 |
Plan Review Details - Project Z21050010
| Plan Review Stops For Project Z21050010 |
| Review Stop |
AIPP |
ART IN PUBLIC PLACES |
| Rev No |
2 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
AIPP |
ART IN PUBLIC PLACES |
| Rev No |
1 |
Status |
F |
Date |
06-09-2021 |
|
|
Cont ID |
|
| Sent By |
scwelter |
Date |
06-09-2021 |
Time |
14:31 |
Rev Time |
0.00 |
| Received By |
scwelter |
Date |
06-09-2021 |
Time |
14:33 |
Sent To |
|
|
| Notes |
| 2021-06-09 14:32:59 | PUBLIC ART REQUIREMENT: | | | IF TOTAL CONSTRUCTION COSTS OF THIS DEVELOPMENT ARE | | | OVER $500,000 IT WILL BE SUBJECT TO THE PUBLIC ART | | | REQUIREMENT AS PER CITY ORDINANCE. | | | SECTION 78-129: ALL PRIVATE DEVELOPMENT PROJECTS, | | | INCLUDING NEW CONSTRUCTION, OR THE RENOVATION OR | | | IMPROVEMENT OF AN EXISTING BUILDING, WHERE TOTAL | | | CONSTRUCTION COSTS ARE EQUAL TO OR GREATER THAN | | | $500,000 ARE SUBJECT TO THE PUBLIC ART REQUIREMENT. | | | OPTION 1: INSTALL ARTWORK ON THE DEVELOPMENT SITE | | | VALUED IN AN AMOUNT NOT LESS THAN ONE PERCENT OF THE | | | TOTAL CONSTRUCTION COSTS; OR | | | OPTION 2: CONTRIBUTE AN AMOUNT EQUAL TO 75 PERCENT OF | | | ONE PERCENT OF THE TOTAL CONSTRUCTION COSTS FOR DEPOSIT | | | TO THE PUBLIC ART ACCOUNT. | | | A COMPLETED PUBLIC ART ASSESSMENT APPLICATION IS | | | REQUIRED AT TIME OF BUILDING PERMIT SUBMITTAL. | | | | | | PLEASE CONTACT SYBILLE WELTER AT [email protected] OR | | | 561.822.1521 TO OBTAIN AN APPLICATION AND REVIEW THE | | | REQUIREMENTS. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
06-09-2021 |
|
|
Cont ID |
|
| Sent By |
rbrown |
Date |
06-09-2021 |
Time |
20:23 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
06-09-2021 |
Time |
20:23 |
Sent To |
|
|
| Notes |
| 2021-06-09 20:34:14 | DEVELOPMENT SERVICES DEPARTMENT, BUILDING DIVISION, | | | COMMENTS: | | | | | | 1. THIS REVIEW IS A CURSORY REVIEW AS IT RELATES TO THE | | | SITE. IT IS NOT A REVIEW FOR FULL COMPLIANCE WITH | | | FLORIDA BUILDING CODE. THE FOLLOWING COMMENTS ARE TO BE | | | ADDRESSED FOR THE BUILDING PERMIT APPLICATION. | | | | | | 2. FLOOD ZONE. ACCORDING TO THE ADOPTED FLOOD INSURANCE | | | RATE MAPS (FIRMS), THE PROPOSED BUILDING IS IN FLOOD | | | ZONE AE, WITH A BASE FLOOD ELEVATION OF 7 FT NAVD. THE | | | FIRST FLOOR OF THE BUILDING AND ALL ASSOCIATED | | | MECHANICAL EQUIPMENT (CHILLERS, GENERATORS ETC.) SHALL | | | BE 24 INCHES (FREEBOARD) ABOVE THE BASE FLOOD | | | ELEVATION. | | | | | | 3. VAN ACCESSIBLE PARKING SPACES. THE PLANS SHOW | | | ACCESSIBLE PARKING SPACES BUT NONE OF THEM ARE MARKED | | | AS VAN ACCESSIBLE. PER SECTION 208.2.4 OF FLORIDA | | | ACCESSIBILITY CODE, ONE IN EVERY SIX REQUIRED | | | ACCESSIBLE SPACES (AT LEAST ONE) IN A PARKING | | | STRUCTURE, SHALL BE ?VAN ACCESSIBLE? AND DESIGNED IN | | | ACCORDANCE WITH SECTION OF 502 OF FLORIDA ACCESSIBILITY | | | CODE (VERTICAL CLEARANCE NOT LESS THAN 98 INCHES AT | | | SPACE AND VEHICULAR ACCESS ROUTE) | | | | | | 4. UNITY OF TITLE. FOR ANY BUILDING CROSSING A PROPERTY | | | LINE, EITHER A RECORDED UNITY OF TITLE, OR SOME OTHER | | | APPROVED LEGAL INSTRUMENT, SHALL BE INCLUDED WITH THE | | | PERMIT APPLICATION, OR THE BUILDING MUST HAVE A FIRE | | | WALL ALONG THE PROPERTY LINE, PER SECTION 202 OF | | | FLORIDA BUILDING CODE, BUILDING, FIRE SEPARATION | | | DISTANCE. | | | | | | 5. BUILDING SIZE. WHEN SUBMITTED FOR BUILDING PERMIT, | | | THE PLANS SHALL SHOW THAT THE TYPE OF CONSTRUCTION FOR | | | THE BUILDINGS WILL BE IN ACCORDANCE WITH THE HEIGHT, | | | AREA AND OCCUPANCY LIMITATIONS IN CHAPTER 5 OF THE | | | FLORIDA BUILDING CODE. | | | | | | 6. ENCLOSED PARKING GARAGES. IF THE PARKING GARAGE DOES | | | NOT HAVE WALL OPENINGS, OR SUFFICIENT WALL OPENINGS TO | | | MEET THE DEFINITION OF AN OPEN PARKING GARAGE, IT WILL | | | BE CONSIDERED AN ENCLOSED PARKING GARAGE AND MUST HAVE | | | EXHAUST SYSTEMS. THE EXHAUST SYSTEMS SHALL BE DESIGNED | | | TO MINIMIZE NOISE LEVELS USING INLINE FAN SILENCERS OR | | | OTHER APPROVED METHODS. | | | | | | 7. EAST EXIT STAIRS. OCCUPANTS LEAVING THE BUILING VIA | | | TTHE EAST EXIT STAIRS IN AN EMERGENCY HAVE ONLY ONE WAY | | | TO GET TO THE STREET AND ARE COMPELLED TO PASS ALONG | | | THE SIDE OF THE BUILDING WITHIN 10 FEET OF FROM THE | | | WALLS OF THE BUILDING. PER SECTION 1028.4.2 EITHER THE | | | ADJACENT WALLS MUST BE 1 HOUR FIRE-RATED OR THE EGRESS | | | PATH MUST BE NOT LESS THAN 10 FEET AWAY FROM THE | | | BUILDING. | | | | | | 8. SEPARATE PERMITS REQUIRED. ALL APPLICABLE PERMITS | | | AND SUB-PERMITS MUST BE OBTAINED BEFORE COMMENCING THE | | | WORK. SEPARATE PERMITS, PLANS AND FEES, ARE REQUIRED | | | FOR SIGNS, SWIMMING POOLS AND SPAS, GAS SYSTEMS, | | | GENERATORS, FIRE ALARM SYSTEMS, FIRE SPRINKLER AND | | | OTHER FIRE SUPPRESSION SYSTEMS, GREASE INTERCEPTORS, | | | SITE LIGHTING, SITE LANDSCAPE, SITE IRRIGATION, ETC. | | | | | | 9. CONTRACTOR VEHICLE PARKING. PROPERTY OWNER AND | | | CONTRACTOR SHALL MAKE ARRANGEMENTS FOR PARKING OF | | | CONTRACTOR VEHICLES TO MINIMIZE THE IMPACT ON ALL | | | NEIGHBORING PROPERTIES. | | | | | | 10. PROTECTION OF NEIGHBORING PROPERTY. PROPERTY OWNER | | | AND CONTRACTOR SHALL PROTECT ALL NEIGHBORING PROPERTY, | | | INCLUDING VEHICLES, FROM DAMAGE OR DIRT CAUSED BY THE | | | CONSTRUCTION, AND SHALL NOTIFY THE OCCUPANTS OF | | | NEIGHBORING PROPERTIES ABOUT ALL STAGES OF CONSTRUCTION | | | THAT MAY AFFECT THE USE OF THEIR PROPERTY. | | | | | | 11. BUILDING ADDRESS. EACH SEPARATE BUILDING, AND UNIT | | | WITH AN INDEPENDENT ENTRANCE FROM THE STREET, SHALL | | | HAVE A SEPARATE ADDRESS ASSIGNED BASED ON THE LOCATION | | | OF THE BUILDING ENTRANCE. FOR STREET ADDRESSING, | | | CONTACT CAROLINE PUELL, ADDRESSING COORDINATOR, AT | | | (561) 805 6659, OR BY EMAIL: [email protected] | | | | | | 12. ART IN PUBLIC PLACES. THIS PROJECT WILL BE SUBJECT | | | TO ART IN PUBLIC PLACES (AIPP) ASSESSMENT. FOR ADVICE | | | ON THE PROVISION OF PUBLIC ARTWORK IN LIEU OF THE AIPP | | | ASSESSMENT, CONTACT SYBILLE WELTER, ART IN PUBLIC | | | PLACES COORDINATOR, AT (561) 822-1521, OR BY EMAIL: | | | [email protected] | | | | | | ROBERT BROWN | | | BUILDING OFFICIAL | | | TEL: 561 805 6652 | | | EMAIL: [email protected] | | | |
|
|
| Review Stop |
ENG - PPRC |
ENGINEERING - PPRC |
| Rev No |
2 |
Status |
F |
Date |
10-12-2021 |
|
|
Cont ID |
|
| Sent By |
rrossano |
Date |
10-12-2021 |
Time |
|
Rev Time |
0.00 |
| Received By |
rrossano |
Date |
10-12-2021 |
Time |
|
Sent To |
|
|
| Notes |
| 2021-10-12 10:49:53 | COMMENTS FROM RICK ROSSANO, PROJECT COORDINATOR, ENG. | | | SERVICES DEPT., 561-494-1098 [email protected] : | | | | | | 1. CONFIRM THAT A COMPLETED LOS ANALYSIS SUMMARY TABLE | | | HAS BEEN SUBMITTED DIRECTLY TO ENGINEERING (SHEET 33 OF | | | CITY OF WPB DEVELOPMENT APPLICATION). | | | 2. CHECK TO SEE IF FDEP FORMS FOR PROPOSED SANITARY | | | SEWER ARE REQUIRED. | | | 3. FOR FORMAL ENGINEERING SUBMITTAL, PROVIDE | | | CALCULATIONS ON PLANS OF EXISTING AND PROPOSED DEMANDS | | | FOR WATER & SEWER (AVERAGE, MAXIMUM AND PEAK) AND FIRE | | | FLOW DEMANDS. CALCULATIONS SHALL BE PER FAC 64E-8 FOR | | | WATER AND PER FAC 64-E.008 FOR SEWER. | | | 4. PROVIDE CCTV VIDEO OF EXISTING SANITARY SEWER AND | | | STORMWATER PIPES ALONG ENTIRE PROJECT FRONTAGE. | | | (RESPONSE LETTER INDICATES IT HAS BEEN PROVIDED, UNABLE | | | TO LOCATE.) | | | 5. PLEASE PROVIDE CALCULATIONS OF REVISED PERVIOUS AND | | | IMPERVIOUS CALCULATIONS FOR THE PROPOSED IMPACTED | | | AREAS. | | | 6. COORDINATE WITH MARK HURLEY, FIELD CUSTOMER SERVICE | | | SUPERVISOR WITH CITY OF WPB PUBLIC UTILITIES, REGARDING | | | PLACEMENT OF BACKFLOW DEVICES AND WATER METERS. CONTACT | | | HIM AT 561-494-2262 OR [email protected] | | | 7. FOR FORMAL ENGINEERING SUBMITTAL , PLANS SHALL SHOW | | | PROPOSED LOCATIONS AND DIMENSIONS OF ALL WATER, | | | STORMWATER, AND SANITARY AND SEWER LINES, INCLUDING | | | STUBS TO EACH PROPERTY LINE FOR WATER AND SANITARY | | | SEWERS, THE MAKE AND MODEL OF ALL VALVES, METERS, AND | | | OTHERS DEVICES TO BE INSTALLED ON THE SYSTEM, CATCH | | | BASINS, CULVERTS, DITCHES INCLUDING GRADES, PIPES | | | SIZES, MATERIALS, ELEVATIONS, ASSUMPTIONS, | | | CALCULATIONS, INVERT ELEVATIONS FOR ALL INLETS AND | | | MANHOLES AND PROFILES OF SANITARY SEWER LINES. ALL | | | AVAILABLE ELEVATION SHALL BE SHOWN ON THE PROFILE VIEW. | | | DIRECTION OF FLOW SHALL BE SHOWN ON PLAN VIEW ON PLAN | | | VIEW FOR ALL SANITARY AND STORM SEWERS. ADDITIONALLY, | | | PLAN VIEW SHALL SHOW ALL EXISTING AND PROPOSED | | | UNDERGROUND UTILITY LAYOUT, INCLUDING FIBER OPTIC, | | | ELECTRIC, GAS, AND CABLEVISION & TELECOMMUNICATION | | | FACILITIES LOCATED ON THE RIGHT-OF-WAY. | | | 8. FOR FORMAL ENGINEERING SUBMITTAL, CUT AND CAP | | | UTILITIES NOT IN USE, AND REMOVE ANY ABANDONED UTILITY | | | LINES LARGER THAN 2 INCHES FROM CITY RIGHT OF WAY. | | | 9. FOR FORMAL ENGINEERING SUBMITTAL, PROVIDE DEDICATED | | | UTILITY EASEMENTS TO ALLOW ACCESS FOR CITY PERSONNEL TO | | | PROPOSED UTILITY WATER METERS. ADJUST PROPOSED EASEMENT | | | TO EXCLUDE BACKFLOW (BF MUST BE ON PRIVATE PROPERTY | | | OUTSIDE OF EASEMENT). | | | 10. FOR FORMAL ENGINEERING SUBMITTAL, PLEASE PROVIDE | | | ENLARGED VIEW ON PLANS OF PROPOSED LOCATION OF WATER | | | METER AND BACKFLOW PREVENTION. | | | 11. FOR FORMAL ENGINEERING SUBMITTAL, PLEASE CALLOUT | | | DOMESTIC BACKFLOW PREVENTER AS RPPA AND FIRE BACKFLOW | | | PREVENTER AS DCDA. SPECIFY LEAD FREE DESIGN ON ALL | | | BACKFLOWS. | | | 12. FOR FORMAL ENGINEERING SUBMITTAL, SFWMD ERP AND | | | NPDES NOI REQUIREMENTS WILL BE ENFORCED. | | | - AN NOI IS REQUIRED FOR PROJECTS THAT: | | | - 1) DISTURB ONE OF MORE ACRES OF LAND OR DISTURB LESS | | | THAN ON ACRE OF LAND BUT ARE PART OF A COMMON PLAN OF | | | DEVELOPMENT OR SALE; AND | | | - 2) DISCHARGE STORMWATER TO SURFACE WATERS OF THE | | | STATE OR TO SURFACE WATERS OF THE STATE THROUGH A | | | MUNICIPAL SEPARATE STORM SEWER SYSTEM (MS4). | | | - THE SFWMD ERP CAN BE OBTAINED THROUGH A 10-2 SELF | | | CERTIFICATION THROUGH FDEP OR AN ERP APPLICATION | | | THROUGH SFWMD. EITHER WAY, THE DEVELOPER/ENGINEER SHALL | | | SUBMIT A COPY OF THE ERP PERMIT OR FDEP ACKNOWLEDGEMENT | | | OF THE 10-2 CERTIFICATION. IF THE ENGINEERING PLANS DO | | | NOT INCLUDE AN EROSION CONTROL PLAN, THEN THE | | | CONTRACTOR SHOULD SUBMIT ONE PRIOR TO RECEIVING THE | | | ENGINEERING PERMIT. | | | 13. FOR FORMAL ENGINEERING SUBMITTAL, PROVIDE PROFILES | | | OF PROPOSED AND EXISTING WATER AND SEWER WITHIN RIGHT | | | OF WAY AND SHOW ANY CROSSINGS/CONFLICTS. | | | 14. FOR FORMAL ENGINEERING SUBMITTAL, WHEN SUBMITTING | | | APPROVED MATERIALS LIST, PLEASE PROVIDE MATERIAL/CUT | | | SHEETS FOR ALL PROPOSED BACKFLOW DEVICES SHOWING | | | SPECIFIC MODEL NUMBER AND SPECIFYING USC APPROVED | | | LEAD-FREE DESIGN. | | | 15. FOR FORMAL ENGINEERING SUBMITTAL CLEARLY SHOW ROAD | | | RIGHT OF WAY. | | | 16. FOR FORMAL ENGINEERING SUBMITTAL PROVIDE SANITARY | | | ELEVATIONS AT MANHOLE TIE-IN. | | | 17. FOR FORMAL ENGINEERING SUBMITTAL, IF SANITARY LINES | | | ARE PROPOSED IN ROW PLEASE SHOW ADJACENT SANITARY | | | LATERAL LOCATIONS AND SHOW ADDRESSES OF ADJACENT | | | PARCELS. | | | 18. FOR FORMAL ENGINEERING SUBMITTAL, IF WATER LINES | | | ARE BEING REPLACED IN ROW, SHOW ADJACENT PARCEL | | | ADDRESSES. | | | 19. FOR FORMAL ENGINEERING SUBMITTAL, WHEN TRENCHING IN | | | IN CITY MAINTAINED ROADWAY AREAS ADD NOTE TO PROVIDE 50 | | | FT. PAVEMENT RESTORATION TRANSITION ON EACH SIDE OF | | | PROPOSED TRENCH PER CURRENT CITY OF WPB STANDARD DETAIL | | | GC-8. | | | 20. PLEASE RESPOND TO ALL COMMENTS IN WRITING AND | | | INCLUDE PROJECT NAME, ADDRESS AND