Plan Review Details - Project Z21050030
| Plan Review Stops For Project Z21050030 |
| Review Stop |
AIPP |
ART IN PUBLIC PLACES |
| Rev No |
1 |
Status |
N |
Date |
07-09-2021 |
|
|
Cont ID |
|
| Sent By |
scwelter |
Date |
07-09-2021 |
Time |
13:54 |
Rev Time |
0.00 |
| Received By |
scwelter |
Date |
07-09-2021 |
Time |
13:55 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
07-07-2021 |
|
|
Cont ID |
|
| Sent By |
rbrown |
Date |
07-07-2021 |
Time |
20:23 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
07-07-2021 |
Time |
20:23 |
Sent To |
|
|
| Notes |
| 2021-07-07 20:26:45 | DEVELOPMENT SERVICES DEPARTMENT, BUILDING DIVISION, | | | COMMENTS: | | | | | | 1. THIS REVIEW IS A CURSORY REVIEW AS IT RELATES TO THE | | | SITE. IT IS NOT A REVIEW FOR FULL COMPLIANCE WITH | | | FLORIDA BUILDING CODE. THE FOLLOWING COMMENTS ARE TO BE | | | ADDRESSED FOR THE BUILDING PERMIT APPLICATION. | | | | | | 2. SEPARATE PERMITS REQUIRED. ALL APPLICABLE PERMITS | | | AND SUB-PERMITS MUST BE OBTAINED BEFORE COMMENCING THE | | | WORK. SEPARATE PERMITS, PLANS AND FEES, ARE REQUIRED | | | FOR SIGNS, GAS SYSTEMS, GENERATORS, FIRE ALARM SYSTEMS, | | | FIRE SPRINKLER AND OTHER FIRE SUPPRESSION SYSTEMS, | | | GREASE INTERCEPTORS, SITE LIGHTING, SITE LANDSCAPE, | | | SITE IRRIGATION, ETC. | | | | | | 3. BUILDING ADDRESS. EACH SEPARATE BUILDING, AND UNIT | | | WITH AN INDEPENDENT ENTRANCE FROM THE STREET, SHALL | | | HAVE A SEPARATE ADDRESS ASSIGNED BASED ON THE LOCATION | | | OF THE BUILDING ENTRANCE. FOR STREET ADDRESSING, | | | CONTACT CAROLINE PUELL, ADDRESSING COORDINATOR, AT | | | (561) 805 6659, OR BY EMAIL: [email protected] | | | | | | | | | ROBERT BROWN | | | BUILDING OFFICIAL | | | TEL: 561 805 6652 | | | EMAIL: [email protected] | | | |
|
|
| Review Stop |
ENG - PPRC |
ENGINEERING - PPRC |
| Rev No |
3 |
Status |
P |
Date |
08-12-2022 |
|
|
Cont ID |
|
| Sent By |
rrossano |
Date |
08-12-2022 |
Time |
|
Rev Time |
0.00 |
| Received By |
rrossano |
Date |
08-12-2022 |
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
ENG - PPRC |
ENGINEERING - PPRC |
| Rev No |
2 |
Status |
F |
Date |
10-26-2021 |
|
|
Cont ID |
|
| Sent By |
rrossano |
Date |
10-26-2021 |
Time |
|
Rev Time |
0.00 |
| Received By |
rrossano |
Date |
10-26-2021 |
Time |
|
Sent To |
|
|
| Notes |
| 2021-10-26 07:51:39 | COMMENTS FROM RICK ROSSANO, PROJECT COORDINATOR, ENG. | | | SERVICES DEPT., 561-494-1098 [email protected] : | | | 1. CHECK TO SEE IF FDEP FORMS FOR PROPOSED SANITARY | | | SEWER ARE REQUIRED. | | | 2. FOR FORMAL ENGINEERING SUBMITTAL , PLANS SHALL SHOW | | | PROPOSED LOCATIONS AND DIMENSIONS OF ALL WATER, | | | STORMWATER, AND SANITARY AND SEWER LINES, INCLUDING | | | STUBS TO EACH PROPERTY LINE FOR WATER AND SANITARY | | | SEWERS, THE MAKE AND MODEL OF ALL VALVES, METERS, AND | | | OTHERS DEVICES TO BE INSTALLED ON THE SYSTEM, CATCH | | | BASINS, CULVERTS, DITCHES INCLUDING GRADES, PIPES | | | SIZES, MATERIALS, ELEVATIONS, ASSUMPTIONS, | | | CALCULATIONS, INVERT ELEVATIONS FOR ALL INLETS AND | | | MANHOLES AND PROFILES OF SANITARY SEWER LINES. ALL | | | AVAILABLE ELEVATION SHALL BE SHOWN ON THE PROFILE VIEW. | | | DIRECTION OF FLOW SHALL BE SHOWN ON PLAN VIEW ON PLAN | | | VIEW FOR ALL SANITARY AND STORM SEWERS. ADDITIONALLY, | | | PLAN VIEW SHALL SHOW ALL EXISTING AND PROPOSED | | | UNDERGROUND UTILITY LAYOUT, INCLUDING FIBER OPTIC, | | | ELECTRIC, GAS, AND CABLEVISION & TELECOMMUNICATION | | | FACILITIES LOCATED ON THE RIGHT-OF-WAY. | | | 3. FOR FORMAL ENGINEERING SUBMITTAL , CUT AND CAP | | | UTILITIES NOT IN USE, AND REMOVE ANY ABANDONED UTILITY | | | LINES LARGER THAN 2 INCHES FROM CITY RIGHT OF WAY. | | | 4. FOR FORMAL ENGINEERING SUBMITTAL, SFWMD ERP AND | | | NPDES NOI REQUIREMENTS WILL BE ENFORCED. | | | - AN NOI IS REQUIRED FOR PROJECTS THAT: | | | - 1) DISTURB ONE OF MORE ACRES OF LAND OR DISTURB LESS | | | THAN ON ACRE OF LAND BUT ARE PART OF A COMMON PLAN OF | | | DEVELOPMENT OR SALE; AND | | | - 2) DISCHARGE STORMWATER TO SURFACE WATERS OF THE | | | STATE OR TO SURFACE WATERS OF THE STATE THROUGH A | | | MUNICIPAL SEPARATE STORM SEWER SYSTEM (MS4). | | | - THE SFWMD ERP CAN BE OBTAINED THROUGH A 10-2 SELF | | | CERTIFICATION THROUGH FDEP OR AN ERP APPLICATION | | | THROUGH SFWMD. EITHER WAY, THE DEVELOPER/ENGINEER SHALL | | | SUBMIT A COPY OF THE ERP PERMIT OR FDEP ACKNOWLEDGEMENT | | | OF THE 10-2 CERTIFICATION. IF THE ENGINEERING PLANS DO | | | NOT INCLUDE AN EROSION CONTROL PLAN, THEN THE | | | CONTRACTOR SHOULD SUBMIT ONE PRIOR TO RECEIVING THE | | | ENGINEERING PERMIT. | | | 5. FOR FORMAL ENGINEERING SUBMITTAL, PROVIDE PROFILES | | | OF PROPOSED AND EXISTING WATER AND SEWER WITHIN RIGHT | | | OF WAY AND SHOW ANY CROSSINGS/CONFLICTS. | | | 6. FOR FORMAL ENGINEERING SUBMITTAL, WHEN SUBMITTING | | | APPROVED MATERIALS LIST, PLEASE PROVIDE MATERIAL/CUT | | | SHEETS FOR ALL PROPOSED BACKFLOW DEVICES SHOWING | | | SPECIFIC MODEL NUMBER AND SPECIFYING USC APPROVED | | | LEAD-FREE DESIGN. | | | 7. FOR FORMAL ENGINEERING SUBMITTAL CLEARLY SHOW ROAD | | | RIGHT OF WAY. | | | 8. FOR FORMAL ENGINEERING SUBMITTAL, WHEN TRENCHING IN | | | IN CITY MAINTAINED ROADWAY AREAS ADD NOTE TO PROVIDE 50 | | | FT. PAVEMENT RESTORATION TRANSITION ON EACH SIDE OF | | | PROPOSED TRENCH PER CURRENT CITY OF WPB STANDARD DETAIL | | | GC-8. | | | 9. PLEASE RESPOND TO ALL COMMENTS IN WRITING AND | | | INCLUDE PROJECT NAME, ADDRESS AND PERMIT NUMBER | | | (Z-XXXXXXXX). | | | | | | COMMENTS FROM MARK HURLEY, FIELD CUSTOMER SERVICE | | | SUPER., WPB PUBLIC UTILITIES, 561-494-2262 OR | | | [email protected]: | | | -IF MAINTENANCE IS NEEDED ON LIFT STATION OR FORCE | | | MAIN, WHAT IS THE CONTACT INFORMATION FOR FPL (NAME, | | | PHONE, EMAIL)? | | | -WATER DEMAND DOCUMENT SAYS 92K GALLONS PEAK DAILY | | | IRRIGATION, BUT 30K GALLONS PER WEEK. PLEASE VERIFY | | | CALCULATIONS ARE CORRECT AT FORMAL ENGINEERING | | | SUBMITTAL. | | | -LIFT STATION REPORT SAYS IT WAS BASED ON 1840 FT OF 2 | | | INCH FM, BUT SOME SIZING WAS INCREASED TO 4 INCH. | | | PLEASE VERIFY LIFT STATION WILL STILL