Plan Review Details - Project Z22020019
| Plan Review Stops For Project Z22020019 |
| Review Stop |
AIPP |
ART IN PUBLIC PLACES |
| Rev No |
1 |
Status |
F |
Date |
03-10-2022 |
|
|
Cont ID |
|
| Sent By |
scwelter |
Date |
03-10-2022 |
Time |
12:05 |
Rev Time |
0.00 |
| Received By |
swelter |
Date |
09-20-2022 |
Time |
15:46 |
Sent To |
|
|
| Notes |
| 2022-09-20 15:45:54 | 8.24.2022 COMPLETED ART ASSESSMENT APPLICATION OPTION | | | #1 ART ON SITE - SITE PLAN NEEDS TO BE UPDATED AND | | | INCLUDE IDENTIFIED AREA(S) FOR PUBLIC ART FOR SITE PLAN | | | APPROVAL. | | | THE SPACE IS TIGHT, AND INCLUSION OF ART WILL BE | | | CHALLENGING. IT IS RECOMMENDED THAT OPTION #2 BE | | | CONSIDERED. | | | | | 2022-03-10 12:06:07 | TOTAL CONSTRUCTION COSTS OF THIS DEVELOPMENT ARE OVER | | | $500,000 IT IS SUBJECT TO THE PUBLIC ART REQUIREMENT AS | | | PER CITY ORDINANCE. | | | SECTION 78-129: ALL PRIVATE DEVELOPMENT PROJECTS, | | | INCLUDING NEW CONSTRUCTION, OR THE RENOVATION OR | | | IMPROVEMENT OF AN EXISTING BUILDING, WHERE TOTAL | | | CONSTRUCTION COSTS ARE EQUAL TO OR GREATER THAN | | | $500,000 ARE SUBJECT TO THE PUBLIC ART REQUIREMENT. | | | OPTION 1: INSTALL ARTWORK ON THE DEVELOPMENT SITE | | | VALUED IN AN AMOUNT NOT LESS THAN ONE PERCENT OF THE | | | TOTAL CONSTRUCTION COSTS; OR | | | OPTION 2: CONTRIBUTE AN AMOUNT EQUAL TO 75 PERCENT OF | | | ONE PERCENT OF THE TOTAL CONSTRUCTION COSTS FOR DEPOSIT | | | TO THE PUBLIC ART ACCOUNT. | | | A COMPLETED PUBLIC ART ASSESSMENT APPLICATION IS | | | REQUIRED AT TIME OF BUILDING PERMIT SUBMITTAL. | | | | | | CONTACT SYBILLE WELTER, ADMINISTRATOR OF PUBLIC ART & | | | CULTURE AT [email protected] TO OBTAIN AN ART ASSESSMENT | | | APPLICATION AND REVIEW THE REQUIREMENTS. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
03-09-2022 |
|
|
Cont ID |
|
| Sent By |
rbrown |
Date |
03-09-2022 |
Time |
20:10 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
03-09-2022 |
Time |
20:10 |
Sent To |
|
|
| Notes |
| 2022-03-09 20:15:43 | DEVELOPMENT SERVICES DEPARTMENT, BUILDING DIVISION, | | | COMMENTS: | | | | | | 1. THIS REVIEW IS A CURSORY REVIEW AS IT RELATES TO THE | | | SITE. IT IS NOT A REVIEW FOR FULL COMPLIANCE WITH | | | FLORIDA BUILDING CODE. THE FOLLOWING COMMENTS ARE TO BE | | | ADDRESSED FOR THE BUILDING PERMIT APPLICATION. | | | | | | 2. VAN ACCESSIBLE PARKING SPACES. SITE PLAN, SHEET A-1, | | | DOES NOT SHOW THAT THE ACCESSIBLE PARKING SPACE WILL BE | | | VAN ACCESSIBLE. PER SECTION 208.2.4 OF FLORIDA | | | ACCESSIBILITY CODE, ONE IN EVERY SIX REQUIRED | | | ACCESSIBLE SPACES (AT LEAST ONE) IN A PARKING | | | STRUCTURE, SHALL BE ?VAN ACCESSIBLE? AND DESIGNED IN | | | ACCORDANCE WITH SECTION OF 502 OF FLORIDA ACCESSIBILITY | | | CODE (VERTICAL CLEARANCE NOT LESS THAN 98 INCHES AT | | | SPACE AND VEHICULAR ACCESS ROUTE) | | | | | | 3. ELECTRIC VEHICLE CHARGING STATION. IF ELECTRIC | | | VEHICLE (EV) CHARGING STATIONS ARE PROVIDED AT LEAST 1 | | | IN 25 MUST COMPLY WITH ACCESSIBLE PARKING SPACE | | | REQUIREMENTS. | | | | | | 4. BUILDING SIZE. WHEN SUBMITTED FOR BUILDING PERMIT, | | | THE PLANS SHALL SHOW THAT THE TYPE OF CONSTRUCTION FOR | | | THE BUILDINGS WILL BE IN ACCORDANCE WITH THE HEIGHT, | | | AREA AND OCCUPANCY LIMITATIONS IN CHAPTER 5 OF THE | | | FLORIDA BUILDING CODE. | | | | | | 5. BUILDING LOCATION RELATIVE TO THE PROPERTY LINE AND | | | OTHER STRUCTURES. WHEN SUBMITTED FOR BUILDING PERMIT, | | | COMPLIANCE WITH ALL BUILDING SEPARATION, PERCENTAGE OF | | | OPENINGS AND OPENING PROTECTIVE REQUIREMENTS OF | | | CHAPTERS 6 AND 7 OF THE FLORIDA BUILDING CODE SHALL BE | | | VERIFIED. | | | | | | 6. ENCLOSED PARKING GARAGES. IF THE PARKING GARAGE DOES | | | NOT HAVE WALL OPENINGS, OR SUFFICIENT WALL OPENINGS TO | | | MEET THE DEFINITION OF AN OPEN PARKING GARAGE, IT WILL | | | BE CONSIDERED AN ENCLOSED PARKING GARAGE AND MUST HAVE | | | EXHAUST SYSTEMS. THE EXHAUST SYSTEMS SHALL BE DESIGNED | | | TO MINIMIZE NOISE LEVELS USING INLINE FAN SILENCERS OR | | | OTHER APPROVED METHODS. | | | | | | 7. GREASE INTERCEPTOR. IF ANY OF THE RETAIL SPACES WILL | | | BE RESTAURANT USE, A GREASE INTERCEPTOR WILL BE | | | REQUIRED. FOR INFORMATION ON THE REQUIRED TYPE, SIZE | | | AND LOCATION, PLEASE CONTACT RYAN BROWN, CHIEF PLUMBING | | | INSPECTOR, DEVELOPMENT SERVICES DEPARTMENT, AT (561) | | | 805-6692, OR BY EMAIL: [email protected] | | | | | | 8. SEPARATE PERMITS REQUIRED. ALL APPLICABLE PERMITS | | | AND SUB-PERMITS MUST BE OBTAINED BEFORE COMMENCING THE | | | WORK. SEPARATE PERMITS, PLANS AND FEES, ARE REQUIRED | | | FOR SIGNS, SWIMMING POOLS AND SPAS, GAS SYSTEMS, | | | GENERATORS, FIRE ALARM SYSTEMS, FIRE SPRINKLER AND | | | OTHER FIRE SUPPRESSION SYSTEMS, GREASE INTERCEPTORS, | | | SITE LIGHTING, SITE LANDSCAPE, SITE IRRIGATION, ETC. | | | | | | 9. CONTRACTOR VEHICLE PARKING. PROPERTY OWNER AND | | | CONTRACTOR SHALL MAKE ARRANGEMENTS FOR PARKING OF | | | CONTRACTOR VEHICLES TO MINIMIZE THE IMPACT ON ALL | | | NEIGHBORING PROPERTIES. | | | | | | 10. PROTECTION OF NEIGHBORING PROPERTY. PROPERTY OWNER | | | AND CONTRACTOR SHALL PROTECT ALL NEIGHBORING PROPERTY, | | | INCLUDING VEHICLES, FROM DAMAGE OR DIRT CAUSED BY THE | | | CONSTRUCTION, AND SHALL NOTIFY THE OCCUPANTS OF | | | NEIGHBORING PROPERTIES ABOUT ALL STAGES OF CONSTRUCTION | | | THAT MAY AFFECT THE USE OF THEIR PROPERTY. | | | | | | 11. BUILDING ADDRESS. EACH SEPARATE BUILDING, AND UNIT | | | WITH AN INDEPENDENT ENTRANCE FROM THE STREET, SHALL | | | HAVE A SEPARATE ADDRESS ASSIGNED BASED ON THE LOCATION | | | OF THE BUILDING ENTRANCE. FOR STREET ADDRESSING, | | | CONTACT CAROLINE PUELL, ADDRESSING COORDINATOR, AT | | | (561) 805 6659, OR BY EMAIL: [email protected] | | | | | | 12. ART IN PUBLIC PLACES. THIS PROJECT WILL BE SUBJECT | | | TO ART LIFE ASSESSMENT UNDER THE CITY OF WEST PALM | | | BEACH ART IN PUBLIC PLACES (AIPP) PROGRAM. FOR ADVICE | | | ON THE PROVISION OF PUBLIC ARTWORK IN LIEU OF THE AIPP | | | ASSESSMENT, CONTACT SYBILLE WELTER, ART IN PUBLIC | | | PLACES COORDINATOR, AT (561) 822-1521, OR BY EMAIL: | | | [email protected] | | | | | | ROBERT BROWN | | | BUILDING OFFICIAL | | | TEL: 561 805 6652 | | | EMAIL: [email protected] | | | |
|
|
| Review Stop |
ENG - PPRC |
ENGINEERING - PPRC |
| Rev No |
3 |
Status |
P |
Date |
09-23-2022 |
|
|
Cont ID |
|
| Sent By |
rrossano |
Date |
09-23-2022 |
Time |
|
Rev Time |
0.00 |
| Received By |
rrossano |
Date |
09-23-2024 |
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
ENG - PPRC |
ENGINEERING - PPRC |
| Rev No |
2 |
Status |
F |
Date |
05-02-2022 |
|
|
Cont ID |
|
| Sent By |
rrossano |
Date |
05-02-2022 |
Time |
|
Rev Time |
0.00 |
| Received By |
rrossano |
Date |
05-02-2022 |
Time |
|
Sent To |
|
|
| Notes |
| 2022-05-02 19:12:40 | RICK ROSSANO, SR. PROJECT COORDINATOR, ENGINEERING | | | SERVICES DEPARTMENT AT 561-494-1098 [email protected] | | | NO COMMENTS. | | | | | | MARK HURLEY, FIELD CUSTOMER SERVICE SUPERVISOR WITH | | | CITY OF WPB PUBLIC UTILITIES, REGARDING PLACEMENT OF | | | BACKFLOW DEVICES AND WATER METERS. CONTACT HIM AT | | | 561-822-2262 OR [email protected] | | | -SURVEY NOTE 1 SAYS OFFICE HAS MADE NO SEARCH OF PUBLIC | | | RECORDS. WILL A PUBLIC RECORDS SEARCH BE CONDUCTED? | | | | | | -CIVIL PLAN SHOWS FPL UTILITY EASEMENTS WHERE BUILDING | | | STRUCTURE IS PROPOSED. ARE THOSE EASEMENTS EXISTING OR | | | PROPOSED. IF EXISTING, HAS FPL GIVEN APPROVAL TO | | | BUILDING THE EASEMENTS? | | | | | | -CIVIL SECTION B-B SAYS SOD, BUT LANDSCAPING PLANS SAYS | | | GREEN ISLAND FICUS AND SWISS CHEESE PLANTS. PLEASE SHOW | | | METERS AND BACKFLOWS NEAR SOUTH SIDE OF BUILDING ON | | | PLANTING PLAN AND PROVIDE MINIMUM 18 INCHES CLEARANCE | | | BETWEEN LANDSCAPING PLANTS AND METERS, VALVES, AND | | | BACKFLOWS. BECAUSE SIZE OF UTILITIES HAS NOT BEEN | | | DETERMINED ON ENGINEERING PLANS, THE FOOTPRINT MAY | | | CHANGE AND PLANTING PLAN MAY NEED FUTURE ADJUSTMENT. | | | | | | -CANNOT ASSESS PROPOSED METERED IRRIGATION WATER | | | SERVICE RELOCATION DUE TO LIMITED DETAIL PROVIDED IN | | | CONCEPTUAL ENGINEERING PLAN. MUCH MORE DETAIL NEEDS TO | | | BE PROVIDED FOR REVIEW AT FORMAL ENGINEERING SUBMITTAL | | | | | | -WHAT IS THE CLEARANCE DISTANCE BETWEEN PROPOSED | | | BUILDING WALL ON WEST SIDE AND THE EXISTING BUILDING | | | WALL, LIGHTS, AND CONC. WALL AT EAST SIDE OF 518 | | | CLEMATIS? ASKING THIS FOR PRACTICAL MAINTENANCE | | | PURPOSES AND ALSO BECAUSE ENGINEERING PLAN SHOWS LIGHTS | | | FROM 518 CONFLICTING WITH WALL FOR 512. | | | | | | -ENGINEERING PLAN SHOWS EXISTING BE UNDER PROPOSED | | | BUILDING. VERIFY THAT IS ACCEPTABLE. ALSO SEE CBL, OHW, | | | AND TEL UTILITIES WHERE BUILDING LOCATION IS PROPOSED. | | | IF THOSE UTILITIES ARE EXISTING, PLEASE CONFIRM THAT IS | | | ACCEPTABLE. | | | | | | -WALL MOUNTING OF DCDA WOULD BE NONSTANDARD AND LIKELY | | | NOT NEEDED IF FOLLOWING STANDARD DETAILS. CLEARANCE | | | DISTANCE BETWEEN BACKFLOW AND WALL SHOULD TYPICALLY BE | | | 18 INCHES. EOR NEEDS TO PROVIDE MORE DETAIL AT FORMAL | | | ENGINEERING SUBMITTAL FOR REVIEW AND ALSO MAKE SURE | | | STILL COMPLIES WITH FIRE MARSHAL?S PRIOR 9A REVIEW | | | COMMENT. | | | | | | -SIZING OF WATER SERVICES MAY BE LIMITED DUE TO | | | EXISTING WATER MAIN DESIGN. LARGER SIZES MAY REQUIRE | | | UPSIZING WATER MAIN FROM QUADRILLE PLAZA DR. | | | | | | -THE AUTOTURN ANALYSIS DOES NOT SHOW VEHICLES ENTERING | | | OR EXISTING BUILDING. PLEASE ADD ADDITIONAL AUTOTURN | | | ANALYSIS FOR THOSE WITH AT LEAST A SMALL MOVING TRUCK. | | | | | | -ENGINEERING PLAN SHOWS EXTERIOR DOORS OPENING OUTWARD | | | WHILE ARCHITECTURAL PLANS SHOW RECESSED DOORS. PLEASE | | | UPDATE ALL PLAN SETS AND MAKE SURE THEY ALL MATCH | | | GENERAL DESIGN LAYOUT. | | | | | | |
