Plan Review Details - Project Z22090007
Plan Review Stops For Project Z22090007
Review Stop AIPP ART IN PUBLIC PLACES
Rev No 1 Status N Date 10-11-2022 Cont ID  
Sent By swelter Date 10-11-2022 Time 14:05 Rev Time 0.00
Received By swelter Date   Time   Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time 0.00
Received By   Date   Time   Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 01-13-2023 Cont ID  
Sent By rbrown Date 01-13-2023 Time 19:17 Rev Time 0.00
Received By rbrown Date 01-13-2023 Time 19:17 Sent To  
Notes
2023-01-13 19:32:22DEVELOPMENT SERVICES DEPARTMENT, BUILDING DIVISION,
 COMMENTS:
  
 1. THIS REVIEW IS A CURSORY REVIEW AS IT RELATES TO THE
 SITE. IT IS NOT A REVIEW FOR FULL COMPLIANCE WITH
 FLORIDA BUILDING CODE. THE FOLLOWING COMMENTS ARE TO BE
 ADDRESSED FOR THE BUILDING PERMIT APPLICATION.
  
 2. DEMOLITION OF THE EXISTING BUILDING. AN ASBESTOS
 SURVEY SHALL BE PERFORMED AND AN ASBESTOS ABATEMENT
 REPORT SUBMITTED TO THE HEALTH DEPARTMENT PALM BEACH
 COUNTY OFFICE. CONTACT ALEX ORTEGA AT (561) 837-5963,
 OR BY EMAIL: [email protected]
  
 3. FLOOD ZONE. THE SUBMITTED RESPONSE IS NOTED, HOWEVER
 THE CITY OF WEST PALM BEACH CODE OF ORDINANCES REQUIRES
 THAT ALL BUILDINGS AND ASSOCIATED EQUIPMENT HAVE A 24
 INCH FREEBOARD SO THAT THE CITY CAN MAINTAIN ITS
 COMMUNITY RATING SYSTEM (CRS) RATING WHICH GIVES WEST
 PALM BEACH PROPERTY OWNERS FLOOD INSURANCE DISCOUNTS
 THAT EXCEED MANY JURISDICTIONS. IF THE CITY DOES NOT
 ENFORCE THE PROVISION OF THE ORDINANCE AN AUDT BY FEMA
 WOULD RESULT IN INCREASED FLOOD INSURANCE RATES FOR ALL
 WEST PALM BEACH PROPERTY OWNERS. WE WILL NOT ALLOW THAT
 TO HAPPEN BECAUSE OF ANY ONE PROJECT. YOUR RESPONSE IS
 NOT CORRECT AND CANNOT BE THE FINAL RECORD. ACCORDING
 TO THE ADOPTED FLOOD INSURANCE RATE MAPS (FIRMS), THE
 PROPOSED BUILDING IS IN FLOOD ZONE AE, WITH A BASE
 FLOOD ELEVATION OF 13.4 FT NAVD. THE FIRST FLOOR OF THE
 BUILDING AND ALL ASSOCIATED MECHANICAL EQUIPMENT
 (CHILLERS, GENERATORS ETC.) SHALL BE 24 INCHES
 (FREEBOARD) ABOVE THE BASE FLOOD ELEVATION.
  
 4. BUILDING SIZE. WHEN SUBMITTED FOR BUILDING PERMIT,
 THE PLANS SHALL SHOW THAT THE TYPE OF CONSTRUCTION FOR
 THE BUILDINGS WILL BE IN ACCORDANCE WITH THE HEIGHT,
 AREA AND OCCUPANCY LIMITATIONS IN CHAPTER 5 OF THE
 FLORIDA BUILDING CODE.
  
 5. BUILDING LOCATION RELATIVE TO THE PROPERTY LINE AND
 OTHER STRUCTURES. WHEN SUBMITTED FOR BUILDING PERMIT,
 COMPLIANCE WITH ALL BUILDING SEPARATION, PERCENTAGE OF
 OPENINGS AND OPENING PROTECTIVE REQUIREMENTS OF
 CHAPTERS 6 AND 7 OF THE FLORIDA BUILDING CODE SHALL BE
 VERIFIED.
  
 6. GREASE/PETROLEUM INTERCEPTOR. A GREASE/PETROLEUM
 INTERCEPTOR WILL BE REQUIRED. FOR INFORMATION ON THE
 REQUIRED TYPE, SIZE AND LOCATION, PLEASE CONTACT RYAN
 BROWN, CHIEF PLUMBING INSPECTOR, DEVELOPMENT SERVICES
 DEPARTMENT, AT (561) 805-6692, OR BY EMAIL:
 [email protected]
  
 7. SEPARATE PERMITS REQUIRED. ALL APPLICABLE PERMITS
 AND SUB-PERMITS MUST BE OBTAINED BEFORE COMMENCING THE
 WORK. SEPARATE PERMITS, PLANS AND FEES, ARE REQUIRED
 FOR SIGNS, GAS SYSTEMS, GENERATORS, FIRE ALARM SYSTEMS,
 FIRE SPRINKLER AND OTHER FIRE SUPPRESSION SYSTEMS,
 GREASE INTERCEPTORS, SITE LIGHTING, SITE LANDSCAPE,
 SITE IRRIGATION, ETC.
  
 8. BUILDING ADDRESS. EACH SEPARATE BUILDING, AND UNIT
 WITH AN INDEPENDENT ENTRANCE FROM THE STREET, SHALL
 HAVE A SEPARATE ADDRESS ASSIGNED BASED ON THE LOCATION
 OF THE BUILDING ENTRANCE. FOR STREET ADDRESSING,
 CONTACT CAROLINE PUELL, ADDRESSING COORDINATOR, AT
 (561) 805 6659, OR BY EMAIL: [email protected]
  
 9. ART IN PUBLIC PLACES. THIS PROJECT WILL BE SUBJECT
 TO ART LIFE ASSESSMENT UNDER THE CITY OF WEST PALM
 BEACH ART IN PUBLIC PLACES (AIPP) PROGRAM. FOR ADVICE
 ON THE PROVISION OF PUBLIC ARTWORK IN LIEU OF THE AIPP
 ASSESSMENT, CONTACT SYBILLE WELTER, ART IN PUBLIC
 PLACES COORDINATOR, AT (561) 822-1521, OR BY EMAIL:
 [email protected]
  
 ROBERT BROWN
 BUILDING OFFICIAL
 TEL: 561 805 6652
 EMAIL: [email protected]
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 10-12-2022 Cont ID  
Sent By rbrown Date 10-12-2022 Time 22:01 Rev Time 0.00
Received By rbrown Date 10-12-2022 Time 22:01 Sent To  
Notes
2022-10-12 22:13:46DEVELOPMENT SERVICES DEPARTMENT, BUILDING DIVISION,
 COMMENTS:
  
 1. THIS REVIEW IS A CURSORY REVIEW AS IT RELATES TO THE
 SITE. IT IS NOT A REVIEW FOR FULL COMPLIANCE WITH
 FLORIDA BUILDING CODE. THE FOLLOWING COMMENTS ARE TO BE
 ADDRESSED FOR THE BUILDING PERMIT APPLICATION.
  
 2. DEMOLITION OF THE EXISTING BUILDING. AN ASBESTOS
 SURVEY SHALL BE PERFORMED AND AN ASBESTOS ABATEMENT
 REPORT SUBMITTED TO THE HEALTH DEPARTMENT PALM BEACH
 COUNTY OFFICE. CONTACT ALEX ORTEGA AT (561) 837-5963,
 OR BY EMAIL: [email protected]
  
 3. FLOOD ZONE. ACCORDING TO THE ADOPTED FLOOD INSURANCE
 RATE MAPS (FIRMS), THE PROPOSED BUILDING IS IN FLOOD
 ZONE AE, WITH A BASE FLOOD ELEVATION OF 13.4 FT NAVD.
 THE FIRST FLOOR OF THE BUILDING AND ALL ASSOCIATED
 MECHANICAL EQUIPMENT (CHILLERS, GENERATORS ETC.) SHALL
 BE 24 INCHES (FREEBOARD) ABOVE THE BASE FLOOD
 ELEVATION.
  
 4. NUMBER OF ACCESSIBLE PARKING SPACES. SITE PLAN,
 SHEET C-02, DOES NOT STATE HOW MANY CUSTOMER PARKING
 SPACES WILL BE PROVIDED. IT SHOWS MORE THAN 100
 CUSTOMER PARKING SPACES BUT SHOWS ONLY 4 ACCESSIBLE
 PARKING SPACES. THE MINIMUM NUMBER OF ACCESSIBLE
 PARKING SPACES PROVIDED SHALL BE IN ACCORDANCE WITH
 SECTION 208.2 OF FLORIDA ACCESSIBILITY CODE.
  
 5. LOCATION OF ACCESSIBLE PARKING SPACES. SITE PLAN,
 SHEET C-02, DOES NOT SHOW ANY ACCESSIBLE PARKING SPACES
 NEAR THE PARTS AND SERVICE BUILDING. PER SECTION 208.3
 OF FLORIDA ACCESSIBILITY CODE, ACCESSIBLE PARKING
 SPACES ARE TO BE LOCATED ON THE SHORTEST POSSIBLE ROUTE
 OF TRAVEL FROM ADJACENT PARKING TO AN ACCESSIBLE
 ENTRANCE. THE DESIGN OF ACCESSIBLE PARKING SPACES SHALL
 COMPLY WITH SECTION 502 OF FLORIDA ACCESSIBILITY CODE
  
 6. ELECTRIC VEHICLE CHARGING STATION. IF ELECTRIC
 VEHICLE (EV) CHARGING STATIONS ARE PROVIDED AT LEAST 1
 IN 25 MUST COMPLY WITH ACCESSIBLE PARKING SPACE
 REQUIREMENTS.
  
 7. BUILDING SIZE. WHEN SUBMITTED FOR BUILDING PERMIT,
 THE PLANS SHALL SHOW THAT THE TYPE OF CONSTRUCTION FOR
 THE BUILDINGS WILL BE IN ACCORDANCE WITH THE HEIGHT,
 AREA AND OCCUPANCY LIMITATIONS IN CHAPTER 5 OF THE
 FLORIDA BUILDING CODE.
  
 8. BUILDING LOCATION RELATIVE TO THE PROPERTY LINE AND
 OTHER STRUCTURES. WHEN SUBMITTED FOR BUILDING PERMIT,
 COMPLIANCE WITH ALL BUILDING SEPARATION, PERCENTAGE OF
 OPENINGS AND OPENING PROTECTIVE REQUIREMENTS OF
 CHAPTERS 6 AND 7 OF THE FLORIDA BUILDING CODE SHALL BE
 VERIFIED.
  
 9. GREASE/PETROLEUM INTERCEPTOR. A GREASE/PETROLEUM
 INTERCEPTOR WILL BE REQUIRED. FOR INFORMATION ON THE
 REQUIRED TYPE, SIZE AND LOCATION, PLEASE CONTACT RYAN
 BROWN, CHIEF PLUMBING INSPECTOR, DEVELOPMENT SERVICES
 DEPARTMENT, AT (561) 805-6692, OR BY EMAIL:
 [email protected]
  
 10. SEPARATE PERMITS REQUIRED. ALL APPLICABLE PERMITS
 AND SUB-PERMITS MUST BE OBTAINED BEFORE COMMENCING THE
 WORK. SEPARATE PERMITS, PLANS AND FEES, ARE REQUIRED
 FOR SIGNS, GAS SYSTEMS, GENERATORS, FIRE ALARM SYSTEMS,
 FIRE SPRINKLER AND OTHER FIRE SUPPRESSION SYSTEMS,
 GREASE INTERCEPTORS, SITE LIGHTING, SITE LANDSCAPE,
 SITE IRRIGATION, ETC.
  
 11. BUILDING ADDRESS. EACH SEPARATE BUILDING, AND UNIT
 WITH AN INDEPENDENT ENTRANCE FROM THE STREET, SHALL
 HAVE A SEPARATE ADDRESS ASSIGNED BASED ON THE LOCATION
 OF THE BUILDING ENTRANCE. FOR STREET ADDRESSING,
 CONTACT CAROLINE PUELL, ADDRESSING COORDINATOR, AT
 (561) 805 6659, OR BY EMAIL: [email protected]
  
 12. ART IN PUBLIC PLACES. THIS PROJECT WILL BE SUBJECT
 TO ART LIFE ASSESSMENT UNDER THE CITY OF WEST PALM
 BEACH ART IN PUBLIC PLACES (AIPP) PROGRAM. FOR ADVICE
 ON THE PROVISION OF PUBLIC ARTWORK IN LIEU OF THE AIPP
 ASSESSMENT, CONTACT SYBILLE WELTER, ART IN PUBLIC
 PLACES COORDINATOR, AT (561) 822-1521, OR BY EMAIL:
 [email protected]
  
 ROBERT BROWN
 BUILDING OFFICIAL
 TEL: 561 805 6652
 EMAIL: [email protected]
  

Review Stop ENG - PPRC ENGINEERING - PPRC
Rev No 2 Status P Date 02-28-2023 Cont ID  
Sent By rrossano Date 02-28-2023 Time   Rev Time 0.00
Received By rrossano Date 02-28-2023 Time   Sent To  
Notes
***NONE***

Review Stop ENG - PPRC ENGINEERING - PPRC
Rev No 1 Status F Date 09-26-2022 Cont ID  
Sent By rrossano Date 09-26-2022 Time   Rev Time  
Received By rrossano Date 09-26-2022 Time   Sent To  
Notes
2022-09-26 13:59:03COMMENTS FROM RICK ROSSANO, SR. PROJECT COORDINATOR,
 ENGINEERING SERVICES AT 561-494-1098 [email protected]
 GENERAL:
 O PLEASE RESPOND TO ALL COMMENTS IN WRITING, AND
 INCLUDE PROJECT NAME, ADDRESS AND PERMIT NUMBER
 (Z-XXXXXXXX).
 O THE CITY OF WEST PALM BEACH HAS A NUMBER OF
 REGULATIONS AND PERMIT REQUIREMENTS WHICH DIRECTLY
 AFFECT THE DEVELOPMENT AND INSTALLATION OF WATER AND
 WASTEWATER UTILITIES WITHIN THE CITY. PLEASE SEE
 DEVELOPMENT PERMIT SUBMITTAL REQUIREMENTS AT THE LINK
 BELOW:
 A. HTTP://WPB.ORG/CMSPAGES/GETAMAZONFILE.ASPX?PATH=~\WP
 B_WEBSITE\MEDIA\ENGINEERING\DEVELOPMENT-APPLICATION-FUL
 L-PACKAGE_2016.PDF&HASH=7BD4DD7EB6115181D8C5977BCC02A97
 B1960045731D3658206F27451722716EF
 B. THIS AND OTHER RELATED ENGINEERING DOCUMENTS CAN BE
 FOUND HERE:
 HTTP://WPB.ORG/DEPARTMENTS/ENGINEERING-PUBLIC-WORKS/FOR
 MS,-PERMITS-APPLICATIONS
 C. ALSO SEE: CODE OF ORDINANCES, CITY OF WEST PALM
 BEACH, FLORIDA, CODIFIED THROUGH ORD. NO. 4183-08,
 ADOPTED SEPT. 22, 2008. (SUPPLEMENT NO. 18)
 CHAPTER 90 UTILITIES, ARTICLE I. IN GENERAL,
 SEC. 90-7. POLICY REGARDING EXTENSION OF WATER OR SEWER
 SERVICE FACILITIES OF THE CITY.
 THE WATER AND WASTEWATER SERVICE AGREEMENTS AND THE
 CONSTRUCTION PERMITS ADDRESS RESERVATION OF CAPACITY
 BASED ON USAGE, METER SIZE AND FEES, DESIGN STANDARDS,
 BACKFLOW PREVENTION, FIRE SERVICE AND IRRIGATION.
 O AS OF DECEMBER 20, 2015, THE CITY OF WEST PALM BEACH
 CROSS-CONNECTION CONTROL MANUAL HAS BEEN REVISED,
 STATING "ALL BACKFLOW DEVICES MUST BE LEAD-FREE". FOR
 MORE INFORMATION, REFER TO THE LINK BELOW:
 A. HTTP://WPB.ORG/DEPARTMENTS/PUBLIC-UTILITIES/FORMS-PU
 BLICATIONS/BACKFLOW-CROSS-CONNECTION- CONTROL-MANUAL
 O PLEASE SUBMIT A FORMAL AS-BUILT REQUEST FOR ALL CITY
 OF WEST PALM BEACH-OWNED UTILITIES WITHIN THE PUBLIC
 RIGHT OF WAY FOR THE ENTIRE EXTENT OF THE LIMITS OF
 YOUR PROJECT. IDENTIFY TYPE OF UTILITY, LOCATION, PIPE
 MATERIAL, AGE AND SIZE. PLEASE CONTACT JANICE TARBILL
 IN THE WPB ENGINEERING SERVICES DEPARTMENT AT
 [email protected] OR 561-494-1079 FOR FURTHER
 ASSISTANCE. NOTE THAT FIELD RECORDS ARE FOR INFORMATION
 ONLY. FIELD VERIFY UTILITY LOCATIONS USING FIELD
 SURVEY, POT-HOLING, SOFT DIGS ETC.
 O PROVIDE EXISTING AND PROPOSED PERVIOUS AND IMPERVIOUS
 DATA.
  
 BACKFLOW ASSEMBLY AND METERS:
 O SHOW AND LABEL ANY EXISTING OR PROPOSED WATER
 SERVICES AND WATER METERS, ALONG WITH WHAT IS HAPPENING
 TO THEM.
 O SHOW EXISTING AND PROPOSED DEDICATED UTILITY
 EASEMENTS TO ALLOW ACCESS FOR CITY PERSONNEL TO
 PROPOSED UTILITY WATER METERS. VERIFY THAT THERE ARE NO
 STRUCTURES WITHIN EASEMENT.
 O PROVIDE ENLARGED VIEW ON PLANS OF PROPOSED LOCATION
 OF WATER METER AND BACKFLOW
 PREVENTION.
 O BACKFLOWS SHALL BE INSTALLED ON PRIVATE PROPERTY
 OUTSIDE OF EASEMENTS AND RIGHTS OF WAY. DOMESTIC WATER
 METERS SHALL BE INSTALLED IMMEDIATELY ADJACENT TO
 PROPERTY LINE. 3 INCH AND LARGER WATER METERS SHALL BE
 INSTALLED ABOVE-GROUND ONLY.
 O CALLOUT DOMESTIC BACKFLOW PREVENTER AS RPPA (MAKE
 NOTE USC APPROVED) AND FIRE BACKFLOW PREVENTER AS DCDA.
  
 WATER/WASTEWATER PLAN:
 O PROVIDE VERTICAL DATUM AND DATUM CONVERSION
 INFORMATION (NAVD 1988 AND NGVD 1929).
 O SHOW PROJECT ADDRESS ON ALL PLAN SHEETS.
 O PROVIDE LEGEND ON ALL PLAN SHEETS TO INCLUDE
 STREETLIGHT, SIGN POSTS, TRANSFORMER BOXES ETC.
 O PLANS SHALL SHOW EXISTING AND PROPOSED LOCATIONS AND
 DIMENSIONS OF ALL WATER, STORMWATER, AND SANITARY AND
 SEWER LINES AND CLEANOUTS, INCLUDING STUBS TO EACH
 PROPERTY LINE FOR WATER AND SANITARY SEWERS, THE MAKE
 AND MODEL OF ALL VALVES, POTABLE AND IRRIGATION METERS,
 BACKFLOWS, FIRE HYDRANTS AND FDCS, AND OTHER DEVICES TO
 BE INSTALLED ON THE SYSTEM, CATCH BASINS, CULVERTS,
 DITCHES INCLUDING GRADES, PIPES SIZES, MATERIALS,
 ELEVATIONS, ASSUMPTIONS, CALCULATIONS, INVERT
 ELEVATIONS FOR ALL INLETS AND MANHOLES AND PROFILES OF
 SANITARY SEWER LINES.
 O GATE VALVE BOXES SHALL NOT BE INSTALLED IN CURB OR
 SIDEWALK. ALL AVAILABLE ELEVATION SHALL BE SHOWN ON THE
 PROFILE VIEW.
 O DIRECTION OF FLOW SHALL BE SHOWN ON PLAN VIEW ON PLAN
 VIEW FOR ALL SANITARY AND STORM SEWERS.
 O SHOW SLOPE % ON ALL SANITARY LINES AND CALL OUT
 MATERIAL.
 O PLAN VIEW SHALL SHOW ALL EXISTING AND PROPOSED
 UNDERGROUND UTILITY LAYOUT, INCLUDING FIBER OPTIC,
 ELECTRIC, GAS, AND CABLEVISION & TELECOMMUNICATION
 FACILITIES INCLUDING PIPE SIZE AND MATERIAL LOCATED IN
 THE RIGHT-OF-WAY.
 O PROVIDE PROFILE AND CLEARANCES BETWEEN WATER, SEWER
 AND STORM LINES PER CITY OF WEST PALM BEACH STANDARD
 DETAIL GN-2 SERIES, AT ALL UTILITY CROSSINGS. PLEASE
 INCLUDE FIBER OPTIC, ELECTRIC, GAS, AND CABLEVISION &
 TELECOMMUNICATION FACILITIES INCLUDING PIPE SIZE AND
 MATERIAL LOCATED IN THE RIGHT-OF-WAY.
 O SUBMIT COMPLETED LOS ANALYSIS SUMMARY TABLE DIRECTLY
 TO ENGINEERING (SHEET 33 OF CITY OF WPB DEVELOPMENT
 APPLICATION). PROVIDE CALCULATIONS ON PLANS OF EXISTING
 AND PROPOSED DEMANDS FOR WATER & SEWER (AVERAGE,
 MAXIMUM AND PEAK) AND FIRE FLOW DEMANDS. CALCULATIONS
 SHALL BE PER FAC 64E-6 FOR SEWER AND PER FAC 64-E.008
 FOR WATER.
 O PROVIDE FIRE FLOW TEST DATA.
 O PROVIDE CCTV VIDEO OF EXISTING SANITARY SEWER
 INFRASTRUCTURE ALONG ENTIRE PROJECT FRONTAGE WHERE
 CONNECTION IS PROPOSED (CONDITION OF SITE PLAN
 APPROVAL).
 O CUT AND CAP UTILITIES NOT IN USE AND REMOVE ANY
 ABANDONED UTILITY LINES LARGER THAN 2 INCHES FROM CITY
 ROW.
 O WHEN PROPOSED, WATER MAINS IN CITY RIGHT OF WAY SHALL
 BE MADE OF DUCTILE IRON PIPE (NOT PVC) AND SPECIFY
 PROPOSED LENGTH IN FEET.
 O CHECK TO SEE IF FDEP FORMS FOR PROPOSED SANITARY
 SEWER ARE REQUIRED.
 O PROVIDE CLEANOUTS FOR PROPOSED SANITARY LINE ONSITE
 JUST INSIDE PROPERTY LINE, AT JOINTS AND EVERY 75 FEET.
 O ADD NOTE TO PLANS SPECIFYING CITY???S DOWNSTREAM LIFT
 STATION NUMBER.
 O PROVIDE ONSITE CLEANOUTS NEAR PROPERTY LINE FOR
 PROPOSED SANITARY LATERALS.
 O LABEL WATER LINES AS PRIVATE WHERE APPLICABLE.
 O PLEASE SHOW AND LABEL EXISTING AND PROPOSED GREASE
 TRAPS (IF ANY).
 O PER CITY STANDARDS MAINTAIN MINIMUM DISTANCE BETWEEN
 OUTSIDE DIAMETER OF CITY PIPE AND ROOT BARRIER.
  
 FORMAL ENGINEERING REVIEW:
 O FOR FORMAL ENGINEERING SUBMITTAL, SFWMD ERP AND NPDES
 NOI REQUIREMENTS WILL BE ENFORCED.
 - AN NOI IS REQUIRED FOR PROJECTS THAT:
 - 1) DISTURB ONE OF MORE ACRES OF LAND OR DISTURB LESS
 THAN ON ACRE OF LAND BUT ARE PART OF A COMMON PLAN OF
 DEVELOPMENT OR SALE;
 - 2) DISCHARGE STORMWATER TO SURFACE WATERS OF THE
 STATE OR TO SURFACE WATERS OF THE STATE THROUGH A
 MUNICIPAL SEPARATE STORM SEWER SYSTEM (MS4).
 - THE SFWMD ERP CAN BE OBTAINED THROUGH A 10-2 SELF
 CERTIFICATION THROUGH FDEP OR AN ERP APPLICATION
 THROUGH SFWMD. EITHER WAY, THE DEVELOPER/ENGINEER SHALL
 SUBMIT A COPY OF THE ERP PERMIT OR FDEP ACKNOWLEDGEMENT
 OF THE 10-2 CERTIFICATION.
 O FOR FORMAL ENGINEERING SUBMITTAL, PLEASE PROVIDE
 EASEMENT FOR PLACEMENT OF PROPOSED WATER METERS.
 O FOR FORMAL ENGINEERING SUBMITTAL, PROVIDE PROFILES OF
 WATER AND SEWER AND SHOW ANY CROSSINGS/CONFLICTS.
 O FOR FORMAL ENGINEERING SUBMITTAL, WHEN SUBMITTING
 APPROVED MATERIALS LIST, PLEASE PROVIDE MATERIAL/CUT
 SHEETS FOR ALL PROPOSED BACKFLOW DEVICES SHOWING
 SPECIFIC MODEL NUMBER AND SPECIFYING USC APPROVED
 LEAD-FREE DESIGN.
 O FOR FORMAL ENGINEERING SUBMITTAL, IF SANITARY LINES
 ARE PROPOSED IN ROW PLEASE SHOW ADJACENT SANITARY
 LATERAL LOCATIONS AND SHOW ADDRESSES OF ADJACENT
 PARCELS.
 O FOR FORMAL ENGINEERING SUBMITTAL, IF WATER LINES ARE
 BEING REPLACED IN ROW, SHOW ADJACENT PARCEL ADDRESSES.
 O FOR FORMAL ENGINEERING SUBMITTAL, ADD NOTE TO PROVIDE
 50 FT. PAVEMENT RESTORATION TRANSITION ON EACH SIDE OF
 PROPOSED TRENCH IN CITY MAINTAINED ROADWAY AREAS PER
 CITY OF WPB STANDARD DETAIL GC-8.
 O FOR FORMAL ENGINEERING SUBMITTAL, PLEASE PROVIDE
 CALCULATIONS OF PERVIOUS AND IMPERVIOUS AREAS FOR
 PROPOSED IMPROVED AREAS.
  
 QUESTIONS AND COORDINATION CONTACTS:
 O MARK HURLEY, FIELD CUSTOMER SERVICE SUPERVISOR WITH
 CITY OF WPB PUBLIC UTILITIES, REGARDING PLACEMENT OF
 BACKFLOW DEVICES AND WATER METERS. CONTACT HIM AT
 561-822-2262 OR [email protected]
 O MIKE TECHNOW, PROJECT ENGINEER, PUBLIC UTILITIES
 DEPARTMENT AT 561-494-1047 OR [email protected]
 O TRACY WARD, SR. STORMWATER ENGINEER, ENGINEERING
 SERVICES DEPT. AT 561-494-1120 OR [email protected]
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time 0.00
Received By   Date   Time   Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 09-29-2022 Cont ID  
Sent By pleduc Date 09-29-2022 Time   Rev Time 0.00
Received By pleduc Date 09-29-2022 Time 15:21 Sent To  
Notes
2022-09-29 15:28:55THE FOLLOWING COMMENTS WERE SUBMITTED BY PETER LEDUC,
 FIRE MARSHAL, BUREAU OF FIRE PREVENTION, WEST PALM
 BEACH FIRE DEPARTMENT.
  
 THIS REVIEW CAN ONLY BE CONSIDERED PRELIMINARY AS THE
 DRAWINGS THAT WERE REVIEWED WERE NOT COMPLETE.
 ADDITIONAL COMMENTS CAN BE EXPECTED WHEN FULL DRAWINGS
 ARE SUBMITTED FOR PERMIT.
  
 THE FIRE PREVENTION BUREAU HAS NO OBJECTIONS TO THE
 PROPOSED PROJECT. THE FOLLOWING COMMENTS ARE INTENDED
 TO PROVIDE GUIDANCE FOR BUILDING PLAN SUBMITTAL.
  
 1. CONSTRUCTION, DEMOLITION, AND RENOVATION TO COMPLY
 WITH NFPA 241. EXTRA ATTENTION SHALL BE GIVEN TO THE
 PERMITTING AND LOCATION OF CONSTRUCTION TRAILERS. A
 PERMIT IS REQUIRED FOR ANY CONSTRUCTION TRAILER RELATED
 TO THIS PROJECT. SEPARATION DISTANCES FROM MAIN
 STRUCTURES AS WELL AS OTHER TRAILERS SHALL BE CLOSELY
 MONITORED FOR THE REQUIREMENTS OF FIRE SPRINKLER
 PROTECTION.
  
 2. SITE ACCESS AND EXIT POINTS ARE TO BE CLEARLY
 IDENTIFIED AND MAINTAINED FOR EMERGENCY VEHICLES DURING
 ALL CONSTRUCTION ACTIVITIES.
  
 3. THE BUILDING ADDRESS SHALL BE CLEARLY VISIBLE FROM
 ALL ACCESS ROADWAYS, INCLUDING DURING CONSTRUCTION.
 ADDRESS NUMBERS SHALL CONTRAST WITH THEIR BACKGROUND
 AND SHALL NOT BE LESS THAN SIX (6) INCHES IN HEIGHT
 WITH A ONE (1) INCH STROKE FOR ALL BUILDINGS.
  
 4. DURING CONSTRUCTION, TRASH AND DEBRIS IS TO BE
 REMOVED FROM THE SITE DAILY OR MORE OFTEN TO REDUCE THE
 ACCUMULATION OF POTENTIAL LIFE AND FIRE SAFETY HAZARDS.
  
 5. THE CONSTRUCTION OF THE BUILDING(S) SHALL COMPLY
 WITH THE 7TH EDITION OF THE FLORIDA FIRE PREVENTION
 CODE, INCLUDING NFPA 1 & 101, AND ALL ASSOCIATED FIRE
 CODES.
  
 6. FOR PLAN REVIEW SUBMITTAL, PLEASE INCLUDE THE
 OCCUPANCY TYPE PER THE FLORIDA FIRE PREVENTION CODE.
  
 7. FOR PLAN REVIEW SUBMITTAL, PLEASE ENSURE THAT A FIRE
 LOAD CALCULATION IS INCLUDED, AND THAT ADEQUATE WATER
 SUPPLY IS EXISTING OR WILL BE PROVIDED.
  
 8. ALL EXISTING AND NEW FIRE HYDRANTS PLANNED FOR THIS
 DEVELOPMENT SHALL BE CLEARLY INDICATED AND IDENTIFIED
 ON THE PLAN AND CLOSELY COORDINATED WITH THE BUREAU OF
 FIRE PREVENTION.
  
 AN FDC IS LOCATED ON THE PROPOSED SITE PALN WITH AN
 EXISTING FIRE HYDRANT LOCATED NEARBY, HOWEVER, IT IS
 NOT INDICATED IF THERE IS A WALL OR FENCE SEPARATING
 THE TWO BEYOND THE 100' MAX DISTANCE.
  
 THE PROPOSED LOCATION OF THE FIRE HYDRANT AND FDC SHALL
 BE WITHIN 100' OF EACH OTHER AND, IF NEEDED, CLOSELY
 COORDINATED WITH THE BUREAU OF FIRE PREVENTION.
  
 9. PROVIDE FOR A FIRE SPRINKLER AND/OR FIRE ALARM PER
 THE APPLICABLE OCCUPANCY CODE. FOR ANY LIFE SAFETY
 ENGINEERED SYSTEM, I.E FIRE SPRINKLER AND FIRE ALARM,
 ENSURE THEY COMPLY WITH THE REQUIREMENTS OF F.A.C. 61G
 AND SUBMITTED WITH THE MASTER PERMIT.
  
 9A. THE LOCATION OF ANY APPLICABLE DDCV AND FIRE LINE
 LOCATIONS SHALL MEET AND BE INSTALLED PER THE
 REQUIREMENTS OF NFPA 24 AND SHALL BE COORDINATED WITH
 THE OFFICE OF FIRE MARSHAL, THE CITY'S ENGINEERS
 OFFICE, THE LANDSCAPE PLANNER, AND THE CITY'S PLANNING
 AND ZONING OFFICE.
  
 10. COMPLETE LIFE SAFETY PLANS FOR THE OCCUPANCY SHALL
 BE PROVIDED THAT ILLUSTRATE OCCUPANT LOADS, TRAVEL
 DISTANCES, EXIT SEPARATION DISTANCES, COMMON PATHS OF
 TRAVEL, DEAD-END CORRIDORS, EXIT SIGNS, EMERGENCY
 LIGHTING, EXITS LEADING TO A PUBLIC WAY, FIRE
 EXTINGUISHER LOCATIONS, AND ALL FIRE SAFETY FEATURES
 AND EQUIPMENT.
  
 11. IT IS HIGHLY RECOMMENDED (REQUIRED WITH FIRE
 SPRINKLER SYSTEM) THAT A KNOX BOX WITH KEYS FOR ENTRY
 DOOR LOCKS BE PROVIDED FOR 24 HOUR EMERGENCY ACCESS.
  
 12. AREAS OF REFUGE, IF APPLICABLE, SHALL BE PROVIDED
 AS REQUIRED PER THE FLORIDA BUILDING CODE AND NFPA 101,
 CH 7, MEANS OF EGRESS.
  
 13. TWO-WAY RADIO COMMUNICATIONS ENHANCEMENT SYSTEMS.
  
 NFPA 1, CHAPTER 11, BUILDING SERVICES; 11.10 TWO-WAY
 RADIO ENHANCEMENT SERVICES.
 11.10.1 IN ALL NEW AND EXISTING BUILDINGS, MINIMUM
 RADIO SIGNAL STRENGTH FOR FIRE DEPARTMENT
 COMMUNICATIONS SHALL BE MAINTAINED AT A LEVEL
 DETERMINED BY THE AHJ.
  
 IF NEEDED DUE TO POOR FD RADIO COMMUNICATIONS, CONTACT
 WILL NEED TO BE MADE TO MARK FILLA, PALM BEACH COUNTY
 PUBLIC SAFETY RADIO SYSTEMS MANAGER, [email protected],
 561-233-0837; AS OUR RADIOS OPERATE ON THEIR SYSTEM FOR
 DETAILED RADIO FREQUENCY AND INSTALLATION INSTRUCTIONS.
  
 14. THE BUREAU'S APPROVAL OF THIS SUBMITTED PROJECT
 DOES NOT CONSTITUTE ITS FINAL REVIEW OR APPROVAL.
  
 15. THE BUREAU SHALL REVIEW ALL SUBMITTED BUILDING
 PLANS AT THE APPROPRIATE TIME AND IN ACCORDANCE WITH
 THE REQUIREMENTS OF ALL APPLICABLE CODES AND STANDARDS.
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]
  

Review Stop L LANDSCAPING
Rev No 3 Status P Date 03-27-2023 Cont ID  
Sent By rcaranci Date 03-27-2023 Time 12:13 Rev Time 0.00
Received By rcaranci Date 03-27-2023 Time 12:13 Sent To  
Notes
2023-03-27 12:14:08FROM: RAY CARANCI, SENIOR LANDSCAPE PLANNER
 561-822-1462
 PROJECT: 2235 OKEECHOBEE Z22090007
 MARCH 27, 2023
 I HAVE REVIEWED THE ABOVE REFERENCED PETITION, AND
 PROVIDE THE FOLLOWING COMMENTS:
  
 1. SATISFIED. PROVIDE A TREE DISPOSITION AND MITIGATION
 LIST. SECTION 94-448 (D)(3) REQUIRES NATIVE TREES IN
 GOOD CONDITION TO BE PRESERVED ON SITE OR RELOCATED.
 ANSI A 300 (PART 5) STANDARDS SPECIFY EXAMPLES OF
 SUITABILITY RATINGS OF GOOD, MODERATE, OR POOR FOR
 RELOCATION. PROVIDE AN ARBORIST REPORT SHOWING
 CONDITION AND RELOCATION POTENTIAL FOR ANY NATIVE TREES
 OR PALMS TREES AND PALMS PROPOSED TO BE REMOVED.
 APPLICANT HAS INDICATED A TREE DISPOSITION LIST WILL BE
 PROVIDED WITH THE RESUBMITTAL.
 MAKE THE FOLLOWING CORRECTIONS TO THE TREE DISPOSITION
 CHART:
 ??? TREE #6 PLUMERIA IS CATEGORY 2, SO MITIGATION DUE
 IS 150 SQ FT.
 ??? TREE #56 QUEEN PALM IS CATEGORY 4, SO MITIGATION
 DUE IS 50 SQ FT.
 ??? WITH THE ABOVE CHANGES, REVISED TOTAL CANOPY
 MITIGATION SHOULD BE 1241 SQ FT.
  
 2. SATISFIED. THE SITE PLAN AND LANDSCAPE PLAN DO NOT
 MATCH THE SURVEY ALONG THE EAST PROPERTY LINE. THE
 PERVIOUS AREA IS OUTSIDE THE FENCE ON THE ADJACENT
 PROPERTY. CORRECT THE PLANS TO MATCH THE SURVEY. IF
 PERVIOUS AREA IS BEING ADDED, INDICATE THIS ON THE SITE
 PLAN AND PROVIDE THE REQUIRED LANDSCAPE BUFFER ALONG
 THE EAST PROPERTY LINE.
 THE VEHICLE OVERHANG IS OVERLAPPING 2 FEET OF THE 5
 FOOT BUFFER, ADJUST THE PARKING SPACE TO THE WEST TO
 ELIMINATE ENCROACHMENT INTO THE LANDSCAPE BUFFER.
  
  
 3. SATISFIED. PER SECTION 94-443(C)(3)A. AND B.,
 TERMINAL LANDSCAPE ISLANDS AND INTERIOR ISLANDS MUST
 HAVE AT LEAST 8 FEET WIDE LANDSCAPE AREA AND RUN THE
 FULL LENGTH OF THE ADJACENT PARKING SPACE. EACH AREA
 SHALL HAVE AT LEAST ONE SHADE OR FLOWERING TREE PER ROW
 OF PARKING AND AN INTERIOR ISLAND MUST BE PROVIDED SO
 THERE ARE NO MORE THAN 10 SPACES IN A ROW. PROVIDE THE
 REQUIRED LANDSCAPE ISLANDS FOR ALL REQUIRED PARKING.
 THERE ARE TERMINAL ISLANDS MISSING IN SEVERAL
 LOCATIONS.
 THE ROW OF PARKING DIRECTLY SOUTH OF THE NEW BUILDING
 IS LACKING A TERMINAL ISLAND ADJACENT TO THE BUILDING
 ON THE WEST END OF THE ROW. A TERMINAL ISLAND CURRENTLY
 EXISTS IN THIS LOCATION. THE INTERIOR LANDSCAPE ISLAND
 ADDED AT THE SOUTHWEST CORNER OF THE PARKING ROW
 ADJACENT TO OKEECHOBEE NEEDS TO BE LOCATED ON THE EAST
 SIDE OF THE ADA SPACES SO THERE ARE NO MORE THAN 10
 SPACES IN A ROW.
  
 4. SATISFIED. SECTION 94-443(C)(3) REQUIRES THAT A
 MINIMUM OF 75 PERCENT OF ALL TREES THAT ARE REQUIRED TO
 BE PLANTED WITHIN THE INTERIOR OF AN OFF STREET PARKING
 AREA SHALL BE CATEGORY 1 SHADE TREES. HIGH RISE OAK
 DOES NOT MEET THE INTENT OF PROVIDING TREE CANOPY FOR
 THE PARKING AREAS SO CANNOT BE COUNTED.
 MAKE ALL ADJUSTMENTS FROM OTHER COMMENTS AND
 RECALCULATE THIS.
  
  
 5. SATISFIED. PROVIDE AN EXHIBIT SHOWING THE PARKING
 AREA VEHICULAR USE AREA SURFACE CALCULATIONS, PARKING
 SPACE AREAS AND LANDSCAPE AREAS PROVIDED TO DEMONSTRATE
 COMPLIANCE WITH SECTIONS 94-443 (C)(3) AND (4). PROVIDE
 THE CORRECTED CALCULATIONS IN THE LANDSCAPE REQUIREMENT
 CHART. REFER TO FIGURE XIV-1. SHOW THE ACTUAL PROVIDED
 INTERIOR LANDSCAPE SQUARE FOOTAGE. BUFFERS AND
 NON-INTERIOR LANDSCAPING CANNOT BE COUNTED.
 ADDRESS THE MISSING TERMINAL ISLANDS FROM COMMENT #3
 AND ADJUST ON THE PLAN.
  
  
 6. SATISFIED. STORMWATER LINE AND EXFILTRATION PROPOSED
 ALONG THE EAST SIDE OF THE PARKING AREA CONFLICT WITH
 THE REQUIRED LANDSCAPE TERMINAL ISLAND AND TREE
 REQUIREMENT. ADJUST THE DRAINAGE LINE TO AVOID THE
 REQUIRED LANDSCAPING.
  
 7. SATISFIED. PROVIDE A DIAGRAM OF THE 30% REQUIRED
 AND PROVIDED LINEAR LANDSCAPE FOR AROUND EACH BUILDING
 INCLUDING THE CAR WASH BUILDING AS INDICATED IN THE
 CODE REQUIREMENT CHART. THE CODE REQUIRES TREES SHRUBS
 OR HEDGES.
 THE CALCULATIONS PROVIDED DO NOT CORRECTLY SHOW THE
 PERCENTAGE FOR EACH BUILDING. PROVIDE A DIAGRAM SHOWING
 COMPLIANCE.
  
  
 8. SATISFIED. IMPERVIOUS/LANDSCAPE AREA IS NOT WITHIN
 THE REQUIREMENT OF 15% OF THE SITE. STAFF SUGGESTS
 ADDING LANDSCAPE AREA TO MEET THE 15% REQUIRED. THERE
 ARE MANY OPPORTUNITIES THAT CAN BE IMPROVED IN THE
 STORAGE AREAS
  
 9. SATISFIED. UTILITY LINES ARE SHOWN, BUT THERE ARE
 MULTIPLE CONFLICTS WITH THE LOCATIONS OF LINES AND
 LANDSCAPING. ADJUST LOCATIONS OF UTILITIES TO AVOID
 LANDSCAPE AREAS.
  
 10. SATISFIED. MINIMUM NUMBER OF REQUIRED TREES IS NOT
 MET FOR THE SITE. ADD TREES TO MEET THE MINIMUM
 REQUIRED. UP TO 35% OF THE REQUIRED TREES CAN BE PALM
 SUBSTITUTIONS.
  
 11. SATISFIED. PROVIDE THE 50 REQUIRED FLORIDA FRIENDLY
 POINTS BASED ON THE FINAL PLANT LIST PER SECTION
 94-443(G) AFTER REVISIONS TO PLANS ARE MADE.
  
 CONDITIONS OF APPROVAL
 1. PRIOR TO THE REMOVAL OR RELOCATION OF ANY TREES ON
 THE PROPERTY, A TREE ALTERATION PERMIT SHALL BE
 SUBMITTED, REVIEWED AND APPROVED BY THE DEVELOPMENT
 SERVICES DEPARTMENT, PLANNING DIVISION.
 2. THE NONCONFORMITY FOR MEETING THE 15%
 LANDSCAPE/PERVIOUS AREA HAS BEEN REDUCED AND THE
 APPROVED PLANS WITH THIS PETITION PROVIDE 9.3%. ANY
 FUTURE CHANGES TO THE SITE CANNOT FALL BELOW THE
 APPROVED AREA.

Review Stop L LANDSCAPING
Rev No 2 Status F Date 01-10-2023 Cont ID  
Sent By rcaranci Date 01-10-2023 Time 16:46 Rev Time 0.00
Received By rcaranci Date 01-10-2023 Time 16:46 Sent To  
Notes
2023-01-10 16:46:31FROM: RAY CARANCI, SENIOR LANDSCAPE PLANNER
 561-822-1462
 PROJECT: 2235 OKEECHOBEE Z22090007
 JANUARY 6, 2023
 I HAVE REVIEWED THE ABOVE REFERENCED PETITION, AND
 PROVIDE THE FOLLOWING COMMENTS:
  
 1. PARTIALLY SATISFIED. PROVIDE A TREE DISPOSITION AND
 MITIGATION LIST. SECTION 94-448 (D)(3) REQUIRES NATIVE
 TREES IN GOOD CONDITION TO BE PRESERVED ON SITE OR
 RELOCATED. ANSI A 300 (PART 5) STANDARDS SPECIFY
 EXAMPLES OF SUITABILITY RATINGS OF GOOD, MODERATE, OR
 POOR FOR RELOCATION. PROVIDE AN ARBORIST REPORT SHOWING
 CONDITION AND RELOCATION POTENTIAL FOR ANY NATIVE TREES
 OR PALMS TREES AND PALMS PROPOSED TO BE REMOVED.
 APPLICANT HAS INDICATED A TREE DISPOSITION LIST WILL BE
 PROVIDED WITH THE RESUBMITTAL.
 MAKE THE FOLLOWING CORRECTIONS TO THE TREE DISPOSITION
 CHART:
 ??? TREE #6 PLUMERIA IS CATEGORY 2, SO MITIGATION DUE
 IS 150 SQ FT.
 ??? TREE #56 QUEEN PALM IS CATEGORY 4, SO MITIGATION
 DUE IS 50 SQ FT.
 ??? WITH THE ABOVE CHANGES, REVISED TOTAL CANOPY
 MITIGATION SHOULD BE 1241 SQ FT.
  
