Plan Review Details - Project Z22080024
Plan Review Stops For Project Z22080024
Review Stop AIPP ART IN PUBLIC PLACES
Rev No 2 Status P Date 07-11-2023 Cont ID  
Sent By swelter Date 07-11-2023 Time 12:32 Rev Time 0.00
Received By swelter Date   Time   Sent To  
Notes
2023-07-11 12:34:26APPLICANT SUBMITTED ART ASSESSMENT APPLICATION -
 SELECTED OPTION 2 - CONTRIBUTION ON 7.10.23

Review Stop AIPP ART IN PUBLIC PLACES
Rev No 1 Status F Date 06-14-2023 Cont ID  
Sent By swelter Date 06-14-2023 Time 14:08 Rev Time 0.00
Received By swelter Date 06-14-2023 Time 14:45 Sent To  
Notes
2023-06-14 14:45:40 
  
 DEVELOPMENT SUBJECT TO PUBLIC ART REQUIREMENT.
 ART ASSESSMENT APPLICATION DUE NOW
 ART ASSESSMENT FEES AT 1% OF THE TOTAL CONSTRUCTION
 COSTS MUST BE SUBMITTED BEFORE OR DURING BUILDING
 PERMIT FEES.
 CONTACT SYBILLE WELTER, ADMINISTRATOR OF PUBLIC ART AND
 CULTURE
 [email protected]
 561.822.1521
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 06-22-2023 Cont ID  
Sent By rbrown Date 06-22-2023 Time 12:42 Rev Time 0.00
Received By rbrown Date 06-22-2023 Time 12:42 Sent To  
Notes
2023-06-22 12:43:07DEVELOPMENT SERVICES DEPARTMENT, BUILDING DIVISION,
 COMMENTS:
  
 1. THIS REVIEW IS A CURSORY REVIEW AS IT RELATES TO THE
 SITE. IT IS NOT A REVIEW FOR FULL COMPLIANCE WITH
 FLORIDA BUILDING CODE. THE FOLLOWING COMMENTS ARE TO BE
 ADDRESSED FOR THE BUILDING PERMIT APPLICATION.
  
 2. DEMOLITION OF THE EXISTING BUILDING. AN ASBESTOS
 SURVEY SHALL BE PERFORMED AND AN ASBESTOS ABATEMENT
 REPORT SUBMITTED TO THE HEALTH DEPARTMENT PALM BEACH
 COUNTY OFFICE. CONTACT ALEX ORTEGA AT (561) 837-5963,
 OR BY EMAIL: [email protected]
  
 3. FLOOD ZONE. ACCORDING TO THE ADOPTED FLOOD INSURANCE
 RATE MAPS (FIRMS), THE PROPOSED BUILDING IS IN FLOOD
 ZONE AE, WITH A BASE FLOOD ELEVATION OF 12.7 FT NAVD.
 THE FIRST FLOOR OF THE BUILDING AND ALL ASSOCIATED
 MECHANICAL EQUIPMENT (CHILLERS, GENERATORS ETC.) SHALL
 BE 24 INCHES (FREEBOARD) ABOVE THE BASE FLOOD
 ELEVATION.
  
 4. BUILDING SIZE. WHEN SUBMITTED FOR BUILDING PERMIT,
 THE PLANS SHALL SHOW THAT THE TYPE OF CONSTRUCTION FOR
 THE BUILDINGS WILL BE IN ACCORDANCE WITH THE HEIGHT,
 AREA AND OCCUPANCY LIMITATIONS IN CHAPTER 5 OF THE
 FLORIDA BUILDING CODE.
  
 5. BUILDING LOCATION RELATIVE TO THE PROPERTY LINE AND
 OTHER STRUCTURES. WHEN SUBMITTED FOR BUILDING PERMIT,
 COMPLIANCE WITH ALL BUILDING SEPARATION, PERCENTAGE OF
 OPENINGS AND OPENING PROTECTIVE REQUIREMENTS OF
 CHAPTERS 6 AND 7 OF THE FLORIDA BUILDING CODE SHALL BE
 VERIFIED.
  
 6. SEPARATE PERMITS REQUIRED. ALL APPLICABLE PERMITS
 AND SUB-PERMITS MUST BE OBTAINED BEFORE COMMENCING THE
 WORK. SEPARATE PERMITS, PLANS AND FEES, ARE REQUIRED
 FOR SIGNS, SWIMMING POOLS AND SPAS, GAS SYSTEMS,
 GENERATORS, FIRE ALARM SYSTEMS, FIRE SPRINKLER AND
 OTHER FIRE SUPPRESSION SYSTEMS, GREASE INTERCEPTORS,
 SITE LIGHTING, SITE LANDSCAPE, SITE IRRIGATION, ETC.
  
 7. CONTRACTOR VEHICLE PARKING. PROPERTY OWNER AND
 CONTRACTOR SHALL MAKE ARRANGEMENTS FOR PARKING OF
 CONTRACTOR VEHICLES TO MINIMIZE THE IMPACT ON ALL
 NEIGHBORING PROPERTIES.
  
 8. PROTECTION OF NEIGHBORING PROPERTY. PROPERTY OWNER
 AND CONTRACTOR SHALL PROTECT ALL NEIGHBORING PROPERTY,
 INCLUDING VEHICLES, FROM DAMAGE OR DIRT CAUSED BY THE
 CONSTRUCTION, AND SHALL NOTIFY THE OCCUPANTS OF
 NEIGHBORING PROPERTIES ABOUT ALL STAGES OF CONSTRUCTION
 THAT MAY AFFECT THE USE OF THEIR PROPERTY.
  
 9. BUILDING ADDRESS. EACH SEPARATE BUILDING, AND UNIT
 WITH AN INDEPENDENT ENTRANCE FROM THE STREET, SHALL
 HAVE A SEPARATE ADDRESS ASSIGNED BASED ON THE LOCATION
 OF THE BUILDING ENTRANCE. FOR STREET ADDRESSING,
 CONTACT CAROLINE PUELL, ADDRESSING COORDINATOR, AT
 (561) 805 6659, OR BY EMAIL: [email protected]
  
 10. ART IN PUBLIC PLACES. THIS PROJECT WILL BE SUBJECT
 TO ART LIFE ASSESSMENT UNDER THE CITY OF WEST PALM
 BEACH ART IN PUBLIC PLACES (AIPP) PROGRAM. FOR ADVICE
 ON THE PROVISION OF PUBLIC ARTWORK IN LIEU OF THE AIPP
 ASSESSMENT, CONTACT SYBILLE WELTER, ART IN PUBLIC
 PLACES COORDINATOR, AT (561) 822-1521, OR BY EMAIL:
 [email protected]
  
 ROBERT BROWN
 BUILDING OFFICIAL
 TEL: 561 805 6652
 EMAIL: [email protected]
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 09-07-2022 Cont ID  
Sent By rbrown Date 09-07-2022 Time 16:19 Rev Time 0.00
Received By rbrown Date 09-07-2022 Time 16:13 Sent To  
Notes
2022-09-07 16:29:32DEVELOPMENT SERVICES DEPARTMENT, BUILDING DIVISION,
 COMMENTS:
  
 1. THIS REVIEW IS A CURSORY REVIEW AS IT RELATES TO THE
 SITE. IT IS NOT A REVIEW FOR FULL COMPLIANCE WITH
 FLORIDA BUILDING CODE. THE FOLLOWING COMMENTS ARE TO BE
 ADDRESSED FOR THE BUILDING PERMIT APPLICATION.
  
 2. DEMOLITION OF THE EXISTING BUILDING. AN ASBESTOS
 SURVEY SHALL BE PERFORMED AND AN ASBESTOS ABATEMENT
 REPORT SUBMITTED TO THE HEALTH DEPARTMENT PALM BEACH
 COUNTY OFFICE. CONTACT ALEX ORTEGA AT (561) 837-5963,
 OR BY EMAIL: [email protected]
  
 3. FLOOD ZONE. ACCORDING TO THE ADOPTED FLOOD INSURANCE
 RATE MAPS (FIRMS), THE PROPOSED BUILDING IS IN FLOOD
 ZONE AE, WITH A BASE FLOOD ELEVATION OF 12.7 FT NAVD.
 THE FIRST FLOOR OF THE BUILDING AND ALL ASSOCIATED
 MECHANICAL EQUIPMENT (CHILLERS, GENERATORS ETC.) SHALL
 BE 24 INCHES (FREEBOARD) ABOVE THE BASE FLOOD
 ELEVATION.
  
 4. LOCATION OF ACCESSIBLE PARKING SPACES. THE PROPOSED
 ACCESSIBLE PARKIKNG SPACE MUST BE MOVED CLOSER TO THE
 OFFICE. SITE PLAN, SHEET A3.0, SHOWS REGULAR PARKING
 SPACES THAT ARE CLOSER TO THE OFFICE THAN THE LOCATION
 OF THE PROPOSED ACCESSIBLE PARKING SPACE. PER SECTION
 208.3 OF FLORIDA ACCESSIBILITY CODE, ACCESSIBLE PARKING
 SPACES ARE TO BE LOCATED ON THE SHORTEST POSSIBLE ROUTE
 OF TRAVEL FROM ADJACENT PARKING TO AN ACCESSIBLE
 ENTRANCE. THE DESIGN OF ACCESSIBLE PARKING SPACES SHALL
 COMPLY WITH SECTION 502 OF FLORIDA ACCESSIBILITY CODE
  
 5. ELECTRIC VEHICLE CHARGING STATION. SITE PLAN, SHEET
 SP-1, SHOWS PROPOSED ELECTRIC VEHICLE (EV) CHARGING
 STATIONS. IF EV CHARGING STATIONS ARE BEING PROVIDED AT
 LEAST 1 IN 25 MUST BE POSITIONED AT AN ACCESSIBLE
 PARKING SPACE REQUIREMENTS. PLACING ONE OF THE EV
 CHARGING STATIONS AT THE ONE REQUIRED ACCESSIBLE
 PARKING SPACE WILL MEET THIS REQUIREMENT.
  
 6. BUILDING SIZE. WHEN SUBMITTED FOR BUILDING PERMIT,
 THE PLANS SHALL SHOW THAT THE TYPE OF CONSTRUCTION FOR
 THE BUILDINGS WILL BE IN ACCORDANCE WITH THE HEIGHT,
 AREA AND OCCUPANCY LIMITATIONS IN CHAPTER 5 OF THE
 FLORIDA BUILDING CODE.
  
 7. BUILDING LOCATION RELATIVE TO THE PROPERTY LINE AND
 OTHER STRUCTURES. WHEN SUBMITTED FOR BUILDING PERMIT,
 COMPLIANCE WITH ALL BUILDING SEPARATION, PERCENTAGE OF
 OPENINGS AND OPENING PROTECTIVE REQUIREMENTS OF
 CHAPTERS 6 AND 7 OF THE FLORIDA BUILDING CODE SHALL BE
 VERIFIED.
  
 8. SEPARATE PERMITS REQUIRED. ALL APPLICABLE PERMITS
 AND SUB-PERMITS MUST BE OBTAINED BEFORE COMMENCING THE
 WORK. SEPARATE PERMITS, PLANS AND FEES, ARE REQUIRED
 FOR SIGNS, SWIMMING POOLS AND SPAS, GAS SYSTEMS,
 GENERATORS, FIRE ALARM SYSTEMS, FIRE SPRINKLER AND
 OTHER FIRE SUPPRESSION SYSTEMS, GREASE INTERCEPTORS,
 SITE LIGHTING, SITE LANDSCAPE, SITE IRRIGATION, ETC.
  
 9. CONTRACTOR VEHICLE PARKING. PROPERTY OWNER AND
 CONTRACTOR SHALL MAKE ARRANGEMENTS FOR PARKING OF
 CONTRACTOR VEHICLES TO MINIMIZE THE IMPACT ON ALL
 NEIGHBORING PROPERTIES.
  
 10. PROTECTION OF NEIGHBORING PROPERTY. PROPERTY OWNER
 AND CONTRACTOR SHALL PROTECT ALL NEIGHBORING PROPERTY,
 INCLUDING VEHICLES, FROM DAMAGE OR DIRT CAUSED BY THE
 CONSTRUCTION, AND SHALL NOTIFY THE OCCUPANTS OF
 NEIGHBORING PROPERTIES ABOUT ALL STAGES OF CONSTRUCTION
 THAT MAY AFFECT THE USE OF THEIR PROPERTY.
  
 11. BUILDING ADDRESS. EACH SEPARATE BUILDING, AND UNIT
 WITH AN INDEPENDENT ENTRANCE FROM THE STREET, SHALL
 HAVE A SEPARATE ADDRESS ASSIGNED BASED ON THE LOCATION
 OF THE BUILDING ENTRANCE. FOR STREET ADDRESSING,
 CONTACT CAROLINE PUELL, ADDRESSING COORDINATOR, AT
 (561) 805 6659, OR BY EMAIL: [email protected]
  
 12. ART IN PUBLIC PLACES. THIS PROJECT WILL BE SUBJECT
 TO ART LIFE ASSESSMENT UNDER THE CITY OF WEST PALM
 BEACH ART IN PUBLIC PLACES (AIPP) PROGRAM. FOR ADVICE
 ON THE PROVISION OF PUBLIC ARTWORK IN LIEU OF THE AIPP
 ASSESSMENT, CONTACT SYBILLE WELTER, ART IN PUBLIC
 PLACES COORDINATOR, AT (561) 822-1521, OR BY EMAIL:
 [email protected]
  
 ROBERT BROWN
 BUILDING OFFICIAL
 TEL: 561 805 6652
 EMAIL: [email protected]
  

Review Stop ENG - PPRC ENGINEERING - PPRC
Rev No 3 Status P Date 03-13-2023 Cont ID  
Sent By rrossano Date 03-13-2023 Time   Rev Time 0.00
Received By rrossano Date 03-13-2023 Time   Sent To  
Notes
2023-03-13 18:12:49RESUBMIT CCTV AS DOWNLOAD LINK WITH MISSING ASSOCIATED
 CCTV REPORT TO [email protected] AND CC
 [email protected]; INCLUDE PROJECT Z22080024.
  
 * CCTV & REPORT RECVD 3.23.23

Review Stop ENG - PPRC ENGINEERING - PPRC
Rev No 2 Status F Date 01-19-2023 Cont ID  
Sent By rrossano Date 01-19-2023 Time   Rev Time 0.00
Received By rrossano Date 01-19-2023 Time   Sent To  
Notes
2023-01-19 12:38:11Z22080024 - 2500 N FLORIDA MANGO - REZONING SELF
 STORAGE 1.19.2023 RESUB
 COMMENTS FOR SITE PLAN SUBMITTAL FROM RICK ROSSANO, SR.
 PROJECT COORDINATOR, ENGINEERING SERVICES AT
 561-494-1098 [email protected]
  
 AWAITING PROVISION OF CCTV VIDEO OF EXISTING SANITARY
 SEWER AND STORMWATER INFRASTRUCTURE ALONG ENTIRE
 PROJECT FRONTAGE (CONDITION OF SITE PLAN APPROVAL).

