCURATELY SHOW ANY | | | MICRO-MOBILITY STATIONS. | | | -ON SHEET C2.2, CALLOUT LOCATION OF FIRELINE BACKFLOW | | | ASSEMBLY. | | | RESPECTFULLY, | | | MARK HURLEY [email protected] |
|
|
| Review Stop |
PU-CS |
PUBLIC UTILITIES CUSTOMER SRVC |
| Rev No |
2 |
Status |
F |
Date |
12-13-2022 |
|
|
Cont ID |
|
| Sent By |
mhurley |
Date |
12-13-2022 |
Time |
07:58 |
Rev Time |
0.00 |
| Received By |
mhurley |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2022-12-13 07:58:47 | PLEASE PROVIDE WRITTEN RESPONSES TO THE FOLLOWING: | | | FOLLOWUP COMMENTS: | | | 4. SHOW AND LABEL EXISTING AND PROPOSED FIRE HYDRANTS | | | ON WATER PLAN. RESPONSE: PLEASE REFER TO SHEET A301, | | | THE LOCATION OF THE EXISTING FIRE HYDARNT WAS INCLUDED. | | | NOT SATISIFED ??? INCLUDE UPDATE TO WATER PLAN (CIVIL | | | SET) IN RESUBMITTAL. | | | 5. LARGE METER APPEARS TO BE PROPOSED IN MIDDLE OF | | | WALKING PATH BLOCKING PEDESTRIAN TRAFFIC. COMPARE | | | HARDSCAPE PLAN L300 TO SHEET C2.2. RESPONSE: WILL | | | RESOLVE THIS ISSUE AFTER COORDINATION WITH LANDSCAPE | | | ARCHITECT. | | | NOT SATISIFED ??? RESOLVE IN RESUBMITTAL. | | | 8. LANDSCAPING AND UTILITIES APPEAR TO NOT HAVE | | | SUFFICIENT SEPARATION DISTANCE. SUBMIT SEPARATE | | | LANDSCAPING PLAN SHEET THAT SHOWS DISTANCE BETWEEN | | | UTILITIES AND LANDSCAPING (TREES AND BUSHES). RESPONSE: | | | NOT SATISIFIED ??? NO RESPONSE PROVIDED. | | | 9. SURVEY SHOWS OVERHEAD UTILITY LINE RUNNING ACROSS | | | LOT 13. WHAT WILL HAPPEN TO OVERHEAD UTILITY LINE? | | | RESPONSE: CURRENTLY CONFIRMING LOCATION. | | | NOT SATISIFIED ??? REMINDER TO RESPOND IN RESUBMITTAL. | | | 11. SHOW EXISTING SEWER LATERAL FOR HISTORIC BUILDING | | | ON WASTEWATER PLAN. RESPONSE: CURRENTLY CONFIRMING | | | LOCATION. | | | NOT SATISIFIED ??? INCLUDE UPDATE TO WASTEWATER PLAN IN | | | RESUBMITTAL. | | | 13. DOMESTIC BACKFLOW ASSEMBLY IS EXCESSIVELY FAR FROM | | | METER AND PROPERTY LINE. RELOCATE CLOSER TO METER AND | | | PROPERTY LINE. RESPONSE: NOTED. | | | NOT SATISIFIED ??? THIS REVIEW COMMENT NEEDS CORRECTIVE | | | ACTION OTHER THAN JUST RECOGNITION. | | | 14. SAN MH1 HAS SW INV BUT APPEARS TO BE SE. RESPONSE: | | | NOT SATISIFIED ??? NO RESPONSE PROVIDED. | | | 15. SHOW AND LABEL EXISTING AND PROPOSED CLEANOUTS ON | | | C2.2. RESPONSE: NOTED. | | | NOT SATISIFIED ??? THIS REVIEW COMMENT NEEDS CORRECTIVE | | | ACTION OTHER THAN JUST RECOGNITION. | | | 16. WILL SEWER LATERAL AND PLUMBING PIPE WORK ALRIGHT | | | WITH THE BASEMENT LEVELS? RESPONSE: MEP TO CONFIRM. | | | NOT SATISIFIED ??? PROVIDE MEP CONFIRMATION IN | | | RESUBMITTAL. | | | 18. ADD STANDARD DETAILS WS5 AND WS7 TO ENGINEERING | | | PLAN SET. RESPONSE: NOTED. | | | NOT SATISIFIED ??? WS5 AND WS7 NOT ADDED. | | | 19. ADD WATER AND SEWER DEMAND CALCULATIONS TO SHEET | | | C2.2. RESPONSE: NOTED. | | | NOT SATISFIED ??? WATER AND SEWER DEMAND WERE NOT | | | ADDED. | | | 20. IF FDC ARE NEEDED OR REQUIRED, SHOW ON SHEET C2.2. | | | RESPONSE: NOTED. | | | NOT SATIFIED ??? FDC NOT SHOWN ON C2.2, BUT SEE FDC IN | | | ARCHITECTURAL PLANS. | | | 21. SHOW AND LABEL ANY PROPOSED TRANSFORMER PADS. | | | RESPONSE: CURRENTLY CONFIRMING LOCATION. | | | NOT SATISIFIED ??? SHOW ON CIVIL PLAN RESUBMITTAL. | | | 23. THERE ARE LARGE UTILITY POLES AND OVERHEAD WIRES | | | RUNNING ALONG NORTH PROPERTY LINE. HOW FAR IS BUILDING | | | STRUCTURE SETBACK FROM THOSE? RESPONSE: CURRENTLY | | | CONFIRMING LOCATION. | | | NOT SATISIFIED ??? REMINDER TO INCLUDE IN RESUBMITTAL. | | | 24. SHOW AND LABEL REMOVAL OF EXISTING SOUTHEAST | | | DRIVEWAYS. RESPONSE: NOTED. | | | NOT SATISFIED ??? NOT SHOWN AND LABELED ON CIVIL PLANS. | | | 27. SHOW AND LABEL ANY PROPOSED UTILITY EASEMENTS. DID | | | NOT SEE ONE FOR DOMESTIC WATER METER. RESPONSE: NOTED. | | | WILL SHOW ONCE LOCATION IS CONFIRMED | | | NEW REVIEW COMMENTS: | | | -WPB GIS IS SHOWING EXISTING 6 INCH FIRELINE FOR 324 | | | DATURA ST. NEARBY PROPOSED FIRELINE ON SAME WATER MAIN. | | | SHOW AND LABEL EXISTING FIRELINE ON WATER PLAN (CIVIL). | | | -IS EXISTING 1 STORY BUILDING AT 321 DATURA (LOT 16) | | | PROPOSED TO BE DEMOLISHED? | | | -CALLOUT MINIMUM 18 INCH HORIZONTAL CLEARANCE DISTANCE | | | BETWEEN SAN MH1 AND POTABLE PLUMBING PIPE. | | | -L200 SHOWS TREE TOO CLOSE TO 3 INCH METERED WATER | | | SERVICE. THERE ALSO APPEARS TO BE TREE ON TOP OF SAN | | | MH1. IN ADDITION, THERE IS A TREE PROPOSED ON TOP OF | | | PROPOSED FIRELINE WATER SERVICE. PLEASE PROVIDE | | | HORIZONTAL CLEARANCE DISTANCE BETWEEN TREES AND | | | UTILITIES. | | | -VERIFY NO AUXILIARY WATER SOURCES SUCH AS WELLS WILL | | | BE CONNECTED TO PRIVATE FIRE SYSTEM. | | | -FIRE SYSTEM DESIGN INSIDE BUILDING MUST MEET | | | REQUIREMENTS OF WPB PUBLIC UTILITIES AND ENGINEERING | | | DEPARTMENTS. REFER TO SD WS5 AND CAN CONTACT | | | [email protected] WITH ANY QUESTIONS. | | | RESPECTFULLY, | | | MARK HURLEY [email protected] |
|
|
| Review Stop |
PU-CS |
PUBLIC UTILITIES CUSTOMER SRVC |
| Rev No |
1 |
Status |
F |
Date |
10-04-2022 |
|
|
Cont ID |
|
| Sent By |
mhurley |
Date |
10-04-2022 |
Time |
16:35 |
Rev Time |
0.00 |
| Received By |
mhurley |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2022-10-04 16:35:52 | PLEASE PROVIDE WRITTEN RESPONSES TO THE FOLLOWING: | | | -CANNOT LOCATE PROJECT NARRATIVE AND JUSTIFICATION | | | LETTER IN SUBMITTAL PACKAGE. PLEASE ADD. | | | -SITE PLANS SHOWED BASEMENT LEVELS. DO FERGUSON R TANK | | | SYSTEMS SHOWN ON C2.1 TAKE THAT INTO ACCOUNT? | | | -ONE OF THE WATER MAINS ON C2.2 IS NOT LABELED WITH | | | PIPE SIZE AND MATERIAL TYPE. | | | -SHOW AND LABEL EXISTING AND PROPOSED FIRE HYDRANTS ON | | | WATER PLAN. | | | -LARGE METER APPEARS TO BE PROPOSED IN MIDDLE OF | | | WALKING PATH BLOCKING PEDESTRIAN TRAFFIC. COMPARE | | | HARDSCAPE PLAN L300 TO SHEET C2.2. | | | -GARDEN AREA DESIGN NEAR NORTHEAST CORNER OF HISTORIC | | | BUILDING DOES NOT SEEM CONSISTENT BETWEEN EACH PLAN SET | | | AND AMONG DIFFERENT SHEETS. PLEASE MAKE SURE GENERAL | | | LAYOUT IS THE SAME. | | | -L300 LAYOUT ON EAST SIDE OF HISTORIC BUILDING DOES NOT | | | LOOK SIMILAR TO RENDERINGS A602 AND A603. | | | -LANDSCAPING AND UTILITIES APPEAR TO NOT HAVE | | | SUFFICIENT SEPARATION DISTANCE. SUBMIT SEPARATE | | | LANDSCAPING PLAN SHEET THAT SHOWS DISTANCE BETWEEN | | | UTILITIES AND LANDSCAPING (TREES AND BUSHES). | | | -SURVEY SHOWS OVERHEAD UTILITY LINE RUNNING ACROSS LOT | | | 13. WHAT WILL HAPPEN TO OVERHEAD UTILITY LINE? | | | -ARE ANY CHANGES PROPOSED TO HISTORIC BUILDING? | | | -SHOW EXISTING SEWER LATERAL FOR HISTORIC BUILDING ON | | | WASTEWATER PLAN. | | | -PROPERTY OWNER WOULD BE REQUIRED TO RECORD BACKFLOW | | | COVENANT. | | | -DOMESTIC BACKFLOW ASSEMBLY IS EXCESSIVELY FAR FROM | | | METER AND PROPERTY LINE. RELOCATE CLOSER TO METER AND | | | PROPERTY LINE. | | | -SAN MH1 HAS SW INV BUT APPEARS TO BE SE. | | | -SHOW AND LABEL EXISTING AND PROPOSED CLEANOUTS ON | | | C2.2. | | | -WILL SEWER LATERAL AND PLUMBING PIPE WORK ALRIGHT WITH | | | THE BASEMENT LEVELS? | | | -ALLEY IS LABELED ASPHALT ON CIVIL PLANS BUT SURVEY | | | SHOWS PAVERS. THAT AREA HAD A STREETSCAPE PROJECT | | | WITHIN LAST SEVERAL YEARS. | | | -ADD STANDARD DETAILS WS5 AND WS7 TO ENGINEERING PLAN | | | SET. | | | -ADD WATER AND SEWER DEMAND CALCULATIONS TO SHEET C2.2. | | | -IF FDC ARE NEEDED OR REQUIRED, SHOW ON SHEET C2.2. | | | -SHOW AND LABEL ANY PROPOSED TRANSFORMER PADS. | | | -SHOW AND LABEL ANY OUTSIDE GREASE TRAPS. | | | -THERE ARE LARGE UTILITY POLES AND OVERHEAD WIRES | | | RUNNING ALONG NORTH PROPERTY LINE. HOW FAR IS BUILDING | | | STRUCTURE SETBACK FROM THOSE? | | | -SHOW AND LABEL REMOVAL OF EXISTING SOUTHEAST | | | DRIVEWAYS. | | | -SURVEY NOT SIGNED, SEALED, AND DATED. | | | -SURVEY NOTE 1 SAYS THAT NO SEARCH OF PUBLIC RECORD HAS | | | BEEN MADE AND THERE MAY BE EASEMENTS. VERIFY IF THERE | | | ARE ANY EXISTING EASEMENTS ON SITE. | | | -SHOW AND LABEL ANY PROPOSED UTILITY EASEMENTS. DID NOT | | | SEE ONE FOR DOMESTIC WATER METER. | | | RESPECTFULLY, | | | MARK HURLEY [email protected] |
|
|
| Review Stop |
PW |
PUBLIC WORKS |
| Rev No |
4 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2023-05-23 11:10:46 | NO FURTHER COMMENTS. |
|
|
| Review Stop |
PW |
PUBLIC WORKS |
| Rev No |
3 |
Status |
P |
Date |
03-27-2023 |
|
|
Cont ID |
|
| Sent By |
|
Date |
03-27-2023 |
Time |
|
Rev Time |
0.00 |
| Received By |
|
Date |
03-27-2023 |
Time |
|
Sent To |
|
|
| Notes |
| 2023-03-27 11:42:03 | NO FUTHER COMMENTS. |
|
|
| Review Stop |
PW |
PUBLIC WORKS |
| Rev No |
2 |
Status |
F |
Date |
12-14-2022 |
|
|
Cont ID |
|
| Sent By |
|
Date |
12-14-2022 |
Time |
|
Rev Time |
0.00 |
| Received By |
|
Date |
12-14-2022 |
Time |
|
Sent To |
|
|
| Notes |
| 2022-12-14 15:56:12 | PLEASE IDENTIFY A STAGING AREA TO ROLL OUT THE GARBAGE | | | CONTAINERS, SINCE THE DESIGNATED LOCATION, LOADING | | | ZONE, DOES NOT MEET OUR MINIMUM OPERATIONAL HEIGHT | | | CLEARANCE OF 21 FT. | | | | | | MATT HEJAZI | | | DEPT OF PUBLIC WORKS | | | [email protected] | | | 561-822-2045 |
|
|
| Review Stop |
PW |
PUBLIC WORKS |
| Rev No |
1 |
Status |
F |
Date |
10-05-2022 |
|
|
Cont ID |
|
| Sent By |
|
Date |
10-05-2022 |
Time |
|
Rev Time |
|
| Received By |
|
Date |
10-05-2022 |
Time |
|
Sent To |
|
|
| Notes |
| 2022-10-05 13:40:36 | PLEASE PROVIDE THE FOLLOWINGS: | | | 1- LOS (LEVEL OF SERVICE ANALYSIS) TO REFLECT THE SOLID | | | WASTE VOLUME PRODUCED ALONG WITH THE SIZE, TYPE AND | | | QUANTITY OF THE CONTAINER (I.E. DUMPSTER/COMPACTOR) | | | THAT WILL BE UTILIZED FOR THE SANITATION SERVICE. | | | 2- DETAILS FOR SANITATION SERVICE (I.E. SOLID WASTE | | | CONTAINER(S) TYPE, COLLECTION LOCATION, ETC.). | | | 3- AUTOTURN EXHIBIT WITH DYNAMIC ENVELOPE AND THE | | | VEHICLE'S WHEEL PATH IDENTIFIED WITH DIFFERENT COLORS | | | FOR THE SANITATION SERVICE, FRONT LOADER TRUCK WITH THE | | | FOLLOWING SPECS: | | | - DUAL AXLES | | | - TRUCK LENGTH: 35 FT | | | - TRUCK WIDTH: 11 FT | | | - TURNING RADIUS: | | | - SAE TURNING RADIUS: 32.5 FT | | | - CURB-TO-CURB DIAMETER: 74 FT | | | - WALL-TO-WALL DIAMETER: 86.3 FT | | | 4- DESIGNATED LOCATION FOR THE BULK ITEM PICK UP AND | | | RECYCLING CONTAINERS | | | 5- OWNERS AND/OR OCCUPANTS OF PROPERTY THAT REQUIRE | | | GREASE HAULING SERVICES SHALL ENSURE THAT THEIR GREASE | | | TANKS OR CONTAINERS REMAIN CLEAN, AND ARE ENCLOSED AND | | | NOT IN PUBLIC VIEW. | | | 6- IN CASE OF PROPOSING ADDITION OF ANY NEW CAN(S) IN | | | THE CITY`S RIGHT-OF-WAY , THE LOCATION AND QUANTITY OF | | | THE CAN(S) SHALL BE REVIEWED AND APPROVED BY PUBLIC | | | WORKS DEPARTMENT AND THE CAN(S) SHALL BE TYPE, SIZE AND | | | COLOR APPROVED BY PUBLIC WORKS DEPARTMENT. THE BUILDING | | | MAINTENANCE IS RESPONSIBLE TO MAINTAIN AND SERVICE THE | | | CAN(S). | | | 7- ALL THE PARKING STALL PAINTING SHALL COMPLY WITH THE | | | CITY`S MUNICIPAL CODE SECTION 94-485 AND FLORIDA | | | STATUES [553.5041 F.S.]. | | | 8- SIGNAGE PLAN. ALL STRIPING AND SIGNAGE SHALL COMPLY | | | WITH THE LATEST CITY OF WEST PALM BEACH STANDARD | | | DETAILS AND MEET THE M.U.T.C.D. LATEST EDITION. | | | 9- ALL PAVEMENT MARKING , SIGNING AND SIDEWALK DAMAGED | | | DURING CONSTRUCTION SHALL BE RESTORED. | | | | | | | | | MATT HEJAZI | | | DEPT. OF PUBLIC WORKS | | | [email protected] | | | 561-822-2045 | | | | | | |
|
|
| Review Stop |
STORM |
STORMWATER |
| Rev No |
1 |
Status |
F |
Date |
10-12-2022 |
|
|
Cont ID |
|
| Sent By |
tward |
Date |
10-12-2022 |
Time |
23:56 |
Rev Time |
0.00 |
| Received By |
tward |
Date |
10-12-2022 |
Time |
23:57 |
Sent To |
|
|
| Notes |
| 2022-10-12 23:56:55 | THIS IS A CONCEPTUAL LEVEL REVIEW. CONSTRUCTION LEVEL | | | DETAILS, DESIGN CALCULATIONS AND THE POLLUTION | | | PREVENTION PLAN WILL BE REVIEWED AS PART OF THE | | | ENGINEERING DEVELOPMENT APPROVAL AND BUILDING PERMIT | | | APPLICATION PROCESSES. | | | | | | THE FOLLOWING COMMENTS MUST BE ADDRESSED PRIOR TO SITE | | | PLAN APPROVAL: | | | | | | 1. PROVIDE THE WET SEASON WATER TABLE ELEVATION. | | | | | | 2. PROVIDE THE HEIGHT OF THE STORAGE CHAMBERS AND/OR | | | TOP AND BOTTOM ELEVATIONS. | | | | | | 3. PROVIDE CROSS SECTIONS FOR THE FOLLOWING LOCATIONS. | | | SHOW GRADE BREAKS, EXISTING SURFACES IF NOT BEING | | | RECONSTRUCTED, GENERAL SURFACE SLOPES. LABEL THE NAME | | | OF THE R/W, R/W LINE, DISTANCES FROM R/W TO BACK OF | | | CURB, TO FACE OF BUILDING, TO MAJOR GRADE BREAKS, ETC., | | | FINISHED FLOOR ELEVATION. | | | | | | A. FROM THE CENTERLINE OF DATURA ST. TO 5 FEET PAST THE | | | HIGH POINT OF THE DRIVEWAY. | | | | | | B. FROM THE CENTERLINE OF DATURA ST. TO THE RESIDENTIAL | | | LOBBY DOOR OPENING. | | | | | | C. FROM NORTH SIDE OF THE ALLEY TO THE CENTERLINE OF | | | THE DRIVE AISLE ON THE GROUND FLOOR. | | | | | | | | | 4. REPLACE THE EXISTING DRIVEWAY APRONS AND DROP CURB | | | ALONG DATURA ST. | | | | | | 5. PROVIDE FULL HEIGHT TYPE D CURB ALONG THE DATURA ST. | | | FRONTAGE AND REPLACE THE SIDEWALK WITHIN THE R/W. | | | | | | 6. LABEL ALL UTILITIES (SIZE, MATERIAL). | | | | | | | | | THE FOLLOWING COMMENTS MUST BE ADDRESSED PRIOR TO | | | ISSUANCE OF CONSTRUCTION AUTHORIZATION INCLUDING | | | BUILDING PERMITS AND ENGINEERING DEVELOPMENT APPROVAL. | | | | | | 1. DRAINAGE SYSTEM TO BE DESIGNED TO MEET SFWMD ERP | | | CRITERIA. STORMWATER CALCULATIONS WILL BE REVIEWED WITH | | | THE ENGINEERING PERMIT SUBMITTAL. | | | | | | 2. PROVIDE COPY OF SFWMD ERP PERMIT BEFORE START OF | | | CONSTRUCTION. | | | | | | 3. PROVIDE EROSION AND SEDIMENT CONTROL PLAN WITH THE | | | ENGINEERING PERMIT SUBMITTAL. | | | | | | TRACY WARD, PE | | | SENIOR STORMWATER ENGINEER | | | ENGINEERING SERVICES DEPARTMENT | | | 561-494-1120 (O) | | | [email protected] | | | |
|
|
| Review Stop |
SURVEY |
SURVEYING |
| Rev No |
2 |
Status |
F |
Date |
06-15-2023 |
|
|
Cont ID |
|
| Sent By |
vnoel |
Date |
06-15-2023 |
Time |
07:54 |
Rev Time |
0.00 |
| Received By |
vnoel |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2023-06-15 08:03:00 | 1. A SEPARATE AGREEMENT WILL BE REQUIRED FOR THE | | | EXISTING BUILDING ENCROACHMENT. | | | 2. LEGAL DESCRIPTION DOES NOT APPEAR TO LESS OUT THE | | | EAST 5' OF LOT 11. APPLICANT NEEDS TO DETERMINE | | | OWNERSHIP. | | | 3. REPLAT WILL BE REQUIRED WITH MINOR SUBDIVISION | | | APPLICATION THRU PLANNING. |
|
|
| Review Stop |
SURVEY |
SURVEYING |
| Rev No |
1 |
Status |
F |
Date |
10-11-2022 |
|
|
Cont ID |
|
| Sent By |
vnoel |
Date |
10-11-2022 |
Time |
10:31 |
Rev Time |
|
| Received By |
vnoel |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2022-10-11 10:50:14 | 1. REPLAT WILL BE REQUIRED. | | | 2. BUILDING ENCROACHMENT WILL NEED TO BE ADDRESSED. | | | 3. SUGGEST MOVING WATER METER ASSEMBLY FROM ALLEY TO | | | DATURA. | | | 4. LEGAL DESCRIPTION ON SURVEY HAS THE EAST 23.02' OF | | | THE W 1/2 OF LOT 16 INCLUDED IN PARCEL 4 BUT LESSES AND | | | EXCEPTS IT OUT AT THE END. | | | |
|
|
| Review Stop |
TRAFFIC |
TRAFFIC ENGINEERING |
| Rev No |
4 |
Status |
F |
Date |
06-21-2023 |
|
|
Cont ID |
|
| Sent By |
|
Date |
06-21-2023 |
Time |
|
Rev Time |
0.00 |
| Received By |
|
Date |
06-21-2023 |
Time |
|
Sent To |
|
|
| Notes |