FUNCTION | | | PROPERLY. | | | -PLANS CALLOUT POSSIBLE RECLAIM VALVE IN ROAD. THERE IS | | | A LARGE RECLAIM WATER MAIN IN AREA. AT FORMAL | | | ENGINEERING SUBMITTAL, PLEASE LOOK AT THE RECLAIM | | | ASBUILTS AND SHOW ANY RECLAIM PIPING IN AREA. | | | -4 INCH FORCE MAIN CANNOT BE SCH80 PVC. PLEASE UPDATE | | | MATERIAL TYPE AT FORMAL ENGINEERING SUBMITTAL. | | | | | | COMMENTS FROM MICHAEL TECHNOW, PROJECT ENGINEER, WPB | | | PUBLIC UTILITIES, 561-494-1047, [email protected] : | | | -CALL OUT POINT OF SERVICE ON PLANS AS WELL AS DETAIL A | | | . | | | -SHOW FM AS ?PRIVATE? UNTIL CONNECTION WITH EXISTING | | | CITY SYSTEM. | | | -PROVIDE REFERENCE TO THE NEAREST MAJOR STREET/LANDMARK | | | IN DETAIL A. | | | -SHOW PROPOSED FM IN DETAIL A. | | | -ADD NOTE TO ENSURE THAT ANY ROADWAY OR CONSTRUCTION | | | RUNOFF IS INCLUDED IN THE MITIGATION PLAN. | | | -WHO OWNS THE EXISTING 32? RCP WM? (MATCH LINE C TO D) | | | -WHO OWNS THE EXISTING STORM PIPE? (MATCH LINE C TO D) | | | FEEL FREE TO CONTACT US IF YOU HAVE ANY QUESTIONS OR | | | CONCERNS, THANKS. | | | |
|
|
| Review Stop |
ENG - PPRC |
ENGINEERING - PPRC |
| Rev No |
1 |
Status |
F |
Date |
07-02-2021 |
|
|
Cont ID |
|
| Sent By |
rrossano |
Date |
07-02-2021 |
Time |
|
Rev Time |
|
| Received By |
rrossano |
Date |
07-02-2021 |
Time |
|
Sent To |
|
|
| Notes |
| 2021-07-02 12:17:15 | 1. THE CITY OF WEST PALM BEACH HAS A NUMBER OF | | | REGULATIONS AND PERMIT REQUIREMENTS WHICH DIRECTLY | | | AFFECT THE DEVELOPMENT AND INSTALLATION OF WATER AND | | | WASTEWATER UTILITIES WITHIN THE CITY. TO VIEW | | | DEVELOPMENT PERMIT SUBMITTAL REQUIREMENTS AND OTHER | | | ENGINEERING RELATED DOCUMENTS, CLICK HERE OR GO TO: HTT | | | PS://WWW.WPB.ORG/GOVERNMENT/ENGINEERING/ENGINEERING-FOR | | | MS-PERMITS-AND-APPLICATIONS . | | | 2. CODE OF ORDINANCES, CITY OF WEST PALM BEACH, | | | FLORIDA, CODIFIED THROUGH ORD. NO. 4183-08, ADOPTED | | | SEPT. 22, 2008. (SUPPLEMENT NO. 18) CHAPTER 90 | | | UTILITIES, ARTICLE I. SEC. 90-7. | | | POLICY REGARDING EXTENSION OF WATER OR SEWER SERVICE | | | FACILITIES OF THE CITY: | | | THE WATER AND WASTEWATER SERVICE AGREEMENTS AND THE | | | CONSTRUCTION PERMITS ADDRESS RESERVATION OF CAPACITY | | | BASED ON USAGE, METER SIZE AND FEES, DESIGN STANDARDS, | | | BACKFLOW PREVENTION, FIRE SERVICE AND IRRIGATION. | | | 3. AS OF DECEMBER 20, 2015, THE CITY OF WEST PALM BEACH | | | CROSS-CONNECTION CONTROL MANUAL HAS BEEN REVISED, | | | STATING "ALL BACKFLOW DEVICES MUST BE LEAD-FREE". FOR | | | MORE INFORMATION, CLICK HERE OR GO TO: HTTPS://WWW.WPB. | | | ORG/GOVERNMENT/ENGINEERING/ENGINEERING-FORMS-PERMITS-AN | | | D-APPLICATIONS . | | | 4. PLEASE SUBMIT A FORMAL AS-BUILT REQUEST FOR ALL CITY | | | OF WEST PALM BEACH-OWNED UTILITIES WITHIN THE PUBLIC | | | RIGHT OF WAY FOR THE ENTIRE EXTENT OF THE LIMITS OF | | | YOUR PROJECT. IDENTIFY TYPE OF UTILITY, LOCATION, PIPE | | | MATERIAL, AGE AND SIZE. PLEASE CONTACT JANICE TARBILL | | | IN THE WPB ENGINEERING SERVICES DEPARTMENT AT | | | [email protected] OR 561-494-1040 FOR FURTHER | | | ASSISTANCE. | | | 5. PLANS SHALL SHOW PROPOSED LOCATIONS AND DIMENSIONS | | | OF ALL WATER, STORMWATER, AND SANITARY AND SEWER LINES, | | | INCLUDING STUBS TO EACH PROPERTY LINE FOR WATER AND | | | SANITARY SEWERS, THE MAKE AND MODEL OF ALL VALVES, | | | METERS, AND OTHERS DEVICES TO BE INSTALLED ON THE | | | SYSTEM, CATCH BASINS, CULVERTS, DITCHES INCLUDING | | | GRADES, PIPES SIZES, MATERIALS, ELEVATIONS, | | | ASSUMPTIONS, CALCULATIONS, INVERT ELEVATIONS FOR ALL | | | INLETS AND MANHOLES AND PROFILES OF SANITARY SEWER | | | LINES. ALL AVAILABLE ELEVATION SHALL BE SHOWN ON THE | | | PROFILE VIEW. DIRECTION OF FLOW SHALL BE SHOWN ON PLAN | | | VIEW ON PLAN VIEW FOR ALL SANITARY AND STORM SEWERS. | | | PLEASE SHOW SLOPE % ON ALL SANITARY LINES AND CALL OUT | | | MATERIAL. ADDITIONALLY, PLAN VIEW SHALL SHOW ALL | | | EXISTING AND PROPOSED UNDERGROUND UTILITY LAYOUT, | | | INCLUDING FIBER OPTIC, ELECTRIC, GAS, AND CABLEVISION & | | | TELECOMMUNICATION FACILITIES LOCATED ON THE | | | RIGHT-OF-WAY. PROVIDE PROFILE AND CLEARANCES AT ALL | | | UTILITY CROSSINGS. | | | 6. CUT AND CAP UTILITIES NOT IN USE, AND REMOVE ANY | | | ABANDONED UTILITY LINES LARGER THAN 2 INCHES FROM CITY | | | ROW. | | | 7. PLEASE SUBMIT COMPLETED LOS ANALYSIS SUMMARY TABLE | | | DIRECTLY TO ENGINEERING (SHEET 33 OF CITY OF WPB | | | DEVELOPMENT APPLICATION). | | | 8. PROVIDE CALCULATIONS ON PLANS OF EXISTING AND | | | PROPOSED DEMANDS FOR WATER & SEWER (AVERAGE, MAXIMUM | | | AND PEAK) AND FIRE FLOW DEMANDS. CALCULATIONS SHALL BE | | | PER FAC 64E-8 FOR WATER AND PER FAC 64-E.008 FOR SEWER. | | | 9. SHOW VERTICAL DATUM AND DATUM CONVERSION INFORMATION | | | (NAVD 88 AND NGVD 29). | | | 10. PLEASE ADD NOTE TO PLANS SPECIFYING CITY?S | | | DOWNSTREAM LIFT STATION NUMBER. | | | 11. PLEASE PROVIDE CALCULATIONS OF REVISED PERVIOUS AND | | | IMPERVIOUS CALCULATIONS FOR THE PROPOSED IMPACTED | | | AREAS. | | | 12. PLEASE LABEL WATER LINES AS PRIVATE WHERE | | | APPLICABLE. | | | 13. ON SHEET EKRA-02 1 OF 2 AND 2 OF 2, THERE IS A 2? | | | PROPOSED FM. THE DETAIL SHOWS A PROPOSED 4? FM | | | CONNECTING TO AN EXISTING 16? DIP FM. CLARIFY IF 2? OR | | | 4?. | | | 14. ON SHEET EKRA-02 1 OF 2 AND 2 OF 2, PLEASE LABEL | | | LENGTH AND SIZE OF PROPOSED FM. | | | 15. ON ALL UTILITY PLAN SHEETS, PLEASE LABEL ?PROPOSED? | | | OR ?EXISTING? FOR ALL WATER AND SEWER UTILITIES. | | | | | | THE FOLLOWING COMMENTS ARE FROM MARK HURLEY, FIELD | | | CUSTOMER SERVICE SUPERVISOR, WPB PUBLIC UTILITIES, | | | PLEASE CONTACT 561-494-2262 OR [email protected]: | | | | | | -VERIFY FPL WILL OWN AND MAINTAIN THE ENTIRETY OF THE | | | PROPOSED 2 INCH FORCE MAIN. | | | -SHOW AND LABEL WELL AND LIFT STATION ON SITE PLAN. | | | -FPL MUST COMPLY WITH WPB UTILITY BILLING REQUIREMENTS | | | FOR WASTEWATER. | | | -WILL WELL BE USED FOR IRRIGATION AND ALSO FOR POTABLE | | | WATER ON SITE? | | | | | | FEEL FREE TO CONTACT US IF YOU HAVE ANY QUESTIONS OR | | | CONCERNS, THANKS. | | | RICK ROSSANO, PROJECT COORDINATOR, ENGINEERING | | | SERVICES, (561) 494-1098 [email protected] | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
10-15-2021 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
10-15-2021 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
10-15-2021 |
Time |
15:03 |
Sent To |
|
|
| Notes |
| 2021-10-15 15:06:02 | REVIEWED AND APPROVED BY FIRE PREVENTION. | | | | | | THIS MAY NOT REPRESENT FIRE'S FINAL REVIEW AND APPROVAL | | | AS ANY FUTURE SUBMITTALS WILL BE REVIEWED AS | | | APPLICABLE. | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | [email protected] | | | 561-312-1021 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
07-06-2021 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
07-06-2021 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
07-06-2021 |
Time |
10:31 |
Sent To |
|
|
| Notes |
| 2021-07-06 10:53:19 | FIRE HAS NO OBJECTIONS TO THE PROPOSED; HOEVER, THE | | | FOLLOWING COMMENTS REQUIRE ATTENTIONAND CORRECTION. | | | | | | FIRE'S REVIEW OF THIS SUBMITTED PROJECT DOES NOT | | | CONSTITUTE IT'S FINAL REVIEW. | | | | | | | | | 1. THERE IS AN INDICATION OF A TURNAROUND WITH A 75' | | | DDIMENSION. | | | | | | A TURNAROUND IS REQUIRED; HOWEVER, THE MIN. DIMESION IS | | | 96' WITH A 28' RADIUS. | | | | | | PLEASE REVIEW AND CORRECT. | | | | | | | | | 2. THERE ARE INDICATIONS OF GATE ENTRANCE/EGRESS, | | | | | | IT IS RECOMMENDED, NOR REQUIRED, FOR EMERGENCY ACCESS | | | AND SITE SECURITY, THAT IF THE GATE IS ELECTRONIC OPEN, | | | A KNOX KEYSWITCH BE PROVIDED. FOR CHAIN AND LOCK GATE | | | SECURITY THAT A KNOX PADLOCK BE PROVIDED. | | | | | | IN THE EVENT OF AN EMERGENCY INCIDENT, FIRE CREWS WILL | | | NOT BE ABLE TO RELOCK/SECURE A BREECHED ELECTRIC GATE | | | NOR A CUT CHAIN OR LOCK. | | | | | | PLEASE PROVIDE A NOTE OF ACKNOWLEDGEMENT OR THAT | | | NIETHER WILL BE PROVIDED. | | | | | | | | | 3. FIRE SHALL REVIEW ALL SUBMITTED BUILDING PLANS, IF | | | APPLICABLE, AT THE APPROPRIATE TIME AND IN ACCORDANCE | | | WITH THE REQUIREMENTS OF ALL APPLICABLE CODES AND | | | STANDARDS. | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
4 |
Status |
P |
Date |
09-27-2022 |
|
|
Cont ID |
|
| Sent By |
rcaranci |
Date |
09-27-2022 |
Time |
14:03 |
Rev Time |
0.00 |
| Received By |
rcaranci |
Date |
09-27-2022 |
Time |
14:02 |
Sent To |
|
|
| Notes |
| 2022-09-27 14:03:28 | FROM: RAY CARANCI, SENIOR LANDSCAPE PLANNER | | | 561-822-1462 | | | PROJECT: 47TH PL N FPL SUBSTATION ISPR 21-08 Z21050030 | | | SEPTEMBER 27, 2022 | | | I HAVE REVIEWED THE ABOVE REFERENCED PETITION, AND | | | PROVIDE THE FOLLOWING COMMENTS: | | | | | | | | | 1. SATISFIED. ON TREE SURVEY THE TREE DISPOSITION CHART | | | COULD NOT BE FOUND. A DETAILED LIST DESCRIBING SPECIES | | | , CONDITION AND DIAMETER BREAST HEIGHT FOR EACH TREE | | | PROPOSED TO BE REMOVED OR RELOCATED. | | | A. THE SURVEY SHOWS TREES MARKED WITH SYMBOLS FOR PINE | | | TREE WITHIN THE ACCESS EASEMENT AREA AND PROPOSED AREA | | | OF INITIAL CLEARING. ALL TREES NEED TO BE IDENTIFIED ON | | | A TREE DISPOSITION PLAN AND LIST FOR THE ENTIRE | | | EASEMENT AREA. | | | B. THE EASEMENT AGREEMENT SHOULD BE AMENDED TO INDICATE | | | HOW FUTURE TREE REMOVALS AND CLEARING SHALL BE | | | PERMITTED IF IT IS NOT ALL GOING TO HAPPEN WITH THE | | | INITIAL SUBSTATION CONSTRUCTION AND PERMITTING. | | | C. REMOVAL OR TRIMMING OF AUSTRALIAN PINES ALONG THE | | | ACCESS ROAD THAT IS PROPOSED TO BE PAVED AT 20 FEET | | | WIDE SHOULD ALSO BE INDICATED ON THE TREE DISPOSITION | | | PLAN. | | | D. THE CITY WOULD REQUEST TO HAVE ALL INVASIVE EXOTICS | | | REMOVED WITHIN THE EASEMENT AREA PER SECTION | | | 94-448(F)(11) AND CITY POLICY 10-2. INVASIVE EXOTIC | | | SPECIES NEED TO BE IDENTIFIED AND A REMOVAL PLAN MUST | | | BE SUBMITTED AT THIS TIME. | | | | | | | | | 2. SATISFIED. NATIVE TREES AND PALMS IN GOOD CONDITION | | | MUST BE PRESERVED ON SITE OR RELOCATED. 94-448 3. | | | INVESTIGATING IF MITIGATION OPTIONS ARE ABLE TO BE | | | COMBINED WITH PUBLIC UTILITIES WETLAND MITIGATION. | | | (ANDREW BURNETT 561-822-1562 REVIEW 7/8/21 FPL KRAKEN | | | PLAN #Z21050030) | | | | | | SLASH PINES CANNOT BE RELOCATED SO WOULD BE ANTICIPATED | | | TO REQUIRE MITIGATION. | | | SABAL PALMS WOULD BE RELOCATED. MITIGATION AND | | | RELOCATION CAN BE PROVIDED ANYWHERE WITHIN THE CITY | | | OWNED PARCEL AND MAY BE COMBINED AS PART OF WETLAND | | | MITIGATION. | | | | | | 8/12/22 THE 23 SABAL PALMS SHOWN IN GOOD CONDITION MUST | | | BE RELOCATED. | | | SHOW AS RELOCATES INSTEAD OF REMOVAL AND SHOW FINAL | | | LOCATIONS ON THE LANDSCAPE PLAN AND INCLUDE ON THE | | | PLANT LIST. THIS LESSENS THE MITIGATION BY 2400 SQ FT. | | | IF THERE IS ANOTHER REASON FOR REMOVAL, PLEASE PROVIDE | | | IT. | | | | | | | | | | | | | | | TOTAL MITIGATION DUE 14,116 + 4,226 = 18,342 SQ FT. | | | | | | WITHOUT THE SABAL PALMS, AND IF NO MITIGATION TREES ARE | | | BEING PROVIDED, THE PAYMENT IN LIEU OPTION WOULD BE | | | $30, 570.00 | | | | | | | | | TOTAL MITIGATION DUE 14,916 SQ FT | | | | | | | | | CONDITIONS OF APPROVAL | | | 1. PRIOR TO THE REMOVAL OR RELOCATION OF ANY TREES ON | | | THE PROPERTY, A TREE ALTERATION PERMIT SHALL BE | | | SUBMITTED, REVIEWED AND APPROVED BY THE DEVELOPMENT | | | SERVICES DEPARTMENT, PLANNING DIVISION. | | | |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
3 |
Status |
F |
Date |
08-12-2022 |
|
|
Cont ID |
|
| Sent By |
rcaranci |
Date |
08-12-2022 |
Time |
15:35 |
Rev Time |
0.00 |
| Received By |
rcaranci |
Date |
08-12-2022 |
Time |
15:35 |
Sent To |
|
|
| Notes |
