Plan Review Details - Project Z22090013
| Plan Review Stops For Project Z22090013 |
| Review Stop |
AIPP |
ART IN PUBLIC PLACES |
| Rev No |
1 |
Status |
P |
Date |
10-31-2022 |
|
|
Cont ID |
|
| Sent By |
swelter |
Date |
10-11-2022 |
Time |
13:23 |
Rev Time |
0.00 |
| Received By |
swelter |
Date |
10-31-2022 |
Time |
16:15 |
Sent To |
|
|
| Notes |
| 2022-10-11 13:42:45 | | | | POTENTIAL SITE IDENTIFIED ON SITE PLAN - MEETS PUBLIC | | | ART LOCATION REQUIREMENT | | | | | | SUBJECT TO PUBLIC ART REQUIREMENT - PLACE HOLDER FOR | | | PUBLIC ART SHOULD BE IDENTIFIED ON ALL SITE PLANS. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
11-07-2022 |
|
|
Cont ID |
|
| Sent By |
rbrown |
Date |
11-07-2022 |
Time |
15:50 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
11-07-2022 |
Time |
15:50 |
Sent To |
|
|
| Notes |
| 2022-11-07 15:53:55 | DEVELOPMENT SERVICES DEPARTMENT, BUILDING DIVISION, | | | COMMENTS: | | | | | | 1. THIS REVIEW IS A CURSORY REVIEW AS IT RELATES TO THE | | | SITE. IT IS NOT A REVIEW FOR FULL COMPLIANCE WITH | | | FLORIDA BUILDING CODE. THE FOLLOWING COMMENTS ARE TO BE | | | ADDRESSED FOR THE BUILDING PERMIT APPLICATION. | | | | | | 2. INFORMATIONAL: DEMOLITION OF THE EXISTING BUILDINGS. | | | AN ASBESTOS SURVEY SHALL BE PERFORMED AND AN ASBESTOS | | | ABATEMENT REPORT SUBMITTED TO THE HEALTH DEPARTMENT | | | PALM BEACH COUNTY OFFICE. CONTACT ALEX ORTEGA AT (561) | | | 837-5963, OR BY EMAIL: [email protected] | | | | | | 3. INFORMATIONAL: BUILDING SIZE. WHEN SUBMITTED FOR | | | BUILDING PERMIT, THE PLANS SHALL SHOW THAT THE TYPE OF | | | CONSTRUCTION FOR THE BUILDINGS WILL BE IN ACCORDANCE | | | WITH THE HEIGHT, AREA AND OCCUPANCY LIMITATIONS IN | | | CHAPTER 5 OF THE FLORIDA BUILDING CODE. | | | | | | 4. INFORMATIONAL: BUILDING LOCATION RELATIVE TO THE | | | PROPERTY LINE AND OTHER STRUCTURES. WHEN SUBMITTED FOR | | | BUILDING PERMIT, COMPLIANCE WITH ALL BUILDING | | | SEPARATION, PERCENTAGE OF OPENINGS AND OPENING | | | PROTECTIVE REQUIREMENTS OF CHAPTERS 6 AND 7 OF THE | | | FLORIDA BUILDING CODE SHALL BE VERIFIED. | | | | | | 5. INFORMATIONAL: ENCLOSED PARKING GARAGES. IF THE | | | PARKING GARAGE DOES NOT HAVE WALL OPENINGS, OR | | | SUFFICIENT WALL OPENINGS TO MEET THE DEFINITION OF AN | | | OPEN PARKING GARAGE, IT WILL BE CONSIDERED AN ENCLOSED | | | PARKING GARAGE AND MUST HAVE EXHAUST SYSTEMS. THE | | | EXHAUST SYSTEMS SHALL BE DESIGNED TO MINIMIZE NOISE | | | LEVELS USING INLINE FAN SILENCERS OR OTHER APPROVED | | | METHODS. | | | | | | 6. INFORMATIONAL: SEPARATE PERMITS REQUIRED. ALL | | | APPLICABLE PERMITS AND SUB-PERMITS MUST BE OBTAINED | | | BEFORE COMMENCING THE WORK. SEPARATE PERMITS, PLANS AND | | | FEES, ARE REQUIRED FOR SIGNS, SWIMMING POOLS AND SPAS, | | | GAS SYSTEMS, GENERATORS, FIRE ALARM SYSTEMS, FIRE | | | SPRINKLER AND OTHER FIRE SUPPRESSION SYSTEMS, GREASE | | | INTERCEPTORS, SITE LIGHTING, SITE LANDSCAPE, SITE | | | IRRIGATION, ETC. | | | | | | 7. INFORMATIONAL: CONTRACTOR VEHICLE PARKING. PROPERTY | | | OWNER AND CONTRACTOR SHALL MAKE ARRANGEMENTS FOR | | | PARKING OF CONTRACTOR VEHICLES TO MINIMIZE THE IMPACT | | | ON ALL NEIGHBORING PROPERTIES. | | | | | | 8. INFORMATIONAL: PROTECTION OF NEIGHBORING PROPERTY. | | | PROPERTY OWNER AND CONTRACTOR SHALL PROTECT ALL | | | NEIGHBORING PROPERTY, INCLUDING VEHICLES, FROM DAMAGE | | | OR DIRT CAUSED BY THE CONSTRUCTION, AND SHALL NOTIFY | | | THE OCCUPANTS OF NEIGHBORING PROPERTIES ABOUT ALL | | | STAGES OF CONSTRUCTION THAT MAY AFFECT THE USE OF THEIR | | | PROPERTY. | | | | | | 9. INFORMATIONAL: BUILDING ADDRESS. EACH SEPARATE | | | BUILDING, AND UNIT WITH AN INDEPENDENT ENTRANCE FROM | | | THE STREET, SHALL HAVE A SEPARATE ADDRESS ASSIGNED | | | BASED ON THE LOCATION OF THE BUILDING ENTRANCE. FOR | | | STREET ADDRESSING, CONTACT CAROLINE PUELL, ADDRESSING | | | COORDINATOR, AT (561) 805 6659, OR BY EMAIL: | | | [email protected] | | | | | | | | | | | | ROBERT BROWN | | | BUILDING OFFICIAL | | | TEL: 561 805 6652 | | | EMAIL: [email protected] | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
10-12-2022 |
|
|
Cont ID |
|
| Sent By |
rbrown |
Date |
10-12-2022 |
Time |
20:48 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
10-12-2022 |
Time |
20:47 |
Sent To |
|
|
| Notes |
| 2022-10-12 20:53:50 | DEVELOPMENT SERVICES DEPARTMENT, BUILDING DIVISION, | | | COMMENTS: | | | | | | 1. THIS REVIEW IS A CURSORY REVIEW AS IT RELATES TO THE | | | SITE. IT IS NOT A REVIEW FOR FULL COMPLIANCE WITH | | | FLORIDA BUILDING CODE. THE FOLLOWING COMMENTS ARE TO BE | | | ADDRESSED FOR THE BUILDING PERMIT APPLICATION. | | | | | | 2. DEMOLITION OF THE EXISTING BUILDINGS. AN ASBESTOS | | | SURVEY SHALL BE PERFORMED AND AN ASBESTOS ABATEMENT | | | REPORT SUBMITTED TO THE HEALTH DEPARTMENT PALM BEACH | | | COUNTY OFFICE. CONTACT ALEX ORTEGA AT (561) 837-5963, | | | OR BY EMAIL: [email protected] | | | | | | 3. VAN ACCESSIBLE PARKING SPACES. PER SECTION 208.2.4 | | | OF FLORIDA ACCESSIBILITY CODE, ONE IN EVERY SIX | | | REQUIRED ACCESSIBLE SPACES (AT LEAST ONE) IN A PARKING | | | STRUCTURE, SHALL BE ???VAN ACCESSIBLE??? AND DESIGNED | | | IN ACCORDANCE WITH SECTION OF 502 OF FLORIDA | | | ACCESSIBILITY CODE (VERTICAL CLEARANCE NOT LESS THAN 98 | | | INCHES AT SPACE AND VEHICULAR ACCESS ROUTE) | | | | | | 4. ELECTRIC VEHICLE CHARGING STATION. IF ELECTRIC | | | VEHICLE (EV) CHARGING STATIONS ARE PROVIDED AT LEAST 1 | | | IN 25 MUST COMPLY WITH ACCESSIBLE PARKING SPACE | | | REQUIREMENTS. | | | | | | 5. BUILDING SIZE. WHEN SUBMITTED FOR BUILDING PERMIT, | | | THE PLANS SHALL SHOW THAT THE TYPE OF CONSTRUCTION FOR | | | THE BUILDINGS WILL BE IN ACCORDANCE WITH THE HEIGHT, | | | AREA AND OCCUPANCY LIMITATIONS IN CHAPTER 5 OF THE | | | FLORIDA BUILDING CODE. | | | | | | 6. BUILDING LOCATION RELATIVE TO THE PROPERTY LINE AND | | | OTHER STRUCTURES. WHEN SUBMITTED FOR BUILDING PERMIT, | | | COMPLIANCE WITH ALL BUILDING SEPARATION, PERCENTAGE OF | | | OPENINGS AND OPENING PROTECTIVE REQUIREMENTS OF | | | CHAPTERS 6 AND 7 OF THE FLORIDA BUILDING CODE SHALL BE | | | VERIFIED. | | | | | | 7. ENCLOSED PARKING GARAGES. IF THE PARKING GARAGE DOES | | | NOT HAVE WALL OPENINGS, OR SUFFICIENT WALL OPENINGS TO | | | MEET THE DEFINITION OF AN OPEN PARKING GARAGE, IT WILL | | | BE CONSIDERED AN ENCLOSED PARKING GARAGE AND MUST HAVE | | | EXHAUST SYSTEMS. THE EXHAUST SYSTEMS SHALL BE DESIGNED | | | TO MINIMIZE NOISE LEVELS USING INLINE FAN SILENCERS OR | | | OTHER APPROVED METHODS. | | | | | | 8. GREASE INTERCEPTOR. IF ANY OF THE RETAIL SPACES WILL | | | BE RESTAURANT USE, A GREASE INTERCEPTOR WILL BE | | | REQUIRED. FOR INFORMATION ON THE REQUIRED TYPE, SIZE | | | AND LOCATION, PLEASE CONTACT RYAN BROWN, CHIEF PLUMBING | | | INSPECTOR, DEVELOPMENT SERVICES DEPARTMENT, AT (561) | | | 805-6692, OR BY EMAIL: [email protected] | | | | | | 9. SEPARATE PERMITS REQUIRED. ALL APPLICABLE PERMITS | | | AND SUB-PERMITS MUST BE OBTAINED BEFORE COMMENCING THE | | | WORK. SEPARATE PERMITS, PLANS AND FEES, ARE REQUIRED | | | FOR SIGNS, SWIMMING POOLS AND SPAS, GAS SYSTEMS, | | | GENERATORS, FIRE ALARM SYSTEMS, FIRE SPRINKLER AND | | | OTHER FIRE SUPPRESSION SYSTEMS, GREASE INTERCEPTORS, | | | SITE LIGHTING, SITE LANDSCAPE, SITE IRRIGATION, ETC. | | | | | | 10. CONTRACTOR VEHICLE PARKING. PROPERTY OWNER AND | | | CONTRACTOR SHALL MAKE ARRANGEMENTS FOR PARKING OF | | | CONTRACTOR VEHICLES TO MINIMIZE THE IMPACT ON ALL | | | NEIGHBORING PROPERTIES. | | | | | | 11. PROTECTION OF NEIGHBORING PROPERTY. PROPERTY OWNER | | | AND CONTRACTOR SHALL PROTECT ALL NEIGHBORING PROPERTY, | | | INCLUDING VEHICLES, FROM DAMAGE OR DIRT CAUSED BY THE | | | CONSTRUCTION, AND SHALL NOTIFY THE OCCUPANTS OF | | | NEIGHBORING PROPERTIES ABOUT ALL STAGES OF CONSTRUCTION | | | THAT MAY AFFECT THE USE OF THEIR PROPERTY. | | | | | | 12. BUILDING ADDRESS. EACH SEPARATE BUILDING, AND UNIT | | | WITH AN INDEPENDENT ENTRANCE FROM THE STREET, SHALL | | | HAVE A SEPARATE ADDRESS ASSIGNED BASED ON THE LOCATION | | | OF THE BUILDING ENTRANCE. FOR STREET ADDRESSING, | | | CONTACT CAROLINE PUELL, ADDRESSING COORDINATOR, AT | | | (561) 805 6659, OR BY EMAIL: [email protected] | | | | | | 13. ART IN PUBLIC PLACES. THIS PROJECT WILL BE SUBJECT | | | TO ART LIFE ASSESSMENT UNDER THE CITY OF WEST PALM | | | BEACH ART IN PUBLIC PLACES (AIPP) PROGRAM. FOR ADVICE | | | ON THE PROVISION OF PUBLIC ARTWORK IN LIEU OF THE AIPP | | | ASSESSMENT, CONTACT SYBILLE WELTER, ART IN PUBLIC | | | PLACES COORDINATOR, AT (561) 822-1521, OR BY EMAIL: | | | [email protected] | | | | | | ROBERT BROWN | | | BUILDING OFFICIAL | | | TEL: 561 805 6652 | | | EMAIL: [email protected] | | | |
|
|
| Review Stop |
ENG - PPRC |
ENGINEERING - PPRC |
| Rev No |
2 |
Status |
P |
Date |
11-03-2022 |
|
|
Cont ID |
|
| Sent By |
rrossano |
Date |
11-03-2022 |
Time |
|
Rev Time |
0.00 |
| Received By |
rrossano |
Date |
11-03-2022 |
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
ENG - PPRC |
ENGINEERING - PPRC |
| Rev No |
1 |
Status |
F |
Date |
09-26-2022 |
|
|
Cont ID |
|
| Sent By |
RROSSANO |
Date |
09-26-2022 |
Time |
|
Rev Time |
|
| Received By |
rrossano |
Date |
09-26-2022 |
Time |
|
Sent To |
|
|
| Notes |
| 2022-09-26 13:13:53 | COMMENTS FROM RICK ROSSANO, SR. PROJECT COORDINATOR, | | | ENGINEERING SERVICES AT 561-494-1098 [email protected] | | | GENERAL: | | | O PLEASE RESPOND TO ALL COMMENTS IN WRITING, AND | | | INCLUDE PROJECT NAME, ADDRESS AND PERMIT NUMBER | | | (Z-XXXXXXXX). | | | O THE CITY OF WEST PALM BEACH HAS A NUMBER OF | | | REGULATIONS AND PERMIT REQUIREMENTS WHICH DIRECTLY | | | AFFECT THE DEVELOPMENT AND INSTALLATION OF WATER AND | | | WASTEWATER UTILITIES WITHIN THE CITY. PLEASE SEE | | | DEVELOPMENT PERMIT SUBMITTAL REQUIREMENTS AT THE LINK | | | BELOW: | | | A. HTTP://WPB.ORG/CMSPAGES/GETAMAZONFILE.ASPX?PATH=~\WP | | | B_WEBSITE\MEDIA\ENGINEERING\DEVELOPMENT-APPLICATION-FUL | | | L-PACKAGE_2016.PDF&HASH=7BD4DD7EB6115181D8C5977BCC02A97 | | | B1960045731D3658206F27451722716EF | | | B. THIS AND OTHER RELATED ENGINEERING DOCUMENTS CAN BE | | | FOUND HERE: | | | HTTP://WPB.ORG/DEPARTMENTS/ENGINEERING-PUBLIC-WORKS/FOR | | | MS,-PERMITS-APPLICATIONS | | | C. ALSO SEE: CODE OF ORDINANCES, CITY OF WEST PALM | | | BEACH, FLORIDA, CODIFIED THROUGH ORD. NO. 4183-08, | | | ADOPTED SEPT. 22, 2008. (SUPPLEMENT NO. 18) | | | CHAPTER 90 UTILITIES, ARTICLE I. IN GENERAL, | | | SEC. 90-7. POLICY REGARDING EXTENSION OF WATER OR SEWER | | | SERVICE FACILITIES OF THE CITY. | | | THE WATER AND WASTEWATER SERVICE AGREEMENTS AND THE | | | CONSTRUCTION PERMITS ADDRESS RESERVATION OF CAPACITY | | | BASED ON USAGE, METER SIZE AND FEES, DESIGN STANDARDS, | | | BACKFLOW PREVENTION, FIRE SERVICE AND IRRIGATION. | | | O AS OF DECEMBER 20, 2015, THE CITY OF WEST PALM BEACH | | | CROSS-CONNECTION CONTROL MANUAL HAS BEEN REVISED, | | | STATING "ALL BACKFLOW DEVICES MUST BE LEAD-FREE". FOR | | | MORE INFORMATION, REFER TO THE LINK BELOW: | | | A. HTTP://WPB.ORG/DEPARTMENTS/PUBLIC-UTILITIES/FORMS-PU | | | BLICATIONS/BACKFLOW-CROSS-CONNECTION- CONTROL-MANUAL | | | O PLEASE SUBMIT A FORMAL AS-BUILT REQUEST FOR ALL CITY | | | OF WEST PALM BEACH-OWNED UTILITIES WITHIN THE PUBLIC | | | RIGHT OF WAY FOR THE ENTIRE EXTENT OF THE LIMITS OF | | | YOUR PROJECT. IDENTIFY TYPE OF UTILITY, LOCATION, PIPE | | | MATERIAL, AGE AND SIZE. PLEASE CONTACT JANICE TARBILL | | | IN THE WPB ENGINEERING SERVICES DEPARTMENT AT | | | [email protected] OR 561-494-1079 FOR FURTHER | | | ASSISTANCE. NOTE THAT FIELD RECORDS ARE FOR INFORMATION | | | ONLY. FIELD VERIFY UTILITY LOCATIONS USING FIELD | | | SURVEY, POT-HOLING, SOFT DIGS ETC. | | | O PROVIDE EXISTING AND PROPOSED PERVIOUS AND IMPERVIOUS | | | DATA. | | | | | | BACKFLOW ASSEMBLY AND METERS: | | | O SHOW AND LABEL ANY EXISTING OR PROPOSED WATER | | | SERVICES AND WATER METERS, ALONG WITH WHAT IS HAPPENING | | | TO THEM. | | | O SHOW EXISTING AND PROPOSED DEDICATED UTILITY | | | EASEMENTS TO ALLOW ACCESS FOR CITY PERSONNEL TO | | | PROPOSED UTILITY WATER METERS. VERIFY THAT THERE ARE NO | | | STRUCTURES WITHIN EASEMENT. | | | O PROVIDE ENLARGED VIEW ON PLANS OF PROPOSED LOCATION | | | OF WATER METER AND BACKFLOW | | | PREVENTION. | | | O