 2. PARTIALLY SATISFIED. THE SITE PLAN AND LANDSCAPE
 PLAN DO NOT MATCH THE SURVEY ALONG THE EAST PROPERTY
 LINE. THE PERVIOUS AREA IS OUTSIDE THE FENCE ON THE
 ADJACENT PROPERTY. CORRECT THE PLANS TO MATCH THE
 SURVEY. IF PERVIOUS AREA IS BEING ADDED, INDICATE THIS
 ON THE SITE PLAN AND PROVIDE THE REQUIRED LANDSCAPE
 BUFFER ALONG THE EAST PROPERTY LINE.
 THE VEHICLE OVERHANG IS OVERLAPPING 2 FEET OF THE 5
 FOOT BUFFER, ADJUST THE PARKING SPACE TO THE WEST TO
 ELIMINATE ENCROACHMENT INTO THE LANDSCAPE BUFFER.
  
  
 3. PARTIALLY SATISFIED. PER SECTION 94-443(C)(3)A. AND
 B., TERMINAL LANDSCAPE ISLANDS AND INTERIOR ISLANDS
 MUST HAVE AT LEAST 8 FEET WIDE LANDSCAPE AREA AND RUN
 THE FULL LENGTH OF THE ADJACENT PARKING SPACE. EACH
 AREA SHALL HAVE AT LEAST ONE SHADE OR FLOWERING TREE
 PER ROW OF PARKING AND AN INTERIOR ISLAND MUST BE
 PROVIDED SO THERE ARE NO MORE THAN 10 SPACES IN A ROW.
 PROVIDE THE REQUIRED LANDSCAPE ISLANDS FOR ALL REQUIRED
 PARKING. THERE ARE TERMINAL ISLANDS MISSING IN SEVERAL
 LOCATIONS.
 THE ROW OF PARKING DIRECTLY SOUTH OF THE NEW BUILDING
 IS LACKING A TERMINAL ISLAND ADJACENT TO THE BUILDING
 ON THE WEST END OF THE ROW. A TERMINAL ISLAND CURRENTLY
 EXISTS IN THIS LOCATION. THE INTERIOR LANDSCAPE ISLAND
 ADDED AT THE SOUTHWEST CORNER OF THE PARKING ROW
 ADJACENT TO OKEECHOBEE NEEDS TO BE LOCATED ON THE EAST
 SIDE OF THE ADA SPACES SO THERE ARE NO MORE THAN 10
 SPACES IN A ROW.
  
 4. PARTIALLY SATISFIED. SECTION 94-443(C)(3) REQUIRES
 THAT A MINIMUM OF 75 PERCENT OF ALL TREES THAT ARE
 REQUIRED TO BE PLANTED WITHIN THE INTERIOR OF AN OFF
 STREET PARKING AREA SHALL BE CATEGORY 1 SHADE TREES.
 HIGH RISE OAK DOES NOT MEET THE INTENT OF PROVIDING
 TREE CANOPY FOR THE PARKING AREAS SO CANNOT BE COUNTED.
 MAKE ALL ADJUSTMENTS FROM OTHER COMMENTS AND
 RECALCULATE THIS.
  
  
 5. PARTIALLY SATISFIED. PROVIDE AN EXHIBIT SHOWING THE
 PARKING AREA VEHICULAR USE AREA SURFACE CALCULATIONS,
 PARKING SPACE AREAS AND LANDSCAPE AREAS PROVIDED TO
 DEMONSTRATE COMPLIANCE WITH SECTIONS 94-443 (C)(3) AND
 (4). PROVIDE THE CORRECTED CALCULATIONS IN THE
 LANDSCAPE REQUIREMENT CHART. REFER TO FIGURE XIV-1.
 SHOW THE ACTUAL PROVIDED INTERIOR LANDSCAPE SQUARE
 FOOTAGE. BUFFERS AND NON-INTERIOR LANDSCAPING CANNOT BE
 COUNTED.
 ADDRESS THE MISSING TERMINAL ISLANDS FROM COMMENT #3
 AND ADJUST ON THE PLAN.
  
  
 6. SATISFIED. STORMWATER LINE AND EXFILTRATION PROPOSED
 ALONG THE EAST SIDE OF THE PARKING AREA CONFLICT WITH
 THE REQUIRED LANDSCAPE TERMINAL ISLAND AND TREE
 REQUIREMENT. ADJUST THE DRAINAGE LINE TO AVOID THE
 REQUIRED LANDSCAPING.
  
 7. PARTIALLY SATISFIED. PROVIDE A DIAGRAM OF THE 30%
 REQUIRED AND PROVIDED LINEAR LANDSCAPE FOR AROUND EACH
 BUILDING INCLUDING THE CAR WASH BUILDING AS INDICATED
 IN THE CODE REQUIREMENT CHART. THE CODE REQUIRES TREES
 SHRUBS OR HEDGES.
 THE CALCULATIONS PROVIDED DO NOT CORRECTLY SHOW THE
 PERCENTAGE FOR EACH BUILDING. PROVIDE A DIAGRAM SHOWING
 COMPLIANCE.
  
  
 8. SATISFIED. IMPERVIOUS/LANDSCAPE AREA IS NOT WITHIN
 THE REQUIREMENT OF 15% OF THE SITE. STAFF SUGGESTS
 ADDING LANDSCAPE AREA TO MEET THE 15% REQUIRED. THERE
 ARE MANY OPPORTUNITIES THAT CAN BE IMPROVED IN THE
 STORAGE AREAS
  
 9. SATISFIED. UTILITY LINES ARE SHOWN, BUT THERE ARE
 MULTIPLE CONFLICTS WITH THE LOCATIONS OF LINES AND
 LANDSCAPING. ADJUST LOCATIONS OF UTILITIES TO AVOID
 LANDSCAPE AREAS.
  
 10. SATISFIED. MINIMUM NUMBER OF REQUIRED TREES IS NOT
 MET FOR THE SITE. ADD TREES TO MEET THE MINIMUM
 REQUIRED. UP TO 35% OF THE REQUIRED TREES CAN BE PALM
 SUBSTITUTIONS.
  
 11. SATISFIED. PROVIDE THE 50 REQUIRED FLORIDA FRIENDLY
 POINTS BASED ON THE FINAL PLANT LIST PER SECTION
 94-443(G) AFTER REVISIONS TO PLANS ARE MADE.
  
 CONDITIONS OF APPROVAL
 1. PRIOR TO THE REMOVAL OR RELOCATION OF ANY TREES ON
 THE PROPERTY, A TREE ALTERATION PERMIT SHALL BE
 SUBMITTED, REVIEWED AND APPROVED BY THE DEVELOPMENT
 SERVICES DEPARTMENT, PLANNING DIVISION.
  

Review Stop L LANDSCAPING
Rev No 1 Status F Date 10-07-2022 Cont ID  
Sent By rcaranci Date 10-07-2022 Time 11:37 Rev Time 0.00
Received By rcaranci Date 10-07-2022 Time 11:37 Sent To  
Notes
2022-10-07 11:37:39FROM: RAY CARANCI, SENIOR LANDSCAPE PLANNER
 561-822-1462
 PROJECT: 2235 OKEECHOBEE Z22090007
 OCTOBER 6, 2022
 I HAVE REVIEWED THE ABOVE REFERENCED PETITION, AND
 PROVIDE THE FOLLOWING COMMENTS:
  
 1. PROVIDE A TREE DISPOSITION AND MITIGATION LIST.
 SECTION 94-448 (D)(3) REQUIRES NATIVE TREES IN GOOD
 CONDITION TO BE PRESERVED ON SITE OR RELOCATED. ANSI A
 300 (PART 5) STANDARDS SPECIFY EXAMPLES OF SUITABILITY
 RATINGS OF GOOD, MODERATE, OR POOR FOR RELOCATION.
 PROVIDE AN ARBORIST REPORT SHOWING CONDITION AND
 RELOCATION POTENTIAL FOR ANY NATIVE TREES OR PALMS
 TREES AND PALMS PROPOSED TO BE REMOVED. APPLICANT HAS
 INDICATED A TREE DISPOSITION LIST WILL BE PROVIDED WITH
 THE RESUBMITTAL.
  
 2. THE SITE PLAN AND LANDSCAPE PLAN DO NOT MATCH THE
 SURVEY ALONG THE EAST PROPERTY LINE. THE PERVIOUS AREA
 IS OUTSIDE THE FENCE ON THE ADJACENT PROPERTY. CORRECT
 THE PLANS TO MATCH THE SURVEY. IF PERVIOUS AREA IS
 BEING ADDED, INDICATE THIS ON THE SITE PLAN AND PROVIDE
 THE REQUIRED LANDSCAPE BUFFER ALONG THE EAST PROPERTY
 LINE.
  
 3. PER SECTION 94-443(C)(3)A. AND B., TERMINAL
 LANDSCAPE ISLANDS AND INTERIOR ISLANDS MUST HAVE AT
 LEAST 8 FEET WIDE LANDSCAPE AREA AND RUN THE FULL
 LENGTH OF THE ADJACENT PARKING SPACE. EACH AREA SHALL
 HAVE AT LEAST ONE SHADE OR FLOWERING TREE PER ROW OF
 PARKING AND AN INTERIOR ISLAND MUST BE PROVIDED SO
 THERE ARE NO MORE THAN 10 SPACES IN A ROW. PROVIDE THE
 REQUIRED LANDSCAPE ISLANDS FOR ALL REQUIRED PARKING.
 THERE ARE TERMINAL ISLANDS MISSING IN SEVERAL
 LOCATIONS.
  
 4. SECTION 94-443(C)(3) REQUIRES THAT A MINIMUM OF 75
 PERCENT OF ALL TREES THAT ARE REQUIRED TO BE PLANTED
 WITHIN THE INTERIOR OF AN OFF STREET PARKING AREA SHALL
 BE CATEGORY 1 SHADE TREES. HIGH RISE OAK DOES NOT MEET
 THE INTENT OF PROVIDING TREE CANOPY FOR THE PARKING
 AREAS SO CANNOT BE COUNTED.
  
 5. PROVIDE AN EXHIBIT SHOWING THE PARKING AREA
 VEHICULAR USE AREA SURFACE CALCULATIONS, PARKING SPACE
 AREAS AND LANDSCAPE AREAS PROVIDED TO DEMONSTRATE
 COMPLIANCE WITH SECTIONS 94-443 (C)(3) AND (4). PROVIDE
 THE CORRECTED CALCULATIONS IN THE LANDSCAPE REQUIREMENT
 CHART. REFER TO FIGURE XIV-1. SHOW THE ACTUAL PROVIDED
 INTERIOR LANDSCAPE SQUARE FOOTAGE. BUFFERS AND
 NON-INTERIOR LANDSCAPING CANNOT BE COUNTED.
  