PERMIT NUMBER | | | (Z-XXXXXXXX). | | | | | | COMMENTS FROM MARK HURLEY, FIELD CUSTOMER SERVICE | | | SUPER., WPB PUBLIC UTILITIES, 561-494-2262 OR | | | [email protected]: | | | | | | PLEASE SHOW ALL EXISTING WATER SERVICES, METERS, AND | | | BACKFLOW ASSEMBLIES ON THE WATER PLAN AND LABEL WHAT IS | | | HAPPENING TO THEM. | | | RESPONSE: EXISTING SERVICES ARE SHOWN ON SHEET C4. NOTE | | | ON PLANS REQUIRES ANY UNUSED SERVICES TO BE ABANDONED | | | AND CAPPED AT THE MAIN. | | | FOLLOWUP: FOR FORMAL ENGINEERING SUBMITTAL, | | | SPECIFICALLY CALLOUT AND LABEL EXISTING WATER SERVICE | | | THAT WILL BE ABANONDED AND CAPPED ON WATER PLAN. ALSO | | | SHOW AND LABEL EXISTING WATER SERVICES AND SEWER | | | LATERALS FOR THE PROPERTIES ON WEST SIDE OF FLAGLER | | | DRIVE. | | | | | | THERE APPEARS TO BE A TREE CONFLICT WITH UTILITY POLE | | | NEAR SOUTHWEST CORNER OF PROPERTY. | | | RESPONSE: THE OVERHEAD LINES ARE PROPOSED TO BE PLACED | | | UNDERGROUND ON THE SUBJECT SITE. | | | FOLLOWUP: SHOW AND LABEL ANY PROPOSED PAD TRANSFORMERS | | | ON PLANS. | | | | | | | | | NEW COMMENTS: | | | | | | -IS A DO NOT ENTER SIGN NEEDED FOR THE NORTH DRIVEWAY? | | | | | | -SOME TREES ARE IN SIGHT TRIANGLES. IS THAT ALRIGHT? | | | | | | -THERE IS RECTANGULAR OBJECT ABOUT 18 FEET SOUTH OF | | | CLEANOUTS ON CIVIL PLANS, BUT NOT ON OTHER PLANS. | | | PLEASE LABEL WHAT IT IS AND UPDATE OTHER PLANS IF | | | NEEDED. | | | | | | -WILL DOCK NEED FIRE PROTECTION? | | | | | | -DOES WATER DEMAND CALCULATION INCLUDE IRRIGATION AND | | | DOCK USE? DOES SEWER DEMAND INCLUDE THE DOCK USE? | | | | | | -WATER PIPE TO DOCK NEEDS TO COMPLY WITH ANY PLUMBING | | | BACKFLOW PROTECTION REQUIREMENTS. | | | | | | -FOR FORMAL ENGINEERING SUBMITTAL: ADD INVERT ELEVATION | | | INFO FOR NORTH SEWER MANHOLE IN FLAGLER DR., ADD FIRE | | | FLOW CALCULATIONS TO WATER PLAN, CALLOUT CROSSING | | | ELEVATION INFO FOR ANY UTILITIES IN CLOSE PROXIMITY TO | | | PROPOSED SEWER LATERAL. | | | | | | -WILL THERE BE ANY EXFILTRATION TRENCHES ON SITE? IF | | | SO, LABEL ON CIVIL PLAN OR SHOW ON LEGEND. | | | | | | -WILL FDC HEIGHT BLOCK VISIBILITY OF STOP SIGN? | | | | | | -ON WATER PLAN, SHOW EXISTING GATE VALVE IN SIDEWALK | | | FOR EXISTING 4 INCH DIP WM. | | | | | | -LABEL DCDA ON WATER PLAN. | | | | | | -IN CASE ROOM WITH DCDA FLOODS, WILL THERE BE A DRAIN | | | PIPE? | | | | | | -ADD ABOVE GROUND TO LABEL OF 6 INCH METER. | | | | | | -SHOW AND LABEL GATE VALVE FOR FIRELINE NEAR WATER | | | MAIN. ADD POINT OF SERVICE WORDING TO LABEL. | | | | | | -FOR FORMAL ENGINEERING SUBMITTAL: CALLOUT CONNECTIONS | | | TO WATER MAINS AS TAPS OR CUT-IN TEES, LABEL ANY SAMPLE | | | POINTS ON WATER PLAN. | | | | | | | | | | | | NOTE THAT THERE MAY BE PENDING COMMENTS FROM MICHAEL | | | TECHNOW, PROJECT ENGINEER, WPB PUBLIC UTILITIES, | | | 561-494-1047, [email protected] | | | | | | FEEL FREE TO CONTACT US IF YOU HAVE ANY QUESTIONS OR | | | CONCERNS, THANKS. | | | |
|
|
| Review Stop |
ENG - PPRC |
ENGINEERING - PPRC |
| Rev No |
1 |
Status |
F |
Date |
06-07-2021 |
|
|
Cont ID |
|
| Sent By |
vnoel |
Date |
06-07-2021 |
Time |
08:18 |
Rev Time |
|
| Received By |
vnoel |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2021-06-07 08:20:34 | Z21050010 ? SCUBA CLUB 4708 N FLAGLER ? INITIAL REVIEW | | | 1. THE CITY OF WEST PALM BEACH HAS A NUMBER OF | | | REGULATIONS AND PERMIT REQUIREMENTS WHICH DIRECTLY | | | AFFECT THE DEVELOPMENT AND INSTALLATION OF WATER AND | | | WASTEWATER UTILITIES WITHIN THE CITY. TO VIEW | | | DEVELOPMENT PERMIT SUBMITTAL REQUIREMENTS AND OTHER | | | ENGINEERING RELATED DOCUMENTS, GO HERE: | | | HTTPS://WWW.WPB.ORG/GOVERNMENT/ENGINEERING | | | 2. CODE OF ORDINANCES, CITY OF WEST PALM BEACH, | | | FLORIDA, CODIFIED THROUGH ORD. NO. 4183-08, ADOPTED | | | SEPT. 22, 2008. (SUPPLEMENT NO. 18) CHAPTER 90 | | | UTILITIES, ARTICLE I. SEC. 90-7. | | | POLICY REGARDING EXTENSION OF WATER OR SEWER SERVICE | | | FACILITIES OF THE CITY: | | | THE WATER AND WASTEWATER SERVICE AGREEMENTS AND THE | | | CONSTRUCTION PERMITS ADDRESS RESERVATION OF CAPACITY | | | BASED ON USAGE, METER SIZE AND FEES, DESIGN STANDARDS, | | | BACKFLOW PREVENTION, FIRE SERVICE AND IRRIGATION. | | | 3. AS OF DECEMBER 20, 2015, THE CITY OF WEST PALM BEACH | | | CROSS-CONNECTION CONTROL MANUAL HAS BEEN REVISED, | | | STATING "ALL BACKFLOW DEVICES MUST BE LEAD-FREE". FOR | | | MORE INFORMATION, GO TO: | | | HTTPS://WWW.WPB.ORG/GOVERNMENT/ENGINEERING | | | 4. PLEASE SUBMIT A FORMAL AS-BUILT REQUEST FOR ALL CITY | | | OF WEST PALM BEACH-OWNED UTILITIES WITHIN THE PUBLIC | | | RIGHT OF WAY FOR THE ENTIRE EXTENT OF THE LIMITS OF | | | YOUR PROJECT. IDENTIFY TYPE OF UTILITY, LOCATION, PIPE | | | MATERIAL, AGE AND SIZE. PLEASE CONTACT JANICE TARBILL | | | IN THE WPB ENGINEERING SERVICES DEPARTMENT AT | | | [email protected] OR 561-494-1040 FOR FURTHER | | | ASSISTANCE. | | | 5. PLANS SHALL SHOW PROPOSED LOCATIONS AND DIMENSIONS | | | OF ALL WATER, STORMWATER, AND SANITARY AND SEWER LINES, | | | INCLUDING STUBS TO EACH PROPERTY LINE FOR WATER AND | | | SANITARY SEWERS, THE MAKE AND MODEL OF ALL VALVES, | | | METERS, AND OTHERS DEVICES TO BE INSTALLED ON THE | | | SYSTEM, CATCH BASINS, CULVERTS, DITCHES INCLUDING | | | GRADES, PIPES SIZES, MATERIALS, ELEVATIONS, | | | ASSUMPTIONS, CALCULATIONS, INVERT ELEVATIONS FOR ALL | | | INLETS AND MANHOLES AND PROFILES OF SANITARY SEWER | | | LINES. ALL AVAILABLE ELEVATION SHALL BE SHOWN ON THE | | | PROFILE VIEW. DIRECTION OF FLOW SHALL BE SHOWN ON PLAN | | | VIEW ON PLAN VIEW FOR ALL SANITARY AND STORM SEWERS. | | | PLEASE SHOW SLOPE % ON ALL SANITARY LINES AND CALL OUT | | | MATERIAL. ADDITIONALLY, PLAN VIEW SHALL SHOW ALL | | | EXISTING AND PROPOSED UNDERGROUND UTILITY LAYOUT, | | | INCLUDING FIBER OPTIC, ELECTRIC, GAS, AND CABLEVISION & | | | TELECOMMUNICATION FACILITIES LOCATED ON THE | | | RIGHT-OF-WAY. PROVIDE PROFILE AND CLEARANCES AT ALL | | | UTILITY CROSSINGS. | | | 6. CUT AND CAP UTILITIES NOT IN USE, AND REMOVE ANY | | | ABANDONED UTILITY LINES LARGER THAN 2 INCHES FROM CITY | | | ROW. | | | 7. PLEASE SUBMIT COMPLETED LOS ANALYSIS SUMMARY TABLE | | | DIRECTLY TO ENGINEERING (SHEET 33 OF CITY OF WPB | | | DEVELOPMENT APPLICATION). | | | 8. PROVIDE CALCULATIONS ON PLANS OF EXISTING AND | | | PROPOSED DEMANDS FOR WATER & SEWER (AVERAGE, MAXIMUM | | | AND PEAK) AND FIRE FLOW DEMANDS. CALCULATIONS SHALL BE | | | PER FAC 64E-6 FOR SEWER AND PER FAC 64-E.008 FOR WATER. | | | 9. SHOW VERTICAL DATUM AND DATUM CONVERSION INFORMATION | | | (NAVD 88 AND NGVD 29). | | | 10. PROVIDE CCTV VIDEO OF EXISTING SANITARY SEWER AND | | | STORMWATER ALONG ENTIRE PROJECT FRONTAGE. | | | 11. PLEASE PROVIDE CALCULATIONS OF REVISED PERVIOUS AND | | | IMPERVIOUS CALCULATIONS FOR THE PROPOSED IMPACTED | | | AREAS. | | | 12. PROVIDE ONSITE CLEANOUTS NEAR PROPERTY LINE FOR | | | PROPOSED SANITARY LATERALS. | | | 13. PLEASE LABEL WATER LINES AS PRIVATE WHERE | | | APPLICABLE. | | | 14. PLEASE PROVIDE ENLARGED VIEW ON PLANS OF PROPOSED | | | LOCATION OF WATER METER AND BACKFLOW PREVENTION. | | | 15. COORDINATE WITH MARK HURLEY, FIELD CUSTOMER SERVICE | | | SUPERVISOR WITH CITY OF WPB PUBLIC UTILITIES, REGARDING | | | PLACEMENT OF BACKFLOW DEVICES AND WATER METERS. CONTACT | | | HIM AT 561-494-2262 OR [email protected] | | | 16. PROVIDE DEDICATED UTILITY EASEMENTS TO ALLOW ACCESS | | | FOR CITY PERSONNEL TO PROPOSED UTILITY WATER METERS. | | | | | | FEEL FREE TO CONTACT US IF YOU HAVE ANY QUESTIONS OR | | | CONCERNS, THANKS. | | | RICK ROSSANO, PROJECT COORDINATOR, ENGINEERING SERVICES | | | DEPARTMENT, (561) 494-1098 [email protected] | | | | | | THE FOLLOWING COMMENTS ARE FROM MARK HURLEY, FIELD | | | CUSTOMER SERVICE SUPERVISOR, WPB PUBLIC UTILITIES, | | | PLEASE CONTACT 561-494-2262 OR [email protected]: | | | COMMENTS AS FOLLOWS: | | | -WILL THE EXISTING DOCK REMAIN, OR WILL IT BE REMOVED? | | | -PLEASE SUBMIT DEMOLITION PLAN IF THERE WILL BE | | | DEMOLITION. | | | -ON THE WATER PLAN, PLEASE SHOW THE LARGE WATER MAIN | | | THAT IS NEAR THE LENGTH OF THE SOUTHERN PROPERTY LINE. | | | -WILL THERE BE A STRUCTURE WITH WALLS AROUND THE | | | DUMPSTER? | | | -PLEASE SHOW ALL EXISTING WATER SERVICES, METERS, AND | | | BACKFLOW ASSEMBLIES ON THE WATER PLAN AND LABEL WHAT IS | | | HAPPENING TO THEM. | | | -LABEL THE EXISTING WATER & SEWER MAINS WITH PIPE SIZE | | | AND MATERIAL TYPE. | | | -WATER PLAN IS MISSING WATER DEMAND CALCULATIONS. | | | PLEASE ADD. | | | -SHOW AND LABEL ALL UTILITY POLES NEAR THE WEST | | | PROPERTY LINE ON THE CIVIL PLANS. | | | -SHOW AND LABEL THE NEAREST FIRE HYDRANT TO FDC ON THE | | | WATER PLAN. | | | -ARE THERE ANY EXISTING OR PROPOSED WELLS ON SITE? | | | -WILL A SEPARATE METERED IRRIGATION WATER SERVICE BE | | | NEEDED? | | | -LABEL OBJECT ON SITE PLAN THAT IS ABOUT 10 FEET SOUTH | | | OF THE NORTHWEST CORNER OF PROPERTY. | | | -VERIFY TREES ARE ALLOWED TO BE INSTALLED IN FPL | | | EASEMENT. | | | -THERE APPEARS TO BE A TREE CONFLICT WITH UTILITY POLE | | | NEAR SOUTHWEST CORNER OF PROPERTY. | | | -DOMESTIC WATER METER IS NOT SHOWN ON WATER PLAN. | | | PLEASE SHOW AND LABEL NEAR THE WEST PROPERTY LINE. | | | -IF DOMESTIC WATER METER IS 3 INCHES OR LARGER, IT | | | NEEDS TO BE INSTALLED ABOVE-GROUND. | | | -SOME TREES NEAR SOUTH PROPERTY LINE MAY CONFLICT WITH | | | WATER UTILITIES, ESPECIALLY THE WATER MAIN RUNNING WEST | | | TO EAST FOR THE NEIGHBORING PROPERTY. | | | -TREES NEAR NORTH PROPERTY LINE MAY CREATE MAINTENANCE | | | PROBLEM FOR THE PRIVATE FIRELINE PIPING. | | | -PROPERTY OWNER WOULD HAVE TO SUBMIT AND RECORD A | | | BACKFLOW COVENANT. | | | -DOMESTIC BACKFLOW ASSEMBLY NEEDS TO BE LOCATED | | | ADJACENT TO THE DOMESTIC WATER METER NEAR THE WESTERN | | | PROPERTY LINE. | | | -LOCATION OF PRIVATE WATER UTILITY PIPING UNDER | | | DUMPSTER AREA MAY CREATE MAINTENANCE CONFLICT FOR | | | PROPERTY OWNER. | | | -SHOW GATE VALVE FOR DOMESTIC WATER SERVICE IF IT WILL | | | BE LARGER THAN 2 INCHES. TRY TO LOCATE IT OUT OF THE | | | SIDEWALK. | | | -SHOW ALL EXISTING SEWER LATERALS FOR THE PROPERTY AND | | | WHAT IS HAPPENING TO THEM. | | | -UTILITY WORK IN STREET MAY REQUIRE PAVEMENT | | | RESTORATION OF FLAGLER DRIVE. | | | -CONSIDER INSTALLING PARALLEL/DUAL BACKFLOW ASSEMBLIES | | | FOR THE DOMESTIC WATER SERVICE TO MINIMIZE WATER | | | OUTAGES DURING BACKFLOW MAINTENANCE. | | | | | | RESPECTFULLY, | | | | | | MARK HURLEY | | | FIELD CUSTOMER SERVICE SUPERVISOR | | | CITY OF WEST PALM BEACH PUBLIC UTILITIES | | | 561-822-2262 | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
10-06-2021 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
10-06-2021 |
Time |
15:27 |
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
10-06-2021 |
Time |
15:17 |
Sent To |
|
|
| Notes |
| 2021-10-06 15:28:08 | FIRE HAS NO OBJECTIONS TO THE PROPOSED AND APPROVES. | | | | | | FIRE'S APPROVAL OF THIS SUBMITTED PROJECT DOES NOT | | | CONSTITUTE IT'S FINAL REVIEW OR APPROVAL. | | | | | | FIRE SHALL REVIEW ALL SUBMITTED BUILDING PLANS AT THE | | | APPROPRIATE TIME AND IN ACCORDANCE WITH THE | | | REQUIREMENTS OF ALL APPLICABLE CODES AND STANDARDS. | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
06-09-2021 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
06-09-2021 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
06-09-2021 |
Time |
13:31 |
Sent To |
|
|
| Notes |
