Plan Review Details - Project Z20070022
Plan Review Stops For Project Z20070022
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status N Date   Cont ID  
Sent By llouie Date   Time 10:09 Rev Time  
Received By llouie Date   Time   Sent To  
Notes
***NONE***

Review Stop ENG - PPRC ENGINEERING - PPRC
Rev No 1 Status P Date 07-23-2020 Cont ID  
Sent By rrossano Date 07-23-2020 Time   Rev Time  
Received By rrossano Date 07-23-2020 Time   Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time  
Received By   Date   Time   Sent To  
Notes
***NONE***

Review Stop L LANDSCAPING
Rev No 1 Status P Date 07-30-2020 Cont ID  
Sent By rcaranci Date 07-30-2020 Time 14:10 Rev Time 0.00
Received By rcaranci Date 07-30-2020 Time 14:10 Sent To  
Notes
2020-07-30 14:10:37NO COMMENTS

Review Stop PARK PARKING
Rev No 1 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time  
Received By   Date   Time   Sent To  
Notes
***NONE***

Review Stop POLICE POLICE
Rev No 1 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time  
Received By   Date   Time   Sent To  
Notes
***NONE***

Review Stop PW PUBLIC WORKS
Rev No 1 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time  
Received By   Date   Time   Sent To  
Notes
***NONE***

Review Stop STORM STORMWATER
Rev No 2 Status P Date 08-27-2020 Cont ID  
Sent By tward Date 08-27-2020 Time 22:29 Rev Time 0.00
Received By tward Date 08-27-2020 Time 22:29 Sent To  
Notes
***NONE***

Review Stop STORM STORMWATER
Rev No 1 Status F Date 07-31-2020 Cont ID  
Sent By tward Date 07-31-2020 Time 09:22 Rev Time 0.00
Received By tward Date 07-31-2020 Time 09:22 Sent To  
Notes
2020-07-31 09:22:29THE FOLLOWING COMMENTS ARE FROM THE REVIEW OF THE
 7/22/2020 SUBMITTAL REVIEW PACKAGE.
  
 1. SECTION B-B
 A. ADJACENT PARKING SPACE IS 15.5 FEET OR 33.5 FEET,
 NOT 16 FEET PER DIMENSIONS SHOWN ON PGD PLAN.
 B. PART OF THE EAST PAVEMENT AREA SLOPES TOWARD THE
 CURB AND GUTTER.
  
 2. SECTION C-C
 A. THE RETAINING WALL WAS MOVED 5 FEET TO THE WEST AND
 A STEEL RAIL PROPOSED IN THE WIDER LANDSCAPE BUFFER.
 B. SHOW IF THERE NEEDS TO BE A BERM ALONG THE WEST
 PROPERTY LINE
  
 3. CONFIRM THE LOSS OF STORAGE IN THE DETENTION AREA
 ALONG THE WEST SIDE OF THE SITE DUE TO THE RELOCATION
 OF THE RETAINING WALL WILL NOT AFFECT THE REQUIRED
 STORAGE FOR STORMWATER RUNOFF.
  
 4. UPDATE THE UTILITIES ON THE LANDSCAPE PLANS.
  
 5. SHOW THE UTILITIES ON THE LIGHTING PLAN TO AVOID
 CONFLICTS. FOR EXAMPLE, THERE IS A PROPOSED LIGHT POLE
 ALONG THE EAST PROPERTY LINE THAT IS FURTHER FROM THE
 BACK OF CURB THAN OTHERS. THIS MAY HAVE BEEN TO AVOID A
 CATCH BASIN THAT USED TO BE PROPOSED IN THIS AREA BUT
 HAS SINCE BEEN RE-DESIGNED.
  
 6. SHEET SP-2 SECTION C WEST LANDSCAPE BUFFER. UPDATE
 TO SHOW 2 FOOT PARKING OVERHANG, STEEL RAILING AND
 WIDER LANDSCAPE BUFFER. THE PARKING AREA IS AN INVERTED
 CROWN (V-SHAPED). THE LOW POINT OF THE PAVEMENT IS
 ALONG THE EDGE OF THE DRIVE AISLE.
  
 7. THE JERSEY BARRIER SHOWN IN THE THE "CROSS SECTIONS
 MARK UP EXHIBIT.PDF"EXHIBIT SHOULD NOT ENCROACH INTO
 THE 2 FOOT OVERHANG OF THE PARKING SPACE.
  
