Plan Review Details - Project Z21070014
Plan Review Stops For Project Z21070014
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status   Date 08-11-2021 Cont ID  
Sent By rbrown Date 08-11-2021 Time 20:13 Rev Time 0.00
Received By rbrown Date 08-11-2021 Time 20:13 Sent To  
Notes
2021-08-11 20:14:12NO COMMENTS ON THE DESCRIBED AMENDMENTS.

Review Stop ENG - PPRC ENGINEERING - PPRC
Rev No 2 Status P Date 10-13-2021 Cont ID  
Sent By rrossano Date 10-13-2021 Time   Rev Time 0.00
Received By rrossano Date 10-13-2021 Time   Sent To  
Notes
***NONE***

Review Stop ENG - PPRC ENGINEERING - PPRC
Rev No 1 Status F Date 08-05-2021 Cont ID  
Sent By rrossano Date 08-05-2021 Time   Rev Time  
Received By rrossano Date 08-05-2021 Time   Sent To  
Notes
2021-08-10 07:13:52RICK ROSSANO, PROJECT COORDINATOR, ENGINEERING SERVICES
 DEPT., 561-494-1098 [email protected] :
  
 PLEASE CHANGE PROPOSED 3 IN. POLY WATER SERVICE TO 4
 IN. DIP (ON ACACIA FOR 1101 S. FLAGLER DR.).
  
 MARK HURLEY, CITY OF WPB PUB. UTIL. FIELD CUSTOMER SVC.
 SUPV., [email protected]. 561-822-2262:
  
 -UTILITY PLAN SHOWS REPLACEMENT OF WATER SERVICE FOR
 1101 S. FLAGLER DR. IN ACACIA ROAD. THAT WATER SERVICE
 MAY NOT EXIST CURRENTLY, BUT IF IT DOES 3 INCH POLY
 SHOULD NOT BE USED. WOULD NEED TO BE DIP.
  
 -PALM BEACH ATLANTIC COLLEGE HAS A METERED IRRIGATION
 WATER SERVICE NEAR THE PROPOSED 4 INCH METER. PRIOR
 NOTIFIED APPLICANT TEAM THAT WOULD NEED TO LEAVE IN
 TACT OR GET APPROVAL FROM COLLEGE FOR REMOVAL. PLEASE
 PROVIDE STATUS/OUTCOME.
  
 -PLEASE CHECK THE INV OF ALL SAN MH ON CURRIE CRESCENT
 TO MAKE SURE GRAVITY WILL GO TO ACACIA ROAD.
  
 -CIVIL PLANS SHOW GUY WIRE IN SIDEWALK NEAR SOUTH
 DRIVEWAY. IS THAT AS INTENDED?
  
 -LABEL SERVICE PIPE OF 1.5 INCH IRRIGATION METER FOR
 ACACIA WITH PIPE SIZE AND MATERIAL TYPE.
  
 -AREA SOUTHEAST OF PROPOSED FIRE HYDRANT HAS SEVERAL
 CROSSINGS WITH WATER PIPE AND UNDERGROUND ELECTRIC.
 PLEASE ADD ALL OF THEM TO THE CROSSING TABLE.
  
 -WRONG STANDARD DETAIL FOR LARGE VAULT METER IS
 INCLUDED. PLEASE REPLACE WITH WS-4 AND WS-4.1 REVISION
 SEP2019.
  
 -PIGGING JUMPER ON P-6 DETAIL MUST BE INSTALLED
 ABOVE-GROUND. PROJECT SHOULD BE AWARE AND MAKE SURE NO
 CONFLICTS WITH PLAN.
  
 -WHAT IS THE SIZE OF THE CONVERGING TEE IMMEDIATELY
 DOWNSTREAM OF THE FIRELINE BACKFLOW ASSEMBLIES?