BACKFLOWS SHALL BE INSTALLED ON PRIVATE PROPERTY | | | OUTSIDE OF EASEMENTS AND RIGHTS OF WAY. DOMESTIC WATER | | | METERS SHALL BE INSTALLED IMMEDIATELY ADJACENT TO | | | PROPERTY LINE. 3 INCH AND LARGER WATER METERS SHALL BE | | | INSTALLED ABOVE-GROUND ONLY. | | | O CALLOUT DOMESTIC BACKFLOW PREVENTER AS RPPA (MAKE | | | NOTE USC APPROVED) AND FIRE BACKFLOW PREVENTER AS DCDA. | | | | | | WATER/WASTEWATER PLAN: | | | O PROVIDE VERTICAL DATUM AND DATUM CONVERSION | | | INFORMATION (NAVD 1988 AND NGVD 1929). | | | O SHOW PROJECT ADDRESS ON ALL PLAN SHEETS. | | | O PROVIDE LEGEND ON ALL PLAN SHEETS TO INCLUDE | | | STREETLIGHT, SIGN POSTS, TRANSFORMER BOXES ETC. | | | O PLANS SHALL SHOW EXISTING AND PROPOSED LOCATIONS AND | | | DIMENSIONS OF ALL WATER, STORMWATER, AND SANITARY AND | | | SEWER LINES AND CLEANOUTS, INCLUDING STUBS TO EACH | | | PROPERTY LINE FOR WATER AND SANITARY SEWERS, THE MAKE | | | AND MODEL OF ALL VALVES, POTABLE AND IRRIGATION METERS, | | | BACKFLOWS, FIRE HYDRANTS AND FDCS, AND OTHER DEVICES TO | | | BE INSTALLED ON THE SYSTEM, CATCH BASINS, CULVERTS, | | | DITCHES INCLUDING GRADES, PIPES SIZES, MATERIALS, | | | ELEVATIONS, ASSUMPTIONS, CALCULATIONS, INVERT | | | ELEVATIONS FOR ALL INLETS AND MANHOLES AND PROFILES OF | | | SANITARY SEWER LINES. | | | O GATE VALVE BOXES SHALL NOT BE INSTALLED IN CURB OR | | | SIDEWALK. ALL AVAILABLE ELEVATION SHALL BE SHOWN ON THE | | | PROFILE VIEW. | | | O DIRECTION OF FLOW SHALL BE SHOWN ON PLAN VIEW ON PLAN | | | VIEW FOR ALL SANITARY AND STORM SEWERS. | | | O SHOW SLOPE % ON ALL SANITARY LINES AND CALL OUT | | | MATERIAL. | | | O PLAN VIEW SHALL SHOW ALL EXISTING AND PROPOSED | | | UNDERGROUND UTILITY LAYOUT, INCLUDING FIBER OPTIC, | | | ELECTRIC, GAS, AND CABLEVISION & TELECOMMUNICATION | | | FACILITIES INCLUDING PIPE SIZE AND MATERIAL LOCATED IN | | | THE RIGHT-OF-WAY. | | | O PROVIDE PROFILE AND CLEARANCES BETWEEN WATER, SEWER | | | AND STORM LINES PER CITY OF WEST PALM BEACH STANDARD | | | DETAIL GN-2 SERIES, AT ALL UTILITY CROSSINGS. PLEASE | | | INCLUDE FIBER OPTIC, ELECTRIC, GAS, AND CABLEVISION & | | | TELECOMMUNICATION FACILITIES INCLUDING PIPE SIZE AND | | | MATERIAL LOCATED IN THE RIGHT-OF-WAY. | | | O SUBMIT COMPLETED LOS ANALYSIS SUMMARY TABLE DIRECTLY | | | TO ENGINEERING (SHEET 33 OF CITY OF WPB DEVELOPMENT | | | APPLICATION). PROVIDE CALCULATIONS ON PLANS OF EXISTING | | | AND PROPOSED DEMANDS FOR WATER & SEWER (AVERAGE, | | | MAXIMUM AND PEAK) AND FIRE FLOW DEMANDS. CALCULATIONS | | | SHALL BE PER FAC 64E-6 FOR SEWER AND PER FAC 64-E.008 | | | FOR WATER. | | | O PROVIDE FIRE FLOW TEST DATA. | | | O PROVIDE CCTV VIDEO OF EXISTING SANITARY SEWER AND | | | STORMWATER INFRASTRUCTURE ALONG ENTIRE PROJECT FRONTAGE | | | (CONDITION OF SITE PLAN APPROVAL). | | | O CUT AND CAP UTILITIES NOT IN USE AND REMOVE ANY | | | ABANDONED UTILITY LINES LARGER THAN 2 INCHES FROM CITY | | | ROW. | | | O WHEN PROPOSED, WATER MAINS IN CITY RIGHT OF WAY SHALL | | | BE MADE OF DUCTILE IRON PIPE (NOT PVC) AND SPECIFY | | | PROPOSED LENGTH IN FEET. | | | O CHECK TO SEE IF FDEP FORMS FOR PROPOSED SANITARY | | | SEWER ARE REQUIRED. | | | O PROVIDE CLEANOUTS FOR PROPOSED SANITARY LINE ONSITE | | | JUST INSIDE PROPERTY LINE, AT JOINTS AND EVERY 75 FEET. | | | O ADD NOTE TO PLANS SPECIFYING CITY???S DOWNSTREAM LIFT | | | STATION NUMBER. | | | O PROVIDE ONSITE CLEANOUTS NEAR PROPERTY LINE FOR | | | PROPOSED SANITARY LATERALS. | | | O LABEL WATER LINES AS PRIVATE WHERE APPLICABLE. | | | O PLEASE SHOW AND LABEL EXISTING AND PROPOSED GREASE | | | TRAPS (IF ANY). | | | O PER CITY STANDARDS MAINTAIN MINIMUM DISTANCE BETWEEN | | | OUTSIDE DIAMETER OF CITY PIPE AND ROOT BARRIER. | | | | | | FORMAL ENGINEERING REVIEW: | | | O FOR FORMAL ENGINEERING SUBMITTAL, SFWMD ERP AND NPDES | | | NOI REQUIREMENTS WILL BE ENFORCED. | | | - AN NOI IS REQUIRED FOR PROJECTS THAT: | | | - 1) DISTURB ONE OF MORE ACRES OF LAND OR DISTURB LESS | | | THAN ON ACRE OF LAND BUT ARE PART OF A COMMON PLAN OF | | | DEVELOPMENT OR SALE; | | | - 2) DISCHARGE STORMWATER TO SURFACE WATERS OF THE | | | STATE OR TO SURFACE WATERS OF THE STATE THROUGH A | | | MUNICIPAL SEPARATE STORM SEWER SYSTEM (MS4). | | | - THE SFWMD ERP CAN BE OBTAINED THROUGH A 10-2 SELF | | | CERTIFICATION THROUGH FDEP OR AN ERP APPLICATION | | | THROUGH SFWMD. EITHER WAY, THE DEVELOPER/ENGINEER SHALL | | | SUBMIT A COPY OF THE ERP PERMIT OR FDEP ACKNOWLEDGEMENT | | | OF THE 10-2 CERTIFICATION. | | | O FOR FORMAL ENGINEERING SUBMITTAL, PLEASE PROVIDE | | | EASEMENT FOR PLACEMENT OF PROPOSED WATER METERS. | | | O FOR FORMAL ENGINEERING SUBMITTAL, PROVIDE PROFILES OF | | | WATER AND SEWER AND SHOW ANY CROSSINGS/CONFLICTS. | | | O FOR FORMAL ENGINEERING SUBMITTAL, WHEN SUBMITTING | | | APPROVED MATERIALS LIST, PLEASE PROVIDE MATERIAL/CUT | | | SHEETS FOR ALL PROPOSED BACKFLOW DEVICES SHOWING | | | SPECIFIC MODEL NUMBER AND SPECIFYING USC APPROVED | | | LEAD-FREE DESIGN. | | | O FOR FORMAL ENGINEERING SUBMITTAL, IF SANITARY LINES | | | ARE PROPOSED IN ROW PLEASE SHOW ADJACENT SANITARY | | | LATERAL LOCATIONS AND SHOW ADDRESSES OF ADJACENT | | | PARCELS. | | | O FOR FORMAL ENGINEERING SUBMITTAL, IF WATER LINES ARE | | | BEING REPLACED IN ROW, SHOW ADJACENT PARCEL ADDRESSES. | | | O FOR FORMAL ENGINEERING SUBMITTAL, ADD NOTE TO PROVIDE | | | 50 FT. PAVEMENT RESTORATION TRANSITION ON EACH SIDE OF | | | PROPOSED TRENCH IN CITY MAINTAINED ROADWAY AREAS PER | | | CITY OF WPB STANDARD DETAIL GC-8. | | | O FOR FORMAL ENGINEERING SUBMITTAL, PLEASE PROVIDE | | | CALCULATIONS OF PERVIOUS AND IMPERVIOUS AREAS FOR | | | PROPOSED IMPROVED AREAS. | | | | | | QUESTIONS AND COORDINATION CONTACTS: | | | O MARK HURLEY, FIELD CUSTOMER SERVICE SUPERVISOR WITH | | | CITY OF WPB PUBLIC UTILITIES, REGARDING PLACEMENT OF | | | BACKFLOW DEVICES AND WATER METERS. CONTACT HIM AT | | | 561-822-2262 OR [email protected] | | | O MIKE TECHNOW, PROJECT ENGINEER, PUBLIC UTILITIES | | | DEPARTMENT AT 561-494-1047 OR [email protected] | | | O TRACY WARD, SR. STORMWATER ENGINEER, ENGINEERING | | | SERVICES DEPT. AT 561-494-1120 OR [email protected] | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
09-29-2022 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
09-29-2022 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
09-29-2022 |
Time |
13:30 |
Sent To |
|
|
| Notes |
| 2022-09-29 13:38:18 | THE FOLLOWING COMMENTS WERE SUBMITTED BY PETER LEDUC, | | | FIRE MARSHAL, BUREAU OF FIRE PREVENTION, WEST PALM | | | BEACH FIRE RESCUE. | | | | | | THIS REVIEW CAN ONLY BE CONSIDERED PRELIMINARY AS THE | | | DRAWINGS THAT WERE REVIEWED WERE NOT COMPLETE. | | | ADDITIONAL COMMENTS CAN BE EXPECTED WHEN FULL DRAWINGS | | | ARE SUBMITTED FOR PERMIT. | | | | | | THE FIRE PREVENTION BUREAU HAS NO OBJECTIONS TO THE | | | PROPOSED PROJECT; HOWEVER, THE FOLLOWING COMMENTS ARE | | | PROVIDED AND MAY NEED FURTHER CLARIFICATIONS WHERE | | | APPLICABLE. | | | | | | 1. CONSTRUCTION, DEMOLITION, AND RENOVATION TO COMPLY | | | WITH NFPA 241. EXTRA ATTENTION SHALL BE GIVEN TO THE | | | PERMITTING AND LOCATION OF CONSTRUCTION TRAILERS. A | | | PERMIT IS REQUIRED FOR ANY CONSTRUCTION TRAILER RELATED | | | TO THIS PROJECT. SEPARATION DISTANCES FROM MAIN | | | STRUCTURES AS WELL AS OTHER TRAILERS SHALL BE CLOSELY | | | MONITORED FOR THE REQUIREMENTS OF FIRE SPRINKLER | | | PROTECTION. | | | | | | 2. SITE ACCESS AND EXIT POINTS ARE TO BE CLEARLY | | | IDENTIFIED AND MAINTAINED FOR EMERGENCY VEHICLES DURING | | | ALL CONSTRUCTION ACTIVITIES. | | | | | | 3. THE BUILDING ADDRESS SHALL BE CLEARLY VISIBLE FROM | | | ALL ACCESS ROADWAYS, INCLUDING DURING CONSTRUCTION. | | | ADDRESS NUMBERS SHALL CONTRAST WITH THEIR BACKGROUND | | | AND SHALL NOT BE LESS THAN SIX (6) INCHES IN HEIGHT | | | WITH A ONE (1) INCH STROKE FOR ALL BUILDINGS. | | | | | | 4. DURING CONSTRUCTION, TRASH AND DEBRIS IS TO BE | | | REMOVED FROM THE SITE DAILY OR MORE OFTEN TO REDUCE THE | | | ACCUMULATION OF POTENTIAL LIFE AND FIRE SAFETY HAZARDS. | | | 5. THE CONSTRUCTION OF THE BUILDING SHALL COMPLY WITH | | | THE 7TH EDITION OF THE FLORIDA FIRE PREVENTION CODE, | | | INCLUDING NFPA 1 & 101, AND ALL ASSOCIATED FIRE CODES. | | | | | | 6. ALL PARKING STRUCTURES SHALL COMPLY WITH NFPA 88A, | | | PARKING STRUCTURES AND NFPA 101, THE LIFE SAFETY CODE, | | | INCLUDING MORE SPECIFICALLY, CHAPTER 42 STORAGE | | | OCCUPANCIES (PARKING STRUCTURES) | | | | | | 7. A NFPA 13 COMPLAINT FIRE SPRINKLER SYSTEM AND NFPA | | | 14 COMPLIANT WET STANDPIPE SYSTEM ARE REQUIRED FOR THIS | | | STRUCTURE. TEMPORARY STANDPIPES ARE REQUIRED WHEN THE | | | BUILDING REACHES THREE LEVELS OR THIRTY FEET WHILE | | | BEING CONSTRUCTED. SEPARATE SHOP DRAWINGS, ARE REQUIRED | | | TO BE SUBMITTED, REVIEWED AND APPROVED BY THE FIRE | | | PREVENTION BUREAU PRIOR TO ANY INSTALLATION. | | | IT IS RECOMMENDED FOR HIGH RISES HAVE TWO SEPARATE FDC | | | LOCATIONS REMOTELY LOCATED TO SERVE THE STANDPIPE | | | SYSTEM. | | | | | | 7A. PER NFPA 14 | | | 6.4.5.4* FIRE DEPARTMENT CONNECTIONS SHALL BE LOCATED | | | NOT MORE THAN 100 FT (30.5 M) FROM THE NEAREST FIRE | | | HYDRANT CONNECTED TO AN APPROVED WATER SUPPLY. | | | | | | THE PROPOSED FDC LOCATIONS ARE ACCETPABLE. | | | | | | 7B. PER NFPA 1 | | | | | | 18.3 WATER SUPPLIES. | | | 18.3.1* AN APPROVED WATER SUPPLY CAPABLE OF SUPPLYING | | | THE REQUIRED FIRE FLOW FOR FIRE PROTECTION SHALL BE | | | PROVIDED TO ALL PREMISES UPON WHICH FACILITIES, | | | BUILDINGS, OR PORTIONS OF BUILDINGS ARE HEREAFTER | | | CONSTRUCTED OR MOVED INTO THE JURISDICTION. THE | | | APPROVED WATER SUPPLY SHALL BE IN ACCORDANCE WITH | | | SECTION 18.4. | | | | | | PER FLORIDA ADMINISTRATIVE CODE SECTION 61G15-32.004, | | | FIRE PROTECTION ENGINEERING DOCUMENTS SHALL INCLUDE THE | | | POINT OF SERVICE FOR THE WATER SUPPLY, A LIST OF | | | APPLICABLE NFPA STANDARDS APPLICABLE TO THE PROJECT, | | | CLASSIFICATION OF HAZARD OCCUPANCY FOR EACH ROOM OR | | | AREA, SUPPRESSION SYSTEM TYPE, DESIGN DENSITIES, WATER | | | SUPPLY DATA (FIRE PUMP DATA, HYDRANT FLOW TEST DATA) | | | AND ANY PERFORMANCE BASED INFORMATION SUCH AS | | | PRE-ENGINEERED SYSTEMS. | | | FOR THE PROPOSED FIRE PUMP(S) , WHAT IS(ARE) THE | | | PRIMARY AND SECONDARY POWER SOURCES? | | | | | | 7C. THE LOCATION OF THE DDCV FIRE LINE LOCATION SHALL | | | MEET THE REQUIREMENTS OF NFPA 24 AND SHALL BE | | | COORDINATED WITH THE OFFICE OF FIRE MARSHAL, THE CITY'S | | | ENGINEERS OFFICE, THE LANDSCAPE PLANNER, AND THE CITY'S | | | PLANNING AND ZONING OFFICE. | | | | | | THE PROPOSED UNDERGROUND VAULT MAY NOT BE ACCEPTABLE BY | | | THE CITY'S UTILITY DEPARTMENT. PLEASE ENSURE THAT THEY | | | ARE AWARE AND COORDINATE ANY CORRECTIONS/CHANGES. | | | | | | 8. A NFPA 72 COMPLIANT MONITORED FIRE ALARM SYSTEM IS | | | REQUIRED FOR THIS STRUCTURE. SEPARATE SHOP DRAWINGS, | | | ARE REQUIRED TO BE SUBMITTED, REVIEWED AND APPROVED BY | | | THE FIRE PREVENTION BUREAU PRIOR TO ANY INSTALLATION. | | | | | | 9. ALL ELEVATORS SHALL BE EQUIPPED WITH A REGION 7 | | | KEYWAY SYSTEM FOR BUILDING 6 OR MORE STORIES. | | | | | | ALL NEW ELEVATORS SHALL CONFORM TO THE FIRE FIGHTER???S | | | EMERGENCY OPERATIONS REQUIREMENTS OF ASME A17.1/CSA | | | B44, SAFETY CODE FOR ELEVATORS. | | | | | | ANY BUILDING THAT IS MORE THAN THREE STORIES HIGH OR IN | | | WHICH THE VERTICAL DISTANCE BETWEEN THE BOTTOM TERMINAL | | | LANDING AND THE TOP TERMINAL LANDING EXCEEDS 25 FEET | | | MUST BE CONSTRUCTED TO CONTAIN AT LEAST ONE PASSENGER | | | ELEVATOR THAT IS OPERATIONAL AND WILL ACCOMMODATE AN | | | AMBULANCE STRETCHER 76 INCHES LONG AND 24 INCHES WIDE | | | IN THE HORIZONTAL POSITION. | | | | | | 10. COMPLETE LIFE SAFETY PLANS FOR EACH OCCUPANCY SHALL | | | BE PROVIDED THAT ILLUSTRATE OCCUPANT LOADS, TRAVEL | | | DISTANCES, COMMON PATHS OF TRAVEL, DEAD-END CORRIDORS, | | | EXIT SIGNS, EMERGENCY LIGHTING, EXITS LEADING TO A | | | PUBLIC WAY, FIRE EXTINGUISHER LOCATIONS, AND ALL FIRE | | | SAFETY FEATURES AND EQUIPMENT. | | | | | | 11. ALL EXISTING AND NEW FIRE HYDRANTS PLANNED FOR THIS | | | DEVELOPMENT SHALL BE CLEARLY INDICATED AND IDENTIFIED | | | ON THE PLAN AND CLOSELY COORDINATED WITH THE BUREAU OF | | | FIRE PREVENTION. | | | ALL NEW FIRE HYDRANTS