| 2023-06-21 23:59:37 | TRAFFIC COMMENTS | | | 1) SATISFIED. SETUP A METHODOLOGY MEETING | | | 2) SATISFIED. PROVIDE A FULL DETAILED TRAFFIC ANALYSIS. | | | NOTE: THIS SHOULD BE A SEPARATE DOCUMENT FROM THE | | | TRAFFIC IMPACT STATEMENT | | | 3) SATISFIED. PROVIDE LATEST SITE PLAN IN THE ANALYSIS | | | 4) SATISFIED. PROVIDE COUNTY TPS LETTER, ONCE RECEIVED | | | 5) SATISFIED. PROVIDE VALID TRANSPORTATION DEMAND | | | MANAGEMENT (TDM) MEASURES | | | | | | SITE COMMENTS | | | 6) NOT SATISFIED. PROVIDE A TRANSPORTATION SPECIFIC | | | SITE PLAN FOR THE GROUND FLOOR. SHOWCASING | | | TRANSPORTATION RELATED FEATURES (E.G. ROADWAY WIDTHS, | | | DRIVING AISLES, PARKING STALLS, SIDEWALK, CURB, GUTTER, | | | DRIVEWAY, GATES, CROSSWALKS, VISIBILITY TRIANGLE, | | | CORNER & DRIVEWAY SEPARATION DISTANCES, SLOPES, ETC.) | | | PROPERLY LABELED AND DIMENSIONED. SEVERAL DIMENSIONS | | | MISSING IN LATEST RESUBMISSION, PLEASE REMOVE THE TREE | | | CANOPY GRAPHICS. IT IS STRONGLY SUGGESTED TO SETUP A | | | MEETING WITH TRAFFIC ENGINEERING TO CLARIFY CITY | | | EXPECTATIONS ON THIS ITEM. NO RESPONSE PROVIDED IN | | | LATEST RESUBMISSION | | | 7) SATISFIED. IN THE TRANSPORTATION SITE PLAN, PLEASE | | | SHOWCASE BASIC CURB DETAILS (E.G. DRIVEWAY, CURB CUTS, | | | PAVEMENT MARKINGS, PARKING STALLS, ETC.) ON THE | | | OPPOSITE SIDE OF THE ROADS SURROUNDING THE PROPOSED | | | DEVELOPMENT | | | 8) NOT SATISFIED. PROVIDE A SIGNAGE AND PAVEMENT | | | MARKING PLAN. INCLUSIVE OF ALL FEATURES WITHIN THE | | | PROPOSED DEVELOPMENT AND ALONG ALL ROADS FRONTING THE | | | SITE. THIS CAN BE INCLUDED IN THE TRANSPORTATION SITE | | | PLAN. NO RESPONSE PROVIDED IN LATEST RESUBMISSION | | | 9) SATISFIED. PROVIDE AUTOTURN ANALYSIS FOR GARBAGE | | | TRUCK VEHICLES | | | 10) SATISFIED. PROVIDE ENGINEERING REFERENCE AND SPECS | | | SHEETS FOR EACH OF THE PROPOSED TRANSPORTATION FEATURES | | | (E.G. CURB, RAMP, GATE, SIGNAGE, PAVEMENT MARKING, | | | SIGNAL, ETC.) | | | 11) SATISFIED. IDENTIFY AND DESIGNATE AN EASILY | | | ACCESSIBLE MICRO-MOBILITY STATION AREA (MINIMUM 8 X 20 | | | FEET) AND PROVIDE BASIC ELECTRIFICATION READINESS WITH | | | THE FOLLOWING SPECS: A CONDUIT (2-INCH SCHEDULE 40 PVC) | | | TO THE POWER SOURCE WITH AN ELECTRICAL PULL BOX (240V / | | | 10,000W CIRCUIT) | | | 12) SATISFIED. PROVIDE A PARKING TABLE SHOWCASING THE | | | NUMBER OF REQUIRED AND PROVIDED PARKING SPACES, | | | INCLUSIVE OF ADA AND BICYCLE ONES | | | 13) SATISFIED. ARE THERE ANY VEHICULAR GATES PROPOSED | | | WITHIN 20-FEET FROM THE BACK OF THE SIDEWALK? | | | 14) SATISFIED. IS VALET SERVICE PROPOSED? IF SO, | | | PROVIDE AN OPERATIONAL ANALYSIS. DETAILS OF THE | | | ANALYSIS SHOULD BE DISCUSSED DURING THE METHODOLOGY | | | MEETING | | | 15) SATISFIED. EXISTING SIDEWALK ON DATURA IS 10-FEET | | | WIDE, THAT MEASUREMENT SHOULD BE PRESERVED IF NOT | | | EXCEEDED | | | 16) SATISFIED. PER CITY CODE SEC 94-111(Q)(2): | | | NON-PARKING RAMPS SHALL NOT EXCEED 16 PERCENT. IF THE | | | RAMP IS GREATER THAN 14 PERCENT, A BREAK-OVER | | | TRANSITION SHALL BE REQUIRED. THE PREFERRED STANDARD IS | | | TEN PERCENT FOR NON-PARKING RAMP SLOPES. PLEASE PROVIDE | | | SLOPE PERCENTAGES FOR EACH RAMP AND CONFORM TO CODE | | | PERTAINING THE BREAK-OVER TRANSITION | | | 17) SATISFIED. PER CITY CODE SEC 94-111(C)(1): IN THOSE | | | CASES WHERE THE SIDE OF ANY STALL IS ADJACENT TO A | | | WALL, FENCE, BUILDING, OR OTHER PHYSICAL OBSTRUCTION, | | | THE STALL WIDTHS SHALL BE INCREASED BY A MINIMUM OF ONE | | | FOOT. WHERE THERE IS AN OBSTRUCTION ON BOTH SIDES OF | | | THE STALL, THE STALL WIDTHS SHALL BE INCREASED BY A | | | MINIMUM OF TWO FEET. PROVIDE DIMENSIONS FOR EACH | | | PARKING STALL ADJACENT TO A WALL OR OBSTRUCTIONS | | | 18) NOT SATISFIED. PLEASE PROVIDE DETAILS PERTAINING | | | STACKER OPERATIONS. WHO WILL BE USING/ACCESSING THEM | | | AND HOW ARE OPERATIONS CONDUCTED AND MONITORED. NO | | | RESPONSE PROVIDED IN LATEST RESUBMISSION | | | | | | VALERIO ORICCHIO | | | CITY TRANSPORTATION ENGINEER | | | 561-494-1092 | | | [email protected] | | | | | | |
|
|
| Review Stop |
TRAFFIC |
TRAFFIC ENGINEERING |
| Rev No |
3 |
Status |
F |
Date |
04-14-2023 |
|
|
Cont ID |
|
| Sent By |
|
Date |
04-14-2023 |
Time |
|
Rev Time |
0.00 |
| Received By |
|
Date |
04-14-2023 |
Time |
|
Sent To |
|
|
| Notes |
| 2023-04-14 16:52:23 | TRAFFIC COMMENTS | | | 1) SATISFIED. SETUP A METHODOLOGY MEETING | | | 2) SATISFIED. PROVIDE A FULL DETAILED TRAFFIC ANALYSIS. | | | NOTE: THIS SHOULD BE A SEPARATE DOCUMENT FROM THE | | | TRAFFIC IMPACT STATEMENT | | | 3) SATISFIED. PROVIDE LATEST SITE PLAN IN THE ANALYSIS | | | 4) SATISFIED. PROVIDE COUNTY TPS LETTER, ONCE RECEIVED | | | 5) SATISFIED. PROVIDE VALID TRANSPORTATION DEMAND | | | MANAGEMENT (TDM) MEASURES | | | | | | SITE COMMENTS | | | 6) NOT SATISFIED. PROVIDE A TRANSPORTATION SPECIFIC | | | SITE PLAN FOR THE GROUND FLOOR. SHOWCASING | | | TRANSPORTATION RELATED FEATURES (E.G. ROADWAY WIDTHS, | | | DRIVING AISLES, PARKING STALLS, SIDEWALK, CURB, GUTTER, | | | DRIVEWAY, GATES, CROSSWALKS, VISIBILITY TRIANGLE, | | | CORNER & DRIVEWAY SEPARATION DISTANCES, SLOPES, ETC.) | | | PROPERLY LABELED AND DIMENSIONED. SEVERAL DIMENSIONS | | | MISSING IN LATEST RESUBMISSION, PLEASE REMOVE TREE | | | CANOPY GRAPHICS. IT IS STRONGLY SUGGESTED TO SETUP A | | | MEETING WITH TRAFFIC ENGINEERING TO CLARIFY CITY | | | EXPECTATIONS ON THIS ITEM. | | | 7) SATISFIED. IN THE TRANSPORTATION SITE PLAN, PLEASE | | | SHOWCASE BASIC CURB DETAILS (E.G. DRIVEWAY, CURB CUTS, | | | PAVEMENT MARKINGS, PARKING STALLS, ETC.) ON THE | | | OPPOSITE SIDE OF THE ROADS SURROUNDING THE PROPOSED | | | DEVELOPMENT | | | 8) NOT SATISFIED. PROVIDE A SIGNAGE AND PAVEMENT | | | MARKING PLAN. INCLUSIVE OF ALL FEATURES WITHIN THE | | | PROPOSED DEVELOPMENT AND ALONG ALL ROADS FRONTING THE | | | SITE. THIS CAN BE INCLUDED IN THE TRANSPORTATION SITE | | | PLAN | | | 9) SATISFIED. PROVIDE AUTOTURN ANALYSIS FOR GARBAGE | | | TRUCK VEHICLES | | | 10) SATISFIED. PROVIDE ENGINEERING REFERENCE AND SPECS | | | SHEETS FOR EACH OF THE PROPOSED TRANSPORTATION FEATURES | | | (E.G. CURB, RAMP, GATE, SIGNAGE, PAVEMENT MARKING, | | | SIGNAL, ETC.) | | | 11) SATISFIED. IDENTIFY AND DESIGNATE AN EASILY | | | ACCESSIBLE MICRO-MOBILITY STATION AREA (MINIMUM 8 X 20 | | | FEET) AND PROVIDE BASIC ELECTRIFICATION READINESS WITH | | | THE FOLLOWING SPECS: A CONDUIT (2-INCH SCHEDULE 40 PVC) | | | TO THE POWER SOURCE WITH AN ELECTRICAL PULL BOX (240V / | | | 10,000W CIRCUIT) | | | 12) SATISFIED. PROVIDE A PARKING TABLE SHOWCASING THE | | | NUMBER OF REQUIRED AND PROVIDED PARKING SPACES, | | | INCLUSIVE OF ADA AND BICYCLE ONES | | | 13) SATISFIED. ARE THERE ANY VEHICULAR GATES PROPOSED | | | WITHIN 20-FEET FROM THE BACK OF THE SIDEWALK? | | | 14) SATISFIED. IS VALET SERVICE PROPOSED? IF SO, | | | PROVIDE AN OPERATIONAL ANALYSIS. DETAILS OF THE | | | ANALYSIS SHOULD BE DISCUSSED DURING THE METHODOLOGY | | | MEETING | | | 15) SATISFIED. EXISTING SIDEWALK ON DATURA IS 10-FEET | | | WIDE, THAT MEASUREMENT SHOULD BE PRESERVED IF NOT | | | EXCEEDED | | | 16) SATISFIED. PER CITY CODE SEC 94-111(Q)(2): | | | NON-PARKING RAMPS SHALL NOT EXCEED 16 PERCENT. IF THE | | | RAMP IS GREATER THAN 14 PERCENT, A BREAK-OVER | | | TRANSITION SHALL BE REQUIRED. THE PREFERRED STANDARD IS | | | TEN PERCENT FOR NON-PARKING RAMP SLOPES. PLEASE PROVIDE | | | SLOPE PERCENTAGES FOR EACH RAMP AND CONFORM TO CODE | | | PERTAINING THE BREAK-OVER TRANSITION | | | 17) SATISFIED. PER CITY CODE SEC 94-111(C)(1): IN THOSE | | | CASES WHERE THE SIDE OF ANY STALL IS ADJACENT TO A | | | WALL, FENCE, BUILDING, OR OTHER PHYSICAL OBSTRUCTION, | | | THE STALL WIDTHS SHALL BE INCREASED BY A MINIMUM OF ONE | | | FOOT. WHERE THERE IS AN OBSTRUCTION ON BOTH SIDES OF | | | THE STALL, THE STALL WIDTHS SHALL BE INCREASED BY A | | | MINIMUM OF TWO FEET. PROVIDE DIMENSIONS FOR EACH | | | PARKING STALL ADJACENT TO A WALL OR OBSTRUCTIONS | | | 18) PLEASE PROVIDE DETAILS PERTAINING STACKER | | | OPERATIONS. WHO WILL BE USING/ACCESSING THEM AND HOW | | | ARE OPERATIONS CONDUCTED AND MONITORED | | | | | | VALERIO ORICCHIO | | | CITY TRANSPORTATION ENGINEER | | | 561-494-1092 | | | [email protected] | | | |
|
|
| Review Stop |
TRAFFIC |
TRAFFIC ENGINEERING |
| Rev No |
2 |
Status |
F |
Date |
03-15-2023 |
|
|
Cont ID |
|
| Sent By |
|
Date |
03-15-2023 |
Time |
|
Rev Time |
0.00 |
| Received By |
|
Date |
03-15-2023 |
Time |
|
Sent To |
|
|
| Notes |
| 2023-03-15 10:40:32 | TRAFFIC COMMENTS | | | 1) SATISFIED. SETUP A METHODOLOGY MEETING | | | 2) SATISFIED. PROVIDE A FULL DETAILED TRAFFIC ANALYSIS. | | | NOTE: THIS SHOULD BE A SEPARATE DOCUMENT FROM THE | | | TRAFFIC IMPACT STATEMENT | | | 3) SATISFIED. PROVIDE LATEST SITE PLAN IN THE ANALYSIS | | | 4) SATISFIED. PROVIDE COUNTY TPS LETTER, ONCE RECEIVED | | | 5) SATISFIED. PROVIDE VALID TRANSPORTATION DEMAND | | | MANAGEMENT (TDM) MEASURES | | | SITE COMMENTS | | | 6) NOT SATISFIED. PROVIDE A TRANSPORTATION SPECIFIC | | | SITE PLAN FOR THE GROUND FLOOR. SHOWCASING | | | TRANSPORTATION RELATED FEATURES (E.G. ROADWAY WIDTHS, | | | DRIVING AISLES, PARKING STALLS, SIDEWALK, CURB, GUTTER, | | | DRIVEWAY, GATES, CROSSWALKS, VISIBILITY TRIANGLE, | | | CORNER & DRIVEWAY SEPARATION DISTANCES, SLOPES, ETC.) | | | PROPERLY LABELED AND DIMENSIONED. SEVERAL DIMENSIONS | | | MISSING IN LATEST RESUBMISSION, PLEASE REMOVE TREE | | | CANOPY GRAPHICS | | | 7) SATISFIED. IN THE TRANSPORTATION SITE PLAN, PLEASE | | | SHOWCASE BASIC CURB DETAILS (E.G. DRIVEWAY, CURB CUTS, | | | PAVEMENT MARKINGS, PARKING STALLS, ETC.) ON THE | | | OPPOSITE SIDE OF THE ROADS SURROUNDING THE PROPOSED | | | DEVELOPMENT | | | 8) NOT SATISFIED. PROVIDE A SIGNAGE AND PAVEMENT | | | MARKING PLAN. INCLUSIVE OF ALL FEATURES WITHIN THE | | | PROPOSED DEVELOPMENT AND ALONG ALL ROADS FRONTING THE | | | SITE. THIS CAN BE INCLUDED IN THE TRANSPORTATION SITE | | | PLAN | | | 9) SATISFIED. PROVIDE AUTOTURN ANALYSIS FOR GARBAGE | | | TRUCK VEHICLES | | | 10) SATISFIED. PROVIDE ENGINEERING REFERENCE AND SPECS | | | SHEETS FOR EACH OF THE PROPOSED TRANSPORTATION FEATURES | | | (E.G. CURB, RAMP, GATE, SIGNAGE, PAVEMENT MARKING, | | | SIGNAL, ETC.) | | | 11) SATISFIED. IDENTIFY AND DESIGNATE AN EASILY | | | ACCESSIBLE MICRO-MOBILITY STATION AREA (MINIMUM 8 X 20 | | | FEET) AND PROVIDE BASIC ELECTRIFICATION READINESS WITH | | | THE FOLLOWING SPECS: A CONDUIT (2-INCH SCHEDULE 40 PVC) | | | TO THE POWER SOURCE WITH AN ELECTRICAL PULL BOX (240V / | | | 10,000W CIRCUIT) | | | 12) SATISFIED. PROVIDE A PARKING TABLE SHOWCASING THE | | | NUMBER OF REQUIRED AND PROVIDED PARKING SPACES, | | | INCLUSIVE OF ADA AND BICYCLE ONES | | | 13) SATISFIED. ARE THERE ANY VEHICULAR GATES PROPOSED | | | WITHIN 20-FEET FROM THE BACK OF THE SIDEWALK? | | | 14) SATISFIED. IS VALET SERVICE PROPOSED? IF SO, | | | PROVIDE AN OPERATIONAL ANALYSIS. DETAILS OF THE | | | ANALYSIS SHOULD BE DISCUSSED DURING THE METHODOLOGY | | | MEETING | | | 15) SATISFIED. EXISTING SIDEWALK ON DATURA IS 10-FEET | | | WIDE, THAT MEASUREMENT SHOULD BE PRESERVED IF NOT | | | EXCEEDED | | | 16) SATISFIED. PER CITY CODE SEC 94-111(Q)(2): | | | NON-PARKING RAMPS SHALL NOT EXCEED 16 PERCENT. IF THE | | | RAMP IS GREATER THAN 14 PERCENT, A BREAK-OVER | | | TRANSITION SHALL BE REQUIRED. THE PREFERRED STANDARD IS | | | TEN PERCENT FOR NON-PARKING RAMP SLOPES. PLEASE PROVIDE | | | SLOPE PERCENTAGES FOR EACH RAMP AND CONFORM TO CODE | | | PERTAINING THE BREAK-OVER TRANSITION | | | 17) SATISFIED. PER CITY CODE SEC 94-111(C)(1): IN THOSE | | | CASES WHERE THE SIDE OF ANY STALL IS ADJACENT TO A | | | WALL, FENCE, BUILDING, OR OTHER PHYSICAL OBSTRUCTION, | | | THE STALL WIDTHS SHALL BE INCREASED BY A MINIMUM OF ONE | | | FOOT. WHERE THERE IS AN OBSTRUCTION ON BOTH SIDES OF | | | THE STALL, THE STALL WIDTHS SHALL BE INCREASED BY A | | | MINIMUM OF TWO FEET. PROVIDE DIMENSIONS FOR EACH | | | PARKING STALL ADJACENT TO A WALL OR OBSTRUCTIONS | | | | | | VALERIO ORICCHIO | | | CITY TRANSPORTATION ENGINEER | | | 561-494-1092 | | | [email protected] | | | |
|
|
| Review Stop |
TRAFFIC |
TRAFFIC ENGINEERING |
| Rev No |
1 |
Status |
F |
Date |
10-13-2022 |
|
|
Cont ID |
|
| Sent By |
|
Date |
10-13-2022 |
Time |
|
Rev Time |
|
| Received By |
|
Date |
10-13-2022 |
Time |
|
Sent To |
|
|
| Notes |
| 2022-10-13 04:06:28 | TRAFFIC COMMENTS | | | 1) SETUP A METHODOLOGY MEETING | | | 2) PROVIDE A FULL DETAILED TRAFFIC ANALYSIS. NOTE: THIS | | | SHOULD BE A SEPARATE DOCUMENT FROM THE TRAFFIC IMPACT | | | STATEMENT | | | 3) PROVIDE LATEST SITE PLAN IN THE ANALYSIS | | | 4) PROVIDE COUNTY TPS LETTER, ONCE RECEIVED | | | 5) PROVIDE VALID TRANSPORTATION DEMAND MANAGEMENT (TDM) | | | MEASURES | | | SITE COMMENTS | | | 6) PROVIDE A TRANSPORTATION SPECIFIC SITE PLAN FOR THE | | | GROUND FLOOR. SHOWCASING TRANSPORTATION RELATED | | | FEATURES (E.G. ROADWAY WIDTHS, DRIVING AISLES, PARKING | | | STALLS, SIDEWALK, CURB, GUTTER, DRIVEWAY, GATES, | | | CROSSWALKS, VISIBILITY TRIANGLE, CORNER & DRIVEWAY | | | SEPARATION DISTANCES, SLOPES, ETC.) PROPERLY LABELED | | | AND DIMENSIONED | | | 7) IN THE TRANSPORTATION SITE PLAN, PLEASE SHOWCASE | | | BASIC CURB DETAILS (E.G. DRIVEWAY, CURB CUTS, PAVEMENT | | | MARKINGS, PARKING STALLS, ETC.) ON THE OPPOSITE SIDE OF | | | THE ROADS SURROUNDING THE PROPOSED DEVELOPMENT | | | 8) PROVIDE A SIGNAGE AND PAVEMENT MARKING PLAN. | | | INCLUSIVE OF ALL FEATURES WITHIN THE PROPOSED | | | DEVELOPMENT AND ALONG ALL ROADS FRONTING THE SITE | | | 9) PROVIDE AUTOTURN ANALYSIS FOR GARBAGE TRUCK VEHICLES | | | 10) PROVIDE ENGINEERING REFERENCE AND SPECS SHEETS FOR | | | EACH OF THE PROPOSED TRANSPORTATION FEATURES (E.G. | | | CURB, RAMP, GATE, SIGNAGE, PAVEMENT MARKING, SIGNAL, | | | ETC.) | | | 11) IDENTIFY AND DESIGNATE AN EASILY ACCESSIBLE | | | MICRO-MOBILITY STATION AREA (MINIMUM 8 X 20 FEET) AND | | | PROVIDE BASIC ELECTRIFICATION READINESS WITH THE | | | FOLLOWING SPECS: A CONDUIT (2-INCH SCHEDULE 40 PVC) TO | | | THE POWER SOURCE WITH AN ELECTRICAL PULL BOX (240V / | | | 10,000W CIRCUIT) | | | 12) PROVIDE A PARKING TABLE SHOWCASING THE NUMBER OF | | | REQUIRED AND PROVIDED PARKING SPACES, INCLUSIVE OF ADA | | | AND BICYCLE ONES | | | 13) ARE THERE ANY VEHICULAR GATES PROPOSED WITHIN | | | 20-FEET FROM THE BACK OF THE SIDEWALK? | | | 14) IS VALET SERVICE PROPOSED? IF SO, PROVIDE AN | | | OPERATIONAL ANALYSIS. DETAILS OF THE ANALYSIS SHOULD BE | | | DISCUSSED DURING THE METHODOLOGY MEETING | | | 15) EXISTING SIDEWALK ON DATURA IS 10-FEET WIDE, THAT | | | MEASUREMENT SHOULD BE PRESERVED IF NOT EXCEEDED | | | 16) PER CITY CODE SEC 94-111(Q)(2): NON-PARKING RAMPS | | | SHALL NOT EXCEED 16 PERCENT. IF THE RAMP IS GREATER | | | THAN 14 PERCENT, A BREAK-OVER TRANSITION SHALL BE | | | REQUIRED. THE PREFERRED STANDARD IS TEN PERCENT FOR | | | NON-PARKING RAMP SLOPES. PLEASE PROVIDE SLOPE | | | PERCENTAGES FOR EACH RAMP AND CONFORM TO CODE | | | PERTAINING THE BREAK-OVER TRANSITION | | | 17) PER CITY CODE SEC 94-111(C)(1): IN THOSE CASES | | | WHERE THE SIDE OF ANY STALL IS ADJACENT TO A WALL, | | | FENCE, BUILDING, OR OTHER PHYSICAL OBSTRUCTION, THE | | | STALL WIDTHS SHALL BE INCREASED BY A MINIMUM OF ONE | | | FOOT. WHERE THERE IS AN OBSTRUCTION ON BOTH SIDES OF | | | THE STALL, THE STALL WIDTHS SHALL BE INCREASED BY A | | | MINIMUM OF TWO FEET. PROVIDE DIMENSIONS FOR EACH | | | PARKING STALL ADJACENT TO A WALL OR OBSTRUCTIONS | | | | | | VALERIO ORICCHIO | | | CITY TRANSPORTATION ENGINEER | | | 561-494-1092 | | | [email protected] | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