| 2022-08-12 15:36:23 | FROM: RAY CARANCI, SENIOR LANDSCAPE PLANNER | | | 561-822-1462 | | | PROJECT: 47TH PL N FPL SUBSTATION ISPR 21-08 Z21050030 | | | AUGUST 12, 2022 | | | I HAVE REVIEWED THE ABOVE REFERENCED PETITION, AND | | | PROVIDE THE FOLLOWING COMMENTS: | | | | | | | | | 1. SATISFIED. ON TREE SURVEY THE TREE DISPOSITION CHART | | | COULD NOT BE FOUND. A DETAILED LIST DESCRIBING SPECIES | | | , CONDITION AND DIAMETER BREAST HEIGHT FOR EACH TREE | | | PROPOSED TO BE REMOVED OR RELOCATED. | | | A. THE SURVEY SHOWS TREES MARKED WITH SYMBOLS FOR PINE | | | TREE WITHIN THE ACCESS EASEMENT AREA AND PROPOSED AREA | | | OF INITIAL CLEARING. ALL TREES NEED TO BE IDENTIFIED ON | | | A TREE DISPOSITION PLAN AND LIST FOR THE ENTIRE | | | EASEMENT AREA. | | | B. THE EASEMENT AGREEMENT SHOULD BE AMENDED TO INDICATE | | | HOW FUTURE TREE REMOVALS AND CLEARING SHALL BE | | | PERMITTED IF IT IS NOT ALL GOING TO HAPPEN WITH THE | | | INITIAL SUBSTATION CONSTRUCTION AND PERMITTING. | | | C. REMOVAL OR TRIMMING OF AUSTRALIAN PINES ALONG THE | | | ACCESS ROAD THAT IS PROPOSED TO BE PAVED AT 20 FEET | | | WIDE SHOULD ALSO BE INDICATED ON THE TREE DISPOSITION | | | PLAN. | | | D. THE CITY WOULD REQUEST TO HAVE ALL INVASIVE EXOTICS | | | REMOVED WITHIN THE EASEMENT AREA PER SECTION | | | 94-448(F)(11) AND CITY POLICY 10-2. INVASIVE EXOTIC | | | SPECIES NEED TO BE IDENTIFIED AND A REMOVAL PLAN MUST | | | BE SUBMITTED AT THIS TIME. | | | | | | | | | 2. PARTIALLY SATISFIED. NATIVE TREES AND PALMS IN GOOD | | | CONDITION MUST BE PRESERVED ON SITE OR RELOCATED. | | | 94-448 3. INVESTIGATING IF MITIGATION OPTIONS ARE ABLE | | | TO BE COMBINED WITH PUBLIC UTILITIES WETLAND | | | MITIGATION. | | | (ANDREW BURNETT 561-822-1562 REVIEW 7/8/21 FPL KRAKEN | | | PLAN #Z21050030) | | | | | | SLASH PINES CANNOT BE RELOCATED SO WOULD BE ANTICIPATED | | | TO REQUIRE MITIGATION. | | | SABAL PALMS WOULD BE RELOCATED. MITIGATION AND | | | RELOCATION CAN BE PROVIDED ANYWHERE WITHIN THE CITY | | | OWNED PARCEL AND MAY BE COMBINED AS PART OF WETLAND | | | MITIGATION. | | | | | | 8/12/22 THE 23 SABAL PALMS SHOWN IN GOOD CONDITION MUST | | | BE RELOCATED. | | | SHOW AS RELOCATES INSTEAD OF REMOVAL AND SHOW FINAL | | | LOCATIONS ON THE LANDSCAPE PLAN AND INCLUDE ON THE | | | PLANT LIST. THIS LESSENS THE MITIGATION BY 2400 SQ FT. | | | IF THERE IS ANOTHER REASON FOR REMOVAL, PLEASE PROVIDE | | | IT. | | | | | | | | | | | | | | | TOTAL MITIGATION DUE 14,116 + 4,226 = 18,342 SQ FT. | | | | | | WITHOUT THE SABAL PALMS, AND IF NO MITIGATION TREES ARE | | | BEING PROVIDED, THE PAYMENT IN LIEU OPTION WOULD BE | | | $30, 570.00 | | | | | | | | | | | | | | | | | | CONDITIONS OF APPROVAL | | | 1. PRIOR TO THE REMOVAL OR RELOCATION OF ANY TREES ON | | | THE PROPERTY, A TREE ALTERATION PERMIT SHALL BE | | | SUBMITTED, REVIEWED AND APPROVED BY THE DEVELOPMENT | | | SERVICES DEPARTMENT, PLANNING DIVISION. | | | |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
2 |
Status |
F |
Date |
10-22-2021 |
|
|
Cont ID |
|
| Sent By |
rcaranci |
Date |
10-22-2021 |
Time |
10:18 |
Rev Time |
0.00 |
| Received By |
rcaranci |
Date |
10-22-2021 |
Time |
10:18 |
Sent To |
|
|
| Notes |
| 2021-10-22 10:19:42 | FROM: RAY CARANCI, SENIOR LANDSCAPE PLANNER | | | 561-822-1462 | | | PROJECT: 47TH PL N FPL SUBSTATION ISPR 21-08 Z21050030 | | | OCTOBER 19, 2021 | | | I HAVE REVIEWED THE ABOVE REFERENCED PETITION, AND | | | PROVIDE THE FOLLOWING COMMENTS: | | | | | | | | | 1. NOT SATISFIED. ON TREE SURVEY THE TREE DISPOSITION | | | CHART COULD NOT BE FOUND. A DETAILED LIST DESCRIBING | | | SPECIES , CONDITION AND DIAMETER BREAST HEIGHT FOR EACH | | | TREE PROPOSED TO BE REMOVED OR RELOCATED. | | | THE SURVEY SHOWS TREES MARKED WITH SYMBOLS FOR PINE | | | TREE WITHIN THE ACCESS EASEMENT AREA AND PROPOSED AREA | | | OF INITIAL CLEARING. ALL TREES NEED TO BE IDENTIFIED ON | | | A TREE DISPOSITION PLAN AND LIST FOR THE ENTIRE | | | EASEMENT AREA. THE EASEMENT AGREEMENT SHOULD BE AMENDED | | | TO INDICATE HOW FUTURE TREE REMOVALS AND CLEARING SHALL | | | BE PERMITTED IF IT IS NOT ALL GOING TO HAPPEN WITH THE | | | INITIAL SUBSTATION CONSTRUCTION AND PERMITTING. | | | REMOVAL OR TRIMMING OF AUSTRALIAN PINES ALONG THE | | | ACCESS ROAD THAT IS PROPOSED TO BE PAVED AT 20 FEET | | | WIDE SHOULD ALSO BE INDICATED ON THE TREE DISPOSITION | | | PLAN. | | | THE CITY WOULD REQUEST TO HAVE ALL INVASIVE EXOTICS | | | REMOVED WITHIN THE EASEMENT AREA PER SECTION | | | 94-448(F)(11) AND CITY POLICY 10-2. INVASIVE EXOTIC | | | SPECIES NEED TO BE IDENTIFIED AND A REMOVAL PLAN MUST | | | BE SUBMITTED AT THIS TIME. | | | | | | | | | 2. NOT SATISFIED. NATIVE TREES AND PALMS IN GOOD | | | CONDITION MUST BE PRESERVED ON SITE OR RELOCATED. | | | 94-448 3. INVESTIGATING IF MITIGATION OPTIONS ARE ABLE | | | TO BE COMBINED WITH PUBLIC UTILITIES WETLAND | | | MITIGATION. | | | SLASH PINES CANNOT BE RELOCATED SO WOULD BE ANTICIPATED | | | TO REQUIRE MITIGATION. | | | SABAL PALMS WOULD BE RELOCATED. MITIGATION AND | | | RELOCATION CAN BE PROVIDED ANYWHERE WITHIN THE CITY | | | OWNED PARCEL AND MAY BE COMBINED AS PART OF WETLAND | | | MITIGATION. | | | | | | (ANDREW BURNETT 561-822-1562 REVIEW 7/8/21 FPL KRAKEN | | | PLAN #Z21050030) | | | | | | | | | | | | | | | CONDITIONS OF APPROVAL | | | 1. PRIOR TO THE REMOVAL OR RELOCATION OF ANY TREES ON | | | THE PROPERTY, A TREE ALTERATION PERMIT SHALL BE | | | SUBMITTED, REVIEWED AND APPROVED BY THE DEVELOPMENT | | | SERVICES DEPARTMENT, PLANNING DIVISION. | | | |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
1 |
Status |
F |
Date |
07-06-2021 |
|
|
Cont ID |
|
| Sent By |
aburnett |
Date |
07-06-2021 |
Time |
16:02 |
Rev Time |
0.00 |
| Received By |
aburnett |
Date |
07-06-2021 |
Time |
16:01 |
Sent To |
|
|
| Notes |
| 2021-07-06 16:02:44 | ANDREW BURNETT | | | 561-822-1562 | | | REVIEW 7/8/21 | | | FPL KRAKEN PLAN #Z21050030 | | | | | | 1. ON TREE SURVEY THE TREE DISPOSITION CHART COULD NOT | | | BE FOUND. A DETAILED LIST DESCRIBING SPECIES , | | | CONDITION AND DIAMETER BREAST HEIGHT FOR EACH TREE | | | PROPOSED TO BE REMOVED OR RELOCATED. | | | | | | 2. NATIVE TREES AND PALMS IN GOOD CONDITION MUST BE | | | PRESERVED ON SITE OR RELOCATED. 94-448 3. INVESTIGATING | | | IF MITIGATION OPTIONS ARE ABLE TO BE COMBINED WITH | | | PUBLIC UTILITIES WETLAND MITIGATION. . | | | | | | | | | | | | | | | |
|
|
| Review Stop |
PU |
PUBLIC UTILITIES |
| Rev No |
1 |
Status |
P |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
| Received By |
mtechnow |
Date |
08-23-2022 |
Time |
11:49 |
Sent To |
|
|
| Notes |