Review Stop ENG - PPRC ENGINEERING - PPRC
Rev No 1 Status F Date 08-23-2022 Cont ID  
Sent By rrossano Date 08-23-2022 Time   Rev Time  
Received By rrossano Date 08-23-2022 Time   Sent To  
Notes
2022-08-23 14:37:33COMMENTS FOR SITE PLAN SUBMITTAL FROM RICK ROSSANO, SR.
 PROJECT COORDINATOR, ENGINEERING SERVICES AT
 561-494-1098 [email protected]
 GENERAL:
 O PLEASE RESPOND TO ALL COMMENTS IN WRITING, AND
 INCLUDE PROJECT NAME, ADDRESS AND PERMIT NUMBER
 (Z-XXXXXXXX).
 O THE CITY OF WEST PALM BEACH HAS A NUMBER OF
 REGULATIONS AND PERMIT REQUIREMENTS WHICH DIRECTLY
 AFFECT THE DEVELOPMENT AND INSTALLATION OF WATER AND
 WASTEWATER UTILITIES WITHIN THE CITY. PLEASE SEE
 DEVELOPMENT PERMIT SUBMITTAL REQUIREMENTS AT THE LINK
 BELOW:
 A. HTTP://WPB.ORG/CMSPAGES/GETAMAZONFILE.ASPX?PATH=~\WP
 B_WEBSITE\MEDIA\ENGINEERING\DEVELOPMENT-APPLICATION-FUL
 L-PACKAGE_2016.PDF&HASH=7BD4DD7EB6115181D8C5977BCC02A97
 B1960045731D3658206F27451722716EF
 B. THIS AND OTHER RELATED ENGINEERING DOCUMENTS CAN BE
 FOUND HERE:
 HTTP://WPB.ORG/DEPARTMENTS/ENGINEERING-PUBLIC-WORKS/FOR
 MS,-PERMITS-APPLICATIONS
 C. ALSO SEE: CODE OF ORDINANCES, CITY OF WEST PALM
 BEACH, FLORIDA, CODIFIED THROUGH ORD. NO. 4183-08,
 ADOPTED SEPT. 22, 2008. (SUPPLEMENT NO. 18)
 CHAPTER 90 UTILITIES, ARTICLE I. IN GENERAL,
 SEC. 90-7. POLICY REGARDING EXTENSION OF WATER OR SEWER
 SERVICE FACILITIES OF THE CITY.
 THE WATER AND WASTEWATER SERVICE AGREEMENTS AND THE
 CONSTRUCTION PERMITS ADDRESS RESERVATION OF CAPACITY
 BASED ON USAGE, METER SIZE AND FEES, DESIGN STANDARDS,
 BACKFLOW PREVENTION, FIRE SERVICE AND IRRIGATION.
 O AS OF DECEMBER 20, 2015, THE CITY OF WEST PALM BEACH
 CROSS-CONNECTION CONTROL MANUAL HAS BEEN REVISED,
 STATING "ALL BACKFLOW DEVICES MUST BE LEAD-FREE". FOR
 MORE INFORMATION, REFER TO THE LINK BELOW:
 A. HTTP://WPB.ORG/DEPARTMENTS/PUBLIC-UTILITIES/FORMS-PU
 BLICATIONS/BACKFLOW-CROSS-CONNECTION- CONTROL-MANUAL
 O PLEASE SUBMIT A FORMAL AS-BUILT REQUEST FOR ALL CITY
 OF WEST PALM BEACH-OWNED UTILITIES WITHIN THE PUBLIC
 RIGHT OF WAY FOR THE ENTIRE EXTENT OF THE LIMITS OF
 YOUR PROJECT. IDENTIFY TYPE OF UTILITY, LOCATION, PIPE
 MATERIAL, AGE AND SIZE. PLEASE CONTACT JANICE TARBILL
 IN THE WPB ENGINEERING SERVICES DEPARTMENT AT
 [email protected] OR 561-494-1079 FOR FURTHER
 ASSISTANCE. NOTE THAT FIELD RECORDS ARE FOR INFORMATION
 ONLY. FIELD VERIFY UTILITY LOCATIONS USING FIELD
 SURVEY, POT-HOLING, SOFT DIGS ETC.
 O PROVIDE EXISTING AND PROPOSED PERVIOUS AND IMPERVIOUS
 DATA.
  
 BACKFLOW ASSEMBLY AND METERS:
 O SHOW AND LABEL ANY EXISTING OR PROPOSED WATER
 SERVICES AND WATER METERS, ALONG WITH WHAT IS HAPPENING
 TO THEM.
 O SHOW EXISTING AND PROPOSED DEDICATED UTILITY
 EASEMENTS TO ALLOW ACCESS FOR CITY PERSONNEL TO
 PROPOSED UTILITY WATER METERS. VERIFY THAT THERE ARE NO
 STRUCTURES WITHIN EASEMENT.
 O PROVIDE ENLARGED VIEW ON PLANS OF PROPOSED LOCATION
 OF WATER METER AND BACKFLOW
 PREVENTION.
 O BACKFLOWS SHALL BE INSTALLED ON PRIVATE PROPERTY
 OUTSIDE OF EASEMENTS AND RIGHTS OF WAY. DOMESTIC WATER
 METERS SHALL BE INSTALLED IMMEDIATELY ADJACENT TO
 PROPERTY LINE. 3 INCH AND LARGER WATER METERS SHALL BE
 INSTALLED ABOVE-GROUND ONLY.
 O CALLOUT DOMESTIC BACKFLOW PREVENTER AS RPPA (MAKE
 NOTE USC APPROVED) AND FIRE BACKFLOW PREVENTER AS DCDA.
  
 WATER/WASTEWATER PLAN:
 O PROVIDE VERTICAL DATUM AND DATUM CONVERSION
 INFORMATION (NAVD 1988 AND NGVD 1929).
 O SHOW PROJECT ADDRESS ON ALL PLAN SHEETS.
 O PROVIDE LEGEND ON ALL PLAN SHEETS TO INCLUDE
 STREETLIGHT, SIGN POSTS, TRANSFORMER BOXES ETC.
 O PLANS SHALL SHOW EXISTING AND PROPOSED LOCATIONS AND
 DIMENSIONS OF ALL WATER, STORMWATER, AND SANITARY AND
 SEWER LINES AND CLEANOUTS, INCLUDING STUBS TO EACH
 PROPERTY LINE FOR WATER AND SANITARY SEWERS, THE MAKE
 AND MODEL OF ALL VALVES, POTABLE AND IRRIGATION METERS,
 BACKFLOWS, FIRE HYDRANTS AND FDCS, AND OTHER DEVICES TO
 BE INSTALLED ON THE SYSTEM, CATCH BASINS, CULVERTS,
 DITCHES INCLUDING GRADES, PIPES SIZES, MATERIALS,
 ELEVATIONS, ASSUMPTIONS, CALCULATIONS, INVERT
 ELEVATIONS FOR ALL INLETS AND MANHOLES AND PROFILES OF
 SANITARY SEWER LINES.
 O GATE VALVE BOXES SHALL NOT BE INSTALLED IN CURB OR
 SIDEWALK. ALL AVAILABLE ELEVATION SHALL BE SHOWN ON THE
 PROFILE VIEW.
 O DIRECTION OF FLOW SHALL BE SHOWN ON PLAN VIEW ON PLAN
 VIEW FOR ALL SANITARY AND STORM SEWERS.
 O SHOW SLOPE % ON ALL SANITARY LINES AND CALL OUT
 MATERIAL.
 O PLAN VIEW SHALL SHOW ALL EXISTING AND PROPOSED
 UNDERGROUND UTILITY LAYOUT, INCLUDING FIBER OPTIC,
 ELECTRIC, GAS, AND CABLEVISION & TELECOMMUNICATION
 FACILITIES INCLUDING PIPE SIZE AND MATERIAL LOCATED IN
 THE RIGHT-OF-WAY.
 O PROVIDE PROFILE AND CLEARANCES BETWEEN WATER, SEWER
 AND STORM LINES PER CITY OF WEST PALM BEACH STANDARD
 DETAIL GN-2 SERIES, AT ALL UTILITY CROSSINGS. PLEASE
 INCLUDE FIBER OPTIC, ELECTRIC, GAS, AND CABLEVISION &
 TELECOMMUNICATION FACILITIES INCLUDING PIPE SIZE AND
 MATERIAL LOCATED IN THE RIGHT-OF-WAY.
 O SUBMIT COMPLETED LOS ANALYSIS SUMMARY TABLE DIRECTLY
 TO ENGINEERING (SHEET 33 OF CITY OF WPB DEVELOPMENT
 APPLICATION). PROVIDE CALCULATIONS ON PLANS OF EXISTING
 AND PROPOSED DEMANDS FOR WATER & SEWER (AVERAGE,
 MAXIMUM AND PEAK) AND FIRE FLOW DEMANDS. CALCULATIONS
 SHALL BE PER FAC 64E-6 FOR SEWER AND PER FAC 64-E.008
 FOR WATER.
 O PROVIDE FIRE FLOW TEST DATA.
 O PROVIDE CCTV VIDEO OF EXISTING SANITARY SEWER AND
 STORMWATER INFRASTRUCTURE ALONG ENTIRE PROJECT FRONTAGE
 (CONDITION OF SITE PLAN APPROVAL).
 O CUT AND CAP UTILITIES NOT IN USE AND REMOVE ANY
 ABANDONED UTILITY LINES LARGER THAN 2 INCHES FROM CITY
 ROW.
 O WHEN PROPOSED, WATER MAINS IN CITY RIGHT OF WAY SHALL
 BE MADE OF DUCTILE IRON PIPE (NOT PVC) AND SPECIFY
 PROPOSED LENGTH IN FEET.
 O CHECK TO SEE IF FDEP FORMS FOR PROPOSED SANITARY
 SEWER ARE REQUIRED.
 O PROVIDE CLEANOUTS FOR PROPOSED SANITARY LINE ONSITE
 JUST INSIDE PROPERTY LINE, AT JOINTS AND EVERY 75 FEET.
 O ADD NOTE TO PLANS SPECIFYING CITY?S DOWNSTREAM LIFT
 STATION NUMBER.
 O PROVIDE ONSITE CLEANOUTS NEAR PROPERTY LINE FOR
 PROPOSED SANITARY LATERALS.
 O LABEL WATER LINES AS PRIVATE WHERE APPLICABLE.
 O PLEASE SHOW AND LABEL EXISTING AND PROPOSED GREASE
 TRAPS (IF ANY).
 O PER CITY STANDARDS MAINTAIN MINIMUM DISTANCE BETWEEN
 OUTSIDE DIAMETER OF CITY PIPE AND ROOT BARRIER.
  
 FORMAL ENGINEERING REVIEW:
 O FOR FORMAL ENGINEERING SUBMITTAL, SFWMD ERP AND NPDES
 NOI REQUIREMENTS WILL BE ENFORCED.
 - AN NOI IS REQUIRED FOR PROJECTS THAT:
 - 1) DISTURB ONE OF MORE ACRES OF LAND OR DISTURB LESS
 THAN ON ACRE OF LAND BUT ARE PART OF A COMMON PLAN OF
 DEVELOPMENT OR SALE;
 - 2) DISCHARGE STORMWATER TO SURFACE WATERS OF THE
 STATE OR TO SURFACE WATERS OF THE STATE THROUGH A
 MUNICIPAL SEPARATE STORM SEWER SYSTEM (MS4).
 - THE SFWMD ERP CAN BE OBTAINED THROUGH A 10-2 SELF
 CERTIFICATION THROUGH FDEP OR AN ERP APPLICATION
 THROUGH SFWMD. EITHER WAY, THE DEVELOPER/ENGINEER SHALL
 SUBMIT A COPY OF THE ERP PERMIT OR FDEP ACKNOWLEDGEMENT
 OF THE 10-2 CERTIFICATION.
 O FOR FORMAL ENGINEERING SUBMITTAL, PLEASE PROVIDE
 EASEMENT FOR PLACEMENT OF PROPOSED WATER METERS.
 O FOR FORMAL ENGINEERING SUBMITTAL, PROVIDE PROFILES OF
 WATER AND SEWER AND SHOW ANY CROSSINGS/CONFLICTS.
 O FOR FORMAL ENGINEERING SUBMITTAL, WHEN SUBMITTING
 APPROVED MATERIALS LIST, PLEASE PROVIDE MATERIAL/CUT
 SHEETS FOR ALL PROPOSED BACKFLOW DEVICES SHOWING
 SPECIFIC MODEL NUMBER AND SPECIFYING USC APPROVED
 LEAD-FREE DESIGN.
 O FOR FORMAL ENGINEERING SUBMITTAL, IF SANITARY LINES
 ARE PROPOSED IN ROW PLEASE SHOW ADJACENT SANITARY
 LATERAL LOCATIONS AND SHOW ADDRESSES OF ADJACENT
 PARCELS.
 O FOR FORMAL ENGINEERING SUBMITTAL, IF WATER LINES ARE
 BEING REPLACED IN ROW, SHOW ADJACENT PARCEL ADDRESSES.
 O FOR FORMAL ENGINEERING SUBMITTAL, ADD NOTE TO PROVIDE
 50 FT. PAVEMENT RESTORATION TRANSITION ON EACH SIDE OF
 PROPOSED TRENCH IN CITY MAINTAINED ROADWAY AREAS PER
 CITY OF WPB STANDARD DETAIL GC-8.
 O FOR FORMAL ENGINEERING SUBMITTAL, PLEASE PROVIDE
 CALCULATIONS OF PERVIOUS AND IMPERVIOUS AREAS FOR
 PROPOSED IMPROVED AREAS.
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 4 Status P Date 05-22-2023 Cont ID  
Sent By pleduc Date 05-22-2023 Time   Rev Time 0.00
Received By pleduc Date 05-22-2023 Time 10:19 Sent To  
Notes
2023-05-22 10:19:514TH REVIEW RESPONSE
  
 AFTER A REVIEW OF THE PPRC RESPONSE PACKET FOR THIS
 PROJECT, THE PREVIOUSLY SUBMITTED FIRE PREVENTION
 BUREAU COMMENTS APPEAR TO HAVE BEEN ADDRESSED.
  
 HOWEVER, THE BUREAU'S APPROVAL OF THIS SUBMITTED
 PROJECT DOES NOT CONSTITUTE ITS FINAL REVIEW OR
 APPROVAL.
  
 THE BUREAU SHALL REVIEW ALL SUBMITTED BUILDING PLANS AT
 THE APPROPRIATE TIME AND IN ACCORDANCE WITH THE
 REQUIREMENTS OF ALL APPLICABLE CODES AND STANDARDS.
  
 PETER LEDUC
 FIRE MARSHAL
 WEST PALM BEACH FIRE DEPARTMENT
 561-804-4709
 [email protected]

Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status P Date 03-14-2023 Cont ID  
Sent By pleduc Date 03-14-2023 Time   Rev Time 0.00
Received By pleduc Date 03-14-2023 Time 13:11 Sent To  
Notes
2023-03-14 13:12:053RD REVIEW RESPONSE
  
 AFTER A REVIEW OF THE PPRC RESPONSE PACKET FOR THIS
 PROJECT, THE PREVIOUSLY SUBMITTED FIRE PREVENTION
 BUREAU COMMENTS APPEAR TO HAVE BEEN ADDRESSED.
  
 HOWEVER, THE BUREAU'S APPROVAL OF THIS SUBMITTED
 PROJECT DOES NOT CONSTITUTE ITS FINAL REVIEW OR
 APPROVAL.
  
 THE BUREAU SHALL REVIEW ALL SUBMITTED BUILDING PLANS AT
 THE APPROPRIATE TIME AND IN ACCORDANCE WITH THE
 REQUIREMENTS OF ALL APPLICABLE CODES AND STANDARDS.
  
 PETER LEDUC
 FIRE MARSHAL
 WEST PALM BEACH FIRE DEPARTMENT
 561-804-4709
 [email protected]
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 01-20-2023 Cont ID  
Sent By pleduc Date 01-20-2023 Time 12:37 Rev Time 0.00
Received By pleduc Date 01-20-2023 Time 12:36 Sent To  
Notes
2023-01-20 12:37:282ND REVIEW RESPONSE
  
 AFTER A REVIEW OF THE PPRC RESPONSE PACKET FOR THIS
 PROJECT, THE PREVIOUSLY SUBMITTED FIRE PREVENTION
 BUREAU COMMENTS APPEAR TO HAVE BEEN ADDRESSED.
  
 HOWEVER, THE BUREAU'S APPROVAL OF THIS SUBMITTED
 PROJECT DOES NOT CONSTITUTE ITS FINAL REVIEW OR
 APPROVAL.
  
 THE BUREAU SHALL REVIEW ALL SUBMITTED BUILDING PLANS AT
 THE APPROPRIATE TIME AND IN ACCORDANCE WITH THE
 REQUIREMENTS OF ALL APPLICABLE CODES AND STANDARDS.
  
 PETER LEDUC
 FIRE MARSHAL
 WEST PALM BEACH FIRE DEPARTMENT
 561-804-4709
 [email protected]
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 08-29-2022 Cont ID  
Sent By pleduc Date 08-29-2022 Time   Rev Time 0.00
Received By pleduc Date 08-29-2022 Time 14:51 Sent To  
Notes
2022-08-29 14:53:05THE FOLLOWING COMMENTS WERE SUBMITTED BY PETER LEDUC,
 FIRE MARSHAL, BUREAU OF FIRE PREVENTION, WEST PALM
 BEACH FIRE DEPARTMENT.
  
