Plan Review Details - Project Z22080012
Plan Review Stops For Project Z22080012
Review Stop AIPP ART IN PUBLIC PLACES
Rev No 2 Status P Date 10-20-2022 Cont ID  
Sent By swelter Date 10-20-2022 Time 17:13 Rev Time 0.00
Received By SWELTER Date 11-22-2022 Time 10:52 Sent To  
Notes
2023-02-02 13:50:40 
 MISSING ART ASSESSMENT APPLICATION 3.13.23
 ARTIST ALEXANDRE ARRECHEA SELECTED BY DEVELOPERS OF
 SOLESTE PRESENTED HIS PUBLIC ART CONCEPTS FOR THE
 DEVELOPMENT SITE. COMMITTEE NOTED THAT THE FINAL
 PROPOSAL MET THE CRITERIA WITHIN THE CODE SECTION
 78-125.
 A. ARTIST???S SIGNATURE ORANGE INTERNATIONAL COLOR
 B. ABSTRACT AND HIGHLY VISIBLE
 C. DYNAMIC
 D. ???SENSE/FEEL THE MUSIC COMING FROM THE IMAGE
 E. REQUESTED IMAGES THAT DISPLAYED THE VIEWER
 EXPERIENCE FORM VARIOUS ANGLES
  
 F. MET LOCATION REQUIREMENT
 G. MET ARTIST AND ART REQUIREMENT
 H. DISTINCT ART FROM ANY ZONING AND LAND REGULATION
 REQUIREMENTS
 I. MUST PRESENT FOR FORMAL REVIEW AND RECOMMENDATION TO
 CITY COMMISSION ??? DATE TBD.
  
 SITE PLAN APPROVAL FOR IDENTIFIED AREA FOR THE
 INCLUSION OF PUBLIC ART DOES NOT INCLUDE APPROVAL OF
 ARTIST OR ARTWORK.
 THE MEDIUM OF ART ON THE PROPOSED SITE BY A QUALIFIED
 ARTIST MUST BE APPROPRIATE TO THE SITE IN MEDIUM,
 SCALE, AND MATERIALS.
 ARTIST MUST BE IDENTIFIED AND MEET THE QUALIFICATIONS
 IN SECTION 78-122 NO LATER THAN BUILDING PERMIT
 SUBMITTAL TO SYBILLE WELTER AT [email protected]
  

Review Stop AIPP ART IN PUBLIC PLACES
Rev No 1 Status F Date 08-25-2022 Cont ID  
Sent By scwelter Date 08-25-2022 Time 15:54 Rev Time 0.00
Received By rcaranci Date 08-25-2022 Time 16:04 Sent To  
Notes
2022-08-25 16:03:57PUBLIC ART REQUIREMENT:
  
 TOTAL CONSTRUCTION COSTS OVER $500,000
 SUBJECT TO THE PUBLIC ART REQUIREMENT AS PER CITY
 ORDINANCE.
  
 ALL PRIVATE DEVELOPMENT PROJECTS, INCLUDING NEW
 CONSTRUCTION, OR THE RENOVATION OR IMPROVEMENT OF AN
 EXISTING BUILDING, WHERE TOTAL CONSTRUCTION COSTS ARE
 EQUAL TO OR GREATER THAN $500,000 ARE SUBJECT TO THE
 PUBLIC ART REQUIREMENT.
  
 OPTION 1: INSTALL ARTWORK ON THE DEVELOPMENT SITE
 VALUED IN AN AMOUNT NOT LESS THAN ONE PERCENT OF THE
 TOTAL CONSTRUCTION COSTS.
 FOR SITE PLAN APPROVAL PUBLIC ART NEEDS TO BE
 IDENTIFIED ON THE SITE PLAN.
  
 OPTION 2: CONTRIBUTE AN AMOUNT EQUAL TO 75 PERCENT OF
 ONE PERCENT OF THE TOTAL CONSTRUCTION COSTS FOR DEPOSIT
 TO THE PUBLIC ART ACCOUNT.
  
 FOR EITHER OPTION A COMPLETED PUBLIC ART ASSESSMENT
 APPLICATION ALONG WITH EITHER THE ESCROW OF THE 1% OR
 IF CHOSEN OPTION 2 CONTRIBUTION INTO THE PUBLIC ART
 FUND IS REQUIRED AT TIME OF BUILDING PERMIT SUBMITTAL.
  
 CONTACT SYBILLE WELTER, ADMINISTRATOR OF PUBLIC ART &
 CULTURE AT [email protected] WITH FURTHER QUESTIONS.
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 03-09-2023 Cont ID  
Sent By rbrown Date 03-09-2023 Time 19:35 Rev Time 0.00
Received By rbrown Date 03-09-2023 Time 19:35 Sent To  
Notes
2023-03-09 19:36:09DEVELOPMENT SERVICES DEPARTMENT, BUILDING DIVISION,
 COMMENTS:
  
 1. THIS REVIEW IS A CURSORY REVIEW AS IT RELATES TO THE
 SITE. IT IS NOT A REVIEW FOR FULL COMPLIANCE WITH
 FLORIDA BUILDING CODE. THE FOLLOWING COMMENTS ARE TO BE
 ADDRESSED FOR THE BUILDING PERMIT APPLICATION.
  
 2. ELECTRIC VEHICLE CHARGING STATION. IF ELECTRIC
 VEHICLE (EV) CHARGING STATIONS ARE PROVIDED AT LEAST 1
 IN 25 MUST COMPLY WITH ACCESSIBLE PARKING SPACE
 REQUIREMENTS.
  
 3. BUILDING SIZE. WHEN SUBMITTED FOR BUILDING PERMIT,
 THE PLANS SHALL SHOW THAT THE TYPE OF CONSTRUCTION FOR
 THE BUILDINGS WILL BE IN ACCORDANCE WITH THE HEIGHT,
 AREA AND OCCUPANCY LIMITATIONS IN CHAPTER 5 OF THE
 FLORIDA BUILDING CODE.
  
 4. BUILDING LOCATION RELATIVE TO THE PROPERTY LINE AND
 OTHER STRUCTURES. WHEN SUBMITTED FOR BUILDING PERMIT,
 COMPLIANCE WITH ALL BUILDING SEPARATION, PERCENTAGE OF
 OPENINGS AND OPENING PROTECTIVE REQUIREMENTS OF
 CHAPTERS 6 AND 7 OF THE FLORIDA BUILDING CODE SHALL BE
 VERIFIED.
  
 5. ENCLOSED PARKING GARAGES. IF THE PARKING GARAGE DOES
 NOT HAVE WALL OPENINGS, OR SUFFICIENT WALL OPENINGS TO
 MEET THE DEFINITION OF AN OPEN PARKING GARAGE, IT WILL
 BE CONSIDERED AN ENCLOSED PARKING GARAGE AND MUST HAVE
 EXHAUST SYSTEMS. THE EXHAUST SYSTEMS SHALL BE DESIGNED
 TO MINIMIZE NOISE LEVELS USING INLINE FAN SILENCERS OR
 OTHER APPROVED METHODS.
  
 6. SEPARATE PERMITS REQUIRED. ALL APPLICABLE PERMITS
 AND SUB-PERMITS MUST BE OBTAINED BEFORE COMMENCING THE
 WORK. SEPARATE PERMITS, PLANS AND FEES, ARE REQUIRED
 FOR SIGNS, SWIMMING POOLS AND SPAS, GAS SYSTEMS,
 GENERATORS, FIRE ALARM SYSTEMS, FIRE SPRINKLER AND
 OTHER FIRE SUPPRESSION SYSTEMS, GREASE INTERCEPTORS,
 SITE LIGHTING, SITE LANDSCAPE, SITE IRRIGATION, ETC.
  
 7. CONTRACTOR VEHICLE PARKING. PROPERTY OWNER AND
 CONTRACTOR SHALL MAKE ARRANGEMENTS FOR PARKING OF
 CONTRACTOR VEHICLES TO MINIMIZE THE IMPACT ON ALL
 NEIGHBORING PROPERTIES.
  
 8. PROTECTION OF NEIGHBORING PROPERTY. PROPERTY OWNER
 AND CONTRACTOR SHALL PROTECT ALL NEIGHBORING PROPERTY,
 INCLUDING VEHICLES, FROM DAMAGE OR DIRT CAUSED BY THE
 CONSTRUCTION, AND SHALL NOTIFY THE OCCUPANTS OF
 NEIGHBORING PROPERTIES ABOUT ALL STAGES OF CONSTRUCTION
 THAT MAY AFFECT THE USE OF THEIR PROPERTY.
  
 9. BUILDING ADDRESS. EACH SEPARATE BUILDING, AND UNIT
 WITH AN INDEPENDENT ENTRANCE FROM THE STREET, SHALL
 HAVE A SEPARATE ADDRESS ASSIGNED BASED ON THE LOCATION
 OF THE BUILDING ENTRANCE. FOR STREET ADDRESSING,
 CONTACT CAROLINE PUELL, ADDRESSING COORDINATOR, AT
 (561) 805 6659, OR BY EMAIL: [email protected]
  
 ROBERT BROWN
 BUILDING OFFICIAL
 TEL: 561 805 6652
 EMAIL: [email protected]
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 02-22-2023 Cont ID  
Sent By rbrown Date 02-22-2023 Time 19:26 Rev Time 0.00
Received By rbrown Date 02-22-2023 Time 19:26 Sent To  
Notes
2023-02-22 19:30:01DEVELOPMENT SERVICES DEPARTMENT, BUILDING DIVISION,
 COMMENTS:
  
 1. THIS REVIEW IS A CURSORY REVIEW AS IT RELATES TO THE
 SITE. IT IS NOT A REVIEW FOR FULL COMPLIANCE WITH
 FLORIDA BUILDING CODE. THE FOLLOWING COMMENTS ARE TO BE
 ADDRESSED FOR THE BUILDING PERMIT APPLICATION.
  
 2. ACCESSIBLE ENTRANCES. THE ACCESSIBILITY RAMPS HAVE
 BEEN REMOVED FROM THE 4TH STREET ENTRANCES TO THE MAIN
 LOBBY AND THE SOUTH LOBBY. SHOW AT LEAST ONE ACCESSIBLE
 ROUTE, COMPLYING WITH SECTIONS 206.2 AND 402.2 OF
 FLORIDA ACCESSIBILITY CODE, CONNECTING ACCESSIBLE
 BUILDING OR FACILITY ENTRANCES WITH ALL ACCESSIBLE
 SPACES AND ELEMENTS WITHIN THE BUILDING OR FACILITY
  
 3. ELECTRIC VEHICLE CHARGING STATION. IF ELECTRIC
 VEHICLE (EV) CHARGING STATIONS ARE PROVIDED AT LEAST 1
 IN 25 MUST COMPLY WITH ACCESSIBLE PARKING SPACE
 REQUIREMENTS.
  
 4. BUILDING SIZE. WHEN SUBMITTED FOR BUILDING PERMIT,
 THE PLANS SHALL SHOW THAT THE TYPE OF CONSTRUCTION FOR
 THE BUILDINGS WILL BE IN ACCORDANCE WITH THE HEIGHT,
 AREA AND OCCUPANCY LIMITATIONS IN CHAPTER 5 OF THE
 FLORIDA BUILDING CODE.
  
 5. BUILDING LOCATION RELATIVE TO THE PROPERTY LINE AND
 OTHER STRUCTURES. WHEN SUBMITTED FOR BUILDING PERMIT,
 COMPLIANCE WITH ALL BUILDING SEPARATION, PERCENTAGE OF
 OPENINGS AND OPENING PROTECTIVE REQUIREMENTS OF
 CHAPTERS 6 AND 7 OF THE FLORIDA BUILDING CODE SHALL BE
 VERIFIED.
  
 6. ENCLOSED PARKING GARAGES. IF THE PARKING GARAGE DOES
 NOT HAVE WALL OPENINGS, OR SUFFICIENT WALL OPENINGS TO
 MEET THE DEFINITION OF AN OPEN PARKING GARAGE, IT WILL
 BE CONSIDERED AN ENCLOSED PARKING GARAGE AND MUST HAVE
 EXHAUST SYSTEMS. THE EXHAUST SYSTEMS SHALL BE DESIGNED
 TO MINIMIZE NOISE LEVELS USING INLINE FAN SILENCERS OR
 OTHER APPROVED METHODS.
  
 7. SEPARATE PERMITS REQUIRED. ALL APPLICABLE PERMITS
 AND SUB-PERMITS MUST BE OBTAINED BEFORE COMMENCING THE
 WORK. SEPARATE PERMITS, PLANS AND FEES, ARE REQUIRED
 FOR SIGNS, SWIMMING POOLS AND SPAS, GAS SYSTEMS,
 GENERATORS, FIRE ALARM SYSTEMS, FIRE SPRINKLER AND
 OTHER FIRE SUPPRESSION SYSTEMS, GREASE INTERCEPTORS,
 SITE LIGHTING, SITE LANDSCAPE, SITE IRRIGATION, ETC.
  
 8. CONTRACTOR VEHICLE PARKING. PROPERTY OWNER AND
 CONTRACTOR SHALL MAKE ARRANGEMENTS FOR PARKING OF
 CONTRACTOR VEHICLES TO MINIMIZE THE IMPACT ON ALL
 NEIGHBORING PROPERTIES.
  
 9. PROTECTION OF NEIGHBORING PROPERTY. PROPERTY OWNER
 AND CONTRACTOR SHALL PROTECT ALL NEIGHBORING PROPERTY,
 INCLUDING VEHICLES, FROM DAMAGE OR DIRT CAUSED BY THE
 CONSTRUCTION, AND SHALL NOTIFY THE OCCUPANTS OF
 NEIGHBORING PROPERTIES ABOUT ALL STAGES OF CONSTRUCTION
 THAT MAY AFFECT THE USE OF THEIR PROPERTY.
  
 10. BUILDING ADDRESS. EACH SEPARATE BUILDING, AND UNIT
 WITH AN INDEPENDENT ENTRANCE FROM THE STREET, SHALL
 HAVE A SEPARATE ADDRESS ASSIGNED BASED ON THE LOCATION
 OF THE BUILDING ENTRANCE. FOR STREET ADDRESSING,
 CONTACT CAROLINE PUELL, ADDRESSING COORDINATOR, AT
 (561) 805 6659, OR BY EMAIL: [email protected]
  
 ROBERT BROWN
 BUILDING OFFICIAL
 TEL: 561 805 6652
 EMAIL: [email protected]
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 02-01-2023 Cont ID  
Sent By rbrown Date 02-01-2023 Time 09:51 Rev Time 0.00
Received By rbrown Date 02-01-2023 Time 09:46 Sent To  
Notes
2023-02-01 09:51:39DEVELOPMENT SERVICES DEPARTMENT, BUILDING DIVISION,
 COMMENTS:
  
 1. THIS REVIEW IS A CURSORY REVIEW AS IT RELATES TO THE
 SITE. IT IS NOT A REVIEW FOR FULL COMPLIANCE WITH
 FLORIDA BUILDING CODE. THE FOLLOWING COMMENTS ARE TO BE
 ADDRESSED FOR THE BUILDING PERMIT APPLICATION.
  
 2. ELECTRIC VEHICLE CHARGING STATION. IF ELECTRIC
 VEHICLE (EV) CHARGING STATIONS ARE PROVIDED AT LEAST 1
 IN 25 MUST COMPLY WITH ACCESSIBLE PARKING SPACE
 REQUIREMENTS.
  
 3. BUILDING SIZE. WHEN SUBMITTED FOR BUILDING PERMIT,
 THE PLANS SHALL SHOW THAT THE TYPE OF CONSTRUCTION FOR
 THE BUILDINGS WILL BE IN ACCORDANCE WITH THE HEIGHT,
 AREA AND OCCUPANCY LIMITATIONS IN CHAPTER 5 OF THE
 FLORIDA BUILDING CODE.
  
 4. BUILDING LOCATION RELATIVE TO THE PROPERTY LINE AND
 OTHER STRUCTURES. WHEN SUBMITTED FOR BUILDING PERMIT,
 COMPLIANCE WITH ALL BUILDING SEPARATION, PERCENTAGE OF
 OPENINGS AND OPENING PROTECTIVE REQUIREMENTS OF
 CHAPTERS 6 AND 7 OF THE FLORIDA BUILDING CODE SHALL BE
 VERIFIED.
  
 5. ENCLOSED PARKING GARAGES. IF THE PARKING GARAGE DOES
 NOT HAVE WALL OPENINGS, OR SUFFICIENT WALL OPENINGS TO
 MEET THE DEFINITION OF AN OPEN PARKING GARAGE, IT WILL
 BE CONSIDERED AN ENCLOSED PARKING GARAGE AND MUST HAVE
 EXHAUST SYSTEMS. THE EXHAUST SYSTEMS SHALL BE DESIGNED
 TO MINIMIZE NOISE LEVELS USING INLINE FAN SILENCERS OR
 OTHER APPROVED METHODS.
  
 6. SEPARATE PERMITS REQUIRED. ALL APPLICABLE PERMITS
 AND SUB-PERMITS MUST BE OBTAINED BEFORE COMMENCING THE
 WORK. SEPARATE PERMITS, PLANS AND FEES, ARE REQUIRED
 FOR SIGNS, SWIMMING POOLS AND SPAS, GAS SYSTEMS,
 GENERATORS, FIRE ALARM SYSTEMS, FIRE SPRINKLER AND
 OTHER FIRE SUPPRESSION SYSTEMS, GREASE INTERCEPTORS,
 SITE LIGHTING, SITE LANDSCAPE, SITE IRRIGATION, ETC.
  
 7. CONTRACTOR VEHICLE PARKING. PROPERTY OWNER AND
 CONTRACTOR SHALL MAKE ARRANGEMENTS FOR PARKING OF
 CONTRACTOR VEHICLES TO MINIMIZE THE IMPACT ON ALL
 NEIGHBORING PROPERTIES.
  
 8. PROTECTION OF NEIGHBORING PROPERTY. PROPERTY OWNER
 AND CONTRACTOR SHALL PROTECT ALL NEIGHBORING PROPERTY,
 INCLUDING VEHICLES, FROM DAMAGE OR DIRT CAUSED BY THE
 CONSTRUCTION, AND SHALL NOTIFY THE OCCUPANTS OF
 NEIGHBORING PROPERTIES ABOUT ALL STAGES OF CONSTRUCTION
 THAT MAY AFFECT THE USE OF THEIR PROPERTY.
  
 9. BUILDING ADDRESS. EACH SEPARATE BUILDING, AND UNIT
 WITH AN INDEPENDENT ENTRANCE FROM THE STREET, SHALL
 HAVE A SEPARATE ADDRESS ASSIGNED BASED ON THE LOCATION
 OF THE BUILDING ENTRANCE. FOR STREET ADDRESSING,
 CONTACT CAROLINE PUELL, ADDRESSING COORDINATOR, AT
 (561) 805 6659, OR BY EMAIL: [email protected]
  
 ROBERT BROWN
 BUILDING OFFICIAL
 TEL: 561 805 6652
 EMAIL: [email protected]
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 09-07-2022 Cont ID  
Sent By rbrown Date 09-07-2022 Time 12:17 Rev Time 0.00
Received By rbrown Date 09-07-2022 Time 12:17 Sent To  
Notes
2022-09-07 12:47:42DEVELOPMENT SERVICES DEPARTMENT, BUILDING DIVISION,
 COMMENTS:
  
 1. THIS REVIEW IS A CURSORY REVIEW AS IT RELATES TO THE
 SITE. IT IS NOT A REVIEW FOR FULL COMPLIANCE WITH
 FLORIDA BUILDING CODE. THE FOLLOWING COMMENTS ARE TO BE
 ADDRESSED FOR THE BUILDING PERMIT APPLICATION.
  
 2. EXIT DISCHARGE FROM STAIR. PLAN SHEET A2.1, GROUND
 FLOOR PLAN, SHOWS THE SOUTH STAIR IN THE SOUTH TOWER
 WITH NO WAY TO GET OUT OF THE STAIR AND EXIT THE
 BUILDING WITHOUT PASSING ALONG THE PARKING GARAGE DRIVE
 ACCESS ROAD OR PASSING THROUGH THE LOADING BAY. PER
 SECTION 1028.1 OF FLORIDA BUILDING CODE THE EXIT SHALL
 DISCHARGE DIRECTLY TO THE EXTERIOR OF THE BUILDING.
  
 3. EXIT FROM SOUTH TOWER AMENITIES AREA. PLAN SHEET
 A2.2, SECOND FLOOR PLAN, SHOWS THAT SOUTH TOWER
 AMENITIES AREA WITHOUT 2 SEPARATE MEANS OF EGRESS. PER
 SECTIONS 1006.2.1 AND 1007.1.1 OF FLORIDA BUILDING CODE
 2 MEANS OF EGRESS ARE REQUIRED AND THEY MUST BE
 SEPARATED BY 1/3 OF THE DIAGAONAL DIMENSION OF THE
 ROOM.
  
 4. VAN ACCESSIBLE PARKING SPACES. THE PLANS DO NOT SHOW
 A VAN ACCESSIBLE PARKING SPACE. PER SECTION 208.2.4 OF
 FLORIDA ACCESSIBILITY CODE, ONE IN EVERY SIX REQUIRED
 ACCESSIBLE SPACES (AT LEAST ONE) IN A PARKING
 STRUCTURE, SHALL BE ?VAN ACCESSIBLE? AND DESIGNED IN
 ACCORDANCE WITH SECTION OF 502 OF FLORIDA ACCESSIBILITY
 CODE (VERTICAL CLEARANCE NOT LESS THAN 98 INCHES AT
 SPACE AND VEHICULAR ACCESS ROUTE)
  
 5. ELECTRIC VEHICLE CHARGING STATION. IF ELECTRIC
 VEHICLE (EV) CHARGING STATIONS ARE PROVIDED AT LEAST 1
 IN 25 MUST COMPLY WITH ACCESSIBLE PARKING SPACE
 REQUIREMENTS.
  
 6. BUILDING SIZE. WHEN SUBMITTED FOR BUILDING PERMIT,
 THE PLANS SHALL SHOW THAT THE TYPE OF CONSTRUCTION FOR
 THE BUILDINGS WILL BE IN ACCORDANCE WITH THE HEIGHT,
 AREA AND OCCUPANCY LIMITATIONS IN CHAPTER 5 OF THE
 FLORIDA BUILDING CODE.
  
 7. BUILDING LOCATION RELATIVE TO THE PROPERTY LINE AND
 OTHER STRUCTURES. WHEN SUBMITTED FOR BUILDING PERMIT,
 COMPLIANCE WITH ALL BUILDING SEPARATION, PERCENTAGE OF
 OPENINGS AND OPENING PROTECTIVE REQUIREMENTS OF
 CHAPTERS 6 AND 7 OF THE FLORIDA BUILDING CODE SHALL BE
 VERIFIED.
  
 8. ENCLOSED PARKING GARAGES. IF THE PARKING GARAGE DOES
 NOT HAVE WALL OPENINGS, OR SUFFICIENT WALL OPENINGS TO
 MEET THE DEFINITION OF AN OPEN PARKING GARAGE, IT WILL
 BE CONSIDERED AN ENCLOSED PARKING GARAGE AND MUST HAVE
 EXHAUST SYSTEMS. THE EXHAUST SYSTEMS SHALL BE DESIGNED
 TO MINIMIZE NOISE LEVELS USING INLINE FAN SILENCERS OR
 OTHER APPROVED METHODS.
  
 9. SEPARATE PERMITS REQUIRED. ALL APPLICABLE PERMITS
 AND SUB-PERMITS MUST BE OBTAINED BEFORE COMMENCING THE
 WORK. SEPARATE PERMITS, PLANS AND FEES, ARE REQUIRED
 FOR SIGNS, SWIMMING POOLS AND SPAS, GAS SYSTEMS,
 GENERATORS, FIRE ALARM SYSTEMS, FIRE SPRINKLER AND
 OTHER FIRE SUPPRESSION SYSTEMS, GREASE INTERCEPTORS,
 SITE LIGHTING, SITE LANDSCAPE, SITE IRRIGATION, ETC.
  
 10. CONTRACTOR VEHICLE PARKING. PROPERTY OWNER AND
 CONTRACTOR SHALL MAKE ARRANGEMENTS FOR PARKING OF
 CONTRACTOR VEHICLES TO MINIMIZE THE IMPACT ON ALL
 NEIGHBORING PROPERTIES.
  
 11. PROTECTION OF NEIGHBORING PROPERTY. PROPERTY OWNER
 AND CONTRACTOR SHALL PROTECT ALL NEIGHBORING PROPERTY,
 INCLUDING VEHICLES, FROM DAMAGE OR DIRT CAUSED BY THE
 CONSTRUCTION, AND SHALL NOTIFY THE OCCUPANTS OF
 NEIGHBORING PROPERTIES ABOUT ALL STAGES OF CONSTRUCTION
 THAT MAY AFFECT THE USE OF THEIR PROPERTY.
  
 12. BUILDING ADDRESS. EACH SEPARATE BUILDING, AND UNIT
 WITH AN INDEPENDENT ENTRANCE FROM THE STREET, SHALL
 HAVE A SEPARATE ADDRESS ASSIGNED BASED ON THE LOCATION
 OF THE BUILDING ENTRANCE. FOR STREET ADDRESSING,
 CONTACT CAROLINE PUELL, ADDRESSING COORDINATOR, AT
 (561) 805 6659, OR BY EMAIL: [email protected]
  
 13. ART IN PUBLIC PLACES. THIS PROJECT WILL BE SUBJECT
 TO ART LIFE ASSESSMENT UNDER THE CITY OF WEST PALM
 BEACH ART IN PUBLIC PLACES (AIPP) PROGRAM. FOR ADVICE
 ON THE PROVISION OF PUBLIC ARTWORK IN LIEU OF THE AIPP
 ASSESSMENT, CONTACT SYBILLE WELTER, ART IN PUBLIC
 PLACES COORDINATOR, AT (561) 822-1521, OR BY EMAIL:
 [email protected]
  
 ROBERT BROWN
 BUILDING OFFICIAL
 TEL: 561 805 6652
 EMAIL: [email protected]
  

Review Stop ENG - PPRC ENGINEERING - PPRC
Rev No 3 Status P Date 02-16-2023 Cont ID  
Sent By rrossano Date 02-16-2023 Time   Rev Time 0.00
Received By rrossano Date 02-16-2023 Time   Sent To  
Notes
***NONE***

Review Stop ENG - PPRC ENGINEERING - PPRC
Rev No 2 Status F Date 10-20-2022 Cont ID  
Sent By rrossano Date 10-20-2022 Time   Rev Time 0.00
Received By rrossano Date 10-20-2022 Time   Sent To  
Notes
2022-10-20 12:59:33PROVISION OF CCTV VIDEO OF EXISTING SANITARY SEWER AND
 STORMWATER INFRASTRUCTURE ALONG ENTIRE PROJECT FRONTAGE
 IS A CONDITION OF SITE PLAN APPROVAL.
  

Review Stop ENG - PPRC ENGINEERING - PPRC
Rev No 1 Status F Date 08-23-2022 Cont ID  
Sent By rrossano Date 08-23-2022 Time   Rev Time 0.00
Received By rrossano Date 08-23-2022 Time   Sent To  
Notes
2022-08-23 13:00:15COMMENTS FROM RICK ROSSANO, SR. PROJECT COORDINATOR,
 ENGINEERING SERVICES AT 561-494-1098 [email protected]
 GENERAL:
 O PLEASE RESPOND TO ALL COMMENTS IN WRITING, AND
 INCLUDE PROJECT NAME, ADDRESS AND PERMIT NUMBER
 (Z-XXXXXXXX).
 O THE CITY OF WEST PALM BEACH HAS A NUMBER OF
 REGULATIONS AND PERMIT REQUIREMENTS WHICH DIRECTLY
 AFFECT THE DEVELOPMENT AND INSTALLATION OF WATER AND
 WASTEWATER UTILITIES WITHIN THE CITY. PLEASE SEE
 DEVELOPMENT PERMIT SUBMITTAL REQUIREMENTS AT THE LINK
 BELOW:
 A. HTTP://WPB.ORG/CMSPAGES/GETAMAZONFILE.ASPX?PATH=~\WP
 B_WEBSITE\MEDIA\ENGINEERING\DEVELOPMENT-APPLICATION-FUL
 L-PACKAGE_2016.PDF&HASH=7BD4DD7EB6115181D8C5977BCC02A97
 B1960045731D3658206F27451722716EF
 B. THIS AND OTHER RELATED ENGINEERING DOCUMENTS CAN BE
 FOUND HERE:
 HTTP://WPB.ORG/DEPARTMENTS/ENGINEERING-PUBLIC-WORKS/FOR
 MS,-PERMITS-APPLICATIONS
 C. ALSO SEE: CODE OF ORDINANCES, CITY OF WEST PALM
 BEACH, FLORIDA, CODIFIED THROUGH ORD. NO. 4183-08,
 ADOPTED SEPT. 22, 2008. (SUPPLEMENT NO. 18)
 CHAPTER 90 UTILITIES, ARTICLE I. IN GENERAL,
 SEC. 90-7. POLICY REGARDING EXTENSION OF WATER OR SEWER
 SERVICE FACILITIES OF THE CITY.
 THE WATER AND WASTEWATER SERVICE AGREEMENTS AND THE
 CONSTRUCTION PERMITS ADDRESS RESERVATION OF CAPACITY
 BASED ON USAGE, METER SIZE AND FEES, DESIGN STANDARDS,
 BACKFLOW PREVENTION, FIRE SERVICE AND IRRIGATION.
 O AS OF DECEMBER 20, 2015, THE CITY OF WEST PALM BEACH
 CROSS-CONNECTION CONTROL MANUAL HAS BEEN REVISED,
 STATING "ALL BACKFLOW DEVICES MUST BE LEAD-FREE". FOR
 MORE INFORMATION, REFER TO THE LINK BELOW:
 A. HTTP://WPB.ORG/DEPARTMENTS/PUBLIC-UTILITIES/FORMS-PU
 BLICATIONS/BACKFLOW-CROSS-CONNECTION- CONTROL-MANUAL
 O PLEASE SUBMIT A FORMAL AS-BUILT REQUEST FOR ALL CITY
 OF WEST PALM BEACH-OWNED UTILITIES WITHIN THE PUBLIC
 RIGHT OF WAY FOR THE ENTIRE EXTENT OF THE LIMITS OF
 YOUR PROJECT. IDENTIFY TYPE OF UTILITY, LOCATION, PIPE
 MATERIAL, AGE AND SIZE. PLEASE CONTACT JANICE TARBILL
 IN THE WPB ENGINEERING SERVICES DEPARTMENT AT
 [email protected] OR 561-494-1079 FOR FURTHER
 ASSISTANCE. NOTE THAT FIELD RECORDS ARE FOR INFORMATION
 ONLY. FIELD VERIFY UTILITY LOCATIONS USING FIELD
 SURVEY, POT-HOLING, SOFT DIGS ETC.
 O PROVIDE EXISTING AND PROPOSED PERVIOUS AND IMPERVIOUS
 DATA.
  
 BACKFLOW ASSEMBLY AND METERS:
 O SHOW AND LABEL ANY EXISTING OR PROPOSED WATER
 SERVICES AND WATER METERS, ALONG WITH WHAT IS HAPPENING
 TO THEM.
 O SHOW EXISTING AND PROPOSED DEDICATED UTILITY
 EASEMENTS TO ALLOW ACCESS FOR CITY PERSONNEL TO
 PROPOSED UTILITY WATER METERS. VERIFY THAT THERE ARE NO
 STRUCTURES WITHIN EASEMENT.
 O PROVIDE ENLARGED VIEW ON PLANS OF PROPOSED LOCATION
 OF WATER METER AND BACKFLOW
 PREVENTION.
 O BACKFLOWS SHALL BE INSTALLED ON PRIVATE PROPERTY
 OUTSIDE OF EASEMENTS AND RIGHTS OF WAY. DOMESTIC WATER
 METERS SHALL BE INSTALLED IMMEDIATELY ADJACENT TO
 PROPERTY LINE. 3 INCH AND LARGER WATER METERS SHALL BE
 INSTALLED ABOVE-GROUND ONLY.
 O CALLOUT DOMESTIC BACKFLOW PREVENTER AS RPPA (MAKE
 NOTE USC APPROVED) AND FIRE BACKFLOW PREVENTER AS DCDA.
  
 WATER/WASTEWATER PLAN:
 O PROVIDE VERTICAL DATUM AND DATUM CONVERSION
 INFORMATION (NAVD 1988 AND NGVD 1929).
 O SHOW PROJECT ADDRESS ON ALL PLAN SHEETS.
 O PROVIDE LEGEND ON ALL PLAN SHEETS TO INCLUDE
 STREETLIGHT, SIGN POSTS, TRANSFORMER BOXES ETC.
 O PLANS SHALL SHOW EXISTING AND PROPOSED LOCATIONS AND
 DIMENSIONS OF ALL WATER, STORMWATER, AND SANITARY AND
 SEWER LINES AND CLEANOUTS, INCLUDING STUBS TO EACH
 PROPERTY LINE FOR WATER AND SANITARY SEWERS, THE MAKE
 AND MODEL OF ALL VALVES, POTABLE AND IRRIGATION METERS,
 BACKFLOWS, FIRE HYDRANTS AND FDCS, AND OTHER DEVICES TO
 BE INSTALLED ON THE SYSTEM, CATCH BASINS, CULVERTS,
 DITCHES INCLUDING GRADES, PIPES SIZES, MATERIALS,
 ELEVATIONS, ASSUMPTIONS, CALCULATIONS, INVERT
 ELEVATIONS FOR ALL INLETS AND MANHOLES AND PROFILES OF
 SANITARY SEWER LINES.
 O GATE VALVE BOXES SHALL NOT BE INSTALLED IN CURB OR
 SIDEWALK. ALL AVAILABLE ELEVATION SHALL BE SHOWN ON THE
 PROFILE VIEW.
 O DIRECTION OF FLOW SHALL BE SHOWN ON PLAN VIEW ON PLAN
 VIEW FOR ALL SANITARY AND STORM SEWERS.
 O SHOW SLOPE % ON ALL SANITARY LINES AND CALL OUT
 MATERIAL.
 O PLAN VIEW SHALL SHOW ALL EXISTING AND PROPOSED
 UNDERGROUND UTILITY LAYOUT, INCLUDING FIBER OPTIC,
 ELECTRIC, GAS, AND CABLEVISION & TELECOMMUNICATION
 FACILITIES INCLUDING PIPE SIZE AND MATERIAL LOCATED IN
 THE RIGHT-OF-WAY.
 O PROVIDE PROFILE AND CLEARANCES BETWEEN WATER, SEWER
 AND STORM LINES PER CITY OF WEST PALM BEACH STANDARD
 DETAIL GN-2 SERIES, AT ALL UTILITY CROSSINGS. PLEASE
 INCLUDE FIBER OPTIC, ELECTRIC, GAS, AND CABLEVISION &
 TELECOMMUNICATION FACILITIES INCLUDING PIPE SIZE AND
 MATERIAL LOCATED IN THE RIGHT-OF-WAY.
 O SUBMIT COMPLETED LOS ANALYSIS SUMMARY TABLE DIRECTLY
 TO ENGINEERING (SHEET 33 OF CITY OF WPB DEVELOPMENT
 APPLICATION). PROVIDE CALCULATIONS ON PLANS OF EXISTING
 AND PROPOSED DEMANDS FOR WATER & SEWER (AVERAGE,
 MAXIMUM AND PEAK) AND FIRE FLOW DEMANDS. CALCULATIONS
 SHALL BE PER FAC 64E-6 FOR SEWER AND PER FAC 64-E.008
 FOR WATER.
 O PROVIDE FIRE FLOW TEST DATA.
 O PROVIDE CCTV VIDEO OF EXISTING SANITARY SEWER AND
 STORMWATER INFRASTRUCTURE ALONG ENTIRE PROJECT FRONTAGE
 (CONDITION OF SITE PLAN APPROVAL).
 O CUT AND CAP UTILITIES NOT IN USE AND REMOVE ANY
 ABANDONED UTILITY LINES LARGER THAN 2 INCHES FROM CITY
 ROW.
 O WHEN PROPOSED, WATER MAINS IN CITY RIGHT OF WAY SHALL
 BE MADE OF DUCTILE IRON PIPE (NOT PVC) AND SPECIFY
 PROPOSED LENGTH IN FEET.
 O CHECK TO SEE IF FDEP FORMS FOR PROPOSED SANITARY
 SEWER ARE REQUIRED.
 O PROVIDE CLEANOUTS FOR PROPOSED SANITARY LINE ONSITE
 JUST INSIDE PROPERTY LINE, AT JOINTS AND EVERY 75 FEET.
 O ADD NOTE TO PLANS SPECIFYING CITY?S DOWNSTREAM LIFT
 STATION NUMBER.
 O PROVIDE ONSITE CLEANOUTS NEAR PROPERTY LINE FOR
 PROPOSED SANITARY LATERALS.
 O LABEL WATER LINES AS PRIVATE WHERE APPLICABLE.
 O PLEASE SHOW AND LABEL EXISTING AND PROPOSED GREASE
 TRAPS (IF ANY).
 O PER CITY STANDARDS MAINTAIN MINIMUM DISTANCE BETWEEN
 OUTSIDE DIAMETER OF CITY PIPE AND ROOT BARRIER.
  
 FORMAL ENGINEERING REVIEW:
 O FOR FORMAL ENGINEERING SUBMITTAL, SFWMD ERP AND NPDES
 NOI REQUIREMENTS WILL BE ENFORCED.
 - AN NOI IS REQUIRED FOR PROJECTS THAT:
 - 1) DISTURB ONE OF MORE ACRES OF LAND OR DISTURB LESS
 THAN ON ACRE OF LAND BUT ARE PART OF A COMMON PLAN OF
 DEVELOPMENT OR SALE;
 - 2) DISCHARGE STORMWATER TO SURFACE WATERS OF THE
 STATE OR TO SURFACE WATERS OF THE STATE THROUGH A
 MUNICIPAL SEPARATE STORM SEWER SYSTEM (MS4).
 - THE SFWMD ERP CAN BE OBTAINED THROUGH A 10-2 SELF
 CERTIFICATION THROUGH FDEP OR AN ERP APPLICATION
 THROUGH SFWMD. EITHER WAY, THE DEVELOPER/ENGINEER SHALL
 SUBMIT A COPY OF THE ERP PERMIT OR FDEP ACKNOWLEDGEMENT
 OF THE 10-2 CERTIFICATION.
 O FOR FORMAL ENGINEERING SUBMITTAL, PLEASE PROVIDE
 EASEMENT FOR PLACEMENT OF PROPOSED WATER METERS.
 O FOR FORMAL ENGINEERING SUBMITTAL, PROVIDE PROFILES OF
 WATER AND SEWER AND SHOW ANY CROSSINGS/CONFLICTS.
 O FOR FORMAL ENGINEERING SUBMITTAL, WHEN SUBMITTING
 APPROVED MATERIALS LIST, PLEASE PROVIDE MATERIAL/CUT
 SHEETS FOR ALL PROPOSED BACKFLOW DEVICES SHOWING
 SPECIFIC MODEL NUMBER AND SPECIFYING USC APPROVED
 LEAD-FREE DESIGN.
 O FOR FORMAL ENGINEERING SUBMITTAL, IF SANITARY LINES
 ARE PROPOSED IN ROW PLEASE SHOW ADJACENT SANITARY
 LATERAL LOCATIONS AND SHOW ADDRESSES OF ADJACENT
 PARCELS.
 O FOR FORMAL ENGINEERING SUBMITTAL, IF WATER LINES ARE
 BEING REPLACED IN ROW, SHOW ADJACENT PARCEL ADDRESSES.
 O FOR FORMAL ENGINEERING SUBMITTAL, ADD NOTE TO PROVIDE
 50 FT. PAVEMENT RESTORATION TRANSITION ON EACH SIDE OF
 PROPOSED TRENCH IN CITY MAINTAINED ROADWAY AREAS PER
 CITY OF WPB STANDARD DETAIL GC-8.
 O FOR FORMAL ENGINEERING SUBMITTAL, PLEASE PROVIDE
 CALCULATIONS OF PERVIOUS AND IMPERVIOUS AREAS FOR
 PROPOSED IMPROVED AREAS.
  
 QUESTIONS AND COORDINATION CONTACTS:
 O MARK HURLEY, FIELD CUSTOMER SERVICE SUPERVISOR WITH
 CITY OF WPB PUBLIC UTILITIES, REGARDING PLACEMENT OF
 BACKFLOW DEVICES AND WATER METERS. CONTACT HIM AT
 561-822-2262 OR [email protected]
 O MIKE TECHNOW, PROJECT ENGINEER, PUBLIC UTILITIES
 DEPARTMENT AT 561-494-1047 OR [email protected]
 O TRACY WARD, SR. STORMWATER ENGINEER, ENGINEERING
 SERVICES DEPT. AT 561-494-1120 OR [email protected]
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 08-29-2022 Cont ID  
Sent By pleduc Date 08-29-2022 Time   Rev Time 0.00
Received By pleduc Date 08-29-2022 Time 11:46 Sent To  
Notes
2022-08-29 11:52:05THE FOLLOWING COMMENTS WERE SUBMITTED BY PETER LEDUC,
 FIRE MARSHAL, BUREAU OF FIRE PREVENTION, WEST PALM
 BEACH FIRE DEPARTMENT.
  
 THIS REVIEW CAN ONLY BE CONSIDERED PRELIMINARY AS THE
 DRAWINGS THAT WERE REVIEWED WERE NOT COMPLETE.
 ADDITIONAL COMMENTS CAN BE EXPECTED WHEN FULL DRAWINGS
 ARE SUBMITTED FOR PERMIT.
  
 THE FIRE PREVENTION BUREAU HAS NO OBJECTIONS TO THE
 PROPOSED PROJECT. THE FOLLOWING COMMENTS ARE INTENDED
 TO PROVIDE GUIDANCE FOR BUILDING PLAN SUBMITTAL.
  
 1. CONSTRUCTION, DEMOLITION, AND RENOVATION TO COMPLY
 WITH NFPA 241. EXTRA ATTENTION SHALL BE GIVEN TO THE
 PERMITTING AND LOCATION OF CONSTRUCTION TRAILERS. A
 PERMIT IS REQUIRED FOR ANY CONSTRUCTION TRAILER RELATED
 TO THIS PROJECT. SEPARATION DISTANCES FROM MAIN
 STRUCTURES AS WELL AS OTHER TRAILERS SHALL BE CLOSELY
 MONITORED FOR THE REQUIREMENTS OF FIRE SPRINKLER
 PROTECTION.
  
 2. SITE ACCESS AND EXIT POINTS ARE TO BE CLEARLY
 IDENTIFIED AND MAINTAINED FOR EMERGENCY VEHICLES DURING
 ALL CONSTRUCTION ACTIVITIES.
  
 3. THE BUILDING ADDRESS SHALL BE CLEARLY VISIBLE FROM
 ALL ACCESS ROADWAYS, INCLUDING DURING CONSTRUCTION.
 ADDRESS NUMBERS SHALL CONTRAST WITH THEIR BACKGROUND
 AND SHALL NOT BE LESS THAN SIX (6) INCHES IN HEIGHT
 WITH A ONE (1) INCH STROKE FOR ALL BUILDINGS.
  
 4. DURING CONSTRUCTION, TRASH AND DEBRIS IS TO BE
 REMOVED FROM THE SITE DAILY OR MORE OFTEN TO REDUCE THE
 ACCUMULATION OF POTENTIAL LIFE AND FIRE SAFETY HAZARDS.
  
 5. THE CONSTRUCTION OF THE BUILDING(S) SHALL COMPLY
 WITH THE 7TH EDITION OF THE FLORIDA FIRE PREVENTION
 CODE, INCLUDING NFPA 1 & 101, AND ALL ASSOCIATED FIRE
 CODES.
  
 6. FOR PLAN REVIEW SUBMITTAL, PLEASE INCLUDE THE
 OCCUPANCY TYPE PER THE FLORIDA FIRE PREVENTION CODE.
  
 7. FOR PLAN REVIEW SUBMITTAL, PLEASE ENSURE THAT A FIRE
 LOAD CALCULATION IS INCLUDED, AND THAT ADEQUATE WATER
 SUPPLY IS EXISTING OR WILL BE PROVIDED.
  
 8. ALL EXISTING AND NEW FIRE HYDRANTS PLANNED FOR THIS
 DEVELOPMENT SHALL BE CLEARLY INDICATED AND IDENTIFIED
 ON THE PLAN AND CLOSELY COORDINATED WITH THE BUREAU OF
 FIRE PREVENTION.
  
 THE PROPOSED LOCATION OF THE FIRE HYDRANT AND FDC SHALL
 BE WITHIN 100' OF EACH OTHER AND CLOSELY COORDINATED
 WITH THE BUREAU OF FIRE PREVENTION.
  
 9. PROVIDE FOR A FIRE SPRINKLER AND/OR FIRE ALARM PER
 THE APPLICABLE OCCUPANCY CODE. FOR ANY LIFE SAFETY
 ENGINEERED SYSTEM, I.E FIRE SPRINKLER AND FIRE ALARM,
 ENSURE THEY COMPLY WITH THE REQUIREMENTS OF F.A.C. 61G
 AND SUBMITTED WITH THE MASTER PERMIT.
  
 9A. THE LOCATION OF ANY APPLICABLE DDCV AND FIRE LINE
 LOCATIONS SHALL MEET AND BE INSTALLED PER THE
 REQUIREMENTS OF NFPA 24 AND SHALL BE COORDINATED WITH
 THE OFFICE OF FIRE MARSHAL, THE CITY'S ENGINEERS
 OFFICE, THE LANDSCAPE PLANNER, AND THE CITY'S PLANNING
 AND ZONING OFFICE.
  
 10. COMPLETE LIFE SAFETY PLANS FOR THE OCCUPANCY SHALL
 BE PROVIDED THAT ILLUSTRATE OCCUPANT LOADS, TRAVEL
 DISTANCES, EXIT SEPARATION DISTANCES, COMMON PATHS OF
 TRAVEL, DEAD-END CORRIDORS, EXIT SIGNS, EMERGENCY
 LIGHTING, EXITS LEADING TO A PUBLIC WAY, FIRE
 EXTINGUISHER LOCATIONS, AND ALL FIRE SAFETY FEATURES
 AND EQUIPMENT.
  
 PLEASE REVIEW THE AMENITY DECK OCCUPANCY LOAD TOTAL AND
 ENSURE THAT THERE IS THE APPLICABLE REQUIRED NUMBER OF
 EXITS AND EXIT WIDTH FOR THAT/THOSE AREA(S).
  
 11. IT IS HIGHLY RECOMMENDED (REQUIRED WITH FIRE
 SPRINKLER SYSTEM) THAT A KNOX BOX WITH KEYS FOR ENTRY
 DOOR LOCKS BE PROVIDED FOR 24 HOUR EMERGENCY ACCESS.
  
 12. ALL ELEVATORS SHALL BE EQUIPPED WITH A REGION 7
 KEYWAY SYSTEM.
  
 ALL NEW ELEVATORS SHALL CONFORM TO THE FIRE FIGHTER?S
 EMERGENCY OPERATIONS REQUIREMENTS OF ASME A17.1/CSA
 B44, SAFETY CODE FOR ELEVATORS.
  
 ANY BUILDING THAT IS MORE THAN THREE STORIES HIGH OR IN
 WHICH THE VERTICAL DISTANCE BETWEEN THE BOTTOM TERMINAL
 LANDING AND THE TOP TERMINAL LANDING EXCEEDS 25 FEET
 MUST BE CONSTRUCTED TO CONTAIN AT LEAST ONE PASSENGER
 ELEVATOR THAT IS OPERATIONAL AND WILL ACCOMMODATE AN
 AMBULANCE STRETCHER 76 INCHES LONG AND 24 INCHES WIDE
 IN THE HORIZONTAL POSITION.
  
 13. TWO-WAY RADIO COMMUNICATIONS ENHANCEMENT SYSTEMS.
  
 NFPA 1, CHAPTER 11, BUILDING SERVICES; 11.10 TWO-WAY
 RADIO ENHANCEMENT SERVICES.
  
 11.10.1 IN ALL NEW AND EXISTING BUILDINGS, MINIMUM
 RADIO SIGNAL STRENGTH FOR FIRE DEPARTMENT
 COMMUNICATIONS SHALL BE MAINTAINED AT A LEVEL
 DETERMINED BY THE AHJ.
  
 CONTACT WILL NEED TO BE MADE TO MARK FILLA, PALM BEACH
 COUNTY PUBLIC SAFETY RADIO SYSTEMS MANAGER,
 [email protected], 561-233-0837; AS OUR RADIOS OPERATE
 ON THEIR SYSTEM FOR DETAILED RADIO FREQUENCY AND
 INSTALLATION INSTRUCTIONS.
  
  
 14. THE BUREAU'S APPROVAL OF THIS SUBMITTED PROJECT
 DOES NOT CONSTITUTE ITS FINAL REVIEW OR APPROVAL.
  
  
 15. THE BUREAU SHALL REVIEW ALL SUBMITTED BUILDING
 PLANS AT THE APPROPRIATE TIME AND IN ACCORDANCE WITH
 THE REQUIREMENTS OF ALL APPLICABLE CODES AND STANDARDS.
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]
  

Review Stop L LANDSCAPING
Rev No 5 Status P Date 03-15-2023 Cont ID  
Sent By rcaranci Date 03-15-2023 Time 15:19 Rev Time 0.00
Received By rcaranci Date 03-15-2023 Time 15:19 Sent To  
Notes
2023-03-15 15:20:30FROM: RAY CARANCI, SENIOR LANDSCAPE PLANNER
 561-822-1462
 PROJECT: 410 N ROSEMARY Z22080012
 MARCH 15, 2023
 I HAVE REVIEWED THE ABOVE REFERENCED PETITION, AND
 PROVIDE THE FOLLOWING COMMENTS:
  
  
 1. SATISFIED. SECTION 94-448 (D)(3) REQUIRES NATIVE
 TREES AND PALMS IN GOOD CONDITION TO BE PRESERVED ON
 SITE OR RELOCATED. ANSI A 300 (PART 5) STANDARDS
 SPECIFY EXAMPLES OF SUITABILITY RATINGS OF GOOD,
 MODERATE, OR POOR FOR RELOCATION. PROVIDE AN ARBORISTS
 REPORT RATING THE CONDITION AND RELOCATION POTENTIAL
 FOR THE NATIVE TREES AND PALMS.
 THERE ARE 7 SABAL PALMS THAT ARE FLORIDA NATIVE SPECIES
 INDICATED AS GOOD CONDITION ON THE TREE DISPOSITION
 PLAN AND THE ARBORISTS REPORT. REVISE DISPOSITION PLAN
 AND LIST TO SHOW AS RELOCATE.
 2. SATISFIED. PROVIDE THE INDIVIDUAL AND TOTAL CANOPY
 MITIGATION DUE FOR ANY PROPOSED REMOVALS. TREES
 PROPOSED TO BE REMOVED WITH A CANOPY DIAMETER OF 20
 FEET OR MORE SHOULD HAVE THE MITIGATION SQUARE FOOTAGE
 CALCULATED BASED ON THE ACTUAL DIAMETER. TREES LESS
 THAN 20 FEET CANOPY DIAMETER AND PALMS SHOULD SHOW THE
 CATEGORY MITIGATION DUE.
 REMOVE MITIGATION DUE FROM SABAL PALMS FOR RELOCATION.
 ALSO, SABAL PALMS ARE CATEGORY 3, AND IF REMOVED WOULD
 REQUIRE 100 SQ FT CANOPY MITIGATION EACH.
 3. MAKE THE FOLLOWING CORRECTIONS TO THE TREE
 DISPOSITION PLAN:
 ??? SATISFIED. BASED ON THE ARBORIST REPORT FINDINGS,
 IDENTIFY TREE #504 SPECIES.
 ??? SATISFIED. TREE #510 IS NOT LOCATED ON THE SUBJECT
 PROPERTY. NEED TO VERIFY IF IT HAS BEEN REMOVED.
  
 4. SATISFIED. PER SECTION 94-442(B)Q. SHOW TREES AND
 PALMS ON THE ADJACENT PROPERTIES WITHIN 10 FEET OF THE
 PROPERTY LINE.
  
 5. SATISFIED. SHEET A1.4 SHOWS THE DIAGRAMS OF THE
 REQUIRED AND PROVIDED PUBLIC AND PRIVATE OPEN SPACE
 AREAS FOR THE ZONING DISTRICT NWD-8 BUT LACKS THE
 INFORMATION OF THE REQUIRED AND PROVIDED SQUARE FOOTAGE
 AND HOW THE OPEN SPACE TYPES MEET THE REQUIREMENTS. THE
 PUBLIC OPEN SPACE AREAS IDENTIFIED AS COURTYARD DO NOT
 MEET SOME OF THE REQUIREMENTS AS SHOWN. SHOW HOW THE
 STANDARDS FOR THE TYPES OF OPEN SPACE ARE MET FOR
 VEGETATED AREAS AND TREE CANOPY SQUARE FOOTAGE BASED ON
 TABLE IV-8 ON THE LANDSCAPE PLAN. LANDSCAPE PLANS MUST
 MATCH THE ARCHITECTURAL PLANS AND CLEARLY IDENTIFY THE
 OPEN SPACE TYPE THEN DEMONSTRATE HOW THE REQUIREMENTS
 OF THAT TYPE ARE MET.
 11/3/22:
 PROVIDE THE FOLLOWING:
 PUBLIC OPEN SPACE
 ??? SATISFIED. OPEN SPACE SHEET A1.4- LABEL EACH OF THE
 4 AREAS SHOWN AS COURTYARD.
 ??? SATISFIED. OPEN SPACE SHEET A1.4-SHOW THE TOTAL
 REQUIRED AND TOTAL PROVIDED SQUARE FOOTAGE FOR PUBLIC
 OPEN SPACE MATCHING SHEET A0.2
 1/30/23 REQUIRED AND PROVIDED NEED TO BE CLEARLY SHOWN
 FOR PUBLIC AND PRIVATE OPEN SPACE.
 ??? SATISFIED. PROVIDE THE TREE SPECIES AND QUANTITIES
 COUNTED TOWARD TREE CANOPY PROVIDED FOR EACH COURTYARD
 SPACE ON SHEET L-1
 1/30/23 THE LIVE OAKS ARE BEING COUNTED AS TREE CANOPY
 FOR THE PUBLIC OPEN SPACE BUT ARE NO LONGER INSIDE THE
 PERIMETER OF THE OPEN SPACE.
 SEMI-PUBLIC OPEN SPACE
 ??? SATISFIED. OPEN SPACE SHEET A1.4-SHOW THE AREA
 COUNTED TOWARD WALK UP GARDEN AND SHOW THE VEGETATED
 AREA PROVIDED WITHIN THAT TO MEET THE 40% REQUIREMENT.
 ??? SATISFIED. SHOW THE REQUIRED 7 FOOT DEPTH ON THE
 DIAGRAM.
 PRIVATE OPEN SPACE
 ??? SATISFIED. OPEN SPACE SHEET A1.4- SHOW THE AREA
 COUNTED AND LABEL THE TYPE OF OPEN SPACE
 1/30/23 POOL DECK IS NOT AN OPEN SPACE TYPE. IS IT
 ROOFTOP GARDEN?
 ??? SATISFIED. SHOW THE VEGETATED AREA COUNTED TO MEET
 THE REQUIREMENT
 1/30/23 NOT SHOWN.
 ??? SATISFIED. PROVIDE THE TREE SPECIES AND QUANTITIES
 COUNTED TOWARD TREE CANOPY PROVIDED FOR EACH PRIVATE
 OPEN SPACE ON SHEET L-1
 1/30/23 NOT SHOWN.
  
  
  
 6. SATISFIED. SITE PLAN SHEET A1.0 DOES NOT MATCH THE
 LANDSCAPE PLAN.
  
 7. SATISFIED. IDENTIFY RELOCATED TREES OR PALMS ON THE
 PLANT LIST AND COUNT THEM TOWARD THE REQUIRED TREES IF
 THEY ARE TO BE USED ON SITE.
 SEE COMMENTS #1 AND #2.
  
  
 8. SATISFIED. PROVIDE CALCULATIONS FOR REQUIRED STREET
 TREES AT MAXIMUM SPACING EVERY 30 FEET OR PORTION
 THEREOF FOR EACH STREETSCAPE LENGTH, AND SHOW THE
 NUMBER PROVIDED PER SECTION 94-113 AND 94-116 FOR THE
 PROPOSED 4TH STREET ADJACENT TO THE SITE.
 DISREGARD 94-116 REFERENCE. SHOW THE CALCULATIONS FOR
 THE STREET TREE REQUIREMENT FOR EACH SIDE OF THE
 PROPOSED 4TH ST. IN THE STREET TREE REQUIREMENT CHART.
  
 9. SATISFIED. PROVIDE THE REQUIRED 4 FOOT WIDE PLANTING
 STRIP ALONG THE CURB FOR ALL STREETSCAPE SECTIONS AND
 PROVIDE A DETAIL AND SHOW THE LOCATIONS OF THE REQUIRED
 STRUCTURAL SOIL UNDER THE ADJACENT SIDEWALK OR
 HARDSCAPE AREAS.
 PROVIDE A SEPARATE EXHIBIT SHOWING THE LOCATIONS OF
 STRUCTURAL SOIL CLEARLY.
  
  
 10. SATISFIED. SHOW THE REQUIRED LANDSCAPE BUFFERS
 INSIDE ALL NON RIGHT OF WAY PROPERTY LINES ON THE
 LANDSCAPE AND SITE PLAN. BUFFER OF 5 FEET IS REQUIRED
 ON THE EAST SIDE OF THE SOUTH BUILDING AND AT THE NORTH
 PROPERTY LINE WITH THE TREES SPACED AT 30 FOOT
 INTERVALS. ADDRESS HOW THE STREETSCAPE WILL BE PLACED
 INSTEAD OF THE LANDSCAPE BUFFER THAT WOULD BE REQUIRED
 FOR THE PROPOSED 4TH ST.
 LANDSCAPING PROPOSED MEETS THE REQUIREMENTS, BUT
 CONFLICTS WITH PROPOSED DRAINAGE LINES WOULD PREVENT
 INSTALLATION.
 1/30/23 STILL CONFLICTS AS THERE IS A SPACING
 REQUIREMENT WITH ROOT BARRIER REQUIRED BY STORMWATER
 ENGINEER, AND TREES HAVE BEEN REMOVED IN THE SECTION
 ADJACENT TO THE LOADING AREA.
 2/27/23 THE BUFFER AND BUFFER TREES NEED TO BE PLACED
 ALONG THE ENTIRE LENGTH OF THE EAST PROPERTY LINE FOR
 THE SOUTH BUILDING AND THE EXFILTRATION DRAINAGE NEEDS
 TO BE REMOVED AND PLACED SOMEWHERE ELSE.
  
 11. SATISFIED. PROVIDE DETAIL ON HOW IMPROVEMENTS FOR
 THE PROPOSED 4TH STREET WILL BE INSTALLED ON THE
 ADJACENT PROPERTY, MODIFYING WHAT IS REQUIRED FOR THAT
 PROPERTY INCLUDING THE BUFFER AND STREETSCAPE
 REQUIREMENTS.
 STAFF NEEDS TO KNOW WHEN THE DESIGNED IMPROVEMENTS WILL
 BE INSTALLED AND WHO WILL MAINTAIN THEM.
  
 12. SATISFIED. ARTIFICIAL TURF AREAS PROPOSED MUST MEET
 THE REQUIREMENTS OF SECTION 94-451, INCLUDING ALL AREAS
 THAT ARE ALLOWED BY CODE MUST NOT BE VISIBLE FROM A
 ROAD OR STREET. ARTIFICIAL TURF CANNOT BE PLACED IN
 REQUIRED LANDSCAPE AREAS.
 THERE MUST BE A FENCE OR OTHER MEANS OF SCREENING
 INDICATED FOR THE ARTIFICIAL TURF AREA SO IT IS NOT
 VISIBLE FROM THE ROAD OR STREET. ARTIFICIAL TURF CANNOT
 DISPLACE REQUIRED LANDSCAPING IN THE 5 FOOT LANDSCAPE
 BUFFER.
 1/30/23 REMOVED FROM PLAN.
  
 13. SATISFIED. THE EXISTING FPL TRANSMISSION LINES
 ALONG ROSEMARY AVE. WILL BE REMOVED AND PLACED
 UNDERGROUND IN THE FUTURE AND THE STREETSCAPE DESIGNED.
 THE APPLICANT IS REQUIRED TO INSTALL AND MAINTAIN THE
 STREETSCAPE SO A PLAN MUST BE DEVELOPED THAT ACCOUNTS
 FOR THE FUTURE DESIGN OF THE STREETSCAPE.
 PER STAFF AND THE CRA, STREETSCAPE IS TO BE PROPOSED
 THAT MEETS THE CURRENT CODE REQUIREMENTS ON ROSEMARY
 AVE. TREES ARE TO BE LIVE OAKS MEETING THE 20 FOOT
 HEIGHT REQUIREMENT WITH THE 4 FOOT WIDTH PLANTING STRIP
 ADJACENT TO THE CURB.
  
 14. SATISFIED. SHOW ALL EXISTING AND PROPOSED WATER AND
 SEWER AND DRAINAGE LINES ON THE LANDSCAPE PLAN. SHOW
 LOCATIONS OF BACKFLOWS AND ADJUST LOCATIONS OF UTILITY
 LINES TO RESOLVE CONFLICTS WITH EXISTING AND PROPOSED
 TREES AND LANDSCAPING.
 DRAINAGE LINES AND EXFILTRATION TRENCHES LOCATED ALONG
 THE NORTH AND EAST BUFFER ARE IN CONFLICT WITH REQUIRED
 LANDSCAPING AND MUST BE PLACED IN A DIFFERENT LOCATION.
 1/30/23 EXFILTRATION STILL IN CONFLICT WITH BUFFER
 TREES, AND THE PROPOSED LOCATIONS OF THE BACKFLOWS
 RESTRICT THE SIDEWALK AND THE PLANTING AREAS FOR THE
 TREES.
 2/27/23 SEE COMMENT # 10.
  
 15. SATISFIED. SHOW COMPLIANCE WITH SECTION 94-445 L.
 PLANT SPECIES. A MINIMUM OF 60 PERCENT OF PLANT
 MATERIAL ADDED SHALL BE FLORIDA NATIVE OR DROUGHT
 TOLERANT SPECIES SELECTED FROM THE CITY LIST OR THE
 LIST OF SPECIES IN THE MOST RECENT EDITION OF SOUTH
 FLORIDA WATER MANAGEMENT DISTRICT WATERWISE SOUTH
 FLORIDA LANDSCAPES. PROVIDE THE ACTUAL PERCENTAGE BASED
 ON THE PLANT LIST.
  
 16. SATISFIED. PROVIDE SCREENING HEDGES FOR ALL GROUND
 MOUNTED VALVES AND EQUIPMENT AND ADD A NOTE THAT ALL
 EQUIPMENT WILL BE SCREENED.
  
 ADDITIONAL COMMENTS 11/3/22:
  
 17. SATISFIED. THE AUSTRALIAN PINE 515D MAY BE
 INDICATED AS TO BE REMOVED FROM THE ADJACENT CITY OWNED
 PARCEL. THIS IS A PROHIBITED INVASIVE EXOTIC SPECIES
 AND MAY BE A SAFETY PROBLEM DURING FUTURE CONSTRUCTION
 DUE TO ITS SIZE AND PROXIMITY TO THE PROPERTY LINE.
  
 18. SATISFIED. REVISE THE FLORIDA FRIENDLY POINTS CHART
 TO ADD 5 POINTS TO ACHIEVE THE REQUIRED 50 POINTS.
  
 ADDITIONAL COMMENTS 1/30/23:
  
 19. SATISFIED. JAPANESE BLUEBERRY AND SIMPSONS STOPPERS
 MUST MEET THE MINIMUM 12 FOOT REQUIRED SIZE, CORRECT
 THE PLANT LIST SPECIFICATION.
  
 20. SATISFIED. ADJUST STREET TREE SPACING ON ALL TREES
 TO MEET THE 30 FOOT MAXIMUM.
  
 21. SATISFIED. STREET TREES HAVE BEEN RELOCATED TO
 ADJACENT TO THE CURB PER CODE REQUIREMENT, 4 FOOT WIDE
 PLANTING STRIP NEEDS TO BE ADDED.
  
  
  
  
 ADDITIONAL COMMENTS 2/27/23:
 22. SATISFIED. THERE ARE NO OVERHEAD POWER LINES ALONG
 W. RAILROAD, SO THE STREET TREES CAN BE LIVE OAKS.
  
 23. SATISFIED. ARTIFICIAL TURF AREAS ARE SHOWN IN THE
 PRIVATE OPEN SPACE ON THE UPPER FLOORS, WHICH IS
 ALLOWED, BUT THE AREAS CANNOT BE COUNTED TOWARD
 VEGETATED AREA.
  
 24. CONDITIONALLY SATISFIED. PER SECTION 94-113(D)(3),
 THE PLANTING STRIPS IN THE STREETSCAPE ARE REQUIRED TO
 BE PLANTED WITH SHRUBS OR GROUNDCOVER, SOD IS NOT
 ACCEPTABLE.
  
 25. SATISFIED. PER THE DEFINITION IN SECTION 94-109,
 WALK UP GARDENS ARE INTENDED TO BE DESIGNED AS A BUFFER
 FOR GROUND FLOOR RESIDENTIAL UNITS. THE AREAS NEED TO
 HAVE MORE PLANTINGS RATHER THAN SOD.
  
 26. SATISFIED. SHEET A1.4A SHOWING THE PRIVATE OPEN
 SPACE AREAS AND THE CALCULATIONS FOR VEGETATED AREA AND
 TREE CANOPY ARE CORRECT, BUT THE LANDSCAPE PLAN SHEET
 L-2 DOES NOT MATCH THE DESIGNATED PERIMETER, THE
 VEGETATED AREA OR TREE COUNT.
  
 27. SATISFIED. SCREENING HEDGES MUST BE PROVIDED FOR
 THE GROUND MOUNTED UTILITIES AT THE NORTHWEST CORNER OF
 THE NORTH BUILDING AND THE NORTHWEST CORNER OF THE
 SOUTH BUILDING. THEY MUST BE SCREENED FROM N. ROSEMARY
 AVE.
  
  
 CONDITIONS OF APPROVAL
 1. PRIOR TO THE REMOVAL OR RELOCATION OF ANY TREES ON
 THE PROPERTY, A TREE ALTERATION PERMIT SHALL BE
 SUBMITTED, REVIEWED AND APPROVED BY THE DEVELOPMENT
 SERVICES DEPARTMENT, PLANNING DIVISION.
 2. THE APPLICANT, SUCCESSORS AND ASSIGNS SHALL BE
 RESPONSIBLE FOR THE PERMITTING AND INSTALLATION OF THE
 STREET TREES AND RIGHT OF WAY LANDSCAPING AND
 IRRIGATION APPROVED WITH THIS PETITION.
  
 3. THE APPLICANT, SUCCESSORS AND ASSIGNS SHALL BE
 RESPONSIBLE FOR THE MAINTENANCE OF THE STREET TREES AND
 RIGHT OF WAY LANDSCAPING AND IRRIGATION. THIS WILL BE
 THROUGH A SEPARATE MAINTENANCE AGREEMENT WITH THE CITY.
  
 4. PRIOR TO FINAL SITE PLAN APPROVAL, THE APPLICANT
 SHALL SUBMIT FINAL LANDSCAPE PLANS THAT INCORPORATE THE
 TYPICAL PLANTING PLANS INTO THE OVERALL PLAN AND IN A
 LARGER SCALE.
  

Review Stop L LANDSCAPING
Rev No 4 Status F Date 02-27-2023 Cont ID  
Sent By rcaranci Date 02-27-2023 Time 16:47 Rev Time 0.00
Received By rcaranci Date 02-27-2023 Time 16:47 Sent To  
Notes
2023-02-27 16:48:04FROM: RAY CARANCI, SENIOR LANDSCAPE PLANNER
 561-822-1462
 PROJECT: 410 N ROSEMARY Z22080012
 FEBRUARY 27, 2023
 I HAVE REVIEWED THE ABOVE REFERENCED PETITION, AND
 PROVIDE THE FOLLOWING COMMENTS:
  
  
 1. SATISFIED. SECTION 94-448 (D)(3) REQUIRES NATIVE
 TREES AND PALMS IN GOOD CONDITION TO BE PRESERVED ON
 SITE OR RELOCATED. ANSI A 300 (PART 5) STANDARDS
 SPECIFY EXAMPLES OF SUITABILITY RATINGS OF GOOD,
 MODERATE, OR POOR FOR RELOCATION. PROVIDE AN ARBORISTS
 REPORT RATING THE CONDITION AND RELOCATION POTENTIAL
 FOR THE NATIVE TREES AND PALMS.
 THERE ARE 7 SABAL PALMS THAT ARE FLORIDA NATIVE SPECIES
 INDICATED AS GOOD CONDITION ON THE TREE DISPOSITION
 PLAN AND THE ARBORISTS REPORT. REVISE DISPOSITION PLAN
 AND LIST TO SHOW AS RELOCATE.
 2. SATISFIED. PROVIDE THE INDIVIDUAL AND TOTAL CANOPY
 MITIGATION DUE FOR ANY PROPOSED REMOVALS. TREES
 PROPOSED TO BE REMOVED WITH A CANOPY DIAMETER OF 20
 FEET OR MORE SHOULD HAVE THE MITIGATION SQUARE FOOTAGE
 CALCULATED BASED ON THE ACTUAL DIAMETER. TREES LESS
 THAN 20 FEET CANOPY DIAMETER AND PALMS SHOULD SHOW THE
 CATEGORY MITIGATION DUE.
 REMOVE MITIGATION DUE FROM SABAL PALMS FOR RELOCATION.
 ALSO, SABAL PALMS ARE CATEGORY 3, AND IF REMOVED WOULD
 REQUIRE 100 SQ FT CANOPY MITIGATION EACH.
 3. MAKE THE FOLLOWING CORRECTIONS TO THE TREE
 DISPOSITION PLAN:
 ??? SATISFIED. BASED ON THE ARBORIST REPORT FINDINGS,
 IDENTIFY TREE #504 SPECIES.
 ??? SATISFIED. TREE #510 IS NOT LOCATED ON THE SUBJECT
 PROPERTY. NEED TO VERIFY IF IT HAS BEEN REMOVED.
  
 4. SATISFIED. PER SECTION 94-442(B)Q. SHOW TREES AND
 PALMS ON THE ADJACENT PROPERTIES WITHIN 10 FEET OF THE
 PROPERTY LINE.
  
 5. SATISFIED. SHEET A1.4 SHOWS THE DIAGRAMS OF THE
 REQUIRED AND PROVIDED PUBLIC AND PRIVATE OPEN SPACE
 AREAS FOR THE ZONING DISTRICT NWD-8 BUT LACKS THE
 INFORMATION OF THE REQUIRED AND PROVIDED SQUARE FOOTAGE
 AND HOW THE OPEN SPACE TYPES MEET THE REQUIREMENTS. THE
 PUBLIC OPEN SPACE AREAS IDENTIFIED AS COURTYARD DO NOT
 MEET SOME OF THE REQUIREMENTS AS SHOWN. SHOW HOW THE
 STANDARDS FOR THE TYPES OF OPEN SPACE ARE MET FOR
 VEGETATED AREAS AND TREE CANOPY SQUARE FOOTAGE BASED ON
 TABLE IV-8 ON THE LANDSCAPE PLAN. LANDSCAPE PLANS MUST
 MATCH THE ARCHITECTURAL PLANS AND CLEARLY IDENTIFY THE
 OPEN SPACE TYPE THEN DEMONSTRATE HOW THE REQUIREMENTS
 OF THAT TYPE ARE MET.
 11/3/22:
 PROVIDE THE FOLLOWING:
 PUBLIC OPEN SPACE
 ??? SATISFIED. OPEN SPACE SHEET A1.4- LABEL EACH OF THE
 4 AREAS SHOWN AS COURTYARD.
 ??? SATISFIED. OPEN SPACE SHEET A1.4-SHOW THE TOTAL
 REQUIRED AND TOTAL PROVIDED SQUARE FOOTAGE FOR PUBLIC
 OPEN SPACE MATCHING SHEET A0.2
 1/30/23 REQUIRED AND PROVIDED NEED TO BE CLEARLY SHOWN
 FOR PUBLIC AND PRIVATE OPEN SPACE.
 ??? SATISFIED. PROVIDE THE TREE SPECIES AND QUANTITIES
 COUNTED TOWARD TREE CANOPY PROVIDED FOR EACH COURTYARD
 SPACE ON SHEET L-1
 1/30/23 THE LIVE OAKS ARE BEING COUNTED AS TREE CANOPY
 FOR THE PUBLIC OPEN SPACE BUT ARE NO LONGER INSIDE THE
 PERIMETER OF THE OPEN SPACE.
 SEMI-PUBLIC OPEN SPACE
 ??? SATISFIED. OPEN SPACE SHEET A1.4-SHOW THE AREA
 COUNTED TOWARD WALK UP GARDEN AND SHOW THE VEGETATED
 AREA PROVIDED WITHIN THAT TO MEET THE 40% REQUIREMENT.
 ??? SATISFIED. SHOW THE REQUIRED 7 FOOT DEPTH ON THE
 DIAGRAM.
 PRIVATE OPEN SPACE
 ??? SATISFIED. OPEN SPACE SHEET A1.4- SHOW THE AREA
 COUNTED AND LABEL THE TYPE OF OPEN SPACE
 1/30/23 POOL DECK IS NOT AN OPEN SPACE TYPE. IS IT
 ROOFTOP GARDEN?
 ??? SATISFIED. SHOW THE VEGETATED AREA COUNTED TO MEET
 THE REQUIREMENT
 1/30/23 NOT SHOWN.
 ??? SATISFIED. PROVIDE THE TREE SPECIES AND QUANTITIES
 COUNTED TOWARD TREE CANOPY PROVIDED FOR EACH PRIVATE
 OPEN SPACE ON SHEET L-1
 1/30/23 NOT SHOWN.
  
  
  
 6. SATISFIED. SITE PLAN SHEET A1.0 DOES NOT MATCH THE
 LANDSCAPE PLAN.
  
 7. SATISFIED. IDENTIFY RELOCATED TREES OR PALMS ON THE
 PLANT LIST AND COUNT THEM TOWARD THE REQUIRED TREES IF
 THEY ARE TO BE USED ON SITE.
 SEE COMMENTS #1 AND #2.
  
  
 8. SATISFIED. PROVIDE CALCULATIONS FOR REQUIRED STREET
 TREES AT MAXIMUM SPACING EVERY 30 FEET OR PORTION
 THEREOF FOR EACH STREETSCAPE LENGTH, AND SHOW THE
 NUMBER PROVIDED PER SECTION 94-113 AND 94-116 FOR THE
 PROPOSED 4TH STREET ADJACENT TO THE SITE.
 DISREGARD 94-116 REFERENCE. SHOW THE CALCULATIONS FOR
 THE STREET TREE REQUIREMENT FOR EACH SIDE OF THE
 PROPOSED 4TH ST. IN THE STREET TREE REQUIREMENT CHART.
  
 9. SATISFIED. PROVIDE THE REQUIRED 4 FOOT WIDE PLANTING
 STRIP ALONG THE CURB FOR ALL STREETSCAPE SECTIONS AND
 PROVIDE A DETAIL AND SHOW THE LOCATIONS OF THE REQUIRED
 STRUCTURAL SOIL UNDER THE ADJACENT SIDEWALK OR
 HARDSCAPE AREAS.
 PROVIDE A SEPARATE EXHIBIT SHOWING THE LOCATIONS OF
 STRUCTURAL SOIL CLEARLY.
  
  
 10. PARTIALLY SATISFIED. SHOW THE REQUIRED LANDSCAPE
 BUFFERS INSIDE ALL NON RIGHT OF WAY PROPERTY LINES ON
 THE LANDSCAPE AND SITE PLAN. BUFFER OF 5 FEET IS
 REQUIRED ON THE EAST SIDE OF THE SOUTH BUILDING AND AT
 THE NORTH PROPERTY LINE WITH THE TREES SPACED AT 30
 FOOT INTERVALS. ADDRESS HOW THE STREETSCAPE WILL BE
 PLACED INSTEAD OF THE LANDSCAPE BUFFER THAT WOULD BE
 REQUIRED FOR THE PROPOSED 4TH ST.
 LANDSCAPING PROPOSED MEETS THE REQUIREMENTS, BUT
 CONFLICTS WITH PROPOSED DRAINAGE LINES WOULD PREVENT
 INSTALLATION.
 1/30/23 STILL CONFLICTS AS THERE IS A SPACING
 REQUIREMENT WITH ROOT BARRIER REQUIRED BY STORMWATER
 ENGINEER, AND TREES HAVE BEEN REMOVED IN THE SECTION
 ADJACENT TO THE LOADING AREA.
 2/27/23 THE BUFFER AND BUFFER TREES NEED TO BE PLACED
 ALONG THE ENTIRE LENGTH OF THE EAST PROPERTY LINE FOR
 THE SOUTH BUILDING AND THE EXFILTRATION DRAINAGE NEEDS
 TO BE REMOVED AND PLACED SOMEWHERE ELSE.
  
 11. SATISFIED. PROVIDE DETAIL ON HOW IMPROVEMENTS FOR
 THE PROPOSED 4TH STREET WILL BE INSTALLED ON THE
 ADJACENT PROPERTY, MODIFYING WHAT IS REQUIRED FOR THAT
 PROPERTY INCLUDING THE BUFFER AND STREETSCAPE
 REQUIREMENTS.
 STAFF NEEDS TO KNOW WHEN THE DESIGNED IMPROVEMENTS WILL
 BE INSTALLED AND WHO WILL MAINTAIN THEM.
  
 12. SATISFIED. ARTIFICIAL TURF AREAS PROPOSED MUST MEET
 THE REQUIREMENTS OF SECTION 94-451, INCLUDING ALL AREAS
 THAT ARE ALLOWED BY CODE MUST NOT BE VISIBLE FROM A
 ROAD OR STREET. ARTIFICIAL TURF CANNOT BE PLACED IN
 REQUIRED LANDSCAPE AREAS.
 THERE MUST BE A FENCE OR OTHER MEANS OF SCREENING
 INDICATED FOR THE ARTIFICIAL TURF AREA SO IT IS NOT
 VISIBLE FROM THE ROAD OR STREET. ARTIFICIAL TURF CANNOT
 DISPLACE REQUIRED LANDSCAPING IN THE 5 FOOT LANDSCAPE
 BUFFER.
 1/30/23 REMOVED FROM PLAN.
  
 13. SATISFIED. THE EXISTING FPL TRANSMISSION LINES
 ALONG ROSEMARY AVE. WILL BE REMOVED AND PLACED
 UNDERGROUND IN THE FUTURE AND THE STREETSCAPE DESIGNED.
 THE APPLICANT IS REQUIRED TO INSTALL AND MAINTAIN THE
 STREETSCAPE SO A PLAN MUST BE DEVELOPED THAT ACCOUNTS
 FOR THE FUTURE DESIGN OF THE STREETSCAPE.
 PER STAFF AND THE CRA, STREETSCAPE IS TO BE PROPOSED
 THAT MEETS THE CURRENT CODE REQUIREMENTS ON ROSEMARY
 AVE. TREES ARE TO BE LIVE OAKS MEETING THE 20 FOOT
 HEIGHT REQUIREMENT WITH THE 4 FOOT WIDTH PLANTING STRIP
 ADJACENT TO THE CURB.
  
 14. PARTIALLY SATISFIED. SHOW ALL EXISTING AND PROPOSED
 WATER AND SEWER AND DRAINAGE LINES ON THE LANDSCAPE
 PLAN. SHOW LOCATIONS OF BACKFLOWS AND ADJUST LOCATIONS
 OF UTILITY LINES TO RESOLVE CONFLICTS WITH EXISTING AND
 PROPOSED TREES AND LANDSCAPING.
 DRAINAGE LINES AND EXFILTRATION TRENCHES LOCATED ALONG
 THE NORTH AND EAST BUFFER ARE IN CONFLICT WITH REQUIRED
 LANDSCAPING AND MUST BE PLACED IN A DIFFERENT LOCATION.
 1/30/23 EXFILTRATION STILL IN CONFLICT WITH BUFFER
 TREES, AND THE PROPOSED LOCATIONS OF THE BACKFLOWS
 RESTRICT THE SIDEWALK AND THE PLANTING AREAS FOR THE
 TREES.
 2/27/23 SEE COMMENT # 10.
  
 15. SATISFIED. SHOW COMPLIANCE WITH SECTION 94-445 L.
 PLANT SPECIES. A MINIMUM OF 60 PERCENT OF PLANT
 MATERIAL ADDED SHALL BE FLORIDA NATIVE OR DROUGHT
 TOLERANT SPECIES SELECTED FROM THE CITY LIST OR THE
 LIST OF SPECIES IN THE MOST RECENT EDITION OF SOUTH
 FLORIDA WATER MANAGEMENT DISTRICT WATERWISE SOUTH
 FLORIDA LANDSCAPES. PROVIDE THE ACTUAL PERCENTAGE BASED
 ON THE PLANT LIST.
  
 16. SATISFIED. PROVIDE SCREENING HEDGES FOR ALL GROUND
 MOUNTED VALVES AND EQUIPMENT AND ADD A NOTE THAT ALL
 EQUIPMENT WILL BE SCREENED.
  
 ADDITIONAL COMMENTS 11/3/22:
  
 17. SATISFIED. THE AUSTRALIAN PINE 515D MAY BE
 INDICATED AS TO BE REMOVED FROM THE ADJACENT CITY OWNED
 PARCEL. THIS IS A PROHIBITED INVASIVE EXOTIC SPECIES
 AND MAY BE A SAFETY PROBLEM DURING FUTURE CONSTRUCTION
 DUE TO ITS SIZE AND PROXIMITY TO THE PROPERTY LINE.
  
 18. SATISFIED. REVISE THE FLORIDA FRIENDLY POINTS CHART
 TO ADD 5 POINTS TO ACHIEVE THE REQUIRED 50 POINTS.
  
 ADDITIONAL COMMENTS 1/30/23:
  
 19. SATISFIED. JAPANESE BLUEBERRY AND SIMPSONS STOPPERS
 MUST MEET THE MINIMUM 12 FOOT REQUIRED SIZE, CORRECT
 THE PLANT LIST SPECIFICATION.
  
 20. SATISFIED. ADJUST STREET TREE SPACING ON ALL TREES
 TO MEET THE 30 FOOT MAXIMUM.
  
 21. SATISFIED. STREET TREES HAVE BEEN RELOCATED TO
 ADJACENT TO THE CURB PER CODE REQUIREMENT, 4 FOOT WIDE
 PLANTING STRIP NEEDS TO BE ADDED.
  
  
  
  
 ADDITIONAL COMMENTS 2/27/23:
 22. THERE ARE NO OVERHEAD POWER LINES ALONG W.
 RAILROAD, SO THE STREET TREES CAN BE LIVE OAKS.
  
 23. ARTIFICIAL TURF AREAS ARE SHOWN IN THE PRIVATE OPEN
 SPACE ON THE UPPER FLOORS, WHICH IS ALLOWED, BUT THE
 AREAS CANNOT BE COUNTED TOWARD VEGETATED AREA.
  
 24. PER SECTION 94-113(D)(3), THE PLANTING STRIPS IN
 THE STREETSCAPE ARE REQUIRED TO BE PLANTED WITH SHRUBS
 OR GROUNDCOVER, SOD IS NOT ACCEPTABLE.
  
 25. PER THE DEFINITION IN SECTION 94-109, WALK UP
 GARDENS ARE INTENDED TO BE DESIGNED AS A BUFFER FOR
 GROUND FLOOR RESIDENTIAL UNITS. THE AREAS NEED TO HAVE
 MORE PLANTINGS RATHER THAN SOD.
  
 26. SHEET A1.4A SHOWING THE PRIVATE OPEN SPACE AREAS
 AND THE CALCULATIONS FOR VEGETATED AREA AND TREE CANOPY
 ARE CORRECT, BUT THE LANDSCAPE PLAN SHEET L-2 DOES NOT
 MATCH THE DESIGNATED PERIMETER, THE VEGETATED AREA OR
 TREE COUNT.
  
 27. SCREENING HEDGES MUST BE PROVIDED FOR THE GROUND
 MOUNTED UTILITIES AT THE NORTHWEST CORNER OF THE NORTH
 BUILDING AND THE NORTHWEST CORNER OF THE SOUTH
 BUILDING. THEY MUST BE SCREENED FROM N. ROSEMARY AVE.
  
  
 CONDITIONS OF APPROVAL
 1. PRIOR TO THE REMOVAL OR RELOCATION OF ANY TREES ON
 THE PROPERTY, A TREE ALTERATION PERMIT SHALL BE
 SUBMITTED, REVIEWED AND APPROVED BY THE DEVELOPMENT
 SERVICES DEPARTMENT, PLANNING DIVISION.
 2. THE APPLICANT, SUCCESSORS AND ASSIGNS SHALL BE
 RESPONSIBLE FOR THE PERMITTING AND INSTALLATION OF THE
 STREET TREES AND RIGHT OF WAY LANDSCAPING AND
 IRRIGATION APPROVED WITH THIS PETITION.
 3. THE APPLICANT, SUCCESSORS AND ASSIGNS SHALL BE
 RESPONSIBLE FOR THE MAINTENANCE OF THE STREET TREES AND
 RIGHT OF WAY LANDSCAPING AND IRRIGATION. THIS WILL BE
 THROUGH A SEPARATE MAINTENANCE AGREEMENT WITH THE CITY.
  

Review Stop L LANDSCAPING
Rev No 3 Status F Date 01-30-2023 Cont ID  
Sent By rcaranci Date 01-30-2023 Time 13:10 Rev Time 0.00
Received By rcaranci Date 01-30-2023 Time 13:10 Sent To  
Notes
2023-01-30 13:11:12FROM: RAY CARANCI, SENIOR LANDSCAPE PLANNER
 561-822-1462
 PROJECT: 410 N ROSEMARY Z22080012
 JANUARY 30, 2023
 I HAVE REVIEWED THE ABOVE REFERENCED PETITION, AND
 PROVIDE THE FOLLOWING COMMENTS:
  
  
 1. SATISFIED. SECTION 94-448 (D)(3) REQUIRES NATIVE
 TREES AND PALMS IN GOOD CONDITION TO BE PRESERVED ON
 SITE OR RELOCATED. ANSI A 300 (PART 5) STANDARDS
 SPECIFY EXAMPLES OF SUITABILITY RATINGS OF GOOD,
 MODERATE, OR POOR FOR RELOCATION. PROVIDE AN ARBORISTS
 REPORT RATING THE CONDITION AND RELOCATION POTENTIAL
 FOR THE NATIVE TREES AND PALMS.
 THERE ARE 7 SABAL PALMS THAT ARE FLORIDA NATIVE SPECIES
 INDICATED AS GOOD CONDITION ON THE TREE DISPOSITION
 PLAN AND THE ARBORISTS REPORT. REVISE DISPOSITION PLAN
 AND LIST TO SHOW AS RELOCATE.
 2. SATISFIED. PROVIDE THE INDIVIDUAL AND TOTAL CANOPY
 MITIGATION DUE FOR ANY PROPOSED REMOVALS. TREES
 PROPOSED TO BE REMOVED WITH A CANOPY DIAMETER OF 20
 FEET OR MORE SHOULD HAVE THE MITIGATION SQUARE FOOTAGE
 CALCULATED BASED ON THE ACTUAL DIAMETER. TREES LESS
 THAN 20 FEET CANOPY DIAMETER AND PALMS SHOULD SHOW THE
 CATEGORY MITIGATION DUE.
 REMOVE MITIGATION DUE FROM SABAL PALMS FOR RELOCATION.
 ALSO, SABAL PALMS ARE CATEGORY 3, AND IF REMOVED WOULD
 REQUIRE 100 SQ FT CANOPY MITIGATION EACH.
 3. MAKE THE FOLLOWING CORRECTIONS TO THE TREE
 DISPOSITION PLAN:
 ??? SATISFIED. BASED ON THE ARBORIST REPORT FINDINGS,
 IDENTIFY TREE #504 SPECIES.
 ??? SATISFIED. TREE #510 IS NOT LOCATED ON THE SUBJECT
 PROPERTY. NEED TO VERIFY IF IT HAS BEEN REMOVED.
  
 4. SATISFIED. PER SECTION 94-442(B)Q. SHOW TREES AND
 PALMS ON THE ADJACENT PROPERTIES WITHIN 10 FEET OF THE
 PROPERTY LINE.
  
 5. PARTIALLY SATISFIED. SHEET A1.4 SHOWS THE DIAGRAMS
 OF THE REQUIRED AND PROVIDED PUBLIC AND PRIVATE OPEN
 SPACE AREAS FOR THE ZONING DISTRICT NWD-8 BUT LACKS THE
 INFORMATION OF THE REQUIRED AND PROVIDED SQUARE FOOTAGE
 AND HOW THE OPEN SPACE TYPES MEET THE REQUIREMENTS. THE
 PUBLIC OPEN SPACE AREAS IDENTIFIED AS COURTYARD DO NOT
 MEET SOME OF THE REQUIREMENTS AS SHOWN. SHOW HOW THE
 STANDARDS FOR THE TYPES OF OPEN SPACE ARE MET FOR
 VEGETATED AREAS AND TREE CANOPY SQUARE FOOTAGE BASED ON
 TABLE IV-8 ON THE LANDSCAPE PLAN. LANDSCAPE PLANS MUST
 MATCH THE ARCHITECTURAL PLANS AND CLEARLY IDENTIFY THE
 OPEN SPACE TYPE THEN DEMONSTRATE HOW THE REQUIREMENTS
 OF THAT TYPE ARE MET.
 11/3/22:
 PROVIDE THE FOLLOWING:
 PUBLIC OPEN SPACE
 ??? SATISFIED. OPEN SPACE SHEET A1.4- LABEL EACH OF THE
 4 AREAS SHOWN AS COURTYARD.
 ??? NOT SATISFIED. OPEN SPACE SHEET A1.4-SHOW THE TOTAL
 REQUIRED AND TOTAL PROVIDED SQUARE FOOTAGE FOR PUBLIC
 OPEN SPACE MATCHING SHEET A0.2
 1/30/23 REQUIRED AND PROVIDED NEED TO BE CLEARLY SHOWN
 FOR PUBLIC AND PRIVATE OPEN SPACE.
 ??? PARTIALLY SATISFIED. PROVIDE THE TREE SPECIES AND
 QUANTITIES COUNTED TOWARD TREE CANOPY PROVIDED FOR EACH
 COURTYARD SPACE ON SHEET L-1
 1/30/23 THE LIVE OAKS ARE BEING COUNTED AS TREE CANOPY
 FOR THE PUBLIC OPEN SPACE BUT ARE NO LONGER INSIDE THE
 PERIMETER OF THE OPEN SPACE.
 SEMI-PUBLIC OPEN SPACE
 ??? SATISFIED. OPEN SPACE SHEET A1.4-SHOW THE AREA
 COUNTED TOWARD WALK UP GARDEN AND SHOW THE VEGETATED
 AREA PROVIDED WITHIN THAT TO MEET THE 40% REQUIREMENT.
 ??? SATISFIED. SHOW THE REQUIRED 7 FOOT DEPTH ON THE
 DIAGRAM.
 PRIVATE OPEN SPACE
 ??? PARTIALLY SATISFIED. OPEN SPACE SHEET A1.4- SHOW
 THE AREA COUNTED AND LABEL THE TYPE OF OPEN SPACE
 1/30/23 POOL DECK IS NOT AN OPEN SPACE TYPE. IS IT
 ROOFTOP GARDEN?
 ??? PARTIALLY SATISFIED. SHOW THE VEGETATED AREA
 COUNTED TO MEET THE REQUIREMENT
 1/30/23 NOT SHOWN.
 ??? NOT SATISFIED. PROVIDE THE TREE SPECIES AND
 QUANTITIES COUNTED TOWARD TREE CANOPY PROVIDED FOR EACH
 PRIVATE OPEN SPACE ON SHEET L-1
 1/30/23 NOT SHOWN.
  
  
  
 6. SATISFIED. SITE PLAN SHEET A1.0 DOES NOT MATCH THE
 LANDSCAPE PLAN.
  
 7. SATISFIED. IDENTIFY RELOCATED TREES OR PALMS ON THE
 PLANT LIST AND COUNT THEM TOWARD THE REQUIRED TREES IF
 THEY ARE TO BE USED ON SITE.
 SEE COMMENTS #1 AND #2.
  
  
 8. SATISFIED. PROVIDE CALCULATIONS FOR REQUIRED STREET
 TREES AT MAXIMUM SPACING EVERY 30 FEET OR PORTION
 THEREOF FOR EACH STREETSCAPE LENGTH, AND SHOW THE
 NUMBER PROVIDED PER SECTION 94-113 AND 94-116 FOR THE
 PROPOSED 4TH STREET ADJACENT TO THE SITE.
 DISREGARD 94-116 REFERENCE. SHOW THE CALCULATIONS FOR
 THE STREET TREE REQUIREMENT FOR EACH SIDE OF THE
 PROPOSED 4TH ST. IN THE STREET TREE REQUIREMENT CHART.
  
 9. SATISFIED. PROVIDE THE REQUIRED 4 FOOT WIDE PLANTING
 STRIP ALONG THE CURB FOR ALL STREETSCAPE SECTIONS AND
 PROVIDE A DETAIL AND SHOW THE LOCATIONS OF THE REQUIRED
 STRUCTURAL SOIL UNDER THE ADJACENT SIDEWALK OR
 HARDSCAPE AREAS.
 PROVIDE A SEPARATE EXHIBIT SHOWING THE LOCATIONS OF
 STRUCTURAL SOIL CLEARLY.
  
  
 10. PARTIALLY SATISFIED. SHOW THE REQUIRED LANDSCAPE
 BUFFERS INSIDE ALL NON RIGHT OF WAY PROPERTY LINES ON
 THE LANDSCAPE AND SITE PLAN. BUFFER OF 5 FEET IS
 REQUIRED ON THE EAST SIDE OF THE SOUTH BUILDING AND AT
 THE NORTH PROPERTY LINE WITH THE TREES SPACED AT 30
 FOOT INTERVALS. ADDRESS HOW THE STREETSCAPE WILL BE
 PLACED INSTEAD OF THE LANDSCAPE BUFFER THAT WOULD BE
 REQUIRED FOR THE PROPOSED 4TH ST.
 LANDSCAPING PROPOSED MEETS THE REQUIREMENTS, BUT
 CONFLICTS WITH PROPOSED DRAINAGE LINES WOULD PREVENT
 INSTALLATION.
 1/30/23 STILL CONFLICTS AS THERE IS A SPACING
 REQUIREMENT WITH ROOT BARRIER REQUIRED BY STORMWATER
 ENGINEER, AND TREES HAVE BEEN REMOVED IN THE SECTION
 ADJACENT TO THE LOADING AREA.
  
 11. SATISFIED. PROVIDE DETAIL ON HOW IMPROVEMENTS FOR
 THE PROPOSED 4TH STREET WILL BE INSTALLED ON THE
 ADJACENT PROPERTY, MODIFYING WHAT IS REQUIRED FOR THAT
 PROPERTY INCLUDING THE BUFFER AND STREETSCAPE
 REQUIREMENTS.
 STAFF NEEDS TO KNOW WHEN THE DESIGNED IMPROVEMENTS WILL
 BE INSTALLED AND WHO WILL MAINTAIN THEM.
  
 12. SATISFIED. ARTIFICIAL TURF AREAS PROPOSED MUST MEET
 THE REQUIREMENTS OF SECTION 94-451, INCLUDING ALL AREAS
 THAT ARE ALLOWED BY CODE MUST NOT BE VISIBLE FROM A
 ROAD OR STREET. ARTIFICIAL TURF CANNOT BE PLACED IN
 REQUIRED LANDSCAPE AREAS.
 THERE MUST BE A FENCE OR OTHER MEANS OF SCREENING
 INDICATED FOR THE ARTIFICIAL TURF AREA SO IT IS NOT
 VISIBLE FROM THE ROAD OR STREET. ARTIFICIAL TURF CANNOT
 DISPLACE REQUIRED LANDSCAPING IN THE 5 FOOT LANDSCAPE
 BUFFER.
 1/30/23 REMOVED FROM PLAN.
  
 13. SATISFIED. THE EXISTING FPL TRANSMISSION LINES
 ALONG ROSEMARY AVE. WILL BE REMOVED AND PLACED
 UNDERGROUND IN THE FUTURE AND THE STREETSCAPE DESIGNED.
 THE APPLICANT IS REQUIRED TO INSTALL AND MAINTAIN THE
 STREETSCAPE SO A PLAN MUST BE DEVELOPED THAT ACCOUNTS
 FOR THE FUTURE DESIGN OF THE STREETSCAPE.
 PER STAFF AND THE CRA, STREETSCAPE IS TO BE PROPOSED
 THAT MEETS THE CURRENT CODE REQUIREMENTS ON ROSEMARY
 AVE. TREES ARE TO BE LIVE OAKS MEETING THE 20 FOOT
 HEIGHT REQUIREMENT WITH THE 4 FOOT WIDTH PLANTING STRIP
 ADJACENT TO THE CURB.
  
 14. PARTIALLY SATISFIED. SHOW ALL EXISTING AND PROPOSED
 WATER AND SEWER AND DRAINAGE LINES ON THE LANDSCAPE
 PLAN. SHOW LOCATIONS OF BACKFLOWS AND ADJUST LOCATIONS
 OF UTILITY LINES TO RESOLVE CONFLICTS WITH EXISTING AND
 PROPOSED TREES AND LANDSCAPING.
 DRAINAGE LINES AND EXFILTRATION TRENCHES LOCATED ALONG
 THE NORTH AND EAST BUFFER ARE IN CONFLICT WITH REQUIRED
 LANDSCAPING AND MUST BE PLACED IN A DIFFERENT LOCATION.
 1/30/23 EXFILTRATION STILL IN CONFLICT WITH BUFFER
 TREES, AND THE PROPOSED LOCATIONS OF THE BACKFLOWS
 RESTRICT THE SIDEWALK AND THE PLANTING AREAS FOR THE
 TREES.
  
 15. SATISFIED. SHOW COMPLIANCE WITH SECTION 94-445 L.
 PLANT SPECIES. A MINIMUM OF 60 PERCENT OF PLANT
 MATERIAL ADDED SHALL BE FLORIDA NATIVE OR DROUGHT
 TOLERANT SPECIES SELECTED FROM THE CITY LIST OR THE
 LIST OF SPECIES IN THE MOST RECENT EDITION OF SOUTH
 FLORIDA WATER MANAGEMENT DISTRICT WATERWISE SOUTH
 FLORIDA LANDSCAPES. PROVIDE THE ACTUAL PERCENTAGE BASED
 ON THE PLANT LIST.
  
 16. SATISFIED. PROVIDE SCREENING HEDGES FOR ALL GROUND
 MOUNTED VALVES AND EQUIPMENT AND ADD A NOTE THAT ALL
 EQUIPMENT WILL BE SCREENED.
  
 ADDITIONAL COMMENTS 11/3/22:
  
 17. SATISFIED. THE AUSTRALIAN PINE 515D MAY BE
 INDICATED AS TO BE REMOVED FROM THE ADJACENT CITY OWNED
 PARCEL. THIS IS A PROHIBITED INVASIVE EXOTIC SPECIES
 AND MAY BE A SAFETY PROBLEM DURING FUTURE CONSTRUCTION
 DUE TO ITS SIZE AND PROXIMITY TO THE PROPERTY LINE.
  
 18. SATISFIED. REVISE THE FLORIDA FRIENDLY POINTS CHART
 TO ADD 5 POINTS TO ACHIEVE THE REQUIRED 50 POINTS.
  
 ADDITIONAL COMMENTS 1/30/23:
  
 19. JAPANESE BLUEBERRY AND SIMPSONS STOPPERS MUST MEET
 THE MINIMUM 12 FOOT REQUIRED SIZE, CORRECT THE PLANT
 LIST SPECIFICATION.
  
 20. ADJUST STREET TREE SPACING ON ALL TREES TO MEET THE
 30 FOOT MAXIMUM.
  
 21. STREET TREES HAVE BEEN RELOCATED TO ADJACENT TO THE
 CURB PER CODE REQUIREMENT, 4 FOOT WIDE PLANTING STRIP
 NEEDS TO BE ADDED.
 CONDITIONS OF APPROVAL
 1. PRIOR TO THE REMOVAL OR RELOCATION OF ANY TREES ON
 THE PROPERTY, A TREE ALTERATION PERMIT SHALL BE
 SUBMITTED, REVIEWED AND APPROVED BY THE DEVELOPMENT
 SERVICES DEPARTMENT, PLANNING DIVISION.
 2. THE APPLICANT, SUCCESSORS AND ASSIGNS SHALL BE
 RESPONSIBLE FOR THE PERMITTING AND INSTALLATION OF THE
 STREET TREES AND RIGHT OF WAY LANDSCAPING AND
 IRRIGATION APPROVED WITH THIS PETITION.
 3. THE APPLICANT, SUCCESSORS AND ASSIGNS SHALL BE
 RESPONSIBLE FOR THE MAINTENANCE OF THE STREET TREES AND
 RIGHT OF WAY LANDSCAPING AND IRRIGATION. THIS WILL BE
 THROUGH A SEPARATE MAINTENANCE AGREEMENT WITH THE CITY.
  

Review Stop L LANDSCAPING
Rev No 2 Status F Date 11-03-2022 Cont ID  
Sent By rcaranci Date 11-03-2022 Time 15:50 Rev Time 0.00
Received By rcaranci Date 11-03-2022 Time 15:50 Sent To  
Notes
2022-11-03 15:50:38FROM: RAY CARANCI, SENIOR LANDSCAPE PLANNER
 561-822-1462
 PROJECT: 410 N ROSEMARY Z22080012
 OCTOBER 3, 2022
 I HAVE REVIEWED THE ABOVE REFERENCED PETITION, AND
 PROVIDE THE FOLLOWING COMMENTS:
  
  
 1. PARTIALLY SATISFIED. SECTION 94-448 (D)(3) REQUIRES
 NATIVE TREES AND PALMS IN GOOD CONDITION TO BE
 PRESERVED ON SITE OR RELOCATED. ANSI A 300 (PART 5)
 STANDARDS SPECIFY EXAMPLES OF SUITABILITY RATINGS OF
 GOOD, MODERATE, OR POOR FOR RELOCATION. PROVIDE AN
 ARBORISTS REPORT RATING THE CONDITION AND RELOCATION
 POTENTIAL FOR THE NATIVE TREES AND PALMS.
 THERE ARE 7 SABAL PALMS THAT ARE FLORIDA NATIVE SPECIES
 INDICATED AS GOOD CONDITION ON THE TREE DISPOSITION
 PLAN AND THE ARBORISTS REPORT. REVISE DISPOSITION PLAN
 AND LIST TO SHOW AS RELOCATE.
 2. PARTIALLY SATISFIED. PROVIDE THE INDIVIDUAL AND
 TOTAL CANOPY MITIGATION DUE FOR ANY PROPOSED REMOVALS.
 TREES PROPOSED TO BE REMOVED WITH A CANOPY DIAMETER OF
 20 FEET OR MORE SHOULD HAVE THE MITIGATION SQUARE
 FOOTAGE CALCULATED BASED ON THE ACTUAL DIAMETER. TREES
 LESS THAN 20 FEET CANOPY DIAMETER AND PALMS SHOULD SHOW
 THE CATEGORY MITIGATION DUE.
 REMOVE MITIGATION DUE FROM SABAL PALMS FOR RELOCATION.
 ALSO, SABAL PALMS ARE CATEGORY 3, AND IF REMOVED WOULD
 REQUIRE 100 SQ FT CANOPY MITIGATION EACH.
 3. MAKE THE FOLLOWING CORRECTIONS TO THE TREE
 DISPOSITION PLAN:
 ??? SATISFIED. BASED ON THE ARBORIST REPORT FINDINGS,
 IDENTIFY TREE #504 SPECIES.
 ??? SATISFIED. TREE #510 IS NOT LOCATED ON THE SUBJECT
 PROPERTY. NEED TO VERIFY IF IT HAS BEEN REMOVED.
  
 4. SATISFIED. PER SECTION 94-442(B)Q. SHOW TREES AND
 PALMS ON THE ADJACENT PROPERTIES WITHIN 10 FEET OF THE
 PROPERTY LINE.
  
 5. PARTIALLY SATISFIED. SHEET A1.4 SHOWS THE DIAGRAMS
 OF THE REQUIRED AND PROVIDED PUBLIC AND PRIVATE OPEN
 SPACE AREAS FOR THE ZONING DISTRICT NWD-8 BUT LACKS THE
 INFORMATION OF THE REQUIRED AND PROVIDED SQUARE FOOTAGE
 AND HOW THE OPEN SPACE TYPES MEET THE REQUIREMENTS. THE
 PUBLIC OPEN SPACE AREAS IDENTIFIED AS COURTYARD DO NOT
 MEET SOME OF THE REQUIREMENTS AS SHOWN. SHOW HOW THE
 STANDARDS FOR THE TYPES OF OPEN SPACE ARE MET FOR
 VEGETATED AREAS AND TREE CANOPY SQUARE FOOTAGE BASED ON
 TABLE IV-8 ON THE LANDSCAPE PLAN. LANDSCAPE PLANS MUST
 MATCH THE ARCHITECTURAL PLANS AND CLEARLY IDENTIFY THE
 OPEN SPACE TYPE THEN DEMONSTRATE HOW THE REQUIREMENTS
 OF THAT TYPE ARE MET.
 11/3/22:
 PROVIDE THE FOLLOWING:
 PUBLIC OPEN SPACE
 ??? OPEN SPACE SHEET A1.4- LABEL EACH OF THE 4 AREAS
 SHOWN AS COURTYARD.
 ??? OPEN SPACE SHEET A1.4-SHOW THE TOTAL REQUIRED AND
 TOTAL PROVIDED SQUARE FOOTAGE FOR PUBLIC OPEN SPACE
 MATCHING SHEET A0.2
 ??? PROVIDE THE TREE SPECIES AND QUANTITIES COUNTED
 TOWARD TREE CANOPY PROVIDED FOR EACH COURTYARD SPACE ON
 SHEET L-1
 SEMI-PUBLIC OPEN SPACE
 ??? OPEN SPACE SHEET A1.4-SHOW THE AREA COUNTED TOWARD
 WALK UP GARDEN AND SHOW THE VEGETATED AREA PROVIDED
 WITHIN THAT TO MEET THE 40% REQUIREMENT.
 ??? SHOW THE REQUIRED 7 FOOT DEPTH ON THE DIAGRAM.
 PRIVATE OPEN SPACE
 ??? OPEN SPACE SHEET A1.4- SHOW THE AREA COUNTED AND
 LABEL THE TYPE OF OPEN SPACE
 ??? SHOW THE VEGETATED AREA COUNTED TO MEET THE
 REQUIREMENT
 ??? PROVIDE THE TREE SPECIES AND QUANTITIES COUNTED
 TOWARD TREE CANOPY PROVIDED FOR EACH PRIVATE OPEN SPACE
 ON SHEET L-1
  
  
 6. SATISFIED. SITE PLAN SHEET A1.0 DOES NOT MATCH THE
 LANDSCAPE PLAN.
  
 7. NOT SATISFIED. IDENTIFY RELOCATED TREES OR PALMS ON
 THE PLANT LIST AND COUNT THEM TOWARD THE REQUIRED TREES
 IF THEY ARE TO BE USED ON SITE.
 SEE COMMENTS #1 AND #2.
  
  
 8. PARTIALLY SATISFIED. PROVIDE CALCULATIONS FOR
 REQUIRED STREET TREES AT MAXIMUM SPACING EVERY 30 FEET
 OR PORTION THEREOF FOR EACH STREETSCAPE LENGTH, AND
 SHOW THE NUMBER PROVIDED PER SECTION 94-113 AND 94-116
 FOR THE PROPOSED 4TH STREET ADJACENT TO THE SITE.
 DISREGARD 94-116 REFERENCE. SHOW THE CALCULATIONS FOR
 THE STREET TREE REQUIREMENT FOR EACH SIDE OF THE
 PROPOSED 4TH ST. IN THE STREET TREE REQUIREMENT CHART.
  
 9. PARTIALLY SATISFIED. PROVIDE THE REQUIRED 4 FOOT
 WIDE PLANTING STRIP ALONG THE CURB FOR ALL STREETSCAPE
 SECTIONS AND PROVIDE A DETAIL AND SHOW THE LOCATIONS OF
 THE REQUIRED STRUCTURAL SOIL UNDER THE ADJACENT
 SIDEWALK OR HARDSCAPE AREAS.
 PROVIDE A SEPARATE EXHIBIT SHOWING THE LOCATIONS OF
 STRUCTURAL SOIL CLEARLY.
  
  
 10. PARTIALLY SATISFIED. SHOW THE REQUIRED LANDSCAPE
 BUFFERS INSIDE ALL NON RIGHT OF WAY PROPERTY LINES ON
 THE LANDSCAPE AND SITE PLAN. BUFFER OF 5 FEET IS
 REQUIRED ON THE EAST SIDE OF THE SOUTH BUILDING AND AT
 THE NORTH PROPERTY LINE WITH THE TREES SPACED AT 30
 FOOT INTERVALS. ADDRESS HOW THE STREETSCAPE WILL BE
 PLACED INSTEAD OF THE LANDSCAPE BUFFER THAT WOULD BE
 REQUIRED FOR THE PROPOSED 4TH ST.
 LANDSCAPING PROPOSED MEETS THE REQUIREMENTS, BUT
 CONFLICTS WITH PROPOSED DRAINAGE LINES WOULD PREVENT
 INSTALLATION.
  
 11. PARTIALLY SATISFIED. PROVIDE DETAIL ON HOW
 IMPROVEMENTS FOR THE PROPOSED 4TH STREET WILL BE
 INSTALLED ON THE ADJACENT PROPERTY, MODIFYING WHAT IS
 REQUIRED FOR THAT PROPERTY INCLUDING THE BUFFER AND
 STREETSCAPE REQUIREMENTS.
 STAFF NEEDS TO KNOW WHEN THE DESIGNED IMPROVEMENTS WILL
 BE INSTALLED AND WHO WILL MAINTAIN THEM.
  
 12. PARTIALLY SATISFIED. ARTIFICIAL TURF AREAS PROPOSED
 MUST MEET THE REQUIREMENTS OF SECTION 94-451, INCLUDING
 ALL AREAS THAT ARE ALLOWED BY CODE MUST NOT BE VISIBLE
 FROM A ROAD OR STREET. ARTIFICIAL TURF CANNOT BE PLACED
 IN REQUIRED LANDSCAPE AREAS.
 THERE MUST BE A FENCE OR OTHER MEANS OF SCREENING
 INDICATED FOR THE ARTIFICIAL TURF AREA SO IT IS NOT
 VISIBLE FROM THE ROAD OR STREET. ARTIFICIAL TURF CANNOT
 DISPLACE REQUIRED LANDSCAPING IN THE 5 FOOT LANDSCAPE
 BUFFER.
  
  
 13. PARTIALLY SATISFIED. THE EXISTING FPL TRANSMISSION
 LINES ALONG ROSEMARY AVE. WILL BE REMOVED AND PLACED
 UNDERGROUND IN THE FUTURE AND THE STREETSCAPE DESIGNED.
 THE APPLICANT IS REQUIRED TO INSTALL AND MAINTAIN THE
 STREETSCAPE SO A PLAN MUST BE DEVELOPED THAT ACCOUNTS
 FOR THE FUTURE DESIGN OF THE STREETSCAPE.
 PER STAFF AND THE CRA, STREETSCAPE IS TO BE PROPOSED
 THAT MEETS THE CURRENT CODE REQUIREMENTS ON ROSEMARY
 AVE. TREES ARE TO BE LIVE OAKS MEETING THE 20 FOOT
 HEIGHT REQUIREMENT WITH THE 4 FOOT WIDTH PLANTING STRIP
 ADJACENT TO THE CURB.
  
 14. PARTIALLY SATISFIED. SHOW ALL EXISTING AND PROPOSED
 WATER AND SEWER AND DRAINAGE LINES ON THE LANDSCAPE
 PLAN. SHOW LOCATIONS OF BACKFLOWS AND ADJUST LOCATIONS
 OF UTILITY LINES TO RESOLVE CONFLICTS WITH EXISTING AND
 PROPOSED TREES AND LANDSCAPING.
 DRAINAGE LINES AND EXFILTRATION TRENCHES LOCATED ALONG
 THE NORTH AND EAST BUFFER ARE IN CONFLICT WITH REQUIRED
 LANDSCAPING AND MUST BE PLACED IN A DIFFERENT LOCATION.
  
 15. SATISFIED. SHOW COMPLIANCE WITH SECTION 94-445 L.
 PLANT SPECIES. A MINIMUM OF 60 PERCENT OF PLANT
 MATERIAL ADDED SHALL BE FLORIDA NATIVE OR DROUGHT
 TOLERANT SPECIES SELECTED FROM THE CITY LIST OR THE
 LIST OF SPECIES IN THE MOST RECENT EDITION OF SOUTH
 FLORIDA WATER MANAGEMENT DISTRICT WATERWISE SOUTH
 FLORIDA LANDSCAPES. PROVIDE THE ACTUAL PERCENTAGE BASED
 ON THE PLANT LIST.
  
 16. SATISFIED. PROVIDE SCREENING HEDGES FOR ALL GROUND
 MOUNTED VALVES AND EQUIPMENT AND ADD A NOTE THAT ALL
 EQUIPMENT WILL BE SCREENED.
  
 ADDITIONAL COMMENTS 11/3/22:
  
 17. THE AUSTRALIAN PINE 515D MAY BE INDICATED AS TO BE
 REMOVED FROM THE ADJACENT CITY OWNED PARCEL. THIS IS A
 PROHIBITED INVASIVE EXOTIC SPECIES AND MAY BE A SAFETY
 PROBLEM DURING FUTURE CONSTRUCTION DUE TO ITS SIZE AND
 PROXIMITY TO THE PROPERTY LINE.
  
 18. REVISE THE FLORIDA FRIENDLY POINTS CHART TO ADD 5
 POINTS TO ACHIEVE THE REQUIRED 50 POINTS.
 CONDITIONS OF APPROVAL
 1. PRIOR TO THE REMOVAL OR RELOCATION OF ANY TREES ON
 THE PROPERTY, A TREE ALTERATION PERMIT SHALL BE
 SUBMITTED, REVIEWED AND APPROVED BY THE DEVELOPMENT
 SERVICES DEPARTMENT, PLANNING DIVISION.
 2. THE APPLICANT, SUCCESSORS AND ASSIGNS SHALL BE
 RESPONSIBLE FOR THE PERMITTING AND INSTALLATION OF THE
 STREET TREES AND RIGHT OF WAY LANDSCAPING AND
 IRRIGATION APPROVED WITH THIS PETITION.
 3. THE APPLICANT, SUCCESSORS AND ASSIGNS SHALL BE
 RESPONSIBLE FOR THE MAINTENANCE OF THE STREET TREES AND
 RIGHT OF WAY LANDSCAPING AND IRRIGATION. THIS WILL BE
 THROUGH A SEPARATE MAINTENANCE AGREEMENT WITH THE CITY.
  

Review Stop L LANDSCAPING
Rev No 1 Status F Date 09-06-2022 Cont ID  
Sent By rcaranci Date 09-06-2022 Time 12:44 Rev Time 0.00
Received By rcaranci Date 09-06-2022 Time 12:43 Sent To  
Notes
2022-09-06 12:45:26FROM: RAY CARANCI, SENIOR LANDSCAPE PLANNER
 561-822-1462
 PROJECT: 410 N ROSEMARY Z22080012
 SEPTEMBER 6, 2022
 I HAVE REVIEWED THE ABOVE REFERENCED PETITION, AND
 PROVIDE THE FOLLOWING COMMENTS:
  
  
 1. SECTION 94-448 (D)(3) REQUIRES NATIVE TREES AND
 PALMS IN GOOD CONDITION TO BE PRESERVED ON SITE OR
 RELOCATED. ANSI A 300 (PART 5) STANDARDS SPECIFY
 EXAMPLES OF SUITABILITY RATINGS OF GOOD, MODERATE, OR
 POOR FOR RELOCATION. PROVIDE AN ARBORISTS REPORT RATING
 THE CONDITION AND RELOCATION POTENTIAL FOR THE NATIVE
 TREES AND PALMS.
 2. PROVIDE THE INDIVIDUAL AND TOTAL CANOPY MITIGATION
 DUE FOR ANY PROPOSED REMOVALS. TREES PROPOSED TO BE
 REMOVED WITH A CANOPY DIAMETER OF 20 FEET OR MORE
 SHOULD HAVE THE MITIGATION SQUARE FOOTAGE CALCULATED
 BASED ON THE ACTUAL DIAMETER. TREES LESS THAN 20 FEET
 CANOPY DIAMETER AND PALMS SHOULD SHOW THE CATEGORY
 MITIGATION DUE.
 3. MAKE THE FOLLOWING CORRECTIONS TO THE TREE
 DISPOSITION PLAN:
 ? BASED ON THE ARBORIST REPORT FINDINGS, IDENTIFY TREE
 #504 SPECIES.
 ? TREE #510 IS NOT LOCATED ON THE SUBJECT PROPERTY.
 NEED TO VERIFY IF IT HAS BEEN REMOVED.
  
 4. PER SECTION 94-442(B)Q. SHOW TREES AND PALMS ON THE
 ADJACENT PROPERTIES WITHIN 10 FEET OF THE PROPERTY
 LINE.
  
 5. SHEET A1.4 SHOWS THE DIAGRAMS OF THE REQUIRED AND
 PROVIDED PUBLIC AND PRIVATE OPEN SPACE AREAS FOR THE
 ZONING DISTRICT NWD-8 BUT LACKS THE INFORMATION OF THE
 REQUIRED AND PROVIDED SQUARE FOOTAGE AND HOW THE OPEN
 SPACE TYPES MEET THE REQUIREMENTS. THE PUBLIC OPEN
 SPACE AREAS IDENTIFIED AS COURTYARD DO NOT MEET SOME OF
 THE REQUIREMENTS AS SHOWN. SHOW HOW THE STANDARDS FOR
 THE TYPES OF OPEN SPACE ARE MET FOR VEGETATED AREAS AND
 TREE CANOPY SQUARE FOOTAGE BASED ON TABLE IV-8 ON THE
 LANDSCAPE PLAN. LANDSCAPE PLANS MUST MATCH THE
 ARCHITECTURAL PLANS AND CLEARLY IDENTIFY THE OPEN SPACE
 TYPE THEN DEMONSTRATE HOW THE REQUIREMENTS OF THAT TYPE
 ARE MET.
  
 6. SITE PLAN SHEET A1.0 DOES NOT MATCH THE LANDSCAPE
 PLAN FOR THE
  
 7. IDENTIFY RELOCATED TREES OR PALMS ON THE PLANT LIST
 AND COUNT THEM TOWARD THE REQUIRED TREES IF THEY ARE TO
 BE USED ON SITE.
  
 8. PROVIDE CALCULATIONS FOR REQUIRED STREET TREES AT
 MAXIMUM SPACING EVERY 30 FEET OR PORTION THEREOF FOR
 EACH STREETSCAPE LENGTH, AND SHOW THE NUMBER PROVIDED
 PER SECTION 94-113 AND 94-116 FOR THE PROPOSED 4TH
 STREET ADJACENT TO THE SITE.
  
 9. PROVIDE THE REQUIRED 4 FOOT WIDE PLANTING STRIP
 ALONG THE CURB FOR ALL STREETSCAPE SECTIONS AND PROVIDE
 A DETAIL AND SHOW THE LOCATIONS OF THE REQUIRED
 STRUCTURAL SOIL UNDER THE ADJACENT SIDEWALK OR
 HARDSCAPE AREAS.
  
 10. SHOW THE REQUIRED LANDSCAPE BUFFERS INSIDE ALL NON
 RIGHT OF WAY PROPERTY LINES ON THE LANDSCAPE AND SITE
 PLAN. BUFFER OF 5 FEET IS REQUIRED ON THE EAST SIDE OF
 THE SOUTH BUILDING AND AT THE NORTH PROPERTY LINE WITH
 THE TREES SPACED AT 30 FOOT INTERVALS. ADDRESS HOW THE
 STREETSCAPE WILL BE PLACED INSTEAD OF THE LANDSCAPE
 BUFFER THAT WOULD BE REQUIRED FOR THE PROPOSED 4TH ST.
  
 11. PROVIDE DETAIL ON HOW IMPROVEMENTS FOR THE PROPOSED
 4TH STREET WILL BE INSTALLED ON THE ADJACENT PROPERTY,
 MODIFYING WHAT IS REQUIRED FOR THAT PROPERTY INCLUDING
 THE BUFFER AND STREETSCAPE REQUIREMENTS.
  
 12. ARTIFICIAL TURF AREAS PROPOSED MUST MEET THE
 REQUIREMENTS OF SECTION 94-451, INCLUDING ALL AREAS
 THAT ARE ALLOWED BY CODE MUST NOT BE VISIBLE FROM A
 ROAD OR STREET. ARTIFICIAL TURF CANNOT BE PLACED IN
 REQUIRED LANDSCAPE AREAS.
  
 13. THE EXISTING FPL TRANSMISSION LINES ALONG ROSEMARY
 AVE. WILL BE REMOVED AND PLACED UNDERGROUND IN THE
 FUTURE AND THE STREETSCAPE DESIGNED. THE APPLICANT IS
 REQUIRED TO INSTALL AND MAINTAIN THE STREETSCAPE SO A
 PLAN MUST BE DEVELOPED THAT ACCOUNTS FOR THE FUTURE
 DESIGN OF THE STREETSCAPE.
  
 14. SHOW ALL EXISTING AND PROPOSED WATER AND SEWER AND
 DRAINAGE LINES ON THE LANDSCAPE PLAN. SHOW LOCATIONS OF
 BACKFLOWS AND ADJUST LOCATIONS OF UTILITY LINES TO
 RESOLVE CONFLICTS WITH EXISTING AND PROPOSED TREES AND
 LANDSCAPING.
  
 15. SHOW COMPLIANCE WITH SECTION 94-445 L. PLANT
 SPECIES. A MINIMUM OF 60 PERCENT OF PLANT MATERIAL
 ADDED SHALL BE FLORIDA NATIVE OR DROUGHT TOLERANT
 SPECIES SELECTED FROM THE CITY LIST OR THE LIST OF
 SPECIES IN THE MOST RECENT EDITION OF SOUTH FLORIDA
 WATER MANAGEMENT DISTRICT WATERWISE SOUTH FLORIDA
 LANDSCAPES. PROVIDE THE ACTUAL PERCENTAGE BASED ON THE
 PLANT LIST.
  
 16. PROVIDE SCREENING HEDGES FOR ALL GROUND MOUNTED
 VALVES AND EQUIPMENT AND ADD A NOTE THAT ALL EQUIPMENT
 WILL BE SCREENED.
  
  
  
  
  
  
 CONDITIONS OF APPROVAL
 1. PRIOR TO THE REMOVAL OR RELOCATION OF ANY TREES ON
 THE PROPERTY, A TREE ALTERATION PERMIT SHALL BE
 SUBMITTED, REVIEWED AND APPROVED BY THE DEVELOPMENT
 SERVICES DEPARTMENT, PLANNING DIVISION.
 2. THE APPLICANT, SUCCESSORS AND ASSIGNS SHALL BE
 RESPONSIBLE FOR THE PERMITTING AND INSTALLATION OF THE
 STREET TREES AND RIGHT OF WAY LANDSCAPING AND
 IRRIGATION APPROVED WITH THIS PETITION.
 3. THE APPLICANT, SUCCESSORS AND ASSIGNS SHALL BE
 RESPONSIBLE FOR THE MAINTENANCE OF THE STREET TREES AND
 RIGHT OF WAY LANDSCAPING AND IRRIGATION. THIS WILL BE
 THROUGH A SEPARATE MAINTENANCE AGREEMENT WITH THE CITY.
  

Review Stop PU PUBLIC UTILITIES
Rev No 3 Status P Date 03-15-2023 Cont ID  
Sent By relizond Date 03-15-2023 Time 13:18 Rev Time 0.00
Received By relizond Date 03-15-2023 Time 12:50 Sent To  
Notes
2023-03-15 13:17:58CONDITIONS OF APPROVAL (WILL BE REQUIRED TO ADDRESS
 DURING ENGINEERING REVIEW)
  
 PROVIDE CALCULATIONS ON PLANS OF EXISTING AND PROPOSED
 CONDITIONS FOR WATER AND SEWER
 ALL INSTALLED WATER MAIN MUST BE DIP PER CITY
 STANDARDS
 DOUBLE VALVING AND JUMPER ASSEMBLY WILL BE NECESSARY
 FOR TIE-INS TO EXISTING WATER MAIN FOR PIGGING AND
 FLUSHING TESTING PER CITY DETAIL P-6
 LABEL ALL FITTING THAT ARE TO BE INSTALLED
 INCLUDE ALL DRY UTILITIES ON THE PLANS, INCLUDING THOSE
 PROPOSED FOR INSTALLATION
 PROFILE 4 SHOWS PROPOSED WATER MAIN TO ONLY BE 9.5
 INCHES ABOVE EXISTING 30" SEWER MAIN
 HAVE AN EMERGENCY PREPAREDNESS PLAN IN THE EVENT OF THE
 30" SEWER MAIN COLLAPSING DURING CONSTRUCTION
  
 MORE COMMENTS PENDING REVISIONS ON NEXT SUBMITTAL
  
 RICKY ELIZONDO
 [email protected]
  

Review Stop PU PUBLIC UTILITIES
Rev No 2 Status F Date 01-24-2023 Cont ID  
Sent By relizond Date 01-24-2023 Time 10:21 Rev Time 0.00
Received By relizond Date 01-24-2023 Time 10:22 Sent To  
Notes
2023-01-24 10:21:44-MANHOLES WITH LATERALS BEING CORED INTO THEM WILL
 REQUIRE REHABBING
 -DENOTE ANY AND ALL WATER SERVICES THAT ARE TO BE
 REMOVED AND CAPPED AT MAIN
 -PROVIDE CALCULATIONS ON PLANS OF EXISTING AND PROPOSED
 CONDITIONS FOR WATER AND SEWER
 -ALL INSTALLED WATER MAIN MUST BE DIP PER CITY
 STANDARDS
 -DOUBLE VALVING AND JUMPER ASSEMBLY WILL BE NECESSARY
 FOR TIE-INS TO EXISTING WATER MAIN FOR PIGGING AND
 FLUSHING TESTING PER CITY DETAIL P-6
 -LABEL ALL FITTING THAT ARE TO BE INSTALLED
 -INCLUDE ALL DRY UTILITIES ON THE PLANS, INCLUDING
 THOSE PROPOSED FOR INSTALLATION
 -PROFILE 4 SHOWS PROPOSED WATER MAIN TO ONLY BE 9.5
 INCHES ABOVE EXISTING 30" SEWER MAIN
 -HAVE AN EMERGENCY PREPAREDNESS PLAN IN THE EVENT OF
 THE 30" SEWER MAIN COLLAPSING DURING CONSTRUCTION
  
 RICKY ELIZONDO [email protected]
  
  
  

Review Stop PU PUBLIC UTILITIES
Rev No 1 Status F Date 09-07-2022 Cont ID  
Sent By mtechnow Date 09-07-2022 Time 16:55 Rev Time 0.00
Received By mtechnow Date 09-07-2022 Time 16:28 Sent To  
Notes
2022-09-07 16:55:54-CALL FOR MANHOLE TO BE INSTALLED AT JUNCTION OF
 PROPOSSED SANITARY LATERAL AND 30" GRAVITY MAIN PER
 HEALTH DEPT STANDARDS.
 -UPSIZE THE EXISITNG 8" WM ON ROSEMARY TO 12" WITHIN
 PROJECT LIMITS (3RD ST TO 5TH ST).
 -UPSIZE THE EXISTING 8" WM ON W RAILROAD AVE TO 10"
 WITHIN PROJECT LIMIT. (3RD ST. TO 5TH ST.)
 -FOR ENG SUBMITTAL PROVIDE LOS CALCULATIONS AND FIRE
 FLOW CALCS ON PLAN SHEET.
  
 MICHAEL TECHNOW [email protected]

Review Stop PU-CS PUBLIC UTILITIES CUSTOMER SRVC
Rev No 3 Status P Date 01-06-2023 Cont ID  
Sent By mhurley Date 01-06-2023 Time 07:26 Rev Time 0.00
Received By mhurley Date   Time   Sent To  
Notes
2023-01-06 07:26:04-ATTEMPT TO ATTAIN CLOSER TO 5 FEET HORIZONTAL
 CLEARANCE BETWEEN NORTHWEST SEWER LATERAL AND TREE
 TRUNK.
 -AT ENGINEERING DEVELOPMENT SUBMITTAL, CORRECT LEADER
 LINES FOR UTILITY EASEMENTS.
 -WATER SERVICES WILL NEED REVISION AT ENGINEERING
 DEVELOPMENT SUBMITTAL. SEE PRIOR REVIEW COMMENTS
 CONCERNING PIPE SIZING.
 RESPECTFULLY,
 MARK HURLEY [email protected]

Review Stop PU-CS PUBLIC UTILITIES CUSTOMER SRVC
Rev No 2 Status F Date 10-24-2022 Cont ID  
Sent By mhurley Date 10-24-2022 Time 14:04 Rev Time 0.00
Received By mhurley Date   Time   Sent To  
Notes
2022-10-24 14:04:13PLEASE PROVIDE WRITTEN RESPONSES TO THE FOLLOWING:
 -C900 CANNOT BE USED FOR THE WATER MAINS AND LARGE
 WATER SERVICES. SWITCH TO DIP.
 -ADJUST BOUNDARIES OF PROPOSED UTILITY EASEMENTS SO
 THEY DO NOT INCLUDE THE DCDA FIRELINE BACKFLOW
 ASSEMBLIES.
 -4 INCH WATERMETER SHOULD HAVE 4 INCH PIPE FROM METER
 TO WATER MAIN.
 -6 INCH WATER METER SHOULD HAVE 6 INCH PIPE AND
 FITTINGS INSTEAD OF 4 INCH.
 -ADD PROFILE OF ENTIRE PROPOSE WATER MAIN WITH
 SUBMITTAL PACKAGE AT ENGINEERING DEVELOPMENT SUBMITTAL.
 -LANDSCAPE PLAN SEEMS TO SHOW TREES IN THE MIDDLE OF
 SIDEWALK AT THE SOUTHWEST AREA OF 4TH ST. IS THAT
 INTENTIONAL AND WILL IT IMPEDE PEDESTRIAN OR ADA
 MOVEMENT?
 -ALSO ON LANDSCAPE PLAN DISTANCE BETWEEN TREE TRUNK AND
 SEWER CLEANOUT NEAR THE NORTHWEST SIDE LOOKS TOO CLOSE.
 IF UNDER 5 FEET NEED MORE HORIZTONAL CLEARANCE
 DISTANCE.
 RESPECTFULLY,
 MARK HURLEY [email protected]

Review Stop PU-CS PUBLIC UTILITIES CUSTOMER SRVC
Rev No 1 Status F Date 09-03-2022 Cont ID  
Sent By mhurley Date 09-03-2022 Time 08:41 Rev Time 0.00
Received By mhurley Date   Time   Sent To  
Notes
2022-09-03 08:41:42PLEASE PROVIDE WRITTEN RESPONSES TO THE FOLLOWING:
 -DOMESTIC 8 INCH METER WOULD NEED TO BE ABOVE-GROUND
 REFERENCING STANDARD DETAIL WS3. ADD WORDING
 ABOVE-GROUND TO LABEL ALONG WITH STANDARD DETAIL
 REFERENCE.
 -PROPOSED 8 INCH METER CANNOT BE OBSTRUCTED BY
 BUILDING, WALL, OR FENCE AND MUST BE NO GREATER THAN 15
 FEET FROM STREET TO ALLOW REPLACEMENT WITH CITY CRANE
 TRUCK.
 -CITY DOES NOT STOCK 8 INCH METERS AND WOULD HAVE TO BE
 ORDERED AFTER FORMAL QUOTE IS PAID AND UTILITY BILLING
 ACCOUNTS SETUP. MAY EXPERIENCE LONG LEAD TIMES TILL
 METER IS RECEIVED AFTER ORDER, AND PROJECT SHOULD ALSO
 ANTICIPATE THE DELAY BETWEEN WATER SERVICE BUILDOUT AND
 METER INSTALLATION.
 -ADD SYMBOL FOR WATER METER ON LEGEND AND SHOW THEM ON
 PLANS. RECOMMEND SHOWING METERS AT MORE REALISTIC SCALE
 AS THE LARGER METERS AND BACKFLOWS CAN HAVE INCREASED
 FOOTPRINT.
 -SHEET C5. PROPOSED FIRELINE CANNOT BE UNDER OR NEAR
 EXISTING TRAFFIC SIGNAL POLE.
 -ENSURE THAT PROPOSED FIRELINE BACKFLOW ASSEMBLY
 LOCATIONS ARE NFPA COMPLIANT.
 -SHEET C7 SHOWS EXISTING UTILITY POLE AND GUY WIRE IN
 MIDDLE OF PROPOSED DRIVEWAY.
 -SHEET C6: FAR NORTHEAST DRIVEWAY FLARE SEEMS TO BE
 EXTENDING ONTO NEIGHBORING PROPERTY; EXISTING LIGHT
 POLE IN PROPOSED DRIVEWAY ON EAST SIDE; DIGITAL SIGN
 AND SEAL NOT READABLE.
 -IF FDC ARE NEEDED OR REQUIRED, SHOW AND LABEL ON PLANS
 AND ENSURE ACCEPTABLE DISTANCE FROM FIRE HYDRANT.
 -SHEET C6. NORTHWEST DOMESTIC WATER SERVICE SHOWS
 CONFLICT WITH SOME KIND OF UTILITY IN SIDEWALK.
 -ENGINEERING PLANS AND SURVEY SHOW GAS MARKER ON WEST
 SIDE OF PROJECT. HISTORIC PICTURES ALSO SHOW GAS LINE
 LOCATES. SHOW BETTER ALL EXISTING GAS UTILITIES, AND IF
 REMAINING ENSURE NO CONFLICT BETWEEN PROJECT AND GAS
 UTILITIES.
 -CALLOUT PROPOSED SANITARY SEWER MANHOLES AND
 CLEANOUTS.
 -SUBMIT SEPARATE LANDSCAPING SHEET THAT SHOWS ALL TREES
 AND UTILITIES. ENSURE THAT UTILITIES AND TREES HAVE
 APPROPRIATE CLEARANCE DISTANCE.
 -CONSIDER PARALLEL/DUAL DOMESTIC BACKFLOW ASSEMBLIES TO
 MINIMIZE WATER OUTAGES DURING BACKFLOW MAINTENANCE.
 -VERIFY PRIVATE FIRE SYSTEM WILL NOT HAVE ANY AUXILIARY
 WATER SUPPLIES CONNECTED TO IT SUCH AS WELLS.
 -WILL ACCESS EASEMENT INCLUDE USE OF BRIDGE AND
 TERRACES?
 -A2.1 SHOWS PROPOSED 4TH ST ALLEY AS ONE WAY. ON C7 ARE
 ANY ONE WAY OR DO NOT ENTER SIGNS NEEDED?
 -ON PGD PLAN NEAR THE NORTH PROPERTY LINE, IS THE AREA
 NEAR THE GENERATOR AND FPL ROOM DOORS CONCRETE? IF SO,
 ADD CORRECT CONCRETE SHADING.
 -A5.1 SHOWS AREA OF PROPOSED SOUTHWEST FIRELINE
 BACKFLOW ASSEMBLY TO BE ELEVATED. CITY UTILITY WORKERS
 MUST HAVE SAFE AND EASY ACCESS TO ALL WATER METERS
 INCLUDING FIRELINE DETECTOR METERS. ON WATER PLAN ADD
 SPOT ELEVATIONS AROUND THAT AREA SHOWING HEIGHT
 DIFFERENCE.
 -ADD WATER AND SEWER DEMAND CALCULATIONS TO SHEET C6.
 RESPECTFULLY,
 MARK HURLEY [email protected]

Review Stop PW PUBLIC WORKS
Rev No 4 Status P Date 03-15-2023 Cont ID  
Sent By   Date 03-15-2023 Time   Rev Time 0.00
Received By   Date 03-15-2023 Time   Sent To  
Notes
2023-02-27 14:40:03NO FURTHER COMMENTS.
  
 MATT HEJAZI
 DEPT. OF PUBLIC WORKS
 [email protected]

Review Stop PW PUBLIC WORKS
Rev No 3 Status F Date 01-12-2023 Cont ID  
Sent By   Date 01-12-2023 Time   Rev Time 0.00
Received By   Date 01-12-2023 Time   Sent To  
Notes
2023-01-12 10:05:14IF THE INDOOR STAGING AREA DOES NOT MEET THE MINIMUM
 HEIGHT CLEARANCE OF 21 FT, THE TRASH CONTAINERS SHALL
 BE ROLLED OUT BY THE CURBSIDE ON THE SERVICE DAYS. THE
 SITE PLAN SHOULD REFLECT THE STAGING AREA FOR THE
 CONTAINERS, WHICH HAS TO BE APPROVED BY PUBLIC WORKS.
  
  
 MATT HEJAZI
 DEPT. OF PUBLIC WORKS
 [email protected]
 561-822-2045

Review Stop PW PUBLIC WORKS
Rev No 2 Status P Date 10-20-2022 Cont ID  
Sent By   Date 10-20-2022 Time   Rev Time 0.00
Received By   Date 10-20-2022 Time   Sent To  
Notes
2022-10-20 15:45:40CONDITIONS OF APPROVAL:
 1- THE TRASH CONTAINERS SHALL BE FRONT LOAD TYPE.
 2- THE TRASH CONTAINERS SHALL BE ROLLED OUT BY THE
 CURBSIDE ON THE SERVICE DAYS. THE SITE PLAN SHOULD
 REFLECT THE STAGING AREA FOR THE CONTAINERS, WHICH HAS
 TO BE APPROVED BY PUBLIC WORKS.
  
 MATT HEJAZI
 DEPT. OF PUBLIC WORKS
 [email protected]
 561-822-2045

Review Stop PW PUBLIC WORKS
Rev No 1 Status F Date 08-23-2022 Cont ID  
Sent By   Date 08-23-2022 Time   Rev Time 0.00
Received By   Date 08-23-2022 Time   Sent To  
Notes
2022-08-23 10:40:10 
 PLEASE PROVIDE THE FOLLOWINGS:
 1- LOS (LEVEL OF SERVICE ANALYSIS) TO REFLECT THE SOLID
 WASTE VOLUME PRODUCED ALONG WITH THE SIZE, TYPE AND
 QUANTITY OF THE CONTAINER (I.E. DUMPSTER/COMPACTOR)
 THAT WILL BE UTILIZED FOR THE SANITATION SERVICE.
 2- DETAILS FOR SANITATION SERVICE (I.E. SOLID WASTE
 CONTAINER(S) TYPE, COLLECTION LOCATION, ETC.). FOR A
 FREESTANDING SITE DUMPSTER ENCLOSURE, THE ENCLOSURE
 SHALL COMPLY WITH THE LATEST REVISION OF CITY OF WEST
 PALM BEACH GENERAL CONSTRUCTION-GARBAGE ENCLOSURE
 STANDARD, GC-7. (LINK TO THE LATEST REVISION OF THE
 GC-7 DOCUMENT: HTTPS://WWW.WPB.ORG/HOME/SHOWPUBLISHEDDO
 CUMENT/3690/637629060422100000)
 3- AUTOTURN EXHIBIT (DYNAMIC ENVELOPE AND THE VEHICLE?S
 WHEEL PATH) FOR THE SANITATION SERVICE, FRONT LOADER
 TRUCK WITH THE FOLLOWING SPECS:
 - DUAL AXLES
 - TRUCK LENGTH: 35 FT
 - TRUCK WIDTH: 11 FT
 - TURNING RADIUS:
 - SAE TURNING RADIUS: 32.5 FT
 - CURB-TO-CURB DIAMETER: 74 FT
 - WALL-TO-WALL DIAMETER: 86.3 FT
 4- DESIGNATED LOCATION FOR THE BULK ITEM PICK UP AND
 RECYCLING CONTAINERS
 5- OWNERS AND/OR OCCUPANTS OF PROPERTY THAT REQUIRE
 GREASE HAULING SERVICES SHALL ENSURE THAT THEIR GREASE
 TANKS OR CONTAINERS REMAIN CLEAN, AND ARE ENCLOSED AND
 NOT IN PUBLIC VIEW.
 6- IN CASE OF PROPOSING ADDITION OF ANY NEW CAN(S) IN
 THE CITY`S RIGHT-OF-WAY , THE LOCATION AND QUANTITY OF
 THE CAN(S) SHALL BE REVIEWED AND APPROVED BY PUBLIC
 WORKS DEPARTMENT AND THE CAN(S) SHALL BE TYPE, SIZE AND
 COLOR APPROVED BY PUBLIC WORKS DEPARTMENT. THE BUILDING
 MAINTENANCE IS RESPONSIBLE TO MAINTAIN AND SERVICE THE
 CAN(S).
 7- ALL THE PARKING STALL PAINTING SHALL COMPLY WITH THE
 CITY`S MUNICIPAL CODE SECTION 94-485 AND FLORIDA
 STATUES [553.5041 F.S.].
 8- SIGNAGE PLAN. ALL STRIPING AND SIGNAGE SHALL COMPLY
 WITH THE LATEST CITY OF WEST PALM BEACH STANDARD
 DETAILS AND MEET THE M.U.T.C.D. LATEST EDITION.
 9- ALL PAVEMENT MARKING , SIGNING AND SIDEWALK DAMAGED
 DURING CONSTRUCTION SHALL BE RESTORED.
  
  
  
 MATT HEJAZI
 DEPT. OF PUBLIC WORKS
 [email protected]
 561-822-2045
  

Review Stop STORM STORMWATER
Rev No 3 Status P Date 03-15-2023 Cont ID  
Sent By tward Date 03-15-2023 Time 11:30 Rev Time 0.00
Received By tward Date 03-15-2023 Time 11:40 Sent To  
Notes
2023-03-15 11:39:47THE CIVIL PLANS EMAILED TO T. WARD ON 3/14/23 ARE
 SUFFICIENT FOR SITE PLAN APPROVAL WITH THE FOLLOWING
 DEFICIENCIES IDENTIFIED. THESE CAN BE ADDRESSED WITH
 THE ENGINEERING PERMIT SUBMITTAL.
  
 1. EXISTING UTILITIES ARE MISSING FROM THE RIGHT OF WAY
 ON SHEET C-5.
  
 2. RUNOFF IN THE EXFILTRATION TRENCH SYSTEM TO PASS
 OVER A WEIR BEFORE FLOWING THROUGH A BLEEDER.
  
 3. SUGGEST EXTENDING SIDEWALK BEHIND THE PARKWAY ON 3RD
 ST. TO THE EAST SIDE OF THE EAST DRIVEWAY TO 3RD ST.
 THIS WILL SHORTEN THE LANDSCAPE AREA ALONG THE EAST
 PROPERTY LINE.
  
 4. REMOVE OR MOVE THE DRAINAGE OUTFALL PIPE LABEL NECT
 TO STRUCTURE NO. 11.
  
 TRACY WARD, PE
 SENIOR STORMWATER ENGINEER
 ENGINEERING SERVICES DEPARTMENT
 561-494-1120 (O)
 [email protected]

Review Stop STORM STORMWATER
Rev No 2 Status F Date 02-23-2023 Cont ID  
Sent By tward Date 02-23-2023 Time 11:32 Rev Time 0.00
Received By tward Date 02-23-2023 Time 11:42 Sent To  
Notes
2023-02-23 11:39:40THE FOLLOWING COMMENTS ARE FROM THE REVIEW OF THE
 2/17/2023 SUBMITTAL:
  
 1. [NOT SATISFIED] THE CITY'S OFFICIAL VERTICAL DATUM
 IS NGVD1929. THE CITY HAS ALLOWED THE USE OF NAVD1988
 AS LONG AS THE CONVERSION EQUATION TO NGVD1929 AT THE
 PROJECT LOCATION IS PROVIDED. PROVIDE VERTICAL DATUM
 CONVERSION TO NGVD1929 ON THE SURVEYS. SEVERAL OF THE
 SURVEYS LIST NAVD1988 AS THE VERTICAL DATUM BUT THERE
 MAY NOT BE ELEVATION DATA ON THE SURVEYS. EVERY SHEET
 WITH ELEVATION INFORMATION SHOULD LIST THE VERTICAL
 DATUM AND THE CONVERSION EQUATION TO NGVD1929.
  
 2. [NOT SATISFIED] PROVIDE SCALE BAR ON THE
 ARCHITECTURAL PLANS. THE LISTED SCALES (1/8 INCH = 1
 FEET) ON THE FLOOR PLANS (SHEETS A2.2, ETC.) ARE DOUBLE
 THE SCALE OF WHAT IS PRESENTED ON THE DRAWINGS.
  
 3. [SATISFIED] SHOW UTILITIES ON THE LANDSCAPE PLANS.
  
 4. [PARTIALLY SATISFIED] SHOW AND LABEL ALL EXISTING
 UTILITY LINES (SIZE, MATERIAL, TYPE - STORM, SAN., WM,
 ETC.) ON THE ENGINEERING PLANS.
  
 5. [NOT SATISFIED - FENCE SHOULD BE REMOVED] PORTIONS
 OF NORTH AND EAST EXISTING CHAIN LINK FENCING IS ON
 PROPERTY NOT OWNED BY THE APPLICANT.
  
 6. [SATISFIED] PORTION OF PROPOSED NORTH DRIVEWAY APRON
 TO W. RAILROAD AVE WILL BE ON PROPERTY NOT OWNED BY
 APPLICANT.
  
 7. [SATISFIED] PORTION OF ROADWAY, SIDEWALK AND
 DRAINAGE SYSTEM IN THE MIDDLE OF THE DEVELOPMENT IS
 LOCATED ON PROPERTY NOT OWNED BY THE APPLICANT.
  
 8. [NOT SATISFIED] PROPOSED SIDEWALK ON ADJACENT
 PROPERTY TO THE NORTH ALONG W. RAILROAD AVE DOES NOT
 ALIGN WITH THE EXISTING SIDEWALK.
  
 9. [NOT SATISFIED - RESPONSE TO COMMENT NOT FOUND]
 SIDEWALK EASEMENT WILL BE NEEDED FOR THE PROPOSED
 SIDEWALK ALONG THE SOUTH AND EAST PROPERTY LINES AND
 POSSIBLY THE SIDEWALK ENCROACHMENT ON THE WEST PROPERTY
 LINE.
  
 10. [SATISFIED] SHOW SIDEWALK CONNECTION AND CURB RAMP
 TO THE CROSSWALK ON 3RD STREET.
  
 11. [NOT SATISFIED] SIDEWALK EAST OF EAST DRIVEWAY TO
 3RD STREET WILL BE ON PROPERTY NOT OWNED BY THE
 APPLICANT NOR DOES THE PROPOSED SIDEWALK ALIGN WITH THE
 EXISTING SIDEWALK.
  
 12. [NOT SATISFIED] DRIVEWAY APRONS WITHIN THE RIGHT OF
 WAY SHOULD BE CONCRETE.
  
 13. [NOT SATISFIED] DRIVEWAY LOCATIONS WILL AFFECT
 EXISTING DRAINAGE STRUCTURES WITHIN THE RIGHT OF WAY.
  
 14. [NOT SATISFIED] PROVIDE CROSS SECTIONS FOR THE
 FOLLOWING. SHOW, IF APPLICABLE, RIGHT OF WAY LINE,
 STREET NAME, GRADE BREAKS, SURFACE FEATURES, DIMENSIONS
 FROM RIGHT OF WAY TO BACK OF SIDEWALK, FACE OF
 BUILDING, HIGH POINTS OF DRIVEWAYS, BACK OF CURB, ETC.
 A. ALL DRIVEWAY CONNECTIONS TO THE RIGHT OF WAY.
 SECTION TO EXTEND FROM CENTERLINE OF RIGHT OF WAY TO 5
 FEET BEYOND HIGH POINT OF DRIVEWAY.
 B. NORTH-SOUTH SECTION ON THE 4TH STREET DRIVE
 EXTENSION FROM FACE OF BUILDING TO FACE OF BUILDING.
 C. FROM CENTERLINE OF RIGHT OF WAY TO EACH BUILDING
 FACE.
 D. FROM NORTH FACE OF NORTH BUILDING TO THE EXISTING
 PARKING LOT ON THE PROPERTY TO THE NORTH. THE SECTION
 TO BE LOCATED WITHIN THE LONGER NORTH PROPERTY LINE.
  
 15. [NOT SATISFIED] DRAW THE OUTLINE OF THE
 EXFILTRATION TRENCH TO THE DESIGN WIDTH (EXFILTRATION
 TRENCH DETAIL SHOWS 8 FEET WIDE TRENCH) ON THE PLANS.
 FOR THE EXFILTRATION TRENCH ALONG W. RAILROAD AVE., THE
 TRENCH WILL BE THE WIDTH OF THE SIDEWALK AND EXTEND
 FROM THE RIGHT OF WAY LINE TO THE BUILDING FACE. FOR
 THE EXFILTRATION TRENCH ALONG THE EXTENSION OF 4TH
 STREET, THE CENTER OF THE PIPE IS LESS THAN 5 FEET FROM
 THE SOUTH BUILDING. BUILDING FOUNDATIONS WILL NEED TO
 BE DESIGNED SO THAT THE SLAB WILL NOT BE UNDERMINED
 WHEN THE EXFILTRATION TRENCH WILL BE REPLACED WHEN IT
 IS NO LONGER FUNCTIONING AS DESIGNED. ANY SLAB OR TREE
 ROOT BARRIER ADJACENT TO THE TRENCH WILL IMPEDE THE
 FLOW OUT THAT SIDE OF THE TRENCH AND SHOULD BE
 ACCOUNTED FOR IN THE EXFILTRATION TRENCH EQUATION.
  
 16. [NOT SATISFIED - RESPONSE TO COMMENT NOT FOUND]
 CONSIDER THERE WILL BE PROPER VERTICAL CLEARANCE FOR
 MAINTAINING THE DRAINAGE SYSTEM AND REPLACING THE
 EXFILTRATION TRENCH SYSTEM WHEN IT IS NO LONGER
 FUNCTIONING AS DESIGNED WITHIN THE ENCLOSED PARKING
 AREAS OF THE BUILDING.
  
 17. [NOT SATISFIED - RESPONSE TO COMMENT NOT FOUND.]
 CONSIDER LOW IMPACT DEVELOPMENT DRAINAGE SYSTEMS IN
 LIEU OR IN COMBINATION WITH THE EXFILTRATION TRENCH
 SYSTEM.
  
 18. [PARTIALLY SATISFIED - SOME STRUCTURES ARE MISSING
 RIM ELEVATIONS] NUMBER THE DRAINAGE STRUCTURES FOR EASE
 OF REFERENCE. NO DESIGN INFORMATION (RIM, INVERT
 ELEVATIONS) IS PROVIDED.
  
 19. [PARTIALLY SATISFIED - LABEL WAS REMOVED. ADD THE
 LABEL BACK TO THE PGD PLAN AND POINT TO THE RIGHT
 CONNECTION] THE OUTFALL CONNECTION TO CITY DRAINAGE
 SYSTEM APPEARS TO BE MISLABELED. IT IS SHOWN POINTING
 TO THE FIRST NORTH-SOUTH PIPE SOUTH OF THE 4TH STREET
 EXTENSION AND EAST OF THE BUILDING.
  
 20. [PARTIALLY SATISFIED] SIGNING AND PAVEMENT
 MARKINGS:
 A. [NOT SHOWN] STOP BAR AND SIGN NEEDED FOR SERVICE
 DRIVE DRIVEWAY AND GARAGE ACCESS DRIVEWAY TO W.
 RAILROAD AVE.
 B. [NOT SHOWN] STOP BAR AND SIGN NEEDED FOR THE TWO
 DRIVEWAYS TO 3RD STREET.
 C. [SATISFIED] DO NOT ENTER AND ONE-WAY SIGNS AT EAST
 END OF 4TH STREET EXTENSION DRIVE.
 D. [NOT SHOWN] ONE WAY SIGN AT WEST END OF 4TH STREET
 EXTENSION DRIVE.
 E. [NOT SHOWN] SHARED BIKE LANE SIGNS FOR N. ROSEMARY.
 F. [REVIEW COLOR OF CENTERLINE STRIPING] PROVIDE
 STRIPING PLAN FOR N. ROSEMARY AVE. IS THE PLAN TO NOT
 RESTORE THE NEIGHBORHOOD MUSICAL THEME PAVEMENT
 STRIPING?
  
 21. [NOT SATISFIED] SHEET C-9 INCLUDES A VEHICULAR AREA
 PAVER DETAIL. PLEASE IDENTIFY WHERE THESE AREAS ARE ON
 THE PGD PLAN.
 NEW COMMENTS (2/17/2023 SUBMITTAL)
  
 22. JUSTIFY THE OUTFALL DIAMETER LARGER THAN 15 INCHES.
  
 23. THE EXISTING DRAINAGE STRUCTURE THAT THE OUTFALL
 PIPE CONNECTS INTO MAY NOT BE BIG ENOUGH TO ACCOMMODATE
 THE NEW PIPE CONNECTION.
  
 24. IF THE PAVEMENT ADJACENT TO AN EXISTING CURB RAMP
 IS MODIFIED IN ANY MANNER (INCLUDING MILL AND
 RESURFACING), THE CURB RAMP IS TO BE RECONSTRUCTED TO
 MEET CURRENT ADA CRITERIA IF THE RAMP DOES NOT MEET ADA
 CRITERIA.
  
 25. ALL ONSITE DRAINAGE INFRASTRUCTURE SHALL NOT
 ENCROACH INTO THE RIGHT OF WAY.
  
 CONDITIONS FOR SITE PLAN APPROVAL
 A. LIST VERTICAL DATUM REFERENCE AND CONVERSION
 EQUATION TO NGVD1929 ON ALL SHEETS WITH ELEVATION
 INFORMATION.
  
 B. SHOW AND LABEL ALL EXISTING UTILITY LINES (SIZE,
 MATERIAL, TYPE ? STORM, SAN., WM, ETC.) ON THE
 ENGINEERING PLANS.
  
 C. SHOW THE PROPOSED SIDEWALKS BEHIND A LANDSCAPE STRIP
 TRANSITIONING TO THE EXISTING SIDEWALKS ADJACENT TO THE
 CURB AT ALL PROPERTY LINES.
  
 D. DRIVEWAY APRONS WITHIN THE RIGHT OF WAY TO BE
 CONCRETE PER CITY DETAILS GC-5 AND GC-6.
  
 E. CALLOUT MODIFICATIONS TO EXISTING DRAINAGE
 STRUCTURES THAT WILL BE IMPACTED BY THE DEVELOPMENT.
 VALLEY GUTTER MAY BE NEEDED ACROSS DRIVEWAY CONNECTIONS
 TO THE STREET.
  
 F. PROVIDE CROSS SECTIONS PER COMMENT #14 ABOVE.
 SIDEWALK AREA ACROSS DRIVEWAY APRONS TO BE MEET WIDTH
 AND ADA CRITERIA.
  
 G. COORDINATE LANDSCAPING AND STORMWATER SYSTEM DESIGN.
 THE PROPOSED WIDTH OF THE AXFILTRATION TRENCHES WILL
 TAKE UP MOST IF NOT ALL OF THE PLANTING AREA WHERE SOME
 OF THE EXFILTRATION TRENCHES ARE LOCATED.
  
 H. EXFILTRATION TRENCHES LOCATED WITHIN THE BUILDING OR
 UNDERNEATH BUILDING SUFFICIENT VERTICAL CLEARANCE FOR
 MAINTENANCE VEHICLES TO CLEAN THE DRAINAGE SYSTEM AND
 FOR CONSTRUCTION EQUIPMENT TO REPLACE THE EXFILTRATION
 TRENCHES WHEN THEY DO NOT FUNCTION AS DESIGNED.
  
 I. PAVEMENT MARKINGS AND SIGNAGE TO BE IN ACCORDANCE
 WITH MUTCD. LABEL ALL PROPOSED MARKINGS AND SIGNS.
  
 J. SHOULD THE 4TH STREET EXTENSION EASEMENT BECOME
 PUBLIC RIGHT OF WAY, MAINTENANCE RESPONSIBILITY OF THE
 DRAINAGE SYSTEM WITHIN THE R/W SHALL BECOME THE
 RESPONSIBILITY OF THE DEVELOPER.
  
  
 TRACY WARD, PE
 SENIOR STORMWATER ENGINEER
 ENGINEERING SERVICES DEPARTMENT
 561-494-1120 (O)
 [email protected]
  

Review Stop STORM STORMWATER
Rev No 1 Status F Date 09-08-2022 Cont ID  
Sent By tward Date 09-08-2022 Time 12:48 Rev Time 0.00
Received By tward Date 09-08-2022 Time 12:49 Sent To  
Notes
2022-09-08 12:49:38THIS IS A CONCEPTUAL LEVEL REVIEW. CONSTRUCTION LEVEL
 DETAILS, DESIGN CALCULATIONS AND THE POLLUTION
 PREVENTION PLAN WILL BE REVIEWED AS PART OF THE
 ENGINEERING DEVELOPMENT APPROVAL AND BUILDING PERMIT
 APPLICATION PROCESSES.
 THE FOLLOWING COMMENTS MUST BE ADDRESSED PRIOR TO SITE
 PLAN APPROVAL:
  
 1. THE CITY?S OFFICIAL VERTICAL DATUM IS NGVD1929. THE
 CITY HAS ALLOWED THE USE OF NAVD1988 AS LONG AS THE
 CONVERSION EQUATION TO NGVD1929 AT THE PROJECT LOCATION
 IS PROVIDED. PROVIDE VERTICAL DATUM CONVERSION TO
 NGVD1929 ON THE SURVEYS. SEVERAL OF THE SURVEYS LIST
 NAVD1988 AS THE VERTICAL DATUM BUT THERE MAY NOT BE
 ELEVATION DATA ON THE SURVEYS.
  
 2. PROVIDE SCALE BAR ON THE ARCHITECTURAL PLANS. THE
 LISTED SCALES (1/8? = 1 FEET) ON THE FLOOR PLANS
 (SHEETS A2.1, A2.2, ETC.) ARE DOUBLE THE SCALE OF WHAT
 IS PRESENTED ON THE DRAWINGS.
  
 3. SHOW UTILITIES ON THE LANDSCAPE PLANS.
  
 4. SHOW AND LABEL ALL EXISTING UTILITY LINES (SIZE,
 MATERIAL, TYPE ? STORM, SAN., WM, ETC.) ON THE
 ENGINEERING PLANS.
  
 5. PORTIONS OF NORTH AND EAST EXISTING CHAIN LINK
 FENCING IS ON PROPERTY NOT OWNED BY THE APPLICANT.
  
 6. PORTION OF PROPOSED NORTH DRIVEWAY APRON TO W.
 RAILROAD AVE WILL BE ON PROPERTY NOT OWNED BY
 APPLICANT.
  
 7. PORTION OF ROADWAY, SIDEWALK AND DRAINAGE SYSTEM IN
 THE MIDDLE OF THE DEVELOPMENT IS LOCATED ON PROPERTY
 NOT OWNED BY THE APPLICANT.
  
 8. PROPOSED SIDEWALK ON ADJACENT PROPERTY TO THE NORTH
 ALONG W. RAILROAD AVE DOES NOT ALIGN WITH THE EXISTING
 SIDEWALK.
  
 9. SIDEWALK EASEMENT WILL BE NEEDED FOR THE PROPOSED
 SIDEWALK ALONG THE SOUTH AND EAST PROPERTY LINES AND
 POSSIBLY THE SIDEWALK ENCROACHMENT ON THE WEST PROPERTY
 LINE.
  
 10. SHOW SIDEWALK CONNECTION AND CURB RAMP TO THE
 CROSSWALK ON 3RD STREET.
  
 11. SIDEWALK EAST OF EAST DRIVEWAY TO 3RD STREET WILL
 BE ON PROPERTY NOT OWNED BY THE APPLICANT NOR DOES THE
 PROPOSED SIDEWALK ALIGN WITH THE EXISTING SIDEWALK.
  
 12. DRIVEWAY APRONS WITHIN THE RIGHT OF WAY SHOULD BE
 CONCRETE.
  
 13. DRIVEWAY LOCATIONS WILL AFFECT EXISTING DRAINAGE
 STRUCTURES WITHIN THE RIGHT OF WAY.
  
 14. PROVIDE CROSS SECTIONS FOR THE FOLLOWING. SHOW, IF
 APPLICABLE, RIGHT OF WAY LINE, STREET NAME, GRADE
 BREAKS, SURFACE FEATURES, DIMENSIONS FROM RIGHT OF WAY
 TO BACK OF SIDEWALK, FACE OF BUILDING, HIGH POINTS OF
 DRIVEWAYS, BACK OF CURB, ETC.
 A. ALL DRIVEWAY CONNECTIONS TO THE RIGHT OF WAY.
 SECTION TO EXTEND FROM CENTERLINE OF RIGHT OF WAY TO 5
 FEET BEYOND HIGH POINT OF DRIVEWAY.
 B. NORTH-SOUTH SECTION ON THE 4TH STREET DRIVE
 EXTENSION FROM FACE OF BUILDING TO FACE OF BUILDING.
 C. FROM CENTERLINE OF RIGHT OF WAY TO EACH BUILDING
 FACE.
 D. FROM NORTH FACE OF NORTH BUILDING TO THE EXISTING
 PARKING LOT ON THE PROPERTY TO THE NORTH. THE SECTION
 TO BE LOCATED WITHIN THE LONGER NORTH PROPERTY LINE.
  
 15. DRAW THE OUTLINE OF THE EXFILTRATION TRENCH TO THE
 DESIGN WIDTH (EXFILTRATION TRENCH DETAIL SHOWS 10 FEET
 WIDE TRENCH) ON THE PLANS. FOR THE EXFILTRATION TRENCH
 ALONG W. RAILROAD AVE., THE TRENCH WILL BE THE WIDTH OF
 THE SIDEWALK AND EXTEND FROM THE RIGHT OF WAY LINE TO
 THE BUILDING FACE. FOR THE EXFILTRATION TRENCH ALONG
 THE EXTENSION OF 4TH STREET, THE CENTER OF THE PIPE IS
 LESS THAN 5 FEET FROM THE SOUTH BUILDING. BUILDING
 FOUNDATIONS WILL NEED TO BE DESIGNED SO THAT THE SLAB
 WILL NOT BE UNDERMINED WHEN THE EXFILTRATION TRENCH
 WILL BE REPLACED WHEN IT IS NO LONGER FUNCTIONING AS
 DESIGNED. ANY SLAB ADJACENT TO THE TRENCH WILL IMPEDE
 THE FLOW OUT THAT SIDE OF THE TRENCH AND SHOULD BE
 ACCOUNTED FOR IN THE EXFILTRATION TRENCH EQUATION.
  
 16. CONSIDER THERE WILL BE PROPER VERTICAL CLEARANCE
 FOR MAINTAINING THE DRAINAGE SYSTEM AND REPLACING THE
 EXFILTRATION TRENCH SYSTEM WHEN IT IS NO LONGER
 FUNCTIONING AS DESIGNED WITHIN THE ENCLOSED PARKING
 AREAS OF THE BUILDING.
  
 17. CONSIDER LOW IMPACT DEVELOPMENT DRAINAGE SYSTEMS IN
 LIEU OR IN COMBINATION WITH THE EXFILTRATION TRENCH
 SYSTEM.
  
 18. NUMBER THE DRAINAGE STRUCTURES FOR EASE OF
 REFERENCE. NO DESIGN INFORMATION (RIM, INVERT
 ELEVATIONS) IS PROVIDED.
  
 19. THE OUTFALL CONNECTION TO CITY DRAINAGE SYSTEM
 APPEARS TO BE MISLABELED. IT IS SHOWN POINTING TO THE
 FIRST NORTH-SOUTH PIPE SOUTH OF THE 4TH STREET
 EXTENSION AND EAST OF THE BUILDING.
  
 20. SIGNING AND PAVEMENT MARKINGS:
 A. STOP BAR AND SIGN NEEDED FOR SERVICE DRIVE DRIVEWAY
 AND GARAGE ACCESS DRIVEWAY TO W. RAILROAD AVE.
 B. STOP BAR AND SIGN NEEDED FOR THE TWO DRIVEWAYS TO
 3RD STREET.
 C. DO NOT ENTER AND ONE-WAY SIGNS AT EAST END OF 4TH
 STREET EXTENSION DRIVE.
 D. ONE WAY SIGN AT WEST END OF 4TH STREET EXTENSION
 DRIVE.
 E. SHARED BIKE LANE SIGNS FOR N. ROSEMARY.
 F. PROVIDE STRIPING PLAN FOR N. ROSEMARY AVE. IS THE
 PLAN TO NOT RESTORE THE NEIGHBORHOOD MUSICAL THEME
 PAVEMENT STRIPING?
  
 21. SHEET C-8 INCLUDES A VEHICULAR AREA PAVER DETAIL.
 PLEASE IDENTIFY WHERE THESE AREAS ARE ON THE PGD PLAN.
  
 THE FOLLOWING COMMENTS MUST BE ADDRESSED PRIOR TO
 ISSUANCE OF CONSTRUCTION AUTHORIZATION INCLUDING
 BUILDING PERMITS AND ENGINEERING DEVELOPMENT APPROVAL.
  
 1. DRAINAGE SYSTEM TO BE DESIGNED TO MEET SFWMD ERP
 CRITERIA. STORMWATER CALCULATIONS WILL BE REVIEWED WITH
 THE ENGINEERING PERMIT SUBMITTAL.
  
 2. PROVIDE COPY OF SFWMD ERP PERMIT BEFORE START OF
 CONSTRUCTION.
  
 3. PROVIDE EROSION AND SEDIMENT CONTROL PLAN WITH THE
 ENGINEERING PERMIT SUBMITTAL.
  
 TRACY WARD, PE
 SENIOR STORMWATER ENGINEER
 ENGINEERING SERVICES DEPARTMENT
 561-494-1120 (O)
 561-351-0510 (M)
 [email protected]
  

Review Stop SURVEY SURVEYING
Rev No 2 Status P Date 03-06-2023 Cont ID  
Sent By vnoel Date 03-06-2023 Time 12:17 Rev Time 0.00
Received By vnoel Date   Time   Sent To  
Notes
2023-03-06 12:22:31PASSED WITH CONDITIONS:
  
 1. RESPNOSE TO COMMENTS ON 10.14.2022 STATED THAT
 REPLAT HAD BEEN SUBMITTED. NO REPLAT OR MINOR
 SUBDIVISION APPLICATION WAS RECEIVED.
 2. REPLAT WILL BE REQUIRED PRIOR TO C.O.
 3. EXISTING EASEMENT HAS BEEN SENT TO OUR LAW DEPT. FOR
 REVIEW AS CITY WAS NOT A PARTY TO IT.

Review Stop SURVEY SURVEYING
Rev No 1 Status F Date 09-07-2022 Cont ID  
Sent By vnoel Date 09-07-2022 Time 10:24 Rev Time 0.00
Received By vnoel Date   Time   Sent To  
Notes
2022-09-07 11:04:041. REPLAT WILL BE REQUIRED. PUBLIC ACCESS EASEMENT WILL
 BE REQUIRED OVER 4TH STREET.
 2. NEED CONSENT FROM ADJACENT OWNER AS TO 4TH STREET
 IMPROVEMENTS.
 3. DOORWAY SHOULD NOT OPEN INTO SIDEWALK ALONG W.
 RAILROAD AVE.
 4. NORTH SERVICE ROAD TURNOUT CANNOT ENCROACH INTO
 ADJOINING PROPERTY. MOVE ROADWAY OFF OF PROPERTY LINE.
 5. NEED BLOW-UP OF PROPOSED METER/BACKFLOW/LANDSCAPE
 AREAS.
 6. R/W MAINTENANCE AGREEMENT WILL BE REQUIRED.

Review Stop TRAFFIC TRAFFIC ENGINEERING
Rev No 5 Status P Date 03-06-2023 Cont ID  
Sent By   Date 03-06-2023 Time   Rev Time 0.00
Received By   Date 03-06-2023 Time   Sent To  
Notes
2023-03-06 22:39:02APPROVED WITH THE FOLLOWING CONDITIONS:
 1) DUE TO THE PROXIMITY TO THE INTERSECTION AND THE
 ROAD CONFIGURATION, THE DRIVEWAY ON 3RD ST SHOULD BE
 RIGHT-IN ONLY, NO LEFT-TURNING INBOUND MOVEMENTS SHOULD
 BE ALLOWED. PLEASE INSTALL AN ISLAND AT THE DRIVEWAY
 DESIGNED TO ENFORCE SUCH VEHICULAR MOVEMENT
 PROHIBITION.
  
 PREVIOUS COMMENTS
 1) SATISFIED. PROVIDE A DETAILED TRAFFIC STUDY. A
 METHODOLOGY MEETING SHALL BE SCHEDULED PRIOR TO
 DRAFTING THE ANALYSIS.
 2) SATISFIED. PLEASE INSERT PERTINENT SUMMARY TABLES
 AND FIGURES WITHIN THE MAIN BODY OF THE REPORT, SUCH AS
 DRIVEWAY VOLUMES, SITE LOCATION, TRIP GENERATION, LOS
 SUMMARY, ETC. APPENDIX SHOULD BE USED AND REFERENCED
 FOR LARGE TABLES AND FIGURES SUCH AS SYNCHRO OUTPUTS,
 SIGNAL PLANS, BACKGROUND VOLUMES, ETC. SEVERAL SAMPLE
 TRAFFIC STUDIES HAVE BEEN PROVIDED. PLEASE REFER TO
 THOSE STUDIES FOR PROPER FORMATTING AND REFERENCING
 3) SATISFIED. PLEASE NAME AND/OR NUMBER EACH TABLE,
 FIGURE AND REFERENCED DOCUMENT
 4) SATISFIED. PLEASE INSERT PAGE NUMBERING THROUGHOUT
 THE REPORT, INCLUDING THE APPENDIX, AND UPDATE THE
 TABLE OF CONTENT ACCORDINGLY
 5) SATISFIED. PLEASE REVISE FIGURE 2. PERCENTAGES
 SHOULD BE PLACED MID-BLOCK AND PROPERLY ADD-UP. IT
 SEEMS ONLY 50% OF THE TRAFFIC IS COMING IN/OUT OF THE
 SITE
 6) SATISFIED. PLEASE REVISE FIGURE 3. TURNING MOVEMENTS
 WITH NO VOLUMES SHOULD BE REMOVED, DAILY TRAFFIC
 VOLUMES PROVIDED
 7) SATISFIED. PLEASE PROVIDE A CONCLUSION PARAGRAPH IN
 THE TRAFFIC STUDY, SUMMARIZING ALL FINDINGS AND
 HIGHLIGHTING ALL DEFICIENCIES AND SIGNIFICANT IMPACTS,
 TOGETHER WITH PROPOSED/POTENTIAL MITIGATION MEASURES,
 IF ANY
 8) SATISFIED. PROVIDE A CLEAN TRANSPORTATION SPECIFIC
 SITE PLAN FOR THE GROUND FLOOR. SHOWCASING
 TRANSPORTATION RELATED FEATURES (E.G. ROADWAY WIDTHS,
 DRIVING AISLES, PARKING STALLS, SIDEWALK, CURB, GUTTER,
 DRIVEWAY, GATES, CROSSWALKS, VISIBILITY TRIANGLE,
 CORNER & DRIVEWAY SEPARATION DISTANCES, SLOPES, ETC.)
 PROPERLY LABELED AND DIMENSIONED. THE SITE PLAN SHOULD
 BE NAMED T-1.0. PLEASE PROVIDE A SPECIFIC SITE PLAN AS
 REQUESTED. SHEET A1 AND C5 DO NOT PROPERLY DEPICT NOR
 PROVIDE ALL THE REQUESTED ITEMS. MOREOVER, ITEMS
 IMPACTING PEDESTRIAN MOVEMENT SUCH AS PLANTERS AND
 TRAFFIC/UTILITY POLES ALONG THE SIDEWALK AREAS MUST BE
 SHOWN; BASED ON THOSE ITEMS AND ALONG CHOKE POINTS, THE
 EFFECTIVE SIDEWALK WIDTH SHOULD BE PROPERLY SHOWN AND
 DIMENSIONED
 9) SATISFIED. IN THE T-1.0 SITE PLAN, PLEASE SHOWCASE
 BASIC CURB DETAILS (E.G. DRIVEWAY, CURB CUTS, PAVEMENT
 MARKINGS, PARKING STALLS, GARAGE ENTRANCES, ETC.) ON
 THE OPPOSITE SIDE OF THE ROADS SURROUNDING THE PROPOSED
 DEVELOPMENT. PLEASE PROVIDE A SPECIFIC TRANSPORTATION
 SITE PLAN AS REQUESTED
 10) SATISFIED. THE PAVEMENT, MARKING & SIGNAGE PLAN IS
 INCOMPLETE. PLEASE PROVIDE ALL EXISTING AND PROPOSED
 FEATURES WITHIN THE PROPOSED DEVELOPMENT AND ALONG ALL
 THE ROADS FRONTING THE SITE. THIS SITE PLAN CAN BE
 CONSIDERED PART OF THE TRANSPORTATION REVIEW AND COULD
 BE EITHER INCLUDED IN THE T-1 SITE PLAN OR NAMED T-1.2.
 RESPONSE LETTER INDICATES SHEET C-7, CORRECT SHEET
 WOULD BE C-8. NONETHELESS, INSTALL A ONE-WAY SIGN ON
 THE EAST LEG OF THE ROSEMARY & 4TH ST INTERSECTION,
 STOP SIGN AND STOP BARS SHOULD BE INSTALLED AT EACH
 GARAGE AND DRIVEWAY EXITS, SERVICE DRIVEWAYS SHOULD BE
 INDICATED AD SIGNED AS SUCH, DEAD-END DRIVEWAYS SHOULD
 BE SIGNED AS SUCH.
 11) SATISFIED. PROVIDE AUTOTURN ANALYSIS FOR GARBAGE
 TRUCK AND/OR SERVICE VEHICLES DRIVING IN AND OUT OF THE
 PROPOSED DEVELOPMENT WITH VEHICLE DYNAMIC ENVELOPES AND
 WHEEL PATHS CLEARLY DISTINCT AND DEFINED IN DIFFERENT
 COLORS. SITE PLAN(S) CONTAINING THE ANALYSIS SHOULD BE
 CONSIDERED PART OF THE TRANSPORTATION REVIEW AND NAMED
 ACCORDINGLY (E.G. T1.2, T-3). ENGINEERING SERVICES CAN
 PROVIDE SAMPLE AUTOTURN ANALYSES. LATEST AUTOTURN DOES
 NOT PROVIDE THE REQUESTED FEATURES. RESPONSE AND
 MATERIAL PROVIDED IS COMPLETELY UNSATISFACTORY.
 ENGINEERING HAS OFFERED TO PROVIDE SAMPLE PROPER
 AUTOTURN ANALYSES, WHICH WERE NOT REQUESTED BY THE
 APPLICANT. MOREOVER, THERE ARE SIGNIFICANT MAJOR
 ENCROACHMENTS SHOWN; THUS, THE PROPOSED LOADING ZONES
 ARE NOT FEASIBLE, NOR THE PROPOSED SITE PLAN COULD BE
 CONDITIONALLY APPROVED UNTIL THIS ITEM IS FULLY AND
 PROPERLY ADDRESSED. THE ANALYSIS MUST SHOW ALL POSSIBLE
 OR ALLOWED ACCESS TRAVEL PATHS (I.E TO OR FROM THE
 EAST/WEST AND THE NORTH/SOUTH FOR THE RAILROAD AVE AND
 3RD ST LOADING ZONE DRIVEWAYS, RESPECTIVELY)
 12) SATISFIED. IDENTIFY AND DESIGNATE AN EASILY
 ACCESSIBLE MICRO-MOBILITY STATION AREA (MINIMUM 8 X 20
 FEET) AND PROVIDE BASIC ELECTRIFICATION READINESS WITH
 THE FOLLOWING SPECS: A CONDUIT (2-INCH SCHEDULE 40 PVC)
 TO THE POWER SOURCE WITH AN ELECTRICAL PULL BOX (240V -
 10,000W CIRCUIT). PLEASE INSERT THIS ITEM IN THE T-1 OR
 T-2 SITE PLAN
 13) SATISFIED. DEPENDING ON THE OUTCOME OF THE TRAFFIC
 ANALYSIS, PROVIDE TRANSPORTATION DEMAND MANAGEMENT
 (TDM) MEASURES. PLEASE PROVIDE A NUMBERED AND SPECIFIC
 LIST OF POTENTIAL TDMS IN THE TRAFFIC STUDY. PLEASE
 PROVIDE PAGE NUMBER WHERE THIS ITEM IS ADDRESSED. NO
 NUMBERED LIST, NOR DETAILED TDM WERE PROVIDED IN THE
 LATEST RESUBMISSION, JUST GENERAL OBSERVATIONS AND
 DESCRIPTIONS OF EXISTING TRANSIT OPERATIONS. THE
 MULTI-MODAL PARAGRAPH SEEMED A RUSHED EFFORT, AS IT
 SHOULD BE MORE DETAILED AND EXHAUSTIVE: HAVE AN IMAGE
 DEPICTING LOCATION AND DISTANCES TO EXISTING TRANSIT
 ROUTES/FACILITIES, PROVIDE EXACT NUMBER OF BOTH SHORT
 AND LONG-TERM BICYCLE PARKING (NOT PARING) STALLS,
 PROPOSE ACTUAL MITIGATION MEASURES SUCH AS TRANSIT
 DISCOUNTS OR SUBSIDIES FOR RESIDENTS AND EMPLOYEES,
 INCENTIVES FOR CAR-POOLING AND SO ON
 14) SATISFIED. PROVIDE A PARKING TABLE SHOWCASING THE
 NUMBER OF REQUIRED AND PROVIDED PARKING SPACES,
 INCLUSIVE OF ADA AND BICYCLE ONES
 15) SATISFIED. IN THE PAVEMENT, MARKING & SIGN PLAN,
 PROVIDE A TABLE SHOWCASING THE NUMBER OF EXISTING AND
 PROPOSED ON-STREET PARKING STALLS. PROVIDE THE NUMBER
 OF METERED STALLS THAT ARE BEING REMOVED OR RELOCATED,
 IF ANY
 16) SATISFIED. ARE THERE ANY GATES PROPOSED? IF SO,
 CLEARLY SHOWCASE THE REQUIRED 20 FEET SETBACK DISTANCE
 FROM THE BACK OF THE SIDEWALK
 17) SATISFIED. IS VALET SERVICE PROPOSED? IF SO,
 PROVIDE AN OPERATIONAL ANALYSIS. DETAILS OF THE
 ANALYSIS SHOULD BE DISCUSSED DURING THE METHODOLOGY
 MEETING
 18) SATISFIED. PROVIDE AND PROPERLY MARK A TURN-AROUND
 SPACE/STALL AT EACH DEAD-END OF THE GARAGE. FROM SHEET
 A2.1 IT IS NOT CLEAR WHERE AND IF THE LOADING ZONE IS
 CONNECTED TO THE FIRST FLOOR OF THE NORTHERN GARAGE.
 PLEASE CLARIFY, AS A TURN-AROUND SPACE MAY BE NEEDED AT
 THAT LOCATION OTHERWISE. SEVERAL DEAD-ENDS ARE MISSING
 OR THE TURN-AROUND SPACES ARE NOT PROPERLY MARKED
 19) SATISFIED. IN THE GARAGE PLANS, ALL THE DRIVE
 AISLES, RAMPS AND AT LEAST A SET OF PARKING SPACES IN
 EACH FLOOR SHOULD BE DIMENSIONED
 20) SATISFIED. PER CITY CODE SEC94-111(C)(1): ???IN
 THOSE CASES WHERE THE SIDE OF ANY STALL IS ADJACENT TO
 A WALL, FENCE, BUILDING, OR OTHER PHYSICAL OBSTRUCTION,
 THE STALL WIDTHS SHALL BE INCREASED BY A MINIMUM OF ONE
 FOOT. WHERE THERE IS AN OBSTRUCTION ON BOTH SIDES OF
 THE STALL, THE STALL WIDTHS SHALL BE INCREASED BY A
 MINIMUM OF TWO FEET.???
 21) SATISFIED. HOW MANY GARAGE FLOORS ARE THERE? SHEET
 A2.3 SHOWS TWO UP-RAMPS FROM THE THIRD FLOOR, IS THERE
 A FOURTH? PLEASE CLARIFY OR CORRECT THE TEXT/ARROWS.
 AWAITING NEXT ROUND OF PLANS TO CLEAR THIS COMMENT
 22) SATISFIED. INSTALL CROSSWALKS ON THE NORTHERN AND
 EASTERN LEG OF THE ROSEMARY AND 4TH ST INTERSECTION.
 THERE IS A PORTION OF THE ONE-WAY DRIVE WITHIN PUBLIC
 ROW; THUS, A CROSSWALK AND CORRESPONDING RAMPS ARE
 WARRANTED. DRAWINGS CAN BE REVISED AT ENGINEERING
 PERMITTING. HOWEVER, AGREEMENT AND CONFIRMATION OF THE
 CROSSWALKS IMPLEMENTATION SHOULD BE PROVIDED AT THIS
 STAGE
 23) SATISFIED. SHEET C-8 POINTS AT GATE(S) AT THE
 EASTERN LEG OF THE ROSEMARY AND 4TH INTERSECTION. ARE
 THOSE PEDESTRIAN AND/OR VEHICULAR GATES? IF SO, THEY
 MAY NEED TO BE MOVED FURTHER EAST TO ACCOMMODATE THE
 PEDESTRIAN CROSSING
 24) SATISFIED. PROVIDE BIKE RACKS WITHIN OR NEARBY THE
 PUBLIC OPEN SPACE AREA
 25) SATISFIED. PROVIDE A CONSTRUCTION MANAGEMENT PLAN.
 PLEASE REFER TO CITY CODE 86-246 FOR DETAILS
 26) TO BE SATISFIED. DUE TO THE PROXIMITY TO THE
 INTERSECTION AND THE ROAD CONFIGURATION, THE DRIVEWAY
 ON 3RD ST SHOULD BE RIGHT-IN ONLY, NO LEFT-TURNING
 INBOUND MOVEMENTS SHOULD BE ALLOWED. PLEASE INSTALL AN
 ISLAND AT THE DRIVEWAY DESIGNED TO ENFORCE SUCH
 VEHICULAR MOVEMENT PROHIBITION. NOTE: THE ONLY MOVEMENT
 PROHIBITED IS THE LEFT-IN, AS VEHICLES DRIVING
 EASTBOUND ON 3RD ST WANTING TO TURN LEFT INTO THE
 GARAGE AND AWAITING FOR A GAP MAY CAUSE MAJOR
 CONGESTION AND UNSAFE TRAFFIC CONDITIONS. AS A
 COMPROMISE, THE LEFT-OUT TURNING MOVEMENT WOULD BE
 ALLOWED, AS ANY QUEUE BACKUP WOULD BE CONTAINED WITHIN
 THE GARAGE
  
 VALERIO ORICCHIO
 CITY TRANSPORTATION ENGINEER
 561-494-1092
 [email protected]
  

Review Stop TRAFFIC TRAFFIC ENGINEERING
Rev No 4 Status F Date 02-22-2023 Cont ID  
Sent By   Date 02-22-2023 Time   Rev Time 0.00
Received By   Date 02-22-2023 Time   Sent To  
Notes
2023-02-22 21:48:28TRAFFIC COMMENTS
 1) SATISFIED. PROVIDE A DETAILED TRAFFIC STUDY. A
 METHODOLOGY MEETING SHALL BE SCHEDULED PRIOR TO
 DRAFTING THE ANALYSIS.
 2) SATISFIED. PLEASE INSERT PERTINENT SUMMARY TABLES
 AND FIGURES WITHIN THE MAIN BODY OF THE REPORT, SUCH AS
 DRIVEWAY VOLUMES, SITE LOCATION, TRIP GENERATION, LOS
 SUMMARY, ETC. APPENDIX SHOULD BE USED AND REFERENCED
 FOR LARGE TABLES AND FIGURES SUCH AS SYNCHRO OUTPUTS,
 SIGNAL PLANS, BACKGROUND VOLUMES, ETC. SEVERAL SAMPLE
 TRAFFIC STUDIES HAVE BEEN PROVIDED. PLEASE REFER TO
 THOSE STUDIES FOR PROPER FORMATTING AND REFERENCING
 3) SATISFIED. PLEASE NAME AND/OR NUMBER EACH TABLE,
 FIGURE AND REFERENCED DOCUMENT
 4) SATISFIED. PLEASE INSERT PAGE NUMBERING THROUGHOUT
 THE REPORT, INCLUDING THE APPENDIX, AND UPDATE THE
 TABLE OF CONTENT ACCORDINGLY
 5) SATISFIED. PLEASE REVISE FIGURE 2. PERCENTAGES
 SHOULD BE PLACED MID-BLOCK AND PROPERLY ADD-UP. IT
 SEEMS ONLY 50% OF THE TRAFFIC IS COMING IN/OUT OF THE
 SITE
 6) SATISFIED. PLEASE REVISE FIGURE 3. TURNING MOVEMENTS
 WITH NO VOLUMES SHOULD BE REMOVED, DAILY TRAFFIC
 VOLUMES PROVIDED
 7) PARTIALLY SATISFIED. PLEASE PROVIDE A CONCLUSION
 PARAGRAPH IN THE TRAFFIC STUDY, SUMMARIZING ALL
 FINDINGS AND HIGHLIGHTING ALL DEFICIENCIES AND
 SIGNIFICANT IMPACTS, TOGETHER WITH PROPOSED/POTENTIAL
 MITIGATION MEASURES, IF ANY.
  
 SITE COMMENTS
 8) SATISFIED. PROVIDE A CLEAN TRANSPORTATION SPECIFIC
 SITE PLAN FOR THE GROUND FLOOR. SHOWCASING
 TRANSPORTATION RELATED FEATURES (E.G. ROADWAY WIDTHS,
 DRIVING AISLES, PARKING STALLS, SIDEWALK, CURB, GUTTER,
 DRIVEWAY, GATES, CROSSWALKS, VISIBILITY TRIANGLE,
 CORNER & DRIVEWAY SEPARATION DISTANCES, SLOPES, ETC.)
 PROPERLY LABELED AND DIMENSIONED. THE SITE PLAN SHOULD
 BE NAMED T-1.0. PLEASE PROVIDE A SPECIFIC SITE PLAN AS
 REQUESTED. SHEET A1 AND C5 DO NOT PROPERLY DEPICT NOR
 PROVIDE ALL THE REQUESTED ITEMS. MOREOVER, ITEMS
 IMPACTING PEDESTRIAN MOVEMENT SUCH AS PLANTERS AND
 TRAFFIC/UTILITY POLES ALONG THE SIDEWALK AREAS MUST BE
 SHOWN; BASED ON THOSE ITEMS AND ALONG CHOKE POINTS, THE
 EFFECTIVE SIDEWALK WIDTH SHOULD BE PROPERLY SHOWN AND
 DIMENSIONED
 9) SATISFIED. IN THE T-1.0 SITE PLAN, PLEASE SHOWCASE
 BASIC CURB DETAILS (E.G. DRIVEWAY, CURB CUTS, PAVEMENT
 MARKINGS, PARKING STALLS, GARAGE ENTRANCES, ETC.) ON
 THE OPPOSITE SIDE OF THE ROADS SURROUNDING THE PROPOSED
 DEVELOPMENT. PLEASE PROVIDE A SPECIFIC TRANSPORTATION
 SITE PLAN AS REQUESTED
 10) SATISFIED. THE PAVEMENT, MARKING & SIGNAGE PLAN IS
 INCOMPLETE. PLEASE PROVIDE ALL EXISTING AND PROPOSED
 FEATURES WITHIN THE PROPOSED DEVELOPMENT AND ALONG ALL
 THE ROADS FRONTING THE SITE. THIS SITE PLAN CAN BE
 CONSIDERED PART OF THE TRANSPORTATION REVIEW AND COULD
 BE EITHER INCLUDED IN THE T-1 SITE PLAN OR NAMED T-1.2.
 RESPONSE LETTER INDICATES SHEET C-7, CORRECT SHEET
 WOULD BE C-8. NONETHELESS, INSTALL A ONE-WAY SIGN ON
 THE EAST LEG OF THE ROSEMARY & 4TH ST INTERSECTION,
 STOP SIGN AND STOP BARS SHOULD BE INSTALLED AT EACH
 GARAGE AND DRIVEWAY EXITS, SERVICE DRIVEWAYS SHOULD BE
 INDICATED AD SIGNED AS SUCH, DEAD-END DRIVEWAYS SHOULD
 BE SIGNED AS SUCH.
 11) NOT SATISFIED. PROVIDE AUTOTURN ANALYSIS FOR
 GARBAGE TRUCK AND/OR SERVICE VEHICLES DRIVING IN AND
 OUT OF THE PROPOSED DEVELOPMENT WITH VEHICLE DYNAMIC
 ENVELOPES AND WHEEL PATHS CLEARLY DISTINCT AND DEFINED
 IN DIFFERENT COLORS. SITE PLAN(S) CONTAINING THE
 ANALYSIS SHOULD BE CONSIDERED PART OF THE
 TRANSPORTATION REVIEW AND NAMED ACCORDINGLY (E.G. T1.2,
 T-3). ENGINEERING SERVICES CAN PROVIDE SAMPLE AUTOTURN
 ANALYSES. LATEST AUTOTURN DOES NOT PROVIDE THE
 REQUESTED FEATURES. RESPONSE AND MATERIAL PROVIDED IS
 COMPLETELY UNSATISFACTORY. ENGINEERING HAS OFFERED TO
 PROVIDE SAMPLE PROPER AUTOTURN ANALYSES, WHICH WERE NOT
 REQUESTED BY THE APPLICANT. MOREOVER, THERE ARE
 SIGNIFICANT MAJOR ENCROACHMENTS SHOWN; THUS, THE
 PROPOSED LOADING ZONES ARE NOT FEASIBLE, NOR THE
 PROPOSED SITE PLAN COULD BE CONDITIONALLY APPROVED
 UNTIL THIS ITEM IS FULLY AND PROPERLY ADDRESSED
 12) SATISFIED. IDENTIFY AND DESIGNATE AN EASILY
 ACCESSIBLE MICRO-MOBILITY STATION AREA (MINIMUM 8 X 20
 FEET) AND PROVIDE BASIC ELECTRIFICATION READINESS WITH
 THE FOLLOWING SPECS: A CONDUIT (2-INCH SCHEDULE 40 PVC)
 TO THE POWER SOURCE WITH AN ELECTRICAL PULL BOX (240V -
 10,000W CIRCUIT). PLEASE INSERT THIS ITEM IN THE T-1 OR
 T-2 SITE PLAN
 13) PARTIALLY SATISFIED. DEPENDING ON THE OUTCOME OF
 THE TRAFFIC ANALYSIS, PROVIDE TRANSPORTATION DEMAND
 MANAGEMENT (TDM) MEASURES. PLEASE PROVIDE A NUMBERED
 AND SPECIFIC LIST OF POTENTIAL TDMS IN THE TRAFFIC
 STUDY. PLEASE PROVIDE PAGE NUMBER WHERE THIS ITEM IS
 ADDRESSED. NO NUMBERED LIST, NOR DETAILED TDM WERE
 PROVIDED IN THE LATEST RESUBMISSION, JUST GENERAL
 OBSERVATIONS AND DESCRIPTIONS OF EXISTING TRANSIT
 OPERATIONS. THE MULTI-MODAL PARAGRAPH SEEMED A RUSHED
 EFFORT, AS IT SHOULD BE MORE DETAILED AND EXHAUSTIVE:
 HAVE AN IMAGE DEPICTING LOCATION AND DISTANCES TO
 EXISTING TRANSIT ROUTES/FACILITIES, PROVIDE EXACT
 NUMBER OF BOTH SHORT AND LONG-TERM BICYCLE PARKING (NOT
 PARING) STALLS, PROPOSE ACTUAL MITIGATION MEASURES SUCH
 AS TRANSIT DISCOUNTS OR SUBSIDIES FOR RESIDENTS AND
 EMPLOYEES, INCENTIVES FOR CAR-POOLING AND SO ON
 14) SATISFIED. PROVIDE A PARKING TABLE SHOWCASING THE
 NUMBER OF REQUIRED AND PROVIDED PARKING SPACES,
 INCLUSIVE OF ADA AND BICYCLE ONES
 15) SATISFIED. IN THE PAVEMENT, MARKING & SIGN PLAN,
 PROVIDE A TABLE SHOWCASING THE NUMBER OF EXISTING AND
 PROPOSED ON-STREET PARKING STALLS. PROVIDE THE NUMBER
 OF METERED STALLS THAT ARE BEING REMOVED OR RELOCATED,
 IF ANY
 16) SATISFIED. ARE THERE ANY GATES PROPOSED? IF SO,
 CLEARLY SHOWCASE THE REQUIRED 20 FEET SETBACK DISTANCE
 FROM THE BACK OF THE SIDEWALK
 17) SATISFIED. IS VALET SERVICE PROPOSED? IF SO,
 PROVIDE AN OPERATIONAL ANALYSIS. DETAILS OF THE
 ANALYSIS SHOULD BE DISCUSSED DURING THE METHODOLOGY
 MEETING
 18) SATISFIED. PROVIDE AND PROPERLY MARK A TURN-AROUND
 SPACE/STALL AT EACH DEAD-END OF THE GARAGE. FROM SHEET
 A2.1 IT IS NOT CLEAR WHERE AND IF THE LOADING ZONE IS
 CONNECTED TO THE FIRST FLOOR OF THE NORTHERN GARAGE.
 PLEASE CLARIFY, AS A TURN-AROUND SPACE MAY BE NEEDED AT
 THAT LOCATION OTHERWISE. SEVERAL DEAD-ENDS ARE MISSING
 OR THE TURN-AROUND SPACES ARE NOT PROPERLY MARKED
 19) SATISFIED. IN THE GARAGE PLANS, ALL THE DRIVE
 AISLES, RAMPS AND AT LEAST A SET OF PARKING SPACES IN
 EACH FLOOR SHOULD BE DIMENSIONED
 20) SATISFIED. PER CITY CODE SEC94-111(C)(1): ???IN
 THOSE CASES WHERE THE SIDE OF ANY STALL IS ADJACENT TO
 A WALL, FENCE, BUILDING, OR OTHER PHYSICAL OBSTRUCTION,
 THE STALL WIDTHS SHALL BE INCREASED BY A MINIMUM OF ONE
 FOOT. WHERE THERE IS AN OBSTRUCTION ON BOTH SIDES OF
 THE STALL, THE STALL WIDTHS SHALL BE INCREASED BY A
 MINIMUM OF TWO FEET.???
 21) SATISFIED. HOW MANY GARAGE FLOORS ARE THERE? SHEET
 A2.3 SHOWS TWO UP-RAMPS FROM THE THIRD FLOOR, IS THERE
 A FOURTH? PLEASE CLARIFY OR CORRECT THE TEXT/ARROWS.
 AWAITING NEXT ROUND OF PLANS TO CLEAR THIS COMMENT
 22) SATISFIED. INSTALL CROSSWALKS ON THE NORTHERN AND
 EASTERN LEG OF THE ROSEMARY AND 4TH ST INTERSECTION.
 THERE IS A PORTION OF THE ONE-WAY DRIVE WITHIN PUBLIC
 ROW; THUS, A CROSSWALK AND CORRESPONDING RAMPS ARE
 WARRANTED. DRAWINGS CAN BE REVISED AT ENGINEERING
 PERMITTING. HOWEVER, AGREEMENT AND CONFIRMATION OF THE
 CROSSWALKS IMPLEMENTATION SHOULD BE PROVIDED AT THIS
 STAGE
 23) SATISFIED. SHEET C-8 POINTS AT GATE(S) AT THE
 EASTERN LEG OF THE ROSEMARY AND 4TH INTERSECTION. ARE
 THOSE PEDESTRIAN AND/OR VEHICULAR GATES? IF SO, THEY
 MAY NEED TO BE MOVED FURTHER EAST TO ACCOMMODATE THE
 PEDESTRIAN CROSSING
 24) SATISFIED. PROVIDE BIKE RACKS WITHIN OR NEARBY THE
 PUBLIC OPEN SPACE AREA
 25) SATISFIED. PROVIDE A CONSTRUCTION MANAGEMENT PLAN.
 PLEASE REFER TO CITY CODE 86-246 FOR DETAILS
 26) NOT SATISFIED. DUE TO THE PROXIMITY TO THE
 INTERSECTION AND THE ROAD CONFIGURATION, THE DRIVEWAY
 ON 3RD ST SHOULD BE RIGHT-IN ONLY, NO LEFT-TURNING
 INBOUND MOVEMENTS SHOULD BE ALLOWED. PLEASE INSTALL AN
 ISLAND AT THE DRIVEWAY DESIGNED TO ENFORCE SUCH
 VEHICULAR MOVEMENT PROHIBITION. NOTE: THE ONLY MOVEMENT
 PROHIBITED IS THE LEFT-IN, AS VEHICLES DRIVING
 EASTBOUND ON 3RD ST WANTING TO TURN LEFT INTO THE
 GARAGE AND AWAITING FOR A GAP MAY CAUSE MAJOR
 CONGESTION AND UNSAFE TRAFFIC CONDITIONS. AS A
 COMPROMISE, THE LEFT-OUT TURNING MOVEMENT WOULD BE
 ALLOWED, AS ANY QUEUE BACKUP WOULD BE CONTAINED WITHIN
 THE GARAGE
  
 VALERIO ORICCHIO
 CITY TRANSPORTATION ENGINEER
 561-494-1092
 [email protected]
  

Review Stop TRAFFIC TRAFFIC ENGINEERING
Rev No 3 Status F Date 02-16-2023 Cont ID  
Sent By voricchi Date 02-16-2023 Time   Rev Time 0.00
Received By   Date 02-16-2023 Time   Sent To  
Notes
2023-02-16 17:01:49TRAFFIC COMMENTS
 1) SATISFIED. PROVIDE A DETAILED TRAFFIC STUDY. A
 METHODOLOGY MEETING SHALL BE SCHEDULED PRIOR TO
 DRAFTING THE ANALYSIS.
 2) SATISFIED. PLEASE INSERT PERTINENT SUMMARY TABLES
 AND FIGURES WITHIN THE MAIN BODY OF THE REPORT, SUCH AS
 DRIVEWAY VOLUMES, SITE LOCATION, TRIP GENERATION, LOS
 SUMMARY, ETC. APPENDIX SHOULD BE USED AND REFERENCED
 FOR LARGE TABLES AND FIGURES SUCH AS SYNCHRO OUTPUTS,
 SIGNAL PLANS, BACKGROUND VOLUMES, ETC. SEVERAL SAMPLE
 TRAFFIC STUDIES HAVE BEEN PROVIDED. PLEASE REFER TO
 THOSE STUDIES FOR PROPER FORMATTING AND REFERENCING
 3) SATISFIED. PLEASE NAME AND/OR NUMBER EACH TABLE,
 FIGURE AND REFERENCED DOCUMENT
 4) SATISFIED. PLEASE INSERT PAGE NUMBERING THROUGHOUT
 THE REPORT, INCLUDING THE APPENDIX, AND UPDATE THE
 TABLE OF CONTENT ACCORDINGLY
 5) SATISFIED. PLEASE REVISE FIGURE 2. PERCENTAGES
 SHOULD BE PLACED MID-BLOCK AND PROPERLY ADD-UP. IT
 SEEMS ONLY 50% OF THE TRAFFIC IS COMING IN/OUT OF THE
 SITE
 6) SATISFIED. PLEASE REVISE FIGURE 3. TURNING MOVEMENTS
 WITH NO VOLUMES SHOULD BE REMOVED, DAILY TRAFFIC
 VOLUMES PROVIDED
 7) PLEASE PROVIDE A CONCLUSION PARAGRAPH IN THE TRAFFIC
 STUDY, SUMMARIZING ALL FINDINGS AND HIGHLIGHTING ALL
 DEFICIENCIES AND SIGNIFICANT IMPACTS, TOGETHER WITH
 PROPOSED/POTENTIAL MITIGATION MEASURES, IF ANY
 SITE COMMENTS
 8) SATISFIED. PROVIDE A CLEAN TRANSPORTATION SPECIFIC
 SITE PLAN FOR THE GROUND FLOOR. SHOWCASING
 TRANSPORTATION RELATED FEATURES (E.G. ROADWAY WIDTHS,
 DRIVING AISLES, PARKING STALLS, SIDEWALK, CURB, GUTTER,
 DRIVEWAY, GATES, CROSSWALKS, VISIBILITY TRIANGLE,
 CORNER & DRIVEWAY SEPARATION DISTANCES, SLOPES, ETC.)
 PROPERLY LABELED AND DIMENSIONED. THE SITE PLAN SHOULD
 BE NAMED T-1.0. PLEASE PROVIDE A SPECIFIC SITE PLAN AS
 REQUESTED. SHEET A1 AND C5 DO NOT PROPERLY DEPICT NOR
 PROVIDE ALL THE REQUESTED ITEMS. MOREOVER, ITEMS
 IMPACTING PEDESTRIAN MOVEMENT SUCH AS PLANTERS AND
 TRAFFIC/UTILITY POLES ALONG THE SIDEWALK AREAS MUST BE
 SHOWN; BASED ON THOSE ITEMS AND ALONG CHOKE POINTS, THE
 EFFECTIVE SIDEWALK WIDTH SHOULD BE PROPERLY SHOWN AND
 DIMENSIONED
 9) SATISFIED. IN THE T-1.0 SITE PLAN, PLEASE SHOWCASE
 BASIC CURB DETAILS (E.G. DRIVEWAY, CURB CUTS, PAVEMENT
 MARKINGS, PARKING STALLS, GARAGE ENTRANCES, ETC.) ON
 THE OPPOSITE SIDE OF THE ROADS SURROUNDING THE PROPOSED
 DEVELOPMENT. PLEASE PROVIDE A SPECIFIC TRANSPORTATION
 SITE PLAN AS REQUESTED
 10) SATISFIED. THE PAVEMENT, MARKING & SIGNAGE PLAN IS
 INCOMPLETE. PLEASE PROVIDE ALL EXISTING AND PROPOSED
 FEATURES WITHIN THE PROPOSED DEVELOPMENT AND ALONG ALL
 THE ROADS FRONTING THE SITE. THIS SITE PLAN CAN BE
 CONSIDERED PART OF THE TRANSPORTATION REVIEW AND COULD
 BE EITHER INCLUDED IN THE T-1 SITE PLAN OR NAMED T-1.2.
 RESPONSE LETTER INDICATES SHEET C-7, CORRECT SHEET
 WOULD BE C-8. NONETHELESS, INSTALL A ONE-WAY SIGN ON
 THE EAST LEG OF THE ROSEMARY & 4TH ST INTERSECTION,
 STOP SIGN AND STOP BARS SHOULD BE INSTALLED AT EACH
 GARAGE AND DRIVEWAY EXITS, SERVICE DRIVEWAYS SHOULD BE
 INDICATED AD SIGNED AS SUCH, DEAD-END DRIVEWAYS SHOULD
 BE SIGNED AS SUCH.
 11) NOT SATISFIED. PROVIDE AUTOTURN ANALYSIS FOR
 GARBAGE TRUCK AND/OR SERVICE VEHICLES DRIVING IN AND
 OUT OF THE PROPOSED DEVELOPMENT WITH VEHICLE DYNAMIC
 ENVELOPES AND WHEEL PATHS CLEARLY DISTINCT AND DEFINED
 IN DIFFERENT COLORS. SITE PLAN(S) CONTAINING THE
 ANALYSIS SHOULD BE CONSIDERED PART OF THE
 TRANSPORTATION REVIEW AND NAMED ACCORDINGLY (E.G. T1.2,
 T-3). ENGINEERING SERVICES CAN PROVIDE SAMPLE AUTOTURN
 ANALYSES. LATEST AUTOTURN DOES NOT PROVIDE THE
 REQUESTED FEATURES.
 12) SATISFIED. IDENTIFY AND DESIGNATE AN EASILY
 ACCESSIBLE MICRO-MOBILITY STATION AREA (MINIMUM 8 X 20
 FEET) AND PROVIDE BASIC ELECTRIFICATION READINESS WITH
 THE FOLLOWING SPECS: A CONDUIT (2-INCH SCHEDULE 40 PVC)
 TO THE POWER SOURCE WITH AN ELECTRICAL PULL BOX (240V -
 10,000W CIRCUIT). PLEASE INSERT THIS ITEM IN THE T-1 OR
 T-2 SITE PLAN
 13) PARTIALLY SATISFIED. DEPENDING ON THE OUTCOME OF
 THE TRAFFIC ANALYSIS, PROVIDE TRANSPORTATION DEMAND
 MANAGEMENT (TDM) MEASURES. PLEASE PROVIDE A NUMBERED
 AND SPECIFIC LIST OF POTENTIAL TDMS IN THE TRAFFIC
 STUDY. PLEASE PROVIDE PAGE NUMBER WHERE THIS ITEM IS
 ADDRESSED
 14) SATISFIED. PROVIDE A PARKING TABLE SHOWCASING THE
 NUMBER OF REQUIRED AND PROVIDED PARKING SPACES,
 INCLUSIVE OF ADA AND BICYCLE ONES
 15) SATISFIED. IN THE PAVEMENT, MARKING & SIGN PLAN,
 PROVIDE A TABLE SHOWCASING THE NUMBER OF EXISTING AND
 PROPOSED ON-STREET PARKING STALLS. PROVIDE THE NUMBER
 OF METERED STALLS THAT ARE BEING REMOVED OR RELOCATED,
 IF ANY
 16) SATISFIED. ARE THERE ANY GATES PROPOSED? IF SO,
 CLEARLY SHOWCASE THE REQUIRED 20 FEET SETBACK DISTANCE
 FROM THE BACK OF THE SIDEWALK
 17) SATISFIED. IS VALET SERVICE PROPOSED? IF SO,
 PROVIDE AN OPERATIONAL ANALYSIS. DETAILS OF THE
 ANALYSIS SHOULD BE DISCUSSED DURING THE METHODOLOGY
 MEETING
 18) SATISFIED. PROVIDE AND PROPERLY MARK A TURN-AROUND
 SPACE/STALL AT EACH DEAD-END OF THE GARAGE. FROM SHEET
 A2.1 IT IS NOT CLEAR WHERE AND IF THE LOADING ZONE IS
 CONNECTED TO THE FIRST FLOOR OF THE NORTHERN GARAGE.
 PLEASE CLARIFY, AS A TURN-AROUND SPACE MAY BE NEEDED AT
 THAT LOCATION OTHERWISE. SEVERAL DEAD-ENDS ARE MISSING
 OR THE TURN-AROUND SPACES ARE NOT PROPERLY MARKED
 19) SATISFIED. IN THE GARAGE PLANS, ALL THE DRIVE
 AISLES, RAMPS AND AT LEAST A SET OF PARKING SPACES IN
 EACH FLOOR SHOULD BE DIMENSIONED
 20) SATISFIED. PER CITY CODE SEC94-111(C)(1): ???IN
 THOSE CASES WHERE THE SIDE OF ANY STALL IS ADJACENT TO
 A WALL, FENCE, BUILDING, OR OTHER PHYSICAL OBSTRUCTION,
 THE STALL WIDTHS SHALL BE INCREASED BY A MINIMUM OF ONE
 FOOT. WHERE THERE IS AN OBSTRUCTION ON BOTH SIDES OF
 THE STALL, THE STALL WIDTHS SHALL BE INCREASED BY A
 MINIMUM OF TWO FEET.???
 21) PARTIALLY SATISFIED. HOW MANY GARAGE FLOORS ARE
 THERE? SHEET A2.3 SHOWS TWO UP-RAMPS FROM THE THIRD
 FLOOR, IS THERE A FOURTH? PLEASE CLARIFY OR CORRECT THE
 TEXT/ARROWS. AWAITING NEXT ROUND OF PLANS TO CLEAR THIS
 COMMENT
 22) NOT SATISFIED. INSTALL CROSSWALKS ON THE NORTHERN
 AND EASTERN LEG OF THE ROSEMARY AND 4TH ST
 INTERSECTION. THERE IS A PORTION OF THE ONE-WAY DRIVE
 WITHIN PUBLIC ROW; THUS, A CROSSWALK AND CORRESPONDING
 RAMPS ARE WARRANTED. DRAWINGS CAN BE REVISED AT
 ENGINEERING PERMITTING. HOWEVER, AGREEMENT AND
 CONFIRMATION OF THE CROSSWALKS IMPLEMENTATION SHOULD BE
 PROVIDED AT THIS STAGE
 23) SATISFIED. SHEET C-8 POINTS AT GATE(S) AT THE
 EASTERN LEG OF THE ROSEMARY AND 4TH INTERSECTION. ARE
 THOSE PEDESTRIAN AND/OR VEHICULAR GATES? IF SO, THEY
 MAY NEED TO BE MOVED FURTHER EAST TO ACCOMMODATE THE
 PEDESTRIAN CROSSING
 24) SATISFIED. PROVIDE BIKE RACKS WITHIN OR NEARBY THE
 PUBLIC OPEN SPACE AREA
 25) SATISFIED. PROVIDE A CONSTRUCTION MANAGEMENT PLAN.
 PLEASE REFER TO CITY CODE 86-246 FOR DETAILS
 26) DUE TO THE PROXIMITY TO THE INTERSECTION AND THE
 ROAD CONFIGURATION, THE DRIVEWAY ON 3RD ST SHOULD BE
 RIGHT-IN ONLY, NO LEFT-TURNING INBOUND MOVEMENTS SHOULD
 BE ALLOWED. PLEASE INSTALL AN ISLAND AT THE DRIVEWAY
 DESIGNED TO ENFORCE SUCH VEHICULAR MOVEMENT PROHIBITION
  
  
  
 VALERIO ORICCHIO
 CITY TRANSPORTATION ENGINEER
 561-494-1092
 [email protected]
  

Review Stop TRAFFIC TRAFFIC ENGINEERING
Rev No 2 Status F Date 11-11-2022 Cont ID  
Sent By   Date 11-11-2022 Time   Rev Time 0.00
Received By   Date 11-11-2022 Time   Sent To  
Notes
2022-11-11 02:42:02TRAFFIC COMMENTS
 1) SATISFIED. PROVIDE A DETAILED TRAFFIC STUDY. A
 METHODOLOGY MEETING SHALL BE SCHEDULED PRIOR TO
 DRAFTING THE ANALYSIS.
 2) PLEASE INSERT PERTINENT SUMMARY TABLES AND FIGURES
 WITHIN THE MAIN BODY OF THE REPORT, SUCH AS DRIVEWAY
 VOLUMES, SITE LOCATION, TRIP GENERATION, LOS SUMMARY,
 ETC. APPENDIX SHOULD BE USED AND REFERENCED FOR LARGE
 TABLES AND FIGURES SUCH AS SYNCHRO OUTPUTS, SIGNAL
 PLANS, BACKGROUND VOLUMES, ETC. SEVERAL SAMPLE TRAFFIC
 STUDIES HAVE BEEN PROVIDED. PLEASE REFER TO THOSE
 STUDIES FOR PROPER FORMATTING AND REFERENCING
 3) PLEASE NAME AND/OR NUMBER EACH TABLE, FIGURE AND
 REFERENCED DOCUMENT
 4) PLEASE INSERT PAGE NUMBERING THROUGHOUT THE REPORT,
 INCLUDING THE APPENDIX, AND UPDATE THE TABLE OF CONTENT
 ACCORDINGLY
 5) PLEASE REVISE FIGURE 2. PERCENTAGES SHOULD BE PLACED
 MID-BLOCK AND PROPERLY ADD-UP. IT SEEMS ONLY 50% OF THE
 TRAFFIC IS COMING IN/OUT OF THE SITE
 6) PLEASE REVISE FIGURE 3. TURNING MOVEMENTS WITH NO
 VOLUMES SHOULD BE REMOVED, DAILY TRAFFIC VOLUMES
 PROVIDED
  
 SITE COMMENTS
 7) NOT SATISFIED. PROVIDE A CLEAN TRANSPORTATION
 SPECIFIC SITE PLAN FOR THE GROUND FLOOR. SHOWCASING
 TRANSPORTATION RELATED FEATURES (E.G. ROADWAY WIDTHS,
 DRIVING AISLES, PARKING STALLS, SIDEWALK, CURB, GUTTER,
 DRIVEWAY, GATES, CROSSWALKS, VISIBILITY TRIANGLE,
 CORNER & DRIVEWAY SEPARATION DISTANCES, SLOPES, ETC.)
 PROPERLY LABELED AND DIMENSIONED. THE SITE PLAN SHOULD
 BE NAMED T-1.0. PLEASE PROVIDE A SPECIFIC SITE PLAN AS
 REQUESTED. SHEET A1 AND C5 DO NOT PROPERLY DEPICT NOR
 PROVIDE ALL THE REQUESTED ITEMS. MOREOVER, ITEMS
 IMPACTING PEDESTRIAN MOVEMENT SUCH AS PLANTERS AND
 TRAFFIC/UTILITY POLES ALONG THE SIDEWALK AREAS MUST BE
 SHOWN; BASED ON THOSE ITEMS AND ALONG CHOKE POINTS, THE
 EFFECTIVE SIDEWALK WIDTH SHOULD BE PROPERLY SHOWN AND
 DIMENSIONED
 8) NOT SATISFIED. IN THE T-1.0 SITE PLAN, PLEASE
 SHOWCASE BASIC CURB DETAILS (E.G. DRIVEWAY, CURB CUTS,
 PAVEMENT MARKINGS, PARKING STALLS, GARAGE ENTRANCES,
 ETC.) ON THE OPPOSITE SIDE OF THE ROADS SURROUNDING THE
 PROPOSED DEVELOPMENT. PLEASE PROVIDE A SPECIFIC
 TRANSPORTATION SITE PLAN AS REQUESTED
 9) PARTIALLY SATISFIED. THE PAVEMENT, MARKING & SIGNAGE
 PLAN IS INCOMPLETE. PLEASE PROVIDE ALL EXISTING AND
 PROPOSED FEATURES WITHIN THE PROPOSED DEVELOPMENT AND
 ALONG ALL THE ROADS FRONTING THE SITE. THIS SITE PLAN
 CAN BE CONSIDERED PART OF THE TRANSPORTATION REVIEW AND
 COULD BE EITHER INCLUDED IN THE T-1 SITE PLAN OR NAMED
 T-1.2. RESPONSE LETTER INDICATES SHEET C-7, CORRECT
 SHEET WOULD BE C-8. NONETHELESS, INSTALL A ONE-WAY SIGN
 ON THE EAST LEG OF THE ROSEMARY & 4TH ST INTERSECTION,
 STOP SIGN AND STOP BARS SHOULD BE INSTALLED AT EACH
 GARAGE AND DRIVEWAY EXITS, SERVICE DRIVEWAYS SHOULD BE
 INDICATED AD SIGNED AS SUCH, DEAD-END DRIVEWAYS SHOULD
 BE SIGNED AS SUCH.
 10) NOT SATISFIED. PROVIDE AUTOTURN ANALYSIS FOR
 GARBAGE TRUCK AND/OR SERVICE VEHICLES DRIVING IN AND
 OUT OF THE PROPOSED DEVELOPMENT WITH VEHICLE DYNAMIC
 ENVELOPES AND WHEEL PATHS CLEARLY DISTINCT AND DEFINED
 IN DIFFERENT COLORS. SITE PLAN(S) CONTAINING THE
 ANALYSIS SHOULD BE CONSIDERED PART OF THE
 TRANSPORTATION REVIEW AND NAMED ACCORDINGLY (E.G. T1.2,
 T-3). ENGINEERING SERVICES CAN PROVIDE SAMPLE AUTOTURN
 ANALYSES
 11) SATISFIED. IDENTIFY AND DESIGNATE AN EASILY
 ACCESSIBLE MICRO-MOBILITY STATION AREA (MINIMUM 8 X 20
 FEET) AND PROVIDE BASIC ELECTRIFICATION READINESS WITH
 THE FOLLOWING SPECS: A CONDUIT (2-INCH SCHEDULE 40 PVC)
 TO THE POWER SOURCE WITH AN ELECTRICAL PULL BOX (240V -
 10,000W CIRCUIT). PLEASE INSERT THIS ITEM IN THE T-1 OR
 T-2 SITE PLAN
 12) PARTIALLY SATISFIED. DEPENDING ON THE OUTCOME OF
 THE TRAFFIC ANALYSIS, PROVIDE TRANSPORTATION DEMAND
 MANAGEMENT (TDM) MEASURES. PLEASE PROVIDE A NUMBERED
 AND SPECIFIC LIST OF POTENTIAL TDMS IN THE TRAFFIC
 STUDY
 13) SATISFIED. PROVIDE A PARKING TABLE SHOWCASING THE
 NUMBER OF REQUIRED AND PROVIDED PARKING SPACES,
 INCLUSIVE OF ADA AND BICYCLE ONES
 14) SATISFIED. IN THE PAVEMENT, MARKING & SIGN PLAN,
 PROVIDE A TABLE SHOWCASING THE NUMBER OF EXISTING AND
 PROPOSED ON-STREET PARKING STALLS. PROVIDE THE NUMBER
 OF METERED STALLS THAT ARE BEING REMOVED OR RELOCATED,
 IF ANY
 15) SATISFIED. ARE THERE ANY GATES PROPOSED? IF SO,
 CLEARLY SHOWCASE THE REQUIRED 20 FEET SETBACK DISTANCE
 FROM THE BACK OF THE SIDEWALK
 16) SATISFIED. IS VALET SERVICE PROPOSED? IF SO,
 PROVIDE AN OPERATIONAL ANALYSIS. DETAILS OF THE
 ANALYSIS SHOULD BE DISCUSSED DURING THE METHODOLOGY
 MEETING
 17) PARTIALLY SATISFIED. PROVIDE AND PROPERLY MARK A
 TURN-AROUND SPACE/STALL AT EACH DEAD-END OF THE GARAGE.
 FROM SHEET A2.1 IT IS NOT CLEAR WHERE AND IF THE
 LOADING ZONE IS CONNECTED TO THE FIRST FLOOR OF THE
 NORTHERN GARAGE. PLEASE CLARIFY, AS A TURN-AROUND SPACE
 MAY BE NEEDED AT THAT LOCATION OTHERWISE. SEVERAL
 DEAD-ENDS ARE MISSING OR THE TURN-AROUND SPACES ARE NOT
 PROPERLY MARKED
 18) IN THE GARAGE PLANS, ALL THE DRIVE AISLES, RAMPS
 AND AT LEAST A SET OF PARKING SPACES IN EACH FLOOR
 SHOULD BE DIMENSIONED
 19) PER CITY CODE SEC94-111(C)(1): ???IN THOSE CASES
 WHERE THE SIDE OF ANY STALL IS ADJACENT TO A WALL,
 FENCE, BUILDING, OR OTHER PHYSICAL OBSTRUCTION, THE
 STALL WIDTHS SHALL BE INCREASED BY A MINIMUM OF ONE
 FOOT. WHERE THERE IS AN OBSTRUCTION ON BOTH SIDES OF
 THE STALL, THE STALL WIDTHS SHALL BE INCREASED BY A
 MINIMUM OF TWO FEET.???
 20) HOW MANY GARAGE FLOORS ARE THERE? SHEET A2.3 SHOWS
 TWO UP-RAMPS FROM THE THIRD FLOOR, IS THERE A FOURTH?
 PLEASE CLARIFY OR CORRECT THE TEXT/ARROWS
 21) INSTALL CROSSWALKS ON THE NORTHERN AND EASTERN LEG
 OF THE ROSEMARY AND 4TH ST INTERSECTION
 22) SHEET C-8 POINTS AT GATE(S) AT THE EASTERN LEG OF
 THE ROSEMARY AND 4TH INTERSECTION. ARE THOSE PEDESTRIAN
 AND/OR VEHICULAR GATES? IF SO, THEY MAY NEED TO BE
 MOVED FURTHER EAST TO ACCOMMODATE THE PEDESTRIAN
 CROSSING
 23) PROVIDE BIKE RACKS WITHIN OR NEARBY THE PUBLIC OPEN
 SPACE AREA
 24) PROVIDE A CONSTRUCTION MANAGEMENT PLAN. PLEASE
 REFER TO CITY CODE 86-246 FOR DETAILS.
  
 VALERIO ORICCHIO
 CITY TRANSPORTATION ENGINEER
 561-494-1092
 [email protected]
  

Review Stop TRAFFIC TRAFFIC ENGINEERING
Rev No 1 Status F Date 09-07-2022 Cont ID  
Sent By   Date 09-07-2022 Time   Rev Time 0.00
Received By   Date 09-07-2022 Time   Sent To  
Notes
2022-09-07 18:49:10 
 1) PROVIDE A DETAILED TRAFFIC STUDY. A METHODOLOGY
 MEETING SHALL BE SCHEDULED PRIOR TO DRAFTING THE
 ANALYSIS
 2) PROVIDE A CLEAN TRANSPORTATION SPECIFIC SITE PLAN
 FOR THE GROUND FLOOR. SHOWCASING TRANSPORTATION RELATED
 FEATURES (E.G. ROADWAY WIDTHS, DRIVING AISLES, PARKING
 STALLS, SIDEWALK, CURB, GUTTER, DRIVEWAY, GATES,
 CROSSWALKS, VISIBILITY TRIANGLE, CORNER & DRIVEWAY
 SEPARATION DISTANCES, SLOPES, ETC.) PROPERLY LABELED
 AND DIMENSIONED. THE SITE PLAN SHOULD BE NAMED T-1.0
 3) IN THE T-1.0 SITE PLAN, PLEASE SHOWCASE BASIC CURB
 DETAILS (E.G. DRIVEWAY, CURB CUTS, PAVEMENT MARKINGS,
 PARKING STALLS, ETC.) ON THE OPPOSITE SIDE OF THE ROADS
 SURROUNDING THE PROPOSED DEVELOPMENT
 4) THE PAVEMENT, MARKING & SIGNAGE PLAN IS INCOMPLETE.
 PLEASE PROVIDE ALL EXISTING AND PROPOSED FEATURES
 WITHIN THE PROPOSED DEVELOPMENT AND ALONG ALL THE ROADS
 FRONTING THE SITE. THIS SITE PLAN CAN BE CONSIDERED
 PART OF THE TRANSPORTATION REVIEW AND COULD BE EITHER
 INCLUDED IN THE T-1 SITE PLAN OR NAMED T-1.2
 5) PROVIDE AUTOTURN ANALYSIS FOR GARBAGE TRUCK AND/OR
 SERVICE VEHICLES DRIVING IN AND OUT OF THE PROPOSED
 DEVELOPMENT WITH VEHICLE DYNAMIC ENVELOPES AND WHEEL
 PATHS CLEARLY DISTINCT AND DEFINED IN DIFFERENT COLORS.
 SITE PLAN(S) CONTAINING THE ANALYSIS SHOULD BE
 CONSIDERED PART OF THE TRANSPORTATION REVIEW AND NAMED
 ACCORDINGLY (E.G. T1.2, T-3)
 6) IDENTIFY AND DESIGNATE AN EASILY ACCESSIBLE
 MICRO-MOBILITY STATION AREA (MINIMUM 8 X 20 FEET) AND
 PROVIDE BASIC ELECTRIFICATION READINESS WITH THE
 FOLLOWING SPECS: A CONDUIT (2 INCH SCHEDULE 40 PVC) TO
 THE POWER SOURCE WITH AN ELECTRICAL PULL BOX (240V ?
 10,000W CIRCUIT). PLEASE INSERT THIS ITEM IN THE T-1 OR
 T-2 SITE PLAN
 7) DEPENDING ON THE OUTCOME OF THE TRAFFIC ANALYSIS,
 PROVIDE TRANSPORTATION DEMAND MANAGEMENT (TDM) MEASURES
 8) PROVIDE A PARKING TABLE SHOWCASING THE NUMBER OF
 REQUIRED AND PROVIDED PARKING SPACES, INCLUSIVE OF ADA
 AND BICYCLE ONES
 9) IN THE PAVEMENT, MARKING & SIGN PLAN, PROVIDE A
 TABLE SHOWCASING THE NUMBER OF EXISTING AND PROPOSED
 ON-STREET PARKING STALLS. PROVIDE THE NUMBER OF METERED
 STALLS THAT ARE BEING REMOVED OR RELOCATED, IF ANY
 10) ARE THERE ANY GATES PROPOSED? IF SO, CLEARLY
 SHOWCASE THE REQUIRED 20 FEET SETBACK DISTANCE FROM THE
 BACK OF THE SIDEWALK
 11) IS VALET SERVICE PROPOSED? IF SO, PROVIDE AN
 OPERATIONAL ANALYSIS. DETAILS OF THE ANALYSIS SHOULD BE
 DISCUSSED DURING THE METHODOLOGY MEETING
 12) PROVIDE AND PROPERLY MARK A TURN-AROUND SPACE/STALL
 AT EACH DEAD-END OF THE GARAGE
  
 VALERIO ORICCHIO
 CITY TRANSPORTATION ENGINEER
 561-494-1092
 [email protected]
  

Review Stop Z ZONING
Rev No 5 Status P Date 03-23-2023 Cont ID  
Sent By cibaven Date 03-23-2023 Time 12:53 Rev Time 0.00
Received By cibaven Date 03-23-2023 Time 12:53 Sent To  
Notes
2023-03-23 12:53:21ZONING AND PLANNING
  
 PROJECT: SOLESTE FSPR 22-19
 DATE: 03.23.23
  
 CONTACT: CLAUDIA IBAVEN, CITY URBAN DESIGNER, AT
 561-822-1402 OR VIA [email protected].
 I HAVE REVIEWED THE ABOVE REFERENCED PETITION AND
 PROVIDE THE FOLLOWING COMMENTS:
  
  
 ZONING DATA AND DIAGRAMS
  
 1. ON SHEET A1.5, ACTIVE USE: PLEASE REVISE BOTH
 DIMENSIONS AND TABLE CALCULATIONS BASED ON THE
 FOLLOWING:
 - FACING N ROSEMARY AVE, THE DIMENSIONS OF THE
 'BUILDABLE LOT FRONTAGE' OF THE NORTH BUILDING SHOULD
 BE FROM THE SETBACK TO THE SOUTH END OF THE OPEN SPACE.
 ACTIVE USE DIMENSION (179FT) IS NOT SHOWN ON THE TABLE.
  
 DIMENSIONS AND TABLE UPDATED
  
 Z 03.15.23 ??? SATISFIED
  
 - FACING N ROSEMARY AVE, THE DIMENSIONS OF THE
 'BUILDABLE LOT FRONTAGE' OF THE SOUTH BUILDING SHOULD
 BE FROM THE SETBACK TO NORTH END OF OPEN SPACE.
 COURTYARD SHOULD BE INCLUDED AS ACTIVE USE.
  
 DIMENSIONS AND TABLE UPDATED
  
 Z 03.15.23 ??? SATISFIED
  
 - FACING W RAILROAD AVE, THE DIMENSION OF 'BUILDABLE
 LOT FRONTAGE' OF 196FT AND 'ACTIVE USE' OF 77FT DO NOT
 MATCH THE TABLE.
 DIMENSIONS AND TABLE UPDATED
  
 Z 03.15.23 ??? SATISFIED
  
 - FACING 3RD STREET, PLEASE NOTE ENCLOSED STAIRS DO NOT
 COUNT AS ACTIVE USE, PLEASE EXCLUDE FROM DIMENSIONS AND
 CALCULATIONS.
 DIMENSIONS AND TABLE UPDATED
  
 Z 03.15.23 ??? SATISFIED
  
  
 2. ON SHEET A1.5, PLANAR BREAKS: THE COURTYARD ALSO IS
 A PLANAR BREAK, PLEASE INCLUDE IN YOUR CALCULATIONS.
  
 DIMENSIONS AND TABLE UPDATED
  
 Z 03.15.23 ??? SATISFIED
  
 3. ON SHEET A1.5, HORIZONTAL PROJECTIONS: THERE ARE
 DOTTED LINES THAT SEEM TO BE HORIZONTAL PROJECTIONS BUT
 ARE NOT COUNTED AS SUCH, PLEASE REVIEW. AND, PLEASE
 MAKE SURE HORIZONTAL PROJECTIONS MATCH OTHER PLANS AND
 RENDERINGS.
  
 DIMENSIONS AND GRAPHICS UPDATED
  
 Z 03.15.23 ??? SATISFIED
  
 4. ON SHEET A1.4 - OPEN SPACE: PLEASE NOTE, THERE IS NO
 BREAKDOWN SHOWING WHERE THE 2,270SQ.FT. OF SEMI-OPEN
 SPACE IS COMING FROM. IN ADDITION, THERE ARE SOME
 WALK-UP GARDENS THAT LOOK DIFFERENT IN CONFIGURATION
 FROM THE SAMPLES. AND SAMPLES ARE SHOWING OVERHEAD
 COVERAGES DIFFERENT FROM FLOOR PLANS AND RENDERINGS.
  
 SQUARE FOOTAGES OF THE THREE SEMI-PUBLIC OPEN SPACE
 ZONES ADDED. TOTAL SEMI-PUBLIC AREA UPDATED. FOUR
 ADDITIONAL SAMPLE WALK-UP GARDEN DETAILS ADDED (SHEET
 A1.4A). OVERHEAD COVERING GRAPHICS UPDATED.
  
 Z 03.15.23 ??? NOT SATISFIED.
  
 ON SHEETS A1.4 AND A1.4A, WALK-UP GARDENS:
 ??? PLEASE REVISE ON TABLES, THE ACTIVE USE ABUTMENT
 REQUIREMENTS
  
 TABLES REVISED TO REFLECT REQUIREMENTS FROM ZONING
 TABLE.
  
 Z 03.23.23 ??? SATISFIED. MINOR EDIT, COURTYARD FACING
 ROSEMARY RD PROVIDES 2 SIDES ONLY, NOT 3. THE OTHER 2
 ARE ROW AND CIRCULATION HALL THAT IS NOT ACTIVE USE.
  
 Z 03.23.23 ??? SATISFIED.
  
 ??? WALK-UP GARDENS SQ.FT. TOTALS DO NOT MATCH WHEN
 ADDING UP, PLEASE REVIEW AND REVISE CALCULATIONS.
  
 ALL WALK UP GARDENS LABELED TO SHOW INDIVIDUAL AREAS.
 TOTAL SEMI-PUBLIC AREA UPDATED.
  
 Z 03.23.23 ??? SATISFIED. MINOR EDIT, ON SHEET A1.4,
 LABELS CALLING OUT SEMI???PUBLIC OPEN SPACE HAVE SOME
 SQUARE FOOTAGE ON THEM THAT DOES NOT ADD UP, PLEASE
 REMOVE THEM.
  
 ??? WALK-UP GARDEN SECTION SHOWS A BALCONY PROJECTION
 LESS THAN THE MINIMUM REQUIRED OF 3 FEET, PLEASE
 REVISE, AND REVISE ANY CALCULATIONS ON YOUR PLANS.
 PLEASE NOTE, ON SECTION IN SHEET L-1A, THE PROJECTION
 MEASURES 3 FEET.
  
 BALCONY PROJECTION IN SECTION REVISED TO 3 FEET.
  
 Z 03.23.23 ??? SATISFIED.
  
 ??? AS SHOWN ON WALK-UP GARDEN SECTION, PLEASE CONSIDER
 THE USE OF A FENCE INSTEAD OF A WALL SO PEDESTRIANS ON
 SIDEWALK CAN SEE VEGETATED AREAS.
  
 WE WILL EXPLORE, PRIOR TO DAC SUBMITTAL, INCORPORATING
 MORE TRANSPARENCY FOR THE WALL UP GARDENS, WITH LOWER
 WALLS AND/OR METAL RAILING.
  
 Z 03.23.23 ??? ACKNOWLEDGED.
  
 ??? NOTE, SHADING SYSTEMS SHOULD NOT AFFECT TREES
 CANOPY ON OPEN SPACES.
  
 SHADING SYSTEMS ADJUSTED TO CLEAR CANOPIES.
  
 Z 03.23.23 ??? PARTIALLY SATISFIED. COURTYARD FACING
 ROSEMARY AVE HAS JAPANESE FERN TREES WITH A 12???
 HEIGHT, THE DRAWINGS SHOW THAT THE OVERHEAD COVER (MIN.
 10% REQUIRED) MIGHT LOWER IMPACTING THE TREES. PLEASE
 REVISE.
  
 NOTE, ON SHEET A1.4B, SOME AREAS OUTSIDE THE PRIVATE
 OPEN SPACE DOTTED LINE ARE NOT SHADED.
  
 HATCH GRAPHICS ADJUSTED ON SHEET A1.4B.
  
 Z 03.23.23 ??? SATISFIED.
  
  
 5. ON SHEET A1.6, PLEASE CLARIFY WHY THE BUILDING'S
 FACADE DIMENSIONS ARE NOT MATCHING OTHER PLANS,
 EXAMPLE, ON SHEET A1.0 AND A1.5, THE NORTH BUILDING
 FRONTAGE IS 150FT. PLEASE ALSO REVIEW, SEC. 94-109,
 FIGURE IV-33 TO SEE TRANSPARENCY SAMPLE CALCULATION.
  
 BUILDING FA??ADE DIMENSIONS UPDATED.
  
 Z 03.15.23 ???NOT SATISFIED. ON SHEET A1.6:
 ??? ON TABLE, REQUIRED SF DOES NOT MATCH THE DIMENSIONS
 ??? GARAGE ENTRANCES CANNOT BE COUNTED TOWARDS
 TRANSPARENCY CALCULATIONS. ENCLOSED NON-ACTIVE USE CAN
 BE EXCLUDE FROM TRANSPARENCY CALCULATIONS AS IT IS NOT
 TECHNICALLY A ???STOREFRONT???. HOWEVER FOR ENCLOSED
 NON-ACTIVE USE FACADES, PLEASE PROVIDE AN ARCHITECTURAL
 TREATMENT (SEE SEC. 94-109, TABLE IV-4).
  
 DIAGRAMS REVISED TO INCLUDE ONLY ???STOREFRONT???
 AREAS. NON-ACTIVE USE AREAS HAVE BEEN IMPROVED TO
 INCORPORATE ARTICULATION AND RHYTHM AND SHOW VARIATION
 IN COLOR.
  
 Z 03.23.23 ??? SATISFIED.
  
 6. PLEASE EXPLAIN WHAT IS THE 'MARKET ROOM' ON THE
 NORTH BUILDING.
 THE MARKET ROOM WILL BE A SMALL AMENITY SPACE FOR
 SNACKS, COFFEE AND VENDING MACHINES. IT WILL BE
 SELF-SERVICE FOR RESIDENTS ONLY.
  
 Z 03.15.23 ??? SATISFIED. PLEASE MAKE SURE TO EXPLAIN
 IN YOUR JUSTIFICATION LETTER.
  
  
  
 PARKING
  
 1. PLEASE NOTE, AS PER SEC. 94-111 (C) IN THOSE CASES
 WHERE THE SIDE OF ANY STALL IS ADJACENT TO A WALL,
 FENCE, BUILDING, OR OTHER PHYSICAL OBSTRUCTION, THE
 STALL WIDTHS SHALL BE INCREASED BY A MINIMUM OF ONE
 FOOT. WHERE THERE IS AN OBSTRUCTION ON BOTH SIDES OF
 THE STALL, THE STALL WIDTHS SHALL BE INCREASED BY A
 MINIMUM OF TWO FEET. ON A2.2 SHEET, TANDEM PARKING
 SPACES LOCATED ON THE SOUTHEAST OF THE PARKING GARAGE
 IN THE SOUTH BUILDING ARE SHOWING AGAINST WALLS
 ENCLOSING STAIRS.
  
 THE TWO AFFECTED TANDEM SPACES HAVE BEEN REMOVED.
  
 Z 03.15.23 ??? SATISFIED
  
 2. PLEASE PROVIDE ADA RAMPS SHOWING SLOPE RATIO AND
 DIMENSIONS. PLEASE MAKE SURE CHANGES ARE REFLECTED ON
 ALL PLANS.
  
 DIMENSIONS AND SLOPE ADDED TO ADA RAMPS.
  
 Z 03.15.23 ??? SATISFIED
  
  
 3. PLEASE CLARIFY IF THE PARKING GARAGE GATES ARE NO
 LONGER PROPOSED AND PARKING LOTS ARE ACCESSIBLE 24/7.
 AND, WHAT SECURITY MEASURES WILL BE PROPOSED FOR
 OPERATIONS?
  
 PARKING ENTRANCES HAVE BEEN REVISED TO SHOW ROLL-UP
 ACCESS GATES.
  
 Z 03.15.23 ??? SATISFIED
  
  
 4. PER SEC. 94-111, ALL PARKING STRUCTURE ENTRANCES
 FACING A STREET FRONTAGE SHALL BE REQUIRED TO TREAT THE
 INTERIOR PORTION OF THE GARAGE ENTRY TO A DEPTH OF AT
 LEAST 20 FEET FROM THE BUILDING FACADE. TREATMENT MAY
 INCLUDE, BUT SHALL NOT BE LIMITED TO, STUCCO OR
 PLASTER, FINISHED AND PAINTED COMPARABLE TO A HABITABLE
 SPACE. ALL MECHANICAL, ELECTRICAL, AND PLUMBING SYSTEMS
 SHALL BE COVERED OR SCREENED.
  
 PARKING ENTRANCES WILL BE TREATED WITH SCORED STUCCO,
 PAINTED TO MATCH ADJACENT ACTIVE USE AREAS. NOTE ALSO
 ADDED TO SITE PLAN INDICATING EXTENT OF WALL TREATMENT.
  
 Z 03.15.23 ??? SATISFIED
  
  
  
 STREETSCAPE AND LANDSCAPE
  
 1. OPEN SPACE DIAGRAMS DO NOT MATCH LANDSCAPE PLANS AND
 WE ARE UNABLE TO DETERMINE ON WHETHER THESE SPACES MEET
 THE LANDSCAPE AND OPEN SPACE REQUIREMENTS. PLEASE NOTE,
 LOADING AREAS AND TRAVEL ROUTES CANNOT GO OVER
 LANDSCAPE, TREES, OR SIDEWALKS. SEE ALSO ZONING DATA
 AND DIAGRAMS COMMENT #4.
  
 LANDSCAPE LAYOUT UPDATED ON SITE PLAN. OPEN SPACE
 DIAGRAMS UPDATED TO SHOW LANDSCAPE LAYOUT.
  
 Z 03.15.23 ??? SATISFIED. PLEASE NOTE, ON ANY PLAN
 SUBMITTED AFTER 3.10.23, PLEASE MAKE SURE TO ADD
 REVISION INFO ON THE TABLE (NO., DATE, REVISIONS).
 PLEASE REVISE SHEET L-2 AND A1.4B.
  
 2. ON SHEET A1.0, EXISTING CROSSING ON N ROSEMARY AND
 4TH ST DOES NOT MEET SIDEWALK. CROSSWALK GRAPHICS
 REVISED TO SHOW CONNECTION TO SIDEWALK.
  
 Z 03.15.23 ??? NOT SATISFIED. CROSSWALKS SHOULD MATCH
 SIDEWALK ON ROSEMARY AVE ON ROSEMARY AVE AND 3RD
 STREET, SEE BELOW SKETCH:
  
 CROSSWALKS UPDATED TO MATCH SIDEWALK.
  
 Z 03.23.23 ??? SATISFIED.
  
  
 3. PLEASE NOTE ON ENGINEERING PLANS YOU ARE SHOWING
 CURB RAMPS ON CROSSINGS AND DRIVEWAYS, PLEASE MAKE SURE
 TO ADD THOSE TO THE SITE PLAN.
 CURB CUTS AND CROSSING ADDED TO SITE PLAN
  
  
 Z 03.15.23 ??? NOT SATISFIED. ON ACCESS TO PARKING
 GARAGES, SIDEWALKS AND LANDSCAPE WERE REMOVED. AND, L-1
 AND L-3 DO NOT MATCH ARCH OR CIVIL PLANS. AS PER CODE,
 CURB CUTS, PARKING ENTRANCES, EXITS, AND DRIVEWAYS
 SHALL NOT BE WIDER THAN 25 FEET AS MEASURED PARALLEL TO
 THE STREET AT THE CURB. PLEASE REVISE SITE PLAN AND ALL
 APPLICABLE PLANS.
  
 ENTRANCES TO GARAGE REVISED SHOW SOW CURBS AND
 LANDSCAPING.
  
 Z 03.23.23 ??? SATISFIED.
  
 4. PLEASE PROVIDE DETAILS ON THE TYPE OF PAVEMENT
 TREATMENT ON CROSSINGS, WALKWAYS, OPEN SPACES, ETC.,
 SUCH AS STAMP CONCRETE, PAVERS, ETC.
  
 SIDEWALKS AND OPEN SPACES WILL BE CONCRETE PAVERS. SEE
 THE LANDSCAPE PLAN AND SITE PLAN FOR NOTES.
  
 Z 03.15.23 ??? NOT SATISFIED. PLEASE ADD LABELS FOR
 SIDEWALK, OPEN SPACES (COURTYARD, WALKUP GARDENS,
 TERRACES), AND LOBBY ENTRANCES PAVEMENT TREATMENT IF
 DIFFERENT FROM CONCRETE PAVERS. AS OF NOW, AREAS HAVE
 DIFFERENT HATCHING AND COLORS THAT COULD INDICATE
 DIFFERENT PAVEMENT MATERIALS.
  
 LABELS UPDATED TO SHOW CONCRETE PAVERS FOR SIDEWALKS,
 PUBLIC OPEN SPACES, AND ENTRANCES/WALK-UP GARDENS. EACH
 COLOR ON THE SITE PLAN REPRESENTS A DIFFERENT CONCRETE
 PAVING COLOR/SIZE/PATTERN.
  
 Z 03.23.23 ??? SATISFIED.
  
 5. PLEASE SHOW LIGHTING POLES ON SITE PLAN AS PROPOSED
 IN YOUR PHOTOMETRIC PLANS E1. PLEASE NOTE, YOU WILL
 NEED TO UPDATE YOUR PHOTOMETRIC PLANS BASED ON CHANGES.
  
 PHOTOMETRIC PLANS HAVE BEEN UPDATED TO REFLECT CURRENT
 SITE PLAN. LIGHT POLES ARE SHOWN ON SITE PLAN SHEET
 A1.0.
  
 Z 03.15.23 ??? SATISFIED. MAKE SURE YOU LABEL THE LIGHT
 POLES ON SITE PLAN.
  
  
  
 ELEVATIONS
  
 1. PLEASE CLARIFY IF THE SCREENING ON THE BRIDGE IS
 DIFFERENT ON BOTH FACADES, NORTH AND SOUTH, AS SHOWN ON
 ELEVATIONS. ALSO CLARIFY, IF COLUMNS ON BRIDGE ARE
 DIFFERENT IN SIZE; ON THE WEST ELEVATION, COLUMNS LOOK
 WIDER AND PAINTED BLUE, ON EAST ELEVATION, COLUMNS AND
 ARE THINNER AND PAINTED WHITE.
  
 BRIDGE SCREENING HAS BEEN REVISED TO SHOW WIDE COLUMNS,
 PAINTED BLUE, ON BOTH SIDES.
  
 Z 03.15.23 ??? SATISFIED.
  
 2. PLEASE MAKE SURE TO ALSO POINT OUT PILASTERS ON
 SHEET A3.2A OR ANY OTHER DECORATIVE TREATMENT PROPOSED
 ON FACADES. AND, PLEASE ADD METAL RAILINGS DETAIL.
  
 SAMPLE IMAGES ADDED FOR PILASTERS AND METAL RAILINGS.
  
 Z 03.15.23 ??? NOT SATISFIED. SEE COMMENT ZONING DATA
 AND DIAGRAMS #5, 3RD STREET AND RAILROAD ELEVATIONS
 ENCLOSING NON-ACTIVE USE. AND, PLEASE NOTE, FOR THE DAC
 PRESENTATION ELEVATIONS AND RENDERINGS WILL NEED TO BE
 CLEANED UP.
  
 ELEVATIONS UPDATED TO SHOW ARCHITECTURAL TREATMENT FOR
 NON-ACTIVE USE FACADES.
  
 RENDERINGS/ELEVATIONS WILL BE CLEANED UP FOR DAC
 PRESENTATION.
  
 Z 03.23.23 ??? SATISFIED.
  
 3. PLEASE NOTE, SOME DOORS ON ELEVATIONS DO NOT MEET
 THE SIDEWALK LEVEL AND HAVE NOT STEPS. SEE EAST
 ELEVATION CLOSER TO THE NORTH AND ADD ELEVATION LEVEL
 TO SIDEWALKS.
  
 EAST ELEVATION REVISED TO SHOW CORRECT DOOR ELEVATIONS
 AND/OR STEPS.
  
 Z 03.15.23 ??? SATISFIED.
  
  
 SECTIONS
  
 1. PLEASE ADD ELEVATION LEVELS TO SIDEWALKS. SPOT
 ELEVATIONS ADDED.
  
 Z 03.15.23 ??? SATISFIED.
  
 2. ON SHEET A4.1, SECTION A, SOME STAIRS ON LOBBIES ARE
 NOT MEETING THE SIDEWALK LEVELS. SECTION GRAPHICS
 UPDATED.
  
 Z 03.15.23 ??? SATISFIED.
  
 3. ON SHEET A4.2, SECTION C DOES NOT MATCH FLOOR PLAN
 AS PARKING CLOSER TO THE WEST IS AT 6FT LEVEL. IN
 ADDITION, THE MAIL ROOM SEEMS TO BE CONNECTED TO THE
 PACKAGE ROOM AND MAIL ROOM LOOKS LIKE IT IS AT 6FT
 LEVEL AND PACKAGE ROOM AT 3FT LEVEL. AND, UNITS ON
 SECTION ARE NOT AT 6FT LEVEL AS SHOWN ON FLOOR PLANS.
  
 YES, MAIL ROOM ACCESS IS CONNECTED TO PACKAGE ROOM.
 PACKAGE ROOM ACCESS HAS BEEN UPDATED TO SHOW STEPS DOWN
 TO LOWER LEVEL. SECTION GRAPHICS UPDATED TO SHOW UNITS
 ON ELEV +6???.
  
 Z 03.15.23 ??? SATISFIED.
  
 4. ON SHEET A4.1 SECTION B AND SHEET A3.2, SOUTH
 ELEVATION- 4TH ST. PLEASE EXPLAIN HOW THESE MAIN
 ENTRANCES TO THE BUILDINGS ARE HIGHLIGHTED WITH THE
 DESIGN. PERHAPS MORE TRANSPARENCY CAN BE ADDED OR USE
 OF DIFFERENT MATERIALS OR COLORS. AS WELL AS
 LANDSCAPING OR HARDSCAPE TO ELEVATE THE DESIGN.
  
 LOBBY ENTRANCES UPDATED TO SHOW MORE GLAZING ON THE
 FA??ADE AS WELL AS ACCENT COLORS AND STUCCO FRAMING
 DETAILS.
  
 Z 03.15.23 ??? SATISFIED.
  
  
  
 RENDERS
  
 1. PLEASE MAKE SURE RENDERS MATCH LANDSCAPING AND
 STREETSCAPE. RENDERED VIEWS UPDATED.
  
 Z 03.15.23 ??? PARTIALLY SATISFIED. I DO NOT THINK
 RENDERS SHOW ALL LANDSCAPING, SPECIALLY VEGETATED AREAS
 ON OPEN SPACES AND LANDSCAPE STRIP ADJACENT TO THE
 SIDEWALKS.
  
 Z 03.23.23 ??? SATISFIED. MAKE SURE PROPOSED
 LANDSCAPING IS REFLECTED ON RENDERS.
  
  
 CONDITIONS OF APPROVAL:
 ??? PRIOR TO FINAL SITE PLAN APPROVAL, THE APPLICANT
 SHALL SUBMIT FINAL SET OF PLANS.
 ??? ALL TANDEM PARKING SPACES WITHOUT LIFTS PROVIDED IN
 THE PARKING STRUCTURE SHALL BE DEDICATED TO RESIDENTIAL
 USE ONLY AND TO THE SAME RESIDENTIAL UNIT. THE
 DEDICATION OF TANDEM PARKING SPACES TO THE SAME
 RESIDENTIAL UNIT SHALL BE ESTABLISHED AND RECORDED IN A
 RESTRICTIVE COVENANT ON CITY APPROVED FORMS AND
 RECORDED IN THE PUBLIC RECORDS PRIOR TO THE ISSUANCE OF
 FINAL C.O.
 ??? TREES ADJACENT TO VISIBILITY TRIANGLES WILL HAVE AN
 8??? CLEAR TRUNK.
 ??? THE PROJECT, AS IT INCLUDES RESIDENTIAL
 MICRO-UNITS, WILL CONTRIBUTE A TROLLEY FEE PER UNIT PER
 MONTH TO SUPPORT THE OPERATION OF THE CITY'S TROLLEY
 SYSTEM, AS ESTABLISHED BY RESOLUTION OF THE CITY
 COMMISSION FROM TIME TO TIME.
 ??? THE APPLICANT, SUCCESSORS AND ASSIGNS SHALL BE
 RESPONSIBLE FOR THE PERMITTING AND INSTALLATION OF
 MICRO MOBILITY/BIKE SHARE STATION APPROVED WITH THIS
 PETITION. INSTALLATION SHALL BE COMPLETED PRIOR T.C.O.
 ??? ALL PARKING STRUCTURE ENTRANCES FACING A STREET
 FRONTAGE SHALL BE REQUIRED TO TREAT THE INTERIOR
 PORTION OF THE GARAGE ENTRY TO A DEPTH OF AT LEAST 20
 FEET FROM THE BUILDING FA??ADE. TREATMENT MAY INCLUDE,
 BUT SHALL NOT BE LIMITED TO, STUCCO OR PLASTER,
 FINISHED AND PAINTED COMPARABLE TO A HABITABLE SPACE.
 ALL MECHANICAL, ELECTRICAL, AND PLUMBING SYSTEMS SHALL
 BE COVERED OR SCREENED.
  

Review Stop Z ZONING
Rev No 4 Status F Date 03-02-2023 Cont ID  
Sent By cibaven Date 03-02-2023 Time 15:12 Rev Time 0.00
Received By cibaven Date 03-02-2023 Time 15:09 Sent To  
Notes
2023-03-02 15:09:39ZONING AND PLANNING
 PROJECT: SOLESTE - 410 N. ROSEMARY AVE.
 DATE: 03.01.23
 CONTACT: CLAUDIA IBAVEN, CITY URBAN DESIGNER, AT
 561-822-1402 OR VIA [email protected].
 I HAVE REVIEWED THE ABOVE REFERENCED PETITION AND
 PROVIDE THE FOLLOWING COMMENTS:
  
 ZONING DATA AND DIAGRAMS
 1. ON SHEET A1.5, ACTIVE USE: PLEASE REVISE BOTH
 DIMENSIONS AND TABLE CALCULATIONS BASED ON THE
 FOLLOWING:
 - FACING N ROSEMARY AVE, THE DIMENSIONS OF THE
 'BUILDABLE LOT FRONTAGE' OF THE NORTH BUILDING SHOULD
 BE FROM THE SETBACK TO THE SOUTH END OF THE OPEN SPACE.
 ACTIVE USE DIMENSION (179FT) IS NOT SHOWN ON THE TABLE.
 - FACING N ROSEMARY AVE, THE DIMENSIONS OF THE
 'BUILDABLE LOT FRONTAGE' OF THE SOUTH BUILDING SHOULD
 BE FROM THE SETBACK TO NORTH END OF OPEN SPACE.
 COURTYARD SHOULD BE INCLUDED AS ACTIVE USE.
 - FACING W RAILROAD AVE, THE DIMENSION OF 'BUILDABLE
 LOT FRONTAGE' OF 196FT AND 'ACTIVE USE' OF 77FT DO NOT
 MATCH THE TABLE.
 - FACING 3RD STREET, PLEASE NOTE ENCLOSED STAIRS DO NOT
 COUNT AS ACTIVE USE, PLEASE EXCLUDE FROM DIMENSIONS AND
 CALCULATIONS.
  
 2. ON SHEET A1.5, PLANAR BREAKS: THE COURTYARD ALSO IS
 A PLANAR BREAK, PLEASE INCLUDE IN YOUR CALCULATIONS.
  
 3. ON SHEET A1.5, HORIZONTAL PROJECTIONS: THERE ARE
 DOTTED LINES THAT SEEM TO BE HORIZONTAL PROJECTIONS BUT
 ARE NOT COUNTED AS SUCH, PLEASE REVIEW. AND, PLEASE
 MAKE SURE HORIZONTAL PROJECTIONS MATCH OTHER PLANS AND
 RENDERINGS.
  
 4. ON SHEET A1.4 - OPEN SPACE: PLEASE NOTE, THERE IS NO
 BREAKDOWN SHOWING WHERE THE 2,270SQ.FT. OF SEMI-OPEN
 SPACE IS COMING FROM. IN ADDITION, THERE ARE SOME
 WALK-UP GARDENS THAT LOOK DIFFERENT IN CONFIGURATION
 FROM THE SAMPLES. AND SAMPLES ARE SHOWING OVERHEAD
 COVERAGES DIFFERENT FROM FLOOR PLANS AND RENDERINGS.
  
 5. ON SHEET A1.6, PLEASE CLARIFY WHY THE BUILDING'S
 FACADE DIMENSIONS ARE NOT MATCHING OTHER PLANS,
 EXAMPLE, ON SHEET A1.0 AND A1.5, THE NORTH BUILDING
 FRONTAGE IS 150FT. PLEASE ALSO REVIEW, SEC. 94-109,
 FIGURE IV-33 TO SEE TRANSPARENCY SAMPLE CALCULATION.
  
 6. PLEASE EXPLAIN WHAT IS THE 'MARKET ROOM' ON THE
 NORTH BUILDING.
  
  
 PARKING
 1. PLEASE NOTE, AS PER SEC. 94-111 (C) IN THOSE CASES
 WHERE THE SIDE OF ANY STALL IS ADJACENT TO A WALL,
 FENCE, BUILDING, OR OTHER PHYSICAL OBSTRUCTION, THE
 STALL WIDTHS SHALL BE INCREASED BY A MINIMUM OF ONE
 FOOT. WHERE THERE IS AN OBSTRUCTION ON BOTH SIDES OF
 THE STALL, THE STALL WIDTHS SHALL BE INCREASED BY A
 MINIMUM OF TWO FEET. ON A2.2 SHEET, TANDEM PARKING
 SPACES LOCATED ON THE SOUTHEAST OF THE PARKING GARAGE
 IN THE SOUTH BUILDING ARE SHOWING AGAINST WALLS
 ENCLOSING STAIRS.
  
 2. PLEASE PROVIDE ADA RAMPS SHOWING SLOPE RATIO AND
 DIMENSIONS. PLEASE MAKE SURE CHANGES ARE REFLECTED ON
 ALL PLANS.
  
 3. PLEASE CLARIFY IF THE PARKING GARAGE GATES ARE NO
 LONGER PROPOSED AND PARKING LOTS ARE ACCESSIBLE 24/7.
 AND, WHAT SECURITY MEASURES WILL BE PROPOSED FOR
 OPERATIONS?
  
 4. PER SEC. 94-111, ALL PARKING STRUCTURE ENTRANCES
 FACING A STREET FRONTAGE SHALL BE REQUIRED TO TREAT THE
 INTERIOR PORTION OF THE GARAGE ENTRY TO A DEPTH OF AT
 LEAST 20 FEET FROM THE BUILDING FACADE. TREATMENT MAY
 INCLUDE, BUT SHALL NOT BE LIMITED TO, STUCCO OR
 PLASTER, FINISHED AND PAINTED COMPARABLE TO A HABITABLE
 SPACE. ALL MECHANICAL, ELECTRICAL, AND PLUMBING SYSTEMS
 SHALL BE COVERED OR SCREENED.
  
  
  
 STREETSCAPE AND LANDSCAPE
 1. OPEN SPACE DIAGRAMS DO NOT MATCH LANDSCAPE PLANS AND
 WE ARE UNABLE TO DETERMINE ON WHETHER THESE SPACES MEET
 THE LANDSCAPE AND OPEN SPACE REQUIREMENTS. PLEASE NOTE,
 LOADING AREAS AND TRAVEL ROUTES CANNOT GO OVER
 LANDSCAPE, TREES, OR SIDEWALKS. SEE ALSO ZONING DATA
 AND DIAGRAMS COMMENT #4.
  
 2. ON SHEET A1.0, EXISTING CROSSING ON N ROSEMARY AND
 4TH ST DOES NOT MEET SIDEWALK.
  
 3. PLEASE NOTE ON ENGINEERING PLANS YOU ARE SHOWING
 CURB RAMPS ON CROSSINGS AND DRIVEWAYS, PLEASE MAKE SURE
 TO ADD THOSE TO THE SITE PLAN.
  
 4. PLEASE PROVIDE DETAILS ON THE TYPE OF PAVEMENT
 TREATMENT ON CROSSINGS, WALKWAYS, OPEN SPACES, ETC.,
 SUCH AS STAMP CONCRETE, PAVERS, ETC.
  
 5. PLEASE SHOW LIGHTING POLES ON SITE PLAN AS PROPOSED
 IN YOUR PHOTOMETRIC PLANS E1. PLEASE NOTE, YOU WILL
 NEED TO UPDATE YOUR PHOTOMETRIC PLANS BASED ON CHANGES.
  
  
 ELEVATIONS
 1. PLEASE CLARIFY IF THE SCREENING ON THE BRIDGE IS
 DIFFERENT ON BOTH FACADES, NORTH AND SOUTH, AS SHOWN ON
 ELEVATIONS. ALSO CLARIFY, IF COLUMNS ON BRIDGE ARE
 DIFFERENT IN SIZE; ON THE WEST ELEVATION, COLUMNS LOOK
 WIDER AND PAINTED BLUE, ON EAST ELEVATION, COLUMNS AND
 ARE THINNER AND PAINTED WHITE.
  
 2. PLEASE MAKE SURE TO ALSO POINT OUT PILASTERS ON
 SHEET A3.2A OR ANY OTHER DECORATIVE TREATMENT PROPOSED
 ON FACADES. AND, PLEASE ADD METAL RAILINGS DETAIL.
  
 3. PLEASE NOTE, SOME DOORS ON ELEVATIONS DO NOT MEET
 THE SIDEWALK LEVEL AND HAVE NOT STEPS. SEE EAST
 ELEVATION CLOSER TO THE NORTH AND ADD ELEVATION LEVEL
 TO SIDEWALKS.
  
  
 SECTIONS
 1. PLEASE ADD ELEVATION LEVELS TO SIDEWALKS.
  
 2. ON SHEET A4.1, SECTION A, SOME STAIRS ON LOBBIES ARE
 NOT MEETING THE SIDEWALK LEVELS.
  
 3. ON SHEET A4.2, SECTION C DOES NOT MATCH FLOOR PLAN
 AS PARKING CLOSER TO THE WEST IS AT 6FT LEVEL. IN
 ADDITION, THE MAIL ROOM SEEMS TO BE CONNECTED TO THE
 PACKAGE ROOM AND MAIL ROOM LOOKS LIKE IT IS AT 6FT
 LEVEL AND PACKAGE ROOM AT 3FT LEVEL. AND, UNITS ON
 SECTION ARE NOT AT 6FT LEVEL AS SHOWN ON FLOOR PLANS.
  
 4. ON SHEET A4.1 SECTION B AND SHEET A3.2, SOUTH
 ELEVATION- 4TH ST. PLEASE EXPLAIN HOW THESE MAIN
 ENTRANCES TO THE BUILDINGS ARE HIGHLIGHTED WITH THE
 DESIGN. PERHAPS MORE TRANSPARENCY CAN BE ADDED OR USE
 OF DIFFERENT MATERIALS OR COLORS. AS WELL AS
 LANDSCAPING OR HARDSCAPE TO ELEVATE THE DESIGN.
  
  
 RENDERS
 1. PLEASE MAKE SURE RENDERS MATCH LANDSCAPING AND
 STREETSCAPE.
  
  
 OTHER COMMENTS:
 PLEASE NOTE, AS PER SEC. 94-54 (A)(1), THE APPLICANT
 SHALL ADDRESS ANY COMMENTS OF THE PPRC AND SUBMIT A
 REVISED APPLICATION WITHIN 60 DAYS OF THE DATE OF SUCH
 COMMENTS. FAILURE TO MAKE THE REQUIRED SUBMITTALS
 WITHIN THE 60-DAY DEADLINE WILL DEEM THE APPLICATION AS
 WITHDRAWN. AT LEAST 15 DAYS PRIOR TO THE EXPIRATION OF
 THE 60-DAY REVISION PERIOD, THE APPLICANT MAY REQUEST A
 30-DAY EXTENSION. NO FURTHER EXTENSION REQUEST IS
 PERMITTED. COMMENTS RELATING TO REVISED APPLICATIONS
 SHALL BE ADDRESSED WITHIN 30 DAYS OF THE DATE OF SUCH
 COMMENTS.
  
 WHEN RESUBMITTING, WRITTEN RESPONSES TO COMMENTS NEED
 TO BE PROVIDED AS WELL AS A MINIMUM OF TWO (2) PAPER
 COPIES AND AN ELECTRONIC COPY IN .PNG/.PDF FORMAT OF
 ALL PLANS AND ALL DOCUMENTATION REQUIRED IN THE
 APPLICATION. PLEASE NOTE THAT CHANGES ON THE
 RESUBMITTED PLANS OR THE SUBMITTAL OF INFORMATION/PLANS
 TO ADDRESS THE COMMENTS MAY RESULT IN ADDITIONAL
 COMMENTS.
  
 LASTLY, YOU WERE PERMITTED ONE (1) RESUBMITTAL AT NO
 ADDITIONAL COST. AS PREVIOUSLY ISSUED COMMENTS CONTINUE
 TO NOT BE SUFFICIENTLY ADDRESSED, THE APPLICANT WILL BE
 ASSESSED A RESUBMITTAL FEE. SUCH FEE WILL BE 20% OF THE
 ORIGINAL APPLICATION FEE.
  

Review Stop Z ZONING
Rev No 3 Status F Date 01-30-2023 Cont ID  
Sent By cibaven Date 01-30-2023 Time 14:21 Rev Time 0.00
Received By cibaven Date 01-30-2023 Time 14:21 Sent To  
Notes
2023-01-30 14:09:47ZONING AND PLANNING
 PROJECT: SOLESTE ??? 410 N. ROSEMARY AVE.
 DATE: JANUARY 27, 2023
 CONTACT: CLAUDIA IBAVEN, CITY URBAN DESIGNER, AT
 561-822-1402 OR VIA [email protected].
 I HAVE REVIEWED THE ABOVE REFERENCED PETITION AND
 PROVIDE THE FOLLOWING COMMENTS:
  
 GENERAL COMMENTS:
 PER SEC. 94-39 (J)(4) AND SEC. 94-54 (B)(3), THE
 PROPOSED DEVELOPMENT WILL NEED TO MEET PROCEDURES OF
 NOTICES OF PUBLIC MEETINGS.
  
 THE PROJECT IS SUBJECT TO THE CITY OF WPB'S ART LIFE
 ASSESSMENT. PLEASE PROVIDE INFORMATION ON HOW THE
 PROPOSED DEVELOPMENT WILL MEET THIS REQUIREMENT.
  
 AS PART OF THE APPLICATION CHECK LIST, ALL REQUIRED
 DOCUMENTS WILL NEED TO BE UPDATED AND REVISED IN EACH
 RESUBMITTAL. IF A DOCUMENT DOES NOT NEED TO BE REVISED
 OR NEED TO BE UPDATED, PLEASE LIST THE DOCUMENT ON THE
 WRITTEN RESPONSE. SEE FOLLOWING DOCUMENTS THAT WILL
 NEED TO BE UPDATED/REVISE:
 - PLEASE REVISE PROJECT DATA SHEET, ON CURRENT ZONING
 EAST AND WEST ROWS.
 - PLEASE UPDATE JUSTIFICATION LETTER DATED ON
 08.04.2022 AND ADD TO RESUBMITTAL.
 - PLEASE UPDATE YOUR TRAFFIC PERFORMANCE STANDARDS
 LETTER FROM PALM BEACH COUNTY TO REFLECT ANY NEW
 DRIVEWAYS AND UNITS IN THE PROPOSED DEVELOPMENT.
  
  
 IF YOU WOULD LIKE TO RECEIVE A WORD DOC OF THE ZONING
 AND PLANNING COMMENTS, PLEASE CONTACT CLAUDIA IBAVEN
 VIA EMAIL. PLEASE NOTE, I ADDED A 'Z' AT THE BEGINNING
 OF A COMMENT COMING FROM ZONING OR 'A' AT THE BEGINNING
 OF A COMMENT COMING FROM THE APPLICANT.
  
  
 COMMENT 1:
  
 Z - ACTIVE USE: PLEASE NOTE THAT ACTIVE USES ARE
 REGULATED AS A PERCENTAGE OF THE BUILDABLE LOT
 FRONTAGE, NOT THE BUILDING FRONTAGE. PLEASE ADJUST
 CALCULATIONS ACCORDINGLY. THE PERCENTAGE SHOULD BE 80%
 OF THE ENTIRE N ROSEMARY AVE. PROPERTY LINE (60% FOR
 LINERS 2-5), 30% OF THE 3RD ST. PROPERTY LINE, AND THEN
 30% OF THE W. RAILROAD AVE. PROPERTY LINE.
  
 A- SEE SHEET A1.5 FOR ACTIVE USE DIAGRAMS AND
 CALCULATIONS.
  
 Z 11.17.22 - PARTIALLY SATISFIED.
 TABLE ON SHEET A0.2 DIFFERS FROM CALCULATIONS ON A.1.5.
 A1.5 IS LABELED CORRECTLY. PLEASE ADJUST.
  
 A - RESPONSE: SHEET A0.2 HAS BEEN ADJUSTED TO REFERENCE
 CALCULATIONS ON SHEET A1.5.
  
 Z 01.27.23 - NOT SATISFIED. AS PREVIOUSLY MENTIONED,
 THE PERCENTAGE OF ACTIVE USE WILL BE CALCULATED FROM
 THE BUILDABLE LOT FRONTAGE AND NOT THE BUILDING
 FRONTAGE. PLEASE REVISE 'MINIMUM ACTIVE USE' TABLE ON
 SHEET A1.05, MAKE SURE ALL DIMENSIONS OF BUILDING LOT
 FRONTAGE AND OTHERS ARE ON THE DRAWINGS. PLEASE ALSO
 ADD CALCULATIONS FOR 4TH STREET FACADES. FOR MORE INFO
 ABOUT THE DEFINITION OF 'ACTIVE USE' OR 'BUILDABLE LOT
 FRONTAGE' AND WHAT CAN BE INCLUDED IN CALCULATIONS SEE
 SEC. 94-109, AND FIGURE IV-14 SHOWING BUILDABLE LOT
 FRONTAGE.
  
  
 COMMENT 2:
 Z - PLEASE PROVIDE OWNERS CONSENT OR PROOF OF AGREEMENT
 BETWEEN THE NEIGHBORING PROPERTY OWNER OF 411 W
 RAILROAD AVE. TO ALLOW FOR THE EXTENSION OF 4TH ST.
 OVER THEIR PROPERTY.
  
 A- THE RECORDED EASEMENT PROVIDING AUTHORITY TO MAKE
 THESE IMPROVEMENTS ARE INCLUDED WITHIN THIS SUBMITTAL.
 NO ADDITIONAL CONSENT IS REQUIRED FROM THE ADJACENT
 PROPERTY OWNERS AS THE EASEMENT ALLOWS EITHER PARTY THE
 AUTHORITY TO MAKE THE CONTEMPLATED IMPROVEMENTS DENOTED
 WITHIN THE EASEMENT ITSELF.
  
 Z 11.17.22 - PARTIALLY SATISFIED.
 EASEMENT AGREE PROVIDED. EASEMENT EXHIBIT B SHOWS 50 FT
 EASEMENT, PLANS SHOW 60 FEET. SHY THE ADDITIONAL 10 FT?
  
 A - SHEET A1.0 HAS BEEN ADJUSTED TO REFLECT 50 FT
 EASEMENT WIDTH.
  
 Z 01.27.23 - NOT SATISFIED. PLEASE CLARIFY THE CHANGES
 MADE TO SHEET A1.0 COMPARED TO PREVIOUS SUBMITTAL.
 THERE IS NO DIMENSION OR LABEL SHOWING THE 50FT
 EASEMENT. ALSO NOTE, LANDSCAPE AREA IS SHOWING IN
 LANDSCAPE SHEET L-1 WITH LIVE OAKS, PLEASE REVISE A1.0
 TO MATCH L-1.
  
  
 COMMENT 3:
 Z - RADIUS OF THE CURB-CUT OR APRON FOR THE NORTHERN
 SERVICE ACCESS ENCROACHES INTO CITY PROPERTY, PLEASE
 ADJUST.
  
 A - SHEET A1.0 SHOWS REVISED CURB CUT.
  
 Z 11.17.22 - PARTIALLY SATISFIED. ADJUSTMENT MADE,
 HOWEVER PORTION OF CURB CUT RADIUS STILL SHOWN AS PART
 OF ADJACENT PROPERTY ON NORTHERN SERVICE ROAD (WEST
 RAILROAD AVE) AND EASTERN SERVICE ROAD (3RD STREET)
  
 A- SEE SHEET A1.0. SERVICE ROAD RADII HAVE BEEN
 ADJUSTED AS TO NOT ENCROACH INTO ADJACENT PROPERTIES.
  
 Z 01.27.23 - SATISFIED.
  
  
 COMMENT 4:
 Z - THE SERVICE ACCESS ALONG THE SOUTHERN AND NORTHERN
 SIDE OF THE PROPERTY DOES NOT PROVIDE REQUIRED 5 FT.
 LANDSCAPE BUFFER ALONG THE PROPERTY LINE AND TO SCREEN
 THE VEHICULAR USES. SERVICE ROADS WILL HAVE TO BE
 ADJUSTED TO ACCOMMODATE FOR THE BUFFER.
  
 A - PREVIOUS RESPONSE: SHEET A1.0 SHOWS REVISED SERVICE
 ACCESS AND BUFFER.
  
 Z - 11.17.22 - PARTIALLY SATISFIED.
 NORTHERN SERVICE ROAD (ADJACENT TO CITY PROPERTY)
 INCLUDES LIVE OAK, GREEN BUTTONWOOD, AND COCOPLUM
 GROUND COVER WHICH SATISFIES THE LANDSCAPE BUFFER.
 SUGGEST PLANTING HEDGES TO FURTHER SCREEN LOADING
 BAY/OPERATION FROM ROSEMARY AND ADJACENT PROPERTY.
 SOUTHERN SERVICE ROAD (3RD ST.) INDICATES SYNTHETIC
 TURF, THIS DOES NOT SATISFY LANDSCAPE BUFFER
 REQUIREMENTS NOR IS IT PERMITTED IF SEEN FROM THE ROW
 (4TH ST. EXT OR 3RD ST.) PLEASE ADJUST TO INCLUDE REAL
 PLANT MATERIAL AND/OR GROUND COVER.
  
 A - PLEASE, SEE REVISED LANDSCAPE SHEETS.
  
 Z 01.27.23 - PARTIALLY SATISFIED - ON THE SITE PLAN,
 SHEET A1.0, THERE IS THE LABEL 'DOG RUN' BUT ON
 LANDSCAPE SHEET L-01 THERE IS VEGETATION AND TREES,
 PLEASE REVISE. IN ADDITION, TREES SHOULD CONTINUE FROM
 NORTH (4TH STREET) TO SOUTH (3RD ST) ON THE 5FT
 LANDSCAPE BUFFER. LASTLY, MAKE SURE THAT THE SIDEWALK
 ON 3RD STREET IS NOT INTERRUPTED WITH VEGETATION AREAS
 AS SHOWN ON LANDSCAPE SHEET L-1.
  
 COMMENT 5:
 Z - SHEET A0.2, SITE INFORMATION TABLES REQUIRE
 CORRECTIONS:
 - IF LOT AREA IS 108,638; THEN WITH A 2.75 FAR MAXIMUM
 ALLOWED IS 298,755 SF, NOT 298,729 SF.
 - REQUIRED PRIVATE OPEN SPACE AT 25% IS 27,160 SF, NOT
 27,158 SF.
 - CONDITIONAL 50? SETBACK IS FROM ABOVE THE 5TH FLOOR,
 NOT THE 6TH.
 - GBA SHOULD MATCH FAR CALCULATION.
 - PLEASE DOUBLE CHECK ALL CALCULATIONS AND DIMENSIONS
 OR CONSISTENCY ACROSS PLANS.
  
 A- SHEET A0.2 SHOWS REVISED DATA.
  
 Z 11.17.22 - PARTIALLY SATISFIED. TABLE ON SHEET A0.2
 DIFFERS FROM CALCULATIONS ON A1.5. A1.5 IS LABELED
 CORRECTLY PLEASE ADJUST.
  
 A - SHEET A0.2 HAS BEEN ADJUSTED TO REFERENCE
 CALCULATIONS ON SHEET A1.5.
  
 Z 01.27.23 - NOT SATISFIED. CORRECT CALCULATIONS ON
 TABLE 'MINIMUM ACTIVE USE', AS MENTIONED ON COMMENT #1.
  
 IN ADDITION, ON SHEET A1.4, PLEASE ADD A TABLE SHOWING
 TOTALS FOR REQUIRED VS PROPOSED FOR OPEN SPACE
 CALCULATIONS. PRIVATE OPEN SPACE CALCULATIONS ARE
 MISSING. NOTE, 'POOL DECK' IS NOT A TYPE OF PRIVATE
 OPEN SPACE. ON PUBLIC OPEN SPACE TABLES, NOTE THE TYPE.
 FOR INFORMATION ABOUT WHAT IS PERMITTED BY DISTRICT
 CHECK SEC. 94-109, TABLE IV-6, OR CHECK SAME SECTION
 FOR DEFINITIONS OF EACH TYPE. CALCULATIONS WILL NEED TO
 MEET THE REQUIREMENTS OF SEC. 94-109, TABLE IV-7.
  
  
 COMMENT 6:
 Z 11.17.22 - OPEN SPACE REQUIREMENT. PARTIALLY
 SATISFIED (SEE NEW COMMENT 5).
  
 A - SEE NEW COMMENT 5 RESPONSE.
  
 Z 01.27.23 NOT SATISFIED - PLEASE SEE COMMENT NO. 5.
 AND PLEASE SHARE ANY UPDATES ON DISCUSSIONS RELATED TO
 THE PUBLIC ACCESS EASEMENT.
  
 PER SEC. 94-113 (D) (1), PRIVATE SIDEWALKS WHICH SERVE
 AS AN EXTENSION OF THE PUBLIC SIDEWALK SHALL COMPLY
 WITH THE STREETSCAPE REQUIREMENTS, SHALL MATCH THE
 PUBLIC SIDEWALK IN DESIGN AND MATERIAL, AND SHALL
 PROVIDE A SEAMLESS TRANSITION BETWEEN THE TWO. ON 4TH
 (NORTH AND SOUTH SIDEWALKS) STREET PLEASE MAKE SURE YOU
 HAVE A CLEAR SIDEWALK AND STREET TREES ON A LANDSCAPE
 STRIP ADJACENT TO THE CURB. STREET TREES SHOULD BE ON
 4FT PLANTING BEDS, SIDEWALK WIDTH CAN BE A MINIMUM 5
 FT. NOTE, STREET TREES SPACING IS 30FT MAX., SEE MORE
 INFO ON SEC. 94-113 (D) (2) AND MAKE SURE ALL STREET
 TREES MEET THE REQUIREMENT.
  
 NOTE, PLEASE REFLECT ANY CHANGES ON ALL PLANS, AS NOTED
 BEFORE SOME CHANGES IN LANDSCAPE PLANS ARE MISSING ON
 ARCHITECTURAL PLANS.
  
  
 COMMENT 7:
 Z 11.17.22. SATISFIED.
  
  
 COMMENT 8:
 Z - SHEET A1.0 PLEASE PROVIDE ALL CURBCUT WIDTH
 DIMENSIONS ALONG PROPERTY LINE, CANNOT EXCEED 25.
  
 A- SEE SHEET A1.0 FOR CURB CUT DIMENSIONS.
  
 Z 11.17.22 - PARTIALLY SATISFIED MEASUREMENT FOR
 CURBCUT WIDTH IS TO BE TAKEN FROM INTERSECTION OF
 PROPERTY LINE WITH THE CURBCUT, PLEASE ADJUST.
  
 A - SHEET A1.0 HAS BEEN ADJUSTED TO SHOW CURB CUT
 DIMENSIONS AT PROPERTY LINES.
  
 Z 01.27.23 - SATISFIED.
  
  
 COMMENT 9:
 Z - ON SHEET L-1 AND A1.0 STREETSCAPE AND LANDSCAPE
 REQUIREMENTS NOT MET:
 A. STREET TREES ARE REQUIRED TO BE ADJACENT TO THE
 CURB, N ROSEMARY AVENUE SIDE ON FEATURES 5 (EXISTING)
 TREES, REQUIREMENT IS TREES SPACED OUT AT A MAX. OF 30
 FT. ON CENTER; APPROX. 16 STREET TREES REQUIRED ALONG N
 ROSEMARY.
  
 A - ALONG ROSEMARY AVE THE 8' SIDEWALK IS PROPOSED
 ADJACENT TO THE CURB SO THE STREET TREES ARE PROVIDED
 BETWEEN THE WALK AND THE BUILDING AT 30' O.C. THE 5
 EXISTING TREES WILL BE REMOVED. CITY ALSO MENTIONED CRA
 WOULD BE DEVELOPING A STREETSCAPE ALONG ROSEMARY AVE.
 ONCE CRA PLANS ARE FINALIZED THE STREETSCAPE ALONG
 ROSEMARY SHALL BE MODIFIED TO INCORPORATE CRA DESIGN.
  
 Z 11.17.22 - NOT SATISFIED.
 STREET TREES ARE REQUIRED TO BE PLANTED ADJACENT TO THE
 CURB PER SEC. 94-113. CITY STAFF HAS CONFIRMED WITH CRA
 THAT THE APPLICANT IS RESPONSIBLE FOR MEETING THE CITY
 STREETSCAPE REQUIREMENTS WITH THIS PROJECT PROPOSAL, AS
 FUTURE WORK AND DESIGN BY CRA/CITY NOT CONFIRMED.
 APPROX. 16 STREET TREES REQUIRED ALONG N ROSEMARY
 PLEASE ILLUSTRATE STREETSCAPE/LANDSCAPE ELEMENTS
 (STREET TREES, ETC.) WITHIN THE SITE PLAN A1.0
  
 A - PLEASE, SEE REVISED LANDSCAPE SHEETS.
  
 Z 01.27.23 - PARTIALLY SATISFIED. ON N ROSEMARY AVE,
 SOME TREES ARE SPACED OUT MORE THAN 30 FT. PLEASE
 ADJUST.
  
 PLEASE NOTE, ON 4TH STREET SOUTH SIDEWALK GREEN AREAS
 WHERE TREES ARE LOCATED ON THE WEST SIDE OF THE BLOCK
 ARE NOT SHOWING ON A1.0 JUST LIKE IT SHOWS ON L-1. ALSO
 SEE COMMENT NO. 4 AND 6 AS RELATES TO LANDSCAPE.
  
  
 COMMENT 10:
 Z- PLEASE PROVIDE SETBACK LINES ON ALL ELEVATIONS.
  
 A - SEE SHEETS A3.1 AND A3.2 FOR REVISED ELEVATIONS.
  
 Z 11.17.22 - PARTIALLY SATISFIED
 SETBACKS PROVIDED, SHEET A3.1 WEST ELEVATION DOES NOT
 SHOW BRIDGE CONNECTING TWO BUILDINGS.
  
 A - SHEET A3.1 HAS BEEN ADJUSTED TO SHOW BRIDGE.
  
 Z 01.27.23 - SATISFIED.
  
  
 Z - SHEET A3.1 EAST ELEVATION SHOWS OPENINGS THROUGH
 THE 2ND AND 3RD LEVELS, WHAT ARE THESE?
  
 A - SHEET A3.1 HAS BEEN ADJUSTED TO REMOVE OPENINGS IN
 EAST ELEVATION.
  
 Z 01.27.23 - PARTIALLY SATISFIED. ON THE GROUND FLOOR,
 ON THE ENTRANCE OF THE LOADING AREA ON THE NORTH
 BUILDING, THERE IS STILL A BLUE OPENING. IN ADDITION,
 ON THE 4 FLOOR, PARKING LEVEL AREA, IT SEEMS THAT THE
 FACADE ARTICULATION IS NOT FINISH OR MEETING THE OTHER
 BUILDING VOLUME TO THE NORTH.
  
 Z - SHEET A3.2 SOUTH ELEVATION GROUND LEVEL SHOWS
 GREYED OUT PORTION OVER ENTRY. PLEASE REVISE.
  
 A - SHEET A3.2 HAS BEEN ADJUSTED TO REVISE ELEVATION.
 ELEVATION LABELS HAVE ALSO BEEN UPDATED TO REFLECT THE
 CORRECT ORIENTATION.
  
 Z 01.27.23 - PARTIALLY SATISFIED. PERHAPS THE USE OF
 SOLID FILL HATCH AND THE PRINTING IS CAUSING SLIGHTS
 ERRORS ON THE ELEVATIONS, PLEASE SEE ON SOUTH
 ELEVATION, THERE IS A GRAY VOLUME CROSSING THE
 SETBACKS. THERE ARE ALSO SOME DOORS THAT ARE NOT
 MEETING THE GROUND FLOOR AND IT IS NOT CLEAR IF THEY
 HAVE ANY STEPS OR HOW PEDESTRIANS WILL ACCESS THE
 BUILDING. PLEASE REVISE.
  
 Z 01.27.23 - NEW COMMENT: PLEASE PROVIDE MORE
 INFORMATION ON ELEVATIONS DRAWINGS ABOUT FACADE
 MATERIALS AND ARCHITECTURAL TREATMENT DETAILS TO MEET
 FACADE ARTICULATION REQUIREMENTS ON SEC. 94-109, TABLE
 IV-4. NOTED THAT YOU HAVE A1.6 PROVIDING INFORMATION
 ABOUT TRANSPARENCY. AND, A1.5 PROVIDING INFO ABOUT
 PLANAR BREAKS AND HORIZONTAL PROJECTIONS.
  
  
 COMMENT 11:
 Z - PLEASE PROVIDE SEPARATE SHEETS ON FACADE
 ARTICULATION AND HOW THE PROJECT MEETS PLANAR BREAK
 REQUIREMENTS, TRANSPARENCY/FENESTRATION REQUIREMENTS,
 AND PROVIDE ADDITIONAL DETAILS FOR ANY PROJECTIONS,
 SCREENING, OR ARCHITECTURAL FEATURES.
  
 A - SEE SHEETS A1.5 AND A1.6 FOR PLANAR BREAK AND
 TRANSPARENCY DIAGRAMS.
  
 Z 11.17.22 - NOT SATISFIED. CLARIFICATION FOR BUILDING
 FRONTAGES OF 150 FT. OR MORE NO FACADE SHALL EXCEED 60%
 OF FRONTAGE WITHOUT PROVIDING A PLANAR BREAK OF AT
 LEAST 3 FT. IN DEPTH, TOTAL WIDTH OF PLANAR BREAKS
 SHALL BE GREATER THAN OR EQUAL TO 20% OF BUILDING
 FRONTAGE. PLEASE PROVIDE PLANAR BREAK CALLOUTS AND
 DIMENSIONS FOR THE W RAILROAD AVE. SIDE, THE GARAGE
 ENTRY IS STILL PART OF THE OVERALL BUILDING AND PODIUM.
  
 A - PLANAR BREAKS ADDED TO RAILROAD AVENUE AND TABLE
 UPDATED.
  
 Z - WIDTH REQUIREMENTS APPEAR TO BE MET. PLEASE PROVIDE
 DEPTH OF PLANAR BREAKS (MINIMUM OF 3FT.).
  
 A - PLANAR BREAK DIMENSIONS ADDED.
  
 Z 01.27.23 - PARTIALLY SATISFIED. ON SHEET A1.5 PLANAR
 BREAKS FOR RAILROAD AVE AND N ROSEMARY ARE MET. PLEASE
 REVISE BUILDING FRONTAGE FOR 3RD STREET AS THE DRAWING
 SHOWS A DIFFERENT NUMBER FROM THE TABLE. IN ADDITION,
 PROVIDE PLANAR BREAKS FOR FACADES ON 4TH STREET.
  
 ON SHEET A1.5, PLEASE PROVIDE INFORMATION ABOUT 4TH
 STREET AND HOW MEETS ALL REQUIREMENTS SHOWN IN
 TABLES.MINIMUM ACTIVE USE CALCULATIONS NEED TO BE
 REVISED AS MENTIONED BEFORE.
  
 Z - PLEASE CLARIFY OR EXPLAIN THE FACADE PLANE
 CALCULATIONS: GROUND FLOOR TABLE, WHAT DOES THIS MEAN
 OR SHOW?
  
 A - TABLE HAS BEEN REMOVED. IT WAS INCLUDED IN ERROR.
  
 Z -TRANSPARENCY REQUIREMENTS MET.
  
 Z 01.27.23 - NEW COMMENT: ON SHEET A1.6 FRONTAGE
 DIAGRAMS, PLEASE CLEAN UP ELEVATIONS, THERE ARE LINES
 BELOW GROUND LEVEL. IN ADDITION, PLEASE ADD ACTIVE USE
 AND NON-ACTIVE USE DIMENSIONS AS SHOWN IN SEC. 94-109,
 TABLE IV-33. IT SEEMS THAT CALCULATIONS ARE NOT
 CORRECT, PLEASE REVISE. PLEASE ALSO ADD MINIMUM ACTIVE
 USE LINER DEPTH REQUIRED AND PROPOSED, SEE SEC. 94-128,
 TABLE IV-35A.
  
 Z 01.27.23 - NEW COMMENT: AS MENTIONED ON PREVIOUS
 COMMENT, PLEASE PROVIDE MORE INFORMATION ON ELEVATIONS
 DRAWINGS ABOUT FACADE MATERIALS AND ARCHITECTURAL
 TREATMENT DETAILS TO MEET FACADE ARTICULATION
 REQUIREMENTS ON SEC. 94-109, TABLE IV-4.
  
  
 COMMENT 12:
 Z - THE WALLS ON THE INTERIOR OF THE PUBLIC OPEN SPACE
 COURTYARD (BETWEEN 4TH AND 3RD) ARE BLANK, PLEASE
 PROVIDE SOME FENESTRATION, ARCHITECTURAL TREATMENT OR
 FACADE ARTICULATION ON THESE WALLS. - NORTHERN FA??ADE
 OF THE BUILDING (FACING SALVATION ARMY) APPEARS TO HAVE
 A LARGE BLANK WALL (>20%) PLEASE PROVIDE ADDITIONAL
 FENESTRATION, ARCHITECTURAL TREATMENT OR FA??ADE
 ARTICULATION TO THIS FRONTAGE. - WEST RAILROAD AVENUE,
 GROUND LEVEL FACADE WOULD BENEFIT FROM ADDITIONAL
 ARTICULATION.
  
 A - SEE SHEETS A3.1 AND A3.2 FOR REVISED ELEVATIONS.
  
 Z 11.17.22 - PARTIALLY SATISFIED
 INTERIOR WALLS OF THE PUBLIC OPEN SPACE COURTYARD
 APPEAR TO BE BLANK STILL WITHIN THE RENDERS PROVIDED.
 PLEASE PROVIDE CLARIFICATION ON IF THERE ARE ANY
 ARCHITECTURAL FEATURES, FENESTRATION, OR TREATMENTS ON
 THESE INSIDE WALLS. A2.1, A2.2, AND A2.3 SHOW
 DIFFERENCES IN FENESTRATION. ALSO A3.3 SHOWS WINDOWS
 AND FACADE ARTICULATION.
  
 A - PUBLIC OPEN SPACE #4 HAS FENESTRATION, EYEBROWS AND
 ACCENT COLORS AS SHOWN IN WEST ELEVATION (SHEET A3.1)
 AND COVER PERSPECTIVE VIEW (SHEET A0.0). THE BACK
 (WEST-FACING) WALL OF THE PUBLIC SPACE WILL HAVE A
 SERIES OF WINDOWS ON ALL LEVELS. THE INTERIOR WALLS
 WILL ALSO HAVE WINDOWS.
  
  
 Z 01.27.23 - PARTIALLY SATISFIED. FENESTRATION ON THE
 OPEN SPACE #4 IS MET ON THE WALL FACING WEST, NOTE ON
 THE WALLS FACING NORTH AND SOUTH, THE COVER SHEET A0.0
 SHOW WINDOWS ON THE GROUND FLOOR WHICH ARE NOT
 CONSISTENT WITH THE GROUND FLOOR PLANS A1.0, A1.4,
 A2.1. PLEASE ALSO CLARIFY IF THERE ARE EYEBROWS ON
 THESE WALLS.
  
  
 COMMENT 13:
 Z- BICYCLE PARKING REQUIRES 1 SPACE PER EVERY 100 FT.
 OF FRONTAGE, PUBLICLY ACCESSIBLE ALONG ROW/CURB (~5-6
 SPACES ON ROSEMARY; ~2 SPACES ON 3RD; ~3 SPACES ON W
 RAILROAD.)
  
 A - SEE SHEET A1.0 FOR REVISED SITE PLAN SHOWING
 BICYCLE PARKING SPACES.
  
 Z 11.17.22 - PARTIALLY SATISFIED
 PLEASE PROVIDE DETAIL OF BIKE RACKS TO BE PLACED WITHIN
 ROW TO ENSURE IT MEETS CITY STANDARDS.
  
 A - A REFERENCE DETAIL IMAGE HAS BEEN ADDED TO SHEET
 A0.2 TO CONVEY THE DESIGN INTENT OF THE PUBLICLY
 ACCESSIBLE BIKE RACKS.
  
 Z 01.27.23 - NOT SATISFIED, PLEASE CONTACT CLAUDIA
 IBAVEN VIA EMAIL TO PROVIDE YOU WITH THE CITY'S BICYCLE
 PARKING GUIDELINES. ONCE YOU REVIEWED THE GUIDELINES,
 MAKE SURE THAT YOU PROVIDE DETAILS ON THE ARRANGEMENT
 OF BIKE RACKS WITH DIMENSIONS AS NOTED IN THE
 GUIDELINES. AND PLEASE REVIEW SEC. 94-485 FOR OTHER
 BICYCLE PARKING REQUIREMENTS AND STANDARDS.
  
  
 COMMENT 14:
 Z - PLEASE INDICATE LOCATION OF BIKE ROOM, PROVIDE
 DETAILS OF HOW ROOM IS ACCESSED, AND PROVIDE THE TYPE
 OF RACKS OR DETAIL HOW THE BIKES ARE SECURED WITHIN THE
 ROOM.
  
 A - SEE SHEET A1.0 DESIGNED BICYCLE ROOMS IN EACH
 GARAGE. THE BICYCLE RACK DETAIL WILL BE PROVIDED IN THE
 PERMIT SET OF PLANS.
  
 Z 11.17.22 - PARTIALLY SATISFIED.
 PLEASE PROVIDE DIMENSION OF BIKE ROOM TO VERY SPACE IS
 ADEQUATE FOR TYPE OF RACKS/SECURING METHODS PROPOSED.
 PLEASE PROVIDE A DETAIL OF BIKE RACKS TO ENSURE IT
 MEETS CITY STANDARDS.
  
 A - SEE SHEET A2.1. BIKE STORAGE ROOMS HAVE BEEN
 DIMENSIONED AND BIKE STORAGE GRAPHICS HAVE BEEN ADDED.
 TOTAL BIKE STORAGE COUNT HAS BEEN UPDATED ON ZONING
 DATA SHEET A0.2.
  
 Z 01.27.23 PARTIALLY SATISFIED. PLEASE CLARIFY IF YOU
 WILL BE USING THE SAME BIKE RACK SPECS FOR BIKE RACKS
 LOCATED ADJACENT TO SIDEWALKS AND BIKE RACKS LOCATED
 INSIDE THE BIKE ROOMS. PLEASE CONTACT CLAUDIA IBAVEN
 VIA EMAIL TO PROVIDE YOU WITH THE CITY'S BICYCLE
 PARKING GUIDELINES. ONCE YOU REVIEWED THE GUIDELINES,
 MAKE SURE THAT YOU PROVIDE DETAILS ON THE ARRANGEMENT
 OF BIKE RACKS WITH DIMENSIONS AS NOTED IN THE
 GUIDELINES. AND PLEASE REVIEW SEC. 94-485 FOR OTHER
 BICYCLE PARKING REQUIREMENTS AND STANDARDS.
  
  
 COMMENT 15:
 Z - PLEASE PROVIDE PARKING STALL DETAILS, MAKE SURE THE
 STRIPING AND DIMENSIONS MEET CITY STANDARD. PLEASE
 PROVIDE DRIVE AISLE WIDTH, REQUIRED 24FT. MINIMUM.
 PLEASE PROVIDE PARKING RAMP SLOPES. PROVIDE DIMENSION
 OF LOADING AREA.
  
 A - SEE SHEET A1.0 FOR TYPICAL STALL AND AISLE
 DIMENSIONS, PARKING SLOPES AND LOADING AREA SIZES.
  
 Z 11.17.22 - NOT SATISFIED.
 PLEASE PROVIDE DIMENSIONS FOR ADA SPACES AND INCLUDE
 5FT ACCESS AISLE. PLEASE PROVIDE CONSISTENCY BETWEEN
 DRAWING SETS AND BE SURE THAT ALL ADA SPACES ARE
 ACCURATELY REPRESENTED BETWEEN SHEETS, SOME DRAWINGS
 HAVE THE SPACES MISSING.
 PLEASE CONSIDER ADDITIONAL ADA SPACES FOR GROUND FLOOR.
  
 A - SHEETS A2.1, A2.2, AND A2.3 HAVE BEEN REVISED TO
 SHOW ALL ADA SPACES AND ACCESS AISLES.
  
 Z 01.27.23 - PARTIALLY SATISFIED. ON SHEET A2.1, PLEASE
 PROVIDE DIMENSIONS ON THE AREA WHERE AN ADA SPACE IS IN
 PROXIMITY WITH THE ENTRANCE TO THE BUILDING AS IT SEEMS
 TO BE TOO SMALL.
 ON SHEET A2.2, NORTH BUILDING, THERE IS A COLUMN IN
 FRONT OF THE MAIN ENTRANCE WHICH MIGHT NOT BE ADA
 ACCESSIBLE, PLEASE REVISE.
  
 PLEASE REVIEW SEC. SEC. 94-485 AND PROVIDE A PARKING
 STANDARD DETAIL SHOWING DIMENSIONS, PAINTING DETAILS,
 ETC., AS WELL AS FOR ADA PARKING SPACES.
  
 PLEASE LABEL 'TANDEM PARKING' ON DRAWINGS. NOTE, AS PER
 SEC. 94-111 (E)(2), TANDEM PARKING, IF PROVIDED, MAY
 COUNT AS TWO SPACES, PROVIDED BOTH SPACES ARE DEDICATED
 TO THE SAME RESIDENTIAL UNIT, AND A RESTRICTIVE
 COVENANT IS RECORDED ON CITY APPROVED FORMS, AND
 RECORDED IN THE PUBLIC RECORDS. ALSO, ADD # OF TANDEM
 PARKING SPACES ON TABLE 6 - PARKING AND LOADING ON
 SHEET A0.2.
  
 Z - ON SHEET A1.0, WHAT IS THE PATH OF ENTRY/EXIT FOR
 AN ADA USER WITHIN THE SOUTHERN BUILDING? THERE IS NO
 CLEAR ACCESS INTO THE BUILDING OR DIRECT CONNECTION TO
 ELEVATORS, PLEASE ADJUST.
  
 A - SHEETS A2.1, A2.2, AND A2.3 HAVE BEEN REVISED TO
 SHOW HATCHED AREAS INDICATING ACCESSIBLE PATHS FROM
 PARKING SPACE TO BUILDING ENTRY.
  
 Z 01.27.23 - PARTIALLY SATISFIED - SOME DOORS TO UNITS
 SEEM TO BE MISSING IN PLANS. PLEASE CLARIFY IF INSIDE
 THE PARKING LOT, PEOPLE CAN ONLY ACCESS THE BUILDING
 UNITS THROUGH THE 'BUILDING ACCESS'.
  
 Z - ARE ALL INTERNAL PARKING RAMPS 12% SLOPE?
  
 A - SEE SHEETS A2.1, A2.2, AND A2.3 FOR REVISED PARKING
 RAMP SLOPES. TYPICAL SLOPES ARE 16% WITH 8% BLENDS AT
 TOP AND BOTTOM.
  
 Z 01.27.23 - SATISFIED
  
 Z - ADA SPACE ON SHEET A2.3 DOES NOT PROVIDE ACCESS
 AISLE OR CLEAR PATH TO ELEVATOR. CAN THIS BE RELOCATED?
  
 A - SHEETS A2.1, A2.2, AND A2.3 HAVE BEEN REVISED TO
 SHOW HATCHED AREAS INDICATING ACCESSIBLE PATHS FROM
 PARKING SPACE TO BUILDING ENTRY.
  
 Z 01.27.23 - SAME COMMENT AS ABOVE, PARTIALLY
 SATISFIED. ON SHEET A2.1, PLEASE PROVIDE DIMENSIONS ON
 THE AREA WHERE THE ENTRANCE IS ADJACENT TO THE ADA AS
 IT SEEMS TO BE TOO SMALL. ON SHEET A2.2, NORTH
 BUILDING, THERE IS A COLUMN IN FRONT OF THE MAIN
 ENTRANCE WHICH SEEMS TO BE NOT ADA ACCESSIBLE.
  
 Z 01.27.23 - NEW COMMENT: PLEASE CLARIFY IF PARKING LOT
 RAMPS ON THE SOUTH BUILDING CHANGE LOCATION. ON THE
 GROUND FLOOR AND 2ND FLOOR ARE LOCATED ON THE SAME
 AREA, ON 3RD AND 4TH FLOOR RAMP ON THE SOUTH CHANGED
 LOCATIONS.
  
  
 COMMENT 16: RENDERS
  
 Z 11.17.22 SATISFIED
  
  
  
 COMMENT 17: RETAIL SPACE
 Z 11.17.22 - SATISFIED
 CAN A RETAIL SPACE BE ACCOMMODATED ON THE GROUND FLOOR
 OF 4TH ST. FRONTAGE WHERE CURRENTLY THERE ARE LARGE
 LOBBIES AND AMENITY ROOMS? BRINGS MORE ACTIVITY TO THE
 BUILDING AND PUBLIC OPEN SPACES.
  
 Z 01.27.23 NEW COMMENT. AS PREVIOUSLY MENTIONED, A
 STUDY HAS BEEN PRODUCED, BY THE CITY AND CRA, TO
 REDEVELOP N ROSEMARY AVE WITH THE GOAL OF ACTIVATING
 THE STREETSCAPE. GROUND LEVEL COMMERCIAL USE IS
 RECOMMENDED, AND NEW DEVELOPMENT IS ALREADY
 INCORPORATING RETAIL USE ON GROUND FLOORS CHANGING THE
 CURRENT STREETSCAPE CONDITIONS ON N ROSEMARY AVE,
 ENCOURAGING MORE ACTIVITY IN THE DOWNTOWN AREA.
 BUILDING CORNERS ON N ROSEMARY AVE AND 3RD STREET AND
 4TH STREET CAN INCORPORATE NEW RETAIL AMENITIES TO
 RESIDENTS, ATTRACT THE PUBLIC IN GENERAL, AND ALIGN
 WITH THE GOALS OF THE DOWNTOWN MASTER PLAN. PLEASE
 EXPLORE INCORPORATING RETAIL IN THESE AREAS OR AT LEAST
 IN THE CORNER OF N ROSEMARY AND 3RD STREET.
  
  
 COMMENT 18:
 Z - RECOMMEND EXPLORING ADDITIONAL ARCHITECTURAL
 TREATMENTS, FACADE ARTICULATION, OR DESIGNS TO THE
 CORNER/INTERSECTION OF 3RD AND N ROSEMARY. THIS IS A
 FOCAL POINT AND SERVES AS A GATEWAY INTO THE NORTHWEST
 NEIGHBORHOOD, GREAT OPPORTUNITY TO MAKE A STANDOUT OR
 SPECIAL FRONTAGE.
  
 A - SEE SHEETS A3.1 AND A3.2 FOR REVISED ELEVATIONS.
 CORNER OF 3RD AND ROSEMARY SHOWS A MORE ARTICULATED
 FA??ADE WITH RECESSED, DOUBLE-HEIGHT LIVE-WORK UNIT AND
 WRAP-AROUND BALCONY.
  
 Z 11.17.22 - NOT SATISFIED
 LANDSCAPE REMOVED FOR ADDITIONAL HARDSCAPE. PLEASE
 INCLUDE PEDESTRIAN CROSSINGS OVER ROSEMARY AND 3RD
 STREET. PLEASE CONSIDER OPENING THIS CORNER UP MORE.
  
 A - CORNER PLAZA HAS BEEN OPENED UP MORE TO ALLOW FOR
 MORE LANDSCAPING. REFER TO CIVIL SHEET C-8.
  
 Z 01.27.23 - NOT SATISFIED. PLEASE CLARIFY CHANGES MADE
 ON SHEET C-8 COMPARED TO PREVIOUS SUBMITTAL.
  
 Z 01.27.23 - NEW COMMENT, PLEASE MAKE SURE THAT
 LANDSCAPE AND ARCHITECTURAL PLANS ARE CONSISTENT WITH
 CHANGES ON SHEET C-8. ON SHEET C-8, THE 3RD STREET
 CORNER, PLEASE CLARIFY IF THE EXISTING CROSSWALK WILL
 BE REMOVED OR IF THE PROJECT WILL ADD SIDEWALK TO MEET
 THE EXISTING CROSSWALK AS IT IS NOT SHOWING ON OTHER
 ARCHITECTURAL AND LANDSCAPE PLANS. PLEASE SHOW ALL
 EXISTING OR PROPOSED CROSSINGS ON A1.0 AND ADD
 CROSSINGS ON 4TH STREET.
  
 Z - RELOCATE MICROMOBILITY SPACE TO THE AREA UNDER THE
 BRIDGE IN FRONT OF AMENITY SPACE ON 4TH STREET.
 PROVIDES COVER AND FREES UP ADDITIONAL SPACE FOR
 LANDSCAPE, ETC.
  
 A - SEE SHEET A1.0. MICRO MOBILITY SPACE HAS BEEN
 RELOCATED TO THE SUGGESTED LOCATION.
  
 Z 01.27.23 - SATISFIED.
  
 Z- WILL THE LIVE-WORK UNIT PROVIDE ACCESS FROM 3RD
 STREET NOW INSTEAD OF THE PREVIOUS ROSEMARY ENTRY?
  
 A - STREET ACCESS TO LIVE/WORK UNIT WILL BE FROM
 ROSEMARY.
  
 Z 01.27.23 - PARTIALLY SATISFIED, PLEASE CLARIFY IF
 FOLKS PARKING INSIDE THE LOT WILL HAVE TO GO OUT OF THE
 BUILDING TO ACCESS THE UNIT. IN ADDITION, SEE COMMENT
 NO. 17.
  
  
 COMMENT 19:
 Z 11.17.22 - SATISFIED
  
  
 COMMENT 20:
 Z 11.17.22 - SATISFIED
  
  
 COMMENT 21:
 Z- SHEET A4.1 & A4.2, PLEASE EXPLAIN OR CLARIFY HOW THE
 BRIDGE AND PARKING LEVELS RELATE TO THE OVERALL FLOOR
 PLATES OF THE BUILDING, DOES NOT APPEAR TO BE
 LEVEL/LOOKS TO BE A HALF OR QUARTER-FLOOR DIFFERENCE IN
 THE ALIGNMENT. HOW DOES THIS SPACE FUNCTION IN RELATION
 TO THE OVERALL BUILDING? INTERNALLY RAMPS UP?
  
  
 A - PARKING IS ORGANIZED IN A SPLIT-LEVEL ARRANGEMENT.
 ONE PART OF THE GARAGE ALIGNED TO THE MAIN HABITABLE
 LEVEL; THE OTHER PART IS MIDWAY BETWEEN MAIN HABITABLE
 LEVELS. THE BRIDGE LEVELS HAVE BEEN REWORKED TO ALIGN
 WITH THE MAIN HABITABLE LEVELS.
  
 Z 11.17.22 - NOT SATISFIED
 SECTION DRAWINGS NEED TO BE CLEANED UP OR CLARIFIED
 FURTHER. THERE ARE MANY INSTANCES DOUBLE SLAB LINES,
 WHERE THE SLAB UNDULATES OR VARIES BETWEEN LEVELS, AND
 IT IS NOT CLEAR HOW THE SPACES RELATE TO THE FLOOR
 PLANS.
  
 SECTION A ON SHEET A4.1: THE BRIDGE BETWEEN THE TWO
 BUILDINGS SHOWS A WHITE BOX/ROOM LABELED PARKING, BUT
 THIS SPACE DOES NOT EXIST ON THE 3RD FLOOR PLAN, THIS
 IS AN AMENITY SPACE. THE RELATIONSHIP BETWEEN THE TWO
 PARKING LEVELS BETWEEN THE BRIDGE IS NOT CLEAR.
  
 A - SECTION SHEET A4.1 HAS BEEN CLEANED UP TO SHOW
 PARKING WITHIN THE BRIDGE ON LEVELS 3 AND 4.
  
  
 Z - SECTION A ON SHEET A4.1: DOES THE LOADING BAY RAMP
 UP INTO THE GARAGE? THE CHANGE IN SLABS IS CONFUSING.
 IT??? S UNDERSTOOD THAT THE NORTHERN PORTION OF THE
 PARKING STRUCTURE HAS A HALF LEVEL STEP DOWNWARD, BUT
 IS THE REST OF THE PARKING AND LOADING ON A SLAB ABOVE
 GRADE? WHY ARE THERE TWO DIFFERENT FLOOR SLABS?
  
 A- SECTION ON SHEET A4.1 HAS BEEN CLEANED UP TO REMOVE
 THE DOUBLE SLABS. THE LOADING BAYS ARE SLIGHTLY LOWER
 THAN THE ADJACENT PARKING DECKS. STAIRS/RAMPS HAVE BEEN
 ADDED TO NEGOTIATE THIS LEVEL CHANGE. SEE GROUND FLOOR
 PLAN (SHEET A2.1)
  
 Z- SECTION A ON SHEET A4.1: PLEASE CLEAN UP OR CLARIFY
 WHAT IS HAPPENING ON THE 4TH STREET PORTION OF THE
 SECTION, TWO SEPARATE LINES INDICATING THE FLOOR OF THE
 BUILDING AND ROADWAY.
  
 A- SECTION ON SHEET A4.1 HAS BEEN CLEANED UP TO REMOVE
 THE DOUBLE SLABS.
  
 Z - SECTION A ON SHEET A4.1: PLEASE CLARIFY DOES THE
 SOUTHERN BUILDING STEP DOWN IN THE PARKING GARAGE? TWO
 DIFFERENT FLOOR SLABS AND ELEVATIONS SHOW BETWEEN
 PARKING LEVEL AND REST OF BUILDING/SIDEWALK.
  
 A - THE LOADING BAYS ARE SLIGHTLY LOWER THAN THE
 ADJACENT PARKING DECKS. STAIRS/RAMPS HAVE BEEN ADDED TO
 NEGOTIATE THIS LEVEL CHANGE.
  
 Z - SECTION B ON SHEET A4.1: CLARIFY THE TWO BOLDED
 LINES FOR THE FLOOR ELEVATION/SLAB AND SIDEWALK/AT
 GRADE LEVEL.
  
 A - SECTION ON SHEET A4.1 HAS BEEN CLEANED UP TO REMOVE
 THE DOUBLE SLABS.
  
 Z 01.27.23 - NOT SATISFIED: PLEASE ADD PROPERTY LINES
 SETBACK LINES, AND DIMENSIONS TO PARAPET TO SECTIONS
 JUST AS DONE ON ELEVATIONS DRAWINGS TO SHOW HIGHEST
 POINT OF THE BUILDING.
 ON SHEET A4.1, SECTION 1 - A IS NOT MATCHING GROUND
 FLOOR PLAN, PLEASE REVISE. SECTION 2 - B IS CUTTING ON
 THE STREET BUT NOT SHOWING ANY STEPS OR RAMP FOR
 PEDESTRIANS ENTERING THE SOUTH LOBBY AMENITY SPACE.
  
  
 Z - SECTION C AND D ON SHEET A4.2: PLEASE CLARIFY THE
 GROUND LEVEL CONDITIONS, TWO SEPARATE BOLD LINES SHOWN
 AGAIN, WHAT IS THE FINISHED FLOOR ELEVATION AND ARE
 THERE ADDITIONAL STEPS DOWN/UP FOR THE GROUND LEVEL?
 PLEASE PROVIDE FINISHED FLOOR ELEVATIONS, OR LEADERS ON
 THE DRAWINGS AND INDICATE AREAS WITH ANY STEPS OR
 RAMPS.
  
 A - SECTION ON SHEET A4.1 HAS BEEN CLEANED UP TO REMOVE
 THE DOUBLE SLABS. SPOT ELEVATIONS HAVE BEEN ADDED TO
 SHEET A2.1, AS WELL AS STAIRS/RAMPS TO NEGOTIATE
 CHANGES IN LEVEL. SEE GROUND FLOOR PLAN (SHEET A2.1)
  
 Z 01.27.23 - NOT SATISFIED: PLEASE ADD PROPERTY LINES,
 SETBACK LINES, AND DIMENSIONS TO PARAPET TO SECTIONS
 JUST AS DONE ON ELEVATIONS DRAWINGS TO SHOW HIGHEST
 POINT OF THE BUILDING.
 ON SHEET A2.1 ON PARKING LOT THERE IS A RAMP WITH A 5%
 SLOPE AND ON SHEET A4.2, SECTION 2-C, THIS IS NOT
 REFLECTED IT. THE RAMP SEEMS TO GO DOWN TOWARDS
 RAILROAD AVE TO MEET THE STREET LEVEL AND THE SECTION
 DOES NOT MEET THE STREEL LEVEL. IN ADDITION, ACCORDING
 TO THE SHEET A2.2 AND A2.3 THE PARKING LOT FLOOR LEVELS
 ARE THE SAME AS THE UNIT'S FLOOR LEVELS AND THE SECTION
 DOES NOT REFLECT THAT. SECTION 3-D, A SMALL RAMP ON THE
 GROUND FLOOR DOES NOT MATCH THE FLOORPLAN. PLEASE
 REVISE DRAWINGS.
  
  
  
 COMMENT 22:
 Z - UPDATED RENDERS PROVIDED ON 9.8.22 SHOW THE
 GROUND-LEVEL WALKUP UNITS ENCLOSED BY A RAILING OR
 FENCE, WHAT IS THE TOTAL HEIGHT OF THE WALL + RAILING?
  
 A - THE HEIGHTS OF THE WALLS WILL VARY DEPENDING ON THE
 SIDEWALK???S RELATIONSHIP TO THE ADJACENT WALK-UP
 GARDEN FINISH FLOOR ELEVATION (A DIFFERENCE OF APPROX.
 2??? ??? 3.5???). THE RAILING WILL BE 42??? ABOVE THE
 TOP OF THE WALL.
  
 Z 11.17.22 - NOT SATISFIED
 PER SECTION 94-109 WALK-UP GARDEN: FENCES, WALLS OR
 OTHER SIMILAR STRUCTURES SHALL NOT EXCEED FOUR FEET IN
 HEIGHT. PLEASE REFER TO FIGURE IV-34.
  
 PLEASE PROVIDE A DETAIL OF THE WALK-UP UNITS SPECIFYING
 THE DIMENSIONS OF THE DIFFERENT ELEVATION CHANGES,
 FLOOR LEVELS, WALLS/FENCE, AND PROJECTIONS AS IS
 APPLICABLE. BE SURE RENDERS ARE ACCURATE TO PLANS.
  
 A - WALK UP GARDEN GATE, WALLS, AND STEPS HAVE BEEN
 REVISED. SEE DETAIL SECTION AND PLAN ON SHEET A1.4
  
 Z 01.27.23 - SATISFIED.
  
  
 COMMENT 23:
 Z 11.17.22 - SATISFIED
 RENDERS PROVIDED DO NOT ACCURATELY REFLECT CHANGES TO
 SITE PLAN OR ELEVATIONS OR THE RENDER IN SHEET A5.1.
 PLEASE ADDRESS PRIOR TO DAC.
  
 A- RENDERINGS WILL BE UPDATED PRIOR TO DAC
  
 Z 01.27.23 - NOT SATISFIED, RENDERS WILL NEED TO BE
 PROVIDED AS PART OF THE RESUBMITTAL.
  
  
  
 COMMENTS 11/18/22:
  
 COMMENT 1:
 Z - PLEASE ILLUSTRATE ALL ENTRY/EXIT AND DOORS ON THE
 GROUND LEVEL AND UPPER FLOOR PLANS TO CLARIFY USER
 CIRCULATION AND ACCESS THROUGHOUT THE BUILDING.
  
 A - BUILDING ACCESS DOORS HAVE BEEN LABELED ON GROUND
 LEVEL, GARAGE LEVELS AND AMENITY LEVEL PLANS.
  
 Z 01.27.23 - PARTIALLY SATISFIED. AS MENTIONED ABOVE,
 SOME FLOOR PLANS ARE MISSING DOORS TO UNITS, AND ON
 SHEET A2.2 THERE IS A COLUMN IN FRONT OF ACCESS TO THE
 BUILDING FROM THE NORTH BUILDING PARKING LOT.
  
 COMMENT 2:
 Z - MAX FOOTPRINT LENGTH PERMITTED FOR NWD-8
 SUBDISTRICT IS 250???, PROPOSED SOUTH BUILDING EXCEEDS
 MAX LENGTH AT 265???. PLEASE ADDRESS/ADJUST.
  
 A - PER CONVERSATIONS WITH STAFF, IT WAS UNDERSTOOD
 THAT THE FA??ADE LENGTH COULD EXCEED 250??? BY
 PROVIDING A PUBLIC OPEN SPACE TO BREAK UP THE BUILDING
 LENGTH.
  
 Z 01.27.23 - NOT SATISFIED. PER SEC. 94-128, TABLE
 IV-35A, THERE IS A MAXIMUM 250FT FOOTPRINT LENGTH ALONG
 ROSEMARY AVE, THIS AFFECTS THE FOOTPRINT LENGTH ON THE
 SOUTH BUILDING, PLEASE REVISE AS THIS IS NOT A VARIANCE
 THAT CAN BE GRANTED. IN ADDITION, THERE IS THE 150FT
 MAXIMUM CONTINUOUS BUILDING FRONTAGE ON ROSEMARY AVE
 THAT CAN BE BROKEN BY ADDING PUBLIC OPEN SPACE, THIS
 REQUIREMENT AFFECTS THE NORTH BUILDING, PLEASE REVISE.
 FOR 'BUILDING FRONTAGE' PLEASE SEE SEC. 94-109, FIGURE
 IV-7. FOR 'FOOTPRINT LENGTH' SEE SEC. 94-109, FIGURE
 IV-12.
  
  
 COMMENT 3:
 Z - SHEET A0.2 TABLE 5 NEEDS TO BE ADJUSTED. SHOULD
 REFLECT SHEET A1.5 CALCULATIONS AND DESCRIPTION/LABEL.
  
 A - SHEET A0.2, TABLE 5 HAS BEEN ADJUSTED TO REFERENCE
 CALCULATIONS ON SHEET A1.5.
  
 Z 01.27.23 - NOT SATISFIED, REVISE MINIMUM ACTIVE USE
 TABLE, AND SEE ABOVE COMMENTS RELATED TO CALCULATIONS
 ON SHEET.
  
  
 COMMENT 4:
 Z - PLEASE MOVE THE TREES TO BE ADJACENT TO THE CURB
 ALONG THE 4TH ST. EXTENSION, THESE SHALL SERVE AS THE
 REQUIRED STREET TREES (MAX. 30 FT ON CENTER). PLEASE
 ALSO INCLUDE TREES ON BOTH SIDES OF 4TH ST, CONTINUOUS
 SHADE FOR PEDESTRIANS.
  
 A - PLEASE, SEE REVISED LANDSCAPE SHEETS.
  
 Z 01.27.23 - PARTIALLY SATISFIED. SOME TREES ARE SPACED
 OUT MORE THAN 30FT. PLEASE ADJUST. IN ADDITION, SOME
 TREES SEEM TO BE NOT IN THE MIDDLE OF LANDSCAPE AREA
 AND ALMOST IN THE SIDEWALK.
 PLEASE NOTE ON 4TH STREET SOUTH SIDEWALK GREEN AREAS
 WHERE TREES ARE LOCATED ON THE WEST SIDE OF THE BLOCK
 ARE NOT SHOWING ON A1.0 JUST LIKE IT SHOWS ON L-1.
 NOTE, MORE COMMENTS ABOVE FOR STREETSCAPE AND LANDSCAPE
 REQUIREMENTS.
  
  
 COMMENT 5:
 Z - THE TWO ADJACENT PUBLIC OPEN SPACES ALONG 4TH
 STREET STILL LOOK AND READ AS ONE LINEAR SPACE. ISSUE
 IS THAT NO PUBLIC SPACE CAN HAVE 1 SIDE 5X THE LENGTH
 OF THE OTHERS. THE PUBLIC OPEN SPACE ALSO SEEMS TO
 SERVE THE GROUND LEVEL UNITS MORE THAN GENERAL PUBLIC,
 MOVING THE TREES TO THE CURB MAY HELP OPEN THE SPACE
 UP. STAFF ALSO SUGGESTS THAT THE UNITS THAT ARE FACING
 THE INTERSECTION OF W. RAILROAD AVE AND 4TH ST SHIFT
 SLIGHTLY OR CHANGE IN DIMENSION. CREATE MORE OF AN OPEN
 COURTYARD SPACE RATHER THAN A LINEAR ONE. ADDITIONALLY
 A PORTION OF THE OPEN SPACE CAN BE UNDER THE OVERHEAD
 BRIDGE (MAX. 20% OVERHEAD COVERAGE) TO PROVIDE
 ADDITIONAL SEPARATION BETWEEN TWO PUBLIC OPEN SPACES.
  
 A - PUBLIC SPACES #1 AND #2 HAVE BEEN SEPARATED AS
 SUGGESTED. TREES HAVE ALSO BEEN SHIFTED TO CURB AS
 SUGGESTED.
  
 Z 01.27.23 - OTHER COMMENTS HAVE BEEN MADE ON OPEN
 SPACE DIAGRAMS, LANDSCAPING AND STREETSCAPE ABOVE.
  
  
 COMMENT 6:
 Z - PLEASE PROVIDE PEDESTRIAN CROSSINGS AND ADA RAMPS
 ALONG THE INGRESS/EGRESS OF 4TH ST. EXTENSION. AS WELL
 AS AT THE CORNER OF 3RD AND ROSEMARY.
  
 A - PLEASE, REFER TO CIVIL SHEET C-5.
  
 Z 01.27.23 - NOT SATISFIED, AS MENTIONED BEFORE PLEASE
 ADD CROSSINGS TO THE SITE PLAN AND LANDSCAPE PLANS TO
 SHOW CONSISTENCY IN DESIGN. ALSO PROVIDE PEDESTRIAN
 CROSSINGS ON 4TH STREET.
  
  
 COMMENT 7:
 Z - PLEASE PROVIDE A PHOTOMETRIC PLAN FOR THE PROJECT
 SITE, REQUIREMENT IS A MINIMUM OF 0.6 FOOTCANDLES AS
 MEASURED AT THE BACK EDGE OF THE CURB AND ONE FOOT
 ABOVE THE SIDEWALK. ADDITIONALLY PLEASE PROVIDE A
 DETAIL AND SPECS OF THE PROPOSED LIGHT FIXTURES. CITY
 STANDARD FOR DECORATIVE STREET LAMPS IS THE LUMEC
 S55-007)
  
 A- UNDERSTOOD. PLEASE, SEE PROVIDED PHOTOMETRIC.
  
 Z - 01.27.23 - SATISFIED.
  
  
 OTHER COMMENTS:
  
 PLEASE NOTE, AS PER SEC. 94-54 (A)(1), THE APPLICANT
 SHALL ADDRESS ANY COMMENTS OF THE PPRC AND SUBMIT A
 REVISED APPLICATION WITHIN 60 DAYS OF THE DATE OF SUCH
 COMMENTS. FAILURE TO MAKE THE REQUIRED SUBMITTALS
 WITHIN THE 60-DAY DEADLINE WILL DEEM THE APPLICATION AS
 WITHDRAWN. AT LEAST 15 DAYS PRIOR TO THE EXPIRATION OF
 THE 60-DAY REVISION PERIOD, THE APPLICANT MAY REQUEST A
 30-DAY EXTENSION. NO FURTHER EXTENSION REQUEST IS
 PERMITTED. COMMENTS RELATING TO REVISED APPLICATIONS
 SHALL BE ADDRESSED WITHIN 30 DAYS OF THE DATE OF SUCH
 COMMENTS.
  
 WHEN RESUBMITTING, WRITTEN RESPONSES TO COMMENTS NEED
 TO BE PROVIDED AS WELL AS A MINIMUM OF TWO (2) PAPER
 COPIES AND AN ELECTRONIC COPY IN .PNG/.PDF FORMAT OF
 ALL PLANS AND ALL DOCUMENTATION REQUIRED IN THE
 APPLICATION. PLEASE NOTE THAT CHANGES ON THE
 RESUBMITTED PLANS OR THE SUBMITTAL OF INFORMATION/PLANS
 TO ADDRESS THE COMMENTS MAY RESULT IN ADDITIONAL
 COMMENTS.
  
 LASTLY, YOU WERE PERMITTED ONE (1) RESUBMITTAL AT NO
 ADDITIONAL COST. AS PREVIOUSLY ISSUED COMMENTS CONTINUE
 TO NOT BE SUFFICIENTLY ADDRESSED, THE APPLICANT WILL BE
 ASSESSED A RESUBMITTAL FEE. SUCH FEE WILL BE 20% OF THE
 ORIGINAL APPLICATION FEE.
  
 --END OF COMMENTS---
  

Review Stop Z ZONING
Rev No 2 Status F Date 11-22-2022 Cont ID  
Sent By ckimmerl Date 11-22-2022 Time 11:02 Rev Time 0.00
Received By ckimmerl Date 11-22-2022 Time 11:01 Sent To  
Notes
2022-11-22 11:02:43ZONING:
  
 1. ACTIVE USE: PLEASE NOTE THAT ACTIVE USES ARE
 REGULATED AS A PERCENTAGE OF THE BUILDABLE LOT
 FRONTAGE, NOT THE BUILDING FRONTAGE. PLEASE ADJUST
 CALCULATIONS ACCORDINGLY.THE PERCENTAGE SHOULD BE 80%
  OF THE ENTIRE N ROSEMARY AVE. PROPERTY LINE (60% FOR
  LINERS 2-5), 30% OF THE 3RD ST. PROPERTY LINE, AND
 THEN 30% OF THE W. RAILROAD AVE. PROPERTY LINE.
  
  RESPONSE: SEE SHEET A1.5 FOR ACTIVE USE DIAGRAMS AND
 CALCULATIONS.
  
 ZONING 11.17.22 ??? PARTIALLY SATISFIED
 TABLE ON SHEET A0.2 DIFFERS FROM CALCULATIONS ON A1.5
 ??? A1.5 IS LABELED CORRECTLY PLEASE ADJUST.
  
 2. PLEASE PROVIDE OWNERS CONSENT OR PROOF OF AGREEMENT
 BETWEEN THE NEIGHBORING PROPERTY OWNER OF 411 W
 RAILROAD AVE. TO ALLOW FOR THE EXTENSION OF 4TH ST.
 OVER THEIR PROPERTY.
  
 RESPONSE: THE RECORDED EASEMENT PROVIDING AUTHORITY TO
 MAKE THESE IMPROVEMENTS ARE INCLUDED WITHIN THIS
 SUBMITTAL. NO ADDITIONAL CONSENT IS REQUIRED FROM THE
 ADJACENT PROPERTY OWNERS AS THE EASEMENT ALLOWS EITHER
 PARTY THE AUTHORITY TO MAKE THE CONTEMPLATED
 IMPROVEMENTS DENOTED WITHIN THE EASEMENT ITSELF.
  
 ZONING 11.17.22 ??? PARTIALLY SATISFIED
 EASEMENT AGREEMENT PROVIDED ??? EASEMENT EXHIBIT B
 SHOWS A 50FT. EASEMENT, PLANS SHOW 60FT. WHY THE
 ADDITIONAL 10 FT.?
  
 3. RADIUS OF THE CURB-CUT OR APRON FOR THE NORTHERN
 SERVICE ACCESS ENCROACHES INTO CITY PROPERTY, PLEASE
 ADJUST.
  
  RESPONSE: SHEET A1.0 SHOWS REVISED CURB CUT.
  
 ZONING 11.17.22 ??? PARTIALLY SATISFIED
 ADJUSTMENT MADE, HOWEVER PORTION OF CURBCUT RADIUS
 STILL SHOWN AS PART OF ADJACENT PROPERTY ON NORTHERN
 SERVICE ROAD (WEST RAILROAD AVE) AND EASTERN SERVICE
 ROAD (3RD ST).
  
  
 4. THE SERVICE ACCESS ALONG THE SOUTHERN AND NORTHERN
 SIDE OF THE PROPERTY DOES NOT PROVIDE REQUIRED 5 FT.
 LANDSCAPE BUFFER ALONG THE PROPERTY LINE AND TO SCREEN
 THE VEHICULAR USES. SERVICE ROADS WILL HAVE TO BE
 ADJUSTED TO ACCOMMODATE FOR THE BUFFER.
  
  RESPONSE: SHEET A1.0 SHOWS REVISED SERVICE ACCESS AND
 BUFFER.
  
 ZONING 11.17.22 ??? PARTIALLY SATISFIED
 NORTHERN SERVICE ROAD (ADJACENT TO CITY PROPERTY)
 INCLUDES LIVE OAK, GREEN BUTTONWOOD, AND COCOPLUM
 GROUND COVER WHICH SATISFIES THE LANDSCAPE BUFFER.
 SUGGEST PLANTING HEDGES TO FURTHER SCREEN LOADING
 BAY/OPERATION FROM ROSEMARY AND ADJACENT PROPERTY.
  
 SOUTHERN SERVICE ROAD (3RD ST.) INDICATES SYNTHETIC
 TURF, THIS DOES NOT SATISFY LANDSCAPE BUFFER
 REQUIREMENTS NOR IS IT PERMITTED IF SEEN FROM THE ROW
 (4TH ST. EXT OR 3RD ST.) PLEASE ADJUST TO INCLUDE REAL
 PLANT MATERIAL AND/OR GROUND COVER.
  
 5. SHEET A0.2, SITE INFORMATION TABLES REQUIRE
 CORRECTIONS:
  
  - IF LOT AREA IS 108,638; THEN WITH A 2.75 FAR MAXIMUM
 ALLOWED IS 298,755 SF, NOT 298,729 SF.
  
  - REQUIRED PRIVATE OPEN SPACE AT 25% IS 27,160 SF, NOT
 27,158 SF.
  
  - CONDITIONAL 50? SETBACK IS FROM ABOVE THE 5TH FLOOR,
 NOT THE 6TH.
  
  - GBA SHOULD MATCH FAR CALCULATION.
  
  - PLEASE DOUBLE CHECK ALL CALCULATIONS AND DIMENSIONS
 FOR CONSISTENCY ACROSS PLANS.
  
  RESPONSE: SHEET A0.2 SHOWS REVISED DATA.
 ZONING 11.17.22 ??? PARTIALLY SATISFIED
 TABLE ON SHEET A0.2 DIFFERS FROM CALCULATIONS ON A1.5
 ??? A1.5 IS LABELED CORRECTLY PLEASE ADJUST.
  
  
 6. OPEN SPACE REQUIREMENT:
  
 A. PLEASE CLARIFY THE 4TH ST. EXTENSION. IS IT A
 PRIVATE ROAD WITH PUBLIC ACCESS AGREEMENT/EASEMENT?
 DOES IT SERVE AS A PUBLIC ROW?
  
  RESPONSE: 4TH STREET EXTENSION IS PROPOSED AS A
 PRIVATE ROAD WITH PUBLIC ACCESS EASEMENT.
 ZONING 11.17.22 ??? PARTIALLY SATISFIED (SEE NEW
 COMMENT #5)
  
 B. IF 4TH ST. IS AN EXTENSION OF THE PUBLIC ROW, THEN
 IT REQUIRES A SETBACK ON EITHER SIDE AND SHOULD BE
 DESIGNED WITH STREETSCAPE REQUIREMENTS IN MIND. IF IT
 IS NOT CONSIDERED A PUBLIC ROW, THEN PUBLIC OPEN SPACE
 #2 DOES NOT MEET REQUIREMENT OF A COURTYARD TO HAVE
 PUBLIC ROW ABUTMENT. PUBLIC OPEN SPACES SHOULD NOT BE
 LOCATED ALONG THE PRIVATE DRIVE AS THAT IS NOT THE
 INTENTION OF THE CODE, SPACES SHOULD BE PUBLICLY
 ACCESSIBLE AND VISIBLE; OTHERWISE, PEDESTRIANS WILL NOT
 UTILIZE THE SPACE AS DESIGNED.
  
 RESPONSE: AFTER DISCUSSIONS WITH STAFF, 4TH STREET IS
 PROPOSED AS A PRIVATE ROAD WITH PUBLIC ACCESS EASEMENT.
 IT IS DESIGNED WITH 8??? SIDEWALKS AND TREE GRATES. IT
 WAS UNDERSTOOD THAT PUBLIC OPEN SPACE WOULD BE ALLOWED
 TO ABUT THE 4TH STREET EXTENSION.
 ZONING 11.17.22 ??? PARTIALLY SATISFIED (SEE NEW
 COMMENT #5)
  
 C. ON SHEET A1.4 PUBLIC OPEN SPACE #1 AND #2 SHOULD BE
 COMBINED INTO A SINGLE SPACE, THE WALKWAY/SIDEWALK DOES
 NOT DELINEATE SEPARATE SPACES, AS IT IS SHOWN THE OPEN
 SPACE WOULD HAVE TO HAVE ITS PROPORTIONS CHANGED AS NO
 SINGLE SIDE CAN BE 5X THE LENGTH OF THE OTHER. THIS IS
 A VERY LINEAR OPEN SPACE.
  
  RESPONSE:
  PER DISCUSSIONS WITH STAFF, AREA WAS ADDED BETWEEN
 OPEN SPACES #1 AND #2 TO INCREASE SEPARATION. SEE
 ARCHITECTURAL SHEETS FOR REVISED LAYOUT OF THIS AREA;
 SHEET A1.0 SHOWS THIS CLEARLY.
 ZONING 11.17.22 ??? PARTIALLY SATISFIED (SEE NEW
 COMMENT #5)
  
 D. WHAT IS THE GROUND LEVEL PRIVATE OPEN SPACE AT THE
 NORTHWEST CORNER OF SHEET L-1? IS THIS PART OF THE
 REQUIRED PRIVATE OPEN SPACE COUNT? SUGGEST EXPANDING
 2BR UNIT TO SCREEN LOADING/SERVICE ROAD FROM THE
 PRIVATE OPEN SPACE AND N ROSEMARY.
  
 RESPONSE: THIS AREA IS NO LONGER DESIGNATED OPEN SPACE.
 SEE SHEET A1.0 FOR REVISED LAYOUT OF THIS AREA.
 ZONING 11.17.22 ??? PARTIALLY SATISFIED (SEE NEW
 COMMENT #5)
  
 RECOMMEND INCLUDING HEDGES ALONG ROSEMARY FRONTAGE TO
 SCREEN LOADING OPERATION
  
 E. PLEASE PROVIDE CALCULATIONS FOR HOW THE PROPOSED
 OPEN SPACES MEET THE REQUIREMENTS FOR SIZE, ACTIVE USE
 ABUTMENT, ROW ABUTMENT, SEATING, VEGETATION, OVERHEAD
 COVER, ETC. AS IS APPLICABLE.
  
  RESPONSE:
  SEE SHEET A1.4 FOR OPEN SPACE CALCULATIONS.
 ZONING 11.17.22 ??? PARTIALLY SATISFIED (SEE NEW
 COMMENT #5)
  
 7. PLEASE ADJUST GROSS BUILDING AREA (GBA) CALCULATIONS
 ON SHEET A0.2 AND A1.1:
  
 - GROSS BUILDING AREA MEANS THE TOTAL FLOOR AREA OF A
 BUILDING, INCLUDING AIR-CONDITIONED OR FULLY ENCLOSED
 STORAGE SPACES, ENCLOSED AREAS ON THE ROOFTOP, SUCH AS
 BATHROOMS AND LOBBIES, STAIRS AND ELEVATOR AREAS, AND
 EXTERNAL UNENCLOSED CIRCULATION AREAS. THE GROSS
 BUILDING AREA DOES NOT INCLUDE PARKING AREAS;
 UNENCLOSED COLONNADES, PORCHES AND BALCONIES;
 MECHANICAL AND ELECTRICAL SPACES; AND TRASH ROOMS.
 STORAGE SPACES WITHOUT WINDOWS AND ENCLOSED BY SURFACES
 THAT ALLOW FOR NATURAL VENTILATION OR OUTSIDE AIR
 CIRCULATION SHALL NOT BE INCLUDED.
  
  - THE GROSS BUILDING AREA SHALL BE MEASURED FROM THE
 OUTSIDE FACE OF EXTERIOR WALLS.
  
  - SHEET A1.1 AND A1.2 SHOULD MATCH IN TERMS OF TOTALS.
  
  RESPONSE:
 BECAUSE GROSS BUILDING AREA AND FAR ARE ESSENTIALLY THE
 SAME AREA DESIGNATION, TO CLARIFY AND REMOVE
 REDUNDANCY, ONLY FAR DIAGRAMS ARE SHOWN.
 ZONING 11.17.22 ??? SATISFIED
  
 8. SHEET A1.0 PLEASE PROVIDE ALL CURBCUT WIDTH
 DIMENSIONS ALONG PROPERTY LINE, CANNOT EXCEED 25???.
  
 RESPONSE: SEE SHEET A1.0 FOR CURB CUT DIMENSIONS.
 ZONING 11.17.22 ??? PARTIALLY SATISFIED
 MEASUREMENT FOR CURBCUT WIDTH IS TO BE TAKEN FROM
 INTERSECTION OF PROPERTY LINE WITH THE CURBCUT, PLEASE
 ADJUST.
  
 9. ON SHEET L-1 AND A1.0 STREETSCAPE AND LANDSCAPE
 REQUIREMENTS NOT MET:
  
 A. STREET TREES ARE REQUIRED TO BE ADJACENT TO THE
 CURB, N ROSEMARY AVENUE SIDE ON FEATURES 5 (EXISTING)
 TREES, REQUIREMENT IS TREES SPACED OUT AT A MAX. OF 30
 FT. ON CENTER; APPROX. 16 STREET TREES REQUIRED ALONG N
 ROSEMARY.
  
  RESPONSE: ALONG ROSEMARY AVE THE 8' SIDEWALK IS
 PROPOSED ADJACENT TO THE CURB SO THE STREET TREES ARE
 PROVIDED BETWEEN THE WALK AND THE BUILDING AT 30' O.C.
 THE 5 EXISTING TREES WILL BE REMOVED. CITY ALSO
 MENTIONED CRA WOULD BE DEVELOPING A STREETSCAPE ALONG
 ROSEMARY AVE. ONCE CRA PLANS ARE FINALIZED THE
 STREETSCAPE ALONG ROSEMARY SHALL BE MODIFIED TO
 INCORPORATE CRA DESIGN.
 ZONING 11.17.22 ??? NOT SATISFIED
 STREET TREES ARE REQUIRED TO BE PLANTED ADJACENT TO THE
 CURB PER SEC. 94-113. CITY STAFF HAS CONFIRMED WITH CRA
 THAT THE APPLICANT IS RESPONSIBLE FOR MEETING THE CITY
 STREETSCAPE REQUIREMENTS WITH THIS PROJECT PROPOSAL, AS
 FUTURE WORK AND DESIGN BY CRA/CITY NOT CONFIRMED.
 APPROX. 16 STREET TREES REQUIRED ALONG N ROSEMARY
  
 PLEASE ILLUSTRATE STREETSCAPE/LANDSCAPE ELEMENTS
 (STREET TREES, ETC.) WITHIN THE SITE PLAN A1.0
  
 B. FURTHER DISCUSSION IS NECESSARY WITH CRA AS THERE
 ARE PLANS TO RECONFIGURE THE N ROSEMARY STREETSCAPE.
  
 RESPONSE: MULTIPLE DISCUSSIONS WITH THE CRA HAVE BEEN
 HAD PRIOR TO FORMAL SUBMITTAL TO THE CITY. WE WILL
 CONTINUE TO COORDINATE WITH THE CRA REGARDING TIMING
 AND DESIGN OF IMPROVEMENTS ALONG ROSEMARY.
 ZONING 11.17.22 ??? ACKNOWLEDGED
 CITY STAFF HAS CONFIRMED WITH CRA THAT THE APPLICANT IS
 RESPONSIBLE FOR MEETING THE CITY STREETSCAPE
 REQUIREMENTS WITH THIS PROJECT PROPOSAL
  
 C. PLEASE ILLUSTRATE THE SITE VISIBILITY TRIANGLES
 FROM ALL INTERSECTIONS IN ACCORDANCE WITH SEC.
 94-305(E.) LANDSCAPE APPEARS TO IMPEDE.
  
  RESPONSE: VISIBILITY TRIANGLES SHOWN ON SHEET L-1.
 TREES ADJACENT TO TRIANGLES SHALL HAVE AN 8??? CT.
 ZONING 11.17.22 ??? NOT SATISFIED
 SHEET L-1 DOES NOT APPEAR TO PROVIDE SITE VISIBILITY
 TRIANGLES FOR 4TH ST. EXT ONTO WEST RAILROAD RD. OR FOR
 THE TWO SERVICE DRIVES.
  
 10. PLEASE PROVIDE SETBACK LINES ON ALL ELEVATIONS.
  
  RESPONSE: SEE SHEETS A3.1 AND A3.2 FOR REVISED
 ELEVATIONS.
  
 ZONING 11.17.22 ??? PARTIALLY SATISFIED
  
 SETBACKS PROVIDED
  
 SHEET A3.1 WEST ELEVATION DOES NOT SHOW BRIDGE
 CONNECTING TWO BUILDINGS
  
 SHEET A3.1 EAST ELEVATION SHOWS OPENINGS THROUGH THE
 2ND AND 3RD LEVELS, WHAT ARE THESE?
  
 SHEET A3.2 SOUTH ELEVATION GROUND LEVEL SHOWS GREYED
 OUT PORTION OVER ENTRY. PLEASE REVISE.
  
 11. PLEASE PROVIDE SEPARATE SHEETS ON FA??ADE
 ARTICULATION AND HOW THE PROJECT MEETS PLANAR BREAK
 REQUIREMENTS, TRANSPARENCY/FENESTRATION REQUIREMENTS,
 AND PROVIDE ADDITIONAL DETAILS FOR ANY PROJECTIONS,
 SCREENING, OR ARCHITECTURAL FEATURES.
  
  RESPONSE: SEE SHEETS A1.5 AND A1.6 FOR PLANAR BREAK
 AND TRANSPARENCY DIAGRAMS.
 ZONING 11.17.22 ??? NOT SATISFIED
 CLARIFICATION ??? FOR BUILDING FRONTAGES OF 150 FT. OR
 MORE NO FA??ADE SHALL EXCEED 60% OF FRONTAGE WITHOUT
 PROVIDING A PLANAR BREAK OF AT LEAST 3 FT. IN DEPTH,
 TOTAL WIDTH OF PLANAR BREAKS SHALL BE GREATER THAN OR
 EQUAL TO 20% OF BUILDING FRONTAGE.
  
 PLEASE PROVIDE PLANAR BREAK CALLOUTS AND DIMENSIONS FOR
 THE W RAILROAD AVE. SIDE, THE GARAGE ENTRY IS STILL
 PART OF THE OVERALL BUILDING AND PODIUM.
  
 WIDTH REQUIREMENTS APPEAR TO BE MET. PLEASE PROVIDE
 DEPTH OF PLANAR BREAKS (MINIMUM OF 3FT.)
  
 PLEASE CLARIFY OR EXPLAIN THE FA??ADE PLANE
 CALCULATIONS: GROUND FLOOR TABLE, WHAT DOES THIS MEAN
 OR SHOW?
  
 TRANSPARENCY REQUIREMENTS MET.
  
 12. THE WALLS ON THE INTERIOR OF THE PUBLIC OPEN SPACE
 COURTYARD (BETWEEN 4TH AND 3RD) ARE BLANK, PLEASE
 PROVIDE SOME FENESTRATION, ARCHITECTURAL TREATMENT OR
 FACADE ARTICULATION ON THESE WALLS. - NORTHERN FACADE
 OF THE BUILDING (FACING SALVATION ARMY) APPEARS TO HAVE
 A LARGE BLANK WALL (>20%) PLEASE PROVIDE ADDITIONAL
 FENESTRATION, ARCHITECTURAL TREATMENT OR FACADE
 ARTICULATION TO THIS FRONTAGE. - WEST RAILROAD AVENUE,
 GROUND LEVEL FACADE WOULD BENEFIT FROM ADDITIONAL
 ARTICULATION.
  
  RESPONSE: SEE SHEETS A3.1 AND A3.2 FOR REVISED
 ELEVATIONS.
 ZONING 11.17.22 ??? PARTIALLY SATISFIED
 INTERIOR WALLS OF THE PUBLIC OPEN SPACE COURTYARD
 APPEAR TO BE BLANK STILL WITHIN THE RENDERS PROVIDED.
 PLEASE PROVIDE CLARIFICATION ON IF THERE ARE ANY
 ARCHITECTURAL FEATURES, FENESTRATION, OR TREATMENTS ON
 THESE INSIDE WALLS. A2.1, A2.2, AND A2.3 SHOW
 DIFFERENCES IN FENESTRATION. ALSO A3.3 SHOWS WINDOWS
 AND FA??ADE ARTICULATION.
  
 13. BICYCLE PARKING REQUIRES 1 SPACE PER EVERY 100 FT.
 OF FRONTAGE, PUBLICLY ACCESSIBLE ALONG ROW/CURB (~5-6
 SPACES ON ROSEMARY; ~2 SPACES ON 3RD; ~3 SPACES ON W
 RAILROAD.)
  
  RESPONSE: SEE SHEET A1.0 FOR REVISED SITE PLAN SHOWING
 BICYCLE PARKING SPACES.
 ZONING 11.17.22 ??? PARTIALLY SATISFIED
 PLEASE PROVIDE DETAIL OF BIKE RACKS TO BE PLACED WITHIN
 ROW TO ENSURE IT MEETS CITY STANDARDS.
  
 14. PLEASE INDICATE LOCATION OF BIKE ROOM, PROVIDE
 DETAILS OF HOW ROOM IS ACCESSED, AND PROVIDE THE TYPE
 OF RACKS OR DETAIL HOW THE BIKES ARE SECURED WITHIN THE
 ROOM.
  
  RESPONSE: SEE SHEET A1.0 DESIGNED BICYCLE ROOMS IN
 EACH GARAGE. THE BICYCLE RACK DETAIL WILL BE PROVIDED
 IN THE PERMIT SET OF PLANS.
 ZONING 11.17.22 ??? PARTIALLY SATISFIED
 PLEASE PROVIDE DIMENSION OF BIKE ROOM TO VERY SPACE IS
 ADEQUATE FOR TYPE OF RACKS/SECURING METHODS PROPOSED.
 PLEASE PROVIDE A DETAIL OF BIKE RACKS TO ENSURE IT
 MEETS CITY STANDARDS.
  
  
 15. PLEASE PROVIDE PARKING STALL DETAILS, MAKE SURE
 THE STRIPING AND DIMENSIONS MEET CITY STANDARD. PLEASE
 PROVIDE DRIVE AISLE WIDTH, REQUIRED 24FT. MINIMUM.
 PLEASE PROVIDE PARKING RAMP SLOPES. PROVIDE DIMENSION
 OF LOADING AREA.
  
 RESPONSE: SEE SHEET A1.0 FOR TYPICAL STALL AND AISLE
 DIMENSIONS, PARKING SLOPES AND LOADING AREA SIZES.
 ZONING 11.17.22 ??? NOT SATISFIED
 PLEASE PROVIDE DIMENSIONS FOR ADA SPACES AND INCLUDE
 5??? ACCESS AISLE. PLEASE PROVIDE CONSISTENCY BETWEEN
 DRAWING SETS AND BE SURE THAT ALL ADA SPACES ARE
 ACCURATELY REPRESENTED BETWEEN SHEETS, SOME DRAWINGS
 HAVE THE SPACES MISSING.
  
 PLEASE CONSIDER ADDITIONAL ADA SPACES FOR GROUND FLOOR.
  
 ON SHEET A1.0, WHAT IS THE PATH OF ENTRY/EXIT FOR AN
 ADA USER WITHIN THE SOUTHERN BUILDING? THERE IS NO
 CLEAR ACCESS INTO THE BUILDING OR DIRECT CONNECTION TO
 ELEVATORS, PLEASE ADJUST.
  
 ARE ALL INTERNAL PARKING RAMPS 12% SLOPE?
  
 ADA SPACE ON SHEET A2.3 DOES NOT PROVIDE ACCESS AISLE
 OR CLEAR PATH TO ELEVATOR. CAN THIS BE RELOCATED?
  
 16. FOR DAC PLEASE PROVIDE ACCURATE AND FULL DETAIL
 RENDERS OF THE PROJECT.
  
  RESPONSE: ACKNOWLEDGED. RENDERING WILL BE PROVIDED.
 ZONING 11.17.22 ??? SATISFIED
 BE ACCURATE TO THE FINAL DESIGN OR PROPOSED PLANS
  
 17. CITY/CRA IN PARTNERSHIP WITH GEHL HAS PRODUCED A
 STUDY TO REDEVELOP N ROSEMARY AVENUE AND ITS
 STREETSCAPE, AS PART OF THIS STUDY N ROSEMARY IS TO BE
 A MORE ACTIVE FRONTAGE.
  
 A. CRA RECOMMEND INCORPORATING GROUND-LEVEL COMMERCIAL
  USES ALONG THE PORTION OF N. ROSEMARY AND THE 3RD ST.
 FRONTAGE OR CORNER. FROM 3RD ST. TO 4TH ST.
 COMMERCIAL/RETAIL OPPORTUNITIES FOR BOTH THE PROJECT'S
 RESIDENTS AS WELL AS THE SURROUNDING NEIGHBORHOOD.
  
 RESPONSE: AS WAS DISCUSSED WITH STAFF, WE HAVE CREATED
 ACTIVE USES ON THE GROUND FLOOR TO THE EXTENT POSSIBLE,
 INCLUDING BUT NOT LIMITED TO A DOUBLE-HEIGHT LIVE-WORK
 UNIT ON THE CORNER OF N. ROSEMARY AVE AND 3RD STREET.
 HOWEVER, AT THIS TIME, WE ARE CONCERNED WITH THE
 REQUEST TO ADD COMMERCIAL USES ALL ALONG ROSEMARY. THE
 CONCERN STEMS FROM THE CURRENT REALITY THAT THE STORE
 FRONTS WILL BE VACANT ??? PROVIDING NO VIBRANCY. TO THE
 CONTRARY, AS DESIGNED, THERE WILL BE ACTIVE USES FROM
 THE LIVE-WORK AS WELL AS CERTAIN RESIDENTIAL UNITS
 ABUTTING ROSEMARY. AS DESIGNED, THE DEVELOPMENT WILL
 PROVIDE MORE VIBRANCY THAN FORCED COMMERCIAL SPACES
 WITH NO TENANTS.
 ZONING 11.17.22 ??? SATISFIED
 CAN A RETAIL SPACE BE ACCOMODATED ON THE GROUND FLOOR
 OF 4TH ST. FRONTAGE WHERE CURRENTLY THERE ARE LARGE
 LOBBIES AND AMENITY ROOMS? BRINGS MORE ACTIVITY TO THE
 BUILDING AND PUBLIC OPEN SPACES.
  
 B. PORTION FROM 4TH ST. UP TO THE SALVATION ARMY
 PROPERTY LINE CAN REMAIN AS THE WALK-UP UNITS. HOWEVER
 ADDITIONAL GROUND-LEVEL RETAIL IS ENCOURAGED BY CRA.
  
 RESPONSE: AS DISCUSSED ABOVE, THE SEGMENT OF ROSEMARY
 IS NOT YET READY FOR VIABLE COMMERCIAL USES. AS
 DESIGNED, THE LIVE-WORK UNIT ALONG WITH WALK-UP UNITS
 ALONG ROSEMARY WILL PROVIDE THE DESIRED AND MUCH NEED
 VIBRANCY.
 ZONING 11.17.22 ??? SATISFIED
 SEE PREVIOUS SUGGESTION
  
 C. RELOCATE INTERIOR LOBBY TO THE INTERSECTION OF 4TH
 AND N ROSEMARY, MIRROR THE CONDITION ON THE 2ND
 BUILDING'S LOBBY.
  
 RESPONSE: THE SOUTH CORNER OF 4TH AND ROSEMARY IS
 CURRENTLY OCCUPIED BY UNITS. RELOCATING THE LOBBY TO
 THIS CORNER LOCATION WOULD, IN TURN, RELOCATE THOSE
 CORNER UNITS UNDER THE BRIDGE ELEMENT. THIS WOULD LIMIT
 NATURAL LIGHT FOR THOSE DWELLING UNITS.
 ZONING 11.17.22 ??? SATISFIED
 SEE PREVIOUS SUGGESTION
  
 D. SUGGEST FURTHER DISCUSSION WITH CRA.
  
 RESPONSE: AS DISCUSSED ABOVE, THE APPLICANT HAS AND
 WILL CONTINUE TO COORDINATE WITH THE CRA.
 ZONING 11.17.22 ??? SATISFIED
  
 18. RECOMMEND EXPLORING ADDITIONAL ARCHITECTURAL
 TREATMENTS, FACADE ARTICULATION, OR DESIGNS TO THE
 CORNER/INTERSECTION OF 3RD AND N ROSEMARY. THIS IS A
 FOCAL POINT AND SERVES AS A GATEWAY INTO THE NORTHWEST
 NEIGHBORHOOD, GREAT OPPORTUNITY TO MAKE A STANDOUT OR
 SPECIAL FRONTAGE.
  
  RESPONSE: SEE SHEETS A3.1 AND A3.2 FOR REVISED
 ELEVATIONS. CORNER OF 3RD AND ROSEMARY SHOWS A MORE
 ARTICULATED FA??ADE WITH RECESSED, DOUBLE-HEIGHT
 LIVE-WORK UNIT AND WRAP-AROUND BALCONY.
 ZONING 11.17.22 ??? NOT SATISFIED
 LANDSCAPE REMOVED FOR ADDITIONAL HARDSCAPE.
  
 PLEASE INCLUDE PEDESTRIAN CROSSINGS OVER ROSEMARY AND
 3RD STREET. PLEASE CONSIDER OPENING THIS CORNER UP
 MORE.
  
 RELOCATE MICROMOBILITY SPACE TO THE AREA UNDER THE
 BRIDGE IN FRONT OF AMENITY SPACE ON 4TH STREET.
 PROVIDES COVER AND FREES UP ADDITIONAL SPACE FOR
 LANDSCAPE, ETC.
  
 WILL THE LIVE-WORK UNIT PROVIDE ACCESS FROM 3RD STREET
 NOW INSTEAD OF THE PREVIOUS ROSEMARY ENTRY?
  
 19. ON SHEET A1.1 AND A1.2, THE DIAGRAM FOR LEVEL 4
 AND LEVEL 8 ARE MISSING, VALUES ARE SHOWN IN TABLE.
  
  RESPONSE: DIAGRAM LABELS UPDATED TO INCLUDE MISSING
 LEVELS.
 ZONING 11.17.22 ??? SATISFIED
  
 20. SHEET A2.3 THE BRIDGE SPANNING OVER 4TH ST. SHOWS
 PARKING SPACES, HOWEVER THERE ARE SEVERAL WALLS DRAWN,
 PLEASE CLARIFY HOW THIS BRIDGE/SPACE FUNCTIONS. WHAT IS
 THE GREY ROOM TO THE LEFT OF THE BRIDGE PARKING; IS
 THIS STORAGE?
  
 RESPONSE: PARKING SPACES ACROSS 4TH STREET ON LEVELS 3
 AND 4. SEE SHEET A2.3 FOR REVISED LAYOUT WITH WALLS
 REMOVED.
 ZONING 11.17.22 ??? SATISFIED
  
 21. SHEET A4.1 & A4.2, PLEASE EXPLAIN OR CLARIFY HOW
 THE BRIDGE AND PARKING LEVELS RELATE TO THE OVERALL
 FLOOR PLATES OF THE BUILDING, DOES NOT APPEAR TO BE
 LEVEL/LOOKS TO BE A HALF OR QUARTER-FLOOR DIFFERENCE IN
 THE ALIGNMENT. HOW DOES THIS SPACE FUNCTION IN RELATION
 TO THE OVERALL BUILDING? INTERNALLY RAMPS UP?
  
 RESPONSE: PARKING IS ORGANIZED IN A SPLIT-LEVEL
 ARRANGEMENT. ONE PART OF THE GARAGE ALIGNED TO THE MAIN
 HABITABLE LEVEL; THE OTHER PART IS MIDWAY BETWEEN MAIN
 HABITABLE LEVELS. THE BRIDGE LEVELS HAVE BEEN REWORKED
 TO ALIGN WITH THE MAIN HABITABLE LEVELS.
 ZONING 11.17.22 ??? NOT SATISFIED
 SECTION DRAWINGS NEED TO BE CLEANED UP OR CLARIFIED
 FURTHER. THERE ARE MANY INSTANCES DPOUBLE SLAB LINES,
 WHERE THE SLAB UNDULATES OR VARIES BETWEEN LEVELS, AND
 IT IS NOT CLEAR HOW THE SPACES RELATE TO THE FLOOR
 PLANS.
  
 SECTION A ON SHEET A4.1: THE BRIDGE BETWEEN THE TWO
 BUILDINGS SHOWS A WHITE BOX/ROOM LABELED PARKING, BUT
 THIS SPACE DOES NOT EXIST ON THE 3RD FLOOR PLAN, THIS
 IS AN AMENITY SPACE. THE RELATIONSHIP BETWEEN THE TWO
 PARKING LEVELS BETWEEN THE BRIDGE IS NOT CLEAR.
  
 SECTION A ON SHEET A4.1: DOES THE LOADING BAY RAMP UP
 INTO THE GARAGE? THE CHANGE IN SLABS IS CONFUSING.
 IT???S UNDERSTOOD THAT THE NORTHERN PORTION OF THE
 PARKING STRUCTURE HAS A HALF LEVEL STEP DOWNWARD, BUT
 IS THE REST OF THE PARKING AND LOADING ON A SLAB ABOVE
 GRADE? WHY ARE THERE TWO DIFFERENT FLOOR SLABS?
  
 SECTION A ON SHEET A4.1: PLEASE CLEAN UP OR CLARIFY
 WHAT IS HAPPENING ON THE 4TH STREET PORTION OF THE
 SECTION, TWO SEPARATE LINES INDICATING THE FLOOR OF THE
 BUILDING AND ROADWAY.
  
 SECTION A ON SHEET A4.1: PLEASE CLARIFY DOES THE
 SOUTHERN BUILDING STEP DOWN IN THE PARKING GARAGE? TWO
 DIFFERENT FLOOR SLABS AND ELEVATIONS SHOW BETWEEN
 PARKING LEVEL AND REST OF BUILDING/SIDEWALK.
  
 SECTION B ON SHEET A4.1: CLARIFY THE TWO BOLDED LINES
 FOR THE FLOOR ELEVATION/SLAB AND SIDEWALK/AT GRADE
 LEVEL.
  
 SECTION C AND D ON SHEET A4.2: PLEASE CLARIFY THE
 GROUND LEVEL CONDITIONS, TWO SEPARATE BOLD LINES SHOWN
 AGAIN, WHAT IS THE FINISHED FLOOR ELEVATION AND ARE
 THERE ADDITIONAL STEPS DOWN/UP FOR THE GROUND LEVEL?
  
 PLEASE PROVIDE FINISHED FLOOR ELEVATIONS, OR LEADERS ON
 THE DRAWINGS AND INDICATE AREAS WITH ANY STEPS OR
 RAMPS.
  
 22. UPDATED RENDERS PROVIDED ON 9.8.22 SHOW THE
 GROUND-LEVEL WALKUP UNITS ENCLOSED BY A RAILING OR
 FENCE, WHAT IS THE TOTAL HEIGHT OF THE WALL + RAILING?
  
 RESPONSE: THE HEIGHTS OF THE WALLS WILL VARY DEPENDING
 ON THE SIDEWALK???S RELATIONSHIP TO THE ADJACENT
 WALK-UP GARDEN FINISH FLOOR ELEVATION (A DIFFERENCE OF
 APPROX. 2??? ??? 3.5???). THE RAILING WILL BE 42???
 ABOVE THE TOP OF THE WALL.
 ZONING 11.17.22 ??? NOT SATISFIED
 PER SECTION 94-109 WALK-UP GARDEN: FENCES, WALLS OR
 OTHER SIMILAR STRUCTURES SHALL NOT EXCEED FOUR FEET IN
 HEIGHT. PLEASE REFER TO FIGURE IV-34.
  
 PLEASE PROVIDE A DETAIL OF THE WALK-UP UNITS SPECIFYING
 THE DIMENSIONS OF THE DIFFERENT ELEVATION CHANGES,
 FLOOR LEVELS, WALLS/FENCE, AND PROJECTIONS AS IS
 APPLICABLE.
  
 BE SURE RENDERS ARE ACCURATE TO PLANS.
  
 23. PER CONVERSATION WITH HISTORIC PRESERVATION STAFF,
 WHILE THE PROJECT LIES OUTSIDE OF THE BOUNDARIES FOR
 THE NORTHWEST NEIGHBORHOOD, STAFF ENCOURAGES DESIGN
 THAT PROVIDES RELATIONSHIP OR REFERENCE TO THE HISTORIC
 NATURE OF THE NEIGHBORHOOD THIS PROJECT FACES/OPENS TO.
 ADDITIONAL ARCHITECTURAL ELEMENTS TO CONSIDER INCLUDE:
 ANGLED CORNERS ON THE BALCONIES CONNECTING TO THE
 BUILDING FACADE (CREATING A TRAPEZOID LOOK), CABLED
 SUPPORTS FROM THE BALCONIES TO THE BUILDING FA??ADE
 (MIMIC AWNING OR CANOPY SUPPORTS), A THICKER BALCONY
 SLAB FOR THE BALCONY ABOVE THE 3RD ST. ACCESS ROAD
 (CREATING MORE OF A MARQUEE ELEMENT), AND OPENING UP
 THE CORNER OF 3RD AND N ROSEMARY BY SETTING THE MASS
 BACK AND CREATING A FOCAL POINT AT THE CORNER.
  
 RESPONSE: THE TREATMENT OF THE CORNER OF 3RD AND
 ROSEMARY HAS BEEN REVISED TO SHOW ADDITIONAL
 WRAP-AROUND BALCONIES, A STRONG FRAMING ELEMENT, A
 RECESSED VOLUME ON THE GROUND FLOOR AND MORE OPEN SPACE
 IN FRONT.
  
 ZONING 11.17.22 ??? SATISFIED
 RENDERS PROVIDED DO NOT ACCURATELY REFLECT CHANGES TO
 SITE PLAN OR ELEVATIONS OR THE RENDER IN SHEET A5.1.
 PLEASE ADDRESS PRIOR TO DAC.
  
  
  
 NEW COMMENTS 11/18/22:
  
 1. PLEASE ILLUSTRATE ALL ENTRY/EXIT AND DOORS ON THE
 GROUNDLEVEL AND UPPER FLOOR PLANS TO CLARIFY USER
 CIRCULATION AND ACCESS THROUGHOUT THE BUILDING.
  
 2. MAX FOOTPRINT LENGTH PERMITTED FOR NWD-8 SUBDISTRICT
 IS 250???, PROPOSED SOUTH BUILDING EXCEEDS MAX LENGTH
 AT 265???. PLEASE ADDRESS/ADJUST.
  
 3. SHEET A0.2 TABLE 5 NEEDS TO BE ADJUSTED. SHOULD
 REFLECT SHEET A1.5 CALCULATIONS AND DESCRIPTION/LABEL.
  
 4. PLEASE MOVE THE TREES TO BE ADJACENT TO THE CURB
 ALONG THE 4TH ST. EXTENSION, THESE SHALL SERVE AS THE
 REQUIRED STREET TREES (MAX. 30 FT ON CENTER). PLEASE
 ALSO INCLUDE TREES ON BOTH SIDES OF 4TH ST, CONTINUOUS
 SHADE FOR PEDESTRIANS.
  
 5. THE TWO ADJACENT PUBLIC OPEN SPACES ALONG 4TH STREET
 STILL LOOK AND READ AS ONE LINEAR SPACE. ISSUE IS THAT
 NO PUBLIC SPACE CAN HAVE 1 SIDE 5X THE LENGTH OF THE
 OTHERS. THE PUBLIC OPEN SPACE ALSO SEEMS TO SERVE THE
 GROUND LEVEL UNITS MORE THAN GENERAL PUBLIC, MOVING THE
 TREES TO THE CURB MAY HELP OPEN THE SPACE UP. STAFF
 ALSO SUGGESTS THAT THE UNITS THAT ARE FACING THE
 INTERSECTION OF W. RAILROAD AVE AND 4TH ST SHIFT
 SLIGHTLY OR CHANGE IN DIMENSION. CREATE MORE OF AN OPEN
 COURTYARD SPACE RATHER THAN A LINEAR ONE. ADDITIONALLY
 A PORTION OF THE OPEN SPACE CAN BE UNDER THE OVERHEAD
 BRIDGE (MAX. 20% OVERHEAD COVERAGE) TO PROVIDE
 ADDITIONAL SEPARATION BETWEEN TWO PUBLIC OPEN SPACES.
  
 6. PLEASE PROVIDE PEDESTRIAN CROSSINGS AND ADA RAMPS
 ALONG THE INGRESS/EGRESS OF 4TH ST. EXTENSION. AS WELL
 AS AT THE CORNER OF 3RD AND ROSEMARY.
  
 7. PLEASE PROVIDE A PHOTOMETRIC PLAN FOR THE PROJECT
 SITE, REQUIREMENT IS A MINIMUM OF 0.6 FOOTCANDLES AS
 MEASURED AT THE BACK EDGE OF THE CURB AND ONE FOOT
 ABOVE THE SIDEWALK. ADDITIONALLY PLEASE PROVIDE A
 DETAIL AND SPECS OF THE PROPOSED LIGHT FIXTURES. CITY
 STANDARD FOR DECORATIVE STREET LAMPS IS THE LUMEC
 S55-007)
  
  
  
 CHRIS KIMMERLY, AICP
 URBAN DESIGN PLANNER
 822.1426 [email protected]
  

Review Stop Z ZONING
Rev No 1 Status F Date 09-07-2022 Cont ID  
Sent By ckimmerl Date 09-07-2022 Time 15:32 Rev Time 0.00
Received By ckimmerl Date 09-07-2022 Time 15:29 Sent To  
Notes
2022-09-07 15:31:021. ACTIVE USE: PLEASE NOTE THAT ACTIVE USES ARE
 REGULATED AS A PERCENTAGE OF THE BUILDABLE LOT
 FRONTAGE, NOT THE BUILDING FRONTAGE. PLEASE ADJUST
 CALCULATIONS ACCORDINGLY. THE PERCENTAGE SHOULD BE 80%
 OF THE ENTIRE N ROSEMARY AVE. PROPERTY LINE (60% FOR
 LINERS 2-5), 30% OF THE 3RD ST. PROPERTY LINE, AND THEN
 30% OF THE W. RAILROAD AVE. PROPERTY LINE.
  
 2. PLEASE PROVIDE OWNERS CONSENT OR PROOF OF AGREEMENT
 BETWEEN THE NEIGHBORING PROPERTY OWNER OF 411 W
 RAILROAD AVE. TO ALLOW FOR THE EXTENSION OF 4TH ST.
 OVER THEIR PROPERTY.
  
 3. RADIUS OF THE CURB-CUT OR APRON FOR THE NORTHERN
 SERVICE ACCESS ENCROACHES INTO CITY PROPERTY, PLEASE
 ADJUST.
  
 4. THE SERVICE ACCESS ALONG THE SOUTHERN AND NORTHERN
 SIDE OF THE PROPERTY DOES NOT PROVIDE REQUIRED 5 FT.
 LANDSCAPE BUFFER ALONG THE PROPERTY LINE AND TO SCREEN
 THE VEHICULAR USES. SERVICE ROADS WILL HAVE TO BE
 ADJUSTED TO ACCOMMODATE FOR THE BUFFER.
  
 5. SHEET A0.2 ? SITE INFORMATION TABLES REQUIRE
 CORRECTIONS:
 - IF LOT AREA IS 108,638; THEN WITH A 2.75 FAR MAXIMUM
 ALLOWED IS 298,755 SF, NOT 298,729 SF.
 - REQUIRED PRIVATE OPEN SPACE AT 25% IS 27,160 SF, NOT
 27,158 SF.
 - CONDITIONAL 50? SETBACK IS FROM ABOVE THE 5TH FLOOR,
 NOT THE 6TH.
 - GBA SHOULD MATCH FAR CALCULATION.
 - PLEASE DOUBLE CHECK ALL CALCULATIONS AND DIMENSIONS
 FOR CONSISTENCY ACROSS PLANS.
  
 6. OPEN SPACE REQUIREMENT:
 - PLEASE CLARIFY THE 4TH ST. EXTENSION. IS IT A PRIVATE
 ROAD WITH PUBLIC ACCESS AGREEMENT/EASEMENT? DOES IT
 SERVE AS A PUBLIC ROW?
 - IF 4TH ST. IS AN EXTENSION OF THE PUBLIC ROW, THEN IT
 REQUIRES A SETBACK ON EITHER SIDE AND SHOULD BE
 DESIGNED WITH STREETSCAPE REQUIREMENTS IN MIND. IF IT
 IS NOT CONSIDERED A PUBLIC ROW, THEN PUBLIC OPEN SPACE
 #2 DOES NOT MEET REQUIREMENT OF A COURTYARD TO HAVE
 PUBLIC ROW ABUTMENT. PUBLIC OPEN SPACES SHOULD NOT BE
 LOCATED ALONG THE PRIVATE DRIVE AS THAT IS NOT THE
 INTENTION OF THE CODE, SPACES SHOULD BE PUBLICALLY
 ACCESSIBLE AND VISIBLE; OTHERWISE, PEDESTRIANS WILL NOT
 UTILIZE THE SPACE AS DESIGNED.
 - ON SHEET A1.4 PUBLIC OPEN SPACE #1 AND #2 SHOULD BE
 COMBINED INTO A SINGLE SPACE, THE WALKWAY/SIDEWALK DOES
 NOT DELINEATE SEPARATE SPACES, AS IT IS SHOWN THE OPEN
 SPACE WOULD HAVE TO HAVE ITS PROPORTIONS CHANGED AS NO
 SINGLE SIDE CAN BE 5X THE LENGTH OF THE OTHER. THIS IS
 A VERY LINEAR OPEN SPACE.
 - WHAT IS THE GROUND LEVEL PRIVATE OPEN SPACE AT THE
 NORTH WEST CORNER OF SHEET L-1? IS THIS PART OF THE
 REQUIRED PRIVATE OPEN SPACE COUNT? SUGGEST EXPANDING
 2BR UNIT TO SCREEN LOADING/SERVICE ROAD FROM THE
 PRIVATE OPEN SPACE AND N ROSEMARY.
 - PLEASE PROVIDE CALCULATIONS FOR HOW THE PROPOSED OPEN
 SPACES MEET THE REQUIREMENTS FOR SIZE, ACTIVE USE
 ABUTMENT, ROW ABUTMENT, SEATING, VEGETATION, OVERHEAD
 COVER, ETC. AS IS APPLICABLE.
  
 7. PLEASE ADJUST GROSS BUILDING AREA (GBA) CALCULATIONS
 ON SHEET A0.2 AND A1.1:
 - GROSS BUILDING AREA MEANS THE TOTAL FLOOR AREA OF A
 BUILDING, INCLUDING AIR-CONDITIONED OR FULLY ENCLOSED
 STORAGE SPACES, ENCLOSED AREAS ON THE ROOFTOP, SUCH AS
 BATHROOMS AND LOBBIES, STAIRS AND ELEVATOR AREAS, AND
 EXTERNAL UNENCLOSED CIRCULATION AREAS. THE GROSS
 BUILDING AREA DOES NOT INCLUDE PARKING AREAS;
 UNENCLOSED COLONNADES, PORCHES AND BALCONIES;
 MECHANICAL AND ELECTRICAL SPACES; AND TRASH ROOMS.
 STORAGE SPACES WITHOUT WINDOWS AND ENCLOSED BY SURFACES
 THAT ALLOW FOR NATURAL VENTILATION OR OUTSIDE AIR
 CIRCULATION SHALL NOT BE INCLUDED.
 - THE GROSS BUILDING AREA SHALL BE MEASURED FROM THE
 OUTSIDE FACE OF EXTERIOR WALLS.
 - SHEET A1.1 AND A1.2 SHOULD MATCH IN TERMS OF TOTALS.
  
 8. SHEET A1.0 PLEASE PROVIDE ALL CURBCUT WIDTH
 DIMENSIONS ALONG PROPERTY LINE, CANNOT EXCEED 25?.
  
 9. ON SHEET L-1 AND A1.0 STREETSCAPE AND LANDSCAPE
 REQUIREMENTS NOT MET:
 - STREET TREES ARE REQUIRED TO BE ADJACENT TO THE CURB,
 N ROSEMARY AVENUE SIDE ON FEATURES 5 (EXISTING) TREES,
 REQUIREMENT IS TREES SPACED OUT AT A MAX. OF 30 FT. ON
 CENTER; APPROX. 16 STREET TREES REQUIRED ALONG N
 ROSEMARY.
 - FURTHER DISCUSSION IS NECESSARY WITH CRA AS THERE ARE
 PLANS TO RECONFIGURE THE N ROSEMARY STREETSCAPE.
 - PLEASE ILLUSTRATE THE SITE VISIBILITY TRIANGLES FROM
 ALL INTERSECTIONS IN ACCORDANCE WITH SEC. 94-305(E.) ?
 LANDSCAPE APPEARS TO IMPEDE.
  
 10. PLEASE PROVIDE SETBACK LINES ON ALL ELEVATIONS.
  
 11. PLEASE PROVIDE SEPARATE SHEETS ON FACADE
 ARTICULATION AND HOW THE PROJECT MEETS PLANAR BREAK
 REQUIREMENTS, TRANSPARENCY/FENESTRATION REQUIREMENTS,
 AND PROVIDE ADDITIONAL DETAILS FOR ANY PROJECTIONS,
 SCREENING, OR ARCHITECTURAL FEATURES.
  
 12. THE WALLS ON THE INTERIOR OF THE PUBLIC OPEN SPACE
 COURTYARD (BETWEEN 4TH AND 3RD) ARE BLANK, PLEASE
 PROVIDE SOME FENESTRATION, ARCHITECTURAL TREATMENT OR
 FACADE ARTICULATION ON THESE WALLS.
 - NORTHERN FA?ADE OF THE BUILDING (FACING SALVATION
 ARMY) APPEARS TO HAVE A LARGE BLANK WALL (>20%) PLEASE
 PROVIDE ADDITIONAL FENESTRATION, ARCHITECTURAL
 TREATMENT OR FACADE ARTICULATION TO THIS FRONTAGE.
 - WEST RAILROAD AVENUE, GROUND LEVEL FACADE WOULD
 BENEFIT FROM ADDITIONAL ARTICULATION.
  
 13. BICYCLE PARKING REQUIRES 1 SPACE PER EVERY 100 FT.
 OF FRONTAGE, PUBLICLY ACCESSIBLE ALONG ROW/CURB (~5-6
 SPACES ON ROSEMARY; ~2 SPACES ON 3RD; ~3 SPACES ON W
 RAILROAD.)
  
 14. PLEASE INDICATE LOCATION OF BIKE ROOM, PROVIDE
 DETAILS OF HOW ROOM IS ACCESSED, AND PROVIDE THE TYPE
 OF RACKS OR DETAIL HOW THE BIKES ARE SECURED WITHIN THE
 ROOM.
  
 15. PLEASE PROVIDE PARKING STALL DETAILS, MAKE SURE THE
 STRIPING AND DIMENSIONS MEET CITY STANDARD. PLEASE
 PROVIDE DRIVE AISLE WIDTH, REQUIRED 24FT. MINIMUM.
 PLEASE PROVIDE PARKING RAMP SLOPES. PROVIDE DIMENSION
 OF LOADING AREA.
  
 16. FOR DAC PLEASE PROVIDE ACCURATE AND FULL DETAIL
 RENDERS OF THE PROJECT.
  
 17. CITY/CRA IN PARTNERSHIP WITH GEHL HAS PRODUCED A
 STUDY TO REDEVELOP N ROSEMARY AVENUE AND ITS
 STREETSCAPE, AS PART OF THIS STUDY N ROSEMARY IS TO BE
 A MORE ACTIVE FRONTAGE.
 - CRA RECOMMEND INCORPORATING GROUND-LEVEL COMMERCIAL
 USES ALONG THE PORTION OF N. ROSEMARY AND THE 3RD ST.
 FRONTAGE OR CORNER. FROM 3RD ST. TO 4TH ST.
 COMMERCIAL/RETAIL OPPORTUNITIES FOR BOTH THE PROJECT'S
 RESIDENTS AS WELL AS THE SURROUNDING NEIGHBORHOOD.
 - PORTION FROM 4TH ST. UP TO THE SALVATION ARMY
 PROPERTY LINE CAN REMAIN AS THE WALK-UP UNITS. HOWEVER
 ADDITIONAL GROUND-LEVEL RETAIL IS ENCOURAGED BY CRA.
 - RELOCATE INTERIOR LOBBY TO THE INTERSECTION OF 4TH
 AND N ROSEMARY, MIRROR THE CONDITION ON THE 2ND
 BUILDING'S LOBBY.
 - SUGGEST FURTHER DISCUSSION WITH CRA.
  
 18. RECOMMEND EXPLORING ADDITIONAL ARCHITECTURAL
 TREATMENTS, FACADE ARTICULATION, OR DESIGNS TO THE
 CORNER/INTERSECTION OF 3RD AND N ROSEMARY. THIS IS A
 FOCAL POINT AND SERVES AS A GATEWAY INTO THE NORTHWEST
 NEIGHBORHOOD, GREAT OPPORTUNITY TO MAKE A STANDOUT OR
 SPECIAL FRONTAGE.
  
 19. ON SHEET A1.1 AND A1.2, THE DIAGRAM FOR LEVEL 4 AND
 LEVEL 8 ARE MISSING, VALUES ARE SHOWN IN TABLE.
  
 20. SHEET A2.3 THE BRIDGE SPANNING OVER 4TH ST. SHOWS
 PARKING SPACES, HOWEVER THERE ARE SEVERAL WALLS DRAWN,
 PLEASE CLARIFY HOW THIS BRIDGE/SPACE FUNCTIONS. WHAT IS
 THE GREY ROOM TO THE LEFT OF THE BRIDGE PARKING; IS
 THIS STORAGE?
  
 21. SHEET A4.1 & A4.2, PLEASE EXPLAIN OR CLARIFY HOW
 THE BRIDGE AND PARKING LEVELS RELATE TO THE OVERALL
 FLOOR PLATES OF THE BUILDING, DOES NOT APPEAR TO BE
 LEVEL/LOOKS TO BE A HALF OR QUARTER-FLOOR DIFFERENCE IN
 THE ALIGNMENT. HOW DOES THIS SPACE FUNCTION IN RELATION
 TO THE OVERALL BUILDING? INTERNALLY RAMPS UP?
  
 22. UPDATED RENDERS PROVIDED ON 9.8.22 SHOW THE
 GROUND-LEVEL WALKUP UNITS ENCLOSED BY A RAILING OR
 FENCE, WHAT IS THE TOTAL HEIGHT OF THE WALL + RAILING?
  
 23. PER CONVERSATION WITH HISTORIC PRESERVATION STAFF,
 WHILE THE PROJECT LIES OUTSIDE OF THE BOUNDARIES FOR
 THE NORTHWEST NEIGHBORHOOD, STAFF ENCOURAGES DESIGN
 THAT PROVIDES RELATIONSHIP OR REFERENCE TO THE HISTORIC
 NATURE OF THE NEIGHBORHOOD THIS PROJECT FACES/OPENS TO.
 ADDITIONAL ARCHITECTURAL ELEMENTS TO CONSIDER INCLUDE:
 ANGLED CORNERS ON THE BALCONIES CONNECTING TO THE
 BUILDING FA?ADE (CREATING A TRAPEZOID LOOK), CABLED
 SUPPORTS FROM THE BALCONIES TO THE BUILDING FA?ADE
 (MIMIC AWNING OR CANOPY SUPPORTS), A THICKER BALCONY
 SLAB FOR THE BALCONY ABOVE THE 3RD ST. ACCESS ROAD
 (CREATING MORE OF A MARQUEE ELEMENT), AND OPENING UP
 THE CORNER OF 3RD AND N ROSEMARY BY SETTING THE MASS
 BACK AND CREATING A FOCAL POINT AT THE CORNER.
  
 CHRIS KIMMERLY, AICP
 URBAN DESIGN PLANNER
 822.1426 [email protected]
  