|
|
| Review Stop |
ENG - PPRC |
ENGINEERING - PPRC |
| Rev No |
1 |
Status |
F |
Date |
03-09-2022 |
|
|
Cont ID |
|
| Sent By |
ldeloren |
Date |
03-07-2022 |
Time |
|
Rev Time |
0.00 |
| Received By |
ldeloren |
Date |
03-07-2022 |
Time |
|
Sent To |
|
|
| Notes |
| 2022-03-07 13:54:05 | Z22020019 ? 512 CLEMATIS ? 2-23-22 REVIEW | | | RICK ROSSANO, SR. PROJECT COORDINATOR, ENGINEERING | | | SERVICES DEPARTMENT AT 561-494-1098 [email protected] | | | GENERAL: | | | O PLEASE RESPOND TO ALL COMMENTS IN WRITING, AND | | | INCLUDE PROJECT NAME, ADDRESS AND PERMIT NUMBER | | | (Z-XXXXXXXX). | | | O THE CITY OF WEST PALM BEACH HAS A NUMBER OF | | | REGULATIONS AND PERMIT REQUIREMENTS WHICH DIRECTLY | | | AFFECT THE DEVELOPMENT AND INSTALLATION OF WATER AND | | | WASTEWATER UTILITIES WITHIN THE CITY. PLEASE SEE | | | DEVELOPMENT PERMIT SUBMITTAL REQUIREMENTS AT THE LINK | | | BELOW: | | | A. HTTP://WPB.ORG/CMSPAGES/GETAMAZONFILE.ASPX?PATH=~\WP | | | B_WEBSITE\MEDIA\ENGINEERING\DEVELOPMENT-APPLICATION-FUL | | | L-PACKAGE_2016.PDF&HASH=7BD4DD7EB6115181D8C5977BCC02A97 | | | B1960045731D3658206F27451722716EF | | | B. THIS AND OTHER RELATED ENGINEERING DOCUMENTS CAN BE | | | FOUND HERE: | | | HTTP://WPB.ORG/DEPARTMENTS/ENGINEERING-PUBLIC-WORKS/FOR | | | MS,-PERMITS-APPLICATIONS | | | C. ALSO SEE: CODE OF ORDINANCES, CITY OF WEST PALM | | | BEACH, FLORIDA, CODIFIED THROUGH ORD. NO. 4183-08, | | | ADOPTED SEPT. 22, 2008. (SUPPLEMENT NO. 18) | | | CHAPTER 90 UTILITIES, ARTICLE I. IN GENERAL, | | | SEC. 90-7. POLICY REGARDING EXTENSION OF WATER OR SEWER | | | SERVICE FACILITIES OF THE CITY. | | | THE WATER AND WASTEWATER SERVICE AGREEMENTS AND THE | | | CONSTRUCTION PERMITS ADDRESS RESERVATION OF CAPACITY | | | BASED ON USAGE, METER SIZE AND FEES, DESIGN STANDARDS, | | | BACKFLOW PREVENTION, FIRE SERVICE AND IRRIGATION. | | | O AS OF DECEMBER 20, 2015, THE CITY OF WEST PALM BEACH | | | CROSS-CONNECTION CONTROL MANUAL HAS BEEN REVISED, | | | STATING "ALL BACKFLOW DEVICES MUST BE LEAD-FREE". FOR | | | MORE INFORMATION, REFER TO THE LINK BELOW: | | | A. HTTP://WPB.ORG/DEPARTMENTS/PUBLIC-UTILITIES/FORMS-PU | | | BLICATIONS/BACKFLOW-CROSS-CONNECTION- CONTROL-MANUAL | | | O PLEASE SUBMIT A FORMAL AS-BUILT REQUEST FOR ALL CITY | | | OF WEST PALM BEACH-OWNED UTILITIES WITHIN THE PUBLIC | | | RIGHT OF WAY FOR THE ENTIRE EXTENT OF THE LIMITS OF | | | YOUR PROJECT. IDENTIFY TYPE OF UTILITY, LOCATION, PIPE | | | MATERIAL, AGE AND SIZE. PLEASE CONTACT JANICE TARBILL | | | IN THE WPB ENGINEERING SERVICES DEPARTMENT AT | | | [email protected] OR 561-494-1079 FOR FURTHER | | | ASSISTANCE. NOTE THAT FIELD RECORDS ARE FOR INFORMATION | | | ONLY. FIELD VERIFY UTILITY LOCATIONS USING FIELD | | | SURVEY, POT-HOLING, SOFT DIGS ETC. | | | | | | BACKFLOW ASSEMBLY AND METERS: | | | O SHOW AND LABEL ANY EXISTING OR PROPOSED WATER | | | SERVICES AND WATER METERS, ALONG WITH WHAT IS HAPPENING | | | TO THEM. | | | O SHOW EXISTING AND PROPOSED DEDICATED UTILITY | | | EASEMENTS TO ALLOW ACCESS FOR CITY PERSONNEL TO | | | PROPOSED UTILITY WATER METERS. VERIFY THAT THERE ARE NO | | | STRUCTURES WITHIN EASEMENT. | | | O PROVIDE ENLARGED VIEW ON PLANS OF PROPOSED LOCATION | | | OF WATER METER AND BACKFLOW | | | PREVENTION. | | | O BACKFLOWS SHALL BE INSTALLED ON PRIVATE PROPERTY | | | OUTSIDE OF EASEMENTS AND RIGHTS OF WAY. DOMESTIC WATER | | | METERS SHALL BE INSTALLED IMMEDIATELY ADJACENT TO | | | PROPERTY LINE. 3 INCH AND LARGER WATER METERS SHALL BE | | | INSTALLED ABOVE-GROUND ONLY. | | | O CALLOUT DOMESTIC BACKFLOW PREVENTER AS RPPA (MAKE | | | NOTE USC APPROVED) AND FIRE BACKFLOW PREVENTER AS DCDA. | | | | | | WATER/WASTEWATER PLAN: | | | O PROVIDE VERTICAL DATUM AND DATUM CONVERSION | | | INFORMATION (NAVD 1988 AND NGVD 1929). | | | O SHOW PROJECT ADDRESS ON ALL PLAN SHEETS. | | | O PROVIDE LEGEND ON ALL PLAN SHEETS TO INCLUDE | | | STREETLIGHT, SIGN POSTS, TRANSFORMER BOXES ETC. | | | O PLANS SHALL SHOW EXISTING AND PROPOSED LOCATIONS AND | | | DIMENSIONS OF ALL WATER, STORMWATER, AND SANITARY AND | | | SEWER LINES AND CLEANOUTS, INCLUDING STUBS TO EACH | | | PROPERTY LINE FOR WATER AND SANITARY SEWERS, THE MAKE | | | AND MODEL OF ALL VALVES, POTABLE AND IRRIGATION METERS, | | | BACKFLOWS, FIRE HYDRANTS AND FDCS, AND OTHER DEVICES TO | | | BE INSTALLED ON THE SYSTEM, CATCH BASINS, CULVERTS, | | | DITCHES INCLUDING GRADES, PIPES SIZES, MATERIALS, | | | ELEVATIONS, ASSUMPTIONS, CALCULATIONS, INVERT | | | ELEVATIONS FOR ALL INLETS AND MANHOLES AND PROFILES OF | | | SANITARY SEWER LINES. | | | O GATE VALVE BOXES SHALL NOT BE INSTALLED IN CURB OR | | | SIDEWALK. ALL AVAILABLE ELEVATION SHALL BE SHOWN ON THE | | | PROFILE VIEW. | | | O DIRECTION OF FLOW SHALL BE SHOWN ON PLAN VIEW ON PLAN | | | VIEW FOR ALL SANITARY AND STORM SEWERS. | | | O SHOW SLOPE % ON ALL SANITARY LINES AND CALL OUT | | | MATERIAL. | | | O PLAN VIEW SHALL SHOW ALL EXISTING AND PROPOSED | | | UNDERGROUND UTILITY LAYOUT, INCLUDING FIBER OPTIC, | | | ELECTRIC, GAS, AND CABLEVISION & TELECOMMUNICATION | | | FACILITIES LOCATED ON THE RIGHT-OF-WAY. | | | O PROVIDE PROFILE AND CLEARANCES BETWEEN WATER, SEWER | | | AND STORM LINES PER CITY OF WEST PALM BEACH STANDARD | | | DETAIL GN-2 SERIES, AT ALL UTILITY CROSSINGS. | | | O SUBMIT COMPLETED LOS ANALYSIS SUMMARY TABLE DIRECTLY | | | TO ENGINEERING (SHEET 33 OF CITY OF WPB DEVELOPMENT | | | APPLICATION). PROVIDE CALCULATIONS ON PLANS OF EXISTING | | | AND PROPOSED DEMANDS FOR WATER & SEWER (AVERAGE, | | | MAXIMUM AND PEAK) AND FIRE FLOW DEMANDS. CALCULATIONS | | | SHALL BE PER FAC 64E-6 FOR SEWER AND PER FAC 64-E.008 | | | FOR WATER. | | | O PROVIDE FIRE FLOW TEST DATA. | | | O PROVIDE CCTV VIDEO OF EXISTING SANITARY SEWER AND | | | STORMWATER INFRASTRUCTURE ALONG ENTIRE PROJECT | | | FRONTAGE. | | | O CUT AND CAP UTILITIES NOT IN USE AND REMOVE ANY | | | ABANDONED UTILITY LINES LARGER THAN 2 INCHES FROM CITY | | | ROW. | | | O WHEN PROPOSED, WATER MAINS IN CITY RIGHT OF WAY SHALL | | | BE MADE OF DUCTILE IRON PIPE (NOT PVC) AND SPECIFY | | | PROPOSED LENGTH IN FEET. | | | O CHECK TO SEE IF FDEP FORMS FOR PROPOSED SANITARY | | | SEWER ARE REQUIRED. | | | O PROVIDE CLEANOUTS FOR PROPOSED SANITARY LINE ONSITE | | | JUST INSIDE PROPERTY LINE, AT JOINTS AND EVERY 75 FEET. | | | O ADD NOTE TO PLANS SPECIFYING CITY?S DOWNSTREAM LIFT | | | STATION NUMBER. | | | O PROVIDE ONSITE CLEANOUTS NEAR PROPERTY LINE FOR | | | PROPOSED SANITARY LATERALS. | | | O LABEL WATER LINES AS PRIVATE WHERE APPLICABLE. | | | O PLEASE SHOW AND LABEL EXISTING AND PROPOSED GREASE | | | TRAPS (IF ANY). | | | O PER CITY STANDARDS MAINTAIN MINIMUM DISTANCE BETWEEN | | | OUTSIDE DIAMETER OF CITY PIPE AND ROOT BARRIER. | | | | | | FORMAL ENGINEERING REVIEW: | | | O FOR FORMAL ENGINEERING SUBMITTAL, SFWMD ERP AND NPDES | | | NOI REQUIREMENTS WILL BE ENFORCED. | | | - AN NOI IS REQUIRED FOR PROJECTS THAT: | | | - 1) DISTURB ONE OF MORE ACRES OF LAND OR DISTURB LESS | | | THAN ON ACRE OF LAND BUT ARE PART OF A COMMON PLAN OF | | | DEVELOPMENT OR SALE; | | | - 2) DISCHARGE STORMWATER TO SURFACE WATERS OF THE | | | STATE OR TO SURFACE WATERS OF THE STATE THROUGH A | | | MUNICIPAL SEPARATE STORM SEWER SYSTEM (MS4). | | | - THE SFWMD ERP CAN BE OBTAINED THROUGH A 10-2 SELF | | | CERTIFICATION THROUGH FDEP OR AN ERP APPLICATION | | | THROUGH SFWMD. EITHER WAY, THE DEVELOPER/ENGINEER SHALL | | | SUBMIT A COPY OF THE ERP PERMIT OR FDEP ACKNOWLEDGEMENT | | | OF THE 10-2 CERTIFICATION. | | | O FOR FORMAL ENGINEERING SUBMITTAL, PLEASE PROVIDE | | | EASEMENT FOR PLACEMENT OF PROPOSED WATER METERS. | | | O FOR FORMAL ENGINEERING SUBMITTAL, PROVIDE PROFILES OF | | | WATER AND SEWER AND SHOW ANY CROSSINGS/CONFLICTS. | | | O FOR FORMAL ENGINEERING SUBMITTAL, WHEN SUBMITTING | | | APPROVED MATERIALS LIST, PLEASE PROVIDE MATERIAL/CUT | | | SHEETS FOR ALL PROPOSED BACKFLOW DEVICES SHOWING | | | SPECIFIC MODEL NUMBER AND SPECIFYING USC APPROVED | | | LEAD-FREE DESIGN. | | | O FOR FORMAL ENGINEERING SUBMITTAL, IF SANITARY LINES | | | ARE PROPOSED IN ROW PLEASE SHOW ADJACENT SANITARY | | | LATERAL LOCATIONS AND SHOW ADDRESSES OF ADJACENT | | | PARCELS. | | | O FOR FORMAL ENGINEERING SUBMITTAL, IF WATER LINES ARE | | | BEING REPLACED IN ROW, SHOW ADJACENT PARCEL ADDRESSES. | | | O FOR FORMAL ENGINEERING SUBMITTAL, ADD NOTE TO PROVIDE | | | 50 FT. PAVEMENT RESTORATION TRANSITION ON EACH SIDE OF | | | PROPOSED TRENCH IN CITY MAINTAINED ROADWAY AREAS PER | | | CITY OF WPB STANDARD DETAIL GC-8. | | | O FOR FORMAL ENGINEERING SUBMITTAL, PLEASE PROVIDE | | | CALCULATIONS OF PERVIOUS AND IMPERVIOUS AREAS FOR | | | PROPOSED IMPROVED AREAS. | | | | | | MARK HURLEY, FIELD CUSTOMER SERVICE SUPERVISOR WITH | | | CITY OF WPB PUBLIC UTILITIES, REGARDING PLACEMENT OF | | | BACKFLOW DEVICES AND WATER METERS. CONTACT HIM AT | | | 561-822-2262 OR [email protected] | | | O -UTILITY CONCURRENCY DOCUMENT STATES 48 MICROUNITS, | | | BUT OTHER DOCUMENTS SAY 89. UPDATE SO DOCUMENTS MATCH | | | NUMBER OF UNITS. DO THE SAME FOR SQ FT OF RETAIL. | | | O | | | O -SURVEY NOTE 1 SAYS OFFICE HAS MADE NO SEARCH OF | | | PUBLIC RECORDS. WILL A PUBLIC RECORDS SEARCH BE | | | CONDUCTED? | | | O | | | O -VERIFY DCDA LOCATION IS NFPA COMPLIANT. | | | O | | | O -SHOW GATE VALVE FOR FIRELINE. | | | O | | | O -IF FDC IS NEEDED OR REQUIRED, THEN SHOW IT ON | | | ENGINEERING PLAN. | | | O | | | O -THERE ARE OVERLAPPING DOORS ON THE EAST SIDE OF | | | BUILDING ON ENGINEERING PLAN. | | | O | | | O -DRIVEWAY APRON FROM ALLEY TO QUADRILLE PLAZA DR. MAY | | | BE ALTERED DURING CLEMATIS ALLEY IMPROVEMENT PROJECT. | | | O | | | O -A1 SHOWS ROLL DOWN GATES AT PARKING ENTRANCES AT | | | SOUTH SIDE OF BUILDING. WHEN WILL THEY BE ROLLED DOWN? | | | O | | | O -WILL THERE BE INTERIOR WALLS DIVIDING THE RETAIL | | | AREAS? | | | O | | | O -THERE ARE DIFFERENCES BETWEEN THE BUILDING LAYOUT OF | | | THE ENGINEERING AND ARCHITECTURAL PLANS, SUCH AS DOOR | | | PLACEMENT. PLANS SHOULD BE SIMILAR. | | | O | | | O -CANNOT FIND PARKING SPOTS FOR LARGE TRUCKS. HOW WILL | | | DELIVERIES AND TENANT MOVE INS WORK? | | | O | | | O -CANNOT USE EXISTING 1 INCH METERED WATER SERVICE AND | | | BACKFLOW ASSEMBLY AS SHOWN ON WATER PLAN. | | | O | | | O -GENERALLY DO NOT SEE 1 INCH WATER SERVICES FOR | | | SIMILAR PROPERTIES. IF A 3 INCH OR LARGER WATER METER | | | IS NEEDED, THEN IT NEEDS TO BE INSTALLED ABOVE-GROUND | | | AND SHOULD NOT BE IN PEDESTRIAN TRAFFIC. THEY HAVE | | | LARGER FOOTPRINTS, SO RECOMMEND PLANNING AHEAD. | | | O | | | O -DCDA FOOTPRINT IS LIKELY LARGER THAN SHOWN ON THE | | | WATER PLAN. | | | O | | | O -PAVEMENT RESTORATION BOUNDARIES APPEAR SMALLER THAN | | | REQUIRED. | | | O | | | O -ENGINEERING PLAN HAS AN EXISTING CLEANOUT LABELED, | | | BUT DO NOT SEE SEWER LATERAL SHOWN. IS PLAN DRAWN AND | | | LABELED CORRECTLY? | | | O | | | O -SHOW ALL EXISTING UTILITIES AS SOME MISSING. FOR | | | EXAMPLE, THE METERED WATER SERVICE AT SOUTHEAST AREA OF | | | PROPERTY IS NOT SHOWN. ONCE EXISTING UTILITIES ARE | | | SHOWN, ENSURE NO CONFLICTS WITH PROPOSED CONSTRUCTION. | | | O | | | O -THE WATER SERVICE NEAR SOUTHEAST CORNER OF PROPERTY | | | IS UNDER CITY WPB PARKS DEPARTMENT ACCOUNT. THEY WOULD | | | HAVE TO AGREE WITH ANY CHANGES TO THE ACCOUNT OR | | | BACKFLOW ASSEMBLY. SOUTHEAST CORNER OF BUILDING | | | CONFLICTS WITH BACKFLOW ASSEMBLY. | | | O | | | O -ENGINEERING PLAN DOES NOT HAVE DEMOLITION SHEET, | | | COVER SHEET, STANDARD DETAILS SHEET, OR SWPPP SHEET. | | | O | | | O -SHOW AND LABEL DOMESTIC BACKFLOW ASSEMBLY ON WATER | | | PLAN. CALLOUT RP TYPE. | | | O | | | O -WILL R TANK STORAGE CHAMBER BE TIED INTO FIRE | | | SYSTEM? | | | O | | | O -ARE ALL UTILITY EASEMENTS SHOWN ON THE ENGINEERING | | | PLANS? | | | O | | | O -WHAT IS THE CLEARANCE DISTANCE BETWEEN PROPOSED | | | BUILDING WALL ON WEST SIDE AND THE EXISTING BUILDING | | | WALL, LIGHTS, AND CONC. WALL AT EAST SIDE OF 518 | | | CLEMATIS? | | | O | | | O -PLANS FOR CLEMATIS ALLEYWAY PROJECT SHOW UNDERGROUND | | | ELECTRIC AND TELEPHONE LINES RUNNING UNDER 512 CLEMATIS | | | PROPERTY. VERIFY IF THAT IS CORRECT. | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
05-04-2022 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
05-04-2022 |
Time |
10:41 |
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
05-04-2022 |
Time |
10:41 |
Sent To |
|
|
| Notes |
| 2022-05-04 10:43:54 | 2ND REVIEW RESPONSE | | | | | | AFTER A REVIEW OF THE PPRC RESPONSE PACKET FOR THIS | | | PROJECT ON MAY 4, 2022, THE PREVIOUSLY SUBMITTED FIRE | | | PREVENTION BUREAU COMMENTS APPEAR TO HAVE BEEN | | | ADDRESSED. | | | | | | HOWEVER, THE BUREAU'S APPROVAL OF THIS SUBMITTED | | | PROJECT DOES NOT CONSTITUTE ITS FINAL REVIEW OR | | | APPROVAL. | | | | | | THE BUREAU SHALL REVIEW ALL SUBMITTED BUILDING PLANS AT | | | THE APPROPRIATE TIME AND IN ACCORDANCE WITH THE | | | REQUIREMENTS OF ALL APPLICABLE CODES AND STANDARDS. | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | WEST PALM BEACH FIRE DEPARTMENT | | | 561-804-4709 | | | [email protected] | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
02-28-2022 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
02-28-2022 |
Time |
15:14 |
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
02-28-2022 |
Time |
15:02 |
Sent To |
|
|
| Notes |
| 2022-02-28 15:13:32 | THE FOLLOWING COMMENTS WERE SUBMITTED BY PETER LEDUC, | | | FIRE MARSHAL, BUREAU OF FIRE PREVENTION, WEST PALM | | | BEACH FIRE DEPARTMENT. | | | | | | THIS REVIEW CAN ONLY BE CONSIDERED PRELIMINARY AS THE | | | DRAWINGS THAT WERE REVIEWED WERE NOT COMPLETE. | | | ADDITIONAL COMMENTS CAN BE EXPECTED WHEN FULL DRAWINGS | | | ARE SUBMITTED FOR PERMIT. | | | | | | THE FIRE PREVENTION BUREAU HAS NO OBJECTIONS TO THE | | | PROPOSED PROJECT. THE FOLLOWING COMMENTS ARE INTENDED | | | TO PROVIDE GUIDANCE FOR BUILDING PLAN SUBMITTAL. | | | | | | 1. CONSTRUCTION, DEMOLITION, AND RENOVATION TO COMPLY | | | WITH NFPA 241. EXTRA ATTENTION SHALL BE GIVEN TO THE | | | PERMITTING AND LOCATION OF CONSTRUCTION TRAILERS. A | | | PERMIT IS REQUIRED FOR ANY CONSTRUCTION TRAILER RELATED | | | TO THIS PROJECT. SEPARATION DISTANCES FROM MAIN | | | STRUCTURES AS WELL AS OTHER TRAILERS SHALL BE CLOSELY | | | MONITORED FOR THE REQUIREMENTS OF FIRE SPRINKLER | | | PROTECTION. | | | | | | 2. SITE ACCESS AND EXIT POINTS ARE TO BE CLEARLY | | | IDENTIFIED AND MAINTAINED FOR EMERGENCY VEHICLES DURING | | | ALL CONSTRUCTION ACTIVITIES. | | | | | | 3. THE BUILDING ADDRESS SHALL BE CLEARLY VISIBLE FROM | | | ALL ACCESS ROADWAYS, INCLUDING DURING CONSTRUCTION. | | | ADDRESS NUMBERS SHALL CONTRAST WITH THEIR BACKGROUND | | | AND SHALL NOT BE LESS THAN SIX (6) INCHES IN HEIGHT | | | WITH A ONE (1) INCH STROKE FOR ALL BUILDINGS. | | | | | | 4. DURING CONSTRUCTION, TRASH AND DEBRIS IS TO BE | | | REMOVED FROM THE SITE DAILY OR MORE OFTEN TO REDUCE THE | | | ACCUMULATION OF POTENTIAL LIFE AND FIRE SAFETY HAZARDS. | | | | | | 5. THE CONSTRUCTION OF THE BUILDING(S) SHALL COMPLY | | | WITH THE 7TH EDITION OF THE FLORIDA FIRE PREVENTION | | | CODE, INCLUDING NFPA 1 & 101, AND ALL ASSOCIATED FIRE | | | CODES. | | | | | | 6. FOR PLAN REVIEW SUBMITTAL, PLEASE INCLUDE THE | | | OCCUPANCY TYPE PER THE FLORIDA FIRE PREVENTION CODE. | | | | | | 7. FOR PLAN REVIEW SUBMITTAL, PLEASE ENSURE THAT A FIRE | | | LOAD CALCULATION IS INCLUDED, AND THAT ADEQUATE WATER | | | SUPPLY IS EXISTING OR WILL BE PROVIDED. | | | | | | 8. ALL EXISTING AND NEW FIRE HYDRANTS PLANNED FOR THIS | | | DEVELOPMENT SHALL BE CLEARLY INDICATED AND IDENTIFIED | | | ON THE PLAN AND CLOSELY COORDINATED WITH THE BUREAU OF | | | FIRE PREVENTION. | | | | | | AN EXISTING OR PROPOSED FIRE HYDRANT AND FDC WERE NOT | | | IDENTIFIED ON THE CIVIL PLAN AND SHALL BE WITHIN 100' | | | OF EACH OTHER AND CLOSELY COORDINATED WITH THE BUREAU | | | OF FIRE PREVENTION. | | | | | | 9. PROVIDE FOR A FIRE SPRINKLER AND/OR FIRE ALARM PER | | | THE APPLICABLE OCCUPANCY CODE. FOR ANY LIFE SAFETY | | | ENGINEERED SYSTEM, I.E FIRE SPRINKLER AND FIRE ALARM, | | | ENSURE THEY COMPLY WITH THE REQUIREMENTS OF F.A.C. 61G | | | AND SUBMITTED WITH THE MASTER PERMIT. | | | | | | 9A. THE LOCATION OF ANY APPLICABLE DDCV AND FIRE LINE | | | LOCATIONS SHALL MEET AND BE INSTALLED PER THE | | | REQUIREMENTS OF NFPA 24 AND SHALL BE COORDINATED WITH | | | THE OFFICE OF FIRE MARSHAL, THE CITY'S ENGINEERS | | | OFFICE, THE LANDSCAPE PLANNER, AND THE CITY'S PLANNING | | | AND ZONING OFFICE. | | | | | | THERE WAS NO PROPOSED LOCATION OF THE THE FIRE DDCV, | | | | | | CONSIDERATION SHOULD BE GIVEN TO BEING VULNERABLE TO | | | VEHICLE TRAFFIC, FALLING DEBRIS IN A FIRE EVENT AND | | | EXTERIOR COVER PROTECTION. | | | | | | 10. COMPLETE LIFE SAFETY PLANS FOR THE OCCUPANCY SHALL | | | BE PROVIDED THAT ILLUSTRATE OCCUPANT LOADS, TRAVEL | | | DISTANCES, EXIT SEPARATION DISTANCES, COMMON PATHS OF | | | TRAVEL, DEAD-END CORRIDORS, EXIT SIGNS, EMERGENCY | | | LIGHTING, EXITS LEADING TO A PUBLIC WAY, FIRE | | | EXTINGUISHER LOCATIONS, AND ALL FIRE SAFETY FEATURES | | | AND EQUIPMENT. | | | | | | 11. IT IS HIGHLY RECOMMENDED (REQUIRED WITH FIRE | | | SPRINKLER SYSTEM) THAT A KNOX BOX WITH KEYS FOR ENTRY | | | DOOR LOCKS BE PROVIDED FOR 24 HOUR EMERGENCY ACCESS. | | | | | | 12. ALL NEW ELEVATORS SHALL CONFORM TO THE FIRE | | | FIGHTER?S EMERGENCY OPERATIONS REQUIREMENTS OF ASME | | | A17.1/CSA B44, SAFETY CODE FOR ELEVATORS. | | | ANY BUILDING THAT IS MORE THAN THREE STORIES HIGH OR IN | | | WHICH THE VERTICAL DISTANCE BETWEEN THE BOTTOM TERMINAL | | | LANDING AND THE TOP TERMINAL LANDING EXCEEDS 25 FEET | | | MUST BE CONSTRUCTED TO CONTAIN AT LEAST ONE PASSENGER | | | ELEVATOR THAT IS OPERATIONAL AND WILL ACCOMMODATE AN | | | AMBULANCE STRETCHER 76 INCHES LONG AND 24 INCHES WIDE | | | IN THE HORIZONTAL POSITION. | | | | | | 13. TWO-WAY RADIO COMMUNICATIONS ENHANCEMENT SYSTEMS. | | | NFPA 1, CHAPTER 11, BUILDING SERVICES; 11.10 TWO-WAY | | | RADIO ENHANCEMENT SERVICES. | | | 11.10.1 IN ALL NEW AND EXISTING BUILDINGS, MINIMUM | | | RADIO SIGNAL STRENGTH FOR FIRE DEPARTMENT | | | COMMUNICATIONS SHALL BE MAINTAINED AT A LEVEL | | | DETERMINED BY THE AHJ. | | | | | | CONTACT WILL NEED TO BE MADE TO MARK FILLA, PALM BEACH | | | COUNTY PUBLIC SAFETY RADIO SYSTEMS MANAGER, | | | [email protected], 561-233-0837; AS OUR RADIOS OPERATE | | | ON THEIR SYSTEM FOR DETAILED RADIO FREQUENCY AND | | | INSTALLATION INSTRUCTIONS. | | | | | | 14. THE BUREAU'S APPROVAL OF THIS SUBMITTED PROJECT | | | DOES NOT CONSTITUTE ITS FINAL REVIEW OR APPROVAL. | | | | | | 15. THE BUREAU SHALL REVIEW ALL SUBMITTED BUILDING | | | PLANS AT THE APPROPRIATE TIME AND IN ACCORDANCE WITH | | | THE REQUIREMENTS OF ALL APPLICABLE CODES AND STANDARDS. | | | | | | | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
1 |
Status |
P |
Date |
03-09-2022 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
03-09-2022 |
Time |
08:25 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
03-09-2022 |
Time |
08:24 |
Sent To |
|
|
| Notes |
| 2022-03-09 08:28:58 | REQUIRES HPB REVIEW/APPROVAL. | | | | | | PLEASE ADDRESS: | | | -INCORPORTAION OF ORIGINAL BADCOCK TERRACOTTA PIECE | | | -ADD TREATMENT TO BLANK WALL THAT IS VISIBLE FROM | | | CLEMATIS ON PATIO AREA AT NE CORNER BEHIND ARCADE | | | - ADD TREATMENT/LANDSCAPE TO BLANK COLUMNAL SPACE ON | | | EAST ELEVATION |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
3 |
Status |
P |
Date |
09-22-2022 |
|
|
Cont ID |
|
| Sent By |
rcaranci |
Date |
09-22-2022 |
Time |
15:58 |
Rev Time |
0.00 |
| Received By |
rcaranci |
Date |
09-22-2022 |
Time |
15:58 |
Sent To |
|
|
| Notes |
| 2022-09-22 15:58:56 | FROM: RAY CARANCI, SENIOR LANDSCAPE PLANNER | | | 561-822-1462 | | | PROJECT: 512 CLEMATIS Z22020019 | | | SEPTEMBER 20, 2022 | | | I HAVE REVIEWED THE ABOVE REFERENCED PETITION, AND | | | PROVIDE THE FOLLOWING COMMENTS: | | | | | | | | | 1. MAKE THE FOLLOWING CORRECTIONS TO THE TREE | | | DISPOSITION PLAN: | | | ??? SATISFIED. ARECA PALMS DO NOT REQUIRE MITIGATION. | | | REVISE CHART. | | | ??? SATISFIED. INDICATE HOW THE 200 SQ FT OF MITIGATION | | | DUE WILL BE PROVIDED. | | | THE PLANT LIST PROVIDES ENOUGH MITIGATION TO COVER THE | | | 200 SQ FT OF MITIGATION DUE. | | | 2. SATISFIED. PER SECTION 94-113, THE STREETSCAPE ON | | | QUADRILLE PLAZA DRIVE IS TO BE MODIFIED TO PROVIDE THE | | | 4 FOOT WIDE PLANTING STRIP ALONG THE CURB. THE BASE | | | PLANTINGS AT THE BUILDING WILL BE NARROWED TO PROVIDE | | | THE REQUIRED SIDEWALK WIDTH. | | | CURBSIDE PLANTING STRIP NEEDS TO BE ALONG THE ENTIRE | | | STREETSCAPE. SOUTH PORTION IS LACKING ON SHEET L-2.0 AS | | | SHOWN ON SHEET A-1. | | | | | | 3. CONDITIONALLY SATISFIED. IRRIGATION FOR THE ADJACENT | | | QUADRILLE PLAZA DR STREETSCAPE IS TO BE PROVIDED FROM | | | THE SITE. EXISTING IRRIGATION IS TO BE MODIFIED TO | | | REMOVE THIS AREA FROM THE SYSTEM. THE APPLICANT WILL BE | | | RESPONSIBLE FOR RELOCATING THE WATER METER AND BACKFLOW | | | FROM THE SITE TO A LOCATION SPECIFIED BY THE CITY TO | | | SERVICE THE REMAINING AREAS ON THE EAST SIDE OF THE | | | ROAD. FPL SITE TO THE SOUTH WILL BE INSTALLING | | | IRRIGATION FOR THE STREET TREES ADJACENT TO THEIR | | | PROPERTY. | | | | | | 4. SATISFIED. THERE IS NOT SUFFICIENT SPACE FOR THE | | | LIVE OAK TREES PROPOSED FOR THE ALLEY. REVISE TO | | | PROVIDE APPROPRIATE PALMS OR SMALL TREES TO ELIMINATE | | | CONFLICT WITH TRAFFIC AND UTILITIES. | | | OAK TREES REMOVED, BUT NOTHING SHOWN TO REPLACE. | | | | | | 5. CONDITIONALLY SATISFIED. PROVIDE A DIAGRAM OF THE | | | PROVIDED 25% PRIVATE OPEN SPACE AREAS FOR CWD-CD. | | | IDENTIFY THE TYPE OF OPEN SPACE AS ALLOWED BY TABLE | | | IV-7 AND DEFINITIONS IN SECTION 94-109. SHOW HOW THE | | | STANDARDS FOR THE TYPES OF OPEN SPACE ARE MET INCLUDING | | | VEGETATED AREAS AND TREE CANOPY SQUARE FOOTAGE BASED ON | | | TABLE IV-8. | | | DIAGRAM NEEDS MORE DETAIL. IF THE PRIVATE OPEN SPACE | | | TYPE IS ???TERRACE??? LABEL IT, THEN SHOW THE AREA AND | | | HOW ALL REQUIREMENTS ARE MET. | | | | | | | | | 6. SATISFIED. SHOW THE LOCATIONS OF ALL UTILITIES ON | | | THE LANDSCAPE PLAN AND RESOLVE ANY CONFLICTS. | | | THERE APPEAR TO BE CONFLICTS IN LOCATIONS BETWEEN | | | EXISTING STREET TREES WITH THE PROPOSED UTILITIES. | | | THE UTILITIES ARE NOT SHOWN ON THE LANDSCAPE PLAN. | | | THE DRAINAGE LINE CONNECTING TO THE INLET ON CLEMATIS | | | IS TOO CLOSE TO THE EXISTING TREE ROOT SYSTEM. | | | | | | | | | | | | 7. SATISFIED. THE FLORIDA FRIENDLY DESIGN OPTIONS CHART | | | NEEDS TO BE UPDATED TO CURRENT CODE REQUIREMENTS. | | | SEVERAL ITEMS NEED THE WORDING ADJUSTED TO MATCH | | | CURRENT CODE. | | | THERE ARE STILL ERRORS IN THE CHART. | | | | | | 8. SATISFIED. REVISE RENDERING TO ACCURATELY SHOW THE | | | LOCATION AND SIZE OF THE EXISTING AND PROPOSED STREET | | | TREES AND LANDSCAPING. | | | | | | SOME OF THE RENDERINGS ARE STILL NOT ACCURATE WITH | | | LOCATIONS AND SIZE OF EXISTING TREES. | | | ADDITIONAL COMMENTS 6/7/22: | | | 9. SATISFIED. POLYALTHEA LONGIFOLIA AND CAESALPINIA | | | GRANADILLO ARE NOT FLORIDA NATIVE PLANT SPECIES. | | | CORRECT ON PLANT LIST. | | | CONDITIONS OF APPROVAL | | | 1. PRIOR TO THE REMOVAL OR RELOCATION OF ANY TREES ON | | | THE PROPERTY, A TREE ALTERATION PERMIT SHALL BE | | | SUBMITTED, REVIEWED AND APPROVED BY THE DEVELOPMENT | | | SERVICES DEPARTMENT, PLANNING DIVISION. | | | | | | 2. THE APPLICANT, SUCCESSORS AND ASSIGNS SHALL BE | | | RESPONSIBLE FOR THE PERMITTING AND INSTALLATION OF THE | | | RIGHT OF WAY LANDSCAPING AND IRRIGATION APPROVED WITH | | | THIS PETITION. | | | | | | 3. THE APPLICANT SHALL PROVIDE IRRIGATION FOR THE | | | ADJACENT QUADRILLE PLAZA DR STREETSCAPE FROM THE SITE. | | | EXISTING IRRIGATION IS TO BE MODIFIED TO REMOVE THIS | | | AREA FROM THE SYSTEM. THE APPLICANT WILL BE RESPONSIBLE | | | FOR RELOCATING THE WATER METER AND BACKFLOW FROM THE | | | SITE TO A LOCATION SPECIFIED BY THE CITY TO SERVICE THE | | | REMAINING AREAS ON THE EAST SIDE OF THE ROAD. WATERING | | | FOR THE STREET TREES SHALL BE MAINTAINED AT ALL TIMES | | | DURING CONSTRUCTION. | | | | | | 4. THE APPLICANT, SUCCESSORS AND ASSIGNS SHALL BE | | | RESPONSIBLE FOR THE MAINTENANCE OF THE STREETSCAPE | | | LANDSCAPING AND IRRIGATION. THIS WILL BE THROUGH A | | | SEPARATE MAINTENANCE AGREEMENT WITH THE CITY. | | | | | | 5. PRIOR TO SITE PLAN APPROVAL, THE SHEET SHEET L3.0 | | | RENDERING SHALL BE REVISED TO MATCH THE LANDSCAPE PLAN. | | | | | | | | | 6. PRIOR TO SITE PLAN APPROVAL, SHEETS L2.1 AND L2.2 | | | SHALL BE REVISED TO SHOW THE SQUARE FOOTAGE AND | | | PERCENTAGE OF THE DESIGNATED TERRACE AREA THAT IS | | | VEGETATED AREA TO MEET THE 20% VEGETATED AREA. THE | | | TOTAL PRIVATE OPEN SPACE SQUARE FOOTAGE REQUIRED AND | | | THE TOTAL PROVIDED SHALL BE SHOWN ON THE PLAN. | | | |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
2 |
Status |
F |
Date |
06-07-2022 |
|
|
Cont ID |
|
| Sent By |
rcaranci |
Date |
06-07-2022 |
Time |
11:49 |
Rev Time |
0.00 |
| Received By |
rcaranci |
Date |
06-07-2022 |
Time |
11:49 |
Sent To |
|
|
| Notes |
