Plan Review Details - Project Z20080008
| Plan Review Stops For Project Z20080008 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
09-09-2020 |
|
|
Cont ID |
|
| Sent By |
elevesqu |
Date |
09-09-2020 |
Time |
20:23 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
09-09-2020 |
Time |
20:22 |
Sent To |
|
|
| Notes |
| 2020-09-09 20:30:55 | DEVELOPMENT SERVICES DEPARTMENT, BUILDING DIVISION, | | | COMMENTS: | | | | | | 1. THIS REVIEW IS A CURSORY REVIEW AS IT RELATES TO THE | | | SITE. IT IS NOT A REVIEW FOR FULL COMPLIANCE WITH | | | FLORIDA BUILDING CODE. THE FOLLOWING COMMENTS ARE TO BE | | | ADDRESSED FOR THE BUILDING PERMIT APPLICATION. | | | | | | 2. NUMBER OF ACCESSIBLE PARKING SPACES. THE VEHICULAR | | | PARKING TABLE ON SITE AND ZONING DATA SHEET A 0.01 DOES | | | NOT STATE HOW MANY ACCESSIBLE PARKING SPACES AND VAN | | | ACCESSIBLE PARKING SPACES ARE BEING PROVIDED RELATIVE | | | TO THE TOTAL NUMBER OF PARKING SPACES PROPOSED. WHEN | | | SUBMITTED FOR PERMIT THE PLANS SHALL CLEARLY SHOW THAT | | | THE MINIMUM NUMBER OF ACCESSIBLE PARKING SPACES | | | PROVIDED IS IN ACCORDANCE WITH THE FAIR HOUSING ACT AND | | | SECTION 208.2 OF FLORIDA ACCESSIBILITY CODE. | | | | | | 3. VAN ACCESSIBLE PARKING SPACES. PER SECTION 208.2.4 | | | OF FLORIDA ACCESSIBILITY CODE, ONE IN EVERY SIX | | | REQUIRED ACCESSIBLE SPACES (AT LEAST ONE) IN A PARKING | | | STRUCTURE, SHALL BE ?VAN ACCESSIBLE? AND DESIGNED IN | | | ACCORDANCE WITH SECTION OF 502 OF FLORIDA ACCESSIBILITY | | | CODE (VERTICAL CLEARANCE NOT LESS THAN 98 INCHES AT | | | SPACE AND VEHICULAR ACCESS ROUTE) | | | | | | 4. BUILDING SIZE. WHEN SUBMITTED FOR BUILDING PERMIT, | | | THE PLANS SHALL SHOW THAT THE TYPE OF CONSTRUCTION FOR | | | THE BUILDINGS WILL BE IN ACCORDANCE WITH THE HEIGHT, | | | AREA AND OCCUPANCY LIMITATIONS IN CHAPTER 5 OF THE | | | FLORIDA BUILDING CODE. | | | | | | 5. BUILDING LOCATION RELATIVE TO THE PROPERTY LINE AND | | | OTHER STRUCTURES. WHEN SUBMITTED FOR BUILDING PERMIT, | | | COMPLIANCE WITH ALL BUILDING SEPARATION, PERCENTAGE OF | | | OPENINGS AND OPENING PROTECTIVE REQUIREMENTS OF | | | CHAPTERS 6 AND 7 OF THE FLORIDA BUILDING CODE SHALL BE | | | VERIFIED. | | | | | | 6. ENCLOSED PARKING GARAGES. IF THE PARKING GARAGE DOES | | | NOT HAVE WALL OPENINGS, OR SUFFICIENT WALL OPENINGS TO | | | MEET THE DEFINITION OF AN OPEN PARKING GARAGE, IT WILL | | | BE CONSIDERED AN ENCLOSED PARKING GARAGE AND MUST HAVE | | | EXHAUST SYSTEMS. THE EXHAUST SYSTEMS SHALL BE DESIGNED | | | TO MINIMIZE NOISE LEVELS USING INLINE FAN SILENCERS OR | | | OTHER APPROVED METHODS. | | | | | | 7. SEPARATE PERMITS REQUIRED. ALL APPLICABLE PERMITS | | | AND SUB-PERMITS MUST BE OBTAINED BEFORE COMMENCING THE | | | WORK. SEPARATE PERMITS, PLANS AND FEES, ARE REQUIRED | | | FOR SIGNS, SWIMMING POOLS AND SPAS, GAS SYSTEMS, | | | GENERATORS, FIRE ALARM SYSTEMS, FIRE SPRINKLER AND | | | OTHER FIRE SUPPRESSION SYSTEMS, GREASE INTERCEPTORS, | | | SITE LIGHTING, SITE LANDSCAPE, SITE IRRIGATION, ETC. | | | | | | 8. CONTRACTOR VEHICLE PARKING. PROPERTY OWNER AND | | | CONTRACTOR SHALL MAKE ARRANGEMENTS FOR PARKING OF | | | CONTRACTOR VEHICLES TO MINIMIZE THE IMPACT ON ALL | | | NEIGHBORING PROPERTIES. | | | | | | 9. PROTECTION OF NEIGHBORING PROPERTY. PROPERTY OWNER | | | AND CONTRACTOR SHALL PROTECT ALL NEIGHBORING PROPERTY, | | | INCLUDING VEHICLES, FROM DAMAGE OR DIRT CAUSED BY THE | | | CONSTRUCTION, AND SHALL NOTIFY THE OCCUPANTS OF | | | NEIGHBORING PROPERTIES ABOUT ALL STAGES OF CONSTRUCTION | | | THAT MAY AFFECT THE USE OF THEIR PROPERTY. | | | | | | 10. BUILDING ADDRESS. EACH SEPARATE BUILDING, AND UNIT | | | WITH AN INDEPENDENT ENTRANCE FROM THE STREET, SHALL | | | HAVE A SEPARATE ADDRESS ASSIGNED BASED ON THE LOCATION | | | OF THE BUILDING ENTRANCE. FOR STREET ADDRESSING, | | | CONTACT CAROLINE PUELL, ADDRESSING COORDINATOR, AT | | | (561) 805 6659, OR BY EMAIL: [email protected] | | | | | | 11. ART IN PUBLIC PLACES. THIS PROJECT WILL BE SUBJECT | | | TO ART IN PUBLIC PLACES (AIPP) ASSESSMENT. FOR ADVICE | | | ON THE PROVISION OF PUBLIC ARTWORK IN LIEU OF THE AIPP | | | ASSESSMENT, CONTACT SYBILLE WELTER, ART IN PUBLIC | | | PLACES COORDINATOR, AT (561) 822-1521, OR BY EMAIL: | | | [email protected] | | | | | | ROBERT BROWN | | | BUILDING OFFICIAL | | | TEL: 561 805 6652 | | | EMAIL: [email protected] | | | |
|
|
| Review Stop |
ENG - PPRC |
ENGINEERING - PPRC |
| Rev No |
4 |
Status |
P |
Date |
04-02-2021 |
|
|
Cont ID |
|
| Sent By |
rrossano |
Date |
04-02-2021 |
Time |
|
Rev Time |
0.00 |
| Received By |
rrossano |
Date |
04-02-2021 |
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
ENG - PPRC |
ENGINEERING - PPRC |
| Rev No |
3 |
Status |
F |
Date |
03-08-2021 |
|
|
Cont ID |
|
| Sent By |
rrossano |
Date |
03-08-2021 |
Time |
|
Rev Time |
0.00 |
| Received By |
rrossano |
Date |
03-08-2021 |
Time |
|
Sent To |
|
|
| Notes |
| 2021-03-08 14:39:53 | COMMENTS PER MARK HURLEY, CUSTOMER SERVICE FIELD SUPV., | | | WPB PUBLIC UTILITIES, 561-822-2262, [email protected] : | | | | | | -WATER PLAN SHOWS A LARGE OVAL GROUND DEPRESSION NEAR | | | THE SOUTHEAST CORNER OF THE PROPOSED BUILDING NEAR THE | | | WATER METERS AND BACKFLOW ASSEMBLIES. PLEASE VERIFY IF | | | AREA WILL REMAIN LIKE THAT, OR IF GROUND ELEVATION WILL | | | INCREASE CLOSER TO THAT OF SURROUNDING AREA. (IF NOT, | | | CHANGES TO BACKFLOW ASSEMBLIES AND DOMESTIC METER | | | SERVICE, OR GROUND GRADE MAY BE NEEDED.) | | | -THERE ARE DUPLICATE WATER SERVICE STANDARD DETAILS FOR | | | THE ABOVE-GROUND METER SERVICE AND SMALL BACKFLOW | | | ASSEMBLY. PLEASE REMOVE APR 2018 AND NOV 2018 | | | RESPECTIVELY. | | | -FOR FORMAL ENGINEERING SUBMITTAL, MAKE SURE IRRIGATION | | | METER BOX IS DISTANCED AT LEAST THREE FEET FROM | | | ADJACENT LARGE POLE. SHOW/CALLOUT DISTANCE OR ADD NOTE | | | ON LABEL FOR IRRIGATION METER. (IF IRRIGATION BOX IS | | | ADJUSTED SOUTH, THEN FIRELINE MAY NEED ADJUSTMENT SOUTH | | | AS WELL.) | | | -PLEASE VERIFY THERE IS NO GATE OR FENCE BETWEEN | | | SIDEWALK AND PROPOSED METERS/BACKFLOWS. | | | | | | FEEL FREE TO CONTACT US IF YOU HAVE ANY QUESTIONS OR | | | CONCERNS, THANKS. | | | RICK ROSSANO, PROJECT COORDINATOR, ENGINEERING SERVICES | | | DEPARTMENT, 561-494-1098, [email protected] | | | |
|
|
| Review Stop |
ENG - PPRC |
ENGINEERING - PPRC |
| Rev No |
2 |
Status |
F |
Date |
10-28-2020 |
|
|
Cont ID |
|
| Sent By |
rrossano |
Date |
10-28-2020 |
Time |
|
Rev Time |
0.00 |
| Received By |
rrossano |
Date |
10-28-2020 |
Time |
|
Sent To |
|
|
| Notes |
| 2020-10-28 15:17:35 | COMMENTS PER RICK ROSSANO: | | | 1. ADD ADDRESS TO COVER SHEET. | | | 2. PROVIDE SWPPP FOR ENGINEERING SUBMITTAL SPECIFYING | | | STORM INLET PROTECTION ONSITE AND ALONG ENTIRE FRONTAGE | | | OF PROJECT. | | | | | | SHEET C-08: | | | 1. ADD NOTE TO REMOVE 8 IN. SANITARY TO BE ABANDONED. | | | 2. ADD NAVD/NGVD CONVERSION NOTE. | | | | | | SHEET C-10: | | | 1. UPDATE SANITARY SEWER STANDARD DETAILS TO MOST | | | CURRENT VERSIONS; EMAIL [email protected] FOR PDF | | | VERSIONS OR [email protected] FOR CAD VERSIONS. | | | 2. FOR MANHOLES IN RIGHT OF WAY, PROVIDE 5 FT. MIN. | | | INTERNAL DIAMETER. | | | | | | COMMENTS PER MARK HURLEY: | | | | | | -NEED UPDATE DEMO PLAN C-03 LABELS TO REFLECT THAT | | | EXISTING WATER SERVICES AND BACKFLOW ASSEMBLIES FOR | | | PHASE ONE ARE NOT BEING RELOCATED OR CHANGED UNTIL | | | DOWNSTREAM OF THE BACKFLOW ASSEMBLIES, AS INDICATED IN | | | PRIOR COMMENT RESPONSES. | | | | | | -ON UTILITY PLAN C-08, RELOCATE GATE VALVES FOR NEW | | | WATER SERVICES OUT OF THE SIDEWALK. | | | | | | -PROPOSED DOMESTIC 6 INCH METER IS STILL TOO FAR FROM | | | THE PROPERTY LINE. POSSIBLE SOLUTION MAY BE TO RELOCATE | | | FIRE AND IRRIGATION WATER SERVICES SOUTH OF THE GUY | | | ANCHOR EASEMENT, AND RELOCATE THE DOMESTIC METER EAST | | | (STILL NORTH OF THE GUY ANCHOR EASEMENT). | | | | | | -FOR FORMAL ENGINEERING SUBMITTAL, ADD LABELS TO THE | | | CITY WATER SERVICE PIPING SHOWING PIPE SIZE AND | | | MATERIAL TYPE USED. ALSO ADD LABELS ON THE REROUTED | | | PRIVATE PIPING FOR THE EXISTING WATER SERVICES THAT | | | SHOW PIPE MATERIAL FOR THE FIRE AND IRRIGATION LINES. | | | | | | -FOR FORMAL ENGINEERING SUBMITTAL, UPDATE LABELS FOR | | | IRRIGATION METER AND BACKFLOW ASSEMBLY TO REFERENCE | | | WS-1 AND WS-6 RESPECTIVELY. | | | | | | FEEL FREE TO CONTACT US IF YOU HAVE ANY QUESTIONS OR | | | CONCERNS, THANKS. | | | RICK ROSSANO, PROJECT COORDINATOR, ENGINEERING SERVICES | | | DEPARTMENT, 561-494-1098, [email protected] | | | |
|
|
| Review Stop |
ENG - PPRC |
ENGINEERING - PPRC |
| Rev No |
1 |
Status |
F |
Date |
09-03-2020 |
|
|
Cont ID |
|
| Sent By |
rrossano |
Date |
09-03-2020 |
Time |
|
Rev Time |
|
| Received By |
rrossano |
Date |
09-03-2020 |
Time |
|
Sent To |
|
|
| Notes |
| 2020-09-03 17:24:46 | FOLLOWING COMMENTS FROM RICK ROSSANO, PROJECT | | | COORDINATOR, ENGINEERING SERVICES DEPARTMENT, | | | 561-494-1098, [email protected] : | | | | | | 1. THE CITY OF WEST PALM BEACH HAS A NUMBER OF | | | REGULATIONS AND PERMIT REQUIREMENTS WHICH DIRECTLY | | | AFFECT THE DEVELOPMENT AND INSTALLATION OF WATER AND | | | WASTEWATER UTILITIES WITHIN THE CITY. PLEASE SEE | | | DEVELOPMENT PERMIT SUBMITTAL REQUIREMENTS AT THE LINK | | | BELOW: HTTP://WPB.ORG/CMSPAGES/GETAMAZONFILE.ASPX?PATH= | | | ~\WPB_WEBSITE\MEDIA\ENGINEERING\DEVELOPMENT-APPLICATION | | | -FULL-PACKAGE_2016.PDF&HASH=7BD4DD7EB6115181D8C5977BCC0 | | | 2A97B1960045731D3658206F27451722716EF | | | THIS AND OTHER RELATED ENGINEERING DOCUMENTS CAN BE | | | FOUND HERE: HTTP://WPB.ORG/DEPARTMENTS/ENGINEERING-PUBL | | | IC-WORKS/FORMS,-PERMITS-APPLICATIONS | | | 2. CODE OF ORDINANCES, CITY OF WEST PALM BEACH, | | | FLORIDA, CODIFIED THROUGH ORD. NO. 4183-08, ADOPTED | | | SEPT. 22, 2008. (SUPPLEMENT NO. 18) | | | CHAPTER 90 UTILITIES, ARTICLE I. SEC. 90-7. | | | POLICY REGARDING EXTENSION OF WATER OR SEWER SERVICE | | | FACILITIES OF THE CITY. | | | THE WATER AND WASTEWATER SERVICE AGREEMENTS AND THE | | | CONSTRUCTION PERMITS ADDRESS RESERVATION OF CAPACITY | | | BASED ON USAGE, METER SIZE AND FEES, DESIGN STANDARDS, | | | BACKFLOW PREVENTION, FIRE SERVICE AND IRRIGATION. | | | 3. AS OF DECEMBER 20, 2015, THE CITY OF WEST PALM BEACH | | | CROSS-CONNECTION CONTROL MANUAL HAS BEEN REVISED, | | | STATING "ALL BACKFLOW DEVICES MUST BE LEAD-FREE". FOR | | | MORE INFORMATION, REFER TO THE LINK BELOW: | | | HTTP://WPB.ORG/DEPARTMENTS/PUBLIC-UTILITIES/FORMS-PUBLI | | | CATIONS/BACKFLOW-CROSS-CONNECTION-CONTROL-MANUAL | | | 4. PLEASE SUBMIT A FORMAL AS-BUILT REQUEST FOR ALL CITY | | | OF WEST PALM BEACH-OWNED UTILITIES WITHIN THE PUBLIC | | | RIGHT OF WAY FOR THE ENTIRE EXTENT OF THE LIMITS OF | | | YOUR PROJECT. IDENTIFY TYPE OF UTILITY, LOCATION, PIPE | | | MATERIAL, AGE AND SIZE. PLEASE CONTACT JANICE TARBILL | | | IN THE WPB ENGINEERING SERVICES DEPARTMENT AT | | | [email protected] OR 561-494-1040 FOR FURTHER | | | ASSISTANCE. | | | 5. PLANS SHALL SHOW PROPOSED LOCATIONS AND DIMENSIONS | | | OF ALL WATER, STORMWATER, AND SANITARY AND SEWER LINES, | | | INCLUDING STUBS TO EACH PROPERTY LINE FOR WATER AND | | | SANITARY SEWERS, THE MAKE AND MODEL OF ALL VALVES, | | | METERS, AND OTHERS DEVICES TO BE INSTALLED ON THE | | | SYSTEM, CATCH BASINS, CULVERTS, DITCHES INCLUDING | | | GRADES, PIPES SIZES, MATERIALS, ELEVATIONS, | | | ASSUMPTIONS, CALCULATIONS, INVERT ELEVATIONS FOR ALL | | | INLETS AND MANHOLES AND PROFILES OF SANITARY SEWER | | | LINES. ALL AVAILABLE ELEVATION SHALL BE SHOWN ON THE | | | PROFILE VIEW. DIRECTION OF FLOW SHALL BE SHOWN ON PLAN | | | VIEW ON PLAN VIEW FOR ALL SANITARY AND STORM SEWERS. | | | PLEASE SHOW SLOPE % ON ALL SANITARY LINES AND CALL OUT | | | MATERIAL. ADDITIONALLY, PLAN VIEW SHALL SHOW ALL | | | EXISTING AND PROPOSED UNDERGROUND UTILITY LAYOUT, | | | INCLUDING FIBER OPTIC, ELECTRIC, GAS, AND CABLEVISION & | | | TELECOMMUNICATION FACILITIES LOCATED ON THE | | | RIGHT-OF-WAY. PROVIDE PROFILE AND CLEARANCES AT ALL | | | UTILITY CROSSINGS. | | | 6. CUT AND CAP UTILITIES NOT IN USE, AND REMOVE ANY | | | ABANDONED UTILITY LINES LARGER THAN 2 INCHES FROM CITY | | | ROW. | | | 7. PLEASE SUBMIT COMPLETED LOS ANALYSIS SUMMARY TABLE | | | DIRECTLY TO ENGINEERING (SHEET 33 OF CITY OF WPB | | | DEVELOPMENT APPLICATION). | | | 8. PROVIDE CALCULATIONS ON PLANS OF EXISTING AND | | | PROPOSED DEMANDS FOR WATER & SEWER (AVERAGE, MAXIMUM | | | AND PEAK) AND FIRE FLOW DEMANDS. CALCULATIONS SHALL BE | | | PER FAC 64E-6 FOR SEWER AND PER FAC 64-E.008 FOR WATER. | | | 9. SHOW VERTICAL DATUM AND DATUM CONVERSION INFORMATION | | | (NAVD 88 AND NGVD 29). | | | 10. PROVIDE CCTV VIDEO OF EXISTING SANITARY SEWER AND | | | STORMWATER FACILITIES ALONG ENTIRE PROJECT FRONTAGE. | | | 11. PLEASE PROVIDE CALCULATIONS OF REVISED PERVIOUS AND | | | IMPERVIOUS CALCULATIONS FOR THE PROPOSED IMPACTED | | | AREAS. | | | 12. PROVIDE ONSITE CLEANOUTS NEAR PROPERTY LINE FOR | | | PROPOSED SANITARY LATERALS. | | | 13. PLEASE LABEL WATER LINES AS PRIVATE WHERE | | | APPLICABLE. | | | 14. PLEASE PROVIDE ENLARGED VIEW ON PLANS OF PROPOSED | | | LOCATION OF WATER METER AND BACKFLOW PREVENTION; CALL | | | OUT HORIZONTAL SEPARATION OF PROPOSED WATER FROM | | | EXISTING 8 IN. SANITARY LINE. | | | 15. PROPOSED DOMESTIC WATER TAP SHOWN CONNECTING TO | | | EXISTING 8 IN. SANITARY LINE; PLEASE CORRECT. | | | 16. COORDINATE WITH MARK HURLEY, FIELD CUSTOMER SERVICE | | | SUPERVISOR WITH CITY OF WPB PUBLIC UTILITIES, REGARDING | | | PLACEMENT OF BACKFLOW DEVICES AND WATER METERS. CONTACT | | | HIM AT 561-494-2262 OR [email protected] | | | 17. PROVIDE DEDICATED UTILITY EASEMENTS TO ALLOW ACCESS | | | FOR CITY PERSONNEL TO PROPOSED UTILITY WATER METERS. | | | | | | | | | | | | THE FOLLOWING COMMENTS ARE FROM HONG XU, PROJECT | | | ENGINEER, CITY OF WPB PUBLIC UTILITIES, 561-494-1047, | | | [email protected] : | | | | | | PLEASE CLARIFY IF 6 INCH POTABLE WATER SERVICE, 8 INCH | | | DIP FIRE SERVICE AND 3 INCH IRRIGATION SERVICE ARE | | | EXISTING OR PROPOSED. HOW DO THEY CONNECT TO EXISTING | | | ONES? | | | | | | ARE THERE PROPOSED SEWER LATERALS CONNECTING TO | | | EXISTING 8 INCH VCP SANITARY SEWER MAIN FROM THE | | | PROPOSED BUILDING? | | | | | | ARE THERE ANY DRY UTILITIES THE AREA? | | | | | | PLEASE PROVIDE THE LEVEL OF SERVICE CALCULATION. | | | | | | THE FOLLOWING COMMENTS ARE FROM MARK HURLEY, FIELD | | | CUSTOMER SERVICE SUPERVISOR, WPB PUBLIC UTILITIES: | | | | | | -IS THE EXISTING PHASE ONE PROPERTY ADDRESS 350 S. | | | AUSTRALIAN OR 300 S. AUSTRALIAN? EXISTING WATER | | | SERVICES SHOW UP AS 300 S. AUSTRALIAN AVE IN UTILITY | | | BILLING SYSTEM. PLEASE ALSO VERIFY ADDRESS OF PHASE TWO | | | CONSTRUCTION. | | | | | | -IT APPEARS THERE ARE AT LEAST TWO EXISTING FIRE | | | HYDRANTS ON WEST SIDE OF OPEN SPACE DOWNSTREAM OF | | | EXISTING DCDA FIRELINE. WILL THOSE REMAIN IN SAME SPOT | | | OR BE RELOCATED NEARBY? | | | | | | -EXISTING FIRE DCDA NEEDS TO REMAIN ADJACENT CLEARWATER | | | DR. NEAR THE EASTERN PROPERTY LINE. ON FORMAL | | | ENGINEERING SUBMITTAL PLEASE LABEL POINT OF SERVICE | | | GATE VALVE. | | | | | | -EXISTING 6? DOMESTIC METER NEEDS TO BE INSTALLED | | | ABOVE-GROUND WHEN RELOCATED WITHOUT A LARGE VAULT PER | | | CONSTRUCTION STANDARD DETAILS. DO NOT REUSE WATER | | | SERVICE COMPONENTS SUCH AS FITTINGS, BOXES, LIDS, | | | VALVES, AND PIPING ? REPLACE THEM. PLAN THE WORK TO | | | MINIMIZE WATER SERVICE OUTAGES FOR CUSTOMERS. | | | | | | -KEEP WATER METER BOX, BACKFLOW ASSEMBLIES, AND VALVE | | | BOXES OUT OF SIDEWALKS AND PEDESTRIAN FOOT TRAFFIC. | | | | | | -RELOCATED BACKFLOW ASSEMBLIES WILL BE SUBJECT TO | | | BACKFLOW INSTALLATION INSPECTIONS. ANY BACKFLOW | | | ASSEMBLIES THAT ARE NOT LEAD-FREE COMPLIANT OR USC | | | APPROVED WILL NEED TO BE REPLACED WITH COMPLIANT | | | ASSEMBLIES. | | | | | | -EXISTING IRRIGATION METER IS 2?. IF NOT SUFFICIENT, | | | MAY NEED TO UPSIZE OR ADD ADDITIONAL WATER SERVICE. | | | | | | -WATER SERVICES AND METERS (EXISTING OR PROPOSED) ON | | | PRIVATE PROPERTY WILL REQUIRE UTILITY EASEMENT IF NOT | | | EXISTING ALREADY. BACKFLOW ASSEMBLIES CANNOT BE IN | | | UTILITY EASEMENTS. | | | | | | -NEED MORE INFORMATION ON LOCATION OF PROPOSED NEW | | | WATER SERVICES AND BACKFLOW ASSEMBLIES. IS THAT | | | LOCATION A GRASSY AREA WHERE THERE IS NO INTENTION OF | | | PEDESTRIAN OR VEHICLE TRAFFIC? THEY CANNOT BE LOCATED | | | IN ROADWAYS OR SIDEWALKS. | | | | | | -EXISTING FIRE HYDRANT NEAR SE CORNER OF PROPERTY | | | APPEARS TO BE LEFT OFF OF UTILITY PLAN. PLEASE ADD AND | | | LABEL. | | | | | | -PROPOSED DOMESTIC AND IRRIGATION WATER SERVICES WITH | | | METERS 3? AND LARGER SHOULD BE ABOVE-GROUND | | | INSTALLATION USING SD WS-3. | | | | | | -PLEASE RELOCATE PROPOSED WATER SERVICE PIPING SO THAT | | | IT DOES NOT RUN UNDERNEATH AND CLOSE TO FPL/AT&T | | | UTILITIES AND GUY WIRES. BUILDING STRUCTURE OR LOCATION | | | MAY NEED REDESIGN/ALTERATION TO FACILITATE THIS. ALSO | | | RELOCATE PROPOSED METERS CLOSER TO EASTERN PROPERTY | | | LINE SO THEY ARE WITHIN REACH OF CRANETRUCK OR BACKHOE, | | | AND PIPE DISTANCE TO WATER MAIN IS MINIMIZED. | | | | | | -VERIFY PROPOSED 8? DCDA LOCATION IS ACCEPTABLE WITH | | | CITY WPB FIRE MARSHAL. | | | | | | -SOME PARTS OF THE PROPERTY LIMITS APPEAR TO BE LEFT | | | OFF OF THE UTILITY PLANS. PLEASE ADD THOSE AREAS TO THE | | | PLANS USING MATCH-LINES AND EXTRA SHEETS IF NECESSARY. | | | | | | -FOR FORMAL ENGINEERING SUBMITTAL ADD ENLARGED/ZOOMED | | | AREA OF THE METERED WATER SERVICES AND BACKFLOW | | | ASSEMBLIES. | | | | | | -WPB UTILITIES RECOMMENDS PARALLEL/DUAL BACKFLOW | | | ASSEMBLIES ON LARGE DOMESTIC WATER SERVICES TO MINIMIZE | | | WATER OUTAGES DURING BACKFLOW ASSEMBLY MAINTENANCE. | | | | | | | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