5 |
Status |
F |
Date |
07-10-2023 |
|
|
Cont ID |
|
| Sent By |
ckimmerl |
Date |
07-10-2023 |
Time |
15:54 |
Rev Time |
0.00 |
| Received By |
ckimmerl |
Date |
06-16-2023 |
Time |
13:44 |
Sent To |
|
|
| Notes |
| 2023-06-16 13:46:40 | 06/07/2023 | | | | | | 1. ZONING REVIEW 4.20.23 [NOT SATISFIED] | | | | | | TABLE ON SHEET A1.00 STILL APPEARS TO HAVE | | | DISCREPANCIES: | | | RESIDENTIAL PARKING MIN: 1SPACE/UNIT & 1SPACE/20UNIT | | | FOR GUEST 87 | | | REGULAR UNITS = 87 SPACES + 5 SPACES FOR GUEST = 92 | | | REQUIRED SPACES RESPONSE: REGULAR UNITS = 65 SPACES + 4 | | | GUEST = 69 REQUIRED SPACES | | | PLEASE REFER TO SHEET A.100 FOR REVISED PARKING DATA | | | AND UNIT COUNT DATA. | | | | | | [ZONING REVIEW 5.23.23] SATISFIED ??? 69 SPACES; FOR 65 | | | UNITS AND 4 GUESTS | | | | | | 72 MICRO UNITS PROPOSED | | | DOES NOT REQUIRE PARKING MAX. PERMITTED: 0.5 | | | SPACES/UNIT + 1SPACE/20UNIT | | | FOR GUEST | | | RESPONSE: 94 MICROUNITS DOES NOT REQUIRE PARKING. | | | PLEASE REFER TO SHEET A.100 FOR REVISED PARKING DATA | | | AND UNIT COUNT DATA. | | | | | | [ZONING REVIEW 5.23.23] SATISFIED ??? NO SPACES | | | PROVIDED FOR MICROUNITS | | | | | | LIVE/WORK PARKING MIN: 2 SPACES/1000SF | | | 4,464 SF OF LIVE/WORK ON GROUND FLOOR (6 UNITS AT 744 | | | EACH PER SHEET A3.01) | | | = 10 SPACES | | | 92 RES/GUEST + 10 LIVE/WORK = 102 REQUIRED PARKING | | | SPOTS NOT 130 | | | 69 RES/GUEST +10 LIVE/WORK = 79 REQUIRED PARKING SPOTS | | | PLEASE REFER TO REVISED SHEET A.100 FOR REVISED PARKING | | | DATA. | | | | | | [ZONING REVIEW 5.23.23] NOT SATISFIED ??? 6,678 SF OF | | | LIVEWORK ACCORDING TO A1.00 AND A0.04, REQUIRES A | | | MINIMUM OF 13 SPACES; ONLY PROVIDING 10. PLEASE PROVIDE | | | THE ADDITIONAL 3 SPACES. | | | | | | RESPONSE: 5814 SF OF LIVE/WORK = 12 PARKING SPACES | | | | | | PLEASE REFER TO SHEET A1.00 FOR REVISED PARKING | | | CALCULATIONS. | | | [ZONING REVIEW 6.13.23] SATISFIED | | | | | | HOWEVER, NOW THAT THE HISTORIC BUILDING AND ITS USES | | | ARE INCORPORATED INTO THE PROJECT SITE, PLEASE PROVIDE | | | USE/SQUAREFOOTAGE BREAKDOWN OF INTERIOR TENANTS, SO | | | THAT THESE USES CAN BE APPROPRIATELY PARKED. | | | | | | 5,750+5,778 SF = 11,528 SF OF POTENTIAL RETAIL OR | | | OFFICE USES THAT NEED PARKING. | | | RESPONSE: RETAIL / OFFICES PARKING = 23 P.S FOR A TOTAL | | | OF 102 P.S IN THE BUILDING. | | | PLEASE REFER TO SHEET A.100 FOR REVISED PARKING | | | [ZONING REVIEW 5.23.23] PARTIALLY SATISFIED ??? CLARIFY | | | THE USE WITHIN THE HISTORIC BUILDING. IF SF IS ALL | | | RETAIL/COMMERCIAL USE IT CAN BE PARKED AT A MINIMUM OF | | | 2 SPACES/1000SF. THEN THE PROPOSED 23 SPACES IS | | | SUFFICIENT. | | | IF SF IS ALL OFFICE USES IT CAN BE PARKED AT A MINIMUM | | | OF 2.5 SPACES/1000SF. WOULD REQUIRE 29 SPACES. | | | | | | RESPONSE: HISTORIC BUILDING IS RETAIL/COMMERCIAL SO WE | | | WILL HAVE 23 PARKING SPACES PROVIDED . | | | PLEASE REFER TO SHEET A1.00 FOR REVISED PARKING | | | CALCULATIONS. | | | [ZONING REVIEW 6.13.23] SATISFIED | | | | | | PLEASE CLARIFY THE 8 GUEST SPACES, 12 LIVE/WORK SPACES, | | | AND 23 COMMERCIAL SPACES CALCULATIONS AS SHOWN IN | | | TABLE. | | | RESPONSE: PARKING HAVE BEEN REVISED PLEASE REFER TO | | | SHEET A.100 THE BUILDING HAS 4 GUEST SPACES, 10 | | | LIVE/WORKSPACES, 23 COMMERCIAL/OFFICES SPACES AND 65 | | | RESIDENTIAL SPACES FOR A TOTAL OF 102 P.S. | | | [ZONING REVIEW 5.23.23] NOT SATISFIED ??? MINIMUM | | | REQUIRED PARKING IS 105 SPACES IF HISTORIC BUILDING IS | | | ALL RETAIL/COMMERCIAL. | | | | | | MINIMUM REQUIRED PARKING IS 111 SPACES IF HISTORIC | | | BUILDING IS ALL OFFICE. | | | | | | RESPONSE: HISTORIC BUILDING IS RETAIL/COMMERCIAL SO WE | | | WILL HAVE 104 PARKING SPACES IN TOTAL. | | | | | | PLEASE REFER TO SHEET A1.00 FOR REVISED PARKING | | | CALCULATIONS. | | | [ZONING REVIEW 6.13.23] SATISFIED | | | | | | PLEASE CLARIFY IF YOU ARE PROVIDING PARKING FOR ANY OF | | | THE MICRO-UNITS. | | | BICYCLE PARKING IS REQUIRED. | | | - 1 BICYCLE SPACE PER EVERY 15 PARKING SPACES (SHALL BE | | | WITHIN SECURED/COVERED ROOM). | | | MICRO-UNITS DOES NOT REQUIRED PARKING 7 BIKE SPACES | | | REQUIRED PROVIDED ON BASEMENT. | | | PLEASE REFER TO REVISED SHEET A1.00 SHOWING REQUIRED | | | BIKE SPACES. | | | [ZONING REVIEW 5.23.23] SATISFIED ??? 57 BIKE SPACES; 7 | | | BIKE SPACES FOR REQ. PARKING, 3 SPACES FOR FRONTAGE, 47 | | | SPACES FOR 94 MICRO UNITS. | | | | | | - 1 BIKE SPACE PER 100 LINEAR FEET OF FRONTAGE. | | | RESPONSE: PLEASE REFER TO REVISED SHEET A1.00 SHOWING | | | REQUIRED BIKE SPACES CALCULATION. | | | [ZONING REVIEW 5.23.23] SATISFIED | | | | | | - WITH INCLUSION OF MICRO-UNITS ALSO NEED 0.5 BIKE | | | SPACES PER MICRO-UNIT. RESPONSE: PLEASE REFER TO | | | REVISED SHEET A.100 SHOWING BIKE SPACES CALCULATION. 47 | | | BIKE SPACES NEEDED FOR MICRONUNITS. | | | [ZONING REVIEW 5.23.23] SATISFIED | | | | | | - A BIKESHARING STATION IS ALSO REQUIRED ONSITE, PLEASE | | | CONTACT COLBY REESE 305-733-9650 [email protected] FOR | | | DIMENSIONS OF THE CITY???S BRIGHTBIKE STATIONS. | | | MICRO-MOBILITY STATION CANNOT BE LOCATED WITHIN | | | REQUIRED LANDSCAPE STRIP ALONG DATURA FRONTAGE. | | | RESPONSE: PLEASE REFER TO SHEET A3.00 BIKE RACK HAS | | | BEEN LOCATED. | | | [ZONING REVIEW 5.23.23] NOT SATISFIED ??? PLEASE | | | PROVIDE CORRESPONDENCE WITH CITY BIKESHARE OPERATOR OR | | | BRIGHTBIKE REP. COLBY REESE 305-733-9650 | | | [email protected]. | | | A STATION MAY BE REQUIRED ALONG PROJECT FRONTAGE OR | | | ALONG ROW. PROPOSED LOCATION ON A3.00 IS WITHIN | | | BASEMENT. PROJECT IS LOCATED WITHIN 500 FT. OF TWO | | | SEPARATE STATIONS WITHIN THE CITY, REQUIREMENT MAY BE | | | WAIVED. | | | | | | UPDATE: 5.31.23 PER DISCUSSION BETWEEN APPLICANT AND | | | COLBY, STATION IS NOT REQUIRED. [PARTIALLY SATISFIED] | | | PLEASE REMOVE MICRO-MOBILITY STATION FROM PLANS. | | | | | | RESPONSE:MICRO-MOBILITY STATION HAS BEEN REMOVED FROM | | | PLANS. | | | PLEASE REFER TO REVISED SHEET A3.01 AND A2.00 | | | [ZONING REVIEW 6.13.23] SATISFIED | | | | | | | | | - A PROJECT WITH RESIDENTIAL MICRO-UNITS SHALL PROVIDE | | | ON-SITE CAR- SHARE STATIONS ON A RATIO OF ONE PER EVERY | | | 13 UNITS. THE TOTAL AMOUNT OF CAR-SHARE STATIONS MAY BE | | | REDUCED BY ONE CAR-SHARE STATION PER EVERY 13 ON-SITE | | | PARKING SPACES PROVIDED. THE TOTAL NUMBER OF CAR- | | | SHARE STATIONS MAY BE ADJUSTED BASED ON CURRENT SYSTEM | | | DEMANDS, BUT A MINIMUM OF ONE CAR-SHARE STATION SHALL | | | BE PROVIDED. THE REMAINDER OF THE SPACES SHALL BE | | | RESERVED FOR FUTURE SERVICE EXPANSION. | | | 8 CAR STATION PROVIDED.PLEASE REFER TO REVISED SHEET | | | A3.00 FOR CAR-SHARE STATION LOCATION. | | | [ZONING REVIEW 5.23.23] NOT SATISFIED ??? PLEASE LABEL | | | OR INDICATE WHICH SPACES ARE FOR CAR-SHARE, A3.00 DOES | | | NOT APPEAR TO HIGHLIGHT THESE SPACES. | | | | | | RESPONSE: CAR SHARE SPACES ARE LABELED. | | | PLEASE REFER TO REVISED SHEET A3.00 | | | [ZONING REVIEW 6.13.23] SATISFIED | | | | | | | | | - A PROJECT WITH RESIDENTIAL MICRO-UNITS SHALL | | | CONTRIBUTE A TROLLEY FEE PER UNIT PER MONTH TO SUPPORT | | | THE OPERATION OF THE CITY'S TROLLEY | | | SYSTEM, AS ESTABLISHED BY RESOLUTION OF THE CITY | | | COMMISSION FROM TIME TO TIME. | | | RESPONSE: ACKNOWLEDGED. PLEASE ADVISE TO THE AMOUNTS, | | | PROCESS AND TIMING AS REQUIRED PER THE CITY | | | REGULATIONS. | | | [ZONING REVIEW 5.23.23] SATISFIED ??? PER RESOLUTION | | | NO. 211-17 ??????A TROLLEY FEE OF $10.00 PER UNIT PER | | | MONTH, FOR THE LIFE OF THE PROJECT, AT THE RATE | | | ESTABLISHED BY RESOLUTION 211-17 OR AS AMENDED BY THE | | | CITY COMMISSION. THE FIRST PAYMENT SHALL BE COMPLETED | | | AT THE TIME OF PROJECT CO.??? | | | [ZONING REVIEW 6.13.23] SATISFIED | | | | | | | | | 2. ZONING REVIEW 4.20.23 [NOT SATISFIED] | | | | | | WITHIN CWD 10-12 DISTRICT, THE PODIUM GOES UP TO LEVEL | | | 5. SUBMITTED PLANS ARE ONLY SHOWING PLANAR BREAKS FOR | | | GROUND FLOOR. SIMILAR TO SHEET A0.5.5 PLEASE SHOW | | | PLANER BREAKS FOR FLOORS 2-5 ALONG THE DATURA FRONTAGE. | | | PLEASE ADJUST THE CALCULATIONS AND AREA SHADED TO COUNT | | | ONLY THE PORTIONS WHERE THE PRIMARY FACE OR PLANE OF | | | THE BUILDING IS | | | INTERRUPTED BY A 3 FT. + PROJECTION OR RECESSED AREA. | | | PLEASE PROVIDE THE DIMENSION OF THE DEPTH OF THE RECESS | | | OR PROJECTION AS WELL. SHEET A0.5.6 | | | AND A0.5.7 IS NOT NEEDED OR CALCULATIONS DO NOT NEED TO | | | BE PROVIDED; AS PLANAR BREAKS ARE ONLY FOR BUILDING | | | FRONTAGES LONGER THAN 150 FT. AND ON STREETS; IN THIS | | | CASE ONLY THE DATURA FRONTAGE. BECAUSE THE HISTORIC | | | BUILDING ALONG DIXIE ALREADY PROVIDES A BREAK IN THE | | | MASS AND IS ONLY 141-3 IN WIDTH. | | | RESPONSE: PLEASE REFER TO SHEET A0.5.6 SHOWING PLANAR | | | BREAKS FOR FLOORS 2-5 ALONG THE DATURA FRONTAGE. | | | | | | [ZONING REVIEW 5.23.23] PARTIALLY SATISFIED. TYPICALLY | | | ENTRYWAYS AND BALCONY PROJECTIONS OR RECESSED AREAS | | | WOULD NOT COUNT TOWARD PLANAR BREAK REQUIREMENTS. STAFF | | | ENCOURAGES ALTERNATIVE PLANAR BREAK PROPOSAL FOR FLOORS | | | 1-5 (PODIUM), PERHAPS WITHIN THE VERTICAL ELEMENTS | | | BETWEEN BALCONIES. HOWEVER, STAFF IS AMENABLE TO | | | INTERPRETING BALCONY AS PLANAR BREAK UNDER THE | | | CONDITION THAT GLASS OR TRANSPARENT RAILING MATERIALS | | | ARE UTILIZED, AS IS SHOWN IN THE RENDERS. CONDITION OF | | | DAC OR SITE PLAN APPROVAL. | | | | | | RESPONSE: PLANAR BREAK PROPOSAL WAS APPLIED TO | | | ELEVATION AS DISCUSSED WITH CHRIS KIMMERLY FROM THE | | | CITY. PLEASE REFER TO REVISED SHEETS A4.02, A4.03 | | | [ZONING REVIEW 6.13.23] STAFF TO CONDITION AS PART OF | | | DAC APPROVAL AND/OR SITE PLAN APPROVAL. | | | | | | 3. ZONING REVIEW 4.20.23 [NOT SATISFIED] | | | PLEASE REVISE SHEET A0.03 AND L-203 MINOR TEXT | | | CORRECTION, OVERHEAD | | | COVER IS NOT REQUIRED, IT IS JUST PERMITTED UP TO A | | | MAXIMUM PERCENTAGE | | | OF THE SPACE. WITHIN THE ROOFTOP GARDEN CALCULATIONS | | | IT???S NOTED | | | | | | ???REQUIRED 30%???. PRIVATE OPEN SPACE ON GROUND FLOOR | | | (GARDEN) IS NOT NEEDED AS THE REQUIREMENT IS MET WITH | | | ROOFTOP GARDEN. ALSO IF PRIVATE OPEN SPACE IS LOCATED | | | ON GROUND FLOOR, IT MUST BE DESIGNED TO MEET PUBLIC | | | OPEN SPACE REQUIREMENTS AND BE ACCESSIBLE TO THE | | | PUBLIC. RECOMMEND REMOVING REFERENCE TO GROUND FLOOR | | | PRIVATE SPACE. SATISFIED REQUIREMENT WITH ROOFTOP | | | SPACE. | | | RESPONSE: PLEASE REFER TO SHEET A0.03 FOR REVISED NOTE | | | AND GROUND FLOOR REFERENCE HAS BEEN REMOVED. | | | [ZONING REVIEW 5.23.23] SATISFIED | | | | | | 4. ZONING REVIEW 4.20.23 [SATISFIED] RESPONSE: | | | ACKNOWLEDGED. | | | | | | 5. ZONING REVIEW 4.20.23 [SATISFIED] RESPONSE: | | | ACKNOWLEDGED. | | | | | | 6. ZONING REVIEW 4.20.23 [PARTIALLY SATISFIED] SITE | | | VISIBILITY CAN BE ADJUSTED TO BE FROM THE PROPERTY LINE | | | INTERSECTION WITH THE DRIVEWAY. | | | SEE SEC. 94-305 FOR MORE INFORMATION OR REFER TO FIGURE | | | X-1. | | | RESPONSE: PLEASE REFER TO REVISED SHEET A3.00 FOR | | | UPDATED SITE VISIBILITY. | | | | | | [ZONING REVIEW 5.23.23] NOT SATISFIED ??? SHOULD BE TWO | | | SEPARATE SITE VISIBILITY TRIANGLES. THE TIP OF TRIANGLE | | | SHOULD BEGIN AT THE BACK OF CURB. TRIANGLE THEN EXTENDS | | | 20 FEET SOUTHWARD (FOLLOWING THE DRIVEWAY) AND 20 FEET | | | EAST OR WEST ENCOMPASSING THE LANDSCAPE ADJACENT TO THE | | | DRIVEWAY APRON AND ROW . STAFF CAN PROVIDE DIAGRAM FOR | | | REFERENCE. | | | | | | | | | RESPONSE: SITE VISIBILITY TRIANGLES HAS BEEN APPLIED TO | | | PLAN | | | PLEASE REFER TO REVISED SHEET A3.01 | | | [ZONING REVIEW 6.13.23] SATISFIED | | | | | | 7. ZONING REVIEW 4.24.23 [NOT SATISFIED] | | | | | | [REPEAT COMMENT]: PLEASE NOTE FAR CALCULATIONS ARE THE | | | SAME AS GBA. PER SECTION 94-109. GROSS BUILDING AREA | | | MEANS THE TOTAL FLOOR AREA OF A BUILDING, INCLUDING | | | AIR- CONDITIONED OR FULLY ENCLOSED STORAGE SPACES, | | | ENCLOSED AREAS ON THE ROOFTOP, SUCH AS BATHROOMS AND | | | LOBBIES, STAIRS AND ELEVATOR AREAS, AND EXTERNAL | | | UNENCLOSED CIRCULATION AREAS. THE GROSS BUILDING AREA | | | DOES NOT INCLUDE PARKING | | | AREAS; UNENCLOSED COLONNADES, PORCHES AND BALCONIES; | | | MECHANICAL AND ELECTRICAL SPACES; AND TRASH ROOMS. | | | STORAGE SPACES WITHOUT WINDOWS AND ENCLOSED BY SURFACES | | | THAT ALLOW FOR NATURAL VENTILATION OR OUTSIDE AIR | | | CIRCULATION SHALL NOT BE INCLUDED. GROSS BUILDING AREA | | | REQUIREMENTS: | | | RESPONSE: PLEASE REFER TO SHEET A0.04 FOR REVISED FAR | | | CALCULATIONS. | | | [ZONING REVIEW 5.23.23] NOT SATISFIED. | | | | | | ON SHEET A0.04 ??? DIAGRAM 1 BASEMENT: ALL ELEVATORS | | | AND STAIRWELLS SHOULD BE INCLUDED WITHIN FAR CALC. | | | PLEASE CLARIFY ARE THE BIKE STORAGE SPACES ENCLOSED | | | WITHIN FENCING OR SOLID WALLS/ROOMS? IF ENCLOSED WITH | | | WALLS, NEEDS TO COUNT TOWARD FAR. | | | | | | ON SHEET A0.04 ??? DIAGRAM 2 GROUND LEVEL: BOH ROOM | | | ADJACENT TO OR LEFT OF THE MAILROOM CAN BE EXCLUDED | | | FROM FAR CALC. THE BIKE STORAGE ROOM SHOULD BE INCLUDED | | | WITHIN FAR CALC. STAIRWELL AT THE NORTHEASTERN CORNER | | | OF PROPERTY SHOULD BE INCLUDED WITHIN FAR CALC. | | | | | | ON SHEET A0.04 ??? DIAGRAM 4 2ND RESIDENTIAL LEVEL: | | | STAIRWELL AT THE NORTHEASTERN CORNER OF PROPERTY SHOULD | | | BE INCLUDED WITHIN FAR CALC. | | | | | | ON SHEET A0.04 ??? DIAGRAM 5 3RD ??? 