AND FDC???S PLANNED FOR THIS | | | DEVELOPMENT SHALL BE CLOSELY COORDINATED WITH THE | | | BUREAU OF FIRE PREVENTION. PROPOSED FIRE HYDRANTS AND | | | FDC???S SHOULD BE LOCATED ON THE SAME SIDE OF THE | | | STREET OR ACCESS ROADWAY TO ALLOW FREE ACCESS FOR OTHER | | | ARRIVING EMERGENCY VEHICLES. | | | | | | 12. COMMAND ROOM | | | | | | THERE WAS NO CLEAR INDICATION OF THE LOCATION OF THE | | | FIRE COMMAND ROOM/CENTER. | | | | | | THE FCC SHOULD BE LOCATED IN AN AREA ACCESSIBLE FROM AN | | | EXTERIOR WALL WITH ADDITIONAL ACCESS TO THE INTERIOR, | | | IF POSSIBLE. | | | | | | THE LOCATION SHALL BE LOCATED IN COORDINATION WITH THE | | | OFFICE OF THE FIRE MARSHAL. | | | | | | THE FIRE COMMAND CENTER SHALL COMPLY WITH NFPA 1, | | | CHAPTER 11, BUILDING SERVICES; 11.9 AND SHALL CONTAIN | | | THE FOLLOWING FEATURES: | | | | | | 11.9.1 THE LOCATION, DESIGN, CONTENT, AND FIRE | | | DEPARTMENT ACCESS OF THE EMERGENCY COMMAND CENTER SHALL | | | BE APPROVED BY THE FIRE DEPARTMENT. | | | | | | 11.9.2 THE EMERGENCY COMMAND CENTER SHALL BE SEPARATED | | | FROM THE REMAINDER OF THE BUILDING BY A FIRE BARRIER | | | HAVING A FIRE RESISTANCE RATING OF NOT LESS THAN 1 | | | HOUR. | | | | | | 11.9.3 THE EMERGENCY COMMAND CENTER ROOM SHALL BE A | | | MINIMUM OF 200 FT2 (19 M2) WITH A MINIMUM DIMENSION OF | | | 10 FT (3050 MM). | | | | | | 11.9.4 THE FOLLOWING SHALL BE PROVIDED IN THE EMERGENCY | | | COMMAND CENTER. | | | (1) THE FIRE DEPARTMENT COMMUNICATIONS SYSTEM. | | | (2) A TELEPHONE FOR FIRE DEPARTMENT USE WITH CONTROLLED | | | ACCESS TO THE PUBLIC TELEPHONE SYSTEM | | | (3) SCHEMATIC BUILDING PLANS INDICATING THE TYPICAL | | | FLOOR PLAN AND DETAILING THE BUILDING CORE, MEANS OF | | | EGRESS, FIRE PROTECTION SYSTEMS, FIRE-FIGHTING | | | EQUIPMENT AND FIRE DEPARTMENT ACCESS | | | (4) WORK TABLE. | | | (5) IF APPLICABLE, A HAZARDOUS MATERIAL MANAGEMENT PLAN | | | FOR THE BUILDING. | | | 11.9.5 WHERE OTHERWISE REQUIRED, THE FOLLOWING DEVICES | | | OR FUNCTIONS SHALL BE PROVIDED WITHIN THE EMERGENCY | | | COMMAND CENTER. | | | (1) THE EMERGENCY VOICE/ALARM COMMUNICATION SYSTEM | | | CONTROL UNIT. | | | (2) FIRE DETECTION AND ALARM SYSTEM ANNUNCIATOR UNIT. | | | (3) ANNUNCIATOR UNIT VISUALLY INDICATING THE LOCATION | | | OF THE ELEVATORS AND WHETHER THEY ARE OPERATIONAL | | | (4) STATUS INDICATORS AND CONTROLS FOR AIR-HANDLING | | | SYSTEMS. | | | (5) CONTROLS FOR UNLOCKING STAIRWAY DOORS | | | SIMULTANEOUSLY | | | (6) SPRINKLER VALVE AND WATER FLOW DETECTOR DISPLAY | | | PANELS | | | (7) EMERGENCY AND STANDBY POWER STATUS INDICATORS | | | (8) FIRE PUMP STATUS INDICATORS | | | (9) GENERATOR SUPERVISION DEVICES AND MANUAL START AND | | | TRANSFER FEATURES. | | | (10) PUBLIC ADDRESS SYSTEM, WHERE SPECIFICALLY REQUIRED | | | BY OTHER SECTIONS OF THIS CODE | | | (11) CONTROLS REQUIRED FOR SMOKE CONTROL | | | | | | PER NFPA 101 | | | | | | 11.8.6* EMERGENCY COMMAND CENTER. | | | | | | 11.8.6.1 AN EMERGENCY COMMAND CENTER SHALL BE PROVIDED | | | IN A | | | LOCATION APPROVED BY THE FIRE DEPARTMENT. | | | | | | 11.8.6.2 THE EMERGENCY COMMAND CENTER SHALL CONTAIN THE | | | FOLLOWING: | | | (1) VOICE FIRE ALARM SYSTEM PANELS AND CONTROLS | | | (2) FIRE DEPARTMENT TWO-WAY TELEPHONE COMMUNICATION | | | SERVICE | | | PANELS AND CONTROLS WHERE REQUIRED BY ANOTHER SECTION | | | OF THIS | | | CODE | | | (3) FIRE DETECTION AND FIRE ALARM SYSTEM ANNUNCIATION | | | PANELS | | | (4) ELEVATOR FLOOR LOCATION AND OPERATION ANNUNCIATORS | | | (5) ELEVATOR FIRE RECALL SWITCH IN ACCORDANCE WITH ASME | | | A17.1/CSA B44, SAFETY CODE FOR ELEVATORS AND ESCALATORS | | | (6) ELEVATOR EMERGENCY POWER SELECTOR SWITCH(ES) WHERE | | | PROVIDED | | | IN ACCORDANCE WITH ASME A17.1/CSA B44 | | | (7) SPRINKLER VALVE AND WATERFLOW ANNUNCIATORS | | | (8) EMERGENCY GENERATOR STATUS INDICATORS | | | (9) CONTROLS FOR ANY AUTOMATIC STAIRWAY DOOR UNLOCKING | | | SYSTEM | | | (10) FIRE PUMP STATUS INDICATORS | | | (11) TELEPHONE FOR FIRE DEPARTMENT USE WITH CONTROLLED | | | ACCESS TO THE | | | PUBLIC TELEPHONE SYSTEM | | | (12) STAIRWAY VIDEO MONITORING EQUIPMENT AS REQUIRED BY | | | 11.8.8 | | | | | | | | | 13. TWO-WAY RADIO COMMUNICATIONS ENHANCEMENT SYSTEMS. | | | | | | NFPA 1, CHAPTER 11, BUILDING SERVICES; 11.10 TWO-WAY | | | RADIO ENHANCEMENT SERVICES. | | | 11.10.1 IN ALL NEW AND EXISTING BUILDINGS, MINIMUM | | | RADIO SIGNAL STRENGTH FOR FIRE DEPARTMENT | | | COMMUNICATIONS SHALL BE MAINTAINED AT A LEVEL | | | DETERMINED BY THE AHJ. | | | NFPA 72, 24.9 TWO-WAY RADIO COMMUNICATIONS ENHANCEMENT | | | SYSTEMS. | | | | | | 24.9.1 GENERAL. | | | 24.9.1.1 NON-INTERFERENCE. NO AMPLIFICATION SYSTEM | | | CAPABLE | | | OF OPERATING ON FREQUENCIES OR CAUSING INTERFERENCE ON | | | FREQUENCIES | | | ASSIGNED TO THE JURISDICTION BY THE FCC SHALL BE | | | INSTALLED | | | WITHOUT PRIOR COORDINATION AND APPROVAL OF THE | | | AUTHORITY | | | HAVING JURISDICTION. THE BUILDING MANAGER/OWNER SHALL | | | SUSPEND AND CORRECT OTHER EQUIPMENT INSTALLATIONS THAT | | | DEGRADE | | | THE PERFORMANCE OF THE PUBLIC SAFETY RADIO SYSTEM OR | | | PUBLIC SAFETY RADIO ENHANCEMENT SYSTEM. | | | 24.9.1.2 APPROVAL AND PERMIT. PLANS SHALL BE SUBMITTED | | | FOR | | | APPROVAL PRIOR TO INSTALLATION. AT THE CONCLUSION OF | | | SUCCESSFUL | | | ACCEPTANCE TESTING, A RENEWABLE PERMIT SHALL BE ISSUED | | | FOR THE | | | PUBLIC SAFETY RADIO ENHANCEMENT SYSTEM WHERE REQUIRED | | | BY | | | THE AUTHORITY HAVING JURISDICTION. | | | | | | THE SYSTEM SHALL MAINTAIN A MINIMUM RADIO SIGNAL | | | STRENGTH OF THE RADIO SYSTEM USED BY WEST PALM BEACH | | | FIRE DEPARTMENT. TESTING SHALL BE BY AN ACCEPTABLE | | | NATIONAL STANDARD DOCUMENTING PERCENTAGES NOTED ABOVE | | | AND BY ACTUAL RADIO TESTING BY FIRE PERSONNEL. IF THE | | | MINIMUM CANNOT BE MAINTAINED, A BI-DIRECTIONAL | | | AMPLIFIED SYSTEM SHALL BE INSTALLED WITH A MINIMUM | | | 2-HOUR RUN TIME BATTERY BACK-UP. | | | PLEASE CONTACT MARK FILLA, PALM BEACH COUNTY PUBLIC | | | SAFETY RADIO SYSTEMS MANAGER, [email protected], | | | 561-233-0837; AS OUR RADIOS OPERATE ON THEIR SYSTEM FOR | | | DETAILED RADIO FREQUENCY AND INSTALLATION INSTRUCTIONS. | | | | | | 14. KNOX-BOX KEY SYSTEM SHALL BE REQUIRED FOR THIS | | | BUILDING. | | | ANY GATES SHALL BE PROVIDED WITH KNOX KEY ACCESS LOCKS, | | | PADLOCKS AND/OR SWITCHES FOR 24 HOUR EMERGENCY ACCESS. | | | | | | 15. THE SMOKE CONTROL SYSTEM SHALL COMPLY WITH NFPA | | | 101, CHAPTER 9, BUILDING SERVICE AND FIRE PROTECTION | | | EQUIPMENT, INCLUDING: | | | THE SMOKE CONTROL SYSTEMS SHALL BE INSTALLED, | | | INSPECTED, TESTED, AND MAINTAINED IN ACCORDANCE WITH | | | NFPA 92, STANDARD FOR SMOKE CONTROL SYSTEMS; NFPA 204, | | | STANDARD FOR SMOKE AND HEAT VENTING; OR NATIONALLY | | | RECOGNIZED STANDARDS, ENGINEERING GUIDES, OR | | | RECOMMENDED PRACTICES, AS APPROVED BY THE AUTHORITY | | | HAVING JURISDICTION. | | | | | | THE ENGINEER OF RECORD SHALL CLEARLY IDENTIFY THE | | | INTENT OF THE SYSTEM, THE DESIGN METHOD USED, THE | | | APPROPRIATENESS OF THE METHOD USED, AND THE REQUIRED | | | MEANS OF INSPECTING, TESTING, AND MAINTAINING THE | | | SYSTEM. | | | ACCEPTANCE TESTING SHALL BE PERFORMED BY A SPECIAL | | | INSPECTOR IN ACCORDANCE WITH SECTION 9.9. | | | | | | 16. AREAS OF REFUGE SHALL COMPLY WHERE APPLICABLE PER | | | THE BUILDING CODE AND NFPA 101, CH 7, MEANS OF EGRESS. | | | | | | 17. THE BUREAU'S APPROVAL OF THIS SUBMITTED PROJECT | | | DOES NOT CONSTITUTE IT'S FINAL REVIEW OR APPROVAL. | | | | | | 18. THE BUREAU SHALL REVIEW ALL SUBMITTED BUILDING | | | PLANS AT THE APPROPRIATE TIME AND IN ACCORDANCE WITH | | | THE REQUIREMENTS OF ALL APPLICABLE CODES AND STANDARDS. | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | | | | |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
3 |
Status |
P |
Date |
03-27-2023 |
|
|
Cont ID |
|
| Sent By |
rcaranci |
Date |
03-27-2023 |
Time |
11:40 |
Rev Time |
0.00 |
| Received By |
rcaranci |
Date |
03-27-2023 |
Time |
11:40 |
Sent To |
|
|
| Notes |
| 2023-03-27 11:41:16 | FROM: RAY CARANCI, SENIOR LANDSCAPE PLANNER | | | 561-822-1462 | | | PROJECT: 515 FERN ST Z22090013 | | | MARCH 27, 2023 | | | I HAVE REVIEWED THE ABOVE REFERENCED PETITION, AND | | | PROVIDE THE FOLLOWING COMMENTS: | | | | | | 1. SATISFIED. SECTION 94-448 (D)(3) REQUIRES NATIVE | | | TREES AND PALMS IN GOOD CONDITION TO BE PRESERVED ON | | | SITE OR RELOCATED. ANSI A 300 (PART 5) STANDARDS | | | SPECIFY EXAMPLES OF SUITABILITY RATINGS OF GOOD, | | | MODERATE, OR POOR FOR RELOCATION. PROVIDE THE ARBORISTS | | | REPORT RATING THE CONDITION AND RELOCATION POTENTIAL | | | FOR THE NATIVE TREES AND PALMS. | | | 11/29/22: SABAL PALMS QUALIFYING AS GOOD CONDITION ARE | | | TO BE SHOWN AS RELOCATE. #6, 11, 12, 22, AND 23. | | | CORRECT #65 AND 66 TO JACARANDA. | | | PER A SITE VISIT ON 11/29, IT APPEARS TREES HAVE BEEN | | | REMOVED FROM THE SITE WITHOUT A PERMIT BEING ISSUED. | | | | | | 2. SATISFIED. FOR THE REQUIRED PUBLIC OPEN SPACE, | | | PTYCHOSPERMA ELEGANS CANNOT BE COUNTED AS A LARGE PALM | | | TOWARD TREE CANOPY REQUIREMENT. | | | | | | 3. PROVIDE CALCULATIONS FOR REQUIRED STREET TREES AT | | | MAXIMUM SPACING EVERY 30 FEET OR PORTION THEREOF FOR | | | EACH STREETSCAPE LENGTH, AND SHOW THE NUMBER PROVIDED | | | PER SECTION 94-113. MAKE THE FOLLOWING CORRECTIONS: | | | ??? SATISFIED. THE NEW ROAD REQUIRES STREET TREE | | | CALCULATIONS FOR BOTH SIDES. | | | ??? SATISFIED. PALMS CAN BE ADDED TO THE STREETSCAPE | | | BUT ARE NOT COUNTED TOWARD THE SHADE TREE REQUIREMENT. | | | MAXIMUM SPACING IS 30 FEET. FERN ST DOES NOT MEET THE | | | SPACING REQUIREMENTS AND THE WEST SIDE OF THE NEW ROAD | | | MUST PROVIDE 10 TREES. | | | 11/29/22: 30 FOOT MAXIMUM SPACING OF SHADE TREES IS | | | POSSIBLE ON FERN STREET. | | | ??? SATISFIED. STREET TREES MUST BE IN THE REQUIRED 4 | | | FOOT WIDTH PLANTING STRIP ADJACENT TO THE CURB ON FERN | | | ST. | | | 11/29/22: PLANTING STRIP MUST BE PROVIDED AROUND THE | | | STREET TREES. | | | | | | | | | 4. SATISFIED. STREET TREES MUST MEET THE MINIMUM HEIGHT | | | OF 20 FEET. PROVIDE SPECIES LIVE OAKS OR CATHEDRAL | | | CULTIVAR INSTEAD OF HIGH RISE CULTIVAR. | | | | | | 5. SATISFIED. PROVIDE LOCATIONS AND DETAIL FOR THE | | | REQUIRED STRUCTURAL SOIL UNDER HARDSCAPE PER SECTION | | | 94-113 AND PROVIDE THE TYPICAL DETAIL FOR INSTALLATION. | | | THE DETAIL PROVIDED ON SHEET LP-6 DOES NOT MATCH CITY | | | DETAIL. THE AREA MUST BE 9 X14 FT PARALLEL TO THE CURB | | | FOR EACH TREE CONSISTING OF PLANTING AREA AND/OR | | | STRUCTURAL SOIL. ROOT BARRIERS WILL CUT OFF THE | | | STRUCTURAL SOIL, SO UTILITIES MUST BE COORDINATED I.E. | | | GAS LINE ALONG FERN. | | | | | | 6. MAKE THE FOLLOWING CORRECTIONS ON THE PLANT LIST: | | | ??? SATISFIED. JAPANESE BLUEBERRY TOPIARY AND GREEN | | | ISLAND FICUS TOPIARY MUST BE MOVED FROM THE TREE LIST | | | TO THE SHRUB LIST. | | | ??? SATISFIED. COCONUT IS NOT A FLORIDA NATIVE PLANT. | | | ??? SATISFIED. CLUSIA GUTTIFERA CAN BE COUNTED AS A | | | FLORIDA NATIVE PLANT. | | | | | | | | | | | | 7. SATISFIED. SHOW ALL EXISTING AND PROPOSED WATER AND | | | SEWER AND DRAINAGE LINES CLEARLY ON THE LANDSCAPE PLAN. | | | SHOW LOCATIONS OF BACKFLOWS AND ADJUST LOCATIONS OF | | | UTILITY LINES TO RESOLVE CONFLICTS WITH EXISTING AND | | | PROPOSED TREES AND LANDSCAPING. DRAINAGE LINES APPEAR | | | TO BE IN CONFLICT WITH TREES IN THE PUBLIC OPEN SPACE | | | PLAZA. | | | | | | | | | 8. SATISFIED. PROVIDE SCREENING HEDGES FOR ALL GROUND | | | MOUNTED VALVES AND EQUIPMENT AND ADD A NOTE THAT ALL | | | EQUIPMENT WILL BE SCREENED. | | | ADDITIONAL COMMENTS 11/29/22: | | | 9. SATISFIED. CLARIFY THE LANDSCAPE BUFFER AREA ALONG | | | THE WEST PROPERTY LINE AND PROVIDE THE REQUIRED | | | LANDSCAPING. PALMS MAY BE SUBSTITUTED FOR REQUIRED | | | TREES. LANDSCAPE PLAN DOES NOT MATCH THE SITE PLAN FOR | | | THE ACCESS LAYOUT. | | | | | | 10. SATISFIED. THE PLAN APPEARS TO SHOW THE 5 FOOT | | | LANDSCAPE BUFFER ON THE 360 ROSEMARY PROPERTY BEING | | | REMOVED AND REPLACED WITH A SIDEWALK. THIS WOULD | | | REQUIRE AMENDING THE APPROVED LANDSCAPING FOR 360 | | | ROSEMARY. | | | | | | | | | CONDITIONS OF APPROVAL | | | 1. PRIOR TO THE REMOVAL OR RELOCATION OF ANY TREES ON | | | THE PROPERTY, A TREE ALTERATION PERMIT SHALL BE | | | SUBMITTED, REVIEWED AND APPROVED BY THE DEVELOPMENT | | | SERVICES DEPARTMENT, PLANNING DIVISION. | | | | | | 2. THE APPLICANT, SUCCESSORS AND ASSIGNS SHALL BE | | | RESPONSIBLE FOR THE PERMITTING AND INSTALLATION OF THE | | | RIGHT OF WAY LANDSCAPING AND IRRIGATION APPROVED WITH | | | THIS PETITION. | | | | | | | | | 3. THE APPLICANT, SUCCESSORS AND ASSIGNS SHALL BE | | | RESPONSIBLE FOR THE MAINTENANCE OF THE STREETSCAPE | | | LANDSCAPING AND IRRIGATION. THIS WILL BE THROUGH A | | | SEPARATE MAINTENANCE AGREEMENT WITH THE CITY. | | | |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