| 2021-06-09 13:52:48 | THE FOLLOWING COMMENTS WERE SUBMITTED BY PETER LEDUC, | | | FIRE MARSHAL, BUREAU OF FIRE PREVENTION, WEST PALM | | | BEACH FIRE RESCUE. | | | | | | THIS REVIEW CAN ONLY BE CONSIDERED PRELIMINARY AS THE | | | DRAWINGS THAT WERE REVIEWED WERE NOT COMPLETE. | | | ADDITIONAL COMMENTS CAN BE EXPECTED WHEN FULL DRAWINGS | | | ARE SUBMITTED FOR PERMIT. | | | | | | THE FIRE PREVENTION BUREAU HAS NO OBJECTIONS TO THE | | | PROPOSED PROJECT; HOWEVER, THE FOLLOWING COMMENTS ARE | | | PROVIDED AND MAY NEED FURTHER CLARIFICATIONS WHERE | | | APPLICABLE. | | | | | | 1. CONSTRUCTION, DEMOLITION, AND RENOVATION TO COMPLY | | | WITH NFPA 241. EXTRA ATTENTION SHALL BE GIVEN TO THE | | | PERMITTING AND LOCATION OF CONSTRUCTION TRAILERS. A | | | PERMIT IS REQUIRED FOR ANY CONSTRUCTION TRAILER RELATED | | | TO THIS PROJECT. SEPARATION DISTANCES FROM MAIN | | | STRUCTURES AS WELL AS OTHER TRAILERS SHALL BE CLOSELY | | | MONITORED FOR THE REQUIREMENTS OF FIRE SPRINKLER | | | PROTECTION. | | | | | | 2. SITE ACCESS AND EXIT POINTS ARE TO BE CLEARLY | | | IDENTIFIED AND MAINTAINED FOR EMERGENCY VEHICLES DURING | | | ALL CONSTRUCTION ACTIVITIES. | | | | | | 3. THE BUILDING ADDRESS SHALL BE CLEARLY VISIBLE FROM | | | ALL ACCESS ROADWAYS, INCLUDING DURING CONSTRUCTION. | | | ADDRESS NUMBERS SHALL CONTRAST WITH THEIR BACKGROUND | | | AND SHALL NOT BE LESS THAN SIX (6) INCHES IN HEIGHT | | | WITH A ONE (1) INCH STROKE FOR ALL BUILDINGS. | | | | | | 4. DURING CONSTRUCTION, TRASH AND DEBRIS IS TO BE | | | REMOVED FROM THE SITE DAILY OR MORE OFTEN TO REDUCE THE | | | ACCUMULATION OF POTENTIAL LIFE AND FIRE SAFETY HAZARDS. | | | | | | 5. THE CONSTRUCTION OF THE BUILDING SHALL COMPLY WITH | | | THE 7TH EDITION OF THE FLORIDA FIRE PREVENTION CODE, | | | INCLUDING NFPA 1 & 101, AND ALL ASSOCIATED FIRE CODES. | | | | | | 6. ALL PARKING STRUCTURES SHALL COMPLY WITH NFPA 88A, | | | PARKING STRUCTURES AND NFPA 101, THE LIFE SAFETY CODE, | | | INCLUDING MORE SPECIFICALLY, CHAPTER 42 STORAGE | | | OCCUPANCIES (PARKING STRUCTURES) | | | | | | 7. A NFPA 13 COMPLAINT FIRE SPRINKLER SYSTEM AND NFPA | | | 14 COMPLIANT WET STANDPIPE SYSTEM ARE REQUIRED FOR THIS | | | STRUCTURE. TEMPORARY STANDPIPES ARE REQUIRED WHEN THE | | | BUILDING REACHES THREE LEVELS OR THIRTY FEET WHILE | | | BEING CONSTRUCTED. SEPARATE SHOP DRAWINGS, ARE REQUIRED | | | TO BE SUBMITTED, REVIEWED AND APPROVED BY THE FIRE | | | PREVENTION BUREAU PRIOR TO ANY INSTALLATION. | | | IT IS RECOMMENDED FOR HIGH RISES HAVE TWO SEPARATE FDC | | | LOCATIONS REMOTELY LOCATED. | | | | | | 7A. PER NFPA 14 | | | 6.4.5.4* FIRE DEPARTMENT CONNECTIONS SHALL BE LOCATED | | | NOT MORE THAN 100 FT (30.5 M) FROM THE NEAREST FIRE | | | HYDRANT CONNECTED TO AN APPROVED WATER SUPPLY. | | | | | | 7B. PER NFPA 1 | | | 18.3 WATER SUPPLIES. | | | 18.3.1* AN APPROVED WATER SUPPLY CAPABLE OF SUPPLYING | | | THE REQUIRED FIRE FLOW FOR FIRE PROTECTION SHALL BE | | | PROVIDED TO ALL PREMISES UPON WHICH FACILITIES, | | | BUILDINGS, OR PORTIONS OF BUILDINGS ARE HEREAFTER | | | CONSTRUCTED OR MOVED INTO THE JURISDICTION. THE | | | APPROVED WATER SUPPLY SHALL BE IN ACCORDANCE WITH | | | SECTION 18.4. | | | PER FLORIDA ADMINISTRATIVE CODE SECTION 61G15-32.004, | | | FIRE PROTECTION ENGINEERING DOCUMENTS SHALL INCLUDE THE | | | POINT OF SERVICE FOR THE WATER SUPPLY, A LIST OF | | | APPLICABLE NFPA STANDARDS APPLICABLE TO THE PROJECT, | | | CLASSIFICATION OF HAZARD OCCUPANCY FOR EACH ROOM OR | | | AREA, SUPPRESSION SYSTEM TYPE, DESIGN DENSITIES, WATER | | | SUPPLY DATA (FIRE PUMP DATA, HYDRANT FLOW TEST DATA) | | | AND ANY PERFORMANCE BASED INFORMATION SUCH AS | | | PRE-ENGINEERED SYSTEMS. | | | FOR THE PROPOSED FIRE PUMP(S) , WHAT IS(ARE) THE | | | PRIMARY AND SECONDARY POWER SOURCES? | | | | | | 7C. THE LOCATION OF THE DDCV FIRE LINE LOCATION SHALL | | | MEET THE REQUIREMENTS OF NFPA 24 AND SHALL BE | | | COORDINATED WITH THE OFFICE OF FIRE MARSHAL, THE CITY'S | | | ENGINEERS OFFICE, THE LANDSCAPE PLANNER, AND THE CITY'S | | | PLANNING AND ZONING OFFICE. | | | | | | 7D. THERE IS AN INDICATION OF A BOAT DOCK EXTINDING | | | INTO THE INTRACOASTAL WATERWAY. | | | | | | IT SHALL COMPLY WITH THE REQUIRMENTS OF THE 2016 ED | | | NFPA 303, FIRE PROTECTION STANDARD FOR MARINAS AND | | | BOATYARDS, WHICH MAY REQUIRE A FIRE HYDRANT, FDC AND | | | STANDPIPE SYSTEM. | | | | | | | | | 8. A CLASS ?A? NFPA 72 COMPLIANT MONITORED FIRE ALARM | | | SYSTEM IS REQUIRED FOR THIS STRUCTURE. SEPARATE SHOP | | | DRAWINGS, ARE REQUIRED TO BE SUBMITTED, REVIEWED AND | | | APPROVED BY THE FIRE PREVENTION BUREAU PRIOR TO ANY | | | INSTALLATION. | | | | | | 9. ALL ELEVATORS SHALL BE EQUIPPED WITH A REGION 7 | | | KEYWAY SYSTEM. | | | | | | ALL NEW ELEVATORS SHALL CONFORM TO THE FIRE FIGHTER?S | | | EMERGENCY OPERATIONS REQUIREMENTS OF ASME A17.1/CSA | | | B44, SAFETY CODE FOR ELEVATORS. | | | ANY BUILDING THAT IS MORE THAN THREE STORIES HIGH OR IN | | | WHICH THE VERTICAL DISTANCE BETWEEN THE BOTTOM TERMINAL | | | LANDING AND THE TOP TERMINAL LANDING EXCEEDS 25 FEET | | | MUST BE CONSTRUCTED TO CONTAIN AT LEAST ONE PASSENGER | | | ELEVATOR THAT IS OPERATIONAL AND WILL ACCOMMODATE AN | | | AMBULANCE STRETCHER 76 INCHES LONG AND 24 INCHES WIDE | | | IN THE HORIZONTAL POSITION. | | | | | | 10. COMPLETE LIFE SAFETY PLANS FOR EACH OCCUPANCY SHALL | | | BE PROVIDED THAT ILLUSTRATE OCCUPANT LOADS, TRAVEL | | | DISTANCES, COMMON PATHS OF TRAVEL, DEAD-END CORRIDORS, | | | EXIT SIGNS, EMERGENCY LIGHTING, EXITS LEADING TO A | | | PUBLIC WAY, FIRE EXTINGUISHER LOCATIONS, AND ALL FIRE | | | SAFETY FEATURES AND EQUIPMENT. | | | | | | 11. ALL EXISTING AND NEW FIRE HYDRANTS PLANNED FOR THIS | | | DEVELOPMENT SHALL BE CLEARLY INDICATED AND IDENTIFIED | | | ON THE PLAN AND CLOSELY COORDINATED WITH THE BUREAU OF | | | FIRE PREVENTION. | | | ALL NEW FIRE HYDRANTS AND FDC?S PLANNED FOR THIS | | | DEVELOPMENT SHALL BE CLOSELY COORDINATED WITH THE | | | BUREAU OF FIRE PREVENTION. PROPOSED FIRE HYDRANTS AND | | | FDC?S SHOULD BE LOCATED ON THE SAME SIDE OF THE STREET | | | OR ACCESS ROADWAY TO ALLOW FREE ACCESS FOR OTHER | | | ARRIVING EMERGENCY VEHICLES. | | | | | | 12. COMMAND ROOM : THE ROOM IS LOCATED WITHIN THE | | | CENTER OF THE BUILDING. THE ROOM LOCATION IS REQUIRED | | | TO BE LOCATED PER THE AHJ. CAN THE ROOM BE | | | RELOCATED/SWITCHED TO AN EXTERIOR WALL WITH ACCESS FROM | | | THE EXTERIOR WALL..I.E THE EMPLOYEE LOUNGE OR DOM W | | | PUMP ROOM? | | | THE FIRE COMMAND CENTER SHALL COMPLY WITH NFPA 1, | | | CHAPTER 11, BUILDING SERVICES; 11.9 AND SHALL CONTAIN | | | THE FOLLOWING FEATURES: | | | | | | 11.9.1 THE LOCATION, DESIGN, CONTENT, AND FIRE | | | DEPARTMENT ACCESS OF THE EMERGENCY COMMAND CENTER SHALL | | | BE APPROVED BY THE FIRE DEPARTMENT. | | | | | | 11.9.2 THE EMERGENCY COMMAND CENTER SHALL BE SEPARATED | | | FROM THE REMAINDER OF THE BUILDING BY A FIRE BARRIER | | | HAVING A FIRE RESISTANCE RATING OF NOT LESS THAN 1 | | | HOUR. | | | | | | 11.9.3 THE EMERGENCY COMMAND CENTER ROOM SHALL BE A | | | MINIMUM OF 96 FT2 (8.9 M2) WITH A MINIMUM DIMENSION OF | | | 8 FT (2.4 M). | | | | | | A. PER FL BLDG CODE;(MORE STRICT) IT SHALL BE A MINIMUM | | | OF 200 FT SQUARED WITH A MINIMUM DIMENSION OF 10 FT. | | | B. THE FIRE DEPARTMENT COMMUNICATIONS SYSTEM. | | | C. A TELEPHONE FOR FIRE DEPARTMENT USE WITH CONTROLLED | | | ACCESS TO THE PUBLIC TELEPHONE SYSTEM | | | D. SCHEMATIC BUILDING PLANS INDICATING THE TYPICAL | | | FLOOR PLAN AND DETAILING THE BUILDING CORE, MEANS OF | | | EGRESS, FIRE PROTECTION SYSTEMS, FIRE-FIGHTING | | | EQUIPMENT AND FIRE DEPARTMENT ACCESS AND THE LOCATION | | | OF FIRE WALLS, FIRE BARRIERS, FIRE PARTITIONS, SMOKE | | | BARRIERS AND SMOKE PARTITIONS | | | E. A WORK TABLE. | | | F. IF APPLICABLE, A HAZARDOUS MATERIAL MANAGEMENT PLAN | | | FOR THE BUILDING. | | | G. THE EMERGENCY VOICE/ALARM COMMUNICATION SYSTEM | | | CONTROL UNIT. | | | H. ANNUNCIATOR UNIT VISUALLY INDICATING THE LOCATION OF | | | THE ELEVATORS AND WHETHER THEY ARE OPERATIONAL | | | I. STATUS INDICATORS AND CONTROLS FOR AIR DISTRIBUTION | | | SYSTEMS. | | | J. CONTROLS FOR UNLOCKING STAIRWAY DOORS SIMULTANEOUSLY | | | K. SPRINKLER VALVE AND WATER FLOW DETECTOR DISPLAY | | | PANELS | | | L. EMERGENCY AND STANDBY POWER STATUS INDICATORS | | | M. FIRE PUMP STATUS INDICATORS | | | N. GENERATOR SUPERVISION DEVICES AND MANUAL START AND | | | TRANSFER FEATURES. | | | O. PUBLIC ADDRESS SYSTEM, WHERE SPECIFICALLY REQUIRED | | | BY OTHER SECTIONS OF THIS CODE | | | P. CONTROLS REQUIRED FOR SMOKE CONTROL | | | Q. ELEVATOR FIRE RECALL SWITCH IN ACCORDANCE WITH ASME | | | A17.1. | | | R. ELEVATOR EMERGENCY OR STANDBY POWER SELECTOR | | | SWITCH(ES), WHERE EMERGENCY OR STANDBY POWER IS | | | PROVIDED | | | 11.8.6* EMERGENCY COMMAND CENTER. | | | 11.8.6.1 AN EMERGENCY COMMAND CENTER SHALL BE PROVIDED | | | IN A | | | LOCATION APPROVED BY THE FIRE DEPARTMENT. | | | 11.8.6.2 THE EMERGENCY COMMAND CENTER SHALL CONTAIN THE | | | FOLLOWING: | | | (1) VOICE FIRE ALARM SYSTEM PANELS AND CONTROLS | | | (2) FIRE DEPARTMENT TWO-WAY TELEPHONE COMMUNICATION | | | SERVICE | | | PANELS AND CONTROLS WHERE REQUIRED BY ANOTHER SECTION | | | OF THIS | | | CODE | | | (3) FIRE DETECTION AND FIRE ALARM SYSTEM ANNUNCIATION | | | PANELS | | | (4) ELEVATOR FLOOR LOCATION AND OPERATION ANNUNCIATORS | | | (5) ELEVATOR FIRE RECALL SWITCH IN ACCORDANCE WITH ASME | | | A17.1/CSA B44, SAFETY CODE FOR ELEVATORS AND ESCALATORS | | | (6) ELEVATOR EMERGENCY POWER SELECTOR SWITCH(ES) WHERE | | | PROVIDED | | | IN ACCORDANCE WITH ASME A17.1/CSA B44 | | | (7) SPRINKLER VALVE AND WATERFLOW ANNUNCIATORS | | | (8) EMERGENCY GENERATOR STATUS INDICATORS | | | (9) CONTROLS FOR ANY AUTOMATIC STAIRWAY DOOR UNLOCKING | | | SYSTEM | | | (10) FIRE PUMP STATUS INDICATORS | | | (11) TELEPHONE FOR FIRE DEPARTMENT USE WITH CONTROLLED | | | ACCESS TO THE | | | PUBLIC TELEPHONE SYSTEM | | | (12) STAIRWAY VIDEO MONITORING EQUIPMENT AS REQUIRED BY | | | 11.8.8 | | | | | | 13. TWO-WAY RADIO ENHANCEMENT | | | | | | NFPA 1, CHAPTER 11, BUILDING SERVICES; 11.10 TWO-WAY | | | RADIO ENHANCEMENT SERVICES. | | | 11.10.1 IN ALL NEW AND EXISTING BUILDINGS, MINIMUM | | | RADIO SIGNAL STRENGTH FOR FIRE DEPARTMENT | | | COMMUNICATIONS SHALL BE MAINTAINED AT A LEVEL | | | DETERMINED BY THE AHJ. | | | NFPA 72, 24.5.2* TWO-WAY RADIO COMMUNICATIONS | | | ENHANCEMENT SYSTEMS. | | | 24.5.2.2 RADIO COVERAGE. RADIO COVERAGE SHALL BE | | | PROVIDED THROUGHOUT THE BUILDING AS A PERCENTAGE OF | | | FLOOR AREA AS SPECIFIED IN 24.5.2.2.1 THROUGH | | | 24.5.2.2.3. | | | 24.5.2.2.1 CRITICAL AREAS. CRITICAL AREAS, SUCH AS THE | | | EMERGENCY COMMAND CENTER(S), THE FIRE PUMP ROOM(S), | | | EXIT STAIRS, EXIT PASSAGEWAYS, ELEVATOR LOBBIES, | | | STANDPIPE CABINETS, SPRINKLER SECTIONAL VALVE | | | LOCATIONS, AND OTHER AREAS DEEMED CRITICAL BY THE | | | AUTHORITY HAVING JURISDICTION, SHALL BE PROVIDED WITH | | | 99 PERCENT FLOOR AREA RADIO COVERAGE. | | | 24.5.2.2.2 GENERAL BUILDING AREAS. GENERAL BUILDING | | | AREAS SHALL BE PROVIDED WITH 90 PERCENT FLOOR AREA | | | RADIO COVERAGE. | | | 24.5.2.3 SIGNAL STRENGTH. | | | 24.5.2.3.1 INBOUND. A MINIMUM INBOUND SIGNAL STRENGTH | | | OF -95 DBM, OR OTHER SIGNAL STRENGTH AS REQUIRED BY THE | | | AUTHORITY HAVING JURISDICTION, SHALL BE PROVIDED | | | THROUGHOUT THE COVERAGE AREA. | | | 24.5.2.3.2 OUTBOUND. A MINIMUM OUTBOUND SIGNAL STRENGTH | | | OF -95 DBM AT THE DONOR SITE, OR OTHER SIGNAL STRENGTH | | | AS REQUIRED BY THE AUTHORITY HAVING JURISDICTION, SHALL | | | BE PROVIDED FROM THE COVERAGE AREA. | | | | | | THE SYSTEM SHALL MAINTAIN A MINIMUM RADIO SIGNAL | | | STRENGTH USED BY WEST PALM BEACH FIRE RESCUE. TESTING | | | SHALL BE BY AN ACCEPTABLE NATIONAL STANDARD DOCUMENTING | | | PERCENTAGES NOTED ABOVE AND BY ACTUAL RADIO TESTING BY | | | FIRE PERSONNEL. IF THE MINIMUM CANNOT BE MAINTAINED, A | | | BI-DIRECTIONAL AMPLIFIED