12TH RESIDENTIAL | | | LEVEL: FAR CROSSHATCH LAYER APPEARS TO BE MISSING OR | | | UNDER THE OTHERS, ONLY SHOWN ON CORRIDORS AND | | | ELEVATORS, PLEASE REVISE. ALSO NOTE TO INCLUDE | | | STAIRWELL AT THE NORTHEASTERN CORNER OF PROPERTY WITHIN | | | FAR CALC. | | | | | | ON SHEET A0.04 ??? DIAGRAM 6 ROOF LEVEL: ALL ELEVATORS | | | AND STAIRWELLS SHOULD BE INCLUDED WITHIN FAR CALC. | | | | | | RESPONSE: DIAGRAMS HAVE BEEN REVISED ACCORDING TO | | | COMMENTS PLEASE REFER TO REVISED A0.04 | | | [ZONING REVIEW 6.13.23] PARTIALLY SATISFIED | | | | | | ON SHEET A0.04 ??? DIAGRAM 4 2ND RESIDENTIAL LEVEL ??? | | | THE BATHROOM ON THE OUTDOOR TERRACE SHALL BE INCLUDED | | | WITHIN THE FAR CALCULATIONS. | | | | | | 1. ANY PORTION OF THE PARKING AREA WHICH EXCEEDS THE | | | MAXIMUM PARKING RATIO SHALL BE INCLUDED IN THE | | | CALCULATIONS OF GROSS BUILDING AREA. THIS SHALL INCLUDE | | | STALLS AND ALL ASSOCIATED CIRCULATION AREAS. RESPONSE: | | | NOTED. PLEASE REVIEW GROSS BUIDING AREA CALCULATION. | | | PLEASE REFER TO REVISED SHEET A.0.04. | | | | | | 2. PARKING LOCATED BELOW GRADE SHALL NOT BE COUNTED AS | | | PART OF THE GROSS BUILDING AREA. | | | RESPONSE: PLEASE REVIEW GROSS BUIDLING AREA | | | CALCULATION, PARKING LOCATED BELOW GRADE IS NOT BEIGN | | | INCLUDE PLEASE REFER TO REVISED SHEET A.0.04. | | | | | | 3. THE GROSS BUILDING AREA SHALL BE MEASURED FROM THE | | | OUTSIDE FACE OF EXTERIOR WALLS. | | | RESPONSE: PLEASE REVIEW GROSS BUILDING AREA | | | CALCULATION, AREA IS | | | MEASURED FROM OUTSIDE FACE OF EXTERIOR WALLS | | | PLEASE REFER TO REVISED SHEET A.0.04. | | | | | | YOUR FAR CALCULATION NEEDS TO INCLUDE BOTH ELEVATORS | | | AND STAIRWELLS. DATA TABLE AND FIGURES ON A0.04 APPEAR | | | TO HAVE DISCREPANCIES IN CALCULATIONS. IT IS STILL | | | UNCLEAR TO STAFF WHAT SPACES ARE COUNTING TOWARD TOTAL | | | FAR AND WHAT IS BEING OMITTED; DUE TO BEING A | | | MECHANICAL/ELECTRIC ROOM, OR PARKING. STAFF | | | RECOMMENDATION IS TO SIMPLIFY THE CALCULATIONS TABLE | | | INTO A SINGLE ONE RATHER THAN SPLITTING INTO TWO | | | COMPONENTS. | | | STAFF ALSO RECOMMENDS A SIMPLE TWO-TONED GRAPHIC FOR | | | FAR ON SHEET | | | A0.04. BLANK OR WHITE SPACE = AREAS NOT COUNTED TOWARD | | | FAR TOTAL RED | | | OR SOME OTHER COLOR = SPACE THAT IS COUNTED TOWARD FAR | | | TOTAL | | | RESPONSE: ELEVATORS AND STAIRWELLS ARE INCLUDED; CHART | | | HAS BEEN UPDATED AND FAR IS SHOWING JUST ONE COLOR | | | HATCH AS REQUESTED. PLEASE REFER TO REVISED SHEET A.004 | | | FOR REVISED CALCULATIONS. | | | | | | [ZONING REVIEW 5.23.23] NOT SATISFIED, SEE COMMENTS | | | UNDER #7. | | | | | | RESPONSE: DIAGRAMS HAVE BEEN REVISED ACCORDING TO | | | COMMENTS PLEASE REFER TO REVISED A0.04 | | | [ZONING REVIEW 6.13.23] PARTIALLY SATISFIED | | | | | | ON SHEET A0.04 ??? DIAGRAM 4 2ND RESIDENTIAL LEVEL ??? | | | THE BATHROOM ON THE OUTDOOR TERRACE SHALL BE INCLUDED | | | WITHIN THE FAR CALCULATIONS. | | | | | | | | | 8. ZONING REVIEW 4.20.23 [SATISFIED] RESPONSE: | | | ACKNOWLEDGED. | | | | | | 9. ZONING REVIEW 4.24.23 [PARTIALLY SATISFIED] | | | PREVIOUS 12.09.22 SUBMITTAL HAD SETBACKS ALONG DATURA | | | MEASURED FROM THE CENTER OF THE ON-STREET PARKING. | | | WITHIN THIS 3.24.23 SUBMITTAL THE SETBACK IS BEING | | | MEASURED FROM THE BACK OF CURB, HOWEVER, THE | | | PREDOMINANT BACK OF CURB LINE IS THE INTERIOR CURB LINE | | | OF THE ON- STREET PARKING. PLEASE ADJUST. SHEET A3.01 | | | IS SHOWING TWO DIFFERENT | | | SETBACKS ON THE DATURA FRONTAGE. SEE SEC. 94-109 | | | SETBACK DEFINITION FOR MORE INFORMATION. | | | RESPONSE: PLEASE REFER TO REVISED SHEET A2.00 AND A3.01 | | | FOR REVISED SETBACK DIMENSION. | | | | | | [ZONING REVIEW 5.23.23] NOT SATISFIED. SETBACKS ARE | | | SHOW FROM PROPERTY LINE, THIS IS INCORRECT. SETBACKS | | | ARE MEASURED IN DOWNTOWN FROM BACK OF CURB. PLEASE NOTE | | | THIS IS FROM YOUR PREDOMINANT BACK OF CURB LINE, IN | | | THIS INSTANCE THE CURB LINE FROM THE ON-STREET PARKING. | | | A 16FT. SETBACK WOULD INCLUDE, THE MINIMUM 4 FT. | | | LANDSCAPE BUFFER, MINIMUM 8FT. SIDEWALK AND THEN 4 FEET | | | OF EXTRA SPACE. | | | | | | RESPONSE: SETBACK HAS BEEN CHANGED AND MESUARED FROM | | | BACK OF CURB AS REQUESTED. | | | PLEASE REFER TO REVISED SHEET A3.01 | | | [ZONING REVIEW 6.13.23] PARTIALLY SATISFIED | | | | | | SETBACKS ARE NOW SHOWN FROM CORRECT BACK OF CURB | | | LOCATION. SETBACK SHOWN AT 20FT. | | | | | | THE MINIMUM REQUIRED SETBACK IS 16 FT.; PLEASE SHOW | | | THIS MINIMUM REQUIRED LINE ON SITE PLAN, GROUND FLOOR, | | | AND ELEVATIONS SHEETS. | | | | | | 10. ZONING REVIEW 4.24.23 [SATISFIED] HISTORIC BUILDING | | | LEGAL NONCONFORMING, DOES NOT NEED TO MEET TRANSPARENCY | | | REQUIREMENTS. RESPONSE: NOTED. PLEASE REFER TO REVISED | | | SHEET. | | | | | | 11. ZONING REVIEW 4.24.23 [SATISFIED] RESTRICTIVE | | | COVENANT AND RECORDED DOCUMENTATION WILL BE A CONDITION | | | OF APPROVAL | | | RESPONSE: ACKNOWLEDGED. PLEASE CONFIRM THE | | | APPLICABILITY OF THE RESTRICTIVE COVENANT, THE VALET | | | OPERATIONS HAVE BEEN REMOVED AND THE PROJECT IS NOW | | | 100% SELF-PARK. | | | | | | 12. ZONING REVIEW 4.24.23 [SATISFIED] RESPONSE: | | | ACKNOWLEDGED. | | | | | | 13. ZONING REVIEW 4.24.23 [SATISFIED] RESPONSE: | | | ACKNOWLEDGED. | | | | | | 14. ZONING REVIEW 4.24.23 [SATISFIED] RESPONSE: | | | ACKNOWLEDGED. | | | | | | 15. ZONING REVIEW 4.24.23 [SATISFIED] RESPONSE: | | | ACKNOWLEDGED. | | | | | | FROM 1.19.23 COMMENTS | | | 1. ZONING REVIEW 4.24.23 [SATISFIED] RESPONSE: | | | ACKNOWLEDGED. | | | | | | 2. ZONING REVIEW 4.24.23 [NOT SATISFIED] | | | ON SHEET A3.01 AND OTHERS THE BIKE RACKS ARE SHOWN | | | PARALLEL TO SIDEWALK, IS THE 8FT. CLEAR PATH MAINTAINED | | | WITH THE BIKES IN THIS POSITION? SHEET A0.6.2 SHOWS | | | UTILIZATION OF???INVERTED U??? RACKS, WITH THESE RACKS | | | THE BIKES ARE TYPICALLY PERPENDICULAR TO SIDEWALK AS IT | | | IS EASIER TO ACCESS FOR USERS. SPACES CAN BE PARALLEL | | | BUT RECOMMEND PLACING THEM ON A SEPARATE PAD WITHIN | | | LANDSCAPE BUFFER OR ANOTHER DEDICATED SPACE, AS THIS | | | MAINTAINS THE 8FT. CLEARANCE ON SIDEWALK. MICROMOBILITY | | | STATION AND STREETLIGHTS STILL APPEAR TO OVERLAP STREET | | | TREE LOCATIONS. | | | RESPONSE: 8FT CLEARANCE ON SIDEWALK IS MAINTAINED. | | | [ZONING REVIEW 5.23.23] NOT SATISFIED. L-100 PLANS SHOW | | | BIKE RACKS IN MIDDLE OF SIDEWALK. PLEASE ILLUSTRATE ALL | | | STREETLIGHTS, STREETSCAPE FURNISHINGS, BIKE RACKS, | | | TREES, ETC. WITHIN LANDSCAPE PLAN, AND SITE PLAN OR | | | GROUND FLOOR PLAN. | | | RESPONSE: PLEASE REFER TO REVISED SHEET A3.01 AND L-100 | | | SIDEWALK CLEARANCE IS MANTAINED. | | | | | | [ZONING REVIEW 6.13.23] NOT SATISFIED. | | | L-100 SIDEWALK STILL SHOW BIKE RACKS LOCATED WITHIN | | | MIDDLE OF SIDEWALK, PLEASE ADJUST. A BIKE SHARE STATION | | | IS ALSO SHOWN ADJACENT TO THE DRIVEWAY, THIS | | | REQUIREMENT WAS REMOVED. | | | | | | STREETSCAPE ELEMENTS NOT SHOWN ON SITE PLAN A2.00, | | | GROUND FLOOR PLAN A3.01, OR LANDSCAPE PLAN L-200. WHERE | | | ARE THE BIKE RACKS AND STREET LIGHTS ILLUSTRATED? | | | | | | 3. ZONING REVIEW 4.24.23 [NOT SATISFIED] | | | STREET TREE ON EITHER SIDE OF THE DRIVEWAY ALONG DATURA | | | STREET ARE NOT SPACED 30FT. APART. THERE IS THE WIDTH | | | OF THE DRIVEWAY AND THE MICROMOBILITY STATION | | | INTERRUPTING THE TREE CONTINUITY. PLEASE ??? | | | RECONFIGURE TREES ON EITHER SIDE OF THE DRIVEWAY OR A | | | VARIANCE MUST BE REQUESTED AS IT DOES NOT MEET CODE | | | PROVISION OF SEC. 94-113(D.)(2.) | | | RESPONSE: PLEASE REFER TO REVISED SHEET A3.01 AND | | | INFORMATION PROVIDED | | | BY LANDSCAPE ARCHITECT, STREET TREES CANNOT BE PLACED | | | WITHIN THE DRIVEWAY SIGTH DISTANCE TRIANGLES, THIS IS | | | WHY THE STREET TREES ARE NOT 30??? APART. | | | MICROMOBILITY STATION HAS BEEN RELOCATED. | | | [ZONING REVIEW 5.23.23] NOT SATISFIED. SITE VISIBILITY | | | TRIANGLES ARE DRAWN FROM THE PROPERTY LINE OUTWARD, SEE | | | COMMENT #6. PLEASE NOTE LANDSCAPING CAN BE WITHIN THE | | | SITE VISIBILITY TRIANGLE SO LONG AS AN AREA BETWEEN | | | 18IN. AND 8FT. IS KEPT CLEAR. PLEASE REFERENCE SECTION | | | 94-305(E.) | | | | | | RESPONSE: SITE VISIBILITY TRIANGLES HAS BEEN APPLIED TO | | | PLAN | | | PLEASE REFER TO REVISED SHEET A3.01 | | | | | | [ZONING REVIEW 6.13.23] SATISFIED | | | | | | | | | | | | 4. ZONING REVIEW 4.24.23 [NOT SATISFIED] | | | ON THE NORTH EASTERN CORNER OF PROJECT, THE STAIRWELL | | | ENCROACHES INTO THE SETBACK. PLEASE ADJUST TO BE | | | OUTSIDE OF REQUIRED 5FT. SETBACK. ALSO PLEASE REMOVE | | | PLANTERS WITHIN 5 FT. SETBACK, SHOULD BE HEDGES PLANTED | | | AT 2-3 FOOT INTERVALS AND SHADE TREES EVERY 30 FT. | | | RESPONSE: PLEASE REFER TO REVISED SHEET A3.01, STAIR | | | HAS BEEN MOVED TO COMPLY WITH SETBACK. | | | [ZONING REVIEW 5.23.23] SATISFIED. PLEASE NOTE A3.02 | | | STILL SHOWS GRAPHIC ERROR WITH STAIR IN SETBACK. | | | RESPONSE: GRAPHIC ERROR HAS BEEN CORRECTED. | | | PLEASE REFER TO REVISED SHEET A3.02 | | | [ZONING REVIEW 6.13.23] SATISFIED | | | | | | 5. ZONING REVIEW 4.24.23 [NOT SATISFIED] | | | PER SEC. 94-113(F.)(1.) A 5 FOOT LANDSCAPE BUFFER IS | | | NEEDED WITH SHRUBS PLANTED AT 2 OR 3 FT. INTERVALS AS | | | WELL AS SHADE TREES PLANTED AT 30 FT. INTERVALS. | | | SUBMITTED PLANS DO NOT SHOW SHADE TREES. PLEASE REMOVE | | | PLANTERS AND ENCROACHING STAIRWELL. | | | RESPONSE: PLANTER HAVE BEEN REMOVED, SHRUBS ADDED AND | | | STAIR HAVE BEEN MOVED. PLEASE REFER TO REVISED SHEET | | | A3.00 AND INFORMATION PROVIDED BY LANDSCAPE ARCHITECT. | | | [ZONING REVIEW 5.23.23] SATISFIED. SHEET A3.01. | | | | | | ZONING COMMENTS 4.24.23: | | | | | | 1. PLEASE PROVIDE SIDEWALK AND CLEARPATH WIDTH FOR BOTH | | | DATURA AND S. DIXIE FRONTAGES. 8FT. CLEAR PATH REQUIRED | | | ON DATURA STREET FRONTAGE, SOUTH DIXIE HWY FRONTAGE TO | | | MAINTAIN EXISTING SIDEWALK WIDTH OR INCREASE COMPLIANCE | | | WITH REQUIRED 8FT. ALSO PROVIDE WIDTH OF LANDSCAPE | | | STRIP ALONG DATURA AND S DIXIE FRONTAGE. MICRO-MOBILITY | | | STATION CANNOT BE LOCATED WITHIN REQUIRED LANDSCAPE | | | STRIP ALONG DATURA FRONTAGE. | | | RESPONSE: PLEASE REFER TO REVISED SHEET A2.00 AND A3.01 | | | SHOWING DIMENTIONS OF SIDEWALKS, LANDSCAPE STRIP OR | | | DATURA AND S. DIXIE FRONTAGES, MICROBOLITY STATION HAS | | | BEEN MOVED. | | | ZONING REVIEW 5.23.23] SATISFIED. | | | | | | 2. PLEASE PROVIDE WIDTH OF DRIVEWAY OR CURBCUT WHERE IT | | | INTERSECTS WITH THE PROPERTY LINE, DIMENSION CANNOT | | | EXCEED 25FT. | | | RESPONSE: PLEASE REFER TO SHEET A3.01 SHOWING DIMENTION | | | OF DRIVEWAY. | | | ZONING REVIEW 5.23.23] SATISFIED. | | | | | | 3. ON THE ELEVATION DRAWINGS, PLEASE PROVIDE HEIGHT OF | | | ROOFTOP ELEMENTS (TRELLIS, DECORATIVE ELEMENTS, ETC.), | | | EACH ELEMENT MUST MEET THE PROJECTION STANDARDS OF SEC. | | | 94-109 TABLE IV-5. | | | RESPONSE: PLEASE REFER TO REVISED SHEETS A4.00, A4.02, | | | A4.03, A4.04 SHOWING HEIGHTS OF ROOFTOP ELEMENTS. | | | [ZONING REVIEW 5.23.23] SATISFIED. | | | | | | 4. PER SEC. 94-112 ALLEYS AND PUBLIC RIGHTS OF WAY: | | | INSTALLATION OF PUBLIC UTILITIES. ALL PROPOSED | | | DEVELOPMENTS EQUAL TO OR GREATER THAN 50,000 | | | GROSS SQUARE FEET SHALL HAVE ALL PUBLIC UTILITIES | | | SERVICE CONNECTIONS, INCLUDING TELEPHONE, CABLE AND | | | ELECTRIC DISTRIBUTION SERVICE INSTALLED UNDERGROUND. | | | RESPONSE: NOTED. | | | [ZONING REVIEW 5.23.23] SATISFIED. | | | | | | 5. PLEASE WALLMOUNT FDC IF LOCATED ALONG DATURA | | | FRONTAGE, AND PROVIDE SOME LANDSCAPING OR SCREENING SO | | | LONG AS ACCESS IS NOT HINDERED. | | | RESPONSE: PLEASE REFER TO REVISED SHEET A3.01, SHOWING | | | FDC AND A PROTECTION LANDSCAPE SCREEN. | | | [ZONING REVIEW 5.23.23] SATISFIED. | | | | | | 6. ON THE NORTH EASTERN CORNER OF PROJECT, THE | | | STAIRWELL ENCROACHES INTO THE SETBACK. PLEASE ADJUST TO | | | BE OUTSIDE OF REQUIRED 5FT. SETBACK. RESPONSE: PLEASE | | | REFER TO REVISED SHEET A3.01, STAIR HAS BEEN MOVED TO | | | COMPLY WITH SETBACK. | | | [ZONING REVIEW 5.23.23] SATISFIED. PLEASE NOTE A3.02 | | | STILL SHOWS GRAPHIC ERROR WITH STAIR IN SETBACK. | | | RESPONSE: GRAPHIC ERROR HAS BEEN CORRECTED. | | | PLEASE REFER TO REVISED SHEET A3.02 | | | [ZONING REVIEW 6.13.23] SATISFIED | | | | | | 7. LANDSCAPE TERMINAL ISLANDS AND BUILDING BASE | | | PLANTING ON THE REAR SURFACE PARKING DOES NOT SEEM | | | VIABLE AS IT IS UNDER THE AMENITY DECK/ROOF, THESE | | | AREAS WILL NOT HAVE DIRECT SUNLIGHT OR OPEN-AIR ACCESS. | | | RESPONSE: PLEASE REFER TO REVISED SHEET A3.01 PLANTERS | | | HAVE BEEN REMOVED. | | | [ZONING REVIEW 5.23.23] SATISFIED. | | | | | | 8. ART IN PUBLIC PLACES CONTRIBUTION OR ART LOCATION ON | | | SITE MUST BE IDENTIFIED PRIOR TO TAKING THE SITE PLAN | | | TO DAC. | | | RESPONSE: CONTRIBUTION WILL BE DISCUSSED WITH | | | OWNERSHIP/LAND USE LAWYER. | | | [ZONING REVIEW 5.23.23] SATISFIED. DISCUSSION HAD WITH | | | SYBILLE AND APPLICANT, NEW LOCATION PROPOSED WHERE | | | MICROMOBILITY STATION IS SHOWN ON CURRENT PLAN SET. | | | RESPONSE: PLEASE REFERR TO SHEET A6.09 SHOWING THE | | | PROPOSED ART IN PUBLIC SPACE LOCATION. | | | [ZONING REVIEW 6.13.23] SATISFIED. | | | | | | 9. LANDSCAPE PLANS CONFLICT WITH ARCHITECTURAL PLANS, | | | TREE LOCATIONS APPEAR TO DIFFER OR INTERFERE WITH SITE | | | ELEMENTS. BE SURE TO SHOW ON BOTH THE LANDSCAPE AND | | | ARCHITECTURE PLANS THE LOCATION OF ANY STREETSCAPE | | | ELEMENT (BIKERACK, LIGHTS, STREET TREES, FURNITURE, | | | METERS/VAULTS, PLANTERS, ETC.) | | | RESPONSE: PLEASE REFER TO REVISED SHEET A3.01 LANDSCAPE | | | AND ARCHITECTURE PLANS ARE COORDINATED. | | | [ZONING REVIEW 5.23.23] NOT SATISFIED. DOES NOT APPEAR | | | TO BE ADDRESSED. LIGHT POLES OVERLAP STREET TREE | | | CANOPY. BIKE RACKS ONLY SHOWN ON L-100 AND APPEAR TO BE | | | IN MIDDLE OF SIDEWALK. SEE COMMENT #2 FROM 04.24.23. | | | RESPONSE: PLEASE REFER TO REVISED SHEET A3.01 LANDSCAPE | | | AND ARCHITECTURE PLANS ARE COORDINATED. | | | | | | [ZONING REVIEW 6.13.23] PARTIALLY SATISFIED | | | L-100 SIDEWALK STILL SHOW BIKE RACKS LOCATED WITHIN | | | MIDDLE OF SIDEWALK, PLEASE ADJUST. A BIKE SHARE STATION | | | IS ALSO SHOWN ADJACENT TO THE DRIVEWAY, THIS | | | REQUIREMENT WAS REMOVED. | | | | | | STREETSCAPE ELEMENTS NOT SHOWN ON SITE PLAN A2.00, | | | GROUND FLOOR PLAN A3.01, OR LANDSCAPE PLAN L-200. WHERE | | | ARE THE BIKE RACKS AND STREET LIGHTS ILLUSTRATED? | | | | | | | | | 10. PLEASE LIST AND IDENTIFY ANY ZONING VARIANCES THAT | | | ARE REQUESTED. | | | RESPONSE: THERE ARE NO VARIANCES BEING REQUESTED AS | | | PART OF THIS PROJECT. | | | [ZONING REVIEW 5.23.23] NOT SATISFIED. IT IS UNDERSTOOD | | | THAT THE APPLICANT IS LOOKING TO PROCEED WITHOUT ANY | | | VARIANCES, HOWEVER THERE ARE SIGNIFICANT REVISIONS | | | NECESSARY, AS SOME UNSATISFIED COMMENTS WOULD WARRANT A | | | VARIANCE. | | | RESPONSE: NOTED | | | [ZONING REVIEW 6.13.23] SATISFIED | | | | | | THERE ARE MANY OUTSTANDING ZONING COMMENTS POSSIBLY DUE | | | TO MISINTERPRETATION OR CONFUSION WITH CODE ELEMENTS | | | AND/OR SITE CHANGES FROM THE PREVIOUS SUBMITTAL HAS | | | OUTLINED OR CAUSED NEW COMMENTS. STAFF WOULD LIKE TO | | | SUGGEST AN IN-PERSON MEETING WITH THE APPLICANT/DESIGN | | | TEAM TO CLARIFY THE REMAINING ZONING COMMENTS SO THAT | | | THE NEXT SUBMITTAL MORE SUFFICIENTLY ADDRESSES COMMENTS | | | AND IS OKAYED FOR THE NEXT STEP IN THE DESIGN PROCESS | | | (DAC APPROVAL). | | | RESPONSE: NOTED. | | | | | | [ZONING REVIEW 5.23.23] REPEAT COMMENT. STAFF SUGGESTS | | | MEETING TO CLARIFY NEXT SUBMITTAL. | | | | | | RESPONSE: NOTED | | | [ZONING REVIEW 6.13.23] SATISFIED | | | | | | | | | | | | | | | NEW COMMENTS 5.23.23: | | | | | | 1. CLOUDED VERSION OF PLANS DOES NOT MATCH UNCLOUDED | | | VERSION, EXAMPLE BEING A3.00 BASEMENT PARKING, CLOUDED | | | VERSION SHOWS LIFTS WHEREAS UNCLOUDED SHOWS CARSHARE. | | | BE SURE THAT ALL PLANS ARCHITECTURE, LANDSCAPE, AND | | | CIVIL ARE CONSISTENT. | | | RESPONSE: NOTED | | | [ZONING REVIEW 6.13.23] SATISFIED. ONLY CLOUDED SET | | | RESUBMITTED. | | | | | | | | | | | | 2. SETBACKS MEASURED FROM BACK OF CURB, NOT PROPERTY | | | LINE, PLEASE SEE COMMENT #9 FROM 4.24.23. | | | RESPONSE: SETBACK HAS BEEN CHANGED AND MESUARED FROM | | | BACK OF CURB AS REQUESTED. | | | PLEASE REFER TO REVISED SHEET A3.01 | | | [ZONING REVIEW 6.13.23] PARTIALLY SATISFIED | | | | | | SETBACKS ARE NOW SHOWN FROM CORRECT BACK OF CURB | | | LOCATION. SETBACK SHOWN AT 20FT. | | | | | | THE MINIMUM REQUIRED SETBACK IS 16 FT.; PLEASE SHOW | | | THIS MINIMUM REQUIRED LINE ON SITE PLAN, GROUND FLOOR, | | | AND ELEVATIONS SHEETS. | | | | | | | | | | | | 3. PLEASE PROVIDE PHOTOMETRIC PLAN FOR SITE. PLEASE | | | REFERENCE SEC. 94-113(B.) | | | EXTERIOR LIGHTING. ALL BUILDINGS SHALL PROVIDE EXTERIOR | | | LIGHTING EVERY NIGHT FROM DUSK TO DAWN TO ILLUMINATE | | | BUILDING ENTRANCES, ADJACENT SIDEWALKS, AND PATHS, AT A | | | MINIMUM OF 0.6 FOOTCANDLES AS MEASURED AT THE BACK EDGE | | | OF THE CURB AND ONE FOOT ABOVE THE SIDEWALK. THIS | | | MEASUREMENT SHALL INCLUDE LIGHT EMANATING FROM PUBLIC | | | AND PRIVATE SOURCES. UNSHIELDED LIGHT FIXTURES SHALL BE | | | PROHIBITED. | | | | | | RESPONSE: WILL BE PROVIDED | | | [ZONING REVIEW 6.13.23] NOT SATISFIED. | | | | | | WILL BE REQUIRED PRIOR TO ISSUANCE OF SITE PLAN | | | APPROVAL LETTER. | | | | | | | | | *** [6.16.23] STAFF TO FOLLOW UP WITH APPLICANT - MAY | | | CONDITION SEVERAL ITEMS FOR DAC *** |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