2 |
Status |
F |
Date |
11-29-2022 |
|
|
Cont ID |
|
| Sent By |
rcaranci |
Date |
11-29-2022 |
Time |
16:36 |
Rev Time |
0.00 |
| Received By |
rcaranci |
Date |
11-29-2022 |
Time |
16:36 |
Sent To |
|
|
| Notes |
| 2022-11-29 16:37:26 | FROM: RAY CARANCI, SENIOR LANDSCAPE PLANNER | | | 561-822-1462 | | | PROJECT: 515 FERN ST Z22090013 | | | NOVEMBER 29, 2022 | | | I HAVE REVIEWED THE ABOVE REFERENCED PETITION, AND | | | PROVIDE THE FOLLOWING COMMENTS: | | | | | | 1. PARTIALLY SATISFIED. SECTION 94-448 (D)(3) REQUIRES | | | NATIVE TREES AND PALMS IN GOOD CONDITION TO BE | | | PRESERVED ON SITE OR RELOCATED. ANSI A 300 (PART 5) | | | STANDARDS SPECIFY EXAMPLES OF SUITABILITY RATINGS OF | | | GOOD, MODERATE, OR POOR FOR RELOCATION. PROVIDE THE | | | ARBORISTS REPORT RATING THE CONDITION AND RELOCATION | | | POTENTIAL FOR THE NATIVE TREES AND PALMS. | | | 11/29/22: SABAL PALMS QUALIFYING AS GOOD CONDITION ARE | | | TO BE SHOWN AS RELOCATE. #6, 11, 12, 22, AND 23. | | | CORRECT #65 AND 66 TO JACARANDA. | | | PER A SITE VISIT ON 11/29, IT APPEARS TREES HAVE BEEN | | | REMOVED FROM THE SITE WITHOUT A PERMIT BEING ISSUED. | | | | | | 2. SATISFIED. FOR THE REQUIRED PUBLIC OPEN SPACE, | | | PTYCHOSPERMA ELEGANS CANNOT BE COUNTED AS A LARGE PALM | | | TOWARD TREE CANOPY REQUIREMENT. | | | | | | 3. PROVIDE CALCULATIONS FOR REQUIRED STREET TREES AT | | | MAXIMUM SPACING EVERY 30 FEET OR PORTION THEREOF FOR | | | EACH STREETSCAPE LENGTH, AND SHOW THE NUMBER PROVIDED | | | PER SECTION 94-113. MAKE THE FOLLOWING CORRECTIONS: | | | ??? SATISFIED. THE NEW ROAD REQUIRES STREET TREE | | | CALCULATIONS FOR BOTH SIDES. | | | ??? PARTIALLY SATISFIED. PALMS CAN BE ADDED TO THE | | | STREETSCAPE BUT ARE NOT COUNTED TOWARD THE SHADE TREE | | | REQUIREMENT. MAXIMUM SPACING IS 30 FEET. FERN ST DOES | | | NOT MEET THE SPACING REQUIREMENTS AND THE WEST SIDE OF | | | THE NEW ROAD MUST PROVIDE 10 TREES. | | | 11/29/22: 30 FOOT MAXIMUM SPACING OF SHADE TREES IS | | | POSSIBLE ON FERN STREET. | | | ??? PARTIALLY SATISFIED. STREET TREES MUST BE IN THE | | | REQUIRED 4 FOOT WIDTH PLANTING STRIP ADJACENT TO THE | | | CURB ON FERN ST. | | | 11/29/22: PLANTING STRIP MUST BE PROVIDED AROUND THE | | | STREET TREES. | | | | | | | | | 4. SATISFIED. STREET TREES MUST MEET THE MINIMUM HEIGHT | | | OF 20 FEET. PROVIDE SPECIES LIVE OAKS OR CATHEDRAL | | | CULTIVAR INSTEAD OF HIGH RISE CULTIVAR. | | | | | | 5. SATISFIED. PROVIDE LOCATIONS AND DETAIL FOR THE | | | REQUIRED STRUCTURAL SOIL UNDER HARDSCAPE PER SECTION | | | 94-113 AND PROVIDE THE TYPICAL DETAIL FOR INSTALLATION. | | | THE DETAIL PROVIDED ON SHEET LP-6 DOES NOT MATCH CITY | | | DETAIL. THE AREA MUST BE 9 X14 FT PARALLEL TO THE CURB | | | FOR EACH TREE CONSISTING OF PLANTING AREA AND/OR | | | STRUCTURAL SOIL. ROOT BARRIERS WILL CUT OFF THE | | | STRUCTURAL SOIL, SO UTILITIES MUST BE COORDINATED I.E. | | | GAS LINE ALONG FERN. | | | | | | 6. MAKE THE FOLLOWING CORRECTIONS ON THE PLANT LIST: | | | ??? SATISFIED. JAPANESE BLUEBERRY TOPIARY AND GREEN | | | ISLAND FICUS TOPIARY MUST BE MOVED FROM THE TREE LIST | | | TO THE SHRUB LIST. | | | ??? SATISFIED. COCONUT IS NOT A FLORIDA NATIVE PLANT. | | | ??? SATISFIED. CLUSIA GUTTIFERA CAN BE COUNTED AS A | | | FLORIDA NATIVE PLANT. | | | | | | | | | | | | 7. SATISFIED. SHOW ALL EXISTING AND PROPOSED WATER AND | | | SEWER AND DRAINAGE LINES CLEARLY ON THE LANDSCAPE PLAN. | | | SHOW LOCATIONS OF BACKFLOWS AND ADJUST LOCATIONS OF | | | UTILITY LINES TO RESOLVE CONFLICTS WITH EXISTING AND | | | PROPOSED TREES AND LANDSCAPING. DRAINAGE LINES APPEAR | | | TO BE IN CONFLICT WITH TREES IN THE PUBLIC OPEN SPACE | | | PLAZA. | | | | | | | | | 8. SATISFIED. PROVIDE SCREENING HEDGES FOR ALL GROUND | | | MOUNTED VALVES AND EQUIPMENT AND ADD A NOTE THAT ALL | | | EQUIPMENT WILL BE SCREENED. | | | ADDITIONAL COMMENTS 11/29/22: | | | 9. CLARIFY THE LANDSCAPE BUFFER AREA ALONG THE WEST | | | PROPERTY LINE AND PROVIDE THE REQUIRED LANDSCAPING. | | | PALMS MAY BE SUBSTITUTED FOR REQUIRED TREES. LANDSCAPE | | | PLAN DOES NOT MATCH THE SITE PLAN FOR THE ACCESS | | | LAYOUT. | | | | | | 10. THE PLAN APPEARS TO SHOW THE 5 FOOT LANDSCAPE | | | BUFFER ON THE 360 ROSEMARY PROPERTY BEING REMOVED AND | | | REPLACED WITH A SIDEWALK. THIS WOULD REQUIRE AMENDING | | | THE APPROVED LANDSCAPING FOR 360 ROSEMARY. | | | | | | | | | CONDITIONS OF APPROVAL | | | 1. PRIOR TO THE REMOVAL OR RELOCATION OF ANY TREES ON | | | THE PROPERTY, A TREE ALTERATION PERMIT SHALL BE | | | SUBMITTED, REVIEWED AND APPROVED BY THE DEVELOPMENT | | | SERVICES DEPARTMENT, PLANNING DIVISION. | | | | | | 2. THE APPLICANT, SUCCESSORS AND ASSIGNS SHALL BE | | | RESPONSIBLE FOR THE PERMITTING AND INSTALLATION OF THE | | | RIGHT OF WAY LANDSCAPING AND IRRIGATION APPROVED WITH | | | THIS PETITION. | | | | | | | | | 3. THE APPLICANT, SUCCESSORS AND ASSIGNS SHALL BE | | | RESPONSIBLE FOR THE MAINTENANCE OF THE STREETSCAPE | | | LANDSCAPING AND IRRIGATION. THIS WILL BE THROUGH A | | | SEPARATE MAINTENANCE AGREEMENT WITH THE CITY. | | | |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
1 |
Status |
F |
Date |
10-04-2022 |
|
|
Cont ID |
|
| Sent By |
rcaranci |
Date |
10-04-2022 |
Time |
12:23 |
Rev Time |
0.00 |
| Received By |
rcaranci |
Date |
10-04-2022 |
Time |
12:22 |
Sent To |
|
|
| Notes |
| 2022-10-04 12:23:46 | FROM: RAY CARANCI, SENIOR LANDSCAPE PLANNER | | | 561-822-1462 | | | PROJECT: 515 FERN ST Z22090013 | | | OCTOBER 3, 2022 | | | I HAVE REVIEWED THE ABOVE REFERENCED PETITION, AND | | | PROVIDE THE FOLLOWING COMMENTS: | | | | | | 1. SECTION 94-448 (D)(3) REQUIRES NATIVE TREES AND | | | PALMS IN GOOD CONDITION TO BE PRESERVED ON SITE OR | | | RELOCATED. ANSI A 300 (PART 5) STANDARDS SPECIFY | | | EXAMPLES OF SUITABILITY RATINGS OF GOOD, MODERATE, OR | | | POOR FOR RELOCATION. PROVIDE THE ARBORISTS REPORT | | | RATING THE CONDITION AND RELOCATION POTENTIAL FOR THE | | | NATIVE TREES AND PALMS. | | | 2. FOR THE REQUIRED PUBLIC OPEN SPACE, PTYCHOSPERMA | | | ELEGANS CANNOT BE COUNTED AS A LARGE PALM TOWARD TREE | | | CANOPY REQUIREMENT. | | | | | | 3. PROVIDE CALCULATIONS FOR REQUIRED STREET TREES AT | | | MAXIMUM SPACING EVERY 30 FEET OR PORTION THEREOF FOR | | | EACH STREETSCAPE LENGTH, AND SHOW THE NUMBER PROVIDED | | | PER SECTION 94-113. MAKE THE FOLLOWING CORRECTIONS: | | | ??? THE NEW ROAD REQUIRES STREET TREE CALCULATIONS FOR | | | BOTH SIDES. | | | ??? PALMS CAN BE ADDED TO THE STREETSCAPE BUT ARE NOT | | | COUNTED TOWARD THE SHADE TREE REQUIREMENT. MAXIMUM | | | SPACING IS 30 FEET. FERN ST DOES NOT MEET THE SPACING | | | REQUIREMENTS AND THE WEST SIDE OF THE NEW ROAD MUST | | | PROVIDE 10 TREES. | | | ??? STREET TREES MUST BE IN THE REQUIRED 4 FOOT WIDTH | | | PLANTING STRIP ADJACENT TO THE CURB ON FERN ST. | | | | | | 4. STREET TREES MUST MEET THE MINIMUM HEIGHT OF 20 | | | FEET. PROVIDE SPECIES LIVE OAKS OR CATHEDRAL CULTIVAR | | | INSTEAD OF HIGH RISE CULTIVAR. | | | | | | 5. PROVIDE LOCATIONS AND DETAIL FOR THE REQUIRED | | | STRUCTURAL SOIL UNDER HARDSCAPE PER SECTION 94-113 AND | | | PROVIDE THE TYPICAL DETAIL FOR INSTALLATION. THE DETAIL | | | PROVIDED ON SHEET LP-6 DOES NOT MATCH CITY DETAIL. THE | | | AREA MUST BE 9 X14 FT PARALLEL TO THE CURB FOR EACH | | | TREE CONSISTING OF PLANTING AREA AND/OR STRUCTURAL | | | SOIL. ROOT BARRIERS WILL CUT OFF THE STRUCTURAL SOIL, | | | SO UTILITIES MUST BE COORDINATED I.E. GAS LINE ALONG | | | FERN. | | | | | | 6. MAKE THE FOLLOWING CORRECTIONS ON THE PLANT LIST: | | | ??? JAPANESE BLUEBERRY TOPIARY AND GREEN ISLAND FICUS | | | TOPIARY MUST BE MOVED FROM THE TREE LIST TO THE SHRUB | | | LIST. | | | ??? COCONUT IS NOT A FLORIDA NATIVE PLANT. | | | ??? CLUSIA GUTTIFERA CAN BE COUNTED AS A FLORIDA NATIVE | | | PLANT. | | | | | | | | | | | | 7. SHOW ALL EXISTING AND PROPOSED WATER AND SEWER AND | | | DRAINAGE LINES CLEARLY ON THE LANDSCAPE PLAN. SHOW | | | LOCATIONS OF BACKFLOWS AND ADJUST LOCATIONS OF UTILITY | | | LINES TO RESOLVE CONFLICTS WITH EXISTING AND PROPOSED | | | TREES AND LANDSCAPING. DRAINAGE LINES APPEAR TO BE IN | | | CONFLICT WITH TREES IN THE PUBLIC OPEN SPACE PLAZA. | | | | | | | | | 8. PROVIDE SCREENING HEDGES FOR ALL GROUND MOUNTED | | | VALVES AND EQUIPMENT AND ADD A NOTE THAT ALL EQUIPMENT | | | WILL BE SCREENED. | | | | | | | | | CONDITIONS OF APPROVAL | | | 1. PRIOR TO THE REMOVAL OR RELOCATION OF ANY TREES ON | | | THE PROPERTY, A TREE ALTERATION PERMIT SHALL BE | | | SUBMITTED, REVIEWED AND APPROVED BY THE DEVELOPMENT | | | SERVICES DEPARTMENT, PLANNING DIVISION. | | | | | | 2. THE APPLICANT, SUCCESSORS AND ASSIGNS SHALL BE | | | RESPONSIBLE FOR THE PERMITTING AND INSTALLATION OF THE | | | RIGHT OF WAY LANDSCAPING AND IRRIGATION APPROVED WITH | | | THIS PETITION. | | | | | | | | | 3. THE APPLICANT, SUCCESSORS AND ASSIGNS SHALL BE | | | RESPONSIBLE FOR THE MAINTENANCE OF THE STREETSCAPE | | | LANDSCAPING AND IRRIGATION. THIS WILL BE THROUGH A | | | SEPARATE MAINTENANCE AGREEMENT WITH THE CITY. | | | |
|
|
| Review Stop |
PARK |
PARKING |
| Rev No |
1 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
|
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
POLICE |
POLICE |
| Rev No |
1 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
|
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
PU |
PUBLIC UTILITIES |
| Rev No |
2 |
Status |
P |
Date |
11-14-2022 |
|
|
Cont ID |
|
| Sent By |
mtechnow |
Date |
11-14-2022 |
Time |
17:21 |
Rev Time |
0.00 |
| Received By |
mtechnow |
Date |
11-14-2022 |
Time |
17:21 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
PU |
PUBLIC UTILITIES |
| Rev No |
1 |
Status |
F |
Date |
10-13-2022 |
|
|
Cont ID |
|
| Sent By |
mtechnow |
Date |
10-13-2022 |
Time |
12:13 |
Rev Time |
0.00 |
| Received By |
mtechnow |
Date |
10-13-2022 |
Time |
12:11 |
Sent To |
|
|
| Notes |
| 2022-10-13 12:12:56 | 1) | | | -10??? CAS WM ON EVERNIA FROM 1927, EXTEND WATERMAIN TO | | | VALVE EAST OF ROSEMARY. | | | -CALL TO REMOVE EXISTING 10??? WM ON DEMOLITION PLAN. | | | -CORRECT CALL OUT AT BOTTOM OF SHEET C-300 | | | -CALL TO CUT AND CAP UNUSED SERVICES AT THE MAIN. | | | -SHOW ALL EXISTING SANITARY AND WATER SERVICES | | | -SHOW UNDERGROUND FRANCHISE UTILITIES | | | |
|
|
| Review Stop |
PU-CS |
PUBLIC UTILITIES CUSTOMER SRVC |
| Rev No |
2 |
Status |
P |
Date |
11-14-2022 |
|
|
Cont ID |
|
| Sent By |
mhurley |
Date |
11-14-2022 |
Time |
11:41 |
Rev Time |
0.00 |
| Received By |
mhurley |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2022-11-14 11:40:53 | -BACKFLOW ASSEMBLIES APPEAR TO BE MISLABELED AND NEED | | | TO BE UPDATED AT ENGINEERING DEVELOPMENT SUBMITTAL. | | | -LIGHT POLE LOCATIONS ON CIVIL PLANS NEED TO BE | | | VERIFIED AND UPDATED AT ENGINEERING DEVELOPMENT | | | SUBMITTAL. | | | -WATER METER VAULT LOCATION MAY NEED ADJUSTMENT AT | | | ENGINEERING DEVELOPMENT SUBMITTAL. | | | -APPLICANT TO MAINTAIN WATER METER VAULT IN ACCORDANCE | | | WITH MAINTENANCE AGREEMENT. | | | RESPECTFULLY, | | | MARK HURLEY [email protected] |
|
|
| Review Stop |
PU-CS |
PUBLIC UTILITIES CUSTOMER SRVC |
| Rev No |
1 |
Status |
F |
Date |
10-07-2022 |
|
|
Cont ID |
|
| Sent By |
mhurley |
Date |
10-07-2022 |
Time |
13:46 |
Rev Time |
0.00 |
| Received By |
mhurley |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2022-10-07 13:45:36 | PLEASE PROVIDE WRITTEN RESPONSES TO THE FOLLOWING: | | | -ON SHEET C300 SOME OF THE CALLOUTS ARE GOING OFF THE | | | BOTTOM AND SIDE OF PAGE AND UNREADABLE. PLEASE MAKE | | | READABLE. | | | -DRY UTILITIES IN ALLEY MAY BE MORE NUMEROUS THAN SHOWN | | | ON DEMO PLAN. | | | -VERIFY THAT REMOVAL OF UTILITIES IN ALLEY WILL NOT | | | NEGATIVELY AFFECT 360 ROSEMARY UTILITY SERVICE. | | | -PROPOSED 10 INCH WATER MAIN CANNOT BE PVC. UPDATE TO | | | DIP. | | | -SHOW AND LABEL ALL EXISTING WATER MAIN VALVES. THERE | | | MAY ALSO BE A NEW GATE VALVE SEVERAL FEET WEST OF | | | PROPOSED WATER SERVICE TAP. | | | -PROPOSED 6 INCH WATER METER IS NOT APPROVED | | | UNDERGROUND IN VAULT. LABEL ABOVE GROUND VIA STANDARD | | | DETAIL WS3 REV2019. | | | -10 INCH CAS WM AT WEST SIDE OF EVERNIA MAY BE NEWER | | | INSTALLED DIP. | | | -PROPERTY OWNER WOULD BE REQUIRED TO RECORD BACKFLOW | | | COVENANT AS A CONDITION OF WATER SERVICE. | | | -WPB UTILITIES RECOMMENDS INSTALLING PARALLEL DOMESTIC | | | BACKFLOW ASSEMBLIES TO MINIMIZE WATER OUTAGES DURING | | | BACKFLOW MAINTENANCE. | | | -ON DEMO PLAN SHOW REMOVAL OF WATER SERVICE FOR | | | EXISTING BUILDING NEAR NORTHWEST AREA OF PROPERTY. | | | -SUBMIT SEPARATE LANDSCAPING SHEET OF GROUND FLOOR | | | SHOWING UTILITIES AND PLANTS (TREES AND BUSHES). SHEET | | | SHOULD SHOW SUFFICIENT CLEARANCE DISTANCE BETWEEN | | | PLANTS AND UTILITIES. SOME UTILITIES ARE SHOWN ON | | | CURRENT LANDSCAPING PLANS, BUT THE LOCATIONS DO NOT | | | MATCH ENGINEERING PLANS. | | | -SHEET C300, LABEL WHAT IS HAPPENING TO THE TALL | | | UTILITY POLE AND OVERHEAD UTILITY ON FERN STREET. | | | -CURRENTLY THERE IS A DO NOT ENTER SIGN AND LEFT TURN | | | ARROW GOING EAST ON EVERNIA ST. WILL THAT CHANGE? | | | -C902 SHOWS VEHICLE USING DRIVEWAY OF 360 ROSEMARY | | | PROPERTY. IS THERE A CROSS ACCESS EASEMENT AGREEMENT? | | | ALSO IS THAT THE PROPOSED ENTRANCE OF THE SERVICE AREA? | | | -WOULD NEED PAVEMENT RESTORATION ON EVERNIA DUE TO | | | UTILITY WORK. | | | -WILL NEW ROAD NEAR EAST PROPERTY LINE HAVE AN ACCESS | | | EASEMENT? | | | RESPECTFULLY, | | | MARK HURLEY [email protected] |
|
|
| Review Stop |
PW |
PUBLIC WORKS |
| Rev No |
2 |
Status |
P |
Date |
03-21-2023 |
|
|
Cont ID |
|
| Sent By |
|
Date |
03-21-2023 |
Time |
|
Rev Time |
0.00 |
| Received By |
|
Date |
03-21-2023 |
Time |
|
Sent To |
|
|
| Notes |
| 2023-03-21 10:41:50 | CONDITIONS OF APPROVAL: | | | | | | 1- SANITATION COLLECTION SERVICE FOR LARGE SIZE | | | CONTAINERS (I.E. FOR 8+ CUB YD COMPACTOR, OR ROLL-OFF | | | CONTAINER) SHALL BE PROVIDED FROM CITY OF WEST PALM | | | BEACH APPROVED VENDORS LISTED AT HTTPS://WWW.WPB.ORG/GO | | | VERNMENT/PUBLIC-WORKS/SANITATION/COMMERCIAL-DUMPSTERS-C | | | OMPACTORS. | | | 2- BEFORE THE FINAL SITE PLAN SUBMITTAL, PROVIDE A | | | SERVICE AVAILABILITY LETTER FROM THE APPROVED HAULER | | | FOR THE GARBAGE COLLECTION SERVICE BASED ON THE | | | PROPOSED AUTOTURN PLAN FOR THE SANITATION COLLECTION | | | VEHICLE. | | | | | | | | | MATT HEJAZI | | | DEPT. PF PUBLIC WORKS | | | [email protected] |
|
|
| Review Stop |
PW |
PUBLIC WORKS |
| Rev No |
1 |
Status |
F |
Date |
10-05-2022 |
|
|
Cont ID |
|
| Sent By |
|
Date |
10-05-2022 |
Time |
|
Rev Time |
|
| Received By |
|
Date |
10-05-2022 |
Time |
|
Sent To |
|
|
| Notes |
| 2022-10-05 12:59:56 | PLEASE PROVIDE THE FOLLOWINGS: | | | 1- LOS (LEVEL OF SERVICE ANALYSIS) TO REFLECT THE SOLID | | | WASTE VOLUME PRODUCED ALONG WITH THE SIZE, TYPE AND | | | QUANTITY OF THE CONTAINER (I.E. DUMPSTER/COMPACTOR) | | | THAT WILL BE UTILIZED FOR THE SANITATION SERVICE. | | | 2- DETAILS FOR SANITATION SERVICE (I.E. SOLID WASTE | | | CONTAINER(S) TYPE, COLLECTION LOCATION, ETC.). | | | 3- AUTOTURN EXHIBIT WITH DYNAMIC ENVELOPE AND THE | | | VEHICLE'S WHEEL PATH IDENTIFIED WITH DIFFERENT COLORS | | | FOR THE SANITATION SERVICE, FRONT LOADER TRUCK WITH THE | | | FOLLOWING SPECS: | | | - DUAL AXLES | | | - TRUCK LENGTH: 35 FT | | | - TRUCK WIDTH: 11 FT | | | - TURNING RADIUS: | | | - SAE TURNING RADIUS: 32.5 FT | | | - CURB-TO-CURB DIAMETER: 74 FT | | | - WALL-TO-WALL DIAMETER: 86.3 FT | | | 4- DESIGNATED LOCATION FOR THE BULK ITEM PICK UP AND | | | RECYCLING CONTAINERS | | | 5- OWNERS AND/OR OCCUPANTS OF PROPERTY THAT REQUIRE | | | GREASE HAULING SERVICES SHALL ENSURE THAT THEIR GREASE | | | TANKS OR CONTAINERS REMAIN CLEAN, AND ARE ENCLOSED AND | | | NOT IN PUBLIC VIEW. | | | 6- IN CASE OF PROPOSING ADDITION OF ANY NEW CAN(S) IN | | | THE CITY`S RIGHT-OF-WAY , THE LOCATION AND QUANTITY OF | | | THE CAN(S) SHALL BE REVIEWED AND APPROVED BY PUBLIC | | | WORKS DEPARTMENT AND THE CAN(S) SHALL BE TYPE, SIZE AND | | | COLOR APPROVED BY PUBLIC WORKS DEPARTMENT. THE BUILDING | | | MAINTENANCE IS RESPONSIBLE TO MAINTAIN AND SERVICE THE | | | CAN(S). | | | 7- ALL THE PARKING STALL PAINTING SHALL COMPLY WITH THE | | | CITY`S MUNICIPAL CODE SECTION 94-485 AND FLORIDA | | | STATUES [553.5041 F.S.]. | | | 8- SIGNAGE PLAN. ALL STRIPING AND SIGNAGE SHALL COMPLY | | | WITH THE LATEST CITY OF WEST PALM BEACH STANDARD | | | DETAILS AND MEET THE M.U.T.C.D. LATEST EDITION. | | | 9- ALL PAVEMENT MARKING , SIGNING AND SIDEWALK DAMAGED | | | DURING CONSTRUCTION SHALL BE RESTORED. | | | | | | | | | | | | MATT HEJAZI | | | DEPT. OF PUBLIC WORKS | | | [email protected] | | | 561-822-2045 | | | | | | |
|
|
| Review Stop |
STORM |
STORMWATER |
| Rev No |
1 |
Status |
F |
Date |
10-12-2022 |
|
|
Cont ID |
|
| Sent By |
tward |
Date |
10-12-2022 |
Time |
23:52 |
Rev Time |
0.00 |
| Received By |
tward |
Date |
10-12-2022 |
Time |
23:54 |
Sent To |
|
|
| Notes |
| 2022-10-12 23:54:24 | THIS IS A CONCEPTUAL LEVEL REVIEW. CONSTRUCTION LEVEL | | | DETAILS, DESIGN CALCULATIONS AND THE POLLUTION | | | PREVENTION PLAN WILL BE REVIEWED AS PART OF THE | | | ENGINEERING DEVELOPMENT APPROVAL AND BUILDING PERMIT | | | APPLICATION PROCESSES. | | | | | | THE FOLLOWING COMMENTS MUST BE ADDRESSED PRIOR TO SITE | | | PLAN APPROVAL: | | | | | | 1. LABEL ALL UTILITIES (SIZE, MATERIAL). | | | | | | 2. REVIEW SFWMD ERP APPLICATION 140917-4 REGARDING THE | | | MANHOLE SHOWN WITHIN THE RAILROAD TRACKS AND THE PIPES | | | CONNECTED TO THE MANHOLE. THE DEMOLITION PLAN FOR THE | | | BRIGHTLINE STATION PERMIT CALLED FOR THESE TO BE | | | REMOVED. | | | | | | 3. THERE MAY BE A STORM PIPE CONNECTED TO THE NORTH | | | SIDE OF THE CATCH BASIN ON THE NORTH SIDE OF FERN ST. | | | WEST OF THE F.E.C. R/W. | | | | | | 4. IDENTIFY WHERE THE BRICKSLOT TRENCH DRAINS WILL BE | | | CONSTRUCTED. | | | | | | 5. EXPLAIN HOW STORM WATER QUALITY TREATMENT AND PEAK | | | ATTENUATION WILL BE PROVIDED. | | | | | | 6. EXPLAIN WHAT THE WEST PIPE CONNECTED TO STRUCTURE | | | YD-1 IS FOR. | | | | | | 7. IS THE SOLID HATCHING IN THE NORTH-SOUTH ALLEY ALONG | | | THE WEST PROPERTY LINE NECESSARY? IT IS COVERING UP | | | MANY UTILITY LINES IN THE ALLEY. | | | | | | | | | THE FOLLOWING COMMENTS MUST BE ADDRESSED PRIOR TO | | | ISSUANCE OF CONSTRUCTION AUTHORIZATION INCLUDING | | | BUILDING PERMITS AND ENGINEERING DEVELOPMENT APPROVAL. | | | | | | 1. DRAINAGE SYSTEM TO BE DESIGNED TO MEET SFWMD ERP | | | CRITERIA. STORMWATER CALCULATIONS WILL BE REVIEWED WITH | | | THE ENGINEERING PERMIT SUBMITTAL. | | | | | | 2. PROVIDE COPY OF SFWMD ERP PERMIT BEFORE START OF | | | CONSTRUCTION. | | | | | | 3. PROVIDE EROSION AND SEDIMENT CONTROL PLAN WITH THE | | | ENGINEERING PERMIT SUBMITTAL. | | | | | | TRACY WARD, PE | | | SENIOR STORMWATER ENGINEER | | | ENGINEERING SERVICES DEPARTMENT | | | 561-494-1120 (O) | | | [email protected] | | | |
|
|
| Review Stop |
SURVEY |
SURVEYING |
| Rev No |
1 |
Status |
F |
Date |
10-11-2022 |
|
|
Cont ID |
|
| Sent By |
vnoel |
Date |
10-11-2022 |
Time |
08:36 |
Rev Time |
|
| Received By |
vnoel |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2022-10-11 10:10:07 | 1. REPLAT WILL BE REQUIRED. | | | 2. IT APPEARS THAT THE APPLICANT IS REQUESTING THAT THE | | | ALLEY PROCEEDS BE USED TO FUND THE CONNECTOR ROAD AND | | | THAT THE CITY COMPLETE THE ROADWAY PRIOR TO T.C.O. THIS | | | WILL REQUIRE ADMIN. APPROVAL AND AGREEMENT FOR CITY TO | | | CONTRUCT ROADWAY. | | | 3. IS CONNECTOR ROAD TO BE A RIGHT-OF-WAY OR EASEMENT? | | | 4. REMOVE PROPOSED METER ASSEMBLY OUT OF EVERNIA | | | RIGHT-OF-WAY. | | | 5. SHOW PROPOSED NEW FPL POLE AT INTERSECTION OF ALLEY | | | AND RAILROAD. | | | 6. EXISTING SANITARY IN FEC R/W TO BE REMOVED OR | | | GROUTED IN PLACE. | | | 7. DRAINAGE MH EX-1 NOT SHOWN ON SURVEY. | | | 8. IS LINE BETWEEN ST-1 AND EX-3 EXISTING OR PROPOSED? | | | 9. ANY AERIAL ENCROACHMENTS INTO RIGHTS-OF-WAY WILL | | | REQUIRE AN EASEMENT. |
|
|
| Review Stop |
TRAFFIC |
TRAFFIC ENGINEERING |
| Rev No |
2 |
Status |
F |
Date |
12-21-2022 |
|
|
Cont ID |
|
| Sent By |
|
Date |
12-21-2022 |
Time |
|
Rev Time |
0.00 |
| Received By |
|
Date |
12-21-2022 |
Time |
|
Sent To |
|
|
| Notes |
| 2022-12-21 17:36:36 | | | | 1) PARTIALLY SATISFIED. PROVIDE A FULL DETAILED TRAFFIC | | | STUDY. SEE VALET OPERATIONS COMMENTS. | | | 2) VALET QUEUE ANALYSIS NEEDS TO PROVIDE A DETAILED | | | NARRATIVE AND MORE ELABORATION ON THE ASSUMED | | | PARAMETERS AND HOW THEY HAVE BEEN CALCULATED. PROVIDE A | | | BREAKDOWN OF THE ACTUAL TIMING FOR EACH | | | PICK-UP/DROP-OFF OPERATION, FOR EXAMPLE: XX SECONDS TO | | | RECEIVE/HAND-OVER KEYS, XX TO DRIVE VEHICLE TO/FROM THE | | | GARAGE, XX FOR THE VALET TO WALK TO/FROM THE PODIUM. | | | ESPECIALLY CONSIDERING THE VALET PARKING STALLS BEING | | | LOCATED ON THE TOP FLOORS OF THE GARAGE | | | 3) WHAT IS THE WIDTH OF THE PROPOSED DROP-OFF LOCATION | | | ON FERN ST? NOTE: BECAUSE OF THE ADJACENCY TO THE BIKE | | | LANE IT IS NOT RECOMMENDED, AND EVEN IF APPROVED, A | | | GENEROUS SAFETY BUFFER WOULD NEED TO BE PROVIDED | | | 4) WHERE ARE THE VALET PICK-UP LOCATIONS? | | | 5) PARTIALLY SATISFIED. PROVIDE COUNTY TPS LETTER, ONCE | | | RECEIVED | | | 6) PARTIALLY SATISFIED. PROVIDE TRANSPORTATION DEMAND | | | MANAGEMENT (TDM) MEASURES. AN INITIAL SET OF MEASURES | | | AND METHODOLOGIES SHOULD BE DISCUSSED BY ENGINEERING | | | PERMITTING, AND FINALIZED PRIOR TO TCO | | | 7) SATISFIED. PROVIDE AUTOTURN ANALYSIS FOR GARBAGE | | | TRUCK AND/OR SERVICE VEHICLES DRIVING IN AND OUT OF THE | | | PROPOSED DEVELOPMENT WITH VEHICLE DYNAMIC ENVELOPES AND | | | WHEEL PATHS CLEARLY DISTINCT AND DEFINED IN DIFFERENT | | | COLORS. PROVIDE THE ANALYSIS IN A SEPARATE SHEET. SUCH | | | PLAN(S) CONTAINING THE ANALYSIS ARE PART OF THE | | | TRANSPORTATION REVIEW AND SHOULD BE NAMED ACCORDINGLY | | | (E.G. T1.2, T-3.0). CURRENT ANALYSIS IS INSUFFICIENT. | | | 8) SHEET T-110 ??? TRUCK WHEELS AND DYNAMIC ENVELOPE | | | PATHS SHOW ENCROACHMENTS BY THE FERN ST DRIVEWAY. | | | PLEASE REVISE | | | 9) SATISFIED. PROVIDE A PARKING TABLE SHOWCASING THE | | | NUMBER OF REQUIRED AND PROVIDED PARKING SPACES, | | | INCLUSIVE OF ADA AND BICYCLE ONES | | | 10) THE NUMBER OF PROVIDED PARKING SPACES ARE LESS THAN | | | REQUIRED. IS A VARIANCE OR WAIVER BEING REQUESTED? | | | 11) SATISFIED. ARE THERE ANY GATES PROPOSED? IF SO, | | | CLEARLY SHOWCASE THE REQUIRED 20 FEET SETBACK DISTANCE | | | FROM THE BACK OF THE SIDEWALK | | | 12) PARTIALLY SATISFIED. IS VALET SERVICE PROPOSED? IF | | | SO, PROVIDE A DETAILED OPERATIONAL ANALYSIS. ALSO, ANY | | | VALET OPERATIONS SHOULD BE KEPT INTERNAL TO THE | | | PROPERTY, NO PICK-UP/DROP-OFF ON PUBLIC RIGHT-OF-WAY. | | | VALET OPERATIONS MUST BE VALIDATED AT PPRC STAGE, AS | | | THE PROPOSED SITE DESIGN MAY BE SIGNIFICANTLY IMPACTED | | | IN THE CASE CURRENT VALET PLANS ARE NOT APPROVED | | | 13) SATISFIED. DOES THE QUADRILLE PLAZA DR EXTENSION | | | COMPLY WITH FEDERAL RAILROAD ADMINISTRATION | | | REQUIREMENTS IN TERM OF DISTANCE FROM RAILROAD TRACKS | | | AND GATE ARMS? | | | 14) PARTIALLY SATISFIED. PROVIDE THE NUMBER OF METERED | | | STALLS THAT ARE BEING REMOVED OR RELOCATED. HAS PARKING | | | DEPARTMENT BEEN NOTIFIED OR APPROVED THE REMOVAL? | | | 15) PARTIALLY SATISFIED. THERE IS A LACK OF ON-STREET | | | PARKING AND PICK-UP/DROP OFF ZONES IN THE AREA; | | | MOREOVER, THE PROPOSED DEVELOPMENT IS REMOVING SEVERAL | | | STALLS ON FERN AND EVERNIA. THUS, PARKING SHOULD BE | | | INSTALLED ALONG THE PROPOSED NEW ROADWAY. PLEASE | | | PROVIDE CODE REFERENCE AND A DRAFT DRAWING SHOWCASING | | | LIMITING SETBACKS, IF ANY | | | 16) BECAUSE OF THE POTENTIAL CONGESTION IN THE AREA DUE | | | TO SEVERAL FUTURE DEVELOPMENTS UNDER REVIEW OR ALREADY | | | APPROVED IN THE VICINITY OF THE PROPOSED ONE, THE CITY | | | IS RECOMMENDING ONE-WAY CIRCULATION FOR THE QUADRILLE | | | PLAZA DR EXTENSION, WITH A PROPENSITY FOR THE | | | SOUTHBOUND DIRECTION. SUCH MODIFICATION WILL ALSO ALLOW | | | ESTABLISHING PERMANENT OR TEMPORARY PARKING STALLS, | | | WHICH WOULD ALLEVIATE THE ALREADY CRITICAL ON-STREET | | | PARKING CONDITIONS. PLEASE REVISE THE SITE PLANS | | | ACCORDINGLY | | | 17) TO FORBID LEFT-TURN MOVEMENTS AND PROPERLY | | | CHANNELIZE THE SOUTHBOUND TRAFFIC ALONG THE QUADRILLE | | | PLAZA DR EXTENSION, PLEASE IMPLEMENT A TRAFFIC ISLAND | | | AT THE FERN ST INTERSECTION AND REVISE THE SITE PLANS | | | ACCORDINGLY | | | 18) SATISFIED. EXPLAIN THE USE OF THE PARKING AREA | | | ALONG FERN | | | 19) SATISFIED. EXPLAIN THE USE OF THE STRETCH OF ROAD | | | NORTH OF THE SOUTH-WESTERN SERVICE DRIVEWAY | | | 20) SATISFIED. PROVIDE A CIRCULATION DIAGRAM FOR LEVEL | | | 2 | | | 21) SATISFIED. THE SINGLE ELECTRIC CAR PARKING ON LEVEL | | | 2 NEARBY THE ACCESS GATES IS NOT FEASIBLE, EITHER | | | REMOVE IT OR PROVIDE A TURN-AROUND SPACE | | | 22) PARTIALLY SATISFIED. SHOWCASE AND INSERT THE VALUE | | | FOR EACH SLOPE ON LEVEL 1. SHEET A1.01. THE MAIN | | | PARKING RAMP MAY NEED A TRANSITION DUE TO THE SLOPE | | | BEING GREATER THAN 14% | | | 23) SATISFIED. IS THERE A SLOPE BY THE GARAGE ENTRY | | | GATES ON LEVEL 2? SHEET A1.02 | | | 24) SATISFIED. INSTALL AND SHOW DIRECTIONAL ARROW | | | PAVEMENT MARKINGS THROUGHOUT THE GARAGE FLOORS | | | 25) SATISFIED. PER CITY CODE SEC 94-111(C)(1): IN THOSE | | | CASES WHERE THE SIDE OF ANY STALL IS ADJACENT TO A | | | WALL, FENCE, BUILDING, OR OTHER PHYSICAL OBSTRUCTION, | | | THE STALL WIDTHS SHALL BE INCREASED BY A MINIMUM OF ONE | | | FOOT. WHERE THERE IS AN OBSTRUCTION ON BOTH SIDES OF | | | THE STALL, THE STALL WIDTHS SHALL BE INCREASED BY A | | | MINIMUM OF TWO FEET. PROVIDE DIMENSIONS FOR EVERY STALL | | | NEARBY A WALL OR OBSTRUCTION IN SHEET A1.02 TO A1.06. | | | 26) SATISFIED. PROVIDE A MINIMUM OF 8-FEET WIDE | | | PEDESTRIAN WALKABLE AREA THROUGHOUT THE PROPOSED | | | DEVELOPMENT. PROVIDE 15-FEET WIDE SIDEWALK ALONG | | | EVERNIA, SO TO STAY CONSISTENT WITH THE WESTERN PORTION | | | FRONTING THE 360 BUILDING. THIS IS CLEARLY SHOWN IN | | | SHEET R0.02. | | | 27) PARTIALLY SATISFIED. THE EXISTING BICYCLE LANE | | | CONFIGURATION SHOULD BE UNCHANGED. THE 2-FEET BUFFER | | | BETWEEN THE EDGE OF THE BIKE LANE AND THE EXISTING | | | STALLS/PROPOSED NEW CURB MUST BE KEPT. SHOWCASE SUCH | | | DIMENSION IN THE TRANSPORTATION SITE PLAN. PER COMMENT | | | #3, FURTHER DISCUSSION AND POTENTIAL REVISION NEEDED | | | 28) PARTIALLY SATISFIED. INSTALL SHARROW MARKINGS ALONG | | | THE NEW ROADWAY. PLEASE INSTALL THEM AT THE MID-BLOCK | | | POINT AS WELL | | | 29) PARTIALLY SATISFIED. IF FEASIBLE, PROVIDE A | | | PEDESTRIAN CROSSING ON FERN, JUST EAST OF THE QUADRILLE | | | PLAZA DR EXTENSION. PLEASE SHOWCASE THE LANDING RAMPS | | | ON BOTH SIDE OF THE ROAD (NOTE: THERE ARE A FIRE | | | HYDRANT AND A PALM TREE ON THE SOUTH SIDE OF FERN ST, | | | PLEASE MARK THEM ON THE PLAN) | | | 30) PARTIALLY SATISFIED. PROVIDE A MID-BLOCK CROSSING | | | ON FERN, JUST EAST OF THE SERVICE DRIVEWAY. PLEASE | | | ELABORATE ON THE WARRANT JUSTIFICATION | | | 31) PARTIALLY SATISFIED. PROVIDE A MID-BLOCK CROSSING | | | ON THE QUADRILLE PLAZA DR EXTENSION. PLEASE ELABORATE | | | ON THE WARRANT JUSTIFICATION | | | 32) SATISFIED. PLEASE PROVIDE THE DIRECTIONALITY FOR | | | EACH OF THE SERVICE DRIVEWAYS. ARE THEY ONE-WAY OR | | | TWO-WAY? | | | | | | VALERIO ORICCHIO | | | CITY TRANSPORTATION ENGINEER | | | 561-494-1092 | | | [email protected] | | | | | | |
|
|
| Review Stop |
TRAFFIC |
TRAFFIC ENGINEERING |
| Rev No |
1 |
Status |
F |
Date |
10-13-2022 |
|
|
Cont ID |
|
| Sent By |
|
Date |
10-13-2022 |
Time |
|
Rev Time |
|
| Received By |
|
Date |
10-13-2022 |
Time |
|
Sent To |
|
|
| Notes |
| 2022-10-13 03:19:24 | TRAFFIC COMMENTS | | | 1) PROVIDE A FULL DETAILED TRAFFIC STUDY | | | 2) PROVIDE COUNTY TPS LETTER | | | 3) PROVIDE TRANSPORTATION DEMAND MANAGEMENT (TDM) | | | MEASURES | | | SITE COMMENTS | | | 4) PROVIDE AUTOTURN ANALYSIS FOR GARBAGE TRUCK AND/OR | | | SERVICE VEHICLES DRIVING IN AND OUT OF THE PROPOSED | | | DEVELOPMENT WITH VEHICLE DYNAMIC ENVELOPES AND WHEEL | | | PATHS CLEARLY DISTINCT AND DEFINED IN DIFFERENT COLORS. | | | PROVIDE THE ANALYSIS IN A SEPARATE SHEET. SUCH PLAN(S) | | | CONTAINING THE ANALYSIS ARE PART OF THE TRANSPORTATION | | | REVIEW AND SHOULD BE NAMED ACCORDINGLY (E.G. T1.2, | | | T-3.0). CURRENT ANALYSIS IS INSUFFICIENT. | | | 5) PROVIDE A PARKING TABLE SHOWCASING THE NUMBER OF | | | REQUIRED AND PROVIDED PARKING SPACES, INCLUSIVE OF ADA | | | AND BICYCLE ONES | | | 6) ARE THERE ANY GATES PROPOSED? IF SO, CLEARLY | | | SHOWCASE THE REQUIRED 20 FEET SETBACK DISTANCE FROM THE | | | BACK OF THE SIDEWALK | | | 7) IS VALET SERVICE PROPOSED? IF SO, PROVIDE A DETAILED | | | OPERATIONAL ANALYSIS. ALSO, ANY VALET OPERATIONS SHOULD | | | BE KEPT INTERNAL TO THE PROPERTY, NO PICK-UP/DROP-OFF | | | ON PUBLIC RIGHT-OF-WAY | | | 8) DOES THE QUADRILLE PLAZA DR EXTENSION COMPLY WITH | | | FEDERAL RAILROAD ADMINISTRATION REQUIREMENTS IN TERM OF | | | DISTANCE FROM RAILROAD TRACKS AND GATE ARMS? | | | 9) PROVIDE THE NUMBER OF METERED STALLS THAT ARE BEING | | | REMOVED OR RELOCATED | | | 10) THERE IS A LACK OF ON-STREET PARKING AND | | | PICK-UP/DROP OFF ZONES IN THE AREA; MOREOVER, THE | | | PROPOSED DEVELOPMENT IS REMOVING SEVERAL STALLS ON FERN | | | AND EVERNIA. THUS, PROVIDE ON-STREET METERED PARKING | | | ALONG THE PROPOSED NEW ROADWAY | | | 11) EXPLAIN THE USE OF THE PARKING AREA ALONG FERN | | | 12) EXPLAIN THE USE OF THE STRETCH OF ROAD NORTH OF THE | | | SOUTH-WESTERN SERVICE DRIVEWAY | | | 13) PROVIDE A CIRCULATION DIAGRAM FOR LEVEL 2 | | | 14) THE SINGLE ELECTRIC CAR PARKING ON LEVEL 2 NEARBY | | | THE ACCESS GATES IS NOT FEASIBLE, EITHER REMOVE IT OR | | | PROVIDE A TURN-AROUND SPACE | | | 15) SHOWCASE AND INSERT THE VALUE FOR EACH SLOPE ON | | | LEVEL 1. SHEET A1.01 | | | 16) IS THERE A SLOPE BY THE GARAGE ENTRY GATES ON LEVEL | | | 2? SHEET A1.02 | | | 17) INSTALL AND SHOW DIRECTIONAL ARROW PAVEMENT | | | MARKINGS THROUGHOUT THE GARAGE FLOORS | | | 18) PER CITY CODE SEC 94-111(C)(1): IN THOSE CASES | | | WHERE THE SIDE OF ANY STALL IS ADJACENT TO A WALL, | | | FENCE, BUILDING, OR OTHER PHYSICAL OBSTRUCTION, THE | | | STALL WIDTHS SHALL BE INCREASED BY A MINIMUM OF ONE | | | FOOT. WHERE THERE IS AN OBSTRUCTION ON BOTH SIDES OF | | | THE STALL, THE STALL WIDTHS SHALL BE INCREASED BY A | | | MINIMUM OF TWO FEET. PROVIDE DIMENSIONS FOR EVERY STALL | | | NEARBY A WALL OR OBSTRUCTION IN SHEET A1.02 TO A1.06. | | | 19) PROVIDE A MINIMUM OF 8-FEET WIDE PEDESTRIAN | | | WALKABLE AREA THROUGHOUT THE PROPOSED DEVELOPMENT. | | | PROVIDE 15-FEET WIDE SIDEWALK ALONG EVERNIA, SO TO STAY | | | CONSISTENT WITH THE WESTERN PORTION FRONTING THE 360 | | | BUILDING. THIS IS CLEARLY SHOWN IN SHEET R0.02. | | | 20) THE EXISTING BICYCLE LANE CONFIGURATION SHOULD BE | | | UNCHANGED. THE 2-FEET BUFFER BETWEEN THE EDGE OF THE | | | BIKE LANE AND THE EXISTING STALLS/PROPOSED NEW CURB | | | MUST BE KEPT. SHOWCASE SUCH DIMENSION IN THE | | | TRANSPORTATION SITE PLAN | | | 21) INSTALL SHARROW MARKINGS ALONG THE NEW ROADWAY | | | 22) IF FEASIBLE, PROVIDE A PEDESTRIAN CROSSING ON FERN, | | | JUST EAST OF THE QUADRILLE PLAZA DR EXTENSION | | | 23) PROVIDE A MID-BLOCK CROSSING ON FERN, JUST EAST OF | | | THE SERVICE DRIVEWAY | | | 24) PROVIDE A MID-BLOCK CROSSING ON THE QUADRILLE PLAZA | | | DR EXTENSION | | | 25) PLEASE PROVIDE THE DIRECTIONALITY FOR EACH OF THE | | | SERVICE DRIVEWAYS. ARE THEY ONE-WAY OR TWO-WAY? | | | | | | VALERIO ORICCHIO | | | CITY TRANSPORTATION ENGINEER | | | 561-494-1092 | | | [email protected] | | | | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
03-29-2023 |
|
|
Cont ID |
|
| Sent By |
ckimmerl |
Date |
03-29-2023 |
Time |
16:47 |
Rev Time |
0.00 |
| Received By |
ckimmerl |
Date |
03-29-2023 |
Time |
16:47 |
Sent To |
|
|
| Notes |
| 2023-03-29 16:45:15 | | | | CONDITIONS FOR APPROVAL | | | | | | 1. PRIOR TO THE REMOVAL OR RELOCATION OF ANY TREES ON | | | THE PROPERTY, A TREE ALTERATION PERMIT SHALL BE | | | SUBMITTED, REVIEWED AND APPROVED BY THE DEVELOPMENT | | | SERVICES DEPARTMENT, PLANNING DIVISION. | | | | | | 2. THE APPLICANT, SUCCESSORS AND ASSIGNS SHALL BE | | | RESPONSIBLE FOR THE PERMITTING AND INSTALLATION OF THE | | | STREET TREES AND RIGHT OF WAY LANDSCAPING AND | | | IRRIGATION APPROVED WITH THIS PETITION. | | | | | | 3. THE APPLICANT, SUCCESSORS AND ASSIGNS SHALL BE | | | RESPONSIBLE FOR THE MAINTENANCE OF THE STREET TREES AND | | | RIGHT OF WAY LANDSCAPING AND IRRIGATION. THIS WILL BE | | | THROUGH A SEPARATE MAINTENANCE AGREEMENT WITH THE CITY. | | | | | | CHRIS KIMMERLY, AICP | | | URBAN DESIGN PLANNER | | | 822-1426 [email protected] | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
12-13-2022 |
|
|
Cont ID |
|
| Sent By |
ckimmerl |
Date |
12-13-2022 |
Time |
10:38 |
Rev Time |
0.00 |
| Received By |
ckimmerl |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2022-12-13 10:38:44 | 1. VARIANCE REQUEST FOR BUILDING FOOTPRINT LEVEL 6-7 | | | (MAX. 60%) PROPOSED AT 63%. PER SECTION 95-54 (D.)(4).) | | | UNAUTHORIZED VARIANCES. THE DAC IS NOT AUTHORIZED TO | | | GRANT VARIANCES FOR ANY OF THE FOLLOWING: (E.) AN | | | INCREASE IN THE MAXIMUM BUILDING FOOTPRINT ABOVE THE | | | MAXIMUM FOOTPRINT ALLOWED BY THE URBAN REGULATIONS. | | | | | | RESPONSE: THE APPLICANT BELIEVES A VARIANCE CAN BE | | | GRANTED. WE HAVE REQUESTED A MEETING TO DISCUSS. | | | | | | ZONING REVIEW 12/2/22 ??? [SATISFIED] APPLICANT NO | | | LONGER ASKING FOR FOOTPRINT VARIANCE, VARIANCE IS FROM | | | SECTION 94-132(E.)(3.)(C.) FOR FUTURE ROW AREA IN | | | BUILDING CALCULATIONS. | | | | | | 2. WHAT IS THE TOTAL SQUARE FOOTAGE FOR OFFICE SPACE | | | AND RETAIL? JUSTIFICATION LETTER STATES OFFICE AT | | | 425,798 SF; SHEET A0.01 STATES 378,137 SF; PLEASE | | | CLARIFY SO STAFF MAY VERIFY PARKING REQUIREMENTS. | | | RETAIL IN JUSTIFICATION LETTER IS 9,369 SF; SHEET A0.01 | | | STATES 9,161 SF. PARKING COUNT WILL HAVE TO BE ADJUSTED | | | TO MEET RESPECTIVE REQUIREMENTS, THE RATIOS PER USE | | | PROVIDED ON A0.01 ARE CORRECT. | | | | | | RESPONSE: THE GROSS BUILDING AREA PER USE AND OVERALL | | | FAR IS CLARIFIED ON REVISED SHEET A0.01 AND THE | | | JUSTIFICATION STATEMENT. SEE ALSO SHEET A0.10 BUILDING | | | AREAS FOR FULL GROSS BUILDING AREA TABULAR PER USE. | | | | | | PER SECTION 94-111 OF THE ZONING CODE, PARAGRAPH B.2., | | | ???PARKING REQUIREMENT CALCULATIONS SHALL BE BASED ON | | | NET INTERIOR AREA.??? NET INTERIOR AREA (OFFICE) OF | | | 378,137 SF IS CORRECT AS SHOWN IN THE PARKING TABULAR | | | TABLE ON SHEET A0.01. NET INTERIOR AREA (RETAIL) OF | | | 9,161 SF IS CORRECT AS SHOWN IN THE PARKING TABULAR | | | TABLE ON SHEET | | | A0.01. SEE ALSO SHEET A0.09 NET INTERIOR AREA FOR FULL | | | TABULAR AND DIAGRAMS. | | | | | | ZONING REVIEW 12/2/22 ??? [NOT SATISFIED] DEFICIENT 180 | | | SPACES FOR OFFICE USE. MIN. REQ. 946 PROVIDING 766. | | | (19% REDUCTION) | | | | | | SEC. 94-485 - ALL SMALL CAR PARKING SPACES SHALL BE | | | MARKED WITH INDIVIDUAL SIGNS STATING "SMALL CARS ONLY." | | | SMALL CAR PARKING SPACES SHALL HAVE DOUBLE STRIPING ON | | | EACH SIDE OF THE SPACE. | | | | | | 3. PLEASE PROVIDE DIMENSIONS OR CALLOUTS SPECIFYING | | | DEPTH OF ALL SETBACKS ON SITE PLANS, FLOOR PLANS, AND | | | ELEVATIONS. MINIMUM AND MAXIMUM SETBACKS SHOW. | | | A. CONDITIONAL SETBACK FOR PARKING USES ABOVE THE 5TH | | | FLOOR; SHEET A1.06 ONLY SHOWS EVERNIA STREET SET BACK | | | (PLEASE LABEL REQUIRED 27 FT FROM BACK OF THE CURB) | | | ZONING REVIEW 12/2/22 ??? [SATISFIED] VARIANCE | | | REQUESTED. | | | | | | B. REQUIRED CONDITIONAL SETBACK ALONG FERN AND | | | QUADRILLE PLAZA DR. IS 31 FT (PLEASE LABEL ON SHEET | | | A1.06 AND A1.07) | | | ZONING REVIEW 12/2/22 ??? [SATISFIED] VARIANCE | | | REQUESTED. | | | | | | C. PLEASE LABEL OR PROVIDE THE FEC ROW ABUTMENT | | | SETBACKS AND CONDITIONAL SETBACKS ON SHEET A0.05 AND | | | A1.01 ONWARD. | | | | | | RESPONSE: DIMENSIONS AND CALLOUTS HAVE BEEN ADDED TO | | | THE DRAWINGS AS