Plan Review Details - Project Z21010014
| Plan Review Stops For Project Z21010014 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
02-10-2021 |
|
|
Cont ID |
|
| Sent By |
rbrown |
Date |
02-10-2021 |
Time |
20:06 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
02-10-2021 |
Time |
20:06 |
Sent To |
|
|
| Notes |
| 2021-02-10 20:08:26 | DEVELOPMENT SERVICES DEPARTMENT, BUILDING DIVISION, | | | COMMENTS: | | | | | | 1. THIS REVIEW IS A CURSORY REVIEW AS IT RELATES TO THE | | | SITE. IT IS NOT A REVIEW FOR FULL COMPLIANCE WITH | | | FLORIDA BUILDING CODE. THE FOLLOWING COMMENTS ARE TO BE | | | ADDRESSED FOR THE BUILDING PERMIT APPLICATION. | | | | | | 2. THE ADDITION TO THE EXISTING BUILDING IS COVERED BY | | | CHAPTER 11 OF THE FLORIDA EXISTING BUILDING CODE. THE | | | HEIGHT AND/OR AREA INCREASE DUE TO THE PROPOSED | | | ADDITION SHALL NOT INCREASE THE TOTAL BUILDING HEIGHT | | | AND/OR AREA BEYOND THAT ALLOWED UNDER THE APPLICABLE | | | PROVISIONS OF CHAPTER 5 OF THE FLORIDA BUILDING CODE | | | FOR THE TYPE OF CONSTRUCTION USED. | | | | | | 3. SEPARATE PERMITS REQUIRED. ALL APPLICABLE PERMITS | | | AND SUB-PERMITS MUST BE OBTAINED BEFORE COMMENCING THE | | | WORK. SEPARATE PERMITS, PLANS AND FEES, ARE REQUIRED | | | FOR SIGNS, GAS SYSTEMS, GENERATORS, FIRE ALARM SYSTEMS, | | | FIRE SPRINKLER AND OTHER FIRE SUPPRESSION SYSTEMS, | | | GREASE INTERCEPTORS, SITE LIGHTING, SITE LANDSCAPE, | | | SITE IRRIGATION, ETC. | | | | | | 4. PROTECTION OF NEIGHBORING PROPERTY. PROPERTY OWNER | | | AND CONTRACTOR SHALL PROTECT ALL NEIGHBORING PROPERTY, | | | INCLUDING VEHICLES, FROM DAMAGE OR DIRT CAUSED BY THE | | | CONSTRUCTION, AND SHALL NOTIFY THE OCCUPANTS OF | | | NEIGHBORING PROPERTIES ABOUT ALL STAGES OF CONSTRUCTION | | | THAT MAY AFFECT THE USE OF THEIR PROPERTY. | | | | | | ROBERT BROWN | | | BUILDING OFFICIAL | | | TEL: 561 805 6652 | | | EMAIL: [email protected] | | | |
|
|
| Review Stop |
ENG - PPRC |
ENGINEERING - PPRC |
| Rev No |
5 |
Status |
P |
Date |
03-29-2022 |
|
|
Cont ID |
|
| Sent By |
rrossano |
Date |
03-29-2022 |
Time |
|
Rev Time |
0.00 |
| Received By |
rrossano |
Date |
03-29-2022 |
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
ENG - PPRC |
ENGINEERING - PPRC |
| Rev No |
4 |
Status |
F |
Date |
07-14-2021 |
|
|
Cont ID |
|
| Sent By |
rrossano |
Date |
07-14-2021 |
Time |
|
Rev Time |
0.00 |
| Received By |
rrossano |
Date |
07-14-2021 |
Time |
|
Sent To |
|
|
| Notes |
| 2021-07-14 14:24:56 | COMMENT FROM RICK ROSSANO, PROJECT COORDINATOR, | | | ENGINEERING SERVICES DEPARTMENT DIRECT: (561) 494-1098 | | | [email protected] | | | | | | 1. PROVIDE CCTV VIDEO OF EXISTING SANITARY SEWER IN | | | ALLEY. (CCTV IS CONDITION OF SITE PLAN APPROVAL). | | | | | | THE FOLLOWING COMMENTS ARE FROM MARK HURLEY, FIELD | | | CUSTOMER SERVICE SUPERVISOR, WPB PUBLIC UTILITIES, | | | PLEASE CONTACT 561-494-2262 OR [email protected]: | | | | | | PLEASE PROVIDE WRITTEN RESPONSES TO THE FOLLOWING | | | REVIEW COMMENTS: | | | -PROPOSED FIRELINE WATER SERVICE LOCATION IS ONLY | | | ACCEPTABLE IF ALLEY R/W VACATION REQUEST IS APPROVED. | | | -ADD WATER DEMAND CALCULATIONS TO ENGINEERING PLAN | | | ALONG WITH THE EXISTING WATER METER AND WATER SERVICE | | | SIZE. | | | -PROPOSED UTILITY EASEMENT IS NOT LABELED ON UTILITY | | | PLAN. | | | -FOR FORMAL ENGINEERING SUBMITTAL, PLEASE ADD PROPERTY | | | ADDRESS TO ENGINEERING PLAN AND ADD NOTE THAT BACKFLOW | | | ASSEMBLIES NEED 18INCHES CLEARANCE AROUND THEM. ALSO | | | LABEL FIRELINE GATE VALVE - (FIRELINE POINT OF | | | SERVICE), AND SHOW FRANCHISE UTILITIES NEAR FIRELINE | | | TAP. | | | -WILL IRRIGATION WATER BE USED FROM EXISTING WATER | | | SERVICE OR WILL ANOTHER WATER SERVICE BE NEEDED? | | | -BACKFLOW ASSEMBLIES MUST BE LOCATED ON PRIVATE | | | PROPERTY AND MAY NOT EXTEND INTO UTILITY EASEMENTS OR | | | RIGHT OF WAYS. | | | -FOR FORMAL ENGINEERING SUBMITTAL: LABEL THE DOMESTIC | | | WATER SERVICE LINE PIPE WITH MATERIAL TYPE AND SIZE, | | | LABEL THE PIPING BETWEEN THE WATER METER AND BACKFLOW | | | ASSEMBLY AND MAKE SURE IT COMPLIES WITH SMALL BACKFLOW | | | ASSEMBLY STANDARD DETAIL, ADD WATER METER SIZE TO | | | LABEL. | | | -PLEASE LABEL 8 INCH SAN PIPE ON SITE AS PRIVATE OR | | | CITY. IF WILL BE CITY-OWNED, THEN SHOW AND LABEL | | | PROPOSED UTILITY EASEMENT FOR IT. | | | -I COULD NOT FIND RECORD OF EAST-WEST COMPONENT OF 8 | | | INCH SAN PIPE ON SITE AS SHOWN ON UTILITY PLAN. PLEASE | | | VERIFY PLAN SHOWS IT CORRECTLY. | | | -LANDSCAPE PLANS NOT INCLUDED IN RECENT RESUBMITTAL | | | PACKAGE. PLEASE SUBMIT AND VERIFY THERE ARE NO | | | CONFLICTS BETWEEN UTILITIES AND LANDSCAPING. | | | |
|
|
| Review Stop |
ENG - PPRC |
ENGINEERING - PPRC |
| Rev No |
3 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
ENG - PPRC |
ENGINEERING - PPRC |
| Rev No |
2 |
Status |
F |
Date |
04-08-2021 |
|
|
Cont ID |
|
| Sent By |
rrossano |
Date |
04-08-2021 |
Time |
|
Rev Time |
0.00 |
| Received By |
rrossano |
Date |
04-08-2021 |
Time |
|
Sent To |
|
|
| Notes |
| 2021-04-08 17:46:36 | Z21010014 - PB MEDICAL - 6910 S DIXIE? 4-7-2021 RESUB | | | | | | COMMENTS PER RICK ROSSANO, PROJECT COORDINATOR, | | | ENGINEERING SERVICES DEPARTMENT DIRECT: (561) 494-1098 | | | [email protected] | | | | | | 1. PROVIDE CALCULATIONS ON PLANS OF EXISTING AND | | | PROPOSED DEMANDS FOR WATER & SEWER (AVERAGE, MAXIMUM | | | AND PEAK) AND FIRE FLOW DEMANDS. CALCULATIONS SHALL BE | | | PER FAC 64E-6 FOR SEWER AND PER FAC 64-E.008 FOR WATER. | | | 2. PROVIDE CCTV VIDEO OF EXISTING SANITARY SEWER IN | | | ALLEY. (CCTV IS CONDITION OF SITE PLAN APPROVAL). | | | 3. PLEASE PROVIDE ENLARGED VIEW ON PLANS OF PROPOSED | | | LOCATION OF WATER METER AND BACKFLOW PREVENTION. | | | 4. COORDINATE WITH MARK HURLEY, FIELD CUSTOMER SERVICE | | | SUPERVISOR WITH CITY OF WPB PUBLIC UTILITIES, REGARDING | | | PLACEMENT OF BACKFLOW DEVICES AND WATER METERS. CONTACT | | | HIM AT 561-494-2262 OR [email protected] | | | 5. FOR ENGINEERING SUBMITTAL, SHOW PAVEMENT RESTORATION | | | AT SCALE PER STANDARD DETAIL GC-8. | | | | | | THE FOLLOWING COMMENTS ARE FROM MARK HURLEY, FIELD | | | CUSTOMER SERVICE SUPERVISOR, WPB PUBLIC UTILITIES, | | | PLEASE CONTACT 561-494-2262 OR [email protected]: | | | | | | PLEASE RESPOND TO THE COMMENTS BELOW IN WRITING THAT | | | WERE FROM PRIOR SUBMITTAL REVIEW: | | | | | | -EXISTING BACKFLOW ASSEMBLY FOR DOMESTIC WATER DOES NOT | | | APPEAR TO BE LEAD-FREE COMPLIANT. RECOMMEND REPLACING | | | TO LEAD-FREE COMPLIANT ASSEMBLY. | | | -PROPOSED FIRELINE WATER SERVICE LOCATION IS ONLY | | | ACCEPTABLE IF ALLEY R/W VACATION REQUEST IS APPROVED. | | | -PAVEMENT RESTORATION BOUNDARIES ON BREVARD AVE FOR THE | | | UTILITY WORK APPEARS TO BE SMALLER THAN REQUIRED | | | DIMENSIONS OUTLINED IN THE PAVEMENT RESTORATION | | | STANDARD DETAILS. | | | -ENGINEERING PLAN SHOULD HAVE DATUM INFORMATION AND | | | CONVERSION EQUATION. | | | -ADD WATER DEMAND CALCULATIONS TO ENGINEERING PLAN | | | ALONG WITH THE EXISTING WATER METER AND WATER SERVICE | | | SIZE. | | | -PROPOSED UTILITY EASEMENT IS NOT LABELED ON | | | ENGINEERING PLAN. | | | -FOR FORMAL ENGINEERING SUBMITTAL, PLEASE ADD PROPERTY | | | ADDRESS TO ENGINEERING PLAN AND ADD NOTE THAT BACKFLOW | | | ASSEMBLIES NEED 18INCHES CLEARANCE AROUND THEM. ALSO | | | LABEL FIRELINE GATE VALVE - (FIRELINE POINT OF | | | SERVICE), AND SHOW FRANCHISE UTILITIES NEAR FIRELINE | | | TAP. | | | -WILL IRRIGATION WATER BE USED FROM EXISTING WATER | | | SERVICE OR WILL ANOTHER WATER SERVICE BE NEEDED? | | | | | | NEW COMMENTS (PLEASE RESPOND IN WRITING): | | | | | | -BACKFLOW ASSEMBLIES MUST BE LOCATED ON PRIVATE | | | PROPERTY AND MAY NOT EXTEND INTO UTILITY EASEMENTS OR | | | RIGHT OF WAYS. | | | -DDCV LOCATION IS EXCESSIVELY FAR FROM PROPERTY LINE | | | STANDARDS. WOULD LIKE TO REVIEW ALTERNATE LOCATIONS | | | WITH PLAN DESIGNER. | | | -DID NOT SEE ANY TREES ON PLANS, BUT COULD NOT FIND A | | | DEDICATED LANDSCAPING PLAN IN SUBMITTAL PACKAGE. IS | | | THERE SEPARATE LANDSCAPING PLAN, AND ARE THERE ANY | | | CONFLICTS BETWEEN UTILITIES AND TREES? | | | -FOR FORMAL ENGINEERING SUBMITTAL: LABEL THE DOMESTIC | | | WATER SERVICE LINE PIPE WITH MATERIAL TYPE AND SIZE, | | | LABEL THE PIPING BETWEEN THE WATER METER AND BACKFLOW | | | ASSEMBLY AND MAKE SURE IT COMPLIES WITH SMALL BACKFLOW | | | ASSEMBLY STANDARD DETAIL, ADD WATER METER SIZE TO | | | LABEL. | | | -PLEASE LABEL 8 INCH SAN PIPE ON SITE AS PRIVATE OR | | | CITY. IF WILL BE CITY-OWNED, THEN SHOW AND LABEL | | | PROPOSED UTILITY EASEMENT FOR IT. | | | -I COULD NOT FIND RECORD OF EAST-WEST COMPONENT OF 8 | | | INCH SAN PIPE ON SITE AS SHOWN ON UTILITY PLAN. PLEASE | | | VERIFY PLAN SHOWS IT CORRECTLY. | | | | | | |
