Plan Review Details - Project Z22080023
Plan Review Stops For Project Z22080023
Review Stop AIPP ART IN PUBLIC PLACES
Rev No 1 Status F Date 01-05-2023 Cont ID  
Sent By swelter Date 01-05-2023 Time 15:48 Rev Time 0.00
Received By swelter Date 01-05-2023 Time 16:01 Sent To  
Notes
2023-01-05 16:01:48AT THIS TIME OPTION 1 OR OPTION 2 MUST BE DETERMINED AS
 STATED ON THE APPLICATION. FURTHER, BASED ON MY
 ANALYSIS OF THE SITE PLAN I RECOMMEND THAT THE
 APPLICANT CHOOSE OPTION #2. IF AGREED UPON A FORMAL
 WRITTEN STATEMENT BE PROVIDED.
 A DECISION MUST BE MADE FOR SITE PLAN APPROVAL.
 OPTION 1 CLEARLY DEMONSTRATE ART ON SITE THAT DOES NOT
 CONFLICT WITH LANDSCAPING REQUIREMENTS AND ANY OTHER
 REGULATIONS.
 OPTION 2 A FORMAL WRITTEN STATEMENT ACKNOWLEDGING
 CONTRIBUTION INTO THE PUBLIC ART FUND.
 PLEASE FEEL FREE TO CONTACT AT [email protected] WITH
 ANY FURTHER QUESTIONS.
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 01-09-2023 Cont ID  
Sent By rbrown Date 01-09-2023 Time 15:18 Rev Time 0.00
Received By rbrown Date 01-09-2023 Time 15:18 Sent To  
Notes
2023-01-09 15:20:15DEVELOPMENT SERVICES DEPARTMENT, BUILDING DIVISION,
 COMMENTS:
  
 1. THIS REVIEW IS A CURSORY REVIEW AS IT RELATES TO THE
 SITE. IT IS NOT A REVIEW FOR FULL COMPLIANCE WITH
 FLORIDA BUILDING CODE. THE FOLLOWING COMMENTS ARE TO BE
 ADDRESSED FOR THE BUILDING PERMIT APPLICATION.
  
 2. BUILDING LOCATION RELATIVE TO THE PROPERTY LINE AND
 OTHER STRUCTURES. WHEN SUBMITTED FOR BUILDING PERMIT,
 COMPLIANCE WITH ALL BUILDING SEPARATION, PERCENTAGE OF
 OPENINGS AND OPENING PROTECTIVE REQUIREMENTS OF
 CHAPTERS 6 AND 7 OF THE FLORIDA BUILDING CODE SHALL BE
 VERIFIED.
  
 3. ENCLOSED PARKING GARAGES. IF THE PARKING GARAGE DOES
 NOT HAVE WALL OPENINGS, OR SUFFICIENT WALL OPENINGS TO
 MEET THE DEFINITION OF AN OPEN PARKING GARAGE, IT WILL
 BE CONSIDERED AN ENCLOSED PARKING GARAGE AND MUST HAVE
 EXHAUST SYSTEMS. THE EXHAUST SYSTEMS SHALL BE DESIGNED
 TO MINIMIZE NOISE LEVELS USING INLINE FAN SILENCERS OR
 OTHER APPROVED METHODS.
  
 4. GREASE INTERCEPTOR. A GREASE INTERCEPTOR WILL BE
 REQUIRED. FOR INFORMATION ON THE REQUIRED TYPE, SIZE
 AND LOCATION, PLEASE CONTACT RYAN BROWN, CHIEF PLUMBING
 INSPECTOR, DEVELOPMENT SERVICES DEPARTMENT, AT (561)
 805-6692, OR BY EMAIL: [email protected]
  
 5. SEPARATE PERMITS REQUIRED. ALL APPLICABLE PERMITS
 AND SUB-PERMITS MUST BE OBTAINED BEFORE COMMENCING THE
 WORK. SEPARATE PERMITS, PLANS AND FEES, ARE REQUIRED
 FOR SIGNS, SWIMMING POOLS AND SPAS, GAS SYSTEMS,
 GENERATORS, FIRE ALARM SYSTEMS, FIRE SPRINKLER AND
 OTHER FIRE SUPPRESSION SYSTEMS, GREASE INTERCEPTORS,
 SITE LIGHTING, SITE LANDSCAPE, SITE IRRIGATION, ETC.
  
 6. CONTRACTOR VEHICLE PARKING. PROPERTY OWNER AND
 CONTRACTOR SHALL MAKE ARRANGEMENTS FOR PARKING OF
 CONTRACTOR VEHICLES TO MINIMIZE THE IMPACT ON ALL
 NEIGHBORING PROPERTIES.
  
 7. PROTECTION OF NEIGHBORING PROPERTY. PROPERTY OWNER
 AND CONTRACTOR SHALL PROTECT ALL NEIGHBORING PROPERTY,
 INCLUDING VEHICLES, FROM DAMAGE OR DIRT CAUSED BY THE
 CONSTRUCTION, AND SHALL NOTIFY THE OCCUPANTS OF
 NEIGHBORING PROPERTIES ABOUT ALL STAGES OF CONSTRUCTION
 THAT MAY AFFECT THE USE OF THEIR PROPERTY.
  
 8. BUILDING ADDRESS. EACH SEPARATE BUILDING, AND UNIT
 WITH AN INDEPENDENT ENTRANCE FROM THE STREET, SHALL
 HAVE A SEPARATE ADDRESS ASSIGNED BASED ON THE LOCATION
 OF THE BUILDING ENTRANCE. FOR STREET ADDRESSING,
 CONTACT CAROLINE PUELL, ADDRESSING COORDINATOR, AT
 (561) 805 6659, OR BY EMAIL: [email protected]
  
 9. ART IN PUBLIC PLACES. THIS PROJECT WILL BE SUBJECT
 TO ART LIFE ASSESSMENT UNDER THE CITY OF WEST PALM
 BEACH ART IN PUBLIC PLACES (AIPP) PROGRAM. FOR ADVICE
 ON THE PROVISION OF PUBLIC ARTWORK IN LIEU OF THE AIPP
 ASSESSMENT, CONTACT SYBILLE WELTER, ART IN PUBLIC
 PLACES COORDINATOR, AT (561) 822-1521, OR BY EMAIL:
 [email protected]
  
 ROBERT BROWN
 BUILDING OFFICIAL
 TEL: 561 805 6652
 EMAIL: [email protected]
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 09-07-2022 Cont ID  
Sent By rbrown Date 09-07-2022 Time 14:51 Rev Time 0.00
Received By rrossano Date 09-07-2022 Time 14:51 Sent To  
Notes
2022-09-07 15:11:33DEVELOPMENT SERVICES DEPARTMENT, BUILDING DIVISION,
 COMMENTS:
  
 1. THIS REVIEW IS A CURSORY REVIEW AS IT RELATES TO THE
 SITE. IT IS NOT A REVIEW FOR FULL COMPLIANCE WITH
 FLORIDA BUILDING CODE. THE FOLLOWING COMMENTS ARE TO BE
 ADDRESSED FOR THE BUILDING PERMIT APPLICATION.
  
 2. UNITY OF TITLE. FOR ANY BUILDING CROSSING A PROPERTY
 LINE, EITHER A RECORDED UNITY OF TITLE, OR SOME OTHER
 APPROVED LEGAL INSTRUMENT, SHALL BE INCLUDED WITH THE
 PERMIT APPLICATION, OR THE BUILDING MUST HAVE A FIRE
 WALL ALONG THE PROPERTY LINE, PER SECTION 202 OF
 FLORIDA BUILDING CODE, BUILDING, FIRE SEPARATION
 DISTANCE.
  
 3. EXIT DISCHARGE FROM STAIRS. SHEET A1.01,
 GROUND/LOBBY LEVEL PLAN, SHOWS 4 OF THE 5 STAIRS
 DISCHARGING IN THE VALET FROP OFF OR LOADING AREA WITH
 NO EXTERIOR WALKWAY ACCESS TO THE STREET. PER SECTION
 1028.5 OF FLORIDA BUILDING CODE THE EXIT DISCHARGE
 SHALL PROVIDE DIRECT AND UNOBSTRUCTED ACCESS TO A
 PUBLIC WAY.
  
 4. EGRESS FROM THEATER LOBBY AND CINEMA SCREEN ROOMS.
 SHEET A1.02, THEATER LEVEL PLAN, DOES NOT SHOW ACCESS
 TO AT LEAST 2 STAIRWAYS SERVING THE THEATER LOBBY AND
 HOW THE STAIRWAYS WOULD PROVIDE ACCESS TO EXIT DOORS AT
 GRADE LEVEL. ALSO, THE SECOND EXIT ROUTE FROM EACH
 CINEMA SCREEN ROOM IS NOT SHOWN WITH ACCESS TO A
 STAIRWAY. PER SECTION 1006.2 OF FLORIDA BUILDING CODE
 AT LEAST 2 EXITS ARE REQUIRED.
  
 5. NUMBER OF ACCESSIBLE PARKING SPACES. THE PLANS DO
 NOT SHOW ANY ACCESSIBLE PARKING SPACES. THE MINIMUM
 NUMBER OF ACCESSIBLE PARKING SPACES PROVIDED SHALL BE
 IN ACCORDANCE WITH SECTION 208.2 OF FLORIDA
 ACCESSIBILITY CODE.
  
 6. LOCATION OF ACCESSIBLE PARKING SPACES. THE PLANS DO
 NOT SHOW ANY ACCESSIBLE PARKING SPACES. PER SECTION
 208.3 OF FLORIDA ACCESSIBILITY CODE, ACCESSIBLE PARKING
 SPACES ARE TO BE LOCATED ON THE SHORTEST POSSIBLE ROUTE
 OF TRAVEL FROM ADJACENT PARKING TO AN ACCESSIBLE
 ENTRANCE. THE DESIGN OF ACCESSIBLE PARKING SPACES SHALL
 COMPLY WITH SECTION 502 OF FLORIDA ACCESSIBILITY CODE
  
 7. VAN ACCESSIBLE PARKING SPACES. THE PLANS DO NOT SHOW
 ANY VAN ACCESSIBLE PARKING SPACES. PER SECTION 208.2.4
 OF FLORIDA ACCESSIBILITY CODE, ONE IN EVERY SIX
 REQUIRED ACCESSIBLE SPACES (AT LEAST ONE) IN A PARKING
 STRUCTURE, SHALL BE ?VAN ACCESSIBLE? AND DESIGNED IN
 ACCORDANCE WITH SECTION OF 502 OF FLORIDA ACCESSIBILITY
 CODE (VERTICAL CLEARANCE NOT LESS THAN 98 INCHES AT
 SPACE AND VEHICULAR ACCESS ROUTE)
  
 8. ELECTRIC VEHICLE CHARGING STATION. IF ELECTRIC
 VEHICLE (EV) CHARGING STATIONS ARE PROVIDED AT LEAST 1
 IN 25 MUST COMPLY WITH ACCESSIBLE PARKING SPACE
 REQUIREMENTS.
  
 9. BUILDING SIZE. WHEN SUBMITTED FOR BUILDING PERMIT,
 THE PLANS SHALL SHOW THAT THE TYPE OF CONSTRUCTION FOR
 THE BUILDINGS WILL BE IN ACCORDANCE WITH THE HEIGHT,
 AREA AND OCCUPANCY LIMITATIONS IN CHAPTER 5 OF THE
 FLORIDA BUILDING CODE.
  
 10. BUILDING LOCATION RELATIVE TO THE PROPERTY LINE AND
 OTHER STRUCTURES. WHEN SUBMITTED FOR BUILDING PERMIT,
 COMPLIANCE WITH ALL BUILDING SEPARATION, PERCENTAGE OF
 OPENINGS AND OPENING PROTECTIVE REQUIREMENTS OF
 CHAPTERS 6 AND 7 OF THE FLORIDA BUILDING CODE SHALL BE
 VERIFIED.
  
 11. ENCLOSED PARKING GARAGES. IF THE PARKING GARAGE
 DOES NOT HAVE WALL OPENINGS, OR SUFFICIENT WALL
 OPENINGS TO MEET THE DEFINITION OF AN OPEN PARKING
 GARAGE, IT WILL BE CONSIDERED AN ENCLOSED PARKING
 GARAGE AND MUST HAVE EXHAUST SYSTEMS. THE EXHAUST
 SYSTEMS SHALL BE DESIGNED TO MINIMIZE NOISE LEVELS
 USING INLINE FAN SILENCERS OR OTHER APPROVED METHODS.
  
 12. GREASE INTERCEPTOR. A GREASE INTERCEPTOR WILL BE
 REQUIRED. FOR INFORMATION ON THE REQUIRED TYPE, SIZE
 AND LOCATION, PLEASE CONTACT RYAN BROWN, CHIEF PLUMBING
 INSPECTOR, DEVELOPMENT SERVICES DEPARTMENT, AT (561)
 805-6692, OR BY EMAIL: [email protected]
  
 13. SEPARATE PERMITS REQUIRED. ALL APPLICABLE PERMITS
 AND SUB-PERMITS MUST BE OBTAINED BEFORE COMMENCING THE
 WORK. SEPARATE PERMITS, PLANS AND FEES, ARE REQUIRED
 FOR SIGNS, SWIMMING POOLS AND SPAS, GAS SYSTEMS,
 GENERATORS, FIRE ALARM SYSTEMS, FIRE SPRINKLER AND
 OTHER FIRE SUPPRESSION SYSTEMS, GREASE INTERCEPTORS,
 SITE LIGHTING, SITE LANDSCAPE, SITE IRRIGATION, ETC.
  
 14. CONTRACTOR VEHICLE PARKING. PROPERTY OWNER AND
 CONTRACTOR SHALL MAKE ARRANGEMENTS FOR PARKING OF
 CONTRACTOR VEHICLES TO MINIMIZE THE IMPACT ON ALL
 NEIGHBORING PROPERTIES.
  
 15. PROTECTION OF NEIGHBORING PROPERTY. PROPERTY OWNER
 AND CONTRACTOR SHALL PROTECT ALL NEIGHBORING PROPERTY,
 INCLUDING VEHICLES, FROM DAMAGE OR DIRT CAUSED BY THE
 CONSTRUCTION, AND SHALL NOTIFY THE OCCUPANTS OF
 NEIGHBORING PROPERTIES ABOUT ALL STAGES OF CONSTRUCTION
 THAT MAY AFFECT THE USE OF THEIR PROPERTY.
  
 16. BUILDING ADDRESS. EACH SEPARATE BUILDING, AND UNIT
 WITH AN INDEPENDENT ENTRANCE FROM THE STREET, SHALL
 HAVE A SEPARATE ADDRESS ASSIGNED BASED ON THE LOCATION
 OF THE BUILDING ENTRANCE. FOR STREET ADDRESSING,
 CONTACT CAROLINE PUELL, ADDRESSING COORDINATOR, AT
 (561) 805 6659, OR BY EMAIL: [email protected]
  
 17. ART IN PUBLIC PLACES. THIS PROJECT WILL BE SUBJECT
 TO ART LIFE ASSESSMENT UNDER THE CITY OF WEST PALM
 BEACH ART IN PUBLIC PLACES (AIPP) PROGRAM. FOR ADVICE
 ON THE PROVISION OF PUBLIC ARTWORK IN LIEU OF THE AIPP
 ASSESSMENT, CONTACT SYBILLE WELTER, ART IN PUBLIC
 PLACES COORDINATOR, AT (561) 822-1521, OR BY EMAIL:
 [email protected]
  
 ROBERT BROWN
 BUILDING OFFICIAL
 TEL: 561 805 6652
 EMAIL: [email protected]
  

Review Stop ENG - PPRC ENGINEERING - PPRC
Rev No 2 Status P Date 11-29-2022 Cont ID  
Sent By rrossano Date 11-29-2022 Time   Rev Time 0.00
Received By rrossano Date 11-29-2022 Time   Sent To  
Notes
***NONE***

Review Stop ENG - PPRC ENGINEERING - PPRC
Rev No 1 Status F Date 08-23-2022 Cont ID  
Sent By rrossano Date 08-23-2022 Time   Rev Time  
Received By rrossano Date 08-23-2022 Time   Sent To  
Notes
2022-08-23 14:11:44Z22080023 - FLAMINGO & DIXIE - REZON. MIXED USE 8.22.22
 REVIEW
 COMMENTS FOR CIVIL SUBMITTAL FROM RICK ROSSANO, SR.
 PROJECT COORD., ENG. SERVICES AT 561-494-1098
 [email protected]
 GENERAL:
 O PLEASE RESPOND TO ALL COMMENTS IN WRITING, AND
 INCLUDE PROJECT NAME, ADDRESS AND PERMIT NUMBER
 (Z-XXXXXXXX).
 O THE CITY OF WEST PALM BEACH HAS A NUMBER OF
 REGULATIONS AND PERMIT REQUIREMENTS WHICH DIRECTLY
 AFFECT THE DEVELOPMENT AND INSTALLATION OF WATER AND
 WASTEWATER UTILITIES WITHIN THE CITY. PLEASE SEE
 DEVELOPMENT PERMIT SUBMITTAL REQUIREMENTS AT THE LINK
 BELOW:
 A. HTTP://WPB.ORG/CMSPAGES/GETAMAZONFILE.ASPX?PATH=~\WP
 B_WEBSITE\MEDIA\ENGINEERING\DEVELOPMENT-APPLICATION-FUL
 L-PACKAGE_2016.PDF&HASH=7BD4DD7EB6115181D8C5977BCC02A97
 B1960045731D3658206F27451722716EF
 B. THIS AND OTHER RELATED ENGINEERING DOCUMENTS CAN BE
 FOUND HERE:
 HTTP://WPB.ORG/DEPARTMENTS/ENGINEERING-PUBLIC-WORKS/FOR
 MS,-PERMITS-APPLICATIONS
 C. ALSO SEE: CODE OF ORDINANCES, CITY OF WEST PALM
 BEACH, FLORIDA, CODIFIED THROUGH ORD. NO. 4183-08,
 ADOPTED SEPT. 22, 2008. (SUPPLEMENT NO. 18)
 CHAPTER 90 UTILITIES, ARTICLE I. IN GENERAL,
 SEC. 90-7. POLICY REGARDING EXTENSION OF WATER OR SEWER
 SERVICE FACILITIES OF THE CITY.
 THE WATER AND WASTEWATER SERVICE AGREEMENTS AND THE
 CONSTRUCTION PERMITS ADDRESS RESERVATION OF CAPACITY
 BASED ON USAGE, METER SIZE AND FEES, DESIGN STANDARDS,
 BACKFLOW PREVENTION, FIRE SERVICE AND IRRIGATION.
 O AS OF DECEMBER 20, 2015, THE CITY OF WEST PALM BEACH
 CROSS-CONNECTION CONTROL MANUAL HAS BEEN REVISED,
 STATING "ALL BACKFLOW DEVICES MUST BE LEAD-FREE". FOR
 MORE INFORMATION, REFER TO THE LINK BELOW:
 A. HTTP://WPB.ORG/DEPARTMENTS/PUBLIC-UTILITIES/FORMS-PU
 BLICATIONS/BACKFLOW-CROSS-CONNECTION- CONTROL-MANUAL
 O PLEASE SUBMIT A FORMAL AS-BUILT REQUEST FOR ALL CITY
 OF WEST PALM BEACH-OWNED UTILITIES WITHIN THE PUBLIC
 RIGHT OF WAY FOR THE ENTIRE EXTENT OF THE LIMITS OF
 YOUR PROJECT. IDENTIFY TYPE OF UTILITY, LOCATION, PIPE
 MATERIAL, AGE AND SIZE. PLEASE CONTACT JANICE TARBILL
 IN THE WPB ENGINEERING SERVICES DEPARTMENT AT
 [email protected] OR 561-494-1079 FOR FURTHER
 ASSISTANCE. NOTE THAT FIELD RECORDS ARE FOR INFORMATION
 ONLY. FIELD VERIFY UTILITY LOCATIONS USING FIELD
 SURVEY, POT-HOLING, SOFT DIGS ETC.
 O PROVIDE EXISTING AND PROPOSED PERVIOUS AND IMPERVIOUS
 DATA.
  
 BACKFLOW ASSEMBLY AND METERS:
 O SHOW AND LABEL ANY EXISTING OR PROPOSED WATER
 SERVICES AND WATER METERS, ALONG WITH WHAT IS HAPPENING
 TO THEM.
 O SHOW EXISTING AND PROPOSED DEDICATED UTILITY
 EASEMENTS TO ALLOW ACCESS FOR CITY PERSONNEL TO
 PROPOSED UTILITY WATER METERS. VERIFY THAT THERE ARE NO
 STRUCTURES WITHIN EASEMENT.
 O PROVIDE ENLARGED VIEW ON PLANS OF PROPOSED LOCATION
 OF WATER METER AND BACKFLOW
 PREVENTION.
 O BACKFLOWS SHALL BE INSTALLED ON PRIVATE PROPERTY
 OUTSIDE OF EASEMENTS AND RIGHTS OF WAY. DOMESTIC WATER
 METERS SHALL BE INSTALLED IMMEDIATELY ADJACENT TO
 PROPERTY LINE. 3 INCH AND LARGER WATER METERS SHALL BE
 INSTALLED ABOVE-GROUND ONLY.
 O CALLOUT DOMESTIC BACKFLOW PREVENTER AS RPPA (MAKE
 NOTE USC APPROVED) AND FIRE BACKFLOW PREVENTER AS DCDA.
  
 WATER/WASTEWATER PLAN:
 O PROVIDE VERTICAL DATUM AND DATUM CONVERSION
 INFORMATION (NAVD 1988 AND NGVD 1929).
 O SHOW PROJECT ADDRESS ON ALL PLAN SHEETS.
 O PROVIDE LEGEND ON ALL PLAN SHEETS TO INCLUDE
 STREETLIGHT, SIGN POSTS, TRANSFORMER BOXES ETC.
 O PLANS SHALL SHOW EXISTING AND PROPOSED LOCATIONS AND
 DIMENSIONS OF ALL WATER, STORMWATER, AND SANITARY AND
 SEWER LINES AND CLEANOUTS, INCLUDING STUBS TO EACH
 PROPERTY LINE FOR WATER AND SANITARY SEWERS, THE MAKE
 AND MODEL OF ALL VALVES, POTABLE AND IRRIGATION METERS,
 BACKFLOWS, FIRE HYDRANTS AND FDCS, AND OTHER DEVICES TO
 BE INSTALLED ON THE SYSTEM, CATCH BASINS, CULVERTS,
 DITCHES INCLUDING GRADES, PIPES SIZES, MATERIALS,
 ELEVATIONS, ASSUMPTIONS, CALCULATIONS, INVERT
 ELEVATIONS FOR ALL INLETS AND MANHOLES AND PROFILES OF
 SANITARY SEWER LINES.
 O GATE VALVE BOXES SHALL NOT BE INSTALLED IN CURB OR
 SIDEWALK. ALL AVAILABLE ELEVATION SHALL BE SHOWN ON THE
 PROFILE VIEW.
 O DIRECTION OF FLOW SHALL BE SHOWN ON PLAN VIEW ON PLAN
 VIEW FOR ALL SANITARY AND STORM SEWERS.
 O SHOW SLOPE % ON ALL SANITARY LINES AND CALL OUT
 MATERIAL.
 O PLAN VIEW SHALL SHOW ALL EXISTING AND PROPOSED
 UNDERGROUND UTILITY LAYOUT, INCLUDING FIBER OPTIC,
 ELECTRIC, GAS, AND CABLEVISION & TELECOMMUNICATION
 FACILITIES INCLUDING PIPE SIZE AND MATERIAL LOCATED IN
 THE RIGHT-OF-WAY.
 O PROVIDE PROFILE AND CLEARANCES BETWEEN WATER, SEWER
 AND STORM LINES PER CITY OF WEST PALM BEACH STANDARD
 DETAIL GN-2 SERIES, AT ALL UTILITY CROSSINGS. PLEASE
 INCLUDE FIBER OPTIC, ELECTRIC, GAS, AND CABLEVISION &
 TELECOMMUNICATION FACILITIES INCLUDING PIPE SIZE AND
 MATERIAL LOCATED IN THE RIGHT-OF-WAY.
 O SUBMIT COMPLETED LOS ANALYSIS SUMMARY TABLE DIRECTLY
 TO ENGINEERING (SHEET 33 OF CITY OF WPB DEVELOPMENT
 APPLICATION). PROVIDE CALCULATIONS ON PLANS OF EXISTING
 AND PROPOSED DEMANDS FOR WATER & SEWER (AVERAGE,
 MAXIMUM AND PEAK) AND FIRE FLOW DEMANDS. CALCULATIONS
 SHALL BE PER FAC 64E-6 FOR SEWER AND PER FAC 64-E.008
 FOR WATER.
 O PROVIDE FIRE FLOW TEST DATA.
 O CUT AND CAP UTILITIES NOT IN USE AND REMOVE ANY
 ABANDONED UTILITY LINES LARGER THAN 2 INCHES FROM CITY
 ROW.
 O WHEN PROPOSED, WATER MAINS IN CITY RIGHT OF WAY SHALL
 BE MADE OF DUCTILE IRON PIPE (NOT PVC) AND SPECIFY
 PROPOSED LENGTH IN FEET.
 O CHECK TO SEE IF FDEP FORMS FOR PROPOSED SANITARY
 SEWER ARE REQUIRED.
 O PROVIDE CLEANOUTS FOR PROPOSED SANITARY LINE ONSITE
 JUST INSIDE PROPERTY LINE, AT JOINTS AND EVERY 75 FEET.
 O ADD NOTE TO PLANS SPECIFYING CITY?S DOWNSTREAM LIFT
 STATION NUMBER.
 O PROVIDE ONSITE CLEANOUTS NEAR PROPERTY LINE FOR
 PROPOSED SANITARY LATERALS.
 O LABEL WATER LINES AS PRIVATE WHERE APPLICABLE.
 O PLEASE SHOW AND LABEL EXISTING AND PROPOSED GREASE
 TRAPS (IF ANY).
 O PER CITY STANDARDS MAINTAIN MINIMUM DISTANCE BETWEEN
 OUTSIDE DIAMETER OF CITY PIPE AND ROOT BARRIER.
  
 FORMAL ENGINEERING REVIEW:
 O FOR FORMAL ENGINEERING SUBMITTAL, SFWMD ERP AND NPDES
 NOI REQUIREMENTS WILL BE ENFORCED.
 - AN NOI IS REQUIRED FOR PROJECTS THAT:
 - 1) DISTURB ONE OF MORE ACRES OF LAND OR DISTURB LESS
 THAN ON ACRE OF LAND BUT ARE PART OF A COMMON PLAN OF
 DEVELOPMENT OR SALE;
 - 2) DISCHARGE STORMWATER TO SURFACE WATERS OF THE
 STATE OR TO SURFACE WATERS OF THE STATE THROUGH A
 MUNICIPAL SEPARATE STORM SEWER SYSTEM (MS4).
 - THE SFWMD ERP CAN BE OBTAINED THROUGH A 10-2 SELF
 CERTIFICATION THROUGH FDEP OR AN ERP APPLICATION
 THROUGH SFWMD. EITHER WAY, THE DEVELOPER/ENGINEER SHALL
 SUBMIT A COPY OF THE ERP PERMIT OR FDEP ACKNOWLEDGEMENT
 OF THE 10-2 CERTIFICATION.
 O FOR FORMAL ENGINEERING SUBMITTAL, PLEASE PROVIDE
 EASEMENT FOR PLACEMENT OF PROPOSED WATER METERS.
 O FOR FORMAL ENGINEERING SUBMITTAL, PROVIDE PROFILES OF
 WATER AND SEWER AND SHOW ANY CROSSINGS/CONFLICTS.
 O FOR FORMAL ENGINEERING SUBMITTAL, WHEN SUBMITTING
 APPROVED MATERIALS LIST, PLEASE PROVIDE MATERIAL/CUT
 SHEETS FOR ALL PROPOSED BACKFLOW DEVICES SHOWING
 SPECIFIC MODEL NUMBER AND SPECIFYING USC APPROVED
 LEAD-FREE DESIGN.
 O FOR FORMAL ENGINEERING SUBMITTAL, IF SANITARY LINES
 ARE PROPOSED IN ROW PLEASE SHOW ADJACENT SANITARY
 LATERAL LOCATIONS AND SHOW ADDRESSES OF ADJACENT
 PARCELS.
 O FOR FORMAL ENGINEERING SUBMITTAL, IF WATER LINES ARE
 BEING REPLACED IN ROW, SHOW ADJACENT PARCEL ADDRESSES.
 O FOR FORMAL ENGINEERING SUBMITTAL, ADD NOTE TO PROVIDE
 50 FT. PAVEMENT RESTORATION TRANSITION ON EACH SIDE OF
 PROPOSED TRENCH IN CITY MAINTAINED ROADWAY AREAS PER
 CITY OF WPB STANDARD DETAIL GC-8.
 O FOR FORMAL ENGINEERING SUBMITTAL, PLEASE PROVIDE
 CALCULATIONS OF PERVIOUS AND IMPERVIOUS AREAS FOR
 PROPOSED IMPROVED AREAS.
  
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 08-29-2022 Cont ID  
Sent By pleduc Date 08-29-2022 Time   Rev Time 0.00
Received By pleduc Date 08-29-2022 Time 13:12 Sent To  
Notes
2022-08-29 13:21:27THE FOLLOWING COMMENTS WERE SUBMITTED BY PETER LEDUC,
 FIRE MARSHAL, BUREAU OF FIRE PREVENTION, WEST PALM
 BEACH FIRE DEPARTMENT.
  
 THIS REVIEW CAN ONLY BE CONSIDERED PRELIMINARY AS THE
 DRAWINGS THAT WERE REVIEWED WERE NOT COMPLETE.
 ADDITIONAL COMMENTS CAN BE EXPECTED WHEN FULL DRAWINGS
 ARE SUBMITTED FOR PERMIT.
  
 THE FIRE PREVENTION BUREAU HAS NO OBJECTIONS TO THE
 PROPOSED PROJECT. THE FOLLOWING COMMENTS ARE INTENDED
 TO PROVIDE GUIDANCE FOR BUILDING PLAN SUBMITTAL.
  
 1. CONSTRUCTION, DEMOLITION, AND RENOVATION TO COMPLY
 WITH NFPA 241. EXTRA ATTENTION SHALL BE GIVEN TO THE
 PERMITTING AND LOCATION OF CONSTRUCTION TRAILERS. A
 PERMIT IS REQUIRED FOR ANY CONSTRUCTION TRAILER RELATED
 TO THIS PROJECT. SEPARATION DISTANCES FROM MAIN
 STRUCTURES AS WELL AS OTHER TRAILERS SHALL BE CLOSELY
 MONITORED FOR THE REQUIREMENTS OF FIRE SPRINKLER
 PROTECTION.
  
 2. SITE ACCESS AND EXIT POINTS ARE TO BE CLEARLY
 IDENTIFIED AND MAINTAINED FOR EMERGENCY VEHICLES DURING
 ALL CONSTRUCTION ACTIVITIES.
  
 3. THE BUILDING ADDRESS SHALL BE CLEARLY VISIBLE FROM
 ALL ACCESS ROADWAYS, INCLUDING DURING CONSTRUCTION.
 ADDRESS NUMBERS SHALL CONTRAST WITH THEIR BACKGROUND
 AND SHALL NOT BE LESS THAN SIX (6) INCHES IN HEIGHT
 WITH A ONE (1) INCH STROKE FOR ALL BUILDINGS.
  
 4. DURING CONSTRUCTION, TRASH AND DEBRIS IS TO BE
 REMOVED FROM THE SITE DAILY OR MORE OFTEN TO REDUCE THE
 ACCUMULATION OF POTENTIAL LIFE AND FIRE SAFETY HAZARDS.
  
 5. THE CONSTRUCTION OF THE BUILDING(S) SHALL COMPLY
 WITH THE 7TH EDITION OF THE FLORIDA FIRE PREVENTION
 CODE, INCLUDING NFPA 1 & 101, AND ALL ASSOCIATED FIRE
 CODES.
  
 6. FOR PLAN REVIEW SUBMITTAL, PLEASE INCLUDE THE
 OCCUPANCY TYPE PER THE FLORIDA FIRE PREVENTION CODE.
  
 7. FOR PLAN REVIEW SUBMITTAL, PLEASE ENSURE THAT A FIRE
 LOAD CALCULATION IS INCLUDED, AND THAT ADEQUATE WATER
 SUPPLY IS EXISTING OR WILL BE PROVIDED.
  
 8. ALL EXISTING AND NEW FIRE HYDRANTS PLANNED FOR THIS
 DEVELOPMENT SHALL BE CLEARLY INDICATED AND IDENTIFIED
 ON THE PLAN AND CLOSELY COORDINATED WITH THE BUREAU OF
 FIRE PREVENTION.
  
 THE PROPOSED LOCATION OF THE FIRE HYDRANT AND FDC SHALL
 BE WITHIN 100' OF EACH OTHER AND CLOSELY COORDINATED
 WITH THE BUREAU OF FIRE PREVENTION.
  
 9. PROVIDE FOR A FIRE SPRINKLER AND/OR FIRE ALARM PER
 THE APPLICABLE OCCUPANCY CODE. FOR ANY LIFE SAFETY
 ENGINEERED SYSTEM, I.E FIRE SPRINKLER AND FIRE ALARM,
 ENSURE THEY COMPLY WITH THE REQUIREMENTS OF F.A.C. 61G
 AND SUBMITTED WITH THE MASTER PERMIT.
  
 9A. THE LOCATION OF ANY APPLICABLE DDCV AND FIRE LINE
 LOCATIONS SHALL MEET AND BE INSTALLED PER THE
 REQUIREMENTS OF NFPA 24 AND SHALL BE COORDINATED WITH
 THE OFFICE OF FIRE MARSHAL, THE CITY'S ENGINEERS
 OFFICE, THE LANDSCAPE PLANNER, AND THE CITY'S PLANNING
 AND ZONING OFFICE.
  
 10. COMPLETE LIFE SAFETY PLANS FOR THE OCCUPANCY SHALL
 BE PROVIDED THAT ILLUSTRATE OCCUPANT LOADS, TRAVEL
 DISTANCES, EXIT SEPARATION DISTANCES, COMMON PATHS OF
 TRAVEL, DEAD-END CORRIDORS, EXIT SIGNS, EMERGENCY
 LIGHTING, EXITS LEADING TO A PUBLIC WAY, FIRE
 EXTINGUISHER LOCATIONS, AND ALL FIRE SAFETY FEATURES
 AND EQUIPMENT.
  
 11. IT IS HIGHLY RECOMMENDED (REQUIRED WITH FIRE
 SPRINKLER SYSTEM) THAT A KNOX BOX WITH KEYS FOR ENTRY
 DOOR LOCKS BE PROVIDED FOR 24 HOUR EMERGENCY ACCESS.
  
 12. ALL NEW ELEVATORS SHALL CONFORM TO THE FIRE
 FIGHTER?S EMERGENCY OPERATIONS REQUIREMENTS OF ASME
 A17.1/CSA B44, SAFETY CODE FOR ELEVATORS.
  
 ANY BUILDING THAT IS MORE THAN THREE STORIES HIGH OR IN
 WHICH THE VERTICAL DISTANCE BETWEEN THE BOTTOM TERMINAL
 LANDING AND THE TOP TERMINAL LANDING EXCEEDS 25 FEET
 MUST BE CONSTRUCTED TO CONTAIN AT LEAST ONE PASSENGER
 ELEVATOR THAT IS OPERATIONAL AND WILL ACCOMMODATE AN
 AMBULANCE STRETCHER 76 INCHES LONG AND 24 INCHES WIDE
 IN THE HORIZONTAL POSITION.
  
 13. TWO-WAY RADIO COMMUNICATIONS ENHANCEMENT SYSTEMS.
  
 NFPA 1, CHAPTER 11, BUILDING SERVICES; 11.10 TWO-WAY
 RADIO ENHANCEMENT SERVICES.
  
 11.10.1 IN ALL NEW AND EXISTING BUILDINGS, MINIMUM
 RADIO SIGNAL STRENGTH FOR FIRE DEPARTMENT
 COMMUNICATIONS SHALL BE MAINTAINED AT A LEVEL
 DETERMINED BY THE AHJ.
  
 CONTACT WILL NEED TO BE MADE TO MARK FILLA, PALM BEACH
 COUNTY PUBLIC SAFETY RADIO SYSTEMS MANAGER,
 [email protected], 561-233-0837; AS OUR RADIOS OPERATE
 ON THEIR SYSTEM FOR DETAILED RADIO FREQUENCY AND
 INSTALLATION INSTRUCTIONS.
  
 14. THE BUREAU'S APPROVAL OF THIS SUBMITTED PROJECT
 DOES NOT CONSTITUTE ITS FINAL REVIEW OR APPROVAL.
  
 15. THE BUREAU SHALL REVIEW ALL SUBMITTED BUILDING
 PLANS AT THE APPROPRIATE TIME AND IN ACCORDANCE WITH
 THE REQUIREMENTS OF ALL APPLICABLE CODES AND STANDARDS.
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]
  

Review Stop L LANDSCAPING
Rev No 2 Status F Date 12-13-2022 Cont ID  
Sent By rcaranci Date 12-13-2022 Time 16:01 Rev Time 0.00
Received By rcaranci Date 12-13-2022 Time 16:01 Sent To  
Notes
2022-12-13 16:02:33FROM: RAY CARANCI, SENIOR LANDSCAPE PLANNER
 561-822-1462
 PROJECT: 2000 S DIXIE CAREFREE Z22080023
 DECEMBER 13, 2022
 I HAVE REVIEWED THE ABOVE REFERENCED PETITION, AND
 PROVIDE THE FOLLOWING COMMENTS:
  
  
 1. ADDRESS THE FOLLOWING ON TREE DISPOSITION PLAN FOR
 THE PROJECT:
 ??? SATISFIED. IDENTIFY ALL TREES AND PALMS.
 ??? SATISFIED. REMOVE TREES AND PALMS FROM THE LIST FOR
 309 BARCELONA.
 ??? SATISFIED. CORRECT THE PLAN TO REFLECT THE TREE AND
 PALM INVENTORY FROM THE PREVIOUS PETITION FOR THE TREES
 AND PALMS THAT EXISTED AS RECORDED.
 ??? SATISFIED. PROVIDE THE FOLLOWING COLUMNS ON ONE
 DISPOSITION CHART FOR THE SUBJECT SITE: ID NUMBER,
 SPECIES, CANOPY DIAMETER, CATEGORY, CONDITION, SQUARE
 FOOTAGE MITIGATION DUE, DISPOSITION, AND PROVIDE THE
 INFORMATION FOR EACH TREE IN EACH COLUMN.
 ??? SATISFIED. FOLLOWING THE REQUIREMENTS OF THE
 CURRENT CODE SECTION 94-448, PROVIDE THE INDIVIDUAL AND
 TOTAL CANOPY MITIGATION DUE FOR ANY PROPOSED REMOVALS.
 TREES PROPOSED TO BE REMOVED WITH A CANOPY DIAMETER OF
 20 FEET OR MORE SHOULD HAVE THE MITIGATION SQUARE
 FOOTAGE CALCULATED BASED ON THE ACTUAL DIAMETER. TREES
 LESS THAN 20 FEET CANOPY DIAMETER AND PALMS SHOULD SHOW
 THE CATEGORY MITIGATION DUE.
 ??? SATISFIED. PROVIDE THE CANOPY MITIGATION DUE TOTAL
 AT THE BOTTOM OF THE CHART FOR ALL REMOVALS.
 ??? SATISFIED. PROVIDE ONE CHART FOR THE CANOPY CREDITS
 BY SPECIES AND CATEGORY PROVIDED BASED ON THE PROPOSED
 PLANT LIST FOR THE SITE AND THE ADJACENT RIGHT OF WAY.
  
 2. PARTIALLY SATISFIED. SECTION 94-448 (D)(3) REQUIRES
 NATIVE TREES AND PALMS IN GOOD CONDITION TO BE
 PRESERVED ON SITE OR RELOCATED. ANSI A 300 (PART 5)
 STANDARDS SPECIFY EXAMPLES OF SUITABILITY RATINGS OF
 GOOD, MODERATE, OR POOR FOR RELOCATION. PROVIDE AN
 ARBORISTS REPORT RATING THE CONDITION AND RELOCATION
 POTENTIAL FOR THE NATIVE TREES AND PALMS.
 ARBORIST REPORT WAS NOT SUBMITTED, APPLICANT STATED IT
 WILL BE SUBMITTED LATER.
  
 3. ONGOING. COMMENT FROM 9/30/20: SUBMIT A LANDSCAPE
 PERMIT PLAN FOR 309 BARCELONA MEETING THE MINIMUM CODE
 REQUIREMENTS FOR RESIDENTIAL LANDSCAPING AND MITIGATING
 FOR TREES REMOVED.
 A TREE ALTERATION PERMIT APPLICATION WAS SUBMITTED FOR
 THE ADDITIONAL TREES REMOVED, AND THE PERMIT WAS ISSUED
 WITH CONDITIONS. MITIGATION IS DUE FOR ALL THE TREES
 REMOVED AND MUST BE ADDRESSED WITH REPLACEMENT OF TREES
 ON SITE OR PAYMENT IN LIEU. THE MINIMUM LANDSCAPE
 REQUIREMENTS MUST BE MET ON SITE WITH A LANDSCAPE
 PERMIT PLAN TO BE SUBMITTED. NO MITIGATION HAS BEEN
 PROVIDED TO DATE FOR ANY TREES REMOVED FROM THE SITE.
  
 THIS IS THE FIRST REVIEW OF THE LANDSCAPE PLAN FOR 309
 BARCELONA. PER SECTION 94-448, ALL TREE REPLACEMENT
 MUST BE ON THE SUBJECT SITE TO BE COUNTED TOWARD
 MITIGATION DUE. THE 2 LIVE OAK TREES PROPOSED IN THE
 RIGHT OF WAY CANNOT BE COUNTED UNLESS THEY ARE WITHIN
 THE PROPERTY LINE, AS THIS PROPERTY IS SEPARATE FROM
 THE CPD.
  
 THE TREE ALTERATION PERMIT TP19-1785 THAT REPLACED
 PERMIT TP 17-1618 EXPIRED ON APRIL 30, 2020.THE
 LANDSCAPE PLAN SHEET LP-4 AND TREE DISPOSITION PLAN
 SHEET TD-2 MUST BE SUBMITTED UNDER LANDSCAPE PERMIT
 18030706 IN ORDER FOR THIS COMMENT TO BE SATISFIED.
  
 THE LANDSCAPE PLAN SHEET LP-5 NEEDS BE SUBMITTED UNDER
 PERMIT 18030706.
  
 9/7/22: OFFSITE LANDSCAPING CANNOT BE COUNTED TOWARD
 THE REQUIREMENTS ON SITE. REMOVE CHARTS AND DATA FOR
 309 BARCELONA AND SUBMIT UNDER THE LANDSCAPE PERMIT
 18030706 FOLLOWING THE MITIGATION DUE FROM TREE
 ALTERATION PERMIT TP 19-1785. LIVE OAK TREES IN THE
 RIGHT OF WAY ADJACENT TO THIS ADDRESS MAY NOT BE
 REMOVED WITHOUT SEPARATE PERMIT FROM THE CITY.
  
 4. SATISFIED. CORRECT THE DATA TABLE TO SHOW THE
 REQUIRED OPEN SPACE AREA AS 40% OF THE SITE AND
 CALCULATE THE REQUIRED TREES, FLOWERING TREES AND
 SHRUBS FROM THAT FIGURE.
  
 5. PARTIALLY SATISFIED. SHADE TREES ARE PREFERRED FOR
 STREET TREES TO MEET THE INTENT OF PROVIDING SHADE FOR
 PEDESTRIANS ON THE SIDEWALK. THIS IS MENTIONED TO
 COMPENSATE FOR THE WAIVER TO PROVIDE LESS REQUIRED
 LANDSCAPING. COCONUT PALMS ARE NOT APPROPRIATE AND
 SHOULD BE REPLACED WITH SHADE TREES.
 CLUSIA ROSEA SHAPE TENDS TO BE VERY WIDE, SO WILL BE
 DIFFICULT TO MANAGE PROVIDING CLEARANCE FOR VEHICLES
 ABOVE 13???6??? AT THE STREET EDGE. STAFF SUGGESTS A
 MORE MANAGEABLE SPECIES SUCH AS LIVE OAK OR GREEN
 BUTTONWOOD AT A LARGER SIZE THAN THE USUAL 20 FOOT
 HEIGHT REQUIREMENT TO IMPROVE THE STREETSCAPE. THE
 PARALLEL PARKING SPACES ALONG FLAMINGO SHOULD HAVE
 ADDITIONAL BULB OUT ADDED SO THERE IS NOT SUCH A LONG
 GAP IN THE STREET TREE PLACEMENT.
  
  
 6. PARTIALLY SATISFIED. SHOW STRUCTURAL SOIL OR SOIL
 CELLS BENEATH THE PAVED AREAS ADJACENT TO TREES TO
 PROVIDE ROOT AREA FOR THE TREES ALONG THE STREETS TO
 ASSURE THEY ARE SUSTAINABLE.
 PROVIDE A SEPARATE PLAN SHOWING THE LOCATIONS OF THE
 STRUCTURAL SOIL, THE NOTE PROVIDED IS NOT SPECIFIC
 ENOUGH.
  
 7. SATISFIED. PROVIDE AN OPEN SPACE DIAGRAM TO
 DEMONSTRATE THE AREAS PROVIDED AS OPEN SPACE AND
 LANDSCAPE AREAS ON SITE WITHIN THE PROPERTY LINES TO
 PROVIDE REFERENCE FOR THE WAIVER REQUESTS.
  
  
 8. PARTIALLY SATISFIED. PROVIDE MEASUREMENTS AND
 CALCULATIONS FOR THE BUFFER TREES REQUIRED FOR ALL
 BUFFER LENGTHS PER SECTION 94-443 B. AND INDICATE HOW
 THIS WILL BE AFFECTED THROUGH THE WAIVER REQUESTS.
 INDICATE THE WIDTH OF ALL LANDSCAPE BUFFERS PROVIDED ON
 THE LANDSCAPE PLAN.
 PROVIDE A LIST FOR EACH BUFFER AS TO WHAT TREES ARE
 BEING COUNTED TOWARD THE REQUIREMENTS.
  
 9. PARTIALLY SATISFIED. PROVIDE LOCATIONS OF LIGHTING
 ON THE LANDSCAPE PLAN TO AVOID CONFLICTS WITH
 LANDSCAPING.
 LIGHTING LOCATIONS SHOWN ALONG THE EAST BUFFER DISPLACE
 BUFFER TREES. ADJUST THE LOCATIONS OF THE LIGHTING TO
 MAINTAIN THE 30 FOOT REQUIRED SPACING FOR THE TREES.
 SABAL PALMS CAN BE ADJUSTED TO AVOID CONFLICT.
  
  
 10. PARTIALLY SATISFIED. SHOW LOCATIONS OF ROOT
 BARRIERS TO PROTECT INFRASTRUCTURE AND TREES FROM
 CONFLICTS. THIS INCLUDES WATER, SEWER, DRAINAGE,
 SIDEWALKS AND CURBS, AND ANY FIELD STRUCTURES THAT
 COULD BE IMPACTED BY TREE ROOTS.
 CHANGE ROOT BARRIER DETAIL TO HARD PLASTIC TYPE SIMILAR
 TO DEEPROOT AND REMOVE REFERENCE TO BIO BARRIER.
  
  
 11. PARTIALLY SATISFIED. SHOW LOCATIONS OF ALL GROUND
 MOUNTED EQUIPMENT INCLUDING FPL TRANSFORMERS, A/C
 UNITS, ETC., AND PROVIDE SCREENING FOR ALL GROUND
 MOUNTED EQUIPMENT AND UTILITIES.
 LOCATIONS TO BE PROVIDED OR AREAS INDICATED ON THE PLAN
 TO ACCOMMODATE REQUIRED EQUIPMENT. GIVEN THE REQUEST
 FOR WAIVERS FOR LANDSCAPE AREA AND JUSTIFICATION
 PROVIDED, THESE AREAS NEED TO BE PLANNED FOR, AS SPACE
 IS LIMITED AND CANNOT BE CHANGED AFTER APPROVAL OF
 WAIVERS.
 12/13/22: ALL EQUIPMENT, GREASE TRAPS, FIRE HYDRANTS,
 AND UNDERGROUND WATER, SEWER AND DRAINAGE LINES MUST BE
 SHOWN ON THE LANDSCAPE PLAN. THERE ARE MULTIPLE AREAS
 WHERE THE UTILITIES NEED TO BE ADJUSTED TO AVOID
 CONFLICT WITH THE PROPOSED TREES.
  
 12. ONGOING. THE RIGHT OF WAY ON S DIXIE HWY IS FDOT
 RIGHT OF WAY AND IS SUBJECT TO REVIEW AND PERMITTING BY
 FDOT. PROVIDE PRELIMINARY REVIEW OF ANY STREETSCAPE
 PROPOSED WITHIN THE FDOT RIGHT OF WAY.
  
 ADDITIONAL COMMENTS 12/13/22:
 13. ALL PLANTS MUST HAVE THE BOTANICAL NAME PROVIDED ON
 THE PLANT LIST.
  
 14. THE SEAGRAPE TREES IN THE LANDSCAPE BUFFER ALONG
 THE RESIDENTIAL LOTS FOR THE NORTH PARCEL MUST BE SHOWN
 INDIVIDUALLY ON THE LANDSCAPE PLAN TO SHOW THAT THE
 SPACING REQUIREMENT IS MET. THEY CANNOT BE SHOWN AS A
 HEDGE, AS HEDGES ARE LIMITED TO 10 FEET IN HEIGHT, AND
 THIS IS NOT MEETING THE BUFFER REQUIREMENTS.
  
 15. THE LANDSCAPE BUFFER AND WALL MUST BE CONTINUED
 ALONG THE PROPERTY LINE AT THE SOUTHEAST CORNER OF THE
 NORTH PARCEL.
  
  
 CONDITIONS OF APPROVAL
 1. PRIOR TO THE REMOVAL OR RELOCATION OF ANY TREES ON
 THE PROPERTY, A TREE ALTERATION PERMIT SHALL BE
 SUBMITTED, REVIEWED AND APPROVED BY THE DEVELOPMENT
 SERVICES DEPARTMENT, PLANNING DIVISION.
  
 2. THE APPLICANT, SUCCESSORS AND ASSIGNS SHALL BE
 RESPONSIBLE FOR THE PERMITTING AND INSTALLATION OF THE
 STREET TREES AND RIGHT OF WAY LANDSCAPING AND
 IRRIGATION APPROVED WITH THIS PETITION.
 3. THE APPLICANT, SUCCESSORS AND ASSIGNS SHALL BE
 RESPONSIBLE FOR THE MAINTENANCE OF THE ROAD RIGHT OF
 WAY LANDSCAPING AND IRRIGATION. THIS WILL BE THROUGH A
 SEPARATE MAINTENANCE AGREEMENT WITH THE CITY.
  

Review Stop L LANDSCAPING
Rev No 1 Status F Date 09-07-2022 Cont ID  
Sent By rcaranci Date 09-07-2022 Time 11:17 Rev Time 0.00
Received By rcaranci Date 09-07-2022 Time 11:17 Sent To  
Notes
2022-09-07 11:19:10FROM: RAY CARANCI, SENIOR LANDSCAPE PLANNER
 561-822-1462
 PROJECT: 2000 S DIXIE CAREFREE Z22080023
 SEPTEMBER 7, 2022
 I HAVE REVIEWED THE ABOVE REFERENCED PETITION, AND
 PROVIDE THE FOLLOWING COMMENTS:
  
  
 1. ADDRESS THE FOLLOWING ON TREE DISPOSITION PLAN FOR
 THE PROJECT:
 ? IDENTIFY ALL TREES AND PALMS.
 ? REMOVE TREES AND PALMS FROM THE LIST FOR 309
 BARCELONA.
 ? CORRECT THE PLAN TO REFLECT THE TREE AND PALM
 INVENTORY FROM THE PREVIOUS PETITION FOR THE TREES AND
 PALMS THAT EXISTED AS RECORDED.
 ? PROVIDE THE FOLLOWING COLUMNS ON ONE DISPOSITION
 CHART FOR THE SUBJECT SITE: ID NUMBER, SPECIES, CANOPY
 DIAMETER, CATEGORY, CONDITION, SQUARE FOOTAGE
 MITIGATION DUE, DISPOSITION, AND PROVIDE THE
 INFORMATION FOR EACH TREE IN EACH COLUMN.
 ? FOLLOWING THE REQUIREMENTS OF THE CURRENT CODE
 SECTION 94-448, PROVIDE THE INDIVIDUAL AND TOTAL CANOPY
 MITIGATION DUE FOR ANY PROPOSED REMOVALS. TREES
 PROPOSED TO BE REMOVED WITH A CANOPY DIAMETER OF 20
 FEET OR MORE SHOULD HAVE THE MITIGATION SQUARE FOOTAGE
 CALCULATED BASED ON THE ACTUAL DIAMETER. TREES LESS
 THAN 20 FEET CANOPY DIAMETER AND PALMS SHOULD SHOW THE
 CATEGORY MITIGATION DUE.
 ? PROVIDE THE CANOPY MITIGATION DUE TOTAL AT THE BOTTOM
 OF THE CHART FOR ALL REMOVALS.
 ? PROVIDE ONE CHART FOR THE CANOPY CREDITS BY SPECIES
 AND CATEGORY PROVIDED BASED ON THE PROPOSED PLANT LIST
 FOR THE SITE AND THE ADJACENT RIGHT OF WAY.
  
 2. SECTION 94-448 (D)(3) REQUIRES NATIVE TREES AND
 PALMS IN GOOD CONDITION TO BE PRESERVED ON SITE OR
 RELOCATED. ANSI A 300 (PART 5) STANDARDS SPECIFY
 EXAMPLES OF SUITABILITY RATINGS OF GOOD, MODERATE, OR
 POOR FOR RELOCATION. PROVIDE AN ARBORISTS REPORT RATING
 THE CONDITION AND RELOCATION POTENTIAL FOR THE NATIVE
 TREES AND PALMS.
  
 3. COMMENT FROM 9/30/20: SUBMIT A LANDSCAPE PERMIT PLAN
 FOR 309 BARCELONA MEETING THE MINIMUM CODE REQUIREMENTS
 FOR RESIDENTIAL LANDSCAPING AND MITIGATING FOR TREES
 REMOVED.
 A TREE ALTERATION PERMIT APPLICATION WAS SUBMITTED FOR
 THE ADDITIONAL TREES REMOVED, AND THE PERMIT WAS ISSUED
 WITH CONDITIONS. MITIGATION IS DUE FOR ALL THE TREES
 REMOVED AND MUST BE ADDRESSED WITH REPLACEMENT OF TREES
 ON SITE OR PAYMENT IN LIEU. THE MINIMUM LANDSCAPE
 REQUIREMENTS MUST BE MET ON SITE WITH A LANDSCAPE
 PERMIT PLAN TO BE SUBMITTED. NO MITIGATION HAS BEEN
 PROVIDED TO DATE FOR ANY TREES REMOVED FROM THE SITE.
  
 THIS IS THE FIRST REVIEW OF THE LANDSCAPE PLAN FOR 309
 BARCELONA. PER SECTION 94-448, ALL TREE REPLACEMENT
 MUST BE ON THE SUBJECT SITE TO BE COUNTED TOWARD
 MITIGATION DUE. THE 2 LIVE OAK TREES PROPOSED IN THE
 RIGHT OF WAY CANNOT BE COUNTED UNLESS THEY ARE WITHIN
 THE PROPERTY LINE, AS THIS PROPERTY IS SEPARATE FROM
 THE CPD.
  
 THE TREE ALTERATION PERMIT TP19-1785 THAT REPLACED
 PERMIT TP 17-1618 EXPIRED ON APRIL 30, 2020.THE
 LANDSCAPE PLAN SHEET LP-4 AND TREE DISPOSITION PLAN
 SHEET TD-2 MUST BE SUBMITTED UNDER LANDSCAPE PERMIT
 18030706 IN ORDER FOR THIS COMMENT TO BE SATISFIED.
 12. THE RIGHT OF WAY ON S DIXIE HWY IS FDOT RIGHT OF
 WAY AND IS SUBJECT TO REVIEW AND PERMITTING BY FDOT.
 PROVIDE PRELIMINARY REVIEW OF ANY STREETSCAPE PROPOSED
 WITHIN THE FDOT RIGHT OF WAY.
 THE LANDSCAPE PLAN SHEET LP-5 NEEDS BE SUBMITTED UNDER
 PERMIT 18030706.
  
 9/7/22: OFFSITE LANDSCAPING CANNOT BE COUNTED TOWARD
 THE REQUIREMENTS ON SITE. REMOVE CHARTS AND DATA FOR
 309 BARCELONA AND SUBMIT UNDER THE LANDSCAPE PERMIT
 18030706 FOLLOWING THE MITIGATION DUE FROM TREE
 ALTERATION PERMIT TP 19-1785. LIVE OAK TREES IN THE
 RIGHT OF WAY ADJACENT TO THIS ADDRESS MAY NOT BE
 REMOVED WITHOUT SEPARATE PERMIT FROM THE CITY.
  
 4. CORRECT THE DATA TABLE TO SHOW THE REQUIRED OPEN
 SPACE AREA AS 40% OF THE SITE AND CALCULATE THE
 REQUIRED TREES, FLOWERING TREES AND SHRUBS FROM THAT
 FIGURE.
  
 5. SHADE TREES ARE PREFERRED FOR STREET TREES TO MEET
 THE INTENT OF PROVIDING SHADE FOR PEDESTRIANS ON THE
 SIDEWALK. THIS IS MENTIONED TO COMPENSATE FOR THE
 WAIVER TO PROVIDE LESS REQUIRED LANDSCAPING. COCONUT
 PALMS ARE NOT APPROPRIATE AND SHOULD BE REPLACED WITH
 SHADE TREES.
  
 6. SHOW STRUCTURAL SOIL OR SOIL CELLS BENEATH THE PAVED
 AREAS ADJACENT TO TREES TO PROVIDE ROOT AREA FOR THE
 TREES ALONG THE STREETS TO ASSURE THEY ARE SUSTAINABLE.
  
 7. PROVIDE AN OPEN SPACE DIAGRAM TO DEMONSTRATE THE
 AREAS PROVIDED AS OPEN SPACE AND LANDSCAPE AREAS ON
 SITE WITHIN THE PROPERTY LINES TO PROVIDE REFERENCE FOR
 THE WAIVER REQUESTS.
  
  
 8. PROVIDE MEASUREMENTS AND CALCULATIONS FOR THE BUFFER
 TREES REQUIRED FOR ALL BUFFER LENGTHS PER SECTION
 94-443 B. AND INDICATE HOW THIS WILL BE AFFECTED
 THROUGH THE WAIVER REQUESTS. INDICATE THE WIDTH OF ALL
 LANDSCAPE BUFFERS PROVIDED ON THE LANDSCAPE PLAN.
  
  
  
  
 9. PROVIDE LOCATIONS OF LIGHTING ON THE LANDSCAPE PLAN
 TO AVOID CONFLICTS WITH LANDSCAPING.
  
 10. SHOW LOCATIONS OF ROOT BARRIERS TO PROTECT
 INFRASTRUCTURE AND TREES FROM CONFLICTS. THIS INCLUDES
 WATER, SEWER, DRAINAGE, SIDEWALKS AND CURBS, AND ANY
 FIELD STRUCTURES THAT COULD BE IMPACTED BY TREE ROOTS.
  
 11. SHOW LOCATIONS OF ALL GROUND MOUNTED EQUIPMENT
 INCLUDING FPL TRANSFORMERS, A/C UNITS, ETC., AND
 PROVIDE SCREENING FOR ALL GROUND MOUNTED EQUIPMENT AND
 UTILITIES.
 LOCATIONS TO BE PROVIDED OR AREAS INDICATED ON THE PLAN
 TO ACCOMMODATE REQUIRED EQUIPMENT. GIVEN THE REQUEST
 FOR WAIVERS FOR LANDSCAPE AREA AND JUSTIFICATION
 PROVIDED, THESE AREAS NEED TO BE PLANNED FOR, AS SPACE
 IS LIMITED AND CANNOT BE CHANGED AFTER APPROVAL OF
 WAIVERS.
  
 12. THE RIGHT OF WAY ON S DIXIE HWY IS FDOT RIGHT OF
 WAY AND IS SUBJECT TO REVIEW AND PERMITTING BY FDOT.
 PROVIDE PRELIMINARY REVIEW OF ANY STREETSCAPE PROPOSED
 WITHIN THE FDOT RIGHT OF WAY.
  