 6. STORMWATER LINE AND EXFILTRATION PROPOSED ALONG THE
 EAST SIDE OF THE PARKING AREA CONFLICT WITH THE
 REQUIRED LANDSCAPE TERMINAL ISLAND AND TREE
 REQUIREMENT. ADJUST THE DRAINAGE LINE TO AVOID THE
 REQUIRED LANDSCAPING.
  
 7. PROVIDE A DIAGRAM OF THE 30% REQUIRED AND PROVIDED
 LINEAR LANDSCAPE FOR AROUND EACH BUILDING INCLUDING THE
 CAR WASH BUILDING AS INDICATED IN THE CODE REQUIREMENT
 CHART. THE CODE REQUIRES TREES SHRUBS OR HEDGES.
  
 8. IMPERVIOUS/LANDSCAPE AREA IS NOT WITHIN THE
 REQUIREMENT OF 15% OF THE SITE. STAFF SUGGESTS ADDING
 LANDSCAPE AREA TO MEET THE 15% REQUIRED. THERE ARE MANY
 OPPORTUNITIES THAT CAN BE IMPROVED IN THE STORAGE AREAS
  
 9. UTILITY LINES ARE SHOWN, BUT THERE ARE MULTIPLE
 CONFLICTS WITH THE LOCATIONS OF LINES AND LANDSCAPING.
 ADJUST LOCATIONS OF UTILITIES TO AVOID LANDSCAPE AREAS.
  
 10. MINIMUM NUMBER OF REQUIRED TREES IS NOT MET FOR THE
 SITE. ADD TREES TO MEET THE MINIMUM REQUIRED. UP TO 35%
 OF THE REQUIRED TREES CAN BE PALM SUBSTITUTIONS.
  
 11. PROVIDE THE 50 REQUIRED FLORIDA FRIENDLY POINTS
 BASED ON THE FINAL PLANT LIST PER SECTION 94-443(G)
 AFTER REVISIONS TO PLANS ARE MADE.
  
 CONDITIONS OF APPROVAL
 1. PRIOR TO THE REMOVAL OR RELOCATION OF ANY TREES ON
 THE PROPERTY, A TREE ALTERATION PERMIT SHALL BE
 SUBMITTED, REVIEWED AND APPROVED BY THE DEVELOPMENT
 SERVICES DEPARTMENT, PLANNING DIVISION.
  

Review Stop PARK PARKING
Rev No 1 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time  
Received By   Date   Time   Sent To  
Notes
***NONE***

Review Stop POLICE POLICE
Rev No 1 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time  
Received By   Date   Time   Sent To  
Notes
***NONE***

Review Stop PU-CS PUBLIC UTILITIES CUSTOMER SRVC
Rev No 2 Status P Date 12-28-2022 Cont ID  
Sent By mhurley Date 12-28-2022 Time 09:17 Rev Time 0.00
Received By mhurley Date   Time   Sent To  
Notes
***NONE***

Review Stop PU-CS PUBLIC UTILITIES CUSTOMER SRVC
Rev No 1 Status F Date 10-13-2022 Cont ID  
Sent By mhurley Date 10-13-2022 Time 07:17 Rev Time 0.00
Received By mhurley Date   Time   Sent To  
Notes
2022-10-13 07:17:10PLEASE PROVIDE WRITTEN RESPONSES TO THE FOLLOWING:
 -CANNOT LOCATE EXISTING FIRELINE BACKFLOW ASSEMBLY ON
 SITE WHERE SHOWN ON UTILITY PLAN. IF NONE ARE THERE,
 THEN ONE WOULD NEED TO BE INSTALLED. LABEL ON PLAN.
 -DOMESTIC METER CANNOT BE TAPPED OFF DEDICATED
 FIRELINE.
 -CALLOUT IS GOING OFF THE LEFT SIDE OF UTILITY PLAN AND
 UNREADABLE.
 -EXISTING 2 INCH DOMESTIC METER ON WEST SIDE OF
 PROPERTY HARD TO ACCESS DUE TO BUSHES. ADD REMOVAL OF
 BUSHES ENCROACHING WITHIN 18 INCHES OF METER BOX AND
 BACKFLOW ASSEMBLY.
 -VERIFY FIRE SYSTEM WILL NOT BE CONNECTED TO AN
 AUXILIARY WATER SUPPLY SUCH AS A WELL.
 -SHOW ALLEY PAVEMENT RESTORATION DUE TO UTILITY WORK.
 -LABEL ADDRESS OF ADJACENT PROPERTY TO THE EAST ON
 PLANS. THE ONE THAT HAS AN EASEMENT.
 -COULD NOT LOCATE FIRELINE VALVE ON SITE. NOT SURE IF
 BURIED UNDER LANDSCAPING AND BUSHES.
 -IS EXISTING 8 INCH SEWER REMAINING AND DOES IT HAVE
 ANY ADDITIONAL MANHOLE OR CLEANOUT AT ALLEY?
 RESPECTFULLY,
 MARK HURLEY [email protected]

Review Stop PW PUBLIC WORKS
Rev No 3 Status P Date 03-15-2023 Cont ID  
Sent By   Date 03-15-2023 Time   Rev Time 0.00
Received By   Date 03-15-2023 Time   Sent To  
Notes
2023-03-15 09:43:48NO FURTHER COMMENTS.

Review Stop PW PUBLIC WORKS
Rev No 2 Status F Date 12-19-2022 Cont ID  
Sent By   Date 12-19-2022 Time   Rev Time 0.00
Received By   Date 12-19-2022 Time   Sent To  
Notes
2022-12-19 14:50:36PLEASE PROVIDE:
 1- DUMPSTER ENCLOSURE DETAILS, SHEET C-06, TO COMPLY
 WITH THE CITY`S DUSMPTER ENCLOSURE SPECIFICATIONS. FOR
 A FREESTANDING SITE DUMPSTER ENCLOSURE, THE ENCLOSURE
 SHALL COMPLY WITH THE LATEST REVISION OF CITY OF WEST
 PALM BEACH GENERAL CONSTRUCTION-GARBAGE ENCLOSURE
 STANDARD, GC-7. (LINK TO THE LATEST REVISION OF THE
 GC-7 DOCUMENT: HTTPS://WWW.WPB.ORG/HOME/SHOWPUBLISHEDDO
 CUMENT/3690/637629060422100000)
 2- REVISED AUTOTURN EXHIBIT WITH DYNAMIC ENVELOPE AND
 THE VEHICLE???S WHEEL PATH IDENTIFIED WITH DIFFERENT
 COLORS FOR THE SANITATION SERVICE, FRONT LOADER TRUCK
 WITH THE FOLLOWING SPECS FROM THE INBOUD DIRECTIONS AND
 THROUGH OUTBOUNDS.
 - DUAL AXLES
 - TRUCK LENGTH: 35 FT
 - TRUCK WIDTH: 11 FT
 - TURNING RADIUS:
 - SAE TURNING RADIUS: 32.5 FT
 - CURB-TO-CURB DIAMETER: 74 FT
 - WALL-TO-WALL DIAMETER: 86.3 FT
  
 MATT HEJAZI
 DEPT. OF PUBLIC WORKS
 [email protected]
 561-822-2045

Review Stop PW PUBLIC WORKS
Rev No 1 Status F Date 10-06-2022 Cont ID  
Sent By   Date 10-06-2022 Time   Rev Time  
Received By   Date 10-06-2022 Time   Sent To  
Notes
2022-10-06 10:33:02PLEASE PROVIDE THE FOLLOWINGS:
 1- LOS (LEVEL OF SERVICE ANALYSIS) TO REFLECT THE SOLID
 WASTE VOLUME PRODUCED ALONG WITH THE SIZE, TYPE AND
 QUANTITY OF THE CONTAINER (I.E. DUMPSTER/COMPACTOR)
 THAT WILL BE UTILIZED FOR THE SANITATION SERVICE.
 2- DETAILS FOR SANITATION SERVICE (I.E. SOLID WASTE
 CONTAINER(S) TYPE, COLLECTION LOCATION, ETC.). DUMPSTER
 ENCLOSURE DETAILS. FOR A FREESTANDING SITE DUMPSTER
 ENCLOSURE, THE ENCLOSURE SHALL COMPLY WITH THE LATEST
 REVISION OF CITY OF WEST PALM BEACH GENERAL
 CONSTRUCTION-GARBAGE ENCLOSURE STANDARD, GC-7. (LINK TO
 THE LATEST REVISION OF THE GC-7 DOCUMENT: HTTPS://WWW.W
 PB.ORG/HOME/SHOWPUBLISHEDDOCUMENT/3690/6376290604221000
 00)
 3- AUTOTURN EXHIBIT WITH DYNAMIC ENVELOPE AND THE
 VEHICLE???S WHEEL PATH IDENTIFIED WITH DIFFERENT COLORS
 FOR THE SANITATION SERVICE, FRONT LOADER TRUCK WITH THE
 FOLLOWING SPECS:
 - DUAL AXLES
 - TRUCK LENGTH: 35 FT
 - TRUCK WIDTH: 11 FT
 - TURNING RADIUS:
 - SAE TURNING RADIUS: 32.5 FT
 - CURB-TO-CURB DIAMETER: 74 FT
 - WALL-TO-WALL DIAMETER: 86.3 FT
  
 4- OWNERS AND/OR OCCUPANTS OF PROPERTY THAT REQUIRE
 GREASE HAULING SERVICES SHALL ENSURE THAT THEIR GREASE
 TANKS OR CONTAINERS REMAIN CLEAN, AND ARE ENCLOSED AND
 NOT IN PUBLIC VIEW.
 5- IN CASE OF PROPOSING ADDITION OF ANY NEW CAN(S) IN
 THE CITY`S RIGHT-OF-WAY , THE LOCATION AND QUANTITY OF
 THE CAN(S) SHALL BE REVIEWED AND APPROVED BY PUBLIC
 WORKS DEPARTMENT AND THE CAN(S) SHALL BE TYPE, SIZE AND
 COLOR APPROVED BY PUBLIC WORKS DEPARTMENT. THE BUILDING
 MAINTENANCE IS RESPONSIBLE TO MAINTAIN AND SERVICE THE
 CAN(S).
 6- ALL THE PARKING STALL PAINTING SHALL COMPLY WITH THE
 CITY`S MUNICIPAL CODE SECTION 94-485 AND FLORIDA
 STATUES [553.5041 F.S.].
 7- SIGNAGE PLAN. ALL STRIPING AND SIGNAGE SHALL COMPLY
 WITH THE LATEST CITY OF WEST PALM BEACH STANDARD
 DETAILS AND MEET THE M.U.T.C.D. LATEST EDITION.
 8- ALL PAVEMENT MARKING , SIGNING AND SIDEWALK DAMAGED
 DURING CONSTRUCTION SHALL BE RESTORED.
  
  
 MATT HEJAZI
 DEPT. OF PUBLIC WORKS
 [email protected]
 561-822-2045

Review Stop STORM STORMWATER
Rev No 2 Status P Date 03-07-2023 Cont ID  
Sent By tward Date 03-07-2023 Time 11:28 Rev Time 0.00
Received By tward Date 03-07-2023 Time 11:29 Sent To  
Notes
***NONE***

Review Stop STORM STORMWATER
Rev No 1 Status F Date 10-13-2022 Cont ID  
Sent By tward Date 10-13-2022 Time 00:06 Rev Time 0.00
Received By tward Date 10-13-2022 Time 00:07 Sent To  
Notes
2022-10-13 00:06:45THIS IS A CONCEPTUAL LEVEL REVIEW. CONSTRUCTION LEVEL
 DETAILS, DESIGN CALCULATIONS AND THE POLLUTION
 PREVENTION PLAN WILL BE REVIEWED AS PART OF THE
 ENGINEERING DEVELOPMENT APPROVAL AND BUILDING PERMIT
 APPLICATION PROCESSES.
  