4 |
Status |
P |
Date |
03-31-2021 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
03-31-2021 |
Time |
14:39 |
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
03-31-2021 |
Time |
14:38 |
Sent To |
|
|
| Notes |
| 2021-03-31 14:39:24 | FIRE HAS NO OBJECTIONS AND APPROVES. | | | | | | FIRE'S APPROVAL OF THIS SUBMITTED PROJECT DOES NOT | | | CONSTITUTE ITS FINAL REVIEW OR APPROVAL. | | | | | | FIRE SHALL REVIEW ALL SUBMITTED BUILDING PLANS AT THE | | | APPROPRIATE TIME AND IN ACCORDANCE WITH THE | | | REQUIREMENTS OF ALL APPLICABLE CODES AND STANDARDS. | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
03-05-2021 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
03-05-2021 |
Time |
13:33 |
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
03-05-2021 |
Time |
13:32 |
Sent To |
|
|
| Notes |
| 2021-03-05 13:33:07 | FIRE HAS NO OBJECTIONS AND APPROVES. | | | | | | FIRE'S APPROVAL OF THIS SUBMITTED PROJECT DOES NOT | | | CONSTITUTE ITS FINAL REVIEW OR APPROVAL. | | | | | | FIRE SHALL REVIEW ALL SUBMITTED BUILDING PLANS AT THE | | | APPROPRIATE TIME AND IN ACCORDANCE WITH THE | | | REQUIREMENTS OF ALL APPLICABLE CODES AND STANDARDS. | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
F |
Date |
11-04-2020 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
11-04-2020 |
Time |
09:47 |
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
11-04-2020 |
Time |
09:44 |
Sent To |
|
|
| Notes |
| 2020-11-04 09:52:44 | THOUGH FIRE HAS NO OBJECTION TO THE PROPOSED AND HAS | | | PASSED THE REVIEW, THE RESPONSES TO THE FIRE COMMENTS | | | ARE VAGUE AND GENERAL. | | | | | | FIRE AND ZONING STAFF IS REQUESTING GREATER DETAIL FOR | | | THE FDC, DDCV FIRE LINE, FIRE HYDRANTS, AND LOCATION OF | | | COMMAND ROOM. ADDITIONALLY, THE OCCUPANCY FOR THE POOL | | | DECK, AND SEPARATION DISTANCE OF STAIRWELLS COULD HAVE | | | MAJOR IMPACTS TO THE DESIGN OF THE STRUCTURE DURING | | | BUILDING PERMIT. | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
09-09-2020 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
09-09-2020 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
09-09-2020 |
Time |
08:55 |
Sent To |
|
|
| Notes |
| 2020-09-09 09:34:00 | THE FOLLOWING COMMENTS WERE SUBMITTED BY PETER LEDUC, | | | FIRE MARSHAL, BUREAU OF FIRE PREVENTION, WEST PALM | | | BEACH FIRE RESCUE. | | | | | | THIS REVIEW CAN ONLY BE CONSIDERED PRELIMINARY AS THE | | | DRAWINGS THAT WERE REVIEWED WERE NOT COMPLETE. | | | ADDITIONAL COMMENTS CAN BE EXPECTED WHEN FULL DRAWINGS | | | ARE SUBMITTED FOR PERMIT. | | | | | | THE FIRE PREVENTION BUREAU HAS NO OBJECTIONS TO THE | | | PROPOSED PROJECT. | | | | | | 1. CONSTRUCTION, DEMOLITION, AND RENOVATION TO COMPLY | | | WITH NFPA 241. EXTRA ATTENTION SHALL BE GIVEN TO THE | | | PERMITTING AND LOCATION OF CONSTRUCTION TRAILERS. A | | | PERMIT IS REQUIRED FOR ANY CONSTRUCTION TRAILER RELATED | | | TO THIS PROJECT. SEPARATION DISTANCES FROM MAIN | | | STRUCTURES AS WELL AS OTHER TRAILERS SHALL BE CLOSELY | | | MONITORED FOR THE REQUIREMENTS OF FIRE SPRINKLER | | | PROTECTION. | | | | | | 2. SITE ACCESS AND EXIT POINTS ARE TO BE CLEARLY | | | IDENTIFIED AND MAINTAINED FOR EMERGENCY VEHICLES DURING | | | ALL CONSTRUCTION ACTIVITIES. | | | | | | 3. THE BUILDING ADDRESS SHALL BE CLEARLY VISIBLE FROM | | | ALL ACCESS ROADWAYS, INCLUDING DURING CONSTRUCTION. | | | ADDRESS NUMBERS SHALL CONTRAST WITH THEIR BACKGROUND | | | AND SHALL NOT BE LESS THAN SIX (6) INCHES IN HEIGHT | | | WITH A ONE (1) INCH STROKE FOR ALL BUILDINGS. | | | | | | 4. DURING CONSTRUCTION, TRASH AND DEBRIS IS TO BE | | | REMOVED FROM THE SITE DAILY OR MORE OFTEN TO REDUCE THE | | | ACCUMULATION OF POTENTIAL LIFE AND FIRE SAFETY HAZARDS. | | | | | | 5. THE CONSTRUCTION OF THE BUILDING SHALL COMPLY WITH | | | THE 6TH EDITION OF THE FLORIDA FIRE PREVENTION CODE, | | | INCLUDING NFPA 1 & 101, AND ALL ASSOCIATED FIRE CODES. | | | | | | 6. ALL PARKING STRUCTURES SHALL COMPLY WITH NFPA 88A, | | | PARKING STRUCTURES AND NFPA 101, THE LIFE SAFETY CODE, | | | INCLUDING MORE SPECIFICALLY, CHAPTER 42 STORAGE | | | OCCUPANCIES (PARKING STRUCTURES) | | | | | | 7. A NFPA 13 COMPLAINT FIRE SPRINKLER SYSTEM AND NFPA | | | 14 COMPLIANT WET STANDPIPE SYSTEM ARE REQUIRED FOR THIS | | | STRUCTURE. TEMPORARY STANDPIPES ARE REQUIRED WHEN THE | | | BUILDING REACHES THREE LEVELS OR THIRTY FEET WHILE | | | BEING CONSTRUCTED. SEPARATE SHOP DRAWINGS, ARE REQUIRED | | | TO BE SUBMITTED, REVIEWED AND APPROVED BY THE FIRE | | | PREVENTION BUREAU PRIOR TO ANY INSTALLATION. | | | | | | A FDC LOCATION COULD NOT BE EASILY IDENTIFIED ON THE | | | CIVIL SITE PLAN. IT IS RECOMMENDED THAT HIGH RISES HAVE | | | TWO SEPARATE FDC LOCATED REMOTELY FOR EACH OTHER. ONE | | | FDC IS RECOMMENDED ON CLEARWATER NEAR THE SOUTH END | | | PARKING GARAGE ACCESS AND THE OTHER ALONG THE NORTH | | | ACCESS ROAD IN THE AREA OF THE FIRE COMMAND ROOM. CLOSE | | | COORDINATION WITH THE OFFICE OF THE FIRE MARSHAL IS | | | ENCOURAGED. | | | | | | 7A. PER NFPA 14 | | | | | | 6.4.5.4* FIRE DEPARTMENT CONNECTIONS SHALL BE LOCATED | | | NOT MORE THAN 100 FT (30.5 M) FROM THE NEAREST FIRE | | | HYDRANT CONNECTED TO AN APPROVED WATER SUPPLY. | | | | | | 7B. PLEASE REVIEW THE DISTANCE SEPARATION OF THE | | | STAIRWELLS AS THE SEPARATION DISTANCE IS NOT INDICATED. | | | | | | 7.3.2.2* WHERE THE MOST REMOTE PORTION OF A | | | NON-SPRINKLERED FLOOR OR STORY IS LOCATED IN EXCESS OF | | | 150 FT (45.7 M) OF TRAVEL DISTANCE FROM A HOSE | | | CONNECTION IN OR ADJACENT TO A REQUIRED EXIT OR THE | | | MOST REMOTE PORTION OF A SPRINKLERED FLOOR OR STORY | | | IS LOCATED IN EXCESS OF 200 FT (61 M) OF TRAVEL | | | DISTANCE FROM A HOSE CONNECTION IN OR ADJACENT TO A | | | REQUIRED EXIT, ADDITIONAL HOSE CONNECTIONS SHALL BE | | | PROVIDED, IN APPROVED LOCATIONS, WHERE REQUIRED BY THE | | | LOCAL FIRE DEPARTMENT OR THE AHJ. | | | | | | 7C. PER NFPA 1 | | | | | | 18.3 WATER SUPPLIES. | | | 18.3.1* AN APPROVED WATER SUPPLY CAPABLE OF SUPPLYING | | | THE REQUIRED FIRE FLOW FOR FIRE PROTECTION SHALL BE | | | PROVIDED TO ALL PREMISES UPON WHICH FACILITIES, | | | BUILDINGS, OR PORTIONS OF BUILDINGS ARE HEREAFTER | | | CONSTRUCTED OR MOVED INTO THE JURISDICTION. THE | | | APPROVED WATER SUPPLY SHALL BE IN ACCORDANCE WITH | | | SECTION 18.4. | | | | | | PER FLORIDA ADMINISTRATIVE CODE SECTION 61G15-32.004, | | | FIRE PROTECTION ENGINEERING DOCUMENTS SHALL INCLUDE THE | | | POINT OF SERVICE FOR THE WATER SUPPLY, A LIST OF | | | APPLICABLE NFPA STANDARDS APPLICABLE TO THE PROJECT, | | | CLASSIFICATION OF HAZARD OCCUPANCY FOR EACH ROOM OR | | | AREA, SUPPRESSION SYSTEM TYPE, DESIGN DENSITIES, WATER | | | SUPPLY DATA (FIRE PUMP DATA, HYDRANT FLOW TEST DATA) | | | AND ANY PERFORMANCE BASED INFORMATION SUCH AS | | | PRE-ENGINEERED SYSTEMS. | | | | | | FOR THE PROPOSED FIRE PUMP(S) , WHAT IS(ARE) THE | | | PRIMARY AND SECONDARY POWER SOURCES? | | | | | | 7D. THE LOCATION OF THE DDCV FIRE LINE LOCATION SHALL | | | MEET THE REQUIREMENTS OF NFPA 24 AND SHALL BE | | | COORDINATED WITH THE OFFICE OF FIRE MARSHAL, THE CITY'S | | | ENGINEERS OFFICE, THE LANDSCAPE PLANNER, AND THE CITY'S | | | PLANNING AND ZONING OFFICE. | | | | | | 8. A CLASS ?A? NFPA 72 COMPLIANT MONITORED FIRE ALARM | | | SYSTEM IS REQUIRED FOR THIS STRUCTURE. SEPARATE SHOP | | | DRAWINGS, ARE REQUIRED TO BE SUBMITTED, REVIEWED AND | | | APPROVED BY THE FIRE PREVENTION BUREAU PRIOR TO ANY | | | INSTALLATION. | | | | | | 9. ALL ELEVATORS SHALL BE EQUIPPED WITH A REGION 7 | | | KEYWAY SYSTEM. | | | | | | ALL NEW ELEVATORS SHALL CONFORM TO THE FIRE FIGHTER?S | | | EMERGENCY OPERATIONS REQUIREMENTS OF ASME A17.1/CSA | | | B44, SAFETY CODE FOR ELEVATORS. | | | | | | ANY BUILDING THAT IS MORE THAN THREE STORIES HIGH OR IN | | | WHICH THE VERTICAL DISTANCE BETWEEN THE BOTTOM TERMINAL | | | LANDING AND THE TOP TERMINAL LANDING EXCEEDS 25 FEET | | | MUST BE CONSTRUCTED TO CONTAIN AT LEAST ONE PASSENGER | | | ELEVATOR THAT IS OPERATIONAL AND WILL ACCOMMODATE AN | | | AMBULANCE STRETCHER 76 INCHES LONG AND 24 INCHES WIDE | | | IN THE HORIZONTAL POSITION. | | | | | | 10. COMPLETE LIFE SAFETY PLANS FOR EACH OCCUPANCY SHALL | | | BE PROVIDED THAT ILLUSTRATE OCCUPANT LOADS, TRAVEL | | | DISTANCES, COMMON PATHS OF TRAVEL, DEAD-END CORRIDORS, | | | EXIT SIGNS, EMERGENCY LIGHTING, EXITS LEADING TO A | | | PUBLIC WAY, FIRE EXTINGUISHER LOCATIONS, AND ALL FIRE | | | SAFETY FEATURES AND EQUIPMENT. | | | | | | 10A. PLEASE REVIEW THE OCCUPANCY LOAD OF THE POOL DECK | | | AND THE REQUIRED EXITING REQUIREMENTS AND EXIT | | | SEPARATION DISTANCES TO ENSURE COMPLAINCE WITH NFPA | | | 101, CH 12, ASSEMBLY OCCUPANCIES AND CH 7, MEANS OF | | | EGRESS. THREE OR MORE EXITS MAY BE REQUIRED. | | | | | | 11. ALL EXISTING AND NEW FIRE HYDRANTS PLANNED FOR THIS | | | DEVELOPMENT SHALL BE CLEARLY INDICATED AND IDENTIFIED | | | ON THE PLAN AND CLOSELY COORDINATED WITH THE BUREAU OF | | | FIRE PREVENTION. | | | | | | ALL NEW FIRE HYDRANTS AND FDC?S PLANNED FOR THIS | | | DEVELOPMENT SHALL BE CLOSELY COORDINATED WITH THE | | | BUREAU OF FIRE PREVENTION. PROPOSED FIRE HYDRANTS AND | | | FDC?S SHOULD BE LOCATED ON THE SAME SIDE OF THE STREET | | | OR ACCESS ROADWAY TO ALLOW FREE ACCESS FOR OTHER | | | ARRIVING EMERGENCY VEHICLES. | | | | | | 12. COMMAND ROOM | | | | | | THE FIRE COMMAND CENTER SHALL COMPLY WITH NFPA 1, | | | CHAPTER 11, BUILDING SERVICES; 11.9 AND SHALL CONTAIN | | | THE FOLLOWING FEATURES: | | | | | | A. SHALL BE A MINIMUM OF 200 FT SQUARED WITH A MINIMUM | | | DIMENSION OF 10 FT. | | | B. THE FIRE DEPARTMENT COMMUNICATIONS SYSTEM. | | | C. A TELEPHONE FOR FIRE DEPARTMENT USE WITH CONTROLLED | | | ACCESS TO THE PUBLIC TELEPHONE SYSTEM | | | D. SCHEMATIC BUILDING PLANS INDICATING THE TYPICAL | | | FLOOR PLAN AND DETAILING THE BUILDING CORE, MEANS OF | | | EGRESS, FIRE PROTECTION SYSTEMS, FIRE-FIGHTING | | | EQUIPMENT AND FIRE DEPARTMENT ACCESS AND THE LOCATION | | | OF FIRE WALLS, FIRE BARRIERS, FIRE PARTITIONS, SMOKE | | | BARRIERS AND SMOKE PARTITIONS | | | E. A WORK TABLE. | | | F. IF APPLICABLE, A HAZARDOUS MATERIAL MANAGEMENT PLAN | | | FOR THE BUILDING. | | | G. THE EMERGENCY VOICE/ALARM COMMUNICATION SYSTEM | | | CONTROL UNIT. | | | H. ANNUNCIATOR UNIT VISUALLY INDICATING THE LOCATION OF | | | THE ELEVATORS AND WHETHER THEY ARE OPERATIONAL | | | I. STATUS INDICATORS AND CONTROLS FOR AIR DISTRIBUTION | | | SYSTEMS. | | | J. CONTROLS FOR UNLOCKING STAIRWAY DOORS SIMULTANEOUSLY | | | K. SPRINKLER VALVE AND WATER FLOW DETECTOR DISPLAY | | | PANELS | | | L. EMERGENCY AND STANDBY POWER STATUS INDICATORS | | | M. FIRE PUMP STATUS INDICATORS | | | N. GENERATOR SUPERVISION DEVICES AND MANUAL START AND | | | TRANSFER FEATURES. | | | O. PUBLIC ADDRESS SYSTEM, WHERE SPECIFICALLY REQUIRED | | | BY OTHER SECTIONS OF THIS CODE | | | P. CONTROLS REQUIRED FOR SMOKE CONTROL | | | Q. ELEVATOR FIRE RECALL SWITCH IN ACCORDANCE WITH ASME | | | A17.1. | | | R. ELEVATOR EMERGENCY OR STANDBY POWER SELECTOR | | | SWITCH(ES), WHERE EMERGENCY OR STANDBY POWER IS | | | PROVIDED | | | | | | 11.8.6* EMERGENCY COMMAND CENTER. | | | | | | 11.8.6.1 AN EMERGENCY COMMAND CENTER SHALL BE PROVIDED | | | IN A | | | LOCATION APPROVED BY THE FIRE DEPARTMENT. | | | | | | 11.8.6.2 THE EMERGENCY COMMAND CENTER SHALL CONTAIN THE | | | FOLLOWING: | | | (1) VOICE FIRE ALARM SYSTEM PANELS AND CONTROLS | | | (2) FIRE DEPARTMENT TWO-WAY TELEPHONE COMMUNICATION | | | SERVICE | | | PANELS AND CONTROLS WHERE REQUIRED BY ANOTHER SECTION | | | OF THIS | | | CODE | | | (3) FIRE DETECTION AND FIRE ALARM SYSTEM ANNUNCIATION | | | PANELS | | | (4) ELEVATOR FLOOR LOCATION AND OPERATION ANNUNCIATORS | | | (5) ELEVATOR FIRE RECALL SWITCH IN ACCORDANCE WITH ASME | | | A17.1/CSA B44, SAFETY CODE FOR ELEVATORS AND ESCALATORS | | | (6) ELEVATOR EMERGENCY POWER SELECTOR SWITCH(ES) WHERE | | | PROVIDED | | | IN ACCORDANCE WITH ASME A17.1/CSA B44 | | | (7) SPRINKLER VALVE AND WATERFLOW ANNUNCIATORS | | | (8) EMERGENCY GENERATOR STATUS INDICATORS | | | (9) CONTROLS FOR ANY AUTOMATIC STAIRWAY DOOR UNLOCKING | | | SYSTEM | | | (10) FIRE PUMP STATUS INDICATORS | | | (11) TELEPHONE FOR FIRE DEPARTMENT USE WITH CONTROLLED | | | ACCESS TO THE | | | PUBLIC TELEPHONE SYSTEM | | | (12) STAIRWAY VIDEO MONITORING EQUIPMENT AS REQUIRED BY | | | 11.8.8 | | | | | | 13. RADIO | | | | | | NFPA 1, CHAPTER 11, BUILDING SERVICES; 11.10 TWO-WAY | | | RADIO ENHANCEMENT SERVICES. | | | | | | 11.10.1 IN ALL NEW AND EXISTING BUILDINGS, MINIMUM | | | RADIO SIGNAL STRENGTH FOR FIRE DEPARTMENT | | | COMMUNICATIONS SHALL BE MAINTAINED AT A LEVEL | | | DETERMINED BY THE AHJ. | | | | | | NFPA 72, 24.5.2* TWO-WAY RADIO COMMUNICATIONS | | | ENHANCEMENT SYSTEMS. | | | | | | 24.5.2.2 RADIO COVERAGE. RADIO COVERAGE SHALL BE | | | PROVIDED THROUGHOUT THE BUILDING AS A PERCENTAGE OF | | | FLOOR AREA AS SPECIFIED IN 24.5.2.2.1 THROUGH | | | 24.5.2.2.3. | | | 24.5.2.2.1 CRITICAL AREAS. CRITICAL AREAS, SUCH AS THE | | | EMERGENCY COMMAND CENTER(S), THE FIRE PUMP ROOM(S), | | | EXIT STAIRS, EXIT PASSAGEWAYS, ELEVATOR LOBBIES, | | | STANDPIPE CABINETS, SPRINKLER SECTIONAL VALVE | | | LOCATIONS, AND OTHER AREAS DEEMED CRITICAL BY THE | | | AUTHORITY HAVING JURISDICTION, SHALL BE PROVIDED WITH | | | 99 PERCENT FLOOR AREA RADIO COVERAGE. | | | 24.5.2.2.2 GENERAL BUILDING AREAS. GENERAL BUILDING | | | AREAS SHALL BE PROVIDED WITH 90 PERCENT FLOOR AREA | | | RADIO COVERAGE. | | | 24.5.2.3 SIGNAL STRENGTH. | | | 24.5.2.3.1 INBOUND. A MINIMUM INBOUND SIGNAL STRENGTH | | | OF -95 DBM, OR OTHER SIGNAL STRENGTH AS REQUIRED BY THE | | | AUTHORITY HAVING JURISDICTION, SHALL BE PROVIDED | | | THROUGHOUT THE COVERAGE AREA. | | | 24.5.2.3.2 OUTBOUND. A MINIMUM OUTBOUND SIGNAL STRENGTH | | | OF -95 DBM AT THE DONOR SITE, OR OTHER SIGNAL STRENGTH | | | AS REQUIRED BY THE AUTHORITY HAVING JURISDICTION, SHALL | | | BE PROVIDED FROM THE COVERAGE AREA. | | | | | | THE SYSTEM SHALL MAINTAIN A MINIMUM RADIO SIGNAL | | | STRENGTH OF -95 DBM FOR THE RADIO SYSTEM USED BY WEST | | | PALM BEACH FIRE RESCUE. TESTING SHALL BE BY AN | | | ACCEPTABLE NATIONAL STANDARD DOCUMENTING PERCENTAGES | | | NOTED ABOVE AND BY ACTUAL RADIO TESTING BY FIRE | | | PERSONNEL. IF THE MINIMUM CANNOT BE MAINTAINED, A | | | BI-DIRECTIONAL AMPLIFIED SYSTEM SHALL BE INSTALLED WITH | | | A MINIMUM 2-HOUR RUN TIME BATTERY BACK-UP. | | | | | | PLEASE CONTACT MARK FILLA, PALM BEACH COUNTY PUBLIC | | | SAFETY RADIO SYSTEMS MANAGER, AS OUR RADIOS OPERATE ON | | | THEIR SYSTEM FOR DETAILED RADIO FREQUENCY AND | | | INSTALLATION INSTRUCTIONS. | | | | | | | | | 14. KNOX-BOX KEY SYSTEM SHALL BE REQUIRED FOR THIS | | | BUILDING. | | | | | | ANY GATES SHALL BE PROVIDED WITH KNOX KEY ACCESS LOCKS, | | | PADLOCKS AND/OR SWITCHES FOR 24 HOUR EMERGENCY ACCESS. | | | | | | 15. THE SMOKE CONTROL SYSTEM SHALL COMPLY WITH NFPA | | | 101, CHAPTER 9, BUILDING SERVICE AND FIRE PROTECTION | | | EQUIPMENT, INCLUDING: | | | | | | THE SMOKE CONTROL SYSTEMS SHALL BE INSTALLED, | | | INSPECTED, TESTED, AND MAINTAINED IN ACCORDANCE WITH | | | NFPA 92, STANDARD FOR SMOKE CONTROL SYSTEMS; NFPA 204, | | | STANDARD FOR SMOKE AND HEAT VENTING; OR NATIONALLY | | | RECOGNIZED STANDARDS, ENGINEERING GUIDES, OR | | | RECOMMENDED PRACTICES, AS APPROVED BY THE AUTHORITY | | | HAVING JURISDICTION. | | | | | | THE ENGINEER OF RECORD SHALL CLEARLY IDENTIFY THE | | | INTENT OF THE SYSTEM, THE DESIGN METHOD USED, THE | | | APPROPRIATENESS OF THE METHOD USED, AND THE REQUIRED | | | MEANS OF INSPECTING, TESTING, AND MAINTAINING THE | | | SYSTEM. | | | | | | ACCEPTANCE TESTING SHALL BE PERFORMED BY A SPECIAL | | | INSPECTOR IN ACCORDANCE WITH SECTION 9.9. | | | | | | 16. THE BUREAU'S APPROVAL OF THIS SUBMITTED PROJECT | | | DOES NOT CONSTITUTE IT'S FINAL REVIEW OR APPROVAL. | | | | | | 17. THE BUREAU SHALL REVIEW ALL SUBMITTED BUILDING | | | PLANS AT THE APPROPRIATE TIME AND IN ACCORDANCE WITH | | | THE REQUIREMENTS OF ALL APPLICABLE CODES AND STANDARDS. | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