| 2022-06-07 11:50:37 | FROM: RAY CARANCI, SENIOR LANDSCAPE PLANNER | | | 561-822-1462 | | | PROJECT: 512 CLEMATIS Z22020019 | | | JUNE 7, 2022 | | | I HAVE REVIEWED THE ABOVE REFERENCED PETITION, AND | | | PROVIDE THE FOLLOWING COMMENTS: | | | | | | | | | 1. MAKE THE FOLLOWING CORRECTIONS TO THE TREE | | | DISPOSITION PLAN: | | | ? SATISFIED. ARECA PALMS DO NOT REQUIRE MITIGATION. | | | REVISE CHART. | | | ? SATISFIED. INDICATE HOW THE 200 SQ FT OF MITIGATION | | | DUE WILL BE PROVIDED. | | | THE PLANT LIST PROVIDES ENOUGH MITIGATION TO COVER THE | | | 200 SQ FT OF MITIGATION DUE. | | | 2. PARTIALLY SATISFIED. PER SECTION 94-113, THE | | | STREETSCAPE ON QUADRILLE PLAZA DRIVE IS TO BE MODIFIED | | | TO PROVIDE THE 4 FOOT WIDE PLANTING STRIP ALONG THE | | | CURB. THE BASE PLANTINGS AT THE BUILDING WILL BE | | | NARROWED TO PROVIDE THE REQUIRED SIDEWALK WIDTH. | | | CURBSIDE PLANTING STRIP NEEDS TO BE ALONG THE ENTIRE | | | STREETSCAPE. SOUTH PORTION IS LACKING ON SHEET L-2.0 AS | | | SHOWN ON SHEET A-1. | | | | | | 3. SATISFIED. IRRIGATION FOR THE ADJACENT QUADRILLE | | | PLAZA DR STREETSCAPE IS TO BE PROVIDED FROM THE SITE. | | | EXISTING IRRIGATION IS TO BE MODIFIED TO REMOVE THIS | | | AREA FROM THE SYSTEM. THE APPLICANT WILL BE RESPONSIBLE | | | FOR RELOCATING THE WATER METER AND BACKFLOW FROM THE | | | SITE TO A LOCATION SPECIFIED BY THE CITY TO SERVICE THE | | | REMAINING AREAS ON THE EAST SIDE OF THE ROAD. FPL SITE | | | TO THE SOUTH WILL BE INSTALLING IRRIGATION FOR THE | | | STREET TREES ADJACENT TO THEIR PROPERTY. | | | | | | 4. PARTIALLY SATISFIED. THERE IS NOT SUFFICIENT SPACE | | | FOR THE LIVE OAK TREES PROPOSED FOR THE ALLEY. REVISE | | | TO PROVIDE APPROPRIATE PALMS OR SMALL TREES TO | | | ELIMINATE CONFLICT WITH TRAFFIC AND UTILITIES. | | | OAK TREES REMOVED, BUT NOTHING SHOWN TO REPLACE. | | | | | | 5. PARTIALLY SATISFIED. PROVIDE A DIAGRAM OF THE | | | PROVIDED 25% PRIVATE OPEN SPACE AREAS FOR CWD-CD. | | | IDENTIFY THE TYPE OF OPEN SPACE AS ALLOWED BY TABLE | | | IV-7 AND DEFINITIONS IN SECTION 94-109. SHOW HOW THE | | | STANDARDS FOR THE TYPES OF OPEN SPACE ARE MET INCLUDING | | | VEGETATED AREAS AND TREE CANOPY SQUARE FOOTAGE BASED ON | | | TABLE IV-8. | | | DIAGRAM NEEDS MORE DETAIL. IF THE PRIVATE OPEN SPACE | | | TYPE IS ?TERRACE? LABEL IT, THEN SHOW THE AREA AND HOW | | | ALL REQUIREMENTS ARE MET. | | | | | | | | | 6. NOT SATISFIED. SHOW THE LOCATIONS OF ALL UTILITIES | | | ON THE LANDSCAPE PLAN AND RESOLVE ANY CONFLICTS. | | | THERE APPEAR TO BE CONFLICTS IN LOCATIONS BETWEEN | | | EXISTING STREET TREES WITH THE PROPOSED UTILITIES. | | | THE UTILITIES ARE NOT SHOWN ON THE LANDSCAPE PLAN. | | | THE DRAINAGE LINE CONNECTING TO THE INLET ON CLEMATIS | | | IS TOO CLOSE TO THE EXISTING TREE ROOT SYSTEM. | | | | | | | | | | | | 7. NOT SATISFIED. THE FLORIDA FRIENDLY DESIGN OPTIONS | | | CHART NEEDS TO BE UPDATED TO CURRENT CODE REQUIREMENTS. | | | SEVERAL ITEMS NEED THE WORDING ADJUSTED TO MATCH | | | CURRENT CODE. | | | THERE ARE STILL ERRORS IN THE CHART. | | | | | | 8. PARTIALLY SATISFIED. REVISE RENDERING TO ACCURATELY | | | SHOW THE LOCATION AND SIZE OF THE EXISTING AND PROPOSED | | | STREET TREES AND LANDSCAPING. | | | | | | SOME OF THE RENDERINGS ARE STILL NOT ACCURATE WITH | | | LOCATIONS AND SIZE OF EXISTING TREES. | | | | | | ADDITIONAL COMMENTS 6/7/22: | | | | | | 9. POLYALTHEA LONGIFOLIA AND CAESALPINIA GRANADILLO ARE | | | NOT FLORIDA NATIVE PLANT SPECIES. CORRECT ON PLANT | | | LIST. | | | | | | | | | CONDITIONS OF APPROVAL | | | 1. PRIOR TO THE REMOVAL OR RELOCATION OF ANY TREES ON | | | THE PROPERTY, A TREE ALTERATION PERMIT SHALL BE | | | SUBMITTED, REVIEWED AND APPROVED BY THE DEVELOPMENT | | | SERVICES DEPARTMENT, PLANNING DIVISION. | | | | | | 2. THE APPLICANT, SUCCESSORS AND ASSIGNS SHALL BE | | | RESPONSIBLE FOR THE PERMITTING AND INSTALLATION OF THE | | | RIGHT OF WAY LANDSCAPING AND IRRIGATION APPROVED WITH | | | THIS PETITION. | | | | | | | | | 3. THE APPLICANT, SUCCESSORS AND ASSIGNS SHALL BE | | | RESPONSIBLE FOR THE MAINTENANCE OF THE STREETSCAPE | | | LANDSCAPING AND IRRIGATION. THIS WILL BE THROUGH A | | | SEPARATE MAINTENANCE AGREEMENT WITH THE CITY. | | | | | | |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
1 |
Status |
F |
Date |
03-07-2022 |
|
|
Cont ID |
|
| Sent By |
rcaranci |
Date |
03-07-2022 |
Time |
14:46 |
Rev Time |
0.00 |
| Received By |
rcaranci |
Date |
03-07-2022 |
Time |
14:46 |
Sent To |
|
|
| Notes |
| 2022-03-07 14:47:27 | FROM: RAY CARANCI, SENIOR LANDSCAPE PLANNER | | | 561-822-1462 | | | PROJECT: 512 CLEMATIS Z22020019 | | | MARCH 7, 2022 | | | I HAVE REVIEWED THE ABOVE REFERENCED PETITION, AND | | | PROVIDE THE FOLLOWING COMMENTS: | | | | | | | | | 1. MAKE THE FOLLOWING CORRECTIONS TO THE TREE | | | DISPOSITION PLAN: | | | ? ARECA PALMS DO NOT REQUIRE MITIGATION. REVISE CHART. | | | ? INDICATE HOW THE 200 SQ FT OF MITIGATION DUE WILL BE | | | PROVIDED. | | | | | | 2. PER SECTION 94-113, THE STREETSCAPE ON QUADRILLE | | | PLAZA DRIVE IS TO BE MODIFIED TO PROVIDE THE 4 FOOT | | | WIDE PLANTING STRIP ALONG THE CURB. THE BASE PLANTINGS | | | AT THE BUILDING WILL BE NARROWED TO PROVIDE THE | | | REQUIRED SIDEWALK WIDTH. | | | | | | 3. IRRIGATION FOR THE ADJACENT QUADRILLE PLAZA DR | | | STREETSCAPE IS TO BE PROVIDED FROM THE SITE. EXISTING | | | IRRIGATION IS TO BE MODIFIED TO REMOVE THIS AREA FROM | | | THE SYSTEM. THE APPLICANT WILL BE RESPONSIBLE FOR | | | RELOCATING THE WATER METER AND BACKFLOW FROM THE SITE | | | TO A LOCATION SPECIFIED BY THE CITY TO SERVICE THE | | | REMAINING AREAS ON THE EAST SIDE OF THE ROAD. FPL SITE | | | TO THE SOUTH WILL BE INSTALLING IRRIGATION FOR THE | | | STREET TREES ADJACENT TO THEIR PROPERTY. | | | | | | 4. THERE IS NOT SUFFICIENT SPACE FOR THE LIVE OAK TREES | | | PROPOSED FOR THE ALLEY. REVISE TO PROVIDE APPROPRIATE | | | PALMS OR SMALL TREES TO ELIMINATE CONFLICT WITH TRAFFIC | | | AND UTILITIES. | | | | | | 5. PROVIDE A DIAGRAM OF THE PROVIDED 25% PRIVATE OPEN | | | SPACE AREAS FOR CWD-CD. IDENTIFY THE TYPE OF OPEN SPACE | | | AS ALLOWED BY TABLE IV-7 AND DEFINITIONS IN SECTION | | | 94-109. SHOW HOW THE STANDARDS FOR THE TYPES OF OPEN | | | SPACE ARE MET INCLUDING VEGETATED AREAS AND TREE CANOPY | | | SQUARE FOOTAGE BASED ON TABLE IV-8. | | | | | | | | | 6. SHOW THE LOCATIONS OF ALL UTILITIES ON THE LANDSCAPE | | | PLAN AND RESOLVE ANY CONFLICTS. | | | THERE APPEAR TO BE CONFLICTS IN LOCATIONS BETWEEN | | | EXISTING STREET TREES WITH THE PROPOSED UTILITIES. | | | | | | | | | | | | 7. THE FLORIDA FRIENDLY DESIGN OPTIONS CHART NEEDS TO | | | BE UPDATED TO CURRENT CODE REQUIREMENTS. SEVERAL ITEMS | | | NEED THE WORDING ADJUSTED TO MATCH CURRENT CODE. | | | | | | 8. REVISE RENDERING TO ACCURATELY SHOW THE LOCATION AND | | | SIZE OF THE EXISTING AND PROPOSED STREET TREES AND | | | LANDSCAPING. | | | | | | | | | CONDITIONS OF APPROVAL | | | 1. PRIOR TO THE REMOVAL OR RELOCATION OF ANY TREES ON | | | THE PROPERTY, A TREE ALTERATION PERMIT SHALL BE | | | SUBMITTED, REVIEWED AND APPROVED BY THE DEVELOPMENT | | | SERVICES DEPARTMENT, PLANNING DIVISION. | | | 2. THE APPLICANT, SUCCESSORS AND ASSIGNS SHALL BE | | | RESPONSIBLE FOR THE PERMITTING AND INSTALLATION OF THE | | | RIGHT OF WAY LANDSCAPING AND IRRIGATION APPROVED WITH | | | THIS PETITION. | | | 3. THE APPLICANT, SUCCESSORS AND ASSIGNS SHALL BE | | | RESPONSIBLE FOR THE MAINTENANCE OF THE STREETSCAPE | | | LANDSCAPING AND IRRIGATION. THIS WILL BE THROUGH A | | | SEPARATE MAINTENANCE AGREEMENT WITH THE CITY. | | | |
|
|
| Review Stop |
PU |
PUBLIC UTILITIES |
| Rev No |
2 |
Status |
P |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
| Received By |
mtechnow |
Date |
08-15-2022 |
Time |
16:58 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
PU |
PUBLIC UTILITIES |
| Rev No |
1 |
Status |
F |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
| Received By |
mtechnow |
Date |
03-09-2022 |
Time |
13:59 |
Sent To |
|
|
| Notes |
| 2022-03-09 14:03:59 | -ADD NOTE THIS PROJECT IS WITH LS 43 SERVICE BOUNDARY. | | | -REPLACE SEWER LINE FRONTING THE PROPERTY UP TO MH IN | | | QUADRILLE PLAZA. | | | -WILL NEED TO POTHOLE/SHOW EXISTING UTILITIES. THIS | | | ALLEY IS CONGESTED. | | | - SEE STANDARD COMMENT LIST. | | | | | | CONTACT MIKE TECHNOW 561-494-1047 OR [email protected] | | | WITH ANY QUESTIONS. |
|
|
| Review Stop |
PU-CS |
PUBLIC UTILITIES CUSTOMER SRVC |
| Rev No |
1 |
Status |
P |
Date |
09-20-2022 |
|
|
Cont ID |
|
| Sent By |
mhurley |
Date |
09-20-2022 |
Time |
16:34 |
Rev Time |
0.00 |
| Received By |
mhurley |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2022-09-20 16:34:38 | APPROVED AS NOTED: | | | -PLANTING PLAN L2.0 STILL SEEMS TO SHOW LOCATION | | | CONFLICTS BETWEEN BACKFLOW ASSEMBLIES AND BUSHES. WILL | | | NEED AT LEAST 18 INCH HORIZONTAL CLEARANCE DISTANCE | | | BETWEEN THEM. | | | -RENDERING L3.0 DOES NOT MATCH PLANTING PLAN AND CANNOT | | | BE USED AS BASIS FOR PLANTING. | | | RESPECTFULLY, | | | MARK HURLEY [email protected] |
|
|
| Review Stop |
STORM |
STORMWATER |
| Rev No |
3 |
Status |
F |
Date |
09-30-2022 |
|
|
Cont ID |
|
| Sent By |
tward |
Date |
09-30-2022 |
Time |
09:04 |
Rev Time |
0.00 |
| Received By |
tward |
Date |
09-30-2022 |
Time |
09:48 |
Sent To |
|
|
| Notes |
| 2022-09-30 09:07:12 | THE FOLLOWING COMMENTS ARE FROM THE REVIEW OF THE | | | 8/31/22. PREVIOUSLY SATISFIED COMMENTS ARE NOT | | | INCLUDED. | | | | | | 8. [SATISFIED] SHOW EXISTING AND PROPOSED UTILITIES ON | | | THE LANDSCAPE PLANS. | | | | | | NEW COMMENTS (4/15/22 SUBMITTAL): | | | | | | 11. [SATISFIED BUT SEE NEW COMMENT #19 BELOW.] | | | REGARDING THE QUADRILLE PLAZA DRIVE R/W DESIGNATION, | | | CHECK WITH VINCE NOEL (561-494-1096) ON HOW IT SHOULD | | | BE LABELED (AS R/W LINE, PARCEL LINE, ETC.) | | | | | | 12. [SATISFIED BUT SEE NEW COMMENT #19 BELOW.] SHOW AND | | | LABELED THE PROPOSED EAST PROPERTY LINE FOR THE | | | DEVELOPMENT. | | | | | | 13. [SATISFIED] MOVE THE STORM MANHOLE OUT OF THE | | | CLEMATIS STREET R/W OR RUN THE STORM PIPE FROM THE | | | PROPOSED CONTROL STRUCTURE TO THE BACK OF THE EXISTING | | | INLET ON CLEMATIS STREET WITHOUT A MANHOLE. | | | | | | 14. [SATISFIED] JUSTIFY ANY OUTFALL PIPE LARGER THAN | | | 15-INCH DIAMETER. | | | | | | 15. [SATISFIED - SEE COMMENT #20 BELOW] BUILDING ON THE | | | CONCEPTUAL ENGINEERING PLAN DOES NOT MATCH THE | | | ARCHITECTURAL SITE PLAN WITH RESPECT TO RECESSS DOOR | | | OPENINGS, BUILDING SHAPE, ETC. | | | | | | 16. [SATISFIED] ADVISE IF THE FPL U.E. WILL CONFLICT | | | WITH THE R-TANKS STORAGE CHAMBERS. | | | | | | 17. [SATISFIED] LABEL THE EAST-WEST DASHED LINE SHOWN | | | NORTH OF THE PROPOSED CONTROL STRUCTURE. | | | | | | 18. [SATISFIED] SHOW SHALLOW SWALE ON TYPICAL SECTION | | | B-B TO PREVENT DIRECT RUNOFF INTO THE ALLEY. | | | | | | NEW COMMENTS (8-31-22 SUBMITTAL) | | | | | | 19. PROPOSED PROPERTY LINES ON THE CONCEPTUAL | | | ENGINEERING PLAN DO NOT APPEAR TO BE SHOWN IN THE | | | CORRECT LOCATION. IT IS STAFF'S UNDERSTANDING THE NORTH | | | PROPERTY LINE WILL COINCIDE WITH THE SOUTH R/W OF | | | CLEMATIS STREET, THE EAST PROPERTY LINE WILL BE 65 FEET | | | WEST OF AND PARALLEL TO THE WEST 100' F.E.C. RAILWAY | | | R/W, AND THE SOUTH PROPERTY LINE WILL COINCIDE WITH THE | | | NORTH R/W OF THE 14' ALLEY. ALSO REVISE THE PL LABELED | | | ON SECTION B-B. | | | | | | 20. THE WEST SIDE OF THE DRIVEWAY TO THE ALLEY DOES | | | NOTT APPEAR TO LINE UP WITH THE WALL OPENING. THIS CAN | | | BE CORRECTED WITH THE ENGINEERING PERMIT SUBMITTAL. | | | | | | 21. LABEL THE STORM PIPE IN THE R/W AS RCP. | | | | | | 22. PROVIDE INFORMATION (RIM, INVERTS, BOTTOM | | | ELEVATION) OF THE EXISTING CATCH BASIN THAT THE | | | STORMWATER PIPE WILL CONNECT TO. THIS CAN BE PROVIDED | | | WITH THE ENGINEERING PERMIT SUBMITTAL. | | | | | | 23. SHOW AND PROVIDE INFORMATION (TYPE, SIZE, MATERIAL, | | | ELEVATION) OF DRY UTILITIES IN THE R/W. THIS CAN BE | | | PROVIDED WITH THE ENGINEERING PERMIT SUBMITTAL. | | | | | | TRACY WARD, PE | | | SENIOR STORMWATER ENGINEER | | | ENGINEERING SERVICES DEPARTMENT | | | 561-494-1120 (O) | | | [email protected] | | | |
|
|
| Review Stop |
STORM |
STORMWATER |
| Rev No |
2 |
Status |
F |
Date |
08-05-2022 |
|
|
Cont ID |
|
| Sent By |
tward |
Date |
08-05-2022 |
Time |
09:55 |
Rev Time |
0.00 |
| Received By |
tward |
Date |
08-05-2022 |
Time |
10:34 |
Sent To |
|
|
| Notes |
| 2022-08-05 10:33:56 | THE FOLLOWING COMMENTS ARE FROM THE REVIEW OF THE | | | 4/15/2022 SUBMTITAL: | | | | | | 1. [SATISFIED] NGVD1929 TO NAVD1988 CONVERSION EQUATION | | | IS DIFFERENT BETWEEN THE SURVEY AND THE ENGINEERING | | | PLAN. | | | | | | 2. [SATISFIED] REDUCE THE AMOUNT OF DRAINAGE PIPE IN | | | THE RIGHT OF WAY BY CONNECTING TO THE EXISTING VALLEY | | | GUTTER INLET BETWEEN THE ON-STREET PARKING SPACES. | | | | | | 3. [SATISFIED] LABEL THE ONSITE DRAINAGE CONTROL | | | STRUCTURE. | | | | | | 4. [SATISFIED] THERE IS A PROPOSED FPL CHARGING STATION | | | PROJECT ON THE SOUTH SIDE OF THE ALLEY. SHOW THE | | | DRIVEWAY OPENING AND OTHER PROPOSED IMPROVEMENTS ALONG | | | THE SOUTH R/W OF THE ALLEY FROM THAT PROJECT ON THE | | | CONCEPTUAL ENGINEERING PLAN. | | | | | | 5. [SATISFIED] REVIEW THE CITY'S PROPOSED UTILITY | | | PROJECT IN THE ALLEY BETWEEN ROSEMARY AVE AND QUADRILLE | | | PLAZA DRIVE. | | | | | | 6. [SATISFIED - SEE COMMENT BELOW] LABEL THE WEST RIGHT | | | OF WAY LINE OF QUADRILLE PLAZA DRIVE. | | | | | | 7. [SATISFIED BASED ON EOR RESPONSE] GARAGE OPENING TO | | | BE OF SUFFICIENT HEIGHT FOR MAINTENANCE VEHICLES TO | | | ACCESS THE DRAINAGE SYSTEM UNDER THE BUILDING. | | | | | | 8. [NOT SATISFIED] SHOW EXISTING AND PROPOSED UTILITIES | | | ON THE LANDSCAPE PLANS. | | | | | | 9. [SATISFIED - SEE ADDITIONAL COMMENT BELOW] PROVIDE | | | CROSS SECTIONS FROM SOUTH ALLEY RIGHT OF WAY TO FACE OF | | | BUILDING AND TO 30 FEET INSIDE BUILDING AT THE | | | DRIVEWAY. LABEL RIGHT OF WAY LINES AND PROVIDE | | | DIMENSIONS FROM THE RIGHT OF WAY TO BUILDING FACE AND | | | SHOW GENERAL SURFACE SLOPES. | | | | | | 10. [SATISFIED] EXTRA SET OF DOORS SHOWN ON CONCEPTUAL | | | ENGINEERING PLAN OPENING ON QUADRILLE PLAZA DRIVE. | | | | | | NEW COMMENTS: | | | | | | 11. REGARDING THE QUADRILLE PLAZA DRIVE R/W | | | DESIGNATION, CHECK WITH VINCE NOEL (561-494-1096) ON | | | HOW IT SHOULD BE LABELED (AS R/W LINE, PARCEL LINE, | | | ETC.) | | | | | | 12. SHOW AND LABELED THE PROPOSED EAST PROPERTY LINE | | | FOR THE DEVELOIPMENT. | | | | | | 13. MOVE THE STORM MANHOLE OUT OF THE CLEMATIS STREET | | | R/W OR RUN THE STORM PIPE FROM THE PROPOSED CONTROL | | | STRUCTURE TO THE BACK OF THE EXISTING INLET ON CLEMATIS | | | STREET WITHOUT A MANHOLE. | | | | | | 14. JUSTIFY ANY OUTFALL PIPE LARGER THAN 15-INCH | | | DIAMETER. | | | | | | 15. BUILDING ON THE CONCEPTUAL ENGINEERING PLAN DOES | | | NOT MATCH THE ARCHITECTURAL SITE PLAN WITH RESPECT TO | | | RECESSS DOOR OPENINGS, BUILDING SHAPE, ETC. | | | | | | 16. ADVISE IF THE FPL U.E. WILL CONFLICT WITH THE | | | R-TANKS STORAGE CHAMBERS. | | | | | | 17. LABEL THE EAST-WEST DASHED LINE SHOWN NORTH OF THE | | | PROPOSED CONTROL STRUCTURE. | | | | | | 18. SHOW SHALLOW SWALE ON TYPICAL SECTION B-B TO | | | PREVENT DIRECT RUNOFF INTO THE ALLEY. | | | | | | TRACY WARD, PE | | | SENIOR STORMWATER ENGINEER | | | ENGINEERING SERVICES DEPARTMENT | | | 561-494-1120 (O) | | | 561-351-0510 (M) | | | [email protected] | | | |
|
|
| Review Stop |
STORM |
STORMWATER |
| Rev No |
1 |
Status |
F |
Date |
03-09-2022 |
|
|
Cont ID |
|
| Sent By |
tward |
Date |
03-09-2022 |
Time |
09:52 |
Rev Time |
0.00 |
| Received By |
tward |
Date |
03-09-2022 |
Time |
09:55 |
Sent To |
|
|
| Notes |
| 2022-03-09 09:54:59 | THIS IS A CONCEPTUAL LEVEL REVIEW. CONSTRUCTION LEVEL | | | DETAILS, DESIGN CALCULATIONS AND THE POLLUTION | | | PREVENTION PLAN WILL BE REVIEWED AS PART OF THE | | | ENGINEERING DEVELOPMENT APPROVAL AND BUILDING PERMIT | | | APPLICATION PROCESSES. | | | | | | THE FOLLOWING COMMENTS MUST BE ADDRESSED PRIOR TO SITE | | | PLAN APPROVAL: | | | | | | 1. NGVD1929 TO NAVD1988 CONVERSION EQUATION IS | | | DIFFERENT BETWEEN THE SURVEY AND THE ENGINEERING PLAN. | | | | | | 2. REDUCE THE AMOUNT OF DRAINAGE PIPE IN THE RIGHT OF | | | WAY BY CONNECTING TO THE EXISTING VALLEY GUTTER INLET | | | BETWEEN THE ON-STREET PARKING SPACES. | | | | | | 3. LABEL THE ONSITE DRAINAGE CONTROL STRUCTURE. | | | | | | 4. THERE IS A PROPOSED FPL CHARGING STATION PROJECT ON | | | THE SOUTH SIDE OF THE ALLEY. SHOW THE DRIVEWAY OPENING | | | AND OTHER PROPOSED IMPROVEMENTS ALONG THE SOUTH R/W OF | | | THE ALLEY FROM THAT PROJECT ON THE CONCEPTUAL | | | ENGINEERING PLAN. | | | | | | 5. REVIEW THE CITY?S PROPOSED UTILITY PROJECT IN THE | | | ALLEY BETWEEN ROSEMARY AVE AND QUADRILLE PLAZA DRIVE. | | | | | | 6. LABEL THE WEST RIGHT OF WAY LINE OF QUADRILLE PLAZA | | | DRIVE. | | | | | | 7. GARAGE OPENING TO BE OF SUFFICIENT HEIGHT FOR | | | MAINTENANCE VEHICLES TO ACCESS THE DRAINAGE SYSTEM | | | UNDER THE BUILDING. | | | | | | 8. SHOW EXISTING AND PROPOSED UTILITIES ON THE | | | LANDSCAPE PLANS. | | | | | | 9. PROVIDE CROSS SECTIONS FROM SOUTH ALLEY RIGHT OF WAY | | | TO FACE OF BUILDING AND TO 30 FEET INSIDE BUILDING AT | | | THE DRIVEWAY. LABEL RIGHT OF WAY LINES AND PROVIDE | | | DIMENSIONS FROM THE RIGHT OF WAY TO BUILDING FACE AND | | | SHOW GENERAL SURFACE SLOPES. | | | | | | 10. EXTRA SET OF DOORS SHOWN ON CONCEPTUAL ENGINEERING | | | PLAN OPENING ON QUADRILLE PLAZA DRIVE. | | | | | | | | | THE FOLLOWING COMMENTS MUST BE ADDRESSED PRIOR TO | | | ISSUANCE OF CONSTRUCTION AUTHORIZATION INCLUDING | | | BUILDING PERMITS AND ENGINEERING DEVELOPMENT APPROVAL. | | | | | | 1. DRAINAGE SYSTEM TO BE DESIGNED TO MEET SFWMD ERP | | | CRITERIA. STORMWATER CALCULATIONS WILL BE REVIEWED WITH | | | THE ENGINEERING PERMIT SUBMITTAL. | | | | | | 2. PROVIDE COPY OF SFWMD ERP PERMIT BEFORE START OF | | | CONSTRUCTION, IF REQUIRED. | | | | | | 3. PROVIDE AN EROSION CONTROL PLAN WITH DETAILS. | | | | | | TRACY WARD, PE | | | SENIOR STORMWATER ENGINEER | | | ENGINEERING SERVICES DEPARTMENT | | | 561-494-1120 (O) | | | 561-351-0510 (M) | | | [email protected] | | | |
|
|
| Review Stop |
SURVEY |
SURVEYING |
| Rev No |
2 |
Status |
F |
Date |
08-08-2022 |
|
|
Cont ID |
|
| Sent By |
vnoel |
Date |
08-08-2022 |
Time |
08:50 |
Rev Time |
0.00 |
| Received By |
vnoel |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2022-08-08 08:55:24 | 1. COMMENTS 1 AND 2 NOT SATISFIED. | | | 2. NEED FURTHER DISCUSSION ON MANHOLE IN SIDEWALK. | | | 3. SHOW WHERE BACKFLOW IS TO BE RELOCATED. | | | 4. PROVIDE DOCUMENTATION OF COORDINATION WITH PUBLIC | | | UTILITIES. | | | | | | |
|
|
| Review Stop |
SURVEY |
SURVEYING |
| Rev No |
1 |
Status |
F |
Date |
03-09-2022 |
|
|
Cont ID |
|
| Sent By |
vnoel |
Date |
03-09-2022 |
Time |
09:29 |
Rev Time |
0.00 |
| Received By |
vnoel |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2022-03-09 09:50:07 | 1. SURVEY NEEDS TO INCLUDE ENTIRE PROPERTY AND BE | | | DIGITALLY SIGNED. | | | 2. NEED CONVERSION TO NGVD-29. | | | 3. STORM MANHOLES NEED TO BE RELOCATED OUT OF SIDEWALK. | | | 4. IRRIGATION BACKFLOW IN SE CORNER TO REMAIN AND BE | | | RELOCATED TO SOUTH SIDE OF BUILDING OUTSIDE OF ALLEY | | | ALONG WITH PROPOSED D.C.D.A. | | | 5. COORDINATE WITH PUBLIC UTILITIES FOR PROPOSED ALLEY | | | IMPROVEMENTS. | | | 6. REMOVE NOTE FROM SITE PLAN THAT ALLEY WILL BE | | | REPAVED UNDER SEPARATE SCOPE OF WORK. |
|
|
| Review Stop |
TRAFFIC |
TRAFFIC ENGINEERING |
| Rev No |
3 |
Status |
P |
Date |
10-12-2022 |
|
|
Cont ID |
|
| Sent By |
|
Date |
10-12-2022 |
Time |
|
Rev Time |
0.00 |
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2022-10-12 00:20:27 | NO FURTHER COMMENTS. | | | | | | TRAFFIC ANALYSIS COMMENTS | | | 1) SATISFIED. PROVIDE A FULL TRAFFIC STUDY ACCORDING TO | | | COUNTY???S ARTICLE 12. PLEASE CONTACT THE | | | TRANSPORTATION GROUP TO SCHEDULE A METHODOLOGY MEETING. | | | NOT ALL DISCUSSED ITEMS HAVE BEEN PROVIDED IN THE | | | ANALYSIS. A SECOND METHODOLOGY MEETING IS NEEDED | | | 2) SATISFIED. PROJECT DISTRIBUTION FIGURE. QUADRILLE | | | PLAZA DR IS MISSING | | | 3) SATISFIED. TABLE 1. PROVIDE THE | | | STARRED/SUPERSCRIPTED REFERENCES | | | 4) SATISFIED. TABLE 4. DATURA STREET GOES FROM TAMARIND | | | TO QUADRILLE PLAZA DR | | | 5) SATISFIED. PROVIDE TABLE(S) AND/OR REFERENCES | | | HIGHLIGHTING SIGNIFICANTLY IMPACTED STREETS AND | | | INTERSECTIONS | | | 6) SATISFIED. PROVIDE COUNTY TPS LETTER, ONCE OBTAINED | | | 7) SATISFIED. THE ALLEYWAY IS PLANNED TO BE DESIGNATED | | | ONE-WAY EASTBOUND. SHOWCASE CORRESPONDING PAVEMENT | | | MARKING AND SIGNAGE | | | 8) SATISFIED. MAJOR IMPACTED CORRIDORS AND | | | INTERSECTIONS NEED TO BE FURTHER ANALYZED. PLEASE | | | CONTACT ENGINEERING SERVICES TO COORDINATE THIS ITEM | | | 9) SATISFIED. PLEASE PROVIDE AN INITIAL LIST OF TDM | | | MEASURES | | | 10) SATISFIED. PLEASE INCLUDE THE LATEST SITE PLAN IN | | | THE APPENDIX | | | | | | SITE PLANS COMMENTS | | | 11) SATISFIED. PROVIDE A CLEAN TRANSPORTATION SPECIFIC | | | SITE PLAN FOR THE GROUND FLOOR. SHOWCASING | | | TRANSPORTATION RELATED FEATURES (E.G. ROADWAY WIDTHS, | | | DRIVING AISLES, PARKING STALLS, SIDEWALK, CURB, GUTTER, | | | DRIVEWAY, GATES, CROSSWALKS, SIGNAGE & PAVEMENT | | | MARKINGS ETC.) PROPERLY LABELED AND DIMENSIONED. SHEET | | | A-1 IS A STARTING POINT. MISSING SEVERAL DIMENSIONS: | | | ALLEY WIDTH, | | | 12) SATISFIED. ON THE SITE PLAN, PLEASE SHOWCASE BASIC | | | CURB DETAILS (I.E. DRIVEWAY AND PARKING STALLS) ON THE | | | OPPOSITE SIDE OF THE ROADS SURROUNDING THE PROPOSED | | | DEVELOPMENT. PLEASE PROVIDE DOCUMENT NAME AND SHEET | | | NUMBER SHOWCASING SUCH FEATURES | | | 13) SATISFIED. PROVIDE AUTOTURN ANALYSIS FOR GARBAGE | | | TRUCK AND/OR SERVICE VEHICLES DRIVING IN AND OUT OF THE | | | PROPOSED DEVELOPMENT WITH VEHICLE DYNAMIC ENVELOPES | | | CLEARLY DEFINED. ANALYSIS SHOULD BE PROVIDED IN A | | | SEPARATE FILE/DRAWING. PLEASE PROVIDE DOCUMENT NAME AND | | | SHEET NUMBER IN THE RESPONSE LETTER | | | 14) SATISFIED. IDENTIFY AND DESIGNATE AN EASILY | | | ACCESSIBLE MICRO-MOBILITY STATION AREA (MINIMUM 8 X 20 | | | FEET) AND PROVIDE BASIC ELECTRIFICATION READINESS. FOR | | | THE LATTER ITEM, MORE SPECIFICALLY: A CONDUIT (2 INCH | | | SCHEDULE 40 PVC) TO THE POWER SOURCE WITH AN ELECTRICAL | | | PULL BOX (240V CIRCUIT). PLEASE PROVIDE DOCUMENT NAME | | | AND SHEET NUMBER SHOWCASING SUCH FEATURE. CITY | | | INSTALLED BIKE SHARE STATION DOES NOT STRICTLY FULFIL | | | THIS REQUIREMENT; FURTHER DISCUSSION IS NEEDED | | | 15) SATISFIED. PROVIDE PARKING TABLE SHOWCASING THE | | | NUMBER OF REQUIRED AND/OR PROVIDED PARKING SPACES, | | | INCLUSIVE OF ADA AND BICYCLE ONES. ARCHITECTURAL PLANS | | | SHOW PARKING STALLS AND BIKE RACKS IN THE GROUND FLOOR. | | | PLEASE PROVIDE DOCUMENT NAME AND SHEET NUMBER | | | CONTAINING SUCH TABLE IN THE RESPONSE LETTER | | | 16) SATISFIED. CLEARLY MARK THE REQUIRED LOADING ZONE | | | LOCATION AND ITS DIMENSION | | | 17) SATISFIED. ALLEYWAY MUST BE REPAVED ALONG SITE | | | FRONTAGE, BUT IDEALLY IN FULL BETWEEN QUADRILLE PLAZA | | | DR AND ROSEMARY AVE. PROVIDE STATUS OR OUTCOME OF THE | | | FINAL SCOPE | | | 18) SATISFIED. GATE(S) OPERATIONS SHOULD NOT INTERFERE | | | WITH VEHICULAR TRAFFIC LANES, SIDEWALKS AND BICYCLE | | | LANES. ANY GATE AT THE DRIVEWAY SHOULD BE SET BACK AT | | | LEAST 25 FEET FROM THE BACK OF SIDEWALK AND EDGE OF | | | PAVEMENT. PLEASE REVISE PLANS ACCORDINGLY. THIS IS A | | | MAJOR ITEM TO BE ADDRESSED, AS CURRENT GATES | | | CONFIGURATION AND CORRESPONDING VEHICULAR OPERATIONS | | | WOULD SIGNIFICANTLY AND NEGATIVELY IMPACT THE TRAFFIC | | | FLOW ALONG THE ALLEYWAY | | | 19) SATISFIED. SIDEWALKS: A MINIMUM OF 8 FEET | | | UNOBSTRUCTED WALKABLE AREA NEEDS TO BE PROVIDED. | | | LANDSCAPE OR PLANTING AREAS DO NOT COUNT TOWARDS SUCH | | | WIDTH | | | | | | VALERIO ORICCHIO | | | CITY TRANSPORTATION ENGINEER | | | 561-494-1092 | | | [email protected] | | | | | | |
|
|
| Review Stop |
TRAFFIC |
TRAFFIC ENGINEERING |
| Rev No |
2 |
Status |
F |
Date |
08-12-2022 |
|
|
Cont ID |
|
| Sent By |
|
Date |
08-12-2022 |
Time |
|
Rev Time |
0.00 |
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2022-08-12 16:17:58 | TRAFFIC ANALYSIS COMMENTS | | | 1) PARTIALLY SATISFIED. PROVIDE A FULL TRAFFIC STUDY | | | ACCORDING TO COUNTY ARTICLE 12. PLEASE CONTACT THE | | | TRANSPORTATION GROUP TO SCHEDULE A METHODOLOGY MEETING. | | | NOT ALL DISCUSSED ITEMS HAVE BEEN PROVIDED IN THE | | | ANALYSIS. A SECOND METHODOLOGY MEETING IS NEEDED | | | 2) SATISFIED. PROJECT DISTRIBUTION FIGURE. QUADRILLE | | | PLAZA DR IS MISSING | | | 3) SATISFIED. TABLE 1. PROVIDE THE | | | STARRED/SUPERSCRIPTED REFERENCES | | | 4) SATISFIED. TABLE 4. DATURA STREET GOES FROM TAMARIND | | | TO QUADRILLE PLAZA DR | | | 5) SATISFIED. PROVIDE TABLE(S) AND/OR REFERENCES | | | HIGHLIGHTING SIGNIFICANTLY IMPACTED STREETS AND | | | INTERSECTIONS | | | 6) SATISFIED. PROVIDE COUNTY TPS LETTER, ONCE OBTAINED | | | 7) SATISFIED. THE ALLEYWAY IS PLANNED TO BE DESIGNATED | | | ONE-WAY EASTBOUND. SHOWCASE CORRESPONDING PAVEMENT | | | MARKING AND SIGNAGE | | | 8) MAJOR IMPACTED CORRIDORS AND INTERSECTIONS NEED TO | | | BE FURTHER ANALYZED. PLEASE CONTACT ENGINEERING | | | SERVICES TO COORDINATE THIS ITEM | | | 9) PLEASE PROVIDE AN INITIAL LIST OF TDM MEASURES | | | 10) PLEASE INCLUDE THE LATEST SITE PLAN IN THE APPENDIX | | | | | | SITE PLANS COMMENTS | | | 11) PROVIDE A CLEAN TRANSPORTATION SPECIFIC SITE PLAN | | | FOR THE GROUND FLOOR. SHOWCASING TRANSPORTATION RELATED | | | FEATURES (E.G. ROADWAY WIDTHS, DRIVING AISLES, PARKING | | | STALLS, SIDEWALK, CURB, GUTTER, DRIVEWAY, GATES, | | | CROSSWALKS, SIGNAGE & PAVEMENT MARKINGS ETC.) PROPERLY | | | LABELED AND DIMENSIONED. SHEET A-1 IS A STARTING POINT. | | | 12) SATISFIED. ON THE SITE PLAN, PLEASE SHOWCASE BASIC | | | CURB DETAILS (I.E. DRIVEWAY AND PARKING STALLS) ON THE | | | OPPOSITE SIDE OF THE ROADS SURROUNDING THE PROPOSED | | | DEVELOPMENT. PLEASE PROVIDE DOCUMENT NAME AND SHEET | | | NUMBER SHOWCASING SUCH FEATURES | | | 13) NOT SATISFIED. PROVIDE AUTOTURN ANALYSIS FOR | | | GARBAGE TRUCK AND/OR SERVICE VEHICLES DRIVING IN AND | | | OUT OF THE PROPOSED DEVELOPMENT WITH VEHICLE DYNAMIC | | | ENVELOPES CLEARLY DEFINED. ANALYSIS SHOULD BE PROVIDED | | | IN A SEPARATE FILE/DRAWING. PLEASE PROVIDE DOCUMENT | | | NAME AND SHEET NUMBER IN THE RESPONSE LETTER | | | 14) PARTIALLY SATISFIED. IDENTIFY AND DESIGNATE AN | | | EASILY ACCESSIBLE MICRO-MOBILITY STATION AREA (MINIMUM | | | 8 X 20 FEET) AND PROVIDE BASIC ELECTRIFICATION | | | READINESS. FOR THE LATTER ITEM, MORE SPECIFICALLY: A | | | CONDUIT (2 INCH SCHEDULE 40 PVC) TO THE POWER SOURCE | | | WITH AN ELECTRICAL PULL BOX (240V CIRCUIT). PLEASE | | | PROVIDE DOCUMENT NAME AND SHEET NUMBER SHOWCASING SUCH | | | FEATURE. CITY INSTALLED BIKE SHARE STATION DOES NOT | | | STRICTLY FULFIL THIS REQUIREMENT; FURTHER DISCUSSION IS | | | NEEDED | | | 15) NOT SATISFIED. PROVIDE PARKING TABLE SHOWCASING THE | | | NUMBER OF REQUIRED AND/OR PROVIDED PARKING SPACES, | | | INCLUSIVE OF ADA AND BICYCLE ONES. ARCHITECTURAL PLANS | | | SHOW PARKING STALLS AND BIKE RACKS IN THE GROUND FLOOR. | | | PLEASE PROVIDE DOCUMENT NAME AND SHEET NUMBER | | | CONTAINING SUCH TABLE IN THE RESPONSE LETTER | | | 16) SATISFIED. CLEARLY MARK THE REQUIRED LOADING ZONE | | | LOCATION AND ITS DIMENSION | | | 17) PARTIALLY SATISFIED. ALLEYWAY MUST BE REPAVED ALONG | | | SITE FRONTAGE, BUT IDEALLY IN FULL BETWEEN QUADRILLE | | | PLAZA DR AND ROSEMARY AVE. PROVIDE STATUS OR OUTCOME OF | | | THE FINAL SCOPE | | | 18) GATE(S) OPERATIONS SHOULD NOT INTERFERE WITH | | | VEHICULAR TRAFFIC LANES, SIDEWALKS AND BICYCLE LANES. | | | ANY GATE AT THE DRIVEWAY SHOULD BE SET BACK AT LEAST 25 | | | FEET FROM THE BACK OF SIDEWALK AND EDGE OF PAVEMENT. | | | PLEASE REVISE PLANS ACCORDINGLY. THIS IS A MAJOR ITEM | | | TO BE ADDRESSED, AS CURRENT GATES CONFIGURATION AND | | | CORRESPONDING VEHICULAR OPERATIONS WOULD SIGNIFICANTLY | | | AND NEGATIVELY IMPACT THE TRAFFIC FLOW ALONG THE | | | ALLEYWAY | | | 19) SIDEWALKS: A MINIMUM OF 8 FEET UNOBSTRUCTED | | | WALKABLE AREA NEEDS TO BE PROVIDED. LANDSCAPE OR | | | PLANTING AREAS DO NOT COUNT TOWARDS SUCH WIDTH | | | | | | VALERIO ORICCHIO | | | CITY TRANSPORTATION ENGINEER | | | 561-494-1092 | | | [email protected] | | | | | | |
|
|
| Review Stop |
TRAFFIC |
TRAFFIC ENGINEERING |
| Rev No |
1 |
Status |
F |
Date |
03-09-2022 |
|
|
Cont ID |
|
| Sent By |
|
Date |
03-09-2022 |
Time |
|
Rev Time |
0.00 |
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2022-03-09 15:47:35 | | | | 1) PROVIDE A FULL TRAFFIC STUDY ACCORDING TO COUNTY'S | | | ARTICLE 12. PLEASE CONTACT THE TRANSPORTATION GROUP TO | | | SCHEDULE A METHODOLOGY MEETING | | | 2) PROJECT DISTRIBUTION FIGURE. QUADRILLE PLAZA DR IS | | | MISSING | | | 3) TABLE 1. PROVIDE THE STARRED/SUPERSCRIPTED | | | REFERENCES | | | 4) TABLE 4. DATURA STREET GOES FROM TAMARIND TO | | | QUADRILLE PLAZA DR | | | 5) PROVIDE TABLE(S) AND/OR REFERENCES HIGHLIGHTING | | | SIGNIFICANTLY IMPACTED STREETS AND INTERSECTIONS | | | 6) PROVIDE COUNTY TPS LETTER, ONCE OBTAINED | | | 7) THE ALLEYWAY IS PLANNED TO BE DESIGNATED ONE-WAY | | | EASTBOUND. SHOWCASE CORRESPONDING PAVEMENT MARKING AND | | | SIGNAGE | | | 8) ON THE SITE PLAN, PLEASE SHOWCASE BASIC CURB DETAILS | | | (I.E. DRIVEWAY AND PARKING STALLS) ON THE OPPOSITE SIDE | | | OF THE ROADS SURROUNDING THE PROPOSED DEVELOPMENT. | | | PLEASE PROVIDE DOCUMENT NAME AND SHEET NUMBER | | | SHOWCASING SUCH FEATURES. | | | 9) PROVIDE AUTOTURN ANALYSIS FOR GARBAGE TRUCK AND/OR | | | SERVICE VEHICLES DRIVING IN AND OUT OF THE PROPOSED | | | DEVELOPMENT WITH VEHICLE DYNAMIC ENVELOPES CLEARLY | | | DEFINED. ANALYSIS SHOULD BE PROVIDED IN A SEPARATE | | | FILE/DRAWING. PLEASE PROVIDE DOCUMENT NAME AND SHEET | | | NUMBER SHOWCASING THE ANALYSIS. | | | 10) IDENTIFY AND DESIGNATE AN EASILY ACCESSIBLE | | | MICRO-MOBILITY STATION AREA (MINIMUM 8 X 20 FEET) AND | | | PROVIDE BASIC ELECTRIFICATION READINESS. FOR THE LATTER | | | ITEM, MORE SPECIFICALLY: A CONDUIT (2" SCHEDULE 40 PVC) | | | TO THE POWER SOURCE WITH AN ELECTRICAL PULL BOX (240V | | | CIRCUIT). PLEASE PROVIDE DOCUMENT NAME AND SHEET NUMBER | | | SHOWCASING SUCH FEATURE. | | | 11) PROVIDE PARKING TABLE SHOWCASING THE NUMBER OF | | | REQUIRED AND PROVIDED PARKING SPACES, INCLUSIVE OF ADA | | | AND BICYCLE ONES | | | 12) CLEARLY MARK THE REQUIRED LOADING ZONE LOCATION AND | | | ITS DIMENSION | | | 13) ALLEYWAY MUST BE REPAVED ALONG SITE FRONTAGE, BUT | | | IDEALLY IN FULL BETWEEN QUADRILLE PLAZA DR AND ROSEMARY | | | AVE | | | | | | | | | VALERIO ORICCHIO | | | CITY TRANSPORTATION ENGINEER | | | 561-494-1092 | | | [email protected] | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
09-30-2022 |
|
|
Cont ID |
|
| Sent By |
aaponte |
Date |
09-30-2022 |
Time |
13:26 |
Rev Time |
0.00 |
| Received By |
aaponte |
Date |
09-30-2022 |
Time |
13:26 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
03-08-2022 |
|
|
Cont ID |
|
| Sent By |
aaponte |
Date |
03-08-2022 |
Time |
16:42 |
Rev Time |
0.00 |
| Received By |
aaponte |
Date |
02-08-2022 |
Time |
16:41 |
Sent To |
|
|
| Notes |
| 2022-03-08 16:44:07 | 1. THIS PROJECT IS PRESENTED AS THE DMP HIP OFF-SITE | | | REQUIREMENT FOR A PROPOSED PROJECT AT THE SE CORNER OF | | | FERN ST AND QUADRILLE BOULEVARD. HOWEVER, THE PARENT | | | PROJECT HAS NOT BEEN SUBMITTED YET, AND STAFF CANNOT | | | VERIFY THE HIP REQUIREMENT. SOME GENERAL COMMENTS FOR | | | CONSIDERATION ARE: | | | A. OFF-SITE UNITS SHALL MATCH THE UNIT SIZE AND TYPE OF | | | THE PARENT PROJECT. A 100% MICRO UNIT PROJECT WILL NOT | | | COMPLY WITH THIS REQUIREMENT UNLESS THE PARENT PROJECT | | | IS A 100% MICRO UNIT PROJECT. | | | B. REQUIRED SET-ASIDE SQUARE FOOTAGE IS NET SF, NOT | | | INCLUDING CORRIDORS. | | | 2. A SURVEY FOR THE CITY-OWNED PARCEL SHALL BE INCLUDED | | | WITH THE APPLICATION. SITE AREA SHALL REFLECT THE | | | INFORMATION PROVIDED IN SURVEY (512 CLEMATIS ARE PER | | | SURVEY = 18,387SF VS 18,361 IN SHEET A-1) | | | 3. PROPOSED WEST ELEVATION DOES NOT MEET THE BLANK WALL | | | MAXIMUM REQUIREMENTS. A MAXIMUM OF 20% OF AN ELEVATION | | | CAN BE A BLANK WALL (ABSENT OF FENESTRATION). PLEASE | | | EXPLORE POSSIBLE WINDOWS COMPLIANT WITH FIRE | | | REQUIREMENTS FOR THE SETBACK PROPOSED OR INCREASE THE | | | SETBACK. | | | 4. PLEASE INDICATE THE LOCATION OF THE EXISTING WINDOW | | | ON ADJACENT BUILDING AND CHANGES NEEDED TO COMPLY WITH | | | FIRE CODE, IF REQUIRED. | | | 5. FIRE DCDA ALONG QUADRILLE PLAZA DRIVE SHALL BE | | | RELOCATED TO THE ALLEY. | | | 6. IRRIGATION METER SHALL BE RELOCATED TO THE ALLEY. | | | 7. PROPOSED MANHOLES WILL NOT BE PERMITTED ALONG | | | CLEMATIS STREET. | | | 8. PROPOSED DOORS ALONG FA?ADE SHALL NOT ENCROACH MORE | | | THAN 18 INCHES INTO THE MINIMUM SETBACK. | | | 9. PLEASE PROVIDE INFORMATION TO CONFIRM COMPLIANCE | | | WITH MICRO-UNIT REGULATIONS IN SEC 94-106 (8.A) | | | REGARDING CAR SHARING AND BIKE PARKING. PLEASE INDICATE | | | THE LOCATION OF THE MICRO-MOBILITY STATION ALONG | | | CLEMATIS STREET. | | | 10. BASED ON THE CURRENT PROPOSAL TO PROVIDE 89 MICRO | | | UNITS, THE PROJECT IS REQUIRED TO PAY $10 PER | | | UNIT/MONTH TO SUPPORT THE TROLLEY OPERATION. IF THE | | | PROJECT PARTICIPATES IN THE HIP TROLLEY CONTRIBUTION | | | WILL NOT BE REQUIRED. | | | 11. PLEASE PROVIDE INFORMATION TO CONFIRM COMPLIANCE | | | WITH THE BIKE PARKING REQUIREMENT ALONG THE STREET | | | FRONTAGE (1 SPACE /100 FEET OF FRONTAGE). | | | 12. STREETSCAPE DESIGN ALONG QUADRILLE PLAZA DRIVE | | | SHALL BE AS FOLLOWS: | | | A. PLANTING STRIP SHALL BE PROVIDED BETWEEN THE | | | EXISTING TREES (4 FEET IN WIDTH). | | | B. BASE PLANTING ALONG EAST ELEVATION SHALL BE REDUCED | | | TO 2 FEET IN WIDTH TO ACCOMMODATE A 10 FEET WIDE | | | SIDEWALK. | | | 13. PLEASE INDICATE IF THE PROPOSED PARKING AT GROUND | | | FLOOR IS FOR RETAIL OR RESIDENTIAL TENANTS. | | | 14. LOADING IS NOT REQUIRED FOR THIS PROJECT (LESS THAN | | | 50,000SF LOT) HOWEVER CONSIDERING THE POSSIBLE HIGH | | | TURN-AROUND OF MICROUNITS STAFF RECOMMENDS THE PROJECT | | | TO ACCOMMODATE SOME LOADING FROM THE ALLEY. THE AREA IS | | | ALREADY VERY CONGESTED WITH COMMERCIAL DELIVERIES. | | | 15. PLEASE CLARIFY IF THE MICROUNITS ARE PROPOSED AS | | | FULLY FURNISHED UNITS. | | | 16. PLEASE PROVIDE INFORMATION TO CONFIRM COMPLIANCE | | | WITH REQUIRED SCREENING FOR ROOF TOP MECHANICAL | | | EQUIPMENT. A SCREEN SHALL BE PROVIDED AROUND THE | | | EQUIPMENT AS CLOSE AS PERMITTED BY THE EQUIPMENT | | | CLEARANCE REQUIREMENT. | | | 17. EXTERIOR CORRIDORS (2ND FLOOR) SHALL BE COUNTED AS | | | PART OF THE GROSS BUILDING AREA. | | | 18. PLEASE IDENTIFY IF ANY HORIZONTAL PROJECTIONS ARE | | | ENCROACHING INTO THE ROW. CANOPY OVER QUADRILLE PLAZA | | | DRIVE? | | | PLEASE RESUBMIT ONE PRINTED COPY OF REVISED DRAWINGS | | | AND A RESPONSE SHEET AND ELECTRONIC COPIES OF ALL | | | DOCUMENTS. | | | FOR ADDITIONAL INFORMATION PLEASE CONTACT ANA MARIA | | | APONTE AT 561-822-1439. |
|
|
| |