 THE FOLLOWING COMMENTS MUST BE ADDRESSED PRIOR TO SITE
 PLAN APPROVAL:
  
 1. OKEECHOBEE BLVD IS MAINTAINED BY FDOT. CONGRESS AVE
 IS MAINTAINED BY PALM BEACH COUNTY. ANY WORK WITHIN
 EITHER R/W WILL REQUIRE APPROVAL FROM THE RESPECTIVE
 AGENCY.
  
 2. REPLACE THE DRIVEWAY APRONS AND DROP CURBS FOR THE
 DRIVEWAYS THAT WILL ARE BEING ELIMINATED FROM THE SITE
 PLAN.
  
 3. INDICATE IF THE EXISTING BOLLARDS ALONG THE SOUTH
 PROPERTY LINE ARE TO BE REMOVED OR REPLACED. THE
 CONSTRUCTION OF THE STORM PIPE MAY HAVE AN IMPACT ON
 SOME OF THE BOLLARDS.
  
 4. CONSIDER PROVIDING 2 FEET OF LANDSCAPE OVERHANG FOR
 THE PARKING SPACES ALONG THE SOUTH PROPERTY LINE AND
 CONSTRUCTING TYPE D CURB INSTEAD OF TYPE F CURB AND
 GUTTER. CONSIDER PROVIDING 2 FEET OF LANDSCAPE OVERHANG
 FOR THE PARKING SPACES ALONG THE EAST PROPERTY LINE.
  
 5. THE EXISTING WEST PIPE TO STRUCTURE #19 IS SHOWN TO
 BE REMOVED ON THE DEMOLITION PLAN BUT A NEW PIPE IS NOT
 SHOWN ON THE PDG PLAN.
  
 6. CONSIDER USING A DIAGONAL HATCH PATTERN ON THE
 DEMOLITION PLAN TO INDICATE THE ITEMS TO BE REMOVED.
  
 7. BE CONSISTENT IN THE VERTICAL DATUM USED ON THE
 SURVEY AND ENGINEERING PLANS. THE SURVEY LISTS
 NGVD1929. THE ENGINEERING PLANS LIST NAVD1988. PROVIDE
 THE CONVERSION EQUATION BETWEEN NGVD1929 AND NAVD1988
 IF NAVD1988 IS USED. LIST THE VERTICAL DATUM AND
 CONVERSION EQUATION (IF APPLICABLE) ON EVERY SHEET WITH
 ELEVATION INFORMATION.
  
 8. INCLUDE PRB???S IN STRUCTURES ATTACHED TO
 EXFILTRATION TRENCHES TO PROLONG THE LIFE OF THE
 EXFILTRATION TRENCHES. PROVIDE A PRB DETAIL.
  
 9. CONSIDER ADDING A TRENCH DRAIN AT THE BOTTOM OF THE
 RAMP ON THE WEST SIDE OF THE PROPOSED BUILDING TO
 COLLECT THE RUNOFF COMING DOWN THE RAMP.
  
 10. THE SURVEY DOES NOT IDENTIFY THE AE13.4 FLOOD ZONE
 AT THE NORTHEAST AREA OF THE SITE.
  
 11. STRUCTURES WITHIN A SPECIAL FLOOD HAZARD AREA ARE
 REQUIRED TO HAVE A MINIMUM OF 2 FEET OF FREEBOARD ABOVE
 THE BASE FLOOD ELEVATION.
  
 12. PROVIDE A SCALE BAR ON THE SURVEY.
  
 13. THE PGD PLAN CALLS OUT TWO CONTROL STRUCTURES.
  
 14. ADD LEADERS TO THE STRUCTURE AND PIPE LABELS. WHERE
 IS STRUCTURE #8?
  
 15. DON???T SHOW ON THE PGD PLAN EXISTING STORM PIPE
 AND STRUCTURES THAT ARE BEING REMOVED.
  
 16. CONTROL STRUCTURE DETAIL LABELS THE WEIR ELEVATION
 AS 13.50 FEET NAVD1988. THE EXFILTRATION TRENCH DETAIL
 LABELS THE WEIR ELEVATION AS 16.50 FT NAVD AND THE
 LOWEST FINISHED GRADE AS 15.00 FT NAVD.
  
 17. LABEL EXISTING UTILITIES (SIZE, MATERIAL) ON THE
 PGD PLAN.
  
  
 THE FOLLOWING COMMENTS MUST BE ADDRESSED PRIOR TO
 ISSUANCE OF CONSTRUCTION AUTHORIZATION INCLUDING
 BUILDING PERMITS AND ENGINEERING DEVELOPMENT APPROVAL.
  
 1. DRAINAGE SYSTEM TO BE DESIGNED TO MEET SFWMD ERP
 CRITERIA. STORMWATER CALCULATIONS WILL BE REVIEWED WITH
 THE ENGINEERING PERMIT SUBMITTAL.
  
 2. PROVIDE COPY OF SFWMD ERP PERMIT BEFORE START OF
 CONSTRUCTION.
  
 3. PROVIDE EROSION AND SEDIMENT CONTROL PLAN WITH THE
 ENGINEERING PERMIT SUBMITTAL.
  
  
 TRACY WARD, PE
 SENIOR STORMWATER ENGINEER
 ENGINEERING SERVICES DEPARTMENT
 561-494-1120 (O)
 [email protected]
  

Review Stop SURVEY SURVEYING
Rev No 2 Status P Date 03-06-2023 Cont ID  
Sent By vnoel Date 03-06-2023 Time 10:12 Rev Time 0.00
Received By vnoel Date   Time   Sent To  
Notes
***NONE***

Review Stop SURVEY SURVEYING
Rev No 1 Status F Date 10-11-2022 Cont ID  
Sent By vnoel Date 10-11-2022 Time 13:17 Rev Time  
Received By vnoel Date   Time   Sent To  
Notes
2022-10-11 13:40:291. BOUNDARY/ALTA SURVEY REQUIRED, NOT JUST TOPOGRAPHIC.
 2. NEED LEGAL DESCRIPTION. ADD CONVERSION TO NGVD-29 ON
 ALL PLANS.
 3. HARD TO DELINEATE WHAT IS BEING DEMOLISHED AND WHAT
 IS PROPOSED.
  

Review Stop TRAFFIC TRAFFIC ENGINEERING
Rev No 3 Status P Date 03-15-2023 Cont ID  
Sent By   Date 03-15-2023 Time   Rev Time 0.00
Received By   Date 03-15-2023 Time   Sent To  
Notes
2023-03-15 10:54:291) SATISFIED. PROVIDE COUNTY TPS LETTER, ONCE RECEIVED
 2) SATISFIED. PROVIDE A PARKING TABLE SHOWCASING THE
 NUMBER OF REQUIRED AND PROVIDED PARKING SPACES,
 INCLUSIVE OF ADA AND BICYCLE ONES. PROVIDE DOCUMENT
 NAME AND SHEET NUMBER CONTAINING SUCH INFORMATION
 3) SATISFIED. PROVIDE AN ACCESSIBILITY ROUTE FOR EACH
 ADA STALL
 4) SATISFIED. MINIMUM DRIVE AISLE IS 24-FEET FOR EITHER
 90-DEGREE PARKING ANGLE OR TWO-WAY DIRECTION MOVEMENT.
 SOME OF THE PROPOSED DRIVE AISLES ARE 20-FEET, PLEASE
 CORRECT. THE 20-FEET WIDTH COULD BE ACCEPTABLE IF
 UTILIZED BY DEALERSHIP PERSONNEL. PLEASE INSTALL
 SIGNAGE AND/OR PAVEMENT MARKING TO LIMIT PUBLIC ACCESS
 TO SUCH DRIVE AISLES.
 5) SATISFIED. PROVIDE ENGINEERING REFERENCE AND SPECS
 SHEETS FOR THE ADA PARKING STALLS, VERIFY COMPLIANCE
 ACCORDINGLY. PROVIDE DOCUMENT NAME AND SHEET NUMBER
 CONTAINING SUCH INFORMATION
 6) SATISFIED. PROVIDE AUTOTURN ANALYSIS FOR GARBAGE
 TRUCK AND/OR SERVICE VEHICLES DRIVING IN AND OUT OF THE
 PROPOSED DEVELOPMENT WITH VEHICLE DYNAMIC ENVELOPES AND
 WHEEL PATHS CLEARLY DISTINCT AND DEFINED IN DIFFERENT
 COLORS. PROVIDE DOCUMENT NAME AND SHEET NUMBER
 CONTAINING SUCH ANALYSIS. LATEST SUBMISSION IS NOT
 SUFFICIENT AND NOT SHOWING THE
 7) SATISFIED. PROVIDE A VALET OPERATIONAL ANALYSIS.
 PLEASE PROVIDE A SHORT NARRATIVE AND SHOWCASE
 PICK-UP/DROP-OFF LOCATION(S), VALET PARKING STALLS, AND
 TYPICAL VALET VEHICLE CIRCULATION TO/FROM SUCH STALLS
  
 VALERIO ORICCHIO
 CITY TRANSPORTATION ENGINEER
 561-494-1092
 [email protected]
  

Review Stop TRAFFIC TRAFFIC ENGINEERING
Rev No 2 Status F Date 01-13-2023 Cont ID  
Sent By   Date 01-13-2023 Time   Rev Time 0.00
Received By   Date 01-13-2023 Time   Sent To  
Notes
2023-01-13 19:11:451) PARTIALLY SATISFIED. PROVIDE COUNTY TPS LETTER, ONCE
 RECEIVED
 2) SATISFIED. PROVIDE A PARKING TABLE SHOWCASING THE
 NUMBER OF REQUIRED AND PROVIDED PARKING SPACES,
 INCLUSIVE OF ADA AND BICYCLE ONES. PROVIDE DOCUMENT
 NAME AND SHEET NUMBER CONTAINING SUCH INFORMATION
 3) SATISFIED. PROVIDE AN ACCESSIBILITY ROUTE FOR EACH
 ADA STALL
 4) PARTIALLY SATISFIED. MINIMUM DRIVE AISLE IS 24-FEET
 FOR EITHER 90-DEGREE PARKING ANGLE OR TWO-WAY DIRECTION
 MOVEMENT. SOME OF THE PROPOSED DRIVE AISLES ARE
 20-FEET, PLEASE CORRECT. THE 20-FEET WIDTH COULD BE
 ACCEPTABLE IF UTILIZED BY DEALERSHIP PERSONNEL. PLEASE
 INSTALL SIGNAGE AND/OR PAVEMENT MARKING TO LIMIT PUBLIC
 ACCESS TO SUCH DRIVE AISLES.
 5) SATISFIED. PROVIDE ENGINEERING REFERENCE AND SPECS
 SHEETS FOR THE ADA PARKING STALLS, VERIFY COMPLIANCE
 ACCORDINGLY. PROVIDE DOCUMENT NAME AND SHEET NUMBER
 CONTAINING SUCH INFORMATION
 6) NOT SATISFIED. PROVIDE AUTOTURN ANALYSIS FOR GARBAGE
 TRUCK AND/OR SERVICE VEHICLES DRIVING IN AND OUT OF THE
 PROPOSED DEVELOPMENT WITH VEHICLE DYNAMIC ENVELOPES AND
 WHEEL PATHS CLEARLY DISTINCT AND DEFINED IN DIFFERENT
 COLORS. PROVIDE DOCUMENT NAME AND SHEET NUMBER
 CONTAINING SUCH ANALYSIS. LATEST SUBMISSION IS NOT
 SUFFICIENT AND NOT SHOWING THE
 7) PROVIDE A VALET OPERATIONAL ANALYSIS. PLEASE PROVIDE
 A SHORT NARRATIVE AND SHOWCASE PICK-UP/DROP-OFF
 LOCATION(S), VALET PARKING STALLS, AND TYPICAL VALET
 VEHICLE CIRCULATION TO/FROM SUCH STALLS
  