| 2022-08-23 11:56:47 | FOR ENGINEERING SUBMITTAL: PLEASE NOTE COVER AS 36" ON | | | FM PROFILE. THERE IS A DISCREPANCY ON THE CALL OUTS. |
|
|
| Review Stop |
PU-CS |
PUBLIC UTILITIES CUSTOMER SRVC |
| Rev No |
1 |
Status |
P |
Date |
08-05-2022 |
|
|
Cont ID |
|
| Sent By |
mhurley |
Date |
08-05-2022 |
Time |
15:52 |
Rev Time |
0.00 |
| Received By |
mhurley |
Date |
08-05-2022 |
Time |
15:50 |
Sent To |
|
|
| Notes |
| 2022-08-05 15:51:49 | NO FURTHER REVIEW COMMENTS UNTIL ENGINEERING | | | DEVELOPMENT SUBMITTAL. |
|
|
| Review Stop |
PW |
PUBLIC WORKS |
| Rev No |
1 |
Status |
P |
Date |
06-24-2021 |
|
|
Cont ID |
|
| Sent By |
|
Date |
06-24-2021 |
Time |
|
Rev Time |
|
| Received By |
|
Date |
06-24-2021 |
Time |
|
Sent To |
|
|
| Notes |
| 2021-06-24 12:57:05 | NO OBJECTION FROM PUBLIC WORKS. | | | | | | MATT HEJAZI | | | DEPT. OF PUBLIC WORKS | | | [email protected] | | | 561-822-2045 |
|
|
| Review Stop |
STORM |
STORMWATER |
| Rev No |
4 |
Status |
P |
Date |
09-30-2022 |
|
|
Cont ID |
|
| Sent By |
tward |
Date |
09-30-2022 |
Time |
10:04 |
Rev Time |
0.00 |
| Received By |
tward |
Date |
09-30-2022 |
Time |
10:05 |
Sent To |
|
|
| Notes |
| 2022-09-30 10:05:47 | NO COMMENTS ON THE 9/14/2022 SUBMITTAL. |
|
|
| Review Stop |
STORM |
STORMWATER |
| Rev No |
3 |
Status |
P |
Date |
08-23-2022 |
|
|
Cont ID |
|
| Sent By |
tward |
Date |
08-23-2022 |
Time |
09:50 |
Rev Time |
0.00 |
| Received By |
tward |
Date |
08-23-2022 |
Time |
10:00 |
Sent To |
|
|
| Notes |
| 2022-08-23 09:59:11 | THE FOLLOWING COMMENTS ARE FROM THE REVIEW OF THE | | | 7/26/2022 SUBMITTAL. THEY CAN BE ADDRESSED WITH THE | | | ENGINEERING PERMIT SUBMITTAL. | | | | | | 1. CROSS SECTIONS REFERENCE PAGES NEED TO BE UPDATED | | | FROM "2 OF 5" TO "3 OF 7". | | | | | | 2. LIST THE VERTICAL DATUM AND CONVERSION TO NGVD1929 | | | ON SHEETS 1 OF 2 AND 2 OF 2 (E-KRA01J). THERE IS A | | | STANDING WATER ELEVATION LISTED ON THE PAGES. | | | | | | TRACY WARD, PE | | | SENIOR STORMWATER ENGINEER | | | ENGINEERING SERVICES DEPARTMENT | | | 561-494-1120 (O) | | | 561-351-0510 (M) | | | [email protected] | | | | | | |
|
|
| Review Stop |
STORM |
STORMWATER |
| Rev No |
2 |
Status |
F |
Date |
12-07-2021 |
|
|
Cont ID |
|
| Sent By |
tward |
Date |
12-07-2021 |
Time |
14:04 |
Rev Time |
0.00 |
| Received By |
tward |
Date |
12-07-2021 |
Time |
16:34 |
Sent To |
|
|
| Notes |
| 2021-12-07 16:34:33 | THE FOLLOWING COMMENTS ARE FROM THE REVIEW OF THE | | | 10/14/2021 SUBMITTAL: | | | | | | | | | 1. [SATISFIED] ON THE OVERALL SITE PLAN (SHEET 1 OF 2), | | | SHOULD THE LABEL 'EGRET LAKE ELEMENTARY' ABOVE STA22+00 | | | BE MOVED TO ABOVE STA41+00? | | | | | | 2. [NOT SATISFIED] EVERY SHEET WITH ELEVATION | | | INFORMATION WILL NEED THE VERTICAL DATUM LISTED ALONG | | | WITH THE CONVERSION EQUATION TO NGVD1929. {PREVIOUS | | | COMMENT: THE CITY'S OFFICIAL VERTICAL DATUM PER CITY | | | CODE IS NGVD1929. THE CITY IS ALLOWING SURVEYS AND | | | PLANS TO USE NAVD1988 PROVIDED THE CONVERSION EQUATION | | | BETWEEN NAVD1988 AND NGVD1929 IS ALSO PROVIDED. LABEL | | | THE VERTICAL DATUM AND CONVERSION EQUATION TO NGVD1929 | | | ON ALL CIVIL ENGINEERING SHEETS WITH ELEVATION | | | INFORMATION.} | | | | | | 3. [SATISFIED] FOR SECTION A-A ON SHEET 3 OF 7, | | | CONSIDER CHANGING THE NOTE 'ALL SLOPES GREATER THAN 5:1 | | | TO BE SODDED' TO 'ALL SLOPES FLATTER THAN 5:1 TO BE | | | SODDED' (OR STEEPER DEPENDING ON THE INTENT OF THE | | | NOTE). | | | | | | 4. [SATISFIED FOR NOW. DRAINAGE CALCULATIONS WILL BE | | | REVIEWED WITH THE ENGINEERING PERMIT SUBMITTAL.] THE | | | BOTTOM ELEVATION OF THE ROADSIDE SWALES VARY BETWEEN | | | 13.5 AND 15.8 ALONG THE ROAD. WAS THIS VARIATION | | | CONSIDERED IN THE SWALE STORAGE VOLUME FOR WATER | | | QUALITY TREATMENT? WILL THERE BE DITCH BLOCKS | | | CONSTRUCTED TO MAXIMIZE THE STORAGE IN THE SWALE? THE | | | DRAINAGE CALCULATIONS WILL BE REVIEWED AT ENGINEERING | | | PERMIT SUBMITTAL. | | | | | | 5. [PARTIALLY SATISFIED] REVIEW THE DISCHARGE LOCATION | | | FOR THE SWALES EAST OF THE EXISTING FENCE/GATE CROSSING | | | THE R/W AT APPROXIMATE STA39+00. THERE ARE PRIVATE | | | PARCELS (SOME DEVELOPED) ADJACENT TO THE R/W. {PREVIOUS | | | COMMENT: HOW AND WHERE WILL THE ROADSIDE SWALES | | | DISCHARGE? THERE APPEARS TO BE A BERM ALONG THE NORTH | | | SIDE OF THE EXISTING DITCH EAST OF STA11+00. WILL THE | | | TOP OF THE BERM BE AFFECTED WITH THE ROAD | | | CONSTRUCTION?} | | | | | | 6. [SATISFIED - THIS PIPE IS THE RESPONSIBILTY OF THE | | | SCHOOL DISTRICT.] PROVIDE CONDITION ASSESSMENT OF THE | | | STORM PIPE(S) CROSSED BY THE PROPOSED ROAD (APPROX. | | | STA39+00). | | | | | | 7. [PARTIALLY SATISFIED] WEIR ELEVATION OF NEW CONTROL | | | STRUCTURE (IN THE DETENTION AREA) IS 19.50 FEET NAVD. | | | THE DIMENSIONS IN THE EXFILTRATION TRENCH DETAIL WILL | | | PROVIDE TOP OF TRENCH ELEVATIONS BETWEEN 19.70 FEET | | | NAVD AND 20.10 FT NAVD, WHICH IS HIGHER THAN THE WEIR | | | ELEVATION AND THE EXFILTRATION TRENCH WILL NOT BE FULLY | | | SURCHARGED. {PREVIOUS COMMENT: CHECK THE ELEVATIONS | | | LISTED FOR THE FRENCH DRAIN DETAIL ON SHEET 3 OF 7 AND | | | THE DRAINAGE CONTROL STRUCTURE DSC-1 DETAIL ON SHEET 4 | | | OF 7.} | | | | | | 8. [SATISFIED - MAY WANT TO CONSIDER CRUSHED CONCRETE | | | AS ROAD BASE MATERIAL IN ADDITION TO SOIL CEMENT] | | | LIMEROCK MAY NOT BE SUITABLE FOR THE ROAD BASE IF IT | | | WILL BE SUSCEPTIBLE TO SATURATION FROM THE HIGH GROUND | | | WATER TABLE AND/OR SWALE STORAGE. | | | | | | NEW COMMENTS (THESE MAYBE ADDRESSED DURING ENGINEERING | | | PERMIT SUBMITTAL); | | | 9. CONSIDER PLACING GEOTEXTILE (SOILED FILLED CELLS, | | | ETC.) ACROSS THE WEIR AND THE OUTSIDE SLOPE OF THE | | | DETENTION AREA TO PROTECT AGAINST EROSION. | | | | | | 10. NOTE 3 ON SHEET 1 OF 2 FOR THE SEWER LIFT STATION | | | LISTS THE SEASONAL HIGH WATER TABLE ELEVATION AS 0.0' | | | NAVD. | | | | | | 11. SHEET 1 OF 7 (FENCE FILL AND GRADE PLAN SHEET) | | | LISTS THE FFE ELEVATION OF THE RELAY VAULT AS 22.17 FT | | | NAVD. THE SECTION THRU SEPTIC TANK SYSTEM DETAIL ON | | | SHEET 1 OF 2 (WATER LINE CONNECTION AND SEWER LIFT | | | STATION DETAILS SHEET) CALLS OUT MIN. 1% SLOPE FOR THE | | | 4" LATERAL. | | | | | | 12. SHEET 1 OF 7 (FENCE FILL AND GRADE PLAN SHEET) | | | CALLS OUT MIN. 2% SLOPE (1/4 INCH PER FOOT) FOR THE | | | 4-INCH SEWER LATERAL.. THE SECTION THRU SEPTIC TANK | | | SYSTEM DETAIL ON SHEET 1 OF 2 (WATER LINE CONNECTION | | | AND SEWER LIFT STATION DETAILS SHEET) CALLS OUT THE | | | FINISHED LFOOR ELEVATION OF 21.70 FT NAVD FOR THE | | | SUBSTATION RELAY VAULT. | | | | | | TRACY WARD, PE | | | SENIOR STORMWATER ENGINEER | | | ENGINEERING SERVICES DEPARTMENT | | | 561-494-1120 (O) | | | 561-351-0510 (M) | | | [email protected] | | | |