REQUESTED. | | | ZONING REVIEW 12/2/22 ??? [SATISFIED] VARIANCE | | | REQUESTED. | | | | | | 4. SHEET A0.08 FAR | | | A. LEVEL 1 FAR- FAR COUNT NEEDS TO INCLUDE STORAGE | | | SPACE ADJACENT TO PARKING RAMP | | | B. LEVEL 2 FAR- PORTION OF NORTHEAST STAIRWELL NOT | | | SHOWN AS IT IS ON A1.02, PORTION NEEDS TO BE COUNTED IN | | | FAR | | | C. MINOR NOTE: SHEET A1.03 DOESN'T SHOW SOUTHERN | | | ELEVATOR AS YELLOW SHADING FOR CIRCULATION | | | D. LEVEL 4 FAR- PORTION OF NORTHWEST STAIRWELL NOT | | | SHOWN AS IT IS ON A1.04, PORTION NEEDS TO BE COUNTED IN | | | FAR | | | E. PENTHOUSE FAR- ROOFTOP ON A1.26 SHOWS UNLABELED ROOM | | | BELOW THE ELEVATOR OVERRUNS, PLEASE LABEL AND IF NOT | | | MECHANICAL, SPACE WILL COUNT TOWARD FAR. | | | | | | RESPONSE: PLEASE SEE SHEETS A0.08, A1.03, AND A1.26 FOR | | | REVISIONS. SEE ALSO UPDATED FAR DATA ON SHEET A0.01. | | | ZONING REVIEW 12/2/22 ??? [SATISFIED] | | | | | | 5. PUBLIC OPEN SPACE REQUIREMENT NEEDS TO BE ADJUSTED. | | | 3% REQUIREMENT FOR LOTS 50,000- 80,000SF; TOTAL | | | REQUIRED 2,292 SF PLUS THE ADDITIONAL 3,501 SF FROM THE | | | ALLEY ABANDONMENT 1:1 REPLACEMENT. TOTAL REQUIRED 5,793 | | | SF. PLEASE ADJUST TABLE ON SHEET A0.06 OR LP-1 TO | | | REFLECT THE CORRECT NUMBER. | | | | | | RESPONSE: PUBLIC OPEN SPACE CALCULATIONS ON SHEETS | | | LP-1, LP-2 AND A0.06 ARE CORRECT. PARCEL 1 + PARCEL 2 + | | | PARCEL 3 AREAS (PER SURVEY) = 26,629 SF + 39,621 SF + | | | 6,656 SF = 72,906 SF X .03 = 2,187 SF. PLUS 3,501 SF | | | (PARCEL 4 AT 1:1) = 5,688 SF TOTAL | | | REQUIRED. | | | ZONING REVIEW 12/2/22 ??? [SATISFIED] | | | | | | 6. WILL THE QUADRILLE PLAZA DRIVE RIGHT-OF-WAY BE A | | | DEDICATED ROW? WHAT IS THE FINAL ROW WIDTH? PLEASE | | | INDICATE ROW LINE ON PLANS, AS IT IMPACTS SETBACKS AND | | | SITE CONFIGURATION. PLEASE PROVIDE DETAILED DIMENSIONS | | | AND CONDITIONS OF THE QUADRILLE PLAZA DR. EXTENSION | | | (SIDEWALK, TRAVEL LANE, LANDSCAPE BUFFERS, | | | PLANTERS/LANDSCAPE BEDS, ETC.) ON SITE AND GROUND FLOOR | | | PLANS, AS IS SHOWN IN CIVIL PLANS. | | | | | | RESPONSE: THE APPLICANT IS OPEN TO DISCUSSING WHETHER | | | IT WILL BE A DEDICATED ROW OR EASEMENT. SEE SHEET A0.05 | | | FOR PROPOSED 60??? ROW FOR QUADRILLE PLAZA DRIVE. A | | | 16??? SETBACK LINE IS SHOWN FROM BACK OF CURB. | | | ZONING REVIEW 12/2/22 ??? [SATISFIED] | | | 60' ROW SHALL BE A DEDICATION OR PUBLIC ACCESS | | | EASEMENT. | | | | | | 7. REMOVAL OF METERED ON-STREET PARKING WILL INCUR A | | | REMOVAL FEE. PERMANENT REMOVAL FEE INCLUDED WITHIN | | | RESOLUTION 191-22, $24,000 PER SPACE. PLEASE SPEAK WITH | | | ED DAVIS- PARKING ADMINISTRATOR FOR ANY QUESTIONS | | | REGARDING THE REMOVAL PROCESS OR FEES. | | | | | | RESPONSE: ACKNOWLEDGED. THE PROJECT WILL REMOVE 11 | | | SPACES AND WORK WITH ED DAVIS AT PARKING ON THIS ISSUE. | | | ZONING REVIEW 12/2/22 ??? [SATISFIED] | | | REMOVAL OF PARKING TO BE DISCUSSED FURTHER WITH PARKING | | | ADMIN. | | | | | | 8. PLEASE NOTE; IN THOSE CASES WHERE THE SIDE OF ANY | | | PARKING STALL IS ADJACENT TO A WALL, FENCE, BUILDING, | | | OR OTHER PHYSICAL OBSTRUCTION, THE STALL WIDTHS SHALL | | | BE INCREASED BY A MINIMUM OF ONE FOOT. WHERE THERE IS | | | AN OBSTRUCTION ON BOTH SIDES OF THE STALL, THE STALL | | | WIDTHS SHALL BE INCREASED BY A MINIMUM OF TWO FEET. | | | | | | RESPONSE: ACKNOWLEDGED. PLEASE SEE SHEETS A1.02 THROUGH | | | A1.05 FOR ADDITIONAL DIMENSIONS. LEVELS 6 AND 7 ARE | | | ENTIRELY VALET PARKING AND UTILIZE FABRICATED STACKERS. | | | ZONING REVIEW 12/2/22 ??? [SATISFIED] | | | | | | 9. HISTORIC PRESERVATION: THE 501 FERN ST. BUILDING IS | | | HISTORICALLY ELIGIBLE, PER THE REQUIREMENT OF SEC. | | | 94-131 THE BUILDING SHALL BE INTEGRATED INTO THE | | | PROJECT AS PART OF THE NEW DEVELOPMENT. IF THE NEW | | | QUADRILLE PLAZA DR. ROW DOES NOT CONSUME THIS BUILDING, | | | BOTH HISTORIC PRESERVATION AND PLANNING STAFF REQUEST | | | THAT THE DESIGN ELEMENTS FROM THE FRONT FACADE OF THE | | | 501 BUILDING IS PRESERVED, REPLICATED, OR INTEGRATED | | | INTO THE GROUND-FLOOR DESIGN OF THE PROPOSED 515 | | | BUILDING AT THIS CORNER. PARTICULARLY THE FLUTED | | | COLUMN-LIKE ELEMENTS AND THE HORIZONTAL STRIATIONS OF | | | THE CORNICE AND ENTRY CANOPY. | | | | | | RESPONSE: THE BUILDING REFERENCED IS IN THE PROPOSED | | | 60??? ROW AND THE BUILDING WILL BE REMOVED. | | | ZONING REVIEW 12/2/22 ??? [PARTIALLY SATISFIED] PER | | | CONVERSATION WITH PLANNING & HISTORIC PRESERVATION | | | STAFF, HAS THERE BEEN ANY ALTERATION OR PROPOSED | | | INCLUSION OF ARCHITECTURAL ELEMENTS OR REFERENCES TO | | | THE REMOVED ELIGIBLE STRUCTURE? | | | | | | 10. PLEASE LABEL AND PROVIDE SIDEWALK DIMENSIONS, AS | | | WELL AS DIMENSIONS FOR PLANTERS/LANDSCAPE AREAS OR | | | ELEMENTS WITHIN THE ROW ON BOTH THE GROUND FLOOR AND | | | SITE PLAN A0.05 AND A0.01; APPEARS TO BE 8-12 FEET | | | CLEAR, STAFF WOULD LIKE TO VERIFY THAT THE 8 FOOT CLEAR | | | PATH IS MAINTAINED. CIVIL PLANS PROVIDE THESE | | | DIMENSIONS. | | | | | | RESPONSE: PLEASE SEE SHEETS A0.05 AND A1.01 FOR | | | ADDITIONAL SIDEWALK AND PLANTER LABELS AND DIMENSIONS | | | ZONING REVIEW 12/2/22 ??? [SATISFIED] | | | | | | 11. SHEET A0.06D FOR THE FA??ADE ARTICULATION | | | COMPLIANCE MATRIX: WEST, ON THE PROVIDED FENESTRATION | | | IT IS NOTED THAT FA??ADE E & G ARE MORE THAN 3 FEET | | | FROM THE LOT LINE; SHOULD THIS READ AS LESS THAN 3 FT.? | | | | | | RESPONSE: NOTE IN MATRIX WAS IN ERROR. FACADES E AND H | | | ARE NON-APPLICABLE AS THEY ARE NON-ACTIVE USE FACADES. | | | THE BALANCE OF THE WEST FACADES ARE ACTIVE USES AND | | | COMPLY. PLEASE SEE REVISED MATRIX, SHEET A0.06D. | | | ZONING REVIEW 12/2/22 ??? [SATISFIED] | | | | | | 12. DUE TO THE SIGNIFICANCE IN SCALE FOR THE PROPOSED | | | DEVELOPMENT PROJECT AND ITS IMPACT ON THE SURROUNDING | | | ROADWAY NETWORK, STAFF REQUESTS THAT TDM STRATEGIES ARE | | | DISCUSSED FOR THIS PROJECT. | | | | | | RESPONSE: SIMILAR TO 360 ROSEMARY, GIVEN THE EVOLVING | | | NATURE OF TRANSPORTATION MANAGEMENT STRATEGIES, THE | | | APPLICANT WILL WORK WITH THE CITY ON A TDM PROGRAM FOR | | | THE PROJECT THAT WILL BE IN PLACE PRIOR TO THE ISSUANCE | | | OF A TCO. | | | ZONING REVIEW 12/2/22 ??? [SATISFIED] TO BE DISCUSSED | | | FURTHER WITH CITY STAFF AND APPLICANT | | | | | | 13. ON THE SHEET A0.06E, PLEASE PROVIDE PROJECTION | | | DIMENSION ON THE HORIZONTAL FEATURES. | | | | | | RESPONSE: PLEASE SEE SHEETS A0.06E, A0.6F, AND A0.6H | | | FOR ADDED DIMENSIONS AT HORIZONTAL FEATURES. | | | | | | ZONING REVIEW 12/2/22 ??? [SATISFIED] | | | | | | 14. QUADRILLE PLAZA DR. EXTENSION SHOULD BE | | | RIGHT-TURN-ONLY AT FERN ST. INTERSECTION, NOT ENOUGH | | | QUEUING OR STACKING SPACE BEFORE THE TRAIN TRACKS. | | | | | | RESPONSE: ACKNOWLEDGED. | | | | | | ZONING REVIEW 12/2/22 ??? [SATISFIED] | | | | | | 15. PLEASE ILLUSTRATE SITE VISIBILITY TRIANGLES SO THAT | | | STAFF MAY VERIFY THAT THERE ARE NO OBSTRUCTIONS AT THE | | | INTERSECTIONS AND DRIVES. | | | | | | RESPONSE: SITE VISIBILITY TRIANGLES HAVE BEEN ADDED TO | | | THE DRAWINGS, AND THE PROPOSED PLANTING HAS BEEN | | | ADJUSTED, SEE SHEET LP-2. | | | | | | ZONING REVIEW 12/2/22 ??? [NOT SATISFIED] SITE | | | VISIBILITY TRIANGLES NEED TO BE ADJUSTED TO BE FROM THE | | | INTERSECTION OF THE PROPERTY LINES AND CORNERS. SEE | | | SEC. 94-305(E.) AND FIGURE X-1. | | | | | | VISIBILITY AT INTERSECTIONS. AT ANY ROAD INTERSECTIONS, | | | VISIBILITY SHALL NOT BE OBSCURED BY THE CONSTRUCTION, | | | PLACEMENT, OR MAINTENANCE OF A STRUCTURE WALL, SIGN, | | | FENCE, BERM, PLANT MATERIAL, SHRUBS, OR ANY SIMILAR | | | ITEM BETWEEN 18 INCHES OR EIGHT FEET IN HEIGHT WITHIN A | | | TRIANGLE BEGINNING AT THE POINT WHERE PROPERTY LINES | | | MEET AT THE CORNER, THEN 20 FEET ALONG THE FRONT | | | PROPERTY LINE, THENCE DIAGONALLY TO A POINT ALONG THE | | | SIDE PROPERTY LINE 20 FEET FROM THE POINT OF BEGINNING, | | | AND THENCE TO THE POINT OF BEGINNING. IN THE EVENT THE | | | CORNER OF AN INTERSECTION IS ROUNDED, THE MEASUREMENT | | | SHALL BEGIN AT THE POINT THE PROPERTY LINES WOULD MEET | | | WITHOUT ROUNDING. (SEE FIGURE X-1) | | | | | | 16. MINOR NOTE: DRAWINGS ONLY PROVIDE ENTRY TO BIKE | | | ROOM FROM OUTSIDE PLAZA, IS THIS INTENTIONAL? | | | | | | RESPONSE: YES, THIS IS INTENTIONAL, IN ORDER TO ALLOW | | | ALL BUILDING OCCUPANTS TO PASS THROUGH THE LOBBY | | | CONTROL AREA. | | | ZONING REVIEW 12/2/22 ??? [NOT SATISFIED] PLEASE | | | CONSIDER ALTERNATIVE ENTRY INTO BUILDING FROM BIKE | | | ROOM, IF THE CONCERN IS SECURITY PLEASE NOTE MANY OF | | | THE INTERNAL CORRIDORS AND BACK OF HOUSE ROOMS ADJACENT | | | TO LOADING OPERATION PROVIDE ACCESS TO THE INTERIOR OF | | | BUILDING. THE BIKE ROOM SHOULD REFLECT A SIMILAR | | | CONDITION, AS CIRCULATING USERS OUTSIDE OF THE BUILDING | | | DISCOURAGES BIKE USE. | | | | | | 17. PLEASE PROVIDE A DETAILED AND DIMENSIONED SCHEMATIC | | | FOR THE INTERNAL BIKE ROOM, SHOWING THE PROPOSED RACKS | | | FROM A3.01 WITH ADEQUATE SPACING/SEPARATION WITHIN THE | | | ROOM. PLEASE PROVIDE THE SPACING DETAILS FOR THE | | | OUTSIDE BIKE RACK AS WELL. | | | | | | RESPONSE: PLEASE SEE SHEET A3.01 / DETAIL 6 FOR INDOOR | | | BIKE ROOM LAYOUT. DIMENSIONS FOR THE OUTSIDE BIKE RACKS | | | HAVE BEEN ADDED, SEE SHEET LH-1. | | | ZONING REVIEW 12/2/22 ??? [SATISFIED] | | | | | | 18. PER SEC. 94-111; A MINIMUM OF ONE SHOWER AND | | | CHANGING FACILITY SHALL BE PROVIDED OR BE AVAILABLE FOR | | | ALL TENANTS AND SHALL BE LOCATED WITHIN THE BUILDING, | | | OR WITHIN 200 FEET OF THE BUILDING ENTRANCE, FOR | | | DEVELOPMENTS GREATER THAN 50,000 SQUARE FEET IN GROSS | | | BUILDING AREA. | | | PLEASE INDICATE ON THE PLANS WHERE THIS SHOWER FACILITY | | | IS LOCATED. | | | | | | RESPONSE: PLEASE SEE SHEET A1.01. THE SHOWER IS | | | INDICATED JUST WEST OF STAIR 1, ALONG THE CORRIDOR | | | CONNECTING THE BUILDING LOBBY TO THE MANAGEMENT OFFICES | | | AND THE LOADING AREA. THE SHOWER IS LOCATED | | | APPROXIMATELY 110 FEET FROM THE MAIN BUILDING ENTRANCE. | | | ZONING REVIEW 12/2/22 ??? [NOT SATISFIED] PLEASE | | | CONSIDER RELOCATING THE SHOWER FACILITY CLOSER TO THE | | | STORAGE ROOM OF THE BIKES, CIRCULATION OF USERS | | | DOESN???T SEEM TO MAKE MUCH SENSE, REQUIRES USERS TO GO | | | AROUND BUILDING AND ON THE OPPOSITE SIDE. PERHAPS WHERE | | | THE STORAGE ROOM IS LOCATED IS MORE APT FOR SHOWER | | | FACILITIES. | | | | | | 19. SHEET A3.01 PARKING STALL DIMENSIONS NOT COMPLIANT | | | WITH CITY STANDARD AND STRIPPING DETAIL. STANDARD | | | SPACES SHOULD BE 8.5FTX18FT AND ADA SPACES ARE | | | 12FTX18FT WITH 5 ADA AISLE, COMPACT SPACES ARE | | | TYPICALLY 8FTX16FT. PLEASE NOTE, ONLY 30% OF PARKING | | | SPACES MAY BE DESIGNATED AS COMPACT SPACES AND SHALL BE | | | INDICATED COMPACT SPACES WILL REQUIRE SEPARATE SIGNAGE | | | DESIGNATING THESE SPACES AS COMPACT. | | | | | | RESPONSE: PARKING STALL DIMENSIONS AND STRIPING DETAILS | | | AS SHOWN ON SHEET A3.01 ARE CONSISTENT WITH THE | | | REQUIREMENTS OF SECTION 94-485 OF THE WEST PALM BEACH | | | ZONING CODE, INCLUDING FIGURE XV-2 AND THE STALL | | | PAINTING DETAIL. WE HAVE SPLIT THE STANDARD SPACE AND | | | ACCESSIBLE SPACE DETAILS INTO TWO SEPARATE DETAILS FOR | | | FURTHER CLARITY. | | | | | | 21% OF PARKING SPACES SHOWN ARE INDICATED AS COMPACT | | | SPACES AND WILL BE SIGNED TO SO INDICATE. PLEASE SEE | | | SHEETS A1.02 THROUGH A1.07. | | | | | | ZONING REVIEW 12/2/22 ??? [SATISFIED] | | | | | | 20. SHEET A1.06 & A1.07 SHOWS WHAT APPEARS TO BE TANDEM | | | SPACES, PLEASE NOTE PER SEC. 94-111 (E.): FOR | | | COMMERCIAL USES, TANDEM PARKING SPACES SHALL BE COUNTED | | | AS ONE SPACE UNLESS THERE IS A VALET ATTENDANT IN | | | CHARGE OF ALL OPERATING HOURS, AND SUCH REQUIREMENT IS | | | ESTABLISHED THROUGH A RESTRICTIVE COVENANT. ALL | | | RESTRICTIVE COVENANTS AND OTHER DOCUMENTS REQUIRED TO | | | BE RECORDED SHALL BE ON CITY APPROVED FORMS, AND | | | RECORDED IN PUBLIC RECORDS. | | | | | | RESPONSE: ACKNOWLEDGED. ALL TANDEM SPACES WILL BE | | | SERVED BY A VALET ATTENDANT DURING OPERATING HOURS. THE | | | PROPERTY OWNER WILL EXECUTE A RESTRICTIVE COVENANT, AS | | | REQUIRED. | | | ZONING REVIEW 12/2/22 ??? [SATISFIED] CONDITION OF SITE | | | PLAN APPROVAL. | | | | | | ADDITIONALLY DUE TO THE INCLUSION OF STACKERS, PER SEC. | | | 94-111(K.): MECHANICAL AND AUTOMATED PARKING. PARKING | | | STRUCTURES WITH MECHANICAL PARKING SHALL PROVIDE A | | | COMMERCIAL ATTENDANT DURING THE OPERATIONS HOURS, AND | | | SUCH OPERATION IS ESTABLISHED THROUGH A RESTRICTIVE | | | COVENANT RECORDED IN THE PUBLIC RECORDS. ALL | | | RESTRICTIVE COVENANTS AND OTHER DOCUMENTS REQUIRED TO | | | BE RECORDED SHALL BE ON CITY APPROVED FORMS, AND | | | RECORDED IN THE PUBLIC RECORDS. | | | | | | RESPONSE: ACKNOWLEDGED. ALL STACKER SPACES WILL BE | | | SERVED BY A VALET ATTENDANT DURING OPERATING HOURS. THE | | | PROPERTY OWNER WILL EXECUTE A RESTRICTIVE COVENANT, AS | | | REQUIRED. | | | ZONING REVIEW 12/2/22 ??? [SATISFIED] CONDITION OF SITE | | | PLAN APPROVAL. | | | | | | A VALET OR OPERATION ATTENDANT WILL BE REQUIRED FOR | | | STACKERS, AS SUCH THE TANDEM SPACE IF SERVICED BY THE | | | VALET OPERATIONS MAY COUNT AS 2 SPACES. PLEASE PROVIDE | | | DETAILS OF THE STACKERS. | | | | | | RESPONSE: PLEASE SEE DETAILS 7 & 9 / SHEET A3.01 FOR | | | THE STACKER DETAIL. | | | ZONING REVIEW 12/2/22 ??? [SATISFIED] | | | | | | 21. PLEASE CLARIFY MIDDLE OF PARKING STRUCTURE ON SHEET | | | A1.05, ELECTRIC SPACES APPEAR TO OVERLAP COMPACT | | | SPACES, AND CONFLICT WITH THE PARKING RAMP. | | | | | | RESPONSE: THE AREA IN QUESTION ON SHEET A1.05 IS | | | SHOWING LEVEL 4.5, BELOW, AND THUS SPACES APPEAR TO BE | | | OVERLAPPING. WE HAVE MORE CLEARLY INDICATED A GUARD | | | WALL AT THE EDGE OF SLAB OF LEVEL 5 ON A1.05, REVISED. | | | | | | ZONING REVIEW 12/2/22 ??? [SATISFIED] | | | | | | 22. SHEET A1.01 SHOWS A CANOPY ON THE FERN ST. SIDE, | | | PLEASE PROVIDE DETAILS THAT THE CANOPY IS IN COMPLIANCE | | | WITH THE PROJECTION STANDARDS OF SEC. 94-109 TABLE | | | IV-5. REQUIRES 10FT. VERTICAL CLEARANCE, MAXIMUM | | | ENCROACHMENT IN ROW OF 12FT AND MAXIMUM PROJECTION OF | | | 20FT. | | | | | | RESPONSE: PLEASE SEE DETAILS 4 AND 5 ON SHEET A0.06E, | | | WITH ADDITIONAL DIMENSIONAL INFORMATION. | | | | | | ZONING REVIEW 12/2/22 ??? [SATISFIED] | | | | | | | | | ZONING REVIEW 12/12/22 ??? NEW COMMENTS/VARIANCE LIST: | | | | | | 1. ALONG FERN ST. FRONTAGE, STREET TREES NEED TO BE | | | LOCATED ADJACENT TO THE CURB, MOVE TREES INTO PROPOSED | | | LANDSCAPE BEDS ON EITHER SIDE OF THE PROPOSED DROP-OFF | | | SPACE. IF REQUIREMENT CANNOT BE ACCOMODATED MAY BE | | | SUBJECT TO VARIANCE. | | | | | | 2. ALONG FERN ST. FRONTAGE, STREET TREES NEED TO MEET | | | THE 30 FT. ON CENTER MEASUREMENT, PALMS DO NOT COUNT | | | TOWARD TREE COUNT, NEED AT LEAST 10 ON FERN FRONTAGE. | | | THE TREES WITHIN TREEGRATES ADJACENT TO THE DROP-OFF | | | MUST MEET 30 FT. SPACING TOO. IF REQUIREMENT CANNOT BE | | | ACCOMODATED MAY BE SUBJECT TO VARIANCE. | | | | | | VARIANCES: | | | 1. CONDITIONAL SETBACK OF 27??? FROM BACK OF CURB ALONG | | | EVERNIA FOR LEVELS 5+ OF PARKING. REQUESTING A 12??? | | | REDUCTION ON LEVEL 6 & LEVEL 7. | | | 2. VARIANCE FROM SECTION 94-132(E.)(3.)(C.) TO COUNT | | | THE PORTION OF THE SETBACK/LAND DEDICATION AREA WITHIN | | | BUILDING REQUIREMENTS. | | | 3. VARIANCE FROM PARKING REQUIREMENTS (TABLE IV-9) FOR | | | OFFICE USES. DEFICIENT 180 SPACES FOR OFFICE USE. MIN. | | | REQ. 946 PROVIDING 766. (19% REDUCTION) | | | | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
10-13-2022 |
|
|
Cont ID |
|
| Sent By |
ckimmerl |
Date |
10-13-2022 |
Time |
10:46 |
Rev Time |
0.00 |
| Received By |
ckimmerl |
Date |
10-13-2022 |
Time |
10:42 |
Sent To |
|
|
| Notes |
| 2022-10-13 10:44:39 | 1. VARIANCE REQUEST FOR BUILDING FOOTPRINT LEVEL 6-7 | | | (MAX. 60%) PROPOSED 63%. PER SECTION 95-54(D.)(4.) | | | UNAUTHORIZED VARIANCES. THE DAC IS NOT AUTHORIZED TO | | | GRANT VARIANCES FOR ANY OF THE FOLLOWING: (E.) AN | | | INCREASE IN MAXIMUM BUILDING FOOTPRINT ABOVE THE | | | MAXIMUM FOOTPRINT ALLOWED BY THE URBAN REGULATIONS. | | | | | | 2. WHAT IS THE TOTAL SQUARE FOOTAGE FOR OFFICE SPACE | | | AND RETAIL? JUSTIFICATION LETTER STATES OFFICE AT | | | 425,798 SF; SHEET A0.01 STATES 378,137 SF; PLEASE | | | CLARIFY SO STAFF MAY VERIFY PARKING REQUIREMENTS. | | | RETAIL IN JUSTIFICATION LETTER IS 9,369 SF; SHEET A0.01 | | | STATES 9,161 SF. PARKING COUNT WILL HAVE TO BE ADJUSTED | | | TO MEET RESPECTIVE REQUIREMENTS, THE RATIOS PER USE | | | PROVIDED ON A0.01 ARE CORRECT. | | | | | | 3. PLEASE PROVIDE DIMENSIONS OR CALLOUTS SPECIFYING | | | DEPTH OF ALL SETBACKS ON SITE PLANS, FLOOR PLANS, AND | | | ELEVATIONS. MINIMUM AND MAXIMUM SETBACKS SHOWN. | | | A. CONDITIONAL SETBACK FOR PARKING USES ABOVE THE 5TH | | | FLOOR; SHEET A1.06 ONLY SHOWS EVERNIA STREET SETBACK | | | (PLEASE LABEL REQUIRED 27??? FROM BACK OF CURB) | | | B. REQUIRED CONDITIONAL SETBACK ALONG FERN AND | | | QUADRILLE PLAZA DR. IS 31??? (PLEASE LABEL ON SHEET | | | A1.06 AND A1.07) | | | C. PLEASE LABEL OR PROVIDE THE FEC ROW ABUTMENT | | | SETBACKS AND CONDITIONAL SETBACKS ON SHEET A0.05 AND | | | A1.01 ONWARD. | | | | | | 4. SHEET A0.08 FAR | | | A. LEVEL 1 FAR ??? FAR COUNT NEEDS TO INCLUDE STORAGE | | | SPACE ADJACENT TO PARKING RAMP | | | B. LEVEL 2 FAR ??? PORTION OF NORTHEAST STAIRWELL NOT | | | SHOWN AS IT IS ON A1.02, PORTION NEEDS TO BE COUNTED IN | | | FAR | | | C. MINOR NOTE: SHEET A1.03 DOESN???T SHOW SOUTHERN | | | ELEVATOR AS YELLOW SHADING FOR CIRCULATION | | | D. LEVEL 4 FAR ??? PORTION OF NORTHWEST STAIRWELL NOT | | | SHOWN AS IT IS ON A1.04, PORTION NEEDS TO BE COUNTED IN | | | FAR | | | E. PENTHOUSE FAR ??? ROOFTOP ON A1.26 SHOWS UNLABELED | | | ROOM BELOW THE ELEVATOR OVERRUNS, PLEASE LABEL AND IF | | | NOT MECHANICAL, SPACE WILL COUNT TOWARD FAR. | | | | | | 5. PUBLIC OPEN SPACE REQUIREMENT NEEDS TO BE ADJUSTED. | | | 3% REQUIREMENT FOR LOTS 50,000-80,000SF; TOTAL REQUIRED | | | 2,292 SF. PLUS THE ADDITIONAL 3,501 SF FROM THE ALLEY | | | ABANDONMENT 1:1 REPLACEMENT. TOTAL REQUIRED 5,793 SF. | | | PLEASE ADJUST TABLE ON SHEET A0.06 OR LP-1 TO REFLECT | | | CORRECT NUMBERS. | | | | | | 6. WILL THE QUADRILLE PLAZA DRIVE RIGHT-OF-WAY BE A | | | DEDICATED ROW? WHAT IS THE FINAL ROW WIDTH? PLEASE | | | INDICATE ROW LINE ON PLANS, AS THIS IMPACTS SETBACKS | | | AND SITE CONFIGURATION. PLEASE PROVIDE DETAILED | | | DIMENSIONS AND CONDITIONS OF THE QUADRILLE PLAZA DR. | | | EXTENSION (SIDEWALK, TRAVEL LANE, LANDSCAPE BUFFERS, | | | PLANTERS/LANDSCAPE BEDS, ETC.) ON SITE AND GROUND FLOOR | | | PLANS, AS IS SHOWN IN CIVIL PLANS. | | | | | | 7. REMOVAL OF METERED ON-STREET PARKING WILL INCUR A | | | REMOVAL FEE. PERMANENT REMOVAL FEE INCLUDED WITHIN | | | RESOLUTION 191-22, $24,000 PER SPACE. PLEASE SPEAK WITH | | | ED DAVIS ??? PARKING ADMINISTRATOR FOR ANY QUESTIONS | | | REGARDING THE REMOVAL PROCESS OR FEES. | | | | | | 8. PLEASE NOTE; IN THOSE CASES WHERE THE SIDE OF ANY | | | PARKING STALL IS ADJACENT TO A WALL, FENCE, BUILDING, | | | OR OTHER PHYSICAL OBSTRUCTION, THE STALL WIDTHS SHALL | | | BE INCREASED BY A MINIMUM OF ONE FOOT. WHERE THERE IS | | | AN OBSTRUCTION ON BOTH SIDES OF THE STALL, THE STALL | | | WIDTHS SHALL BE INCREASED BY A MINIMUM OF TWO FEET. | | | | | | 9. HISTORIC PRESERVATION ??? THE 501 FERN ST. BUILDING | | | IS HISTORICALLY ELIGIBLE, PER THE REQUIREMENT OF SEC. | | | 94-131 THE BUILDING SHALL BE INTEGRATED INTO THE | | | PROJECT AS PART OF THE NEW DEVELOPMENT. IF THE NEW | | | QUADRILLE PLAZA DR. ROW DOES NOT CONSUME THIS BUILDING, | | | BOTH HISTORIC PRESERVATION AND PLANNING STAFF REQUEST | | | THAT THE DESIGN ELEMENTS FROM THE FRONT FA??ADE OF THE | | | 501 BUILDING BE PRESERVED, REPLICATED, OR INTEGRATED | | | INTO THE GROUND-FLOOR DESIGN OF THE PROPOSED 515 | | | BUILDING AT THIS CORNER. PARTICULARLY THE FLUTED | | | COLUMN-LIKE ELEMENTS AND THE HORIZONTAL STRIATIONS OF | | | THE CORNICE AND ENTRY CANOPY. | | | | | | 10. PLEASE LABEL AND PROVIDE SIDEWALK DIMENSIONS, AS | | | WELL AS DIMENSIONS FOR PLANTERS/LANDSCAPE AREAS OR | | | ELEMENTS WITHIN THE ROW ON BOTH THE GROUND FLOOR AND | | | SITE PLAN A0.05 AND A1.01; APPEARS TO BE 8-12??? CLEAR, | | | STAFF WOULD LIKE TO VERIFY THAT THE 8??? CLEAR PATH IS | | | MAINTAINED. CIVIL PLANS PROVIDE THESE DIMENSIONS. | | | | | | 11. SHEET A0.06D FOR THE FA??ADE ARTICULATION | | | COMPLIANCE MATRIX: WEST, ON THE PROVIDED FENESTRATION | | | IT IS NOTED THAT FA??ADE E, & G ARE MORE THAN 3 FT FROM | | | THE LOT LINE; SHOULD THIS READ AS LESS THAN 3 FT? | | | | | | 12. DUE TO THE SIGNIFICANCE IN SCALE FOR THE PROPOSED | | | DEVELOPMENT PROJECT AND ITS IMPACT ON THE SURROUNDING | | | ROADWAY NETWORK, STAFF REQUESTS THAT TDM STRATEGIES ARE | | | DISCUSSED FOR THIS PROJECT. | | | | | | 13. ON SHEET A0.06E, PLEASE PROVIDE PROJECTION | | | DIMENSION ON THE HORIZONTAL FEATURES. | | | | | | 14. QUADRILLE PLAZA DR. EXTENSION SHOULD BE RIGHT-TURN | | | ONLY AT FERN ST. INTERSECTION, NOT ENOUGH QUEUING OR | | | STACKING SPACE BEFORE THE TRAIN TRACKS. | | | | | | 15. PLEASE ILLUSTRATE SITE VISIBILITY TRIANGLES SO THAT | | | STAFF MAY VERIFY THAT THERE ARE NO OBSTRUCTIONS AT THE | | | INTERSECTIONS AND DRIVES. | | | | | | 16. MINOR NOTE: DRAWINGS ONLY PROVIDE ENTRY TO BIKE | | | ROOM FROM OUTSIDE PLAZA, IS THIS INTENTIONAL? | | | | | | 17. PLEASE PROVIDE A DETAILED AND DIMENSIONED SCHEMATIC | | | FOR THE INTERNAL BIKE ROOM, SHOWING THE PROPOSED RACKS | | | FROM A3.01 WITH ADEQUATE SPACING/SEPARATION WITHIN THE | | | ROOM. PLEASE PROVIDE THE SPACING DETAILS FOR THE | | | OUTSIDE BIKE RACKS AS WELL. | | | | | | 18. PER SEC. 94-111; A MINIMUM OF ONE SHOWER AND | | | CHANGING FACILITY SHALL BE PROVIDED TO BE AVAILABLE FOR | | | ALL TENANTS AND SHALL BE LOCATED WITHIN THE BUILDING, | | | OR WITHIN 200 FEET OF THE BUILDING ENTRANCE, FOR | | | DEVELOPMENTS GREATER THAN 50,000 SQUARE FEET IN GROSS | | | BUILDING AREA. | | | PLEASE INDICATE ON THE PLANS WHERE THIS SHOWER FACILITY | | | IS LOCATED. | | | | | | 19. SHEET A3.01 PARKING STALL DIMENSIONS NOT COMPLIANT | | | WITH CITY STANDARD AND STRIPING DETAIL. STANDARD SPACES | | | SHOULD BE 8.5???X18??? AND ADA SPACES ARE 12X???18??? | | | WITH 5??? ADA AISLE. COMPACT SPACES ARE TYPICALLY | | | 8???X16???. PLEASE NOTE, ONLY 30% OF PARKING SPACES MAY | | | BE DESIGNATED AS COMPACT SPACES AND SHALL BE INDICATED | | | AS SUCH ON PLANS. PLEASE PROVIDE TOTAL CALCULATION. | | | COMPACT SPACES WILL REQUIRE SEPARATE SIGNAGE | | | DESIGNATING THESE SPACES AS COMPACT. | | | | | | 20. SHEET A1.06 & A1.07 SHOWS WHAT APPEARS TO BE TANDEM | | | SPACES, PLEASE NOTE PER SEC. 94-111 (E.): FOR | | | COMMERCIAL USES, TANDEM PARKING SPACES SHALL BE COUNTED | | | AS ONE SPACE UNLESS THERE IS A VALET ATTENDANT IN | | | CHARGE OF THE OPERATION OF THE PARKING FACILITY DURING | | | ALL OPERATING HOURS, AND SUCH REQUIREMENT IS | | | ESTABLISHED THROUGH A RESTRICTIVE COVENANT. ALL | | | RESTRICTIVE COVENANTS AND OTHER DOCUMENTS REQUIRED TO | | | BE RECORDED SHALL BE ON CITY APPROVED FORMS, AND | | | RECORDED IN THE PUBLIC RECORDS. | | | | | | ADDITIONALLY DUE TO THE INCLUSION OF STACKERS, PER SEC. | | | 94-111 (K.): MECHANICAL AND AUTOMATED PARKING. PARKING | | | STRUCTURES WITH MECHANICAL PARKING SHALL PROVIDE A | | | COMMERCIAL ATTENDANT DURING THE OPERATING HOURS OF THE | | | FACILITY. SUCH OPERATION SHALL BE ENFORCED THROUGH A | | | RESTRICTIVE COVENANT RECORDED IN THE PUBLIC RECORDS. | | | ALL RESTRICTIVE COVENANTS AND OTHER DOCUMENTS REQUIRED | | | TO BE RECORDED SHALL BE ON CITY APPROVED FORMS, AND | | | RECORDED IN THE PUBLIC RECORDS. | | | | | | A VALET OR OPERATION ATTENDANT WILL BE REQUIRED FOR | | | STACKERS, AS SUCH THE TANDEM SPACES IF SERVICED BY THE | | | VALET OPERATIONS MAY COUNT AS 2 SPACES. PLEASE PROVIDE | | | DETAILS OF THE STACKERS. | | | | | | 21. PLEASE CLARIFY MIDDLE OF PARKING STRUCTURE ON SHEET | | | A1.05, ELECTRIC SPACES APPEAR TO OVERLAP COMPACT | | | SPACES, AND CONFLICT WITH THE PARKING RAMP. | | | | | | 22. SHEET A1.01 SHOWS A CANOPY ON THE FERN ST. SIDE, | | | PLEASE PROVIDE DETAILS THAT THE CANOPY IS IN COMPLIANCE | | | WITH THE PROJECTION STANDARDS OF SEC. 94-109 TABLE | | | IV-5. REQUIRES 10FT. VERTICAL CLEARANCE, MAXIMUM | | | ENCROACHMENT IN ROW OF 12FT. AND MAXIMUM PROJECTION OF | | | 20FT. | | | | | | CHRIS KIMMERLY, AICP | | | URBAN DESIGN PLANNER | | | [email protected] 822-1426 | | | |
|
|
| |