|
|
| Review Stop |
ENG - PPRC |
ENGINEERING - PPRC |
| Rev No |
1 |
Status |
F |
Date |
04-08-2021 |
|
|
Cont ID |
|
| Sent By |
rrossano |
Date |
04-08-2021 |
Time |
|
Rev Time |
|
| Received By |
rrossano |
Date |
04-08-2021 |
Time |
|
Sent To |
|
|
| Notes |
| 2021-04-08 17:49:20 | THESE COMMENTS WERE PREVIOUSLY ENTERED UNDER ROW | | | ABANDONMENT PERMIT Z20010014: | | | | | | 1. THE CITY OF WEST PALM BEACH HAS A NUMBER OF | | | REGULATIONS AND PERMIT REQUIREMENTS WHICH DIRECTLY | | | AFFECT THE DEVELOPMENT AND INSTALLATION OF WATER AND | | | WASTEWATER UTILITIES WITHIN THE CITY. TO VIEW | | | DEVELOPMENT PERMIT SUBMITTAL REQUIREMENTS AND OTHER | | | ENGINEERING RELATED DOCUMENTS, OPEN A BROWSER IN CHROME | | | AND GO TO: WWW.WPB.ORG/ENGDOCS . TO LOGIN, UNDER | | | ?EMAIL? ENTER [email protected] ; UNDER ?PASSWORD? ENTER | | | SIMPLE321# | | | THERE ARE 4 PAGES OF AVAILABLE ENGINEERING DOCUMENTS | | | FOR YOUR USE. | | | 2. CODE OF ORDINANCES, CITY OF WEST PALM BEACH, | | | FLORIDA, CODIFIED THROUGH ORD. NO. 4183-08, ADOPTED | | | SEPT. 22, 2008. (SUPPLEMENT NO. 18) CHAPTER 90 | | | UTILITIES, ARTICLE I. SEC. 90-7. | | | POLICY REGARDING EXTENSION OF WATER OR SEWER SERVICE | | | FACILITIES OF THE CITY: | | | THE WATER AND WASTEWATER SERVICE AGREEMENTS AND THE | | | CONSTRUCTION PERMITS ADDRESS RESERVATION OF CAPACITY | | | BASED ON USAGE, METER SIZE AND FEES, DESIGN STANDARDS, | | | BACKFLOW PREVENTION, FIRE SERVICE AND IRRIGATION. | | | 3. AS OF DECEMBER 20, 2015, THE CITY OF WEST PALM BEACH | | | CROSS-CONNECTION CONTROL MANUAL HAS BEEN REVISED, | | | STATING "ALL BACKFLOW DEVICES MUST BE LEAD-FREE". FOR | | | MORE INFORMATION, OPEN A BROWSER IN CHROME AND GO TO: | | | WWW.WPB.ORG/ENGDOCS .TO LOGIN, UNDER ?EMAIL? ENTER | | | [email protected] ; UNDER ?PASSWORD? ENTER SIMPLE321# | | | CROSS-CONNECTION CONTROL MANUAL IS ON PAGE 4. | | | 4. PLEASE SUBMIT A FORMAL AS-BUILT REQUEST FOR ALL CITY | | | OF WEST PALM BEACH-OWNED UTILITIES WITHIN THE PUBLIC | | | RIGHT OF WAY FOR THE ENTIRE EXTENT OF THE LIMITS OF | | | YOUR PROJECT. IDENTIFY TYPE OF UTILITY, LOCATION, PIPE | | | MATERIAL, AGE AND SIZE. PLEASE CONTACT JANICE TARBILL | | | IN THE WPB ENGINEERING SERVICES DEPARTMENT AT | | | [email protected] OR 561-494-1040 FOR FURTHER | | | ASSISTANCE. | | | 5. PLANS SHALL SHOW PROPOSED LOCATIONS AND DIMENSIONS | | | OF ALL WATER, STORMWATER, AND SANITARY AND SEWER LINES, | | | INCLUDING STUBS TO EACH PROPERTY LINE FOR WATER AND | | | SANITARY SEWERS, THE MAKE AND MODEL OF ALL VALVES, | | | METERS, AND OTHERS DEVICES TO BE INSTALLED ON THE | | | SYSTEM, CATCH BASINS, CULVERTS, DITCHES INCLUDING | | | GRADES, PIPES SIZES, MATERIALS, ELEVATIONS, | | | ASSUMPTIONS, CALCULATIONS, INVERT ELEVATIONS FOR ALL | | | INLETS AND MANHOLES AND PROFILES OF SANITARY SEWER | | | LINES. ALL AVAILABLE ELEVATION SHALL BE SHOWN ON THE | | | PROFILE VIEW. DIRECTION OF FLOW SHALL BE SHOWN ON PLAN | | | VIEW ON PLAN VIEW FOR ALL SANITARY AND STORM SEWERS. | | | PLEASE SHOW SLOPE % ON ALL SANITARY LINES AND CALL OUT | | | MATERIAL. ADDITIONALLY, PLAN VIEW SHALL SHOW ALL | | | EXISTING AND PROPOSED UNDERGROUND UTILITY LAYOUT, | | | INCLUDING FIBER OPTIC, ELECTRIC, GAS, AND CABLEVISION & | | | TELECOMMUNICATION FACILITIES LOCATED ON THE | | | RIGHT-OF-WAY. PROVIDE PROFILE AND CLEARANCES AT ALL | | | UTILITY CROSSINGS. | | | 6. CUT AND CAP UTILITIES NOT IN USE, AND REMOVE ANY | | | ABANDONED UTILITY LINES LARGER THAN 2 INCHES FROM CITY | | | ROW. | | | 7. PLEASE SUBMIT COMPLETED LOS ANALYSIS SUMMARY TABLE | | | DIRECTLY TO ENGINEERING (SHEET 33 OF CITY OF WPB | | | DEVELOPMENT APPLICATION). | | | 8. PROVIDE CALCULATIONS ON PLANS OF EXISTING AND | | | PROPOSED DEMANDS FOR WATER & SEWER (AVERAGE, MAXIMUM | | | AND PEAK) AND FIRE FLOW DEMANDS. CALCULATIONS SHALL BE | | | PER FAC 64E-6 FOR SEWER AND PER FAC 64-E.008 FOR WATER. | | | 9. SHOW VERTICAL DATUM AND DATUM CONVERSION INFORMATION | | | (NAVD 88 AND NGVD 29). | | | 10. PROVIDE CCTV VIDEO OF EXISTING SANITARY SEWER IN | | | ALLEY. | | | 11. PLEASE PROVIDE CALCULATIONS OF REVISED PERVIOUS AND | | | IMPERVIOUS CALCULATIONS FOR THE PROPOSED IMPACTED | | | AREAS. | | | 12. PROVIDE ONSITE CLEANOUTS NEAR PROPERTY LINE FOR | | | PROPOSED SANITARY LATERALS. | | | 13. PLEASE LABEL WATER LINES AS PRIVATE WHERE | | | APPLICABLE. | | | 14. PLEASE PROVIDE ENLARGED VIEW ON PLANS OF PROPOSED | | | LOCATION OF WATER METER AND BACKFLOW PREVENTION. | | | 15. COORDINATE WITH MARK HURLEY, FIELD CUSTOMER SERVICE | | | SUPERVISOR WITH CITY OF WPB PUBLIC UTILITIES, REGARDING | | | PLACEMENT OF BACKFLOW DEVICES AND WATER METERS. CONTACT | | | HIM AT 561-494-2262 OR [email protected] | | | 16. PROVIDE DEDICATED UTILITY EASEMENTS TO ALLOW ACCESS | | | FOR CITY PERSONNEL TO PROPOSED UTILITY WATER METERS. | | | 17. FOR ENGINEERING SUBMITTAL, SHOW PAVEMENT | | | RESTORATION AT SCALE PER STANDARD DETAIL. | | | 18. CONFIRM IF THERE ARE ANY PROPOSED DRAINAGE | | | IMPROVEMENTS. | | | | | | | | | | | | THE FOLLOWING COMMENTS ARE FROM MARK HURLEY, FIELD | | | CUSTOMER SERVICE SUPERVISOR, WPB PUBLIC UTILITIES, | | | PLEASE CONTACT 561-494-2262 OR [email protected]: | | | -EXISTING BACKFLOW ASSEMBLY FOR DOMESTIC WATER DOES NOT | | | APPEAR TO BE LEAD-FREE COMPLIANT. RECOMMEND REPLACING | | | TO LEAD-FREE COMPLIANT ASSEMBLY. | | | -PROPOSED FIRELINE WATER SERVICE LOCATION IS ONLY | | | ACCEPTABLE IF ALLEY R/W VACATION REQUEST IS APPROVED. | | | -PAVEMENT RESTORATION BOUNDARIES ON BREVARD AVE FOR THE | | | UTILITY WORK APPEARS TO BE SMALLER THAN REQUIRED | | | DIMENSIONS OUTLINED IN THE PAVEMENT RESTORATION | | | STANDARD DETAILS. | | | -ENGINEERING PLAN SHOULD HAVE DATUM INFORMATION AND | | | CONVERSION EQUATION. | | | -ADD WATER DEMAND CALCULATIONS TO ENGINEERING PLAN | | | ALONG WITH THE EXISTING WATER METER AND WATER SERVICE | | | SIZE. | | | -PROPOSED UTILITY EASEMENT IS NOT LABELED ON | | | ENGINEERING PLAN. | | | -FOR FORMAL ENGINEERING SUBMITTAL, PLEASE ADD PROPERTY | | | ADDRESS TO ENGINEERING PLAN AND ADD NOTE THAT BACKFLOW | | | ASSEMBLIES NEED 18INCHES CLEARANCE AROUND THEM. ALSO | | | LABEL FIRELINE GATE VALVE ? (FIRELINE POINT OF | | | SERVICE), AND SHOW FRANCHISE UTILITIES NEAR FIRELINE | | | TAP. | | | -WILL IRRIGATION WATER BE USED FROM EXISTING WATER | | | SERVICE OR WILL ANOTHER WATER SERVICE BE NEEDED? | | | | | | FEEL FREE TO CONTACT US IF YOU HAVE ANY QUESTIONS OR | | | CONCERNS, THANKS. | | | RICK ROSSANO, PROJECT COORDINATOR, ENGINEERING SERVICES | | | DEPARTMENT | | | DIRECT: (561) 494-1098 [email protected] | | | | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
02-05-2021 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
02-05-2021 |
Time |
12:07 |
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
02-05-2021 |
Time |
12:04 |
Sent To |
|
|
| Notes |