 TRACY WARD, PE
 SENIOR STORMWATER ENGINEER
 ENGINEERING SERVICES DEPARTMENT
 561-494-1120 (O)
 561-351-0510 (M)
 [email protected]
  
  

Review Stop SURVEY SURVEYING
Rev No 1 Status P Date 07-29-2020 Cont ID  
Sent By vnoel Date 07-29-2020 Time 10:19 Rev Time  
Received By vnoel Date   Time   Sent To  
Notes
***NONE***

Review Stop TRAFFIC TRAFFIC ENGINEERING
Rev No 2 Status P Date 08-26-2020 Cont ID  
Sent By   Date 08-26-2020 Time   Rev Time 0.00
Received By   Date   Time   Sent To  
Notes
2020-08-26 10:59:11TRAFFIC COMMENTS:
  
 NO FURTHER COMMENTS
  
 VALERIO ORICCHIO
 CITY TRANSPORTATION ENGINEER
 561-494-1092
 [email protected]
  

Review Stop TRAFFIC TRAFFIC ENGINEERING
Rev No 1 Status F Date 07-30-2020 Cont ID  
Sent By   Date 07-30-2020 Time   Rev Time  
Received By   Date 07-17-2020 Time   Sent To  
Notes
2020-07-30 10:16:28TRAFFIC COMMENTS:
 1. PROVIDE SIDEWALK AND ADA RAMPS AT THE BULB OUT ON
 THE NORTH-EAST SIDE OF THE PROPERTY
  
 VALERIO ORICCHIO
 CITY TRANSPORTATION ENGINEER
 561-494-1092
 [email protected]
  

Review Stop Z ZONING
Rev No 2 Status P Date 08-26-2020 Cont ID  
Sent By llouie Date 08-26-2020 Time   Rev Time 0.00
Received By llouie Date 08-26-2020 Time   Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 07-29-2020 Cont ID  
Sent By llouie Date 07-29-2020 Time   Rev Time  
Received By llouie Date 07-29-2020 Time   Sent To  
Notes
2020-07-29 10:11:011.) SHOW SETBACK DISTANCE OF THE RELOCATED LIGHT POLE
 FIXTURES TO THE EAST PROPERTY LINE. ALL POLE FIXTURES
 MUST BE SETBACK A MINIMUM OF 5 FT. FROM THE PROPERTY
 LINE. [ZLDR S.94-145]
  
 2.) SOME LIGHT POLE FIXTURES SEEM TO BE IN CONFLICT
 WITH THE 2 FT. VEHICULAR CURB OVERHANG (I.E. ALONG THE
 SOUTH AND EAST PROPERTY LINES, ETC.). PLEASE ENSURE ALL
 POLE FIXTURES ARE APPROPRIATELY PLACED SO THAT THEY ARE
 NOT IN CONFLICT WITH THE PARKING OF VEHICLES.
  
 3.) IN SITE PLAN NOTE #4 IN THE JUSTIFICATION
 STATEMENT, THE NOTE INDICATES THAT A STEEL CABLE
 BARRIER HAS BEEN ADDED TO THE TOP OF THE WALL ALONG THE
 WEST PROPERTY LINE? THE SITE PLAN SEEMS TO SHOW THE
 STEEL CABLE BARRIER INSIDE OF THE WALL. PLEASE CLARIFY.
  
 4.) IF THE STEEL CABLE BARRIER IS LOCATED INSIDE THE
 WALL: PLEASE SHOW HEIGHT AND/OR PROVIDE A DETAIL ON
 SHEET SP-2.
  
 5.) PLEASE NOTE THAT THE SIGN AREA DETAIL HAS CHANGED
 (REFERENCE: PERMIT #20070357). THE SIGN DETAIL SHOULD
 MATCH THE SIGN DETAIL IN THE APPROVED SIGN PERMIT FOR
 CONSISTENCY.
  
 6.) THE PROJECT NUMBER IS: PB 1670M/Z20070022 (CHANGES
 EVERY TIME A NEW CASE NUMBER IS ISSUED FOR TRACKING
 PURPOSES, SO IT IS NO LONGER PB 1670K/Z19050025).
  
 7.) ANY CHANGES IN THE PLANS WILL NEED TO BE REFLECTED
 IN ALL OTHER PLANS (SITE PLAN, LANDSCAPE PLAN AND
 PHOTOMETRIC PLAN) FOR CONSISTENCY.
  
  
 INSTRUCTIONS FOR RESUBMITAL:
  
 * PLEASE PROVIDE RESPONSES TO REVIEW COMMENTS IN
 WRITTEN FORMAT.
  
 * WHEN RESUBMITTING, PLEASE PROVIDE THREE (3) PAPER
 COPIES, ONE (1) REDUCED COPY IN 11 INCHES X 17 INCHES,
 AND AN ELECTRONIC COPY OF ALL PLANS.
  
 * PLEASE NOTE THAT CHANGES ON THE RESUBMITTED PLANS MAY
 RESULT IN ADDITIONAL COMMENTS.
  
 * PLEASE NOTE THAT YOU WILL BE PERMITTED ONE (1)
 RESUBMITTAL AT NO ADDITIONAL COST. IF PREVIOUSLY-ISSUED
 COMMENTS CONTINUE TO NOT BE SUFFICIENTLY ADDRESSED, THE
 APPLICANT WILL BE ASSESSED A RESUBMITTAL FEE. SUCH FEE
 WILL BE 20 PERCENT ($60.00) OF THE ORIGINAL APPLICATION
 FEE.
  
 * CONTACT LINDA LOUIE @ (561) 822-1458 IF THERE ARE
 QUESTIONS.
  

  Print


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved