Plan Review Details - Project Z20120016
| Plan Review Stops For Project Z20120016 |
| Review Stop |
AIPP |
ART IN PUBLIC PLACES |
| Rev No |
1 |
Status |
P |
Date |
05-12-2021 |
|
|
Cont ID |
|
| Sent By |
scwelter |
Date |
01-11-2021 |
Time |
10:24 |
Rev Time |
0.00 |
| Received By |
rrossano |
Date |
05-12-2021 |
Time |
10:20 |
Sent To |
|
|
| Notes |
| 2021-05-12 10:19:56 | THE PUBLIC ART PASS IS CONTINGENT ON THE FOLLOWING: | | | AT THE TIME OF BUILDING PERMIT SUBMITTAL, A COMPLETED | | | PUBLIC ART ASSESSMENT APPLICATION, EVIDENCE OF ESCROW | | | FOR THE 1%, BUDGET OF THE PROPOSED CONCEPT ALONG WITH | | | OTHER ARTWORKS OR BALANCE AS A DEPOSIT TO THE CITY MUST | | | BE COMPLETED. | | | PLEASE SUBMIT THE ABOVE TO [email protected], AND COPY | | | [email protected], [email protected] AND [email protected] WHEN | | | SUBMITTING FOR BUILDING PERMIT. | | | PROPOSED ART CONCEPT OF THE ARTIST WORK FOR THE GARAGE | | | WAS PRESENTED TO THE ARTLIFE COMMITTEE AS A CONCEPT AND | | | NON-ACTION ITEM ON MAY 5, 2021. | | | DEVELOPER MUST STILL PROVIDE BUDGET BREAKDOWN OF THE 1% | | | INCLUDING VALUE OF PROPOSED CONCEPT, MATERIALS, | | | MAINTENANCE PLAN ADDRESSING FLORIDA?S CLIMATE AND | | | STREET NAMES (INTERSECTIONS) OF THE VARIOUS VANTAGE | | | POINTS. | | | | | 2021-01-11 11:01:02 | PROPOSED ARTWORK IS TEMPORARY IN NATURE. | | | MATERIAL HAS A SHORT LIFE SPAN IN SOUTH FLORIDA WEATHER | | | (HEAT, HUMIDITY, SALT, AND RAIN) | | | PROPOSED WORK WILL REQUIRE IN FIVE YEARS A COMPLETE | | | RE-APPLICATION MAKING THIS A HIGH MAINTENANCE PROJECT | | | DOES NOT COMPLY WITH VISUAL ACCESSIBILITY AS THE ARTIST | | | HAS STATED THAT THERE ARE SPECIFIC VANTAGE POINTS TO | | | ?SEE? THE ARTWORK | | | HAVING ONLY TWO VANTAGE POINTS TO VIEW THAT WORK POSES | | | A SAFETY HAZARD INCLUDING ADA COMPLIANCE | | | THE VALUE OF THE WORK IS UNDER THE 1% | | | THE WORK IS NOT APPROPRIATE FOR THE SITE IN DESIGN, | | | SCALE AND MATERIALS. | | | DISTINCT ARTWORK SECTION 78-129 (B)(D): ARTWORK FOR | | | COMPLIANCE WITH THE PUBLIC ART ASSESSMENT WILL NOT BE | | | CONSIDERED AS COMPLIANT WITH ANY REQUIREMENTS OF THE | | | ZONING AND LAND DEVELOPMENT REGULATIONS. ANY | | | REQUIREMENTS FOR THE PARKING GARAGE MAY NOT BE | | | CONSIDERED AS PART OF THE PUBLIC ART REQUIREMENT. | | | I RECOMMENDED IN MY 10.27.2020 EMAIL TO JON SCHMIDT | | | THAT THE PASEO BE CONSIDERED FOR THE LOCATION OF | | | MULTIPLE ARTWORKS. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
01-07-2021 |
|
|
Cont ID |
|
| Sent By |
rrossano |
Date |
01-13-2021 |
Time |
10:21 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
01-13-2021 |
Time |
19:06 |
Sent To |
|
|
| Notes |
| 2021-01-13 19:36:46 | DEVELOPMENT SERVICES DEPARTMENT, BUILDING DIVISION, | | | COMMENTS: | | | | | | 1. THIS REVIEW IS A CURSORY REVIEW AS IT RELATES TO THE | | | SITE. IT IS NOT A REVIEW FOR FULL COMPLIANCE WITH | | | FLORIDA BUILDING CODE. THE FOLLOWING COMMENTS ARE TO BE | | | ADDRESSED FOR THE BUILDING PERMIT APPLICATION. | | | | | | 2. NUMBER OF ACCESSIBLE PARKING SPACES. THE DATA TABLE | | | ON SITE PLAN, SHEET A-100, AND PRJECT DATA PLAN SHEET | | | A001, STATES THAT 1200 PARKING SPACES PROVIDED. THE | | | NUMBER OF ACCSEEIBLE PARKING SPACES SHALL BE BASED ON | | | THE NUMBER OF PARKING SPACES PROVIDED SO 24 ACCESSIBLE | | | PARKING SPACES ARE REQUIRED. THE MINIMUM NUMBER OF | | | ACCESSIBLE PARKING SPACES PROVIDED SHALL BE IN | | | ACCORDANCE WITH SECTION 208.2 OF FLORIDA ACCESSIBILITY | | | CODE. | | | | | | 3. VAN ACCESSIBLE PARKING SPACES. THE PLANS DO NOT | | | LABEL ANY OF THE ACCESSIBLE PARKING SPACES AS VAN | | | ACCESIBLE. 4 VAN ACCESSIBLE PARKING SPACES ARE | | | REQUIRED. PER SECTION 208.2.4 OF FLORIDA ACCESSIBILITY | | | CODE, ONE IN EVERY SIX REQUIRED ACCESSIBLE SPACES (AT | | | LEAST ONE) IN A PARKING STRUCTURE, SHALL BE ?VAN | | | ACCESSIBLE? AND DESIGNED IN ACCORDANCE WITH SECTION OF | | | 502 OF FLORIDA ACCESSIBILITY CODE (VERTICAL CLEARANCE | | | NOT LESS THAN 98 INCHES AT SPACE AND VEHICULAR ACCESS | | | ROUTE) | | | | | | 4. BUILDING SIZE. WHEN SUBMITTED FOR BUILDING PERMIT, | | | THE PLANS SHALL SHOW THAT THE TYPE OF CONSTRUCTION FOR | | | THE BUILDINGS WILL BE IN ACCORDANCE WITH THE HEIGHT, | | | AREA AND OCCUPANCY LIMITATIONS IN CHAPTER 5 OF THE | | | FLORIDA BUILDING CODE. | | | | | | 5. ENCLOSED PARKING GARAGES. IF THE PARKING GARAGE DOES | | | NOT HAVE WALL OPENINGS, OR SUFFICIENT WALL OPENINGS TO | | | MEET THE DEFINITION OF AN OPEN PARKING GARAGE, IT WILL | | | BE CONSIDERED AN ENCLOSED PARKING GARAGE AND MUST HAVE | | | EXHAUST SYSTEMS. THE EXHAUST SYSTEMS SHALL BE DESIGNED | | | TO MINIMIZE NOISE LEVELS USING INLINE FAN SILENCERS OR | | | OTHER APPROVED METHODS. | | | | | | 6. PARKING STRUCTURE ROOF ACCESS. SHEET A111 DOE NOT | | | CLEARLY SHOW/LABEL WHAT IS ON THE PARKING STRUCTURE | | | ROOF. IS THERE ANY PROPOSED BUILDING OCCUPANT ACCESS TO | | | THE PARKING STRUCTURE ROOF? IF SO, PLEASE PROVIDE THE | | | OCCUPANT COUNT. | | | | | | 7. GREASE INTERCEPTOR. GREASE INTERCEPTORS MAY BE | | | REQUIRED IF ANY OF THE RETAIL SPACES MIGHT BE | | | RESTAURANTS. FOR INFORMATION ON THE REQUIRED TYPE, SIZE | | | AND LOCATION, PLEASE CONTACT TIM LARGE, CHIEF PLUMBING | | | INSPECTOR, DEVELOPMENT SERVICES DEPARTMENT, AT (561) | | | 805-6692, OR BY EMAIL: [email protected] | | | | | | 8. SEPARATE PERMITS REQUIRED. ALL APPLICABLE PERMITS | | | AND SUB-PERMITS MUST BE OBTAINED BEFORE COMMENCING THE | | | WORK. SEPARATE PERMITS, PLANS AND FEES, ARE REQUIRED | | | FOR SIGNS, SWIMMING POOLS AND SPAS, GAS SYSTEMS, | | | GENERATORS, FIRE ALARM SYSTEMS, FIRE SPRINKLER AND | | | OTHER FIRE SUPPRESSION SYSTEMS, GREASE INTERCEPTORS, | | | SITE LIGHTING, SITE LANDSCAPE, SITE IRRIGATION, ETC. | | | | | | 9. CONTRACTOR VEHICLE PARKING. PROPERTY OWNER AND | | | CONTRACTOR SHALL MAKE ARRANGEMENTS FOR PARKING OF | | | CONTRACTOR VEHICLES TO MINIMIZE THE IMPACT ON ALL | | | NEIGHBORING PROPERTIES. | | | | | | 10. PROTECTION OF NEIGHBORING PROPERTY. PROPERTY OWNER | | | AND CONTRACTOR SHALL PROTECT ALL NEIGHBORING PROPERTY, | | | INCLUDING VEHICLES, FROM DAMAGE OR DIRT CAUSED BY THE | | | CONSTRUCTION, AND SHALL NOTIFY THE OCCUPANTS OF | | | NEIGHBORING PROPERTIES ABOUT ALL STAGES OF CONSTRUCTION | | | THAT MAY AFFECT THE USE OF THEIR PROPERTY. | | | | | | 11. BUILDING ADDRESS. EACH SEPARATE BUILDING, AND UNIT | | | WITH AN INDEPENDENT ENTRANCE FROM THE STREET, SHALL | | | HAVE A SEPARATE ADDRESS ASSIGNED BASED ON THE LOCATION | | | OF THE BUILDING ENTRANCE. FOR STREET ADDRESSING, | | | CONTACT CAROLINE PUELL, ADDRESSING COORDINATOR, AT | | | (561) 805 6659, OR BY EMAIL: [email protected] | | | | | | 12. ART IN PUBLIC PLACES. THIS PROJECT WILL BE SUBJECT | | | TO ART IN PUBLIC PLACES (AIPP) ASSESSMENT. FOR ADVICE | | | ON THE PROVISION OF PUBLIC ARTWORK IN LIEU OF THE AIPP | | | ASSESSMENT, CONTACT SYBILLE WELTER, ART IN PUBLIC | | | PLACES COORDINATOR, AT (561) 822-1521, OR BY EMAIL: | | | [email protected] | | | | | | ROBERT BROWN | | | BUILDING OFFICIAL | | | TEL: 561 805 6652 | | | EMAIL: [email protected] | | | |
|
|
| Review Stop |
ENG - PPRC |
ENGINEERING - PPRC |
| Rev No |
4 |
Status |
F |
Date |
12-23-2021 |
|
|
Cont ID |
|
| Sent By |
rrossano |
Date |
12-23-2021 |
Time |
|
Rev Time |
0.00 |
| Received By |
rrossano |
Date |
12-23-2021 |
Time |
|
Sent To |
|
|
| Notes |
| 2021-12-23 10:16:23 | NO COMMENTS FROM RICK ROSSANO, PROJECT COORDINATOR, | | | ENG. SERVICES DEPT., 561-494-1098 [email protected] : | | | | | | COMMENTS FROM MARK HURLEY, FIELD CUSTOMER SERVICE | | | SUPER., WPB PUBLIC UTILITIES, 561-494-2262 OR | | | [email protected]: | | | | | | -COULD NOT FIND RESPONSE LETTER IN RESUBMITTAL PACKAGE. | | | DID NOT HAVE RESPONSE BACK FROM LAST REVIEW COMMENTS: | | | PLEASE VERIFY ROOT BARRIERS ARE NOT NEEDED FOR THE CITY | | | PARKS METERED WATER SERVICE NEAR THE NORTHWEST AREA OF | | | PROPERTY; | | | WATER DEMAND CALCULATIONS HAD FOOD OPERATIONS ITEM AND | | | SEE CAFE ON PLANS, BUT DID NOT SEE ANY GREASE TRAPS. | | | ARE ANY NEEDED?; | | | THE EXIT DRIVEWAY CURBING NEAR THE NORTH PROPERTY LINE | | | ON THE CIVIL PLANS DOES NOT MATCH THE SITE PLANS OR | | | LANDSCAPING PLANS. PLEASE MAKE SURE ALL PLAN SETS | | | MATCH. IF CIVIL PLANS ARE ALTERED, SEE IF ANY CONFLICTS | | | ARISE WITH THE VEHICLE CIRCULATION PLANS. | | | | | | -AREA OF DETECTABLE TACTILE PADS NEAR DRIVEWAYS DOES | | | NOT MATCH BETWEEN ALL PLAN SETS. PLEASE UPDATE ALL PLAN | | | SETS SO THAT THEY MATCH. | | | | | | -ARE THE PEDESTRIAN REFUGES LEVEL WITH THE DRIVEWAYS | | | WITHOUT RAISED ELEVATIONS? | | | | | | -ON THE CIVIL PLANS A COUPLE OF THE SOUTHERN BIKE RACKS | | | APPEAR TO BE CONFLICTING WITH TREE TRUNKS BUT THEY LOOK | | | ON THE LANDSCAPING PLANS. PLEASE UPDATE AS NEEDED. | | | | | | COMMENTS FROM MICHAEL TECHNOW, PROJECT ENGINEER, WPB | | | PUBLIC UTILITIES, 561-494-1047, [email protected] : | | | | | | -NO 3? SERVICE. USE 1? OR 4?. | | | -NEED PROFILE OF WATER MAIN TIE IN SHOWING EXISTING | | | UTILITIES AND CONFLICTS. | | | -ADD NOTE THAT THIS IS IN LIFT STATION #40. | | | -PROPOSED 8? PVC SANITARY IS TOO CLOSE TO THE FPL DUCT | | | BANK. | | | -WHEN 8? SANITARY LINE IS USED INSTALL A MANHOLE | | | INSTEAD OF CLEAN OUT OR USE AN 8? CLEAN OUT. | | | -IF NO EASEMENT IS PROVIDED THAN THE CLEAN OUT NEEDS TO | | | BE IN THE RIGHT OF WAY. | | | -SHOW PROFILE OF 8? CONNECTIONS WITH CONFLICTS AND | | | CROSSINGS. | | | -USE FDOT RESTORATION DETAIL. | | | -MANHOLES NEED TO BE LEGIBLE ON DIXIE. | | | -ADD NOTE TO LINE EXISTING GRAVITY SEWER AS THEY WILL | | | BE CUTTING INTO IT. | | | -SHOW EXISTING LATERALS ON GRAVITY MAIN. SHOW EXISTING | | | WATER SERVICES. | | | -PROVIDE POST CCTV OF PROPOSED LATERALS. | | | -WHY PARKS AND REC REFERENCE? | | | -ONCE SOFT DIGS AND POTHOLE REPORT HAS BEEN SUBMITTED | | | WE WILL REASSESS. | | | -?INSET A? IS UNDER REVIEW. WHY FIVE TAPS? WHY NOT | | | GROUP AND SPLIT? | | | | | | COMMENTS FROM TRACY WARD, SR. STORMWATER ENG., CITY OF | | | WPB ENG. SERVICES, [email protected], 561-494-1120: | | | | | | THE STREETS SURROUNDING THE DEVELOPMENT ARE MAINTAINED | | | BY FDOT. FDOT WILL NEED TO APPROVE THE PROPOSED | | | LANDSCAPING AND BIKE RACKS IN THE RIGHTS-OF-WAY AS WELL | | | AS THE SIDEWALK AREAS SLOPING TOWARD THE RIGHTS-OF-WAY. | | | | | | THE PROPOSED 18? PIPE LEAVING STRUCTURE OCS-2 CONNECTS | | | TO A DRAINAGE STRUCTURE WITH ONLY 15? DIAMETER PIPE | | | LEAVING THE STRUCTURE. | | | | | | | | | FEEL FREE TO CONTACT US IF YOU HAVE ANY QUESTIONS OR | | | CONCERNS, THANKS. | | | | | | |
|
|
| Review Stop |
ENG - PPRC |
ENGINEERING - PPRC |
| Rev No |
3 |
Status |
F |
Date |
06-15-2021 |
|
|
Cont ID |
|
| Sent By |
rrossano |
Date |
06-15-2021 |
Time |
|
Rev Time |
0.00 |
| Received By |
rrossano |
Date |
06-15-2021 |
Time |
|
Sent To |
|
|
| Notes |
| 2021-06-15 07:02:05 | 1. PLEASE SHOW PAVEMENT RESTORATION AT SCALE FOR CITY | | | MAINTAINED ROADWAYS PER CITY OF WPB STANDARD DETAIL | | | GC-8. | | | 2. PLEASE CONFIRM ALL STANDARD DETAILS ARE CURRENT | | | VERSIONS. LATEST CAD VERSIONS CAN BE OBTAINED FROM | | | JANICE TARBILL AT [email protected] | | | 3. PLEASE PROVIDE UPDATE ON STATUS OF REQUESTED CCTV. | | | | | | FEEL FREE TO CONTACT US IF YOU HAVE ANY QUESTIONS OR | | | CONCERNS, THANKS. | | | RICK ROSSANO, PROJECT COORDINATOR, ENGINEERING SERVICES | | | DEPARTMENT, (561) 494-1098 [email protected] | | | | | | THE FOLLOWING COMMENTS ARE FROM MARK HURLEY, FIELD | | | CUSTOMER SERVICE SUPERVISOR, WPB PUBLIC UTILITIES, | | | PLEASE CONTACT 561-494-2262 OR [email protected]: | | | -PLEASE VERIFY ROOT BARRIERS ARE NOT NEEDED FOR THE | | | CITY PARKS METERED WATER SERVICE NEAR THE NORTHWEST | | | AREA OF PROPERTY. | | | | | | -WATER DEMAND CALCULATIONS HAD FOOD OPERATIONS ITEM AND | | | SEE CAFE ON PLANS, BUT DID NOT SEE ANY GREASE TRAPS. | | | ARE ANY NEEDED? | | | | | | -THE EXIT DRIVEWAY CURBING NEAR THE NORTH PROPERTY LINE | | | ON THE CIVIL PLANS DOES NOT MATCH THE SITE PLANS OR | | | LANDSCAPING PLANS. PLEASE MAKE SURE ALL PLAN SETS | | | MATCH. IF CIVIL PLANS ARE ALTERED, SEE IF ANY CONFLICTS | | | ARISE WITH THE VEHICLE CIRCULATION PLANS. | | | |
|
|
| Review Stop |
ENG - PPRC |
ENGINEERING - PPRC |
| Rev No |
2 |
Status |
F |
Date |
04-22-2021 |
|
|
Cont ID |
|
| Sent By |
rrossano |
Date |
04-22-2021 |
Time |
|
Rev Time |
0.00 |
| Received By |
rrossano |
Date |
04-22-2021 |
Time |
|
Sent To |
|
|
| Notes |
| 2021-04-22 11:27:02 | THE FOLLOWING COMMENTS ARE FROM MARK HURLEY, FIELD | | | CUSTOMER SERVICE SUPERVISOR, WPB PUBLIC UTILITIES, | | | PLEASE CONTACT 561-494-2262 OR [email protected]: | | | | | | -PLEASE ADD NOTE OR LABEL TO UTILITY PLAN INCORPORATING | | | RESPONSE TO PRIOR COMMENT ABOUT BUILDING STRUCTURES | | | ENCROACHING ON EXISTING UTILITY EASEMENTS. | | | | | | -PLEASE ADD MORE DESCRIPTION TO LABEL OF 6 INCH METER | | | ON INSET A OF UTILITY PLAN DESCRIBING WHAT THE WATER | | | METER IS FEEDING, SIMILAR TO THE 3 INCH METER. | | | | | | -SHOW AND LABEL DRAINAGE FOR FIREROOM ON INSET A OF | | | UTILITY PLAN. | | | | | | -THE BYPASSES FOR THE LARGE WATER METERS MAY NOT BE | | | SHOWN TO SCALE ON UTILITY PLAN AND MAY EXTEND CLOSER TO | | | THE BOLLARDS. | | | | | | -FURTHER FEEDBACK/DIRECTION ON THE WATER MAIN WORK MAY | | | BE PROVIDED AT FORMAL ENGINEERING SUBMITTAL. | | | | | | -PAVEMENT RESTORATION BOUNDARIES APPEAR SMALLER THAN | | | REQUIRED BY STANDARDS. PLEASE SHOW THE ADDITIONAL | | | PAVEMENT RESTORATION BOUNDARIES FOR THE SEWER WORK IN | | | THE STREETS AND MAKE SURE BOUNDARIES COMPLY WITH | | | STANDARDS. | | | | | | -WPB GIS AND ASBUILT SHOW EXISTING 8 INCH SEWER LATERAL | | | AT EAST SIDE OF PROPERTY NEAR PROPOSED 6 INCH C900. | | | PLEASE CONFIRM IF STILL THERE AND SHOW AND LABEL AS | | | NEEDED. | | | | | | -TRAFFIC ARROWS ARE MISSING FOR SOUTHERN DRIVEWAY ON | | | UTILITY PLAN. PLEASE ADD. | | | | | | -CONFIRM THAT THE PROPOSED 8 INCH SEWER LATERALS MAY | | | HAVE 6 INCH CLEANOUTS. | | | | | | -VERIFY FIRE HYDRANTS HAVE THE NECESSARY CLEARANCE | | | DISTANCES REQUIRED BY STANDARD DETAIL P-8. | | | | | | -FIRE HYDRANTS APPEAR TO BE HALF IN PLANTERS AND HALF | | | IN SIDEWALKS. CAN PLANTERS BE EXTENDED SLIGHTLY AT | | | THOSE AREAS SO THAT THE FIRE HYDRANTS ARE COMPLETELY IN | | | THE PLANTER? | | | | | | -THE PROXIMITY OF SOME OF THE WATER UTILITIES TO TREES | | | IS STILL CONCERNING. PLEASE ENSURE BOTH IRRIGATION | | | METERS AND FIRE HYDRANTS HAVE ADEQUATE CLEARANCE | | | DISTANCE. IF ROOT BARRIERS ARE BEING UTILIZED, PLEASE | | | SHOW THOSE ON LANDSCAPE PLAN. | | | | | | -PARKS EXISTING METERED IRRIGATION SERVICE CURRENTLY | | | HAS 2 INCH METER. RELOCATED WATER SERVICE ONLY SHOWS 1 | | | INCH METER. PLEASE CONFIRM THAT WPB PARKS APPROVED THE | | | SIZE REDUCTION. ALSO ENSURE THAT A BACKFLOW CAGE IS | | | INSTALLED IF REQUIRED BY PARKS. | | | | | | -PLEASE SHOW AND DESCRIBE HOW WPB UTILITY WORKERS WILL | | | ACCESS THE WATER METERS THAT ARE ON THE FIRELINE | | | BACKFLOW ASSEMBLIES IN THE FIREROOM. | | | | | | -PROPERTY OWNER WILL BE REQUIRED TO SUBMIT AND RECORD | | | BACKFLOW COVENANT. CONTACT [email protected] FOR TEMPLATE | | | AND DIRECTION. | | | | | | -CHECK SOUTHERN-MOST FLAG POLE ON WEST SIDE OF PROPERTY | | | TO SEE IF IT CONFLICTS WITH DRAINAGE UTILITY. | | | | | | FEEL FREE TO CONTACT US IF YOU HAVE ANY QUESTIONS OR | | | CONCERNS, THANKS. | | | RICK ROSSANO, PROJECT COORDINATOR, ENGINEERING SERVICES | | | DEPARTMENT, (561) 494-1098 [email protected] | | | |