4 |
Status |
F |
Date |
05-31-2023 |
|
|
Cont ID |
|
| Sent By |
ckimmerl |
Date |
05-31-2023 |
Time |
17:04 |
Rev Time |
0.00 |
| Received By |
ckimmerl |
Date |
05-31-2023 |
Time |
17:03 |
Sent To |
|
|
| Notes |
| 2023-05-31 17:04:08 | 04/24/2023 | | | | | | 1. ZONING REVIEW 4.20.23 [NOT SATISFIED] | | | | | | TABLE ON SHEET A1.00 STILL APPEARS TO HAVE | | | DISCREPANCIES: | | | RESIDENTIAL PARKING MIN: 1SPACE/UNIT & 1SPACE/20UNIT | | | FOR GUEST 87 REGULAR UNITS = 87 SPACES + 5 SPACES FOR | | | GUEST = 92 REQUIRED SPACES RESPONSE: REGULAR UNITS = 65 | | | SPACES + 4 GUEST = 69 REQUIRED SPACES | | | PLEASE REFER TO SHEET A.100 FOR REVISED PARKING DATA | | | AND UNIT COUNT DATA. | | | | | | [ZONING REVIEW 5.23.23] SATISFIED ??? 69 SPACES; FOR 65 | | | UNITS AND 4 GUESTS | | | | | | 72 MICRO UNITS PROPOSED | | | DOES NOT REQUIRE PARKING MAX. PERMITTED: 0.5 | | | SPACES/UNIT + 1SPACE/20UNIT FOR GUEST | | | RESPONSE: 94 MICROUNITS DOES NOT REQUIRE PARKING. | | | PLEASE REFER TO SHEET A.100 FOR REVISED PARKING DATA | | | AND UNIT COUNT DATA. | | | | | | [ZONING REVIEW 5.23.23] SATISFIED ??? NO SPACES | | | PROVIDED FOR MICROUNITS | | | | | | LIVE/WORK PARKING MIN: 2 SPACES/1000SF | | | 4,464 SF OF LIVE/WORK ON GROUND FLOOR (6 UNITS AT 744 | | | EACH PER SHEET A3.01) | | | = 10 SPACES | | | 92 RES/GUEST + 10 LIVE/WORK = 102 REQUIRED PARKING | | | SPOTS NOT 130 | | | | | | RESPONSE: 69 RES/GUEST +10 LIVE/WORK = 79 REQUIRED | | | PARKING SPOTS PLEASE REFER TO REVISED SHEET A.100 FOR | | | REVISED PARKING DATA. | | | | | | [ZONING REVIEW 5.23.23] NOT SATISFIED ??? 6,678 SF OF | | | LIVEWORK ACCORDING TO A1.00 AND A0.04, REQUIRES A | | | MINIMUM OF 13 SPACES; ONLY PROVIDING 10. PLEASE PROVIDE | | | THE ADDITIONAL 3 SPACES. | | | | | | | | | HOWEVER, NOW THAT THE HISTORIC BUILDING AND ITS USES | | | ARE INCORPORATED INTO THE PROJECT SITE, PLEASE PROVIDE | | | USE/SQUAREFOOTAGE BREAKDOWN OF INTERIOR TENANTS, SO | | | THAT THESE USES CAN BE APPROPRIATELY PARKED. | | | | | | 5,750+5,778 SF = 11,528 SF OF POTENTIAL RETAIL OR | | | OFFICE USES THAT NEED PARKING. | | | RESPONSE: RETAIL / OFFICES PARKING = 23 P.S FOR A TOTAL | | | OF 102 P.S IN THE BUILDING. | | | PLEASE REFER TO SHEET A.100 FOR REVISED PARKING | | | [ZONING REVIEW 5.23.23] PARTIALLY SATISFIED ??? CLARIFY | | | THE USE WITHIN THE HISTORIC BUILDING. | | | IF SF IS ALL RETAIL/COMMERCIAL USE IT CAN BE PARKED AT | | | A MINIMUM OF 2 SPACES/1000SF. THEN THE PROPOSED 23 | | | SPACES IS SUFFICIENT. | | | IF SF IS ALL OFFICE USES IT CAN BE PARKED AT A MINIMUM | | | OF 2.5 SPACES/1000SF. WOULD REQUIRE 29 SPACES. | | | | | | PLEASE CLARIFY THE 8 GUEST SPACES, 12 LIVE/WORK SPACES, | | | AND 23 COMMERCIAL SPACES CALCULATIONS AS SHOWN IN | | | TABLE. | | | RESPONSE: PARKING HAVE BEEN REVISED PLEASE REFER TO | | | SHEET A.100 | | | THE BUILDING HAS 4 GUEST SPACES, 10 LIVE/WORKSPACES, 23 | | | COMMERCIAL/OFFICES SPACES AND 65 RESIDENTIAL SPACES FOR | | | A TOTAL OF 102 P.S. | | | [ZONING REVIEW 5.23.23] NOT SATISFIED ??? MINIMUM | | | REQUIRED PARKING IS 105 SPACES IF HISTORIC BUILDING IS | | | ALL RETAIL/COMMERCIAL. | | | | | | MINIMUM REQUIRED PARKING IS 111 SPACES IF HISTORIC | | | BUILDING IS ALL OFFICE. | | | | | | PLEASE CLARIFY IF YOU ARE PROVIDING PARKING FOR ANY OF | | | THE MICRO-UNITS. BICYCLE PARKING IS REQUIRED. | | | - 1 BICYCLE SPACE PER EVERY 15 PARKING SPACES (SHALL BE | | | WITHIN SECURED/COVERED ROOM). | | | RESPONSE: MICRO-UNITS DOES NOT REQUIRED PARKING 7 BIKE | | | SPACES REQUIRED PROVIDED ON BASEMENT. | | | PLEASE REFER TO REVISED SHEET A1.00 SHOWING REQUIRED | | | BIKE SPACES. | | | [ZONING REVIEW 5.23.23] SATISFIED ??? 57 BIKE SPACES; 7 | | | BIKE SPACES FOR REQ. PARKING, 3 SPACES FOR FRONTAGE, 47 | | | SPACES FOR 94 MICRO UNITS. | | | | | | - 1 BIKE SPACE PER 100 LINEAR FEET OF FRONTAGE. | | | RESPONSE: PLEASE REFER TO REVISED SHEET A1.00 SHOWING | | | REQUIRED BIKE SPACES CALCULATION. | | | [ZONING REVIEW 5.23.23] SATISFIED | | | | | | - WITH INCLUSION OF MICRO-UNITS ALSO NEED 0.5 BIKE | | | SPACES PER MICRO-UNIT. RESPONSE: PLEASE REFER TO | | | REVISED SHEET A.100 SHOWING BIKE SPACES CALCULATION. 47 | | | BIKE SPACES NEEDED FOR MICRONUNITS. | | | [ZONING REVIEW 5.23.23] SATISFIED | | | | | | - A BIKESHARING STATION IS ALSO REQUIRED ONSITE, PLEASE | | | CONTACT COLBY REESE 305-733-9650 [email protected] FOR | | | DIMENSIONS OF THE CITY???S BRIGHTBIKE STATIONS. | | | MICRO-MOBILITY STATION CANNOT BE LOCATED WITHIN | | | REQUIRED LANDSCAPE STRIP ALONG DATURA FRONTAGE. | | | RESPONSE: PLEASE REFER TO SHEET A3.00 BIKE RACK HAS | | | BEEN LOCATED. | | | [ZONING REVIEW 5.23.23] NOT SATISFIED ??? PLEASE | | | PROVIDE CORRESPONDENCE WITH CITY BIKESHARE OPERATOR OR | | | BRIGHTBIKE REP. COLBY REESE 305-733-9650 | | | [email protected]. | | | A STATION MAY BE REQUIRED ALONG PROJECT FRONTAGE OR | | | ALONG ROW. PROPOSED LOCATION ON A3.00 IS WITHIN | | | BASEMENT. PROJECT IS LOCATED WITHIN 500 FT. OF TWO | | | SEPARATE STATIONS WITHIN THE CITY, REQUIREMENT MAY BE | | | WAIVED. | | | | | | UPDATE: 5.31.23 PER DISCUSSION BETWEEN APPLICANT AND | | | COLBY, STATION IS NOT REQUIRED. [PARTIALLY SATISFIED] | | | PLEASE REMOVE MICRO-MOBILITY STATION FROM PLANS. | | | | | | | | | - A PROJECT WITH RESIDENTIAL MICRO-UNITS SHALL PROVIDE | | | ON-SITE CAR- SHARE STATIONS ON A RATIO OF ONE PER EVERY | | | 13 UNITS. THE TOTAL AMOUNT OF CAR-SHARE STATIONS MAY BE | | | REDUCED BY ONE CAR-SHARE STATION PER EVERY 13 ON-SITE | | | PARKING SPACES PROVIDED. THE TOTAL NUMBER OF CAR- SHARE | | | STATIONS MAY BE ADJUSTED BASED ON CURRENT SYSTEM | | | DEMANDS, BUT A MINIMUM OF ONE CAR-SHARE STATION SHALL | | | BE PROVIDED. THE REMAINDER OF THE SPACES SHALL BE | | | RESERVED FOR FUTURE SERVICE EXPANSION. | | | | | | RESPONSE: 8 CAR STATION PROVIDED.PLEASE REFER TO | | | REVISED SHEET A3.00 FOR CAR-SHARE STATION LOCATION. | | | [ZONING REVIEW 5.23.23] NOT SATISFIED ??? PLEASE LABEL | | | OR INDICATE WHICH SPACES ARE FOR CAR-SHARE, A3.00 DOES | | | NOT APPEAR TO HIGHLIGHT THESE SPACES. | | | | | | - A PROJECT WITH RESIDENTIAL MICRO-UNITS SHALL | | | CONTRIBUTE A TROLLEY FEE PER UNIT PER MONTH TO SUPPORT | | | THE OPERATION OF THE CITY'S TROLLEY SYSTEM, AS | | | ESTABLISHED BY RESOLUTION OF THE CITY COMMISSION FROM | | | TIME TO TIME. | | | RESPONSE: ACKNOWLEDGED. PLEASE ADVISE TO THE AMOUNTS, | | | PROCESS AND TIMING AS REQUIRED PER THE CITY | | | REGULATIONS. | | | [ZONING REVIEW 5.23.23] SATISFIED ??? PER RESOLUTION | | | NO. 211-17 ??????A TROLLEY FEE OF $10.00 PER UNIT PER | | | MONTH, FOR THE LIFE OF THE PROJECT, AT THE RATE | | | ESTABLISHED BY RESOLUTION 211-17 OR AS AMENDED BY THE | | | CITY COMMISSION. THE FIRST PAYMENT SHALL BE COMPLETED | | | AT THE TIME OF PROJECT CO.??? | | | | | | | | | 2. ZONING REVIEW 4.20.23 [NOT SATISFIED] | | | | | | WITHIN CWD 10-12 DISTRICT, THE PODIUM GOES UP TO LEVEL | | | 5. SUBMITTED PLANS ARE ONLY SHOWING PLANAR BREAKS FOR | | | GROUND FLOOR. SIMILAR TO SHEET A0.5.5 PLEASE SHOW | | | PLANER BREAKS FOR FLOORS 2-5 ALONG THE DATURA FRONTAGE. | | | PLEASE ADJUST THE CALCULATIONS AND AREA SHADED TO COUNT | | | ONLY THE PORTIONS WHERE THE PRIMARY FACE OR PLANE OF | | | THE BUILDING IS INTERRUPTED BY A 3 FT. + PROJECTION OR | | | RECESSED AREA. PLEASE PROVIDE THE DIMENSION OF THE | | | DEPTH OF THE RECESS OR PROJECTION AS WELL. SHEET A0.5.6 | | | AND A0.5.7 IS NOT NEEDED OR CALCULATIONS DO NOT NEED TO | | | BE PROVIDED; AS PLANAR BREAKS ARE ONLY FOR BUILDING | | | FRONTAGES LONGER THAN 150 FT. AND ON STREETS; IN THIS | | | CASE ONLY THE DATURA FRONTAGE. BECAUSE THE HISTORIC | | | BUILDING ALONG DIXIE ALREADY PROVIDES A BREAK IN THE | | | MASS AND IS ONLY 141-3 IN WIDTH. | | | RESPONSE: PLEASE REFER TO SHEET A0.5.6 SHOWING PLANAR | | | BREAKS FOR FLOORS 2-5 ALONG THE DATURA FRONTAGE. | | | | | | [ZONING REVIEW 5.23.23] PARTIALLY SATISFIED. TYPICALLY | | | ENTRYWAYS AND BALCONY PROJECTIONS OR RECESSED AREAS | | | WOULD NOT COUNT TOWARD PLANAR BREAK REQUIREMENTS. STAFF | | | ENCOURAGES ALTERNATIVE PLANAR BREAK PROPOSAL FOR FLOORS | | | 1-5 (PODIUM), PERHAPS WITHIN THE VERTICAL ELEMENTS | | | BETWEEN BALCONIES. HOWEVER, STAFF IS AMENABLE TO | | | INTERPRETING BALCONY AS PLANAR BREAK UNDER THE | | | CONDITION THAT GLASS OR TRANSPARENT RAILING MATERIALS | | | ARE UTILIZED, AS IS SHOWN IN THE RENDERS. CONDITION OF | | | DAC OR SITE PLAN APPROVAL. | | | | | | 3. ZONING REVIEW 4.20.23 [NOT SATISFIED] | | | PLEASE REVISE SHEET A0.03 AND L-203 MINOR TEXT | | | CORRECTION, OVERHEAD COVER IS NOT REQUIRED, IT IS JUST | | | PERMITTED UP TO A MAXIMUM PERCENTAGE OF THE SPACE. | | | WITHIN THE ROOFTOP GARDEN CALCULATIONS IT???S NOTED | | | ???REQUIRED 30%???. PRIVATE OPEN SPACE ON GROUND FLOOR | | | (GARDEN) IS NOT NEEDED AS THE REQUIREMENT IS MET WITH | | | ROOFTOP GARDEN. ALSO IF PRIVATE OPEN SPACE IS LOCATED | | | ON GROUND FLOOR, IT MUST BE DESIGNED TO MEET PUBLIC | | | OPEN SPACE REQUIREMENTS AND BE ACCESSIBLE TO THE | | | PUBLIC. RECOMMEND REMOVING REFERENCE TO GROUND FLOOR | | | PRIVATE SPACE. SATISFIED REQUIREMENT WITH ROOFTOP | | | SPACE. | | | RESPONSE: PLEASE REFER TO SHEET A0.03 FOR REVISED NOTE | | | AND GROUND FLOOR REFERENCE HAS BEEN REMOVED. | | | [ZONING REVIEW 5.23.23] SATISFIED | | | | | | 4. ZONING REVIEW 4.20.23 [SATISFIED] | | | RESPONSE: ACKNOWLEDGED. | | | | | | 5. ZONING REVIEW 4.20.23 [SATISFIED] | | | RESPONSE: ACKNOWLEDGED. | | | | | | 6. ZONING REVIEW 4.20.23 [PARTIALLY SATISFIED] SITE | | | VISIBILITY CAN BE ADJUSTED TO BE FROM THE PROPERTY LINE | | | INTERSECTION WITH THE DRIVEWAY. SEE SEC. 94-305 FOR | | | MORE INFORMATION OR REFER TO FIGURE X-1. | | | RESPONSE: PLEASE REFER TO REVISED SHEET A3.00 FOR | | | UPDATED SITE VISIBILITY. | | | | | | [ZONING REVIEW 5.23.23] NOT SATISFIED ??? SHOULD BE TWO | | | SEPARATE SITE VISIBILITY TRIANGLES. THE TIP OF TRIANGLE | | | SHOULD BEGIN AT THE BACK OF CURB. TRIANGLE THEN EXTENDS | | | 20 FEET SOUTHWARD (FOLLOWING THE DRIVEWAY) AND 20 FEET | | | EAST OR WEST ENCOMPASSING THE LANDSCAPE ADJACENT TO THE | | | DRIVEWAY APRON AND ROW . STAFF CAN PROVIDE DIAGRAM FOR | | | REFERENCE. | | | 7. ZONING REVIEW 4.24.23 [NOT SATISFIED] | | | | | | [REPEAT COMMENT]: PLEASE NOTE FAR CALCULATIONS ARE THE | | | SAME AS GBA. PER SECTION 94-109. GROSS BUILDING AREA | | | MEANS THE TOTAL FLOOR AREA OF A BUILDING, INCLUDING | | | AIR- CONDITIONED OR FULLY ENCLOSED STORAGE SPACES, | | | ENCLOSED AREAS ON THE ROOFTOP, SUCH AS BATHROOMS AND | | | LOBBIES, STAIRS AND ELEVATOR AREAS, AND EXTERNAL | | | UNENCLOSED CIRCULATION AREAS. THE GROSS BUILDING AREA | | | DOES NOT INCLUDE PARKING AREAS; UNENCLOSED COLONNADES, | | | PORCHES AND BALCONIES; MECHANICAL AND ELECTRICAL | | | SPACES; AND TRASH ROOMS. STORAGE SPACES WITHOUT WINDOWS | | | AND ENCLOSED BY SURFACES THAT ALLOW FOR NATURAL | | | VENTILATION OR OUTSIDE AIR CIRCULATION SHALL NOT BE | | | INCLUDED. GROSS BUILDING AREA REQUIREMENTS: | | | RESPONSE: PLEASE REFER TO SHEET A0.04 FOR REVISED FAR | | | CALCULATIONS. | | | [ZONING REVIEW 5.23.23] NOT SATISFIED. | | | | | | ON SHEET A0.04 ??? DIAGRAM 1 BASEMENT: ALL ELEVATORS | | | AND STAIRWELLS SHOULD BE INCLUDED WITHIN FAR CALC. | | | PLEASE CLARIFY ARE THE BIKE STORAGE SPACES ENCLOSED | | | WITHIN FENCING OR SOLID WALLS/ROOMS? IF ENCLOSED WITH | | | WALLS, NEEDS TO COUNT TOWARD FAR. | | | | | | ON SHEET A0.04 ??? DIAGRAM 2 GROUND LEVEL: BOH ROOM | | | ADJACENT TO OR LEFT OF THE MAILROOM CAN BE EXCLUDED | | | FROM FAR CALC. THE BIKE STORAGE ROOM SHOULD BE INCLUDED | | | WITHIN FAR CALC. STAIRWELL AT THE NORTHEASTERN CORNER | | | OF PROPERTY SHOULD BE INCLUDED WITHIN FAR CALC. | | | | | | ON SHEET A0.04 ??? DIAGRAM 4 2ND RESIDENTIAL LEVEL: | | | STAIRWELL AT THE NORTHEASTERN CORNER OF PROPERTY SHOULD | | | BE INCLUDED WITHIN FAR CALC. | | | | | | ON SHEET A0.04 ??? DIAGRAM 5 3RD ??? 12TH RESIDENTIAL | | | LEVEL: FAR CROSSHATCH LAYER APPEARS TO BE MISSING OR | | | UNDER THE OTHERS, ONLY SHOWN ON CORRIDORS AND | | | ELEVATORS, PLEASE REVISE. ALSO NOTE TO INCLUDE | | | STAIRWELL AT THE NORTHEASTERN CORNER OF PROPERTY WITHIN | | | FAR CALC. | | | | | | ON SHEET A0.04 ??? DIAGRAM 6 ROOF LEVEL: ALL ELEVATORS | | | AND STAIRWELLS SHOULD BE INCLUDED WITHIN FAR CALC. | | | | | | 1. ANY PORTION OF THE PARKING AREA WHICH EXCEEDS THE | | | MAXIMUM PARKING RATIO SHALL BE INCLUDED IN THE | | | CALCULATIONS OF GROSS BUILDING AREA. THIS SHALL INCLUDE | | | STALLS AND ALL ASSOCIATED CIRCULATION AREAS. RESPONSE: | | | NOTED. PLEASE REVIEW GROSS BUIDING AREA CALCULATION. | | | PLEASE REFER TO REVISED SHEET A.0.04. | | | | | | 2. PARKING LOCATED BELOW GRADE SHALL NOT BE COUNTED AS | | | PART OF THE GROSS BUILDING AREA. | | | RESPONSE: PLEASE REVIEW GROSS BUIDLING AREA | | | CALCULATION, PARKING LOCATED BELOW GRADE IS NOT BEIGN | | | INCLUDE | | | PLEASE REFER TO REVISED SHEET A.0.04. | | | | | | 3. THE GROSS BUILDING AREA SHALL BE MEASURED FROM THE | | | OUTSIDE FACE OF EXTERIOR WALLS. | | | RESPONSE: PLEASE REVIEW GROSS BUILDING AREA | | | CALCULATION, AREA IS MEASURED FROM OUTSIDE FACE OF | | | EXTERIOR WALLS | | | PLEASE REFER TO REVISED SHEET A.0.04. | | | | | | YOUR FAR CALCULATION NEEDS TO INCLUDE BOTH ELEVATORS | | | AND STAIRWELLS. DATA TABLE AND FIGURES ON A0.04 APPEAR | | | TO HAVE DISCREPANCIES IN CALCULATIONS. IT IS STILL | | | UNCLEAR TO STAFF WHAT SPACES ARE COUNTING TOWARD TOTAL | | | FAR AND WHAT IS BEING OMITTED; DUE TO BEING A | | | MECHANICAL/ELECTRIC ROOM, OR PARKING. STAFF | | | RECOMMENDATION IS TO SIMPLIFY THE CALCULATIONS TABLE | | | INTO A SINGLE ONE RATHER THAN SPLITTING INTO TWO | | | COMPONENTS. | | | STAFF ALSO RECOMMENDS A SIMPLE TWO-TONED GRAPHIC FOR | | | FAR ON SHEET A0.04. BLANK OR WHITE SPACE = AREAS NOT | | | COUNTED TOWARD FAR TOTAL RED OR SOME OTHER COLOR = | | | SPACE THAT IS COUNTED TOWARD FAR TOTAL | | | RESPONSE: ELEVATORS AND STAIRWELLS ARE INCLUDED; CHART | | | HAS BEEN UPDATED AND FAR IS SHOWING JUST ONE COLOR | | | HATCH AS REQUESTED. | | | PLEASE REFER TO REVISED SHEET A.004 FOR REVISED | | | CALCULATIONS. | | | | | | [ZONING REVIEW 5.23.23] NOT SATISFIED, SEE COMMENTS | | | UNDER #7. | | | | | | | | | 8. ZONING REVIEW 4.20.23 [SATISFIED] | | | RESPONSE: ACKNOWLEDGED. | | | | | | 9. ZONING REVIEW 4.24.23 [PARTIALLY SATISFIED] | | | | | | PREVIOUS 12.09.22 SUBMITTAL HAD SETBACKS ALONG DATURA | | | MEASURED FROM THE CENTER OF THE ON-STREET PARKING. | | | WITHIN THIS 3.24.23 SUBMITTAL THE SETBACK IS BEING | | | MEASURED FROM THE BACK OF CURB, HOWEVER, THE | | | PREDOMINANT BACK OF CURB LINE IS THE INTERIOR CURB LINE | | | OF THE ON- STREET PARKING. PLEASE ADJUST. SHEET A3.01 | | | IS SHOWING TWO DIFFERENT SETBACKS ON THE DATURA | | | FRONTAGE. SEE SEC. 94-109 SETBACK DEFINITION FOR MORE | | | INFORMATION. | | | RESPONSE: PLEASE REFER TO REVISED SHEET A2.00 AND A3.01 | | | FOR REVISED SETBACK DIMENSION. | | | | | | [ZONING REVIEW 5.23.23] NOT SATISFIED. SETBACKS ARE | | | SHOW FROM PROPERTY LINE, THIS IS INCORRECT. SETBACKS | | | ARE MEASURED IN DOWNTOWN FROM BACK OF CURB. PLEASE NOTE | | | THIS IS FROM YOUR PREDOMINANT BACK OF CURB LINE, IN | | | THIS INSTANCE THE CURB LINE FROM THE ON-STREET PARKING. | | | A 16FT. SETBACK WOULD INCLUDE, THE MINIMUM 4 FT. | | | LANDSCAPE BUFFER, MINIMUM 8FT. SIDEWALK AND THEN 4 FEET | | | OF EXTRA SPACE. | | | | | | 10. ZONING REVIEW 4.24.23 [SATISFIED] HISTORIC BUILDING | | | LEGAL NONCONFORMING, DOES NOT NEED TO MEET | | | TRANSPARENCY REQUIREMENTS. RESPONSE: NOTED. PLEASE | | | REFER TO REVISED SHEET. | | | | | | 11. ZONING REVIEW 4.24.23 [SATISFIED] RESTRICTIVE | | | COVENANT AND RECORDED DOCUMENTATION WILL BE A CONDITION | | | OF APPROVAL | | | RESPONSE: ACKNOWLEDGED. PLEASE CONFIRM THE | | | APPLICABILITY OF THE RESTRICTIVE COVENANT, THE VALET | | | OPERATIONS HAVE BEEN REMOVED AND THE PROJECT IS NOW | | | 100% SELF-PARK. | | | | | | 12. ZONING REVIEW 4.24.23 [SATISFIED] | | | RESPONSE: ACKNOWLEDGED. | | | | | | 13. ZONING REVIEW 4.24.23 [SATISFIED] | | | RESPONSE: ACKNOWLEDGED. | | | | | | 14. ZONING REVIEW 4.24.23 [SATISFIED] | | | RESPONSE: ACKNOWLEDGED. | | | | | | 15. ZONING REVIEW 4.24.23 [SATISFIED] | | | RESPONSE: ACKNOWLEDGED. | | | | | | FROM 1.19.23 COMMENTS | | | 1. ZONING REVIEW 4.24.23 [SATISFIED] | | | RESPONSE: ACKNOWLEDGED. | | | | | | 2. ZONING REVIEW 4.24.23 [NOT SATISFIED] | | | ON SHEET A3.01 AND OTHERS THE BIKE RACKS ARE SHOWN | | | PARALLEL TO SIDEWALK, IS THE 8FT. CLEAR PATH MAINTAINED | | | WITH THE BIKES IN THIS POSITION? SHEET A0.6.2 SHOWS | | | UTILIZATION OF???INVERTED U??? RACKS, WITH THESE RACKS | | | THE BIKES ARE TYPICALLY PERPENDICULAR TO SIDEWALK AS IT | | | IS EASIER TO ACCESS FOR USERS. SPACES CAN BE PARALLEL | | | BUT RECOMMEND PLACING THEM ON A SEPARATE PAD WITHIN | | | LANDSCAPE BUFFER OR ANOTHER DEDICATED SPACE, AS THIS | | | MAINTAINS THE 8FT. CLEARANCE ON SIDEWALK. MICROMOBILITY | | | STATION AND STREETLIGHTS STILL APPEAR TO OVERLAP STREET | | | TREE LOCATIONS. | | | RESPONSE: 8FT CLEARANCE ON SIDEWALK IS MAINTAINED. | | | [ZONING REVIEW 5.23.23] NOT SATISFIED. L-100 PLANS SHOW | | | BIKE RACKS IN MIDDLE OF SIDEWALK. PLEASE ILLUSTRATE ALL | | | STREETLIGHTS, STREETSCAPE FURNISHINGS, BIKE RACKS, | | | TREES, ETC. WITHIN LANDSCAPE PLAN, AND SITE PLAN OR | | | GROUND FLOOR PLAN. | | | | | | 3. ZONING REVIEW 4.24.23 [NOT SATISFIED] | | | STREET TREE ON EITHER SIDE OF THE DRIVEWAY ALONG DATURA | | | STREET ARE NOT SPACED 30FT. APART. THERE IS THE WIDTH | | | OF THE DRIVEWAY AND THE MICROMOBILITY STATION | | | INTERRUPTING THE TREE CONTINUITY. PLEASE | | | | | | RECONFIGURE TREES ON EITHER SIDE OF THE DRIVEWAY OR A | | | VARIANCE MUST BE REQUESTED AS IT DOES NOT MEET CODE | | | PROVISION OF SEC. 94-113(D.)(2.) RESPONSE: PLEASE REFER | | | TO REVISED SHEET A3.01 AND INFORMATION PROVIDED BY | | | LANDSCAPE ARCHITECT, STREET TREES CANNOT BE PLACED | | | WITHIN THE DRIVEWAY SIGTH DISTANCE TRIANGLES, THIS IS | | | WHY THE STREET TREES ARE NOT 30??? APART. | | | MICROMOBILITY STATION HAS BEEN RELOCATED. | | | [ZONING REVIEW 5.23.23] NOT SATISFIED. SITE VISIBILITY | | | TRIANGLES ARE DRAWN FROM THE PROPERTY LINE OUTWARD, SEE | | | COMMENT #6. PLEASE NOTE LANDSCAPING CAN BE WITHIN THE | | | SITE VISIBILITY TRIANGLE SO LONG AS AN AREA BETWEEN | | | 18IN. AND 8FT. IS KEPT CLEAR. PLEASE REFERENCE SECTION | | | 94-305(E.) | | | | | | | | | 4. ZONING REVIEW 4.24.23 [NOT SATISFIED] | | | ON THE NORTH EASTERN CORNER OF PROJECT, THE STAIRWELL | | | ENCROACHES INTO THE SETBACK. PLEASE ADJUST TO BE | | | OUTSIDE OF REQUIRED 5FT. SETBACK. ALSO PLEASE REMOVE | | | PLANTERS WITHIN 5 FT. SETBACK, SHOULD BE HEDGES PLANTED | | | AT 2-3 FOOT INTERVALS AND SHADE TREES EVERY 30 FT. | | | RESPONSE: PLEASE REFER TO REVISED SHEET A3.01, STAIR | | | HAS BEEN MOVED TO COMPLY WITH SETBACK. | | | [ZONING REVIEW 5.23.23] SATISFIED. PLEASE NOTE A3.02 | | | STILL SHOWS GRAPHIC ERROR WITH STAIR IN SETBACK. | | | | | | 5. ZONING REVIEW 4.24.23 [NOT SATISFIED] | | | PER SEC. 94-113(F.)(1.) A 5 FOOT LANDSCAPE BUFFER IS | | | NEEDED WITH SHRUBS PLANTED AT 2 OR 3 FT. INTERVALS AS | | | WELL AS SHADE TREES PLANTED AT 30 FT. INTERVALS. | | | SUBMITTED PLANS DO NOT SHOW SHADE TREES. PLEASE REMOVE | | | PLANTERS AND ENCROACHING STAIRWELL. | | | RESPONSE: PLANTER HAVE BEEN REMOVED, SHRUBS ADDED AND | | | STAIR HAVE BEEN MOVED. PLEASE REFER TO REVISED SHEET | | | A3.00 AND INFORMATION PROVIDED BY LANDSCAPE ARCHITECT. | | | [ZONING REVIEW 5.23.23] SATISFIED. SHEET A3.01. | | | | | | ZONING COMMENTS 4.24.23: | | | | | | 1. PLEASE PROVIDE SIDEWALK AND CLEARPATH WIDTH FOR BOTH | | | DATURA AND | | | S. DIXIE FRONTAGES. 8FT. CLEAR PATH REQUIRED ON DATURA | | | STREET FRONTAGE, SOUTH DIXIE HWY FRONTAGE TO MAINTAIN | | | EXISTING SIDEWALK WIDTH OR INCREASE COMPLIANCE WITH | | | REQUIRED 8FT. ALSO PROVIDE WIDTH OF LANDSCAPE STRIP | | | ALONG DATURA AND S DIXIE FRONTAGE. MICRO-MOBILITY | | | STATION CANNOT BE LOCATED WITHIN REQUIRED LANDSCAPE | | | STRIP ALONG DATURA FRONTAGE. | | | RESPONSE: PLEASE REFER TO REVISED SHEET A2.00 AND A3.01 | | | SHOWING DIMENTIONS OF SIDEWALKS, LANDSCAPE STRIP OR | | | DATURA AND S. DIXIE FRONTAGES, MICROBOLITY STATION HAS | | | BEEN MOVED. | | | ZONING REVIEW 5.23.23] SATISFIED. | | | | | | 2. PLEASE PROVIDE WIDTH OF DRIVEWAY OR CURBCUT WHERE IT | | | INTERSECTS WITH THE PROPERTY LINE, DIMENSION CANNOT | | | EXCEED 25FT. | | | RESPONSE: PLEASE REFER TO SHEET A3.01 SHOWING DIMENTION | | | OF DRIVEWAY. | | | ZONING REVIEW 5.23.23] SATISFIED. | | | | | | 3. ON THE ELEVATION DRAWINGS, PLEASE PROVIDE HEIGHT OF | | | ROOFTOP ELEMENTS (TRELLIS, DECORATIVE ELEMENTS, ETC.), | | | EACH ELEMENT MUST MEET THE PROJECTION STANDARDS OF SEC. | | | 94-109 TABLE IV-5. | | | RESPONSE: PLEASE REFER TO REVISED SHEETS A4.00, A4.02, | | | A4.03, A4.04 SHOWING HEIGHTS OF ROOFTOP ELEMENTS. | | | [ZONING REVIEW 5.23.23] SATISFIED. | | | | | | 4. PER SEC. 94-112 ALLEYS AND PUBLIC RIGHTS OF WAY: | | | INSTALLATION OF PUBLIC UTILITIES. ALL PROPOSED | | | DEVELOPMENTS EQUAL TO OR GREATER THAN 50,000 GROSS | | | SQUARE FEET SHALL HAVE ALL PUBLIC UTILITIES SERVICE | | | CONNECTIONS, | | | | | | INCLUDING TELEPHONE, CABLE AND ELECTRIC DISTRIBUTION | | | SERVICE INSTALLED UNDERGROUND. | | | RESPONSE: NOTED. | | | [ZONING REVIEW 5.23.23] SATISFIED. | | | | | | 5. PLEASE WALLMOUNT FDC IF LOCATED ALONG DATURA | | | FRONTAGE, AND PROVIDE SOME LANDSCAPING OR SCREENING SO | | | LONG AS ACCESS IS NOT HINDERED. | | | RESPONSE: PLEASE REFER TO REVISED SHEET A3.01, SHOWING | | | FDC AND A PROTECTION LANDSCAPE SCREEN. | | | [ZONING REVIEW 5.23.23] SATISFIED. | | | | | | 6. ON THE NORTH EASTERN CORNER OF PROJECT, THE | | | STAIRWELL ENCROACHES INTO THE SETBACK. PLEASE ADJUST TO | | | BE OUTSIDE OF REQUIRED 5FT. SETBACK. RESPONSE: PLEASE | | | REFER TO REVISED SHEET A3.01, STAIR HAS BEEN MOVED TO | | | COMPLY WITH SETBACK. | | | [ZONING REVIEW 5.23.23] SATISFIED. PLEASE NOTE A3.02 | | | STILL SHOWS GRAPHIC ERROR WITH STAIR IN SETBACK. | | | | | | 7. LANDSCAPE TERMINAL ISLANDS AND BUILDING BASE | | | PLANTING ON THE REAR SURFACE PARKING DOES NOT SEEM | | | VIABLE AS IT IS UNDER THE AMENITY DECK/ROOF, THESE | | | AREAS WILL NOT HAVE DIRECT SUNLIGHT OR OPEN-AIR ACCESS. | | | RESPONSE: PLEASE REFER TO REVISED SHEET A3.01 PLANTERS | | | HAVE BEEN REMOVED. | | | [ZONING REVIEW 5.23.23] SATISFIED. | | | | | | 8. ART IN PUBLIC PLACES CONTRIBUTION OR ART LOCATION ON | | | SITE MUST BE IDENTIFIED PRIOR TO TAKING THE SITE PLAN | | | TO DAC. | | | RESPONSE: CONTRIBUTION WILL BE DISCUSSED WITH | | | OWNERSHIP/LAND USE LAWYER. | | | [ZONING REVIEW 5.23.23] SATISFIED. DISCUSSION HAD WITH | | | SYBILLE AND APPLICANT, NEW LOCATION PROPOSED WHERE | | | MICROMOBILITY STATION IS SHOWN ON CURRENT PLAN SET. | | | | | | 9. LANDSCAPE PLANS CONFLICT WITH ARCHITECTURAL PLANS, | | | TREE LOCATIONS APPEAR TO DIFFER OR INTERFERE WITH SITE | | | ELEMENTS. BE SURE TO SHOW ON BOTH THE LANDSCAPE AND | | | ARCHITECTURE PLANS THE LOCATION OF ANY STREETSCAPE | | | ELEMENT (BIKERACK, LIGHTS, STREET TREES, FURNITURE, | | | METERS/VAULTS, PLANTERS, ETC.) | | | RESPONSE: PLEASE REFER TO REVISED SHEET A3.01 LANDSCAPE | | | AND ARCHITECTURE PLANS ARE COORDINATED. | | | [ZONING REVIEW 5.23.23] NOT SATISFIED. DOES NOT APPEAR | | | TO BE ADDRESSED. LIGHT POLES OVERLAP STREET TREE | | | CANOPY. BIKE RACKS ONLY SHOWN ON L-100 AND APPEAR TO BE | | | IN MIDDLE OF SIDEWALK. SEE COMMENT #2 FROM 04.24.23. | | | | | | 10. PLEASE LIST AND IDENTIFY ANY ZONING VARIANCES THAT | | | ARE REQUESTED. | | | RESPONSE: THERE ARE NO VARIANCES BEING REQUESTED AS | | | PART OF THIS PROJECT. | | | [ZONING REVIEW 5.23.23] NOT SATISFIED. IT IS UNDERSTOOD | | | THAT THE APPLICANT IS LOOKING TO PROCEED WITHOUT ANY | | | VARIANCES, HOWEVER THERE ARE SIGNIFICANT REVISIONS | | | NECESSARY, AS SOME UNSATISFIED COMMENTS WOULD WARRANT A | | | VARIANCE. | | | | | | THERE ARE MANY OUTSTANDING ZONING COMMENTS POSSIBLY DUE | | | TO MISINTERPRETATION OR CONFUSION WITH CODE ELEMENTS | | | AND/OR SITE CHANGES FROM THE PREVIOUS SUBMITTAL HAS | | | OUTLINED OR CAUSED NEW COMMENTS. STAFF WOULD LIKE TO | | | SUGGEST AN IN-PERSON MEETING WITH THE APPLICANT/DESIGN | | | TEAM TO CLARIFY THE REMAINING ZONING COMMENTS SO THAT | | | THE NEXT SUBMITTAL MORE SUFFICIENTLY ADDRESSES COMMENTS | | | AND IS OKAYED FOR THE NEXT STEP IN THE DESIGN PROCESS | | | (DAC APPROVAL). | | | RESPONSE: NOTED. | | | | | | [ZONING REVIEW 5.23.23] REPEAT COMMENT. STAFF SUGGESTS | | | MEETING TO CLARIFY NEXT SUBMITTAL. | | | | | | | | | | | | | | | | | | NEW COMMENTS 5.23.23: | | | | | | 1. CLOUDED VERSION OF PLANS DOES NOT MATCH UNCLOUDED | | | VERSION, EXAMPLE BEING A3.00 BASEMENT PARKING, CLOUDED | | | VERSION SHOWS LIFTS WHEREAS UNCLOUDED SHOWS CARSHARE. | | | BE SURE THAT ALL PLANS ARCHITECTURE, LANDSCAPE, AND | | | CIVIL ARE CONSISTENT. | | | | | | 2. SETBACKS MEASURED FROM BACK OF CURB, NOT PROPERTY | | | LINE, PLEASE SEE COMMENT #9 FROM 4.24.23. | | | | | | 3. PLEASE PROVIDE PHOTOMETRIC PLAN FOR SITE. PLEASE | | | REFERENCE SEC. 94-113(B.) | | | EXTERIOR LIGHTING. ALL BUILDINGS SHALL PROVIDE EXTERIOR | | | LIGHTING EVERY NIGHT FROM DUSK TO DAWN TO ILLUMINATE | | | BUILDING ENTRANCES, ADJACENT SIDEWALKS, AND PATHS, AT A | | | MINIMUM OF 0.6 FOOTCANDLES AS MEASURED AT THE BACK EDGE | | | OF THE CURB AND ONE FOOT ABOVE THE SIDEWALK. THIS | | | MEASUREMENT SHALL INCLUDE LIGHT EMANATING FROM PUBLIC | | | AND PRIVATE SOURCES. UNSHIELDED LIGHT FIXTURES SHALL BE | | | PROHIBITED. | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
F |
Date |
04-24-2023 |
|
|
Cont ID |
|
| Sent By |
ckimmerl |
Date |
04-24-2023 |
Time |
17:42 |
Rev Time |
0.00 |
| Received By |
ckimmerl |
Date |
04-24-2023 |
Time |
17:36 |
Sent To |
|
|
| Notes |
| 2023-04-24 17:42:16 | 1. ZONING REVIEW 4.20.23 [NOT SATISFIED] | | | | | | TABLE ON SHEET A1.00 STILL APPEARS TO HAVE | | | DISCREPANCIES: | | | RESIDENTIAL PARKING MIN: 1SPACE/UNIT & 1SPACE/20UNIT | | | FOR GUEST | | | 87 REGULAR UNITS = 87 SPACES + 5 SPACES FOR GUEST = 92 | | | REQUIRED SPACES | | | 72 MICRO UNITS PROPOSED ??? DOES NOT REQUIRE PARKING | | | MAX. PERMITTED: 0.5 SPACES/UNIT + 1SPACE/20UNIT FOR | | | GUEST | | | LIVE/WORK PARKING MIN: 2 SPACES/1000SF | | | 4,464 SF OF LIVE/WORK ON GROUND FLOOR (6 UNITS AT 744 | | | EACH PER SHEET A3.01) = 10 SPACES | | | 92 RES/GUEST + 10 LIVE/WORK = 102 REQUIRED PARKING | | | SPOTS NOT 130 | | | HOWEVER, NOW THAT THE HISTORIC BUILDING AND ITS USES | | | ARE INCORPORATED INTO THE PROJECT SITE, PLEASE PROVIDE | | | USE/SQUAREFOOTAGE BREAKDOWN OF INTERIOR TENANTS, SO | | | THAT THESE USES CAN BE APPROPRIATELY PARKED. | | | 5,750+5,778 SF = 11,528 SF OF POTENTIAL RETAIL OR | | | OFFICE USES THAT NEED PARKING. | | | PLEASE CLARIFY THE 8 GUEST SPACES, 12 LIVE/WORK SPACES, | | | AND 23 COMMERCIAL SPACES CALCULATIONS AS SHOWN IN | | | TABLE. | | | PLEASE CLARIFY IF YOU ARE PROVIDING PARKING FOR ANY OF | | | THE MICRO-UNITS. | | | BICYCLE PARKING IS REQUIRED. | | | - 1 BICYCLE SPACE PER EVERY 15 PARKING SPACES (SHALL BE | | | WITHIN SECURED/COVERED ROOM). | | | - 1 BIKE SPACE PER 100 LINEAR FEET OF FRONTAGE. | | | - WITH INCLUSION OF MICRO-UNITS ALSO NEED 0.5 BIKE | | | SPACES PER MICRO-UNIT. | | | | | | - A BIKESHARING STATION IS ALSO REQUIRED ONSITE, PLEASE | | | CONTACT COLBY REESE 305-733-9650 [email protected] FOR | | | DIMENSIONS OF THE CITY???S BRIGHTBIKE STATIONS. | | | MICRO-MOBILITY STATION CANNOT BE LOCATED WITHIN | | | REQUIRED LANDSCAPE STRIP ALONG DATURA FRONTAGE. | | | - A PROJECT WITH RESIDENTIAL MICRO-UNITS SHALL PROVIDE | | | ON-SITE CAR-SHARE STATIONS ON A RATIO OF ONE PER EVERY | | | 13 UNITS. THE TOTAL AMOUNT OF CAR-SHARE STATIONS MAY BE | | | REDUCED BY ONE CAR-SHARE STATION PER EVERY 13 ON-SITE | | | PARKING SPACES PROVIDED. THE TOTAL NUMBER OF CAR-SHARE | | | STATIONS MAY BE ADJUSTED BASED ON CURRENT SYSTEM | | | DEMANDS, BUT A MINIMUM OF ONE CAR-SHARE STATION SHALL | | | BE PROVIDED. THE REMAINDER OF THE SPACES SHALL BE | | | RESERVED FOR FUTURE SERVICE EXPANSION. | | | - A PROJECT WITH RESIDENTIAL MICRO-UNITS SHALL | | | CONTRIBUTE A TROLLEY FEE PER UNIT PER MONTH TO SUPPORT | | | THE OPERATION OF THE CITY'S TROLLEY SYSTEM, AS | | | ESTABLISHED BY RESOLUTION OF THE CITY COMMISSION FROM | | | TIME TO TIME. | | | | | | 2. ZONING REVIEW 4.20.23 [NOT SATISFIED] | | | | | | WITHIN CWD 10-12 DISTRICT, THE PODIUM GOES UP TO LEVEL | | | 5. SUBMITTED PLANS ARE ONLY SHOWING PLANAR BREAKS FOR | | | GROUND FLOOR. SIMILAR TO SHEET A0.5.5 PLEASE SHOW | | | PLANER BREAKS FOR FLOORS 2-5 ALONG THE DATURA FRONTAGE. | | | PLEASE ADJUST THE CALCULATIONS AND AREA SHADED TO COUNT | | | ONLY THE PORTIONS WHERE THE PRIMARY FACE OR PLANE OF | | | THE BUILDING IS INTERRUPTED BY A 3 FT. + PROJECTION OR | | | RECESSED AREA. PLEASE PROVIDE THE DIMENSION OF THE | | | DEPTH OF THE RECESS OR PROJECTION AS WELL. | | | SHEET A0.5.6 AND A0.5.7 IS NOT NEEDED OR CALCULATIONS | | | DO NOT NEED TO BE PROVIDED; AS PLANAR BREAKS ARE ONLY | | | FOR BUILDING FRONTAGES LONGER THAN 150 FT. AND ON | | | STREETS; IN THIS CASE ONLY THE DATURA FRONTAGE. BECAUSE | | | THE HISTORIC BUILDING ALONG DIXIE ALREADY PROVIDES A | | | BREAK IN THE MASS AND IS ONLY 141???