 THIS REVIEW CAN ONLY BE CONSIDERED PRELIMINARY AS THE
 DRAWINGS THAT WERE REVIEWED WERE NOT COMPLETE.
 ADDITIONAL COMMENTS CAN BE EXPECTED WHEN FULL DRAWINGS
 ARE SUBMITTED FOR PERMIT.
  
 THE FIRE PREVENTION BUREAU HAS NO OBJECTIONS TO THE
 PROPOSED PROJECT. THE FOLLOWING COMMENTS ARE INTENDED
 TO PROVIDE GUIDANCE FOR BUILDING PLAN SUBMITTAL.
  
 1. CONSTRUCTION, DEMOLITION, AND RENOVATION TO COMPLY
 WITH NFPA 241. EXTRA ATTENTION SHALL BE GIVEN TO THE
 PERMITTING AND LOCATION OF CONSTRUCTION TRAILERS. A
 PERMIT IS REQUIRED FOR ANY CONSTRUCTION TRAILER RELATED
 TO THIS PROJECT. SEPARATION DISTANCES FROM MAIN
 STRUCTURES AS WELL AS OTHER TRAILERS SHALL BE CLOSELY
 MONITORED FOR THE REQUIREMENTS OF FIRE SPRINKLER
 PROTECTION.
  
 2. SITE ACCESS AND EXIT POINTS ARE TO BE CLEARLY
 IDENTIFIED AND MAINTAINED FOR EMERGENCY VEHICLES DURING
 ALL CONSTRUCTION ACTIVITIES.
  
 3. THE BUILDING ADDRESS SHALL BE CLEARLY VISIBLE FROM
 ALL ACCESS ROADWAYS, INCLUDING DURING CONSTRUCTION.
 ADDRESS NUMBERS SHALL CONTRAST WITH THEIR BACKGROUND
 AND SHALL NOT BE LESS THAN SIX (6) INCHES IN HEIGHT
 WITH A ONE (1) INCH STROKE FOR ALL BUILDINGS.
  
 4. DURING CONSTRUCTION, TRASH AND DEBRIS IS TO BE
 REMOVED FROM THE SITE DAILY OR MORE OFTEN TO REDUCE THE
 ACCUMULATION OF POTENTIAL LIFE AND FIRE SAFETY HAZARDS.
  
 5. THE CONSTRUCTION OF THE BUILDING(S) SHALL COMPLY
 WITH THE 7TH EDITION OF THE FLORIDA FIRE PREVENTION
 CODE, INCLUDING NFPA 1 & 101, AND ALL ASSOCIATED FIRE
 CODES.
  
 6. FOR PLAN REVIEW SUBMITTAL, PLEASE INCLUDE THE
 OCCUPANCY TYPE PER THE FLORIDA FIRE PREVENTION CODE.
  
 7. FOR PLAN REVIEW SUBMITTAL, PLEASE ENSURE THAT A FIRE
 LOAD CALCULATION IS INCLUDED, AND THAT ADEQUATE WATER
 SUPPLY IS EXISTING OR WILL BE PROVIDED.
  
 8. ALL EXISTING AND NEW FIRE HYDRANTS PLANNED FOR THIS
 DEVELOPMENT SHALL BE CLEARLY INDICATED AND IDENTIFIED
 ON THE PLAN AND CLOSELY COORDINATED WITH THE BUREAU OF
 FIRE PREVENTION.
  
 THE PROPOSED LOCATION OF THE FIRE HYDRANT AND FDC SHALL
 BE WITHIN 100' OF EACH OTHER AND CLOSELY COORDINATED
 WITH THE BUREAU OF FIRE PREVENTION.
  
 9. PROVIDE FOR A FIRE SPRINKLER AND/OR FIRE ALARM PER
 THE APPLICABLE OCCUPANCY CODE. FOR ANY LIFE SAFETY
 ENGINEERED SYSTEM, I.E FIRE SPRINKLER AND FIRE ALARM,
 ENSURE THEY COMPLY WITH THE REQUIREMENTS OF F.A.C. 61G
 AND SUBMITTED WITH THE MASTER PERMIT.
  
 9A. THE LOCATION OF ANY APPLICABLE DDCV AND FIRE LINE
 LOCATIONS SHALL MEET AND BE INSTALLED PER THE
 REQUIREMENTS OF NFPA 24 AND SHALL BE COORDINATED WITH
 THE OFFICE OF FIRE MARSHAL, THE CITY'S ENGINEERS
 OFFICE, THE LANDSCAPE PLANNER, AND THE CITY'S PLANNING
 AND ZONING OFFICE.
  
 10. COMPLETE LIFE SAFETY PLANS FOR THE OCCUPANCY SHALL
 BE PROVIDED THAT ILLUSTRATE OCCUPANT LOADS, TRAVEL
 DISTANCES, EXIT SEPARATION DISTANCES, COMMON PATHS OF
 TRAVEL, DEAD-END CORRIDORS, EXIT SIGNS, EMERGENCY
 LIGHTING, EXITS LEADING TO A PUBLIC WAY, FIRE
 EXTINGUISHER LOCATIONS, AND ALL FIRE SAFETY FEATURES
 AND EQUIPMENT.
  
 11. IT IS HIGHLY RECOMMENDED (REQUIRED WITH FIRE
 SPRINKLER SYSTEM) THAT A KNOX BOX WITH KEYS FOR ENTRY
 DOOR LOCKS BE PROVIDED FOR 24 HOUR EMERGENCY ACCESS.
  
 12. ALL NEW ELEVATORS SHALL CONFORM TO THE FIRE
 FIGHTER?S EMERGENCY OPERATIONS REQUIREMENTS OF ASME
 A17.1/CSA B44, SAFETY CODE FOR ELEVATORS.
  
 ANY BUILDING THAT IS MORE THAN THREE STORIES HIGH OR IN
 WHICH THE VERTICAL DISTANCE BETWEEN THE BOTTOM TERMINAL
 LANDING AND THE TOP TERMINAL LANDING EXCEEDS 25 FEET
 MUST BE CONSTRUCTED TO CONTAIN AT LEAST ONE PASSENGER
 ELEVATOR THAT IS OPERATIONAL AND WILL ACCOMMODATE AN
 AMBULANCE STRETCHER 76 INCHES LONG AND 24 INCHES WIDE
 IN THE HORIZONTAL POSITION.
  
 13. TWO-WAY RADIO COMMUNICATIONS ENHANCEMENT SYSTEMS.
  
 NFPA 1, CHAPTER 11, BUILDING SERVICES; 11.10 TWO-WAY
 RADIO ENHANCEMENT SERVICES.
  
 11.10.1 IN ALL NEW AND EXISTING BUILDINGS, MINIMUM
 RADIO SIGNAL STRENGTH FOR FIRE DEPARTMENT
 COMMUNICATIONS SHALL BE MAINTAINED AT A LEVEL
 DETERMINED BY THE AHJ.
  
 CONTACT WILL NEED TO BE MADE TO MARK FILLA, PALM BEACH
 COUNTY PUBLIC SAFETY RADIO SYSTEMS MANAGER,
 [email protected], 561-233-0837; AS OUR RADIOS OPERATE
 ON THEIR SYSTEM FOR DETAILED RADIO FREQUENCY AND
 INSTALLATION INSTRUCTIONS.
  
  
 14. THE BUREAU'S APPROVAL OF THIS SUBMITTED PROJECT
 DOES NOT CONSTITUTE ITS FINAL REVIEW OR APPROVAL.
  
  
 15. THE BUREAU SHALL REVIEW ALL SUBMITTED BUILDING
 PLANS AT THE APPROPRIATE TIME AND IN ACCORDANCE WITH
 THE REQUIREMENTS OF ALL APPLICABLE CODES AND STANDARDS.
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]
  

Review Stop L LANDSCAPING
Rev No 4 Status F Date 06-12-2023 Cont ID  
Sent By kdefranc Date 06-12-2023 Time 11:11 Rev Time 0.00
Received By kdefranc Date 06-12-2023 Time 11:11 Sent To  
Notes
2023-06-12 11:10:55FROM: KEVIE DEFRANC, SENIOR PLANNER 561-822-1449
 PROJECT: TROPICANA SELF STORAGE Z22080024
 JUNE 12, 2023
 I HAVE REVIEWED THE ABOVE REFERENCED PETITION, AND
 PROVIDE THE FOLLOWING COMMENTS:
  
  
 1. SATISFIED. CORRECT THE TREE DISPOSITION PLAN TO SHOW
 TREES #7, 8, 9, 10, 11, AND 12 OFFSITE ON THE CHART.
  
 2. SATISFIED. PER SECTION 94-442(B)Q. SHOW TREES AND
 PALMS ON THE ADJACENT PROPERTIES WITHIN 10 FEET OF THE
 PROPERTY LINE AND PLACE BUFFER TREES ACCORDINGLY TO
 AVOID CANOPY CONFLICT.
  
 3. SATISFIED. WATER LINES SHOULD BE SHIFTED TO THE
 SOUTH TO AVOID CONFLICT WITH THE LANDSCAPE ISLAND AND
 TREE.
  
 4. PARTIALLY SATISFIED. SHEET LP-3 WITH EXHIBIT SHOWS
 THE PARKING AREA SURFACE CALCULATIONS, PARKING SPACE
 AREAS AND LANDSCAPE AREAS PROVIDED TO DEMONSTRATE
 COMPLIANCE WITH SECTIONS 94-443 (C)(3) AND (4). REFER
 TO FIGURE XIV-1, THE ACTUAL PROVIDED INTERIOR LANDSCAPE
 SQUARE FOOTAGE THAT CAN BE COUNTED MUST BE WITHIN THE
 EXTERIOR EDGE OF THE VEHICULAR USE AREA. LANDSCAPE
 BUFFERS AND AREAS OUTSIDE THE PERIMETER OF THE
 VEHICULAR USE AREA CANNOT BE COUNTED. LOADING SPACES
 MUST BE COUNTED IN THE OTHER VEHICULAR USE AREA.
 REVISE.
 1/31/23 OTHER VEHICULAR USE AREA SHOULD BE 97,377 SF
 PLUS 5,586 SQ FT = 102,963 SQ FT
 SO REQUIRED INTERIOR LANDSCAPE AREA SHOULD BE 140 SQ FT
 PLUS 4119 SQ FT = 4259 SQ FT
 CORRECT THIS ON SHEET LP-3.
 4/19/23 REFER TO ADDITIONAL COMMENT # 6 BELOW, WHICH
 HAS AN IMPACT ON THIS COMMENT AS WELL.
  
 5. SATISFIED. PROVIDE SCREENING HEDGE FOR THE BACKFLOW
 PREVENTERS.
  
 ADDITIONAL COMMENTS 1/31/23:
  
 6. NOT SATISFIED. THIS SITE AND LANDSCAPE PLAN IS BASED
 ON A PROPOSED CODE CHANGE FOR PARKING REQUIREMENTS, SO
 WILL NOT BE ABLE TO BE FINALIZED AND PASS THE REVIEW
 UNTIL THE PARKING MEETS THE CODE REQUIREMENT.
  
 7. SATISFIED. ADJUST THE PLANT LIST ON SHEET LP-2 SO
 THAT THE COLUMNS FOR WATER USAGE AND NATIVE LINE UP.
  
  
 CONDITIONS OF APPROVAL
 1. PRIOR TO THE REMOVAL OR RELOCATION OF ANY TREES ON
 THE PROPERTY, A TREE ALTERATION PERMIT SHALL BE
 SUBMITTED, REVIEWED AND APPROVED BY THE DEVELOPMENT
 SERVICES DEPARTMENT, PLANNING DIVISION.
  

Review Stop L LANDSCAPING
Rev No 3 Status F Date 04-19-2023 Cont ID  
Sent By kdefranc Date 04-19-2023 Time 11:55 Rev Time 0.00
Received By kdefranc Date 04-19-2023 Time 11:53 Sent To  
Notes
2023-04-19 11:54:35FROM: KEVIE DEFRANC, SENIOR PLANNER 561-822-1449
 PROJECT: TROPICANA SELF STORAGE Z22080024
 APRIL 19, 2023
 I HAVE REVIEWED THE ABOVE REFERENCED PETITION, AND
 PROVIDE THE FOLLOWING COMMENTS:
  
  
 1. SATISFIED. CORRECT THE TREE DISPOSITION PLAN TO SHOW
 TREES #7, 8, 9, 10, 11, AND 12 OFFSITE ON THE CHART.
  
 2. SATISFIED. PER SECTION 94-442(B)Q. SHOW TREES AND
 PALMS ON THE ADJACENT PROPERTIES WITHIN 10 FEET OF THE
 PROPERTY LINE AND PLACE BUFFER TREES ACCORDINGLY TO
 AVOID CANOPY CONFLICT.
  
 3. SATISFIED. WATER LINES SHOULD BE SHIFTED TO THE
 SOUTH TO AVOID CONFLICT WITH THE LANDSCAPE ISLAND AND
 TREE.
  
 4. PARTIALLY SATISFIED. SHEET LP-3 WITH EXHIBIT SHOWS
 THE PARKING AREA SURFACE CALCULATIONS, PARKING SPACE
 AREAS AND LANDSCAPE AREAS PROVIDED TO DEMONSTRATE
 COMPLIANCE WITH SECTIONS 94-443 (C)(3) AND (4). REFER
 TO FIGURE XIV-1, THE ACTUAL PROVIDED INTERIOR LANDSCAPE
 SQUARE FOOTAGE THAT CAN BE COUNTED MUST BE WITHIN THE
 EXTERIOR EDGE OF THE VEHICULAR USE AREA. LANDSCAPE
 BUFFERS AND AREAS OUTSIDE THE PERIMETER OF THE
 VEHICULAR USE AREA CANNOT BE COUNTED. LOADING SPACES
 MUST BE COUNTED IN THE OTHER VEHICULAR USE AREA.
 REVISE.
 1/31/23 OTHER VEHICULAR USE AREA SHOULD BE 97,377 SF
 PLUS 5,586 SQ FT = 102,963 SQ FT
 SO REQUIRED INTERIOR LANDSCAPE AREA SHOULD BE 140 SQ FT
 PLUS 4119 SQ FT = 4259 SQ FT
 CORRECT THIS ON SHEET LP-3.
 4/19/23 REFER TO ADDITIONAL COMMENT # 6 BELOW, WHICH
 HAS AN IMPACT ON THIS COMMENT AS WELL.
  
 5. SATISFIED. PROVIDE SCREENING HEDGE FOR THE BACKFLOW
 PREVENTERS.
  
 ADDITIONAL COMMENTS 1/31/23:
  
 6. NOT SATISFIED. THIS SITE AND LANDSCAPE PLAN IS BASED
 ON A PROPOSED CODE CHANGE FOR PARKING REQUIREMENTS, SO
 WILL NOT BE ABLE TO BE FINALIZED AND PASS THE REVIEW
 UNTIL THE PARKING MEETS THE CODE REQUIREMENT.
  
 7. SATISFIED. ADJUST THE PLANT LIST ON SHEET LP-2 SO
 THAT THE COLUMNS FOR WATER USAGE AND NATIVE LINE UP.
  
  
 CONDITIONS OF APPROVAL
 1. PRIOR TO THE REMOVAL OR RELOCATION OF ANY TREES ON
 THE PROPERTY, A TREE ALTERATION PERMIT SHALL BE
 SUBMITTED, REVIEWED AND APPROVED BY THE DEVELOPMENT
 SERVICES DEPARTMENT, PLANNING DIVISION.
  
  

Review Stop L LANDSCAPING
Rev No 2 Status F Date 01-31-2023 Cont ID  
Sent By rcaranci Date 01-31-2023 Time 16:35 Rev Time 0.00
Received By rcaranci Date 01-31-2023 Time 16:35 Sent To  
Notes
2023-01-31 16:35:52FROM: RAY CARANCI, SENIOR LANDSCAPE PLANNER
 561-822-1462
 PROJECT: TROPICANA SELF STORAGE Z22080024
 JANUARY 31, 2023
 I HAVE REVIEWED THE ABOVE REFERENCED PETITION, AND
 PROVIDE THE FOLLOWING COMMENTS:
  
  
 1. SATISFIED. CORRECT THE TREE DISPOSITION PLAN TO SHOW
 TREES #7, 8, 9, 10, 11, AND 12 OFFSITE ON THE CHART.
  
 2. SATISFIED. PER SECTION 94-442(B)Q. SHOW TREES AND
 PALMS ON THE ADJACENT PROPERTIES WITHIN 10 FEET OF THE
 PROPERTY LINE AND PLACE BUFFER TREES ACCORDINGLY TO
 AVOID CANOPY CONFLICT.
  