5 |
Status |
P |
Date |
03-29-2021 |
|
|
Cont ID |
|
| Sent By |
rcaranci |
Date |
04-12-2021 |
Time |
11:41 |
Rev Time |
0.00 |
| Received By |
rcaranci |
Date |
03-29-2021 |
Time |
11:40 |
Sent To |
|
|
| Notes |
| 2021-04-12 11:41:54 | FROM: RAY CARANCI, SENIOR LANDSCAPE PLANNER | | | 561-822-1462 | | | PROJECT: 350 N AUSTRALIAN Z20080008 | | | MARCH 29, 2021 | | | I HAVE REVIEWED THE ABOVE REFERENCED PETITION, AND | | | PROVIDE THE FOLLOWING COMMENTS: | | | | | | 1. SATISFIED. PROVIDE A COMPLETE TREE SURVEY THAT | | | INCLUDES ALL AFFECTED AREAS INCLUDING PAVEMENT OR | | | PARKING MODIFICATIONS TO THE ADJACENT PROPERTY. | | | THE ADDITIONAL AREAS FOR THE TREE SURVEY HAVE NOT BEEN | | | INCLUDED. | | | | | | 2. SATISFIED. PROVIDE A TREE DISPOSITION LIST AND PLAN. | | | TREE DISPOSITION IS STILL MISSING EXISTING TREES. | | | | | | 3. SATISFIED. SECTION 94-448 (D)(3) REQUIRES NATIVE | | | TREES IN GOOD CONDITION TO BE PRESERVED ON SITE OR | | | RELOCATED. ANSI A 300 (PART 5) STANDARDS SPECIFY | | | EXAMPLES OF SUITABILITY RATINGS OF GOOD, MODERATE, OR | | | POOR FOR RELOCATION. PROVIDE CONDITION FOR ALL TREES | | | AND RELOCATION POTENTIAL FOR THE NATIVE TREES AND | | | PALMS. | | | ALL TREES NEED TO BE INCLUDED, AND AN ACCURATE REASON | | | FOR REMOVAL PROVIDED. THE EXISTING LIVE OAKS CAN BE | | | EITHER PRESERVED IN PLACE OR RELOCATED TO CITY | | | PROPERTY. | | | | | | | | | 4. SATISFIED. PROVIDE A DIAGRAM OF THE REQUIRED AND | | | PROVIDED PUBLIC AND PRIVATE OPEN SPACE AREAS FOR CLD 25 | | | ZONING DISTRICT. IDENTIFY THE TYPE OF OPEN SPACE AS | | | ALLOWED BY TABLE IV-7 AND DEFINITIONS IN SECTION | | | 94-109. SHOW HOW THE STANDARDS FOR THE TYPES OF OPEN | | | SPACE ARE MET FOR VEGETATED AREAS AND TREE CANOPY | | | SQUARE FOOTAGE BASED ON TABLE IV-8. | | | THE REQUIRED PRIVATE OPEN SPACE NEEDS TO BE QUANTIFIED, | | | IDENTIFIED AS TO THE TYPE, AND ALL REQUIREMENTS NEED TO | | | BE SHOWN FOR THAT OPEN SPACE TYPE. THE ROOFTOP AREA | | | WITH THE POOL WOULD BE ROOFTOP GARDEN. THE PUBLIC OPEN | | | SPACE NEEDS TO BE IDENTIFIED AS A TYPE THAT FITS, | | | PROBABLY GARDEN PLAZA, AND THE REQUIREMENTS SHOWN. | | | | | | FOR THE PRIVATE OPEN SPACE ROOFTOP GARDEN CORRECT THE | | | TREE CANOPY SQUARE FOOTAGE FOR TREE TYPES BASED ON | | | TABLE IV-8. | | | PROVIDE THE DETAILS ON THE PLANT LIST AND TREE CANOPY | | | CREDITS FOR THE PUBLIC OPEN SPACE. | | | | | | 5. SATISFIED. ADD RELOCATED TREES OR PALMS TO THE PLANT | | | LIST AND COUNT THEM TOWARD THE REQUIRED TREES. | | | TREE SURVEY AND TREE DISPOSITION NEED TO BE COMPLETED. | | | | | | 6. SATISFIED. PROVIDE CALCULATIONS FOR REQUIRED STREET | | | TREES AT ONE FOR EVERY 30 FEET OR PORTION THEREOF FOR | | | STREETSCAPE LENGTH, AND SHOW THE NUMBER PROVIDED PER | | | SECTION 94-113 AND 94-116. | | | STREET TREE CALCULATIONS AND PLAN NEED TO BE PROVIDED. | | | | | | 7. SATISFIED. THERE APPEAR TO BE CONFLICTS IN SEVERAL | | | LOCATIONS BETWEEN EXISTING TREES AND WATER AND SEWER | | | LINES ON THE LANDSCAPE PLAN. ADJUST LOCATIONS OF | | | UTILITY LINES TO RESOLVE CONFLICTS WITH EXISTING TREES | | | AND LANDSCAPING IN THE OPEN SPACE. THE REQUIRED STREET | | | TREES PROPOSED ALONG CLEARWATER ARE IN CONFLICT WITH AN | | | EXISTING SEWER LINE. | | | FROM THE ACTUAL UTILITY LOCATIONS, THERE IS A WATER | | | LINE THAT WOULD CONFLICT WITH THE STREET TREE LOCATIONS | | | THAT WOULD HAVE TO BE RELOCATED ALSO. | | | | | | 8. SATISFIED. PROVIDE A COMPLETE PLANT LIST. | | | PLANT LIST NEEDS TO BE MODIFIED TO SEPARATE THE | | | REQUIRED OPEN SPACE PLANT LISTS. | | | | | | | | | 9. SATISFIED. REMOVE HIGHRISE CULTIVAR AND INDICATE | | | SPECIES LIVE OAK. | | | | | | 10. SATISFIED. PROVIDE THE 50 REQUIRED FLORIDA FRIENDLY | | | POINTS BASED ON THE FINAL PLANT LIST PER SECTION | | | 94-443(G). | | | REVISE AFTER ALL CHANGES ARE COMPLETE WITH LANDSCAPE | | | PLAN. 6A. DOES NOT QUALIFY. | | | PROVIDE ANY JUSTIFICATION FOR 6A.OR PROVIDE OTHER | | | POINTS. | | | | | | 11. SATISFIED. SHOW COMPLIANCE WITH SECTION 94-445 L. | | | PLANT SPECIES. A MINIMUM OF 60 PERCENT OF PLANT | | | MATERIAL ADDED SHALL BE FLORIDA NATIVE OR DROUGHT | | | TOLERANT SPECIES SELECTED FROM THE CITY LIST OR THE | | | LIST OF SPECIES IN THE MOST RECENT EDITION OF SOUTH | | | FLORIDA WATER MANAGEMENT DISTRICT WATERWISE SOUTH | | | FLORIDA LANDSCAPES. PROVIDE THE ACTUAL PERCENTAGE BASED | | | ON THE PLANT LIST. | | | REVISE AFTER ALL CHANGES ARE COMPLETE WITH LANDSCAPE | | | PLAN. | | | | | | ADDITIONAL COMMENTS 11/4/20: | | | | | | 12. SATISFIED. THE TWO LIVE OAK TREES K AND L SHOULD BE | | | PRESERVED, AND THE PLAZA DESIGNED AROUND THEM | | | | | | 13. SATISFIED. THERE ARE LIVE OAK TREES THAT ARE IN | | | CONFLICT WITH EXISTING ABOVE GROUND UTILITY VALVES. | | | THIS NEEDS TO BE ADDRESSED IF THE VALVE LOCATIONS ARE | | | NOT BEING MODIFIED. | | | | | | 14. SATISFIED. OPEN SPACE CALCULATIONS FOR REQUIRED | | | TREES NEED TO BE SEPARATED FROM THE REQUIRED PUBLIC AND | | | PRIVATE OPEN SPACE AREAS. | | | | | | 15. SATISFIED. PROVIDE BUFFER REQUIREMENTS ON THE CHART | | | FOR THE SOUTHERN AREAS OF THE LOT ADJACENT TO PROPERTY | | | LINES. | | | | | | 16. SATISFIED. ANY NEW PARKING CREATED MUST MEET THE | | | REQUIREMENTS OF SECTION 94-443(C)(3) A. INCLUDING | | | TERMINAL LANDSCAPE ISLANDS. THE CONFLICT WITH THE | | | RELOCATED HYDRANT AND THE PROPOSED OAK TREE ADJACENT TO | | | THE PROPOSED PARKING. | | | | | | ADDITIONAL COMMENTS 3/23/21: | | | | | | 17. MAKE THE FOLLOWING CORRECTIONS TO THE TREE | | | DISPOSITION PLAN: | | | ? SATISFIED. THE TREE DISPOSITION PLAN NEEDS TO FOLLOW | | | WEST PALM BEACH CODE SECTION 94-448, REMOVE REFERENCES | | | TO OTHER COUNTY(?) CODES. | | | ? SATISFIED. REMOVE COCOPLUM FROM LIST, AS IT IS NOT | | | CLASSIFIED AS A TREE. | | | ? SATISFIED. ADD A COLUMN TO THE CHART FOR MITIGATION | | | SQUARE FOOTAGE DUE | | | ? SATISFIED. WASHINGTONIA PALMS ARE CATEGORY 4 AND ARE | | | 50 SQ FT MITIGATION DUE. | | | ? SATISFIED. ROYAL PALMS ARE CATEGORY 3 AND ARE 100 SQ | | | FT MITIGATION DUE. | | | ? SATISFIED. OLEANDER IS CATEGORY 3 AND IS 100 SQ FT | | | MITIGATION DUE. | | | ? SATISFIED. PROVIDE TOTAL OF MITIGATION SQUARE FOOTAGE | | | DUE. | | | ? SATISFIED. PROVIDE A TOTAL OF MITIGATION SQUARE | | | FOOTAGE PROVIDED BASED ON THE PLANT LIST. | | | | | | 18. SATISFIED. THERE IS STILL A CONFLICT WITH THE LIVE | | | OAK TREE, THE SEWER LINE AND THE FDC ON THE SOUTH SIDE | | | OF PROPOSED PARKING. A PARKING SPACE MAY HAVE TO BE | | | CONVERTED TO LANDSCAPE AREA TO RESOLVE THE CONFLICT. | | | 19. SATISFIED. STREET TREES NEED TO BE SHOWN LOCATED | | | BETWEEN THE BACK OF CURB AND SIDEWALK IN THE PLANTING | | | STRIP. | | | 20. SATISFIED. PROVIDE SCREENING HEDGES FOR ALL GROUND | | | MOUNTED VALVES AND EQUIPMENT AND ADD A NOTE THAT ALL | | | EQUIPMENT WILL BE SCREENED. | | | CONDITIONS OF APPROVAL | | | 1. PRIOR TO THE REMOVAL OR RELOCATION OF ANY TREES ON | | | THE PROPERTY, A TREE ALTERATION PERMIT SHALL BE | | | SUBMITTED, REVIEWED AND APPROVED BY THE DEVELOPMENT | | | SERVICES DEPARTMENT, PLANNING DIVISION. | | | |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
4 |
Status |
F |
Date |
03-23-2021 |
|
|
Cont ID |
|
| Sent By |
rcaranci |
Date |
03-23-2021 |
Time |
15:30 |
Rev Time |
0.00 |
| Received By |
rcaranci |
Date |
03-23-2021 |
Time |
15:30 |
Sent To |
|
|
| Notes |
| 2021-03-23 15:31:14 | FROM: RAY CARANCI, SENIOR LANDSCAPE PLANNER | | | 561-822-1462 | | | PROJECT: 350 N AUSTRALIAN Z20080008 | | | MARCH 23, 2021 | | | I HAVE REVIEWED THE ABOVE REFERENCED PETITION, AND | | | PROVIDE THE FOLLOWING COMMENTS: | | | | | | 1. SATISFIED. PROVIDE A COMPLETE TREE SURVEY THAT | | | INCLUDES ALL AFFECTED AREAS INCLUDING PAVEMENT OR | | | PARKING MODIFICATIONS TO THE ADJACENT PROPERTY. | | | THE ADDITIONAL AREAS FOR THE TREE SURVEY HAVE NOT BEEN | | | INCLUDED. | | | | | | 2. SATISFIED. PROVIDE A TREE DISPOSITION LIST AND PLAN. | | | TREE DISPOSITION IS STILL MISSING EXISTING TREES. | | | | | | 3. SATISFIED. SECTION 94-448 (D)(3) REQUIRES NATIVE | | | TREES IN GOOD CONDITION TO BE PRESERVED ON SITE OR | | | RELOCATED. ANSI A 300 (PART 5) STANDARDS SPECIFY | | | EXAMPLES OF SUITABILITY RATINGS OF GOOD, MODERATE, OR | | | POOR FOR RELOCATION. PROVIDE CONDITION FOR ALL TREES | | | AND RELOCATION POTENTIAL FOR THE NATIVE TREES AND | | | PALMS. | | | ALL TREES NEED TO BE INCLUDED, AND AN ACCURATE REASON | | | FOR REMOVAL PROVIDED. THE EXISTING LIVE OAKS CAN BE | | | EITHER PRESERVED IN PLACE OR RELOCATED TO CITY | | | PROPERTY. | | | | | | | | | 4. PARTIALLY SATISFIED. PROVIDE A DIAGRAM OF THE | | | REQUIRED AND PROVIDED PUBLIC AND PRIVATE OPEN SPACE | | | AREAS FOR CLD 25 ZONING DISTRICT. IDENTIFY THE TYPE OF | | | OPEN SPACE AS ALLOWED BY TABLE IV-7 AND DEFINITIONS IN | | | SECTION 94-109. SHOW HOW THE STANDARDS FOR THE TYPES OF | | | OPEN SPACE ARE MET FOR VEGETATED AREAS AND TREE CANOPY | | | SQUARE FOOTAGE BASED ON TABLE IV-8. | | | THE REQUIRED PRIVATE OPEN SPACE NEEDS TO BE QUANTIFIED, | | | IDENTIFIED AS TO THE TYPE, AND ALL REQUIREMENTS NEED TO | | | BE SHOWN FOR THAT OPEN SPACE TYPE. THE ROOFTOP AREA | | | WITH THE POOL WOULD BE ROOFTOP GARDEN. THE PUBLIC OPEN | | | SPACE NEEDS TO BE IDENTIFIED AS A TYPE THAT FITS, | | | PROBABLY GARDEN PLAZA, AND THE REQUIREMENTS SHOWN. | | | | | | FOR THE PRIVATE OPEN SPACE ROOFTOP GARDEN CORRECT THE | | | TREE CANOPY SQUARE FOOTAGE FOR TREE TYPES BASED ON | | | TABLE IV-8. | | | PROVIDE THE DETAILS ON THE PLANT LIST AND TREE CANOPY | | | CREDITS FOR THE PUBLIC OPEN SPACE. | | | | | | 5. SATISFIED. ADD RELOCATED TREES OR PALMS TO THE PLANT | | | LIST AND COUNT THEM TOWARD THE REQUIRED TREES. | | | TREE SURVEY AND TREE DISPOSITION NEED TO BE COMPLETED. | | | | | | 6. SATISFIED. PROVIDE CALCULATIONS FOR REQUIRED STREET | | | TREES AT ONE FOR EVERY 30 FEET OR PORTION THEREOF FOR | | | STREETSCAPE LENGTH, AND SHOW THE NUMBER PROVIDED PER | | | SECTION 94-113 AND 94-116. | | | STREET TREE CALCULATIONS AND PLAN NEED TO BE PROVIDED. | | | | | | 7. SATISFIED. THERE APPEAR TO BE CONFLICTS IN SEVERAL | | | LOCATIONS BETWEEN EXISTING TREES AND WATER AND SEWER | | | LINES ON THE LANDSCAPE PLAN. ADJUST LOCATIONS OF | | | UTILITY LINES TO RESOLVE CONFLICTS WITH EXISTING TREES | | | AND LANDSCAPING IN THE OPEN SPACE. THE REQUIRED STREET | | | TREES PROPOSED ALONG CLEARWATER ARE IN CONFLICT WITH AN | | | EXISTING SEWER LINE. | | | FROM THE ACTUAL UTILITY LOCATIONS, THERE IS A WATER | | | LINE THAT WOULD CONFLICT WITH THE STREET TREE LOCATIONS | | | THAT WOULD HAVE TO BE RELOCATED ALSO. | | | | | | 8. SATISFIED. PROVIDE A COMPLETE PLANT LIST. | | | PLANT LIST NEEDS TO BE MODIFIED TO SEPARATE THE | | | REQUIRED OPEN SPACE PLANT LISTS. | | | | | | | | | 9. SATISFIED. REMOVE HIGHRISE CULTIVAR AND INDICATE | | | SPECIES LIVE OAK. | | | | | | 10. PARTIALLY SATISFIED. PROVIDE THE 50 REQUIRED | | | FLORIDA FRIENDLY POINTS BASED ON THE FINAL PLANT LIST | | | PER SECTION 94-443(G). | | | REVISE AFTER ALL CHANGES ARE COMPLETE WITH LANDSCAPE | | | PLAN. 6A. DOES NOT QUALIFY. | | | PROVIDE ANY JUSTIFICATION FOR 6A.OR PROVIDE OTHER | | | POINTS. | | | | | | 11. SATISFIED. SHOW COMPLIANCE WITH SECTION 94-445 L. | | | PLANT SPECIES. A MINIMUM OF 60 PERCENT OF PLANT | | | MATERIAL ADDED SHALL BE FLORIDA NATIVE OR DROUGHT | | | TOLERANT SPECIES SELECTED FROM THE CITY LIST OR THE | | | LIST OF SPECIES IN THE MOST RECENT EDITION OF SOUTH | | | FLORIDA WATER MANAGEMENT DISTRICT WATERWISE SOUTH | | | FLORIDA LANDSCAPES. PROVIDE THE ACTUAL PERCENTAGE BASED | | | ON THE PLANT LIST. | | | REVISE AFTER ALL CHANGES ARE COMPLETE WITH LANDSCAPE | | | PLAN. | | | | | | ADDITIONAL COMMENTS 11/4/20: | | | | | | 12. SATISFIED. THE TWO LIVE OAK TREES K AND L SHOULD BE | | | PRESERVED, AND THE PLAZA DESIGNED AROUND THEM | | | | | | 13. SATISFIED. THERE ARE LIVE OAK TREES THAT ARE IN | | | CONFLICT WITH EXISTING ABOVE GROUND UTILITY VALVES. | | | THIS NEEDS TO BE ADDRESSED IF THE VALVE LOCATIONS ARE | | | NOT BEING MODIFIED. | | | | | | 14. SATISFIED. OPEN SPACE CALCULATIONS FOR REQUIRED | | | TREES NEED TO BE SEPARATED FROM THE REQUIRED PUBLIC AND | | | PRIVATE OPEN SPACE AREAS. | | | | | | 15. SATISFIED. PROVIDE BUFFER REQUIREMENTS ON THE CHART | | | FOR THE SOUTHERN AREAS OF THE LOT ADJACENT TO PROPERTY | | | LINES. | | | | | | 16. SATISFIED. ANY NEW PARKING CREATED MUST MEET THE | | | REQUIREMENTS OF SECTION 94-443(C)(3) A. INCLUDING | | | TERMINAL LANDSCAPE ISLANDS. THE CONFLICT WITH THE | | | RELOCATED HYDRANT AND THE PROPOSED OAK TREE ADJACENT TO | | | THE PROPOSED PARKING. | | | | | | ADDITIONAL COMMENTS 4/23/21: | | | | | | 17. MAKE THE FOLLOWING CORRECTIONS TO THE TREE | | | DISPOSITION PLAN: | | | ? THE TREE DISPOSITION PLAN NEEDS TO FOLLOW WEST PALM | | | BEACH CODE SECTION 94-448, REMOVE REFERENCES TO OTHER | | | COUNTY(?) CODES. | | | ? REMOVE COCOPLUM FROM LIST, AS IT IS NOT CLASSIFIED AS | | | A TREE. | | | ? ADD A COLUMN TO THE CHART FOR MITIGATION SQUARE | | | FOOTAGE DUE | | | ? WASHINGTONIA PALMS ARE CATEGORY 4 AND ARE 50 SQ FT | | | MITIGATION DUE. | | | ? ROYAL PALMS ARE CATEGORY 3 AND ARE 100 SQ FT | | | MITIGATION DUE. | | | ? OLEANDER IS CATEGORY 2 AND IS 100 SQ FT MITIGATION | | | DUE. | | | ? PROVIDE TOTAL OF MITIGATION SQUARE FOOTAGE DUE. | | | ? PROVIDE A TOTAL OF MITIGATION SQUARE FOOTAGE PROVIDED | | | BASED ON THE PLANT LIST. | | | | | | 18. THERE IS STILL A CONFLICT WITH THE LIVE OAK TREE, | | | THE SEWER LINE AND THE FDC ON THE SOUTH SIDE OF | | | PROPOSED PARKING. A PARKING SPACE MAY HAVE TO BE | | | CONVERTED TO LANDSCAPE AREA TO RESOLVE THE CONFLICT. | | | 19. STREET TREES NEED TO BE SHOWN LOCATED BETWEEN THE | | | BACK OF CURB AND SIDEWALK IN THE PLANTING STRIP. | | | 20. PROVIDE SCREENING HEDGES FOR ALL GROUND MOUNTED | | | VALVES AND EQUIPMENT AND ADD A NOTE THAT ALL EQUIPMENT | | | WILL BE SCREENED. | | | CONDITIONS OF APPROVAL | | | 1. PRIOR TO THE REMOVAL OR RELOCATION OF ANY TREES ON | | | THE PROPERTY, A TREE ALTERATION PERMIT SHALL BE | | | SUBMITTED, REVIEWED AND APPROVED BY THE DEVELOPMENT | | | SERVICES DEPARTMENT, PLANNING DIVISION. | | | |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
3 |
Status |
F |
Date |
03-23-2021 |
|
|
Cont ID |
|
| Sent By |
rcaranci |
Date |
03-23-2021 |
Time |
14:02 |
Rev Time |
0.00 |
| Received By |
rcaranci |
Date |
03-23-2021 |
Time |
14:02 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
2 |
Status |
F |
Date |
11-04-2020 |
|
|
Cont ID |
|
| Sent By |
rcaranci |
Date |
11-04-2020 |
Time |
16:40 |
Rev Time |
0.00 |
| Received By |
rcaranci |
Date |
11-04-2020 |
Time |
16:40 |
Sent To |
|
|
| Notes |