-3??? IN WIDTH. | | | | | | 3. ZONING REVIEW 4.20.23 [NOT SATISFIED] | | | PLEASE REVISE SHEET A0.03 AND L-203 | | | MINOR TEXT CORRECTION, OVERHEAD COVER IS NOT REQUIRED, | | | IT IS JUST PERMITTED UP TO A MAXIMUM PERCENTAGE OF THE | | | SPACE. WITHIN THE ROOFTOP GARDEN CALCULATIONS IT???S | | | NOTED ???REQUIRED 30%???. | | | PRIVATE OPEN SPACE ON GROUND FLOOR (GARDEN) IS NOT | | | NEEDED AS THE REQUIREMENT IS MET WITH ROOFTOP GARDEN. | | | ALSO IF PRIVATE OPEN SPACE IS LOCATED ON GROUND FLOOR, | | | IT MUST BE DESIGNED TO MEET PUBLIC OPEN SPACE | | | REQUIREMENTS AND BE ACCESSIBLE TO THE PUBLIC. RECOMMEND | | | REMOVING REFERENCE TO GROUND FLOOR PRIVATE SPACE. | | | SATISFIED REQUIREMENT WITH ROOFTOP SPACE. | | | | | | 4. ZONING REVIEW 4.20.23 [SATISFIED] | | | | | | 5. ZONING REVIEW 4.20.23 [SATISFIED] | | | | | | 6. ZONING REVIEW 4.20.23 [PARTIALLY SATISFIED] SITE | | | VISIBILITY CAN BE ADJUSTED TO BE FROM THE PROPERTY LINE | | | INTERSECTION WITH THE DRIVEWAY. SEE SEC. 94-305 FOR | | | MORE INFORMATION OR REFER TO FIGURE X-1. | | | | | | 7. ZONING REVIEW 4.24.23 [NOT SATISFIED] | | | | | | [REPEAT COMMENT]: PLEASE NOTE FAR CALCULATIONS ARE THE | | | SAME AS GBA. PER SECTION 94-109. GROSS BUILDING AREA | | | MEANS THE TOTAL FLOOR AREA OF A BUILDING, INCLUDING | | | AIR- CONDITIONED OR FULLY ENCLOSED STORAGE SPACES, | | | ENCLOSED AREAS ON THE ROOFTOP, SUCH AS BATHROOMS AND | | | LOBBIES, STAIRS AND ELEVATOR AREAS, AND EXTERNAL | | | UNENCLOSED CIRCULATION AREAS. THE GROSS BUILDING AREA | | | DOES NOT INCLUDE PARKING AREAS; UNENCLOSED COLONNADES, | | | PORCHES AND BALCONIES; MECHANICAL AND ELECTRICAL | | | SPACES; AND TRASH ROOMS. STORAGE SPACES WITHOUT WINDOWS | | | AND ENCLOSED BY SURFACES THAT ALLOW FOR NATURAL | | | VENTILATION OR OUTSIDE AIR CIRCULATION SHALL NOT BE | | | INCLUDED. GROSS BUILDING AREA REQUIREMENTS: | | | 1. ANY PORTION OF THE PARKING AREA WHICH EXCEEDS THE | | | MAXIMUM PARKING RATIO SHALL BE INCLUDED IN THE | | | CALCULATIONS OF GROSS BUILDING AREA. THIS SHALL INCLUDE | | | STALLS AND ALL ASSOCIATED CIRCULATION AREAS. | | | 2. PARKING LOCATED BELOW GRADE SHALL NOT BE COUNTED AS | | | PART OF THE GROSS BUILDING AREA. | | | 3. THE GROSS BUILDING AREA SHALL BE MEASURED FROM THE | | | OUTSIDE FACE OF EXTERIOR WALLS. | | | | | | YOUR FAR CALCULATION NEEDS TO INCLUDE BOTH ELEVATORS | | | AND STAIRWELLS. | | | DATA TABLE AND FIGURES ON A0.04 APPEAR TO HAVE | | | DISCREPANCIES IN CALCULATIONS. IT IS STILL UNCLEAR TO | | | STAFF WHAT SPACES ARE COUNTING TOWARD TOTAL FAR AND | | | WHAT IS BEING OMITTED; DUE TO BEING A | | | MECHANICAL/ELECTRIC ROOM, OR PARKING. | | | STAFF RECOMMENDATION IS TO SIMPLIFY THE CALCULATIONS | | | TABLE INTO A SINGLE ONE RATHER THAN SPLITTING INTO TWO | | | COMPONENTS. | | | STAFF ALSO RECOMMENDS A SIMPLE TWO-TONED GRAPHIC FOR | | | FAR ON SHEET A0.04. | | | BLANK OR WHITE SPACE = AREAS NOT COUNTED TOWARD FAR | | | TOTAL | | | RED OR SOME OTHER COLOR = SPACE THAT IS COUNTED TOWARD | | | FAR TOTAL | | | | | | 8. ZONING REVIEW 4.20.23 [SATISFIED] | | | | | | 9. ZONING REVIEW 4.24.23 [PARTIALLY SATISFIED] | | | PREVIOUS 12.09.22 SUBMITTAL HAD SETBACKS ALONG DATURA | | | MEASURED FROM THE CENTER OF THE ON-STREET PARKING. | | | | | | WITHIN THIS 3.24.23 SUBMITTAL THE SETBACK IS BEING | | | MEASURED FROM THE BACK OF CURB, HOWEVER, THE | | | PREDOMINANT BACK OF CURB LINE IS THE INTERIOR CURB LINE | | | OF THE ON-STREET PARKING. PLEASE ADJUST. | | | SHEET A3.01 IS SHOWING TWO DIFFERENT SETBACKS ON THE | | | DATURA FRONTAGE. | | | SEE SEC. 94-109 SETBACK DEFINITION FOR MORE | | | INFORMATION. | | | | | | | | | 10. ZONING REVIEW 4.24.23 [SATISFIED] HISTORIC BUILDING | | | LEGAL NONCONFORMING, DOES NOT NEED TO MEET TRANSPARENCY | | | REQUIREMENTS. | | | | | | 11. ZONING REVIEW 4.24.23 [SATISFIED] RESTRICTIVE | | | COVENANT AND RECORDED DOCUMENTATION WILL BE A CONDITION | | | OF APPROVAL | | | | | | 12. ZONING REVIEW 4.24.23 [SATISFIED] | | | | | | 13. ZONING REVIEW 4.24.23 [SATISFIED] | | | | | | 14. ZONING REVIEW 4.24.23 [SATISFIED] | | | | | | 15. ZONING REVIEW 4.24.23 [SATISFIED] | | | | | | FROM 1.19.23 COMMENTS | | | 1. ZONING REVIEW 4.24.23 [SATISFIED] | | | | | | 2. ZONING REVIEW 4.24.23 [NOT SATISFIED] | | | ON SHEET A3.01 AND OTHERS THE BIKE RACKS ARE SHOWN | | | PARALLEL TO SIDEWALK, IS THE 8FT. CLEAR PATH MAINTAINED | | | WITH THE BIKES IN THIS POSITION? SHEET A0.6.2 SHOWS | | | UTILIZATION OF???INVERTED U??? RACKS, WITH THESE RACKS | | | THE BIKES ARE TYPICALLY PERPENDICULAR TO SIDEWALK AS IT | | | IS EASIER TO ACCESS FOR USERS. SPACES CAN BE PARALLEL | | | BUT RECOMMEND PLACING THEM ON A SEPARATE PAD WITHIN | | | LANDSCAPE BUFFER OR ANOTHER DEDICATED SPACE, AS THIS | | | MAINTAINS THE 8FT. CLEARANCE ON SIDEWALK. | | | MICROMOBILITY STATION AND STREETLIGHTS STILL APPEAR TO | | | OVERLAP STREET TREE LOCATIONS. | | | | | | 3. ZONING REVIEW 4.24.23 [NOT SATISFIED] | | | STREET TREE ON EITHER SIDE OF THE DRIVEWAY ALONG DATURA | | | STREET ARE NOT SPACED 30FT. APART. THERE IS THE WIDTH | | | OF THE DRIVEWAY AND THE MICROMOBILITY STATION | | | INTERRUPTING THE TREE CONTINUITY. PLEASE RECONFIGURE | | | TREES ON EITHER SIDE OF THE DRIVEWAY OR A VARIANCE MUST | | | BE REQUESTED AS IT DOES NOT MEET CODE PROVISION OF SEC. | | | 94-113(D.)(2.) | | | | | | 4. ZONING REVIEW 4.24.23 [NOT SATISFIED] ON THE NORTH | | | EASTERN CORNER OF PROJECT, THE STAIRWELL ENCROACHES | | | INTO THE SETBACK. PLEASE ADJUST TO BE OUTSIDE OF | | | REQUIRED 5FT. SETBACK. ALSO PLEASE REMOVE PLANTERS | | | WITHIN 5 FT. SETBACK, SHOULD BE HEDGES PLANTED AT 2-3 | | | FOOT INTERVALS AND SHADE TREES EVERY 30 FT. | | | | | | 5. ZONING REVIEW 4.24.23 [NOT SATISFIED] | | | PER SEC. 94-113(F.)(1.) A 5 FOOT LANDSCAPE BUFFER IS | | | NEEDED WITH SHRUBS PLANTED AT 2 OR 3 FT. INTERVALS AS | | | WELL AS SHADE TREES PLANTED AT 30 FT. INTERVALS. | | | SUBMITTED PLANS DO NOT SHOW SHADE TREES. PLEASE REMOVE | | | PLANTERS AND ENCROACHING STAIRWELL. | | | | | | ZONING COMMENTS 4.24.23: | | | | | | 1. PLEASE PROVIDE SIDEWALK AND CLEARPATH WIDTH FOR BOTH | | | DATURA AND S. DIXIE FRONTAGES. 8FT. CLEAR PATH REQUIRED | | | ON DATURA STREET FRONTAGE, SOUTH DIXIE HWY FRONTAGE TO | | | MAINTAIN EXISTING SIDEWALK WIDTH OR INCREASE COMPLIANCE | | | WITH REQUIRED 8FT. ALSO PROVIDE WIDTH OF LANDSCAPE | | | STRIP ALONG DATURA AND S DIXIE FRONTAGE. MICRO-MOBILITY | | | STATION CANNOT BE LOCATED WITHIN REQUIRED LANDSCAPE | | | STRIP ALONG DATURA FRONTAGE. | | | 2. PLEASE PROVIDE WIDTH OF DRIVEWAY OR CURBCUT WHERE IT | | | INTERSECTS WITH THE PROPERTY LINE, DIMENSION CANNOT | | | EXCEED 25FT. | | | 3. ON THE ELEVATION DRAWINGS, PLEASE PROVIDE HEIGHT OF | | | ROOFTOP ELEMENTS (TRELLIS, DECORATIVE ELEMENTS, ETC.), | | | EACH ELEMENT MUST MEET THE PROJECTION STANDARDS OF SEC. | | | 94-109 TABLE IV-5. | | | 4. PER SEC. 94-112 ALLEYS AND PUBLIC RIGHTS OF WAY: | | | INSTALLATION OF PUBLIC UTILITIES. ALL PROPOSED | | | DEVELOPMENTS EQUAL TO OR GREATER THAN 50,000 GROSS | | | SQUARE FEET SHALL HAVE ALL PUBLIC UTILITIES SERVICE | | | CONNECTIONS, INCLUDING TELEPHONE, CABLE AND ELECTRIC | | | DISTRIBUTION SERVICE INSTALLED UNDERGROUND. | | | 5. PLEASE WALLMOUNT FDC IF LOCATED ALONG DATURA | | | FRONTAGE, AND PROVIDE SOME LANDSCAPING OR SCREENING SO | | | LONG AS ACCESS IS NOT HINDERED. | | | 6. ON THE NORTH EASTERN CORNER OF PROJECT, THE | | | STAIRWELL ENCROACHES INTO THE SETBACK. PLEASE ADJUST TO | | | BE OUTSIDE OF REQUIRED 5FT. SETBACK. | | | 7. LANDSCAPE TERMINAL ISLANDS AND BUILDING BASE | | | PLANTING ON THE REAR SURFACE PARKING DOES NOT SEEM | | | VIABLE AS IT IS UNDER THE AMENITY DECK/ROOF, THESE | | | AREAS WILL NOT HAVE DIRECT SUNLIGHT OR OPEN-AIR ACCESS. | | | 8. ART IN PUBLIC PLACES CONTRIBUTION OR ART LOCATION ON | | | SITE MUST BE IDENTIFIED PRIOR TO TAKING THE SITE PLAN | | | TO DAC. | | | 9. LANDSCAPE PLANS CONFLICT WITH ARCHITECTURAL PLANS, | | | TREE LOCATIONS APPEAR TO DIFFER OR INTERFERE WITH SITE | | | ELEMENTS. BE SURE TO SHOW ON BOTH THE LANDSCAPE AND | | | ARCHITECTURE PLANS THE LOCATION OF ANY STREETSCAPE | | | ELEMENT (BIKERACK, LIGHTS, STREET TREES, FURNITURE, | | | METERS/VAULTS, PLANTERS, ETC.) | | | 10. PLEASE LIST AND IDENTIFY ANY ZONING VARIANCES THAT | | | ARE REQUESTED. | | | | | | | | | THERE ARE MANY OUTSTANDING ZONING COMMENTS POSSIBLY DUE | | | TO MISINTERPRETATION OR CONFUSION WITH CODE ELEMENTS | | | AND/OR SITE CHANGES FROM THE PREVIOUS SUBMITTAL HAS | | | OUTLINED OR CAUSED NEW COMMENTS. STAFF WOULD LIKE TO | | | SUGGEST AN IN-PERSON MEETING WITH THE APPLICANT/DESIGN | | | TEAM TO CLARIFY THE REMAINING ZONING COMMENTS SO THAT | | | THE NEXT SUBMITTAL MORE SUFFICIENTLY ADDRESSES COMMENTS | | | AND IS OKAYED FOR THE NEXT STEP IN THE DESIGN PROCESS | | | (DAC APPROVAL). | | | | | | CHRIS KIMMERLY, AICP | | | URBAN DESIGN PLANNER | | | [email protected] 561-822-1426 | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
01-24-2023 |
|
|
Cont ID |
|
| Sent By |
ckimmerl |
Date |
01-24-2023 |
Time |
11:42 |
Rev Time |
0.00 |
| Received By |
ckimmerl |
Date |
01-24-2023 |
Time |
11:41 |
Sent To |
|
|
| Notes |
| 2023-01-24 11:41:56 | DEVELOPMENT SERVICES DEPARTMENT | | | CHRIS KIMMERLY, URBAN DESIGN PLANNER | | | (561) 822-1426 | | | [email protected] | | | | | | 1.) BICYCLE PARKING NOT INCLUDED, PLEASE PROVIDE BIKE | | | SPACES MEETING THE REQUIRED STANDARDS: | | | A. 1 BIKE SPACE PER 15 PARKING SPACES? 12 SPACES WITHIN | | | BUILDING | | | B. 1 BIKE SPACE PER 100 FT. OF FRONTAGE? 3 SPACE ALONG | | | ROW/EXTERIOR | | | BIKE RACKS ARE SHOWN ON DATURA FRONTAGE, PLEASE PROVIDE | | | DETAILS AS TO THE SPACING BETWEEN RACKS AND THE TYPE OF | | | RACKS USE TO SECURE THE BIKES. PLEASE DETAIL THE | | | INTERNAL BIKE STORAGE ROOM FOR RESIDENTS, INCLUDE | | | DIMENSIONS, SPACING DETAILS, AND METHODS OF SECURING | | | BIKES. | | | RESPONSE: PLASE REFER TO SHEET A 1.00, , PROJECT DATA | | | WAS UPDATED TO SHOW THE NUMBER OF BICYCLE PARKING | | | SPACES PROVIDED FOR RESIDENTS IN THE PROJECT, SHEET | | | A0.6.2 INCLUDES DETAILS OF THE BICYCLE RACKS PROPOSED | | | IN THE PROJECT AND SHEET A3.01 SHOW THE LOCATION OF THE | | | RESIDENTS BICYCLE STORAGE AND STREET RACKS. | | | | | | ZONING 1/19/23: [NOT SATISFIED] SHEET A100 DATA TABLE | | | IS INCORRECTLY LABELED FOR THE PARKING SECTION. ZONING | | | IS CWD-10 (CWD 10-12 INCENTIVE DISTRICT). | | | | | | PARKING IS REQUIRED WITHIN THIS SUBDISTRICT AT THE | | | FOLLOWING RATIOS: | | | | | | RESIDENTIAL ??? MIN. 1 SPACE PER UNIT PLUS 1 SPACE PER | | | 20 UNITS FOR GUEST PARKING. MAX. IS 2 SPACES PER UNIT | | | PLUS 1 SPACE PER 20 UNITS FOR GUEST PARKING. | | | | | | RETAIL/COMMERCIAL/RESTAURANT ??? MIN. IS 2 SPACES PER | | | 1,000 SF. MAX. 4 SPACES PER 1,000 SF. FLOORS 3-12 | | | PROVIDE 140 UNITS, PARKING CALCULATION ONLY SPECIFIES | | | 95 SPACES PROVIDED, DOES NOT MEET MINIMUM. | | | | | | NOTE BICYCLE PARKING IS REQUIRED, 1 SPACE PER 100 | | | LINEAR FEET (LOCATION WITHIN ROW) | | | | | | PLEASE REVISE DATA TABLE TO CORRECTLY REFLECT REQUIRED | | | AND PROVIDED PARKING. | | | | | | 2. NO FACADE ARTICULATION SHEETS SHOWING COMPLIANCE TO | | | STANDARDS, PLEASE PROVIDE DETAILS ON FENESTRATION, | | | TRANSPARENCY, PLANAR BREAKS, ARCHITECTURAL TREATMENTS, | | | ETC. PLEASE REFERENCE SEC. 94-109 TABLE IV-4 FOR FACADE | | | ARTICULATION REQUIREMENTS. PLEASE PROVIDE ILLUSTRATIONS | | | SHOWING COMPLIANCE AND TABULAR CALCULATIONS SHOWING | | | COMPLIANCE. | | | RESPONSE: PLEASE REFER TO SHEETS A0.5.1 TO SHEET A0.5.8 | | | GRAPHIC AND TABULAR INFORMATION WAS INCLUDED TO SHOW | | | CODE COMPLIANCE WITH FENESTRATION, TRANSPARENCY AND | | | PLANAR BREAK REQUIREMETS. | | | ZONING 1/19/23: [NOT SATISFIED] PLEASE PROVIDE THE | | | ACTIVE USE CALCULATIONS AND TRANSPARENCY CALCULATIONS | | | FOR THE 120 S DIXIE BUILDING (HISTORICALLY ELIGIBLE | | | STRUCTURE) AS PART OF SHEET A0.5.3 AND A0.5.8. | | | | | | ON SHEET A0.5.5, A0.5.6, AND A0.5.7, THE TOWER PLANAR | | | BREAK DOES NOT APPLY TO THIS PROJECT, PLEASE REMOVE. | | | | | | REGARDING THE GROUND-PODIUM PLANAR BREAK (FLOORS 1-5) | | | PLEASE ADJUST THE CALCULATIONS AND AREA SHADED IN SHEET | | | A0.5.6 TO COUNT ONLY THE PORTIONS WHERE THE PRIMARY | | | FACE OR PLANE OF THE BUILDING IS INTERRUPTED BY A 3 FT. | | | + PROJECTION OR RECESSED AREA. PLEASE PROVIDE THE | | | DIMENSION OF THE DEPTH OF THE RECESS OR PROJECTION AS | | | WELL. | | | | | | REQUIREMENTS APPEAR TO BE MET, THE GRAPHIC | | | REPRESENTATION OR TOTAL CALCULATIONS ARE INCORRECT. | | | | | | 3. PRIVATE OPEN SPACE REQUIREMENT IS 25% OF LOT AREA, | | | REQUIRING 9,788SF. PLEASE INDICATE WHERE THIS SPACE IS | | | PROVIDED ON THE PLANS, IS THE TERRACE MEETING THIS | | | REQUIREMENT? PLEASE BE SURE TO LABEL AND INCLUDE THE | | | PERMITTED PRIVATE OPEN SPACES PER SEC. 94-109 TABLE | | | IV-6 AND TABLE IV-7. PROPERLY LABEL THE TYPE OF PRIVATE | | | OPEN SPACE PROVIDED AND BE SURE TO DETAIL HOW THE | | | REQUIREMENTS ARE MET. | | | RESPONSE: PLEASE REFER TO SHEETS A0.03, PRIVATE OPENS | | | SPACE CALCULATION DIAGRAM WAS ADDED. | | | ZONING 1/19/23: [NOT SATISFIED] PLEASE PROVIDE ON SHEET | | | A0.03 THE CALCULATION AND BREAKDOWN OF THE PRIVATE OPEN | | | SPACE REQUIRED AND PROVIDED: | | | | | | I.E. REQUIRED 25% LOT AREA = 9810SF, 30% VEGETATED = | | | 2,943, MAX. 30% OVERHEAD COVER, AND TREE CANOPY 20%. | | | THEN PROVIDE THE ACTUAL COUNT PROVIDED FOR EACH. | | | | | | 4. SHEET A2.00, DOES NOT ACCURATELY REFLECT CURRENT | | | STREETSCAPE CONDITIONS ALONG S. DIXIE HIGHWAY, THERE | | | ARE TWO EXISTING ON-STREET PARKING SPACES ALONG THE | | | WESTERN SIDE OF THE ROAD. | | | RESPONSE: SITE PLAN WAS UPDATED TO REFLECT CURRENT | | | STREETSCAPE CONDITIONS ALONG S. DIXIE HIGHWAY | | | ZONING 1/19/23: [SATISFIED] | | | | | | 5. SHEET A2.00 ILLUSTRATES A PROPOSED ON-STREET DROP | | | OFF, STAFF DOES NOT SUPPORT THE INCLUSION OF THIS | | | ON-STREET DROP-OFF AS THERE IS NOT ADEQUATE SPACE TO | | | PROVIDE FOR THE REQUIRED STREETSCAPE LANDSCAPING AND AN | | | 8FT. CLEAR SIDEWALK. | | | RESPONSE: PLEASE REFER TO SHEET A200 AND A301, STREET | | | DROP OFF WAS REMOVED FROM DIXIE HWY. | | | ZONING 1/19/23: [SATISFIED] | | | | | | 6. PLEASE ILLUSTRATE SITE VISIBILITY TRIANGLES FROM THE | | | DRIVEWAY ACCESS, STAFF WOULD LIKE TO VERIFY THERE ARE | | | NO OBSTRUCTIONS. | | | RESPONSE: PLEASE REFER TO SHEET A301, VISIBILITY | | | TRIANGLES WERE ADDED TO THE DRIVEWAY ACCESS AND NOTE | | | INDICATING HEIGHT OF THE PLANTERS AND GLASS HANDRAIL | | | PROPOSED ON THE EMERGENCY EXIT STAIR. | | | ZONING 1/19/23: [SATISFIED] | | | | | | NOTE: SITE VISIBILITY CAN BE ADJUSTED TO BE FROM THE | | | PROPERTY LINE INTERSECTION WITH THE DRIVEWAY. SEE SEC. | | | 94-305 FOR MORE INFORMATION OR REFER TO FIGURE X-1. | | | | | | 7. PLEASE INCLUDE AN FAR DIAGRAM, ILLUSTRATING WHICH | | | ROOMS ARE COUNTED TOWARD FAR AND THOSE THAT ARE NOT. | | | PLEASE ALSO PROVIDE A TABULAR BREAKDOWN OF THESE SPACES | | | AND FAR CALCULATIONS. SHEET A0.04 SEEMS TO PROVIDE SOME | | | DETAIL BUT IT IS NOT CLEAR AS TO WHAT IS OR ISN???T | | | COUNTED. THE COLOR COORDINATION IS NOT CLEAR. PLEASE | | | NOTE FAR CALCULATIONS ARE THE SAME AS GBA. PER SECTION | | | 94-109. GROSS BUILDING AREA MEANS THE TOTAL FLOOR AREA | | | OF A BUILDING, INCLUDING AIR-CONDITIONED OR FULLY | | | ENCLOSED STORAGE SPACES, ENCLOSED AREAS ON THE ROOFTOP, | | | SUCH AS BATHROOMS AND LOBBIES, STAIRS AND ELEVATOR | | | AREAS, AND EXTERNAL UNENCLOSED CIRCULATION AREAS. THE | | | GROSS BUILDING AREA DOES NOT INCLUDE PARKING AREAS; | | | UNENCLOSED COLONNADES, PORCHES AND BALCONIES; | | | MECHANICAL AND ELECTRICAL SPACES; AND TRASH ROOMS. | | | STORAGE SPACES WITHOUT WINDOWS AND ENCLOSED BY SURFACES | | | THAT ALLOW FOR NATURAL VENTILATION OR OUTSIDE AIR | | | CIRCULATION SHALL NOT BE INCLUDED. GROSS BUILDING AREA | | | REQUIREMENTS: | | | | | | 1. ANY PORTION OF THE PARKING AREA WHICH EXCEEDS THE | | | MAXIMUM PARKING RATIO SHALL BE INCLUDED IN THE | | | CALCULATIONS OF GROSS BUILDING AREA. THIS SHALL INCLUDE | | | STALLS AND ALL ASSOCIATED CIRCULATION AREAS. | | | 2. PARKING LOCATED BELOW GRADE SHALL NOT BE COUNTED AS | | | PART OF THE GROSS BUILDING AREA. | | | 3. THE GROSS BUILDING AREA SHALL BE MEASURED FROM THE | | | OUTSIDE FACE OF EXTERIOR WALLS. | | | RESPONSE: PLEASE REFER TO SHEETS A0.04.2 INFORMATION | | | RELATED TO FAR CALCULATIONS WAS INCLUDED. | | | | | | ZONING 1/19/23: [NOT SATISFIED] FAR CALCULATION DOES | | | INCLUDE ELEVATOR WELLS AND STAIRCASES. FAR CALCULATION | | | IS BASED UPON THE STANDARDS WITHIN THE DEFINITION FOR | | | GROSS BUILDING AREA ??? SEC. 94-109. PLEASE REVISE | | | CALCULATIONS. | | | | | | PLEASE PROVIDE THE FAR FOR THE HISTORICALLY ELIGIBLE | | | STRUCTURE AS WELL, THIS BUILDING COUNTS TOWARDS THE | | | TOTAL DEVELOPMENT CALCULATION FOR THE ENTIRE PROJECT | | | SITE/LOT. PLEASE BE SURE THIS GROSS BUILDING AREA AND | | | FAR IS INCLUDED ON SHEET A100. | | | | | | 8. BECAUSE THE PROJECT IS SEEKING TO UTILIZE TDRS AND | | | THE HEIGHT/FAR INCENTIVE, PER SECTION. 