 3. SATISFIED. WATER LINES SHOULD BE SHIFTED TO THE
 SOUTH TO AVOID CONFLICT WITH THE LANDSCAPE ISLAND AND
 TREE.
  
 4. PARTIALLY SATISFIED. SHEET LP-3 WITH EXHIBIT SHOWS
 THE PARKING AREA SURFACE CALCULATIONS, PARKING SPACE
 AREAS AND LANDSCAPE AREAS PROVIDED TO DEMONSTRATE
 COMPLIANCE WITH SECTIONS 94-443 (C)(3) AND (4). REFER
 TO FIGURE XIV-1, THE ACTUAL PROVIDED INTERIOR LANDSCAPE
 SQUARE FOOTAGE THAT CAN BE COUNTED MUST BE WITHIN THE
 EXTERIOR EDGE OF THE VEHICULAR USE AREA. LANDSCAPE
 BUFFERS AND AREAS OUTSIDE THE PERIMETER OF THE
 VEHICULAR USE AREA CANNOT BE COUNTED. LOADING SPACES
 MUST BE COUNTED IN THE OTHER VEHICULAR USE AREA.
 REVISE.
 1/31/23 OTHER VEHICULAR USE AREA SHOULD BE 97,377 SF
 PLUS 5,586 SQ FT = 102,963 SQ FT
 SO REQUIRED INTERIOR LANDSCAPE AREA SHOULD BE 140 SQ FT
 PLUS 4119 SQ FT = 4259 SQ FT
 CORRECT THIS ON SHEET LP-3.
  
 5. SATISFIED. PROVIDE SCREENING HEDGE FOR THE BACKFLOW
 PREVENTERS.
  
 ADDITIONAL COMMENTS 1/31/23:
  
 6. THIS SITE AND LANDSCAPE PLAN IS BASED ON A PROPOSED
 CODE CHANGE FOR PARKING REQUIREMENTS, SO WILL NOT BE
 ABLE TO BE FINALIZED AND PASS THE REVIEW UNTIL THE
 PARKING MEETS THE CODE REQUIREMENT.
  
 7. ADJUST THE PLANT LIST ON SHEET LP-2 SO THAT THE
 COLUMNS FOR WATER USAGE AND NATIVE LINE UP.
  
  
 CONDITIONS OF APPROVAL
 1. PRIOR TO THE REMOVAL OR RELOCATION OF ANY TREES ON
 THE PROPERTY, A TREE ALTERATION PERMIT SHALL BE
 SUBMITTED, REVIEWED AND APPROVED BY THE DEVELOPMENT
 SERVICES DEPARTMENT, PLANNING DIVISION.
  

Review Stop L LANDSCAPING
Rev No 1 Status F Date 09-07-2022 Cont ID  
Sent By rcaranci Date 09-07-2022 Time 14:47 Rev Time 0.00
Received By rcaranci Date 09-07-2022 Time 14:47 Sent To  
Notes
2022-09-07 14:49:35FROM: RAY CARANCI, SENIOR LANDSCAPE PLANNER
 561-822-1462
 PROJECT: TROPICANA SELF STORAGE Z22080024
 SEPTEMBER 7, 2022
 I HAVE REVIEWED THE ABOVE REFERENCED PETITION, AND
 PROVIDE THE FOLLOWING COMMENTS:
  
  
 1. CORRECT THE TREE DISPOSITION PLAN TO SHOW TREES #7,
 8, 9, 10, 11, AND 12 OFFSITE ON THE CHART.
  
 2. PER SECTION 94-442(B)Q. SHOW TREES AND PALMS ON THE
 ADJACENT PROPERTIES WITHIN 10 FEET OF THE PROPERTY LINE
 AND PLACE BUFFER TREES ACCORDINGLY TO AVOID CANOPY
 CONFLICT.
  
 3. WATER LINES SHOULD BE SHIFTED TO THE SOUTH TO AVOID
 CONFLICT WITH THE LANDSCAPE ISLAND AND TREE.
  
 4. SHEET LP-3 WITH EXHIBIT SHOWS THE PARKING AREA
 SURFACE CALCULATIONS, PARKING SPACE AREAS AND LANDSCAPE
 AREAS PROVIDED TO DEMONSTRATE COMPLIANCE WITH SECTIONS
 94-443 (C)(3) AND (4). REFER TO FIGURE XIV-1, THE
 ACTUAL PROVIDED INTERIOR LANDSCAPE SQUARE FOOTAGE THAT
 CAN BE COUNTED MUST BE WITHIN THE EXTERIOR EDGE OF THE
 VEHICULAR USE AREA. LANDSCAPE BUFFERS AND AREAS OUTSIDE
 THE PERIMETER OF THE VEHICULAR USE AREA CANNOT BE
 COUNTED. LOADING SPACES MUST BE COUNTED IN THE OTHER
 VEHICULAR USE AREA. REVISE.
 5. PROVIDE SCREENING HEDGE FOR THE BACKFLOW PREVENTERS.
  
 CONDITIONS OF APPROVAL
 1. PRIOR TO THE REMOVAL OR RELOCATION OF ANY TREES ON
 THE PROPERTY, A TREE ALTERATION PERMIT SHALL BE
 SUBMITTED, REVIEWED AND APPROVED BY THE DEVELOPMENT
 SERVICES DEPARTMENT, PLANNING DIVISION.
  

Review Stop PARK PARKING
Rev No 1 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time  
Received By   Date   Time   Sent To  
Notes
***NONE***

Review Stop POLICE POLICE
Rev No 1 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time  
Received By   Date   Time   Sent To  
Notes
***NONE***

Review Stop PU PUBLIC UTILITIES
Rev No 4 Status P Date 06-23-2023 Cont ID  
Sent By relizond Date 06-23-2023 Time 13:51 Rev Time 0.00
Received By relizond Date 06-23-2023 Time 13:46 Sent To  
Notes
2023-06-23 13:51:22-CALLOUT FOR CUT-IN TO EXISTING VCP STILL SHOWN
 -IF MANHOLE DETERMINED TO NEED REPLACEMENT, ADJUST
 INVERTS SO THAT PIPE CAN HAVE AT LEAST 1/2 FOOT OF
 CLEARANCE UNDERNEATH EXISTING STORM.
  

Review Stop PU PUBLIC UTILITIES
Rev No 3 Status F Date 03-31-2023 Cont ID  
Sent By relizond Date 03-31-2023 Time 13:12 Rev Time 0.00
Received By relizond Date 03-31-2023 Time 13:12 Sent To  
Notes
2023-03-31 13:12:01DEMO SHEET
  
 -SHOW SECOND MANHOLE FROM SANITARY RUN
 -CALL OUT EXISTING MAINS SIZES AND MATERIALS
 -METER TO THE NORTH NOT SHOW
  
 WATER AND SEWER SHEET
  
 -PROVIDE 2ND VALVE FOR FIRELINE AT R/W LINE
 -PROVIDE PROFILE FOR PROPOSED SEWER LATERAL TO ENSURE
 CUT IN WILL NOT INTERFERE WITH EXISTING DRAINAGE
 -PROVIDE PROFILES FOR FIRE LIE AND WATER SERVICE
 -PROVIDE WATER SHUTDOWN PLAN FOR THE CUT IN TEE TO
 ENSURE LEAST AMOUNT OF CUSTOMERS WILL BE OUT OF SERVICE
 (IS A WET TAP NOT POSSIBLE?)
 -CONDITION FOR SEWER MAIN NEEDS TO BE CHECKED TO SEE IF
 PVC REPLACEMENT IS NECESSARY

Review Stop PU PUBLIC UTILITIES
Rev No 2 Status F Date 02-03-2023 Cont ID  
Sent By relizond Date 02-03-2023 Time 09:20 Rev Time 0.00
Received By relizond Date 02-03-2023 Time 08:21 Sent To  
Notes
2023-02-03 09:15:19-PREVIOUS COMMENT REGARDING CCTV NOT ADDRESSED
 -6" FIRELINE PROPOSED FOR REMOVAL IS SHOWN ON GIS AS A
 1" LATERAL SERVICE LINE. PLEASE VERIFY SIZE AMD
 MATERIAL. (WILL STILL NEED TO BE CUT AND CAP AT MAIN IF
 NOT USED)
 -A SECOND WATER SERVICE IS SHOWN ON GIS THAT IS NOT
 REFLECTED IN THE PLANS. PLEASE ACCOUNT FOR THIS SERVICE
 AND NOTE WHETHER IT WILL REMAIN OR NEED TO BE CUT AND
 CAP AT MAIN.
 -MANHOLE THAT LATERAL PROPOSED FOR REMOVAL IS CONNECTED
 TO WILL NEED TO BE REHABBED.
 -CLEANOUT NEAR PROPERTY LINE NEEDS TO BE NOTED AS POINT
 OF SERVICE. IF ON PRIVATE PROPERTY, AN EASEMENT WILL BE
 REQUIRED.
  
 RICKY ELIZONDO [email protected]

Review Stop PU PUBLIC UTILITIES
Rev No 1 Status F Date   Cont ID  
Sent By   Date   Time   Rev Time 0.00
Received By mtechnow Date 09-08-2022 Time 12:21 Sent To  
Notes
2022-09-08 12:23:26-SEE RICK ROSSANO'S LIST OF STANDARD COMMENTS FOR PLAN
 SUBMITTAL. INCLUDE LOS CALCS, FIRE FLOW ON PLAN SHEET.
 -SUBMIT CCTV OF SANITARY SEWER WITHIN PROJECT LIMITS.
 REHAB TO BE DONE AS REQUIRED.
 -CONCEPTUAL PLANS ARE APPROVED.
  

Review Stop PU-CS PUBLIC UTILITIES CUSTOMER SRVC
Rev No 2 Status P Date 01-23-2023 Cont ID  
Sent By mhurley Date 01-23-2023 Time 14:58 Rev Time 0.00
Received By mhurley Date   Time   Sent To  
Notes
***NONE***

Review Stop PU-CS PUBLIC UTILITIES CUSTOMER SRVC
Rev No 1 Status F Date 09-06-2022 Cont ID  
Sent By mhurley Date 09-06-2022 Time 16:19 Rev Time 0.00
Received By mhurley Date   Time   Sent To  
Notes
2022-09-06 16:19:05PLEASE PROVIDE WRITTEN RESPONSES TO THE FOLLOWING:
 -SOUTHWESTERN PROPOSED DRIVEWAY FLARE IS EXTENDING PAST
 PROPERTY LINE.
 -SHOW AND LABEL 12 FOOT D.E. RUNNING THROUGH PROPERTY
 ON CIVIL PLANS AS SHOWN ON SURVEY.
 -40 FOOT CANAL EASEMENT IS NOT SHOWING ON CIVIL PLANS
 AS SHOWN ON SURVEY. PLEASE UPDATE.
 -SURVEY NOTE NUMBER 5 SAYS THAT THERE MAY BE ADDITIONAL
 EASEMENTS OR RESTRICTIONS NOT SHOWN ON SURVEY.
 -ADD DEMO PLAN SHEET TO ENGINEERING PLAN SET IF THERE
 WILL BE DEMOLITION.
 -SHOW AND LABEL EXISTING AND PROPOSED RIGHT OF WAY
 SIDEWALK.
 -WILL THE NORTHERN SWING GATE HIT THE DUMPSTER
 STRUCTURE WHEN OPENS? ALSO WILL THAT SWING GATE HIT
 VEHICLES TRAVELING NORTH PAST IT?
 -WILL MARQUEE SIGN REMAIN, OR IS REPLACEMENT PROPOSED?
 ALSO, PLEASE SHOW AND LABEL IT ON ENGINEERING PLANS.
 -SHOW AND LABEL ALL UTILITY POLES AND LIGHT POLES NEAR
 PROPERTY AND WHAT IS HAPPENING TO THEM.
 -HISTORIC PICTURES SHOW EXISTING FENCES AT SOUTH AND
 EAST SIDES OF PROPERTY. WHO OWNS THOSE FENCES AND ARE
 THE PROPOSED FENCES ADDITIONS OR REPLACEMENTS?
 -PROPOSED SOUTHWESTERN DRIVEWAY LOOKS TO CONFLICT WITH
 EXISTING STORM STRUCTURE.
 -UTILITY BILLING SYSTEM IS SHOWING EXISTING FIRELINE
 WATER SERVICE FOR THE ADDRESS. VERIFY IF THAT IS
 CORRECT AND IF SO, SHOW AND LABEL ON PLANS.
 -VERIFY IF PROPOSED PRIVATE FIRE SYSTEM WILL HAVE ANY
 AUXILIARY WATER SUPPLIES SUCH AS WELLS CONNECTED TO IT.
 -EXISTING DOMESTIC METER SIZE IS 1.5 INCH PER UTILITY
 BILLING SYSTEM.
 -ADD WATER AND SEWER DEMAND CALCULATIONS TO WATER PLAN.
 -SHOW AND LABEL EXISTING SEWER LATERAL AND WHAT IS
 HAPPENING TO IT.
 -CALLOUT HORIZONTAL CLEARANCE DISTANCE BETWEEN SEWER
 LATERAL AND POTABLE PLUMBING.
 -ARCHITECTURAL PLAN SHOWS ADDITIONAL DUMPSTER NOT SHOWN
 ON ENGINEERING PLAN.
 -ADD ENGINEERING PLAN SHEET SHOWING RV PARKING BEFORE
 PHASE II IS COMPLETE.
 -ON LP2, SOME OF THE RV PARKING SPOTS LOOK PROBLEMATIC
 WHERE THE RV?S MAY HIT THE SWING GATES COMING OUT OF
 THE PARKING SPOTS.
 -WILL THE IRRIGATION RUN OFF OF DOMESTIC WATER SERVICE,
 OR IS A SEPARATE METERED IRRIGATION WATER SERVICE
 NEEDED?
 RESPECTFULLY,
 MARK HURLEY [email protected]

Review Stop PW PUBLIC WORKS
Rev No 4 Status P Date 05-23-2023 Cont ID  
Sent By   Date 05-23-2023 Time   Rev Time 0.00
Received By   Date 05-23-2023 Time   Sent To  
Notes
2023-05-23 11:23:21NO FURTHER COMMENTS

Review Stop PW PUBLIC WORKS
Rev No 3 Status P Date 03-21-2023 Cont ID  
Sent By   Date 03-21-2023 Time   Rev Time 0.00
Received By   Date 03-21-2023 Time   Sent To  
Notes
2023-03-21 09:44:43NO FURTHER COMMECTS FROM PUBLIC WORKS.

Review Stop PW PUBLIC WORKS
Rev No 2 Status F Date 01-19-2023 Cont ID  
Sent By   Date 01-19-2023 Time   Rev Time 0.00
Received By   Date 01-19-2023 Time   Sent To  
Notes
2023-01-19 14:50:08PLEASE PROVIDE THE FOLLOWINGS:
 1- LOS (LEVEL OF SERVICE ANALYSIS) TO REFLECT THE SOLID
 WASTE VOLUME PRODUCED ALONG WITH THE SIZE, TYPE AND
 QUANTITY OF THE CONTAINER (I.E. DUMPSTER/COMPACTOR)
 THAT WILL BE UTILIZED FOR THE SANITATION SERVICE.
 2- REVISED AUTOTURN FOR THE SANITATION COLLECTION
 (FRONT LOADER) TRUCK WITH MODIFIED TURNING RADII TO
 PREVENT ANY ENCROACHMENT.
  