 VALERIO ORICCHIO
 CITY TRANSPORTATION ENGINEER
 561-494-1092
 [email protected]
  
  
  

Review Stop TRAFFIC TRAFFIC ENGINEERING
Rev No 1 Status F Date 10-13-2022 Cont ID  
Sent By   Date 10-13-2022 Time   Rev Time  
Received By   Date 10-13-2022 Time   Sent To  
Notes
2022-10-13 07:19:271) PROVIDE COUNTY TPS LETTER, ONCE RECEIVED
 2) PROVIDE A PARKING TABLE SHOWCASING THE NUMBER OF
 REQUIRED AND PROVIDED PARKING SPACES, INCLUSIVE OF ADA
 AND BICYCLE ONES. PROVIDE DOCUMENT NAME AND SHEET
 NUMBER CONTAINING SUCH INFORMATION
 3) PROVIDE AN ACCESSIBILITY ROUTE FOR EACH ADA STALL
 4) MINIMUM DRIVE AISLE IS 24-FEET FOR EITHER 90-DEGREE
 PARKING ANGLE OR TWO-WAY DIRECTION MOVEMENT. SOME OF
 THE PROPOSED DRIVE AISLES ARE 20-FEET, PLEASE CORRECT
 5) PROVIDE ENGINEERING REFERENCE AND SPECS SHEETS FOR
 THE ADA PARKING STALLS, VERIFY COMPLIANCE ACCORDINGLY.
 PROVIDE DOCUMENT NAME AND SHEET NUMBER CONTAINING SUCH
 INFORMATION
 6) PROVIDE AUTOTURN ANALYSIS FOR GARBAGE TRUCK AND/OR
 SERVICE VEHICLES DRIVING IN AND OUT OF THE PROPOSED
 DEVELOPMENT WITH VEHICLE DYNAMIC ENVELOPES AND WHEEL
 PATHS CLEARLY DISTINCT AND DEFINED IN DIFFERENT COLORS.
 PROVIDE DOCUMENT NAME AND SHEET NUMBER CONTAINING SUCH
 ANALYSIS
  
 VALERIO ORICCHIO
 CITY TRANSPORTATION ENGINEER
 561-494-1092
 [email protected]
  

Review Stop Z ZONING
Rev No 3 Status P Date 04-03-2023 Cont ID  
Sent By vbroglia Date 04-03-2023 Time 16:22 Rev Time 0.00
Received By vbroglia Date 04-03-2023 Time 16:22 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status F Date 01-05-2023 Cont ID  
Sent By vbroglia Date 01-05-2023 Time 11:53 Rev Time 0.00
Received By vbroglia Date 01-05-2023 Time 11:52 Sent To  
Notes
2023-01-06 14:20:56CASE NO. Z22090021
 PROJECT NAME: MAROONE CHEVROLET
 LOCATION: 2235 OKEECHOBEE BLVD
  
 CONTACT: VALENTINA BROGLIA, PLANNER AT (561) 822-1442
 OR [email protected]
  
 PLEASE PROVIDE WRITTEN RESPONSES TO THE FOLLOWING
 REVIEW COMMENTS:
 1. TPS LETTER IS REQUIRED FOR THIS PROJECT TO MOVE
 FORWARD
 2. PLEASE RELOCATE THE BIKE RACK TO MEET THE ZONING
 CODE REQUIREMENTS PER SECTION 94-485(2)(C) (8-11).
 PLEASE NOTE A WAVE BIKE RACK IS NOT A PERMITTED DESIGN
 IN THE CITY OF WEST PALM BEACH, PLEASE CHANGE DESIGN TO
 A SINGLE LOOP U OR AN INVERTED ???U??? OR LIKE THESE.
 PLEASE PROVIDE DIMENSIONS OF THE CONCRETE PAD WHERE THE
 BIKE RACK WILL BE LOCATED SHOWN ON THE SITE PLAN
 3. PLEASE INDICATE IF THE ONE-WAY ACCESS DRIVE ON THE
 EAST SIDE OF THE PROPERTY WILL BE ACCESSIBLE FOR PUBLIC
 PARKING OR IF USED FOR STORAGE OF INVENTORY ONLY- NOTE:
 LANDSCAPE ISLANDS PER EVERY TEN PARKING SPACES ARE
 REQUIRED IF PUBLIC CAN USE AS PARKING.
 4. ON THE EAST SIDE OF THE PROPERTY PLEASE INCREASE THE
 5-FOOT BUFFER TO A 7-FOOT BUFFER FOR LANDSCAPING
 PURPOSES (SHRUBS/TREES).
 5. PLEASE INDICATE ON SITE PLAN THAT ROOFTOP IS FOR
 DISPLAYING VEHICLES ONLY, OR IF ALSO FOR STORAGE.
 6. PLEASE SHOW THE NUMBER OF SMALL PARKING SPACES ARE
 PROPOSED ON THE SITE PLAN, NOTE 30 PERCENT OF THE
 SPACES MAY BE DESIGNATED FOR SMALL CAR USE. PER SECTION
 94-485(N)(1)(D) ALL SMALL CAR PARKING SPACES SHALL BE
 MARKED WITH INDIVIDUAL SIGNS/PAVEMENT MARKINGS STATING,
 "SMALL CARS ONLY." SMALL CAR PARKING SPACES SHALL HAVE
 DOUBLE STRIPING ON EACH SIDE OF THE SPACE.
 7. PLEASE SHOW THE CURB LENGTH ON THE SITE PLAN TO MEET
 THE GENERAL PARKING DIMENSIONS REQUIREMENTS LISTED ON
 FIGURE XV-2 IN SECTION 94-485
 8. PROPOSED PARKING BY THE CONCRETE STEPS DO NOT APPEAR
 TO PROVIDE REQUIRED TURN AROUND SPACE/AISLE CLEARANCE.
 PLEASE ALSO SHOW DIMENSIONS OF PARKING STALLS.
 9. PLEASE INDICATE IF THE LEFT MOST CONCREATE STEPS,
 ADJACENT TO THE TWO PARKING SPACES PROPOSED HAVE ACCESS
 INTO THE PARKING LOT/WOULD BE BLOCKED BY PARKED
 VEHICLE.
  
 -WHEN RESUBMITTING, PLEASE PROVIDE A MINIMUM OF THREE
 (3) PAPER COPIES AND DIGITAL PLANS IN .PNG/.PDF FORMAT
 OF ALL THE PLANS. PLEASE NOTE THAT CHANGES ON THE
 RESUBMITTED PLANS OR THE SUBMITTAL OF INFORMATION/PLANS
 TO ADDRESS THE COMMENTS MAY RESULT IN ADDITIONAL
 COMMENTS.
  
 -PLEASE NOTE THAT IS THE PLANNING DIVISION HAS NOT
 RECEIVED A RESPONSE TO THE PPRC COMMENTS/REVIEW COMMENT
 WITHIN 60 DAYS FROM THE DATE OF THE PPRC
 MEETING/COMMENT ISSUANCE (BY **), THE PLANNING DIVISION
 MAY NOTIFY THE APPLICANT THAT THE CASE IS CONSIDERED
 WITHDRAWN. ANY FURTHER ACTION WILL REQUIRE A NEW
 DEVELOPMENT APPLICATION.
  
 -PLEASE NOTE THAT YOU WILL BE PERMITTED ONE (1)
 RESUBMITTAL AT NO ADDITIONAL COST. IF PREVIOUSLY ISSUED
 COMMENTS CONTINUE TO NOT BE SUFFICIENTLY ADDRESSED, THE
 APPLICANT WILL BE ASSESSED A RESUBMITTAL FEE, SUCH FEE
 WILL BE 20% OF THE ORIGINAL APPLICATION FEE
  
  

Review Stop Z ZONING
Rev No 1 Status F Date 10-13-2022 Cont ID  
Sent By vbroglia Date 10-13-2022 Time 09:07 Rev Time 0.00
Received By vbroglia Date 10-13-2022 Time 09:06 Sent To  
Notes
2022-10-13 09:18:031. IF THE EXISTING SERVICE BAYS ARE NOT ENCLOSED, THEY
 CANNOT COUNT TOWARDS THE SQUARE FOOTAGE DECREASE AND
 ACCOUNTED FOR THE PROPOSED SQUARE FOOT INCREASE
  
 2. PLEASE INDICATE THE SQUARE FEET PROPOSED OF THE CAR
 WASH
  
 3. PLEASE SHOW CAR WASH EXIT ISLE WIDTH TO INDICATE
 THERE IS ENOUGH TURNING ROOM BETWEEN THE EXIT AND
 PARKING SPACES PROPOSED
  
 4. PARKING SPACE ON THE SOUTHEAST CORNER BY THE CURB
 CUT OPENING WITH ADJACENT PROPERTY SEEMS TO NOT BE THE
 REQUIRED DIMENSIONS PER THE ZONING CODE, PLEASE CLARIFY
 WHAT THE DASHED LINE SHOWN ON THE SITE PLAN INDICATES.
  
 5 .LANDSCAPE ISLANDS ARE REQUIRED PER EVERY 10 PARKING
 SPACES USED TO PUBLIC PARKING
  
 6. LANDSCAPE ISLAND SHOULD MEASURE THE SAME LENGTH AS
 THE PARKING SPACE???S LENGTH
  
 7. DRIVING AISLE ON THE EAST SIDE OF THE PROPOSED
 SERVICE DRIVE IS PROPOSED TO BE 31.75??? PLEASE REDUCE
 THIS TO A MINIMUM OF 24??? AISLE WIDTH AND INCREASE THE
 LANDSCAPE BUFFER (THIS WILL AID IN MEETING THE
 LANDSCAPE REQUIREMENTS)
  
 8. PARKING SPACES ON THE SOUTH SIDE OF THE INSPECTION
 BAY, SEEM TO BE BACKING UP INTO INGRESS AND EGRESS OF
 THE PARKING LOT, PLEASE SHOW FUNCTION OF SPACE.
  
 9. SURVEY SHOWS A ???COVERED WORK BAY??? AND SITE PLAN
 INDICATES A ???PRE-INSPECTION BAY??? PLEASE CLARIFY THE
 USE AND IF EXISTING SPACE IS ENCLOSED OR PROPOSED TO BE
 ENCLOSED
  
 10. PLEASE SHOW THE AISLE WIDTH ON THE CAR RAMP
 PROPOSED
  
 11.PROPOSED COSTUMER PARKING ON THE NORTH SIDE OF THE
 BUILDING NEEDS TO BE 18 FEET IN LENGTH PER ZONING CODE
 OF A STANDARD 90 DEGREE PARKING ANGLE
  
 12. SEPERATE PERMITS REQUIRED FOR PARKING LOT AND
 LANDSCAPING. OTHER.
  
  