|
|
| Review Stop |
STORM |
STORMWATER |
| Rev No |
1 |
Status |
F |
Date |
07-08-2021 |
|
|
Cont ID |
|
| Sent By |
tward |
Date |
07-08-2021 |
Time |
10:39 |
Rev Time |
0.00 |
| Received By |
tward |
Date |
07-08-2021 |
Time |
10:39 |
Sent To |
|
|
| Notes |
| 2021-07-08 10:39:30 | THIS IS A CONCEPTUAL LEVEL REVIEW. CONSTRUCTION LEVEL | | | DETAILS, DESIGN CALCULATIONS AND THE POLLUTION | | | PREVENTION PLAN WILL BE REVIEWED AS PART OF THE | | | ENGINEERING DEVELOPMENT APPROVAL AND BUILDING PERMIT | | | APPLICATION PROCESSES. | | | | | | THE FOLLOWING COMMENTS MUST BE ADDRESSED PRIOR TO SITE | | | PLAN APPROVAL: | | | | | | 1. ON THE OVERALL SITE PLAN (SHEET 1 OF 2), SHOULD THE | | | LABEL ?EGRET LAKE ELEMENTARY? ABOVE STA22+00 BE MOVED | | | TO ABOVE STA41+00? | | | | | | 2. THE CITY?S OFFICIAL VERTICAL DATUM PER CITY CODE IS | | | NGVD1929. THE CITY IS ALLOWING SURVEYS AND PLANS TO USE | | | NAVD1988 PROVIDED THE CONVERSION EQUATION BETWEEN | | | NAVD1988 AND NGVD1929 IS ALSO PROVIDED. LABEL THE | | | VERTICAL DATUM AND CONVERSION EQUATION TO NGVD1929 ON | | | ALL CIVIL ENGINEERING SHEETS WITH ELEVATION | | | INFORMATION. | | | | | | 3. FOR SECTION A-A ON SHEET 3 OF 7, CONSIDER CHANGING | | | THE NOTE ?ALL SLOPES GREATER THAN 5:1 TO BE SODDED? TO | | | ?ALL SLOPES FLATTER THAN 5:1 TO BE SODDED? (OR STEEPER | | | DEPENDING ON THE INTENT OF THE NOTE). | | | | | | 4. THE BOTTOM ELEVATION OF THE ROADSIDE SWALES VARY | | | BETWEEN 13.5 AND 15.8 ALONG THE ROAD. WAS THIS | | | VARIATION CONSIDERED IN THE SWALE STORAGE VOLUME FOR | | | WATER QUALITY TREATMENT? WILL THERE BE DITCH BLOCKS | | | CONSTRUCTED TO MAXIMIZE THE STORAGE IN THE SWALE? THE | | | DRAINAGE CALCULATIONS WILL BE REVIEWED AT ENGINEERING | | | PERMIT SUBMITTAL. | | | | | | 5. HOW AND WHERE WILL THE ROADSIDE SWALES DISCHARGE? | | | THERE APPEARS TO BE A BERM ALONG THE NORTH SIDE OF THE | | | EXISTING DITCH EAST OF STA11+00. WILL THE TOP OF THE | | | BERM BE AFFECTED WITH THE ROAD CONSTRUCTION? | | | | | | 6. PROVIDE CONDITION ASSESSMENT OF THE STORM PIPE(S) | | | CROSSED BY THE PROPOSED ROAD (APPROX. STA39+00). | | | | | | 7. CHECK THE ELEVATIONS LISTED FOR THE FRENCH DRAIN | | | DETAIL ON SHEET 3 OF 7 AND THE DRAINAGE CONTROL | | | STRUCTURE DSC-1 DETAIL ON SHEET 4 OF 7. | | | | | | 8. LIMEROCK MAY NOT BE SUITABLE FOR THE ROAD BASE IF IT | | | WILL BE SUSCEPTIBLE TO SATURATION FROM THE HIGH GROUND | | | WATER TABLE AND/OR SWALE STORAGE. | | | | | | | | | THE FOLLOWING COMMENTS MUST BE ADDRESSED PRIOR TO | | | ISSUANCE OF CONSTRUCTION AUTHORIZATION INCLUDING | | | BUILDING PERMITS AND ENGINEERING DEVELOPMENT APPROVAL. | | | | | | 1. AN ENGINEERING DEVELOPMENT APPROVAL APPLICATION MAY | | | BE REQUIRED FROM THE ENGINEERING SERVICES DEPARTMENT. | | | | | | 2. EROSION CONTROL PLAN AND DETAILS TO BE SUBMITTED | | | WITH THE ENGINEERING PERMIT APPLICATION. | | | | | | 3. PROVIDE COPY OF SFWMD ERP PERMIT(S) BEFORE START OF | | | CONSTRUCTION. | | | | | | 4. THE PROJECT IS WITHIN THE NORTHERN PALM BEACH COUNTY | | | IMPROVEMENT DISTRICT. PROVIDE A COPY OF THE NPBCID | | | PERMIT BEFORE THE START OF CONSTRUCTION. | | | | | | 5. PROVIDE A COPY OF THE DRAINAGE CALCULATIONS WITH THE | | | ENGINEERING PERMIT APPLICATION. | | | | | | TRACY WARD, PE | | | SENIOR STORMWATER ENGINEER | | | ENGINEERING SERVICES DEPARTMENT | | | 561-494-1120 (O) | | | 561-351-0510 (M) | | | [email protected] | | | |
|
|
| Review Stop |
SURVEY |
SURVEYING |
| Rev No |
3 |
Status |
P |
Date |
08-12-2022 |
|
|
Cont ID |
|
| Sent By |
vnoel |
Date |
08-12-2022 |
Time |
10:10 |
Rev Time |
0.00 |
| Received By |
vnoel |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SURVEY |
SURVEYING |
| Rev No |
2 |
Status |
F |
Date |
10-26-2021 |
|
|
Cont ID |
|
| Sent By |
vnoel |
Date |
10-26-2021 |
Time |
11:19 |
Rev Time |
0.00 |
| Received By |
vnoel |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2021-10-26 11:23:44 | 1. AGREEMENTS ARE STILL BEING FINALIZED. | | | 2. PROPOSED PAVING STOPS AT EXISTING GATE WHICH IS 225' | | | +/- WEST OF EXISTING END OF PAVEMENT. EXTEND PAVING | | | EAST TO EXISTING PAVEMENT. | | | 3. PROPOSED FORCE MAIN IN 47TH PLACE N. WILL ALL BE | | | PRIVATE. LABEL AS SAME. |
|
|
| Review Stop |
SURVEY |
SURVEYING |
| Rev No |
1 |
Status |
F |
Date |
07-06-2021 |
|
|
Cont ID |
|
| Sent By |
vnoel |
Date |
07-06-2021 |
Time |
08:57 |
Rev Time |
|
| Received By |
vnoel |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2021-07-06 09:04:42 | 1. PLANS HAVE BEEN SENT TO WATER RESOURCES FOR THEIR | | | REVIEW. | | | 2. EAST END OF PROPOSED ROADWAY IS CALLED OUT AS 12' WD | | | INSTEAD OF 20'. | | | 3. EASEMENT AND MOU AGREEMENT WILL NEED TO BE FINALIZED | | | PRIOR TO SITE PLAN APPROVAL. |
|
|
| Review Stop |
TRAFFIC |
TRAFFIC ENGINEERING |
| Rev No |
3 |
Status |
P |
Date |
08-03-2022 |
|
|
Cont ID |
|
| Sent By |
|
Date |
08-03-2022 |
Time |
|
Rev Time |
0.00 |
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2022-08-03 09:36:41 | APPROVED WITH THE FOLLOWING CONDITION: PROVIDE COUNTY | | | TPS LETTER ONCE RECEIVED/AVAILABLE | | | | | | 1) SATISFIED. PROVIDE COUNTY TPS LETTER. THE TRAFFIC | | | STATEMENT NEEDS TO BE SIGNED AND SEALED BY A | | | PROFESSIONAL ENGINEER, EXACT NUMBER OF TRIPS GENERATED | | | NEEDS TO BE PROVIDED BASED ON EITHER COUNTY OR ITE TRIP | | | GENERATION MANUAL RATES. | | | 2) SATISFIED. PROVIDE AUTOTURN ANALYSIS FOR GARBAGE | | | TRUCK AND SERVICE VEHICLES DRIVING IN AND OUT OF THE | | | PROPOSED DEVELOPMENT WITH VEHICLE DYNAMIC ENVELOPES | | | CLEARLY DEFINED. ANALYSIS SHOULD BE PROVIDED IN A | | | SEPARATE FILE/DRAWING | | | | | | VALERIO ORICCHIO | | | CITY TRANSPORTATION ENGINEER | | | 561-494-1092 | | | [email protected] | | | |