| 2021-02-05 12:07:04 | THE FOLLOWING COMMENTS WERE SUBMITTED BY PETER LEDUC, | | | FIRE MARSHAL, BUREAU OF FIRE PREVENTION, WEST PALM | | | BEACH FIRE RESCUE. | | | | | | THIS REVIEW CAN ONLY BE CONSIDERED PRELIMINARY AS THE | | | DRAWINGS THAT WERE REVIEWED WERE NOT COMPLETE. | | | ADDITIONAL COMMENTS CAN BE EXPECTED WHEN FULL DRAWINGS | | | ARE SUBMITTED FOR PERMIT. | | | | | | THE FIRE PREVENTION BUREAU HAS NO OBJECTIONS TO THE | | | PROPOSED PROJECT.THE FOLLOWING COMMENTS ARE INTENDED TO | | | PROVIDE GUIDANCE FOR BUILDING PLAN SUBMITTAL. | | | | | | 1. CONSTRUCTION, DEMOLITION, AND RENOVATION TO COMPLY | | | WITH NFPA 241. EXTRA ATTENTION SHALL BE GIVEN TO THE | | | PERMITTING AND LOCATION OF CONSTRUCTION TRAILERS. A | | | PERMIT IS REQUIRED FOR ANY CONSTRUCTION TRAILER RELATED | | | TO THIS PROJECT. SEPARATION DISTANCES FROM MAIN | | | STRUCTURES AS WELL AS OTHER TRAILERS SHALL BE CLOSELY | | | MONITORED FOR THE REQUIREMENTS OF FIRE SPRINKLER | | | PROTECTION. | | | | | | 2. SITE ACCESS AND EXIT POINTS ARE TO BE CLEARLY | | | IDENTIFIED AND MAINTAINED FOR EMERGENCY VEHICLES DURING | | | ALL CONSTRUCTION ACTIVITIES. | | | | | | 3. THE BUILDING ADDRESS SHALL BE CLEARLY VISIBLE FROM | | | ALL ACCESS ROADWAYS, INCLUDING DURING CONSTRUCTION. | | | ADDRESS NUMBERS SHALL CONTRAST WITH THEIR BACKGROUND | | | AND SHALL NOT BE LESS THAN SIX (6) INCHES IN HEIGHT | | | WITH A ONE (1) INCH STROKE FOR ALL BUILDINGS. | | | | | | 4. DURING CONSTRUCTION, TRASH AND DEBRIS IS TO BE | | | REMOVED FROM THE SITE DAILY OR MORE OFTEN TO REDUCE THE | | | ACCUMULATION OF POTENTIAL LIFE AND FIRE SAFETY HAZARDS. | | | | | | 5. THE CONSTRUCTION OF THE BUILDING SHALL COMPLY WITH | | | THE 7TH EDITION OF THE FLORIDA FIRE PREVENTION CODE, | | | INCLUDING NFPA 1 & 101, AND ALL ASSOCIATED FIRE CODES. | | | | | | 6. FOR PLAN REVIEW SUBMITTAL, PLEASE INCLUDE THE | | | OCCUPANCY TYPE, PER THE FLORIDA FIRE PREVENTION CODE, | | | AND WHETHER IT IS MIXED OR SEPARATED OCCUPANCY. | | | | | | 7. FOR PLAN REVIEW SUBMITTAL, PLEASE ENSURE THAT A FIRE | | | LOAD CALCULATION IS INCLUDED AND THAT ADEQUATE WATER | | | SUPPLY IS EXISTING OR WILL BE PROVIDED. | | | | | | 8. ALL EXISTING AND NEW FIRE HYDRANTS PLANNED FOR THIS | | | DEVELOPMENT SHALL BE CLEARLY INDICATED AND IDENTIFIED | | | ON THE PLAN AND CLOSELY COORDINATED WITH THE BUREAU OF | | | FIRE PREVENTION. | | | | | | 9. PROVIDE FOR A FIRE SPRINKLER AND/OR FIRE ALARM PER | | | THE APPLICABLE OCCUPANCY CODE. FOR ANY LIFE SAFETY | | | ENGINEERED SYSTEM, I.E FIRE SPRINKLER AND FIRE ALARM, | | | ENSURE THEY COMPLY WITH THE REQUIREMENTS OF FS 61G AND | | | SUBMITTED WITH THE MASTER PERMIT. | | | | | | 10. COMPLETE LIFE SAFETY PLANS FOR EACH OCCUPANCY SHALL | | | BE PROVIDED THAT ILLUSTRATE OCCUPANT LOADS, TRAVEL | | | DISTANCES, COMMON PATHS OF TRAVEL, DEAD-END CORRIDORS, | | | EXIT SIGNS, EMERGENCY LIGHTING, EXITS LEADING TO A | | | PUBLIC WAY, FIRE EXTINGUISHER LOCATIONS, AND ALL FIRE | | | SAFETY FEATURES AND EQUIPMENT. | | | | | | 11. IT IS HIGHLY RECOMMENDED (REQUIRED WITH FIRE | | | SPRINKLER SYSTEM) THAT A KNOX BOX WITH KEYS FOR ENTRY | | | DOOR LOCKS BE PROVIDED FOR 24 HOUR EMERGENCY ACCESS. | | | | | | 12. THE BUREAU'S APPROVAL OF THIS SUBMITTED PROJECT | | | DOES NOT CONSTITUTE ITS FINAL REVIEW OR APPROVAL. | | | | | | 13. THE BUREAU SHALL REVIEW ALL SUBMITTED BUILDING | | | PLANS AT THE APPROPRIATE TIME AND IN ACCORDANCE WITH | | | THE REQUIREMENTS OF ALL APPLICABLE CODES AND STANDARDS. | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
3 |
Status |
P |
Date |
04-20-2021 |
|
|
Cont ID |
|
| Sent By |
rcaranci |
Date |
04-20-2021 |
Time |
13:34 |
Rev Time |
0.00 |
| Received By |
rcaranci |
Date |
04-20-2021 |
Time |
13:34 |
Sent To |
|
|
| Notes |
| 2021-04-20 13:35:15 | FROM: RAY CARANCI, SENIOR LANDSCAPE PLANNER | | | 561-822-1462 | | | PROJECT: 6910 S DIXIE Z21010014 | | | APRIL 20, 2021 | | | I HAVE REVIEWED THE ABOVE REFERENCED PETITION, AND | | | PROVIDE THE FOLLOWING COMMENTS: | | | | | | 1. SATISFIED. CORRECT THE TREE DISPOSITION PLAN TO SHOW | | | 300 SQ FT MITIGATION DUE FOR #11 FICUS BENJAMINA, A | | | CATEGORY 1 TREE, AND 100 SQ FT MITIGATION DUE FOR #25 | | | EUGENIA FOETIDA, A CATEGORY 3 TREE. REVISE TOTAL | | | MITIGATION DUE. | | | 2. SATISFIED. PROVIDE LOCATIONS FOR TREES WITHIN 10 | | | FEET OF THE PROPERTY LINE ON ADJACENT PARCELS AND | | | ADJUST SPACING OF PROPOSED TREES TO AVOID CANOPY | | | CONFLICTS PER SECTION 94-442(B) (2)Q. | | | | | | 3. SATISFIED. CORRECT THE REQUIRED OPEN SPACE TO 40% OF | | | THE LOT AREA UNDER LANDSCAPE REQUIREMENTS AND | | | RECALCULATE REQUIRED TREES, FLOWERING TREES AND SHRUBS. | | | WILL BE 16,096 SQ FT.AS SHOWN ON DATA CHART. | | | CORRECT THE CALCULATIONS TO BE SHADE TREES: 11, | | | FLOWERING TREES: 3, AND SHRUBS: 33. | | | SHOW PROVIDED TOTAL QUANTITIES. | | | | | | 4. SATISFIED. PROVIDE THE PERCENTAGE OF PALM | | | SUBSTITUTIONS FOR REQUIRED TREES NOT EXCEEDING 35% PER | | | SECTION 94-442(D). | | | | | | 5. SATISFIED. INDICATE THE 5 FOOT LANDSCAPE BUFFER | | | LOCATIONS ON THE SITE PLAN AND LANDSCAPE PLAN ADJACENT | | | TO ALL PROPERTY LINES FOR THE PARCEL. | | | | | | 6. SATISFIED. THE NONCONFORMING EAST BUFFER CAN BE | | | IMPROVED BY ELIMINATING THE WHEEL STOPS AND MOVING THE | | | CURB TO PROVIDE 16 FOOT PAVED STALL AND ADD PERVIOUS | | | OVERHANG AREA. THIS WILL ALSO HELP REDUCE THE | | | IMPERVIOUS AREA THAT IS VERY CLOSE TO THE LIMIT. CHECK | | | OTHER AREAS ALONG THE NORTH BUFFER FOR POSSIBLE | | | ADJUSTMENT. | | | | | | 7. SATISFIED. CHECK CALCULATIONS FOR THE REQUIRED TREES | | | FOR BUFFER SEGMENTS IN THE PERIMETER BUFFER REQUIREMENT | | | CHART AND LIST LINEAR FOOTAGE OF EACH PROPERTY LINE | | | SEGMENT MEASURED ALONG THE CENTERLINE OF EACH BUFFER, | | | ROUNDING UP FOR ANY PORTION LEFT AFTER DIVIDING BY THE | | | REQUIRED 30 FOOT LENGTHS. SOUTH BUFFER IS 6 TREES | | | REQUIRED, AND WEST BUFFER IS 5 TREES REQUIRED. SEE | | | SECTION 94-443 (B) FOR THE BUFFERS ADJACENT TO | | | NON-RESIDENTIAL AND PUBLIC THOROUGHFARES. | | | NORTH BUFFER REQUIRES 10 TREES FOR 276 FEET, SOUTH | | | BUFFER REQUIRES 8 TREES FOR 220 FEET, WEST BUFFER | | | REQUIRES 6 TREES FOR 157 FEET. DO NOT DEDUCT DRIVEWAYS | | | FROM BUFFER LENGTHS. | | | | | | | | | 8. SATISFIED. PROVIDE CALCULATION FOR BUFFER LENGTHS | | | WITH ACCESS DRIVEWAYS TO SHOW THEY DO NOT EXCEED 25% | | | INTERRUPTION FOR VEHICULAR ACCESS AS REQUIRED BY | | | SECTION 94-443(B). | | | | | | 9. SATISFIED. PROVIDE THE REQUIRED AND PROVIDED LINEAR | | | FOOTAGE OF LANDSCAPE AREA ADJACENT TO EACH BUILDING. | | | | | | 10. SATISFIED. ADD ANY EXISTING TREES AND PALMS TO THE | | | PLANT LIST AND COUNT THEM TOWARD THE REQUIRED TREES. | | | | | | 11. SATISFIED. SECTION 94-443(C)(3) REQUIRES THAT A | | | MINIMUM OF 75 PERCENT OF ALL TREES THAT ARE REQUIRED TO | | | BE PLANTED WITHIN THE INTERIOR OF AN OFF STREET PARKING | | | AREA SHALL BE CATEGORY 1 SHADE TREES. SHOW THE REQUIRED | | | NUMBER OF TREES AND THE PERCENTAGE OF CATEGORY 1 TREES | | | PROVIDED FOR THE REQUIRED LANDSCAPE AREAS. | | | | | | 12. SATISFIED. PROVIDE AN EXHIBIT SHOWING THE PARKING | | | AREA SURFACE CALCULATIONS, PARKING SPACE AREAS AND | | | LANDSCAPE AREAS PROVIDED TO DEMONSTRATE COMPLIANCE WITH | | | SECTIONS 94-443 (C)(3) AND (4), FOLLOWING THE AREA | | | CLASSIFICATIONS AS SHOWN IN FIGURE XIV-1. | | | ? PARKING SPACES SHADED AS ONE AREA, SHOW TOTAL SPACES | | | TIMES 10 SQ FT PER SPACE. PROVIDE TOTAL | | | ? ALL OTHER PAVED AREAS SHADED DIFFERENTLY AND TOTAL | | | SQUARE FOOTAGE. DIVIDE BY 100 AND MULTIPLY BY 4 SQ FT. | | | PROVIDE TOTAL. | | | ? TOTAL THESE 2 SQUARE FOOTAGE AMOUNTS FOR THE REQUIRED | | | SQUARE FOOTAGE. | | | ? SHOW ALL INTERIOR LANDSCAPE AREAS AS A DIFFERENT | | | SHADE AND SHOW PROVIDED SQUARE FOOTAGE. | | | | | | 13. SATISFIED. DIMENSION ALL INTERIOR AND TERMINAL | | | LANDSCAPE ISLANDS ON THE SITE PLAN TO SHOW THE MINIMUM | | | 8 FEET WIDTH OF THE LANDSCAPE AREA IS AT LEAST 8 FEET | | | FOR ALL NEW ISLANDS. TERMINAL ISLANDS ADJACENT TO A | | | LANDSCAPE BUFFER CAN COUNT THE 5 FEET OF BUFFER BUT | | | MUST ADD 3 FEET OF LANDSCAPE AREA TO ACHIEVE THE | | | REQUIRED 8 FEET WIDTH WITHIN CURB. | | | | | | 14. SATISFIED. TERMINAL LANDSCAPE ISLAND AND TREE IS | | | MISSING AT THE SOUTHEAST CORNER ADJACENT TO MADDOCK ST. | | | 15. SATISFIED. PROVIDE LOCATIONS AND SCREENING FOR ALL | | | ABOVE GROUND UTILITY VALVES, BACKFLOW PREVENTERS, A/C | | | UNITS, AND FPL TRANSFORMERS. | | | | | | 16. SATISFIED. PROVIDE THE PERCENTAGE TO BASED ON THE | | | PLANT LIST TO SHOW COMPLIANCE WITH SECTION 94-445 L. | | | PLANT SPECIES. A MINIMUM OF 60 PERCENT OF PLANT | | | MATERIAL ADDED SHALL BE FLORIDA NATIVE OR DROUGHT | | | TOLERANT SPECIES SELECTED FROM THE CITY LIST OR THE | | | LIST OF SPECIES IN THE MOST RECENT EDITION OF SOUTH | | | FLORIDA WATER MANAGEMENT DISTRICT WATERWISE SOUTH | | | FLORIDA LANDSCAPES. | | | | | | CONDITIONS OF APPROVAL | | | 1. PRIOR TO THE REMOVAL OR RELOCATION OF ANY TREES ON | | | THE PROPERTY, A TREE ALTERATION PERMIT SHALL BE | | | SUBMITTED, REVIEWED AND APPROVED BY THE DEVELOPMENT | | | SERVICES DEPARTMENT, PLANNING DIVISION. TREE #1 LIVE | | | OAK WILL BE EVALUATED AT TIME OF PERMIT APPLICATION TO | | | ASSURE THAT THE PAVING, CURB AND WALL CAN BE INSTALLED | | | WITHOUT HARMING THE TREE. | | | | | | 2. THE APPLICANT, SUCCESSORS AND ASSIGNS SHALL BE | | | RESPONSIBLE FOR THE MAINTENANCE OF THE ROAD RIGHT OF | | | WAY LANDSCAPING AND IRRIGATION ADJACENT TO THE | | | PROPERTY. THIS WILL BE THROUGH A SEPARATE MAINTENANCE | | | AGREEMENT WITH THE CITY. | | | | | | |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
2 |
Status |
F |
Date |
03-18-2021 |
|
|
Cont ID |
|
| Sent By |
rcaranci |
Date |
03-18-2021 |
Time |
12:20 |
Rev Time |
0.00 |
| Received By |
rcaranci |
Date |
03-18-2021 |
Time |
12:20 |
Sent To |
|
|
| Notes |
| 2021-03-18 12:23:47 | FROM: RAY CARANCI, SENIOR LANDSCAPE PLANNER | | | 561-822-1462 | | | PROJECT: 6910 S DIXIE Z21010014 | | | MARCH 18, 2021 | | | I HAVE REVIEWED THE ABOVE REFERENCED PETITION, AND | | | PROVIDE THE FOLLOWING COMMENTS: | | | | | | 1. SATISFIED. CORRECT THE TREE DISPOSITION PLAN TO SHOW | | | 300 SQ FT MITIGATION DUE FOR #11 FICUS BENJAMINA, A | | | CATEGORY 1 TREE, AND 100 SQ FT MITIGATION DUE FOR #25 | | | EUGENIA FOETIDA, A CATEGORY 3 TREE. REVISE TOTAL | | | MITIGATION DUE. | | | 2. SATISFIED. PROVIDE LOCATIONS FOR TREES WITHIN 10 | | | FEET OF THE PROPERTY LINE ON ADJACENT PARCELS AND | | | ADJUST SPACING OF PROPOSED TREES TO AVOID CANOPY | | | CONFLICTS PER SECTION 94-442(B) (2)Q. | | | | | | 3. PARTIALLY SATISFIED. CORRECT THE REQUIRED OPEN SPACE | | | TO 40% OF THE LOT AREA UNDER LANDSCAPE REQUIREMENTS AND | | | RECALCULATE REQUIRED TREES, FLOWERING TREES AND SHRUBS. | | | WILL BE 16,096 SQ FT.AS SHOWN ON DATA CHART. | | | CORRECT THE CALCULATIONS TO BE SHADE TREES: 11, | | | FLOWERING TREES: 3, AND SHRUBS: 33. | | | SHOW PROVIDED TOTAL QUANTITIES. | | | | | | 4. SATISFIED. PROVIDE THE PERCENTAGE OF PALM | | | SUBSTITUTIONS FOR REQUIRED TREES NOT EXCEEDING 35% PER | | | SECTION 94-442(D). | | | | | | 5. SATISFIED. INDICATE THE 5 FOOT LANDSCAPE BUFFER | | | LOCATIONS ON THE SITE PLAN AND LANDSCAPE PLAN ADJACENT | | | TO ALL PROPERTY LINES FOR THE PARCEL. | | | | | | 6. SATISFIED. THE NONCONFORMING EAST BUFFER CAN BE | | | IMPROVED BY ELIMINATING THE WHEEL STOPS AND MOVING THE | | | CURB TO PROVIDE 16 FOOT PAVED STALL AND ADD PERVIOUS | | | OVERHANG AREA. THIS WILL ALSO HELP REDUCE THE | | | IMPERVIOUS AREA THAT IS VERY CLOSE TO THE LIMIT. CHECK | | | OTHER AREAS ALONG THE NORTH BUFFER FOR POSSIBLE | | | ADJUSTMENT. | | | | | | 7. PARTIALLY SATISFIED. CHECK CALCULATIONS FOR THE | | | REQUIRED TREES FOR BUFFER SEGMENTS IN THE PERIMETER | | | BUFFER REQUIREMENT CHART AND LIST LINEAR FOOTAGE OF | | | EACH PROPERTY LINE SEGMENT MEASURED ALONG THE | | | CENTERLINE OF EACH BUFFER, ROUNDING UP FOR ANY PORTION | | | LEFT AFTER DIVIDING BY THE REQUIRED 30 FOOT LENGTHS. | | | SOUTH BUFFER IS 6 TREES REQUIRED, AND WEST BUFFER IS 5 | | | TREES REQUIRED. SEE SECTION 94-443 (B) FOR THE BUFFERS | | | ADJACENT TO NON-RESIDENTIAL AND PUBLIC THOROUGHFARES. | | | NORTH BUFFER REQUIRES 10 TREES FOR 276 FEET, SOUTH | | | BUFFER REQUIRES 8 TREES FOR 220 FEET, WEST BUFFER | | | REQUIRES 6 TREES FOR 157 FEET. DO NOT DEDUCT DRIVEWAYS | | | FROM BUFFER LENGTHS. | | | | | | | | | 8. SATISFIED. PROVIDE CALCULATION FOR BUFFER LENGTHS | | | WITH ACCESS DRIVEWAYS TO SHOW THEY DO NOT EXCEED 25% | | | INTERRUPTION FOR VEHICULAR ACCESS AS REQUIRED BY | | | SECTION 94-443(B). | | | | | | 9. SATISFIED. PROVIDE THE REQUIRED AND PROVIDED LINEAR | | | FOOTAGE OF LANDSCAPE AREA ADJACENT TO EACH BUILDING. | | | | | | 10. SATISFIED. ADD ANY EXISTING TREES AND PALMS TO THE | | | PLANT LIST AND COUNT THEM TOWARD THE REQUIRED TREES. | | | | | | 11. SATISFIED. SECTION 94-443(C)(3) REQUIRES THAT A | | | MINIMUM OF 75 PERCENT OF ALL TREES THAT ARE REQUIRED TO | | | BE PLANTED WITHIN THE INTERIOR OF AN OFF STREET PARKING | | | AREA SHALL BE CATEGORY 1 SHADE TREES. SHOW THE REQUIRED | | | NUMBER OF TREES AND THE PERCENTAGE OF CATEGORY 1 TREES | | | PROVIDED FOR THE REQUIRED LANDSCAPE AREAS. | | | | | | 12. SATISFIED. PROVIDE AN EXHIBIT SHOWING THE PARKING | | | AREA SURFACE CALCULATIONS, PARKING SPACE AREAS AND | | | LANDSCAPE AREAS PROVIDED TO DEMONSTRATE COMPLIANCE WITH | | | SECTIONS 94-443 (C)(3) AND (4), FOLLOWING THE AREA | | | CLASSIFICATIONS AS SHOWN IN FIGURE XIV-1. | | | ? PARKING SPACES SHADED AS ONE AREA, SHOW TOTAL SPACES | | | TIMES 10 SQ FT PER SPACE. PROVIDE TOTAL | | | ? ALL OTHER PAVED AREAS SHADED DIFFERENTLY AND TOTAL | | | SQUARE FOOTAGE. DIVIDE BY 100 AND MULTIPLY BY 4 SQ FT. | | | PROVIDE TOTAL. | | | ? TOTAL THESE 2 SQUARE FOOTAGE AMOUNTS FOR THE REQUIRED | | | SQUARE FOOTAGE. | | | ? SHOW ALL INTERIOR LANDSCAPE AREAS AS A DIFFERENT | | | SHADE AND SHOW PROVIDED SQUARE FOOTAGE. | | | | | | 13. SATISFIED. DIMENSION ALL INTERIOR AND TERMINAL | | | LANDSCAPE ISLANDS ON THE SITE PLAN TO SHOW THE MINIMUM | | | 8 FEET WIDTH OF THE LANDSCAPE AREA IS AT LEAST 8 FEET | | | FOR ALL NEW ISLANDS. TERMINAL ISLANDS ADJACENT TO A | | | LANDSCAPE BUFFER CAN COUNT THE 5 FEET OF BUFFER BUT | | | MUST ADD 3 FEET OF LANDSCAPE AREA TO ACHIEVE THE | | | REQUIRED 8 FEET WIDTH WITHIN CURB. | | | | | | 14. SATISFIED. TERMINAL LANDSCAPE ISLAND AND TREE IS | | | MISSING AT THE SOUTHEAST CORNER ADJACENT TO MADDOCK ST. | | | 15. SATISFIED. PROVIDE LOCATIONS AND SCREENING FOR ALL | | | ABOVE GROUND UTILITY VALVES, BACKFLOW PREVENTERS, A/C | | | UNITS, AND FPL TRANSFORMERS. | | | | | | 16. SATISFIED. PROVIDE THE PERCENTAGE TO BASED ON THE | | | PLANT LIST TO SHOW COMPLIANCE WITH SECTION 94-445 L. | | | PLANT SPECIES. A MINIMUM OF 60 PERCENT OF PLANT | | | MATERIAL ADDED SHALL BE FLORIDA NATIVE OR DROUGHT | | | TOLERANT SPECIES SELECTED FROM THE CITY LIST OR THE | | | LIST OF SPECIES IN THE MOST RECENT EDITION OF SOUTH | | | FLORIDA WATER MANAGEMENT DISTRICT WATERWISE SOUTH | | | FLORIDA LANDSCAPES. | | | | | | CONDITIONS OF APPROVAL | | | 1. PRIOR TO THE REMOVAL OR RELOCATION OF ANY TREES ON | | | THE PROPERTY, A TREE ALTERATION PERMIT SHALL BE | | | SUBMITTED, REVIEWED AND APPROVED BY THE DEVELOPMENT | | | SERVICES DEPARTMENT, PLANNING DIVISION. | | | | | | | | | 2. THE APPLICANT, SUCCESSORS AND ASSIGNS SHALL BE | | | RESPONSIBLE FOR THE MAINTENANCE OF THE ROAD RIGHT OF | | | WAY LANDSCAPING AND IRRIGATION ADJACENT TO THE | | | PROPERTY. THIS WILL BE THROUGH A SEPARATE MAINTENANCE | | | AGREEMENT WITH THE CITY. | | | |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
1 |
Status |
F |
Date |
02-08-2021 |
|
|
Cont ID |
|
| Sent By |
rcaranci |
Date |
02-08-2021 |
Time |
16:34 |
Rev Time |
0.00 |
| Received By |
rcaranci |
Date |
02-08-2021 |
Time |
16:34 |
Sent To |
|
|
| Notes |
| 2021-02-08 16:34:34 | FROM: RAY CARANCI, SENIOR LANDSCAPE PLANNER | | | 561-822-1462 | | | PROJECT: 6910 S DIXIE Z21010014 | | | FEBRUARY 8, 2021 | | | I HAVE REVIEWED THE ABOVE REFERENCED PETITION, AND | | | PROVIDE THE FOLLOWING COMMENTS: | | | | | | 1. CORRECT THE TREE DISPOSITION PLAN TO SHOW 300 SQ FT | | | MITIGATION DUE FOR #11 FICUS BENJAMINA, A CATEGORY 1 | | | TREE, AND 100 SQ FT MITIGATION DUE FOR #25 EUGENIA | | | FOETIDA, A CATEGORY 3 TREE. REVISE TOTAL MITIGATION | | | DUE. | | | 2. PROVIDE LOCATIONS FOR TREES WITHIN 10 FEET OF THE | | | PROPERTY LINE ON ADJACENT PARCELS AND ADJUST SPACING OF | | | PROPOSED TREES TO AVOID CANOPY CONFLICTS PER SECTION | | | 94-442(B) (2)Q. | | | | | | 3. CORRECT THE REQUIRED OPEN SPACE TO 40% OF THE LOT | | | AREA UNDER LANDSCAPE REQUIREMENTS AND RECALCULATE | | | REQUIRED TREES, FLOWERING TREES AND SHRUBS. WILL BE | | | 16,096 SQ FT.AS SHOWN ON DATA CHART. | | | 4. PROVIDE THE PERCENTAGE OF PALM SUBSTITUTIONS FOR | | | REQUIRED TREES NOT EXCEEDING 35% PER SECTION 94-442(D). | | | | | | 5. INDICATE THE 5 FOOT LANDSCAPE BUFFER LOCATIONS ON | | | THE SITE PLAN AND LANDSCAPE PLAN ADJACENT TO ALL | | | PROPERTY LINES FOR THE PARCEL. | | | | | | 6. THE NONCONFORMING EAST BUFFER CAN BE IMPROVED BY | | | ELIMINATING THE WHEEL STOPS AND MOVING THE CURB TO | | | PROVIDE 16 FOOT PAVED STALL AND ADD PERVIOUS OVERHANG | | | AREA. THIS WILL ALSO HELP REDUCE THE IMPERVIOUS AREA | | | THAT IS VERY CLOSE TO THE LIMIT. CHECK OTHER AREAS | | | ALONG THE NORTH BUFFER FOR POSSIBLE ADJUSTMENT. | | | | | | 7. CHECK CALCULATIONS FOR THE REQUIRED TREES FOR BUFFER | | | SEGMENTS IN THE PERIMETER BUFFER REQUIREMENT CHART AND | | | LIST LINEAR FOOTAGE OF EACH PROPERTY LINE SEGMENT | | | MEASURED ALONG THE CENTERLINE OF EACH BUFFER, ROUNDING | | | UP FOR ANY PORTION LEFT AFTER DIVIDING BY THE REQUIRED | | | 30 FOOT LENGTHS. SOUTH BUFFER IS 6 TREES REQUIRED, AND | | | WEST BUFFER IS 5 TREES REQUIRED. SEE SECTION 94-443 (B) | | | FOR THE BUFFERS ADJACENT TO NON-RESIDENTIAL AND PUBLIC | | | THOROUGHFARES. | | | | | | 8. PROVIDE CALCULATION FOR BUFFER LENGTHS WITH ACCESS | | | DRIVEWAYS TO SHOW THEY DO NOT EXCEED 25% INTERRUPTION | | | FOR VEHICULAR ACCESS AS REQUIRED BY SECTION 94-443(B). | | | | | | 9. PROVIDE THE REQUIRED AND PROVIDED LINEAR FOOTAGE OF | | | LANDSCAPE AREA ADJACENT TO EACH BUILDING. | | | | | | 10. ADD ANY EXISTING TREES AND PALMS TO THE PLANT LIST | | | AND COUNT THEM TOWARD THE REQUIRED TREES. | | | | | | 11. SECTION 94-443(C)(3) REQUIRES THAT A MINIMUM OF 75 | | | PERCENT OF ALL TREES THAT ARE REQUIRED TO BE PLANTED | | | WITHIN THE INTERIOR OF AN OFF STREET PARKING AREA SHALL | | | BE CATEGORY 1 SHADE TREES. SHOW THE REQUIRED NUMBER OF | | | TREES AND THE PERCENTAGE OF CATEGORY 1 TREES PROVIDED | | | FOR THE REQUIRED LANDSCAPE AREAS. | | | | | | 12. PROVIDE AN EXHIBIT SHOWING THE PARKING AREA SURFACE | | | CALCULATIONS, PARKING SPACE AREAS AND LANDSCAPE AREAS | | | PROVIDED TO DEMONSTRATE COMPLIANCE WITH SECTIONS 94-443 | | | (C)(3) AND (4), FOLLOWING THE AREA CLASSIFICATIONS AS | | | SHOWN IN FIGURE XIV-1. | | | ? PARKING SPACES SHADED AS ONE AREA, SHOW TOTAL SPACES | | | TIMES 10 SQ FT PER SPACE. PROVIDE TOTAL | | | ? ALL OTHER PAVED AREAS SHADED DIFFERENTLY AND TOTAL | | | SQUARE FOOTAGE. DIVIDE BY 100 AND MULTIPLY BY 4 SQ FT. | | | PROVIDE TOTAL. | | | ? TOTAL THESE 2 SQUARE FOOTAGE AMOUNTS FOR THE REQUIRED | | | SQUARE FOOTAGE. | | | ? SHOW ALL INTERIOR LANDSCAPE AREAS AS A DIFFERENT | | | SHADE AND SHOW PROVIDED SQUARE FOOTAGE. | | | | | | 13. DIMENSION ALL INTERIOR AND TERMINAL LANDSCAPE | | | ISLANDS ON THE SITE PLAN TO SHOW THE MINIMUM 8 FEET | | | WIDTH OF THE LANDSCAPE AREA IS AT LEAST 8 FEET FOR ALL | | | NEW ISLANDS. TERMINAL ISLANDS ADJACENT TO A LANDSCAPE | | | BUFFER CAN COUNT THE 5 FEET OF BUFFER BUT MUST ADD 3 | | | FEET OF LANDSCAPE AREA TO ACHIEVE THE REQUIRED 8 FEET | | | WIDTH WITHIN CURB. | | | | | | 14. TERMINAL LANDSCAPE ISLAND AND TREE IS MISSING AT | | | THE SOUTHEAST CORNER ADJACENT TO MADDOCK ST. | | | 15. PROVIDE LOCATIONS AND SCREENING FOR ALL ABOVE | | | GROUND UTILITY VALVES, BACKFLOW PREVENTERS, A/C UNITS, | | | AND FPL TRANSFORMERS. | | | | | | 16. PROVIDE THE PERCENTAGE TO BASED ON THE PLANT LIST | | | TO SHOW COMPLIANCE WITH SECTION 94-445 L. PLANT | | | SPECIES. A MINIMUM OF 60 PERCENT OF PLANT MATERIAL | | | ADDED SHALL BE FLORIDA NATIVE OR DROUGHT TOLERANT | | | SPECIES SELECTED FROM THE CITY LIST OR THE LIST OF | | | SPECIES IN THE MOST RECENT EDITION OF SOUTH FLORIDA | | | WATER MANAGEMENT DISTRICT WATERWISE SOUTH FLORIDA | | | LANDSCAPES. | | | | | | CONDITIONS OF APPROVAL | | | 1. PRIOR TO THE REMOVAL OR RELOCATION OF ANY TREES ON | | | THE PROPERTY, A TREE ALTERATION PERMIT SHALL BE | | | SUBMITTED, REVIEWED AND APPROVED BY THE DEVELOPMENT | | | SERVICES DEPARTMENT, PLANNING DIVISION. | | | |
|
|
| Review Stop |
PARK |
PARKING |
| Rev No |
1 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
|
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
POLICE |
POLICE |
| Rev No |
1 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
|
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
PW |
PUBLIC WORKS |
| Rev No |
2 |
Status |
P |
Date |
03-03-2021 |
|
|
Cont ID |
|
| Sent By |
|
Date |
03-03-2021 |
Time |
|
Rev Time |
0.00 |
| Received By |
|
Date |
03-03-2021 |
Time |
|
Sent To |
|
|
| Notes |
| 2021-03-03 12:40:53 | NO FURTHER COMMENTS FROM DEPARTMENT OF PUBLIC WORKS. | | | | | | MATT HEJAZI | | | [email protected] | | | 561-822-2045 |
|
|
| Review Stop |
PW |
PUBLIC WORKS |
| Rev No |
1 |
Status |
F |
Date |
02-09-2021 |
|
|
Cont ID |
|
| Sent By |
|
Date |
02-09-2021 |
Time |
|
Rev Time |
|
| Received By |
|
Date |
02-09-2021 |
Time |
|
Sent To |
|
|
| Notes |
| 2021-02-09 11:33:19 | PLEASE PROVIDE THE DUMPSTER ENCLOSURE DETAIL. FOR A | | | FREESTANDING SITE DUMPSTER ENCLOSURE, THE ENCLOSURE | | | SHALL COMPLY WITH THE LATEST REVISION OF CITY OF WEST | | | PALM BEACH GENERAL CONSTRUCTION-GARBAGE ENCLOSURE | | | STANDARD, GC-7. | | | | | | MATT HEJAZI | | | DEPT. OF PUBLIC WORKS | | | [email protected] | | | 561-822-2045 |
|
|
| Review Stop |
STORM |
STORMWATER |
| Rev No |
4 |
Status |
P |
Date |
07-09-2021 |
|
|
Cont ID |
|
| Sent By |
tward |
Date |
07-09-2021 |
Time |
09:22 |
Rev Time |
0.00 |
| Received By |
tward |
Date |
07-09-2021 |
Time |
09:43 |
Sent To |
|
|
| Notes |
| 2021-07-09 09:42:46 | THE FOLLOWING COMMENTS ARE FROM THE REVIEW OF THE | | | 6/29/2021 PLAN SUBMITTAL: | | | | | | 1. EXFILTRATION TRENCH DETAIL AND CONTROL STRUCTURE | | | DETAIL WILL BE NEEDED WITH THE ENGINEERING PERMIT | | | SUBMITTAL. | | | | | | 2. LANDSCAPE PLANS WERE NOT SUBMITTED. THE CIVIL | | | ENGINEERING PLANS SHOW THE ELEVATED PLANTER ISLAND AT | | | THE SOUTH END OF THE FRONT OF THE BUILDING BEING | | | REMOVED FOR THE CONSTRUCTION OF THE VEHICLE TURN AROUND | | | AREA. THERE IS AN EXISTING TREE IN THE PLANTER THAT | | | WILL BE IMPACTED BY THE REMOVAL OF THE PLANTER WALL AND | | | CONSTRUCTION OF THE ASPHALT PAVEMENT. | | | | | | TRACY WARD, P.E. | | | SENIOR STORMWATER ENGINEER | | | ENGINEERING SERVICES DEPARTMENT | | | 561-494-1120 (O) | | | 561-351-0510 (M) | | | [email protected] |
|
|
| Review Stop |
STORM |
STORMWATER |
| Rev No |
3 |
Status |
F |
Date |
06-07-2021 |
|
|
Cont ID |
|
| Sent By |
tward |
Date |
06-07-2021 |
Time |
21:11 |
Rev Time |
0.00 |
| Received By |
tward |
Date |
06-07-2021 |
Time |
21:11 |
Sent To |
|
|
| Notes |
| 2021-06-07 21:11:36 | THE FOLLOWING COMMENTS ARE FROM THE REVIEW OF THE | | | 4/5/2021 SUBMITTAL REVIEW SET. | | | | | | 1. LABEL THE VERTICAL DATUM ON EVERY SHEET WITH | | | ELEVATION INFORMATION (PC-1, PGU-1, SP-1). PROVIDE THE | | | CONVERSION TO NGVD1929, THE CITY'S OFFICIAL VERTICAL | | | DATUM. [REPEAT COMMENT] | | | | | | 2. ENGINEERING PLAN DOES NOT MATCH THE SITE PLAN, E.G. | | | THE DRIVEWAY TO MADDOCK ST., THE CURBING AROUND THE | | | EXISTING PLANTER AT THE SOUTHWEST CORNER OF THE | | | BUILDING (EAST SIDE OF THE NO PARKING AREA). | | | | | | 3. PROPERLY SHOW THE MILL AND RESURFACING LIMITS ON | | | BREVARD AVE PER CITY DETAIL GC-8. [CAN BE ADDRESSED | | | DURING ENGINEERING PERMIT SUBMITTAL.] | | | | | | 4. SHOW REPLACEMENT OF SIDEWALK WITH 6" THICKNESS WHERE | | | DRIVEWAY APRONS ARE BEING WIDENED OR RELOCATED. [CAN BE | | | ADDRESSED DURING ENGINEERING PERMIT SUBMITTAL.] | | | | | | 5. MAXIMIZE THE STORAGE IN THE PROPOSED DRY RETENTION | | | AREA BY EXCAVATING THE BOTTOM TO OBTAIN 4:1 SIDE SLOPES | | | AND BOTTOM ELEVATION OF 12.0 FT NAVD. CROSS SECTIONS OF | | | THE RETENTIONA AREA WILL BE REQUIRED FOR THE | | | ENGINEERING PERMIT SUBMITTAL. | | | | | | 6. PROVIDE A PIPED CONNECTION BETWEEN THE ROOF DRAINS | | | FOR THE BUILDING ADDITION AND THE RETENTION AREA. | | | | | | 7. LOWER THE GRATE ELEVATION OF CATCH BASIN #3 AND | | | CREATE A DEPRESSION ACROSS THE DRIVEWAY TO ENSURE | | | STORMWATER RUNOFF FLOWS TO THE CATCH BASIN INSTEAD OF | | | ACROSS THE SIDEWALK. | | | | | | 8. STORM PIPE WITHIN THE RIGHT OF WAY TO BE MINIMUM 15" | | | RCP. | | | | | | 9. CREATE A SWALE IN THE LANDSCAPE BUFFER AT THE FORMER | | | WEST DRIVEWAY TO MADDOCK ST. CHANGE CURB INLET #1 TO A | | | DITCH BOTTOM INLET AND MOVE STRUCTURES NO. 1 AND NO. 2 | | | FURTHER EAST TO MAXIMIZE FLOW IN THE SWALE. | | | | | | 10. INDICATE IF THE EXISTING CURB BETWEEN THE LANDSCAPE | | | ISLAND AND THE WEST EDGE OF THE FORMER DRIVEWAY WILL | | | REMAIN OR BE REMOVED. INDICATE IF THE EXISTING CURB | | | ALONG THE BACK OF SIDEWALK WEST OF THE FORMER DRIVEWAY | | | WILL REMAIN, BE MODIFIED WITH CURB TRANSITION OR | | | EXTENDED TO THE EAST SIDE OF THE FORMER DRIVEWAY. | | | | | | 11. PROVIDE INLET PROTECTION FOR EXISTING DRAINAGE | | | STRUCTURES IN THE RIGHT-OF-WAY. {CAN BE ADDRESSED | | | DURING ENGINEERING PERMIT SUBMITTAL.] | | | | | | TRACY WARD, P.E. | | | SENIOR STORMWATER ENGINEER | | | ENGINEERING SERVICES DEPARTMENT | | | 561-494-1120 (O) | | | 561-351-0510 (M) | | | [email protected] | | | |
|
|
| Review Stop |
STORM |
STORMWATER |
| Rev No |
2 |
Status |
F |
Date |
03-26-2021 |
|
|
Cont ID |
|
| Sent By |
tward |
Date |
03-26-2021 |
Time |
14:41 |
Rev Time |
0.00 |
| Received By |
tward |
Date |
03-26-2021 |
Time |
15:23 |
Sent To |
|
|
| Notes |
| 2021-03-26 15:23:33 | THE FOLLOWING COMMENTS ARE FROM THE REVIEW OF THE | | | 3/2/2021 SUBMITTAL REVIEW SET. | | | | | | 1. LABEL THE VERTICAL DATUM ON EVERY SHEET WITH | | | ELEVATION INFORMATION. PROVIDE THE CONVERSION TO | | | NGVD1929, THE CITY'S OFFICIAL VERTICAL DATUM. | | | | | | 2. NARROW THE EAST SIDES OF THE ACCESS DRIVES TO | | | MADDOCK STREET AND WINTERS STREET SO THAT THE DRAINAGE | | | STRUCTURE DOES NOT NEED TO BE MODIFIED TO A DIFFERENT | | | TYPE OF TOP. | | | | | | 3. CREATE A STORMWATER DETENTION AREA IN THE PROPOSED | | | LANDSCAPE ISLAND IN THE SOUTHEAST CORNER OF THE SITE. | | | INCLUDE A RAISED DITCH BOTTOM INLET WITH A BAFFLE TO | | | MAXIMIZE STORAGE AND INSTALL MINIMUM 15" DIAMETER RCP | | | PIPE TO THE CATCH BASIN ON MADDOCK STREET. REGRADE | | | PAVEMENT TO FLOW INTO DETENTION AREA OR INSTALL TRENCH | | | DRAIN AT BACK OF SIDEWALK AND PIPE TO THE DETENTION | | | AREA. | | | | | | 4. WHY DOES THE NO PARKING AREA IN THE WEST PARKING LOT | | | EXTEND ALL OF THE WAY TO THE WEST PROPERTY LINE? FOR | | | DEAD END PARKING LOTS, JUST ONE PARKING SPACE NEEDS TO | | | BE STRIPED OUT AS A TURN AROUND SPACE. CONSIDER EITHER | | | EXPANDING THE LANDSCAPE ISLAND NEXT TO THE EXISTING | | | LIVE OAK TREE OR PUTTING BACK THE FOURTH PARKING SPACE | | | NEXT TO THE LIVE OAK TREE AND REMOVING THE SOUTH | | | PARKING SPACE ALONG THE EAST PROPERTY LINE AND | | | EXPANDING THE END TERMINAL ISLAND TO CREATE A BIGGER | | | STORMWATER DETENTION AREA. | | | | | | 5. CREATE SPREADER SWALE BEHIND THE SIDEWALK WHERE THE | | | DRIVEWAY TO MADDOCK STREET IS BEING REMOVED. | | | | | | 6. WILL THE EXISTING CURB ALONG THE BACK OF SIDEWALK ON | | | MADDOCK STREET BE EXTENDED ACROSS THE DRIVEWAY BEING | | | CLOSED AND CONNECT TO PLANTER RETAINING WALL? A LEVEL | | | TOP OF CURB WILL SPREAD OUT THE EXCESS RUNOFF FLOW ONTO | | | THE SIDEWALK. | | | | | | TRACY WARD, P.E. | | | SENIOR STORMWATER ENGINEER | | | ENGINEERING SERVICES DEPARTMENT | | | 561-494-1120 (O) | | | 561-351-0510 (M) | | | [email protected] |
|
|
| Review Stop |
STORM |
STORMWATER |
| Rev No |
1 |
Status |
F |
Date |
02-11-2021 |
|
|
Cont ID |
|
| Sent By |
tward |
Date |
02-11-2021 |
Time |
19:00 |
Rev Time |
0.00 |
| Received By |
tward |
Date |
02-11-2021 |
Time |
19:00 |
Sent To |
|
|
| Notes |
| 2021-02-11 19:00:18 | THIS IS A CONCEPTUAL LEVEL REVIEW. CONSTRUCTION LEVEL | | | DETAILS, DESIGN CALCULATIONS AND THE POLLUTION | | | PREVENTION PLAN WILL BE REVIEWED AS PART OF THE | | | ENGINEERING DEVELOPMENT APPROVAL AND BUILDING PERMIT | | | APPLICATION PROCESSES. | | | | | | THE FOLLOWING COMMENTS MUST BE ADDRESSED PRIOR TO SITE | | | PLAN APPROVAL: | | | | | | 1. THE CITY?S VERTICAL DATUM IS NATIONAL GEODETIC | | | VERTICAL DATUM OF 1929. THE CITY HAS ALLOWED THE USE OF | | | NAVD1988 PROVIDED THE CONVERSION TO NGVD1929 IS | | | PROVIDED ON THE PLAN. | | | | | | 2. ON EACH SHEET WITH ELEVATION INFORMATION LIST THE | | | VERTICAL DATUM AND THE CONVERSION EQUATION TO NGVD1929. | | | | | | 3. SHOW THE LIMITS OF MILL AND OVERLAY FOR THE TRENCH | | | CUTS IN THE PUBLIC RIGHT OF WAY. | | | | | | 4. S. DIXIE HWY IS MAINTAINED BY FDOT. ANY WORK WITHIN | | | THE S. DIXIE R/W WILL REQUIRE A PERMIT FROM FDOT. | | | | | | 5. SHOW PROPER PARKING LOT STRIPING (TWO 4? PARALLEL | | | STRIPES WITH 12-INCH GAP BETWEEN THEM AND CLOSED ON ONE | | | END) | | | | | | 6. STORMWATER WATER QUALITY TREATMENT MAY BE NEEDED. | | | CONSIDER INCORPORATING LOW IMPACT DEVELOPMENT IN THE | | | DESIGN. | | | | | | 7. IF ANY DRIVEWAY CONNECTIONS ARE CLOSED, REPLACE THE | | | DROP CURB WITH RAISED CURB (OR CURB AND GUTTER AS | | | APPLICABLE) IN THE RIGHT OF WAY. | | | | | | THE FOLLOWING COMMENTS MUST BE ADDRESSED PRIOR TO | | | ISSUANCE OF CONSTRUCTION AUTHORIZATION INCLUDING | | | BUILDING PERMITS AND ENGINEERING DEVELOPMENT APPROVAL. | | | | | | 1. AN ENGINEERING DEVELOPMENT APPROVAL APPLICATION MAY | | | BE REQUIRED FROM THE ENGINEERING SERVICES DEPARTMENT. | | | | | | 2. EROSION CONTROL PLAN AND DETAILS TO BE SUBMITTED | | | WITH THE ENGINEERING PERMIT APPLICATION. | | | | | | 4. DRAINAGE CALCULATIONS WILL BE REVIEWED WITH THE | | | ENGINEERING PERMIT APPLICATION. | | | | | | TRACY WARD, PE | | | SENIOR STORMWATER ENGINEER | | | ENGINEERING SERVICES DEPARTMENT | | | 561-494-1120 (O) | | | 561-351-0510 (M) | | | [email protected] | | | |
|
|
| Review Stop |
SURVEY |
SURVEYING |
| Rev No |
2 |
Status |
P |
Date |
05-12-2021 |
|
|
Cont ID |
|
| Sent By |
vnoel |
Date |
05-12-2021 |
Time |
06:49 |
Rev Time |
0.00 |
| Received By |
vnoel |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2021-05-12 06:50:00 | SEE COMMENTS UNDER Z21010015 |
|
|
| Review Stop |
SURVEY |
SURVEYING |
| Rev No |
1 |
Status |
F |
Date |
02-05-2021 |
|
|
Cont ID |
|
| Sent By |
vnoel |
Date |
02-05-2021 |
Time |
13:35 |
Rev Time |
|
| Received By |
vnoel |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2021-02-05 13:36:27 | SEE COMMENTS UNDER Z21010015. |
|
|
| Review Stop |
TRAFFIC |
TRAFFIC ENGINEERING |
| Rev No |
4 |
Status |
P |
Date |
06-04-2021 |
|
|
Cont ID |
|
| Sent By |
|
Date |
06-04-2021 |
Time |
|
Rev Time |
0.00 |
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2021-06-04 14:18:33 | NO FURTHER COMMENTS. | | | | | | VALERIO ORICCHIO | | | CITY TRANSPORTATION ENGINEER | | | 561-494-1092 | | | [email protected] | | | |
|
|
| Review Stop |
TRAFFIC |
TRAFFIC ENGINEERING |
| Rev No |
3 |
Status |
F |
Date |
04-26-2021 |
|
|
Cont ID |
|
| Sent By |
|
Date |
04-26-2021 |
Time |
|
Rev Time |
0.00 |
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2021-04-26 16:53:37 | TRAFFIC COMMENTS: | | | | | | 1) PROVIDE COUNTY TPS LETTER | | | | | | VALERIO ORICCHIO | | | CITY TRANSPORTATION ENGINEER | | | 561-494-1092 | | | [email protected] | | | |
|
|
| Review Stop |
TRAFFIC |
TRAFFIC ENGINEERING |
| Rev No |
2 |
Status |
F |
Date |
03-23-2021 |
|
|
Cont ID |
|
| Sent By |
|
Date |
03-23-2021 |
Time |
|
Rev Time |
0.00 |
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2021-03-23 19:43:18 | 1) PROVIDE COUNTY TPS LETTER | | | | | | VALERIO ORICCHIO | | | CITY TRANSPORTATION ENGINEER | | | 561-494-1092 | | | [email protected] | | | |
|
|
| Review Stop |
TRAFFIC |
TRAFFIC ENGINEERING |
| Rev No |
1 |
Status |
F |
Date |
02-10-2021 |
|
|
Cont ID |
|
| Sent By |
|
Date |
02-10-2021 |
Time |
|
Rev Time |
|
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2021-02-10 20:28:43 | TRAFFIC COMMENTS | | | 1) PROVIDE TRAFFIC STUDY/STATEMENT | | | 2) PROVIDE COUNTY TPS LETTER | | | | | | SITE COMMENTS | | | 1) ABANDON AND CLOSE THE DRIVEWAY ENTRANCE ON THE | | | SOUTH-WEST SIDE OF THE PROPERTY DUE TO THE PROXIMITY TO | | | THE DIXIE/MADDOCK INTERSECTION. MOREOVER, CITY CODE | | | SEC. 94-312 ONLY ALLOWS ONE ACCESS POINT ONTO EACH | | | RIGHT-OF-WAY FOR DEVELOPMENTS WITH LESS THAN 300 | | | PARKING SPACES. | | | | | | VALERIO ORICCHIO | | | CITY TRANSPORTATION ENGINEER | | | 561-494-1092 | | | [email protected] | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
4 |
Status |
P |
Date |
03-29-2022 |
|
|
Cont ID |
|
| Sent By |
kdefranc |
Date |
03-29-2022 |
Time |
12:23 |
Rev Time |
0.00 |
| Received By |
kdefranc |
Date |
03-29-2022 |
Time |
12:23 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
F |
Date |
04-27-2021 |
|
|
Cont ID |
|
| Sent By |
|
Date |
04-27-2021 |
Time |
|
Rev Time |
0.00 |
| Received By |
|
Date |
04-27-2021 |
Time |
|
Sent To |
|
|
| Notes |
| 2021-04-27 11:34:55 | ZONING COMMENTS - 6910 SOUTH DIXIE HIGHWAY - PALM BEACH | | | OUTPATIENT SURGERY- ISPR 21-01 | | | | | | Z21010014 | 6910 SOUTH DIXIE HIGHWAY | ISPR 21-01 | | | | | | PLEASE NOTE THE FOLLOWING WHEN RESUBMITTING: | | | A. WRITTEN RESPONSES TO COMMENTS MADE BY ALL | | | DEPARTMENTS SHALL BE PROVIDED UPON RESUBMISSION. | | | B. PROVIDE AN ELECTRONIC COPY OF ALL PLANS AND 2 SETS | | | OF PHYSICAL PLANS, ALONG WITH ONE (1) REDUCED COPY (11 | | | IN X 17 IN). | | | C. PLEASE NOTE THAT RE-SUBMITTALS MAY BE SUBJECT TO | | | ADDITIONAL COMMENTS. | | | D. IF NO RESPONSE IS RECEIVED WITHIN 60 DAYS OF THE | | | ISSUANCE OF THESE COMMENTS, THE APPLICATION WILL BE | | | CONSIDERED WITHDRAWN AND ANY FURTHER ACTION WILL | | | REQUIRE SUBMISSION OF A NEW DEVELOPMENT APPLICATION. | | | E. A RESUBMITTAL FEE OF 20% OF THE ORIGINAL APPLICATION | | | FEE WILL BE ASSESSED AFTER THE FIRST | | | RESUBMITTAL. | | | _______________________________________________________ | | | ___________________ | | | APPLICATION SUBMITTAL | | | | | | -PROVIDE TRAFFIC CONCURRENCY LETTER FROM THE COUNTY FOR | | | PROJECT. (AWAITING. THE LETTER SUBMITTED WAS NOT | | | GENERATED FROM THE COUNTY.) | | | | | | -PROVIDE WRITTEN CONFIRMATION FROM UTILITY COMPANIES. | | | (AWAITING) | | | | | | -PROVIDE THE WARRANTY DEED. (SATISFIED) | | | | | | -ON THE COVER SHEET, THE LAND USE DESIGNATION IS | | | INCORRECT. (COMMERCIAL)(SATISFIED) | | | | | | -ALLEY ABANDONMENT PB 1881 IS REQUIRED PRIOR TO SITE | | | PLAN APPROVAL. (AWAITING) | | | | | | SITE PLAN | | | | | | -PROVIDE BICYCLE PARKING WITH CITY APPROVED BICYCLE | | | RACK AND ADD TO INFORMATION TABLE WITH PARKING | | | INFORMATION. (ONE (1) BICYCLE SPACE FOR EVERY | | | 20-AUTOMOBILE SPACE OR A FRACTION OF.) PLEASE SEE THE | | | CITY DETAIL ON BICYCLE RACKS. (SATISFIED) | | | | | | -WILL THE RECONSTRUCTION OF THE PARKING LOT BRING IT | | | INTO COMPLIANCE WITH LANDSCAPE REQUIREMENTS? THE SITE | | | IS OVER-PARKED. (ANSWERED) | | | | | | SUGGESTIONS: LANDSCAPE ISLAND AT SOUTH END OF | | | EASTERN-MOST PARKING ROW. (SATISFIED) | | | | | | REMOVAL OF EXISTING IMPROVEMENTS WITHIN THE VISIBILITY | | | TRIANGLES. THERE ARE STILL SOME PARKING AREAS IN THE | | | SITE VISIBILITY TRIANGLE. (PARTIALLY SATISFIED) | | | | | | -COUNTED 56 PROVIDED PARKING SPACES, CORRECT | | | INFORMATION TABLE. TOTAL PROVIDED 49. (SATISFIED) | | | | | | -PROVIDE THE ADA SPACES PROVIDED IN INFORMATION TABLE. | | | THREE (3) ADA SPACES ARE REQUIRED. (SATISFIED) | | | | | | -PROVIDE AN ENLARGED TYPICAL DETAIL OF DOUBLE-STRIPING | | | OF THE PARKING STALL TO ENSURE CORRECT DIMENSIONS. | | | (SATISFIED) | | | | | | NOTE: THE PLAN INDICATES PARKING STALLS ARE TO HAVE | | | 6-INCH WHITE STALL LINE, CODE REQUIRES 4 INCH DOUBLE | | | STRIPING. (SATISFIED) | | | | | | -CONSIDER ELIMINATING THE WHEEL STOPS FROM PARKING | | | SPACES AND MOVING THE CURB TO PROVIDE 16 FOOT PAVED | | | STALL TO INCREASE IMPERVIOUS AREA. (SATISFIED) | | | | | | -SETBACK ON THE SOUTHSIDE IS 4.6 FEET WHERE 5 FEET IS | | | REQUIRED. CONSIDER RECESSING ADDITION BACK TO MEET THE | | | REQUIRED SETBACK. (SATISFIED) | | | | | | --CORRECT THE CORNER SETBACK ON COVER PAGE. VARIANCE IS | | | NO LONGER NEEDED. (SATISFIED) | | | | | | -WHAT WILL BE THE HOURS OF OPERATION OF THE CLINIC? | | | (SATISFIED) | | | | | | -FIX THE SMALL SECTION OF BRICK ON THE SIDEWALK ON | | | DIXIE HWY. CONSIDER REPAIRING ENTIRELY WITH CONCRETE. | | | (SATISFIED) | | | | | | -GENERATOR AND CHILLER NEED TO BE ENCLOSED WITH FENCE | | | OR WALL AND SHRUBS. (SATISFIED) | | | | | | -PROVIDE A DUMPSTER ENCLOSURE DETAIL. (SATISFIED) | | | | | | -LANDSCAPE ISLANDS ON EITHER SIDE OF THE DUMPSTER | | | ENCLOSURE SHOULD MEET THE MINIMUM WIDTH REQUIREMENTS. | | | (SATISFIED) | | | | | | -LIGHTING NEEDS TO BE SHIELDED TO REDUCE GLARE AND | | | SHALL BE ARRANGED TO REFLECT LIGHT OR GLARE AWAY FROM | | | ALL ADJACENT RESIDENTIAL DISTRICTS, ADJACENT | | | RESIDENCES, OR PUBLIC THOROUGHFARES. LEVELS SHOULD BE | | | LESS THAN 0.5 FOOTCANDLES WHEN MEASURED AT PROPERTY | | | LINE ADJACENT TO RESIDENTIAL. (SATISFIED) | | | | | | ALANA WOOTEN | | | PLANNER | | | PLANNING DIVISION | | | 561-822-1449 | | | [email protected] | | | | | | | | | | | 2021-04-23 13:24:09 | PPRC ZONING COMMENTS - 6910 SOUTH DIXIE HIGHWAY - PALM | | | BEACH OUTPATIENT SURGERY- ISPR 21-01 | | | 3/23/2021 | | | Z21010014 | 6910 SOUTH DIXIE HIGHWAY | ISPR 21-01 | | | | | | PLEASE NOTE THE FOLLOWING WHEN RESUBMITTING: | | | A. WRITTEN RESPONSES TO COMMENTS MADE BY ALL | | | DEPARTMENTS SHALL BE PROVIDED UPON RESUBMISSION. | | | B. PROVIDE AN ELECTRONIC COPY OF ALL PLANS AND 2 SETS | | | OF PHYSICAL PLANS, ALONG WITH ONE (1) REDUCED COPY (11 | | | IN X 17 IN). | | | C. PLEASE NOTE THAT RE-SUBMITTALS MAY BE SUBJECT TO | | | ADDITIONAL COMMENTS. | | | D. IF NO RESPONSE IS RECEIVED WITHIN 60 DAYS OF THE | | | ISSUANCE OF THESE COMMENTS, THE APPLICATION WILL BE | | | CONSIDERED WITHDRAWN AND ANY FURTHER ACTION WILL | | | REQUIRE SUBMISSION OF A NEW DEVELOPMENT APPLICATION. | | | E. A RESUBMITTAL FEE OF 20% OF THE ORIGINAL APPLICATION | | | FEE WILL BE ASSESSED AFTER THE FIRST | | | RESUBMITTAL. | | | _______________________________________________________ | | | ___________________ | | | APPLICATION SUBMITTAL | | | | | | -PROVIDE TRAFFIC CONCURRENCY LETTER FROM THE COUNTY FOR | | | PROJECT. (SATISFIED) | | | | | | -PROVIDE WRITTEN CONFIRMATION FROM UTILITY COMPANIES. | | | (AWAITING) | | | | | | -PROVIDE THE WARRANTY DEED. (SATISFIED) | | | | | | -ON THE COVER SHEET, THE LAND USE DESIGNATION IS | | | INCORRECT. (COMMERCIAL)(SATISFIED) | | | | | | SITE PLAN | | | | | | -PROVIDE BICYCLE PARKING WITH CITY APPROVED BICYCLE | | | RACK AND ADD TO INFORMATION TABLE WITH PARKING | | | INFORMATION. (ONE (1) BICYCLE SPACE FOR EVERY | | | 20-AUTOMOBILE SPACE OR A FRACTION OF.) PLEASE SEE THE | | | CITY DETAIL ON BICYCLE RACKS. (SATISFIED) | | | | | | -WILL THE RECONSTRUCTION OF THE PARKING LOT BRING IT | | | INTO COMPLIANCE WITH LANDSCAPE REQUIREMENTS? THE SITE | | | IS OVER-PARKED. (ANSWERED) | | | | | | SUGGESTIONS: LANDSCAPE ISLAND AT SOUTH END OF | | | EASTERN-MOST PARKING ROW. (SATISFIED) | | | | | | REMOVAL OF EXISTING IMPROVEMENTS WITHIN THE VISIBILITY | | | TRIANGLES. THERE ARE STILL SOME PARKING AREAS IN THE | | | SITE VISIBILITY TRIANGLE. (PARTIALLY SATISFIED) | | | | | | -COUNTED 56 PROVIDED PARKING SPACES, CORRECT | | | INFORMATION TABLE. TOTAL PROVIDED 49. (SATISFIED) | | | | | | -PROVIDE THE ADA SPACES PROVIDED IN INFORMATION TABLE. | | | THREE (3) ADA SPACES ARE REQUIRED. (SATISFIED) | | | | | | -PROVIDE AN ENLARGED TYPICAL DETAIL OF DOUBLE-STRIPING | | | OF THE PARKING STALL TO ENSURE CORRECT DIMENSIONS. | | | (SATISFIED) | | | | | | NOTE: THE PLAN INDICATES PARKING STALLS ARE TO HAVE | | | 6-INCH WHITE STALL LINE, CODE REQUIRES 4 INCH DOUBLE | | | STRIPING. (SATISFIED) | | | | | | -CONSIDER ELIMINATING THE WHEEL STOPS FROM PARKING | | | SPACES AND MOVING THE CURB TO PROVIDE 16 FOOT PAVED | | | STALL TO INCREASE IMPERVIOUS AREA. (SATISFIED) | | | | | | -SETBACK ON THE SOUTHSIDE IS 4.6 FEET WHERE 5 FEET IS | | | REQUIRED. CONSIDER RECESSING ADDITION BACK TO MEET THE | | | REQUIRED SETBACK. (SATISFIED) | | | | | | --CORRECT THE CORNER SETBACK ON COVER PAGE. VARIANCE IS | | | NO LONGER NEEDED. (NEW COMMENT)(SATISFIED) | | | | | | -WHAT WILL BE THE HOURS OF OPERATION OF THE CLINIC? | | | (SATISFIED) | | | | | | -FIX THE SMALL SECTION OF BRICK ON THE SIDEWALK ON | | | DIXIE HWY. CONSIDER REPAIRING ENTIRELY WITH CONCRETE. | | | (SATISFIED) | | | | | | -GENERATOR AND CHILLER NEED TO BE ENCLOSED WITH FENCE | | | OR WALL AND SHRUBS. (SATISFIED) | | | | | | -PROVIDE A DUMPSTER ENCLOSURE DETAIL. (SATISFIED) | | | | | | -LANDSCAPE ISLANDS ON EITHER SIDE OF THE DUMPSTER | | | ENCLOSURE SHOULD MEET THE MINIMUM WIDTH REQUIREMENTS. | | | (SATISFIED) | | | | | | -LIGHTING NEEDS TO BE SHIELDED TO REDUCE GLARE AND | | | SHALL BE ARRANGED TO REFLECT LIGHT OR GLARE AWAY FROM | | | ALL ADJACENT RESIDENTIAL DISTRICTS, ADJACENT | | | RESIDENCES, OR PUBLIC THOROUGHFARES. LEVELS SHOULD BE | | | LESS THAN 0.5 FOOTCANDLES WHEN MEASURED AT PROPERTY | | | LINE ADJACENT TO RESIDENTIAL. (SATISFIED) | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
03-23-2021 |
|
|
Cont ID |
|
| Sent By |
|
Date |
03-23-2021 |
Time |
|
Rev Time |
0.00 |
| Received By |
|
Date |
03-23-2021 |
Time |
|
Sent To |
|
|
| Notes |
| 2021-03-23 10:05:46 | PPRC ZONING COMMENTS - 6910 SOUTH DIXIE HIGHWAY - PALM | | | BEACH OUTPATIENT SURGERY- ISPR 21-01 | | | 3/23/2021 | | | Z21010014 | 6910 SOUTH DIXIE HIGHWAY | ISPR 21-01 | | | | | | PLEASE NOTE THE FOLLOWING WHEN RESUBMITTING: | | | A. WRITTEN RESPONSES TO COMMENTS MADE BY ALL | | | DEPARTMENTS SHALL BE PROVIDED UPON RESUBMISSION. | | | B. PROVIDE AN ELECTRONIC COPY OF ALL PLANS AND 2 SETS | | | OF PHYSICAL PLANS, ALONG WITH ONE (1) REDUCED COPY (11 | | | IN X 17 IN). | | | C. PLEASE NOTE THAT RE-SUBMITTALS MAY BE SUBJECT TO | | | ADDITIONAL COMMENTS. | | | D. IF NO RESPONSE IS RECEIVED WITHIN 60 DAYS OF THE | | | ISSUANCE OF THESE COMMENTS, THE APPLICATION WILL BE | | | CONSIDERED WITHDRAWN AND ANY FURTHER ACTION WILL | | | REQUIRE SUBMISSION OF A NEW DEVELOPMENT APPLICATION. | | | E. A RESUBMITTAL FEE OF 20% OF THE ORIGINAL APPLICATION | | | FEE WILL BE ASSESSED AFTER THE FIRST | | | RESUBMITTAL. | | | _______________________________________________________ | | | ___________________ | | | APPLICATION SUBMITTAL | | | | | | -PROVIDE TRAFFIC CONCURRENCY LETTER FROM THE COUNTY FOR | | | PROJECT. (AWAITING) | | | | | | -PROVIDE WRITTEN CONFIRMATION FROM UTILITY COMPANIES. | | | (AWAITING) | | | | | | -PROVIDE THE WARRANTY DEED. (SATISFIED) | | | | | | -ON THE COVER SHEET, THE LAND USE DESIGNATION IS | | | INCORRECT. (COMMERCIAL)(SATISFIED) | | | | | | SITE PLAN | | | | | | -PROVIDE BICYCLE PARKING WITH CITY APPROVED BICYCLE | | | RACK AND ADD TO INFORMATION TABLE WITH PARKING | | | INFORMATION. (ONE (1) BICYCLE SPACE FOR EVERY | | | 20-AUTOMOBILE SPACE OR A FRACTION OF.) PLEASE SEE THE | | | CITY DETAIL ON BICYCLE RACKS. (SATISFIED) | | | | | | -WILL THE RECONSTRUCTION OF THE PARKING LOT BRING IT | | | INTO COMPLIANCE WITH LANDSCAPE REQUIREMENTS? THE SITE | | | IS OVER-PARKED. (ANSWERED) | | | | | | SUGGESTIONS: LANDSCAPE ISLAND AT SOUTH END OF | | | EASTERN-MOST PARKING ROW. (SATISFIED) | | | | | | REMOVAL OF EXISTING IMPROVEMENTS WITHIN THE VISIBILITY | | | TRIANGLES. THERE ARE STILL SOME PARKING AREAS IN THE | | | SITE VISIBILITY TRIANGLE. (PARTIALLY SATISFIED) | | | | | | -COUNTED 56 PROVIDED PARKING SPACES, CORRECT | | | INFORMATION TABLE. TOTAL PROVIDED 49. (SATISFIED) | | | | | | -PROVIDE THE ADA SPACES PROVIDED IN INFORMATION TABLE. | | | THREE (3) ADA SPACES ARE REQUIRED. (SATISFIED) | | | | | | -PROVIDE AN ENLARGED TYPICAL DETAIL OF DOUBLE-STRIPING | | | OF THE PARKING STALL TO ENSURE CORRECT DIMENSIONS. | | | (SATISFIED) | | | | | | NOTE: THE PLAN INDICATES PARKING STALLS ARE TO HAVE | | | 6-INCH WHITE STALL LINE, CODE REQUIRES 4 INCH DOUBLE | | | STRIPING. (SATISFIED) | | | | | | -CONSIDER ELIMINATING THE WHEEL STOPS FROM PARKING | | | SPACES AND MOVING THE CURB TO PROVIDE 16 FOOT PAVED | | | STALL TO INCREASE IMPERVIOUS AREA. (SATISFIED) | | | | | | -SETBACK ON THE SOUTHSIDE IS 4.6 FEET WHERE 5 FEET IS | | | REQUIRED. CONSIDER RECESSING ADDITION BACK TO MEET THE | | | REQUIRED SETBACK. (SATISFIED) | | | | | | --CORRECT THE CORNER SETBACK ON COVER PAGE. VARIANCE IS | | | NOT LONGER NEEDED. (NEW COMMENT) | | | | | | -WHAT WILL BE THE HOURS OF OPERATION OF THE CLINIC? | | | (SATISFIED) | | | | | | -FIX THE SMALL SECTION OF BRICK ON THE SIDEWALK ON | | | DIXIE HWY. CONSIDER REPAIRING ENTIRELY WITH CONCRETE. | | | (SATISFIED) | | | | | | -GENERATOR AND CHILLER NEED TO BE ENCLOSED WITH FENCE | | | OR WALL AND SHRUBS. (SATISFIED) | | | | | | -PROVIDE A DUMPSTER ENCLOSURE DETAIL. (SATISFIED) | | | | | | -LANDSCAPE ISLANDS ON EITHER SIDE OF THE DUMPSTER | | | ENCLOSURE SHOULD MEET THE MINIMUM WIDTH REQUIREMENTS. | | | (SATISFIED) | | | | | | -LIGHTING NEEDS TO BE SHIELDED TO REDUCE GLARE AND | | | SHALL BE ARRANGED TO REFLECT LIGHT OR GLARE AWAY FROM | | | ALL ADJACENT RESIDENTIAL DISTRICTS, ADJACENT | | | RESIDENCES, OR PUBLIC THOROUGHFARES. LEVELS SHOULD BE | | | LESS THAN 0.5 FOOTCANDLES WHEN MEASURED AT PROPERTY | | | LINE ADJACENT TO RESIDENTIAL. (SATISFIED) | | | | | | | | | | | | | | | ALANA WOOTEN | | | PLANNER | | | PLANNING DIVISION | | | 561-822-1449 | | | [email protected] | | | | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
02-09-2021 |
|
|
Cont ID |
|
| Sent By |
|
Date |
02-09-2021 |
Time |
|
Rev Time |
|
| Received By |
|
Date |
02-09-2021 |
Time |
|
Sent To |
|
|
| Notes |
| 2021-02-09 10:24:36 | PPRC ZONING COMMENTS - 6910 SOUTH DIXIE HIGHWAY - PALM | | | BEACH OUTPATIENT SURGERY- ISPR 21-01 | | | 2/9/2021 | | | Z21010014 | 6910 SOUTH DIXIE HIGHWAY | ISPR 21-01 | | | | | | PLEASE NOTE THE FOLLOWING WHEN RESUBMITTING: | | | A. WRITTEN RESPONSES TO COMMENTS MADE BY ALL | | | DEPARTMENTS SHALL BE PROVIDED UPON RESUBMISSION. | | | B. PROVIDE AN ELECTRONIC COPY OF ALL PLANS AND 2 SETS | | | OF PHYSICAL PLANS, ALONG WITH ONE (1) REDUCED COPY (11 | | | IN X 17 IN). | | | C. PLEASE NOTE THAT RE-SUBMITTALS MAY BE SUBJECT TO | | | ADDITIONAL COMMENTS. | | | D. IF NO RESPONSE IS RECEIVED WITHIN 60 DAYS OF THE | | | ISSUANCE OF THESE COMMENTS, THE APPLICATION WILL BE | | | CONSIDERED WITHDRAWN AND ANY FURTHER ACTION WILL | | | REQUIRE SUBMISSION OF A NEW DEVELOPMENT APPLICATION. | | | E. A RESUBMITTAL FEE OF 20% OF THE ORIGINAL APPLICATION | | | FEE WILL BE ASSESSED AFTER THE FIRST | | | RESUBMITTAL. | | | _______________________________________________________ | | | ___________________ | | | APPLICATION SUBMITTAL | | | | | | -PROVIDE TRAFFIC CONCURRENCY LETTER FROM THE COUNTY FOR | | | PROJECT. | | | | | | -PROVIDE WRITTEN CONFIRMATION FROM UTILITY COMPANIES. | | | | | | -PROVIDE THE WARRANTY DEED. | | | | | | -ON THE COVER SHEET, THE LAND USE DESIGNATION IS | | | INCORRECT. (COMMERCIAL) | | | | | | SITE PLAN | | | | | | -PROVIDE BICYCLE PARKING WITH CITY APPROVED BICYCLE | | | RACK AND ADD TO INFORMATION TABLE WITH PARKING | | | INFORMATION. (ONE (1) BICYCLE SPACE FOR EVERY | | | 20-AUTOMOBILE SPACE OR A FRACTION OF.) PLEASE SEE THE | | | CITY DETAIL ON BICYCLE RACKS. | | | | | | -WILL THE RECONSTRUCTION OF THE PARKING LOT BRING IT | | | INTO COMPLIANCE WITH LANDSCAPE REQUIREMENTS? THE SITE | | | IS OVER-PARKED. | | | | | | SUGGESTIONS: LANDSCAPE ISLAND AT SOUTH END OF | | | EASTERN-MOST PARKING ROW. | | | | | | REMOVAL OF EXISTING IMPROVEMENTS WITHIN THE VISIBILITY | | | TRIANGLES. | | | | | | -COUNTED 56 PROVIDED PARKING SPACES, CORRECT | | | INFORMATION TABLE. | | | | | | -PROVIDE THE ADA SPACES PROVIDED IN INFORMATION TABLE. | | | THREE (3) ADA SPACES ARE REQUIRED. | | | | | | -PROVIDE AN ENLARGED TYPICAL DETAIL OF DOUBLE-STRIPING | | | OF THE PARKING STALL TO ENSURE CORRECT DIMENSIONS. | | | | | | NOTE: THE PLAN INDICATES PARKING STALLS ARE TO HAVE | | | 6-INCH WHITE STALL LINE, CODE REQUIRES 4 INCH DOUBLE | | | STRIPING. | | | | | | -CONSIDER ELIMINATING THE WHEEL STOPS FROM PARKING | | | SPACES AND MOVING THE CURB TO PROVIDE 16 FOOT PAVED | | | STALL TO INCREASE IMPERVIOUS AREA. | | | | | | -SETBACK ON THE SOUTHSIDE IS 4.6 FEET WHERE 5 FEET IS | | | REQUIRED. CONSIDER RECESSING ADDITION BACK TO MEET THE | | | REQUIRED SETBACK. | | | | | | -WHAT WILL BE THE HOURS OF OPERATION OF THE CLINIC? | | | | | | -FIX THE SMALL SECTION OF BRICK ON THE SIDEWALK ON | | | DIXIE HWY. CONSIDER REPAIRING ENTIRELY WITH CONCRETE. | | | | | | -GENERATOR AND CHILLER NEED TO BE ENCLOSED WITH FENCE | | | OR WALL AND SHRUBS. | | | | | | -PROVIDE A DUMPSTER ENCLOSURE DETAIL. | | | | | | -LANDSCAPE ISLANDS ON EITHER SIDE OF THE DUMPSTER | | | ENCLOSURE SHOULD MEET THE MINIMUM WIDTH REQUIREMENTS. | | | | | | -LIGHTING NEEDS TO BE SHIELDED TO REDUCE GLARE AND | | | SHALL BE ARRANGED TO REFLECT LIGHT OR GLARE AWAY FROM | | | ALL ADJACENT RESIDENTIAL DISTRICTS, ADJACENT | | | RESIDENCES, OR PUBLIC THOROUGHFARES. LEVELS SHOULD BE | | | LESS THAN 0.5 FOOTCANDLES WHEN MEASURED AT PROPERTY | | | LINE ADJACENT TO RESIDENTIAL. | | | | | | | | | ALANA WOOTEN | | | PLANNER | | | PLANNING DIVISION | | | 561-822-1449 | | | [email protected] | | | | | | |
|
|
| |
Print |
|
Account Summary | Usage Policy | Privacy Policy