Plan Review Details - Project Z21070036
Plan Review Stops For Project Z21070036
Review Stop AIPP ART IN PUBLIC PLACES
Rev No 1 Status F Date 08-26-2021 Cont ID  
Sent By eschneid Date 08-26-2021 Time 12:14 Rev Time 0.00
Received By eschneid Date 08-26-2021 Time 12:14 Sent To  
Notes
2021-08-26 12:15:43I SPOKE WITH DAVID MILLAGE AT COTLEUR & HEARING AND
 REVIEWED THE COMMENT WITH PUBLIC ART THIS MORNING.
  
 PLEASE NOTE THAT THEIR IDENTIFIED LOCATION IS NOT
 APPLICABLE TO SATISFY THE PUBLIC ART REQUIREMENT. IF
 THEY CHOOSE TO ADD ART FOR THEIR OWN PURPOSE THEY MAY
 DO SO HOWEVER IT WILL NOT APPLY TO THE CITY?S PUBLIC
 ART REQUIREMENT. MORSELIFE IS SUBJECT TO THE PUBLIC ART
 REQUIREMENT FOR THE NEW DEVELOPMENT ON THE NORTH SIDE
 OF THEIR CAMPUS.
  
 I REVIEWED THE FOLLOWING WITH MR. MILLAGE:
  
 SECTION 78-122 EXTERIOR MEANS ANY PLACE, PUBLIC OR
 PRIVATE, OUTDOOR AND EXTERIOR TO BUILDINGS OR
 STRUCTURES
 AND EXPOSED TO PUBLIC VIEW, INCLUDING, BUT NOT LIMITED
 TO, BUILDINGS, PARKS, RIGHT-OF-WAY MEDIANS
 AND OPEN SPACES.
  
 PUBLIC ART ASSESSMENT MEANS THE ASSESSMENT OF ONE
 PERCENT OF THE TOTAL DOLLAR AMOUNT OF
 THE CONSTRUCTION COSTS OF PRIVATE DEVELOPMENT THAT
 EQUALS OR EXCEEDS $500,000, WHICH MAY BE
 DISCOUNTED AS PROVIDED IN THIS ARTICLE.
  
 PUBLIC PLACE MEANS ANY PLACE, PUBLIC OR PRIVATE,
 EXPOSED TO PUBLIC VIEW, INCLUDING, BUT NOT
 LIMITED TO, BUILDINGS, PARKS, RIGHT-OF-WAY MEDIANS AND
 OPEN SPACES. OR ANY PLACE OWNED AND
 OPERATED BY A GOVERNMENT OR GOVERNMENTAL ENTITY AND
 WHICH IS ACCESSIBLE TO THE PUBLIC.
  
 SYBILLE WELTER
 ADMINISTRATOR OF PUBLIC ART AND CULTURE
 CITY OF WEST PALM BEACH
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 09-13-2021 Cont ID  
Sent By rbrown Date 09-13-2021 Time 20:43 Rev Time 0.00
Received By rbrown Date 09-13-2021 Time 20:43 Sent To  
Notes
2021-09-13 20:44:58FOR SITE PLAN REVIEW PURPOSES. A FULL BUILDING PERMIT
 APPLICATION MUST BE SUBMITTED.

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 09-09-2021 Cont ID  
Sent By pleduc Date 09-09-2021 Time   Rev Time 0.00
Received By pleduc Date 09-09-2021 Time 16:37 Sent To  
Notes
***NONE***

Review Stop L LANDSCAPING
Rev No 1 Status P Date 08-27-2021 Cont ID  
Sent By rcaranci Date 08-27-2021 Time 16:29 Rev Time 0.00
Received By rcaranci Date 08-27-2021 Time 16:29 Sent To  
Notes
2021-08-27 16:30:13CONDITIONS OF APPROVAL
 1. PRIOR TO THE REMOVAL OR RELOCATION OF ANY TREES ON
 THE PROPERTY, A TREE ALTERATION PERMIT SHALL BE
 SUBMITTED, REVIEWED AND APPROVED BY THE DEVELOPMENT
 SERVICES DEPARTMENT, PLANNING DIVISION.
  

Review Stop Z ZONING
Rev No 2 Status P Date 10-18-2022 Cont ID  
Sent By eschneid Date 09-21-2021 Time 11:18 Rev Time 0.00
Received By eschneid Date 09-21-2021 Time 11:19 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 09-07-2021 Cont ID  
Sent By eschneid Date 09-07-2021 Time 17:08 Rev Time 1.50
Received By eschneid Date 09-07-2021 Time 14:26 Sent To  
Notes
2021-09-07 17:08:46CASE NO. PB 1248II
 MORSELIFE DOG PARK ETC.
 4850 RYNA GREENBAUM DRIVE
  
 - CONTACT ERIC SCHNEIDER @ (561) 822-1446,
 [email protected]
  
 - PLEASE PROVIDE RESPONSES TO REVIEW COMMENTS IN
 WRITTEN FORMAT.
  
 - WHEN RESUBMITTING, PLEASE PROVIDE A MINIMUM OF TWO
 (2) PAPER COPIES AND AN ELECTRONIC COPY IN PDF FORMAT
 OF ALL PLANS. PLEASE NOTE THAT CHANGES ON THE
 RESUBMITTED PLANS OR THE SUBMITTAL OF INFORMATION/PLANS
 TO ADDRESS THE COMMENTS MAY RESULT IN ADDITIONAL
 COMMENTS.
  
 - PLEASE NOTE THAT IF THE PLANNING DIVISION HAS NOT
 RECEIVED A RESPONSE WITHIN 60 DAYS FROM THE DATE OF
 THESE COMMENTS (BY NOVEMBER 7, 2021), THE PLANNING
 DIVISION MAY NOTIFY THE APPLICANT THAT THE CASE IS
 CONSIDERED WITHDRAWN. ANY FURTHER ACTION SHALL REQUIRE
 A NEW DEVELOPMENT APPLICATION.
  
 DOG PARK - NO COMMENTS.
  
 SCULPTURE - NO COMMENTS.
  
 SHUFFLEBOARD - NO COMMENTS.
  
 WALK-IN COOLER:
  
 1) SHEET L102 AND SHEET A1 SHOW DIFFERENT MEASURE
 POINTS AND POSSIBLY DIMENSIONS FOR THE FREEZER AREA.
 STAFF WAS UNABLE TO VERIFY ANY DIMENSIONS BE SCALING
 THE PLANS SINCE THE PLAN SCALE LISTED DOES NOT MATCH
 THE DIMENSIONS ON EITHER PLAN. NOTE: THE SCALE ON SHEET
 L102 DOES NOT MATCH WHAT IS LISTED AS 1:30 - IT APPEARS
 SHRUNK ON THE PAGE. THE FREEZER UNIT DIMENSIONS (WHEN
 SCALED FROM THE ELEVATION AND SECTION DRAWINGS) MATCH
 THE FREEZER PAD DIMENSIONS. THE CANOPY WIDTH ALSO SEEMS
 TO MATCH. THE DEPTH OF THE CANOPY IS NOT CORRECT.
  
 2) STAFF NEEDS TO BE ABLE TO VERIFY THAT THE DRIVE
 AISLE CLEARANCE OF 20 FEET IS MAINTAINED FROM THE
 PROPOSED BOLLARD AND THE CURB ON THE NORTH SIDE OF THE
 DRIVE AISLE.
  
  
  
  