 CONDITIONS OF APPROVAL
 1. PRIOR TO THE REMOVAL OR RELOCATION OF ANY TREES ON
 THE PROPERTY, A TREE ALTERATION PERMIT SHALL BE
 SUBMITTED, REVIEWED AND APPROVED BY THE DEVELOPMENT
 SERVICES DEPARTMENT, PLANNING DIVISION.
  
 2. THE APPLICANT, SUCCESSORS AND ASSIGNS SHALL BE
 RESPONSIBLE FOR THE PERMITTING AND INSTALLATION OF THE
 STREET TREES AND RIGHT OF WAY LANDSCAPING AND
 IRRIGATION APPROVED WITH THIS PETITION.
 3. THE APPLICANT, SUCCESSORS AND ASSIGNS SHALL BE
 RESPONSIBLE FOR THE MAINTENANCE OF THE ROAD RIGHT OF
 WAY LANDSCAPING AND IRRIGATION. THIS WILL BE THROUGH A
 SEPARATE MAINTENANCE AGREEMENT WITH THE CITY.
  

Review Stop PARK PARKING
Rev No 1 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time  
Received By   Date   Time   Sent To  
Notes
***NONE***

Review Stop POLICE POLICE
Rev No 1 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time  
Received By   Date   Time   Sent To  
Notes
***NONE***

Review Stop PU PUBLIC UTILITIES
Rev No 2 Status F Date 12-12-2022 Cont ID  
Sent By mtechnow Date 12-12-2022 Time 10:45 Rev Time 0.00
Received By mtechnow Date 12-12-2022 Time 10:43 Sent To  
Notes
2022-12-12 10:45:14PREVIOUS COMMENTS NOT SATISFIED. CANNOT TAP THE 20"
 TRANSMISSION WATER MAIN PER DISCUSSION WITH CONSULTANT
 AND PREVIOUS SUBMITTAL COMMENTS.

Review Stop PU PUBLIC UTILITIES
Rev No 1 Status F Date 09-08-2022 Cont ID  
Sent By mtechnow Date 09-08-2022 Time 12:00 Rev Time 0.00
Received By mtechnow Date 09-08-2022 Time 11:53 Sent To  
Notes
2022-09-08 12:00:07-CANNOT TAP THE 20" TRANSMISSION WM ON BARCELONA RD.
 PLEASE REVISE PROPOSED SERVICE CONNECTIONS.
 -UTILITIES IS REVIEWING THE PROPOSED REMOVAL OF THE 6"
 WM ON THE SOUTH SIDE OF THE PROJECT FOR POTENTIAL WATER
 QUALITY ISSUES.

Review Stop PU-CS PUBLIC UTILITIES CUSTOMER SRVC
Rev No 2 Status F Date 12-07-2022 Cont ID  
Sent By mhurley Date 12-07-2022 Time 08:47 Rev Time 0.00
Received By mhurley Date   Time   Sent To  
Notes
2022-12-07 08:47:07PLEASE PROVIDE WRITTEN RESPONSES TO THE FOLLOWING:
 -COULD NOT LOCATE WATER AND SEWER DEMAND CALCULATIONS
 ON UTILITY PLANS AS INDICATED IN RESPONSE LETTER.
 PLEASE ADD.
 -RESPONSE LETTER REFERRED TO SHEET C502, BUT COULD NOT
 FIND THAT SHEET IN CIVIL PLAN SET.
 -SHEET C503 SHOWS SYMBOLS THAT LOOK LIKE STREET SIGNS
 CLOSE TO WATER SERVICES. PLEASE ADD THOSE SYMBOLS TO
 THE LEGEND AND ENSURE AT LEAST SEVERAL FEET OF
 HORIZONTAL CLEARANCE DISTANCE BETWEEN POLES AND WATER
 SERVICES.
 -ON SHEET C200 CLEARLY LABEL WHAT IS HAPPENING TO
 EXISTING 7 FOOT UTILITY EASEMENT. IF REMAINING, SHOW
 CLEARLY ON UTILITY PLANS.
 -APPLICANT MUST PAY ALL UTILITY BILLING FEES RELATED TO
 PROJECT.
 -PROPOSED GREASE TRAP LOCATION ON SHEET C500 SEEMS
 UNUSUAL BECAUSE THERE IS NOT A NEARBY SANITARY SEWER
 MAIN OR LATERAL. NOT SURE IF PLUMBING PIPE IS EXISTING
 BUILDING AND THEN RETURNING OR THERE WILL BE LONG PIPE
 DISTANCE TO LATERAL.
 -PROPOSED 20 INCH WATER MAIN TAP MAY BE REVIEWED
 FURTHER AT ENGINEERING DEVELOPMENT SUBMITTAL.
 -THERE APPEARS TO BE LOCATION CONFLICTS WITH
 LANDSCAPING AND UTILITIES. PLEASE SHOW UTILITIES ON
 LANDSCAPING PLANS AND ENSURE THEY ARE APPROPRIATELY
 DISTANCED FROM EACH OTHER.
 -ADD STANDARD DETAIL P8 TO PLAN SET.
 -SEE NOTE 3 ON STANDARD DETAIL P8 AND REVISE FIRE
 HYDRANT LOCATIONS.
 -ENSURE LIGHTING ON PH1 AND WATER UTILITIES ARE
 APPROPRIATELY DISTANCED FROM EACH OTHER.
 -VERIFY NO AUXILIARY WATER SOURCES SUCH AS WELLS WILL
 BE CONNECTED TO PRIVATE FIRE SYSTEM.
 -T2.0 SHOWS DO NOT ENTER SIGNS ON SOUTHERN DRIVEWAY OF
 BARCELONA, BUT T2.1 SHOWS MOVING TRUCK ENTERING THE
 DRIVEWAY.
 RESPECTFULLY,
 MARK HURLEY [email protected]

Review Stop PU-CS PUBLIC UTILITIES CUSTOMER SRVC
Rev No 1 Status F Date 09-04-2022 Cont ID  
Sent By mhurley Date 09-04-2022 Time 08:41 Rev Time 0.00
Received By mhurley Date   Time   Sent To  
Notes
2022-09-04 08:41:43PLEASE PROVIDE WRITTEN RESPONSES TO THE FOLLOWING:
 -ADD COVER SHEET TO CIVIL PLANS WITH MAP OF LOCATION.
 -ADD WATER AND SEWER DEMAND CALCULATIONS TO UTILITY
 PLAN SHEETS.
 -FOR CIVIL PLAN SET, ADD STANDARD DETAILS SHEET WITH
 REFERENCED STANDARD DETAILS.
 -DIXIE HWY IS FDOT ROW.
 -ADD WORDING ABOVE-GROUND TO THE LABELS OF THE PROPOSED
 6 INCH AND 4 INCH METERS.
 -SURVEY IS NOT SIGNED, SEALED, AND DATED.
 -SURVEY SHOWS EXISTING UTILITY EASEMENTS RUNNING
 THROUGH PROPERTY, BUT THEY ARE NOT SHOWN AND LABELED ON
 CIVIL PLANS.
 -STRUCTURES MAY NOT BE BUILT ON UTILITY EASEMENTS
 WITHOUT APPROVAL OF CITY.
 -CIVIL PLANS SHOW CONFLICTS WITH UTILITY POLES AND GUY
 WIRES. ADD DEMO PLAN SHEET IF THOSE ARE BEING REMOVED,
 RELOCATED, OR UNDERGROUNDED.
 -SHOW AND LABEL ANY PROPOSED TRANSFORMER PADS.
 -JUSTIFICATION DOCUMENT SAID THERE ARE PROPOSED
 RESTAURANTS, BUT DID NOT SEE ANY GREASE TRAPS. SHOW AND
 LABEL ANY GREASE TRAPS WHICH ARE PROPOSED OUTSIDE OF
 BUILDING.
 -PROPOSED TAPS ON 20 INCH WATER MAIN WOULD REQUIRE
 APPROVAL OF MICHAEL TECHNOW.
 -SHEET C501. UTILITY OR LIGHT POLES APPEAR TO BE CLOSE
 TO WATER UTILITIES. PROVIDE AT LEAST SEVERAL FEET OF
 HORIZONTAL CLEARANCE DISTANCE BETWEEN THEM.
 -ADD A LANDSCAPING SHEET SHOWING ALL TREES, BUSHES, AND
 UTILITIES. ENSURE THERE IS ADEQUATE CLEARANCE DISTANCE
 BETWEEN PLANTS AND UTILITIES.
 -ON LANDSCAPING, CIVIL, AND ARCHITECTURAL PLANS, ADD
 LEGEND IDENTIFYING SYMBOLS USED.
 -THE SOUTHERN BUILDING SHOWS SOMETHING THAT LOOKS LIKE
 OUTDOOR TABLES ADJACENT THE NORTH SIDE. CIVIL PLANS
 SHOW ABOVE-GROUND WATER METER, TRAFFIC SIGN, AND LIGHT
 POLE THERE ALSO. WILL THERE BE ADEQUATE WIDTH FOR
 PEDESTRIAN MOVEMENT THERE?
 -BYPASS OF 6 INCH WATER METER FOR SOUTHERN BUILDING
 CANNOT BE IN OR UNDER CURB.
 -WHAT IS THE PLAN FOR THE AREA BETWEEN THE BULBOUTS?
 ARE THEY PARKING SPOTS? SHOW OR DETAIL MORE CLEARLY ON
 PLANS.
 -SHOW TRAFFIC SIGN NEAR NORTHEAST CORNER OF SOUTHERN
 BUILDING ON UTILITY PLANS. CALLOUT MINIMUM 18 INCH
 CLEARANCE DISTANCE BETWEEN SIGN AND BACKFLOW ASSEMBLY.
 ALSO WILL TRAFFIC SIGN CONFLICT WITH TRAFFIC GATE
 OPENING?
 -IS THE DRIVE PATH ON THE EAST SIDE OF SOUTHERN
 BUILDING ONE WAY? SHOW OR DETAIL MORE CLEARLY ON PLANS.
 ALSO THE NORTHEAST CURB ISLAND DOES NOT ALIGN WITH IT.
 -PAVEMENT RESTORATION LIMITS FROM UTILITY WORK ARE
 LIKELY MUCH LARGER THAN SHOWN ON CIVIL PLANS.
 -LIGHT POLE SHOWING IN DRIVEWAY ON SHEET C501.
 -BACKFLOW ASSEMBLIES FOR NORTH BUILDING MAY BE
 CONFLICTING WITH A WALL. CALLOUT THE OBJECT AND RESOLVE
 ANY LOCATION CONFLICTS.
 -ATTEMPT TO REPOSITION THE WATER SERVICES FOR THE NORTH
 BUILDING SUCH THAT THE FIRE SERVICE DOES NOT RUN
 UNDERNEATH TWO OTHER LARGE WATER SERVICES.
 -WATER METER BOXES MAY NOT ENCROACH INTO CURBS. WATER
 VALVE BOXES SHOULD ALSO NOT BE LOCATED IN CURBS.
 -C500. PROPOSED BACKFLOW ASSEMBLIES CONFLICTING WITH
 EXISTING STORM MANHOLE AND CLEANOUT AS SHOWN ON SURVEY.
 -PLANS DO NOT SHOW ANY OF THE EXISTING NORTH SOUTH OR
 EAST WEST CROSSWALKS.
 -APPLICANT MAY BE REQUIRED TO REROUTE OR BUILD NEW
 WATER MAIN FOR THE ONE THAT IS PROPOSED FOR REMOVAL.
 -ADD ADJACENT PROPERTY ADDRESSES ON CIVIL PLANS.
 -SHOW AND LABEL FDC IF THEY ARE NEEDED OR REQUIRED.
 ENSURE THEY ARE ACCEPTABLE DISTANCE FROM FIRE HYDRANT.
 RESPECTFULLY,
 MARK HURLEY [email protected]

Review Stop PW PUBLIC WORKS
Rev No 2 Status F Date 11-30-2022 Cont ID  
Sent By   Date 11-30-2022 Time   Rev Time 0.00
Received By   Date 11-30-2022 Time   Sent To  
Notes
2022-11-30 15:24:10PLEASE PROVIDE THE FOLLOWINGS:
 1- DUMPSTER ENCLOSURE DETAIL. DETAILS FOR SANITATION
 SERVICE (I.E. SOLID WASTE CONTAINER(S) TYPE, COLLECTION
 LOCATION, ETC.). FOR A FREESTANDING SITE DUMPSTER
 ENCLOSURE, THE ENCLOSURE SHALL COMPLY WITH THE LATEST
 REVISION OF CITY OF WEST PALM BEACH GENERAL
 CONSTRUCTION-GARBAGE ENCLOSURE STANDARD, GC-7. (LINK TO
 THE LATEST REVISION OF THE GC-7 DOCUMENT: HTTPS://WWW.W
 PB.ORG/HOME/SHOWPUBLISHEDDOCUMENT/3690/6376290604221000
 00)
 2- DESIGNATED STAGING AREA FOR THE BULK WASTE.
 3- AUTOTURN EXHIBIT WITH DYNAMIC ENVELOPE AND THE
 VEHICLE???S WHEEL PATH IDENTIFIED WITH DIFFERENT COLORS
 FOR THE SANITATION SERVICE, FRONT LOADER TRUCK WITH THE
 FOLLOWING SPECS:
 - DUAL AXLES
 - TRUCK LENGTH: 35 FT
 - TRUCK WIDTH: 11 FT
 - TURNING RADIUS:
 - SAE TURNING RADIUS: 32.5 FT
 - CURB-TO-CURB DIAMETER: 74 FT
 - WALL-TO-WALL DIAMETER: 86.3 FT
  
  
 MATT HEJAZI
 DEPT OF PUBLIC WORKS
 [email protected]
 561-822-2045
  
  

Review Stop PW PUBLIC WORKS
Rev No 1 Status F Date 08-26-2022 Cont ID  
Sent By   Date 08-26-2022 Time   Rev Time  
Received By   Date 08-26-2022 Time   Sent To  
Notes
2022-08-26 15:20:58 
 PLEASE PROVIDE THE FOLLOWINGS:
 1- LOS (LEVEL OF SERVICE ANALYSIS) TO REFLECT THE SOLID
 WASTE VOLUME PRODUCED ALONG WITH THE SIZE, TYPE AND
 QUANTITY OF THE CONTAINER (I.E. DUMPSTER/COMPACTOR)
 THAT WILL BE UTILIZED FOR THE SANITATION SERVICE.
 2- DETAILS FOR SANITATION SERVICE (I.E. SOLID WASTE
 CONTAINER(S) TYPE, COLLECTION LOCATION, ETC.). FOR A
 FREESTANDING SITE DUMPSTER ENCLOSURE, THE ENCLOSURE
 SHALL COMPLY WITH THE LATEST REVISION OF CITY OF WEST
 PALM BEACH GENERAL CONSTRUCTION-GARBAGE ENCLOSURE
 STANDARD, GC-7. (LINK TO THE LATEST REVISION OF THE
 GC-7 DOCUMENT: HTTPS://WWW.WPB.ORG/HOME/SHOWPUBLISHEDDO
 CUMENT/3690/637629060422100000)
 3- AUTOTURN EXHIBIT (DYNAMIC ENVELOPE AND THE VEHICLE?S
 WHEEL PATH) FOR THE SANITATION SERVICE, FRONT LOADER
 TRUCK WITH THE FOLLOWING SPECS:
 - DUAL AXLES
 - TRUCK LENGTH: 35 FT
 - TRUCK WIDTH: 11 FT
 - TURNING RADIUS:
 - SAE TURNING RADIUS: 32.5 FT
 - CURB-TO-CURB DIAMETER: 74 FT
 - WALL-TO-WALL DIAMETER: 86.3 FT
 4- DESIGNATED LOCATION FOR THE BULK ITEM PICK UP AND
 RECYCLING CONTAINERS
 5- OWNERS AND/OR OCCUPANTS OF PROPERTY THAT REQUIRE
 GREASE HAULING SERVICES SHALL ENSURE THAT THEIR GREASE
 TANKS OR CONTAINERS REMAIN CLEAN, AND ARE ENCLOSED AND
 NOT IN PUBLIC VIEW.
 6- IN CASE OF PROPOSING ADDITION OF ANY NEW CAN(S) IN
 THE CITY`S RIGHT-OF-WAY , THE LOCATION AND QUANTITY OF
 THE CAN(S) SHALL BE REVIEWED AND APPROVED BY PUBLIC
 WORKS DEPARTMENT AND THE CAN(S) SHALL BE TYPE, SIZE AND
 COLOR APPROVED BY PUBLIC WORKS DEPARTMENT. THE BUILDING
 MAINTENANCE IS RESPONSIBLE TO MAINTAIN AND SERVICE THE
 CAN(S).
 7- ALL THE PARKING STALL PAINTING SHALL COMPLY WITH THE
 CITY`S MUNICIPAL CODE SECTION 94-485 AND FLORIDA
 STATUES [553.5041 F.S.].
 8- SIGNAGE PLAN. ALL STRIPING AND SIGNAGE SHALL COMPLY
 WITH THE LATEST CITY OF WEST PALM BEACH STANDARD
 DETAILS AND MEET THE M.U.T.C.D. LATEST EDITION.
 9- ALL PAVEMENT MARKING , SIGNING AND SIDEWALK DAMAGED
 DURING CONSTRUCTION SHALL BE RESTORED.
  
  
 MATT HEJAZI
 DEPT. OF PUBLIC WORKS
 [email protected]
 561-822-2045
  

Review Stop STORM STORMWATER
Rev No 2 Status F Date 01-09-2023 Cont ID  
Sent By tward Date 01-09-2023 Time 13:26 Rev Time 0.00
Received By tward Date 01-09-2023 Time 13:28 Sent To  
Notes
2023-01-09 13:28:10THE FOLLOWING COMMENTS ARE FROM THE REVIEW OF THE
 11-22-2022 SUBMITTAL:
  
 1. [PARTIALLY SATISFIED] THE CITY???S OFFICIAL VERTICAL
 DATUM IS NGVD1929. THE CITY HAS ALLOWED THE USE OF
 NAVD1988 AS LONG AS THE CONVERSION EQUATION TO NGVD1929
 AT THE PROJECT LOCATION IS PROVIDED. PROVIDE THE
 VERTICAL REFERENCE AND DATUM CONVERSION TO NGVD1929 ON
 EACH ENGINEERING PLAN SHEET WITH ELEVATION INFORMATION.
 ADDITIONAL COMMENT: ADD REQUESTED INFORMATION TO SHEETS
 C-200, C-201, C-600, C-601, T-1.0, T-1.1, T-2.0, T-2.1,
  
 2. S. DIXIE HWY IS MAINTAINED BY FDOT. FDOT TO APPROVE
 ALL PROPOSED IMPROVEMENTS WITHIN THE R/W.
  
 3. [SATISFIED ??? SEE ADDITIONAL COMMENTS BELOW]
 PROVIDE CROSS SECTIONS FROM CENTERLINE OF RIGHTS OF WAY
 AND THE EAST PROPERTY LINES TO THE BUILDING FACES. SHOW
 AND LABEL SURFACE FEATURES, GRADE BREAKS, GENERAL
 SURFACE SLOPES, FINISHED FLOOR ELEVATION, RIGHT OF WAY
 LINES WITH THE STREET IDENTIFIED, DIMENSIONS FROM RIGHT
 OF WAY TO SURFACE FEATURES. IT APPEARS FFE ARE 1 FT OR
 HIGHER THAN R/W GRADES.
  
 4. [NOT SATISFIED] PROVIDE CROSS SECTIONS FOR ALL
 DRIVEWAYS FROM THE CENTERLINE OF THE ROAD TO 5 FEET
 PAST THE HIGH POINT OF THE DRIVEWAY. SHOW AND LABEL THE
 RIGHT OF WAY LINE, R/W STREET NAME, SURFACE FEATURES,
 SURFACE SLOPES, GRADE BREAKS, ETC.
  
 5. [SATISFIED] SUGGEST PUTTING TRENCH DRAINS AT THE
 BACK OF SIDEWALKS (AND OUTSIDE THE R/W) TO REDUCE
 TRIPPING HAZARD.
  
 6. [NOT SATISFIED] PROVIDE SURFACE FLOW ARROWS ON THE
 GRADING AND DRAINAGE PLANS.
  
 7. [SATISFIED] LABEL EXISTING UTILITIES (SIZE,
 MATERIAL).
  
 8. [NOT SATISFIED ??? HATCHING NOT FOUND ON SHEETS
 T-1.1 (OR T-1.0)] SHOW MILL AND RESURFACING LIMITS THAT
 MEET CITY DETAILS.
  
 9. [SATISFIED] PROVIDE STRIPING PLAN FOR DISTURBED
 PAVEMENT AREAS.
  
 NEW COMMENTS (11/22-2022 SUBMITTAL)
  
 10. TWO SHEETS NUMBERED T-2.0 AND TWO SHEETS NUMBERED
 T-2.1.
  
 11. PROVIDE SIGN LEGEND ON SHEETS T-1.0 AND T-1.1.
  
 12. DEMOLITION PLAN SHEET C-200 CALLS OUT THE REMOVAL
 OF THE EXISTING FDOT DRAINAGE STRUCTURE ON S. DIXIE HWY
 SOUTH OF FLAMINGO DRIVE. THE CONCEPTUAL GRADING AND
 DRAINAGE PLAN DOES NOT SHOW THE STRUCTURE BEING
 REPLACED. WILL IT BE CONVERTED TO A MANHOLE TOP? HOW
 WILL SURFACE RUNOFF ON S. DIXIE HWY ENTER THE DRAINAGE
 SYSTEM?
  
 13. DEMOLITION PLAN SHEET C-201 CALLS OUT THE REMOVAL
 OF THE EXISTING FDOT DRAINAGE STRUCTURE ON S. DIXIE HWY
 SOUTH OF BARCELONA ROAD. THE CONCEPTUAL GRADING AND
 DRAINAGE PLAN DOES NOT SHOW THE STRUCTURE BEING
 REPLACED. WILL IT BE CONVERTED TO A MANHOLE TOP? HOW
 WILL SURFACE RUNOFF ON S. DIXIE HWY ENTER THE DRAINAGE
 SYSTEM?
  
 14. PROVIDE PROPOSED EDGE OF PAVEMENT ELEVATIONS FOR
 THE CURB AND GUTTER AND VALLEY GUTTER ON S. DIXIE
 HIGHWAY. FDOT MAY REQUIRE SPREAD CALCULATIONS TO SEE
 HOW MUCH OF THE TRAVEL MAY BE AFFECTED BY THE
 RELOCATION OF THE CURB AND GUTTER AND ELIMINATION OF
 DRAINAGE STRUCTURES.
  
 15. PROVIDE PROPOSED EDGE OF PAVEMENT ELEVATIONS FOR
 THE CURB AND GUTTER AND VALLEY GUTTER ON FLAMINGO
 DRIVE.
  
 16. SOUTH CURB LINE ON FLAMINGO DRIVE IS BEING MOVED
 TOWARD THE CENTERLINE BY ~5 FEET. HOW WILL THE PROPOSED
 CURB CONNECT INTO THE EXISTING CURB LINE EAST OF THE
 PROJECT SITE?
  
 17 LABEL THE STREET NAMES ON THE SECTIONS ON SHEETS
 C-400 AND C-401.
  
 18. SECTION A-A???
 A. INDICATE WHERE THE TRAVEL LANE CONSTRUCTION WILL
 MATCH EXISTING ELEVATION.
 B. CONFIRM NONE OF THE SIDEWALK CROSS SLOPE WILL EXCEED
 2 PERCENT.
  
 19. SECTION B-B???
 A. REVIEW THE DIMENSIONS FOR THE PROPOSED TRAVEL LANE
 (13 FEET FROM ROAD CENTERLINE TO EDGE OF PAVEMENT
 ADJACENT TO THE VALLEY GUTTER) AND PROPOSED PARKING (11
 FEET FROM FACE OF D???CURB TO EDGE OF TRAVEL LANE ???
 INCLUDES THE VALLEY GUTTER). IN PLAN VIEW, THE PROPOSED
 EDGE OF PAVEMENT IS 13.5 FEET FROM THE ROAD CENTERLINE
 AND 10.5 FEET FROM THE FACE OF PROPOSED D-CURB.
 B. CONFIRM NONE OF THE SIDEWALK CROSS SLOPE WILL EXCEED
 2 PERCENT.
 C. THE EXISTING CROWN OF ROAD APPEARS TO BE 5 FEET
 SOUTH OF THE ROAD CENTERLINE.
  
 20. SECTION C-C???
  A. PLAN VIEW APPEARS TO SHOW A CURB ALONG THE WEST
 SIDE OF THE TRAVEL LANE.
  
 21. SECTION E-E???
 A. INDICATE WHERE THE TRAVEL LANE CONSTRUCTION WILL
 MATCH EXISTING ELEVATION.
 B. THE EXISTING ROAD CROWN APPEARS TO BE APPROX.. 4
 FEET WEST OF THE ROAD CENTERLINE.
  
 22. SECTION F-F???
 A. INDICATE WHERE THE TRAVEL LANE CONSTRUCTION WILL
 MATCH EXISTING ELEVATION.
  
 23. FOR ENGINEERING PERMIT, PROVIDE PLAN AND PROFILE
 SHEET OF THE RECONSTRUCTION OF BARCELONA ROAD FROM THE
 CENTERLINE OF S. DIXIE HWY TO APPROXIMATELY 230 FEET
 EAST OF THE S. DIXIE HWY CENTELINE. SHOW PROFILES OF
 ALL UTILITIES WITHIN THE R/W AND CROSS SECTIONS OF THE
 UTILITIES CROSSING THESE UTILITIES.
  
 TRACY WARD, PE
 SENIOR STORMWATER ENGINEER
 ENGINEERING SERVICES DEPARTMENT
 561-494-1120 (O)
 561-351-0510 (M)
 [email protected]
  

Review Stop STORM STORMWATER
Rev No 1 Status F Date 09-08-2022 Cont ID  
Sent By tward Date 09-08-2022 Time 13:03 Rev Time 0.00
Received By tward Date 09-08-2022 Time 13:04 Sent To  
Notes
2022-09-08 13:04:51THIS IS A CONCEPTUAL LEVEL REVIEW. CONSTRUCTION LEVEL
 DETAILS, DESIGN CALCULATIONS AND THE POLLUTION
 PREVENTION PLAN WILL BE REVIEWED AS PART OF THE
 ENGINEERING DEVELOPMENT APPROVAL AND BUILDING PERMIT
 APPLICATION PROCESSES.
  
 THE FOLLOWING COMMENTS MUST BE ADDRESSED PRIOR TO SITE
 PLAN APPROVAL:
  
  
 1. THE CITY?S OFFICIAL VERTICAL DATUM IS NGVD1929. THE
 CITY HAS ALLOWED THE USE OF NAVD1988 AS LONG AS THE
 CONVERSION EQUATION TO NGVD1929 AT THE PROJECT LOCATION
 IS PROVIDED. PROVIDE THE VERTICAL REFERENCE AND DATUM
 CONVERSION TO NGVD1929 ON EACH ENGINEERING PLAN SHEET
 WITH ELEVATION INFORMATION.
  
 2. S. DIXIE HWY IS MAINTAINED BY FDOT. FDOT TO APPROVE
 ALL PROPOSED IMPROVEMENTS WITHIN THE R/W.
  
 3. PROVIDE CROSS SECTIONS FROM CENTERLINE OF RIGHTS OF
 WAY AND THE EAST PROPERTY LINES TO THE BUILDING FACES.
 SHOW AND LABEL SURFACE FEATURES, GRADE BREAKS, GENERAL
 SURFACE SLOPES, FINISHED FLOOR ELEVATION, RIGHT OF WAY
 LINES WITH THE STREET IDENTIFIED, DIMENSIONS FROM RIGHT
 OF WAY TO SURFACE FEATURES. IT APPEARS FFE ARE 1 FT OR
 HIGHER THAN R/W GRADES.
  
 4. PROVIDE CROSS SECTIONS FOR ALL DRIVEWAYS FROM THE
 CENTERLINE OF THE ROAD TO 5 FEET PAST THE HIGH POINT OF
 THE DRIVEWAY. SHOW AND LABEL THE RIGHT OF WAY LINE, R/W
 STREET NAME, SURFACE FEATURES, SURFACE SLOPES, GRADE
 BREAKS, ETC.
  
 5. SUGGEST PUTTING TRENCH DRAINS AT THE BACK OF
 SIDEWALKS (AND OUTSIDE THE R/W) TO REDUCE TRIPPING
 HAZARD.
  
 6. PROVIDE SURFACE FLOW ARROWS ON THE GRADING AND
 DRAINAGE PLANS.
  
 7. LABEL EXISTING UTILITIES (SIZE, MATERIAL).
  
 8. SHOW MILL AND RESURFACING LIMITS THAT MEET CITY
 DETAILS.
  
 9. PROVIDE STRIPING PLAN FOR DISTURBED PAVEMENT AREAS.
  
  
 THE FOLLOWING COMMENTS MUST BE ADDRESSED PRIOR TO
 ISSUANCE OF CONSTRUCTION AUTHORIZATION INCLUDING
 BUILDING PERMITS AND ENGINEERING DEVELOPMENT APPROVAL.
  
 1. DRAINAGE SYSTEM TO BE DESIGNED TO MEET SFWMD ERP
 CRITERIA INCLUDING PEAK FLOW ATTENUATION. STORMWATER
 CALCULATIONS WILL BE REVIEWED WITH THE ENGINEERING
 PERMIT SUBMITTAL.
  
 2. PROVIDE COPY OF SFWMD ERP PERMIT BEFORE START OF
 CONSTRUCTION.
  
 3. PROVIDE EROSION AND SEDIMENT CONTROL PLAN WITH THE
 ENGINEERING PERMIT SUBMITTAL.
  
 TRACY WARD, PE
 SENIOR STORMWATER ENGINEER
 ENGINEERING SERVICES DEPARTMENT
 561-494-1120 (O)
 561-351-0510 (M)
 [email protected]
  

Review Stop SURVEY SURVEYING
Rev No 2 Status F Date 01-06-2023 Cont ID  
Sent By vnoel Date 01-06-2023 Time 07:05 Rev Time 0.00
Received By vnoel Date   Time   Sent To  
Notes
2023-01-06 07:31:301. SURVEY DESCRIPTION DOES NOT INCLUDE 10' PLATTED
 SERVICE STREET. MAY HAVE BEEN ABANDONED PER DB 1166 P
 119. PLEASE PROVIDE COPY.
 2. PREVIOUS COMMENTS NOTED AS IN PROGRESS. WILL NEED TO
 REVIEW WHEN COMPLETED/SUBMITTED.

Review Stop SURVEY SURVEYING
Rev No 1 Status F Date 09-06-2022 Cont ID  
Sent By vnoel Date 09-06-2022 Time 11:41 Rev Time  
Received By vnoel Date   Time   Sent To  
Notes
2022-09-06 11:55:431. SURVEY NOT SIGNED AND SEALED.
 2. REPLAT WILL BE REQUIRED. UNDERLYING EASEMENTS WILL
 NEED TO BE ABANDONED.
 3. NEED APPROVAL FROM FDOT AS TO MAINTENANCE OF
 SIDEWALK OUTSIDE OF RIGHT-OF-WAY OR WILL BE OWNER'S
 RESPONSIBILITY.
 4. MMOA WITH FDOT WILL BE REQUIRED FOR IMPROVEMENTS IN
 DIXIE HWY. DEVELOPER'S AGREEMENT WILL BE REQUIRED WITH
 CITY FOR ASSIGNMENT OF MMOA AND MAINTENANCE OF SIDE
 STREET IMPROVEMENTS.
 5. ADDITIONAL SIDEWALK OUTSIDE OF R/W ON SIDE STREETS
 TO BE MAINTAINED BY DEVELOPER.
 6. MORE DETAIL WILL BE NEED IN AREAS OF PROPOSED
 METERS/BACKFLOWS/LANDSCAPING.

Review Stop TRAFFIC TRAFFIC ENGINEERING
Rev No 2 Status F Date 12-13-2022 Cont ID  
Sent By   Date 12-13-2022 Time   Rev Time 0.00
Received By   Date 12-13-2022 Time   Sent To  
Notes
2022-12-13 12:02:50TRAFFIC COMMENTS
 1) PARTIALLY SATISFIED. GIVEN THE CHANGE IN LAND USE
 INTENSITY AND DRIVEWAY ACCESS POINTS, PROVIDE AN
 UPDATED COUNTY TPS LETTER, ONCE RECEIVED
 2) SATISFIED. A METHODOLOGY MEETING SHOULD BE SCHEDULED
 TO DISCUSS A REVISED TRAFFIC STUDY, AS THE LATEST ONE
 IS BASED ON OLD DATA COLLECTION, AS WELL AS PEDESTRIAN
 CROSSING STUDIES FOR ENHANCED MARKED CROSSWALK ACROSS
 DIXIE HWY AT BARCELONA RD AND CORDOVA RD
 3) PARTIALLY SATISFIED. DEPENDING ON THE OUTCOME OF THE
 TRAFFIC STUDIES AND PARKING REQUIREMENTS,
 TRANSPORTATION DEMAND MANAGEMENT (TDM) MEASURES, ROAD
 SAFETY IMPROVEMENTS AND CONTRIBUTION TO FUTURE TRANSIT
 OPERATIONS MAY BE NEGOTIATED. TO BE FURTHER DISCUSSED
 4) PLEASE INSERT FIGURE, TABLE AND PAGE NUMBERS/LETTERS
 FOR EASE OF REFERENCE
 5) PROVIDE THE LATEST SITE PLAN IN THE TRAFFIC STUDY,
 PROPERLY DATED
 6) SITE ACCESS AND ON-SITE CIRCULATION PARAGRAPH NEEDS
 BETTER ELABORATION OR CORRECTION, AS IT DOES NOT SEEM
 TO DEPICT LATEST SITE PLAN. PLEASE CLEARLY INDICATE THE
 DRIVEWAY TYPOLOGY (I.E. PUBLIC, SERVICE, ONE-WAY,
 FULL-ACCESS) IN THE TURNING MOVEMENT FIGURE
 7) VALET OPERATIONAL ANALYSIS NEEDS TO PROPERLY
 REFERENCE FIGURES (I.E. NUMBER/LETTER), AND LEGEND
 SHOWCASING AND DESCRIBING ALL USED COLORS (I.E. WHAT IS
 THE GREEN PATH?)
 8) PLEASE SHOWCASE VALET VEHICLES PATHS TO/FROM THE
 GARAGE SPACES
 9) PLEASE PROVIDE REALISTIC CALCULATIONS OF VALET
 DRIVING/WALKING TIMES TO/FROM THE STALLS/PODIUM
 10) CLEARLY MARK THE VALET PICK-UP AND DROP-OFF AREAS
  
 SITE COMMENTS
 11) PARTIALLY SATISFIED. PROVIDE A CLEAN TRANSPORTATION
 SPECIFIC SITE PLAN FOR THE GROUND FLOOR. SHOWCASING
 TRANSPORTATION RELATED FEATURES (E.G. ROADWAY WIDTHS,
 DRIVING AISLES, PARKING STALLS, SIDEWALK, CURB, GUTTER,
 DRIVEWAY, GATES, CROSSWALKS, VISIBILITY TRIANGLE,
 CORNER & DRIVEWAY SEPARATION DISTANCES, SLOPES, ETC.)
 PROPERLY LABELED AND DIMENSIONED. THE SITE PLAN SHOULD
 BE NAMED T-1.0. MISSING SEVERAL DIMENSIONS. THIS IS A
 TRANSPORTATION REVIEW: SIDEWALK WALKABLE AREA, TRAVEL
 LANES, DRIVEWAY AISLES, CURB-TO-CURB ROADWAY DIMENSIONS
 ARE ALL IMPORTANT AND MOSTLY MISSING, WHILE SETBACK
 DISTANCES ARE SEMI-USELESS
 12) NOT SATISFIED. IN THE T-1.0 SITE PLAN, PLEASE
 SHOWCASE BASIC CURB DETAILS (E.G. DRIVEWAY, CURB CUTS,
 PAVEMENT MARKINGS, PARKING STALLS, ETC.) ON THE
 OPPOSITE SIDE OF THE ROADS SURROUNDING THE PROPOSED
 DEVELOPMENT. MISSING CURB DETAILS FOR THE NORTH SIDE OF
 FLAMINGO DRIVE, WEST SIDE OF DIXIE HIGHWAY, SOUTH SIDE
 OF CORDOVA RD
 13) NOT SATISFIED. PROVIDE A SIGNAGE AND PAVEMENT
 MARKING PLAN. INCLUSIVE OF ALL FEATURES WITHIN THE
 PROPOSED DEVELOPMENT AND ALONG ALL ROADS FRONTING THE
 SITE. SUCH PLAN IS PART OF THE TRANSPORTATION REVIEW
 AND SHOULD BE NAMED ACCORDINGLY (E.G. T-1.1 OR T-2.0).
 TRAVEL LANE PAVEMENT MARKINGS ARE MISSING AS WELL AS
 CURB DETAILS ON THE OPPOSITE OF THE ROADS SURROUNDING
 THE PROPOSED DEVELOPMENT
 14) NOT SATISFIED. SHOWCASE ALL CORNER CLEARANCE AND
 DRIVEWAY SEPARATION DISTANCES. SPECIFY IF ANY MINIMUM
 DISTANCES ARE NOT MET. IN THAT CASE, VARIANCES MAY BE
 NEEDED FOR THE PROPOSED DRIVEWAYS AND ON-STREET PARKING
 STALLS. PER THE FDOT LETTER, PLEASE SHOWCASE THE
 50-FEET DISTANCE FROM THE ULTIMATE RIGHT-OF-WAY, AS
 WELL AS THE REQUESTED DRIVEWAY DISTANCES. ENGINEERING
 SERVICES WILL THEN ASSESS VARIANCES/WAIVERS
 REQUIREMENTS, IF ANY
 15) NOT SATISFIED. PROVIDE AUTOTURN ANALYSIS FOR
 GARBAGE TRUCK AND/OR SERVICE VEHICLES DRIVING IN AND
 OUT OF THE PROPOSED DEVELOPMENT WITH VEHICLE DYNAMIC
 ENVELOPES AND WHEEL PATHS CLEARLY DISTINCT AND DEFINED
 IN DIFFERENT COLORS. SITE PLAN(S) CONTAINING THE
 ANALYSIS ARE PART OF THE TRANSPORTATION REVIEW AND
 SHOULD BE NAMED ACCORDINGLY (E.G. T1.2, T-3.0). PLEASE
 ADDRESS THE COMMENT PROPERLY; REPEATING THEM: TWO
 DIFFERENT COLORS FOR VEHICLE WHEEL PATHS AND DYNAMIC
 ENVELOPE. SAMPLE AUTOTURN ANALYSIS CAN BE PROVIDED, IF
 REQUESTED, SO TO AVOID FURTHER MISUNDERSTANDINGS
 16) SATISFIED. PROVIDE ENGINEERING REFERENCE AND SPECS
 SHEETS FOR EACH OF THE PROPOSED TRANSPORTATION FEATURES
 (E.G. CURB, RAMP, GATE, SIGNAGE, PAVEMENT MARKING,
 SIGNAL, ETC.)
 17) PARTIALLY SATISFIED. PROVIDE A PARKING TABLE
 SHOWCASING THE NUMBER OF REQUIRED AND PROVIDED PARKING
 SPACES, INCLUSIVE OF ADA AND BICYCLE ONES. IN THE TABLE
 SPECIFY THE REQUIRED AND PROVIDED VAN ACCESSIBLE
 PARKING STALLS
 18) NOT SATISFIED. IN THE PAVEMENT, MARKING & SIGN
 PLAN, PROVIDE A TABLE SHOWCASING THE NUMBER OF EXISTING
 AND PROPOSED ON-STREET PARKING STALLS. PROVIDE THE
 NUMBER OF METERED STALLS THAT ARE BEING REMOVED OR
 RELOCATED, IF ANY. NO TABLE IS SHOWN IN T1.1
 19) PARTIALLY SATISFIED. ARE THERE ANY GATES PROPOSED?
 IF SO, CLEARLY SHOWCASE THE REQUIRED 20 FEET SETBACK
 DISTANCE FROM THE BACK OF THE SIDEWALK. THE DISTANCE
 FOR THE CORDOVA GATE IS MISSING IN SHEET A1.01, OTHER
 LOCATIONS ARE NOT CLEAR IF A GATE IS THERE OR NOT.
 PLEASE PROVIDE A LIST OF GATES AND THEIR LOCATION.
 20) NOT SATISFIED. ARE THERE ANY BUS STOPS BEING
 IMPACTED? IF SO, DEVELOPER SHALL COORDINATE WITH PALM
 TRAN REGARDING THE TRANSIT STOP RELOCATION AND PROVIDE
 A BUS SHELTER. MAINTENANCE OF THE BUS SHELTER SHALL BE
 DEVELOPERS??? RESPONSIBILITY. PLEASE PROVIDE AN
 ELABORATED RESPONSE, JUST AN ACKNOWLEDGEMENT IS
 INSUFFICIENT; IF MISSING, PLEASE PROVIDE A BUS SHELTER
 21) NOT SATISFIED. PER CITY CODE 94-111(Q)(2):
 ???NON-PARKING RAMPS SHALL NOT EXCEED 16 PERCENT. IF
 THE RAMP IS GREATER THAN 14 PERCENT, A BREAK-OVER
 TRANSITION SHALL BE REQUIRED. THE PREFERRED STANDARD IS
 10 PERCENT FOR NON-PARKING RAMP SLOPES???. PLEASE
 REVISE THE PLANS ACCORDINGLY. NO 16% RAMPS ARE ALLOWED,
 ARCHITECTURAL PLANS STILL SHOW SUCH VALUE. PLEASE
 REVISE, AND CLEARLY MARK/CALL-OUT THE BREAK-OVER
 TRANSITION AREAS.
 22) SATISFIED. PLEASE CLEARLY MARKED THE TURN-AROUND
 SPACE AT EACH DEAD-END OF THE GARAGES
 23) PARTIALLY SATISFIED. PLEASE CLEARLY MARK AND LABEL
 THE VALET PARKING SPACES. TANDEM SPACES ARE VALET ONLY,
 SEVERAL HAVE NOT BEEN MARKED AS SUCH, PLEASE REVISE
 24) SIDEWALK CROSSINGS MUST BE STRAIGHT/ALIGNED, NO
 DIAGONALS. PLEASE CORRECT THE CROSSWALKS BY FLAMINGO,
 CORDOVA AND BARCELONA DRIVEWAYS ACCORDINGLY
 25) SIGNS LEGEND MISSING IN T1.0
 26) THE SERVICE DRIVEWAYS AND DRIVE AISLE BETWEEN
 BARCELONA AND CORDOVA ARE NOT OPERATIONALLY PROPER.
 DRIVEWAYS NEED TO BE BOTH EITHER FULL-ACCESS OR ONE-WAY
 ONLY. HOW DO SERVICE VEHICLES TURN-AROUND IN SUCH TIGHT
 DRIVE AISLE OTHERWISE?
 27) PER CITY CODE SEC 94-111(C)(1): IN THOSE CASES
 WHERE THE SIDE OF ANY STALL IS ADJACENT TO A WALL,
 FENCE, BUILDING, OR OTHER PHYSICAL OBSTRUCTION, THE
 STALL WIDTHS SHALL BE INCREASED BY A MINIMUM OF ONE
 FOOT. WHERE THERE IS AN OBSTRUCTION ON BOTH SIDES OF
 THE STALL, THE STALL WIDTHS SHALL BE INCREASED BY A
 MINIMUM OF TWO FEET. PROVIDE DIMENSIONS FOR EVERY STALL
 NEARBY A WALL OR AN OBSTRUCTION
 28) GIVEN THE HISTORY OF RETAIL/RESTAURANT EMPLOYEES
 AND CUSTOMERS NEGATIVELY IMPACTING RESIDENTIAL
 ON-STREET PARKING ALONG THE S DIXIE CORRIDOR, PLEASE
 PROVIDE A PARKING MANAGEMENT PLAN
 29) PROVIDE A CONSTRUCTION MANAGEMENT PLAN. PLEASE
 REFER TO CITY CODE SEC. 84-246 FOR DETAILS
  
 VALERIO ORICCHIO
 CITY TRANSPORTATION ENGINEER
 561-494-1092
 [email protected]
  
  

Review Stop TRAFFIC TRAFFIC ENGINEERING
Rev No 1 Status F Date 09-08-2022 Cont ID  
Sent By   Date 09-08-2022 Time   Rev Time  
Received By   Date 09-08-2022 Time   Sent To  
Notes
2022-09-08 01:00:38TRAFFIC COMMENTS
 1) GIVEN THE CHANGE IN LAND USE INTENSITY AND DRIVEWAY
 ACCESS POINTS, PROVIDE AN UPDATED COUNTY TPS LETTER
 2) A METHODOLOGY MEETING SHOULD BE SCHEDULED TO DISCUSS
 A REVISED TRAFFIC STUDY, AS THE LATEST ONE IS BASED ON
 OLD DATA COLLECTION, AS WELL AS PEDESTRIAN CROSSING
 STUDIES FOR ENHANCED MARKED CROSSWALK ACROSS DIXIE HWY
 AT BARCELONA RD AND CORDOVA RD
 3) DEPENDING ON THE OUTCOME OF THE TRAFFIC STUDIES AND
 PARKING REQUIREMENTS, TRANSPORTATION DEMAND MANAGEMENT
 (TDM) MEASURES, ROAD SAFETY IMPROVEMENTS AND
 CONTRIBUTION TO FUTURE TRANSIT OPERATIONS MAY BE
 NEGOTIATED
  
 SITE COMMENTS
 4) PROVIDE A CLEAN TRANSPORTATION SPECIFIC SITE PLAN
 FOR THE GROUND FLOOR. SHOWCASING TRANSPORTATION RELATED
 FEATURES (E.G. ROADWAY WIDTHS, DRIVING AISLES, PARKING
 STALLS, SIDEWALK, CURB, GUTTER, DRIVEWAY, GATES,
 CROSSWALKS, VISIBILITY TRIANGLE, CORNER & DRIVEWAY
 SEPARATION DISTANCES, SLOPES, ETC.) PROPERLY LABELED
 AND DIMENSIONED. THE SITE PLAN SHOULD BE NAMED T-1.0
 5) IN THE T-1.0 SITE PLAN, PLEASE SHOWCASE BASIC CURB
 DETAILS (E.G. DRIVEWAY, CURB CUTS, PAVEMENT MARKINGS,
 PARKING STALLS, ETC.) ON THE OPPOSITE SIDE OF THE ROADS
 SURROUNDING THE PROPOSED DEVELOPMENT
 6) PROVIDE A SIGNAGE AND PAVEMENT MARKING PLAN.
 INCLUSIVE OF ALL FEATURES WITHIN THE PROPOSED
 DEVELOPMENT AND ALONG ALL ROADS FRONTING THE SITE. SUCH
 PLAN IS PART OF THE TRANSPORTATION REVIEW AND SHOULD BE
 NAMED ACCORDINGLY (E.G. T-1.1 OR T-2.0)
 7) SHOWCASE ALL CORNER CLEARANCE AND DRIVEWAY
 SEPARATION DISTANCES. SPECIFY IF ANY MINIMUM DISTANCES
 ARE NOT MET. IN THAT CASE, VARIANCES MAY BE NEEDED FOR
 THE PROPOSED DRIVEWAYS AND ON-STREET PARKING STALLS
 8) PROVIDE AUTOTURN ANALYSIS FOR GARBAGE TRUCK AND/OR
 SERVICE VEHICLES DRIVING IN AND OUT OF THE PROPOSED
 DEVELOPMENT WITH VEHICLE DYNAMIC ENVELOPES AND WHEEL
 PATHS CLEARLY DISTINCT AND DEFINED IN DIFFERENT COLORS.
 SITE PLAN(S) CONTAINING THE ANALYSIS ARE PART OF THE
 TRANSPORTATION REVIEW AND SHOULD BE NAMED ACCORDINGLY
 (E.G. T1.2, T-3.0)
 9) PROVIDE ENGINEERING REFERENCE AND SPECS SHEETS FOR
 EACH OF THE PROPOSED TRANSPORTATION FEATURES (E.G.
 CURB, RAMP, GATE, SIGNAGE, PAVEMENT MARKING, SIGNAL,
 ETC.)
 10) PROVIDE A PARKING TABLE SHOWCASING THE NUMBER OF
 REQUIRED AND PROVIDED PARKING SPACES, INCLUSIVE OF ADA
 AND BICYCLE ONES
 11) IN THE PAVEMENT, MARKING & SIGN PLAN, PROVIDE A
 TABLE SHOWCASING THE NUMBER OF EXISTING AND PROPOSED
 ON-STREET PARKING STALLS. PROVIDE THE NUMBER OF METERED
 STALLS THAT ARE BEING REMOVED OR RELOCATED, IF ANY
 12) ARE THERE ANY GATES PROPOSED? IF SO, CLEARLY
 SHOWCASE THE REQUIRED 20 FEET SETBACK DISTANCE FROM THE
 BACK OF THE SIDEWALK
 13) ARE THERE ANY BUS STOPS BEING IMPACTED? IF SO,
 DEVELOPER SHALL COORDINATE WITH PALM TRAN REGARDING THE
 TRANSIT STOP RELOCATION AND PROVIDE A BUS SHELTER.
 MAINTENANCE OF THE BUS SHELTER SHALL BE DEVELOPERS?
 RESPONSIBILITY
 14) PER CITY CODE 94-111(Q)(2): ?NON-PARKING RAMPS
 SHALL NOT EXCEED 16 PERCENT. IF THE RAMP IS GREATER
 THAN 14 PERCENT, A BREAK-OVER TRANSITION SHALL BE
 REQUIRED. THE PREFERRED STANDARD IS 10 PERCENT FOR
 NON-PARKING RAMP SLOPES?. PLEASE REVISE THE PLANS
 ACCORDINGLY
 15) PLEASE CLEARLY MARKED THE TURN-AROUND SPACE AT EACH
 DEAD-END OF THE GARAGES
 16) PLEASE CLEARLY MARK AND LABEL THE VALET PARKING
 SPACES
  
 VALERIO ORICCHIO
 CITY TRANSPORTATION ENGINEER
 561-494-1092
 [email protected]
  
  

Review Stop Z ZONING
Rev No 2 Status F Date 12-27-2022 Cont ID  
Sent By llouie Date 12-27-2022 Time   Rev Time 0.00
Received By llouie Date 12-27-2022 Time   Sent To  
Notes
2022-12-27 14:20:45GENERAL COMMENTS:
  
 1.) AS MENTIONED BY STAFF DURING THE PREAPPLICATION
 MEETING WITH THE APPLICANT, PUBLIC OUTREACH ON THE
 PROPOSED DEVELOPMENT IS CRITICAL (AND PRIOR TO THE
 FORMAL SUBMITTAL OF THE PROJECT). DOCUMENTATION OF ANY
 PUBLIC OUTREACH (AND RESULTS/FEEDBACK FROM THESE
 MEETINGS) WITH THE SURROUNDING NEIGHBORS IS REQUIRED
 AND SHALL BE SUBMITTED TO PLANNING STAFF. [NOT
 ADDRESSED. ALTHOUGH THE COMMENT HAS BEEN ACKNOWLEDGED
 IN THE 11/22/22 RESUBMITTAL PACKET AND THE APPLICANT
 HAS INDICATED ON-GOING OUTREACH, NO DOCUMENTATION ON
 COMMUNITY OUTREACH WAS FORMALLY SUBMITTED.]
  
 2.) THE MAXIMUM ALLOWABLE FAR IS 1.5 (RESIDENTIAL +
 NON-RESIDENTIAL). PLEASE CHECK REVISED CALCULATIONS AND
 FAR DIAGRAM. THERE ARE SOME INCONSISTENCIES AND NOT ALL
 REQUIRED SPACES HAVE BEEN INCLUDED IN THE FAR
 CALCULATIONS.
  
 3.) THE PROJECT DOES NOT APPEAR TO FACTOR IN THE
 BUILDING HEIGHT SETBACK ADJACENT TO RESIDENTIAL ZONING
 DISTRICTS. PER THE ZLDRS, IF A STRUCTURE ABUTS A
 RESIDENTIAL ZONING DISTRICT IN EXCESS OF 30 FT., THE
 FOLLOWING ADDITIONAL SETBACK SHALL BE PROVIDED: A) 1
 FT. OF HEIGHT ABOVE 30 FT. FOR EACH 2 FT. OF SETBACK
 WHEN ABUTTING A SINGLE FAMILY RESIDENTIAL ZONING
 DISTRICT AND B) 1 FT. OF HEIGHT ABOVE 30 FT. FOR EACH 1
 FT OF SETBACK WHEN ABUTTING ANY MULTIFAMILY RESIDENTIAL
 ZONING DISTRICT. THE BUILDING HEIGHT SETBACK IS IN
 ADDITION TO THE MINIMUM SETBACK REQUIREMENTS PROVIDED
 IN ZLDR S.94-145(2). [NOT COMPLETELY ADDRESSED. CHECK
 CALCULATIONS FOR CONSISTENCY.]
  
 4.) ZONING DIAGRAMS MUST INCLUDE REQUIRED AND PROVIDED
 CALCULATIONS TO DEMONSTRATE COMPLIANCE/CLEARLY SHOW HOW
 MUCH IS NEEDED FOR THE WAIVER REQUEST (I.E. OPEN SPACE,
 LANDSCAPE AREA ETC.). THE INFORMATION PROVIDED IS NOT
 CLEAR.
  
 5.) PREVIOUS COMMENTS FROM CYCLE 1 RELATED TO THE
 JUSTIFICATION STATEMENT HAVE NOT BEEN ADDRESSED (I.E.
 INCONSISTENCIES WITH THE WRITTEN INFORMATION TO THE
 INFORMATION PROVIDED IN THE PLANS; JUSTIFICATION OF
 EACH WAIVER AND MITIGATION MEASURES, BENEFITS TO THE
 PUBLIC, ETC.), AS NO REVISED JUSTIFICATION STATEMENT
 WAS INCLUDED IN THE 11/22/22 RESUBMITTAL PACKET.
  
 6.) REQUIRED OWNER'S CONSENT FORMS HAVE NOT BEEN
 PROPERLY EXECUTED. PLEASE ADDRESS. [NOT ADDRESSED. THE
 REQUIRED EXECUTED OWNER???S CONSENT FORMS HAVE NOT BEEN
 INCLUDED IN THE 11/22/22 RESUBMITTAL PACKET.]
  
 7.) A TRAFFIC PERFORMANCE STANDARDS (TPS) REVIEW LETTER
 FROM THE PALM BEACH COUNTY TRAFFIC DIVISION IS REQUIRED
 (561-684-4030). ALL INFORMATION PROVIDED IN THE TPS
 LETTER MUST MATCH THE PROJECT INFORMATION FOR
 CONSISTENCY. [NOT ADDRESSED. NO TPS LETTER PROVIDED IN
 THE 11/22/22 RESUBMITTAL PACKET.]
 INFORMATION PROVIDED IN THE TRAFFIC STUDY AND SHARED
 PARKING STATEMENT IS STILL INCONSISTENT WITH THE
 INFORMATION PROVIDED IN THE PLANS. INFORMATION MUST
 MATCH FOR CONSISTENCY.
  
 8.) A NEW SCAD LETTER FROM THE SCHOOL DISTRICT OF PALM
 BEACH COUNTY IS REQUIRED. THE SCAD LETTER INCLUDED IN
 THE APPLICATION SUBMITTAL CONTAINS OUTDATED INFORMATION
 AND IS EXPIRED. INFORMATION IN THE SCAD LETTER MUST
 MATCH THE PROJECT INFORMATION FOR CONSISTENCY. [NOT
 ADDRESSED. NO UPDATED SCAD LETTER WAS PROVIDED IN THE
 11/22/22 RESUBMITTAL PACKET.]
  
 9.) AN ADDRESS LIST, RADIUS MAP AND EXECUTED ADDRESS
 LIST AFFIDAVIT IS REQUIRED PER THE INSTRUCTION ON PAGE
 4 OF THE 2022 DEVELOPMENT APPLICATION. THIS INFORMATION
 WAS NOT INCLUDED IN THE APPLICATION SUBMITTAL. [NOT
 ADDRESSED. NOT PROVIDED.]
  
 10.) PROVIDE WRITTEN CONFIRMATION THAT THE PUBLIC
 UTILITIES DEPARTMENT HAS REVIEWED THE PROPOSAL FOR
 WATER, SEWAGE TREATMENT, STORM DRAINAGE AND GARBAGE
 COLLECTION SERVICES. PLEASE CONTACT THE CITY OF WEST
 PALM BEACH ENGINEERING SERVICES DEPARTMENT
 (561-494-1117). [NOT ADDRESSED. NO CONFIRMATION LETTER
 WAS PROVIDED WITH THE 11/22/22 RESUBMITTAL PACKET.]
  
 11.) PROVIDE LETTERS FROM ALL PUBLIC UTILITIES
 CONFIRMING THAT THE PROPOSED PROJECT DOES NOT ENCROACH
 INTO THEIR EASEMENTS OR OTHERWISE INTERFERE WITH THE
 PROVISIONS OF THEIR SERVICES. [NOT ADDRESSED. NO
 CONFIRMATION LETTERS FROM ANY PUBLIC UTILITIES WERE
 PROVIDED IN THE 11/22/22 RESUBMITTAL PACKET.]
  
 12.) ALL PLAN SHEETS SHALL MATCH FOR CONSISTENCY. NOT
 ALL PLAN SHEETS MATCH. PLEASE ENSURE ALL PLAN SHEETS
 MATCH PRIOR TO THE RESUBMITTAL. [NOT ADDRESSED. PLANS
 WITHIN THE RESUBMITTAL PACKET SHOW INCONSISTENCIES.]
  
 13.) ADDRESS FOLLOWING COMMENTS FOR THE CIVIL PLAN SET:
 A) TABLE OF CONTENTS DO NOT MATCH AND INCONSISTENT IN
 PAGE NUMBERING (SHEET A0.00 AND C-001). B) TABLE OF
 CONTENTS (SHEET C-001): CONCEPTUAL UTILITY PLAN INSET A
 IS SHEET C-503 (NOT C-501). C) CHECK SPELLING FOR SOUTH
 SOIL EROSION AND SEDIMENT CONTROL PLAN (SHEET C-001).
 D) CONCEPTUAL PAVEMENT MARKING AND SIGNAGE PLAN (BOTH
 NORTH AND SOUTH) AND TRUCK CIRCULATION PLAN (BOTH NORTH
 AND SOUTH) HAVE DUPLICATE PAGE NUMBERING IN THE ACTUAL
 SHEETS.
  
 14.) THE TABLE OF CONTENTS FOR THE CIVIL SET DO NOT
 MATCH AND ARE INCONSISTENT (SHEETA0.00 AND C-001).
  
  
 SITE PLAN COMMENTS:
  
 1.) ADDRESS THE FOLLOWING IN THE OVERALL SITE
 INFORMATION (SHEET A0.01): A) EXISTING FUTURE LAND USE:
 COMMERCIAL EAST (CE) B) PROPOSED FUTURE LAND USE:
 COMMERCIAL EAST (CE)
  
 2.) DUE TO THE COMPLEX NATURE OF THE PROJECT, IT WOULD
 BE HELPFUL TO PROVIDE SEPARATE BUILDING SETBACK
 DIAGRAMS. THIS WOULD HELP TO MINIMIZE/CLARIFY THE
 INFORMATION PROVIDED IN THE DIAGRAMS AND MAKE IT
 EASIER/MORE CLEAR ON THE REVIEWER. THE DIAGRAMS ARE
 CLUTTERED WITH INFORMATION WHICH MAKES IT VERY
 DIFFICULT TO READ.
  
 3.) THE FAR DIAGRAMS DO NOT APPEAR TO CAPTURE ALL AREAS
 THAT SHOULD BE COUNTED TOWARDS THE FAR CALCULATIONS
 (SOME SPACES ARE QUESTIONABLE IN THE FAR CALCULATION).
 PLEASE NOTE THAT THE MAXIMUM ALLOWABLE FAR IS 1.5
 (RESIDENTIAL AND NON-RESIDENTIAL).
  
 4.) BUILDING SETBACKS HAVE BEEN INCORRECTLY MEASURED.
 THE BUILDING SETBACKS SHALL BE MEASURED FROM THE
 PROPERTY LINE TO THE CLOSEST POINT OF THE BUILDING
 WALL. THERE ARE ARCHITECTURAL PROJECTIONS THAT ENCROACH
 WITHIN THE NOTED BUILDING SETBACKS. THESE ARCHITECTURAL
 PROJECTIONS ARE NOT EXEMPT AND SHALL BE COUNTED AS PART
 OF THE PRINCIPAL BUILDING SETBACK.
  