SYSTEM SHALL BE INSTALLED WITH | | | A MINIMUM 2-HOUR RUN TIME BATTERY BACK-UP. | | | | | | PLEASE CONTACT MARK FILLA, PALM BEACH COUNTY PUBLIC | | | SAFETY RADIO SYSTEMS MANAGER, [email protected], | | | 561-233-0837; AS OUR RADIOS OPERATE ON THEIR SYSTEM FOR | | | DETAILED RADIO FREQUENCY AND INSTALLATION INSTRUCTIONS. | | | | | | | | | 14. KNOX-BOX KEY SYSTEM SHALL BE REQUIRED FOR THIS | | | BUILDING LOCATED AS DIRECTED BY THE AHJ, | | | | | | ANY GATES SHALL BE PROVIDED WITH KNOX KEY ACCESS LOCKS, | | | PADLOCKS AND/OR SWITCHES FOR 24 HOUR EMERGENCY ACCESS. | | | | | | 15. THE SMOKE CONTROL SYSTEM SHALL COMPLY WITH NFPA | | | 101, CHAPTER 9, BUILDING SERVICE AND FIRE PROTECTION | | | EQUIPMENT, INCLUDING: | | | | | | THE SMOKE CONTROL SYSTEMS SHALL BE INSTALLED, | | | INSPECTED, TESTED, AND MAINTAINED IN ACCORDANCE WITH | | | NFPA 92, STANDARD FOR SMOKE CONTROL SYSTEMS; NFPA 204, | | | STANDARD FOR SMOKE AND HEAT VENTING; OR NATIONALLY | | | RECOGNIZED STANDARDS, ENGINEERING GUIDES, OR | | | RECOMMENDED PRACTICES, AS APPROVED BY THE AUTHORITY | | | HAVING JURISDICTION. | | | THE ENGINEER OF RECORD SHALL CLEARLY IDENTIFY THE | | | INTENT OF THE SYSTEM, THE DESIGN METHOD USED, THE | | | APPROPRIATENESS OF THE METHOD USED, AND THE REQUIRED | | | MEANS OF INSPECTING, TESTING, AND MAINTAINING THE | | | SYSTEM. | | | ACCEPTANCE TESTING SHALL BE PERFORMED BY A SPECIAL | | | INSPECTOR IN ACCORDANCE WITH SECTION 9.9. | | | | | | 16. THE BUREAU'S APPROVAL OF THIS SUBMITTED PROJECT | | | DOES NOT CONSTITUTE IT'S FINAL REVIEW OR APPROVAL. | | | | | | 17. THE BUREAU SHALL REVIEW ALL SUBMITTED BUILDING | | | PLANS AT THE APPROPRIATE TIME AND IN ACCORDANCE WITH | | | THE REQUIREMENTS OF ALL APPLICABLE CODES AND STANDARDS. | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
3 |
Status |
P |
Date |
11-10-2021 |
|
|
Cont ID |
|
| Sent By |
rcaranci |
Date |
11-10-2021 |
Time |
12:10 |
Rev Time |
0.00 |
| Received By |
rcaranci |
Date |
11-10-2021 |
Time |
12:10 |
Sent To |
|
|
| Notes |
| 2021-11-10 12:10:44 | FROM: RAY CARANCI, LANDSCAPE PLANNER 561-822-1462 | | | PROJECT: SCUBA CLUB RPD Z21050010 | | | NOVEMBER 10, 2021 | | | | | | ANDREW BURNETT LANDSCAPE PLANNER 6/17/21 | | | 561-822-1562 | | | | | | 1. SATISFIED. UNABLE TO SEE MEASUREMENTS OF LANDSCAPE | | | BUFFER ON SOUTH SIDE IS REQUIRED SIZE. COULD NOT | | | VERIFIED DIMENSIONS OF BUFFER. ALL LANDSCAPE BUFFERS | | | SHALL BE A MINIMUM OF FIVE FEET WIDE. | | | 94-443 2 .A. | | | 2. SATISFIED. INCORPORATE SHADE TREES MISSING FROM WEST | | | SIDE LANDSCAPE BUFFER. | | | AT LEAST ONE SHADE OR FLOWERING TREE SHALL BE PLANTED | | | IN A REQUIRED BUFFER FOR EACH 30 LINEAR FEET OR PORTION | | | THEREOF. REQUIRED SHADE OR FLOWERING TREES MAY BE | | | PLANTED AT INTERVALS OR MAY BE CLUSTERED IF CLUSTERING | | | IMPROVES THE EFFECTIVENESS OF THE BUFFER. REQUIRED | | | TREES TO SERVE AS A LANDSCAPE BUFFER ADJACENT TO A | | | RESIDENTIAL ZONING DISTRICT MUST BE VISIBLE FROM THE | | | OPPOSITE SIDE OF THE WALL TO ENHANCE THE BUFFERING | | | EFFECT. CLUSTERING OF REQUIRED TREES SHALL BE SUBJECT | | | TO CITY APPROVAL. IF THERE IS ADDITIONAL LANDSCAPE AREA | | | ADJACENT TO THE BUFFER STRIP, REQUIRED TREES MAY BE | | | PLACED ADJACENT TO THE BUFFER STRIP TO ALLOW A GREATER | | | AREA FOR TREE DEVELOPMENT. 94-443 2. C | | | | | | 3. SATISFIED. MINIMUM TREE SIZES ARE 12 FEET HEIGHT, | | | CORRECT ON PLANT LIST. AMENITY DECK LIGUSTRUM TREES ARE | | | REQUIRED AT 12 FEET HEIGHT. TREES ARE PROHIBITED FROM | | | BEING TRIMMED INTO SHAPES AND MUST BE ALLOWED TO | | | DEVELOP INTO THEIR MATURE SIZE TO FULFILL THE CODE | | | REQUIREMENTS. PROVIDE REASON FOR SMALLER SIZES | | | | | | | | | 4. CONDITIONALLY SATISFIED. HEDGE MUST BE PROVIDED ON | | | THE 3 NON ACCESS SIDES OF THE DUMPSTER ENCLOSURE. | | | STAFF SUGGESTS THE ENCLOSURE BE REORIENTED TO ALLOW | | | COMPLIANCE WITH THE REQUIREMENT. | | | | | | 5. SATISFIED. PROVIDE SCREENING FOR ALL GROUND MOUNTED | | | VALVES AND EQUIPMENT. LOCATION OF BACKFLOWS | | | TRANSFORMERS COULD NOT BE FOUND IN PLAN. | | | | | | | | | 6. SATISFIED. INDICATE ON TREE DISPOSITION LOCATION OF | | | #31 SEAGRAPE UNABLE TO LOCATION ON PLAN. | | | | | | | | | ADDITIONAL COMMENTS 10/14/21: | | | 6. SATISFIED. ISPR 15-06 CONTAINED AN APPROVED TREE | | | DISPOSITION PLAN SHEET TDP-1 DATED DECEMBER 2, 2015 | | | THAT SHOWED ADDITIONAL TREES AND PALMS ON THE SITE. IT | | | APPEARS SOME HAVE BEEN REMOVED WITH DEMOLITION ON THE | | | SITE. ADD ANY THAT WERE REMOVED TO THE CURRENT TREE | | | DISPOSITION PLAN AND SHOW AS REMOVED. | | | | | | 7. SATISFIED. BUFFER CALCULATIONS ON SHEET LP-3 NEED TO | | | BE CORRECTED FOR: | | | ? NORTH BUFFER TOTAL LENGTH 695 FT, 24 TREES REQUIRED, | | | 24 PROVIDED | | | ? SOUTH BUFFER TOTAL LENGTH 648 FEET, 22 TREES | | | REQUIRED, 27 PROVIDED | | | ? EAST BUFFER TOTAL LENGTH AT SEAWALL 100 FEET, 4 TREES | | | REQUIRED, 4 PROVIDED | | | | | | 8. SATISFIED. PER COMMENT 7 ABOVE THE WAIVER REQUEST | | | SHOULD BE MODIFIED TO INDICATE THE REQUIRED BUFFER IS | | | PROVIDED AT THE SEAWALL NOT AT THE PROPERTY LINE | | | BECAUSE OF SUBMERGED LAND. | | | | | | 9. SATISFIED. CORRECT THE OVERALL LANDSCAPE | | | REQUIREMENTS CHART ON SHEET LP-3: | | | ? SHADE TREES 21 ARE REQUIRED. | | | ? FLOWERING TREES 6 ARE REQUIRED | | | ? MOVE MULTIFAMILY TREE REQUIREMENT OF 55 TO THIS | | | CHART. | | | ? TOTAL TREES REQUIRED IS 82, QUALIFYING PROVIDED ON | | | PLANT LIST IS 41 TREES, 12 1:1 PALMS, 32 3:1 PALMS FOR | | | A TOTAL OF 63. | | | ? ADD RELOCATED PALMS TO PLANT LIST AND ADD TO | | | QUALIFYING PALMS. | | | ? REQUEST WAIVER IF THE TOTAL REQUIRED TREES CANNOT BE | | | MET. | | | | | | 10. SATISFIED. AFTER CORRECTIONS ARE MADE, RECALCULATE | | | FLORIDA FRIENDLY QUALIFYING POINTS. | | | | | | 11. SATISFIED. OFF SITE ROADWAY BEAUTIFICATION OF THE | | | ROAD RIGHT OF WAY IS REQUIRED, AND THE EXISTING | | | MAHOGANY TREE AND GREEN BUTTONWOOD TREE MUST BE | | | INCLUDED ON THE TREE DISPOSITION LIST. THE OFFSITE | | | TREES PROPOSED MUST BE SEPARATED ON THE PLANT LIST. | | | SHADE TREES ARE REQUIRED FOR PROVIDING SHADE FOR | | | PEDESTRIANS ON THE SIDEWALK. PROPOSE TREES APPROPRIATE | | | FOR THE SPACE INSTEAD OF COCONUT PALMS. | | | | | | CONDITIONS OF APPROVAL | | | 1. PRIOR TO THE REMOVAL OR RELOCATION OF ANY TREES ON | | | THE PROPERTY, A TREE ALTERATION PERMIT SHALL BE | | | SUBMITTED, REVIEWED AND APPROVED BY THE DEVELOPMENT | | | SERVICES DEPARTMENT, PLANNING DIVISION. TREES IN THE | | | RIGHT OF WAY ADJACENT TO THE PROPERTY MUST BE INCLUDED | | | IN THE PERMIT. | | | | | | 2. THE APPLICANT, SUCCESSORS AND ASSIGNS SHALL BE | | | RESPONSIBLE FOR THE PERMITTING AND INSTALLATION OF THE | | | STREET TREES AND RIGHT OF WAY LANDSCAPING AND | | | IRRIGATION APPROVED WITH THIS PETITION. | | | | | | 3. THE APPLICANT, SUCCESSORS AND ASSIGNS SHALL BE | | | RESPONSIBLE FOR THE MAINTENANCE OF THE ROAD RIGHT OF | | | WAY LANDSCAPING AND IRRIGATION. THIS WILL BE THROUGH A | | | SEPARATE MAINTENANCE AGREEMENT WITH THE CITY. | | | | | | 4. PRIOR TO SCHEDULING FOR CITY COMMISSION, THE | | | APPLICANT SHALL REDESIGN THE ENCLOSURE FOR THE DUMPSTER | | | TO MEET CODE REQUIREMENTS INCLUDING THE REQUIRED HEDGE | | | OR PROVIDE A MANAGEMENT PLAN FOR TRASH PICKUP. | | | |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
2 |
Status |
F |
Date |
10-14-2021 |
|
|
Cont ID |
|
| Sent By |
rcaranci |
Date |
10-14-2021 |
Time |
15:46 |
Rev Time |
0.00 |
| Received By |
rcaranci |
Date |
10-14-2021 |
Time |
15:45 |
Sent To |
|
|
| Notes |
| 2021-10-14 15:46:20 | FROM: RAY CARANCI, LANDSCAPE PLANNER 561-822-1462 | | | PROJECT: SCUBA CLUB RPD Z21050010 | | | OCTOBER 14, 2021 | | | | | | ANDREW BURNETT LANDSCAPE PLANNER 6/17/21 | | | 561-822-1562 | | | | | | 1. SATISFIED. UNABLE TO SEE MEASUREMENTS OF LANDSCAPE | | | BUFFER ON SOUTH SIDE IS REQUIRED SIZE. COULD NOT | | | VERIFIED DIMENSIONS OF BUFFER. ALL LANDSCAPE BUFFERS | | | SHALL BE A MINIMUM OF FIVE FEET WIDE. | | | 94-443 2 .A. | | | 2. SATISFIED. INCORPORATE SHADE TREES MISSING FROM WEST | | | SIDE LANDSCAPE BUFFER. | | | AT LEAST ONE SHADE OR FLOWERING TREE SHALL BE PLANTED | | | IN A REQUIRED BUFFER FOR EACH 30 LINEAR FEET OR PORTION | | | THEREOF. REQUIRED SHADE OR FLOWERING TREES MAY BE | | | PLANTED AT INTERVALS OR MAY BE CLUSTERED IF CLUSTERING | | | IMPROVES THE EFFECTIVENESS OF THE BUFFER. REQUIRED | | | TREES TO SERVE AS A LANDSCAPE BUFFER ADJACENT TO A | | | RESIDENTIAL ZONING DISTRICT MUST BE VISIBLE FROM THE | | | OPPOSITE SIDE OF THE WALL TO ENHANCE THE BUFFERING | | | EFFECT. CLUSTERING OF REQUIRED TREES SHALL BE SUBJECT | | | TO CITY APPROVAL. IF THERE IS ADDITIONAL LANDSCAPE AREA | | | ADJACENT TO THE BUFFER STRIP, REQUIRED TREES MAY BE | | | PLACED ADJACENT TO THE BUFFER STRIP TO ALLOW A GREATER | | | AREA FOR TREE DEVELOPMENT. 94-443 2. C | | | | | | 3. SATISFIED. MINIMUM TREE SIZES ARE 12 FEET HEIGHT, | | | CORRECT ON PLANT LIST. AMENITY DECK LIGUSTRUM TREES ARE | | | REQUIRED AT 12 FEET HEIGHT. TREES ARE PROHIBITED FROM | | | BEING TRIMMED INTO SHAPES AND MUST BE ALLOWED TO | | | DEVELOP INTO THEIR MATURE SIZE TO FULFILL THE CODE | | | REQUIREMENTS. PROVIDE REASON FOR SMALLER SIZES | | | | | | | | | 4. NOT SATISFIED HEDGE MUST BE PROVIDED ON THE 3 NON | | | ACCESS SIDES OF THE DUMPSTER ENCLOSURE. | | | STAFF SUGGESTS THE ENCLOSURE BE REORIENTED TO ALLOW | | | COMPLIANCE WITH THE REQUIREMENT. | | | | | | 5. SATISFIED. PROVIDE SCREENING FOR ALL GROUND MOUNTED | | | VALVES AND EQUIPMENT. LOCATION OF BACKFLOWS | | | TRANSFORMERS COULD NOT BE FOUND IN PLAN. | | | | | | | | | 6. SATISFIED. INDICATE ON TREE DISPOSITION LOCATION OF | | | #31 SEAGRAPE UNABLE TO LOCATION ON PLAN. | | | | | | | | | ADDITIONAL COMMENTS 10/14/21: | | | 6. ISPR 15-06 CONTAINED AN APPROVED TREE DISPOSITION | | | PLAN SHEET TDP-1 DATED DECEMBER 2, 2015 THAT SHOWED | | | ADDITIONAL TREES AND PALMS ON THE SITE. IT APPEARS SOME | | | HAVE BEEN REMOVED WITH DEMOLITION ON THE SITE. ADD ANY | | | THAT WERE REMOVED TO THE CURRENT TREE DISPOSITION PLAN | | | AND SHOW AS REMOVED. | | | | | | 7. BUFFER CALCULATIONS ON SHEET LP-3 NEED TO BE | | | CORRECTED FOR: | | | ? NORTH BUFFER TOTAL LENGTH 695 FT, 24 TREES REQUIRED, | | | 24 PROVIDED | | | ? SOUTH BUFFER TOTAL LENGTH 648 FEET, 22 TREES | | | REQUIRED, 27 PROVIDED | | | ? EAST BUFFER TOTAL LENGTH AT SEAWALL 100 FEET, 4 TREES | | | REQUIRED, 4 PROVIDED | | | | | | 8. PER COMMENT 7 ABOVE THE WAIVER REQUEST SHOULD BE | | | MODIFIED TO INDICATE THE REQUIRED BUFFER IS PROVIDED AT | | | THE SEAWALL NOT AT THE PROPERTY LINE BECAUSE OF | | | SUBMERGED LAND. | | | | | | 9. CORRECT THE OVERALL LANDSCAPE REQUIREMENTS CHART ON | | | SHEET LP-3: | | | ? SHADE TREES 21 ARE REQUIRED. | | | ? FLOWERING TREES 6 ARE REQUIRED | | | ? MOVE MULTIFAMILY TREE REQUIREMENT OF 55 TO THIS | | | CHART. | | | ? TOTAL TREES REQUIRED IS 82, QUALIFYING PROVIDED ON | | | PLANT LIST IS 41 TREES, 12 1:1 PALMS, 32 3:1 PALMS FOR | | | A TOTAL OF 63. | | | ? ADD RELOCATED PALMS TO PLANT LIST AND ADD TO | | | QUALIFYING PALMS. | | | ? REQUEST WAIVER IF THE TOTAL REQUIRED TREES CANNOT BE | | | MET. | | | | | | 10. AFTER CORRECTIONS ARE MADE, RECALCULATE FLORIDA | | | FRIENDLY QUALIFYING POINTS. | | | | | | 11. OFF SITE ROADWAY BEAUTIFICATION OF THE ROAD RIGHT | | | OF WAY IS REQUIRED, AND THE EXISTING MAHOGANY TREE AND | | | GREEN BUTTONWOOD TREE MUST BE INCLUDED ON THE TREE | | | DISPOSITION LIST. THE OFFSITE TREES PROPOSED MUST BE | | | SEPARATED ON THE PLANT LIST. SHADE TREES ARE REQUIRED | | | FOR PROVIDING SHADE FOR PEDESTRIANS ON THE SIDEWALK. | | | PROPOSE TREES APPROPRIATE FOR THE SPACE INSTEAD OF | | | COCONUT PALMS. | | | | | | CONDITIONS OF APPROVAL | | | 1. PRIOR TO THE REMOVAL OR RELOCATION OF ANY TREES ON | | | THE PROPERTY, A TREE ALTERATION PERMIT SHALL BE | | | SUBMITTED, REVIEWED AND APPROVED BY THE DEVELOPMENT | | | SERVICES DEPARTMENT, PLANNING DIVISION. TREES IN THE | | | RIGHT OF WAY ADJACENT TO THE PROPERTY MUST BE INCLUDED | | | IN THE PERMIT. | | | | | | 2. THE APPLICANT, SUCCESSORS AND ASSIGNS SHALL BE | | | RESPONSIBLE FOR THE PERMITTING AND INSTALLATION OF THE | | | STREET TREES AND RIGHT OF WAY LANDSCAPING AND | | | IRRIGATION APPROVED WITH THIS PETITION. | | | | | | 3. THE APPLICANT, SUCCESSORS AND ASSIGNS SHALL BE | | | RESPONSIBLE FOR THE MAINTENANCE OF THE ROAD RIGHT OF | | | WAY LANDSCAPING AND IRRIGATION. THIS WILL BE THROUGH A | | | SEPARATE MAINTENANCE AGREEMENT WITH THE CITY. | | | |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