|
|
| Review Stop |
TRAFFIC |
TRAFFIC ENGINEERING |
| Rev No |
2 |
Status |
F |
Date |
10-15-2021 |
|
|
Cont ID |
|
| Sent By |
|
Date |
10-15-2021 |
Time |
|
Rev Time |
0.00 |
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2021-10-15 15:34:31 | 1) NOT SATISFIED. PROVIDE COUNTY TPS LETTER. THE | | | TRAFFIC STATEMENT NEEDS TO BE SIGNED AND SEALED BY A | | | PROFESSIONAL ENGINEER, EXACT NUMBER OF TRIPS GENERATED | | | NEEDS TO BE PROVIDED BASED ON EITHER COUNTY OR ITE TRIP | | | GENERATION MANUAL RATES. | | | 2) SATISFIED. PROVIDE AUTOTURN ANALYSIS FOR GARBAGE | | | TRUCK AND SERVICE VEHICLES DRIVING IN AND OUT OF THE | | | PROPOSED DEVELOPMENT WITH VEHICLE DYNAMIC ENVELOPES | | | CLEARLY DEFINED. ANALYSIS SHOULD BE PROVIDED IN A | | | SEPARATE FILE/DRAWING | | | | | | VALERIO ORICCHIO | | | CITY TRANSPORTATION ENGINEER | | | 561-494-1092 | | | [email protected] | | | | | | |
|
|
| Review Stop |
TRAFFIC |
TRAFFIC ENGINEERING |
| Rev No |
1 |
Status |
F |
Date |
07-07-2021 |
|
|
Cont ID |
|
| Sent By |
|
Date |
07-07-2021 |
Time |
|
Rev Time |
|
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2021-07-07 17:07:11 | TRAFFIC COMMENTS | | | 1) PROVIDE COUNTY TPS LETTER. | | | | | | SITE COMMENTS | | | 1) PROVIDE AUTOTURN ANALYSIS FOR GARBAGE TRUCK AND | | | SERVICE VEHICLES DRIVING IN AND OUT OF THE PROPOSED | | | DEVELOPMENT WITH VEHICLE DYNAMIC ENVELOPES CLEARLY | | | DEFINED. ANALYSIS SHOULD BE PROVIDED IN A SEPARATE | | | FILE/DRAWING | | | | | | VALERIO ORICCHIO | | | CITY TRANSPORTATION ENGINEER | | | 561-494-1092 | | | [email protected] | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
08-12-2022 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
08-12-2022 |
Time |
10:00 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
08-12-2022 |
Time |
09:48 |
Sent To |
|
|
| Notes |
| 2022-08-12 10:00:51 | PLANS AND PLATS REVIEW COMMITTEE (PPRC) ZONING REVIEW | | | ________________________________________ | | | | | | DATE OF REVIEW: 08.12.2022 | | | PROJECT NO.: Z21050030 | | | CASE NO.: ISPR 21-08 | | | ________________________________________ | | | | | | PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING | | | REVIEW COMMENTS: | | | | | | 1. [ SATISFIED ] - AS REQUIRED BY THE DEVELOPMENT | | | APPLICATION: | | | | | | 1.1. [ SATISFIED ] - A JUSTIFICATION STATEMENT SHALL | | | BE PROVIDED. | | | | | | 1.2. [ SATISFIED ] - OWNER?S CONSENT FORM (SIGNED / | | | NOTARIZED) SHALL BE PROVIDED ? IT IS STAFF?S | | | UNDERSTANDING THAT THIS IS BEING COORDINATED WITH THE | | | LEASE, WHICH HAS NOT BEEN FINALIZED. | | | | | | 2. [ SATISFIED - STAFF WILL ADDRESS AS NEEDED ] - STAFF | | | IS LOOKING INTO SOME POSSIBLE INCONSISTENCIES BETWEEN | | | THE ZONING AND LAND DEVELOPMENT REGULATIONS AND THE | | | COMPREHENSIVE PLAN REGARDING THE ALLOWANCE OF UTILITY | | | FACILITIES IN THE CONSERVATION (CON) FUTURE LAND USE | | | DESIGNATION. ADDITIONAL INFORMATION WILL BE PROVIDED IN | | | THE NEAR FUTURE. | | | | | | 3. [ SATISFIED ] - INSTEAD OF USING THE TERM ?PROPERTY | | | LINE? IT SHOULD BE IDENTIFIED AS A ?LEASE LINE?. | | | | | | 4. [ SATISFIED - PROVISION BEING ADDED INTO THE LEASE | | | AGREEMENT ] - PURSUANT TO SEC. 94-273 OF THE CITY?S | | | ZLDRS, UTILITY FACILITIES ARE REQUIRED TO BE LANDSCAPED | | | TO MEET THE MINIMUM REQUIREMENTS. WHILE IT DOES NOT | | | MAKE SENSE TO INSTALL LANDSCAPING AT THIS TIME GIVEN | | | ITS LOCATION AND SURROUNDINGS, BUT IS THERE ANY WAY | | | THAT ENSURE THAT THE LANDSCAPING WOULD BE INSTALLED IF | | | THE SURROUNDING AREA IS EVER DEVELOPED? AS CURRENTLY | | | DESIGNATED ON THE CITY?S FUTURE LAND USE MAP, THE AREA | | | IMMEDIATELY EAST OF THE TRANSMISSION CORRIDOR IS | | | DESIGNATED AS SINGLE FAMILY. | | | ________________________________________ | | | | | | PLEASE NOTE THE FOLLOWING WHEN RESUBMITTING: | | | | | | A) WRITTEN RESPONSES TO COMMENTS MADE BY ALL | | | DEPARTMENTS SHALL BE PROVIDED UPON RESUBMISSION. | | | | | | B) ELECTRONIC COPIES OF ALL REVISED PLANS AND/OR | | | DOCUMENTS SHALL BE PROVIDED. | | | | | | C) PLEASE NOTE THAT RE-SUBMITTALS MAY BE SUBJECT TO | | | ADDITIONAL COMMENTS. | | | | | | D) IF NO RESPONSE IS RECEIVED WITHIN 60 DAYS OF THE | | | ISSUANCE OF THESE COMMENTS, THE APPLICATION WILL BE | | | CONSIDERED WITHDRAWN AND ANY FURTHER ACTION WILL | | | REQUIRE SUBMISSION OF A NEW DEVELOPMENT APPLICATION. | | | | | | E) PLEASE NOTE THAT YOU WILL BE PERMITTED ONE (1) | | | RESUBMITTAL AT NO ADDITIONAL COST. IF PREVIOUSLY-ISSUED | | | COMMENTS CONTINUE TO NOT BE SUFFICIENTLY ADDRESSED, THE | | | APPLICANT WILL BE ACCESSED A RESUBMITTAL FEE. SUCH FEE | | | WILL BE 20% OF THE ORIGINAL APPLICATION FEE. | | | ________________________________________ | | | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | | | JOHN P. ROACH, AICP, PRINCIPAL PLANNER | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION | | | 401 CLEMATIS STREET - P.O. BOX 3147 | | | WEST PALM BEACH, FLORIDA 33402 | | | | | | P: 561.822.1448 | | | TTY: 800.955.8771 | | | E: [email protected] | | | | | | W: WPB.ORG | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
12-03-2021 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
12-03-2021 |
Time |
11:21 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
12-03-2021 |
Time |
11:20 |
Sent To |
|
|
| Notes |