| 2020-11-04 16:41:13 | FROM: RAY CARANCI, SENIOR LANDSCAPE PLANNER | | | 561-822-1462 | | | PROJECT: 350 N AUSTRALIAN Z20080008 | | | NOVEMBER 4, 2020 | | | I HAVE REVIEWED THE ABOVE REFERENCED PETITION, AND | | | PROVIDE THE FOLLOWING COMMENTS: | | | | | | 1. NOT SATISFIED. PROVIDE A COMPLETE TREE SURVEY THAT | | | INCLUDES ALL AFFECTED AREAS INCLUDING PAVEMENT OR | | | PARKING MODIFICATIONS TO THE ADJACENT PROPERTY. | | | THE ADDITIONAL AREAS FOR THE TREE SURVEY HAVE NOT BEEN | | | INCLUDED. | | | | | | 2. PARTIALLY SATISFIED. PROVIDE A TREE DISPOSITION LIST | | | AND PLAN. | | | TREE DISPOSITION IS STILL MISSING EXISTING TREES. | | | | | | 3. PARTIALLY SATISFIED. SECTION 94-448 (D)(3) REQUIRES | | | NATIVE TREES IN GOOD CONDITION TO BE PRESERVED ON SITE | | | OR RELOCATED. ANSI A 300 (PART 5) STANDARDS SPECIFY | | | EXAMPLES OF SUITABILITY RATINGS OF GOOD, MODERATE, OR | | | POOR FOR RELOCATION. PROVIDE CONDITION FOR ALL TREES | | | AND RELOCATION POTENTIAL FOR THE NATIVE TREES AND | | | PALMS. | | | ALL TREES NEED TO BE INCLUDED, AND AN ACCURATE REASON | | | FOR REMOVAL PROVIDED. THE EXISTING LIVE OAKS CAN BE | | | EITHER PRESERVED IN PLACE OR RELOCATED TO CITY | | | PROPERTY. | | | | | | | | | 4. PARTIALLY SATISFIED. PROVIDE A DIAGRAM OF THE | | | REQUIRED AND PROVIDED PUBLIC AND PRIVATE OPEN SPACE | | | AREAS FOR CLD 25 ZONING DISTRICT. IDENTIFY THE TYPE OF | | | OPEN SPACE AS ALLOWED BY TABLE IV-7 AND DEFINITIONS IN | | | SECTION 94-109. SHOW HOW THE STANDARDS FOR THE TYPES OF | | | OPEN SPACE ARE MET FOR VEGETATED AREAS AND TREE CANOPY | | | SQUARE FOOTAGE BASED ON TABLE IV-8. | | | THE REQUIRED PRIVATE OPEN SPACE NEEDS TO BE QUANTIFIED, | | | IDENTIFIED AS TO THE TYPE, AND ALL REQUIREMENTS NEED TO | | | BE SHOWN FOR THAT OPEN SPACE TYPE. THE ROOFTOP AREA | | | WITH THE POOL WOULD BE ROOFTOP GARDEN. THE PUBLIC OPEN | | | SPACE NEEDS TO BE IDENTIFIED AS A TYPE THAT FITS, | | | PROBABLY GARDEN PLAZA, AND THE REQUIREMENTS SHOWN. | | | | | | | | | 5. NOT SATISFIED. ADD RELOCATED TREES OR PALMS TO THE | | | PLANT LIST AND COUNT THEM TOWARD THE REQUIRED TREES. | | | TREE SURVEY AND TREE DISPOSITION NEED TO BE COMPLETED. | | | | | | 6. NOT SATISFIED. PROVIDE CALCULATIONS FOR REQUIRED | | | STREET TREES AT ONE FOR EVERY 30 FEET OR PORTION | | | THEREOF FOR STREETSCAPE LENGTH, AND SHOW THE NUMBER | | | PROVIDED PER SECTION 94-113 AND 94-116. | | | STREET TREE CALCULATIONS AND PLAN NEED TO BE PROVIDED. | | | | | | 7. PARTIALLY SATISFIED. THERE APPEAR TO BE CONFLICTS IN | | | SEVERAL LOCATIONS BETWEEN EXISTING TREES AND WATER AND | | | SEWER LINES ON THE LANDSCAPE PLAN. ADJUST LOCATIONS OF | | | UTILITY LINES TO RESOLVE CONFLICTS WITH EXISTING TREES | | | AND LANDSCAPING IN THE OPEN SPACE. THE REQUIRED STREET | | | TREES PROPOSED ALONG CLEARWATER ARE IN CONFLICT WITH AN | | | EXISTING SEWER LINE. | | | FROM THE ACTUAL UTILITY LOCATIONS, THERE IS A WATER | | | LINE THAT WOULD CONFLICT WITH THE STREET TREE LOCATIONS | | | THAT WOULD HAVE TO BE RELOCATED ALSO. | | | | | | 8. PARTIALLY SATISFIED. PROVIDE A COMPLETE PLANT LIST. | | | PLANT LIST NEEDS TO BE MODIFIED TO SEPARATE THE | | | REQUIRED OPEN SPACE PLANT LISTS. | | | | | | | | | 9. SATISFIED. REMOVE HIGHRISE CULTIVAR AND INDICATE | | | SPECIES LIVE OAK. | | | | | | 10. PARTIALLY SATISFIED. PROVIDE THE 50 REQUIRED | | | FLORIDA FRIENDLY POINTS BASED ON THE FINAL PLANT LIST | | | PER SECTION 94-443(G). | | | REVISE AFTER ALL CHANGES ARE COMPLETE WITH LANDSCAPE | | | PLAN. 6A. DOES NOT QUALIFY. | | | | | | | | | 11. PARTIALLY SATISFIED. SHOW COMPLIANCE WITH SECTION | | | 94-445 L. PLANT SPECIES. A MINIMUM OF 60 PERCENT OF | | | PLANT MATERIAL ADDED SHALL BE FLORIDA NATIVE OR DROUGHT | | | TOLERANT SPECIES SELECTED FROM THE CITY LIST OR THE | | | LIST OF SPECIES IN THE MOST RECENT EDITION OF SOUTH | | | FLORIDA WATER MANAGEMENT DISTRICT WATERWISE SOUTH | | | FLORIDA LANDSCAPES. PROVIDE THE ACTUAL PERCENTAGE BASED | | | ON THE PLANT LIST. | | | REVISE AFTER ALL CHANGES ARE COMPLETE WITH LANDSCAPE | | | PLAN. | | | | | | ADDITIONAL COMMENTS 11/4/20: | | | | | | 12. THE TWO LIVE OAK TREES K AND L SHOULD BE PRESERVED, | | | AND THE PLAZA DESIGNED AROUND THEM | | | | | | 13. THERE ARE LIVE OAK TREES THAT ARE IN CONFLICT WITH | | | EXISTING ABOVE GROUND UTILITY VALVES. THIS NEEDS TO BE | | | ADDRESSED IF THE VALVE LOCATIONS ARE NOT BEING | | | MODIFIED. | | | | | | 14. OPEN SPACE CALCULATIONS FOR REQUIRED TREES NEED TO | | | BE SEPARATED FROM THE REQUIRED PUBLIC AND PRIVATE OPEN | | | SPACE AREAS. | | | | | | 15. PROVIDE BUFFER REQUIREMENTS ON THE CHART FOR THE | | | SOUTHERN AREAS OF THE LOT ADJACENT TO PROPERTY LINES. | | | | | | 16. ANY NEW PARKING CREATED MUST MEET THE REQUIREMENTS | | | OF SECTION 94-443(C)(3) A. INCLUDING TERMINAL LANDSCAPE | | | ISLANDS. THE CONFLICT WITH THE RELOCATED HYDRANT AND | | | THE PROPOSED OAK TREE ADJACENT TO THE PROPOSED PARKING. | | | CONDITIONS OF APPROVAL | | | 1. PRIOR TO THE REMOVAL OR RELOCATION OF ANY TREES ON | | | THE PROPERTY, A TREE ALTERATION PERMIT SHALL BE | | | SUBMITTED, REVIEWED AND APPROVED BY THE DEVELOPMENT | | | SERVICES DEPARTMENT, PLANNING DIVISION. | | | |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
1 |
Status |
F |
Date |
09-08-2020 |
|
|
Cont ID |
|
| Sent By |
rcaranci |
Date |
09-08-2020 |
Time |
13:19 |
Rev Time |
0.00 |
| Received By |
rcaranci |
Date |
09-08-2020 |
Time |
13:19 |
Sent To |
|
|
| Notes |
| 2020-09-08 13:19:29 | FROM: RAY CARANCI, SENIOR LANDSCAPE PLANNER | | | 561-822-1462 | | | PROJECT: 350 N AUSTRALIAN Z20080008 | | | SEPTEMBER 8, 2020 | | | I HAVE REVIEWED THE ABOVE REFERENCED PETITION, AND | | | PROVIDE THE FOLLOWING COMMENTS: | | | | | | 1. PROVIDE A COMPLETE TREE SURVEY THAT INCLUDES ALL | | | AFFECTED AREAS INCLUDING PAVEMENT OR PARKING | | | MODIFICATIONS TO THE ADJACENT PROPERTY. | | | 2. PROVIDE A TREE DISPOSITION LIST AND PLAN. | | | 3. SECTION 94-448 (D)(3) REQUIRES NATIVE TREES IN GOOD | | | CONDITION TO BE PRESERVED ON SITE OR RELOCATED. ANSI A | | | 300 (PART 5) STANDARDS SPECIFY EXAMPLES OF SUITABILITY | | | RATINGS OF GOOD, MODERATE, OR POOR FOR RELOCATION. | | | PROVIDE CONDITION FOR ALL TREES AND RELOCATION | | | POTENTIAL FOR THE NATIVE TREES AND PALMS. | | | 4. PROVIDE A DIAGRAM OF THE REQUIRED AND PROVIDED | | | PUBLIC AND PRIVATE OPEN SPACE AREAS FOR CLD 25 ZONING | | | DISTRICT. IDENTIFY THE TYPE OF OPEN SPACE AS ALLOWED BY | | | TABLE IV-7 AND DEFINITIONS IN SECTION 94-109. SHOW HOW | | | THE STANDARDS FOR THE TYPES OF OPEN SPACE ARE MET FOR | | | VEGETATED AREAS AND TREE CANOPY SQUARE FOOTAGE BASED ON | | | TABLE IV-8. | | | | | | 5. ADD RELOCATED TREES OR PALMS TO THE PLANT LIST AND | | | COUNT THEM TOWARD THE REQUIRED TREES. | | | | | | 6. PROVIDE CALCULATIONS FOR REQUIRED STREET TREES AT | | | ONE FOR EVERY 30 FEET OR PORTION THEREOF FOR | | | STREETSCAPE LENGTH, AND SHOW THE NUMBER PROVIDED PER | | | SECTION 94-113 AND 94-116. | | | | | | 7. THERE APPEAR TO BE CONFLICTS IN SEVERAL LOCATIONS | | | BETWEEN EXISTING TREES AND WATER AND SEWER LINES ON THE | | | LANDSCAPE PLAN. ADJUST LOCATIONS OF UTILITY LINES TO | | | RESOLVE CONFLICTS WITH EXISTING TREES AND LANDSCAPING | | | IN THE OPEN SPACE. THE REQUIRED STREET TREES PROPOSED | | | ALONG CLEARWATER ARE IN CONFLICT WITH AN EXISTING SEWER | | | LINE. | | | | | | 8. PROVIDE A COMPLETE PLANT LIST. | | | | | | 9. REMOVE HIGHRISE CULTIVAR AND INDICATE SPECIES LIVE | | | OAK. | | | | | | 10. PROVIDE THE 50 REQUIRED FLORIDA FRIENDLY POINTS | | | BASED ON THE FINAL PLANT LIST PER SECTION 94-443(G). | | | | | | 11. SHOW COMPLIANCE WITH SECTION 94-445 L. PLANT | | | SPECIES. A MINIMUM OF 60 PERCENT OF PLANT MATERIAL | | | ADDED SHALL BE FLORIDA NATIVE OR DROUGHT TOLERANT | | | SPECIES SELECTED FROM THE CITY LIST OR THE LIST OF | | | SPECIES IN THE MOST RECENT EDITION OF SOUTH FLORIDA | | | WATER MANAGEMENT DISTRICT WATERWISE SOUTH FLORIDA | | | LANDSCAPES. PROVIDE THE ACTUAL PERCENTAGE BASED ON THE | | | PLANT LIST. | | | | | | | | | | | | CONDITIONS OF APPROVAL | | | 1. PRIOR TO THE REMOVAL OR RELOCATION OF ANY TREES ON | | | THE PROPERTY, A TREE ALTERATION PERMIT SHALL BE | | | SUBMITTED, REVIEWED AND APPROVED BY THE DEVELOPMENT | | | SERVICES DEPARTMENT, PLANNING DIVISION. | | | |
|
|
| Review Stop |
PARK |
PARKING |
| Rev No |
1 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
|
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
POLICE |
POLICE |
| Rev No |
1 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
|
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
PW |
PUBLIC WORKS |
| Rev No |
2 |
Status |
P |
Date |
03-24-2021 |
|
|
Cont ID |
|
| Sent By |
|
Date |
03-24-2021 |
Time |
|
Rev Time |
0.00 |
| Received By |
|
Date |
03-24-2021 |
Time |
|
Sent To |
|
|
| Notes |
| 2021-03-24 10:50:03 | PASSED WITH A PROVISO.THE COMPACTORS CONTAINERS SHALL | | | BE FRONT LOAD TYPE IN ORDER TO BE SERVICED BY THE | | | CITY`S SANITATION COLLECTION FRONT LOADER VEHICLES. | | | | | | DEPT OF PUBLIC WORKS | | | MATT HEJAZI | | | [email protected] | | | 561-822-2045 |
|
|
| Review Stop |
PW |
PUBLIC WORKS |
| Rev No |
1 |
Status |
F |
Date |
09-08-2020 |
|
|
Cont ID |
|
| Sent By |
|
Date |
09-08-2020 |
Time |
|
Rev Time |
|
| Received By |
|
Date |
09-08-2020 |
Time |
|
Sent To |
|
|
| Notes |
| 2020-09-08 17:02:10 | PLEASE PROVIDE THE FOLLOWINGS: | | | 1- LOS (LEVEL OF SERVICE ANALYSIS) TO REFLECT THE SOLID | | | WASTE VOLUME PRODUCED ALONG WITH THE SIZE AND TYPE OF | | | THE CONTAINER (I.E. DUMPSTER/COMPACTOR) THAT WILL BE | | | UTILIZED THAT WILL BE UTILIZED FOR THE SANITATION | | | SERVICE. | | | 2- DUMPSTER ENCLOSURE DETAI, IF APPLICABLE. FOR A | | | FREESTANDING SITE DUMPSTER ENCLOSURE, THE ENCLOSURE | | | SHALL COMPLY WITH THE LATEST REVISION OF CITY OF WEST | | | PALM BEACH GENERAL CONSTRUCTION-GARBAGE ENCLOSURE | | | STANDARD, GC-7. | | | 3- AUTO TURN FOR THE SANITATION SERVICE, FRONT LOADER | | | TRUCK WITH THE FOLLOWING SPECS: | | | - TRUCK LENGTH: 35 FT | | | - TRUCK WIDTH: 11 FT | | | - TURNING RADIUS: | | | - SAE TURNING RADIUS: 32.5 FT | | | - CURB-TO-CURB DIAMETER: 74 FT | | | - WALL-TO-WALL DIAMETER: 86.3 FT | | | 4- DESIGNATED LOCATION FOR THE BULK ITEM PICK UP AND | | | RECYCLING CONTAINERS. | | | | | | MATT HEJAZI | | | DEPT. OF PUBLIC WORKS | | | [email protected] | | | 561-822-2045 | | | |
|
|
| Review Stop |
STORM |
STORMWATER |
| Rev No |
2 |
Status |
P |
Date |
04-06-2021 |
|
|
Cont ID |
|
| Sent By |
tward |
Date |
04-06-2021 |
Time |
11:00 |
Rev Time |
0.00 |
| Received By |
tward |
Date |
04-06-2021 |
Time |
11:42 |
Sent To |
|
|
| Notes |
| 2021-04-06 11:41:46 | THE FOLLOWING COMMENTS ARE FROM THE REVIEW OF THE | | | 3/31/2021 SUBMITTAL. THEY CAN BE ADDRESSED DURING | | | ENGINEERING PERMIT SUBMITTAL. | | | | | | 1. SHOW ON THE DEMOLITION PLAN, SHEET C-03, THE | | | EXISTING DRAINAGE PIPE CONNECTIONS FOR THE TWO CATCH | | | BASINS IN THE NORTHEAST AREA OF THE SITE. | | | | | | 2. THE PGD PLAN (SHEET C-04) CALLS OUT 8' X 10' | | | EXFILTRATION TRENCH BUT THE EXFILTRATION TRENCH DETAIL | | | ON SHEET C-06 SHOWS 10' X 6.5' TRENCH DIMENSIONS. | | | | | | 3. THE EXFILTRATION TRENCH DETAIL SHOWS A WEIR | | | ELEVATION OF 15.70 FT NAVD. | | | A. WHERE IS THIS WEIR LOCATED? | | | B. LOWEST FINISHED GRADE IS 16.10. SUGGEST USING | | | CRUSHED CONCRETE BASE INSTTEAD OF LIMEROCK BASE TO | | | CONTEND WITH POTENTIAL SATURATED BASE CONDITIONS. | | | C. THE PROPOSED FINISHED GRADE OF THE LAWN OVER THE | | | RAINTANKS IS SHOWN TO BE 16.50' NAVD. SHOULD THE | | | FINISHED GRADE BE A MINIMUM OF 1 FOOT ABOVE THE WEIR | | | ELEVATION? | | | | | | 4. ADD VERTICAL DATUM REFERENCE AND CONVERSION EQUATION | | | TO NGVD1929 ON EVERY SHEET WITH ELEVATION INFORMATION. | | | | | | 5. SHOW MINIMUM HORIZONTAL CLEARANCE BETWEEN S.S.M.H. | | | #4 AND THE 8" WATER MAIN TO THE NORTH AND NORTHWEST OF | | | THE STRUCTURE. | | | | | | 6. CHECK WITH LAURA LE, PUBLIC UTILITIES ENGINEERING, | | | WHETHER TO INCLUDE IN THE DESIGN OF THE PROPOSED | | | SANITARY SYSTEM ON CLEARWATER DRIVE THE 0.1' DROP | | | ACROSS THE MANHOLES AS INDICATED ON THE SEWER MANHOLE | | | DETAIL. | | | | | | 7. IF THE TRENCH CUT FOR THE PROPOSED 12" WATER MAIN IS | | | WITHIN THE NORTHBOUND LANE OF CLEARWATER DRIVE, THE | | | FULL WIDTH OF THE NORTHBOUND LAND WILL NEED TO BE | | | MILLED AND RE-SURFACED. | | | | | | 8. AVOID HAVING VALVE COVERS FALL WITHIN THE CURB AND | | | GUTTER. | | | | | | 9. THE EXISTING WATER MAIN WILL NEED TO BE PROPERLY | | | RESTRAINED DUE TO THE PIPE DEFLECTIONS AND VALVES. | | | | | | TRACY WARD, P.E. | | | SENIOR STORMWATER ENGINEER | | | ENGINEERING SERVICES DEPARTMENT | | | [email protected] | | | 561-494-1120 (O) | | | 561-351-0510 (M) | | | | | | |
|
|
| Review Stop |
STORM |
STORMWATER |
| Rev No |
1 |
Status |
F |
Date |
09-10-2020 |
|
|
Cont ID |
|
| Sent By |
tward |
Date |
09-10-2020 |
Time |
15:37 |
Rev Time |
0.00 |
| Received By |
tward |
Date |
09-10-2020 |
Time |
16:46 |
Sent To |
|
|
| Notes |
| 2020-09-10 16:38:11 | THIS IS A CONCEPTUAL LEVEL REVIEW. CONSTRUCTION LEVEL | | | DETAILS, DESIGN CALCULATIONS AND THE POLLUTION | | | PREVENTION PLAN WILL BE REVIEWED AS PART OF THE | | | ENGINEERING DEVELOPMENT APPROVAL AND BUILDING PERMIT | | | APPLICATION PROCESSES. | | | THE FOLLOWING COMMENTS MUST BE ADDRESSED PRIOR TO SITE | | | PLAN APPROVAL: | | | | | | 1. LIST THE VERTICAL DATUM CONVERSION BETWEEN NAVD1988 | | | AND NGVD1929 ON THE SURVEY. | | | | | | 2. CLEAN UP THE OVERLAPPING SPOT GRADES ON THE SURVEY. | | | | | | 3. ON THE CIVIL PLANS, LIST THE VERTICAL DATUM ON EVERY | | | SHEET THAT HAS ELEVATION DATA. | | | | | | 4. BE CONSISTENT IN THE VERTICAL DATUM BEING USED. THE | | | SURVEY IS USING NAVD1988. SHEETS C-02 AND C-03 LISTS | | | NGVD1929. SHEET C2-04 LISTS NAVD1988. IF USING | | | NAVD1988, THEN THE RELATIONSHIP BETWEEN NAVD1988 AND | | | NGVD1929 ALSO NEEDS TO BE LISTED ON THE SHEET. | | | | | | 5. USE THE LATEST CITY DETAILS. | | | | | | 6. THE SFWMD ERP MODIFICATION IS TO BE OBTAINED THROUGH | | | NORMAL PERMIT APPLICATION SUBMISSION AND REVIEW AND NOT | | | OBTAINED THROUGH THE SELF-CERTIFICATION PROCESS. | | | | | | 7. REMOVE THE DRIVEWAY APRON AND INSTALL TYPE F CURB & | | | GUTTER AND GREENSPACE BETWEEN THE SIDEWALK AND CURB. | | | REMOVE ADA MATS ON EITHER SIDE OF THE DRIVEWAY THAT IS | | | BEING REMOVED AND REPAIR THE SIDEWALK FLAGS. | | | | | | 8. DURING CONSTRUCTION, THE DEWATERING DRAWDOWN CURVE | | | CANNOT INTERSECT THE HYDROSTATIC SURFACE OF CLEAR LAKE. | | | | | | 9. SHOW THE FIRE HYDRANT ALONG CLEARWATER DRIVE ON THE | | | CIVIL AND LANDSCAPE PLANS. | | | | | | 10. NOTE, IN TIMES OF DROUGHT, SFWMD AND/OR THE CITY | | | MAY NOT ALLOW THE USE OF POTABLE WATER TO MAINTAIN THE | | | WATER LEVEL IN THE WET RETENTION AREA. | | | | | | 11. EXFILTRATION TRENCH IS PROPOSED WITHIN THE BUILDING | | | FOOT PRINT. THERE NEEDS TO BE SUFFICIENT VERTICAL | | | CLEARANCE FOR MAINTENANCE EQUIPMENT TO ACCESS AND CLEAN | | | THE DRAINAGE STRUCTURES. | | | | | | 12. THE EXILTRATION TRENCH WILL EVENTUALLY NEED TO BE | | | REHABILITATED OR REPLACED TO RE-ESTABLISH THE DRAINAGE | | | CAPACITY. DESIGN AND LOCATION OF THE EXFILTRATION | | | TRENCH SHOULD TAKE THIS INTO ACCOUNT. | | | | | | 13. SUGGEST ADDING DRAINAGE STRUCTURES (MANHOLES) AT | | | THE EAST AND SOUTH ENDS OF THE EXFILTRATION TRENCH | | | SYSTEM TO ALLOW TRAPPED AIR TO ESCAPE FROM THE SYSTEM. | | | | | | 14.MANHOLE LIDS HAVE BEEN KNOWN TO BE BLOWN OFF WHEN | | | HIGH RISE ROOF DRAINS ARE CONNECTED TO THE DRAINAGE | | | SYSTEM. CONSIDER USING A DEEP AND/OR HEAVY MANHOLE LID | | | TO MINIMIZE THIS OCCURANCE. | | | | | | 14. CONFIRM THE BOTTOM OF THE EXFILTRATION TRENCH WILL | | | BE 14 FEET BELOW FINISHED GRADE AS DEPICTED ON SHEET | | | C-04. | | | | | | 15. REPLACE THE SIDEWALK AT THE NEW DRIVEWAY LOCATION | | | WITH 6-INCH THICK CONCRETE. | | | | | | | | | THE FOLLOWING COMMENTS MUST BE ADDRESSED PRIOR TO | | | ISSUANCE OF CONSTRUCTION AUTHORIZATION INCLUDING | | | BUILDING PERMITS AND ENGINEERING DEVELOPMENT APPROVAL. | | | | | | 1. AN ENGINEERING DEVELOPMENT APPROVAL APPLICATION MAY | | | BE REQUIRED FROM THE ENGINEERING SERVICES DEPARTMENT. | | | | | | 2. EROSION CONTROL PLAN AND DETAILS TO BE SUBMITTED | | | WITH THE ENGINEERING PERMIT APPLICATION. | | | | | | 3.. PROVIDE SFWMD ERP PERMIT MODIFICATION. | | | | | | TRACY WARD, PE | | | SENIOR STORMWATER ENGINEER | | | ENGINEERING SERVICES DEPARTMENT | | | 561-494-1120 (O) | | | 561-351-0510 (M) | | | [email protected] | | | |
|
|
| Review Stop |
SURVEY |
SURVEYING |
| Rev No |
4 |
Status |
P |
Date |
05-18-2021 |
|
|
Cont ID |
|
| Sent By |
vnoel |
Date |
05-18-2021 |
Time |
08:51 |
Rev Time |
0.00 |
| Received By |
vnoel |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2021-05-18 08:54:33 | PASSED WITH CONDITIONS: | | | | | | 1. ABANDONED WATER AND SEWER TO BE REMOVED ON FINAL | | | ENG. PLANS. | | | 2. PROFILE TO BE INCLUDED ON FINAL ENG. PLANS. |
|
|
| Review Stop |
SURVEY |
SURVEYING |
| Rev No |
3 |
Status |
F |
Date |
03-26-2021 |
|
|
Cont ID |
|
| Sent By |
vnoel |
Date |
03-26-2021 |
Time |
09:21 |
Rev Time |
0.00 |
| Received By |
vnoel |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2021-03-26 09:42:39 | 1. ABANDONED WATER AND SEWER LINES WILL NEED TO BE | | | REMOVED, NOT GROUTED IN PLACE. | | | 2. PROFILE OF NEW WATER AND SEWER CAN WAIT TILL | | | ENGINEERING APPLICATION BUT IF ANY CONFLICTS ARISE THE | | | DEVELOPER WILL BE RESPONSIBLE FOR THE OTHER UTILITY | | | RELOCATION. | | | 3. CUSTOMER SERVICE ( MARK HURLEY ) WILL NEED TO | | | APPROVE NEW METER/BACKFLOW CONFIGURATION IN SE CORNER. | | | 4. PLEASE PROVIDE COPY OF CONSENT FROM MASTER | | | ASSOCIATION. |
|
|
| Review Stop |
SURVEY |
SURVEYING |
| Rev No |
2 |
Status |
F |
Date |
11-05-2020 |
|
|
Cont ID |
|
| Sent By |
vnoel |
Date |
11-05-2020 |
Time |
10:04 |
Rev Time |
0.00 |
| Received By |
vnoel |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2020-11-05 10:35:52 | 1. DUE TO PROXIMITY TO PROPOSED TREES, WATER MAIN ALONG | | | CLEARWATER WILL ALSO NEED TO BE RELOCATED. | | | 2. SANITARY SEWER LINE RUNNING WEST FROM CLEARWATER | | | WILL BE A PRIVATE LINE TO BE MAINTAINED BY THE MASTER | | | ASSOCIATION. CITY POINT OF SERVICE WILL BE PROPOSED MH | | | #2. | | | 3. THE METER/BACKFLOWS/IRRIGATION ASSEMBLIES IN THE SE | | | CORNER NEEDS TO BE RE-WORKED. IT DOES NOT APPEAR THERE | | | IS ROOM ENOUGH BETWEEN THE EXISTING CONCRETE | | | POLE/ANCHORS AND THE BUILDING TO SERVICE THE METER. | | | 4. AS THE SURVEY INCLUDES THE OVERALL PROPERTY, THE | | | MASTER ASSOC. NEEDS TO BE A CO-APPLICANT. | | | | | | | | | FOLLOWING ARE COMMENTS FROM LAURA LE, PUBLIC UTILITIES | | | ENGINEER | | | | | | 1. NEED TO SHOW EXIST LATERALS AND EXIST WATER | | | SERVICES, IF ANY; THE MOST OF THE LATERALS HAVE | | | RECENTLY BEEN LINED | | | 2. DID THEY TV THE SAN SEWER RECENTLY? DOES PIPE SIZE | | | MATCH SURVEYED INFO? | | | 3. EXIST SAN MH NEED TO BE REHABBED. NOT SURE IF THAT | | | WAS DONE RECENTLY. | | | 4. NEED A PROFILE OF THE NEW SAN SEWER | | | 5. THE SAN SEWER REDUCED BACK TO 8? JUST UPSTREAM OF | | | THE LIFT STATION. WE WILL NEED TO LOOK AT THE PIPE | | | DOWNSTREAM OF THE PROJECT. | | | WE WILL ALSO CHECK THE PUMPS AT THE LIFT STATION | | | 6. IS THERE AN EASEMENT FOR THE EXIST 8? COMING FROM | | | AUSTRALIAN AVE? IS IT CITY?S OWNED AND MAINTAINED? | | | |
|
|
| Review Stop |
SURVEY |
SURVEYING |
| Rev No |
1 |
Status |
F |
Date |
09-08-2020 |
|
|
Cont ID |
|
| Sent By |
vnoel |
Date |
09-08-2020 |
Time |
10:53 |
Rev Time |
|
| Received By |
vnoel |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2020-09-08 11:15:27 | 1. SURVEY NEEDS TO BE SIGNED AND SEALED. | | | 2. LOCATION OF EXISTING UTILITIES NEEDS TO BE FIELD | | | LOCATED, NOT PER CITY GIS. | | | 3. NEED COPY OF ALL DOCUMENTS SHOWN IN TITLE POLICY. | | | NEED APPLICANT TO EXPLAIN HOW THIS CONDOMINIUM | | | ASSOCIATION WILL WORK WITH THE COMMON AREA. | | | 4. STORMWATER WILL NEED TO REVIEW FOR THE OFF-SITE | | | RETENTION. | | | 5. IT APPEARS THAT THERE ARE 2 OWNERS OF THIS OVERALL | | | PROPERTY. WILL NEED CONSENT OF THE ADJOINING EDGE | | | MASTER ASSOC. | | | 6. EXISTING SANITARY ALONG CLEARWATER MAY HAVE RECENTLY | | | BEEN LINED. | | | 7. THERE IS CONCERN OF THE PROPOSED BUILDINGS IN CLOSE | | | PROXIMITY TO THE SANITARY. | | | 8. WHAT DOES THE DRIVEWAY TO THE SOUTHEAST CORNER OF | | | THE EDGE CONNECT TO? IT APPEARS TO BE A CONCRETE | | | WALKWAY? IS THIS A FIRE EXIT? | | | 9. THIS SITE MAY NEED TO BE REPLATTED. |
|
|
| Review Stop |
TRAFFIC |
TRAFFIC ENGINEERING |
| Rev No |
4 |
Status |
F |
Date |
03-31-2021 |
|
|
Cont ID |
|
| Sent By |
|
Date |
03-31-2021 |
Time |
|
Rev Time |
0.00 |
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2021-03-31 15:38:27 | TRAFFIC COMMENTS | | | 1. NOT ACKNOWLEDGED. PER COUNTY RECOMMENDATION: AN | | | INTERSECTION ANALYSIS SHALL BE CONDUCTED AT THE BANYAN | | | AND CLEARWATER INTERSECTION, AS SOON AS EXISTING ROAD | | | CONSTRUCTION IS COMPLETED. DEPENDING ON THE RESULTS AND | | | FINDINGS OF SUCH ANALYSIS, DEVELOPER MAY NEED TO | | | PROVIDE MITIGATION MEASUREMENTS | | | 2. PARTIALLY SATISFIED. AUTOTURN ANALYSIS: VEHICLES' | | | DYNAMIC ENVELOPE MUST BE COLORED SO TO DISTINGUISH FROM | | | ROAD/BUILDING LINES. A BACK-LOADING TRUCK WAS USED AS | | | DESIGN VEHICLE, BUT PATHS SHOWN SEEM TO MODEL A FRONT | | | LOADER ONE. PLEASE PROVIDE AUTOTURN ANALYSIS FOR A | | | SERVICE/MOVING TRUCK ACCESSING THE INTERNAL DOCKS AREA. | | | PLEASE SUBMIT AUTOTURN ANALYSIS RESULTS SEPARATE FROM | | | OTHER DOCUMENTS/PLANS. | | | 3. NOT SATISFIED. TDM: IN ORDER TO PROPERLY IDENTIFY | | | THE RIGHT STRATEGIES, PLEASE DETERMINE THE NUMBER OF | | | DAILY AND PEAK-HOUR VEHICLES REDUCTION REQUIRED TO | | | CLEAR THE 1% SIGNIFICANT IMPACT ON THE ROADWAYS | | | IDENTIFIED IN THE TRAFFIC STUDY. | | | 4. NOT SATISFIED. COORDINATE WITH THE COUNTY TO EXTEND | | | S AUSTRALIAN AVE SOUTHBOUND LEFT-TURN LANE MEDIAN AT | | | THE ONE CLEARLAKE WAY INTERSECTION. SUCH MODIFICATION | | | WILL ALLOW SOUTHBOUND LEFT-TURN VEHICLES ONLY, WHILE | | | PREVENTING WESTBOUND LEFT-TURN MOVEMENTS WITHOUT THE | | | NEED OF A PORK-CHOP ISLAND INSTALLATION. IN CASE OF | | | NEGATIVE RESPONSE FROM THE COUNTY ON SUCH | | | IMPLEMENTATION, PLEASE PROVIDE CORRESPONDING STATEMENT | | | OR CORRESPONDENCE ON THE MATTER. | | | 5. NOT SATISFIED. AUSTRALIAN AVE AND CLEARWATER PL | | | INTERSECTION: RESTRIPE THE WESTBOUND LEG SO TO | | | ACCOMMODATE TWO LEFT-TURN ONLY LANES AND ONE LEFT & | | | RIGHT LANE. COORDINATE WITH THE COUNTY FOR THE | | | ADDITIONAL SIGNAL HEAD NEEDED. IN CASE OF NEGATIVE | | | RESPONSE FROM THE COUNTY ON SUCH IMPLEMENTATION, PLEASE | | | PROVIDE CORRESPONDING STATEMENT OR CORRESPONDENCE ON | | | THE MATTER. | | | | | | VALERIO ORICCHIO | | | CITY TRANSPORTATION ENGINEER | | | 561-494-1092 | | | [email protected] | | | |
|
|
| Review Stop |
TRAFFIC |
TRAFFIC ENGINEERING |
| Rev No |
3 |
Status |
F |
Date |
03-24-2021 |
|
|
Cont ID |
|
| Sent By |
elevesqu |
Date |
03-24-2021 |
Time |
16:19 |
Rev Time |
0.00 |
| Received By |
elevesqu |
Date |
03-24-2021 |
Time |
16:19 |
Sent To |
|
|
| Notes |
| 2021-03-24 16:19:26 | Z20080008 - 350 S AUSTRALIAN ? R3 - 2021-03-21 | | | TRAFFIC COMMENTS | | | 1. PER COUNTY RECOMMENDATION: AN INTERSECTION ANALYSIS | | | SHALL BE CONDUCTED AT THE BANYAN AND CLEARWATER | | | INTERSECTION, AS SOON AS EXISTING ROAD CONSTRUCTION IS | | | COMPLETED. DEPENDING ON THE RESULTS AND FINDINGS OF | | | SUCH ANALYSIS, DEVELOPER MAY NEED TO PROVIDE MITIGATION | | | MEASUREMENTS | | | 2. AUTOTURN ANALYSIS. VEHICLES? DYNAMIC ENVELOPE MUST | | | BE COLORED SO TO DISTINGUISH FROM ROAD/BUILDING LINES. | | | A BACK-LOADING TRUCK WAS USED AS DESIGN VEHICLE, BUT | | | PATHS SHOWN SEEM TO MODEL A FRONT LOADER ONE. PLEASE | | | PROVIDE AUTOTURN ANALYSIS FOR A SERVICE/MOVING TRUCK | | | ACCESSING THE INTERNAL DOCKS AREA. PLEASE SUBMIT | | | AUTOTURN ANALYSIS RESULTS SEPARATE FROM OTHER | | | DOCUMENTS/PLANS. | | | 3. TDM. IN ORDER TO PROPERLY IDENTIFY THE RIGHT | | | STRATEGIES, PLEASE DETERMINE THE NUMBER OF DAILY AND | | | PEAK-HOUR VEHICLES REDUCTION REQUIRED TO CLEAR THE 1% | | | SIGNIFICANT IMPACT ON THE ROADWAYS IDENTIFIED IN THE | | | TRAFFIC STUDY. | | | 4. COORDINATE WITH THE COUNTY TO EXTEND S AUSTRALIAN | | | AVE SOUTHBOUND LEFT-TURN LANE MEDIAN AT THE ONE | | | CLEARLAKE WAY INTERSECTION. SUCH MODIFICATION WILL | | | ALLOW SOUTHBOUND LEFT-TURN VEHICLES ONLY, WHILE | | | PREVENTING WESTBOUND LEFT-TURN MOVEMENTS WITHOUT THE | | | NEED OF A PORK-CHOP ISLAND INSTALLATION. IN CASE OF | | | NEGATIVE RESPONSE FROM THE COUNTY ON SUCH | | | IMPLEMENTATION, PLEASE PROVIDE CORRESPONDING STATEMENT | | | OR CORRESPONDENCE ON THE MATTER. | | | 5. AUSTRALIAN AVE AND CLEARWATER PL INTERSECTION: | | | RESTRIPE THE WESTBOUND LEG SO TO ACCOMMODATE TWO | | | LEFT-TURN ONLY LANES AND ONE LEFT & RIGHT LANE. | | | COORDINATE WITH THE COUNTY FOR THE ADDITIONAL SIGNAL | | | HEAD NEEDED. IN CASE OF NEGATIVE RESPONSE FROM THE | | | COUNTY ON SUCH IMPLEMENTATION, PLEASE PROVIDE | | | CORRESPONDING STATEMENT OR CORRESPONDENCE ON THE | | | MATTER. | | | | | | VALERIO ORICCHIO | | | CITY TRANSPORTATION ENGINEER | | | 561-494-1092 | | | [email protected] | | | |
|
|
| Review Stop |
TRAFFIC |
TRAFFIC ENGINEERING |
| Rev No |
2 |
Status |
F |
Date |
10-28-2020 |
|
|
Cont ID |
|
| Sent By |
|
Date |
11-20-2020 |
Time |
|
Rev Time |
0.00 |
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2020-10-28 17:54:51 | TRAFFIC COMMENTS | | | 1. PROVIDE COUNTY TPS LETTER ONCE OBTAINED | | | 2. PROVIDE A PARAGRAPH IN THE REPORT DISCUSSING | | | SIGNIFICANT IMPACTS OF THE PROPOSED DEVELOPMENT NEWLY | | | GENERATED TRIPS, INCLUSIVE OF A SUMMARY TABLE IN THE | | | REPORT LISTING ONLY THE ROADWAY(S) SIGNIFICANTLY | | | IMPACTED. | | | 3. PROVIDE SYNCHRO/HCM ANALYSIS FOR THE FOLLOWING | | | INTERSECTIONS: | | | A. ACCESS DRIVE AND S AUSTRALIAN AVE (UNSIGNALIZED) | | | B. BANYAN BLVD AND CLEARWATER PLACE (UNSIGNALIZED) | | | ROADWORK MAY PARTIALLY PRECLUDE DATA COLLECTION ON | | | BANYAN, BUT NOT ON AUSTRALIAN. | | | | | | SITE PLAN COMMENTS | | | 4. SHOWCASE DRIVEWAY(S) AND CURB DETAIL FOR PROPERTIES | | | ON THE OPPOSITE SIDE OF THE ROAD ALONG CLEARWATER DR | | | GENERAL COMMENTS | | | 5. PROVIDE TDM STRATEGIES IN ORDER TO MITIGATE THE | | | PROPOSED DEVELOPMENT?S SIGNIFICANT IMPACTS TO THE | | | ROADWAY SYSTEM | | | 6. BASED ON THE RESULTS OF THE INTERSECTION ANALYSIS, | | | CITY MAY REQUIRE INSTALLATION OF A HALF-PORK CHOP | | | ISLAND ON ONE CLEARLAKE WAY IN ORDER TO ENFORCE BY | | | DESIGN RIGHT-TURN-ONLY VEHICLE MOVEMENTS TO AUSTRALIAN | | | AVE. | | | | | | VALERIO ORICCHIO | | | CITY TRANSPORTATION ENGINEER | | | 561-494-1092 | | | [email protected] | | | |
|
|
| Review Stop |
TRAFFIC |
TRAFFIC ENGINEERING |
| Rev No |
1 |
Status |
F |
Date |
09-09-2020 |
|
|
Cont ID |
|
| Sent By |
|
Date |
09-09-2020 |
Time |
|
Rev Time |
|
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2020-09-09 16:35:12 | TRAFFIC COMMENTS | | | | | | 1) PROVIDE COUNTY TPS LETTER | | | 2) FIGURES SHALL BE NUMBERED FOR PROPER REFERENCE | | | 3) TRAFFIC DISTRIBUTION PERCENTAGES DO NOT SEEM | | | COMPLETELY CORRECT | | | 3A) FOR EXAMPLE: 40% OF TRAFFIC HEADS SOUTH ON | | | AUSTRALIAN AVE, BUT THE SPLITS AT OKEECHOBEE BLVD DO | | | NOT SUM CORRECTLY (FIGURE SHOWS: 20%, 5%, 10%) | | | 3B) PLEASE REVIEW AND REVISE INCORRECT DISTRIBUTION | | | PERCENTAGES | | | 4) PROVIDE A FIGURE WITH SATELLITE AERIAL SHOWCASING | | | SITE LOCATION AND RADIUS OF DEVELOPMENT INFLUENCE | | | 5) EXEMPTION FROM CONCURRENCY, DOES NOT IMPLY EXEMPTION | | | FROM HIGHLIGHTING AND REPORTING PROPOSED DEVELOPMENT'S | | | SIGNIFICANT IMPACTS | | | 5A) PROVIDE A PARAGRAPH IN THE REPORT DISCUSSING | | | SIGNIFICANT IMPACTS OF THE PROPOSED DEVELOPMENT' NEWLY | | | GENERATED TRIPS, INCLUSIVE OF A TABLE LISTING THE | | | ROADWAY(S) SIGNIFICANTLY IMPACTED AND RELATED | | | PERFORMANCE MEASURES. | | | 6) PROVIDE SYNCHRO/HCM ANALYSIS FOR THE FOLLOWING | | | INTERSECTIONS: | | | 6A) CLEARWATER PLACE AND S AUSTRALIAN AVE (SIGNALIZED) | | | 6B) ACCESS DRIVE AND S AUSTRALIAN AVE (UNSIGNALIZED) | | | 6C) BANYAN BLVD AND CLEARWATER PLACE (UNSIGNALIZED) | | | | | | SITE PLAN COMMENTS | | | | | | 7) IDENTIFY EXACT DUMPSTER LOCATION FOR GARBAGE TRUCK | | | PICKUP OPERATIONS | | | 8) PROVIDE AUTOTURN ANALYSIS OF GARBAGE AND SERVICE | | | TRUCKS OPERATIONS | | | 9) REDUCE THE NUMBER OF ACCESS POINT/DRIVEWAYS ON | | | CLEARWATER DR TO ONE. | | | 10) SHOWCASE DRIVEWAY(S) AND CURB DETAIL FOR PROPERTIES | | | ON THE OPPOSITE SIDE OF THE ROAD ON CLEARWATER DR | | | 11) CHAOTIC INTERNAL CIRCULATION SCHEME, HAVE ONE LANE | | | IN EACH DIRECTION AT THE MAIN DRIVEWAY THROUGH THE | | | BUILDING | | | 11A) CONSIDER IMPLEMENTING A VALET/DROP-OFF AREA IN | | | LIEU OF BY-PASS LANE(S) | | | | | | | | | VALERIO ORICCHIO | | | CITY TRANSPORTATION ENGINEER | | | 561-494-1092 | | | [email protected] | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
4 |
Status |
P |
Date |
03-31-2021 |
|
|
Cont ID |
|
| Sent By |
elevesqu |
Date |
03-31-2021 |
Time |
13:57 |
Rev Time |
0.00 |
| Received By |
elevesqu |
Date |
03-31-2021 |
Time |
13:56 |
Sent To |
|
|
| Notes |
| 2021-03-31 14:02:51 | PROVISOS: | | | | | | A. THE FOLLOWING ITEMS SHALL BE ADDRESSED DURING THE | | | BUILDING PERMIT PROCESS: | | | | | | 1. THE DESIGN OF THE PUBLIC OPEN SPACE SHALL BE | | | SUBMITTED THROUGH AN AMENDMENT AND SUBJECT TO DAC | | | REVIEW. THE PUBLIC OPEN SPACE SHALL EXPLORE THE | | | INCORPORATION OF THE AIPP REQUIREMENT. THE AMENDMENT | | | SHALL INCLUDE RENDERINGS WHICH SHOW INTERACTION OF | | | PUBLIC OPEN SPACE WITH BUILDING. | | | | | | 2. GROUND FLOOR WINDOWS SHALL MAINTAIN TRANSPARENCY | | | BETWEEN GROUND FLOOR COMMERCIAL SPACES AND EXTERIOR. | | | | | | 3. PLEASE SUBMIT REVISED SECTION A-A TO ACCURATELY | | | REFLECT PROPOSED LANDSCAPE AND WALL SEATING. | | | | | | 4. ALL ROOFTOP EQUIPMENT SHALL BE SCREENED TO THE | | | HEIGHT OF THE EQUIPMENT. ALL WALL MOUNTED EQUIPMENT | | | SHALL BE ARCHITECTURALLY SCREENED OR PAINTED TO MATCH | | | BUILDING FA?ADE | | | | | | 5. ALL GRADE CHANGES SHOULD OCCUR INTERIOR TO THE | | | BUILDING, NOT ON THE SIDEWALK/ROW | | | | | | 6. EXACT AMOUNT OF CAR SHARE SPACES OR NEED FOR ANY TO | | | BE DETERMINED THROUGHOUT BUILDING PERMIT PROCESS | | | | | | 7. ALL FDC SHALL BE WALL MOUNTED BEHIND LANDSCAPE BEDS | | | IF AUTHORIZED BY THE CITY. | | | | | | 8. THE PARKING GARAGE ENTRANCE SHALL BE TREATED, | | | INCLUDING THE CEILING FOR THE FIRST 20 FEET. ALL | | | PORTIONS OF THE PARKING GARAGE THAT CAN BE SEEN FROM | | | THE PUBLIC SIDEWALK OR STREET SHALL BE TREATED | | | INCLUDING THE CEILING, AT MINIMUM TO THE FIRST 20 FEET. | | | ALL GARAGE LIGHTING SHALL BE SHIELDED FROM THE PUBLIC | | | SIDEWALK AND STREETS. | | | | | | 9. THE INCLUSION OF A GATE TO THE SOUTH OF THE EDGE | | | PARKING GARAGE SHALL BE EXAMINED TO SCREEN THE DUMPSTER | | | STAGING AREA. | | | | | | 10. PROVIDE ARCHITECTURAL SCREENING GATE NOT JUST GATE | | | ARM TO SCREEN LOADING AREA FROM ROW. | | | | | | 11. ALL STREET LIGHTS, TREE GRATES, BOLLARDS, PAVERS OR | | | ANY OTHER STREETSCAPE ELEMENTS INSTALLED WITHIN THE | | | CITY?S ROW SHALL COMPLY WITH CITY?S STANDARDS, AND | | | SHALL BE APPROVED BY THE PLANNING DIVISION AND THE | | | ENGINEERING SERVICES DEPARTMENT DURING THE BUILDING | | | PERMIT PROCESS. ANY FEES ASSOCIATED WITH THE REMOVAL OF | | | EXISTING STREET LIGHTS SHALL BE A COST TO THE OWNER. | | | | | | 12. THE PROJECT IS REQUIRED TO COMPLY WITH THE ART IN | | | PUBLIC PLACES ORDINANCE. | | | 13. PRIOR TO THE ISSUANCE OF THE FIRST BUILDING PERMIT, | | | THE APPLICANT SHALL PREPARE A CONSTRUCTION SITE | | | SECURITY AND MANAGEMENT PLAN FOR APPROVAL BY THE CITY | | | OF WEST PALM BEACH POLICE DEPARTMENT CPTED OFFICIAL. | | | | | | 14. THE APPLICANT, SUCCESSORS AND ASSIGNS SHALL BE | | | RESPONSIBLE FOR THE PERMITTING AND INSTALLATION OF THE | | | STREET TREES AND RIGHT OF WAY LANDSCAPING AND | | | IRRIGATION APPROVED WITH THIS PETITION. | | | | | | 15. PRIOR TO THE REMOVAL OR RELOCATION OF ANY TREES ON | | | THE PROPERTY, A TREE ALTERATION PERMIT SHALL BE | | | SUBMITTED, REVIEWED AND APPROVED BY THE