Review Stop L LANDSCAPING
Rev No 3 Status P Date 12-13-2021 Cont ID  
Sent By rcaranci Date 12-13-2021 Time 16:33 Rev Time 0.00
Received By rcaranci Date 12-13-2021 Time 16:33 Sent To  
Notes
2021-12-13 16:37:09FROM: RAY CARANCI, SENIOR LANDSCAPE PLANNER
 561-822-1462
 PROJECT: 1309 S FLAGLER RPD MINOR Z21070014
 DECEMBER 13, 2021
 I HAVE REVIEWED THE ABOVE REFERENCED PETITION, AND
 PROVIDE THE FOLLOWING COMMENTS:
  
 NOTE THAT THE LANDSCAPE PLANS APPROVED WITH THE RPD
 ESTABLISH THE MINIMUM SITE REQUIREMENTS. THE NUMBER OF
 REQUIRED TREES IS WHAT IS SHOWN ON THOSE PLANS. ANY
 REDUCTION WOULD REQUIRE A MAJOR AMENDMENT.
  
 1. SATISFIED. BUFFER TREES FOR THE NORTH BUFFER WAS
 REDUCED BY ONE GUMBO LIMBO THAT FALLS BELOW THE
 APPROVED NUMBER OF TREES THAT WAS APPROVED FOR THE
 BUFFER LENGTH. ADD ONE SHADE TREE BACK TO THE BUFFER.
  
 2. SATISFIED. THE TOTAL NUMBER OF TREES PROPOSED WITH
 THIS PETITION IS 79. THE TOTAL NUMBER APPROVED IS 86. A
 MINIMUM OF 86 TREES MUST BE PROVIDED.
  
 PLEASE REFER TO THE APPROVED PLANS FROM THE PD FOR THE
 TREE AND FLOWERING TREE TOTALS. THEY ARE STILL SHORT 2
 TREES.
  
  
 LANDSCAPE PLAN
 +6 THATCH PALMS AT 3:1 EQUALS 2 TREES.
 -4 REDUCTION OF 4 SHADE TREES,
 +1 ADDITION OF ONE FLOWERING TREE,
 TOTAL REDUCTION OF ONE TREE.
  
 AMENITY DECK
 +4 INCREASE OF 4 GS
 -1 REDUCTION OF ONE TRIPLE VEITCHII
 +1 ADDITION OF 7 THRINAX @ 3:1 EQUALS ONE TREE
 INCREASE OF 4 TREES.
  
 NET INCREASE OF 3 TREES.
  

Review Stop L LANDSCAPING
Rev No 2 Status F Date 09-24-2021 Cont ID  
Sent By rcaranci Date 09-24-2021 Time 16:30 Rev Time 0.00
Received By rcaranci Date 09-24-2021 Time 16:30 Sent To  
Notes
2021-09-24 16:30:30FROM: RAY CARANCI, SENIOR LANDSCAPE PLANNER
 561-822-1462
 PROJECT: 1309 S FLAGLER RPD MINOR Z21070014
 SEPTEMBER 23, 2021
 I HAVE REVIEWED THE ABOVE REFERENCED PETITION, AND
 PROVIDE THE FOLLOWING COMMENTS:
  
 NOTE THAT THE LANDSCAPE PLANS APPROVED WITH THE RPD
 ESTABLISH THE MINIMUM SITE REQUIREMENTS. THE NUMBER OF
 REQUIRED TREES IS WHAT IS SHOWN ON THOSE PLANS. ANY
 REDUCTION WOULD REQUIRE A MAJOR AMENDMENT.
  
 1. SATISFIED. BUFFER TREES FOR THE NORTH BUFFER WAS
 REDUCED BY ONE GUMBO LIMBO THAT FALLS BELOW THE
 APPROVED NUMBER OF TREES THAT WAS APPROVED FOR THE
 BUFFER LENGTH. ADD ONE SHADE TREE BACK TO THE BUFFER.
  
 2. PARTIALLY SATISFIED. THE TOTAL NUMBER OF TREES
 PROPOSED WITH THIS PETITION IS 79. THE TOTAL NUMBER
 APPROVED IS 86. A MINIMUM OF 86 TREES MUST BE PROVIDED.
  
 PLEASE REFER TO THE APPROVED PLANS FROM THE PD FOR THE
 TREE AND FLOWERING TREE TOTALS. THEY ARE STILL SHORT 2
 TREES.
  

Review Stop L LANDSCAPING
Rev No 1 Status F Date 08-10-2021 Cont ID  
Sent By rcaranci Date 08-10-2021 Time 10:49 Rev Time 0.00
Received By rcaranci Date 08-10-2021 Time 10:49 Sent To  
Notes
2021-08-10 10:53:59FROM: RAY CARANCI, SENIOR LANDSCAPE PLANNER
 561-822-1462
 PROJECT: 1309 S FLAGLER RPD MINOR Z21070014
 AUGUST 9, 2021
 I HAVE REVIEWED THE ABOVE REFERENCED PETITION, AND
 PROVIDE THE FOLLOWING COMMENTS:
  
 NOTE THAT THE LANDSCAPE PLANS APPROVED WITH THE RPD
 ESTABLISH THE MINIMUM SITE REQUIREMENTS. THE NUMBER OF
 REQUIRED TREES IS WHAT IS SHOWN ON THOSE PLANS. ANY
 REDUCTION WOULD REQUIRE A MAJOR AMENDMENT.
  
 1. BUFFER TREES FOR THE NORTH BUFFER WAS REDUCED BY ONE
 GUMBO LIMBO THAT FALLS BELOW THE APPROVED NUMBER OF
 TREES THAT WAS APPROVED FOR THE BUFFER LENGTH. ADD ONE
 SHADE TREE BACK TO THE BUFFER.
  
 2. THE TOTAL NUMBER OF TREES PROPOSED WITH THIS
 PETITION IS 79. THE TOTAL NUMBER APPROVED IS 86. A
 MINIMUM OF 86 TREES MUST BE PROVIDED.
  

Review Stop PW PUBLIC WORKS
Rev No 1 Status P Date 08-02-2021 Cont ID  
Sent By   Date 08-02-2021 Time   Rev Time  
Received By   Date 08-02-2021 Time   Sent To  
Notes
2021-08-02 13:01:39NO COMMENTS FROM PUBLIC WORKS
  
 MATT HEJAZI
 DEPT. OF PUBLIC WORKS
 [email protected]

Review Stop STORM STORMWATER
Rev No 1 Status P Date 08-12-2021 Cont ID  
Sent By tward Date 08-12-2021 Time 08:56 Rev Time 0.00
Received By tward Date 08-12-2021 Time 09:12 Sent To  
Notes
***NONE***

Review Stop TRAFFIC TRAFFIC ENGINEERING
Rev No 2 Status P Date 09-24-2021 Cont ID  
Sent By   Date 09-24-2021 Time   Rev Time 0.00
Received By   Date   Time   Sent To  
Notes
2021-09-24 18:12:05PASSED WITH THE FOLLOWING CONDITION: IN THE CASE
 LOADING DOCK OPERATIONS ARE CAUSING MAJOR DISRUPTION OR
 CONGESTION TO TRAFFIC CIRCULATION ON CURRIE CRESCENT
 DURING PEAK-HOUR TIMES (7-9 AM, 4-6 PM). ACCESS AND USE
 OF THE LOADING AREA SHALL BE FORBIDDEN DURING SUCH
 TIMES.
  
 TRAFFIC COMMENTS
 1) SATISFIED. PER THE DELIVERY MANAGEMENT PLAN:
 A. PLEASE PROOF-READ AND RE-SUBMIT THE DOCUMENT
 B. PROVIDE DELIVERY DAYS AND TIMES. IF NO RESTRICTIONS
 ARE CONTEMPLATED, A MEETING WITH THE CITY SHALL BE
 SCHEDULED TO DISCUSS THEM
  
 NOTE: THE PLANNED FLAGLER TOWERS PROJECT, JUST SOUTH OF
 THE PROPOSED DEVELOPMENT, WILL BE USING CURRIE CRESCENT
 FOR SERVICE/DELIVERY VEHICLES MANEUVERING AS WELL.
 THUS, FURTHER SCRUTINY ON THE MATTER IS REQUIRED.
  
 VALERIO ORICCHIO
 CITY TRANSPORTATION ENGINEER
 561-494-1092
 [email protected]
  

Review Stop TRAFFIC TRAFFIC ENGINEERING
Rev No 1 Status F Date 08-12-2021 Cont ID  
Sent By   Date 08-12-2021 Time   Rev Time  
Received By   Date   Time   Sent To  
Notes
2021-08-12 12:17:43TRAFFIC COMMENTS
 1) PER THE DELIVERY MANAGEMENT PLAN:
 A. PLEASE PROOF-READ AND RE-SUBMIT THE DOCUMENT
 B. PROVIDE DELIVERY DAYS AND TIMES. IF NO RESTRICTIONS
 ARE CONTEMPLATED, A MEETING WITH THE CITY SHALL BE
 SCHEDULED TO DISCUSS THEM
  
 NOTE: THE PLANNED FLAGLER TOWERS PROJECT, JUST SOUTH OF
 THE PROPOSED DEVELOPMENT, WILL BE USING CURRIE CRESCENT
 FOR SERVICE/DELIVERY VEHICLES MANEUVERING AS WELL.
 THUS, FURTHER SCRUTINY ON THE MATTER IS REQUIRED.
  
 VALERIO ORICCHIO
 CITY TRANSPORTATION ENGINEER
 561-494-1092
 [email protected]
  
  

Review Stop Z ZONING
Rev No 3 Status P Date 01-19-2022 Cont ID  
Sent By eschneid Date 01-19-2022 Time 17:50 Rev Time 0.75
Received By eschneid Date 01-19-2022 Time 16:14 Sent To  
Notes
2022-01-19 17:50:40PASSED
  
 CONDITION: ANYTHING MORE THAN BATHROOMS (MAY INCLUDE A
 SHOWER) ON THE ROOFTOP ARE CONSIDERED AMENITIES,
 REGARDLESS IF THEY ARE ONLY FOR THE PENTHOUSE UNITS,
 AND ARE THUS NOT PERMITTED TO EXCEED THE HEIGHT
 ALLOWANCE.
  
 CONDITION: DUE TO THE PLACEMENT OF THE NEW COLUMN THAT
 RESTRICTS THE WIDTH OF THE DRIVE AISLE TO 13 FEET,
 TANDEM VALET SPACES B2-04/05 THROUGH B2-12/13 MUST
 ALWAYS REMAIN VALET ONLY (THIS MUST BE INCLUDED IN THE
 CONDOMINIUM DOCUMENTS) AND MAY NOT BE UTILIZED FOR
 SELF-PARKING.
  

Review Stop Z ZONING
Rev No 2 Status F Date 10-15-2021 Cont ID  
Sent By eschneid Date 10-15-2021 Time 12:12 Rev Time 3.00
Received By eschneid Date 10-13-2021 Time 09:57 Sent To  
Notes
2021-10-15 12:00:05PB 1799B - REVIEW OF SEPTAMBER RESUBMITTAL
 1309 S. FLAGLER RPD BUILDING PERMIT BASED MINOR
 AMENDMENT
 1309 SOUTH FLAGLER DRIVE
  
 - CONTACT ERIC SCHNEIDER @ (561) 822-1446,
 [email protected]
  
 - PLEASE PROVIDE RESPONSES TO REVIEW COMMENTS IN
 WRITTEN FORMAT.
  
 - WHEN RESUBMITTING, PLEASE PROVIDE A MINIMUM OF TWO
 (2) PAPER COPIES AND AN ELECTRONIC COPY IN .PNG FORMAT
 OF ALL PLANS. PLEASE NOTE THAT CHANGES ON THE
 RESUBMITTED PLANS OR THE SUBMITTAL OF INFORMATION/PLANS
 TO ADDRESS THE COMMENTS MAY RESULT IN ADDITIONAL
 COMMENTS.
  
 - PLEASE NOTE THAT IF THE PLANNING DIVISION HAS NOT
 RECEIVED A RESPONSE TO THESE COMMENTS WITHIN 60 DAYS
 FROM THE DATE OF ISSUE (BY DECEMBER 15, 2021), THE
 PLANNING DIVISION MAY NOTIFY THE APPLICANT THAT THE
 CASE IS CONSIDERED WITHDRAWN. ANY FURTHER ACTION SHALL
 REQUIRE A NEW DEVELOPMENT APPLICATION.
  
 - PLEASE NOTE THAT YOU WILL BE PERMITTED ONE (1)
 ADDITIONAL RESUBMITTAL AT NO ADDITIONAL COST. IF
 PREVIOUSLY ISSUED COMMENTS CONTINUE TO NOT BE
 SUFFICIENTLY ADDRESSED, THE APPLICANT WILL BE ASSESSED
 A RESUBMITTAL FEE. SUCH FEE WILL BE 20% OF THE ORIGINAL
 APPLICATION FEE ($60).
  
 1) REPEAT COMMENT: THERE ARE INCONSISTENCIES BETWEEN
 THE SITE, CIVIL AND LANDSCAPE PLANS AS TO THE PLACEMENT
 OF THE SCULPTURE PADS NEAR THE VALET ONLY STAGING
 SPACES. ALL THE PLANS NEED TO SHOW THE SAME CONDITIONS.
  
 2) THANK YOU FOR PROVIDING THE BICYCLE ROOM DETAIL. IT
 SHOWS 12 RACKS THAT WILL HOLD ONE BICYCLE EACH, NOT THE
 13 LISTED ON THE SITE DATA SHEET. THE 12 SPACES EXCEED
 CODE MINIMUM; HOWEVER, THE SITE DATA SHEET NEEDS TO
 SHOW CORRECT INFORMATION. PLEASE NOTE THAT THE EMPLOYEE
 RACK HOLDS TWO BICYCLES, SO YOU MAY WISH TO ADD CLARITY
 TO THE TABLE.
  
 3) THANK YOU FOR PROVIDING THE SETBACK FROM THE BASE OF
 THE ANGLED AMENITY SUPPORT COLUMNS TO THE NORTH AND
 SOUTH PROPERTY LINES. HOWEVER, SINCE THE COLUMNS ANGLE
 TOWARD THE PROPERTY LINE, THE MEASURE NEEDS TO BE
 PROVIDED TO THE PORTION OF THE COLUMN THAT IS CLOSEST
 TO THE PROPERTY LINE. STAFF SCALED THE PLANS AND IT
 APPEARS THAT THE REQUIRES SETBACK DIMENSION IS MET;
 HOWEVER, IT MUST BE SHOWN.
  
 4) THE ELEVATION OR SECTION DRAWINGS MUST SHOW A
 DIMENSION TAG TO THE ROOF DECK THAT IS BASED ON THE
 MEAN AVERAGE EXISTING GRADE THAT VERIFIES THAT THE
 BUILDING HEIGHT IS NO TALLER THAN 300 FEET.
  
 5) THE ROOF PLAN SHOWS SAUNAS IN THE BATHROOMS. THIS IS
 NOT PERMITTED. STAFF PERMITS REQUIRED BATHROOMS ONLY AS
 ENCLOSED SPACE FOR ROOFTOP POOLS WHICH EXCEED THE
 BUILDING HEIGHT. THE SAUNA IS AN AMENITY AND THUS MUST
 STAY BELOW THE 300-FOOT BUILDING HEIGHT ALLOWANCE.
 NOTE: THE ORIGINAL ROOF PLAN JUST SHOWED ONE BATHROOM
 WITH A SHOWER. WHY ARE THERE NOW TWO BATHROOMS SHOWN?
  
 6) THE NUBMER OF SPACES ON SHEET G0.01 FOR THE BASEMENT
 1 PARKING LINE IS INCORRECT. THERE ARE 31 PARKING
 SPACES. PLEASE CORRECT THE PLAN.
  
 CONDITION: DUE TO THE PLACEMENT OF THE NEW COLUMN THAT
 RESTRICTS THE WIDTH OF THE DRIVE AISLE TO 13 FEET,
 TANDEM VALET SPACES B2-04/05 THROUGH B2-12/13 MUST
 ALWAYS REMAIN VALET ONLY (THIS MUST BE INCLUDED IN THE
 CONDOMINIUM DOCUMENTS) AND MAY NOT BE UTILIZED FOR
 SELF-PARKING.
  
  

Review Stop Z ZONING
Rev No 1 Status F Date 08-10-2021 Cont ID  
Sent By eschneid Date 08-10-2021 Time 11:49 Rev Time 6.00
Received By eschneid Date 08-10-2021 Time 11:49 Sent To  
Notes
2021-08-10 11:50:08PB 1799B
 1309 S. FLAGLER RPD BUILDING PERMIT BASED MINOR
 AMENDMENT
 1309 SOUTH FLAGLER DRIVE
  
 - CONTACT ERIC SCHNEIDER @ (561) 822-1446,
 [email protected]
  
 - PLEASE PROVIDE RESPONSES TO REVIEW COMMENTS IN
 WRITTEN FORMAT.
  
 - WHEN RESUBMITTING, PLEASE PROVIDE A MINIMUM OF THREE
 (3) PAPER COPIES AND AN ELECTRONIC COPY IN .PNG FORMAT
 OF ALL PLANS. PLEASE NOTE THAT CHANGES ON THE
 RESUBMITTED PLANS OR THE SUBMITTAL OF INFORMATION/PLANS
 TO ADDRESS THE COMMENTS MAY RESULT IN ADDITIONAL
 COMMENTS.
  
 - PLEASE NOTE THAT IF THE PLANNING DIVISION HAS NOT
 RECEIVED A RESPONSE TO THE PPRC COMMENTS WITHIN 60 DAYS
 FROM THE DATE OF THE PPRC MEETING (BY OCTOBER 12,
 2021), THE PLANNING DIVISION MAY NOTIFY THE APPLICANT
 THAT THE CASE IS CONSIDERED WITHDRAWN. ANY FURTHER
 ACTION SHALL REQUIRE A NEW DEVELOPMENT APPLICATION.
  
 - PLEASE NOTE THAT YOU WILL BE PERMITTED ONE (1)
 RESUBMITTAL AT NO ADDITIONAL COST. IF PREVIOUSLY ISSUED
 COMMENTS CONTINUE TO NOT BE SUFFICIENTLY ADDRESSED, THE
 APPLICANT WILL BE ASSESSED A RESUBMITTAL FEE. SUCH FEE
 WILL BE 20% OF THE ORIGINAL APPLICATION FEE ($60).
  
 1) THERE ARE INCONSISTENCIES BETWEEN THE SITE, CIVIL
 AND LANDSCAPE PLANS AS TO THE PLACEMENT OF THE
 SCULPTURE PADS NEAR THE VALET ONLY STAGING SPACES. ALL
 THE PLANS NEED TO SHOW THE SAME CONDITIONS. NOTE: THE
 SHRUB PLAN SHOWS LANDSCAPE MATERIAL OVER ONE OF THE
 PADS.
  
 2) THE ARCHITECTURAL PLANS (EX. SHEETS A1.01 AND A0.01)
 DO NOT SHOW TWO OF THE EASTERNMOST AMENITY DECK SUPPORT
 COLUMNS THAT ARE SHOWN ON THE LANDSCAPE AND CIVIL
 PLANS. ALL THE PLANS NEED TO SHOW THE SAME CONDITIONS.
  
 3) ALL PARKING SPACES AND DRIVE AISLES NEED TO SHOW
 DIMENSIONS.
  
 4) THE PARKING LOT STRIPING IS NOT SHOWN MEETING CITY
 CODE. NO PARKING DETAIL IS INCLUDED.
  
 5) PROVIDE THE SETBACK FROM THE INSIDE CORNER (DENTIST
 LOT CORNER) TO THE EXTERIOR OF THE WALL OF THE UPPER
 PARKING (B1 LEVEL). THIS MAY BE NO CLOSER THAN SEVEN
 (7) FEET.
  
 6) THE GROUND FLOOR IS REQUIRED TO HAVE A SETBACK OF 70
 FEET TO THE EAST PROPERTY LINE. THE PLANS SHOW A
 SETBACK OF ONLY 66 FEET 11 INCHES, WHICH DOES NOT
 COMPLY WITH THE APPROVED WAIVER.
  
 7) PROVIDE THE LAYOUT OF NEW BICYCLE ROOM, WITH
 DIMENSIONS.
  
 8) PROVIDE THE SETBACK FROM THE AMENITY SUPPORT COLUMNS
 TO THE NORTH, SOUTH AND EAST PROPERTY LINES. 49 FEET,
 34 FEET AND 17 FEET, RESPECTIVELY, ARE REQUIRED.
  
 9) TURN OFF THE INCORRECT BACKGROUND LANDSCAPE LAYER
 THAT IS SHOWN ON THE PODIUM LEVEL PLAN (MULTIPLE
 BUILDING CONFLICTS) OR PROVIDE THE LANDSCAPE IN THE
 CORRECT LOCATIONS.
  
 10) PROVIDE SETBACK DIMENSIONS FROM THE EDGE OF THE
 AMENITY DECK TO THE EAST PROPERTY LINE AND THE COLUMN
 ON THE AMENITY DECK TO THE EAST PROPERTY LINE. 10 FEET
 AND 50 FEET, RESPECTIVELY, ARE REQUIRED.
  
 11) THE AMENITY DECK IS REQUIRED TO HAVE A SETBACK OF
 15 FEET 4 INCHES FROM CURRIE CRESCENT. THE PLANS SHOW A
 SETBACK OF ONLY 13 FEET 10 INCHES, WHICH DOES NOT
 COMPLY WITH THE APPROVED WAIVER.
  
 12) PROVIDE THE NORTH, SOUTH AND EAST SETBACK
 DIMENSIONS FROM THE AMENITY FLOOR BUILDING WALLS TO THE
 PROPERTY LINES (REQUIRED 48 FEET, 33 FEET AND 72 FEET,
 RESPECTIVELY) ON THE AMENITY LEVEL PLANS.
  
 13) FLOORS 4 - 24 ARE REQUIRED TO HAVE A SETBACK OF 47
 FEET 9 INCHES FROM THE EAST SIDE PROPERTY LINE. THE
 PLANS SHOW A SETBACK OF ONLY 47 FEET 3 INCHES, WHICH
 DOES NOT COMPLY WITH THE APPROVED WAIVER.
  
 14) PROVIDE AN OVERLAY OF EACH FLOOR TO SHOW THAT THE
 CURVILINEAR PORTIONS OF THE BUILDING ARE NO CLOSER TO
 THE PROPERTY LINES WHERE WAIVERS WERE REQUIRED. NOTE:
 STAFF HAS ALREADY NOTED LOCATIONS WERE THE CLOSEST
 POINT OF THE BUILDING DOES NOT COMPLY WITH THE APPROVED
 SETBACKES, SO THIS REQUIREMENT IS TO VERIFY DEVELOPMENT
 REGULATION NUMBER 17 OF RESOLUTION NO. 13-19 REGARDING
 THE FULL FLOORS.
  
 15) THE ROOF LEVEL PLAN NEEDS TO INCLUDE THE ELEVATION
 TAGS SO STAFF CAN VERIFY THAT THE BUILDING HEIGHT HAS
 NOT BEEN EXCEEDED.
  
 16) PROVIDE VERIFICATION ON HOW THE ARTIFICIAL TURF
 USED FOR THE DOG PARK WILL NOT BE VISIBLE FROM ANY
 PUBLIC RIGHT-OF-WAY.
  
 17) DUE TO THE PLACEMENT OF THE NEW COLUMN THAT
 RESTRICTS THE WIDTH OF THE DRIVE AISLE TO 13 FEET,
 TANDEM VALET SPACES B2-04/05 THROUGH B2-12/13 MUST
 ALWAYS REMAIN VALET ONLY (THIS MUST BE INCLUDED IN THE
 CONDOMINIUM DOCUMENTS) AND MAY NOT BE UTILIZED FOR
 SELF-PARKING.
  
 18) SPACE B1-28, B1-31, B1-11, B1-12, B1-16, B1-17,
 B2-41, B2-76, B2-74, B2-57, B2-58, B2-55, B2-54, B2-50,
 B2-48, B2-47, B2-45, B2-44 AND B2-29 DO NOT PROVIDE
 MUCH SPACE TO OPEN THE CAR DOOR. THIS IS A LUXURY
 CONDOMINIUM PROJECT WITH TIGHT PARKING SPACES. THE
 STAFF HAS HEARD COMPLAINTS FROM OWNERS IN PREVIOUS
 CONDOMINIUMS THAT THE STANDARD WIDTH STALL, WHEN
 AGAINST A WALL DOES NOT PROVIDE THE ABILITY TO OPEN CAR
 DOORS. YOU SHOULD TAKE THIS INTO ACCOUNT WHEN MARKETING
 THE PARKING SPACES IN RELATION TO THE OWNER'S CAR
 SIZES.
  