| 2021-12-03 11:22:49 | PLANS AND PLATS REVIEW COMMITTEE (PPRC) ZONING REVIEW | | | ________________________________________ | | | | | | DATE OF REVIEW: 12.03.2021 | | | PROJECT NO.: Z21050030 | | | CASE NO.: ISPR 21-08 | | | ________________________________________ | | | | | | PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING | | | REVIEW COMMENTS: | | | | | | 1. [ PARTIALLY SATISFIED ] - AS REQUIRED BY THE | | | DEVELOPMENT APPLICATION: | | | | | | 1.1. [ SATISFIED ] - A JUSTIFICATION STATEMENT SHALL | | | BE PROVIDED. | | | | | | 1.2. [ NOT SATISFIED ] - OWNER?S CONSENT FORM (SIGNED | | | / NOTARIZED) SHALL BE PROVIDED ? IT IS STAFF?S | | | UNDERSTANDING THAT THIS IS BEING COORDINATED WITH THE | | | LEASE, WHICH HAS NOT BEEN FINALIZED. | | | | | | 2. [ SATISFIED - STAFF WILL ADDRESS AS NEEDED ] - STAFF | | | IS LOOKING INTO SOME POSSIBLE INCONSISTENCIES BETWEEN | | | THE ZONING AND LAND DEVELOPMENT REGULATIONS AND THE | | | COMPREHENSIVE PLAN REGARDING THE ALLOWANCE OF UTILITY | | | FACILITIES IN THE CONSERVATION (CON) FUTURE LAND USE | | | DESIGNATION. ADDITIONAL INFORMATION WILL BE PROVIDED IN | | | THE NEAR FUTURE. | | | | | | 3. [ SATISFIED ] - INSTEAD OF USING THE TERM ?PROPERTY | | | LINE? IT SHOULD BE IDENTIFIED AS A ?LEASE LINE?. | | | | | | 4. [ SATISFIED - PROVISION BEING ADDED INTO THE LEASE | | | AGREEMENT ] - PURSUANT TO SEC. 94-273 OF THE CITY?S | | | ZLDRS, UTILITY FACILITIES ARE REQUIRED TO BE LANDSCAPED | | | TO MEET THE MINIMUM REQUIREMENTS. WHILE IT DOES NOT | | | MAKE SENSE TO INSTALL LANDSCAPING AT THIS TIME GIVEN | | | ITS LOCATION AND SURROUNDINGS, BUT IS THERE ANY WAY | | | THAT ENSURE THAT THE LANDSCAPING WOULD BE INSTALLED IF | | | THE SURROUNDING AREA IS EVER DEVELOPED? AS CURRENTLY | | | DESIGNATED ON THE CITY?S FUTURE LAND USE MAP, THE AREA | | | IMMEDIATELY EAST OF THE TRANSMISSION CORRIDOR IS | | | DESIGNATED AS SINGLE FAMILY. | | | ________________________________________ | | | | | | PLEASE NOTE THE FOLLOWING WHEN RESUBMITTING: | | | | | | A) WRITTEN RESPONSES TO COMMENTS MADE BY ALL | | | DEPARTMENTS SHALL BE PROVIDED UPON RESUBMISSION. | | | | | | B) ELECTRONIC COPIES OF ALL REVISED PLANS AND/OR | | | DOCUMENTS SHALL BE PROVIDED. | | | | | | C) PLEASE NOTE THAT RE-SUBMITTALS MAY BE SUBJECT TO | | | ADDITIONAL COMMENTS. | | | | | | D) IF NO RESPONSE IS RECEIVED WITHIN 60 DAYS OF THE | | | ISSUANCE OF THESE COMMENTS, THE APPLICATION WILL BE | | | CONSIDERED WITHDRAWN AND ANY FURTHER ACTION WILL | | | REQUIRE SUBMISSION OF A NEW DEVELOPMENT APPLICATION. | | | | | | E) PLEASE NOTE THAT YOU WILL BE PERMITTED ONE (1) | | | RESUBMITTAL AT NO ADDITIONAL COST. IF PREVIOUSLY-ISSUED | | | COMMENTS CONTINUE TO NOT BE SUFFICIENTLY ADDRESSED, THE | | | APPLICANT WILL BE ACCESSED A RESUBMITTAL FEE. SUCH FEE | | | WILL BE 20% OF THE ORIGINAL APPLICATION FEE. | | | ________________________________________ | | | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | | | JOHN P. ROACH, AICP, PRINCIPAL PLANNER | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION | | | 401 CLEMATIS STREET - P.O. BOX 3147 | | | WEST PALM BEACH, FLORIDA 33402 | | | | | | P: 561.822.1448 | | | TTY: 800.955.8771 | | | E: [email protected] | | | | | | W: WPB.ORG | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
07-08-2021 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
07-08-2021 |
Time |
12:32 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
07-08-2021 |
Time |
12:32 |
Sent To |
|
|
| Notes |
| 2021-07-08 12:32:41 | PLANS AND PLATS REVIEW COMMITTEE (PPRC) ZONING REVIEW | | | ________________________________________ | | | | | | DATE OF REVIEW: 07.08.2021 | | | PROJECT NO.: | | | CASE NO.: ISPR 21-08 | | | ________________________________________ | | | | | | PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING | | | REVIEW COMMENTS: | | | | | | 1. AS REQUIRED BY THE DEVELOPMENT APPLICATION: | | | | | | 1.1. A JUSTIFICATION STATEMENT SHALL BE PROVIDED. | | | | | | 1.2. OWNER?S CONSENT FORM (SIGNED / NOTARIZED) SHALL BE | | | PROVIDED ? IT IS STAFF?S UNDERSTANDING THAT THIS IS | | | BEING COORDINATED WITH THE LEASE, WHICH HAS NOT BEEN | | | FINALIZED. | | | | | | 2. STAFF IS LOOKING INTO SOME POSSIBLE INCONSISTENCIES | | | BETWEEN THE ZONING AND LAND DEVELOPMENT REGULATIONS AND | | | THE COMPREHENSIVE PLAN REGARDING THE ALLOWANCE OF | | | UTILITY FACILITIES IN THE CONSERVATION (CON) FUTURE | | | LAND USE DESIGNATION. ADDITIONAL INFORMATION WILL BE | | | PROVIDED IN THE NEAR FUTURE. | | | | | | 3. INSTEAD OF USING THE TERM ?PROPERTY LINE? IT SHOULD | | | BE IDENTIFIED AS A ?LEASE LINE?. | | | | | | 4. PURSUANT TO SEC. 94-273 OF THE CITY?S ZLDRS, UTILITY | | | FACILITIES ARE REQUIRED TO BE LANDSCAPED TO MEET THE | | | MINIMUM REQUIREMENTS. WHILE IT DOES NOT MAKE SENSE TO | | | INSTALL LANDSCAPING AT THIS TIME GIVEN ITS LOCATION AND | | | SURROUNDINGS, BUT IS THERE ANY WAY THAT ENSURE THAT THE | | | LANDSCAPING WOULD BE INSTALLED IF THE SURROUNDING AREA | | | IS EVER DEVELOPED? AS CURRENTLY DESIGNATED ON THE | | | CITY?S FUTURE LAND USE MAP, THE AREA IMMEDIATELY EAST | | | OF THE TRANSMISSION CORRIDOR IS DESIGNATED AS SINGLE | | | FAMILY. | | | ________________________________________ | | | | | | PLEASE NOTE THE FOLLOWING WHEN RESUBMITTING: | | | | | | A) WRITTEN RESPONSES TO COMMENTS MADE BY ALL | | | DEPARTMENTS SHALL BE PROVIDED UPON RESUBMISSION. | | | | | | B) ELECTRONIC COPIES OF ALL REVISED PLANS AND/OR | | | DOCUMENTS SHALL BE PROVIDED. | | | | | | C) PLEASE NOTE THAT RE-SUBMITTALS MAY BE SUBJECT TO | | | ADDITIONAL COMMENTS. | | | | | | D) IF NO RESPONSE IS RECEIVED WITHIN 60 DAYS OF THE | | | ISSUANCE OF THESE COMMENTS, THE APPLICATION WILL BE | | | CONSIDERED WITHDRAWN AND ANY FURTHER ACTION WILL | | | REQUIRE SUBMISSION OF A NEW DEVELOPMENT APPLICATION. | | | | | | E) PLEASE NOTE THAT YOU WILL BE PERMITTED ONE (1) | | | RESUBMITTAL AT NO ADDITIONAL COST. IF PREVIOUSLY-ISSUED | | | COMMENTS CONTINUE TO NOT BE SUFFICIENTLY ADDRESSED, THE | | | APPLICANT WILL BE ACCESSED A RESUBMITTAL FEE. SUCH FEE | | | WILL BE 20% OF THE ORIGINAL APPLICATION FEE. | | | ________________________________________ | | | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | | | JOHN P. ROACH, AICP, PRINCIPAL PLANNER | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION | | | 401 CLEMATIS STREET - P.O. BOX 3147 | | | WEST PALM BEACH, FLORIDA 33402 | | | | | | P: 561.822.1448 | | | TTY: 800.955.8771 | | | E: [email protected] | | | | | | W: WPB.ORG | | | |
|
|
| |