DEVELOPMENT | | | SERVICES DEPARTMENT, PLANNING DIVISION. | | | | | | 16. IRRIGATION FOR STREET TREES AND LANDSCAPING IN THE | | | RIGHT OF WAYS SHALL BE PROVIDED BY THE APPLICANT, | | | SUCCESSORS AND ASSIGNS FROM THE SUBJECT DEVELOPMENT. | | | ALL EXISTING CITY IRRIGATION LINES RUNNING TO | | | INDIVIDUAL AREAS OR TREES SHALL BE REMOVED AND CAPPED | | | IN SUCH A WAY TO ENSURE CITY IRRIGATION SUPPLY LINES | | | SHALL REMAIN INTACT AND CONTINUOUS FOR OTHER AREAS | | | SERVED BY THE LINES | | | | | | 17. A PHOTOMETRIC PLAN THAT SHOWS LOCATION OF LIGHT | | | POLES, AND ILLUSTRATES LOCATION OF TREES SHALL BE | | | SUBMITTED AT TIME OF BUILDING PERMIT REVIEW. | | | PHOTOMETRICS SHALL INCLUDE PUBLIC OPEN SPACE, ALL | | | SIDEWALKS AND PATHS AND PARKING AREAS. | | | | | | 18. SITE LOCATIONS OF GROUND MOUNTED UTILITIES SHALL | | | INCLUDE REVIEW BY ZONING. | | | | | | 19. ALL GROUND MOUNTED UTILITIES SHALL BE SCREENED BY | | | LANDSCAPING TO THE LARGEST EXTENT POSSIBLE. | | | | | | 20. AN ENCROACHMENT EASEMENT MAY BE REQUIRED FOR THE | | | ENCROACHMENT OF BALCONIES INTO THE EDGE MASTER | | | ASSOCIATION PROPERTY. | | | | | | 21. THE PROJECT SHALL CONTRIBUTE TO THE TROLLEY FEE DUE | | | TO THE INCLUSION OF MICROUNITS, AT A RATE ESTABLISHED | | | BY RESOLUTION. | | | | | | 22. THE NECESSARY ELECTRICAL CONNECTIONS WILL BE | | | PROVIDED FOR THE MICROMOBILITY STATION PER CITY TRAFFIC | | | ENGINEERING REQUIREMENTS. | | | | | | 23. THE GATE AT EGRESS DRIVE SHALL BE OF ARCHITECTURAL | | | MATERIAL, NOT JUST A GATE ARM, TO HIDE THE LOADING AREA | | | FROM THE ROW. | | | | | | 24. THE TRASH COLLECTION PLAN WILL BE WORKED OUT | | | BETWEEN THE OWNER AND EDGE CONDO TO DETERMINE HOW MANY | | | TRASH PICKUP DAYS ARE REQUIRED. | | | | | | 25. THE SIDEWALK ELEVATION SHALL BE MAINTAINED ACROSS | | | ANY DRIVEWAY. | | | | | | 26. EXTEND THE MEDIAN ON AUSTRALIAN TO PREVENT LEFT | | | TURN OUT FROM CLEARWATER ACCESS DRIVE. IF THE EXTENSION | | | IS NOT APPROVED BY THE COUNTY, THIS CONDITION WILL NOT | | | APPLY. | | | | | | B. THE FOLLOWING ITEMS SHALL BE ADDRESSED PRIOR TO | | | ISSUANCE OF FINAL CO: | | | 27. PAVEMENT SHALL BE RESURFACED IN ACCORDANCE WITH | | | CITY STANDARDS TO ANY AREA WHERE PAVEMENT MARKINGS ARE | | | REMOVED. | | | | | | 28. THE APPLICANT, SUCCESSORS AND ASSIGNS SHALL BE | | | RESPONSIBLE FOR THE MAINTENANCE OF THE ROAD RIGHT OF | | | WAY LANDSCAPING AND IRRIGATION ADJACENT TO THE | | | DEVELOPMENT. THIS WILL BE THROUGH A SEPARATE | | | MAINTENANCE AGREEMENT WITH THE CITY. | | | | | | | | | LIZ LEVESQUE, URBAN DESIGN PLANNER | | | | | | PLEASE CONTACT ANA MARIA APONTE, CITY URBAN DESIGNER | | | WITH ANY QUESTIONS. [email protected] OR 561 822 1439 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
F |
Date |
03-22-2021 |
|
|
Cont ID |
|
| Sent By |
elevesqu |
Date |
03-22-2021 |
Time |
10:34 |
Rev Time |
0.00 |
| Received By |
elevesqu |
Date |
03-31-2021 |
Time |
13:56 |
Sent To |
|
|
| Notes |
| 2021-03-22 10:34:50 | | | | | | | GENERAL COMMENTS: | | | 1. SATISFIED | | | 2. SATISFIED. ADDITIONAL INFORMATION IS NECESSARY TO | | | MAKE FINAL DETERMINATION OF SITE CALCULATIONS. | | | A. SATISFIED. WHAT ARE THE LEGAL PARAMETERS THAT | | | REGULATE THE MASTER ASSOCIATION? | | | B. SATISFIED. IS DRAINAGE FOR PHASE II ALLOWED WITHIN | | | THE MASTER ASSOCIATION AREA? CAN IT BE LOCATION OUTSIDE | | | PHASE II PARCEL? | | | C. SATISFIED. IS EDGE ASSOCIATION CONSENTING FOR OPEN | | | SPACE TO BE OPEN TO THE PUBLIC? ARE THEY AWARE OPEN | | | SPACE PERMITS THE PUBLIC TO ENTER? | | | D. CONDITION OF APPROVAL: EXTENSION OF BALCONIES INTO | | | EDGE ASSOCIATION PROPERTY ? NEED TO CONFIRM IF | | | PERMITTED ? EASEMENT SHALL BE REQUIRED | | | E. SATISFIED. MEASUREMENT OF SIDE INTERIOR SETBACK AND | | | REAR SETBACK DETERMINED BASED ON HOW PROPERTY LINES | | | WILL BE MODIFIED WITH PROJECT | | | F. SATISFIED. HOW WILL INTERNAL DRIVE BE MAINTAINED AND | | | OPERATED? | | | 3. SATISFIED | | | 4. ONGOING. CAN EXISTING DRAINAGE BE DISENGAGED? | | | STORMWATER DRAINAGE UNDER REVIEW BY CITY ENGINEERING | | | DEPARTMENT. | | | 5. SATISFIED | | | 6. SATISFIED. | | | 7. SATISFIED. | | | 8. SATISIFED. | | | 9. SATISFIED | | | 10. SATISFIED | | | 11. SATISFIED | | | 12. SATISFIED | | | 13. SATISFIED | | | 14. SATISFIED. | | | 15. SATISFIED | | | 16. SATISFIED | | | 17. SATISFIED | | | 18. SATISFIED | | | 19. SATISFIED | | | 20. SATISFIED | | | 21. SATISFIED | | | 22. SATISFIED | | | 23. SATISFIED | | | 24. SATISFIED | | | 25. ONGOING ? PARTIALLY SATISFIED. HOW WILL TRASH | | | PICKUP WORK FOR NEW BUILDING? WHERE WILL EXISTING TRASH | | | FOR EDGE BUILDING BE RELOCATED? | | | NEED CONFIRMATION FROM MATT HEJAZI. MAY WANT TO HAVE | | | FULL DUMPSTER ENCLOSURE. ONGOING DISCUSSION WITH PUBLIC | | | WORKS | | | 26. SATISFIED. | | | 27. SATISFIED | | | 28. SATISFIED | | | 29. SATISFIED | | | 30. SATISFIED | | | 31. SATISFIED. | | | 32. SATISFIED | | | 33. SATISFIED. | | | 34. SATISFIED | | | 35. SATISFIED | | | 36. SATISFIED. | | | 37. SATISFIED | | | 38. CONDITION OF APPROVAL. PROVIDE PHOTOMETRIC ANALYSIS | | | PLANS ? TO INCLUDE PUBLIC OPEN SPACE, ALL BUILDING | | | ENTRANCES AND PATHWAYS ? INCLUDING DOG PARK ENTRANCE | | | COORDINATED DURING BUILDING PERMIT PROCESS | | | LANDSCAPE: | | | 39. SATISFIED | | | 40. SATISFIED. | | | 41. SATISFIED | | | 42. CONDITION OF APPROVAL. SPECIFIC TYPE OF PUBLIC OPEN | | | SPACE AND PRIVATE OPEN SPACE IS REQUIRED. PLEASE | | | INCLUDE SPECIFIC TYPE AND TABLES ILLUSTRATING HOW | | | REQUIREMENTS FOR SPECIFIC OPEN SPACE TYPES HAVE BEEN | | | MET. NEED ADDITIONAL DETAIL TO DETERMINE IF OPEN SPACE | | | IS AN IMPROVEMENT ON SITE. THE INITIAL DESIGN DOES NOT | | | SEEM TO BE A BIG IMPROVEMENT TO PUBLIC SPACE. NEED TO | | | COORDINATE | | | DESIGN OF PUBLIC OPEN SPACE TO BE FURTHER REVIEWED, AND | | | BROUGHT BACK TO DOWNTOWN ACTION COMMITTEE AT FUTURE | | | DATE WITH INCORPORATION OF AIPP REQUIREMENT | | | 43. SATISFIED. | | | 44. CONDITION OF APPROVAL. PROVIDE HARDSCAPE PLAN | | | ILLUSTRATING PROPOSED CONCEPTUAL PAVERS, FOUNTAIN | | | (INCLUDING DEPTH OF FOUNTAIN AND PROTECTIVE BARRIER), | | | PAVER BANDING/CONCRETE BANDING, SEATING OPEN SPACE, | | | ETC. | | | DESIGN OF PUBLIC OPEN SPACE TO BE FURTHER REVIEWED, AND | | | BROUGHT BACK TO DOWNTOWN ACTION COMMITTEE AT FUTURE | | | DATE WITH INCORPORATION OF AIPP REQUIREMENT | | | 45. NOT SATISFIED. LANDSCAPE PLAN SHEET PL-1 DOES NOT | | | SEEM TO ACCOUNT FOR FIRE, IRRIGATION AND WATER ASSEMBLY | | | ADJACENT TO PROPOSED OPEN SPACE ? PLEASE COORDINATE | | | WITH CIVIL PLAN | | | REPEAT COMMENT ? NOT SHOWN ON LANDSCAPE PLANS: LOW | | | SHRUBS CAN BE PLANTED IN FRONT OF FIRE BACKFLOW, | | | IRRIGATION METER. FROM PAST CASES, THEY CANNOT BE | | | PLANTED IN FRONT OF DOMESTIC BACKFLOW BUT PLEASE | | | CONFIRM WITH PUBLIC UTILITIES. THE SIDEWALK BETWEEN | | | THESE UTILITIES AND THE BACK OF CURB IS APPROXIMATELY | | | 12 FEET ? CAN BE REDUCED TO 8 FEET TO ACCOMMODATE | | | ADDITIONAL LANDSCAPE IN FRONT OF UTILITIES. PLEASE | | | EXAMINE POSSIBILITY AND SEE HOW IT INTERACTS WITH THE | | | REST OF THE PROPOSED PUBLIC OPEN SPACE AND SIDEWALK | | | ALONG CLEARWATER | | | 46. SATISFIED | | | 47. PARTIALLY SATISFIED. ARE TREES PROPOSED ALONG | | | CLEARWATER DRIVE IN A LANDSCAPE BED? THIS IS PREFERRED | | | IF 8-FOOT SIDEWALK CLEARANCE CAN BE MAINTAINED BETWEEN | | | BUILDING FA?ADE AND BED (APPEARS IT CAN) | | | TREES SHALL BE PLANTED ALONG CURB LINE IN PLANTER BED | | | RATHER THAN FA?ADE PLANTING. CONTINUOUS PLANTER BED CAN | | | BE LOCATED ALONG ENTIRE FA?ADE WHERE THERE IS NO | | | CROSSWALK OR CURB CUT | | | 48. SATISFIED | | | 49. SATISFIED. | | | 50. NOT SATISFIED. ABOVE GROUND UTILITIES ALONG | | | BUILDINGS SOUTH FA?ADE SHALL BE SCREENED WITH LANDSCAPE | | | HEDGE TO BEST EXTENT POSSIBLE. PLEASE INCLUDE IN | | | LANDSCAPE PLAN | | | COORDINATE LANDSCAPE SCREENING AROUND THESE UTILITIES | | | WHEN THEY ARE IN THEIR FINAL APPROVED LOCATION. FOR THE | | | SAKE OF SITE PLAN REVIEW, PLEASE PLACE LOW LANDSCAPE ON | | | ALL SIDES OF THE FDC, FIRE BACKFLOW, IRRIGATION METER, | | | AND ON THREE SIDES OF THE WATER METER AND DOMESTIC | | | BACKFLOW (CANNOT BE PLANTED ON THE ACCESSED SIDE OF | | | WATER METER AND DOMESTIC BACKFLOW). IN THE CASE THAT | | | PUBLIC UTILITIES REQUIRES ANY OF THESE UTILITIES TO BE | | | LOCATED ON THE ROW (NOT WITHIN PRIVATE PROPERTY), | | | PLEASE PLACE UP AGAINST BUILDING WITH FA?ADE PLANTING, | | | OR ALONG CURB LINE SURROUNDING BY PLANTING. CONTINUE | | | COORDINATION WITH ZONING DEPARTMENT | | | 51. SATISFIED | | | 52. SATISFIED. | | | 53. CONDITION OF APPROVAL. DUE TO THE SITE?S SIZE AND | | | THE REQUEST FOR VARIANCES, THIS PROJECT IS SUBJECT TO | | | DAC REVIEW PRIOR TO COMPLETING PPRC PROCESS | | | PUBLIC OPEN SPACE SUBJECT TO FURTHER DAC REVIEW WITH | | | INCORPORATION OF AIPP | | | 54. CONDITION OF APPROVAL. APPLICANT SHALL MEET AIPP | | | REQUIREMENTS ? CONTACT SYBILLE WELTER, AIPP COORDINATOR | | | AT [email protected] | | | CIVIL: | | | 55. SATISFIED | | | 56. SATISFIED. | | | 57. CONDITION OF APPROVAL. PLEASE NOTE, LOCATION OF ALL | | | ABOVE GROUND UTILITIES, INCLUDING BACKFLOW ASSEMBLIES, | | | WATER METERS, FDC, FIRE BACKFLOWS, GENERATORS, | | | IRRIGATION METERS, ETC. REQUIRE ZONING APPROVAL IN | | | COORDINATION WITH PUBLIC WORKS AND CITY ENGINEERING | | | DEPARTMENT | | | COORDINATION BETWEEN UTILITIES, FIRE, AND ZONING SHALL | | | CONTINUE THROUGHOUT CONSTRUCTION PROCESS. ZONING SHALL | | | BE INCLUDED IN FINAL LOCATION PLACEMENT | | | 58. SATISFIED | | | 59. SATISFIED | | | 60. SATISFIED | | | 61. SATISFIED | | | 62. SATISFIED | | | 63. NOT SATISFIED. PROVIDE CROSS SECTIONS FOR | | | SIDEWALKS, PARALLEL PARKING SPACES, OPEN SPACE AREAS, | | | ETC. PLEASE PROVIDE A PARALLEL CUB CUT ACROSS ALL | | | PARKING GARAGE ENTRANCES, SHOWING SLOPE OF SIDEWALK | | | PROVIDE CROSS SECTION PARALLEL TO CLEARWATER DRIVE, | | | ACROSS PARKING GARAGE ENTRANCE THAT SHOWS THE SLOPE OF | | | THE SIDEWALK FROM NORTH TO SOUTH AS IT CROSSES THE | | | ENTRANCE. SIDEWALK SHALL BE KEPT LEVEL ACROSS ENTRANCE | | | 64. CONDITION OF APPROVAL. SHOW ALL DOORWAYS ON CIVIL | | | PLANS AND INDICATE HOW GRADE CHANGES ARE BEING | | | ACCOMMODATED. ALL GRADE CHANGES SHOULD OCCUR INTERIOR | | | TO THE BUILDING, NOT ON THE SIDEWALK/ROW | | | NEW COMMENTS OCTOBER 30, 2020: | | | 65. SATISFIED | | | ARCHITECTURE: | | | 66. NOT SATISFIED. IS A GATE PROPOSED AT THE SOUTH | | | EGRESS ONLY DRIVE ONTO CLEARWATER? PLEASE INDICATE ON | | | SITE PLAN AND ON ARCHITECTURAL PLANS. PLEASE INCLUDE | | | MATERIAL DETAIL | | | PLEASE PROVIDE ARCHITECTURAL SCREENING GATE NOT JUST | | | GATE ARM TO SCREEN LOADING AREA FROM ROW | | | 67. SATISFIED | | | 68. CONDITION OF APPROVAL. PLEASE INCLUDE RENDERINGS | | | SHOWING INTERACTION OF PUBLIC OPEN SPACE WITH PROPOSED | | | BUILDING, AND VIEW FROM NORTHWEST LOOKING SOUTHEAST, | | | AND VIEW FROM SOUTH EAST CORNER LOOKING NORTH WEST. | | | 69. CONDITION OF APPROVAL: PLEASE NOTE, WINDOW MATERIAL | | | TINTING SHALL MAINTAIN TRANSPARENCY BETWEEN GROUND | | | FLOOR COMMERCIAL SPACES AND EXTERIOR. PLEASE PROVIDE | | | MATERIAL SPEC (UNDERSTANDING THIS MAY CHANGE DURING | | | PERMIT PROCESS, BUT TRANSPARENCY MUST BE MAINTAINED) | | | 70. SATISFIED | | | 71. SATISFIED | | | 72. SATISFIED | | | 73. SATISFIED | | | 74. CONDITION OF APPROVAL: PLEASE INCLUDE AN OPAQUE | | | GATE SOMEWHERE APPROPRIATE WITHIN THE SPACE BETWEEN THE | | | EDGE AND PROPOSED 350 PROJECT TO SCREEN THE BACK OF | | | HOUSE/DUMPSTER STAGING AREA FROM THOSE WITHIN THE | | | CIRCULAR DRIVE AND THE PUBLIC VIEW FROM THE ACCESS | | | EASEMENT ROADWAY | | | 75. SATISFIED. | | | TRAFFIC: | | | 76. SATISIFED | | | 77. SATISFIED. | | | LANDSCAPE: | | | 78. SATISFIED | | | 79. SATISFIED | | | 80. CONDITON OF APPROVAL: OVERALL, STAFF FEELS THAT THE | | | PUBLIC OPEN SPACE NEEDS TO BE ENHANCED AND BETTER | | | DESIGNED TO INTERACT WITH THE EXISTING AND PROPOSED | | | BUILDING. A DIFFERENT TYPE OF OPEN SPACE WILL NEED TO | | | BE PICKED AND THE CRITERIA MET. STAFF RECOMMENDS A | | | CONFERENCE CALL WITH THE LANDSCAPE PLANNER AND URBAN | | | DESIGN TO DISCUSS FURTHER | | | PUBLIC OPEN SPACE TO BE FURTHER REVIEWED BY DAC WITH | | | INCORPORATION OF AIPP REQUIREMENT | | | CIVIL/SITE: | | | 81. SATISFIED | | | 82. SATISFIED | | | 83. SATISFIED | | | 84. ONGOING. ADD LABEL TO PROPOSED STAGING AREA FOR | | | TRASH ? CURRENTLY READS AS ONLY STAGING FOR THE EDGE | | | TRASH. PLEASE CLARIFY THAT THIS IS ALSO PROPOSED | | | STAGING FOR PROPOSED 350 BUILDING. PLEASE ILLUSTRATE | | | NUMBER OF COMPACTORS AND RECYCLING BINS THAT CAN FIT | | | WITHIN THIS STAGING AREA SAFELY ? USE ACTUAL DIMENSIONS | | | OF EDGE COMPACTORS AND PROPOSED 350 COMPACTORS. THIS | | | WILL NEED TO BE REVIEWED BY PUBLIC WORKS (MATT HEJAZI) | | | WAITING FOR REVIEW BY PUBLIC WORKS | | | 85. PARTIALLY SATISFIED. CIVIL PLANS APPEAR TO SHOW | | | WALL AROUND DUMPSTER STAGING AREA BUT DOES NOT APPEAR | | | ON OTHER PLANS. PLEASE CLARIFY | | | MIGHT WANT A FULL ENCLOSURE NOT JUST CURB ? CHECK WITH | | | MATT HEJAZI | | | 86. SATISFIED | | | 87. SATISFIED | | | 88. SATISFIED | | | 89. SATISFIED | | | 90. COA: PLEASE AMEND THE CROSS SECTION A-A TO | | | ACCURATELY REFLECT PROPOSED LANDSCAPE AND WALL SEATING | | | TO BE REVISED FOR BUILDING PERMIT AFTER PUBLIC OPEN | | | SPACE IS APPROVED | | | 91. SATISFIED | | | 92. SATISFIED | | | 93. SATISFIED | | | 94. SATISIFIED | | | | | | PROPOSED CONDITIONS OF APPROVAL: | | | 1. ALL PORTIONS OF THE PARKING GARAGE SHALL BE PAINTED | | | (CEILING AND WALLS INCLUDING ANY UTILITIES AND PIPING) | | | TO A DEPTH OF 20 FEET. ALL PARKING GARAGE LIGHTING | | | SHALL BE SHIELDED | | | 2. PLEASE NOTE, ALL PROJECTS WITH MICROUNITS SHALL | | | CONTRIBUTE TO THE CITY TROLLEY FUND AT A RATE OF $10 | | | PER MICROUNIT PER MONTH | | | 3. ALL ROOFTOP EQUIPMENT SHALL BE SCREENED TO THE | | | HEIGHT OF THE EQUIPMENT. ALL WALL MOUNTED EQUIPMENT | | | SHALL BE ARCHITECTURALLY SCREENED OR PAINTED TO MATCH | | | BUILDING FA?ADE | | | 4. ALL GRADE CHANGES SHOULD OCCUR INTERIOR TO THE | | | BUILDING, NOT ON THE SIDEWALK/ROW | | | 5. EXACT AMOUNT OF CAR SHARE SPACES OR NEED FOR ANY TO | | | BE DETERMINED THROUGHOUT BUILDING PERMIT PROCESS | | | 6. EASEMENT REQUIRED FOR EXTENSION OF BALCONIES INTO | | | EDGE MASTER ASSOCIATION PROPERTY | | | 7. DETAILS OF PROPOSED DOG PARK TO BE COORDINATED | | | DURING BUILDING PERMIT PROCESS. STAFF RECOMMENDS | | | ANALYZING PROPOSED ENTRANCE TO DOG PARK. LOOKS LIKE THE | | | ONLY WAY TO GET THERE IS THROUGH THE CORRIDOR THAT GOES | | | IN FRONT OF THE GENERATOR ROOMS OR HAVING TO WALK | | | THROUGH THE ASPHALT DUMPSTER STAGING AREA. NOT A ZONING | | | REQUIREMENT BUT A RECOMMENDATION FOR THE TENANT?S | | | ENJOYMENT | | | 8. PROVIDE PHOTOMETRIC ANALYSIS PLANS ? TO INCLUDE | | | PUBLIC OPEN SPACE, ALL BUILDING ENTRANCES AND PATHWAYS | | | ? INCLUDING DOG PARK ENTRANCE | | | 9. DESIGN OF PUBLIC OPEN SPACE TO BE FURTHER REVIEWED, | | | AND BROUGHT BACK TO DOWNTOWN ACTION COMMITTEE AT FUTURE | | | DATE WITH INCORPORATION OF AIPP REQUIREMENT | | | A. PLEASE INCLUDE RENDERINGS SHOWING INTERACTION OF | | | PUBLIC OPEN SPACE WITH PROPOSED BUILDING, AND VIEW FROM | | | NORTHWEST LOOKING SOUTHEAST, AND VIEW FROM SOUTH EAST | | | CORNER LOOKING NORTH WEST. | | | B. PLEASE AMEND THE CROSS SECTION A-A TO ACCURATELY | | | REFLECT PROPOSED LANDSCAPE AND WALL SEATING | | | 10. PLEASE NOTE, WINDOW MATERIAL TINTING SHALL MAINTAIN | | | TRANSPARENCY BETWEEN GROUND FLOOR COMMERCIAL SPACES AND | | | EXTERIOR. PLEASE PROVIDE MATERIAL SPEC WITH BUILDING | | | PERMIT | | | 11. PLEASE INCLUDE AN OPAQUE GATE SOMEWHERE APPROPRIATE | | | WITHIN THE SPACE BETWEEN THE EDGE AND PROPOSED 350 | | | PROJECT TO SCREEN THE BACK OF HOUSE/DUMPSTER STAGING | | | AREA FROM THOSE WITHIN THE CIRCULAR DRIVE AND THE | | | PUBLIC VIEW FROM THE ACCESS EASEMENT ROADWAY | | | SEE OTHER DEPARTMENT COMMENTS FOR ADDITIONAL STANDARD | | | PROPOSED PROVISOS | | | | | | LIZ LEVESQUE, URBAN DESIGN PLANNER | | | 561 822 1426 | | | [email protected] | | | | | | ANA MARIA APONTE, CITY URBAN DESIGNER | | | 561 822 1439 | | | [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