 5.) STRUCTURAL OVERHANGS, INCLUDING BALCONIES, ETC. MAY
 NOT PROJECT MORE THAN 3 FT INTO A SETBACK. SUCH
 ENCROACHMENTS HAVE BEEN INCORRECTLY MEASURED AND
 NOTATED IN THE PLANS. PLEASE ADDRESS FOR CONSISTENCY.
 [ZLDR S.94-305(B)(2)]
  
 6.) THE PLANS NOTE ???EDGE OF TRELLIS??? (SHEET A1.01
 ??? GROUND LEVEL) FOR BOTH BUILDINGS; HOWEVER, NO
 INFORMATION AND DETAILS HAVE BEEN PROVIDED IN THE
 PLANS. IS THIS A NOTE THAT SHOULD BE ELIMINATED FROM
 THE REVISED PLAN SET?
  
 7.) WALL HEIGHT INFORMATION FOR THE FLAMINGO AND
 CORDOVA BUILDINGS SHALL BE PROVIDED IN THE PLANS. THE
 HEIGHT OF THE PROPOSED PRIVACY WALL SHALL BE CONSISTENT
 WITH THE HEIGHT STANDARDS IN ZLDR S.94-302. THIS
 INFORMATION WAS REQUESTED IN STAFF???S PREVIOUS
 COMMENTS; HOWEVER, IT HAS NOT BEEN ADDRESSED.
  
 8.) MIXED USE PROJECT WITH OVER 300 PARKING SPACES
 PROVIDED SHALL HAVE A MAXIMUM OF TWO (2) ACCESS POINTS
 ONTO EACH RIGHT-OF-WAY. PLEASE PROVIDE MORE INFORMATION
 ON THE FPL VAULTS WITHIN THE FLAMINGO BUILDING AND
 WHETHER OR NOT THE VAULTS WILL HAVE VEHICULAR ACCESS
 (LOCATED ALONG FLAMINGO DRIVE). PLEASE NOTE THAT THE
 FLAMINGO BUILDING CURRENTLY HAS 2 ACCESS POINTS ON
 FLAMINGO DRIVE. [S.94-312]
  
 9.) GROUND FLOOR PLAN FOR THE CORDOVA BUILDING SHOWS
 7,624 SQ. FT. FOR THE RETAIL USE, WHICH IS INCONSISTENT
 WITH THE 7,626 SQ. FT. PROVIDED IN THE ZONING DATA AND
 TRAFFIC STUDY. PLEASE ADDRESS FOR CONSISTENCY.
  
 10.) CHECK PARKING CALCULATIONS FOR THE FLAMINGO
 BUILDING (SHEET A0.01). THERE MAY BE AN ERROR IN THE
 CALCULATIONS, AS THE NUMBER OF PARKING SPACES ON EACH
 PARKING LEVEL DOES NOT ADD UP.
  
 11.) THE "ON-STREET" PARKING IN THE SITE PLAN IS
 INCORRECTLY LABELED AS "OFF STREET" PARKING. THESE
 SPACES ARE CLEARLY LOCATED OUTSIDE OF THE PROPERTY
 LINE, AND THEREFORE SHALL BE CORRECTED FOR CONSISTENCY.
  
 12.) LOCATION OF LIGHT POLES (AS PROVIDED IN THE
 PHOTOMETRIC PLAN) ARE NOT SHOWN IN THE SITE PLAN.
 PLEASE SHOW LOCATION OF THE LIGHT FIXTURES AND SETBACKS
 TO DEMONSTRATE CONSISTENCY WITH THE PLANS AND
 COMPLIANCE WITH THE ZLDRS.
  
 13.) PLEASE EXPLAIN THE ENCLOSED LOADING AREA IN THE
 FLAMINGO BUILDING (LEVEL 1). IT DOES NOT MAKE SENSE TO
 PROVIDE A LOADING DRIVE NEXT TO AN ENCLOSED LOADING
 AREA.
  
 14.) THE ENCLOSED NON-AIRCONDITIONED "VESTIBULE" SHALL
 BE COUNTED TOWARDS FAR. [ZLDR 94-145(11)]
  
  
 LANDSCAPING AND BUFFERING REQUIREMENTS:
  
 1.) A PROTECTIVE SCREEN WALL AND LANDSCAPE BUFFER SHALL
 BE PROVIDED ALONG THE PROPERTY LINE ABUTTING A
 RESIDENTIAL ZONING DISTRICT IN ACCORDANCE WITH
 S.94-443(A). COMPLIANCE WITH THIS REQUIREMENT HAS NOT
 BEEN FULLY MET.
  
  
 PARKING COMMENTS:
  
 1.) CHECK PARKING CALCULATIONS PROVIDED IN THE REVISED
 PLANS. THERE APPEARS TO BE INCONSISTENCIES WITH THE
 PARKING CALCULATIONS.
  
 2.) ALTHOUGH IT DOES NOT MAKE SENSE TO PROVIDE AN
 ENCLOSED LOADING AREA NEXT TO THE UNENCLOSED LOADING
 AREA (MORE INFORMATION IS NEEDED). AN AUTO-TURN DIAGRAM
 WILL BE REQUIRED FOR THE ENCLOSED LOADING AREA (IF
 KEPT), AS THE AREA/SPACE APPEARS TO BE VERY TIGHT.
  
 3.) PLEASE IDENTIFY THE LOCATION OF TURNAROUND SPACES
 IN THE PARKING GARAGES WHERE NECESSARY TO ADDRESS
 ADEQUATE VEHICULAR CIRCULATION. [NOT ADDRESSED. NO
 MARKINGS/NOTATIONS HAVE BEEN PROVIDED IN THE PLANS.]
  
 4.) IS THERE ANY ON-STREET PARKING PROPOSED FOR THE
 PROJECT? IF SO, PLEASE PROVIDE MORE INFORMATION (I.E.
 LOCATION, DIMENSIONS, CALCULATIONS, ETC.). [PARTIALLY
 ADDRESSED. ON-STREET PARKING STALLS SHALL BE
 DIMENSIONED TO DEMONSTRATE COMPLIANCE WITH THE
 DIMENSIONAL REQUIREMENTS FOR ON-STREET PARKING.
 DIMENSIONS HAVE NOT BEEN PROVIDED IN THE PLANS.]
  
 5.) A NOTE CLEARLY STATING THAT THE TANDEM PARKING
 SPACES WILL BE CLEARLY MARKED AND RESERVED FOR
 VALET/RESIDENTIAL SHALL BE PROVIDED IN THE PLANS. [NOT
 ADDRESSED. NOTE STILL MISSING IN THE REVISED PLAN SET.]
  
  
 ARCHITECTURAL COMMENTS:
  
 1.) BUILDING HEIGHT INFORMATION INCOMPLETE IN THE
 ELEVATIONS. PLEASE PROVIDE MEASUREMENTS IN ACCORDANCE
 AND CONSISTENT WITH SEC. 94-145 (GENERAL COMMERCIAL
 DISTRICT), SEC. 94-306 (HEIGHT EXCEPTIONS AND SEC.
 94-611 (HEIGHT OF STRUCTURE). [NOT ADDRESSED TO STAFF'S
 STATISFACTION. PLEASE SEE PREVIOUS COMMENTS ABOVE.]
  
 2.) ALL SPACES WITHIN THE REVISED FLOOR PLAN SET SHALL
 BE LABELED TO DETERMINE IF THE SPACES SHALL BE COUNTED
 TOWARDS THE FAR. SOME (ENCLOSED) SPACES DO NOT HAVE
 LABELS/ARE NOT CLEARLY IDENTIFIED.
  
  
 LIGHTING/PHOTOMETRIC COMMENTS:
  
 1.) A PHOTOMETRIC PLAN HAS BEEN SUBMITTED WITH THE
 11/22/22 RESUBMITTAL PACKET; HOWEVER, THE FOLLOWING
 SHALL BE ADDRESSED TO DEMONSTRATE CONSISTENCY WITH THE
 PLANS AND THE ZLDRS: A) ALTHOUGH THERE'S A NOTE ON
 SHEETS PH1 AND PH2 OF THE PHOTOMETRIC SET STATING THAT
 THE LIGHT POLE FIXTURES WILL BE SETBACK A MINIMUM OF 5
 FT. FROM THE PROPERTY LINE, THE PLAN ALSO SHOWS THE
 LOCATION OF THE PROPOSED LIGHT POLES, WHICH ARE CLEARLY
 WITHIN 5 FT. OF THE PROPERTY LINE. PLEASE ADDRESS THIS
 CONFLICT. IF THE LIGHT POLES CANNOT BE LOCATED OUTSIDE
 OF THE MINIMUM REQUIRED SETBACK FROM THE PROPERTY LINE,
 THE APPLICANT SHALL EITHER REMOVE THE POLE FIXTURE OR
 REQUEST A WAIVER TO THE SETBACK REQUIREMENT. B) THE
 SETBACK DIMENSION OF THE LIGHT POLE TO THE PROPERTY
 LINE SHALL BE CLEARLY DEPICTED IN THE PHOTOMETRIC PLAN.
 C) THE PHOTOMETRIC PLAN DOES NOT SHOW THE PHOTOMETRIC
 SPILLOVER BEYOND THE PROPERTY LINES OF THE PROJECT SITE
 AS REQUESTED. GIVEN THE LIGHTING INFORMATION PROVIDED,
 THE PLAN SHOULD NOT HAVE AN ISSUE PROVIDING THE
 LIGHTING SPILLOVER TO DEMONSTRATE COMPLIANCE.
  
  
 SIGNAGE COMMENTS:
  
 1.) THE PREVIOUS COMMENT ON SIGNAGE HAS NOT BEEN
 ADDRESSED (CYCLE 1 ??? 9/6/22). THE 11/22/22 RESPONSE
 TO STAFF???S COMMENTS AND WAIVER TABLE (SHEET A0.01)
 STATES THAT A WAIVER TO SIGNAGE IS BEING REQUESTED;
 HOWEVER, NO REVISED JUSTIFICATION STATEMENT HAS BEEN
 PROVIDED WITH THE 11/22/22 RESUBMITTAL PACKET, AND THE
 DEVELOPMENT PLAN DOES NOT PROVIDE ANY SPECIFIC DETAILS
 ON THE SIGN WAIVER REQUEST. AT THIS TIME, THE APPLICANT
 MUST HAVE INFORMATION ON THE SPECIFIC WAIVER(S) TO
 SIGNAGE FOR THE PROJECT. THE WAIVER CANNOT BE
 GENERALIZED. IT MAY BE HELPFUL TO GENERATE A SIGN
 PROGRAM FOR THE PROJECT.
  
  
 INSTRUCTIONS FOR RESUBMITTAL:
  
 * PLEASE PROVIDE RESPONSES TO REVIEW COMMENTS IN
 WRITTEN FORMAT.
  
 * MAKE SURE ALL PLANS MATCH FOR CONSISTENCY!
  
 * WHEN RESUBMITTING, PLEASE PROVIDE A MINIMUM OF FOUR
 (4) FULL SIZE PAPER COPIES AND ONE SET IN 11 INCHES X
 17 INCHES, AND AN ELECTRONIC COPY OF ALL PLANS AND
 DOCUMENTS. THREE (3) HARD COPY SETS SHALL BE PROVIDED
 IN FULL COLOR.
  
 * ANY CHANGES TO THE RESUBMITTED PLANS MAY RESULT IN
 ADDITIONAL COMMENTS.
  
 * PLEASE NOTE YOU WILL BE PERMITTED ONE (1) RESUBMITTAL
 AT NO ADDITIONAL COST. IF PREVIOUSLY-ISSUED COMMENTS
 CONTINUE TO NOT BE SUFFICIENTLY ADDRESSED, THE
 APPLICANT WILL BE ASSESSED A RESUBMITTAL FEE. SUCH FEE
 WILL BE 20% OF THE ORIGINAL APPLICATION FEE ($600).
  
 * CONTACT LINDA LOUIE @ (561) 822-1458 IF THERE ARE
 QUESTIONS.
  

Review Stop Z ZONING
Rev No 1 Status F Date 09-06-2022 Cont ID  
Sent By llouie Date 09-06-2022 Time   Rev Time  
Received By llouie Date 09-06-2022 Time   Sent To  
Notes
2022-09-06 09:20:00*** THE PROJECT AREA DOES NOT MATCH THE INFORMATION
 PROVIDED IN THE SIGNED AND SEALED SURVEY AND AS A
 RESULT, THE CALCULATIONS FOR THE PROJECT ARE
 INCONSISTENT AND EXCEEDS THE STANDARDS/REQUIREMENTS OF
 THE CITY'S COMPREHENSIVE PLAN AND ZONING AND LAND
 DEVELOPMENT REGULATIONS (ZLDRS). ADDITIONALLY, PER SEC.
 94-207(A)(1)(B), THE DENSITY AND INTENSITY OF A PROJECT
 CANNOT EXCEED THE DENSITY AND INTENSITY STANDARDS
 PROVIDED IN COMPREHENSIVE PLAN, FUTURE LAND USE ELEMENT
 POLICY 1.1.3. ***
  
 GENERAL COMMENTS:
  
 1.) AS MENTIONED BY STAFF DURING THE PRE-APPLICATION
 MEETING WITH THE APPLICANT, PUBLIC OUTREACH ON THE
 PROPOSED DEVELOPMENT PROJECT IS CRITICAL (AND PRIOR TO
 THE FORMAL SUBMITTAL OF THE PROJECT). DOCUMENTATION OF
 ANY PUBLIC OUTREACH (AND RESULTS/FEEDBACK FROM THESE
 MEETINGS) WITH THE SURROUNDING NEIGHBORS IS REQUIRED
 AND SHALL BE SUBMITTED TO PLANNING STAFF.
  
 2.) THE MAXIMUM ALLOWABLE FAR IS 1.5 (RESIDENTIAL +
 NON-RESIDENTIAL). BASED ON THE INFORMATION PROVIDED IN
 THE PLAN SET, THE PROPOSED FAR FOR THE PROJECT IS 1.62,
 WHICH EXCEEDS THE MAXIMUM AND IS NOT PERMITTED. PLEASE
 ADJUST PROJECT TO COMPLY. [ZLDR S.94-145(8)(D)]
  
 3.) THE MAXIMUM ALLOWABLE RESIDENTIAL DENSITY HAS BEEN
 EXCEEDED. PER ZLDR S.94-145(9)(B), THE MAXIMUM
 ALLOWABLE DENSITY IS 32.27 DU/ACRE. THE PROPOSED
 PROJECT CURRENTLY HAS A DENSITY OF 32.7 DU/ACRE WHICH
 IS NOT PERMITTED. PLEASE ADDRESS.
  
 4.) THE PROJECT DOES NOT APPEAR TO FACTOR IN THE
 BUILDING HEIGHT SETBACK ADJACENT TO RESIDENTIAL ZONING
 DISTRICTS. PER THE ZLDRS, IF A STRUCTURE ABUTS A
 RESIDENTIAL ZONING DISTRICT IN EXCESS OF 30 FT., THE
 FOLLOWING ADDITIONAL SETBACK SHALL BE PROVIDED: A) 1
 FT. OF HEIGHT ABOVE 30 FT. FOR EACH 2 FT. OF SETBACK
 WHEN ABUTTING A SINGLE-FAMILY RESIDENTIAL ZONING
 DISTRICT AND B) 1 FT. OF HEIGHT ABOVE 30 FT. FOR EACH 1
 FT. OF SETBACK WHEN ABUTTING ANY MULTIFAMILY
 RESIDENTIAL ZONING DISTRICT. THE BUILDING HEIGHT
 SETBACK IS IN ADDITION TO THE MINIMUM SETBACK
 REQUIREMENTS PROVIDED IN ZLDR S.94-145(2). [ZLDR
 S.94-145(6)]
  
 5.) PROJECT INFORMATION IS INCONSISTENT THROUGHOUT THE
 JUSTIFICATION STATEMENT. PLEASE REVISE JUSTIFICATION
 STATEMENT TO ADDRESS ANY CORRECTIONS/INACCURACIES.
  
 6.) JUSTIFICATION ON THE REQUESTED WAIVERS NEED TO BE
 EXPANDED TO IDENTIFY ANY MITIGATION MEASURES AND
 BENEFITS OF EACH WAIVER REQUEST TO THE GENERAL
 PUBLIC/SURROUNDING NEIGHBORHOOD.
  
 7.) TABLES PRESENTED WITHIN THE PLAN SET DOES NOT
 EFFECTIVELY PRESENT INFORMATION AND CAN BE IMPROVED
 AND/OR SIMPLIFIED. ALSO, DATA/CALCULATIONS PRESENTED
 ARE EITHER INCORRECT/INCOMPLETE OR DIFFICULT TO
 UNDERSTAND. PLEASE CONTACT STAFF FOR EXAMPLES ON DATA
 PRESENTATION (IF NECESSARY).
  
 8.) PLANNED DEVELOPMENTS ARE NOT PERMITTED IN HISTORIC
 DISTRICTS. THEREFORE, ALL PD ASSOCIATED ZONING
 REQUIREMENTS MUST BE ADDRESSED ON THE PARCEL(S) OF THE
 PROPOSED CPD. THERE APPEARS TO BE A PROPOSED LANDSCAPE
 BUFFER ON THE PROPERTY OF 309 BARCELONA (WITHIN THE EL
 CID HISTORIC DISTRICT). THIS IS NOT PERMITTED. [ZLDR
 S.94-207(A)(2)]
  
 9.) REQUIRED OWNER'S CONSENT FORMS HAVE NOT BEEN
 PROPERTY EXECUTED. PLEASE ADDRESS.
  
 10.) A TRAFFIC PERFORMANCE STANDARDS (TPS) REVIEW
 LETTER FROM THE PALM BEACH COUNTY TRAFFIC DIVISION IS
 REQUIRED (561-684-4030). ALL INFORMATION PROVIDED IN
 THE TPS LETTER MUST MATCH PROJECT INFORMATION FOR
 CONSISTENCY.
  
 11.) INFORMATION IN THE TRAFFIC STUDY (PREPARED BY
 BRYAN G. KELLEY, P.E., OF SIMMONS AND WHITE, DATED
 8/8/2022) IS INCONSISTENT WITH THE PROJECT INFORMATION
 PRESENTED IN THE PLAN SET (I.E. BUILDING SQUARE
 FOOTAGE; ALSO, RESIDENTIAL DENSITY PROPOSED (59 UNITS)
 IS NOT PERMITTED AS IT EXCEEDS THE MAXIMUM ALLOWABLE
 DENSITY). PLEASE ADDRESS FOR CONSISTENCY.
  
 12.) INFORMATION IN THE SHARED PARKING STATEMENT
 (PREPARED BY BRYAN G. KELLEY, P.E., OF SIMMONS AND
 WHITE, DATED 8/8/2022) IS INCONSISTENT WITH THE PROJECT
 INFORMATION PRESENTED IN THE PLAN SET (I.E. BUILDING
 SQUARE FOOTAGE; ALSO, RESIDENTIAL DENSITY PROPOSED (59
 UNITS) IS NOT PERMITTED AS IT EXCEEDS THE MAXIMUM
 ALLOWABLE DENSITY). PLEASE ADDRESS FOR CONSISTENCY.
  
 13.) A NEW SCAD LETTER FROM THE SCHOOL DISTRICT OF PALM
 BEACH COUNTY IS REQUIRED. THE SCAD LETTER INCLUDED IN
 THE APPLICATION SUBMITTAL CONTAINS OUTDATED INFORMATION
 AND IS EXPIRED. INFORMATION IN THE SCAD LETTER MUST
 MATCH THE PROJECT INFORMATION FOR CONSISTENCY.
  
 14.) THE HEIGHT OF STRUCTURES, INCLUDING EXEMPT ITEMS
 OR EQUIPMENT, SHALL NOT EXCEED LIMITATIONS PRESCRIBED
 BY THE FEDERAL AVIATION ADMINISTRATION (FAA) WITHIN
 DESIGNATED FLIGHT APPROACH PATTERNS OF AIRPORTS OR
 RELATED AVIATION FACILITIES. ALTHOUGH STAFF DOES NOT
 BELIEVE THIS WILL BE AN ISSUE, PLEASE PROVIDE A LETTER
 FROM THE FAA INDICATING THAT THE PROPOSED PROJECT IS NO
 HAZARD TO AIR NAVIGATION. [ZLDR S.94-306(B)]
  
 15.) AN ADDRESS LIST, RADIUS MAP AND EXECUTED ADDRESS
 LIST AFFIDAVIT IS REQUIRED PER THE INSTRUCTIONS ON PAGE
 4 OF THE 2022 DEVELOPMENT APPLICATION. THIS INFORMATION
 WAS NOT INCLUDED IN THE APPLICATION SUBMITTAL.
  
 16.) PROVIDE WRITTEN CONFIRMATION THAT THE PUBLIC
 UTILITIES DEPARTMENT HAS REVIEWED THE PROPOSAL FOR
 WATER, SEWAGE TREATMENT, STORM DRAINAGE AND GARBAGE
 COLLECTION SERVICES. PLEASE CONTACT THE CITY OF WEST
 PALM BEACH ENGINEERING SERVICES DEPARTMENT
 (561-494-1117).
  
 17.) PROVIDE LETTERS FROM ALL PUBLIC UTILITIES
 CONFIRMING THAT THE PROPOSED PROJECT DOES NOT ENCROACH
 INTO THEIR EASEMENTS OR OTHERWISE INTERFERE WITH THE
 PROVISIONS OF THEIR SERVICES.
  
 18.) PER SEC. 94-207(B)(10)(C), THE APPLICATION SHALL
 INCLUDE THE PROPOSED SCHEDULE OF DEVELOPMENT WHICH
 IDENTIFIES THE ANTICIPATED PROJECT START AND COMPLETION
 DATES, STAGES OF DEVELOPMENT (IF ANY), AND THE AREA AND
 LOCATION OF COMMON OPEN SPACE TO BE PROVIDED AT EACH
 STAGE. THIS INFORMATION HAS NOT BEEN PROVIDED IN THE
 APPLICATION SUBMITTAL.
  
 19.) ALL PLAN SHEETS SHALL MATCH FOR CONSISTENCY. NOT
 ALL PLAN SHEETS MATCH. PLEASE ENSURE ALL PLAN SHEETS
 MATCH PRIOR TO THE RESUBMITTAL.
  
  
 SITE PLAN COMMENTS:
  
 1) ANY PETITION FOR A PLANNED DEVELOPMENT SHALL BE
 ACCOMPANIED BY A MASTER DEVELOPMENT PLAN OF THE
 DEVELOPMENT COMPRISED OF THE ELEMENTS LISTED IN SEC.
 94-207(B)(9) AND THE SITE PLAN CHECKLIST ON PAGE 16/30
 OF THE 2022 DEVELOPMENT APPLICATION. THE MASTER
 DEVELOPMENT PLAN IS REQUIRED TO SHOW THE PROJECT IN
 RELATIONSHIP TO ITS IMMEDIATE SURROUNDINGS AND WITH
 EXISTING STRUCTURES. IT IS ALSO CRITICAL TO INCLUDE ALL
 RELEVANT INFORMATION/DATA IN THE PLAN (I.E.
 BUILDING/STRUCTURAL SETBACKS, CRITICAL DIMENSIONS,
 BICYCLE PARKING, ZONING AND WAIVER TABULARS, ETC.).
  
 2.) A WAIVER TABULAR, SPECIFYING EACH WAIVER REQUESTED
 FOR THE PROJECT AND ANY PERTINENT INFORMATION (I.E.
 REFERENCE CODE SECTION, INFORMATION ON
 REQUIRED/PROPOSED, ETC.) SHALL BE INCLUDED IN THE PLAN
 SET FOR REFERENCE.
  
 3.) THE FOLLOWING SHEETS ARE MISSING FROM THE PLAN SET
 (REFERENCE: COVER SHEET A0.00): A) OPEN SPACE DIAGRAM
 (A0.04) B) BUILDING SECTION (A3.01)
  
 4.) MORE INFORMATION IS REQUIRED ON THE CALCULATIONS
 FOR THE MAXIMUM LOT COVERAGE BY BUILDINGS (MAXIMUM IS
 60%; PROVIDED 68%). ILLUSTRATE WITH DIAGRAMS WHERE
 NECESSARY. [ZLDR S.94-145(3)]
  
 5.) MORE INFORMATION IS REQUIRED ON THE CALCULATIONS
 FOR MAXIMUM LOT COVERAGE BY IMPERMEABLE SURFACE
 (MAXIMUM IS 85%); NO INFORMATION ON THE PROVIDED
 IMPERVIOUS SURFACE COVERAGE. ILLUSTRATE WITH DIAGRAMS
 WHERE NECESSARY TO DEMONSTRATE COMPLIANCE. [ZLDR
 S.94-145(4)]
  
 6.) MORE INFORMATION IS REQUIRED ON THE MINIMUM OPEN
 SPACE AND LANDSCAPE AREA CALCULATIONS. ILLUSTRATE WITH
 DIAGRAMS WHERE NECESSARY. [ZLDR S.94-145(5)]
  
 7.) PLANS MUST CLEARLY SHOW THE PROVIDE BUILDING
 SETBACKS FOR THE PROJECT. THE BUILDING SETBACK IS
 MEASURED FROM THE OUTSIDE WALL(S) OF THE BUILDING TO
 THE PROPERTY LINE(S). ADDITIONALLY, INCLUDE DIMENSIONS
 FOR ALL STRUCTURAL OVERHANGS, INCLUDING BUT NOT LIMITED
 TO BALCONIES, CORNICES, BUTTERS, EAVES AND ROOF
 OVERHANG PROJECTIONS; STRUCTURAL OVERHANGS SHALL NOT
 EXTEND FARTHER THAN 33 FT. INTO A REQUIRED SETBACK.
 [ZLDR S.94-305(B)(2)]
  
 8.) ARCHITECTURAL ELEVATIONS SHOW AWNINGS. AWNINGS
 SHALL NOT PROJECT MORE THAN 4 FT. INTO ANY REQUIRED
 SETBACK OR BE SUPPORTED BY ANY MEANS OTHER THAN
 ATTACHMENT TO THE BUILDING. IF AWNINGS ARE PROPOSED,
 THE AWNING MUST BE CLEARLY LABELED/IDENTIFIED IN THE
 PLANS; THE OUTLINE FOR THE AWNING MUST HAVE DIMENSIONS
 TO DEMONSTRATE COMPLIANCE WITH THE ZLDRS. ADDITIONALLY,
 IF THE AWNING ENCROACHES BEYOND THE PROPERTY LINE AND
 INTO A RIGHT-OF-WAY, ADDITIONAL APPROVALS FROM THE
 REGULATING AGENCY WILL BE REQUIRED. [ZLDR
 S.94-305(B)(5)]
  
 9.) AT ANY ROAD INTERSECTIONS, VISIBILITY SHALL NOT BE
 OBSCURED BY THE CONSTRUCTION, PLACEMENT, OR MAINTENANCE
 OF A STRUCTURE WALL, SIGN, FENCE, BERM, PLANT MATERIAL,
 SHRUBS OR ANY SIMILAR ITEM BETWEEN 18 INCHES OR 8 FT.
 WITHIN THE VISIBILITY TRIANGLE. BASED ON STAFF?S REVIEW
 OF THE ARCHITECTURAL ELEVATIONS, THERE ARE AWNINGS
 ILLUSTRATED ON THE BUILDING WHICH APPEARS TO ENCROACH
 INTO THE VISIBILITY TRIANGLE. PLEASE ADDRESS FOR
 CONSISTENCY WITH THE ZLDRS AND PLAN SET. [ZLDR
 S.94-305(E)]
  
 10.) IN NON-RESIDENTIAL DISTRICTS, NO FENCE, HEDGE OR
 WALL SHALL EXCEED 8 FT. IN HEIGHT WITHIN THE REQUIRED
 SIDE AND REAR SETBACKS. FENCES/WALLS SHALL NOT EXCEED
 48 INCHES IN HEIGHT WITHIN THE REQUIRED FRONT SETBACK.
 SHOW HEIGHT (AND DETAIL, IF APPLICABLE) OF ALL WALL
 SEGMENTS PROPOSED WITHIN THE PROJECT TO DEMONSTRATE
 COMPLIANCE. [ZLDR S.94-302(C)]
  
 11.) THE MAXIMUM NUMBER OF ACCESS POINTS TO A PUBLIC
 RIGHT-OF-WAY IS TWO (2). THERE APPEARS TO BE THREE (3)
 ACCESS POINTS FOR THE EL FLAMINGO BUILDING ALONG
 FLAMINGO DRIVE. PLEASE ADDRESS. [ZLDR S.94-312(1)(A)]
  
 12.) THE PROJECT DOES NOT COMPLY WITH THE MINIMUM
 REQUIREMENTS FOR SEPARATION OF ACCESS POINTS. PLEASE
 ADDRESS. [ZLDR S.94-312(2)]
  
  
 PARKING COMMENTS:
  
 1.) PARKING CALCULATIONS REQUIRE FURTHER BREAKDOWN OF
 USES (I.E. NUMBER OF SEATS, SQUARE FOOTAGES, RESERVED
 SPACES, ETC.). TO CLEARLY SHOW PARKING REQUIREMENTS AND
 HOW THEY?VE BEEN MET. ALSO, THE PARKING CALCULATIONS
 PROVIDED ARE INACCURATE AND MUST BE CORRECTED FOR
 ACCURACY (I.E. RETAIL SQUARE FOOTAGE; WHERE?S THE
 GALLERY?).
  
 2.) SHARED PARKING ANALYSIS (PREPARED BY BRYAN G.
 KELLEY, P.E., OF SIMMONS & WHITE, DATED 8/8/2022) AND
 CALCULATIONS APPEAR TO BE INCONSISTENT WITH THE
 REQUIREMENTS OF SEC. 94-484. ADDITIONALLY, PARKING
 SPACES WHERE ARE RESERVED FOR USE BY SPECIFIED
 INDIVIDUALS OR CLASSES OF INDIVIDUALS SHALL NOT BE
 COUNTED TOWARDS MEETING THE SHARED PARKING
 REQUIREMENTS. PLEASE ADDRESS FOR CONSISTENCY WITH THE
 ZLDRS. [ZLDR S.94-484]
  
 3.) PLEASE IDENTIFY THE LOCATION OF TURNAROUND SPACES
 IN THE PARKING GARAGE(S) WHERE NECESSARY TO ADDRESS
 ADEQUATE VEHICULAR CIRCULATION.
  
 4.) PROVIDE AN AUTO-TURN DIAGRAM FOR LOADING. PLEASE
 NOTE THAT CONFIGURATION WHICH REQUIRE BACKING DIRECTLY
 ONTO A STREET FROM A PARKING OR LOADING SPACE FOR A
 MIXED-USE PROJECT IS PROHIBITED IN ALL RESIDENTIAL AND
 NON-RESIDENTIAL ZONING DISTRICTS. THERE SHALL BE A
 MINIMUM OF 10 FT. BETWEEN ACCESS DRIVES. ALSO, PLEASE
 NOTE THAT THE JUSTIFICATION STATEMENT MENTIONS THE
 AUTO-TURN DIAGRAM WHICH HAS NOT BEEN FOUND. [ZLDR
 S.94-485(J)]
  
 5.) ALL NECESSARY DIMENSIONS IN THE PARKING LAYOUT
 SHALL BE PROVIDED IN THE PLANS TO DEMONSTRATE
 COMPLIANCE WITH THE ZLDRS. [ZLDR S.94-485(N)(2)]
  
 6.) IN ADDITION TO THE PARKING LAYOUT FOR THE PROJECT,
 A PARKING STALL DETAIL IN COMPLIANCE WITH THE MINIMUM
 REQUIREMENTS OF THE ZLDRS SHALL BE PROVIDED. THE DETAIL
 MUST BE INCLUDED TO DEMONSTRATE COMPLIANCE WITH THE
 ZLDRS. [ZLDR S.94-485(N)]
  
 7.) ARE ANY COMPACT PARKING SPACES PROPOSED IN THE
 PROJECT? IF SO, INFORMATION ON THE COMPACT PARKING
 SPACES SHALL BE PROVIDED/COMPLY WITH THE COMPACT
 PARKING REQUIREMENTS OF THE ZLDRS. [ZLDR S.94-485(N)]
  
 8.) IS THERE ANY ON-STREET PARKING PROPOSED FOR THE
 PROJECT? IF SO, PLEASE PROVIDE MORE INFORMATION (I.E.
 LOCATION, DIMENSIONS, CALCULATIONS, ETC.).
  
 9.) THERE IS INSUFFICIENT INFORMATION PROVIDED ON
 ACCESSIBLE PARKING SPACES. PLEASE PROVIDE CALCULATIONS
 (REQUIRED AND PROPOSED) AND SHOW LOCATION OF ACCESSIBLE
 PARKING SPACES WITHIN THE PLANS TO DEMONSTRATE
 COMPLIANCE/CONSISTENCY WITH THE ZLDRS. [ZLDR
 S.94-485(O)]
  
 10.) REQUIRED/PROPOSED LOADING SPACE
 INFORMATION/CALCULATIONS MISSING FROM THE PLAN SET.
 [ZLDR S.94-485(P)]
  
 11.) BICYCLE PARKING REQUIREMENT FOR THE PROJECT HAS
 NOT BEEN ADDRESSED. THE PLANS MUST SHOW THE
 CALCULATIONS (REQUIRED AND PROVIDED), LOCATION AND
 DETAIL CONSISTENT WITH THE ZLDRS AND THE CITY?S BICYCLE
 PARKING GUIDELINES (CONTACT STAFF FOR DOCUMENT). [ZLDR
 S.94-485(Q)]
  
 12.) WHEEL STOPS ARE ILLUSTRATED FOR ALL TANDEM PARKING
 SPACES. TO ACCURATELY DEPICT THE FUNCTION OF THE TANDEM
 PARKING SPACES, THE WHEEL STOPS SHOULD BE REMOVED FROM
 THE OUTER STALL OF THE TANDEM PARKING. ALSO, PLANS MUST
 ALSO SHOW WHICH TANDEM SPACES ARE RESERVED FOR
 RESIDENTIAL AND WHICH ARE RESERVED FOR VALET (PER
 JUSTIFICATION STATEMENT).
  
 13.) A NOTE CLEARLY STATING THAT THE TANDEM PARKING
 SPACES WILL BE CLEARLY MARKED AND RESERVED FOR
 VALET/RESIDENTIAL SHALL BE PROVIDED IN THE PLANS.
  
  
 ARCHITECTURAL COMMENTS:
  
 1.) BUILDING HEIGHT INFORMATION INCOMPLETE IN THE
 ELEVATIONS. PLEASE PROVIDE MEASUREMENTS IN ACCORDANCE
 AND CONSISTENT WITH SEC. 94-145 (GENERAL COMMERCIAL
 DISTRICT), SEC. 94-306 (HEIGHT EXCEPTIONS) AND SEC.
 94-611 (HEIGHT OF STRUCTURE).
  
 2.) PLEASE ADDRESS THE FOLLOWING IN THE FLOOR PLANS: A)
 PROVIDE A LEGEND THAT IDENTIFIES WHAT THE COLOR
 COORDINATION MEANS. B) NOT ALL SPACES IN THE FLOOR PLAN
 SHEETS HAVE BEEN LABELED. THIS IS CRITICAL TO DETERMINE
 IF THE SPACES SHOULD/SHOULD NOT BE INCLUDED IN THE FAR
 CALCULATIONS. C) NOTATE NON AIR-CONDITIONED SPACES. IT
 IS IMPORTANT IN VERIFYING WHETHER OR NOT SPACES SHOULD
 BE INCLUDED IN THE FAR CALCULATIONS.
  
 3.) IN THE FAR BUILDING AREA TABLE (SHEET A0.03), WHAT
 ARE THE NOTATIONS IN THE PARENTHESIS?
  
 4.) HOW MANY BEDROOMS ARE PROVIDED IN THE GROUND LEVEL
 FLATS? THE INFORMATION SHOULD BE NOTATED IN THE PLANS.
  
  
 LIGHTING/PHOTOMETRIC COMMENTS:
  
 1.) NO LIGHTING/PHOTOMETRIC PLAN/INFORMATION PROVIDED
 WITH THE APPLICATION SUBMITTAL. PER ZLDR
 S.94-207(D)(8), ANY SOURCE OF ILLUMINATION LOCATED WITH
 A CPD SHALL NOT EXCEED ONE FOOTCANDLE AT OR BEYOND THE
 BOUNDARIES OF SUCH DEVELOPMENT. PLEASE PROVIDE
 INFORMATION AND A PHOTOMETRIC PLAN TO DEMONSTRATE
 COMPLIANCE; SETBACK DIMENSIONS FROM POLE FIXTURE(S) (IF
 APPLICABLE) TO THE PROPERTY LINE(S) SHALL ALSO BE
 PROVIDED. PHOTOMETRIC SPILLOVER BEYOND THE PROPERTY
 LINE(S) IS ALSO REQUIRED TO SHOW COMPLIANCE.
  
 2.) PROVIDE THE FOLLOWING NOTE IN THE PLANS FOR
 CONSISTENCY WITH THE ZLDRS FOR EXTERIOR LIGHTING: ALL
 OUTDOOR LIGHTING SHALL BE SHIELDED TO REDUCE GLARE AND
 SHALL BE ARRANGED TO REFLECT LIGHT, OR GLARE AWAY FROM
 ALL ADJACENT RESIDENTIAL DISTRICTS, ADJACENT
 RESIDENCES, OR PUBLIC THOROUGHFARES.
  
  
 SIGNAGE COMMENTS:
  
 1.) THERE IS A CONFLICT WITH THE SIGNAGE INFORMATION
 PRESENTED FOR THE PROJECT. THE JUSTIFICATION STATEMENT
 INCLUDES A WAIVER TO SIGNAGE (BUT NO SPECIFIC DETAILS);
 HOWEVER, THE PLAN SHEETS STATE: "ALL PROPOSED SIGANGE
 SHALL COMPLY WITH THE SIGNAGE REGULATIONS OF THE
 UNDERLYING ZONING DISTRICT." PLEASE ADDRESS FOR
 CONSISTENCY. THE APPLICATION MUST CLEARLY STATE WHAT IS
 THE WAIVER TO THE SIGN CODE REQUIREMENTS, MUST INCLUDE
 SIGNAGE PROPOSAL FOR THE PROJECT (SIGN PROGRAM,
 INCLUDING DIMENSIONS, ETC.), JUSTIFICATION, MITIGATION
 MEASURES (IF APPLICABLE) AND BENEFIT TO THE COMMUNITY
 IF A WAIVER IS BEING SOUGHT FOR SIGNAGE.
  
  
 INSTRUCTIONS FOR RESUBMITTAL:
  
 * PLEASE PROVIDE RESPONSES TO REVIEW COMMENTS IN
 WRITTEN FORMAT.
  
 * WHEN RESUBMITTING, PLEASE PROVIDE A MINIMUM OF FOUR
 (4) PAPER COPIES AND ONE (1) SET IN 11 INCHES X 17
 INCHES, AND AN ELECTRONIC COPY OF ALL PLANS AND
 DOCUMENTS. THREE (3) HARD COPY SETS SHALL BE PROVIDED
 IN FULL COLOR.
  
 * ANY CHANGES ON THE RESUBMITTED PLANS MAY RESULT IN
 ADDITIONAL COMMENTS.
  
 * PLEASE NOTE THAT YOU WILL BE PERMITTED ONE (1)
 RESUBMITTAL AT NO ADDITIONAL COST. IF PREVIOUSLY-ISSUED
 COMMENTS CONTINUE TO NOT BE SUFFICIENTLY ADDRESSED, THE
 APPLICANT WILL BE ASSESSED A RESUBMITTAL FEE. SUCH FEE
 WILL BE 20 PERCENT OF THE ORIGINAL APPLICATION FEE
 ($600).
  
 * CONTACT LINDA LOUIE @ (5661) 822-1458 IF THERE ARE
 QUESTIONS.
  
  
 NOTES:
  
 * DEDICATION, RESERVATION OR IMPROVEMENT OF PROPERTY
 FOR PUBLIC RIGHTS-OF-WAY, STREETS, SCHOOLS, PARKS, MASS
 TRANSIT FACILITIES OR OTHER PUBLIC FACILITIES MAY BE
 REQUIRED AS A CONDITION OR REQUIREMENT OF THE PLANNED
 DEVELOPMENT. [ZLDR S.94-207(B)(3)]
  
 * ALL UTILITIES, INCLUDING TELEPHONE, CABLE TELEVISION
 AND ELECTRICAL SERVICE SYSTEMS, SHALL BE INSTALLED
 UNDERGROUND. [ZLDR S.94-207(B)(5)]
  
 * OUTDOOR STORAGE FACILITIES ARE PROHIBITED. [ZLDR
 S.94-207(D)(9)]
  
 * DEVELOPMENT SHALL PROVIDE FOR ADEQUATE DRAINAGE AND
 STORMWATER
  

  Print