1 |
Status |
F |
Date |
06-09-2021 |
|
|
Cont ID |
|
| Sent By |
aburnett |
Date |
06-09-2021 |
Time |
09:02 |
Rev Time |
0.00 |
| Received By |
aburnett |
Date |
06-09-2021 |
Time |
09:02 |
Sent To |
|
|
| Notes |
| 2021-06-09 09:04:52 | 1. UNABLE TO SEE MEASUREMENTS OF LANDSCAPE BUFFER ON | | | SOUTH SIDE IS REQUIRED SIZE. COULD NOT VERIFIED | | | DIMENSIONS OF BUFFER. ALL LANDSCAPE BUFFERS SHALL BE A | | | MINIMUM OF FIVE FEET WIDE. | | | 94-443 2 .A. | | | 2. INCORPORATE SHADE TREES MISSING FROM WEST SIDE | | | LANDSCAPE BUFFER. | | | AT LEAST ONE SHADE OR FLOWERING TREE SHALL BE PLANTED | | | IN A REQUIRED BUFFER FOR EACH 30 LINEAR FEET OR PORTION | | | THEREOF. REQUIRED SHADE OR FLOWERING TREES MAY BE | | | PLANTED AT INTERVALS OR MAY BE CLUSTERED IF CLUSTERING | | | IMPROVES THE EFFECTIVENESS OF THE BUFFER. REQUIRED | | | TREES TO SERVE AS A LANDSCAPE BUFFER ADJACENT TO A | | | RESIDENTIAL ZONING DISTRICT MUST BE VISIBLE FROM THE | | | OPPOSITE SIDE OF THE WALL TO ENHANCE THE BUFFERING | | | EFFECT. CLUSTERING OF REQUIRED TREES SHALL BE SUBJECT | | | TO CITY APPROVAL. IF THERE IS ADDITIONAL LANDSCAPE AREA | | | ADJACENT TO THE BUFFER STRIP, REQUIRED TREES MAY BE | | | PLACED ADJACENT TO THE BUFFER STRIP TO ALLOW A GREATER | | | AREA FOR TREE DEVELOPMENT. 94-443 2. C | | | | | | 3. MINIMUM TREE SIZES ARE 12 FEET HEIGHT, CORRECT ON | | | PLANT LIST. AMENITY DECK LIGUSTRUM TREES ARE REQUIRED | | | AT 12 FEET HEIGHT. TREES ARE PROHIBITED FROM BEING | | | TRIMMED INTO SHAPES AND MUST BE ALLOWED TO DEVELOP INTO | | | THEIR MATURE SIZE TO FULFILL THE CODE REQUIREMENTS. | | | PROVIDE REASON FOR SMALLER SIZES | | | | | | | | | 4. HEDGE MUST BE PROVIDED ON THE 3 NON ACCESS SIDES OF | | | THE DUMPSTER ENCLOSURE. | | | | | | 5. PROVIDE SCREENING FOR ALL GROUND MOUNTED VALVES AND | | | EQUIPMENT. LOCATION OF BACKFLOWS TRANSFORMERS COULD NOT | | | BE FOUND IN PLAN. | | | | | | | | | 6. INDICATE ON TREE DISPOSITION LOCATION OF #31 | | | SEAGRAPE UNABLE TO LOCATION ON PLAN. | | | | | | | | | FROM ANDREW BURNETT , LANDSCAPE PLANNDER 561-822-1562 | | | JUNE 9, 2021 |
|
|
| Review Stop |
PARK |
PARKING |
| Rev No |
1 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
|
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
POLICE |
POLICE |
| Rev No |
1 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
|
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
PW |
PUBLIC WORKS |
| Rev No |
2 |
Status |
P |
Date |
10-05-2021 |
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
| Received By |
|
Date |
10-05-2021 |
Time |
|
Sent To |
|
|
| Notes |
| 2021-10-05 14:58:11 | NO FURTHER COMMENTS. | | | | | | MATT HEJAZI | | | DEPT. OF PUBLIC WORKS | | | [email protected] | | | 822-2045 |
|
|
| Review Stop |
PW |
PUBLIC WORKS |
| Rev No |
1 |
Status |
F |
Date |
06-07-2021 |
|
|
Cont ID |
|
| Sent By |
|
Date |
06-07-2021 |
Time |
|
Rev Time |
|
| Received By |
|
Date |
06-07-2021 |
Time |
|
Sent To |
|
|
| Notes |
| 2021-06-07 11:21:00 | PLEASE PROVIDE LOS (LEVEL OF SERVICE ANALYSIS) TO | | | REFLECT THE SOLID WASTE VOLUME PRODUCED ALONG WITH THE | | | SIZE, TYPE AND QUANTITY OF THE CONTAINERS (I.E. | | | DUMPSTER/COMPACTOR) THAT WILL BE UTILIZED THAT WILL BE | | | UTILIZED FOR THE SANITATION SERVICE. | | | | | | MATT HEJAZI | | | DEPT. OF PUBLIC WORKS | | | [email protected] | | | 561-822-2045 | | | |
|
|
| Review Stop |
STORM |
STORMWATER |
| Rev No |
2 |
Status |
F |
Date |
10-15-2021 |
|
|
Cont ID |
|
| Sent By |
tward |
Date |
10-15-2021 |
Time |
04:33 |
Rev Time |
0.00 |
| Received By |
tward |
Date |
10-15-2021 |
Time |
04:33 |
Sent To |
|
|
| Notes |
| 2021-10-15 04:29:58 | THE FOLLOWING COMMENTS ARE FROM THE REVIEW OF THE | | | 10/4/2021 SUBMITTAL: | | | | | | 1. CONNECT ONSITE DRAINAGE SYSTEM TO THE EXISTING STORM | | | MANHOLE NEAR THE NORTH DRIVEWAY. | | | | | | 2. JUSTIFY THE SIZE OF THE OUTFALL DRAINAGE PIPE. | | | | | | 3. VERIFY THE CONTRIBUTION OF THE RUNOFF FROM THE | | | DEVELOPMENT WILL NOT NEGATIVELY IMPACT THE ROADWAY | | | DRAINAGE SYSTEM. | | | | | | 4. INFORMATION SHOWN FOR EXISTING DRAINAGE SYSTEM IN | | | THE ROAD APPEARS TO BE IN A DIFFERENT VERTICAL DATUM. | | | SUGGEST HAVING THE SURVEYOR OBTAIN FIELD MEASUREMENTS | | | OF RIM ELEVATIONS AND INVERT ELEVATIONS BECAUSE THE | | | CONVERSION FACTOR BETWEEN NAVD AND NGVD ON THE PLANS | | | WHEN APPLIED TO THE CITY'S AS-BUILTS FOR THE POINSETTIA | | | AVE PIPE REPLACEMENT PROJECT (PROJECT NO. 94441) DOES | | | NOT PROVIDE THE SAME ELEVATIONS SHOWN ON THE SURVEY. IT | | | COULD BE THE CITY'S AS-BUILTS DID NOT USE NGVD1929 AS | | | THE VERTICAL DATUM. | | | | | | 5. TREES PROPOSED OVER OR NEAR PROPOSED EXFILTRATION | | | TRENCH. SHOW PERIMETER SWALE ALONG NORTH AND SOUTH | | | PROPERTY LINES ON THE LANDSCAPE PLANS. | | | | | | 6. INDICATE IF THE EXISTING STREET LIGHT NEAR THE | | | PROPOSED NORTH DRIVEWAY WILL NEED TO BE RELOCATED. | | | | | | 7. SIGNING AND PAVEMENT MARKING: WILL ONE-WAY, DO NOT | | | ENTER OR ENTER/EXIT SIGNS BE NEEDED AT THE DRIVEWAY | | | ENTRANCES? | | | | | | 8. CONFIRM THE DESIGN INFORMATION OF THE CONTROL | | | STRUCTURE DETAIL. IT APPEARS TO BE FROM A DIFFERENT | | | PROJECT. | | | | | | 9. LIST THE VERTICAL DATUM REFERENCE AND CONVERSION TO | | | NGVD1929 ON ALL SHEETS WITH ELEVATION INFORMATION. | | | | | | 10. FOR SECTIONS A-A, B-B AND C-C: | | | A. CONTINUE THE 1.5% OR STEEPER SLOPE UP TO THE | | | PROPERTY LINE/RIGHT OF WAY LINE TO KEEP STORMWATER | | | RUNOFF FROM THE RIGHT OF WAY FROM FLOWING INTO THE | | | DEVELOPMENT. | | | B. CONFIRM THE GRADES FOR THE TRAVEL LANE AND THAT THE | | | ROAD HAS POSITIVE DRAINAGE TO A DRAINAGE STRUCTURE. | | | C. WHAT IS THE MINIMUM REQUIRED PERIMETER ELEVATION? | | | | | | 11. FOR SECTION D-D: | | | A. SHOW RETAINING WALL AND ELEVATION OF THE TOP OF THE | | | WALL. | | | B. SHOW DISTANCE FROM PROPERTY LINE TO FACE OF | | | BUILDING. | | | C. SHOW SIDEWALK AND DISTANCE FROM PROPERTY LINE TO | | | FRONT OF SIDEWALK. | | | | | | 12. EROSION CONTROL PLAN: | | | A. RELOCATE THE ROCKED CONSTRUCTION DRIVEWAY OUTSIDE OF | | | THE RIGHT OF WAY. | | | B. PROVIDE INLET PROTECTION FOR THE ROAD DRAINAGE | | | SYSTEM. | | | | | | | | | TRACY WARD, PE | | | SENIOR STORMWATER ENGINEER | | | ENGINEERING SERVICES DEPARTMENT | | | 561-494-1120 (O) | | | 561-351-0510 (M) | | | [email protected] |
|
|
| Review Stop |
STORM |
STORMWATER |
| Rev No |
1 |
Status |
F |
Date |
06-10-2021 |
|
|
Cont ID |
|
| Sent By |
tward |
Date |
06-10-2021 |
Time |
09:54 |
Rev Time |
0.00 |
| Received By |
tward |
Date |
06-10-2021 |
Time |
09:59 |
Sent To |
|
|
| Notes |
| 2021-06-10 09:55:12 | THIS IS A CONCEPTUAL LEVEL REVIEW. CONSTRUCTION LEVEL | | | DETAILS, DESIGN CALCULATIONS AND THE POLLUTION | | | PREVENTION PLAN WILL BE REVIEWED AS PART OF THE | | | ENGINEERING DEVELOPMENT APPROVAL AND BUILDING PERMIT | | | APPLICATION PROCESSES. | | | | | | THE FOLLOWING COMMENTS MUST BE ADDRESSED PRIOR TO SITE | | | PLAN APPROVAL: | | | | | | 1. PROJECT SITE IS WITHIN A SPECIAL FLOOD HAZARD AREA. | | | DRAFT COASTAL FLOOD ZONE MAPS HAVE BEEN ISSUED BY FEMA | | | THAT MAY SHOW A HIGHER BASE FLOOD ELEVATION THAN WHAT | | | IS SHOWN ON THE CURRENT FLOOD INSURANCE RATE MAPS. TWO | | | FEET OF FREEBOARD ABOVE THE BFE WILL BE REQUIRED FOR | | | THE FINISHED FLOOR ELEVATION AND ANY | | | MECHANICAL/ELECTRICAL EQUIPMENT. | | | | | | 2. PROPOSED EXFILTRATION TRENCH IS WITHIN FPL EASEMENT. | | | APPROVAL FROM FPL MAY BE NEEDED. | | | | | | 3. PROVIDE CROSS SECTIONS FOR EACH DRIVEWAY AND MIDWAY | | | BETWEEN DRIVEWAYS FROM CENTERLINE OF ROAD TO 10 FEET | | | WITHIN THE PROPERTY. | | | | | | 4. PROVIDE TYPICAL CROSS SECTIONS AT NORTH AND SOUTH | | | PROPERTY LINES FROM PROPERTY LINE TO FACE OF BUILDING. | | | | | | 5. PROPERTY CANNOT DRAIN ONTO ADJACENT PARCELS. | | | | | | 6. DRAINAGE SYSTEM TO BE DESIGNED TO MEET SFWMD ERP | | | CRITERIA AND CONSIDER SEA LEVEL RISE. THE DESIGN OF THE | | | EXFILTRATION TRENCH SHOULD CONSIDER THE IMPACTS THE | | | PERIMETER WALL AND THE BUILDING WILL HAVE ON THE FLOW | | | RATE OF THE EXFILTRATION TRENCH. | | | | | | 7. PROVIDE FLOW ARROWS ON THE PGD PLAN SHOWING | | | DIRECTION OF SURFACE RUNOFF. | | | | | | 8. CONSIDER SEA LEVEL RISE IN THE DESIGN OF THE | | | PROPOSED BULKHEAD. | | | | | | 9. CITY CODE PROHIBITS NEW DRAINAGE OUTFALLS INTO THE | | | LAKE WORTH LAGOON. | | | | | | 10. SHOW UTILITIES ON THE LANDSCAPE PLANS. | | | | | | 11. DECKING SHOWN ON THE CIVIL PLANS DOES NOT MATCH | | | WHAT IS SHOWN ON THE SITE PLAN. | | | | | | THE FOLLOWING COMMENTS MUST BE ADDRESSED PRIOR TO | | | ISSUANCE OF CONSTRUCTION AUTHORIZATION INCLUDING | | | BUILDING PERMITS AND ENGINEERING DEVELOPMENT APPROVAL. | | | | | | 1. AN ENGINEERING DEVELOPMENT APPROVAL APPLICATION MAY | | | BE REQUIRED FROM THE ENGINEERING SERVICES DEPARTMENT. | | | | | | 2. EROSION CONTROL PLAN AND DETAILS TO BE SUBMITTED | | | WITH THE ENGINEERING PERMIT APPLICATION. | | | | | | 3. PROVIDE COPY OF SFWMD ERP PERMIT(S) BEFORE START OF | | | CONSTRUCTION. | | | | | | 4. PROVIDE A COPY OF THE DRAINAGE CALCULATIONS WITH THE | | | ENGINEERING PERMIT APPLICATION. | | | | | | TRACY WARD, PE | | | SENIOR STORMWATER ENGINEER | | | ENGINEERING SERVICES DEPARTMENT | | | 561-494-1120 (O) | | | 561-351-0510 (M) | | | [email protected] | | | |
|
|
| Review Stop |
SURVEY |
SURVEYING |
| Rev No |
2 |
Status |
P |
Date |
10-14-2021 |
|
|
Cont ID |
|
| Sent By |
vnoel |
Date |
10-14-2021 |
Time |
07:12 |
Rev Time |
0.00 |
| Received By |
vnoel |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2021-10-14 07:14:09 | 1. NEED SIGNED COPY OF SURVEY. | | | 2. REPLAT AND UTILITY EASEMENT REQUIRED PRIOR TO CO. |
|
|
| Review Stop |
SURVEY |
SURVEYING |
| Rev No |
1 |
Status |
F |
Date |
06-07-2021 |
|
|
Cont ID |
|
| Sent By |
vnoel |
Date |
06-07-2021 |
Time |
08:08 |
Rev Time |
|
| Received By |
vnoel |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2021-06-07 08:18:09 | 1. REPLAT WILL BE REQUIRED. MINOR SUBDIVISION | | | APPLICATION IS MADE THROUGH PLANNING. | | | 2. FPL WILL NEED TO APPROVE TREES IN THEIR EASEMENT. | | | 3. MAINTENANCE AGREEMENT WILL BE REQUIRED FOR | | | IMPROVEMENTS IN FLAGLER DRIVE. | | | 4. WILL NEED SEPARATE APPLICATION FOR EXISTING DOCK | | | DEMOLITION AND NEW DOCK CONSTRUCTION. | | | 5. SEE ENGINEERING COMMENTS FOR WATER AND SEWER | | | HOOK-UPS. |
|
|
| Review Stop |
TRAFFIC |
TRAFFIC ENGINEERING |
| Rev No |
2 |
Status |
F |
Date |
10-15-2021 |
|
|
Cont ID |
|
| Sent By |
|
Date |
10-15-2021 |
Time |
|
Rev Time |
0.00 |
