| 2020-10-05 16:54:20 | PLANS AND PLATS REVIEW COMMITTEE (PPRC) ZONING REVIEW |
| | ________________________________________ |
| | |
| | DATE OF REVIEW: 10.05.2020 |
| | PROJECT NO.: Z20090017 |
| | CASE NO.: PB 791KK |
| | ________________________________________ |
| | |
| | PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING |
| | REVIEW COMMENTS: |
| | |
| | 1. SHEET SP-1 - THE DIMENSION LINE FOR THE SIDE |
| | INTERIOR SETBACK AND THE POOL PAVILION OUTLINE ARE |
| | UNCLEAR AND CONFUSING. IT IS HARD TO DISTINGUISH THE |
| | OUTLINE OF THE PAVILION. |
| | |
| | 2. SHEET SP-1 - THE GENERATOR SHALL BE ENCLOSED BY A |
| | SOLID/OPAQUE FENCE OR WALL SURROUNDED BY LANDSCAPING. |
| | |
| | 3. SHEET SP-1 - PROVIDE THE ELEVATION POINTS FOR THE |
| | SIDEWALKS/STAIRS THAT ARE ENCROACHING INTO THE SETBACK |
| | (AS WAS SHOWN ON THE PLAN PREVIOUSLY). |
| | |
| | 4. SHEET SP-1 - COMPACT PARKING CALCULATIONS SHALL BE |
| | PROVIDED IN THE DATA TABLE AND SHOWN ON THE PLAN. |
| | |
| | 5. SHEET A-2.1 - THE SPACE TO THE RIGHT OF THE GARAGE |
| | ENTRANCE (AS YOU ENTER THE GARAGE) IS DIMENSIONED |
| | INCORRECTLY. IT SHOULD BE MEASURED TO THE CENTER OF THE |
| | DOUBLE-STRIPE. |
| | |
| | 6. SHEET A-2.1 - THERE ARE TWO (2) SPACES NEXT TO THE |
| | EXISTING COMPACT SPACES THAT SHOULD ALSO BE LABELED AS |
| | COMPACT (SHOULD BE FOUR (4) COMPACT SPACES IN A ROW). |
| | |
| | 7. SHEET A-2.1 - THE TURNAROUND FOR THE PROPOSED GATES |
| | ON THE GROUND FLOOR DOES NOT FUNCTION. |
| | |
| | 8. SHEET A-2.1 - WHY IS THE SIDEWALK/STAIR LEADING FROM |
| | THE PUBLIC SIDEWALK INTO THE MAILROOM WHEN THERE IS NO |
| | DOOR? THIS SHEET APPEARS TO SHOW A WINDOW, ALTHOUGH THE |
| | ELEVATION DOES SHOW A DOOR. PLEASE ENSURE CONSISTENCY |
| | ACROSS ALL PLANS. |
| | |
| | 9. SHEET A-2.1 - THE FENCING AND POOL DECK ON THIS PLAN |
| | DOES NOT MATCH THE SITE/LANDSCAPE PLANS. |
| | |
| | 10. SHEET A-3.1 - THE COLOR LEGEND STILL INDICATES THAT |
| | THE STONE IS BEING USED ON THE GARAGE ENTRY. |
| | ________________________________________ |
| | |
| | PLEASE NOTE THE FOLLOWING WHEN RESUBMITTING: |
| | |
| | A) WRITTEN RESPONSES TO COMMENTS MADE BY ALL |
| | DEPARTMENTS SHALL BE PROVIDED UPON RESUBMISSION. |
| | |
| | B) PDFS OF ALL REVISED PLANS AND/OR DOCUMENTS SHALL BE |
| | PROVIDED. |
| | |
| | C) PLEASE NOTE THAT RE-SUBMITTALS MAY BE SUBJECT TO |
| | ADDITIONAL COMMENTS. |
| | |
| | D) IF NO RESPONSE IS RECEIVED WITHIN 60 DAYS OF THE |
| | ISSUANCE OF THESE COMMENTS, THE APPLICATION WILL BE |
| | CONSIDERED WITHDRAWN AND ANY FURTHER ACTION WILL |
| | REQUIRE SUBMISSION OF A NEW DEVELOPMENT APPLICATION. |
| | |
| | E) PLEASE NOTE THAT YOU WILL BE PERMITTED ONE (1) |
| | RESUBMITTAL AT NO ADDITIONAL COST. IF PREVIOUSLY-ISSUED |
| | COMMENTS CONTINUE TO NOT BE SUFFICIENTLY ADDRESSED, THE |
| | APPLICANT WILL BE ACCESSED A RESUBMITTAL FEE. SUCH FEE |
| | WILL BE 20% OF THE ORIGINAL APPLICATION FEE. |
| | ________________________________________ |
| | |
| | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: |
| | |
| | JOHN P. ROACH, AICP, PRINCIPAL PLANNER |
| | CITY OF WEST PALM BEACH |
| | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION |
| | 401 CLEMATIS STREET - P.O. BOX 3147 |
| | WEST PALM BEACH, FLORIDA 33402 |
| | |
| | P: 561.822.1448 |
| | TTY: 800.955.8771 |
| | E: [email protected] |
| | |
| | W: WPB.ORG |
| | |