10-30-2020 |
|
|
Cont ID |
|
| Sent By |
elevesqu |
Date |
10-30-2020 |
Time |
12:32 |
Rev Time |
0.00 |
| Received By |
elevesqu |
Date |
10-30-2020 |
Time |
12:31 |
Sent To |
|
|
| Notes |
| 2020-10-30 12:32:24 | | | | | | | GENERAL COMMENTS: | | | 1. SATISFIED | | | 2. ONGOING DISCUSSION WITH APPLICANT LEGAL TEAM AND | | | CITY. ADDITIONAL INFORMATION IS NECESSARY TO MAKE FINAL | | | DETERMINATION OF SITE CALCULATIONS. | | | A. WHAT ARE THE LEGAL PARAMETERS THAT REGULATE THE | | | MASTER ASSOCIATION? | | | B. IS DRAINAGE FOR PHASE II ALLOWED WITHIN THE MASTER | | | ASSOCIATION AREA? CAN IT BE LOCATION OUTSIDE PHASE II | | | PARCEL? | | | C. IS EDGE ASSOCIATION CONSENTING FOR OPEN SPACE TO BE | | | OPEN TO THE PUBLIC? ARE THEY AWARE OPEN SPACE PERMITS | | | THE PUBLIC TO ENTER? | | | D. EXTENSION OF BALCONIES INTO EDGE ASSOCIATION | | | PROPERTY ? NEED TO CONFIRM IF PERMITTED | | | E. MEASUREMENT OF SIDE INTERIOR SETBACK AND REAR | | | SETBACK DETERMINED BASED ON HOW PROPERTY LINES WILL BE | | | MODIFIED WITH PROJECT | | | F. HOW WILL INTERNAL DRIVE BE MAINTAINED AND OPERATED? | | | 3. PARTIALLY SATISFIED | | | REMOVE ACTIVE USE, TRANSPARENCY DATA FOR THE EDGE. ONLY | | | DATA FOR THE ENTIRE SITE TO REMAIN IS THE PUBLIC OPEN | | | SPACE. PLEASE UPDATE FAR DATA LABEL FOR SUBJECT PARCEL | | | TO ?350? (CURRENTLY READS ?305?) | | | 4. ONGOING. CAN EXISTING DRAINAGE BE DISENGAGED? | | | STORMWATER DRAINAGE UNDER REVIEW BY CITY ENGINEERING | | | DEPARTMENT. | | | 5. SATISFIED | | | 6. PARTIALLY SATISFIED. SHEET A ? 0.01 | | | A. SATISFIED. LABEL STREET NAMES ASSOCIATED WITH THEIR | | | DESIGNATIONS UNDER MIN. ACTIVE USE TABLE | | | B. SATISFIED. INCLUDE ACTUAL PROVIDED SETBACK FOR SIDE | | | INTERIOR SOUTH | | | C. SEE NEW COMMENT #70 INCLUDE VARIANCE TABLE FOR | | | PROPOSED VARIANCES. PLEASE NOTE, SETBACK FOR GROUND | | | FLOOR, PODIUM AND TOWER ARE THREE SEPARATE VARIANCE | | | REQUESTS | | | D. SATISFIED. MINIMUM GUEST PARKING FOR MICROUNITS IS | | | 1/20 NOT 0, PLEASE UPDATE IN TABLE | | | 7. SATISFIED. | | | 8. SATISIFED. THE TOTAL AMOUNT OF CAR-SHARE STATIONS | | | MAY BE REDUCED BY ONE CAR-SHARE STATION PER EVERY 13 | | | ON-SITE PARKING SPACES PROVIDED. CAR SHARE STATIONS CAN | | | BE REDUCED BY NUMBER OF PARKING SPACES PROVIDED FOR THE | | | MICROUNITS. DEDUCTION BASED ON CURRENT NUMBERS WOULD BE | | | 9 SPACES, RESULTING IN A NEED FOR 9 CAR SHARE SPACES. | | | EXACT AMOUNT OF CAR SHARE SPACES OR NEED FOR ANY TO BE | | | DETERMINED THROUGHOUT BUILDING PERMIT PROCESS | | | 9. SATISFIED | | | 10. SATISFIED | | | 11. SATISFIED | | | 12. SATISFIED | | | 13. SATISFIED | | | 14. PARTIALLY SATISFIED. REDUCE NUMBER OF DRIVEWAY AND | | | CURB CUTS FROM PROJECT. ELIMINATE FROM CLEARWATER DRIVE | | | IF POSSIBLE. NO MORE THAN ONE ON CLEARWATER IF ALL | | | CANNOT BE ELIMINATED. REDUCE INTERNAL TO TWO LANES ONLY | | | CAN THE APRON WIDTH BE REDUCED? PLEASE CHECK ? SEEM | | | WIDER THAN NECESSARY | | | 15. SATISFIED | | | 16. SATISFIED | | | 17. SATISFIED | | | 18. SATISFIED | | | 19. SATISFIED | | | 20. SATISFIED | | | 21. SATISFIED | | | 22. SATISFIED | | | 23. SATISFIED | | | 24. PARTIALLY SATISFIED: SHOW ADJACENT PROPERTY CURB | | | LINES, PARKING LOTS, STRUCTURES ETC. ON SITE PLAN AND | | | CIVIL PLANS | | | NOT SHOWN ON CIVIL PLANS | | | 25. PARTIALLY SATISFIED. HOW WILL TRASH PICKUP WORK FOR | | | NEW BUILDING? WHERE WILL EXISTING TRASH FOR EDGE | | | BUILDING BE RELOCATED? | | | NEED TO HAVE DISCUSSION WITH EDGE BUILDING FOR THEIR | | | CURRENT STORAGE TO CONFIRM. NEED CONVERSATION WITH MATT | | | HEJAZI OF PUBLIC WORKS TO CONFIRM TRUCK ENTRY ON PAVED | | | CIRCULAR DRIVE | | | 26. SATISFIED. | | | 27. SATISFIED | | | 28. SATISFIED | | | 29. SATISFIED | | | 30. SATISFIED | | | 31. NOT SATISFIED. PLEASE SUBMIT COLOR RENDERINGS FROM | | | GROUND VIEW PERSPECTIVE. INCLUDE LANDSCAPE AS PROPOSED, | | | AT PLANTING HEIGHT FOR ACCURATE CONSTRUCTION | | | REPRESENTATION. | | | 32. SATISFIED | | | 33. PARTIALLY SATISFIED. PLEASE SUBMIT CONTEXTUAL | | | ELEVATIONS | | | NEED MORE DETAILED CONTEXTUAL ELEVATIONS AND RENDERINGS | | | 34. SATISFIED | | | 35. SATISFIED | | | 36. PARTIALLY SATISFIED. WHERE IS THE ACCESS TO THE DOG | | | PARK PROPOSED? WILL IT CONNECT TO CLEARWATER DRIVE? | | | PLEASE PROVIDE MORE DETAIL | | | LOCATION IS FINE, HOWEVER NEED TO CONFIRM THAT EDGE | | | BUILDING HAS ALTERNATIVE MEANS TO TRANSPORT TRASH BINS | | | TO STAGING AREA. NEED TO CONFIRM THIS ARRANGEMENT WILL | | | WORK FOR ALL PARTIES INVOLVED | | | 37. SATISFIED | | | 38. CONDITION OF APPROVAL. PROVIDE PHOTOMETRIC ANALYSIS | | | PLANS ? TO INCLUDE PUBLIC OPEN SPACE, ALL BUILDING | | | ENTRANCES AND PATHWAYS ? INCLUDING DOG PARK ENTRANCE | | | COORDINATED DURING BUILDING PERMIT PROCESS | | | LANDSCAPE: | | | 39. SATISFIED | | | 40. PARTIALLY SATISFIED. EXISTING OAK TREES ALONG | | | CLEARWATER DRIVE MAY BE ABLE TO BE RELOCATED TO | | | PLANTING BED CLOSER TO CURB- SEE LANDSCAPE COMMENTS. | | | NEED TO COORDINATE WITH ENGINEERING FOR UTILITY LINE | | | PLACEMENT | | | PROPOSED TREES SHALL BE ALONG CURB LINE AS SEWER LINE | | | IS BEING RELOCATED | | | 41. SATISFIED | | | 42. PARTIALLY SATISFIED. SPECIFIC TYPE OF PUBLIC OPEN | | | SPACE AND PRIVATE OPEN SPACE IS REQUIRED. PLEASE | | | INCLUDE SPECIFIC TYPE AND TABLES ILLUSTRATING HOW | | | REQUIREMENTS FOR SPECIFIC OPEN SPACE TYPES HAVE BEEN | | | MET. NEED ADDITIONAL DETAIL TO DETERMINE IF OPEN SPACE | | | IS AN IMPROVEMENT ON SITE. THE INITIAL DESIGN DOES NOT | | | SEEM TO BE A BIG IMPROVEMENT TO PUBLIC SPACE. NEED TO | | | COORDINATE | | | PASSAGEWAY OPEN SPACE DOES NOT WORK FOR THIS SITE. THIS | | | LOCATION OF PUBLIC OPEN SPACE DOES NOT MEET THE | | | DEFINITION OF PASSAGEWAY FROM SECTION 94-109. | | | 43. CONDITIONALLY SATISFIED. PLEASE PRESERVE THE TWO | | | TREES THAT EXIST ON THE WEST SIDE OF THE DRY RETENTION | | | AREA (NEW PROPOSED OPEN SPACE) BY MEANS OF ISLANDS OR | | | SHIFTING/REMOVING SOME PARKING SPACES | | | SATISFIED AS LONG AS RAY CARANCI HAS DETERMINED THAT | | | THE TREES ARE NOT WORTH PRESERVING. | | | 44. PARTIALLY SATISFIED. PROVIDE HARDSCAPE PLAN | | | ILLUSTRATING PROPOSED CONCEPTUAL PAVERS, FOUNTAIN | | | (INCLUDING DEPTH OF FOUNTAIN AND PROTECTIVE BARRIER), | | | PAVER BANDING/CONCRETE BANDING, SEATING OPEN SPACE, | | | ETC. | | | NEED TO SEE MATERIAL EXAMPLES AND DETAILS FOR PAVERS, | | | BANDING, ETC. REQUIRED PRIOR TO DAC (STAFF UNDERSTANDS | | | EXACT COLOR AND MATERIAL CHOICES MAY BE MODIFIED | | | THROUGHOUT BUILDING PERMIT PROCESS, BUT A CONCEPT IS | | | NEEDED) | | | 45. PARTIALLY SATISFIED. LANDSCAPE PLAN SHEET PL-1 DOES | | | NOT SEEM TO ACCOUNT FOR FIRE, IRRIGATION AND WATER | | | ASSEMBLY ADJACENT TO PROPOSED OPEN SPACE ? PLEASE | | | COORDINATE WITH CIVIL PLAN | | | LOW SHRUBS CAN BE PLANTED IN FRONT OF FIRE BACKFLOW, | | | IRRIGATION METER. FROM PAST CASES, THEY CANNOT BE | | | PLANTED IN FRONT OF DOMESTIC BACKFLOW BUT PLEASE | | | CONFIRM WITH PUBLIC UTILITIES. THE SIDEWALK BETWEEN | | | THESE UTILITIES AND THE BACK OF CURB IS APPROXIMATELY | | | 12 FEET ? CAN BE REDUCED TO 8 FEET TO ACCOMMODATE | | | ADDITIONAL LANDSCAPE IN FRONT OF UTILITIES. PLEASE | | | EXAMINE POSSIBILITY AND SEE HOW IT INTERACTS WITH THE | | | REST OF THE PROPOSED PUBLIC OPEN SPACE AND SIDEWALK | | | ALONG CLEARWATER | | | 46. SATISFIED | | | 47. PARTIALLY SATISFIED. ARE TREES PROPOSED ALONG | | | CLEARWATER DRIVE IN A LANDSCAPE BED? THIS IS PREFERRED | | | IF 8-FOOT SIDEWALK CLEARANCE CAN BE MAINTAINED BETWEEN | | | BUILDING FA?ADE AND BED (APPEARS IT CAN) | | | TREES SHALL BE PLANTED ALONG CURB LINE IN PLANTER BED | | | RATHER THAN FA?ADE PLANTING. CONTINUOUS PLANTER BED CAN | | | BE LOCATED ALONG ENTIRE FA?ADE WHERE THERE IS NO | | | CROSSWALK OR CURB CUT | | | 48. SATISFIED | | | 49. PARTIALLLY SATISFIED. CANNOT DETERMINE IF TREES ON | | | NORTH SIDE OF PUBLIC OPEN SPACE ARE EXISTING. STAFF | | | DOES NOT WANT THE EXISTING MATURE TREES AT THIS | | | LOCATION REMOVED | | | CAN TREES K AND L BE PRESERVED? THEY DON?T SEEM TO NEED | | | TO BE REMOVED | | | 50. NOT SATISFIED. ABOVE GROUND UTILITIES ALONG | | | BUILDINGS SOUTH FA?ADE SHALL BE SCREENED WITH LANDSCAPE | | | HEDGE TO BEST EXTENT POSSIBLE. PLEASE INCLUDE IN | | | LANDSCAPE PLAN | | | COORDINATE LANDSCAPE SCREENING AROUND THESE UTILITIES | | | WHEN THEY ARE IN THEIR FINAL APPROVED LOCATION. FOR THE | | | SAKE OF SITE PLAN REVIEW, PLEASE PLACE LOW LANDSCAPE ON | | | ALL SIDES OF THE FDC, FIRE BACKFLOW, IRRIGATION METER, | | | AND ON THREE SIDES OF THE WATER METER AND DOMESTIC | | | BACKFLOW (CANNOT BE PLANTED ON THE ACCESSED SIDE OF | | | WATER METER AND DOMESTIC BACKFLOW). IN THE CASE THAT | | | PUBLIC UTILITIES REQUIRES ANY OF THESE UTILITIES TO BE | | | LOCATED ON THE ROW (NOT WITHIN PRIVATE PROPERTY), | | | PLEASE PLACE UP AGAINST BUILDING WITH FA?ADE PLANTING, | | | OR ALONG CURB LINE SURROUNDING BY PLANTING. CONTINUE | | | COORDINATION WITH ZONING DEPARTMENT | | | 51. SATISFIED | | | 52. SATISFIED. | | | 53. ONGOING. DUE TO THE SITE?S SIZE AND THE REQUEST FOR | | | VARIANCES, THIS PROJECT IS SUBJECT TO DAC REVIEW PRIOR | | | TO COMPLETING PPRC PROCESS | | | 54. ONGOING. APPLICANT SHALL MEET AIPP REQUIREMENTS ? | | | CONTACT SYBILLE WELTER, AIPP COORDINATOR AT | | | [email protected] | | | CIVIL: | | | 55. PARTIALLY SATISFIED. MAINTAIN AND ENHANCE | | | CONNECTION FROM PROPOSED PUBLIC OPEN SPACE TO MULTI | | | MODAL CENTER THROUGH ADA RAMP AND CROSSWALK | | | PLEASE INDICATE EXISTING CROSSWALK AND MAINTAINED | | | CONNECTION ON PLANS | | | 56. PARTIALLY SATISFIED. DO NOT SEE DETAIL FOR WS-8 | | | WATER METER OR WS-11 IRRIGATION METER AS LABELED ON | | | SHEET C-03 | | | SHEET C-12 NOT INCLUDED WITH SUBMITTAL PACKAGE | | | 57. ONGOING. PLEASE NOTE, LOCATION OF ALL ABOVE GROUND | | | UTILITIES, INCLUDING BACKFLOW ASSEMBLIES, WATER METERS, | | | FDC, FIRE BACKFLOWS, GENERATORS, IRRIGATION METERS, | | | ETC. REQUIRE ZONING APPROVAL IN COORDINATION WITH | | | PUBLIC WORKS AND CITY ENGINEERING DEPARTMENT | | | IRRIGATION METER ON PRIVATE PROPERTY. LOCATE GATE | | | VALVES OFF OF PUBLIC SIDEWALK AREA. CAN DCDA BE LOCATED | | | FURTHER WEST TO PROVIDE FOR LANDSCAPE SCREENING BETWEEN | | | SIDEWALK AND DCDA? SAME FOR IRRIGATION RPZ? IN THE CASE | | | THAT PUBLIC UTILITIES REQUIRE ANY OF THESE UTILITIES TO | | | BE LOCATED ON THE ROW (NOT WITHIN PRIVATE PROPERTY), | | | PLEASE PLACE UP AGAINST BUILDING WITH FA?ADE PLANTING, | | | OR ALONG CURB LINE SURROUNDING BY PLANTING. CONTINUE | | | COORDINATION WITH ZONING DEPARTMENT | | | | | | 58. SATISFIED | | | 59. SATISFIED | | | 60. SATISFIED | | | 61. SATISFIED | | | 62. SATISFIED | | | 63. PARTIALLY SATISFIED. PROVIDE CROSS SECTIONS FOR | | | SIDEWALKS, PARALLEL PARKING SPACES, OPEN SPACE AREAS, | | | ETC. PLEASE PROVIDE A PARALLEL CUB CUT ACROSS ALL | | | PARKING GARAGE ENTRANCES, SHOWING SLOPE OF SIDEWALK | | | STAFF WAS NOT CLEAR ? MEANT TO ASK FOR A CROSS SECTION | | | ACROSS THE PARKING GARAGE THAT IS PARALLEL TO | | | CLEARWATER, NOT PARALLEL TO THE GARAGE ENTRANCE DRIVE | | | 64. CONDITION OF APPROVAL. SHOW ALL DOORWAYS ON CIVIL | | | PLANS AND INDICATE HOW GRADE CHANGES ARE BEING | | | ACCOMMODATED. ALL GRADE CHANGES SHOULD OCCUR INTERIOR | | | TO THE BUILDING, NOT ON THE SIDEWALK/ROW | | | TO ENSURE THAT THIS IS MAINTAINED, WILL BE A CONDITION | | | OF APPROVAL FOR BUILDING PERMIT REVIEW | | | NEW COMMENTS OCTOBER 30, 2020: | | | 65. SCAD SHALL BE APPROVED PRIOR TO SITE PLAN APPROVAL. | | | ARCHITECTURE: | | | 66. IS A GATE PROPOSED AT THE SOUTH EGRESS ONLY DRIVE | | | ONTO CLEARWATER? PLEASE INDICATE ON SITE PLAN AND ON | | | ARCHITECTURAL PLANS. PLEASE INCLUDE MATERIAL DETAIL | | | 67. IS A GATE PROPOSED FOR THE ACCESS TO THE PARKING | | | GARAGE? THE RETAIL/COMMERCIAL PARKING SPACES WILL NEED | | | TO BE ACCESSIBLE BY THE GENERAL PUBLIC. PLEASE EXPLAIN | | | HOW THIS WILL WORK | | | 68. PLEASE INCLUDE RENDERINGS SHOWING INTERACTION OF | | | PUBLIC OPEN SPACE WITH PROPOSED BUILDING, AND VIEW FROM | | | NORTHWEST LOOKING SOUTHEAST, AND VIEW FROM SOUTH EAST | | | CORNER LOOKING NORTH WEST. | | | 69. PLEASE NOTE, WINDOW MATERIAL TINTING SHALL MAINTAIN | | | TRANSPARENCY BETWEEN GROUND FLOOR COMMERCIAL SPACES AND | | | EXTERIOR. PLEASE PROVIDE MATERIAL SPEC (UNDERSTANDING | | | THIS MAY CHANGE DURING PERMIT PROCESS, BUT TRANSPARENCY | | | MUST BE MAINTAINED) | | | 70. PLEASE UPDATE VARIANCE TABLE TO REFLECT TWO | | | VARIANCES ? NOT THREE (ONE FOR GROUND FLOOR AND PODIUM, | | | ONE FOR PARKING ABOVE 7TH FLOOR) | | | 71. DOG PARK STILL LABELED ON ARCHITECTURAL PLANS ON | | | SIDE INTERIOR LOT LINE | | | 72. WHAT IS THE FUNCTION OF THE 16?6? SPACE ON NORTH | | | SIDE OF NORTH DRIVEWAY ON CLEARWATER? CAN RETAIL SPACE | | | BE EXTENDED HERE | | | 73. SOME OF THE CONCRETE FINS COULD BE REMOVED IN ORDER | | | TO BETTER REFLECT PLANAR BREAKS AS THEY ARE PROPOSED IN | | | THE EXHIBIT. PLEASE SCHEDULE A CALL WITH URBAN DESIGN | | | TEAM TO DISCUSS | | | 74. PLEASE INCLUDE AN OPAQUE GATE SOMEWHERE APPROPRIATE | | | WITHIN THE SPACE BETWEEN THE EDGE AND PROPOSED 350 | | | PROJECT TO SCREEN THE BACK OF HOUSE/DUMPSTER STAGING | | | AREA FROM THOSE WITHIN THE CIRCULAR DRIVE AND THE | | | PUBLIC VIEW FROM THE ACCESS EASEMENT ROADWAY | | | 75. STAFF RECOMMENDS ANALYZING PROPOSED ENTRANCE TO DOG | | | PARK. LOOKS LIKE THE ONLY WAY TO GET THERE IS THROUGH | | | THE CORRIDOR THAT GOES IN FRONT OF THE GENERATOR ROOMS | | | OR HAVING TO WALK THROUGH THE ASPHALT DUMPSTER STAGING | | | AREA. NOT A ZONING REQUIREMENT BUT A RECOMMENDATION FOR | | | THE TENANT?S ENJOYMENT | | | TRAFFIC: | | | 76. PLEASE UPDATE TRAFFIC STUDY ? NO LONGER LEFT TURN | | | IN TO SOUTH EGRESS DRIVE AND UPDATE IF ONLY FOR LOADING | | | EGRESS (NO LONGER FOR OTHER VEHICULAR EGRESS) | | | LANDSCAPE: | | | 77. OAK TREE PROPOSED VERY CLOSE TO FIRE HYDRANT AT | | | CIRCULAR PARKING ROW LANDSCAPE ISLAND. IS THIS TOO | | | CLOSE? | | | 78. STREET TREES ALONG CURB LINE SHALL BE 20-FOOT | | | PLANTING HEIGHT | | | 79. OVERALL, STAFF FEELS THAT THE PUBLIC OPEN SPACE | | | NEEDS TO BE ENHANCED AND BETTER DESIGNED TO INTERACT | | | WITH THE EXISTING AND PROPOSED BUILDING. A DIFFERENT | | | TYPE OF OPEN SPACE WILL NEED TO BE PICKED AND THE | | | CRITERIA MET. STAFF RECOMMENDS A CONFERENCE CALL WITH | | | THE LANDSCAPE PLANNER AND URBAN DESIGN TO DISCUSS | | | FURTHER | | | CIVIL/SITE: | | | 80. PUBLIC BICYCLE RACK ON CLEARWATER OUTSIDE | | | COMMERCIAL SPACE, PLEASE REORIENT TO BE PARALLEL WITH | | | BUILDING TO FIT 6-FOOT-LONG BICYCLES (LEAVE 24? FROM | | | BUILDING FA?ADE) | | | 81. RE-LABEL GROUND FLOOR UNITS FROM RESIDENTIAL TO | | | LIVE/WORK TO MATCH SITE PLAN | | | 82. PROPOSED CURBING OUTSIDE PARKING GARAGE ENTRANCES | | | ON CLEARWATER DRIVE PREVENT CLEAR SIDEWALK PATH (IF | | | THIS IS A SIDEWALK ALONG THE BUILDING FA?ADE) LEADING | | | TO DOG PARK. SUGGEST PROVIDING FLUSH SIDEWALK WITH | | | GARAGE ENTRANCES | | | 83. ADD LABEL TO PROPOSED STAGING AREA FOR TRASH ? | | | CURRENTLY READS AS ONLY STAGING FOR THE EDGE TRASH. | | | PLEASE CLARIFY THAT THIS IS ALSO PROPOSED STAGING FOR | | | PROPOSED 350 BUILDING. PLEASE ILLUSTRATE NUMBER OF | | | COMPACTORS AND RECYCLING BINS THAT CAN FIT WITHIN THIS | | | STAGING AREA SAFELY ? USE ACTUAL DIMENSIONS OF EDGE | | | COMPACTORS AND PROPOSED 350 COMPACTORS. THIS WILL NEED | | | TO BE REVIEWED BY PUBLIC UTILITIES (MATT HEJAZI) | | | 84. CIVIL PLANS APPEAR TO SHOW WALL AROUND DUMPSTER | | | STAGING AREA BUT DOES NOT APPEAR ON OTHER PLANS. PLEASE | | | CLARIFY | | | 85. CIVIL SHEET C-08 ILLUSTRATES VAULT THOUGH LABELED | | | TO REMOVE ON SHEET C-03. PLEASE CLARIFY | | | 86. PLEASE REMOVE PUMP HOUSE OUTLINE ON SHEET C-08 AND | | | LIGHT POLE THAT IS CURRENTLY LOCATED AT EXISTING OPEN | | | SPACE?S ENTRANCE FROM CLEARWATER DRIVE (IF BEING | | | REMOVED) | | | 87. CAN PROPOSED SSMH #2 BE LOCATED OFF OF THE PUBLIC | | | SIDEWALK? ARE TWO MANHOLES SO CLOSE TO EACH OTHER (SSMH | | | #2 AND SSMH #1 NECESSARY OR CAN ONE BE REMOVED OR | | | RELOCATED? | | | 88. PLEASE REMOVE TRUNCATED DOMES AT PARKING GARAGE | | | ENTRANCES ON CLEARWATER. ONLY INCLUDE AT ROADWAY | | | INTERSECTIONS (PER CITY TRAFFIC ENGINEERING DEPT.) | | | 89. PLEASE AMEND THE CROSS SECTION A-A TO ACCURATELY | | | REFLECT PROPOSED LANDSCAPE AND WALL SEATING | | | 90. PLEASE MATCH WIDTH OF CURB CUTS AND APRONS WITH | | | SITE PLAN | | | 91. CONTINUE 8 FOOT SIDEWALK ENTIRE LENGTH OF PROPERTY | | | AND TRANSITION OUTSIDE PROPERTY (AT PROJECTS SOUTHEAST | | | SIDE) | | | | | | PROPOSED CONDITIONS OF APPROVAL: | | | 92. ALL PORTIONS OF THE PARKING GARAGE SHALL BE PAINTED | | | (CEILING AND WALLS INCLUDING ANY UTILITIES AND PIPING) | | | TO A DEPTH OF 20 FEET. ALL PARKING GARAGE LIGHTING | | | SHALL BE SHIELDED | | | 93. PLEASE NOTE, ALL PROJECTS WITH MICROUNITS SHALL | | | CONTRIBUTE TO THE CITY TROLLEY FUND AT A RATE OF $10 | | | PER MICROUNIT PER MONTH | | | 94. ALL ROOFTOP EQUIPMENT SHALL BE SCREENED TO THE | | | HEIGHT OF THE EQUIPMENT. ALL WALL MOUNTED EQUIPMENT | | | SHALL BE ARCHITECTURALLY SCREENED OR PAINTED TO MATCH | | | BUILDING FA?ADE | | | 95. ALL GRADE CHANGES SHOULD OCCUR INTERIOR TO THE | | | BUILDING, NOT ON THE SIDEWALK/ROW | | | 96. TRANSPARENCY MUST BE MAINTAINED THROUGH CHOICE OF | | | GLASS FOR WINDOWS ALONG GROUND FLOOR | | | SEE OTHER DEPARTMENT COMMENTS FOR ADDITIONAL STANDARD | | | PROPOSED PROVISOS | | | | | | | | | LIZ LEVESQUE, URBAN DESIGN PLANNER | | | 561 822 1426 | | | [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
09-04-2020 |
|
|
Cont ID |
|
| Sent By |
elevesqu |
Date |
09-04-2020 |
Time |
10:14 |
Rev Time |
0.00 |
| Received By |
elevesqu |
Date |
09-04-2020 |
Time |
10:13 |
Sent To |
|
|
| Notes |
| 2020-09-04 10:15:02 | | | | GENERAL COMMENTS: | | | | | | 1. CHANGE ?INFORMAL? TO ?FORMAL? ON COVER SHEET | | | 2. ADDITIONAL INFORMATION IS NECESSARY TO MAKE FINAL | | | DETERMINATION OF SITE CALCULATIONS. | | | A. WHAT ARE THE LEGAL PARAMETERS THAT REGULATE THE | | | MASTER ASSOCIATION? | | | B. . IS DRAINAGE FOR PHASE II ALLOWED WITHIN THE MASTER | | | ASSOCIATION AREA? CAN IT BE LOCATION OUTSIDE PHASE II | | | PARCEL? | | | C. IS EDGE ASSOCIATION CONSENTING FOR OPEN SPACE TO BE | | | OPEN TO THE PUBLIC? ARE THEY AWARE OPEN SPACE PERMITS | | | THE PUBLIC TO ENTER? | | | D. EXTENSION OF BALCONIES INTO EDGE ASSOCIATION | | | PROPERTY ? NEED TO CONFIRM IF PERMITTED | | | E. MEASUREMENT OF SIDE INTERIOR SETBACK AND REAR | | | SETBACK DETERMINED BASED ON HOW PROPERTY LINES WILL BE | | | MODIFIED WITH PROJECT | | | F. HOW WILL INTERNAL DRIVE BE MAINTAINED AND OPERATED? | | | 3. NEED TO DETERMINE BEST WAY TO ORGANIZE SITE DATA FOR | | | CLARITY THAT ALTHOUGH SEPARATE OWNERSHIP AND SEPARATE | | | PROJECT, THIS IS CONSIDERED AN AMENDMENT TO THE EDGE | | | PHASE II PROJECT | | | 4. CAN EXISTING DRAINAGE BE DISENGAGED? | | | 5. NEED TO DETERMINE WHETHER BALCONY ENCROACHMENT INTO | | | SIDE INTERIOR SETBACK SHALL COUNT TOWARDS REQUEST FOR | | | SETBACK VARIANCE | | | 6. SHEET A ? 0.01 | | | A. LABEL STREET NAMES ASSOCIATED WITH THEIR | | | DESIGNATIONS UNDER MIN. ACTIVE USE TABLE | | | B. INCLUDE ACTUAL PROVIDED SETBACK FOR SIDE INTERIOR | | | SOUTH | | | C. INCLUDE VARIANCE TABLE FOR PROPOSED VARIANCES. | | | PLEASE NOTE, SETBACK FOR GROUND FLOOR, PODIUM AND TOWER | | | ARE THREE SEPARATE VARIANCE REQUESTS | | | D. MINIMUM GUEST PARKING FOR MICROUNITS IS 1/20 NOT 0, | | | PLEASE UPDATE IN TABLE | | | 7. IS TENANT STORAGE UNDER FULLY ENCLOSED AND/OR AC? | | | ONLY COUNTS TOWARDS FAR IF IT IS FULLY ENCLOSED AND/OR | | | UNDER AC | | | 8. THE TOTAL AMOUNT OF CAR-SHARE STATIONS MAY BE | | | REDUCED BY ONE CAR-SHARE STATION PER EVERY 13 ON-SITE | | | PARKING SPACES PROVIDED. CAR SHARE STATIONS CAN BE | | | REDUCED BY NUMBER OF PARKING SPACES PROVIDED FOR THE | | | MICROUNITS. DEDUCTION BASED ON CURRENT NUMBERS WOULD BE | | | 9 SPACES, RESULTING IN A NEED FOR 9 CAR SHARE SPACES. | | | 9. FOR STANDARD UNITS, GUEST PARKING AT 1/20 UNITS | | | WOULD REQUIRE 9 GUEST PARKING, NOT 10. PLEASE UPDATE | | | 10. PLEASE REDUCE AMOUNT OF PARKING SPACES AROUND | | | CIRCULAR DRIVE ? STAFF WISHES TO PRESERVE EXISTING ON | | | SITE TREES AND REDUCE THE AMOUNT OF SURFACE PARKING | | | SPACES, ESPECIALLY IF PARALLEL PARKING ON CLEARWATER | | | DRIVE WILL BE UTILIZED FOR RIDE SHARE AND CAR SHARE | | | 11. ARE THE PARKING SPACES AROUND CIRCULAR DRIVE BEING | | | COUNTED TOWARDS PROJECT?S PARKING? ? NEED TO CONFIRM | | | HOW IF OFF SITE. PLEASE SEPARATE IN PARKING DATA TABLE | | | AND INCLUDE SEPARATE LINE FOR PARALLEL PARKING | | | 12. PLEASE SHOW DOUBLE STRIPING OF PARKING SPACES | | | WITHIN PARKING GARAGE AND CONFIRM COMPLIANCE WITH | | | ADDITIONAL WIDTH WHEN ADJACENT TO WALLS. | | | 13. NUMBER OF PARKING SPACES ON 2ND FLOOR DOES NOT | | | INCLUDE PARKING RAMP, PLEASE AMEND (SHEET A1.01) | | | 14. REDUCE NUMBER OF DRIVEWAY AND CURB CUTS FROM | | | PROJECT. ELIMINATE FROM CLEARWATER DRIVE IF POSSIBLE. | | | NO MORE THAN ONE ON CLEARWATER IF ALL CANNOT BE | | | ELIMINATED. REDUCE INTERNAL TO TWO LANES ONLY | | | 15. CLEARLY INDICATE WHERE 6% SLOPE ENDS AND 12.5% | | | SLOPE BEGINS ON RAMP FROM 2ND TO 3RD FLOOR AND CHECK TO | | | MAKE SURE THERE ARE NO PARKING SPACES ON 12.5% SLOPE | | | 16. PLEASE CLARIFY WHERE 8TH LEVEL OF PARKING GARAGE | | | ENDS. APPEARS TO BE A WALL ABOVE RAMP FROM 7TH TO 8TH | | | FLOOR. IF THIS IS A DEAD-END, A FULL SPACE TURN AROUND | | | IS NEEDED PLUS A THREE FOOT SPACE FOR THE VEHICLE TO | | | BACK INTO IN ORDER TO TURN AROUND. UNLESS THE SPACES | | | ARE DESIGNATED? | | | 17. PARKING NUMBER LISTED ON SHEET A 1.03 FOR 8TH FLOOR | | | DOES NOT APPEAR TO BE RIGHT, PLEASE CHECK (MAKE SURE | | | DOES NOT COUNT FOR SPACES ALREADY INCLUDED IN 7TH FLOOR | | | CALCULATIONS | | | 18. BICYCLE PARKING: | | | A. FOR RESIDENTIAL USES ? REQUIRED BICYCLE PARKING IS | | | ONE SPACE PER 15 PROVIDED PARKING SPACES NOT 20. 22 | | | SPACES REQUIRED, PLEASE UPDATE ACCORDINGLY | | | B. 2 BICYCLE PARKING SPACES REQUIRED FOR PROPOSED | | | COMMERCIAL SPACE (1/15 PROVIDED PARKING SPACES) | | | C. 1 BICYCLE SPACE PER 100 FEET OF STREET FRONTAGE FOR | | | PUBLIC USE. THIS WOULD COUNT OPEN SPACE, RESULTING IN 5 | | | REQUIRED PUBLIC BICYCLE RACKS (NOT INCLUDING | | | MICROMOBILITY STATION) | | | D. BASED ON CURRENT SF AND UNIT BREAKDOWN, STAFF COUNTS | | | 148 REQUIRED BICYCLE SPACES (143 INSIDE AND COVERED, 5 | | | OUTSIDE FOR PUBLIC) | | | E. INCLUDE BICYCLE RACK DETAIL FOR INTERIOR BICYCLE | | | ROOM BIKE RACKS (ARE THESE WALL MOUNTED?). NEED TO | | | INDICATE EXACT SPACING REQUIRED FOR INTERIOR RACKS | | | F. WHERE IS ENTRANCE INTO BICYCLE STORAGE FOR TENANTS? | | | 19. CORRECT LABEL ON SHEET A0.02 FOR LEVELS 2- 9 FAR | | | FLOOR PLANS ( CURRENTLY LISTS LEVEL 2-81) | | | 20. 30% OF 317?5? IS 95.25 FOR REQUIRED ACTIVE USE, | | | PLEASE UPDATE ON SHEET A 0.03 | | | 21. GROUND FLOOR RESIDENTIAL SHALL BE RAISED A MINIMUM | | | OF 18 INCHES ABOVE SIDEWALK ? PLEASE ILLUSTRATE | | | COMPLIANCE | | | 22. SUGGEST ADDITIONAL DOORWAY FROM OPEN SPACE INTO | | | BUILDING MANAGEMENT TO MEET INTENT OF ACTIVE USE | | | INTERACTION WITH OPEN SPACE WITHIN CLD DISTRICT | | | 23. PLEASE INCLUDE FOLLOWING EXHIBITS ILLUSTRATING | | | COMPLIANCE: | | | A. TRANSPARENCY | | | B. PLANAR BREAKS ? DOES NOT APPEAR TO MEET PLANAR BREAK | | | ALONG CLEARWATER DRIVE | | | C. HORIZONTAL PROJECTIONS | | | D. FAR TABLE WITH CALCULATIONS FOR EACH FLOOR AND FOR | | | TOTAL | | | 24. SHOW ADJACENT PROPERTY CURB LINES, PARKING LOTS, | | | STRUCTURES ETC. ON SITE PLAN AND CIVIL PLANS | | | 25. HOW WILL TRASH PICKUP WORK FOR NEW BUILDING? WHERE | | | WILL EXISTING TRASH FOR EDGE BUILDING BE RELOCATED? | | | 26. PLEASE PROVIDE COLOR ELEVATIONS WITH DETAILS FOR | | | MATERIALS. PLEASE INCLUDE EXAMPLE IMAGES OF MATERIALS | | | FOR BETTER CLARIFICATION. PLEASE INCLUDE EXHIBIT FOR | | | PARKING GARAGE SCREENING WHICH CLEARLY SHOWS SPACING IN | | | THE PROPOSED GARAGE SCREENING AND MATERIAL (EXAMPLE | | | IMAGES WOULD BE HELPFUL) AND DEPTH OF PANELS, | | | DIFFERENCE IN PANEL DEPTHS. NEED ADDITIONAL DETAIL TO | | | BE ABLE TO REVIEW AND ENSURE THAT PARKING GARAGE | | | SCREENING IS EFFICIENT | | | 27. PLEASE ADD FA?ADE ARTICULATION TO NORTH FA?ADE | | | PARKING GARAGE AREA. PLEASE NOTE, NO BLANK WALLS ARE | | | PERMITTED THAT CAN BE SEEN FROM ADJACENT STREETS, OR | | | ADJACENT PROPERTIES (SECTION 94-109 ? BLANK WALL | | | DEFINITION). ARCHITECTURAL TREATMENT SHALL SCREEN | | | NON-ACTIVE USES THROUGH A COMBINATION OF TWO OR MORE | | | TREATMENTS INCLUDING, BUT NOT LIMITED TO, THE USE OF | | | MATERIALS AND CONSTRUCTION ASSEMBLIES; THE CONTINUATION | | | OF FENESTRATION PATTERNS, ARCHITECTURAL FEATURES, | | | ARTICULATION AND RHYTHM; THE APPLICATION OF | | | ARCHITECTURAL SCREENS, MESHES, LOUVERS, AND GLASS, ETC. | | | THIS DOES NOT INCLUDE PAINT AND FAUX TREATMENTS OR | | | SCORING OR PROJECTIONS LESS THAN FOUR INCHES IN DEPTH, | | | WIDTH OR HEIGHT. | | | 28. NORTH FLOOR PLAN WINDOW LOCATIONS DO NOT MATCH | | | NORTH ELEVATION- PLEASE COORDINATE. CONSIDER ADDITIONAL | | | HORIZONTAL ELEMENT ALONG NORTH FA?ADE OF CORNER UNIT | | | D-3 TO HELP BREAK UP HEIGHT OF BLANK WALL SECTIONS AT | | | THIS CORNER. | | | 29. PLEASE INCLUDE DOORS IN ELEVATION PLANS | | | 30. WHAT IS THICKNESS OF WHITE BANDING THROUGHOUT THE | | | FACADES? WILL THIS BE THICK ENOUGH TO CREATE DEPTH TO | | | THE FEATURE AS INTENDED? | | | 31. PLEASE SUBMIT COLOR RENDERINGS FROM GROUND VIEW | | | PERSPECTIVE. INCLUDE LANDSCAPE AS PROPOSED, AT PLANTING | | | HEIGHT FOR ACCURATE CONSTRUCTION REPRESENTATION. | | | 32. PLEASE INCLUDE ARCHITECTURAL TREATMENT ON EAST | | | ELEVATION TO BIKE STORAGE AND STORAGE TO ALLEVIATE | | | BLANK WALL ALONG THIS FA?ADE. | | | 33. PLEASE SUBMIT CONTEXTUAL ELEVATIONS | | | 34. CONSIDER WHETHER THE PARAPET HEIGHT WILL SCREEN ALL | | | ROOF-MOUNTED EQUIPMENT ? ROOF MOUNTED EQUIPMENT SHALL | | | BE SCREENED TO THE HEIGHT OF THE EQUIPMENT THROUGH | | | PARAPET OR OTHER MEANS | | | 35. BLANK WALL ON FLOORS 10-17 ON EAST ELEVATION (STAIR | | | AND ELEVATOR AND NORTH SIDE TOWER) ? NEEDS ADDITIONAL | | | TREATMENT FOR NONACTIVE USE. CONSIDER WINDOWS ON NORTH | | | TOWER FACING EDGE BUILDING OR OTHER TREATMENT | | | 36. WHERE IS THE ACCESS TO THE DOG PARK PROPOSED? WILL | | | IT CONNECT TO CLEARWATER DRIVE? PLEASE PROVIDE MORE | | | DETAIL | | | 37. IS EXISTING ASPHALT ADJACENT TO EXISTING DUMPSTER | | | ENCLOSURE BEING REMOVED? PLEASE CLARIFY ON ALL PLANS | | | 38. PROVIDE PHOTOMETRIC ANALYSIS PLANS ? TO INCLUDE | | | PUBLIC OPEN SPACE, ALL BUILDING ENTRANCES AND PATHWAYS | | | ? INCLUDING DOG PARK ENTRANCE | | | | | | LANDSCAPE: | | | 39. PLEASE SUBMIT TREE DISPOSITION PLAN | | | 40. EXISTING OAK TREES ALONG CLEARWATER DRIVE MAY BE | | | ABLE TO BE RELOCATED TO PLANTING BED CLOSER TO CURB- | | | SEE LANDSCAPE COMMENTS. NEED TO COORDINATE WITH | | | ENGINEERING FOR UTILITY LINE PLACEMENT | | | 41. SHOW EXISTING PROPERTY LINES ON LANDSCAPE PLANS ? | | | LANDSCAPE PROPOSED ON EDGE ASSOCIATION PROPERTY CANNOT | | | COUNT TOWARDS LANDSCAPE CALCULATIONS FOR PROJECT- CHECK | | | WITH RAY | | | 42. SPECIFIC TYPE OF PUBLIC OPEN SPACE AND PRIVATE OPEN | | | SPACE IS REQUIRED. PLEASE INCLUDE SPECIFIC TYPE AND | | | TABLES ILLUSTRATING HOW REQUIREMENTS FOR SPECIFIC OPEN | | | SPACE TYPES HAVE BEEN MET. NEED ADDITIONAL DETAIL TO | | | DETERMINE IF OPEN SPACE IS AN IMPROVEMENT ON SITE. THE | | | INITIAL DESIGN DOES NOT SEEM TO BE A BIG IMPROVEMENT TO | | | PUBLIC SPACE. NEED TO COORDINATE | | | 43. PLEASE PRESERVE THE TWO TREES THAT EXIST ON THE | | | WEST SIDE OF THE DRY RETENTION AREA (NEW PROPOSED OPEN | | | SPACE) BY MEANS OF ISLANDS OR SHIFTING/REMOVING SOME | | | PARKING SPACES | | | 44. PROVIDE HARDSCAPE PLAN ILLUSTRATING PROPOSED | | | CONCEPTUAL PAVERS, FOUNTAIN (INCLUDING DEPTH OF | | | FOUNTAIN AND PROTECTIVE BARRIER), PAVER | | | BANDING/CONCRETE BANDING, SEATING OPEN SPACE, ETC. | | | 45. LANDSCAPE PLAN SHEET PL-1 DOES NOT SEEM TO ACCOUNT | | | FOR FIRE, IRRIGATION AND WATER ASSEMBLY ADJACENT TO | | | PROPOSED OPEN SPACE ? PLEASE COORDINATE WITH CIVIL PLAN | | | 46. COORDINATE WITH ARCHITECTURAL/SITE PLAN FOR DOORWAY | | | LOCATIONS ALONG DOG PARK | | | 47. ARE TREES PROPOSED ALONG CLEARWATER DRIVE IN A | | | LANDSCAPE BED? THIS IS PREFERRED IF 8-FOOT SIDEWALK | | | CLEARANCE CAN BE MAINTAINED BETWEEN BUILDING FA?ADE AND | | | BED (APPEARS IT CAN) | | | 48. KEEP CLEAR SIDEWALK OF EIGHT FEET THROUGH ENTIRE | | | PROJECT WIDTH INCLUDING AREA BETWEEN PUBLIC OPEN SPACE | | | AND PARALLEL PARKING SPACES AND BETWEEN WALK UP GARDENS | | | AND CURB LINE | | | 49. CANNOT DETERMINE IF TREES ON NORTH SIDE OF PUBLIC | | | OPEN SPACE ARE EXISTING. STAFF DOES NOT WANT THE | | | EXISTING MATURE TREES AT THIS LOCATION REMOVED | | | 50. ABOVE GROUND UTILITIES ALONG BUILDINGS SOUTH FA?ADE | | | SHALL BE SCREENED WITH LANDSCAPE HEDGE TO BEST EXTENT | | | POSSIBLE. PLEASE INCLUDE IN LANDSCAPE PLAN | | | 51. OFF SITE LANDSCAPE IN EDGE ASSOCIATION PROPERTY | | | (ALONG EXISTING DUMPSTER ENCLOSURE AREA) ? WHETHER THIS | | | CAN BE COUNTED TOWARDS MITIGATION OR LANDSCAPE | | | CALCULATIONS DEPENDS ON HOW ORIGINAL ASSOCIATION | | | DOCUMENTS WERE WRITTEN AND ORIGINAL PLAN FOR PHASE I | | | AND II (SEE COMMENT #2) | | | 52. PLEASE PROVIDE DETAIL OF WALK UP GARDEN- SEE TABLE | | | IV-7 AND DEFINITION OF WALK UP GARDEN IN SECTION | | | 94-109. WALK UP GARDENS CANNOT BE COVERED | | | 53. DUE TO THE SITE?S SIZE AND THE REQUEST FOR | | | VARIANCES, THIS PROJECT IS SUBJECT TO DAC REVIEW PRIOR | | | TO COMPLETING PPRC PROCESS | | | 54. APPLICANT SHALL MEET AIPP REQUIREMENTS ? CONTACT | | | SYBILLE WELTER, AIPP COORDINATOR AT [email protected] | | | | | | CIVIL: | | | 55. MAINTAIN AND ENHANCE CONNECTION FROM PROPOSED | | | PUBLIC OPEN SPACE TO MULTI MODAL CENTER THROUGH ADA | | | RAMP AND CROSSWALK | | | 56. DO NOT SEE DETAIL FOR WS-8 WATER METER OR WS-11 | | | IRRIGATION METER AS LABELED ON SHEET C-03 | | | 57. PLEASE NOTE, LOCATION OF ALL ABOVE GROUND | | | UTILITIES, INCLUDING BACKFLOW ASSEMBLIES, WATER METERS, | | | FDC, FIRE BACKFLOWS, GENERATORS, IRRIGATION METERS, | | | ETC. REQUIRE ZONING APPROVAL IN COORDINATION WITH | | | PUBLIC WORKS AND CITY ENGINEERING DEPARTMENT | | | 58. PARKING SPACES SHALL BE DOUBLE STRIPED | | | 59. BUILDING FOOT PRINT DOES NOT EXACTLY MATCH | | | ARCHITECTURAL PLANS ? PLEASE CHECK AND AMEND AS | | | NECESSARY | | | 60. FDC SHALL BE WALL MOUNTED WHENEVER POSSIBLE, | | | SUBJECT TO FIRE DEPARTMENT APPROVAL | | | | | | 61. NUMBER OF PARALLEL PARKING SPACES ALONG CLEARWATER | | | DRIVE DOES NOT MATCH SITE PLAN ? PLEASE COORDINATE | | | 62. RELOCATED WATER METER, FIRE BACKFLOW AND ASSEMBLY, | | | ETC. ? WILL NEED TO COORDINATE WITH PUBLIC WORKS, FIRE | | | DEPARTMENT AND PUBLIC UTILITIES TO FIND BEST LOCATION | | | FOR THESE SERVICES AS THEY ARE BEING RELOCATED. THESE | | | TYPES OF UTILITIES SHOULD NOT BE WITHIN PUBLIC OPEN | | | SPACE. WILL NEED TO DISCUSS AND FIND BEST SOLUTION AND | | | ALLOW FOR CONTINUOUS SIDEWALK ADJACENT TO PARALLEL | | | PARKING SPACES | | | 63. PROVIDE CROSS SECTIONS FOR SIDEWALKS, PARALLEL | | | PARKING SPACES, OPEN SPACE AREAS, ETC. PLEASE PROVIDE A | | | PARALLEL CUB CUT ACROSS ALL PARKING GARAGE ENTRANCES, | | | SHOWING SLOPE OF SIDEWALK | | | 64. SHOW ALL DOORWAYS ON CIVIL PLANS AND INDICATE HOW | | | GRADE CHANGES ARE BEING ACCOMMODATED. ALL GRADE CHANGES | | | SHOULD OCCUR INTERIOR TO THE BUILDING, NOT ON THE | | | SIDEWALK/ROW | | | PROPOSED CONDITIONS OF APPROVAL: | | | 65. ALL PORTIONS OF THE PARKING GARAGE SHALL BE PAINTED | | | (CEILING AND WALLS INCLUDING ANY UTILITIES AND PIPING) | | | TO A DEPTH OF 20 FEET. ALL PARKING GARAGE LIGHTING | | | SHALL BE SHIELDED | | | 66. PLEASE NOTE, ALL PROJECTS WITH MICROUNITS SHALL | | | CONTRIBUTE TO THE CITY TROLLEY FUND AT A RATE OF $10 | | | PER MICROUNIT PER MONTH | | | 67. ALL ROOFTOP EQUIPMENT SHALL BE SCREENED TO THE | | | HEIGHT OF THE EQUIPMENT. ALL WALL MOUNTED EQUIPMENT | | | SHALL BE ARCHITECTURALLY SCREENED OR PAINTED TO MATCH | | | BUILDING FA?ADE | | | | | | SEE OTHER DEPARTMENT COMMENTS FOR ADDITIONAL STANDARD | | | PROPOSED PROVISOS | | | |
|
|
| |