  
 MATT HEJAZI
 DEPT. OF PUBLIC WORKS
 [email protected]
 561-822-2045

Review Stop PW PUBLIC WORKS
Rev No 1 Status F Date 08-31-2022 Cont ID  
Sent By   Date 08-31-2022 Time   Rev Time  
Received By   Date 08-31-2022 Time   Sent To  
Notes
2022-08-31 09:49:40 
 PLEASE PROVIDE THE FOLLOWINGS:
 1- LOS (LEVEL OF SERVICE ANALYSIS) TO REFLECT THE SOLID
 WASTE VOLUME PRODUCED ALONG WITH THE SIZE, TYPE AND
 QUANTITY OF THE CONTAINER (I.E. DUMPSTER/COMPACTOR)
 THAT WILL BE UTILIZED FOR THE SANITATION SERVICE.
 2- DUMPSTER ENCLOSURE DETAIL. FOR A FREESTANDING SITE
 DUMPSTER ENCLOSURE, THE ENCLOSURE SHALL COMPLY WITH THE
 LATEST REVISION OF CITY OF WEST PALM BEACH GENERAL
 CONSTRUCTION-GARBAGE ENCLOSURE STANDARD, GC-7. (LINK TO
 THE LATEST REVISION OF THE GC-7 DOCUMENT: HTTPS://WWW.W
 PB.ORG/HOME/SHOWPUBLISHEDDOCUMENT/3690/6376290604221000
 00)
 3- AUTOTURN EXHIBIT WITH DYNAMIC ENVELOPE AND THE
 VEHICLE?S WHEEL PATH IDENTIFIED WITH DIFFERENT COLORS
 FOR THE SANITATION SERVICE, FRONT LOADER TRUCK WITH THE
 FOLLOWING SPECS:
 - DUAL AXLES
 - TRUCK LENGTH: 35 FT
 - TRUCK WIDTH: 11 FT
 - TURNING RADIUS:
 - SAE TURNING RADIUS: 32.5 FT
 - CURB-TO-CURB DIAMETER: 74 FT
 - WALL-TO-WALL DIAMETER: 86.3 FT
 4- DESIGNATED LOCATION FOR THE BULK ITEM PICK UP AND
 RECYCLING CONTAINERS, IF APPLICABLE.
 5- IN CASE OF PROPOSING ADDITION OF ANY NEW CAN(S) IN
 THE CITY`S RIGHT-OF-WAY , THE LOCATION AND QUANTITY OF
 THE CAN(S) SHALL BE REVIEWED AND APPROVED BY PUBLIC
 WORKS DEPARTMENT AND THE CAN(S) SHALL BE TYPE, SIZE AND
 COLOR APPROVED BY PUBLIC WORKS DEPARTMENT. THE BUILDING
 MAINTENANCE IS RESPONSIBLE TO MAINTAIN AND SERVICE THE
 CAN(S).
 6- ALL THE PARKING STALL PAINTING SHALL COMPLY WITH THE
 CITY`S MUNICIPAL CODE SECTION 94-485 AND FLORIDA
 STATUES [553.5041 F.S.].
 7- SIGNAGE PLAN. ALL STRIPING AND SIGNAGE SHALL COMPLY
 WITH THE LATEST CITY OF WEST PALM BEACH STANDARD
 DETAILS AND MEET THE M.U.T.C.D. LATEST EDITION.
 8- ALL PAVEMENT MARKING , SIGNING AND SIDEWALK DAMAGED
 DURING CONSTRUCTION SHALL BE RESTORED.
  
  
  
 MATT HEJAZI
 DEPT. OF PUBLIC WORKS
 [email protected]
 561-822-2045
  

Review Stop STORM STORMWATER
Rev No 4 Status F Date 06-27-2023 Cont ID  
Sent By tward Date 06-27-2023 Time 14:36 Rev Time 0.00
Received By tward Date 06-27-2023 Time 14:38 Sent To  
Notes
2023-06-27 14:37:09THE FOLLOWING COMMENTS ARE FROM THE REVIEW OF THE
 5/11/2023 SUBMITTAL.
  
 1. [SATISFIED] FLORIDA MANGO IS MAINTAINED BY PALM
 BEACH COUNTY.
  
 2. [SATISFIED] THE CITY'S OFFICIAL VERTICAL DATUM IS
 NGVD1929. THE CITY HAS ALLOWED THE USE OF NAVD1988 AS
 LONG AS THE CONVERSION EQUATION TO NGVD1929 AT THE
 PROJECT LOCATION IS PROVIDED. PROVIDE THE VERTICAL
 DATUM CONVERSION TO NGVD1929 ON THE SURVEY. PROVIDE
 VERTICAL DATUM REFERENCE AND CONVERSION EQUATION ON
 EVERY ENGINEERING SHEET WITH ELEVATION INFORMATION.
  
 3. [SATISFIED] SITE IS WITHIN A SPECIAL FLOOD HAZARD
 AREA. STRUCTURES ARE TO HAVE MINIMUM TWO FEET OF
 FREEBOARD ABOVE THE BASE FLOOD ELEVATION.
  
 4. [SATISFIED - THE BLEEDER IS LOCATED DOWNSTREAM FROM
 WEIR THAT SURCHARGES THE EXFILTRATION TRENCHES.] THE
 CITY DOES NOT ALLOW THE USE OF BLEEDERS WITHIN THE WEIR
 WITH EXFILTRATION TRENCH SYSTEMS.
  
 5. [PARTIALLY SATISFIED - SEE NEW COMMENTS BELOW]
 PROVIDE CROSS SECTIONS FOR ALL SIDES OF THE PROPERTY
 FROM 10 FEET OUTSIDE THE PROPERTY TO THE BUILDING FACE.
 SHOW AND LABEL SURFACE FEATURES, GRADE BREAKS, PROPERTY
 LINE, SURFACE SLOPES, STREET NAMES, ETC.
  
 6. [PARTIALLY SATISFIED - SEE NEW COMMENTS BELOW]
 PROVIDE CROSS SECTIONS AT THE DRIVEWAYS FROM CENTERLINE
 OF THE ROAD TO 5 FEET PAST THE HIGH POINT. SHOW AND
 LABEL SURFACE FEATURES, GRADE BREAKS, RIGHT OF WAY
 LINE, STREET NAME, SURFACE SLOPES, ETC.
  
 7. [PARTIALLY SATISFIED - THE WEIR ELEVATION IS ONLY
 4??? BELOW THE TOP SLAB OF THE CONTROL STRUCTURE. IF
 THE SYSTEM WAS MODELED WITH A H&H MODEL, WHAT WERE THE
 PEAK STAGES OVER THE WEIR?] THE GRATE ELEVATION OF
 STRUCTURES CB#1 AND CB#8 ARE AT OR BARELY HIGHER THAN
 THE WEIR ELEVATION. THERE WILL BE PONDING AROUND THESE
 STRUCTURES WHENEVER THERE IS DISCHARGE INTO THE CANAL.
  
 8. [PARTIALLY SATISFIED - LABEL ON PGD PLANS AND WATER
 & SEWER PLANS] LABEL EXISTING UTILITIES (SIZE,
 MATERIAL).
  
 9. [NOT SATISFIED - TRENCH CUTS INTO THE RIGHT OF WAY
 PAVEMENT TO INSTALL UTILITY SERVICES WILL REQUIRE MILL
 AND OVERLAY PER THE COUNTY DETAILS] SHOW MILL AND
 RESURFACING LIMITS.
  
 10. [SATISFIED] SHOW THE EXISTING CURB AND GUTTER ALONG
 FLORIDA MANGO. SHOW DROP CURB ACROSS THE PROPOSED
 DRIVEWAYS.
  
 11. [SATISFIED] CAN SOUTH DRIVEWAY BE ADJUSTED TO AVOID
 THE EXISTING CATCH BASIN?
  
 12. [SATISFIED] DRIVEWAY APRONS SHOULD BE CONCRETE
 WITHIN THE RIGHT OF WAY.
  
 13. [SATISFIED] SHOW AND LABEL AND PERIMETER BERM THAT
 WILL BE NEEDED.
  
 NEW COMMENTS (5/11/2023 SUBMITTAL)
  
 14. SECTION A-A
  A. SHOULD THE CONCRETE DRIVEWAY DIMENSION EXTEND TO
 THE BACK OF SIDEWALK (WEST PROPERTY LINE)?
  B. LABEL THE R/W AS N. FLORIDA MANGO ROAD.
  
 15. SECTION B-B
  A. SHOULD THE 14??? CONCRETE DRIVEWAY DIMENSION EXTEND
 TO THE BACK OF SIDEWALK (WEST PROPERTY LINE)?
  B. LABEL THE R/W AS N. FLORIDA MANGO ROAD.
  
 16. SECTIONS D-D, E-E, F-F, G-G
  A. IN ADDITION TO THE PERIMETER BERM AT OR NEAR THE
 PROPERTY LINE, SHOW A SWALE WITHIN THE BERM TO PREVENT
 DIRECT RUNOFF TO THE ADJACENT PROPERTIES.
  
 17. PROVIDE WRITTEN RESPONSES EXPLAINING HOW THESE
 COMMENTS WERE ADDRESSED.
  
 TRACY WARD, PE
 SENIOR STORMWATER ENGINEER
 ENGINEERING SERVICES DEPARTMENT
 561-494-1120 (O)
 [email protected]
  

Review Stop STORM STORMWATER
Rev No 3 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time 0.00
Received By   Date   Time   Sent To  
Notes
***NONE***

Review Stop STORM STORMWATER
Rev No 2 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time 0.00
Received By   Date   Time   Sent To  
Notes
***NONE***

Review Stop STORM STORMWATER
Rev No 1 Status F Date 09-08-2022 Cont ID  
Sent By tward Date 09-08-2022 Time 13:06 Rev Time 0.00
Received By tward Date 09-08-2022 Time 13:07 Sent To  
Notes
2022-09-08 13:07:23THIS IS A CONCEPTUAL LEVEL REVIEW. CONSTRUCTION LEVEL
 DETAILS, DESIGN CALCULATIONS AND THE POLLUTION
 PREVENTION PLAN WILL BE REVIEWED AS PART OF THE
 ENGINEERING DEVELOPMENT APPROVAL AND BUILDING PERMIT
 APPLICATION PROCESSES.
  
 THE FOLLOWING COMMENTS MUST BE ADDRESSED PRIOR TO SITE
 PLAN APPROVAL:
  
 1. FLORIDA MANGO IS MAINTAINED BY PALM BEACH COUNTY.
  
 2. THE CITY?S OFFICIAL VERTICAL DATUM IS NGVD1929. THE
 CITY HAS ALLOWED THE USE OF NAVD1988 AS LONG AS THE
 CONVERSION EQUATION TO NGVD1929 AT THE PROJECT LOCATION
 IS PROVIDED. PROVIDE THE VERTICAL DATUM CONVERSION TO
 NGVD1929 ON THE SURVEY. PROVIDE VERTICAL DATUM
 REFERENCE AND CONVERSION EQUATION ON EVERY ENGINEERING
 SHEET WITH ELEVATION INFORMATION.
  
 3. SITE IS WITHIN A SPECIAL FLOOD HAZARD AREA.
 STRUCTURES ARE TO HAVE MINIMUM TWO FEET OF FREEBOARD
 ABOVE THE BASE FLOOD ELEVATION.
  
 4. THE CITY DOES NOT ALLOW THE USE OF BLEEDERS WITHIN
 THE WEIR WITH EXFILTRATION TRENCH SYSTEMS.
  
 5. PROVIDE CROSS SECTIONS FOR ALL SIDES OF THE PROPERTY
 FROM 10 FEET OUTSIDE THE PROPERTY TO THE BUILDING FACE.
 SHOW AND LABEL SURFACE FEATURES, GRADE BREAKS, PROPERTY
 LINE, SURFACE SLOPES, STREET NAMES, ETC.
  
 6. PROVIDE CROSS SECTIONS AT THE DRIVEWAYS FROM
 CENTERLINE OF THE ROAD TO 5 FEET PAST THE HIGH POINT.
 SHOW AND LABEL SURFACE FEATURES, GRADE BREAKS, RIGHT OF
 WAY LINE, STREET NAME, SURFACE SLOPES, ETC.
  
 7. THE GRATE ELEVATION OF STRUCTURES CB#1 AND CB#8 ARE
 AT OR BARELY HIGHER THAN THE WEIR ELEVATION. THERE WILL
 BE PONDING AROUND THESE STRUCTURES WHENEVER THERE IS
 DISCHARGE INTO THE CANAL.
  
 8. LABEL EXISTING UTILITIES (SIZE, MATERIAL).
  
 9. SHOW MILL AND RESURFACING LIMITS.
  
 10. SHOW THE EXISTING CURB AND GUTTER ALONG FLORIDA
 MANGO. SHOW DROP CURB ACROSS THE PROPOSED DRIVEWAYS.
  
 11. CAN SOUTH DRIVEWAY BE ADJUSTED TO AVOID THE
 EXISTING CATCH BASIN?
  
 12. DRIVEWAY APRONS SHOULD BE CONCRETE WITHIN THE RIGHT
 OF WAY.
  
 13. SHOW AND LABEL AND PERIMETER BERM THAT WILL BE
 NEEDED.
  
 THE FOLLOWING COMMENTS MUST BE ADDRESSED PRIOR TO
 ISSUANCE OF CONSTRUCTION AUTHORIZATION INCLUDING
 BUILDING PERMITS AND ENGINEERING DEVELOPMENT APPROVAL.
  
 1. DRAINAGE SYSTEM TO BE DESIGNED TO MEET SFWMD ERP
 CRITERIA. STORMWATER CALCULATIONS WILL BE REVIEWED WITH
 THE ENGINEERING PERMIT SUBMITTAL.
  
 2. PROVIDE COPY OF SFWMD ERP PERMIT BEFORE START OF
 CONSTRUCTION.
  
 3. PROVIDE EROSION AND SEDIMENT CONTROL PLAN WITH THE
 ENGINEERING PERMIT SUBMITTAL.
  
 TRACY WARD, PE
 SENIOR STORMWATER ENGINEER
 ENGINEERING SERVICES DEPARTMENT
 561-494-1120 (O)
 561-351-0510 (M)
 [email protected]
  

Review Stop SURVEY SURVEYING
Rev No 3 Status P Date 04-12-2023 Cont ID  
Sent By vnoel Date 04-12-2023 Time 14:03 Rev Time 0.00
Received By vnoel Date   Time   Sent To  
Notes
***NONE***

Review Stop SURVEY SURVEYING
Rev No 2 Status F Date 01-31-2023 Cont ID  
Sent By vnoel Date 01-31-2023 Time 07:36 Rev Time 0.00
Received By vnoel Date   Time   Sent To  
Notes
2023-01-31 07:38:361. I'LL DEFER TO TRACY WARD, STORMWATER ENGINEER AS TO
 CATCH BASIN LOCATION IN FRONT OF DUMPSTER.
 2. DID NOT SEE RESPONSES TO STORMWATER COMMENTS.

Review Stop SURVEY SURVEYING
Rev No 1 Status F Date 09-06-2022 Cont ID  
Sent By vnoel Date 09-06-2022 Time 13:41 Rev Time  
Received By vnoel Date   Time   Sent To  
Notes
2022-09-06 13:51:521. SOUTH ENTRANCE TURN-OUT CANNOT CROSS INTO ADJOINING
 PROPERTY.
 2. PALM BEACH COUNTY PERMIT WILL BE REQUIRED FOR
 FLORIDA MANGO.
 3. MAY WANT TO MOVE SWING GATE IN CONFLICT WITH
 DUMPSTER GATES. ALSO RELOCATE CATCH BASIN AWAY FROM
 FRONT OF DUMPSTER.
 4. WHERE ARE THE CONTROLS FOR THE SWING GATES?

Review Stop TRAFFIC TRAFFIC ENGINEERING
Rev No 2 Status P Date 01-19-2023 Cont ID  
Sent By   Date 01-19-2023 Time   Rev Time 0.00
Received By   Date 01-19-2023 Time   Sent To  
Notes
2023-01-19 17:12:13NO FURTHER COMMENTS.
  
 PAST COMMENTS BELOW.
  
 1) SATISFIED. PROVIDE COUNTY TPS LETTER
 2) SATISFIED. PROVIDE A SIGNAGE AND PAVEMENT MARKING
 PLAN. INCLUSIVE OF ALL FEATURES WITHIN THE PROPOSED
 DEVELOPMENT AND ALONG ALL ROADS FRONTING THE SITE
 3) SATISFIED. PROVIDE AUTOTURN ANALYSIS FOR GARBAGE
 TRUCK AND/OR SERVICE VEHICLES DRIVING IN AND OUT OF THE
 PROPOSED DEVELOPMENT WITH VEHICLE DYNAMIC ENVELOPES AND
 WHEEL PATHS CLEARLY DISTINCT AND DEFINED IN DIFFERENT
 COLORS. PROVIDE THE ANALYSIS IN A SEPARATE SHEET
 4) SATISFIED. PROVIDE A PARKING TABLE SHOWCASING THE
 NUMBER OF REQUIRED AND PROVIDED PARKING SPACES,
 INCLUSIVE OF ADA AND BICYCLE ONES
 5) SATISFIED. IT IS RECOMMENDED TO HAVE ONE-WAY
 COUNTERCLOCKWISE CIRCULATION AROUND THE BACK OF THE
 BUILDING. THE CHANGE FROM ONE-WAY TO TWO-WAY AT THE
 NORTH-EAST AND SOUTH-EAST CORNER OF THE PROPOSED
 DEVELOPMENT IS A SAFETY HAZARD, UNLESS PROPER MARKING,
 SIGNAGE AND TURN-AROUND SPACE ARE PROVIDED
  
 VALERIO ORICCHIO
 CITY TRANSPORTATION ENGINEER
 561-494-1092
 [email protected]
  
  

Review Stop TRAFFIC TRAFFIC ENGINEERING
Rev No 1 Status F Date 09-08-2022 Cont ID  
Sent By   Date 09-08-2022 Time   Rev Time  
Received By   Date 09-08-2022 Time   Sent To  
Notes
2022-09-08 10:32:551) PROVIDE COUNTY TPS LETTER
 2) PROVIDE A SIGNAGE AND PAVEMENT MARKING PLAN.
 INCLUSIVE OF ALL FEATURES WITHIN THE PROPOSED
 DEVELOPMENT AND ALONG ALL ROADS FRONTING THE SITE
 3) PROVIDE AUTOTURN ANALYSIS FOR GARBAGE TRUCK AND/OR
 SERVICE VEHICLES DRIVING IN AND OUT OF THE PROPOSED
 DEVELOPMENT WITH VEHICLE DYNAMIC ENVELOPES AND WHEEL
 PATHS CLEARLY DISTINCT AND DEFINED IN DIFFERENT COLORS.
 PROVIDE THE ANALYSIS IN A SEPARATE SHEET
 4) PROVIDE A PARKING TABLE SHOWCASING THE NUMBER OF
 REQUIRED AND PROVIDED PARKING SPACES, INCLUSIVE OF ADA
 AND BICYCLE ONES
 5) IT IS RECOMMENDED TO HAVE ONE-WAY COUNTERCLOCKWISE
 CIRCULATION AROUND THE BACK OF THE BUILDING. THE CHANGE
 FROM ONE-WAY TO TWO-WAY AT THE NORTH-EAST AND
 SOUTH-EAST CORNER OF THE PROPOSED DEVELOPMENT IS A
 SAFETY HAZARD, UNLESS PROPER MARKING, SIGNAGE AND
 TURN-AROUND SPACE ARE PROVIDED
  
 VALERIO ORICCHIO
 CITY TRANSPORTATION ENGINEER
 561-494-1092
 [email protected]
  
  

Review Stop Z ZONING
Rev No 4 Status F Date 06-09-2023 Cont ID  
Sent By kdefranc Date 06-09-2023 Time 15:14 Rev Time 0.00
Received By kdefranc Date 06-09-2023 Time 15:13 Sent To  
Notes
2023-06-09 15:14:326/9/23 ??? FAILED
  
  
 PREVIOUS REVIEW COMMENTS:
 1. PER CITY CODE, PARKING WAIVERS FOR PDS CAN ONLY BE
 GRANTED IF THE PROJECT IS LOCATED EAST OF INTERSTATE
 95, OR EAST OF AUSTRALIAN AVENUE BETWEEN OKEECHOBEE
 BOULEVARD AND BELVEDERE ROAD. THE SUBJECT PROPERTY DOES
 NOT FALL WITHIN THIS AREA, THEREFORE ALL PARKING AND
 LOADING SPACES SHALL BE PROVIDED PURSUANT TO ARTICLE XV
 OF THE ZONING AND LAND DEVELOPMENT REGULATIONS. [NOT
 SATISFIED - HOWEVER, SUBMITTED TEXT CHANGE (ZLDRS)
 APPLICATION ACKNOWLEDGED]
 2. PER ARTICLE XV, NUMBER OF PARKING SPACES WAS
 CALCULATED INCORRECTLY 33 TOTAL PARKING SPACES ARE
 NEEDED (3 FOR THE OFFICE SPACE, 5 FOR THE FIRST 10,000
 SQ FEET OF WAREHOUSE SPACE, 24.32 (ROUNDED UP TO 25)
 FOR THE REMAINING 98,292 SQ FEET OF WAREHOUSE SPACE.)
 [RESPONSE PROVIDED]
 3. THE SITE PLAN SHOWS OPPOSITE ONE-WAY ROADS TO THE
 NORTH AND SOUTH OF THE BUILDING, AND TWO WAY ROADS TO
 THE EAST AND WEST. THIS DOES NOT MAKE SENSE FROM A
 TRAFFIC FLOW PERSPECTIVE. [SATISFIED]
 4. PROVIDE A PHOTOMETRIC PLAN SHOWING COMPLIANCE WITH
 THE FOLLOWING STANDARD (ANY SOURCE OF ILLUMINATION
 LOCATED WITHIN A COMMERCIAL OR INDUSTRIAL PLANNED
 DEVELOPMENT DISTRICT SHALL NOT EXCEED ONE FOOTCANDLE AT
 OR BEYOND THE BOUNDARIES OF SUCH DEVELOPMENT.)
 [SATISFIED]
 5. NOTE THAT THE FOLLOWING CPD STANDARD (OUTDOOR
 STORAGE FACILITIES ARE PROHIBITED IN ANY COMMERCIAL
 PLANNED DEVELOPMENT DISTRICT, UNLESS OUTDOOR STORAGE IS
 EXPRESSLY APPROVED BY THE CITY COMMISSION AS PART OF
 THE ORDINANCE ADOPTING THE COMMERCIAL PLANNED
 DEVELOPMENT. APPROVAL OF OUTDOOR STORAGE IN A
 COMMERCIAL PLANNED DEVELOPMENT DISTRICT SHALL INCLUDE
 MITIGATION MEASURES TO PROTECT ADJACENT PROPERTIES FROM
 THE IMPACTS OF THE OUTDOOR STORAGE). THEREFORE, IF YOU
 WISH TO PROCEED WITH THE OUTDOOR VEHICLE STORAGE, YOU
 WILL NEED TO INCLUDE ADDITIONAL SCREENING ALONG THE
 PROPERTY LINES. [SATISFIED]
 6. THE FLARES OF YOUR ACCESS POINTS SEEM TO EXTEND PAST
 THE PROPERTY LINES AND IN FRONT OF ADJACENT PROPERTIES.
 THIS WILL NEED TO BE CORRECTED. [RESPONSE PROVIDED]
 7. PLEASE SHOW THAT THE VISIBILITY TRIANGLE
 REQUIREMENTS ARE MET AT THE ROW ACCESS POINTS PURSUANT
 TO SUBSECTION 94-305(E). [SATISFIED]
 8. THE ARROW IDENTIFYING THE BIKE RACK DOES NOT
 ACTUALLY POINT TO THE BIKE RACK. FURTHERMORE, THERE IS
 WHAT LOOKS TO BE A BIKE RACK AND CONCRETE PAD BELOW
 WHERE THE ARROW POINTS TO, IS THIS THE BIKE RACK? IF
 SO, THE BIKE RACK APPEARS TO BE FACING THE WRONG WAY.
 [SATISFIED]
 9. TWO BIKE PARKING SPACES ARE NEEDED TO REFLECT THE
 REQUIRED PARKING AS CITY CODE REQUIRES 1 BIKE SPACE FOR
 EVERY 20 PARKING SPACES OR PORTION THEREOF. [RESPONSE
 PROVIDED]
  
  
  
 - WHEN RESUBMITTING, PLEASE PROVIDE A MINIMUM OF THREE
 (3) PAPER COPIES AND AN ELECTRONIC COPY IN .PNG/.PDF
 FORMAT OF ALL PLANS. PLEASE NOTE THAT CHANGES ON THE
 RESUBMITTED PLANS OR THE SUBMITTAL OF INFORMATION/PLANS
 TO ADDRESS THE COMMENTS MAY RESULT IN ADDITIONAL
 COMMENTS.
  
 - THE PPRC COMMENTS SHALL BE SUFFICIENTLY ADDRESSED AND
 SUBMITTED TO THE PLANNING DIVISION BY 5 PM ON FRIDAY,
 09/23/22, TO BE ELIGIBLE TO BE SCHEDULED FOR THE
 11/15/22 PLANNING BOARD MEETING.
  
 - PLEASE NOTE THAT IF THE PLANNING DIVISION HAS NOT
 RECEIVED A RESPONSE TO THE PPRC COMMENTS/REVIEW
 COMMENTS WITHIN 60 DAYS FROM THE DATE OF THE PPRC
 MEETING/COMMENT ISSUANCE (BY 11/08/22), THE PLANNING
 DIVISION MAY NOTIFY THE APPLICANT THAT THE CASE IS
 CONSIDERED WITHDRAWN. ANY FURTHER ACTION SHALL REQUIRE
 A NEW DEVELOPMENT APPLICATION.
  
 - PLEASE NOTE THAT YOU WILL BE PERMITTED ONE (1)
 RESUBMITTAL AT NO ADDITIONAL COST. IF PREVIOUSLY ISSUED
 COMMENTS CONTINUE TO NOT BE SUFFICIENTLY ADDRESSED, THE
 APPLICANT WILL BE ASSESSED A RESUBMITTAL FEE. SUCH FEE
 WILL BE 20% OF THE ORIGINAL APPLICATION FEE.
  
 - PUBLIC HEARING NOTIFICATION SIGNAGE SHALL BE POSTED
 IN ACCORDANCE WITH THE REQUIREMENTS OF SECTION
 94-39(I)(5) OF THE ZONING AND LAND DEVELOPMENT
 REGULATIONS.
  
  
  
 ADDITIONAL REVIEW COMMENTS:
 10. PLEASE PROVIDE THE STANDARD OF COMPLIANCE RESPONSES
 TO THE APPLICABLE REQUIREMENTS OF THE CITY???S ZONING
 AND LAND DEVELOPMENT REGULATIONS (ZLDR) SECTION 94-207.
 [SATISFIED]
 11. PLEASE PROVIDE LETTERS FROM PUBLIC UTILITIES (AT&T
 TELECOMMUNICATION, FLORIDA PUBLIC UTILITIES, FLORIDA
 POWER & LIGHT COMPANY, AND COMCAST CABLE
 COMMUNICATIONS) CONFIRMING THAT THE PROPOSED PROJECT
 DOES NOT ENCROACH INTO THEIR EASEMENTS OR OTHERWISE
 INTERFERE WITH THE PROVISIONS OF THEIR SERVICES.
 [PARTIALLY SATISFIED]
 12. PLEASE PROVIDE A TRAFFIC CONCURRENCY/PERFORMANCE
 STANDARD REVIEW (TPS) LETTER FROM THE PALM BEACH COUNTY
 TRAFFIC DIVISION FOR THE SUBJECT PROJECT. [SATISFIED]
 13. PLEASE PROVIDE THE PROFESSIONAL CERTIFICATION
 LETTERS. [SATISFIED]
 14. PLEASE PROVIDE THE AGREEMENTS, PROVISIONS OR
 COVENANTS WHICH GOVERN THE USE, MAINTENANCE AND
 CONTINUED PROTECTION OF THE PD AND ANY OF ITS COMMON
 AREAS OR FACILITIES. [RESPONSE PROVIDED]
 15. PLEASE PROVIDE/INDICATE/DEMONSTRATE CONSISTENT
 INFORMATION ON ALL THE DIFFERENT PLANS AND REQUIRED
 MATERIALS WITHIN THE APPLICATION PACKET RESUBMITTAL.
 [SATISFIED]
 16. IN ACCORDANCE WITH THE CITY???S ZONING AND LAND
 DEVELOPMENT REGULATIONS (ZLDR) SUBSECTION
 94-207(B)(9)(A)(1), PLEASE IDENTIFY/INDICATE THE NAME
 OF THE DEVELOPER ON THE SITE PLANS, SHEETS SP-1 AND
 SP-2. [SATISFIED]
 17. PLEASE IDENTIFY/INDICATE THE PROPOSED OUTDOOR
 STORAGE USE IN THE SITE TABULAR DATA TABLE ON THE SITE
 PLANS, SHEETS SP-1 AND SP-2. [SATISFIED]
 18. PLEASE SUBMIT REVISED PLANS
 IDENTIFYING/INDICATING/DEMONSTRATING CONSISTENT
 INFORMATION REGARDING THE EXISTING AND PROPOSED PUBLIC
 SIDEWALK ALONG NORTH FLORIDA MANGO ROAD. [SATISFIED]
 19. IN ACCORDANCE WITH SECTION 94-243 OF THE ZLDR, THE
 MINIMUM LANDSCAPING AREA REQUIRED IS 20%. THEREFORE,
 PLEASE REVISE THE JUSTIFICATION STATEMENT AND PLANS,
 ACCORDINGLY. [SATISFIED]
 20. PLEASE CORRECT THE SITE TABULAR DATA TABLE ON THE
 SITE PLANS, SHEETS SP-1 AND SP-2, TO IDENTIFY/INDICATE
 THE NUMBER OF THE LOADING SPACES PROVIDED AS
 DEMONSTRATED IN THE GRAPHICS/PLANS. [SATISFIED]
 21. IN REFERENCE TO PREVIOUS REVIEW COMMENT 9., PLEASE
 CORRECT THE SITE TABULAR DATA TABLE ON THE SITE PLANS,
 SHEETS SP-1 AND SP-2, TO IDENTIFY/INDICATE THE NUMBER
 OF BICYCLE PARKING REQUIRED AND PROPOSED. [RESPONSE
 PROVIDED]
 22. PLEASE IDENTIFY/INDICATE/DEMONSTRATE THE HEIGHT AND
 SIZE OF THE EXISTING/PROPOSED MARQUE SIGN ON THE
 DIFFERENT PLANS, ACCORDINGLY. [SATISFIED]
 23. PLEASE IDENTIFY/INDICATE/DEMONSTRATE THE
 EXISTING/PROPOSED MARQUE SIGN SETBACK DIMENSION FROM
 PUBLIC RIGHT-OF-WAY LINE ON THE DIFFERENT PLANS
 ACCORDING TO SUBSECTION 94-408(D) OF THE ZLDR.
 [SATISFIED]
 24. PLEASE IDENTIFY/INDICATE/DEMONSTRATE THE LOCATION
 OF ALL PUBLIC ART PROPOSED ON THE DIFFERENT PLANS,
 ACCORDINGLY. [SATISFIED]
 25. PLEASE IDENTIFY/INDICATE/DEMONSTRATE THE EXISTING
 AND PROPOSED FIRE HYDRANTS (OR OPERATIONAL EQUIVALENTS)
 WITHIN 250 FEET OF THE PROPOSED STRUCTURE(S) ON THE
 DIFFERENT PLANS, ACCORDINGLY. [SATISFIED]
 26. PLEASE IDENTIFY/INDICATE/DEMONSTRATE THE LOCATION
 OF ANY SPECIAL UTILITY STRUCTURES SUCH AS VALVES,
 METERS, BACKFLOW CONNECTIONS, PUMP STATIONS,
 TRANSFORMERS, AND ALL ABOVE GROUND APPURTENANCES ON THE
 DIFFERENT PLANS, ACCORDINGLY. [SATISFIED]
 27. IN ORDER FOR THE SUBJECT CASE TO PROCEED THROUGH
 THE REVIEW PROCESS, AN APPROVAL OF THE PROPOSED CITY
 ZONING AND LAND DEVELOPMENT REGULATION TEXT AMENDMENT
 (CRC 22-11 / Z22120037) MUST BE OBTAINED. [RESPONSE
 PROVIDED]
 28. IN REFERENCE TO REVIEW COMMENT 11., IT HAS BEEN
 IDENTIFIED THAT THE LETTER FROM COMCAST CABLE
 COMMUNICATIONS REFERS TO A PROFESSIONAL MEDICAL OFFICE
 BUILDING. THEREFORE, PLEASE PROVIDE AN UPDATED LETTER
 FROM COMCAST CABLE COMMUNICATIONS.
  
  
 KEVIE DEFRANC
 SENIOR PLANNER - PLANNING DIVISION
 [email protected]
 561-822-1449
  

Review Stop Z ZONING
Rev No 3 Status F Date 04-04-2023 Cont ID  
Sent By kdefranc Date 04-04-2023 Time 17:20 Rev Time 0.00
Received By kdefranc Date 04-04-2023 Time 17:19 Sent To  
Notes
2023-04-04 17:20:264/4/23 ??? FAILED
  
  
 PREVIOUS REVIEW COMMENTS:
 1. PER CITY CODE, PARKING WAIVERS FOR PDS CAN ONLY BE
 GRANTED IF THE PROJECT IS LOCATED EAST OF INTERSTATE
 95, OR EAST OF AUSTRALIAN AVENUE BETWEEN OKEECHOBEE
 BOULEVARD AND BELVEDERE ROAD. THE SUBJECT PROPERTY DOES
 NOT FALL WITHIN THIS AREA, THEREFORE ALL PARKING AND
 LOADING SPACES SHALL BE PROVIDED PURSUANT TO ARTICLE XV
 OF THE ZONING AND LAND DEVELOPMENT REGULATIONS. [NOT
 SATISFIED - HOWEVER, SUBMITTED TEXT CHANGE (ZLDRS)
 APPLICATION ACKNOWLEDGED]
 2. PER ARTICLE XV, NUMBER OF PARKING SPACES WAS
 CALCULATED INCORRECTLY 33 TOTAL PARKING SPACES ARE
 NEEDED (3 FOR THE OFFICE SPACE, 5 FOR THE FIRST 10,000
 SQ FEET OF WAREHOUSE SPACE, 24.32 (ROUNDED UP TO 25)
 FOR THE REMAINING 98,292 SQ FEET OF WAREHOUSE SPACE.)
 [RESPONSE PROVIDED]
 3. THE SITE PLAN SHOWS OPPOSITE ONE-WAY ROADS TO THE
 NORTH AND SOUTH OF THE BUILDING, AND TWO WAY ROADS TO
 THE EAST AND WEST. THIS DOES NOT MAKE SENSE FROM A
 TRAFFIC FLOW PERSPECTIVE. [SATISFIED]
 4. PROVIDE A PHOTOMETRIC PLAN SHOWING COMPLIANCE WITH
 THE FOLLOWING STANDARD (ANY SOURCE OF ILLUMINATION
 LOCATED WITHIN A COMMERCIAL OR INDUSTRIAL PLANNED
 DEVELOPMENT DISTRICT SHALL NOT EXCEED ONE FOOTCANDLE AT
 OR BEYOND THE BOUNDARIES OF SUCH DEVELOPMENT.)
 [SATISFIED]
 5. NOTE THAT THE FOLLOWING CPD STANDARD (OUTDOOR
 STORAGE FACILITIES ARE PROHIBITED IN ANY COMMERCIAL
 PLANNED DEVELOPMENT DISTRICT, UNLESS OUTDOOR STORAGE IS
 EXPRESSLY APPROVED BY THE CITY COMMISSION AS PART OF
 THE ORDINANCE ADOPTING THE COMMERCIAL PLANNED
 DEVELOPMENT. APPROVAL OF OUTDOOR STORAGE IN A
 COMMERCIAL PLANNED DEVELOPMENT DISTRICT SHALL INCLUDE
 MITIGATION MEASURES TO PROTECT ADJACENT PROPERTIES FROM
 THE IMPACTS OF THE OUTDOOR STORAGE). THEREFORE, IF YOU
 WISH TO PROCEED WITH THE OUTDOOR VEHICLE STORAGE, YOU
 WILL NEED TO INCLUDE ADDITIONAL SCREENING ALONG THE
 PROPERTY LINES. [SATISFIED]
 6. THE FLARES OF YOUR ACCESS POINTS SEEM TO EXTEND PAST
 THE PROPERTY LINES AND IN FRONT OF ADJACENT PROPERTIES.
 THIS WILL NEED TO BE CORRECTED. [RESPONSE PROVIDED]
 7. PLEASE SHOW THAT THE VISIBILITY TRIANGLE
 REQUIREMENTS ARE MET AT THE ROW ACCESS POINTS PURSUANT
 TO SUBSECTION 94-305(E). [SATISFIED]
 8. THE ARROW IDENTIFYING THE BIKE RACK DOES NOT
 ACTUALLY POINT TO THE BIKE RACK. FURTHERMORE, THERE IS
 WHAT LOOKS TO BE A BIKE RACK AND CONCRETE PAD BELOW
 WHERE THE ARROW POINTS TO, IS THIS THE BIKE RACK? IF
 SO, THE BIKE RACK APPEARS TO BE FACING THE WRONG WAY.
 [SATISFIED]
 9. TWO BIKE PARKING SPACES ARE NEEDED TO REFLECT THE
 REQUIRED PARKING AS CITY CODE REQUIRES 1 BIKE SPACE FOR
 EVERY 20 PARKING SPACES OR PORTION THEREOF. [PARTIALLY
 SATISFIED]
  
  
  
 - WHEN RESUBMITTING, PLEASE PROVIDE A MINIMUM OF THREE
 (3) PAPER COPIES AND AN ELECTRONIC COPY IN .PNG/.PDF
 FORMAT OF ALL PLANS. PLEASE NOTE THAT CHANGES ON THE
 RESUBMITTED PLANS OR THE SUBMITTAL OF INFORMATION/PLANS
 TO ADDRESS THE COMMENTS MAY RESULT IN ADDITIONAL
 COMMENTS.
  
 - THE PPRC COMMENTS SHALL BE SUFFICIENTLY ADDRESSED AND
 SUBMITTED TO THE PLANNING DIVISION BY 5 PM ON FRIDAY,
 09/23/22, TO BE ELIGIBLE TO BE SCHEDULED FOR THE
 11/15/22 PLANNING BOARD MEETING.
  
 - PLEASE NOTE THAT IF THE PLANNING DIVISION HAS NOT
 RECEIVED A RESPONSE TO THE PPRC COMMENTS/REVIEW
 COMMENTS WITHIN 60 DAYS FROM THE DATE OF THE PPRC
 MEETING/COMMENT ISSUANCE (BY 11/08/22), THE PLANNING
 DIVISION MAY NOTIFY THE APPLICANT THAT THE CASE IS
 CONSIDERED WITHDRAWN. ANY FURTHER ACTION SHALL REQUIRE
 A NEW DEVELOPMENT APPLICATION.
  
 - PLEASE NOTE THAT YOU WILL BE PERMITTED ONE (1)
 RESUBMITTAL AT NO ADDITIONAL COST. IF PREVIOUSLY ISSUED
 COMMENTS CONTINUE TO NOT BE SUFFICIENTLY ADDRESSED, THE
 APPLICANT WILL BE ASSESSED A RESUBMITTAL FEE. SUCH FEE
 WILL BE 20% OF THE ORIGINAL APPLICATION FEE.
  
 - PUBLIC HEARING NOTIFICATION SIGNAGE SHALL BE POSTED
 IN ACCORDANCE WITH THE REQUIREMENTS OF SECTION
 94-39(I)(5) OF THE ZONING AND LAND DEVELOPMENT
 REGULATIONS.
  
  
  
 ADDITIONAL REVIEW COMMENTS:
 10. PLEASE PROVIDE THE STANDARD OF COMPLIANCE RESPONSES
 TO THE APPLICABLE REQUIREMENTS OF THE CITY???S ZONING
 AND LAND DEVELOPMENT REGULATIONS (ZLDR) SECTION 94-207.
 [SATISFIED]
 11. PLEASE PROVIDE LETTERS FROM PUBLIC UTILITIES (AT&T
 TELECOMMUNICATION, FLORIDA PUBLIC UTILITIES, FLORIDA
 POWER & LIGHT COMPANY, AND COMCAST CABLE
 COMMUNICATIONS) CONFIRMING THAT THE PROPOSED PROJECT
 DOES NOT ENCROACH INTO THEIR EASEMENTS OR OTHERWISE
 INTERFERE WITH THE PROVISIONS OF THEIR SERVICES. [NOT
 SATISFIED]
 12. PLEASE PROVIDE A TRAFFIC CONCURRENCY/PERFORMANCE
 STANDARD REVIEW (TPS) LETTER FROM THE PALM BEACH COUNTY
 TRAFFIC DIVISION FOR THE SUBJECT PROJECT. [SATISFIED]
 13. PLEASE PROVIDE THE PROFESSIONAL CERTIFICATION
 LETTERS. [SATISFIED]
 14. PLEASE PROVIDE THE AGREEMENTS, PROVISIONS OR
 COVENANTS WHICH GOVERN THE USE, MAINTENANCE AND
 CONTINUED PROTECTION OF THE PD AND ANY OF ITS COMMON
 AREAS OR FACILITIES. [RESPONSE PROVIDED]
 15. PLEASE PROVIDE/INDICATE/DEMONSTRATE CONSISTENT
 INFORMATION ON ALL THE DIFFERENT PLANS AND REQUIRED
 MATERIALS WITHIN THE APPLICATION PACKET RESUBMITTAL.
 [NOT SATISFIED]
 16. IN ACCORDANCE WITH THE CITY???S ZONING AND LAND
 DEVELOPMENT REGULATIONS (ZLDR) SUBSECTION
 94-207(B)(9)(A)(1), PLEASE IDENTIFY/INDICATE THE NAME
 OF THE DEVELOPER ON THE SITE PLANS, SHEETS SP-1 AND
 SP-2. [SATISFIED]
 17. PLEASE IDENTIFY/INDICATE THE PROPOSED OUTDOOR
 STORAGE USE IN THE SITE TABULAR DATA TABLE ON THE SITE
 PLANS, SHEETS SP-1 AND SP-2. [SATISFIED]
 18. PLEASE SUBMIT REVISED PLANS
 IDENTIFYING/INDICATING/DEMONSTRATING CONSISTENT
 INFORMATION REGARDING THE EXISTING AND PROPOSED PUBLIC
 SIDEWALK ALONG NORTH FLORIDA MANGO ROAD. [SATISFIED]
 19. IN ACCORDANCE WITH SECTION 94-243 OF THE ZLDR, THE
 MINIMUM LANDSCAPING AREA REQUIRED IS 20%. THEREFORE,
 PLEASE REVISE THE JUSTIFICATION STATEMENT AND PLANS,
 ACCORDINGLY. [PARTIALLY SATISFIED]
 20. PLEASE CORRECT THE SITE TABULAR DATA TABLE ON THE
 SITE PLANS, SHEETS SP-1 AND SP-2, TO IDENTIFY/INDICATE
 THE NUMBER OF THE LOADING SPACES PROVIDED AS
 DEMONSTRATED IN THE GRAPHICS/PLANS. [SATISFIED]
 21. IN REFERENCE TO PREVIOUS REVIEW COMMENT 9., PLEASE
 CORRECT THE SITE TABULAR DATA TABLE ON THE SITE PLANS,
 SHEETS SP-1 AND SP-2, TO IDENTIFY/INDICATE THE NUMBER
 OF BICYCLE PARKING REQUIRED AND PROPOSED. [PARTIALLY
 SATISFIED]
 22. PLEASE IDENTIFY/INDICATE/DEMONSTRATE THE HEIGHT AND
 SIZE OF THE EXISTING/PROPOSED MARQUE SIGN ON THE
 DIFFERENT PLANS, ACCORDINGLY. [SATISFIED]
 23. PLEASE IDENTIFY/INDICATE/DEMONSTRATE THE
 EXISTING/PROPOSED MARQUE SIGN SETBACK DIMENSION FROM
 PUBLIC RIGHT-OF-WAY LINE ON THE DIFFERENT PLANS
 ACCORDING TO SUBSECTION 94-408(D) OF THE ZLDR.
 [SATISFIED]
 24. PLEASE IDENTIFY/INDICATE/DEMONSTRATE THE LOCATION
 OF ALL PUBLIC ART PROPOSED ON THE DIFFERENT PLANS,
 ACCORDINGLY. [SATISFIED]
 25. PLEASE IDENTIFY/INDICATE/DEMONSTRATE THE EXISTING
 AND PROPOSED FIRE HYDRANTS (OR OPERATIONAL EQUIVALENTS)
 WITHIN 250 FEET OF THE PROPOSED STRUCTURE(S) ON THE
 DIFFERENT PLANS, ACCORDINGLY. [NOT SATISFIED]
 26. PLEASE IDENTIFY/INDICATE/DEMONSTRATE THE LOCATION
 OF ANY SPECIAL UTILITY STRUCTURES SUCH AS VALVES,
 METERS, BACKFLOW CONNECTIONS, PUMP STATIONS,
 TRANSFORMERS, AND ALL ABOVE GROUND APPURTENANCES ON THE
 DIFFERENT PLANS, ACCORDINGLY. [NOT SATISFIED]
 27. IN ORDER FOR THE SUBJECT CASE TO PROCEED THROUGH
 THE REVIEW PROCESS, AN APPROVAL OF THE PROPOSED CITY
 ZONING AND LAND DEVELOPMENT REGULATION TEXT AMENDMENT
 (CRC 22-11 / Z22120037) MUST BE OBTAINED.
  
  
 KEVIE DEFRANC
 SENIOR PLANNER - PLANNING DIVISION
 [email protected]
 561-822-1449
  

Review Stop Z ZONING
Rev No 2 Status F Date 01-23-2023 Cont ID  
Sent By kdefranc Date 01-23-2023 Time 12:55 Rev Time 0.00
Received By kdefranc Date 01-23-2023 Time 12:54 Sent To  
Notes
2023-01-23 12:54:581/23/23 ??? FAILED
  
  
 PREVIOUS REVIEW COMMENTS MUST BE ADDRESSED:
 1. PER CITY CODE, PARKING WAIVERS FOR PDS CAN ONLY BE
 GRANTED IF THE PROJECT IS LOCATED EAST OF INTERSTATE
 95, OR EAST OF AUSTRALIAN AVENUE BETWEEN OKEECHOBEE
 BOULEVARD AND BELVEDERE ROAD. THE SUBJECT PROPERTY DOES
 NOT FALL WITHIN THIS AREA, THEREFORE ALL PARKING AND
 LOADING SPACES SHALL BE PROVIDED PURSUANT TO ARTICLE XV
 OF THE ZONING AND LAND DEVELOPMENT REGULATIONS. [NOT
 SATISFIED - HOWEVER, SUBMITTED TEXT CHANGE (ZLDRS)
 APPLICATION ACKNOWLEDGED]
 2. PER ARTICLE XV, NUMBER OF PARKING SPACES WAS
 CALCULATED INCORRECTLY 33 TOTAL PARKING SPACES ARE
 NEEDED (3 FOR THE OFFICE SPACE, 5 FOR THE FIRST 10,000
 SQ FEET OF WAREHOUSE SPACE, 24.32 (ROUNDED UP TO 25)
 FOR THE REMAINING 98,292 SQ FEET OF WAREHOUSE SPACE.)
 [NOT SATISFIED]
 3. THE SITE PLAN SHOWS OPPOSITE ONE-WAY ROADS TO THE
 NORTH AND SOUTH OF THE BUILDING, AND TWO WAY ROADS TO
 THE EAST AND WEST. THIS DOES NOT MAKE SENSE FROM A
 TRAFFIC FLOW PERSPECTIVE. [SATISFIED]
 4. PROVIDE A PHOTOMETRIC PLAN SHOWING COMPLIANCE WITH
 THE FOLLOWING STANDARD (ANY SOURCE OF ILLUMINATION
 LOCATED WITHIN A COMMERCIAL OR INDUSTRIAL PLANNED
 DEVELOPMENT DISTRICT SHALL NOT EXCEED ONE FOOTCANDLE AT
 OR BEYOND THE BOUNDARIES OF SUCH DEVELOPMENT.) [NOT
 SATISFIED]
 5. NOTE THAT THE FOLLOWING CPD STANDARD (OUTDOOR
 STORAGE FACILITIES ARE PROHIBITED IN ANY COMMERCIAL
 PLANNED DEVELOPMENT DISTRICT, UNLESS OUTDOOR STORAGE IS
 EXPRESSLY APPROVED BY THE CITY COMMISSION AS PART OF
 THE ORDINANCE ADOPTING THE COMMERCIAL PLANNED
 DEVELOPMENT. APPROVAL OF OUTDOOR STORAGE IN A
 COMMERCIAL PLANNED DEVELOPMENT DISTRICT SHALL INCLUDE
 MITIGATION MEASURES TO PROTECT ADJACENT PROPERTIES FROM
 THE IMPACTS OF THE OUTDOOR STORAGE). THEREFORE, IF YOU
 WISH TO PROCEED WITH THE OUTDOOR VEHICLE STORAGE, YOU
 WILL NEED TO INCLUDE ADDITIONAL SCREENING ALONG THE
 PROPERTY LINES. [SATISFIED]
 6. THE FLARES OF YOUR ACCESS POINTS SEEM TO EXTEND PAST
 THE PROPERTY LINES AND IN FRONT OF ADJACENT PROPERTIES.
 THIS WILL NEED TO BE CORRECTED. [NOT SATISFIED]
 7. PLEASE SHOW THAT THE VISIBILITY TRIANGLE
 REQUIREMENTS ARE MET AT THE ROW ACCESS POINTS PURSUANT
 TO SUBSECTION 94-305(E). [SATISFIED]
 8. THE ARROW IDENTIFYING THE BIKE RACK DOES NOT
 ACTUALLY POINT TO THE BIKE RACK. FURTHERMORE, THERE IS
 WHAT LOOKS TO BE A BIKE RACK AND CONCRETE PAD BELOW
 WHERE THE ARROW POINTS TO, IS THIS THE BIKE RACK? IF
 SO, THE BIKE RACK APPEARS TO BE FACING THE WRONG WAY.
 [SATISFIED]
 9. TWO BIKE PARKING SPACES ARE NEEDED TO REFLECT THE
 REQUIRED PARKING AS CITY CODE REQUIRES 1 BIKE SPACE FOR
 EVERY 20 PARKING SPACES OR PORTION THEREOF. [PARTIALLY
 SATISFIED]
  
  
  
 - WHEN RESUBMITTING, PLEASE PROVIDE A MINIMUM OF THREE
 (3) PAPER COPIES AND AN ELECTRONIC COPY IN .PNG/.PDF
 FORMAT OF ALL PLANS. PLEASE NOTE THAT CHANGES ON THE
 RESUBMITTED PLANS OR THE SUBMITTAL OF INFORMATION/PLANS
 TO ADDRESS THE COMMENTS MAY RESULT IN ADDITIONAL
 COMMENTS.
  
 - THE PPRC COMMENTS SHALL BE SUFFICIENTLY ADDRESSED AND
 SUBMITTED TO THE PLANNING DIVISION BY 5 PM ON FRIDAY,
 09/23/22, TO BE ELIGIBLE TO BE SCHEDULED FOR THE
 11/15/22 PLANNING BOARD MEETING.
  
 - PLEASE NOTE THAT IF THE PLANNING DIVISION HAS NOT
 RECEIVED A RESPONSE TO THE PPRC COMMENTS/REVIEW
 COMMENTS WITHIN 60 DAYS FROM THE DATE OF THE PPRC
 MEETING/COMMENT ISSUANCE (BY 11/08/22), THE PLANNING
 DIVISION MAY NOTIFY THE APPLICANT THAT THE CASE IS
 CONSIDERED WITHDRAWN. ANY FURTHER ACTION SHALL REQUIRE
 A NEW DEVELOPMENT APPLICATION.
  
 - PLEASE NOTE THAT YOU WILL BE PERMITTED ONE (1)
 RESUBMITTAL AT NO ADDITIONAL COST. IF PREVIOUSLY ISSUED
 COMMENTS CONTINUE TO NOT BE SUFFICIENTLY ADDRESSED, THE
 APPLICANT WILL BE ASSESSED A RESUBMITTAL FEE. SUCH FEE
 WILL BE 20% OF THE ORIGINAL APPLICATION FEE.
  
 - PUBLIC HEARING NOTIFICATION SIGNAGE SHALL BE POSTED
 IN ACCORDANCE WITH THE REQUIREMENTS OF SECTION
 94-39(I)(5) OF THE ZONING AND LAND DEVELOPMENT
 REGULATIONS.
  
  
  
 ADDITIONAL REVIEW COMMENTS MUST BE ADDRESSED:
 10. PLEASE PROVIDE THE STANDARD OF COMPLIANCE RESPONSES
 TO THE APPLICABLE REQUIREMENTS OF THE CITY???S ZONING
 AND LAND DEVELOPMENT REGULATIONS (ZLDR) SECTION 94-207.
 11. PLEASE PROVIDE LETTERS FROM PUBLIC UTILITIES (AT&T
 TELECOMMUNICATION, FLORIDA PUBLIC UTILITIES, FLORIDA
 POWER & LIGHT COMPANY, AND COMCAST CABLE
 COMMUNICATIONS) CONFIRMING THAT THE PROPOSED PROJECT
 DOES NOT ENCROACH INTO THEIR EASEMENTS OR OTHERWISE
 INTERFERE WITH THE PROVISIONS OF THEIR SERVICES.
 12. PLEASE PROVIDE A TRAFFIC CONCURRENCY/PERFORMANCE
 STANDARD REVIEW (TPS) LETTER FROM THE PALM BEACH COUNTY
 TRAFFIC DIVISION FOR THE SUBJECT PROJECT.
 13. PLEASE PROVIDE THE PROFESSIONAL CERTIFICATION
 LETTERS.
 14. PLEASE PROVIDE THE AGREEMENTS, PROVISIONS OR
 COVENANTS WHICH GOVERN THE USE, MAINTENANCE AND
 CONTINUED PROTECTION OF THE PD AND ANY OF ITS COMMON
 AREAS OR FACILITIES.
 15. PLEASE PROVIDE/INDICATE/DEMONSTRATE CONSISTENT
 INFORMATION ON ALL THE DIFFERENT PLANS AND REQUIRED
 MATERIALS WITHIN THE APPLICATION PACKET RESUBMITTAL.
 16. IN ACCORDANCE WITH THE CITY???S ZONING AND LAND
 DEVELOPMENT REGULATIONS (ZLDR) SUBSECTION
 94-207(B)(9)(A)(1), PLEASE IDENTIFY/INDICATE THE NAME
 OF THE DEVELOPER ON THE SITE PLANS, SHEETS SP-1 AND
 SP-2.
 17. PLEASE IDENTIFY/INDICATE THE PROPOSED OUTDOOR
 STORAGE USE IN THE SITE TABULAR DATA TABLE ON THE SITE
 PLANS, SHEETS SP-1 AND SP-2.
 18. PLEASE SUBMIT REVISED PLANS
 IDENTIFYING/INDICATING/DEMONSTRATING CONSISTENT
 INFORMATION REGARDING THE EXISTING AND PROPOSED PUBLIC
 SIDEWALK ALONG NORTH FLORIDA MANGO ROAD.
 19. IN ACCORDANCE WITH SECTION 94-243 OF THE ZLDR, THE
 MINIMUM LANDSCAPING AREA REQUIRED IS 20%. THEREFORE,
 PLEASE REVISE THE JUSTIFICATION STATEMENT AND PLANS,
 ACCORDINGLY.
 20. PLEASE CORRECT THE SITE TABULAR DATA TABLE ON THE
 SITE PLANS, SHEETS SP-1 AND SP-2, TO IDENTIFY/INDICATE
 THE NUMBER OF THE LOADING SPACES PROVIDED AS
 DEMONSTRATED IN THE GRAPHICS/PLANS.
 21. IN REFERENCE TO PREVIOUS REVIEW COMMENT 9., PLEASE
 CORRECT THE SITE TABULAR DATA TABLE ON THE SITE PLANS,
 SHEETS SP-1 AND SP-2, TO IDENTIFY/INDICATE THE NUMBER
 OF BICYCLE PARKING REQUIRED AND PROPOSED.
 22. PLEASE IDENTIFY/INDICATE/DEMONSTRATE THE HEIGHT AND
 SIZE OF THE EXISTING/PROPOSED MARQUE SIGN ON THE
 DIFFERENT PLANS, ACCORDINGLY.
 23. PLEASE IDENTIFY/INDICATE/DEMONSTRATE THE
 EXISTING/PROPOSED MARQUE SIGN SETBACK DIMENSION FROM
 PUBLIC RIGHT-OF-WAY LINE ON THE DIFFERENT PLANS
 ACCORDING TO SUBSECTION 94-408(D) OF THE ZLDR.
 24. PLEASE IDENTIFY/INDICATE/DEMONSTRATE THE LOCATION
 OF ALL PUBLIC ART PROPOSED ON THE DIFFERENT PLANS,
 ACCORDINGLY.
 25. PLEASE IDENTIFY/INDICATE/DEMONSTRATE THE EXISTING
 AND PROPOSED FIRE HYDRANTS (OR OPERATIONAL EQUIVALENTS)
 WITHIN 250 FEET OF THE PROPOSED STRUCTURE(S) ON THE
 DIFFERENT PLANS, ACCORDINGLY.
 26. PLEASE IDENTIFY/INDICATE/DEMONSTRATE THE LOCATION
 OF ANY SPECIAL UTILITY STRUCTURES SUCH AS VALVES,
 METERS, BACKFLOW CONNECTIONS, PUMP STATIONS,
 TRANSFORMERS, AND ALL ABOVE GROUND APPURTENANCES ON THE
 DIFFERENT PLANS, ACCORDINGLY.
  
  
 KEVIE DEFRANC
 SENIOR PLANNER - PLANNING DIVISION
 [email protected]
 561-822-1449

Review Stop Z ZONING
Rev No 1 Status F Date 09-06-2022 Cont ID  
Sent By afowlkes Date 09-06-2022 Time 09:51 Rev Time 0.00
Received By afowlkes Date 09-06-2022 Time 09:51 Sent To  
Notes
2022-09-06 10:26:00CASE NO. PB 1937 (Z22080024)
 CASE NAME TROPICANA SELF STORAGE
 ADDRESS 2500 N FLORIDA MANGO RD
  
 - CONTACT ALEXANDER FOWLKES @ (561) 822-1446,
 [email protected]
  
 - PLEASE PROVIDE RESPONSES TO REVIEW COMMENTS IN
 WRITTEN FORMAT.
  
 1. PER CITY CODE, PARKING WAIVERS FOR PDS CAN ONLY BE
 GRANTED IF THE PROJECT IS LOCATED EAST OF INTERSTATE
 95, OR EAST OF AUSTRALIAN AVENUE BETWEEN OKEECHOBEE
 BOULEVARD AND BELVEDERE ROAD. THE SUBJECT PROPERTY DOES
 NOT FALL WITHIN THIS AREA, THEREFORE ALL PARKING AND
 LOADING SPACES SHALL BE PROVIDED PURSUANT TO ARTICLE XV
 OF THE ZONING AND LAND DEVELOPMENT REGULATIONS
 2. PER ARTICLE XV, NUMBER OF PARKING SPACES WAS
 CALCULATED INCORRECTLY 33 TOTAL PARKING SPACES ARE
 NEEDED ( 3 FOR THE OFFICE SPACE, 5 FOR THE FIRST 10,000
 SQ FEET OF WAREHOUSE SPACE, 24.32 (ROUNDED UP TO 25)
 FOR THE REMAINING 98,292 SQ FEET OF WAREHOUSE SPACE.)
 3. THE SITE PLAN SHOWS OPPOSITE ONE-WAY ROADS TO THE
 NORTH AND SOUTH OF THE BUILDING, AND TWO WAY ROADS TO
 THE EAST AND WEST. THIS DOES NOT MAKE SENSE FROM A
 TRAFFIC FLOW PERSPECTIVE
 4. PROVIDE A PHOTOMETRIC PLAN SHOWING COMPLIANCE WITH
 THE FOLLOWING STANDARD (ANY SOURCE OF ILLUMINATION
 LOCATED WITHIN A COMMERCIAL OR INDUSTRIAL PLANNED
 DEVELOPMENT DISTRICT SHALL NOT EXCEED ONE FOOTCANDLE AT
 OR BEYOND THE BOUNDARIES OF SUCH DEVELOPMENT.)
 5. NOTE THAT THE FOLLOWING CPD STANDARD (OUTDOOR
 STORAGE FACILITIES ARE PROHIBITED IN ANY COMMERCIAL
 PLANNED DEVELOPMENT DISTRICT, UNLESS OUTDOOR STORAGE IS
 EXPRESSLY APPROVED BY THE CITY COMMISSION AS PART OF
 THE ORDINANCE ADOPTING THE COMMERCIAL PLANNED
 DEVELOPMENT. APPROVAL OF OUTDOOR STORAGE IN A
 COMMERCIAL PLANNED DEVELOPMENT DISTRICT SHALL INCLUDE
 MITIGATION MEASURES TO PROTECT ADJACENT PROPERTIES FROM
 THE IMPACTS OF THE OUTDOOR STORAGE). THEREFORE, IF YOU
 WISH TO PROCEED WITH THE OUTDOOR VEHICLE STORAGE, YOU
 WILL NEED TO INCLUDE ADDITIONAL SCREENING ALONG THE
 PROPERTY LINES.
 6. THE FLARES OF YOUR ACCESS POINTS SEEM TO EXTEND PAST
 THE PROPERTY LINES AND IN FRONT OF ADJACENT PROPERTIES.
 THIS WILL NEED TO BE CORRECTED
 7. PLEASE SHOW THAT THE VISIBILITY TRIANGLE
 REQUIREMENTS ARE MET AT THE ROW ACCESS POINTS PURSUANT
 TO SUBSECTION 94-305(E).
 8. THE ARROW IDENTIFYING THE BIKE RACK DOES NOT
 ACTUALLY POINT TO THE BIKE RACK. FURTHERMORE, THERE IS
 WHAT LOOKS TO BE A BIKE RACK AND CONCRETE PAD BELOW
 WHERE THE ARROW POINTS TO, IS THIS THE BIKE RACK? IF
 SO, THE BIKE RACK APPEARS TO BE FACING THE WRONG WAY.
 9. TWO BIKE PARKING SPACES ARE NEEDED TO REFLECT THE
 REQUIRED PARKING AS CITY CODE REQUIRES 1 BIKE SPACE FOR
 EVERY 20 PARKING SPACES OR PORTION THEREOF.
  
  
  
 - WHEN RESUBMITTING, PLEASE PROVIDE A MINIMUM OF THREE
 (3) PAPER COPIES AND AN ELECTRONIC COPY IN .PNG/.PDF
 FORMAT OF ALL PLANS. PLEASE NOTE THAT CHANGES ON THE
 RESUBMITTED PLANS OR THE SUBMITTAL OF INFORMATION/PLANS
 TO ADDRESS THE COMMENTS MAY RESULT IN ADDITIONAL
 COMMENTS.
  
 - THE PPRC COMMENTS SHALL BE SUFFICIENTLY ADDRESSED AND
 SUBMITTED TO THE PLANNING DIVISION BY 5 PM ON FRIDAY,
 09/23/22, TO BE ELIGIBLE TO BE SCHEDULED FOR THE
 11/15/22 PLANNING BOARD MEETING.
  
 - PLEASE NOTE THAT IF THE PLANNING DIVISION HAS NOT
 RECEIVED A RESPONSE TO THE PPRC COMMENTS/REVIEW
 COMMENTS WITHIN 60 DAYS FROM THE DATE OF THE PPRC
 MEETING/COMMENT ISSUANCE (BY 11/08/22), THE PLANNING
 DIVISION MAY NOTIFY THE APPLICANT THAT THE CASE IS
 CONSIDERED WITHDRAWN. ANY FURTHER ACTION SHALL REQUIRE
 A NEW DEVELOPMENT APPLICATION.
  
 - PLEASE NOTE THAT YOU WILL BE PERMITTED ONE (1)
 RESUBMITTAL AT NO ADDITIONAL COST. IF PREVIOUSLY ISSUED
 COMMENTS CONTINUE TO NOT BE SUFFICIENTLY ADDRESSED, THE
 APPLICANT WILL BE ASSESSED A RESUBMITTAL FEE. SUCH FEE
 WILL BE 20% OF THE ORIGINAL APPLICATION FEE
  
 - PUBLIC HEARING NOTIFICATION SIGNAGE SHALL BE POSTED
 IN ACCORDANCE WITH THE REQUIREMENTS OF SECTION
 94-39(I)(5) OF THE ZONING AND LAND DEVELOPMENT
 REGULATIONS.
  