|
|
| Review Stop |
ENG - PPRC |
ENGINEERING - PPRC |
| Rev No |
1 |
Status |
F |
Date |
01-07-2021 |
|
|
Cont ID |
|
| Sent By |
rrossano |
Date |
01-07-2021 |
Time |
|
Rev Time |
|
| Received By |
rrossano |
Date |
01-07-2021 |
Time |
|
Sent To |
|
|
| Notes |
| 2021-01-07 10:23:13 | 1. THE CITY OF WEST PALM BEACH HAS A NUMBER OF | | | REGULATIONS AND PERMIT REQUIREMENTS WHICH DIRECTLY | | | AFFECT THE DEVELOPMENT AND INSTALLATION OF WATER AND | | | WASTEWATER UTILITIES WITHIN THE CITY. TO VIEW | | | DEVELOPMENT PERMIT SUBMITTAL REQUIREMENTS AND OTHER | | | ENGINEERING RELATED DOCUMENTS, OPEN A BROWSER IN CHROME | | | AND GO TO: WWW.WPB.ORG/ENGDOCS . TO LOGIN, UNDER | | | ?EMAIL? ENTER [email protected] ; UNDER ?PASSWORD? ENTER | | | SIMPLE321# | | | THERE ARE 4 PAGES OF AVAILABLE ENGINEERING DOCUMENTS | | | FOR YOUR USE. | | | 2. CODE OF ORDINANCES, CITY OF WEST PALM BEACH, | | | FLORIDA, CODIFIED THROUGH ORD. NO. 4183-08, ADOPTED | | | SEPT. 22, 2008. (SUPPLEMENT NO. 18) CHAPTER 90 | | | UTILITIES, ARTICLE I. SEC. 90-7. | | | POLICY REGARDING EXTENSION OF WATER OR SEWER SERVICE | | | FACILITIES OF THE CITY: | | | THE WATER AND WASTEWATER SERVICE AGREEMENTS AND THE | | | CONSTRUCTION PERMITS ADDRESS RESERVATION OF CAPACITY | | | BASED ON USAGE, METER SIZE AND FEES, DESIGN STANDARDS, | | | BACKFLOW PREVENTION, FIRE SERVICE AND IRRIGATION. | | | 3. AS OF DECEMBER 20, 2015, THE CITY OF WEST PALM BEACH | | | CROSS-CONNECTION CONTROL MANUAL HAS BEEN REVISED, | | | STATING "ALL BACKFLOW DEVICES MUST BE LEAD-FREE". FOR | | | MORE INFORMATION, OPEN A BROWSER IN CHROME AND GO TO: | | | WWW.WPB.ORG/ENGDOCS .TO LOGIN, UNDER ?EMAIL? ENTER | | | [email protected] ; UNDER ?PASSWORD? ENTER SIMPLE321# | | | CROSS-CONNECTION CONTROL MANUAL IS ON PAGE 4. | | | 4. PLEASE SUBMIT A FORMAL AS-BUILT REQUEST FOR ALL CITY | | | OF WEST PALM BEACH-OWNED UTILITIES WITHIN THE PUBLIC | | | RIGHT OF WAY FOR THE ENTIRE EXTENT OF THE LIMITS OF | | | YOUR PROJECT. IDENTIFY TYPE OF UTILITY, LOCATION, PIPE | | | MATERIAL, AGE AND SIZE. PLEASE CONTACT JANICE TARBILL | | | IN THE WPB ENGINEERING SERVICES DEPARTMENT AT | | | [email protected] OR 561-494-1040 FOR FURTHER | | | ASSISTANCE. | | | 5. PLANS SHALL SHOW PROPOSED LOCATIONS AND DIMENSIONS | | | OF ALL WATER, STORMWATER, AND SANITARY AND SEWER LINES, | | | INCLUDING STUBS TO EACH PROPERTY LINE FOR WATER AND | | | SANITARY SEWERS, THE MAKE AND MODEL OF ALL VALVES, | | | METERS, AND OTHERS DEVICES TO BE INSTALLED ON THE | | | SYSTEM, CATCH BASINS, CULVERTS, DITCHES INCLUDING | | | GRADES, PIPES SIZES, MATERIALS, ELEVATIONS, | | | ASSUMPTIONS, CALCULATIONS, INVERT ELEVATIONS FOR ALL | | | INLETS AND MANHOLES AND PROFILES OF SANITARY SEWER | | | LINES. ALL AVAILABLE ELEVATION SHALL BE SHOWN ON THE | | | PROFILE VIEW. DIRECTION OF FLOW SHALL BE SHOWN ON PLAN | | | VIEW ON PLAN VIEW FOR ALL SANITARY AND STORM SEWERS. | | | PLEASE SHOW SLOPE % ON ALL SANITARY LINES AND CALL OUT | | | MATERIAL. ADDITIONALLY, PLAN VIEW SHALL SHOW ALL | | | EXISTING AND PROPOSED UNDERGROUND UTILITY LAYOUT, | | | INCLUDING FIBER OPTIC, ELECTRIC, GAS, AND CABLEVISION & | | | TELECOMMUNICATION FACILITIES LOCATED ON THE | | | RIGHT-OF-WAY. PROVIDE PROFILE AND CLEARANCES AT ALL | | | UTILITY CROSSINGS. | | | 6. CUT AND CAP UTILITIES NOT IN USE, AND REMOVE ANY | | | ABANDONED UTILITY LINES LARGER THAN 2 INCHES FROM CITY | | | ROW. | | | 7. PLEASE SUBMIT COMPLETED LOS ANALYSIS SUMMARY TABLE | | | DIRECTLY TO ENGINEERING (SHEET 33 OF CITY OF WPB | | | DEVELOPMENT APPLICATION). | | | 8. PROVIDE CALCULATIONS ON PLANS OF EXISTING AND | | | PROPOSED DEMANDS FOR WATER & SEWER (AVERAGE, MAXIMUM | | | AND PEAK) AND FIRE FLOW DEMANDS. CALCULATIONS SHALL BE | | | PER FAC 64E-6 FOR SEWER AND PER FAC 64-E.008 FOR WATER. | | | 9. SHOW VERTICAL DATUM AND DATUM CONVERSION INFORMATION | | | (NAVD 88 AND NGVD 29). | | | 10. PROVIDE CCTV VIDEO OF EXISTING SANITARY SEWER AND | | | STORMWATER ALONG ENTIRE PROJECT FRONTAGE. | | | 11. PLEASE PROVIDE CALCULATIONS OF REVISED PERVIOUS AND | | | IMPERVIOUS CALCULATIONS FOR THE PROPOSED IMPACTED | | | AREAS. | | | 12. PROVIDE ONSITE CLEANOUTS NEAR PROPERTY LINE FOR | | | PROPOSED SANITARY LATERALS. | | | 13. PLEASE LABEL WATER LINES AS PRIVATE WHERE | | | APPLICABLE. | | | 14. PLEASE PROVIDE ENLARGED VIEW ON PLANS OF PROPOSED | | | LOCATION OF WATER METER AND BACKFLOW PREVENTION. | | | 15. COORDINATE WITH MARK HURLEY, FIELD CUSTOMER SERVICE | | | SUPERVISOR WITH CITY OF WPB PUBLIC UTILITIES, REGARDING | | | PLACEMENT OF BACKFLOW DEVICES AND WATER METERS. CONTACT | | | HIM AT 561-494-2262 OR [email protected] | | | 16. PROVIDE DEDICATED UTILITY EASEMENTS TO ALLOW ACCESS | | | FOR CITY PERSONNEL TO PROPOSED UTILITY WATER METERS. | | | | | | FEEL FREE TO CONTACT US IF YOU HAVE ANY QUESTIONS OR | | | CONCERNS, THANKS. RICK ROSSANO, PROJECT COORDINATOR, | | | ENGINEERING SERVICES DEPARTMENT, (561) 494-1098 | | | [email protected] | | | | | | THE FOLLOWING COMMENTS ARE FROM MARK HURLEY, FIELD | | | CUSTOMER SERVICE SUPERVISOR, WPB PUBLIC UTILITIES, | | | PLEASE CONTACT 561-494-2262 OR [email protected]: | | | | | | -BUILDING STRUCTURES SHOULD NOT ENCROACH ON UTILITY | | | EASEMENTS. | | | | | | -WEST SIDE OF BUILDING LOOKS LIKE IT MAY EXTEND INTO | | | R/W. VERIFY IF THAT IS ACCEPTABLE. | | | | | | -EXISTING FIRE HYDRANT AT SOUTHEAST AREA OF PROPERTY | | | NEED UTILITY EASEMENT. | | | | | | -VERIFY IF THE 14FOOT UTILITY EASEMENT ON NORTH SIDE OF | | | THE PROPERTY IS EXTENDING DOWN MIDWAY ON THE EAST AND | | | WEST SIDES OF THE PROPERTY. IF SO, PLEASE LABEL MORE | | | CLEARLY ON UTILITY PLAN. | | | | | | -ENSURE THAT WATER METERS ARE OUT OF HEAVY PEDESTRIAN | | | TRAFFIC. | | | | | | -THE 3INCH AND 6INCH METERS NEED TO BE ABOVE-GROUND | | | INSTALLATION USING STANDARD DETAIL WS-3. | | | | | | -VERIFY THAT WATER SERVICES DO NOT HAVE TREE CONFLICTS | | | WITH ROOTS. LANDSCAPING PLAN SHOWS MANY TREES NEAR THE | | | WATER SERVICES. IF CONFLICT INCREASE CLEARANCE DISTANCE | | | AND ADD ROOT BARRIERS. | | | | | | -CAN THE WATER SERVICES BE DESIGNED SO THAT THE | | | PLUMBING DOES NOT CROSS? | | | | | | -LANDSCAPING PLAN DOES NOT SHOW THE ABOVE-GROUND | | | BACKFLOW ASSEMBLIES. PLEASE ADD ICONS FOR THE BACKFLOW | | | ASSEMBLIES TO LANDSCAPING PLAN. | | | | | | -INSET A ON UTILITY PLAN HAS A VERTICAL DASHED LINE. | | | HAVING TROUBLE FIGURING OUT WHAT IT IS ? PLEASE LABEL | | | IT. | | | | | | -CONSIDER DUAL/PARALLEL BACKFLOW ASSEMBLIES FOR THE | | | LARGE METERS SO THAT WATER OUTAGES ARE MINIMIZED DURING | | | BACKFLOW MAINTENANCE. | | | | | | -SOME DISTANCES FROM THE WATER METERS TO THE BACKFLOW | | | ASSEMBLIES ARE EXCESSIVE. TRY TO REDUCE THOSE | | | DISTANCES. | | | | | | -PLEASE ADD VISUAL MEASUREMENT ICON TO THE SCALE FOR | | | INSET A ON UTILITY PLAN. | | | | | | -PLANS DO NOT SHOW PAVEMENT RESTORATION ON OKEECHOBEE | | | OR QUADRILLE FOR THE UTILITY WORK BEING COMPLETED IN | | | THE ROADWAY. | | | | | | -FOR THE FORMAL ENGINEERING SUBMITTAL, PLEASE ADD THE | | | FOLLOWING TO THE UTILITY PLAN: WATER DEMAND | | | CALCULATIONS, ADDRESS, AND STANDARD DETAIL COPIES (ON | | | SEPARATE PAGE). | | | | | | -A WATER SERVICE ON WEST SIDE OF PROPERTY IS PROPOSED | | | TO BE REMOVED, BUT IT IS A CITY PARKS WATER SERVICE. | | | APPROVAL WOULD BE NEEDED FROM CITY PARKS DEPARTMENT AND | | | THEY MAY REQUIRE IT TO BE RELOCATED. | | | | | | -CANNOT FIND AN FDC SHOWING ON THE UTILITY PLAN FOR THE | | | FIRE SYSTEM. IS ONE NEEDED? | | | | | | | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
06-22-2021 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
06-22-2021 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
06-22-2021 |
Time |
11:49 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
05-06-2021 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
05-06-2021 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
05-06-2021 |
Time |
13:39 |
Sent To |
|
|
| Notes |
| 2021-05-06 13:40:08 | FIRE HAS NO OBJECTIONS TO THE PROPOSED AND APPROVES. | | | | | | FIRE'S APPROVAL OF THIS SUBMITTED PROJECT DOES NOT | | | CONSTITUTE IT'S FINAL REVIEW OR APPROVAL. | | | | | | FIRE SHALL REVIEW ALL SUBMITTED BUILDING PLANS AT THE | | | APPROPRIATE TIME AND IN ACCORDANCE WITH THE | | | REQUIREMENTS OF ALL APPLICABLE CODES AND STANDARDS. | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
01-06-2021 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
01-06-2021 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
01-06-2021 |
Time |
14:19 |
Sent To |
|
|
| Notes |
| 2021-01-06 15:07:38 | THE FOLLOWING COMMENTS WERE SUBMITTED BY PETER LEDUC, | | | FIRE MARSHAL, BUREAU OF FIRE PREVENTION, WEST PALM | | | BEACH FIRE RESCUE. | | | | | | THIS REVIEW CAN ONLY BE CONSIDERED PRELIMINARY AS THE | | | DRAWINGS THAT WERE REVIEWED WERE NOT COMPLETE. | | | ADDITIONAL COMMENTS CAN BE EXPECTED WHEN FULL DRAWINGS | | | ARE SUBMITTED FOR PERMIT. | | | | | | THE FIRE PREVENTION BUREAU HAS NO OBJECTIONS TO THE | | | PROPOSED PROJECT. | | | | | | 1. CONSTRUCTION, DEMOLITION, AND RENOVATION TO COMPLY | | | WITH NFPA 241. EXTRA ATTENTION SHALL BE GIVEN TO THE | | | PERMITTING AND LOCATION OF CONSTRUCTION TRAILERS. A | | | PERMIT IS REQUIRED FOR ANY CONSTRUCTION TRAILER RELATED | | | TO THIS PROJECT. SEPARATION DISTANCES FROM MAIN | | | STRUCTURES AS WELL AS OTHER TRAILERS SHALL BE CLOSELY | | | MONITORED FOR THE REQUIREMENTS OF FIRE SPRINKLER | | | PROTECTION. | | | | | | 2. SITE ACCESS AND EXIT POINTS ARE TO BE CLEARLY | | | IDENTIFIED AND MAINTAINED FOR EMERGENCY VEHICLES DURING | | | ALL CONSTRUCTION ACTIVITIES. | | | | | | 3. THE BUILDING ADDRESS SHALL BE CLEARLY VISIBLE FROM | | | ALL ACCESS ROADWAYS, INCLUDING DURING CONSTRUCTION. | | | ADDRESS NUMBERS SHALL CONTRAST WITH THEIR BACKGROUND | | | AND SHALL NOT BE LESS THAN SIX (6) INCHES IN HEIGHT | | | WITH A ONE (1) INCH STROKE FOR ALL BUILDINGS. | | | | | | 4. DURING CONSTRUCTION, TRASH AND DEBRIS IS TO BE | | | REMOVED FROM THE SITE DAILY OR MORE OFTEN TO REDUCE THE | | | ACCUMULATION OF POTENTIAL LIFE AND FIRE SAFETY HAZARDS. | | | | | | 5. THE CONSTRUCTION OF THE BUILDING SHALL COMPLY WITH | | | THE CURRENT EDITION OF THE FLORIDA FIRE PREVENTION | | | CODE, INCLUDING NFPA 1 & 101, AND ALL ASSOCIATED FIRE | | | CODES. | | | | | | 6. ALL PARKING STRUCTURES SHALL COMPLY WITH NFPA 88A, | | | PARKING STRUCTURES AND NFPA 101, THE LIFE SAFETY CODE, | | | INCLUDING MORE SPECIFICALLY, CHAPTER 42 STORAGE | | | OCCUPANCIES (PARKING STRUCTURES) | | | | | | 7. A NFPA 13 COMPLAINT FIRE SPRINKLER SYSTEM AND NFPA | | | 14 COMPLIANT WET STANDPIPE SYSTEM ARE REQUIRED FOR THIS | | | STRUCTURE. TEMPORARY STANDPIPES ARE REQUIRED WHEN THE | | | BUILDING REACHES THREE LEVELS OR THIRTY FEET WHILE | | | BEING CONSTRUCTED. | | | | | | SEPARATE SHOP DRAWINGS, ARE REQUIRED TO BE SUBMITTED, | | | REVIEWED AND APPROVED BY THE FIRE PREVENTION BUREAU | | | PRIOR TO ANY INSTALLATION. | | | | | | IT IS RECOMMENDED FOR HIGH RISES TO HAVE TWO SEPARATE | | | FDC LOCATIONS REMOTELY LOCATED WITH 100 FT OF FIRE | | | HYDRANT. CONSIDER ONE ON OKEECHOBEE NEAR S DIXIE AND | | | ANOTHER ON LAKEVIEW NEAR QUADRILLE AVE. | | | | | | 7A. PER NFPA 14 | | | 6.4.5.4* FIRE DEPARTMENT CONNECTIONS SHALL BE LOCATED | | | NOT MORE THAN 100 FT (30.5 M) FROM THE NEAREST FIRE | | | HYDRANT CONNECTED TO AN APPROVED WATER SUPPLY. | | | | | | 7B. PLEASE REVIEW THE DISTANCE SEPARATION OF THE | | | STAIRWELLS AS THE SEPARATION DISTANCE IS NOT INDICATED. | | | 7.3.2.2* WHERE THE MOST REMOTE PORTION OF A | | | NON-SPRINKLERED FLOOR OR STORY IS LOCATED IN EXCESS OF | | | 150 FT (45.7 M) OF TRAVEL DISTANCE FROM A HOSE | | | CONNECTION IN OR ADJACENT TO A REQUIRED EXIT OR THE | | | MOST REMOTE PORTION OF A SPRINKLERED FLOOR OR STORY | | | IS LOCATED IN EXCESS OF 200 FT (61 M) OF TRAVEL | | | DISTANCE FROM A HOSE CONNECTION IN OR ADJACENT TO A | | | REQUIRED EXIT, ADDITIONAL HOSE CONNECTIONS SHALL BE | | | PROVIDED, IN APPROVED LOCATIONS, WHERE REQUIRED BY THE | | | LOCAL FIRE DEPARTMENT OR THE AHJ. | | | | | | 7C. PER NFPA 1 | | | 18.3 WATER SUPPLIES. | | | 18.3.1* AN APPROVED WATER SUPPLY CAPABLE OF SUPPLYING | | | THE REQUIRED FIRE FLOW FOR FIRE PROTECTION SHALL BE | | | PROVIDED TO ALL PREMISES UPON WHICH FACILITIES, | | | BUILDINGS, OR PORTIONS OF BUILDINGS ARE HEREAFTER | | | CONSTRUCTED OR MOVED INTO THE JURISDICTION. THE | | | APPROVED WATER SUPPLY SHALL BE IN ACCORDANCE WITH | | | SECTION 18.4. | | | PER FLORIDA ADMINISTRATIVE CODE SECTION 61G15-32.004, | | | FIRE PROTECTION ENGINEERING DOCUMENTS SHALL INCLUDE THE | | | POINT OF SERVICE FOR THE WATER SUPPLY, A LIST OF | | | APPLICABLE NFPA STANDARDS APPLICABLE TO THE PROJECT, | | | CLASSIFICATION OF HAZARD OCCUPANCY FOR EACH ROOM OR | | | AREA, SUPPRESSION SYSTEM TYPE, DESIGN DENSITIES, WATER | | | SUPPLY DATA (FIRE PUMP DATA, HYDRANT FLOW TEST DATA) | | | AND ANY PERFORMANCE BASED INFORMATION SUCH AS | | | PRE-ENGINEERED SYSTEMS. | | | FOR THE PROPOSED FIRE PUMP(S) , WHAT IS(ARE) THE | | | PRIMARY AND SECONDARY POWER SOURCES? | | | | | | 7D. THE LOCATION OF THE DDCV FIRE LINE LOCATION SHALL | | | MEET THE REQUIREMENTS OF NFPA 24 AND SHALL BE | | | COORDINATED WITH THE OFFICE OF FIRE MARSHAL, THE CITY'S | | | ENGINEERS OFFICE, THE LANDSCAPE PLANNER, AND THE CITY'S | | | PLANNING AND ZONING OFFICE. | | | | | | | | | 8. A CLASS ?A? NFPA 72 COMPLIANT MONITORED FIRE ALARM | | | SYSTEM IS REQUIRED FOR THIS STRUCTURE. SEPARATE SHOP | | | DRAWINGS, ARE REQUIRED TO BE SUBMITTED, REVIEWED AND | | | APPROVED BY THE FIRE PREVENTION BUREAU PRIOR TO ANY | | | INSTALLATION. | | | | | | 9. ALL ELEVATORS SHALL BE EQUIPPED WITH A REGION 7 | | | KEYWAY SYSTEM. | | | | | | ALL NEW ELEVATORS SHALL CONFORM TO THE FIRE FIGHTER?S | | | EMERGENCY OPERATIONS REQUIREMENTS OF ASME A17.1/CSA | | | B44, SAFETY CODE FOR ELEVATORS. | | | | | | ANY BUILDING THAT IS MORE THAN THREE STORIES HIGH OR IN | | | WHICH THE VERTICAL DISTANCE BETWEEN THE BOTTOM TERMINAL | | | LANDING AND THE TOP TERMINAL LANDING EXCEEDS 25 FEET | | | MUST BE CONSTRUCTED TO CONTAIN AT LEAST ONE PASSENGER | | | ELEVATOR THAT IS OPERATIONAL AND WILL ACCOMMODATE AN | | | AMBULANCE STRETCHER 76 INCHES LONG AND 24 INCHES WIDE | | | IN THE HORIZONTAL POSITION. | | | | | | 10. COMPLETE LIFE SAFETY PLANS FOR EACH OCCUPANCY SHALL | | | BE PROVIDED THAT ILLUSTRATE OCCUPANT LOADS, TRAVEL | | | DISTANCES, COMMON PATHS OF TRAVEL, DEAD-END CORRIDORS, | | | EXIT SIGNS, EMERGENCY LIGHTING, EXITS LEADING TO A | | | PUBLIC WAY, FIRE EXTINGUISHER LOCATIONS, AND ALL FIRE | | | SAFETY FEATURES AND EQUIPMENT. | | | | | | 11. ALL EXISTING AND NEW FIRE HYDRANTS PLANNED FOR THIS | | | DEVELOPMENT SHALL BE CLEARLY INDICATED AND IDENTIFIED | | | ON THE PLAN AND CLOSELY COORDINATED WITH THE BUREAU OF | | | FIRE PREVENTION. | | | | | | ALL NEW FIRE HYDRANTS AND FDC?S PLANNED FOR THIS | | | DEVELOPMENT SHALL BE CLOSELY COORDINATED WITH THE | | | BUREAU OF FIRE PREVENTION. PROPOSED FIRE HYDRANTS AND | | | FDC?S SHOULD BE LOCATED ON THE SAME SIDE OF THE STREET | | | OR ACCESS ROADWAY TO ALLOW FREE ACCESS FOR OTHER | | | ARRIVING EMERGENCY VEHICLES. | | | | | | 12. COMMAND ROOM - THERE WAS NO CLEAR INDICATION OF THE | | | LOCATION OF THE EMERGENCY COMMAND CENTER. | | | | | | THE EMERGENCY COMMAND CENTER SHALL COMPLY WITH NFPA 1, | | | CHAPTER 11, BUILDING SERVICES; 11.9 AND SHALL CONTAIN | | | THE FOLLOWING FEATURES: | | | | | | 11.9.1 THE LOCATION, DESIGN, CONTENT, AND FIRE | | | DEPARTMENT ACCESS OF THE EMERGENCY COMMAND CENTER SHALL | | | BE APPROVED BY THE FIRE DEPARTMENT. | | | | | | IT SHALL BE LOCATED WITH AN EXTERIOR DOOR ACCESS AND IN | | | CLOSE RELATION TO THE LOBBY WITH ACCESS. | | | | | | 11.9.2 THE EMERGENCY COMMAND CENTER SHALL BE SEPARATED | | | FROM THE REMAINDER OF THE BUILDING BY A FIRE BARRIER | | | HAVING A FIRE RESISTANCE RATING OF NOT LESS THAN 1 | | | HOUR. | | | | | | 11.9.3 THE EMERGENCY COMMAND CENTER ROOM SHALL BE A | | | MINIMUM OF 96 FT2 (8.9 M2) WITH A MINIMUM DIMENSION OF | | | 8 FT (2.4 M). | | | | | | A.HOWEVER, PER FL BLDG CODE;(MORE STRICT) IT SHALL BE A | | | MINIMUM OF 200 FT SQUARED WITH A MINIMUM DIMENSION OF | | | 10 FT. | | | B. THE FIRE DEPARTMENT COMMUNICATIONS SYSTEM. | | | C. A TELEPHONE FOR FIRE DEPARTMENT USE WITH CONTROLLED | | | ACCESS TO THE PUBLIC TELEPHONE SYSTEM | | | D. SCHEMATIC BUILDING PLANS INDICATING THE TYPICAL | | | FLOOR PLAN AND DETAILING THE BUILDING CORE, MEANS OF | | | EGRESS, FIRE PROTECTION SYSTEMS, FIRE-FIGHTING | | | EQUIPMENT AND FIRE DEPARTMENT ACCESS AND THE LOCATION | | | OF FIRE WALLS, FIRE BARRIERS, FIRE PARTITIONS, SMOKE | | | BARRIERS AND SMOKE PARTITIONS | | | E. A WORK TABLE. | | | F. IF APPLICABLE, A HAZARDOUS MATERIAL MANAGEMENT PLAN | | | FOR THE BUILDING. | | | G. THE EMERGENCY VOICE/ALARM COMMUNICATION SYSTEM | | | CONTROL UNIT. | | | H. ANNUNCIATOR UNIT VISUALLY INDICATING THE LOCATION OF | | | THE ELEVATORS AND WHETHER THEY ARE OPERATIONAL | | | I. STATUS INDICATORS AND CONTROLS FOR AIR DISTRIBUTION | | | SYSTEMS. | | | J. CONTROLS FOR UNLOCKING STAIRWAY DOORS SIMULTANEOUSLY | | | K. SPRINKLER VALVE AND WATER FLOW DETECTOR DISPLAY | | | PANELS | | | L. EMERGENCY AND STANDBY POWER STATUS INDICATORS | | | M. FIRE PUMP STATUS INDICATORS | | | N. GENERATOR SUPERVISION DEVICES AND MANUAL START AND | | | TRANSFER FEATURES. | | | O. PUBLIC ADDRESS SYSTEM, WHERE SPECIFICALLY REQUIRED | | | BY OTHER SECTIONS OF THIS CODE | | | P. CONTROLS REQUIRED FOR SMOKE CONTROL | | | Q. ELEVATOR FIRE RECALL SWITCH IN ACCORDANCE WITH ASME | | | A17.1. | | | R. ELEVATOR EMERGENCY OR STANDBY POWER SELECTOR | | | SWITCH(ES), WHERE EMERGENCY OR STANDBY POWER IS | | | PROVIDED | | | | | | PER NFPA 101, CH 11 | | | | | | 11.8.6* EMERGENCY COMMAND CENTER. | | | | | | 11.8.6.1 AN EMERGENCY COMMAND CENTER SHALL BE PROVIDED | | | IN A | | | LOCATION APPROVED BY THE FIRE DEPARTMENT. | | | 11.8.6.2 THE EMERGENCY COMMAND CENTER SHALL CONTAIN THE | | | FOLLOWING: | | | (1) VOICE FIRE ALARM SYSTEM PANELS AND CONTROLS | | | (2) FIRE DEPARTMENT TWO-WAY TELEPHONE COMMUNICATION | | | SERVICE | | | PANELS AND CONTROLS WHERE REQUIRED BY ANOTHER SECTION | | | OF THIS | | | CODE | | | (3) FIRE DETECTION AND FIRE ALARM SYSTEM ANNUNCIATION | | | PANELS | | | (4) ELEVATOR FLOOR LOCATION AND OPERATION ANNUNCIATORS | | | (5) ELEVATOR FIRE RECALL SWITCH IN ACCORDANCE WITH ASME | | | A17.1/CSA B44, SAFETY CODE FOR ELEVATORS AND ESCALATORS | | | (6) ELEVATOR EMERGENCY POWER SELECTOR SWITCH(ES) WHERE | | | PROVIDED | | | IN ACCORDANCE WITH ASME A17.1/CSA B44 | | | (7) SPRINKLER VALVE AND WATERFLOW ANNUNCIATORS | | | (8) EMERGENCY GENERATOR STATUS INDICATORS | | | (9) CONTROLS FOR ANY AUTOMATIC STAIRWAY DOOR UNLOCKING | | | SYSTEM | | | (10) FIRE PUMP STATUS INDICATORS | | | (11) TELEPHONE FOR FIRE DEPARTMENT USE WITH CONTROLLED | | | ACCESS TO THE | | | PUBLIC TELEPHONE SYSTEM | | | (12) STAIRWAY VIDEO MONITORING EQUIPMENT AS REQUIRED BY | | | 11.8.8 | | | | | | 13. RADIO | | | | | | NFPA 1, CHAPTER 11, BUILDING SERVICES; 11.10 TWO-WAY | | | RADIO ENHANCEMENT SERVICES. | | | 11.10.1 IN ALL NEW AND EXISTING BUILDINGS, MINIMUM | | | RADIO SIGNAL STRENGTH FOR FIRE DEPARTMENT | | | COMMUNICATIONS SHALL BE MAINTAINED AT A LEVEL | | | DETERMINED BY THE AHJ. | | | | | | NFPA 72, 24.5.2* TWO-WAY RADIO COMMUNICATIONS | | | ENHANCEMENT SYSTEMS. | | | 24.5.2.2 RADIO COVERAGE. RADIO COVERAGE SHALL BE | | | PROVIDED THROUGHOUT THE BUILDING AS A PERCENTAGE OF | | | FLOOR AREA AS SPECIFIED IN 24.5.2.2.1 THROUGH | | | 24.5.2.2.3. | | | 24.5.2.2.1 CRITICAL AREAS. CRITICAL AREAS, SUCH AS THE | | | EMERGENCY COMMAND CENTER(S), THE FIRE PUMP ROOM(S), | | | EXIT STAIRS, EXIT PASSAGEWAYS, ELEVATOR LOBBIES, | | | STANDPIPE CABINETS, SPRINKLER SECTIONAL VALVE | | | LOCATIONS, AND OTHER AREAS DEEMED CRITICAL BY THE | | | AUTHORITY HAVING JURISDICTION, SHALL BE PROVIDED WITH | | | 99 PERCENT FLOOR AREA RADIO COVERAGE. | | | 24.5.2.2.2 GENERAL BUILDING AREAS. GENERAL BUILDING | | | AREAS SHALL BE PROVIDED WITH 90 PERCENT FLOOR AREA | | | RADIO COVERAGE. | | | 24.5.2.3 SIGNAL STRENGTH. | | | 24.5.2.3.1 INBOUND. A MINIMUM INBOUND SIGNAL STRENGTH | | | OF -95 DBM, OR OTHER SIGNAL STRENGTH AS REQUIRED BY THE | | | AUTHORITY HAVING JURISDICTION, SHALL BE PROVIDED | | | THROUGHOUT THE COVERAGE AREA. | | | 24.5.2.3.2 OUTBOUND. A MINIMUM OUTBOUND SIGNAL STRENGTH | | | OF -95 DBM AT THE DONOR SITE, OR OTHER SIGNAL STRENGTH | | | AS REQUIRED BY THE AUTHORITY HAVING JURISDICTION, SHALL | | | BE PROVIDED FROM THE COVERAGE AREA. | | | | | | THE SYSTEM SHALL MAINTAIN A MINIMUM RADIO SIGNAL | | | STRENGTH OF -95 DBM FOR THE RADIO SYSTEM USED BY WEST | | | PALM BEACH FIRE RESCUE. TESTING SHALL BE BY AN | | | ACCEPTABLE NATIONAL STANDARD DOCUMENTING PERCENTAGES | | | NOTED ABOVE AND BY ACTUAL RADIO TESTING BY FIRE | | | PERSONNEL. IF THE MINIMUM CANNOT BE MAINTAINED, A | | | BI-DIRECTIONAL AMPLIFIED SYSTEM SHALL BE INSTALLED WITH | | | A MINIMUM 2-HOUR RUN TIME BATTERY BACK-UP. | | | PLEASE CONTACT MARK FILLA, PALM BEACH COUNTY PUBLIC | | | SAFETY RADIO SYSTEMS MANAGER, AS OUR RADIOS OPERATE ON | | | THEIR SYSTEM FOR DETAILED RADIO FREQUENCY AND | | | INSTALLATION INSTRUCTIONS. | | | | | | | | | 14. KNOX-BOX KEY SYSTEM SHALL BE REQUIRED FOR THIS | | | BUILDING. DUE TO SIZE AND ACCESS POINTS MULTIPLE KNOX | | | BOXES MAY BE REQUIRED. | | | | | | PLEASE COORDINATE WITH THE OFFICE OF THE FIRE MARSHAL. | | | | | | ANY GATES SHALL BE PROVIDED WITH KNOX KEY ACCESS LOCKS, | | | PADLOCKS AND/OR SWITCHES FOR 24 HOUR EMERGENCY ACCESS. | | | | | | 15. THE SMOKE CONTROL SYSTEM SHALL COMPLY WITH NFPA | | | 101, CHAPTER 9, BUILDING SERVICE AND FIRE PROTECTION | | | EQUIPMENT, INCLUDING: | | | | | | THE SMOKE CONTROL SYSTEMS SHALL BE INSTALLED, | | | INSPECTED, TESTED, AND MAINTAINED IN ACCORDANCE WITH | | | NFPA 92, STANDARD FOR SMOKE CONTROL SYSTEMS; NFPA 204, | | | STANDARD FOR SMOKE AND HEAT VENTING; OR NATIONALLY | | | RECOGNIZED STANDARDS, ENGINEERING GUIDES, OR | | | RECOMMENDED PRACTICES, AS APPROVED BY THE AUTHORITY | | | HAVING JURISDICTION. | | | | | | THE ENGINEER OF RECORD SHALL CLEARLY IDENTIFY THE | | | INTENT OF THE SYSTEM, THE DESIGN METHOD USED, THE | | | APPROPRIATENESS OF THE METHOD USED, AND THE REQUIRED | | | MEANS OF INSPECTING, TESTING, AND MAINTAINING THE | | | SYSTEM. | | | ACCEPTANCE TESTING SHALL BE PERFORMED BY A SPECIAL | | | INSPECTOR IN ACCORDANCE WITH SECTION 9.9. | | | | | | 16. THE BUREAU'S APPROVAL OF THIS SUBMITTED PROJECT | | | DOES NOT CONSTITUTE IT'S FINAL REVIEW OR APPROVAL. | | | | | | 17. THE BUREAU SHALL REVIEW ALL SUBMITTED BUILDING | | | PLANS AT THE APPROPRIATE TIME AND IN ACCORDANCE WITH | | | THE REQUIREMENTS OF ALL APPLICABLE CODES AND STANDARDS. | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
6 |
Status |
P |
Date |
02-28-2023 |
|
|
Cont ID |
|
| Sent By |
rcaranci |
Date |
02-28-2023 |
Time |
14:06 |
Rev Time |
0.00 |
| Received By |
rcaranci |
Date |
02-28-2023 |
Time |
14:06 |
Sent To |
|
|
| Notes |
| 2023-02-28 14:07:36 | FROM: RAY CARANCI, SENIOR LANDSCAPE PLANNER | | | 561-822-1462 | | | PROJECT: WEST PALM POINT Z20120016 | | | FEBRUARY 28, 2023 | | | I HAVE REVIEWED THE ABOVE REFERENCED PETITION, AND | | | PROVIDE THE FOLLOWING COMMENTS FOR THE FINAL SITE PLAN | | | APPROVAL: | | | | | | | | | 1. SATISFIED. LIST THE TREE SPECIES AND SQUARE FOOTAGE | | | CREDIT FOR THE OPEN SPACE SQUARE FOOTAGE CALCULATIONS | | | FOR EACH OPEN SPACE. PERCENTAGES DO NOT MEET THE | | | REQUIREMENTS FOR THE ENTIRE PRIVATE OPEN SPACE SO AN | | | AREA MEETING THE REQUIREMENTS NEEDS TO BE DESIGNATED. | | | OS-1 OPEN SPACE PLAN DOES NOT MATCH THE LANDSCAPE PLAN | | | SHEET LP-1 FOR THE NUMBER OF CLUSIA TREES AT THE | | | NORTHEAST CORNER OF THE PLAZA. | | | NEEDS TO BE BASED ON PROVIDED. DESIGNATE AN AREA THAT | | | MEETS THE MINIMUM OPEN SPACE AREA REQUIRED AND THEN | | | PROVIDE PERCENTAGES OF VEGETATED AREA AND TREE CANOPY | | | FOR THAT AREA. 17,895 SQ FT REQUIRES 4,473.75 SQ FT | | | VEGETATED AREA AND 5,368.5 SQ FT TREE CANOPY, WHICH ARE | | | NOT MET. | | | THE PUBLIC OPEN SPACE PLAZA NEEDS TO MEET THE CRITERIA | | | ABOVE. THE PRIVATE OPEN SPACE ROOFTOP GARDEN HAS SOME | | | TREE CANOPY SQUARE FOOTAGE CALCULATIONS THAT ARE OFF | | | AND LIGUSTRUMS ARE NOT COUNTED. | | | 10/31/22: THE AREA DESIGNATED AS PUBLIC OPEN SPACE HAS | | | CHANGED FROM THE APPROVAL. MAKE THE FOLLOWING | | | CORRECTIONS TO THE PLAN: | | | ??? THE AREA CANNOT HAVE THE SMALL PIECE SPLIT OFF FOR | | | THE PASEO, AS IT WOULD HAVE TO MEET THE OPEN SPACE | | | REQUIREMENTS ON ITS OWN IF SEPARATED. IF CHANGING THE | | | DESIGNATED AREA, SHOW ALL THE REQUIREMENTS ARE MET FOR | | | THE NEW AREA. | | | ??? ADDITIONAL TREES PROVIDED FOR THE CONDITION FOR THE | | | 5 SHADE TREES TO BE PROVIDED ON THE SITE ARE NOT TO BE | | | COUNTED TOWARD OPEN SPACE CANOPY REQUIREMENTS. | | | 2. SATISFIED. THE WEST STREETSCAPE DOES NOT MEET THE | | | REQUIREMENTS FOR PLACEMENT OR NUMBER OF THE REQUIRED | | | STREET TREES ALONG THE CURB. THE MEDIAN PLACEMENT OF | | | TREES DO NOT MEET THE INTENT OF PROVIDING TREE CANOPY | | | OVER THE PEDESTRIAN AREAS OF THE STREETSCAPE. | | | THE RESPONSE TO COMMENT DID NOT INCLUDE THE WAIVER | | | REQUEST FOR THE WEST STREETSCAPE SEGMENT AS INDICATED | | | ON SHEET LP-1. 4 TREES ARE PROVIDED IN THE STREETSCAPE, | | | STAFF DISCUSSED AND REQUESTS ADDING ONE ADDITIONAL TREE | | | ON EACH SIDE OF THE DROPOFF CANOPY TO PROVIDE | | | ADDITIONAL SHADE FOR THE SIDEWALK AREA AND ADDING THE | | | REMAINING 3 TREES TO THE PLAZA PUBLIC OPEN SPACE TO | | | PROVIDE ADDITIONAL PEDESTRIAN SHADE. THIS MEETS THE | | | INTENT OF THE STREETSCAPE REQUIREMENTS. | | | TREES ADDED IN QUADRILLE MEDIAN DO NOT CONTRIBUTE TO | | | SHADE FOR PEDESTRIANS BUT WILL IMPROVE THE AESTHETICS. | | | STAFF SUGGESTS THE USE OF BULNESIA ARBOREA TO FOLLOW | | | THE PATTERN ON QUADRILLE AND ALABAMA AVENUE ADJACENT TO | | | RESTORATION HARDWARE SITE. | | | 10/31/22: THE 5 ADDITIONAL SHADE TREES NEED TO BE | | | PROVIDED ON SITE AND IDENTIFIED ON THE LANDSCAPE PLAN. | | | | | | 3. SATISFIED. PROVIDE PRELIMINARY FDOT APPROVAL FOR ALL | | | TREES IN THE FDOT RIGHT OF WAY. | | | THE STREET TREES EAST OF THE GARAGE ENTRANCE ON | | | LAKEVIEW AND THE STREET TREES WEST OF THE GARAGE | | | ENTRANCE ON OKEECHOBEE APPEAR TO BE IN FDOT SIGHT LINES | | | PER THE ENGINEERING PLANS. THESE TREES NEED TO BE MOVED | | | OUT OF THE SIGHT LINES CLOSER TO THE BUILDING. THERE | | | MAY BE DRAINAGE LINES ON THE OKEECHOBEE SIDE THAT WILL | | | ALSO HAVE TO BE MOVED TO ACCOMMODATE THE TREES. | | | 10/31/22 INDICATE IF THE STREETSCAPE PLAN SUBMITTED | | | WILL MEET FDOT PERMITTING REQUIREMENTS. | | | | | | | | | CONDITIONS OF APPROVAL | | | | | | 1. EXFILTRATION AND DRAINAGE SYSTEM LOCATIONS WILL BE | | | DESIGNED TO AVOID CONFLICTS WITH THE STREET TREES AND | | | PLAZA TREES AS SHOWN IN THE APPROVED VERSION OF THE | | | LANDSCAPE PLAN. | | | 2. STREET TREES AND LANDSCAPING WILL REQUIRE A FDOT | | | PERMIT. | | | | | | THESE CONDITIONS ARE IN ADDITION TO THE PREVIOUS | | | CONDITIONS. | | | |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
5 |
Status |
F |
Date |
10-31-2022 |
|
|
Cont ID |
|
| Sent By |
rcaranci |
Date |
10-31-2022 |
Time |
12:48 |
Rev Time |
0.00 |
| Received By |
rcaranci |
Date |
10-31-2022 |
Time |
12:48 |
Sent To |
|
|
| Notes |
| 2022-10-31 12:51:46 | FROM: RAY CARANCI, SENIOR LANDSCAPE PLANNER | | | 561-822-1462 | | | PROJECT: WEST PALM POINT Z20120016 | | | OCTOBER 31, 2022 | | | I HAVE REVIEWED THE ABOVE REFERENCED PETITION, AND | | | PROVIDE THE FOLLOWING COMMENTS FOR THE FINAL SITE PLAN | | | APPROVAL: | | | | | | | | | 1. CONDITIONALLY SATISFIED. LIST THE TREE SPECIES AND | | | SQUARE FOOTAGE CREDIT FOR THE OPEN SPACE SQUARE FOOTAGE | | | CALCULATIONS FOR EACH OPEN SPACE. PERCENTAGES DO NOT | | | MEET THE REQUIREMENTS FOR THE ENTIRE PRIVATE OPEN SPACE | | | SO AN AREA MEETING THE REQUIREMENTS NEEDS TO BE | | | DESIGNATED. | | | OS-1 OPEN SPACE PLAN DOES NOT MATCH THE LANDSCAPE PLAN | | | SHEET LP-1 FOR THE NUMBER OF CLUSIA TREES AT THE | | | NORTHEAST CORNER OF THE PLAZA. | | | NEEDS TO BE BASED ON PROVIDED. DESIGNATE AN AREA THAT | | | MEETS THE MINIMUM OPEN SPACE AREA REQUIRED AND THEN | | | PROVIDE PERCENTAGES OF VEGETATED AREA AND TREE CANOPY | | | FOR THAT AREA. 17,895 SQ FT REQUIRES 4,473.75 SQ FT | | | VEGETATED AREA AND 5,368.5 SQ FT TREE CANOPY, WHICH ARE | | | NOT MET. | | | THE PUBLIC OPEN SPACE PLAZA NEEDS TO MEET THE CRITERIA | | | ABOVE. THE PRIVATE OPEN SPACE ROOFTOP GARDEN HAS SOME | | | TREE CANOPY SQUARE FOOTAGE CALCULATIONS THAT ARE OFF | | | AND LIGUSTRUMS ARE NOT COUNTED. | | | 10/31/22: THE AREA DESIGNATED AS PUBLIC OPEN SPACE HAS | | | CHANGED FROM THE APPROVAL. MAKE THE FOLLOWING | | | CORRECTIONS TO THE PLAN: | | | ??? THE AREA CANNOT HAVE THE SMALL PIECE SPLIT OFF FOR | | | THE PASEO, AS IT WOULD HAVE TO MEET THE OPEN SPACE | | | REQUIREMENTS ON ITS OWN IF SEPARATED. IF CHANGING THE | | | DESIGNATED AREA, SHOW ALL THE REQUIREMENTS ARE MET FOR | | | THE NEW AREA. | | | ??? ADDITIONAL TREES PROVIDED FOR THE CONDITION FOR THE | | | 5 SHADE TREES TO BE PROVIDED ON THE SITE ARE NOT TO BE | | | COUNTED TOWARD OPEN SPACE CANOPY REQUIREMENTS. | | | 2. CONDITIONALLY SATISFIED. THE WEST STREETSCAPE DOES | | | NOT MEET THE REQUIREMENTS FOR PLACEMENT OR NUMBER OF | | | THE REQUIRED STREET TREES ALONG THE CURB. THE MEDIAN | | | PLACEMENT OF TREES DO NOT MEET THE INTENT OF PROVIDING | | | TREE CANOPY OVER THE PEDESTRIAN AREAS OF THE | | | STREETSCAPE. | | | THE RESPONSE TO COMMENT DID NOT INCLUDE THE WAIVER | | | REQUEST FOR THE WEST STREETSCAPE SEGMENT AS INDICATED | | | ON SHEET LP-1. 4 TREES ARE PROVIDED IN THE STREETSCAPE, | | | STAFF DISCUSSED AND REQUESTS ADDING ONE ADDITIONAL TREE | | | ON EACH SIDE OF THE DROPOFF CANOPY TO PROVIDE | | | ADDITIONAL SHADE FOR THE SIDEWALK AREA AND ADDING THE | | | REMAINING 3 TREES TO THE PLAZA PUBLIC OPEN SPACE TO | | | PROVIDE ADDITIONAL PEDESTRIAN SHADE. THIS MEETS THE | | | INTENT OF THE STREETSCAPE REQUIREMENTS. | | | TREES ADDED IN QUADRILLE MEDIAN DO NOT CONTRIBUTE TO | | | SHADE FOR PEDESTRIANS BUT WILL IMPROVE THE AESTHETICS. | | | STAFF SUGGESTS THE USE OF BULNESIA ARBOREA TO FOLLOW | | | THE PATTERN ON QUADRILLE AND ALABAMA AVENUE ADJACENT TO | | | RESTORATION HARDWARE SITE. | | | 10/31/22: THE 5 ADDITIONAL SHADE TREES NEED TO BE | | | PROVIDED ON SITE AND IDENTIFIED ON THE LANDSCAPE PLAN. | | | | | | 3. CONDITIONALLY SATISFIED. PROVIDE PRELIMINARY FDOT | | | APPROVAL FOR ALL TREES IN THE FDOT RIGHT OF WAY. | | | THE STREET TREES EAST OF THE GARAGE ENTRANCE ON | | | LAKEVIEW AND THE STREET TREES WEST OF THE GARAGE | | | ENTRANCE ON OKEECHOBEE APPEAR TO BE IN FDOT SIGHT LINES | | | PER THE ENGINEERING PLANS. THESE TREES NEED TO BE MOVED | | | OUT OF THE SIGHT LINES CLOSER TO THE BUILDING. THERE | | | MAY BE DRAINAGE LINES ON THE OKEECHOBEE SIDE THAT WILL | | | ALSO HAVE TO BE MOVED TO ACCOMMODATE THE TREES. | | | 10/31/22 INDICATE IF THE STREETSCAPE PLAN SUBMITTED | | | WILL MEET FDOT PERMITTING REQUIREMENTS. | | | | | | |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
4 |
Status |
P |
Date |
01-10-2022 |
|
|
Cont ID |
|
| Sent By |
rcaranci |
Date |
01-10-2022 |
Time |
11:18 |
Rev Time |
0.00 |
| Received By |
rcaranci |
Date |
01-10-2022 |
Time |
11:18 |
Sent To |
|
|
| Notes |
| 2022-01-10 11:19:02 | FROM: RAY CARANCI, SENIOR LANDSCAPE PLANNER | | | 561-822-1462 | | | PROJECT: WEST PALM POINT Z20120016 | | | JANUARY 10, 2022 | | | I HAVE REVIEWED THE ABOVE REFERENCED PETITION, AND | | | PROVIDE THE FOLLOWING COMMENTS: | | | | | | 1. MAKE THE FOLLOWING CORRECTIONS TO THE TREE | | | DISPOSITION PLAN AND THE TREE INVENTORY LIST: | | | ? CONDITIONALLY SATISFIED. EXPLAIN WHERE THE RELOCATED | | | ROYAL PALMS WILL BE PLANTED | | | ? SATISFIED. #12 FICUS WOULD BE 300 SQ FT MITIGATION | | | ? SATISFIED. #13 WASHINGTONIA PALM IS CATEGORY 4, SO 50 | | | SQ FT MITIGATION | | | ? SATISFIED. CORRECT SPELLING FOR MITIGATION REQ (SF) | | | COLUMN | | | | | | 2. CONDITIONALLY SATISFIED. LIST THE TREE SPECIES AND | | | SQUARE FOOTAGE CREDIT FOR THE OPEN SPACE SQUARE FOOTAGE | | | CALCULATIONS FOR EACH OPEN SPACE. PERCENTAGES DO NOT | | | MEET THE REQUIREMENTS FOR THE ENTIRE PRIVATE OPEN SPACE | | | SO AN AREA MEETING THE REQUIREMENTS NEEDS TO BE | | | DESIGNATED. | | | OS-1 OPEN SPACE PLAN DOES NOT MATCH THE LANDSCAPE PLAN | | | SHEET LP-1 FOR THE NUMBER OF CLUSIA TREES AT THE | | | NORTHEAST CORNER OF THE PLAZA. | | | NEEDS TO BE BASED ON PROVIDED. DESIGNATE AN AREA THAT | | | MEETS THE MINIMUM OPEN SPACE AREA REQUIRED AND THEN | | | PROVIDE PERCENTAGES OF VEGETATED AREA AND TREE CANOPY | | | FOR THAT AREA. 17,895 SQ FT REQUIRES 4,473.75 SQ FT | | | VEGETATED AREA AND 5,368.5 SQ FT TREE CANOPY, WHICH ARE | | | NOT MET. | | | THE PUBLIC OPEN SPACE PLAZA NEEDS TO MEET THE CRITERIA | | | ABOVE. THE PRIVATE OPEN SPACE ROOFTOP GARDEN HAS SOME | | | TREE CANOPY SQUARE FOOTAGE CALCULATIONS THAT ARE OFF | | | AND LIGUSTRUMS ARE NOT COUNTED. | | | | | | 3. SATISFIED. PER SECTION 94-113, CALCULATIONS FOR | | | NUMBER OF REQUIRED STREET TREES NEED TO BE CORRECTED. | | | LIST TOTAL LENGTH OF EACH PROPERTY LINE SEGMENT, DIVIDE | | | BY 30, THEN INDICATE THE NUMBER OF TREES REQUIRED, | | | ROUNDING UP FOR ANY PORTION LEFT. ACCESSWAYS ARE NOT | | | DEDUCTED. | | | | | | 4. CONDITIONALLY SATISFIED. THE WEST STREETSCAPE DOES | | | NOT MEET THE REQUIREMENTS FOR PLACEMENT OR NUMBER OF | | | THE REQUIRED STREET TREES ALONG THE CURB. THE MEDIAN | | | PLACEMENT OF TREES DO NOT MEET THE INTENT OF PROVIDING | | | TREE CANOPY OVER THE PEDESTRIAN AREAS OF THE | | | STREETSCAPE. | | | THE RESPONSE TO COMMENT DID NOT INCLUDE THE WAIVER | | | REQUEST FOR THE WEST STREETSCAPE SEGMENT AS INDICATED | | | ON SHEET LP-1. 4 TREES ARE PROVIDED IN THE STREETSCAPE, | | | STAFF DISCUSSED AND REQUESTS ADDING ONE ADDITIONAL TREE | | | ON EACH SIDE OF THE DROPOFF CANOPY TO PROVIDE | | | ADDITIONAL SHADE FOR THE SIDEWALK AREA AND ADDING THE | | | REMAINING 3 TREES TO THE PLAZA PUBLIC OPEN SPACE TO | | | PROVIDE ADDITIONAL PEDESTRIAN SHADE. THIS MEETS THE | | | INTENT OF THE STREETSCAPE REQUIREMENTS. | | | TREES ADDED IN QUADRILLE MEDIAN DO NOT CONTRIBUTE TO | | | SHADE FOR PEDESTRIANS BUT WILL IMPROVE THE AESTHETICS. | | | STAFF SUGGESTS THE USE OF BULNESIA ARBOREA TO FOLLOW | | | THE PATTERN ON QUADRILLE AND ALABAMA AVENUE ADJACENT TO | | | RESTORATION HARDWARE SITE. | | | | | | | | | 5. SATISFIED. FLORIDA FRIENDLY DESIGN OPTIONS POINTS | | | CANNOT BE COUNTED FOR 51% OR MORE NATIVE GROUNDCOVER, | | | AS THEY ARE ALL NON-NATIVE. POINTS CANNOT BE COUNTED | | | FOR 51% OR MORE NATIVE SHRUBS, AS THEY ARE ALL | | | NON-NATIVE. | | | | | | 6. SATISFIED. CORRECT IN THE PLANT LIST: NATCHEZ CRAPE | | | MYRTLE IS NOT FLORIDA NATIVE. AGAVE AMERICANA IS NOT | | | FLORIDA NATIVE. | | | | | | 7. SATISFIED. SHOW LOCATIONS OF UTILITY LINES ON | | | LANDSCAPE PLAN, ALSO LOCATIONS OF VALVES AND BACKFLOW | | | PREVENTERS AND FPL TRANSFORMERS. SCREENING MUST BE | | | PROVIDED. THERE ARE CONFLICTS BETWEEN UTILITIES AND | | | LANDSCAPING THAT WILL HAVE TO BE RESOLVED. | | | | | | 8. SATISFIED. PER SECTION 94-113, ADJUST LOCATIONS OF | | | REQUIRED STRUCTURAL SOIL TO ONLY SHOW UNDER HARDSCAPE | | | ADJACENT TO STREET TREES. AREA FOR STRUCTURAL SOIL AND | | | PLANTING AREA SHOULD BE APPROXIMATELY 14 FEET IN LENGTH | | | AND 9 FEET IN WIDTH RELATIVE TO THE BACK OF CURB. | | | STRUCTURAL SOIL DETAIL IS TO SHOW THE CONSTRUCTION | | | CROSS SECTION FOR DEPTH OF 36 INCHES, AND PLANTING SOIL | | | IN THE PLANTING AREA. DO NOT INCLUDE TREE GRATES UNLESS | | | NEEDED FOR ADA TRAVEL WIDTH. CORRECT THE DETAIL TO | | | REFLECT THIS. | | | | | | ADDITIONAL COMMENTS 5/4/21: | | | | | | 9. SATISFIED. CORRECT THE TREES PROVIDED FOR MITIGATION | | | PROVIDED ON THE TREE DISPOSITION SHEET TD-1 TO MATCH | | | THE PLANT LIST. CATHEDRAL OAK, NOT HIGHRISE OAK. | | | 10. CONDITIONALLY SATISFIED. PROVIDE PRELIMINARY FDOT | | | APPROVAL FOR ALL TREES IN THE FDOT RIGHT OF WAY. | | | THE STREET TREES EAST OF THE GARAGE ENTRANCE ON | | | LAKEVIEW AND THE STREET TREES WEST OF THE GARAGE | | | ENTRANCE ON OKEECHOBEE APPEAR TO BE IN FDOT SIGHT LINES | | | PER THE ENGINEERING PLANS. THESE TREES NEED TO BE MOVED | | | OUT OF THE SIGHT LINES CLOSER TO THE BUILDING. THERE | | | MAY BE DRAINAGE LINES ON THE OKEECHOBEE SIDE THAT WILL | | | ALSO HAVE TO BE MOVED TO ACCOMMODATE THE TREES. | | | | | | CONDITIONS OF APPROVAL | | | 1. PRIOR TO THE REMOVAL OR RELOCATION OF ANY TREES ON | | | THE PROPERTY, A TREE ALTERATION PERMIT SHALL BE | | | SUBMITTED, REVIEWED AND APPROVED BY THE DEVELOPMENT | | | SERVICES DEPARTMENT, PLANNING DIVISION. LOCATIONS OF | | | ROYAL PALMS TO BE TRANSPLANTED WILL BE DETERMINED AT | | | TIME OF PERMIT. | | | 2. THE APPLICANT, SUCCESSORS AND ASSIGNS SHALL BE | | | RESPONSIBLE FOR THE PERMITTING AND INSTALLATION OF THE | | | STREET TREES AND RIGHT OF WAY LANDSCAPING AND | | | IRRIGATION APPROVED WITH THIS PETITION. | | | 3. THE APPLICANT, SUCCESSORS AND ASSIGNS SHALL BE | | | RESPONSIBLE FOR THE MAINTENANCE OF THE ROAD RIGHT OF | | | WAY LANDSCAPING AND IRRIGATION. THIS WILL BE THROUGH A | | | SEPARATE MAINTENANCE AGREEMENT WITH THE CITY. | | | |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
3 |
Status |
F |
Date |
12-21-2021 |
|
|
Cont ID |
|
| Sent By |
rcaranci |
Date |
12-21-2021 |
Time |
13:23 |
Rev Time |
0.00 |
| Received By |
rcaranci |
Date |
12-20-2021 |
Time |
16:11 |
Sent To |
|
|
| Notes |
| 2021-12-21 13:23:58 | FROM: RAY CARANCI, SENIOR LANDSCAPE PLANNER | | | 561-822-1462 | | | PROJECT: WEST PALM POINT Z20120016 | | | DECEMBER 21, 2021 | | | I HAVE REVIEWED THE ABOVE REFERENCED PETITION, AND | | | PROVIDE THE FOLLOWING COMMENTS: | | | | | | 1. MAKE THE FOLLOWING CORRECTIONS TO THE TREE | | | DISPOSITION PLAN AND THE TREE INVENTORY LIST: | | | ? CONDITIONALLY SATISFIED. EXPLAIN WHERE THE RELOCATED | | | ROYAL PALMS WILL BE PLANTED | | | ? SATISFIED. #12 FICUS WOULD BE 300 SQ FT MITIGATION | | | ? SATISFIED. #13 WASHINGTONIA PALM IS CATEGORY 4, SO 50 | | | SQ FT MITIGATION | | | ? SATISFIED. CORRECT SPELLING FOR MITIGATION REQ (SF) | | | COLUMN | | | | | | 2. PARTIALLY SATISFIED. LIST THE TREE SPECIES AND | | | SQUARE FOOTAGE CREDIT FOR THE OPEN SPACE SQUARE FOOTAGE | | | CALCULATIONS FOR EACH OPEN SPACE. PERCENTAGES DO NOT | | | MEET THE REQUIREMENTS FOR THE ENTIRE PRIVATE OPEN SPACE | | | SO AN AREA MEETING THE REQUIREMENTS NEEDS TO BE | | | DESIGNATED. | | | OS-1 OPEN SPACE PLAN DOES NOT MATCH THE LANDSCAPE PLAN | | | SHEET LP-1 FOR THE NUMBER OF CLUSIA TREES AT THE | | | NORTHEAST CORNER OF THE PLAZA. | | | NEEDS TO BE BASED ON PROVIDED. DESIGNATE AN AREA THAT | | | MEETS THE MINIMUM OPEN SPACE AREA REQUIRED AND THEN | | | PROVIDE PERCENTAGES OF VEGETATED AREA AND TREE CANOPY | | | FOR THAT AREA. 17,895 SQ FT REQUIRES 4,473.75 SQ FT | | | VEGETATED AREA AND 5,368.5 SQ FT TREE CANOPY, WHICH ARE | | | NOT MET. | | | THE PUBLIC OPEN SPACE PLAZA NEEDS TO MEET THE CRITERIA | | | ABOVE. THE PRIVATE OPEN SPACE ROOFTOP GARDEN HAS SOME | | | TREE CANOPY SQUARE FOOTAGE CALCULATIONS THAT ARE OFF | | | AND LIGUSTRUMS ARE NOT COUNTED. | | | | | | 3. SATISFIED. PER SECTION 94-113, CALCULATIONS FOR | | | NUMBER OF REQUIRED STREET TREES NEED TO BE CORRECTED. | | | LIST TOTAL LENGTH OF EACH PROPERTY LINE SEGMENT, DIVIDE | | | BY 30, THEN INDICATE THE NUMBER OF TREES REQUIRED, | | | ROUNDING UP FOR ANY PORTION LEFT. ACCESSWAYS ARE NOT | | | DEDUCTED. | | | | | | 4. PARTIALLY SATISFIED. THE WEST STREETSCAPE DOES NOT | | | MEET THE REQUIREMENTS FOR PLACEMENT OR NUMBER OF THE | | | REQUIRED STREET TREES ALONG THE CURB. THE MEDIAN | | | PLACEMENT OF TREES DO NOT MEET THE INTENT OF PROVIDING | | | TREE CANOPY OVER THE PEDESTRIAN AREAS OF THE | | | STREETSCAPE. | | | THE RESPONSE TO COMMENT DID NOT INCLUDE THE WAIVER | | | REQUEST FOR THE WEST STREETSCAPE SEGMENT AS INDICATED | | | ON SHEET LP-1. 4 TREES ARE PROVIDED IN THE STREETSCAPE, | | | STAFF DISCUSSED AND REQUESTS ADDING ONE ADDITIONAL TREE | | | ON EACH SIDE OF THE DROPOFF CANOPY TO PROVIDE | | | ADDITIONAL SHADE FOR THE SIDEWALK AREA AND ADDING THE | | | REMAINING 3 TREES TO THE PLAZA PUBLIC OPEN SPACE TO | | | PROVIDE ADDITIONAL PEDESTRIAN SHADE. THIS MEETS THE | | | INTENT OF THE STREETSCAPE REQUIREMENTS. | | | TREES ADDED IN QUADRILLE MEDIAN DO NOT CONTRIBUTE TO | | | SHADE FOR PEDESTRIANS BUT WILL IMPROVE THE AESTHETICS. | | | STAFF SUGGESTS THE USE OF BULNESIA ARBOREA TO FOLLOW | | | THE PATTERN ON QUADRILLE AND ALABAMA AVENUE ADJACENT TO | | | RESTORATION HARDWARE SITE. | | | | | | | | | 5. SATISFIED. FLORIDA FRIENDLY DESIGN OPTIONS POINTS | | | CANNOT BE COUNTED FOR 51% OR MORE NATIVE GROUNDCOVER, | | | AS THEY ARE ALL NON-NATIVE. POINTS CANNOT BE COUNTED | | | FOR 51% OR MORE NATIVE SHRUBS, AS THEY ARE ALL | | | NON-NATIVE. | | | | | | 6. SATISFIED. CORRECT IN THE PLANT LIST: NATCHEZ CRAPE | | | MYRTLE IS NOT FLORIDA NATIVE. AGAVE AMERICANA IS NOT | | | FLORIDA NATIVE. | | | | | | 7. SATISFIED. SHOW LOCATIONS OF UTILITY LINES ON | | | LANDSCAPE PLAN, ALSO LOCATIONS OF VALVES AND BACKFLOW | | | PREVENTERS AND FPL TRANSFORMERS. SCREENING MUST BE | | | PROVIDED. THERE ARE CONFLICTS BETWEEN UTILITIES AND | | | LANDSCAPING THAT WILL HAVE TO BE RESOLVED. | | | | | | 8. SATISFIED. PER SECTION 94-113, ADJUST LOCATIONS OF | | | REQUIRED STRUCTURAL SOIL TO ONLY SHOW UNDER HARDSCAPE | | | ADJACENT TO STREET TREES. AREA FOR STRUCTURAL SOIL AND | | | PLANTING AREA SHOULD BE APPROXIMATELY 14 FEET IN LENGTH | | | AND 9 FEET IN WIDTH RELATIVE TO THE BACK OF CURB. | | | STRUCTURAL SOIL DETAIL IS TO SHOW THE CONSTRUCTION | | | CROSS SECTION FOR DEPTH OF 36 INCHES, AND PLANTING SOIL | | | IN THE PLANTING AREA. DO NOT INCLUDE TREE GRATES UNLESS | | | NEEDED FOR ADA TRAVEL WIDTH. CORRECT THE DETAIL TO | | | REFLECT THIS. | | | | | | ADDITIONAL COMMENTS 5/4/21: | | | | | | 9. SATISFIED. CORRECT THE TREES PROVIDED FOR MITIGATION | | | PROVIDED ON THE TREE DISPOSITION SHEET TD-1 TO MATCH | | | THE PLANT LIST. CATHEDRAL OAK, NOT HIGHRISE OAK. | | | 10. PARTIALLY SATISFIED. PROVIDE PRELIMINARY FDOT | | | APPROVAL FOR ALL TREES IN THE FDOT RIGHT OF WAY. | | | THE STREET TREES EAST OF THE GARAGE ENTRANCE ON | | | LAKEVIEW AND THE STREET TREES WEST OF THE GARAGE | | | ENTRANCE ON OKEECHOBEE APPEAR TO BE IN FDOT SIGHT LINES | | | PER THE ENGINEERING PLANS. THESE TREES NEED TO BE MOVED | | | OUT OF THE SIGHT LINES CLOSER TO THE BUILDING. THERE | | | MAY BE DRAINAGE LINES ON THE OKEECHOBEE SIDE THAT WILL | | | ALSO HAVE TO BE MOVED TO ACCOMMODATE THE TREES. | | | | | | CONDITIONS OF APPROVAL | | | 1. PRIOR TO THE REMOVAL OR RELOCATION OF ANY TREES ON | | | THE PROPERTY, A TREE ALTERATION PERMIT SHALL BE | | | SUBMITTED, REVIEWED AND APPROVED BY THE DEVELOPMENT | | | SERVICES DEPARTMENT, PLANNING DIVISION. LOCATIONS OF | | | ROYAL PALMS TO BE TRANSPLANTED WILL BE DETERMINED AT | | | TIME OF PERMIT. | | | 2. THE APPLICANT, SUCCESSORS AND ASSIGNS SHALL BE | | | RESPONSIBLE FOR THE PERMITTING AND INSTALLATION OF THE | | | STREET TREES AND RIGHT OF WAY LANDSCAPING AND | | | IRRIGATION APPROVED WITH THIS PETITION. | | | 3. THE APPLICANT, SUCCESSORS AND ASSIGNS SHALL BE | | | RESPONSIBLE FOR THE MAINTENANCE OF THE ROAD RIGHT OF | | | WAY LANDSCAPING AND IRRIGATION. THIS WILL BE THROUGH A | | | SEPARATE MAINTENANCE AGREEMENT WITH THE CITY. | | | 4. LOCATIONS OF ROOT BARRIERS SHALL NOT BLOCK TREE | | | ROOTS FROM STRUCTURAL SOIL AREAS OR THERE IS NO POINT | | | IN PROVIDING THE STRUCTURAL SOIL. | | | |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
2 |
Status |
F |
Date |
05-05-2021 |
|
|
Cont ID |
|
| Sent By |
rcaranci |
Date |
05-05-2021 |
Time |
12:20 |
Rev Time |
0.00 |
| Received By |
rcaranci |
Date |
05-05-2021 |
Time |
12:20 |
Sent To |
|
|
| Notes |
| 2021-05-05 12:21:52 | FROM: RAY CARANCI, SENIOR LANDSCAPE PLANNER | | | 561-822-1462 | | | PROJECT: WEST PALM POINT Z20120016 | | | MAY 5, 2021 | | | I HAVE REVIEWED THE ABOVE REFERENCED PETITION, AND | | | PROVIDE THE FOLLOWING COMMENTS: | | | | | | 1. MAKE THE FOLLOWING CORRECTIONS TO THE TREE | | | DISPOSITION PLAN AND THE TREE INVENTORY LIST: | | | ? CONDITIONALLY SATISFIED. EXPLAIN WHERE THE RELOCATED | | | ROYAL PALMS WILL BE PLANTED | | | ? SATISFIED. #12 FICUS WOULD BE 300 SQ FT MITIGATION | | | ? SATISFIED. #13 WASHINGTONIA PALM IS CATEGORY 4, SO 50 | | | SQ FT MITIGATION | | | ? SATISFIED. CORRECT SPELLING FOR MITIGATION REQ (SF) | | | COLUMN | | | | | | 2. PARTIALLY SATISFIED. LIST THE TREE SPECIES AND | | | SQUARE FOOTAGE CREDIT FOR THE OPEN SPACE SQUARE FOOTAGE | | | CALCULATIONS FOR EACH OPEN SPACE. PERCENTAGES DO NOT | | | MEET THE REQUIREMENTS FOR THE ENTIRE PRIVATE OPEN SPACE | | | SO AN AREA MEETING THE REQUIREMENTS NEEDS TO BE | | | DESIGNATED. | | | OS-1 OPEN SPACE PLAN DOES NOT MATCH THE LANDSCAPE PLAN | | | SHEET LP-1 FOR THE NUMBER OF CLUSIA TREES AT THE | | | NORTHEAST CORNER OF THE PLAZA. | | | | | | 3. SATISFIED. PER SECTION 94-113, CALCULATIONS FOR | | | NUMBER OF REQUIRED STREET TREES NEED TO BE CORRECTED. | | | LIST TOTAL LENGTH OF EACH PROPERTY LINE SEGMENT, DIVIDE | | | BY 30, THEN INDICATE THE NUMBER OF TREES REQUIRED, | | | ROUNDING UP FOR ANY PORTION LEFT. ACCESSWAYS ARE NOT | | | DEDUCTED. | | | | | | 4. PARTIALLY SATISFIED. THE WEST STREETSCAPE DOES NOT | | | MEET THE REQUIREMENTS FOR PLACEMENT OR NUMBER OF THE | | | REQUIRED STREET TREES ALONG THE CURB. THE MEDIAN | | | PLACEMENT OF TREES DO NOT MEET THE INTENT OF PROVIDING | | | TREE CANOPY OVER THE PEDESTRIAN AREAS OF THE | | | STREETSCAPE. | | | | | | THE RESPONSE TO COMMENT DID NOT INCLUDE THE WAIVER | | | REQUEST FOR THE WEST STREETSCAPE SEGMENT AS INDICATED | | | ON SHEET LP-1. 4 TREES ARE PROVIDED IN THE STREETSCAPE, | | | STAFF DISCUSSED AND REQUESTS ADDING ONE ADDITIONAL TREE | | | ON EACH SIDE OF THE DROPOFF CANOPY TO PROVIDE | | | ADDITIONAL SHADE FOR THE SIDEWALK AREA AND ADDING THE | | | REMAINING 3 TREES TO THE PLAZA PUBLIC OPEN SPACE TO | | | PROVIDE ADDITIONAL PEDESTRIAN SHADE. THIS MEETS THE | | | INTENT OF THE STREETSCAPE REQUIREMENTS. | | | TREES ADDED IN QUADRILLE MEDIAN DO NOT CONTRIBUTE TO | | | SHADE FOR PEDESTRIANS BUT WILL IMPROVE THE AESTHETICS. | | | STAFF SUGGESTS THE USE OF BULNESIA ARBOREA TO FOLLOW | | | THE PATTERN ON QUADRILLE AND ALABAMA AVENUE ADJACENT TO | | | RESTORATION HARDWARE SITE. | | | | | | | | | | | | 5. SATISFIED. FLORIDA FRIENDLY DESIGN OPTIONS POINTS | | | CANNOT BE COUNTED FOR 51% OR MORE NATIVE GROUNDCOVER, | | | AS THEY ARE ALL NON-NATIVE. POINTS CANNOT BE COUNTED | | | FOR 51% OR MORE NATIVE SHRUBS, AS THEY ARE ALL | | | NON-NATIVE. | | | | | | 6. SATISFIED. CORRECT IN THE PLANT LIST: NATCHEZ CRAPE | | | MYRTLE IS NOT FLORIDA NATIVE. AGAVE AMERICANA IS NOT | | | FLORIDA NATIVE. | | | | | | 7. SATISFIED. SHOW LOCATIONS OF UTILITY LINES ON | | | LANDSCAPE PLAN, ALSO LOCATIONS OF VALVES AND BACKFLOW | | | PREVENTERS AND FPL TRANSFORMERS. SCREENING MUST BE | | | PROVIDED. THERE ARE CONFLICTS BETWEEN UTILITIES AND | | | LANDSCAPING THAT WILL HAVE TO BE RESOLVED. | | | | | | 8. SATISFIED. PER SECTION 94-113, ADJUST LOCATIONS OF | | | REQUIRED STRUCTURAL SOIL TO ONLY SHOW UNDER HARDSCAPE | | | ADJACENT TO STREET TREES. AREA FOR STRUCTURAL SOIL AND | | | PLANTING AREA SHOULD BE APPROXIMATELY 14 FEET IN LENGTH | | | AND 9 FEET IN WIDTH RELATIVE TO THE BACK OF CURB. | | | STRUCTURAL SOIL DETAIL IS TO SHOW THE CONSTRUCTION | | | CROSS SECTION FOR DEPTH OF 36 INCHES, AND PLANTING SOIL | | | IN THE PLANTING AREA. DO NOT INCLUDE TREE GRATES UNLESS | | | NEEDED FOR ADA TRAVEL WIDTH. CORRECT THE DETAIL TO | | | REFLECT THIS. | | | | | | ADDITIONAL COMMENTS 5/4/21: | | | | | | 9. CORRECT THE TREES PROVIDED FOR MITIGATION PROVIDED | | | ON THE TREE DISPOSITION SHEET TD-1 TO MATCH THE PLANT | | | LIST. CATHEDRAL OAK, NOT HIGHRISE OAK. | | | | | | 10. PROVIDE PRELIMINARY FDOT APPROVAL FOR ALL TREES IN | | | THE FDOT RIGHT OF WAY. | | | | | | CONDITIONS OF APPROVAL | | | 1. PRIOR TO THE REMOVAL OR RELOCATION OF ANY TREES ON | | | THE PROPERTY, A TREE ALTERATION PERMIT SHALL BE | | | SUBMITTED, REVIEWED AND APPROVED BY THE DEVELOPMENT | | | SERVICES DEPARTMENT, PLANNING DIVISION. LOCATIONS OF | | | ROYAL PALMS TO BE TRANSPLANTED WILL BE DETERMINED AT | | | TIME OF PERMIT. | | | 2. THE APPLICANT, SUCCESSORS AND ASSIGNS SHALL BE | | | RESPONSIBLE FOR THE PERMITTING AND INSTALLATION OF THE | | | STREET TREES AND RIGHT OF WAY LANDSCAPING AND | | | IRRIGATION APPROVED WITH THIS PETITION. | | | 3. THE APPLICANT, SUCCESSORS AND ASSIGNS SHALL BE | | | RESPONSIBLE FOR THE MAINTENANCE OF THE ROAD RIGHT OF | | | WAY LANDSCAPING AND IRRIGATION. THIS WILL BE THROUGH A | | | SEPARATE MAINTENANCE AGREEMENT WITH THE CITY. | | | |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
1 |
Status |
F |
Date |
01-13-2021 |
|
|
Cont ID |
|
| Sent By |
rcaranci |
Date |
01-13-2021 |
Time |
17:33 |
Rev Time |
0.00 |
| Received By |
rcaranci |
Date |
01-13-2021 |
Time |
17:33 |
Sent To |
|
|
| Notes |
| 2021-01-13 17:33:56 | FROM: RAY CARANCI, SENIOR LANDSCAPE PLANNER | | | 561-822-1462 | | | PROJECT: WEST PALM POINT Z20120016 | | | JANUARY 13, 2021 | | | I HAVE REVIEWED THE ABOVE REFERENCED PETITION, AND | | | PROVIDE THE FOLLOWING COMMENTS: | | | | | | 1. MAKE THE FOLLOWING CORRECTIONS TO THE TREE | | | DISPOSITION PLAN AND THE TREE INVENTORY LIST: | | | ? EXPLAIN WHERE THE RELOCATED ROYAL PALMS WILL BE | | | PLANTED | | | ? #12 FICUS WOULD BE 300 SQ FT MITIGATION | | | ? #13 WASHINGTONIA PALM IS CATEGORY 4, SO 50 SQ FT | | | MITIGATION | | | ? CORRECT SPELLING FOR MITIGATION REQ (SF) COLUMN | | | | | | 2. LIST THE TREE SPECIES AND SQUARE FOOTAGE CREDIT FOR | | | THE OPEN SPACE SQUARE FOOTAGE CALCULATIONS FOR EACH | | | OPEN SPACE. PERCENTAGES DO NOT MEET THE REQUIREMENTS | | | FOR THE ENTIRE PRIVATE OPEN SPACE SO AN AREA MEETING | | | THE REQUIREMENTS NEEDS TO BE DESIGNATED. | | | | | | 3. PER SECTION 94-113, CALCULATIONS FOR NUMBER OF | | | REQUIRED STREET TREES NEED TO BE CORRECTED. LIST TOTAL | | | LENGTH OF EACH PROPERTY LINE SEGMENT, DIVIDE BY 30, | | | THEN INDICATE THE NUMBER OF TREES REQUIRED, ROUNDING UP | | | FOR ANY PORTION LEFT. ACCESSWAYS ARE NOT DEDUCTED. | | | | | | 4. THE WEST STREETSCAPE DOES NOT MEET THE REQUIREMENTS | | | FOR PLACEMENT OR NUMBER OF THE REQUIRED STREET TREES | | | ALONG THE CURB. THE MEDIAN PLACEMENT OF TREES DO NOT | | | MEET THE INTENT OF PROVIDING TREE CANOPY OVER THE | | | PEDESTRIAN AREAS OF THE STREETSCAPE. | | | | | | | | | 5. FLORIDA FRIENDLY DESIGN OPTIONS POINTS CANNOT BE | | | COUNTED FOR 51% OR MORE NATIVE GROUNDCOVER, AS THEY ARE | | | ALL NON-NATIVE. POINTS CANNOT BE COUNTED FOR 51% OR | | | MORE NATIVE SHRUBS, AS THEY ARE ALL NON-NATIVE. | | | | | | 6. CORRECT IN THE PLANT LIST: NATCHEZ CRAPE MYRTLE IS | | | NOT FLORIDA NATIVE. AGAVE AMERICANA IS NOT FLORIDA | | | NATIVE. | | | | | | 7. SHOW LOCATIONS OF UTILITY LINES ON LANDSCAPE PLAN, | | | ALSO LOCATIONS OF VALVES AND BACKFLOW PREVENTERS AND | | | FPL TRANSFORMERS. SCREENING MUST BE PROVIDED. THERE ARE | | | CONFLICTS BETWEEN UTILITIES AND LANDSCAPING THAT WILL | | | HAVE TO BE RESOLVED. | | | | | | 8. PER SECTION 94-113, ADJUST LOCATIONS OF REQUIRED | | | STRUCTURAL SOIL TO ONLY SHOW UNDER HARDSCAPE ADJACENT | | | TO STREET TREES. AREA FOR STRUCTURAL SOIL AND PLANTING | | | AREA SHOULD BE APPROXIMATELY 14 FEET IN LENGTH AND 9 | | | FEET IN WIDTH RELATIVE TO THE BACK OF CURB. STRUCTURAL | | | SOIL DETAIL IS TO SHOW THE CONSTRUCTION CROSS SECTION | | | FOR DEPTH OF 36 INCHES, AND PLANTING SOIL IN THE | | | PLANTING AREA. DO NOT INCLUDE TREE GRATES UNLESS NEEDED | | | FOR ADA TRAVEL WIDTH. CORRECT THE DETAIL TO REFLECT | | | THIS. | | | | | | CONDITIONS OF APPROVAL | | | 1. PRIOR TO THE REMOVAL OR RELOCATION OF ANY TREES ON | | | THE PROPERTY, A TREE ALTERATION PERMIT SHALL BE | | | SUBMITTED, REVIEWED AND APPROVED BY THE DEVELOPMENT | | | SERVICES DEPARTMENT, PLANNING DIVISION. | | | 2. THE APPLICANT, SUCCESSORS AND ASSIGNS SHALL BE | | | RESPONSIBLE FOR THE PERMITTING AND INSTALLATION OF THE | | | STREET TREES AND RIGHT OF WAY LANDSCAPING AND | | | IRRIGATION APPROVED WITH THIS PETITION. | | | 3. THE APPLICANT, SUCCESSORS AND ASSIGNS SHALL BE | | | RESPONSIBLE FOR THE MAINTENANCE OF THE ROAD RIGHT OF | | | WAY LANDSCAPING AND IRRIGATION. THIS WILL BE THROUGH A | | | SEPARATE MAINTENANCE AGREEMENT WITH THE CITY. | | | |
|
|
| Review Stop |
PARK |
PARKING |
| Rev No |
1 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
|
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
POLICE |
POLICE |
| Rev No |
1 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
|
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
PW |
PUBLIC WORKS |
| Rev No |
2 |
Status |
F |
Date |
12-17-2021 |
|
|
Cont ID |
|
| Sent By |
|
Date |
12-17-2021 |
Time |
|
Rev Time |
0.00 |
| Received By |
|
Date |
12-17-2021 |
Time |
|
Sent To |
|
|
| Notes |
| 2021-12-17 14:25:38 | | | | PLEASE PROVIDE THE FOLLOWINGS: | | | 1- LOS (LEVEL OF SERVICE ANALYSIS) TO REFLECT THE SOLID | | | WASTE VOLUME PRODUCED ALONG WITH THE SIZE AND TYPE OF | | | THE CONTAINER (I.E. DUMPSTER/COMPACTOR) THAT WILL BE | | | UTILIZED THAT WILL BE UTILIZED FOR THE SANITATION | | | SERVICE. | | | 2- DETAILS FOR SANITATION SERVICE (I.E. SOLID WASTE | | | CONTAINER(S) TYPE, SIZE, ETC.). | | | 3- DESIGNATED LOCATION FOR THE BULK ITEM PICK UP | | | | | | MATT HEJAZI | | | DEPT. OF PUBLIC WORKS | | | [email protected] | | | 561-822-2045 |
|
|
| Review Stop |
PW |
PUBLIC WORKS |
| Rev No |
1 |
Status |
F |
Date |
12-30-2020 |
|
|
Cont ID |
|
| Sent By |
|
Date |
12-30-2020 |
Time |
|
Rev Time |
|
| Received By |
|
Date |
12-30-2020 |
Time |
|
Sent To |
|
|
| Notes |
| 2020-12-30 10:59:29 | | | | PLEASE PROVIDE THE FOLLOWINGS: | | | 1- LOS (LEVEL OF SERVICE ANALYSIS) TO REFLECT THE SOLID | | | WASTE VOLUME PRODUCED ALONG WITH THE SIZE AND TYPE OF | | | THE CONTAINER (I.E. DUMPSTER/COMPACTOR) THAT WILL BE | | | UTILIZED THAT WILL BE UTILIZED FOR THE SANITATION | | | SERVICE. | | | | | | 2- DETAILS FOR SANITATION SERVICE (I.E. SOLID WASTE | | | CONTAINER(S) TYPE, COLLECTION LOCATION, ETC.). | | | | | | 3- AUTO TURN (DYNAMIC ENVELOPE AND THE TIRES PATH) FOR | | | THE SANITATION SERVICE, FRONT LOADER TRUCK WITH THE | | | FOLLOWING SPECS: | | | - TRUCK LENGTH: 35 FT | | | - TRUCK WIDTH: 11 FT | | | - TURNING RADIUS: | | | - SAE TURNING RADIUS: 32.5 FT | | | - CURB-TO-CURB DIAMETER: 74 FT | | | - WALL-TO-WALL DIAMETER: 86.3 FT | | | | | | MATT HEJAZI | | | DEPT. OF PUBLIC WORKS | | | [email protected] | | | 561-822-2045 |
|
|
| Review Stop |
STORM |
STORMWATER |
| Rev No |
1 |
Status |
F |
Date |
01-14-2021 |
|
|
Cont ID |
|
| Sent By |
tward |
Date |
01-14-2021 |
Time |
13:36 |
Rev Time |
0.00 |
| Received By |
tward |
Date |
01-14-2021 |
Time |
13:38 |
Sent To |
|
|
| Notes |
| 2021-01-14 13:37:46 | THIS IS A CONCEPTUAL LEVEL REVIEW. CONSTRUCTION LEVEL | | | DETAILS, DESIGN CALCULATIONS AND THE POLLUTION | | | PREVENTION PLAN WILL BE REVIEWED AS PART OF THE | | | ENGINEERING DEVELOPMENT APPROVAL AND BUILDING PERMIT | | | APPLICATION PROCESSES. | | | | | | THE FOLLOWING COMMENTS MUST BE ADDRESSED PRIOR TO SITE | | | PLAN APPROVAL: | | | | | | | | | 1. VERIFY THE SIGN (POSITIVE/NEGATIVE) OF THE | | | CONVERSION FACTOR BETWEEN NAVD1988 AND NGVD1929 | | | VERTICAL DATUMS. | | | | | | 2. LIST THE WATER TABLE ELEVATION AS NAVD1988 WITH | | | NGVD1929 IN PARENTHESES. | | | | | | 3. THE LISTED WATER TABLE ELEVATION APPEARS TOO LOW | | | GIVEN THE DISTANCE TO THE LAKE WORTH LAGOON. FIELD | | | VERIFY THE WET SEASON WATER TABLE ELEVATION. (CAN BE | | | PROVIDED DURING ENGINEERING PERMIT APPLICATION). | | | | | | 4. PROVIDE TYPICAL CROSS SECTIONS FROM CENTERLINE OF | | | ADJACENT ROADS TO BUILDING FACE AND BETWEEN THE | | | BUILDING AND PARKING GARAGE. SHOW AND LABEL THE RIGHT | | | OF WAY LINES AND TYPICAL PROPOSED SLOPES. | | | | | | 5. HOW WILL BOTTOM FLOOR OF THE PARKING GARAGE DRAIN? | | | | | | 6. ADD THE DIFFERENT SPOT GRADE SYMBOLS TO THE SHEET | | | LEGEND OF SHEET CG101. | | | | | | 7. SHOW UTILITIES ON THE LANDSCAPE PLANS AND HARDSCAPE | | | PLANS. | | | | | | 8. SHOW ADA TACTILE SURFACES FOR CURB RAMPS ON THE | | | HARDSCAPE PLANS. | | | | | | 9. SHOW AND CALLOUT PERIMETER PLANTER AREAS ON THE | | | ENGINEERING PLANS. | | | | | | 10. PERIMETER PLANTER AREA AT NORTHWEST CORNER OF THE | | | SITE EXTENDS PAST THE CROSSWALK. | | | | | | 11. DRAINAGE SYSTEM TO BE DESIGNED TO MEET SFWMD ERP | | | CRITERIA. | | | | | | 12. NOTE BLEEDERS ARE NOT PERMITTED AS PART OF THE | | | CONTROL STRUCTURE USED TO SURCHARGE EXFILTRATION | | | TRENCHES. | | | | | | 13. SHOW MILL AND RESURFACING LIMITS FOR THE TRENCH | | | CUTS ON THE PGD PLAN. | | | | | | 14. INDICATE WHICH DRAINAGE STRUCTURES AND SIDES WILL | | | HAVE PRB'S. | | | | | | THE FOLLOWING COMMENTS MUST BE ADDRESSED PRIOR TO | | | ISSUANCE OF CONSTRUCTION AUTHORIZATION INCLUDING | | | BUILDING PERMITS AND ENGINEERING DEVELOPMENT APPROVAL. | | | | | | 1. AN ENGINEERING DEVELOPMENT APPROVAL APPLICATION MAY | | | BE REQUIRED FROM THE ENGINEERING SERVICES DEPARTMENT. | | | | | | 2. EROSION CONTROL PLAN AND DETAILS TO BE SUBMITTED | | | WITH THE ENGINEERING PERMIT APPLICATION. | | | | | | 3. A SFWMD ERP MAY BE REQUIRED. PROVIDE A COPY OF THE | | | PERMIT PRIOR TO STARTING CONSTRUCTION. | | | | | | 4. PROVIDE A COPY OF THE DRAINAGE CALCULATIONS WITH THE | | | ENGINEERING PERMIT APPLICATION. | | | | | | TRACY WARD, PE | | | SENIOR STORMWATER ENGINEER | | | ENGINEERING SERVICES DEPARTMENT | | | 561-494-1120 (O) | | | 561-351-0510 (M) | | | [email protected] | | | |
|
|
| Review Stop |
SURVEY |
SURVEYING |
| Rev No |
2 |
Status |
F |
Date |
05-11-2021 |
|
|
Cont ID |
|
| Sent By |
vnoel |
Date |
05-11-2021 |
Time |
10:07 |
Rev Time |
0.00 |
| Received By |
vnoel |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2021-05-11 11:14:56 | 1. NEED SIGN-OFFS FROM ALL UTILITIES FOR ANY | | | ENCROACHMENT INTO THE 14 FOOT UE. | | | 2. IF PROPOSED TO BE ABANDONED, APPLICATION NEEDS TO BE | | | MADE THROUGH ENGINEERING SERVICES AND SHOWN ON PLANS. | | | 3. 800 LEVEL ON SHEET A004 SHOWS ENCROACHMENT INTO FDOT | | | R/W. NEED WRITTEN APPROVAL AND/OR AERIAL ENCROACHMENT | | | EASEMENT FROM FDOT . | | | 4. DOMESTIC BACKFLOWS CANNOT BE LOCATED WITHIN | | | BUILDING. FIRE DEPT. WILL NEED TO APPROVE ANY FIRE LINE | | | BACKFLOWS WITHIN BUILDING. |
|
|
| Review Stop |
SURVEY |
SURVEYING |
| Rev No |
1 |
Status |
F |
Date |
01-12-2021 |
|
|
Cont ID |
|
| Sent By |
vnoel |
Date |
01-12-2021 |
Time |
07:36 |
Rev Time |
|
| Received By |
vnoel |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2021-01-12 07:51:12 | 1. SURVEY NEEDS TO BE SIGNED AND SEALED. | | | 2. WEST PROPERTY CORNERS ARE MISSING. | | | 3. ADD CONVERSION TO NGVD-29. | | | 4. TITLE SEARCH REPORT INFORMATION IS MISSING. | | | 5. PROPERTY WILL BE REQUIRED TO BE RE-PLATTED. | | | 6. LABEL DIXIE HWY. | | | 7. SURVEY SHOULD BE CLASSIFIED AS BOUNDARY & | | | TOPOGRAPHIC SURVEY. | | | 8. CHECK LEGAL DESCRIPTION FOR SPELLING. |
|
|
| Review Stop |
TRAFFIC |
TRAFFIC ENGINEERING |
| Rev No |
4 |
Status |
F |
Date |
12-22-2021 |
|
|
Cont ID |
|
| Sent By |
|
Date |
12-22-2021 |
Time |
|
Rev Time |
0.00 |
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2021-12-22 17:13:03 | TRAFFIC COMMENTS | | | 1) SATISFIED. PROVIDE COUNTY TPS LETTER | | | 2) SATISFIED. KEEP DRIVEWAY/WALKWAY LEVELED | | | 3) NOT SATISFIED. CONFIRM OR PROVIDE CAPACITY FOR | | | PUBLIC TRANSIT VEHICLES STOPS AND POTENTIALLY | | | ESTABLISHING A TRANSIT HUB WITHIN THE PROPOSED | | | DEVELOPMENT. | | | A. SHOWCASE THE PROPOSED RIDE SHARE AREA IN THE SITE | | | PLAN | | | B. SHOWCASE THE PROPOSED TRANSIT STOP(S) IN THE SITE | | | PLAN | | | C. PROVIDE A FIGURE SHOWCASING EXISTING TRANSIT | | | STOPS/FACILITIES WITHIN HALF A MILE FROM THE SITE | | | D. COORDINATE WITH PALM TRAN AND PROVIDE FEEDBACK | | | PERTAINING FUTURE AND/OR POTENTIAL TRANSIT ROUTES ALONG | | | QUADRILLE, OKEECHOBEE AND LAKEVIEW BLVD | | | 4) SATISFIED. CLARIFY THE DRIVEWAY FUNCTIONALITY ON THE | | | WEST SIDE OF THE DEVELOPMENT ON QUADRILLE BLVD, | | | SPECIFICALLY: | | | A. ARE VALET OPERATIONS CONDUCTED THERE? | | | B. IS IT FOR PICK-UP, DROP-OFF OR BOTH? | | | C. IS IT ACCESSIBLE TO ALL VEHICLES OR JUST | | | TAXI/UBER/LYFT? | | | 5) NOT SATISFIED. UNLESS MONITORING IS PROPOSED, THE | | | PICK-UP/DROP OFF AREA ON QUADRILLE SHOULD NOT BE | | | ACCESSIBLE TO ANY VEHICLE, EXCEPT FOR TRANSIT, | | | EMERGENCY AND SECURITY OPERATORS. PLEASE | | | CONFIRM/ACKOWLEDGE | | | 6) NOT SATISFIED. PROVIDE MORE DETAILS OF VALET | | | OPERATIONS | | | A. PROPOSED VALET DROP-OFF LOCATION IS NOT FEASIBLE, AS | | | THERE IS NO QUEUE STORAGE LENGTH PROVIDED. TWO QUEUED | | | VEHICLES WOULD BLOCK THE GARAGE ACCESS RAMP. | | | B. HIGHLIGHT/SHOWCASE VEHICLES' PATH FROM THE | | | SECOND-FLOOR DROP-OFF LOCATION TO THE VALET SPOTS ON | | | THE FIRST LEVEL | | | 7) NOT SATISFIED. PROVIDE A VALET SERVICE ANALYSIS | | | INCLUSIVE OF A NARRATIVE SHOWCASING OPERATIONAL DETAILS | | | (E.G. DAYS/HOURS OF OPERATION, NUMBER OF ATTENDANTS, | | | QUEUE ANALYSIS, SIGNAGE, ETC.) | | | 8) NOT SATISFIED. ARE THE TANDEM SPACES ON THE 7TH AND | | | 8TH FLOOR VALET ONLY? IF SO, THEY SHOULD BE MARKED AND | | | TABULATED ACCORDINGLY | | | 9) NOT SATISFIED. PROVIDE A PARKING TABLE INDICATING | | | THE TOTAL NUMBER OF REQUIRED AND PROVIDED PARKING | | | SPACES, WITH DETAILED BREAKDOWN OF EACH TYPE (I.E. | | | STANDARD, COMPACT, ADA, TANDEM, BICYCLE) | | | 10) SATISFIED. FEC RAILROAD CROSSING UPGRADE: PROVIDE | | | SIDEWALK CONNECTION ALONG OKEECHOBEE BLVD ON THE SOUTH | | | SIDE. PROVIDE FDOT PERMIT OR FEEDBACK ON THE MATTER. | | | 11) SATISFIED. GARAGE ACCESS RAMP ON THE SOUTH SIDE | | | SHOULD BE SET PERPENDICULAR TO OKEECHOBEE BLVD, IF BOTH | | | INBOUND/OUTBOUND MOVEMENTS ARE CONTEMPLATED | | | 12) SATISFIED. CONSIDER ONE-WAY OPERATIONS AT | | | DRIVEWAYS. FOR EXAMPLE: ENTRY ONLY IN THE SOUTH SIDE, | | | EXIT ONLY ON THE NORTH SIDE | | | 13) SATISFIED. PROVIDE TWO MICRO-MOBILITY DESIGNATED | | | AREAS NEARBY BUILDING ENTRANCES. WITH THE FOLLOWING | | | CHARACTERISTICS: | | | A. DIMENSIONS: 8' X 30' | | | B. CONDUIT (2" SCHEDULE 40 PVC) TO A POWER SOURCE WITH | | | AN ELECTRICAL PULL BOX (240V CIRCUIT) | | | 14) SATISFIED. COORDINATE WITH PARKING DEPARTMENT FOR | | | PARKING LOSS COMPENSATION/MITIGATION | | | 15) NOT SATISFIED. PROVIDE AUTOTURN ANALYSIS FOR | | | GARBAGE AND SERVICE VEHICLES. | | | 16) NOT SATISFIED. PROPOSED DRIVEWAYS' WIDTH IS | | | EXCESSIVE AND UNSAFE. PROVIDE A MINIMUM OF 5 FEET WIDE | | | PEDESTRIAN REFUGE ISLAND BETWEEN SERVICE DRIVE AND | | | GARAGE ACCESS/ENTRY | | | 17) NOT SATISFIED. PROVIDE BICYCLE RACKS NEARBY | | | BUILDING ENTRANCE(S) AND DISTINCTIVELY MARK THEM ON | | | SITE PLANS | | | 18) NOT SATISFIED. UNLESS AUTOTURN ANALYSIS PROVES | | | PARKING MANEUVERABILITY, REMOVE THE LAST TWO PARKING | | | STALLS AT THE DEAD-END ON THE NINTH FLOOR OF THE | | | GARAGE. | | | 19) PARTIALLY SATISFIED. COORDINATE WITH PLANNING | | | DEPARTMENT FOR TDM MITIGATION MEASUREMENTS. PROVIDEA | | | FINAL AND MUTUALLY AGREED LIST OF TDM MEASUREMENTS | | | 20) NOT SATISFIED. HOW IS ACCESS TO THE GARAGE SERVICE | | | DRIVE INDICATED SIGNAGE-WISE AND HOW IS IT CONTROLLED? | | | |
|
|
| Review Stop |
TRAFFIC |
TRAFFIC ENGINEERING |
| Rev No |
3 |
Status |
F |
Date |
05-05-2021 |
|
|
Cont ID |
|
| Sent By |
|
Date |
05-05-2021 |
Time |
|
Rev Time |
0.00 |
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2021-05-05 13:38:20 | TRAFFIC COMMENTS | | | 1) SATISFIED. PROVIDE COUNTY TPS LETTER | | | 2) SATISFIED. KEEP DRIVEWAY/WALKWAY LEVELED | | | 3) NOT SATISFIED. CONFIRM OR PROVIDE CAPACITY FOR | | | PUBLIC TRANSIT VEHICLES STOPS AND POTENTIALLY | | | ESTABLISHING A TRANSIT HUB WITHIN THE PROPOSED | | | DEVELOPMENT. | | | A. SHOWCASE THE PROPOSED RIDE SHARE AREA IN THE SITE | | | PLAN | | | B. SHOWCASE THE PROPOSED TRANSIT STOP(S) IN THE SITE | | | PLAN | | | C. PROVIDE A FIGURE SHOWCASING EXISTING TRANSIT | | | STOPS/FACILITIES WITHIN HALF A MILE FROM THE SITE | | | D. COORDINATE WITH PALM TRAN AND PROVIDE FEEDBACK | | | PERTAINING FUTURE AND/OR POTENTIAL TRANSIT ROUTES ALONG | | | QUADRILLE, OKEECHOBEE AND LAKEVIEW BLVD | | | 4) SATISFIED. CLARIFY THE DRIVEWAY FUNCTIONALITY ON THE | | | WEST SIDE OF THE DEVELOPMENT ON QUADRILLE BLVD, | | | SPECIFICALLY: | | | A. ARE VALET OPERATIONS CONDUCTED THERE? | | | B. IS IT FOR PICK-UP, DROP-OFF OR BOTH? | | | C. IS IT ACCESSIBLE TO ALL VEHICLES OR JUST | | | TAXI/UBER/LYFT? | | | 5) NOT SATISFIED. UNLESS MONITORING IS PROPOSED, THE | | | PICK-UP/DROP OFF AREA ON QUADRILLE SHOULD NOT BE | | | ACCESSIBLE TO ANY VEHICLE, EXCEPT FOR TRANSIT, | | | EMERGENCY AND SECURITY OPERATORS. | | | 6) NOT SATISFIED. PROVIDE MORE DETAILS OF VALET | | | OPERATIONS | | | A. PROPOSED VALET DROP-OFF LOCATION IS NOT FEASIBLE, AS | | | THERE IS NO QUEUE STORAGE LENGTH PROVIDED. TWO QUEUED | | | VEHICLES WOULD BLOCK THE GARAGE ACCESS RAMP. | | | B. HIGHLIGHT/SHOWCASE VEHICLES? PATH FROM THE SECOND | | | FLOOR DROP-OFF LOCATION TO THE VALET SPOTS ON THE FIRST | | | LEVEL | | | 7) NOT SATISFIED. FEC RAILROAD CROSSING UPGRADE: | | | PROVIDE SIDEWALK CONNECTION ALONG OKEECHOBEE BLVD ON | | | THE SOUTH SIDE. PROVIDE FDOT PERMIT OR FEEDBACK ON THE | | | MATTER. | | | 8) SATISFIED. GARAGE ACCESS RAMP ON THE SOUTH SIDE | | | SHOULD BE SET PERPENDICULAR TO OKEECHOBEE BLVD, IF BOTH | | | INBOUND/OUTBOUND MOVEMENTS ARE CONTEMPLATED | | | 9) SATISFIED. CONSIDER ONE-WAY OPERATIONS AT DRIVEWAYS. | | | FOR EXAMPLE: ENTRY ONLY IN THE SOUTH SIDE, EXIT ONLY ON | | | THE NORTH SIDE | | | 10) SATISFIED. PROVIDE TWO MICRO-MOBILITY DESIGNATED | | | AREAS NEARBY BUILDING ENTRANCES. WITH THE FOLLOWING | | | CHARACTERISTICS: | | | A. DIMENSIONS: 8 X 20 FEET | | | B. CONDUIT (2 FEET SCHEDULE 40 PVC) TO A POWER SOURCE | | | WITH AN ELECTRICAL PULL BOX (240V CIRCUIT) | | | 11) SATISFIED. COORDINATE WITH PARKING DEPARTMENT FOR | | | PARKING LOSS COMPENSATION/MITIGATION | | | 12) NOT SATISFIED. PROVIDE AUTOTURN ANALYSIS FOR | | | GARBAGE AND SERVICE VEHICLES. | | | 13) NOT SATISFIED. PROPOSED DRIVEWAYS? WIDTH IS | | | EXCESSIVE AND UNSAFE. PROVIDE A MINIMUM OF 5 FEET WIDE | | | PEDESTRIAN REFUGE ISLAND BETWEEN SERVICE DRIVE AND | | | GARAGE ACCESS/ENTRY | | | 14) NOT SATISFIED. PROVIDE BICYCLE RACKS NEARBY | | | BUILDING ENTRANCE(S) AND DISTINCTIVELY MARK THEM ON | | | SITE PLANS | | | 15) NOT SATISFIED. UNLESS AUTOTURN ANALYSIS PROVES | | | PARKING MANEUVERABILITY, REMOVE THE LAST TWO PARKING | | | STALLS AT THE DEAD-END ON THE NINTH FLOOR OF THE | | | GARAGE. | | | 16) PARTIALLY SATISFIED. COORDINATE WITH PLANNING | | | DEPARTMENT FOR TDM MITIGATION MEASUREMENTS. A FINAL AND | | | MUTUALLY AGREED LIST OF TDM MEASUREMENTS SHALL BE | | | PROVIDED IN ORDER TO PASS THE TRAFFIC ENGINEERING | | | REVIEW. | | | | | | VALERIO ORICCHIO | | | CITY TRANSPORTATION ENGINEER | | | 561-494-1092 | | | [email protected] | | | |
|
|
| Review Stop |
TRAFFIC |
TRAFFIC ENGINEERING |
| Rev No |
2 |
Status |
F |
Date |
03-31-2021 |
|
|
Cont ID |
|
| Sent By |
|
Date |
03-31-2021 |
Time |
|
Rev Time |
0.00 |
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2021-03-31 13:18:32 | | | | | | | VALERIO ORICCHIO | | | CITY TRANSPORTATION ENGINEER | | | 561-494-1092 | | | [email protected] | | | |
|
|
| Review Stop |
TRAFFIC |
TRAFFIC ENGINEERING |
| Rev No |
1 |
Status |
F |
Date |
01-14-2021 |
|
|
Cont ID |
|
| Sent By |
|
Date |
01-14-2021 |
Time |
|
Rev Time |
|
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2021-01-14 11:45:07 | TRAFFIC COMMENTS | | | | | | 1) PROVIDE COUNTY TPS LETTER | | | 2) KEEP DRIVEWAY/WALKWAY LEVELED | | | 3) CONFIRM OR PROVIDE CAPACITY FOR PUBLIC TRANSIT | | | VEHICLES STOPS AND POTENTIALLY ESTABLISHING A TRANSIT | | | HUB WITHIN THE PROPOSED DEVELOPMENT | | | 4) CLARIFY THE DRIVEWAY FUNCTIONALITY ON THE WEST SIDE | | | OF THE DEVELOPMENT ON QUADRILLE BLVD, SPECIFICALLY: | | | 4A. ARE VALET OPERATIONS CONDUCTED THERE? | | | 4B. IS IT FOR PICK-UP, DROP-OFF OR BOTH? | | | 4C. IS IT ACCESSIBLE TO ALL VEHICLES OR JUST | | | TAXI/UBER/LYFT? | | | 5) PROVIDE MORE DETAILS OF VALET OPERATIONS, IF ANY | | | 6) FEC RAILROAD CROSSING UPGRADE: PROVIDE SIDEWALK | | | CONNECTION ALONG OKEECHOBEE BLVD ON THE SOUTH SIDE | | | 7) GARAGE ACCESS RAMP ON THE SOUTH SIDE SHOULD BE SET | | | PERPENDICULAR TO OKEECHOBEE BLVD, IF BOTH | | | INBOUND/OUTBOUND MOVEMENTS ARE CONTEMPLATED | | | 8) CONSIDER ONE-WAY OPERATIONS AT DRIVEWAYS. FOR | | | EXAMPLE: ENTRY ONLY IN THE SOUTH SIDE, EXIT ONLY ON THE | | | NORTH SIDE | | | 9) PROVIDE TWO MICRO-MOBILITY DESIGNATED AREAS NEARBY | | | BUILDING ENTRANCES. WITH THE FOLLOWING CHARACTERISTICS: | | | 9A. DIMENSIONS: 8' X 20' | | | 9B. CONDUIT (2' SCHEDULE 40 PVC) TO A POWER SOURCE WITH | | | AN ELECTRICAL PULL BOX (240V CIRCUIT) | | | 10) CORDINATE WITH PARKING DEPARTMENT FOR PARKING LOSS | | | COMPENSATION/MITIGATION | | | 11) CORDINATE WITH PLANNING DEPARTMENT FOR TDM | | | MITIGATION MEASUREMENTS | | | | | | VALERIO ORICCHIO | | | CITY TRANSPORTATION ENGINEER | | | 561-494-1092 | | | [email protected] | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
4 |
Status |
F |
Date |
12-21-2021 |
|
|
Cont ID |
|
| Sent By |
aaponte |
Date |
12-21-2021 |
Time |
12:32 |
Rev Time |
0.00 |
| Received By |
aaponte |
Date |
12-16-2021 |
Time |
12:32 |
Sent To |
|
|
| Notes |
| 2021-12-21 12:43:04 | 1. TREES ALONG LAKEVIEW AVE AND OKEECHOBEE AVE SHALL BE | | | MOVED OUTSIDE THE PARKING GARAGE LINE OF SIGHT. A | | | MINIMUM OF 12 FEET MULTIPURPOSE PATH SHALL BE | | | MAINTAINED. SOME ADJUSTMENT WILL BE NEEDED ON THE | | | PROPOSED LANDSCAPE DESIGN ADJACENT TO THE OFFICE TOWER | | | TO ACCOMMODATE THE LINE OF TREES. | | | 2. SIDEWALK LEVEL SHALL BE MAINTAINED ACROSS ALL THE | | | DRIVEWAYS. PLEASE AJUST THE CIVIL DESIGN TO ENSURE THE | | | GRADE ELEVATION IS MAINTAINED. | | | 3. PARKING GATE IS LOCATED AT THE 2ND LEVEL. WHAT IS | | | THE PROPOSAL FOR RETAIL AND VALET PARKING? STAFF | | | RECOMMENDS THE GATE TO BE INSTALLED AT THE 3RD LEVEL TO | | | ALLOW PARKING FOR CUSTOMERS OR EXPLAIN INTENDED | | | OPERATION. | | | 4. HOW IS THE 2ND LEVEL OFFICE ALONG THE PASEO ACCESSED | | | FROM THE ELEVATOR? PLEASE VERIFY COMPLIANCE WITH | | | EMERGENCY EXIT REQUIREMENTS. | | | 5. VALET OPERATION DOES NOT PROVIDE A BY-PASS LANE | | | CREATING A POSSIBLE BACK UP FOR CARS. SOME REDESIGN MAY | | | BE NEEDED. | | | 6. ALL TANDEM PARKING SPACES SHALL BE MANAGED BY THE | | | VALET OPERATION. PLEASE LABEL ACCORDINGLY. | | | 7. PLEASE LABEL THE LOCATION OF ALL CAR SHARE AND RIDE | | | SHARE SPACES REQUIRED BY THE TDM STRATEGIES. | | | 8. PLEASE CONFIRM COMPLIANCE WITH OPEN SPACE | | | REQUIREMENTS FOR VEGETATION AND TREE CANOPY. THE | | | CALCULATION CAN BE DONE OVER A MINIMUM AREA TO COMPLY | | | WITH THE PERCENTAGE AND NOT THE LARGER OPEN SPACE | | | PROVIDED. (SEE LANDSCAPE COMMENTS) | | | 9. BUILDING FOOTPRINT PRIVIDED ON SHEET A004 DOES NOT | | | MATCH THE WAIVER REQUEST, PLEASE CONFIRM WHAT IS THE | | | CORRECT NUMBER. | | | 10. PLEASE PROVIDE AN EXHIBIT TO CALCULATE THE PROVIDED | | | ACTIVE USES AT GROUND FLOOR AND ABOVE TO CONFIRM WAIVER | | | REQUEST. | | | FOR ADDITIONAL INFORMATION PLEASE CONTACT ANA MARIA | | | APONTE AT 561-822-1439. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
F |
Date |
07-01-2021 |
|
|
Cont ID |
|
| Sent By |
aaponte |
Date |
07-01-2021 |
Time |
11:59 |
Rev Time |
0.00 |
| Received By |
aaponte |
Date |
06-02-2021 |
Time |
13:02 |
Sent To |
|
|
| Notes |
| 2021-07-01 12:00:14 | COMMENTS TO 6/2/21 SET | | | 1. NOT SATISFIED. APPLICANT NEEDS TO SUBMIT A REPORT | | | WITH THE REQUIRED CALCULATIONS FOR THE CONVERSION OF | | | USES NECESSARY TO ACCOUNT FOR THE OFFICE SQUARE FOOTAGE | | | ABOVE THE AVAILABLE POOL. PREVIOUS COMMENT: THE PROJECT | | | EXCEEDS THE MAXIMUM SQUARE FOOTAGE CURRENTLY ALLOCATED | | | FOR OFFICE IN THE DRI CAPACITY TABLE. BASED ON THE | | | LATEST NUMBERS, A CONVERSION FROM OTHER CATEGORY WOULD | | | BE NEEDED TO ALLOW 62,833 SF OF ADDITIONAL OFFICE | | | SPACE. PLEASE SUBMIT CONVERSION ANALYSIS ACCORDING TO | | | ORDINANCE 4412-12.-PREVIOUS COMMENT: PLEASE PROVIDE A | | | GROSS SQUARE FOOTAGE CALCULATION FOR EACH USE TO | | | DETERMINE THE NEED FOR CONVERSION CAPACITY FROM THE | | | CITYPLACE DRI. CURRENTLY THERE IS ONLY 383,429 SF OF | | | OFFICE SPACE, AND 32,337 SF OR RETAIL AVAILABLE IN THE | | | POOL. IT SEEMS THE GBA OF PROPOSED OFFICE MAY EXCEED | | | THE AVAILABLE SF NECESSITATING A SF CONVERSION. | | | 2. SATISFIED.- PLEASE REVIEW ORDINANCE NO. 4412-12 AND | | | PROVIDE CONFIRMATION OF COMPLIANCE FOR ALL APPLICABLE | | | ITEMS. | | | 3. PARTIALLY SATISFIED. PASSAGEWAY SHALL COMPLY WITH | | | PUBLIC OPEN SPACE DESIGN STANDARDS IN ORDER TO BE | | | COUNTED AS ACTIVE USES, SEATING, VEGETATION AND TREE | | | CANOPY SHALL BE INCLUDED IN THE PASSAGE WAY. PREVIOUS | | | COMMENTS: STAFF UNDERSTAND WAIVERS ARE REQUESTED. | | | PLEASE PROVIDE SCHEMATIC DRAWING INDICATING THE | | | COMPLIANCE AT GROUND FLOOR AND THE WAIVERS REQUESTED | | | FOR FLOORS 2ND-5TH. IF THE AREA OF THE PASEO MEETS THE | | | PUBLIC OPEN SPACE REQUIREMENTS, IT CAN BE COUNTED AS | | | ACTIVE USE AS IT IS ADJACENT TO ACTIVE USES ON BOTH | | | SIDES.- PREVIOUS COMMENT: PLEASE PROVIDE GRAPHIC | | | INFORMATION TO DEMONSTRATE COMPLIANCE WITH THE ACTIVE | | | USE REQUIREMENTS. | | | 4. NOT SATISFIED. SOME SUGGESTIONS TO REDUCE THE NUMBER | | | OF WAIVERS REQUESTED: | | | A. AS IT SEEMS THE PROPOSED VALET PARKING SPACES ON THE | | | GROUND FLOOR ARE NOT USABLE (DUE TO CIRCULATION | | | PATTERNS) THE GROUND FLOOR ACTIVE USE ALONG DIXIE HWAY | | | COULD BE MODIFIED TO MEET THE MINIMUM DEPTH REQUIRED. | | | B. SATISFIED WITH HORIZONTAL VARIATION PROVIDED IN THE | | | GARAGE. PREVIOUS COMMENT: PLANAR BREAKS COULD BE | | | MEASURED HORIZONTALLY WITH THE VARIATION ON THE | | | BUILDING PLANE OF EACH PARKING LEVEL. | | | C. NOT SATISFIED: PLEASE PROVIDE ALTERNATIVE LOCATION | | | FOR THE REQUIRED TREES. PREVIOUS COMMENT: CONSIDERING | | | THE CANOPY AT THE MAIN ENTRANCE IS AT 33? IN HEIGHT, | | | TREES MAY BE INSTALLED ALONG THE CURB TO COMPLY WITH | | | TREE PLANTING REQUIREMENT. | | | PREVIOUS COMMENT: PROJECT IS REQUESTING 22 DIFFERENT | | | WAIVERS FROM REGULATIONS. PLEASE FURTHER STUDY OPTIONS | | | TO COMPLY WITH CODE REQUIREMENTS OR REDUCE THE WAIVER | | | REQUEST. SOME OF THE WAIVERS THAT CAN BE REDUCED | | | INCLUDE: | | | A. SATISFIED-PORTE COCHERE. CONSIDERING THE DROP-OFF | | | AREA ON QUADRILLE CANNOT MEET THE PORTE COCHERE | | | REQUIREMENTS STAFF RECOMMENDS UTILIZING A REGULAR | | | ON-STREET DROP-OFF. | | | B. SATISFIED-TOWER AND GARAGE SEPARATION ARE NOT | | | APPLICABLE TO THIS DISTRICT. | | | 5. SATISFIED. WAIVER REQUESTED. PLEASE PROVIDE SOME | | | SECTIONS TO INDICATE THE RELATION BETWEEN THE OFFICE | | | TOWER LEVELS AND THE GARAGE LEVELS. IF THE OFFICE | | | LEVELS ARE USED, GARAGE LEVELS 8,9 AND 10 SEEM TO | | | EXCEED TO MAXIMUM FOOTPRINT (TOWER LEVELS 6 AND 7).THE | | | WAIVER REQUEST SHOULD BE FOR THOSE TWO FLOORS TO EXCEED | | | THE MAXIMUM 55% BUILDING FOOTPRINT ALLOWED? PREVIOUS | | | COMMENT: PROJECT EXCEEDS THE MAXIMUM BUILDING FOOTPRINT | | | ALLOWED AT THE 6TH AND 7TH STORY (55%) AND ABOVE 8TH | | | STORY (50%) DUE TO THE PARKING GOING UP 10 STORIES. | | | JUSTIFICATION LIST THE WAIVER REQUEST TO EXCEED THE | | | MAXIMUM BUILDING FOOTPRINT FROM 6TH TO 24TH FLOOR. | | | PLEASE CLARIFY WHAT IS THE BUILDING FOOTPRINT PROVIDED | | | ABOVE THE 10TH LEVEL. THE PROJECT IS ALLOWED TO EXCEED | | | MAXIMUM BUILDING FOOTPRINTS ABOVE THE 5TH FLOOR, BUT IN | | | COMPLIANCE WITH THE CONDITIONAL SETBACK, WHICH IS NOT | | | PROVIDED AT THIS POINT. | | | 6. SATISFIED- PLEASE INDICATE LOCATION OF 20 | | | CARPOOL/VANPOOL AND 10 CAR SHARE STATION PROPOSED AS | | | PART OF THE TDM STRATEGIES TO REACH MAXIMUM PARKING | | | ALLOWED. PROPOSED PARKING EXCEEDS THE MAXIMUM ALLOWED. | | | MAXIMUM PARKING ALLOWED FOR THE PROJECT IS: | | | SOFT MAXIMUM = 398,590 SF AT1.5/1,000 = 598 SPACES | | | ADDITIONAL .75/1,000 WITH CONTRIBUTION TO TRANSIT = 299 | | | SPACES | | | ADDITIONAL WITH TDM STRATEGIES = 299 SPACES | | | TOTAL ALLOWED = 1,196 SPACES ? PARKING PROPOSED ON | | | 6/2/21 SUBMITTAL IS 1,195 | | | PARKING PROPOSES ON APRIL 23, 21 VERSION = 1,213 SPACES | | | TO INCREASE FROM THE SOFT MAXIMUM THE PROJECT CAN: | | | A. CONTRIBUTE TO THE TRANSIT OPERATION FUND (EXACT | | | AMOUNT TO BE CALCULATED). THAT WILL ALLOW 299 | | | ADDITIONAL PARKING SPACES. | | | B. THE ADDITIONAL SPACES REQUESTED UP TO THE HARD | | | MAXIMUM WOULD REQUIRE THE IMPLEMENTATION OF TDM | | | STRATEGIES. PLEASE IDENTIFY WHICH TDM STRATEGIES THE | | | PROJECT IS GOING TO IMPLEMENT. | | | | | | 7. NOT SATISFIED . AT LEAST CURB CUT ON LAKEVIEW CAN BE | | | REDUCED TO 12? WIDE TRAVEL LANES. WAIVER REQUESTED. | | | REFUGE AREA MENTIONED IN THE RESPONSE LETTER IS NOT | | | SHOWN IN THE DRAWINGS. PREVIOUS COMMENT: PROPOSED CURB | | | CUT EXCEEDS THE MAXIMUM 25 FEET ALLOWED. FURTHER | | | DISCUSSION NECESSARY TO DETERMINE IF THE SERVICE DRIVE | | | CAN BE REDUCED, OR IF THERE ARE ANY MEASURES TO | | | MITIGATE THE IMPACT ON PEDESTRIANS. | | | 8. SATISFIED. CONDITION TO BE INCLUDED IN APPROVAL- | | | SIDEWALK ELEVATION SHALL BE MAINTAINED ACROSS THE | | | DRIVEWAY. | | | 9. SATISFIED- FDOT REQUIRES A PUBLIC PURPOSE LEASE | | | REQUEST FOR THE DROP-OFF AREA INITIATED BY CITY OR CRA. | | | PLEASE PROVIDE PRE-APPROVAL LETTER FROM FDOT TO CONFIRM | | | THEY WILL ACCEPT THE DROP OFF AREA ON QUADRILLE BLVD | | | AND THE LOCATION OF THE CURB CUTS.-PREVIOUS COMMENT: | | | TPS LETTER FROM COUNTY MENTIONS THE POSSIBLE NEED FOR | | | DECELERATION LANES TO ACCESS GARAGE. PLEASE PROVIDE A | | | PRE-DETERMINATION LETTER FROM FDOT CONFIRMING THE | | | AGENCY APPROVAL FOR THE PROPOSED SIDE PLAN (DRIVEWAYS, | | | TREES ETC.) | | | 10. SATISFIED. PLEASE PROVIDE NARRATIVE ON THE CURB | | | SIDE MANAGEMENT OF ON-STREET DROP OFF/PICK UP AREA | | | PROPOSED ON QUADRILLE BLVD.- PREVIOUS COMMENT: PLEASE | | | PROVIDE FOR A CURB SIDE MANAGEMENT PLAN AND A FREIGHT | | | DELIVERY MANAGEMENT PLAN. | | | 11. SATISFIED. PROPOSED VALET LOCATION IS NOT | | | FUNCTIONAL, THE VALET OPERATION IS BLOCKING THE TRAVEL | | | LANES. A SEPARATE AREA FOR STACKING IS NEEDED. PLEASE | | | INDICATE THE TRAVEL PATHS FOR CARS RECEIVED AT THE 2ND | | | FLOOR VALET TO THE GROUND FLOOR VALET PARKING AREA. | | | VALET CARS SHOULD NOT CIRCULATE IN THE PUBLIC ROW. ? | | | PREVIOUS COMMENT: PLEASE PROVIDE INFORMATION REGARDING | | | THE OPERATION OF THE VALET SERVICE FOR THE BUILDING. | | | PLEASE IDENTIFY THE LOCATION OF THE VALET PARKING | | | DROP-OFF /PICK UP AREA INSIDE THE GARAGE. | | | 12. TO BE INCLUDED AS A CONDITON OF APPROVAL- DUE TO | | | THE PROPOSAL TO INCLUDE TANDEM PARKING SPACES, VALET | | | SERVICE WILL BE REQUIRED FOR THE PROJECT. A RESTRICTIVE | | | COVENANT WILL BE REQUIRED FOR THE PROJECT. | | | | | | 13. STAFF STILL RECOMMENDS MORE REALISTIC RENDERINGS BE | | | PROVIDED FOR STAFF EVALUATION AND PUBLIC MEETINGS. | | | STAFF RECOMMENDS MORE REALISTIC RENDERINGS FOR THE PB | | | AND CITY COMMISSION MEETING. CAN THE CONCRETE PARAPET | | | THAT CREATES THE ILLUSION OF SLAB THICKNESS BE TALLER | | | TO FURTHER SCREEN THE CARS FROM VIEW? WHAT ABOUT SOME | | | VEGETATION IN SOME OF THE SLAB PROJECTIONS THAT | | | COMPLEMENT THE ART INSTALLATION AND HELP SCREEN THE | | | CARS?? PREVIOUS COMMENT: ADDITIONAL INFORMATION SHALL | | | BE PROVIDED REGARDING THE PROPOSED DESIGN OF THE | | | PARKING GARAGE. STAFF RECOMMENDS APPLICANT TO PROVIDE | | | DETAILED SECTIONS TO FULLY EXPLAIN THE SPECIAL DESIGN | | | OF THE GARAGE SLABS THAT WILL JUSTIFY THE LACK OF | | | ACTIVE USES. REALISTIC RENDERING IMAGES ARE ALSO | | | RECOMMENDED TO FULLY DEPICT THE IMAGE OF THE GARAGE AND | | | ALLOW A COMPLETE UNDERSTANDING OF THE GARAGE IMPACT ON | | | THE SURROUNDING. RENDERINGS SHALL BE PROVIDED FROM ALL | | | THE DIFFERENT VIEW POINTS OF THE GARAGE (DIXIE, | | | LAKEVIEW, OKEECHOBEE) AND FROM STREET LEVEL PERSPECTIVE | | | AS WELL AS FROM UPPER LEVELS FROM SURROUNDING | | | BUILDINGS. | | | PLANS INDICATE SOME OF THE PARKING SPACES AT THE EDGE | | | OF THE SLAB, ARE THE CARS VISIBLE FROM OUTSIDE? | | | 14. NOT SATISFIED. SOME OF THE GARAGE SLABS ENCROACH | | | INTO THE MINIMUM REQUIRED SETBACKS. SECTION IN A513 | | | DOES NOT SEEM TO MATCH FLOOR PLANS BUT SEEMS TO | | | INDICATE SOME ADDITIONAL SETBACK ABOVE FLOOR 6TH BEYOND | | | THE MINIMUM REQUIRED. PLEASE INDICATE THE MINIMUM | | | SETBACK LINE AND THE CONDITIONAL SETBACK FOR PARKING | | | USES TO DETERMINE THE EXTENT OF THE WAIVER IN EACH | | | PARKING LEVEL. PREVIOUS COMMENT: PLEASE INDICATE THE | | | MINIMUM SETBACK IN THE GARAGE SECTIONS TO IDENTIFY THE | | | EXTEND OF THE ENCROACHMENTS INDICATED IN THE FLOOR | | | PLANS. ARE THE ENCROACHMENTS PROPOSED ARCHITECTURAL | | | FEATURES? | | | 15. NOT SATISFIED. IF THE PROJECT INTENDS TO ASK FOR A | | | WAIVER, THE REQUIRED TREES SHALL BE LOCATED ON OTHER | | | PARTS OF THE PROJECT OR A MITIGATION FEE PAID INTO THE | | | TREE FUND. SOME ADDITIONAL TREES CAN BE INSTALLED NORTH | | | AND SOUTH OF THE CANOPY TO BRING THE PROJECT CLOSER | | | INTO COMPLIANCE WITH THE REQUIREMENT. PLEASE SUGGEST | | | WHERE THE REMAINING TREES CAN BE LOCATION AROUND THE | | | PROJECT. PREVIOUS COMMENT: STREET TREES ARE REQUIRED | | | ALONG THE QUADRILLE BOULEVARD FRONTAGE EVERY 30 FEET. | | | 16. SATISFIED. SIDEWALK ALONG THE QUADRILLE FRONTAGE IS | | | 10 FEET AT ITS NARROWEST POINT. PREVIOUS COMMENT: | | | SIDEWALK ALONG QUADRILLE BOULEVARD BY THE BUILDING | | | ENTRANCE SHALL BE A MINIMUM OF 8 FEET IN WIDTH. | | | 17. SATISFIED. PLEASE PROVIDE A FA?ADE DETAIL DEPICTING | | | THE TREATMENT OF THE FA?ADE TO ACCOMMODATE THE UTILITY | | | ELEMENTS. ALSO PLEASE CLARIFY HOW IS THE ACCESS TO THE | | | FIRE BACKFLOW. - PREVIOUS COMMENT: ALL BACKFLOW | | | PREVENTORS AND ABOVE GROUND UTILITY CONNECTIONS AT THE | | | GROUND LEVEL NEED TO BE SCREENED FROM VIEW. FURTHER | | | DISCUSSION IS NECESSARY TO DETERMINE THE MOST | | | APPROPRIATE LOCATION. LANDSCAPE DRAWINGS AND SITE PLAN | | | DRAWINGS SHALL REFLECT THE PROPOSED LOCATION OF SUCH | | | EQUIPMENT. | | | 18. SATISFIED. SIGNAGE TO BE SUBMITTED - A COMPLETE | | | SIGNAGE PACKET SHALL BE SUBMITTED FOR APPROVAL AS PART | | | OF THE LEVEL III SITE PLAN APPROVAL PROCESS BY THE CITY | | | COMMISSION. | | | 19. SATISFIED. PLEASE CONFIRM THAT THE DESIGNATED 798 | | | SF ROOM IS SUFFICIENT TO ACCOMMODATE THE 120 BIKE | | | PARKING SPACES. PREVIOUS COMMENT. BIKE PARKING REQUIRED | | | IS 120 SPACES. - PREVIOUS COMMENT: THE BIKE STORAGE | | | INDICATED ON THE GROUND FLOOR ALONG OKEECHOBEE BLVD | | | DOES NOT SEEM ENOUGH TO ACCOMMODATE THE 120 BIKE SPACES | | | REQUIRED FOR THE PROJECT (1/10 PARKING SPACES) | | | 20. NOT SATISFIED. TO BE INCLUDED AS A CONDITION OF | | | APPROVAL. SHOWERS MAY BE DISTRIBUTED THROUGHOUT THE | | | BUILDING, BUT IT SHALL BE ENSURED THAT ALL TENANTS HAVE | | | ACCESS TO A SHOWER FACILITY (13 SHOWERS REQUIRED). | | | SHEET A112 WAS NOT INCLUDED IN SUBMITTED SET. BASED ON | | | THE 382,211 SF OF NET OFFICE SPACE, THE PROJECT IS | | | REQUIRED TO PROVIDE 13 SHOWERS AND CHANGING FACILITIES. | | | SHOWERS SHALL BE IN AREAS ACCESSIBLE TO ALL TENANTS. | | | PLEASE INDICATE PRELIMINARY LOCATION FOR SITE PLAN | | | APPROVAL PROCESS- PREVIOUS COMMENT: PLEASE INDICATE THE | | | LOCATION OF THE SHOWER AND CHANGING ROOMS REQUIRED FOR | | | THE PROJECT (1 SHOWER AND CHANGING /30,000 SF OF | | | OFFICE). | | | 21. SATISFIED. PLEASE INCLUDE A NOTE CALLING OUT THE | | | NON-REFLECTIVE NATURE OF THE GLASS IN THE FA?ADE. - | | | PLEASE CONFIRM THE PROPOSED GLASS IS NOT A REFLECTIVE | | | GLASS TO CAUSE IMPACT OF DRIVERS. | | | 22. NOT SATISFIED. PLEASE LAY OUT THE LINE OF SIGHT | | | MEETING THE FDOT REQUIREMENTS TO CONFIRM THE LOCATION | | | OF THE TREES INDICATED IN THE DRAWINGS MEET FDOT | | | REQUIREMENTS. PLEASE OBTAIN A PRE-APPROVAL LETTER FROM | | | FDOT TO CONFIRM THEY WILL ALLOW THE PROPOSED PLACEMENT | | | OF TREES ALONG THE CURB LINE. - PLEASE CONFIRM FDOT HAS | | | APPROVED THE LOCATIONS OF THE PROPOSED TREES ALONG THE | | | CURB. | | | 23. PARTIALLY SATISFIED. WHAT ARE THE FDOT STANDARDS | | | FOR A PEDESTRIAN CROSSING? PEDESTRIAN CROSSINGS SHOULD | | | HAVE THERMOPLASTIC ZEBRA PATTERN AND ADA RAMPS. ? | | | PREVIOUS COMMENT: PLEASE PROVIDE INFORMATION TO CONFIRM | | | COMPLIANCE WITH THE PROVISION OF PEDESTRIAN CROSSINGS | | | AT ALL INTERSECTIONS. | | | 24. NOT SATISFIED. 12 BIKE PARKING SPACES SHALL BE | | | PROVIDED THROUGHOUT THE PROJECT, CLOSE TO BUILDING | | | ENTRANCE AND RETAIL ENTRANCES. BIKE PARKING FOR THE | | | GENERAL PUBLIC SHALL BE INSTALLED AROUND THE PROJECT | | | WITHIN THE PUBLIC REALM. PLEASE PROVIDE 1 BIKE SPACE | | | PER EVERY 100 FEET OF STREET FRONTAGE. THE PROVIDED | | | BIKE PARKING INSIDE THE BUILDING IS FOR THE BUILDING | | | TENANTS. - PREVIOUS COMMENT: PUBLIC BIKE RACKS ARE | | | REQUIRED ALONG THE STREET FRONTAGE AT A RATIO OF ONE | | | PARKING SPACE/100 LINEAR FEET OF FRONTAGE. | | | 25. PARTIALLY SATISFIED. TO BE CONFIRMED DURING | | | BUILDING PERMIT. ANY CHANGES IN GRADE ELEVATION BETWEEN | | | THE SIDEWALK AND THE FINISHED FLOOR SHALL BE ABSORBED | | | INSIDE THE BUILDING. ? PREVIOUS COMMENT: PLEASE PROVIDE | | | STREET SECTIONS INCLUDING GROUND FLOOR ELEVATIONS TO | | | CONFIRM EXISTING STREET AND SIDEWALK ELEVATIONS CAN BE | | | MET WITH THE NEW PROJECT. | | | 26. SATISFIED. A MAXIMUM OF 30 % OF THE PARKING SPACES | | | CAN BE COMPACT SPACES. PLEASE PROVIDE INFORMATION TO | | | CONFIRM COMPLIANCE. ? PREVIOUS COMMENT: PLEASE CONFIRM | | | YOU DO NOT EXCEED THE MAXIMUM ALLOWABLE COMPACT PARKING | | | SPACES FOR THE PROJECT. | | | 27. THE PARKING PROJECTIONS IN SOME OF THE UPPER FLOORS | | | ENCROACH INTO THE MINIMUM SETBACK. PLEASE ADJUST. A | | | MAXIMUM 2 FEET FOR ARCHITECTURAL ENCROACHMENT IS | | | ALLOWED. | | | FOR RESUBMITTAL, PLEASE SUBMIT TWO COPIES OF ALL | | | DRAWINGS AND SUPPORTING DOCUMENTATION AND ONE CD WITH | | | ELECTRONIC COPIES OF ALL DOCUMENTS AND DRAWINGS. PLEASE | | | INCLUDE A RESPONSE LETTER ADDRESSING EACH OF THE | | | COMMENTS. | | | 28. IF THE GROUDN FLOOR PARKING IS GOING TO BE USED BY | | | EMPLOYEES, PLEASE INDICATE THE PEDESTRIAN ACCESS TO THE | | | PARKING AREA. | | | | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
05-17-2021 |
|
|
Cont ID |
|
| Sent By |
aaponte |
Date |
05-17-2021 |
Time |
16:10 |
Rev Time |
0.00 |
| Received By |
aaponte |
Date |
04-23-2021 |
Time |
16:08 |
Sent To |
|
|
| Notes |
| 2021-05-17 16:10:14 | COMMENTS TO 4/23/21 SET | | | 1. NOT SATISFIED. THE PROJECT EXCEEDS THE MAXIMUM | | | SQUARE FOOTAGE CURRENTLY ALLOCATED FOR OFFICE IN THE | | | DRI CAPACITY TABLE. BASED ON THE LATEST NUMBERS, A | | | CONVERSION FROM OTHER CATEGORY WOULD BE NEEDED TO ALLOW | | | 62,833 SF OF ADDITIONAL OFFICE SPACE. PLEASE SUBMIT | | | CONVERSION ANALYSIS ACCORDING TO ORDINANCE | | | 4412-12.-PREVIOUS COMMENT: PLEASE PROVIDE A GROSS | | | SQUARE FOOTAGE CALCULATION FOR EACH USE TO DETERMINE | | | THE NEED FOR CONVERSION CAPACITY FROM THE CITYPLACE | | | DRI. CURRENTLY THERE IS ONLY 383,429 SF OF OFFICE | | | SPACE, AND 32,337 SF OR RETAIL AVAILABLE IN THE POOL. | | | IT SEEMS THE GBA OF PROPOSED OFFICE MAY EXCEED THE | | | AVAILABLE SF NECESSITATING A SF CONVERSION. | | | 2. SATISFIED.- PLEASE REVIEW ORDINANCE NO. 4412-12 AND | | | PROVIDE CONFIRMATION OF COMPLIANCE FOR ALL APPLICABLE | | | ITEMS. | | | 3. NOT SATISFIED. STAFF UNDERSTAND WAIVERS ARE | | | REQUESTED. PLEASE PROVIDE SCHEMATIC DRAWING INDICATING | | | THE COMPLIANCE AT GROUND FLOOR AND THE WAIVERS | | | REQUESTED FOR FLOORS 2ND-5TH. IF THE AREA OF THE PASEO | | | MEETS THE PUBLIC OPEN SPACE REQUIREMENTS, IT CAN BE | | | COUNTED AS ACTIVE USE AS IT IS ADJACENT TO ACTIVE USES | | | ON BOTH SIDES.- PREVIOUS COMMENT: PLEASE PROVIDE | | | GRAPHIC INFORMATION TO DEMONSTRATE COMPLIANCE WITH THE | | | ACTIVE USE REQUIREMENTS. | | | 4. NOT SATISFIED. SOME SUGGESTIONS TO REDUCE THE NUMBER | | | OF WAIVERS REQUESTED: | | | A. AS IT SEEMS THE PROPOSED VALET PARKING SPACES ON THE | | | GROUND FLOOR ARE NOT USABLE (DUE TO CIRCULATION | | | PATTERNS) THE GROUND FLOOR ACTIVE USE ALONG DIXIE HWAY | | | COULD BE MODIFIED TO MEET THE MINIMUM DEPTH REQUIRED. | | | B. PLANAR BREAKS COULD BE MEASURED HORIZONTALLY WITH | | | THE VARIATION ON THE BUILDING PLANE OF EACH PARKING | | | LEVEL. | | | C. CONSIDERING THE CANOPY AT THE MAIN ENTRANCE IS AT | | | 33? IN HEIGHT, TREES MAY BE INSTALLED ALONG THE CURB TO | | | COMPLY WITH TREE PLANTING REQUIREMENT. | | | PREVIOUS COMMENT: PROJECT IS REQUESTING 22 DIFFERENT | | | WAIVERS FROM REGULATIONS. PLEASE FURTHER STUDY OPTIONS | | | TO COMPLY WITH CODE REQUIREMENTS OR REDUCE THE WAIVER | | | REQUEST. SOME OF THE WAIVERS THAT CAN BE REDUCED | | | INCLUDE: | | | A. SATISFIED-PORTE COCHERE. CONSIDERING THE DROP-OFF | | | AREA ON QUADRILLE CANNOT MEET THE PORTE COCHERE | | | REQUIREMENTS STAFF RECOMMENDS UTILIZING A REGULAR | | | ON-STREET DROP-OFF. | | | B. SATISFIED-TOWER AND GARAGE SEPARATION ARE NOT | | | APPLICABLE TO THIS DISTRICT. | | | 5. NOT SATISFIED. PLEASE PROVIDE SOME SECTIONS TO | | | INDICATE THE RELATION BETWEEN THE OFFICE TOWER LEVELS | | | AND THE GARAGE LEVELS. IF THE OFFICE LEVELS ARE USED, | | | GARAGE LEVELS 8,9 AND 10 SEEM TO EXCEED TO MAXIMUM | | | FOOTPRINT (TOWER LEVELS 6 AND 7).THE WAIVER REQUEST | | | SHOULD BE FOR THOSE TWO FLOORS TO EXCEED THE MAXIMUM | | | 55% BUILDING FOOTPRINT ALLOWED? PREVIOUS COMMENT: | | | PROJECT EXCEEDS THE MAXIMUM BUILDING FOOTPRINT ALLOWED | | | AT THE 6TH AND 7TH STORY (55%) AND ABOVE 8TH STORY | | | (50%) DUE TO THE PARKING GOING UP 10 STORIES. | | | JUSTIFICATION LIST THE WAIVER REQUEST TO EXCEED THE | | | MAXIMUM BUILDING FOOTPRINT FROM 6TH TO 24TH FLOOR. | | | PLEASE CLARIFY WHAT IS THE BUILDING FOOTPRINT PROVIDED | | | ABOVE THE 10TH LEVEL. THE PROJECT IS ALLOWED TO EXCEED | | | MAXIMUM BUILDING FOOTPRINTS ABOVE THE 5TH FLOOR, BUT IN | | | COMPLIANCE WITH THE CONDITIONAL SETBACK, WHICH IS NOT | | | PROVIDED AT THIS POINT. | | | 6. NOT SATISFIED- PROPOSED PARKING EXCEEDS THE MAXIMUM | | | ALLOWED. | | | MAXIMUM PARKING ALLOWED FOR THE PROJECT IS: | | | SOFT MAXIMUM = 398,590 SF AT1.5/1,000 = 598 SPACES | | | ADDITIONAL .75/1,000 WITH CONTRIBUTION TO TRANSIT = 299 | | | SPACES | | | ADDITIONAL WITH TDM STRATEGIES = 299 SPACES | | | TOTAL ALLOWED = 1,196 SPACES | | | PARKING PROPOSES ON APRIL 23, 21 VERSION = 1,213 SPACES | | | TO INCREASE FROM THE SOFT MAXIMUM THE PROJECT CAN: | | | A. CONTRIBUTE TO THE TRANSIT OPERATION FUND (EXACT | | | AMOUNT TO BE CALCULATED). THAT WILL ALLOW 299 | | | ADDITIONAL PARKING SPACES. | | | B. THE ADDITIONAL SPACES REQUESTED UP TO THE HARD | | | MAXIMUM WOULD REQUIRE THE IMPLEMENTATION OF TDM | | | STRATEGIES. PLEASE IDENTIFY WHICH TDM STRATEGIES THE | | | PROJECT IS GOING TO IMPLEMENT. | | | | | | 7. NOT SATISFIED. REFUGE AREA MENTIONED IN THE RESPONSE | | | LETTER IS NOT SHOWN IN THE DRAWINGS. PREVIOUS COMMENT: | | | PROPOSED CURB CUT EXCEEDS THE MAXIMUM 25 FEET ALLOWED. | | | FURTHER DISCUSSION NECESSARY TO DETERMINE IF THE | | | SERVICE DRIVE CAN BE REDUCED, OR IF THERE ARE ANY | | | MEASURES TO MITIGATE THE IMPACT ON PEDESTRIANS. | | | 8. SATISFIED.- SIDEWALK ELEVATION SHALL BE MAINTAINED | | | ACROSS THE DRIVEWAY. | | | 9. NOT SATISFIED PLEASE PROVIDE PRE-APPROVAL LETTER | | | FROM FDOT TO CONFIRM THEY WILL ACCEPT THE DROP OFF AREA | | | ON QUADRILLE BLVD AND THE LOCATION OF THE CURB | | | CUTS.-PREVIOUS COMMENT: TPS LETTER FROM COUNTY MENTIONS | | | THE POSSIBLE NEED FOR DECELERATION LANES TO ACCESS | | | GARAGE. PLEASE PROVIDE A PRE-DETERMINATION LETTER FROM | | | FDOT CONFIRMING THE AGENCY APPROVAL FOR THE PROPOSED | | | SIDE PLAN (DRIVEWAYS, TREES ETC.) | | | 10. PARTIALLY SATISFIED. PLEASE PROVIDE NARRATIVE ON | | | THE CURB SIDE MANAGEMENT OF ON-STREET DROP OFF/PICK UP | | | AREA PROPOSED ON QUADRILLE BLVD.- PREVIOUS COMMENT: | | | PLEASE PROVIDE FOR A CURB SIDE MANAGEMENT PLAN AND A | | | FREIGHT DELIVERY MANAGEMENT PLAN. | | | 11.NOT SATISFIED. PROPOSED VALET LOCATION IS NOT | | | FUNCTIONAL, THE VALET OPERATION IS BLOCKING THE TRAVEL | | | LANES. A SEPARATE AREA FOR STACKING IS NEEDED. PLEASE | | | INDICATE THE TRAVEL PATHS FOR CARS RECEIVED AT THE 2ND | | | FLOOR VALET TO THE GROUND FLOOR VALET PARKING AREA. | | | VALET CARS SHOULD NOT CIRCULATE IN THE PUBLIC ROW. ? | | | PREVIOUS COMMENT: PLEASE PROVIDE INFORMATION REGARDING | | | THE OPERATION OF THE VALET SERVICE FOR THE BUILDING. | | | PLEASE IDENTIFY THE LOCATION OF THE VALET PARKING | | | DROP-OFF /PICK UP AREA INSIDE THE GARAGE. | | | 12. TO BE INCLUDED AS A CONDITON OF APPROVAL- DUE TO | | | THE PROPOSAL TO INCLUDE TANDEM PARKING SPACES, VALET | | | SERVICE WILL BE REQUIRED FOR THE PROJECT. A RESTRICTIVE | | | COVENANT WILL BE REQUIRED FOR THE PROJECT. | | | | | | 13. PARTIALLY SATISFIED. STAFF RECOMMENDS MORE | | | REALISTIC RENDERINGS FOR THE PB AND CITY COMMISSION | | | MEETING. CAN THE CONCRETE PARAPET THAT CREATES THE | | | ILLUSION OF SLAB THICKNESS BE TALLER TO FURTHER SCREEN | | | THE CARS FROM VIEW? WHAT ABOUT SOME VEGETATION IN SOME | | | OF THE SLAB PROJECTIONS THAT COMPLEMENT THE ART | | | INSTALLATION AND HELP SCREEN THE CARS?? PREVIOUS | | | COMMENT: ADDITIONAL INFORMATION SHALL BE PROVIDED | | | REGARDING THE PROPOSED DESIGN OF THE PARKING GARAGE. | | | STAFF RECOMMENDS APPLICANT TO PROVIDE DETAILED SECTIONS | | | TO FULLY EXPLAIN THE SPECIAL DESIGN OF THE GARAGE SLABS | | | THAT WILL JUSTIFY THE LACK OF ACTIVE USES. REALISTIC | | | RENDERING IMAGES ARE ALSO RECOMMENDED TO FULLY DEPICT | | | THE IMAGE OF THE GARAGE AND ALLOW A COMPLETE | | | UNDERSTANDING OF THE GARAGE IMPACT ON THE SURROUNDING. | | | RENDERINGS SHALL BE PROVIDED FROM ALL THE DIFFERENT | | | VIEW POINTS OF THE GARAGE (DIXIE, LAKEVIEW, OKEECHOBEE) | | | AND FROM STREET LEVEL PERSPECTIVE AS WELL AS FROM UPPER | | | LEVELS FROM SURROUNDING BUILDINGS. | | | PLANS INDICATE SOME OF THE PARKING SPACES AT THE EDGE | | | OF THE SLAB, ARE THE CARS VISIBLE FROM OUTSIDE? | | | 14. PARTIALLY SATISFIED. SECTION IN A513 DOES NOT SEEM | | | TO MATCH FLOOR PLANS BUT SEEMS TO INDICATE SOME | | | ADDITIONAL SETBACK ABOVE FLOOR 6TH BEYOND THE MINIMUM | | | REQUIRED. PLEASE INDICATE THE MINIMUM SETBACK LINE AND | | | THE CONDITIONAL SETBACK FOR PARKING USES TO DETERMINE | | | THE EXTENT OF THE WAIVER IN EACH PARKING LEVEL. | | | PREVIOUS COMMENT: PLEASE INDICATE THE MINIMUM SETBACK | | | IN THE GARAGE SECTIONS TO IDENTIFY THE EXTEND OF THE | | | ENCROACHMENTS INDICATED IN THE FLOOR PLANS. ARE THE | | | ENCROACHMENTS PROPOSED ARCHITECTURAL FEATURES? | | | 15. NOT SATISFIED. SOME ADDITIONAL TREES CAN BE | | | INSTALLED NORTH AND SOUTH OF THE CANOPY TO BRING THE | | | PROJECT CLOSER INTO COMPLIANCE WITH THE REQUIREMENT. | | | PLEASE SUGGEST WHERE THE REMAINING TREES CAN BE | | | LOCATION AROUND THE PROJECT. PREVIOUS COMMENT: STREET | | | TREES ARE REQUIRED ALONG THE QUADRILLE BOULEVARD | | | FRONTAGE EVERY 30 FEET. | | | 16. SATISFIED. SIDEWALK ALONG THE QUADRILLE FRONTAGE IS | | | 10 FEET AT ITS NARROWEST POINT. PREVIOUS COMMENT: | | | SIDEWALK ALONG QUADRILLE BOULEVARD BY THE BUILDING | | | ENTRANCE SHALL BE A MINIMUM OF 8 FEET IN WIDTH. | | | 17. PARTIALLY SATISFIED. PLEASE PROVIDE A FA?ADE DETAIL | | | DEPICTING THE TREATMENT OF THE FA?ADE TO ACCOMMODATE | | | THE UTILITY ELEMENTS. ALSO PLEASE CLARIFY HOW IS THE | | | ACCESS TO THE FIRE BACKFLOW. - PREVIOUS COMMENT: ALL | | | BACKFLOW PREVENTORS AND ABOVE GROUND UTILITY | | | CONNECTIONS AT THE GROUND LEVEL NEED TO BE SCREENED | | | FROM VIEW. FURTHER DISCUSSION IS NECESSARY TO DETERMINE | | | THE MOST APPROPRIATE LOCATION. LANDSCAPE DRAWINGS AND | | | SITE PLAN DRAWINGS SHALL REFLECT THE PROPOSED LOCATION | | | OF SUCH EQUIPMENT. | | | 18. NOT SATISFIED. - A COMPLETE SIGNAGE PACKET SHALL BE | | | SUBMITTED FOR APPROVAL AS PART OF THE LEVEL III SITE | | | PLAN APPROVAL PROCESS BY THE CITY COMMISSION. | | | 19. SATISFIED. BIKE PARKING REQUIRED IS 120 SPACES. - | | | PREVIOUS COMMENT: THE BIKE STORAGE INDICATED ON THE | | | GROUND FLOOR ALONG OKEECHOBEE BLVD DOES NOT SEEM ENOUGH | | | TO ACCOMMODATE THE 120 BIKE SPACES REQUIRED FOR THE | | | PROJECT (1/10 PARKING SPACES) | | | 20. NOT SATISFIED. SHEET A112 WAS NOT INCLUDED IN | | | SUBMITTED SET. BASED ON THE 382,211 SF OF NET OFFICE | | | SPACE, THE PROJECT IS REQUIRED TO PROVIDE 13 SHOWERS | | | AND CHANGING FACILITIES. SHOWERS SHALL BE IN AREAS | | | ACCESSIBLE TO ALL TENANTS. PLEASE INDICATE PRELIMINARY | | | LOCATION FOR SITE PLAN APPROVAL PROCESS- PREVIOUS | | | COMMENT: PLEASE INDICATE THE LOCATION OF THE SHOWER AND | | | CHANGING ROOMS REQUIRED FOR THE PROJECT (1 SHOWER AND | | | CHANGING /30,000 SF OF OFFICE). | | | 21. SATISFIED. PLEASE INCLUDE A NOTE CALLING OUT THE | | | NON-REFLECTIVE NATURE OF THE GLASS IN THE FA?ADE. - | | | PLEASE CONFIRM THE PROPOSED GLASS IS NOT A REFLECTIVE | | | GLASS TO CAUSE IMPACT OF DRIVERS. | | | 22. NOT SATISFIED. PLEASE OBTAIN A PRE-APPROVAL LETTER | | | FROM FDOT TO CONFIRM THEY WILL ALLOW THE PROPOSED | | | PLACEMENT OF TREES ALONG THE CURB LINE. - PLEASE | | | CONFIRM FDOT HAS APPROVED THE LOCATIONS OF THE PROPOSED | | | TREES ALONG THE CURB. | | | 23. PARTIALLY SATISFIED. PEDESTRIAN CROSSINGS SHOULD | | | HAVE THERMOPLASTIC ZEBRA PATTERN AND ADA RAMPS. ? | | | PREVIOUS COMMENT: PLEASE PROVIDE INFORMATION TO CONFIRM | | | COMPLIANCE WITH THE PROVISION OF PEDESTRIAN CROSSINGS | | | AT ALL INTERSECTIONS. | | | 24. NOT SATISFIED. BIKE PARKING FOR THE GENERAL PUBLIC | | | SHALL BE INSTALLED AROUND THE PROJECT WITHIN THE PUBLIC | | | REALM. PLEASE PROVIDE 1 BIKE SPACE PER EVERY 100 FEET | | | OF STREET FRONTAGE. THE PROVIDED BIKE PARKING INSIDE | | | THE BUILDING IS FOR THE BUILDING TENANTS. - PREVIOUS | | | COMMENT: PUBLIC BIKE RACKS ARE REQUIRED ALONG THE | | | STREET FRONTAGE AT A RATIO OF ONE PARKING SPACE/100 | | | LINEAR FEET OF FRONTAGE. | | | 25. PARTIALLY SATISFIED. ANY CHANGES IN GRADE ELEVATION | | | BETWEEN THE SIDEWALK AND THE FINISHED FLOOR SHALL BE | | | ABSORBED INSIDE THE BUILDING. ? PREVIOUS COMMENT: | | | PLEASE PROVIDE STREET SECTIONS INCLUDING GROUND FLOOR | | | ELEVATIONS TO CONFIRM EXISTING STREET AND SIDEWALK | | | ELEVATIONS CAN BE MET WITH THE NEW PROJECT. | | | 26. NOT SATISFIED. A MAXIMUM OF 30 % OF THE PARKING | | | SPACES CAN BE COMPACT SPACES. PLEASE PROVIDE | | | INFORMATION TO CONFIRM COMPLIANCE. ? PREVIOUS COMMENT: | | | PLEASE CONFIRM YOU DO NOT EXCEED THE MAXIMUM ALLOWABLE | | | COMPACT PARKING SPACES FOR THE PROJECT. | | | | | | FOR RESUBMITTAL, PLEASE SUBMIT FOUR COPIES OF ALL | | | DRAWINGS AND SUPPORTING DOCUMENTATION AND ONE CD WITH | | | ELECTRONIC COPIES OF ALL DOCUMENTS AND DRAWINGS. PLEASE | | | INCLUDE A RESPONSE LETTER ADDRESSING EACH OF THE | | | COMMENTS. THE DEADLINE FOR RESUBMITTAL IS 5/28/21 TO BE | | | INCLUDED IN THE JULY 20 PLANNING BOARD AGENDA. | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
01-13-2021 |
|
|
Cont ID |
|
| Sent By |
aaponte |
Date |
01-13-2021 |
Time |
18:26 |
Rev Time |
0.00 |
| Received By |
aaponte |
Date |
12-08-2020 |
Time |
15:23 |
Sent To |
|
|
| Notes |
| 2021-01-13 18:28:05 | | | | 1. PLEASE PROVIDE A GROSS SQUARE FOOTAGE CALCULATION | | | FOR EACH USE TO DETERMINE THE NEED FOR CONVERSION | | | CAPACITY FROM THE CITYPLACE DRI. CURRENTLY THERE IS | | | ONLY 383,429 SF OF OFFICE SPACE, AND 32,337 SF OR | | | RETAIL AVAILABLE IN THE POOL. IT SEEMS THE GBA OF | | | PROPOSED OFFICE MAY EXCEED THE AVAILABLE SF | | | NECESSITATING A SF CONVERSION. | | | 2. PLEASE REVIEW ORDINANCE NO. 4412-12 AND PROVIDE | | | CONFIRMATION OF COMPLIANCE FOR ALL APPLICABLE ITEMS. | | | 3. PLEASE PROVIDE GRAPHIC INFORMATION TO DEMONSTRATE | | | COMPLIANCE WITH THE ACTIVE USE REQUIREMENTS. | | | 4. PROJECT IS REQUESTING 22 DIFFERENT WAIVERS FROM | | | REGULATIONS. PLEASE FURTHER STUDY OPTIONS TO COMPLY | | | WITH CODE REQUIREMENTS OR REDUCE THE WAIVER REQUEST. | | | SOME OF THE WAIVERS THAT CAN BE REDUCED INCLUDE: | | | A. PORTE COCHERE. CONSIDERING THE DROP-OFF AREA ON | | | QUADRILLE CANNOT MEET THE PORTE COCHERE REQUIREMENTS | | | STAFF RECOMMENDS UTILIZING A REGULAR ON-STREET | | | DROP-OFF. | | | B. TOWER AND GARAGE SEPARATION ARE NOT APPLICABLE TO | | | THIS DISTRICT. | | | 5. PROJECT EXCEEDS THE MAXIMUM BUILDING FOOTPRINT | | | ALLOWED AT THE 6TH AND 7TH STORY (55%) AND ABOVE 8TH | | | STORY (50%) DUE TO THE PARKING GOING UP 10 STORIES. | | | JUSTIFICATION LIST THE WAIVER REQUEST TO EXCEED THE | | | MAXIMUM BUILDING FOOTPRINT FROM 6TH TO 24TH FLOOR. | | | PLEASE CLARIFY WHAT IS THE BUILDING FOOTPRINT PROVIDED | | | ABOVE THE 10TH LEVEL. THE PROJECT IS ALLOWED TO EXCEED | | | MAXIMUM BUILDING FOOTPRINTS ABOVE THE 5TH FLOOR, BUT IN | | | COMPLIANCE WITH THE CONDITIONAL SETBACK, WHICH IS NOT | | | PROVIDED AT THIS POINT. | | | 6. PROPOSED PARKING EXCEEDS THE SOFT MAXIMUM. | | | OFFICE NET INTERIOR = 382,740SF (574-1,149MAX) | | | RETAIL NET INTERIOR = 18,818SF (29MIN/58MAX) | | | CAFE NET INTERIOR=480SF | | | | | | AS A RESULT, THE PARKING ALLOWED IS: | | | SOFT MAXIMUM PARKING =603 SPACES | | | HARD MAXIMUM 1,207 SPACES | | | | | | TO INCREASE FROM THE SOFT MAXIMUM THE PROJECT CAN: | | | 1. CONTRIBUTE TO THE TRANSIT OPERATION FUND (EXACT | | | AMOUNT TO BE CALCULATED). THAT WILL ALLOW 301 | | | ADDITIONAL PARKING SPACES. | | | 2. THE ADDITIONAL SPACES REQUESTED UP TO THE HARD | | | MAXIMUM WOULD REQUIRE THE IMPLEMENTATION OF TDM | | | STRATEGIES. PLEASE IDENTIFY WHICH TDM STRATEGIES THE | | | PROJECT IS GOING TO IMPLEMENT. | | | | | | 7. PROPOSED CURB CUT EXCEEDS THE MAXIMUM 25 FEET | | | ALLOWED. FURTHER DISCUSSION NECESSARY TO DETERMINE IF | | | THE SERVICE DRIVE CAN BE REDUCED, OR IF THERE ARE ANY | | | MEASURES TO MITIGATE THE IMPACT ON PEDESTRIANS. | | | 8. SIDEWALK ELEVATION SHALL BE MAINTAINED ACROSS THE | | | DRIVEWAY. | | | 9. TPS LETTER FROM COUNTY MENTIONS THE POSSIBLE NEED | | | FOR DECELERATION LANES TO ACCESS GARAGE. PLEASE PROVIDE | | | A PRE-DETERMINATION LETTER FROM FDOT CONFIRMING THE | | | AGENCY APPROVAL FOR THE PROPOSED SIDE PLAN (DRIVEWAYS, | | | TREES ETC.) | | | 10. PLEASE PROVIDE FOR A CURB SIDE MANAGEMENT PLAN AND | | | A FREIGHT DELIVERY MANAGEMENT PLAN. | | | 11.PLEASE PROVIDE INFORMATION REGARDING THE OPERATION | | | OF THE VALET SERVICE FOR THE BUILDING. PLEASE IDENTIFY | | | THE LOCATION OF THE VALET PARKING DROP-OFF /PICK UP | | | AREA INSIDE THE GARAGE. | | | 12. DUE TO THE PROPOSAL TO INCLUDE TANDEM PARKING | | | SPACES, VALET SERVICE WILL BE REQUIRED FOR THE PROJECT. | | | A RESTRICTIVE COVENANT WILL BE REQUIRED FOR THE | | | PROJECT. | | | | | | 13. ADDITIONAL INFORMATION SHALL BE PROVIDED REGARDING | | | THE PROPOSED DESIGN OF THE PARKING GARAGE. STAFF | | | RECOMMENDS APPLICANT TO PROVIDE DETAILED SECTIONS TO | | | FULLY EXPLAIN THE SPECIAL DESIGN OF THE GARAGE SLABS | | | THAT WILL JUSTIFY THE LACK OF ACTIVE USES. REALISTIC | | | RENDERING IMAGES ARE ALSO RECOMMENDED TO FULLY DEPICT | | | THE IMAGE OF THE GARAGE AND ALLOW A COMPLETE | | | UNDERSTANDING OF THE GARAGE IMPACT ON THE SURROUNDING. | | | RENDERINGS SHALL BE PROVIDED FROM ALL THE DIFFERENT | | | VIEW POINTS OF THE GARAGE (DIXIE, LAKEVIEW, OKEECHOBEE) | | | AND FROM STREET LEVEL PERSPECTIVE AS WELL AS FROM UPPER | | | LEVELS FROM SURROUNDING BUILDINGS. | | | PLANS INDICATE SOME OF THE PARKING SPACES AT THE EDGE | | | OF THE SLAB, ARE THE CARS VISIBLE FROM OUTSIDE? | | | 14.PLEASE INDICATE THE MINIMUM SETBACK IN THE GARAGE | | | SECTIONS TO IDENTIFY THE EXTEND OF THE ENCROACHMENTS | | | INDICATED IN THE FLOOR PLANS. ARE THE ENCROACHMENTS | | | PROPOSED ARCHITECTURAL FEATURES? | | | 15. STREET TREES ARE REQUIRED ALONG THE QUADRILLE | | | BOULEVARD FRONTAGE EVERY 30 FEET. | | | 16. SIDEWALK ALONG QUADRILLE BOULEVARD BY THE BUILDING | | | ENTRANCE SHALL BE A MINIMUM OF 8 FEET IN WIDTH. | | | 17. ALL BACKFLOW PREVENTORS AND ABOVE GROUND UTILITY | | | CONNECTIONS AT THE GROUND LEVEL NEED TO BE SCREENED | | | FROM VIEW. FURTHER DISCUSSION IS NECESSARY TO DETERMINE | | | THE MOST APPROPRIATE LOCATION. LANDSCAPE DRAWINGS AND | | | SITE PLAN DRAWINGS SHALL REFLECT THE PROPOSED LOCATION | | | OF SUCH EQUIPMENT. | | | 18. A COMPLETE SIGNAGE PACKET SHALL BE SUBMITTED FOR | | | APPROVAL AS PART OF THE LEVEL III SITE PLAN APPROVAL | | | PROCESS BY THE CITY COMMISSION. | | | 19. THE BIKE STORAGE INDICATED ON THE GROUND FLOOR | | | ALONG OKEECHOBEE BLVD DOES NOT SEEM ENOUGH TO | | | ACCOMMODATE THE 120 BIKE SPACES REQUIRED FOR THE | | | PROJECT (1/10 PARKING SPACES) | | | 20. PLEASE INDICATE THE LOCATION OF THE SHOWER AND | | | CHANGING ROOMS REQUIRED FOR THE PROJECT (1 SHOWER AND | | | CHANGING /30,000 SF OF OFFICE). | | | 21. PLEASE CONFIRM THE PROPOSED GLASS IS NOT A | | | REFLECTIVE GLASS TO CAUSE IMPACT OF DRIVERS. | | | 22. PLEASE CONFIRM FDOT HAS APPROVED THE LOCATIONS OF | | | THE PROPOSED TREES ALONG THE CURB. | | | 23. PLEASE PROVIDE INFORMATION TO CONFIRM COMPLIANCE | | | WITH THE PROVISION OF PEDESTRIAN CROSSINGS AT ALL | | | INTERSECTIONS. | | | 24. PUBLIC BIKE RACKS ARE REQUIRED ALONG THE STREET | | | FRONTAGE AT A RATIO OF ONE PARKING SPACE/100 LINEAR | | | FEET OF FRONTAGE. | | | 25. PLEASE PROVIDE STREET SECTIONS INCLUDING GROUDN | | | FLOOR ELEVATIONS TO CONFIRM EXISTING STREETAND SIDEWALK | | | ELEVATIONS CAN BE MET WITH THE NEW PROJECT. | | | 26. PLEASE CONFIRM YOU DO NOT EXCEED THE MAXIMUM | | | ALLOWABLE COMPACT PARKING SPACES FOR THE PROJECT. | | | | | | FOR RESUBMITTAL, PLEASE SUBMIT FOUR COPIES OF ALL | | | DRAWINGS AND SUPPORTING DOCUMENTATION AND ONE CD WITH | | | ELECTRONIC COPIES OF ALL DOCUMENTS AND DRAWINGS. PLEASE | | | INCLUDE A RESPONSE LETTER ADDRESSING EACH OF THE | | | COMMENTS. |
|
|
| |
Print |
|
Account Summary | Usage Policy | Privacy Policy