94-131 ELIGIBLE | | | HISTORIC STRUCTURES LOCATED WITHIN THE SUBJECT SITE ARE | | | PRESERVED ACCORDING TO THE SECRETARY OF INTERIOR | | | STANDARDS, AND INTEGRATED AS PART OF THE NEW | | | DEVELOPMENT IN A MANNER WHICH MAINTAINS THE INTEGRITY | | | OF THE HISTORIC STRUCTURE. AS SUCH, PLEASE INCLUDE | | | PLANS, DETAILS, ELEVATIONS, AND ANY | | | IMPROVEMENTS/RENOVATIONS TO THE DATURA STATION | | | BUILDING. | | | RESPONSE: PLEASE REFER TO SHEETS A0.7.1 A NEW SHEET WAS | | | INCLUDED DESCRIBING THE SCOPE OF IMPROVEMENTS TO THE | | | HISTORINC BUILDING. | | | ZONING 1/19/23: [SATISFIED] | | | | | | 9. PLEASE OVERLAY AND PROVIDE SETBACK LINES ON SITE | | | PLANS, FLOOR PLANS, AND ELEVATION DRAWINGS. | | | RESPONSE: ALL DRAWINGS WERE UPDATED TO SHOW PROPERTY | | | LINE AND SETBACKS IN BOTH FLOOR PLANS AND ELEVATIONS | | | DRAWINGS | | | ZONING 1/19/23: [PARTIALLY SATISFIED] SETBACKS SHOWN ON | | | DRAWINGS, HOWEVER GROUND FLOOR SETBACK ALONG DATURA | | | INCORRECTLY MEASURED. SETBACK IS FROM THE BACK OF THE | | | CURB. PLANS SHOW FROM INSIDE ON-STREET PARKING. SHEET | | | A2.00, SHEET A3.01, SHEET A4.02, SHEET A4.03, | | | | | | 10. PLEASE PROVIDE ACTIVE USE DIAGRAMS AND TABULAR | | | CALCULATIONS, PLEASE NOTE PER SEC. 94-109: ACTIVE USE | | | MEANS A USE WITHIN AN ENCLOSED BUILDING DESIGNED FOR | | | HUMAN OCCUPATION WITH A DIRECT VIEW TO ADJACENT STREETS | | | OR PUBLIC OPEN SPACE. ACTIVE USE REQUIREMENTS: | | | 1. ACTIVE USES ARE REGULATED AS A PERCENTAGE OF THE | | | BUILDABLE LOT FRONTAGE. IN THOSE CASES WHERE PUBLIC | | | OPEN SPACE IS PROVIDED ALONG THE FRONTAGE LINE, THE | | | OPEN SPACE MAY BE COUNTED AS ACTIVE USE AS LONG AS | | | ACTIVE USES ARE PROVIDED ON THE FIRST FLOOR OF THE | | | BUILDING ADJOINING THE PUBLIC OPEN SPACE. | | | | | | RESIDENTIAL AMENITIES NOT INTENDED TO ATTRACT | | | PEDESTRIAN ACTIVITY SHALL NOT BE PERMITTED TO COUNT AS | | | THE MINIMUM ACTIVE USE REQUIREMENT IN THE GROUND FLOOR | | | ALONG PRIMARYPEDESTRIAN STREETS, UNLESS OPEN TO THE | | | GENERAL PUBLIC. SUCH AMENITIES INCLUDE, BUT ARE NOT | | | LIMITED TO GYMS, MOVIE ROOMS, AND YOGA ROOMS. | | | RESPONSE: PLEASE REFER TO SHEET A0.5.8 GRAPHIC AND | | | TABULAR INFORMATION WAS INCLUDED TO SHOW CODE | | | COMPLIANCE. | | | ZONING 1/19/23: [PARTIALLY SATISFIED] PLEASE INCLUDE | | | THE HISTORIC BUILDING WITHIN THE ACTIVE USE | | | CALCULATIONS FOR THE DATURA ST. FRONTAGE AND PROVIDE | | | THE S DIXIE HWY ACTIVE USE CALCULATIONS AS WELL. PLEASE | | | CLARIFY WITHIN THE TABULAR DATA THE LINEAR LENGTH OF | | | ACTIVE FRONTAGE AND THE PERCENTAGE, CURRENTLY ONLY | | | SHOWS THE TRANSPARENCY AND PERCENTAGE. | | | | | | 11. DUE TO THE INCLUSION OF STACKERS, PER SEC. 94-111 | | | (K.): MECHANICAL AND AUTOMATED PARKING. PARKING | | | STRUCTURES WITH MECHANICAL PARKING SHALL PROVIDE A | | | COMMERCIAL ATTENDANT DURING THE OPERATING HOURS OF THE | | | FACILITY. SUCH OPERATION SHALL BE ENFORCED THROUGH A | | | RESTRICTIVE COVENANT RECORDED IN THE PUBLIC RECORDS. | | | ALL RESTRICTIVE COVENANTS AND OTHER DOCUMENTS REQUIRED | | | TO BE RECORDED SHALL BE ON CITY APPROVED FORMS, AND | | | RECORDED IN THE PUBLIC RECORDS. | | | | | | PLEASE PROVIDE DETAIL OF THE STACKERS. | | | RESPONSE: PLEASE REFER TO SHEET A300, STACKERS WERE | | | REMOVED FROM THE PARKING GARAGE AND NO COMMERCIAL | | | ATTENDANT WILL BE REQUIRED. | | | ZONING 1/19/23: [SATISFIED] | | | RESTRICTIVE COVENANT AND RECORDED DOCUMENTATION WILL BE | | | A CONDITION OF APPROVAL. | | | | | | 12. PLEASE PROVIDE PARKING STRIPING AND DIMENSION | | | DETAIL PER FIGURE XV-2 IN SECTION 94-485 | | | RESPONSE: PLEASE REFER TO SHEET A0.6.0, A300, A301, | | | PARKING SPACE DETAIL WAS ADDED TO SHOW PARKING SPACES | | | DIMS AND STRIPING DETAIL AS PER SEC.94-485, FIG. XV-2 | | | ZONING 1/19/23: [SATISFIED] | | | | | | 13. FOR RESIDENTIAL USES, TANDEM PARKING, IF PROVIDED, | | | MAY COUNT AS TWO SPACES, PROVIDED BOTH SPACES ARE | | | DEDICATED TO THE SAME RESIDENTIAL UNIT, AND A | | | RESTRICTIVE COVENANT IS RECORDED ON CITY APPROVED | | | FORMS, AND RECORDED IN THE PUBLIC RECORDS. | | | RESPONSE: NOTED | | | ZONING 1/19/23: [SATISFIED] | | | | | | 14. ELEVATION DRAWINGS SHOW THE PARKING RAMPS AT 16%. | | | PARKING RAMP MAXIMUM SLOPE. MAXIMUM SLOPES FOR PARKING | | | RAMPS SHALL BE IN ACCORDANCE WITH ADA REQUIREMENTS AND | | | SHALL NOT EXCEED SIX PERCENT. NON-PARKING RAMPS SHALL | | | NOT EXCEED 16 PERCENT. IF THE RAMP IS GREATER THAN 14 | | | PERCENT, A BREAK-OVER TRANSITION SHALL BE REQUIRED. THE | | | PREFERRED STANDARD IS TEN PERCENT FOR NON-PARKING RAMP | | | SLOPES. | | | RESPONSE: PLEASE REFER TO SHEETS A300, A301, A500, A | | | 501, NOTES INDICATING THE RAMP BREAK AT THE BEGINNING | | | AND THE END OF THE RAMP WERE INCLUDED (RAMP TRANSITION | | | ??) | | | ZONING 1/19/23: [SATISFIED] | | | | | | | | | 15. PLEASE ILLUSTRATE THE BREAK-OVER TRANSITION SPACE. | | | RESPONSE: PLEASE REFER TO SHEETS A300, A301, A500 AND | | | A501, A NOTE INDICATING THE RAMP TRANSITIONS AT THE | | | BEGINNING AND END PORTION WAS INCLUDED. | | | ZONING 1/19/23: [SATISFIED] | | | | | | ZONING 1.19.23 ??? NEW COMMENTS: | | | | | | 1. THE HISTORICALLY ELIGIBLE STRUCTURE FRONTING DIXIE | | | MUST BE INCLUDED WITHIN ALL BUILDING REQUIREMENT AND | | | SITE CALCULATIONS. INCLUDING BUT NOT LIMITED TO: FAR, | | | BUILDING FOOTPRINT, LOT COVERAGE, GROSS BUILDING AREA, | | | AND PARKING CALCULATIONS. BE SURE TO UPDATE ALL | | | ACCOMPANYING SHEETS AND DATA TABLES. | | | | | | 2. ON SHEET A2.00 PLEASE ADDRESS GRAPHIC ISSUES WITH | | | MICROMOBILITY AND BIKE RACKS LOCATED WITHIN TREES, | | | PLEASE CLARIFY WHAT THE SQUARE ITEMS ARE BETWEEN THE | | | TREES AND WITHIN THE LANDSCAPE STRIP (ARE THESE | | | TREEGRATES OR CONCRETE PADS FOR THE BIKES?) | | | | | | 3. STREETSCAPE ALONG DATURA STREET DOES NOT APPEAR TO | | | MEET THE MAXIMUM SPACING OF TREES PER SEC. | | | 94-113(D.)(2.) MAXIMUM ALLOWED IS 30 FT. ON CENTER. | | | TREES ON EITHER SIDE OF DRIVEWAY APPEAR TO EXCEED 30 | | | FT. | | | | | | 4. ON SHEET A2.00 AND A3.01, PLEASE CLARIFY HOW THE | | | SURFACE PARKING ON THE GROUND LEVEL WORKS? IT APPEARS | | | THAT THERE ARE STRUCTURAL COLUMNS OR POSTS WITHIN THE | | | 5??? REAR SETBACK. PLEASE PROVIDE DETAILS OF THE | | | OVERHEAD TRELLIS STRUCTURE. | | | | | | 5. PER SEC. 94-113(F.) SURFACE PARKING LOTS. ALL | | | OFF-STREET SURFACE PARKING LOTS SHALL MEET THE | | | FOLLOWING LANDSCAPING REQUIREMENTS: | | | | | | A) SETBACKS AND LANDSCAPE BUFFER. SURFACE PARKING LOTS | | | SHALL MEET THE MINIMUM GROUND FLOOR SETBACK | | | REQUIREMENTS AS PROVIDED IN THE SUBDISTRICT BUILDING | | | REQUIREMENTS TABLE. A FIVE-FOOT LANDSCAPE BUFFER SHALL | | | BE PROVIDED IN ADDITION TO THE GROUND FLOOR SETBACK TO | | | VISUALLY SCREEN PARKING AREAS. THE LANDSCAPE BUFFER | | | SHALL BE COMPRISED OF A HEDGE PLANTED AT TWO-FOOT TO | | | THREE-FOOT INTERVALS AND MAINTAINED AT A MAXIMUM HEIGHT | | | OF 36 INCHES AT MATURITY. SHADE TREES SHALL BE PLANTED | | | AT 30-FOOT INTERVALS. A FIVE-FOOT LANDSCAPE BUFFER | | | SHALL ALSO BE PROVIDED MEETING THESE REQUIREMENTS FOR | | | THE ENTIRE PERIMETER OF THE SURFACE LOT. SURFACE | | | PARKING AREAS LOCATED BEHIND BUILDINGS ARE EXEMPT FROM | | | THE FRONT SETBACK LANDSCAPE REQUIREMENTS. | | | | | | B) TERMINAL ISLANDS, INTERIOR ISLANDS AND DIVIDER | | | MEDIANS. ALL OTHER PARKING AREA LANDSCAPING SHALL MEET | | | THE REQUIREMENTS OF CHAPTER XIV. | | | | | | PLEASE REVISE PLANS TO PROVIDE THE 5??? LANDSCAPE | | | BUFFER FOR PARKING. | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
10-13-2022 |
|
|
Cont ID |
|
| Sent By |
ckimmerl |
Date |
10-13-2022 |
Time |
12:16 |
Rev Time |
0.00 |
| Received By |
ckimmerl |
Date |
10-13-2022 |
Time |
12:15 |
Sent To |
|
|
| Notes |
| 2022-10-13 12:15:59 | 1. BICYCLE PARKING NOT INCLUDED, PLEASE PROVIDE BIKE | | | SPACES MEETING THE REQUIRED STANDARDS: | | | A. 1 BIKE SPACE PER 15 PARKING SPACES ??? 12 SPACES | | | WITHIN BUILDING | | | B. 1 BIKE SPACE PER 100 FT. OF FRONTAGE ??? 3 SPACE | | | ALONG ROW/EXTERIOR | | | | | | BIKE RACKS ARE SHOWN ON DATURA FRONTAGE, PLEASE PROVIDE | | | DETAILS AS TO THE SPACING BETWEEN RACKS AND THE TYPE OF | | | RACKS USE TO SECURE THE BIKES. PLEASE DETAIL THE | | | INTERNAL BIKE STORAGE ROOM FOR RESIDENTS, INCLUDE | | | DIMENSIONS, SPACING DETAILS, AND METHODS OF SECURING | | | BIKES. | | | | | | 2. NO FA??ADE ARTICULATION SHEETS SHOWING COMPLIANCE TO | | | STANDARDS, PLEASE PROVIDE DETAILS ON FENESTRATION, | | | TRANSPARENCY, PLANAR BREAKS, ARCHITECTURAL TREATMENTS, | | | ETC. PLEASE REFERENCE SEC. 94-109 TABLE IV-4 FOR | | | FA??ADE ARTICULATION REQUIREMENTS. PLEASE PROVIDE | | | ILLUSTRATIONS SHOWING COMPLIANCE AND TABULAR | | | CALCULATIONS SHOWING COMPLIANCE. | | | | | | 3. PRIVATE OPEN SPACE REQUIREMENT IS 25% OF LOT AREA, | | | REQUIRING 9,788SF. PLEASE INDICATE WHERE THIS SPACE IS | | | PROVIDED ON THE PLANS, IS THE TERRACE MEETING THIS | | | REQUIREMENT? PLEASE BE SURE TO LABEL AND INCLUDE THE | | | PERMITTED PRIVATE OPEN SPACES PER SEC. 94-109 TABLE | | | IV-6 AND TABLE IV-7. PROPERLY LABEL THE TYPE OF PRIVATE | | | OPEN SPACE PROVIDED AND BE SURE TO DETAIL HOW THE | | | REQUIREMENTS ARE MET. | | | | | | 4. SHEET A2.00, DOES NOT ACCURATELY REFLECT CURRENT | | | STREETSCAPE CONDITIONS ALONG S. DIXIE HIGHWAY, THERE | | | ARE TWO EXISTING ON-STREET PARKING SPACES ALONG THE | | | WESTERN SIDE OF THE ROAD. | | | | | | 5. SHEET A2.00 ILLUSTRATES A PROPOSED ON-STREET DROP | | | OFF, STAFF DOES NOT SUPPORT THE INCLUSION OF THIS | | | ON-STREET DROP-OFF AS THERE IS NOT ADEQUATE SPACE TO | | | PROVIDE FOR THE REQUIRED STREETSCAPE LANDSCAPING AND AN | | | 8FT. CLEAR SIDEWALK. | | | | | | 6. PLEASE ILLUSTRATE SITE VISIBILITY TRIANGLES FROM THE | | | DRIVEWAY ACCESS, STAFF WOULD LIKE TO VERIFY THERE ARE | | | NO OBSTRUCTIONS. | | | | | | 7. PLEASE INCLUDE AN FAR DIAGRAM, ILLUSTRATING WHICH | | | ROOMS ARE COUNTED TOWARD FAR AND THOSE THAT ARE NOT. | | | PLEASE ALSO PROVIDE A TABULAR BREAKDOWN OF THESE SPACES | | | AND FAR CALCULATIONS. SHEET A0.04 SEEMS TO PROVIDE SOME | | | DETAIL BUT IT IS NOT CLEAR AS TO WHAT IS OR ISN???T | | | COUNTED. THE COLOR COORDINATION IS NOT CLEAR. | | | PLEASE NOTE FAR CALCULATIONS ARE THE SAME AS GBA. PER | | | SECTION 94-109. | | | GROSS BUILDING AREA MEANS THE TOTAL FLOOR AREA OF A | | | BUILDING, INCLUDING AIR-CONDITIONED OR FULLY ENCLOSED | | | STORAGE SPACES, ENCLOSED AREAS ON THE ROOFTOP, SUCH AS | | | BATHROOMS AND LOBBIES, STAIRS AND ELEVATOR AREAS, AND | | | EXTERNAL UNENCLOSED CIRCULATION AREAS. THE GROSS | | | BUILDING AREA DOES NOT INCLUDE PARKING AREAS; | | | UNENCLOSED COLONNADES, PORCHES AND BALCONIES; | | | MECHANICAL AND ELECTRICAL SPACES; AND TRASH ROOMS. | | | STORAGE SPACES WITHOUT WINDOWS AND ENCLOSED BY SURFACES | | | THAT ALLOW FOR NATURAL VENTILATION OR OUTSIDE AIR | | | CIRCULATION SHALL NOT BE INCLUDED. | | | GROSS BUILDING AREA REQUIREMENTS: | | | | | | 1. ANY PORTION OF THE PARKING AREA WHICH EXCEEDS THE | | | MAXIMUM PARKING RATIO SHALL BE INCLUDED IN THE | | | CALCULATIONS OF GROSS BUILDING AREA. THIS SHALL INCLUDE | | | STALLS AND ALL ASSOCIATED CIRCULATION AREAS. | | | 2. PARKING LOCATED BELOW GRADE SHALL NOT BE COUNTED AS | | | PART OF THE GROSS BUILDING AREA. | | | 3. THE GROSS BUILDING AREA SHALL BE MEASURED FROM THE | | | OUTSIDE FACE OF EXTERIOR WALLS. | | | | | | | | | 8. BECAUSE THE PROJECT IS SEEKING TO UTILIZE TDRS AND | | | THE HEIGHT/FAR INCENTIVE, PER SECTION. 94-131 ELIGIBLE | | | HISTORIC STRUCTURES LOCATED WITHIN THE SUBJECT SITE ARE | | | PRESERVED ACCORDING TO THE SECRETARY OF INTERIOR | | | STANDARDS, AND INTEGRATED AS PART OF THE NEW | | | DEVELOPMENT IN A MANNER WHICH MAINTAINS THE INTEGRITY | | | OF THE HISTORIC STRUCTURE. | | | AS SUCH, PLEASE INCLUDE PLANS, DETAILS, ELEVATIONS, AND | | | ANY IMPROVEMENTS/RENOVATIONS TO THE DATURA STATION | | | BUILDING. | | | | | | 9. PLEASE OVERLAY AND PROVIDE SETBACK LINES ON SITE | | | PLANS, FLOOR PLANS, AND ELEVATION DRAWINGS. | | | | | | 10. PLEASE PROVIDE ACTIVE USE DIAGRAMS AND TABULAR | | | CALCULATIONS, PLEASE NOTE PER SEC. 94-109: | | | ACTIVE USE MEANS A USE WITHIN AN ENCLOSED BUILDING | | | DESIGNED FOR HUMAN OCCUPATION WITH A DIRECT VIEW TO | | | ADJACENT STREETS OR PUBLIC OPEN SPACE. | | | ACTIVE USE REQUIREMENTS: | | | 1. ACTIVE USES ARE REGULATED AS A PERCENTAGE OF THE | | | BUILDABLE LOT FRONTAGE. IN THOSE CASES WHERE PUBLIC | | | OPEN SPACE IS PROVIDED ALONG THE FRONTAGE LINE, THE | | | OPEN SPACE MAY BE COUNTED AS ACTIVE USE AS LONG AS | | | ACTIVE USES ARE PROVIDED ON THE FIRST FLOOR OF THE | | | BUILDING ADJOINING THE PUBLIC OPEN SPACE. | | | | | | RESIDENTIAL AMENITIES NOT INTENDED TO ATTRACT | | | PEDESTRIAN ACTIVITY SHALL NOT BE PERMITTED TOCOUNT AS | | | THE MINIMUM ACTIVE USE REQUIREMENT IN THE GROUND FLOOR | | | ALONG PRIMARYPEDESTRIAN STREETS, UNLESS OPEN TO THE | | | GENERAL PUBLIC. SUCH AMENITIES INCLUDE, BUT ARE | | | NOTLIMITED TO GYMS, MOVIE ROOMS, AND YOGA ROOMS. | | | | | | 11. DUE TO THE INCLUSION OF STACKERS, PER SEC. 94-111 | | | (K.): MECHANICAL AND AUTOMATED PARKING. PARKING | | | STRUCTURES WITH MECHANICAL PARKING SHALL PROVIDE A | | | COMMERCIAL ATTENDANT DURING THE OPERATING HOURS OF THE | | | FACILITY. SUCH OPERATION SHALL BE ENFORCED THROUGH A | | | RESTRICTIVE COVENANT RECORDED IN THE PUBLIC RECORDS. | | | ALL RESTRICTIVE COVENANTS AND OTHER DOCUMENTS REQUIRED | | | TO BE RECORDED SHALL BE ON CITY APPROVED FORMS, AND | | | RECORDED IN THE PUBLIC RECORDS. | | | | | | PLEASE PROVIDE DETAIL OF THE STACKERS. | | | | | | 12. PLEASE PROVIDE PARKING STRIPING AND DIMENSION | | | DETAIL PER FIGURE XV-2 IN SECTION 94-485 | | | | | | 13. FOR RESIDENTIAL USES, TANDEM PARKING, IF PROVIDED, | | | MAY COUNT AS TWO SPACES, PROVIDED BOTH SPACES ARE | | | DEDICATED TO THE SAME RESIDENTIAL UNIT, AND A | | | RESTRICTIVE COVENANT IS RECORDED ON CITY APPROVED | | | FORMS, AND RECORDED IN THE PUBLIC RECORDS. | | | | | | 14. ELEVATION DRAWINGS SHOW THE PARKING RAMPS AT 16%. | | | PARKING RAMP MAXIMUM SLOPE. MAXIMUM SLOPES FOR PARKING | | | RAMPS SHALL BE IN ACCORDANCE WITH ADA REQUIREMENTS AND | | | SHALL NOT EXCEED SIX PERCENT. NON-PARKING RAMPS SHALL | | | NOT EXCEED 16 PERCENT. IF THE RAMP IS GREATER THAN 14 | | | PERCENT, A BREAK-OVER TRANSITION SHALL BE REQUIRED. THE | | | PREFERRED STANDARD IS TEN PERCENT FOR NON-PARKING RAMP | | | SLOPES. | | | | | | PLEASE ILLUSTRATE THE BREAK-OVER TRANSITION SPACE. | | | | | | | | | CHRIS KIMMERLY, AICP | | | URBAN DESIGN PLANNER | | | 822-1426 [email protected] | | | |
|
|
| |
Print |
|
Account Summary | Usage Policy | Privacy Policy