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2021-10-15 17:53:22 | 1) SATISFIED. PROVIDE COUNTY TPS LETTER | | | 2) NOT SATISFIED. AUTOTURN SHOWS PARTIAL ENCROACHMENT. | | | CONSIDER WIDENING THE INTERNAL DRIVE AISLE OR INCREASE | | | CURB TURNING RADIUS. REVISE AUTOTURN ANALYSIS | | | ACCORDINGLY. LATEST RESUBMISSION DID NOT PROVIDE | | | UPDATED DRAWINGS | | | 3) SATISFIED. PROVIDE AUTOTURN SHOWCASING A VEHICLE | | | TURNING FROM THE VALET AISLE TO THE GARAGE | | | 4) NOT SATISFIED. PROVIDE CIVIL ENGINEERING GARAGE | | | PLANS WITH DIMENSIONS | | | 5) NOT SATISFIED. PROVIDE SITE PARKING TABLE | | | 6) A VARIANCE REQUEST MUST BE SUBMITTED PERTAINING | | | NUMBER OF DRIVEWAYS OR THEIR WIDTH. CITY CODE SECTION | | | 94-312-1(A) ALLOWS ONLY ONE ACCESS POINT FOR | | | RESIDENTIAL DEVELOPMENTS WITH LESS THAN 75 UNITS. PART | | | (C)2 ALLOWS A CIRCULAR DRIVEWAY PROVIDED THAT EACH | | | DRIVEWAY OPENING SHALL NOT EXCEED TEN FEET IN WIDTH AT | | | THE PROPERTY LINE OR WHERE THE DRIVEWAY OPENING ADJOINS | | | THE APRON IF THE APRON IS NOT LOCATED WHOLLY WITHIN THE | | | RIGHT-OF-WAY | | | | | | VALERIO ORICCHIO | | | CITY TRANSPORTATION ENGINEER | | | 561-494-1092 | | | [email protected] | | | |
|
|
| Review Stop |
TRAFFIC |
TRAFFIC ENGINEERING |
| Rev No |
1 |
Status |
F |
Date |
06-10-2021 |
|
|
Cont ID |
|
| Sent By |
|
Date |
06-10-2021 |
Time |
|
Rev Time |
|
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2021-06-10 01:49:55 | TRAFFIC COMMENTS | | | 1) PROVIDE COUNTY TPS LETTER | | | | | | SITE COMMENTS | | | 2) AUTOTURN SHOWS PARTIAL ENCROACHMENT. CONSIDER | | | WIDENING THE INTERNAL DRIVE AISLE OR INCREASE CURB | | | TURNING RADIUS. REVISE AUTOTURN ANALYSIS ACCORDINGLY | | | 3) PROVIDE AUTOTURN SHOWCASING A VEHICLE TURNING FROM | | | THE VALET AISLE TO THE GARAGE | | | 4) PROVIDE GARAGE PLANS | | | 5) PROVIDE SITE PARKING TABLE | | | | | | VALERIO ORICCHIO | | | CITY TRANSPORTATION ENGINEER | | | 561-494-1092 | | | [email protected] | | | | | | | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
10-14-2021 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
10-14-2021 |
Time |
09:48 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
10-14-2021 |
Time |
09:47 |
Sent To |
|
|
| Notes |
| 2021-10-14 14:27:01 | PLANS AND PLATS REVIEW COMMITTEE (PPRC) ZONING REVIEW | | | ________________________________________ | | | | | | PROJECT NO.: Z21050010 | | | CASE NO.: PB 1887 | | | ________________________________________ | | | | | | PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING | | | REVIEW COMMENTS: | | | | | | 1. [ SATISFIED ] - APPROVED SCHOOL CAPACITY | | | AVAILABILITY DETERMINATION (SCAD) SHALL BE PROVIDED | | | FROM THE PALM BEACH COUNTY SCHOOL DISTRICT. THE SCAD | | | SHALL INCLUDE APPROVAL FOR THE REZONING, AS WELL AS THE | | | DEVELOPMENT ORDER (ACTUAL PROPOSED DEVELOPMENT). AN | | | UNSIGNED ELECTRONIC FORM WAS INCLUDED IN YOUR | | | SUBMITTAL, BUT IT WAS NOT SIGNED BY THE OWNER/AGENT. IF | | | THIS IS THE VERSION THAT YOU ARE REQUESTING THE CITY TO | | | SIGN BEFORE SUBMITTAL TO THE SCHOOL DISTRICT, IT NEEDS | | | TO FIRST BE SIGNED BY THE OWNER/AGENT. | | | | | | 2. [ STAFF ACKNOWLEDGES THE EFFORTS THAT WERE MADE TO | | | ADDRESS THE CONCERNS LISTED BELOW ? 2.1 THROUGH 2.4 - | | | AND HAS NO COMMENTS AT THIS TIME BUT IS CONTINUING TO | | | REVIEW THE ADDITIONAL ARCHITECTURAL DETAIL THAT WAS | | | PROVIDED ] - THE PLANNING DIVISION HAS SIGNIFICANT | | | CONCERNS WITH REGARD TO: | | | | | | 2.1. THE SIGNIFICANT NUMBER OF WAIVER REQUESTS WITH | | | LITTLE TO NO INDICATION OF HOW THE IMPACTS OF THOSE | | | WAIVERS ARE BEING MITIGATED. | | | | | | 2.2. NO INDICATION ON HOW THE PUBLIC IS TO BENEFIT FROM | | | THE ESTABLISHMENT OF THE PLANNED DEVELOPMENT AND THE | | | ASSOCIATED WAIVERS. PURSUANT TO THE CITY'S ZLDRS, | | | PLANNED DEVELOPMENTS ARE PERMITTED TO ENCOURAGE "THE | | | USE OF INNOVATIVE LAND PLANNING AND DEVELOPMENT | | | TECHNIQUES TO CREATE A MORE DESIRABLE AND ATTRACTIVE | | | DEVELOPMENT". WHAT INNOVATIVE TECHNIQUES ARE BEING | | | UTILIZED? HOW ARE THE BENEFITS MENTIONED IN YOUR | | | JUSTIFICATION ANY DIFFERENT (OR BETTER) THAN WHAT WOULD | | | RESULT FROM A PROJECT THAT CONFORMS TO THE CURRENT | | | ZONING DISTRICT? | | | | | | 2.3. THE CONFIGURATION OF THE FRONT OF THE PROPERTY, | | | INCLUDING CIRCULATION PATTERN AND OPERATION WITH THE | | | GATE/VALET/ETC. AND AMOUNT OF SPACE DEDICATED TO | | | VEHICULAR MOVEMENTS. | | | | | | 2.4. LACK OF "ACTIVE" USE ALONG THE FLAGLER DRIVE | | | STREET FRONTAGE, INCLUDING THE AMOUNT OF AREA DEDICATED | | | TO VEHICULAR USE ON THE GROUND FLOOR, THE PARKING | | | GARAGE ON THE UPPER FLOORS, ETC. | | | | | | 3. [ SATISFIED ] - IN MULTIPLE LOCATIONS | | | (JUSTIFICATION, SITE PLAN, ETC.) THERE IS REFERENCE TO | | | A WAIVING THE LOT WIDTH REQUIREMENT IN TABLE XIII-1; | | | TABLE XIII-1 PERTAINS TO SIGN REGULATIONS. I BELIEVE | | | YOU ARE INTENDING TO REFERENCE TABLE VIII-1. PLEASE | | | ENSURE THAT ALL CODE CITATIONS, ETC. ARE REFERENCED | | | CORRECTLY. | | | | | | 4. [ NOT SATISFIED ] - PAGE 3 OF THE JUSTIFICATION | | | STATEMENT INDICATES THAT THREE (3) WAIVERS ARE BEING | | | REQUESTED, BUT THE PLANS INDICATED SEVEN (7). PLEASE | | | ENSURE THAT ALL DOCUMENTS AND PLANS ARE CONSISTENT AND | | | ACCURATE. | | | | | | 4.1 [ NEW COMMENT ] - THROUGHOUT THE JUSTIFICATION | | | STATEMENT IT INDICATES THAT SIX (6) WAIVERS ARE BEING | | | REQUESTED, BUT THE PLANS CONTINUE TO INDICATE SEVEN (7) | | | WAIVERS. PLEASE ENSURE THAT ALL DOCUMENTS AND PLANS ARE | | | CONSISTENT AND ACCURATE. | | | | | | 5. [ SATISFIED ] - THE JUSTIFICATION STATEMENT CONTAINS | | | MULTIPLE SPELLING AND GRAMMATICAL ERRORS. PLEASE | | | CORRECT. | | | | | | 6. [ SATISFIED ] - PAGE 4 OF THE JUSTIFICATION | | | STATEMENT INDICATES THAT THE MARINA PROJECT IS APPROVED | | | FOR 1,050 UNITS; PLEASE NOTE THAT 1,059 UNITS ARE | | | APPROVED. | | | | | | 7. [ NOT SATISFIED ] - PAGE 4 OF THE JUSTIFICATION | | | STATEMENT INDICATES THAT THE PROPOSED DOCK HAS BEEN | | | APPROVED BY THE FDEP AND THE ARMY CORPS; COPIES OF | | | THOSE APPROVALS ARE REQUESTED. | | | | | | 7.1 [ NEW COMMENT ] - ON PAGE 2 OF 10 OF THE FDEP | | | APPROVAL, IT INDICATES THAT FEDERAL AUTHORIZATION | | | EXPIRED ON 7/25/2016. | | | | | | 7.2 [ NEW COMMENT ] - EXHIBIT A OF THE FDEP APPROVAL | | | INDICATES THAT THE TIME LIMIT FOR COMPLETING THE WORK | | | AUTHORIZED ENDS ON 7/25/2016. | | | | | | 8. [ SATISFIED ] - PAGES 4 AND 9 OF THE JUSTIFICATION | | | STATEMENT MAKE REFERENCE TO SEC. 94-243, TABLE VIII-3 | | | OF THE CITY'S ZLDRS; THIS SECTION OF THE CODE IS THE | | | SCHEDULE OF DISTRICT REGULATIONS FOR COMMERCIAL | | | DISTRICTS. PLEASE ENSURE THAT ALL CODE CITATIONS, ETC. | | | ARE REFERENCED CORRECTLY. | | | | | | 9. [ SATISFIED ] - PAGE 5 OF THE JUSTIFICATION | | | STATEMENT MAKES REFERENCE TO THE REQUIRED BUILDING | | | COVERAGE, OPEN SPACE, PERVIOUS AREA, ETC.; PLEASE NOTE | | | THAT RESIDENTIAL ZONING DISTRICTS DO NOT HAVE THESE | | | REQUIREMENTS. | | | | | | 10. [ SATISFIED ] - THE FRONT SETBACKS (BOTH REQUIRED | | | AND PROPOSED) SHOWN ON PAGE 5 OF THE JUSTIFICATION | | | STATEMENT IS INCORRECT. PLEASE ENSURE THAT ALL DATA IS | | | CORRECT. | | | | | | 11. [ SATISFIED ] - THE CODE REQUIREMENTS SHOWN IN THE | | | TABLE "SCUBA CLUB PROPERTY DEVELOPMENT REQUIREMENTS" ON | | | SHEET SP-1 ARE INCORRECT. | | | | | | 12. [ SATISFIED ] - PAGE 10 OF THE JUSTIFICATION | | | STATEMENT INDICATES THAT SEC. 94-207(C)(4) REQUIRES THE | | | 2:1 RATIO FOR SETBACKS VS. BUILDING HEIGHT; THIS IS | | | INCORRECT. | | | | | | 13. [ SATISIFED ] - PAGE 11 OF THE JUSTIFICATION | | | STATEMENT MAKES REFERENCE TO SEC. 94-243(D)(2)(A) OF | | | THE CITY'S ZLDRS; THIS CODE SECTION DOES NOT EXIST. | | | PLEASE ENSURE THAT ALL CODE CITATIONS, ETC. ARE | | | REFERENCED CORRECTLY. | | | | | | 14. [ SATISFIED ] - AS REQUIRED BY THE DEVELOPMENT | | | APPLICATION, THE LEGAL DESCRIPTION OF THE PROPERTY | | | SHALL BE PROVIDED IN MICROSOFT WORK, OR COMPATIBLE, | | | FORMAT. | | | | | | 15. [ SATISFIED ] - THE OWNER'S CONSENT FORM LISTS THE | | | OWNER AS "SCUBA CLUB MANAGER, LLC", BUT THE WARRANTY | | | DEED PROVIDED INDICATES THAT THE OWNER IS "SCUBA CLUB | | | WPB, LLC". PLEASE ENSURE THAT THE CORRECT OWNER IS | | | LISTED. | | | | | | 16. [ PARTIALLY SATISFIED ] - ALL OF THE REQUIRED | | | PUBLIC UTILITY LETTERS SHALL BE PROVIDED. | | | | | | 16.1 [ NEW COMMENT ] - COMCAST LETTER SHALL BE | | | PROVIDED. | | | | | | 17. [ SATISFIED ] - PURSUANT TO SEC. 94-312(1)(A) OF | | | THE CITY'S ZLDRS, RESIDENTIAL DEVELOPMENTS WITH 75 | | | UNITS OR LESS ARE ONLY PERMITTED ONE (1) ACCESS POINT. | | | ADDITIONALLY, IF MULTIPLE ACCESS POINTS WERE PROVIDED, | | | SEC. 94-312(2)(A) OF THE CITY'S ZLDRS REQUIRES THAT | | | ACCESS POINTS HAVE A MINIMUM SEPARATION DISTANCE OF AT | | | LEAST 125 FEET ON A NON-THOROUGHFARE ROADWAY. | | | | | | 18. [ SATISFIED ] - THE LANDSCAPING SHOWN ON SHEET R7 | | | DOES NOT ACCURATELY REFLECT WHAT IS PROPOSED IN THE | | | SUBMITTED LANDSCAPE PLANS. ENSURE THAT ALL PLANS | | | ACCURATELY MATCH WHAT IS PROPOSED. | | | | | | 19. [ SATISFIED ] - THE LABELING OF THE "GUARD HOUSE" | | | ON SHEET R7 IS PLACED INCORRECTLY. | | | | | | 20. [ SATISFIED ] - THE SETBACK LINE ON THE | | | ARCHITECTURAL PLANS APPEAR TO BE IN THE WRONG LOCATION, | | | SPECIFICALLY THE FRONT SETBACK. | | | | | | 21. [ SATISFIED ] - PURSUANT TO SEC. 94-71(D)(2)(A) OF | | | THE CITY'S ZLDRS, LOT WIDTHS ON THE EAST SIDE OF NORTH | | | FLAGLER DRIVE ARE TO COMPLY WITH SEC. 94-77(A)(1)(L), | | | WHICH REQUIRES A MINIMUM LOT WIDTH OF 75 FEET. MANY OF | | | YOUR PLANS/DOCUMENTS REFERENCE A REQUIRED LOT WIDTH OF | | | 50 FEET; PLEASE ADJUST ACCORDINGLY. | | | | | | 22. [ PARTIALLY SATISFIED ] - IT WAS INDICATED THAT | | | BIKE PARKING IS BEING PROVIDED FOR EIGHT (8) BICYCLES. | | | THE ONLY INFORMATION ON THE PLANS INDICATING ANY | | | BICYCLE FACILITIES HAS BEEN THE BIKE STORAGE ROOM: | | | | | | 22.1. [ SATISFIED ] - PLEASE INDICATE THE LAYOUT OF THE | | | FACILITIES IN THIS ROOM TO ENSURE THAT A SUFFICIENT | | | NUMBER OF FACILITIES ARE BEING PROVIDED. | | | | | | 22.2. [ PARTIALLY SATISFIED ] - ADDITIONAL FACILITIES | | | SHALL BE PROVIDED THAT ARE ACCESSIBLE TO GUESTS, ETC. | | | THAT MAY NOT HAVE ACCESS TO THE BIKE STORAGE ROOM. | | | | | | 22.2.1 [ NEW COMMENT ] ? A DETAIL SHALL BE PROVIDED FOR | | | THE BIKE RACKS LOCATED BEHIND THE VALET STATION AND | | | SUCH RACKS SHALL CONFORM TO THE CITY?S DESIGN | | | REQUIREMENTS, SPACING, ETC. | | | | | | 22.3. [ SATISFIED ] - THE SITE PLAN APPEARS TO SHOW | | | STEPS FROM THE ADJACENT WALKWAY INTO BOTH THE BIKE | | | STORAGE AS WELL AS STAIR 3, ETC. THESE ARE NOT SHOWN ON | | | THE ARCHITECTURAL PLANS. IF STEPS ARE BEING PROVIDED, | | | PLEASE ENSURE THAT THIS IS NOT REQUIRED TO BE ADA | | | ACCESSIBLE. | | | | | | 23. [ SATISFIED ] - THE WAIVER REGARDING THE HEIGHT OF | | | THE BUILDING RELATIVE TO THE SETBACKS SHOULD BE | | | EXPRESSED AS A WAIVER TO THE MAXIMUM BUILDING HEIGHT | | | PERMITTED. THE REFERENCE TO THE SETBACK CAN ALSO BE | | | PROVIDED, BUT THE WAIVER TO THE MAXIMUM HEIGHT SHALL BE | | | EXPRESSLY INDICATED. | | | | | | 24. [ SATISFIED ] - THE SETBACK SHALL BE INDICATED FOR | | | THE MONUMENT SIGN. PER SEC. 94-407(2) OF THE CITY'S | | | ZLDRS, THE SIGN SHALL BE 20 FEET FROM AN ADJACENT | | | PROPERTY, AND 20 FEET FROM THE RIGHT-OF-WAY IF PLACED | | | PERPENDICULAR TO THE STREET. | | | | | | 25. [ SATISFIED ] - THE HEIGHT OF THE FREESTANDING SIGN | | | SHALL BE INDICATED. PER SEC. 94-207(2) OF THE CITY'S | | | ZLDRS, THE SIGN SHALL NOT EXCEED FOUR (4) FEET IN | | | HEIGHT. | | | | | | 26. [ PARTIALLY SATISFIED ] - PLEASE PROVIDE CROSS | | | SECTION (WITH CORRECT ELEVATIONS) SHOWING THE AREA FROM | | | THE NORTH PROPERTY LINE TO THE BUILDING, INCLUDING THE | | | RELATIONSHIP BETWEEN THE PROPOSED RETAINING WALL, THE | | | PROPERTY LINE, THE EXISTING CONCRETE WALL, ETC. | | | | | | 26.1 [ NEW COMMENT ] ? IN THE CROSS SECTIONS, PLEASE | | | PROVIDE THE ELEVATION POINTS FOR THE TOP OF THE | | | RETAINING WALL. | | | | | | 26.2 [ NEW COMMENT ] ? ON THE SOUTH SIDE OF THE | | | BUILDING THE CROSS SECTION IN THE ARCHITECTURAL PLANS | | | SHOW THE SITE SLOPING TOWARD THE ADJACENT PROPERTY, | | | WITH ALL RUNOFF LEAVING THE SITE ONTO THE ADJACENT | | | PROPERTY; THE CIVIL PLANS INDICATE WHAT APPEARS TO BE A | | | SWALE BEFORE THE PROPERTY LINE. PLEASE ENSURE THAT ALL | | | PLANS ARE CONSISTENT. | | | | | | 27. [ SATISFIED ] - ALL SETBACKS NEED TO BE MEASURED | | | FROM THE PROPERTY LINE TO THE CLOSEST POINT OF THE | | | STRUCTURE. IT APPEARS THAT THAT AT LEASE THE REAR | | | SETBACK IS NOT MEASURED TO THE CLOSEST POINT AS THERE | | | ARE STRUCTURAL WALLS, COLUMNS, ETC. THAT ARE CLOSER TO | | | THE PROPERTY LINE AND ARE NOT BEING ACCOUNTED FOR. | | | | | | 28. [ SATISFIED ] - DATA TABLE NEEDS TO INDICATE THE | | | NUMBER OF COMPACT PARKING SPACES AND INDICATE | | | COMPLIANCE WITH SEC. 94-485(N)(1) OF THE CITY'S ZLDRS. | | | | | | 29. [ PARTIALLY SATISFIED ] - TURNAROUND SPACES SHALL | | | BE PROVIDED AT EACH DEAD-END PARKING AREA. | | | | | | 29.1 [ NEW COMMENT ] ? THE TURNAROUND AREA AT THE TOP | | | OF THE 5TH FLOOR NEEDS TO BE STRIPED OUT AS NO PARKING. | | | | | | 30. DETAILS SHALL BE PROVIDED SHOWING THE PROPOSED | | | SCREENING METHODS FOR THE PARKING GARAGE, INCLUDING HOW | | | VEHICLE LIGHTS WILL BE BLOCKED FROM IMPACTING THE | | | ADJACENT PROPERTIES, ETC. | | | | | | 31. [ SATISFIED ] - ADDITIONAL DETAIL NEEDS TO BE | | | PROVIDED ON THE ROOF PLAN/ELEVATIONS TO INDICATE WHY | | | THE HEIGHT OF THE BUILDING IS MEASURED AT 235' 2" AND | | | NOT 244' 2". IS THE AREA ABOVE 235? 2? ENCLOSED, OR IS | | | IT A SCREEN WALL/PARAPET? | | | | | | 32. [ PARTIALLY SATISFIED ] - THE SITE DATA TABLE NEEDS | | | TO INDICATE THE AREA ASSOCIATED WITH THE SUBMERGED | | | LANDS AND INDICATE HOW THE DENSITY COMPLIES WITH SEC. | | | 94-309(F)(3) OF THE CITY'S ZLDRS. NOTE THAT PURSUANT TO | | | SEC. 94-309(F)(2) OF THE CITY'S ZLDRS, "A STATEMENT | | | CONCURRENT WITH LAND DEVELOPMENT APPLICATION OR | | | BUILDING PERMIT APPLICATION, IN A FORM ACCEPTABLE TO | | | THE CITY ATTORNEY, THAT AN APPLICATION TO FILL AND | | | UTILIZE SUBMERGED LANDS WILL NOT BE FILLED FOLLOWING | | | APPROVAL OF THE PLANNED DEVELOPMENT DISTRICT OR | | | ISSUANCE OF BUILDING PERMIT." | | | | | | 32.1 [ NEW COMMENT ] - INFORMATION HAS BEEN PROVIDED | | | REGARDING THE DENSITY CALCULATION AND AN ADDITIONAL | | | WAIVER HAS BEEN ADDED TO INCREASE THE DENSITY | | | ASSOCIATED WITH THE SUBMERGED LANDS. PURSUANT TO SEC. | | | 94-309(F)(4) OF THE CITY'S ZLDRS, PROPOERTIES MUST HAVE | | | AN "AGGREGATE OF UPLAND AND SUBMERGED ACREAGE OF TWO | | | ACRES OR MORE" TO APPLY FOR A PD IN ORDER TO INCREASE | | | THE UTILIZATION OF SUBMERGED LAND. | | | | | | 33. [ PARTIALLY SATISFIED ] - PURSUANT TO SEC. | | | 94-313(A) OF THE CITY'S ZLDRS, THE FOLLOWING | | | INFORMATION SHALL BE PROVIDED FOR THE DOCK IF IT IS TO | | | BE INCLUDED IN THIS APPLICATION: | | | | | | 33.1. [ PARTIALLY SATISFIED ] - A CROSS SECTION SHOWING | | | ALL ELEMENTS OF THE PROPOSED DOCK, BOTTOM OF THE | | | WATERWAY, MEAN HIGH WATER, BULKHEAD, ETC. SHALL BE | | | PROVIDED. NO PORTION OF THE DOCK SHALL EXTEND ABOVE THE | | | HEIGHT OF THE BULKHEAD WITH THE EXCEPTION OF SECURITY | | | FENCES, BOAT LIFTS, AND MOORING DEVICES. | | | | | | 33.1.1 [ NEW COMMENT ] - ARE THE 2015 PLANS PREPARED BY | | | ISIMINGER & STUBBS BEING UTILIZED TO PROVIDE DETAIL | | | REGARDING THE DOCK? THESE PLANS DO NOT COMPLETELY MATCH | | | WHAT IS BEING PROPOSED CURRENTLY. ALL 2015 PLANS NEEDS | | | TO BE UPDATED AND ALL PLANS NEED TO BE CONSISTENT. | | | | | | 33.2. [ PARTIALLY SATISFIED ] - A STUDY SHOWING THAT | | | MARINE GRASSES, ETC. ARE NOT BEING IMPACTED BY THE | | | PROPOSED DOCK CONSTRUCTION. | | | | | | 33.2.1 [ NEW COMMENT ] - ARE THE 2015 PLAN PREPARED BY | | | ISIMINGER & STUBBS BEING UTILIZED TO PROVIDE DETAIL | | | REGARDING THE DOCK CONSTRUCTION? ALL 2015 PLANS NEEDS | | | TO BE UPDATED AND ALL PLANS NEED TO BE CONSISTENT. | | | | | | 33.3. [ NOT SATISFIED ] - THE DISTANCE FROM THE END OF | | | THE PROPOSED DOCK TO THE NAVIGABLE CHANNEL. | | | | | | 33.4. [ SATISFIED ] - A NOTATION SHALL BE MADE | | | INDICATING THAT ALL SLIPS WITH BE PROVIDED WITH | | | APPROPRIATE WATER AND ELECTRICAL SERVICE. | | | | | | 33.5. [ SATISFIED ] - AT LEAST ONE LADDER SHALL BE | | | PROVIDED FOR EACH DOCK, EXTENDING FROM THE DOCK SURFACE | | | TO 2 FEET BELOW MEAN LOW WATER. | | | | | | 33.6. [ SATISFIED ] - WATER-RESISTANT REFLECTIVE NUMBER | | | SHALL E PROVIDED ON THE END OF THE DOCK, VISIBLE FROM | | | THE WATERWAY, CORRESPONDING TO THE STREET ADDRESS. | | | | | | 34. [ PARTIALLY SATISFIED ] - PLEASE CLARIFY WHAT | | | APPEAR TO BE PILINGS LOCATED OUTSIDE THE MIDDLE 1/3 OF | | | THE LOT. ALL PILINGS, MOORING RELATED FACILITIES, ETC. | | | SHALL BE CONSTRUCTED WITHIN THE MIDDLE 1/3 OF THE LOT, | | | AS REQUIRED BY SEC. 94-313(A)(3)(H) OF THE CITY'S | | | ZLDRS. | | | | | | 34.1 [ NEW COMMENT ] - ARE THE 2015 PLANS PREPARED BY | | | ISIMINGER & STUBBS BEING UTILIZED TO PROVIDE DETAIL | | | REGARDING THE DOCK CONSTRUCTION? THESE PLANS DO NOT | | | COMPLETELY MATCH WHAT IS BEING PROPOSED CURRENTLY. THE | | | DOCK PLAN ON SHEET SP-1 DOES NOT SHOW ANY MOORING | | | PILINGS. LOCATIONS OF ALL MOORING FACILITIES, BOAT | | | LIFTS, ETC. NEED TO BE SHOWN TO ENSURE PLACEMENT WITHIN | | | THE REQUIRED SETBACKS. ALL 2015 PLANS NEEDS TO BE | | | UPDATED AND ALL PLANS NEED TO BE CONSISTENT. | | | | | | 35. [ SATISFIED ] - THE DOCK PLATFORM ADJACENT TO THE | | | SEAWALL APPEARS TO BE ENCROACHING OUTSIDE THE MIDDLE | | | 1/3 OF THE LOT. ADDITIONALLY, THE PLATFORM SHOWN ON THE | | | SITE PLAN DOES NOT MATCH THAT WHICH IS SHOWN ON THE | | | CIVIL PLANS. ENSURE THAT ALL PLANS ARE CONSISTENT AND | | | ACCURATE. | | | | | | 36. [ SATISFIED ] - PURSUANT TO SEC. | | | 94-313(A)(3)(G)(II) OF THE CITY'S ZLDRS, DOCKS | | | CONTAINING FOUR OR MORE MOORING SLIPS SHALL PROVIDE | | | SANITARY SEWER PUMP OUT FACILITIES ON THE FOLLOWING | | | BASIS: ONE SANITARY SEWER PUMP OUT RECEPTACLE FOR EVERY | | | EIGHT MOORING SLIPS OR FRACTION THEREOF, OR APPROPRIATE | | | CONNECTIONS TO EACH MOORING SLIP. | | | | | | 37. [ NEW COMMENT [ - PLEASE PROVIDE DETAILS REGARDING | | | THE GREEN WALL ON THE SOUTH SIDE OF THE PROPERTY | | | (HEIGHT OF THE WALL, ETC.) AS WELL AS THE HEIGHT OF THE | | | KNEE WALL THAT IS PROPOSED ALONG THE FRONT OF THE | | | PROPERTY. | | | | | | ________________________________________ | | | | | | PLEASE NOTE THE FOLLOWING WHEN RESUBMITTING: | | | | | | A) WRITTEN RESPONSES TO COMMENTS MADE BY ALL | | | DEPARTMENTS SHALL BE PROVIDED UPON RESUBMISSION. | | | | | | B) ELECTRONIC COPIES OF REVISED PLANS AND/OR DOCUMENTS | | | SHALL BE PROVIDED. | | | | | | C) PLEASE NOTE THAT RE-SUBMITTALS MAY BE SUBJECT TO | | | ADDITIONAL COMMENTS. | | | | | | D) IF NO RESPONSE IS RECEIVED WITHIN 60 DAYS OF THE | | | ISSUANCE OF THESE COMMENTS, THE APPLICATION WILL BE | | | CONSIDERED WITHDRAWN AND ANY FURTHER ACTION WILL | | | REQUIRE SUBMISSION OF A NEW DEVELOPMENT APPLICATION. | | | | | | E) PLEASE NOTE THAT YOU WILL BE PERMITTED ONE (1) | | | RESUBMITTAL AT NO ADDITIONAL COST. IF PREVIOUSLY-ISSUED | | | COMMENTS CONTINUE TO NOT BE SUFFICIENTLY ADDRESSED, THE | | | APPLICANT WILL BE ACCESSED A RESUBMITTAL FEE. SUCH FEE | | | WILL BE 20% OF THE ORIGINAL APPLICATION FEE. | | | | | | F) IN ORDER TO BE CONSIDERED FOR THE NOVEMBER 16, 2021, | | | PLANNING BOARD AGENDA, ALL COMMENTS SHALL BE | | | SATISFACTORILY ADDRESSED. PLEASE SUBMIT ALL REVISED | | | DOCUMENTS/PLANS NO LATER THAN MONDAY, OCTOBER 25, 2021. | | | | | | G) TO BE PLACED ON THE NOVEMBER 16, 2021, PLANNING | | | BOARD AGENDA, SIGNS SHALL BE POSTED ON THE PROPERTY NO | | | LATER THAN NOVEMBER 1, 2021. SIGNAGE SHALL CONFORM, AND | | | BE INSTALLED ACCORDING TO THE REQUIREMENTS OF THE | | | CITY?S ZONING AND LAND DEVELOPMENT REGULATIONS; SUCH | | | REQUIREMENTS ARE ALSO PROVIDED IN THE DEVELOPMENT | | | APPLICATION. A SIGNED AND NOTARIZED AFFIDAVIT SHALL BE | | | PROVIDED BY THE DEADLINE REFERENCED ABOVE. | | | | | | H) IF AFTER THE CASE HAS BEEN ADVERTISED THE APPLICANT | | | DESIRES TO REQUEST A CONTINUANCE, A FEE OF $50 PLUS THE | | | COST OF ADVERTISING WILL BE CHARGED. | | | ________________________________________ | | | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | | | JOHN P. ROACH, AICP, PRINCIPAL PLANNER | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION | | | 401 CLEMATIS STREET - P.O. BOX 3147 | | | WEST PALM BEACH, FLORIDA 33402 | | | | | | P: 561.822.1448 | | | TTY: 800.955.8771 | | | E: [email protected] | | | | | | W: WPB.ORG | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
07-20-2021 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
07-20-2021 |
Time |
09:15 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
07-20-2021 |
Time |
09:15 |
Sent To |
|
|
| Notes |
| 2021-07-20 09:16:05 | PLANS AND PLATS REVIEW COMMITTEE (PPRC) ZONING REVIEW | | | ________________________________________ | | | | | | PROJECT NO.: Z21050010 | | | CASE NO.: PB 1887 | | | ________________________________________ | | | | | | PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING | | | REVIEW COMMENTS: | | | | | | 1. APPROVED SCHOOL CAPACITY AVAILABILITY DETERMINATION | | | (SCAD) SHALL BE PROVIDED FROM THE PALM BEACH COUNTY | | | SCHOOL DISTRICT. THE SCAD SHALL INCLUDE APPROVAL FOR | | | THE REZONING, AS WELL AS THE DEVELOPMENT ORDER (ACTUAL | | | PROPOSED DEVELOPMENT). AN UNSIGNED ELECTRONIC FORM WAS | | | INCLUDED IN YOUR SUBMITTAL, BUT IT WAS NOT SIGNED BY | | | THE OWNER/AGENT. IF THIS IS THE VERSION THAT YOU ARE | | | REQUESTING THE CITY TO SIGN BEFORE SUBMITTAL TO THE | | | SCHOOL DISTRICT, IT NEEDS TO FIRST BE SIGNED BY THE | | | OWNER/AGENT. | | | | | | 2. THE PLANNING DIVISION HAS SIGNIFICANT CONCERNS WITH | | | REGARD TO: | | | | | | 2.1. THE SIGNIFICANT NUMBER OF WAIVER REQUESTS WITH | | | LITTLE TO NO INDICATION OF HOW THE IMPACTS OF THOSE | | | WAIVERS ARE BEING MITIGATED. | | | | | | 2.2. NO INDICATION ON HOW THE PUBLIC IS TO BENEFIT FROM | | | THE ESTABLISHMENT OF THE PLANNED DEVELOPMENT AND THE | | | ASSOCIATED WAIVERS. PURSUANT TO THE CITY'S ZLDRS, | | | PLANNED DEVELOPMENTS ARE PERMITTED TO ENCOURAGE "THE | | | USE OF INNOVATIVE LAND PLANNING AND DEVELOPMENT | | | TECHNIQUES TO CREATE A MORE DESIRABLE AND ATTRACTIVE | | | DEVELOPMENT". WHAT INNOVATIVE TECHNIQUES ARE BEING | | | UTILIZED? HOW ARE THE BENEFITS MENTIONED IN YOUR | | | JUSTIFICATION ANY DIFFERENT (OR BETTER) THAN WHAT WOULD | | | RESULT FROM A PROJECT THAT CONFORMS TO THE CURRENT | | | ZONING DISTRICT? | | | | | | 2.3. THE CONFIGURATION OF THE FRONT OF THE PROPERTY, | | | INCLUDING CIRCULATION PATTERN AND OPERATION WITH THE | | | GATE/VALET/ETC. AND AMOUNT OF SPACE DEDICATED TO | | | VEHICULAR MOVEMENTS. | | | | | | 2.4. LACK OF "ACTIVE" USE ALONG THE FLAGLER DRIVE | | | STREET FRONTAGE, INCLUDING THE AMOUNT OF AREA DEDICATED | | | TO VEHICULAR USE ON THE GROUND FLOOR, THE PARKING | | | GARAGE ON THE UPPER FLOORS, ETC. | | | | | | 3. IN MULTIPLE LOCATIONS (JUSTIFICATION, SITE PLAN, | | | ETC.) THERE IS REFERENCE TO A WAIVING THE LOT WIDTH | | | REQUIREMENT IN TABLE XIII-1; TABLE XIII-1 PERTAINS TO | | | SIGN REGULATIONS. I BELIEVE YOU ARE INTENDING TO | | | REFERENCE TABLE VIII-1. PLEASE ENSURE THAT ALL CODE | | | CITATIONS, ETC. ARE REFERENCED CORRECTLY. | | | | | | 4. PAGE 3 OF THE JUSTIFICATION STATEMENT INDICATES THAT | | | THREE (3) WAIVERS ARE BEING REQUESTED, BUT THE PLANS | | | INDICATED SEVEN (7). PLEASE ENSURE THAT ALL DOCUMENTS | | | AND PLANS ARE CONSISTENT AND ACCURATE. | | | | | | 5. THE JUSTIFICATION STATEMENT CONTAINS MULTIPLE | | | SPELLING AND GRAMMATICAL ERRORS. PLEASE CORRECT. | | | | | | 6. PAGE 4 OF THE JUSTIFICATION STATEMENT INDICATES THAT | | | THE MARINA PROJECT IS APPROVED FOR 1,050 UNITS; PLEASE | | | NOTE THAT 1,059 UNITS ARE APPROVED. | | | | | | 7. PAGE 4 OF THE JUSTIFICATION STATEMENT INDICATES THAT | | | THE PROPOSED DOCK HAS BEEN APPROVED BY THE FDEP AND THE | | | ARMY CORPS; COPIES OF THOSE APPROVALS ARE REQUESTED. | | | | | | 8. PAGES 4 AND 9 OF THE JUSTIFICATION STATEMENT MAKE | | | REFERENCE TO SEC. 94-243, TABLE VIII-3 OF THE CITY'S | | | ZLDRS; THIS SECTION OF THE CODE IS THE SCHEDULE OF | | | DISTRICT REGULATIONS FOR COMMERCIAL DISTRICTS. PLEASE | | | ENSURE THAT ALL CODE CITATIONS, ETC. ARE REFERENCED | | | CORRECTLY. | | | | | | 9. PAGE 5 OF THE JUSTIFICATION STATEMENT MAKES | | | REFERENCE TO THE REQUIRED BUILDING COVERAGE, OPEN | | | SPACE, PERVIOUS AREA, ETC.; PLEASE NOTE THAT | | | RESIDENTIAL ZONING DISTRICTS DO NOT HAVE THESE | | | REQUIREMENTS. | | | | | | 10. THE FRONT SETBACKS (BOTH REQUIRED AND PROPOSED) | | | SHOWN ON PAGE 5 OF THE JUSTIFICATION STATEMENT IS | | | INCORRECT. PLEASE ENSURE THAT ALL DATA IS CORRECT. | | | | | | 11. THE CODE REQUIREMENTS SHOWN IN THE TABLE "SCUBA | | | CLUB PROPERTY DEVELOPMENT REQUIREMENTS" ON SHEET SP-1 | | | ARE INCORRECT. | | | | | | 12. PAGE 10 OF THE JUSTIFICATION STATEMENT INDICATES | | | THAT SEC. 94-207(C)(4) REQUIRES THE 2:1 RATIO FOR | | | SETBACKS VS. BUILDING HEIGHT; THIS IS INCORRECT. | | | | | | 13. PAGE 11 OF THE JUSTIFICATION STATEMENT MAKES | | | REFERENCE TO SEC. 94-243(D)(2)(A) OF THE CITY'S ZLDRS; | | | THIS CODE SECTION DOES NOT EXIST. PLEASE ENSURE THAT | | | ALL CODE CITATIONS, ETC. ARE REFERENCED CORRECTLY. | | | | | | 14. AS REQUIRED BY THE DEVELOPMENT APPLICATION, THE | | | LEGAL DESCRIPTION OF THE PROPERTY SHALL BE PROVIDED IN | | | MICROSOFT WORK, OR COMPATIBLE, FORMAT. | | | | | | 15. THE OWNER'S CONSENT FORM LISTS THE OWNER AS "SCUBA | | | CLUB MANAGER, LLC", BUT THE WARRANTY DEED PROVIDED | | | INDICATES THAT THE OWNER IS "SCUBA CLUB WPB, LLC". | | | PLEASE ENSURE THAT THE CORRECT OWNER IS LISTED. | | | | | | 16. ALL OF THE REQUIRED PUBLIC UTILITY LETTERS SHALL BE | | | PROVIDED. | | | | | | 17. PURSUANT TO SEC. 94-312(1)(A) OF THE CITY'S ZLDRS, | | | RESIDENTIAL DEVELOPMENTS WITH 75 UNITS OR LESS ARE ONLY | | | PERMITTED ONE (1) ACCESS POINT. ADDITIONALLY, IF | | | MULTIPLE ACCESS POINTS WERE PROVIDED, SEC. 94-312(2)(A) | | | OF THE CITY'S ZLDRS REQUIRES THAT ACCESS POINTS HAVE A | | | MINIMUM SEPARATION DISTANCE OF AT LEAST 125 FEET ON A | | | NON-THOROUGHFARE ROADWAY. | | | | | | 18. THE LANDSCAPING SHOWN ON SHEET R7 DOES NOT | | | ACCURATELY REFLECT WHAT IS PROPOSED IN THE SUBMITTED | | | LANDSCAPE PLANS. ENSURE THAT ALL PLANS ACCURATELY MATCH | | | WHAT IS PROPOSED. | | | | | | 19. THE LABELING OF THE "GUARD HOUSE" ON SHEET R7 IS | | | PLACED INCORRECTLY. | | | | | | 20. THE SETBACK LINE ON THE ARCHITECTURAL PLANS APPEAR | | | TO BE IN THE WRONG LOCATION, SPECIFICALLY THE FRONT | | | SETBACK. | | | | | | 21. PURSUANT TO SEC. 94-71(D)(2)(A) OF THE CITY'S | | | ZLDRS, LOT WIDTHS ON THE EAST SIDE OF NORTH FLAGLER | | | DRIVE ARE TO COMPLY WITH SEC. 94-77(A)(1)(L), WHICH | | | REQUIRES A MINIMUM LOT WIDTH OF 75 FEET. MANY OF YOUR | | | PLANS/DOCUMENTS REFERENCE A REQUIRED LOT WIDTH OF 50 | | | FEET; PLEASE ADJUST ACCORDINGLY. | | | | | | 22. IT WAS INDICATED THAT BIKE PARKING IS BEING | | | PROVIDED FOR EIGHT (8) BICYCLES. THE ONLY INFORMATION | | | ON THE PLANS INDICATING ANY BICYCLE FACILITIES HAS BEEN | | | THE BIKE STORAGE ROOM: | | | | | | 22.1. PLEASE INDICATE THE LAYOUT OF THE FACILITIES IN | | | THIS ROOM TO ENSURE THAT A SUFFICIENT NUMBER OF | | | FACILITIES ARE BEING PROVIDED. | | | | | | 22.2. ADDITIONAL FACILITIES SHALL BE PROVIDED THAT ARE | | | ACCESSIBLE TO GUESTS, ETC. THAT MAY NOT HAVE ACCESS TO | | | THE BIKE STORAGE ROOM. | | | | | | 22.3. THE SITE PLAN APPEARS TO SHOW STEPS FROM THE | | | ADJACENT WALKWAY INTO BOTH THE BIKE STORAGE AS WELL AS | | | STAIR 3, ETC. THESE ARE NOT SHOWN ON THE ARCHITECTURAL | | | PLANS. IF STEPS ARE BEING PROVIDED, PLEASE ENSURE THAT | | | THIS IS NOT REQUIRED TO BE ADA ACCESSIBLE. | | | | | | 23. THE WAIVER REGARDING THE HEIGHT OF THE BUILDING | | | RELATIVE TO THE SETBACKS SHOULD BE EXPRESSED AS A | | | WAIVER TO THE MAXIMUM BUILDING HEIGHT PERMITTED. THE | | | REFERENCE TO THE SETBACK CAN ALSO BE PROVIDED, BUT THE | | | WAIVER TO THE MAXIMUM HEIGHT SHALL BE EXPRESSLY | | | INDICATED. | | | | | | 24. THE SETBACK SHALL BE INDICATED FOR THE MONUMENT | | | SIGN. PER SEC. 94-407(2) OF THE CITY'S ZLDRS, THE SIGN | | | SHALL BE 20 FEET FROM AN ADJACENT PROPERTY, AND 20 FEET | | | FROM THE RIGHT-OF-WAY IF PLACED PERPENDICULAR TO THE | | | STREET. | | | | | | 25. THE HEIGHT OF THE FREESTANDING SIGN SHALL BE | | | INDICATED. PER SEC. 94-207(2) OF THE CITY'S ZLDRS, THE | | | SIGN SHALL NOT EXCEED FOUR (4) FEET IN HEIGHT. | | | | | | 26. PLEASE PROVIDE CROSS SECTION (WITH CORRECT | | | ELEVATIONS) SHOWING THE AREA FROM THE NORTH PROPERTY | | | LINE TO THE BUILDING, INCLUDING THE RELATIONSHIP | | | BETWEEN THE PROPOSED RETAINING WALL, THE PROPERTY LINE, | | | THE EXISTING CONCRETE WALL, ETC. | | | | | | 27. ALL SETBACKS NEED TO BE MEASURED FROM THE PROPERTY | | | LINE TO THE CLOSEST POINT OF THE STRUCTURE. IT APPEARS | | | THAT THAT AT LEASE THE REAR SETBACK IS NOT MEASURED TO | | | THE CLOSEST POINT AS THERE ARE STRUCTURAL WALLS, | | | COLUMNS, ETC. THAT ARE CLOSER TO THE PROPERTY LINE AND | | | ARE NOT BEING ACCOUNTED FOR. | | | | | | 28. DATA TABLE NEEDS TO INDICATE THE NUMBER OF COMPACT | | | PARKING SPACES AND INDICATE COMPLIANCE WITH SEC. | | | 94-485(N)(1) OF THE CITY'S ZLDRS. | | | | | | 29. TURNAROUND SPACES SHALL BE PROVIDED AT EACH | | | DEAD-END PARKING AREA. | | | | | | 30. DETAILS SHALL BE PROVIDED SHOWING THE PROPOSED | | | SCREENING METHODS FOR THE PARKING GARAGE, INCLUDING HOW | | | VEHICLE LIGHTS WILL BE BLOCKED FROM IMPACTING THE | | | ADJACENT PROPERTIES, ETC. | | | | | | 31. ADDITIONAL DETAIL NEEDS TO BE PROVIDED ON THE ROOF | | | PLAN/ELEVATIONS TO INDICATE WHY THE HEIGHT OF THE | | | BUILDING IS MEASURED AT 235' 2" AND NOT 244' 2". IS THE | | | AREA ABOVE 235? 2? ENCLOSED, OR IS IT A SCREEN | | | WALL/PARAPET? | | | | | | 32. THE SITE DATA TABLE NEEDS TO INDICATE THE AREA | | | ASSOCIATED WITH THE SUBMERGED LANDS AND INDICATE HOW | | | THE DENSITY COMPLIES WITH SEC. 94-309(F)(3) OF THE | | | CITY'S ZLDRS. NOTE THAT PURSUANT TO SEC. 94-309(F)(2) | | | OF THE CITY'S ZLDRS, "A STATEMENT CONCURRENT WITH LAND | | | DEVELOPMENT APPLICATION OR BUILDING PERMIT APPLICATION, | | | IN A FORM ACCEPTABLE TO THE CITY ATTORNEY, THAT AN | | | APPLICATION TO FILL AND UTILIZE SUBMERGED LANDS WILL | | | NOT BE FILLED FOLLOWING APPROVAL OF THE PLANNED | | | DEVELOPMENT DISTRICT OR ISSUANCE OF BUILDING PERMIT." | | | | | | 33. PURSUANT TO SEC. 94-313(A) OF THE CITY'S ZLDRS, THE | | | FOLLOWING INFORMATION SHALL BE PROVIDED FOR THE DOCK IF | | | IT IS TO BE INCLUDED IN THIS APPLICATION: | | | | | | 33.1. A CROSS SECTION SHOWING ALL ELEMENTS OF THE | | | PROPOSED DOCK, BOTTOM OF THE WATERWAY, MEAN HIGH WATER, | | | BULKHEAD, ETC. SHALL BE PROVIDED. NO PORTION OF THE | | | DOCK SHALL EXTEND ABOVE THE HEIGHT OF THE BULKHEAD WITH | | | THE EXCEPTION OF SECURITY FENCES, BOAT LIFTS, AND | | | MOORING DEVICES. | | | | | | 33.2. A STUDY SHOWING THAT MARINE GRASSES, ETC. ARE NOT | | | BEING IMPACTED BY THE PROPOSED DOCK CONSTRUCTION. | | | | | | 33.3. THE DISTANCE FROM THE END OF THE PROPOSED DOCK TO | | | THE NAVIGABLE CHANNEL. | | | | | | 33.4. A NOTATION SHALL BE MADE INDICATING THAT ALL | | | SLIPS WITH BE PROVIDED WITH APPROPRIATE WATER AND | | | ELECTRICAL SERVICE. | | | | | | 33.5. AT LEAST ONE LADDER SHALL BE PROVIDED FOR EACH | | | DOCK, EXTENDING FROM THE DOCK SURFACE TO 2 FEET BELOW | | | MEAN LOW WATER. | | | | | | 33.6. WATER-RESISTANT REFLECTIVE NUMBER SHALL E | | | PROVIDED ON THE END OF THE DOCK, VISIBLE FROM THE | | | WATERWAY, CORRESPONDING TO THE STREET ADDRESS. | | | | | | 34. PLEASE CLARIFY WHAT APPEAR TO BE PILINGS LOCATED | | | OUTSIDE THE MIDDLE 1/3 OF THE LOT. ALL PILINGS, MOORING | | | RELATED FACILITIES, ETC. SHALL BE CONSTRUCTED WITHIN | | | THE MIDDLE 1/3 OF THE LOT, AS REQUIRED BY SEC. | | | 94-313(A)(3)(H) OF THE CITY'S ZLDRS. | | | | | | 35. THE DOCK PLATFORM ADJACENT TO THE SEAWALL APPEARS | | | TO BE ENCROACHING OUTSIDE THE MIDDLE 1/3 OF THE LOT. | | | ADDITIONALLY, THE PLATFORM SHOWN ON THE SITE PLAN DOES | | | NOT MATCH THAT WHICH IS SHOWN ON THE CIVIL PLANS. | | | ENSURE THAT ALL PLANS ARE CONSISTENT AND ACCURATE. | | | | | | 36. PURSUANT TO SEC. 94-313(A)(3)(G)(II) OF THE CITY'S | | | ZLDRS, DOCKS CONTAINING FOUR OR MORE MOORING SLIPS | | | SHALL PROVIDE SANITARY SEWER PUMP OUT FACILITIES ON THE | | | FOLLOWING BASIS: ONE SANITARY SEWER PUMP OUT RECEPTACLE | | | FOR EVERY EIGHT MOORING SLIPS OR FRACTION THEREOF, OR | | | APPROPRIATE CONNECTIONS TO EACH MOORING SLIP. | | | | | | ________________________________________ | | | | | | PLEASE NOTE THE FOLLOWING WHEN RESUBMITTING: | | | | | | A) WRITTEN RESPONSES TO COMMENTS MADE BY ALL | | | DEPARTMENTS SHALL BE PROVIDED UPON RESUBMISSION. | | | | | | B) ELECTRONIC COPIES OF REVISED PLANS AND/OR DOCUMENTS | | | SHALL BE PROVIDED. | | | | | | C) PLEASE NOTE THAT RE-SUBMITTALS MAY BE SUBJECT TO | | | ADDITIONAL COMMENTS. | | | | | | D) IF NO RESPONSE IS RECEIVED WITHIN 60 DAYS OF THE | | | ISSUANCE OF THESE COMMENTS, THE APPLICATION WILL BE | | | CONSIDERED WITHDRAWN AND ANY FURTHER ACTION WILL | | | REQUIRE SUBMISSION OF A NEW DEVELOPMENT APPLICATION. | | | | | | E) PLEASE NOTE THAT YOU WILL BE PERMITTED ONE (1) | | | RESUBMITTAL AT NO ADDITIONAL COST. IF PREVIOUSLY-ISSUED | | | COMMENTS CONTINUE TO NOT BE SUFFICIENTLY ADDRESSED, THE | | | APPLICANT WILL BE ACCESSED A RESUBMITTAL FEE. SUCH FEE | | | WILL BE 20% OF THE ORIGINAL APPLICATION FEE. | | | | | | F) IN ORDER TO BE CONSIDERED FOR THE SEPTEMBER 21, | | | 2021, PLANNING BOARD AGENDA, ALL COMMENTS SHALL BE | | | SATISFACTORILY ADDRESSED. PLEASE SUBMIT ALL REVISED | | | DOCUMENTS/PLANS NO LATER THAN MONDAY, AUGUST 2, 2021. | | | | | | G) TO BE PLACED ON THE SEPTEMBER 21, 2021, PLANNING | | | BOARD AGENDA, SIGNS SHALL BE POSTED ON THE PROPERTY NO | | | LATER THAN SEPTEMBER 6, 2021. SIGNAGE SHALL CONFORM, | | | AND BE INSTALLED ACCORDING TO THE REQUIREMENTS OF THE | | | CITY?S ZONING AND LAND DEVELOPMENT REGULATIONS; SUCH | | | REQUIREMENTS ARE ALSO PROVIDED IN THE DEVELOPMENT | | | APPLICATION. A SIGNED AND NOTARIZED AFFIDAVIT SHALL BE | | | PROVIDED BY THE DEADLINE REFERENCED ABOVE. | | | | | | H) IF AFTER THE CASE HAS BEEN ADVERTISED THE APPLICANT | | | DESIRES TO REQUEST A CONTINUANCE, A FEE OF $50 PLUS THE | | | COST OF ADVERTISING WILL BE CHARGED. | | | ________________________________________ | | | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | | | JOHN P. ROACH, AICP, PRINCIPAL PLANNER | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION | | | 401 CLEMATIS STREET - P.O. BOX 3147 | | | WEST PALM BEACH, FLORIDA 33402 | | | | | | P: 561.822.1448 | | | TTY: 800.955.8771 | | | E: [email protected] | | | | | | W: WPB.ORG | | | |
|
|
| |
Print |
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |