Plan Review Details - Project Z20070016
| Plan Review Stops For Project Z20070016 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
03-02-2021 |
|
|
Cont ID |
|
| Sent By |
rbrown |
Date |
03-02-2021 |
Time |
19:16 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
03-02-2021 |
Time |
19:16 |
Sent To |
|
|
| Notes |
| 2021-03-02 19:18:00 | DEVELOPMENT SERVICES DEPARTMENT, BUILDING DIVISION, | | | COMMENTS: | | | | | | 1. THIS REVIEW IS A CURSORY REVIEW AS IT RELATES TO THE | | | SITE. IT IS NOT A REVIEW FOR FULL COMPLIANCE WITH | | | FLORIDA BUILDING CODE. THE FOLLOWING COMMENTS ARE TO BE | | | ADDRESSED FOR THE BUILDING PERMIT APPLICATION. | | | | | | 2. DEMOLITION OF THE EXISTING BUILDING. AN ASBESTOS | | | SURVEY SHALL BE PERFORMED AND AN ASBESTOS ABATEMENT | | | REPORT SUBMITTED TO THE HEALTH DEPARTMENT PALM BEACH | | | COUNTY OFFICE. CONTACT ALEX ORTEGA AT (561) 837-5963, | | | OR BY EMAIL: [email protected] | | | | | | 3. BUILDING SIZE. WHEN SUBMITTED FOR BUILDING PERMIT, | | | THE PLANS SHALL SHOW THAT THE TYPE OF CONSTRUCTION FOR | | | THE BUILDINGS WILL BE IN ACCORDANCE WITH THE HEIGHT, | | | AREA AND OCCUPANCY LIMITATIONS IN CHAPTER 5 OF THE | | | FLORIDA BUILDING CODE. | | | | | | 4. GREASE INTERCEPTOR. A GREASE INTERCEPTOR WILL BE | | | REQUIRED IF THERE IS A FOOD SERVICE ESTABLISHMENT IN | | | THE PROPOSED STORE. FOR INFORMATION ON THE REQUIRED | | | TYPE, SIZE AND LOCATION, PLEASE CONTACT TIM LARGE, | | | CHIEF PLUMBING INSPECTOR, DEVELOPMENT SERVICES | | | DEPARTMENT, AT (561) 805-6692, OR BY EMAIL: | | | [email protected] | | | | | | 5. SEPARATE PERMITS REQUIRED. ALL APPLICABLE PERMITS | | | AND SUB-PERMITS MUST BE OBTAINED BEFORE COMMENCING THE | | | WORK. SEPARATE PERMITS, PLANS AND FEES, ARE REQUIRED | | | FOR SIGNS, GAS SYSTEMS, GENERATORS, FIRE ALARM SYSTEMS, | | | FIRE SPRINKLER AND OTHER FIRE SUPPRESSION SYSTEMS, | | | GREASE INTERCEPTORS, SITE LIGHTING, SITE LANDSCAPE, | | | SITE IRRIGATION, ETC. | | | | | | 6. BUILDING ADDRESS. EACH SEPARATE BUILDING, AND UNIT | | | WITH AN INDEPENDENT ENTRANCE FROM THE STREET, SHALL | | | HAVE A SEPARATE ADDRESS ASSIGNED BASED ON THE LOCATION | | | OF THE BUILDING ENTRANCE. FOR STREET ADDRESSING, | | | CONTACT CAROLINE PUELL, ADDRESSING COORDINATOR, AT | | | (561) 805 6659, OR BY EMAIL: [email protected] | | | | | | 7. ART IN PUBLIC PLACES. THIS PROJECT WILL BE SUBJECT | | | TO ART IN PUBLIC PLACES (AIPP) ASSESSMENT. FOR ADVICE | | | ON THE PROVISION OF PUBLIC ARTWORK IN LIEU OF THE AIPP | | | ASSESSMENT, CONTACT SYBILLE WELTER, ART IN PUBLIC | | | PLACES COORDINATOR, AT (561) 822-1521, OR BY EMAIL: | | | [email protected] | | | | | | ROBERT BROWN | | | BUILDING OFFICIAL | | | TEL: 561 805 6652 | | | EMAIL: [email protected] | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
12-09-2020 |
|
|
Cont ID |
|
| Sent By |
rbrown |
Date |
12-09-2020 |
Time |
21:02 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
12-09-2020 |
Time |
21:02 |
Sent To |
|
|
| Notes |
| 2020-12-09 21:17:24 | DEVELOPMENT SERVICES DEPARTMENT, BUILDING DIVISION, | | | COMMENTS: | | | | | | 1. THIS REVIEW IS A CURSORY REVIEW AS IT RELATES TO THE | | | SITE. IT IS NOT A REVIEW FOR FULL COMPLIANCE WITH | | | FLORIDA BUILDING CODE. THE FOLLOWING COMMENTS ARE TO BE | | | ADDRESSED FOR THE BUILDING PERMIT APPLICATION. | | | | | | 2. DEMOLITION OF THE EXISTING BUILDING. AN ASBESTOS | | | SURVEY SHALL BE PERFORMED AND AN ASBESTOS ABATEMENT | | | REPORT SUBMITTED TO THE HEALTH DEPARTMENT PALM BEACH | | | COUNTY OFFICE. CONTACT ALEX ORTEGA AT (561) 837-5963, | | | OR BY EMAIL: [email protected] | | | | | | 3. ACCESSIBLE ROUTE FROM BRANDSMART TO THE PROPOSED BJS | | | WAREHOUSE. SITE PLAN SHEET C101.0. SHOW AT LEAST ONE | | | ACCESSIBLE ROUTE, COMPLYING WITH SECTIONS 206.2 AND | | | 402.2 OF FLORIDA ACCESSIBILITY CODE, CONNECTING | | | ACCESSIBLE BUILDING OR FACILITY ENTRANCES WITH ALL | | | ACCESSIBLE SPACES AND ELEMENTS WITHIN THE BUILDING OR | | | FACILITY | | | | | | 4. PROPOSED NUMBER OF ACCESSIBLE PARKING SPACES AT | | | BRANDSMART STORE . SITE PLAN SHEET C101.0. THE PROPOSED | | | CHANGES IN THE PARKING FOR THE BRANDSMART STORE WOULD | | | RESULT IN INSUFFICIENT ACCESSIBLE PARKING SPACES. THERE | | | ARE 421 TOTAL PARKING SPACES PROPOSED SO 9 ACCESSIBLE | | | PARKING SPACES ARE REQUIRED. ONLY 8 ACCESSIBLE PARKING | | | SPACES ARE PROPOSED. THE MINIMUM NUMBER OF ACCESSIBLE | | | PARKING SPACES PROVIDED SHALL BE IN ACCORDANCE WITH | | | SECTION 208.2 OF FLORIDA ACCESSIBILITY CODE. | | | | | | 5. BUILDING SIZE. WHEN SUBMITTED FOR BUILDING PERMIT, | | | THE PLANS SHALL SHOW THAT THE TYPE OF CONSTRUCTION FOR | | | THE BUILDINGS WILL BE IN ACCORDANCE WITH THE HEIGHT, | | | AREA AND OCCUPANCY LIMITATIONS IN CHAPTER 5 OF THE | | | FLORIDA BUILDING CODE. | | | | | | 6. GREASE INTERCEPTOR. A GREASE INTERCEPTOR WILL BE | | | REQUIRED IF THERE IS A FOOD SERVICE ESTABLISHMENT IN | | | THE PROPOSED STORE. FOR INFORMATION ON THE REQUIRED | | | TYPE, SIZE AND LOCATION, PLEASE CONTACT TIM LARGE, | | | CHIEF PLUMBING INSPECTOR, DEVELOPMENT SERVICES | | | DEPARTMENT, AT (561) 805-6692, OR BY EMAIL: | | | [email protected] | | | | | | 7. SEPARATE PERMITS REQUIRED. ALL APPLICABLE PERMITS | | | AND SUB-PERMITS MUST BE OBTAINED BEFORE COMMENCING THE | | | WORK. SEPARATE PERMITS, PLANS AND FEES, ARE REQUIRED | | | FOR SIGNS, GAS SYSTEMS, GENERATORS, FIRE ALARM SYSTEMS, | | | FIRE SPRINKLER AND OTHER FIRE SUPPRESSION SYSTEMS, | | | GREASE INTERCEPTORS, SITE LIGHTING, SITE LANDSCAPE, | | | SITE IRRIGATION, ETC. | | | | | | 8. BUILDING ADDRESS. EACH SEPARATE BUILDING, AND UNIT | | | WITH AN INDEPENDENT ENTRANCE FROM THE STREET, SHALL | | | HAVE A SEPARATE ADDRESS ASSIGNED BASED ON THE LOCATION | | | OF THE BUILDING ENTRANCE. FOR STREET ADDRESSING, | | | CONTACT CAROLINE PUELL, ADDRESSING COORDINATOR, AT | | | (561) 805 6659, OR BY EMAIL: [email protected] | | | | | | 9. ART IN PUBLIC PLACES. THIS PROJECT WILL BE SUBJECT | | | TO ART IN PUBLIC PLACES (AIPP) ASSESSMENT. FOR ADVICE | | | ON THE PROVISION OF PUBLIC ARTWORK IN LIEU OF THE AIPP | | | ASSESSMENT, CONTACT SYBILLE WELTER, ART IN PUBLIC | | | PLACES COORDINATOR, AT (561) 822-1521, OR BY EMAIL: | | | [email protected] | | | | | | ROBERT BROWN | | | BUILDING OFFICIAL | | | TEL: 561 805 6652 | | | EMAIL: [email protected] | | | |
|
|
| Review Stop |
ENG - PPRC |
ENGINEERING - PPRC |
| Rev No |
4 |
Status |
P |
Date |
06-21-2021 |
|
|
Cont ID |
|
| Sent By |
rrossano |
Date |
06-21-2021 |
Time |
|
Rev Time |
0.00 |
| Received By |
rrossano |
Date |
06-21-2021 |
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
ENG - PPRC |
ENGINEERING - PPRC |
| Rev No |
3 |
Status |
F |
Date |
05-25-2021 |
|
|
Cont ID |
|
| Sent By |
rrossano |
Date |
05-25-2021 |
Time |
|
Rev Time |
0.00 |
| Received By |
rrossano |
Date |
05-25-2021 |
Time |
|
Sent To |
|
|
| Notes |
| 2021-05-29 09:56:51 | THE FOLLOWING COMMENTS ARE FROM MARK HURLEY, FIELD | | | CUSTOMER SERVICE SUPERVISOR, WPB PUBLIC UTILITIES, | | | PLEASE CONTACT 561-494-2262 OR [email protected]: | | | FOLLOWUPS TO RESPONSES: | | | | | | 12. IF FIRELINE PIPING IS GOING TO RUN THROUGH | | | POND/LAKE, THEN BOTH CONTAINMENT FIRELINE BACKFLOW | | | ASSEMBLIES WOULD NEED TO BE UPGRADED TO RPDA TYPES. | | | | | | PAGE 9 KIMLEY-HORN.COM 1615 SOUTH CONGRESS AVENUE, | | | SUITE 201, DELRAY BEACH, FL 33445 561 330 2345 | | | RESPONSE: FIRELINE PIPES RUNNING UNDER DRY DETENTION | | | AREA HAVE BEEN REVISED TO BE RPDA TYPE, REFER TO SHEET | | | C501.0. | | | | | | -DURING SITE MEETING, ENGINEER VERIFIED NO INCREASED | | | HAZARD DUE TO LINER. I BELIEVE THE INTENTION WAS TO | | | KEEP USING BOTH EXISTING FIRELINE DDCV IF THEY ARE NOT | | | BEING RELOCATED. | | | | | | NEW COMMENTS AS FOLLOWS: | | | | | | -THERE MAY BE LANDSCAPING CONFLICTS WITH UTILITIES BUT | | | CANNOT TELL FOR SURE BECAUSE LANDSCAPING PLAN DOES NOT | | | SHOW UTILITIES ON IT. PLEASE SUBMIT SEPARATE PLAN SHEET | | | WITH LANDSCAPING OVERLAID ON UTILITIES SO CAN VERIFY | | | BETTER. | | | | | | -PRIOR ASKED ABOUT IRRIGATION AND RESPONSE REFERENCED | | | IRRIGATION PLAN. CANNOT FIND THE IRRIGATION PLAN ? | | | PLEASE SUBMIT IT. | | | | | | -CIVIL PLANS HAD DUPLICATE STANDARD DETAILS INCLUDE FOR | | | SMALL BACKFLOW ASSEMBLY. PLEASE REMOVE ONE OF THE THEM. | | | | | | -IS EXISTING PRIVATE LIFT STATION SUFFICIENT FOR | | | ADDITION OF BJ?S? | | | | | | -GREASETRAP FOR BRANDSMART LOOKS LIKE IT IS LOCATED IN | | | THE ROAD. DID NOT KNOW IF THAT WOULD COMPLICATE | | | MAINTENANCE. IS LOCATION ACCEPTABLE? | | | | | | -COULD ONLY FIND A SEWER LATERAL FOR BRANDSMART GOING | | | TO A GREASETRAP. IF THERE IS ANOTHER ONE, PLEASE SHOW | | | AND LABEL IT ON SEWER PLAN. | | | | | | -LABEL BOTH FPL STATIONS ON THE WATER PLAN. IF THERE | | | ARE ANY EASEMENTS FOR THE FPL STATIONS, THEN SHOW AND | | | LABEL THOSE ALSO. | | | | | | -SHOW AND LABEL PROPOSED MONUMENT SIGNS ON THE WATER | | | PLANS. (THEY ARE SHOWN ON THE SITE PLAN FOR REFERENCE). | | | | | | -FOR FORMAL ENGINEERING SUBMITTAL: SHOW AND LABEL | | | EXISTING FIRELINE AROUND SOUTHERN AND WESTERN PORTIONS | | | OF BRANDSMART ALL THE WATER TO THE WATER MAIN ? (SOME | | | PORTIONS ARE MISSING), SHOW BETTER ON INSET B THE | | | CONNECTION FROM NEW 4 INCH PIPE TO 2.5 INCH BACKFLOW | | | ASSEMBLIES. | | | | | | -MAKE SURE WATER PLAN DOMESTIC BACKFLOW ASSEMBLY | | | INFORMATION NEAR NE ROW MATCHES INSET A. SHOULD NOT BE | | | DDCV OR RPDA ? SHOULD BE RP TYPE. BELIEVE THOSE WERE | | | PROPOSED TO BE REPLACED. | | | | | | -SAN SEWER MH NORTHEAST OF MH NO.1 IS NOT LABELED WITH | | | ELEVATION INFO. | | | | | | -PIPE SIZING FOR FIRE HYDRANT ON INSET B DOES NOT SEEM | | | TO MATCH CROSSING INFORMATION AND PLAN SIZING. | | | | | | -DEMOLITION PLAN IS AMBIGUOUS ON HOW THE WATER PIPING | | | WILL BE DEMOLISHED. FOR INSTANCE THE EXISTING 10 WATER | | | PIPE. PLEASE INCLUDE MORE DETAIL ON THE PLAN THE METHOD | | | OF DEMOLITION. | | | -ON DEMO PLAN ADD PIPE MATERIAL TYPE TO LABEL FOR | | | EXISTING 10 WATER PIPE THAT IS TO BE DEMOLISHED. | | | | | | |
|
|
| Review Stop |
ENG - PPRC |
ENGINEERING - PPRC |
| Rev No |
2 |
Status |
F |
Date |
03-03-2021 |
|
|
Cont ID |
|
| Sent By |
rrossano |
Date |
03-03-2021 |
Time |
|
Rev Time |
0.00 |
| Received By |
rrossano |
Date |
03-03-2021 |
Time |
|
Sent To |
|
|
| Notes |
| 2021-03-03 10:28:33 | THE FOLLOWING COMMENTS ARE FROM MARK HURLEY, FIELD | | | CUSTOMER SERVICE SUPERVISOR, WPB PUBLIC UTILITIES, | | | PLEASE CONTACT 561-494-2262 OR [email protected]: | | | -NEAR THE NORTHWEST ENTRANCE ON THE WATER PLAN THERE | | | SHOWS A PROPOSED EASEMENT. WHAT TYPE IS IT? | | | | | | -THERE SHOWS PROPOSED GREASE TRAP, SEWER MANHOLE, SEWER | | | PIPING, AND FORCE MAIN PIPING IN POND/LAKE. IS THAT A | | | CONFLICT FOR MAINTENANCE, CONTAMINATION, AND | | | INFILTRATION? | | | | | | -PLEASE DRAW ARROWS ON FORCE MAIN SHOWING DIRECTION OF | | | FLOW. | | | | | | -WILL THE TWO VAULT METERS BE CONNECTED WITH PIPING TO | | | FORM A LOOPED SYSTEM? | | | | | | -IF DOMESTIC VAULT METER IS RELOCATED, IT NEEDS TO | | | CHANGE TO ABOVE-GROUND INSTALLATION WITHOUT A VAULT AND | | | LABELED ABOVE-GROUND. | | | | | | -IF THE EXISTING DOMESTIC BACKFLOW ASSEMBLIES ARE NOT | | | LEAD-FREE COMPLIANT, RECOMMEND REPLACING THEM. | | | | | | -CONSIDER DUAL/PARALLEL BACKFLOW ASSEMBLIES ON DOMESTIC | | | WATER SERVICES TO REDUCE WATER OUTAGES DURING BACKFLOW | | | ASSEMBLY MAINTENANCE. | | | | | | -PROPOSED 2INCH BACKFLOW ASSEMBLY LOOKS TO BE IN | | | CONFLICT LOCATION WITH EXISTING ELECTRIC UTILITY. | | | PLEASE RELOCATE SLIGHTLY SOUTHWEST. | | | | | | -WILL THE NORTHWEST VAULT METER ONLY FEED THE DUAL | | | 2.5INCH RPZ FOR BRANDSMART? | | | | | | -ON WHICH SHEET WAS THE NOTE ADDED THAT LEAKING | | | BACKFLOW ASSEMBLIES NEED TO BE REPAIRED? | | | | | | -FOR FORMAL ENGINEERING SUBMITTAL: LABEL THE SIZE OF | | | THE PROPOSED RPZ FOR NEW 2INCH METER, LABEL THE WATER | | | MAIN PIPE MATERIAL TYPE ON EXECUTIVE. LABEL THE | | | FIRELINE POINT OF SERVICE VALVES UPSTREAM OF THE | | | FIRELINE BACKFLOW ASSEMBLIES, SHOW AND LABEL THE | | | FIRELINE WATER SERVICE PIPING FROM THE WATER MAIN WITH | | | PIPE SIZE AND MATERIAL TYPE, SHOWS ALL WATER MAIN GATE | | | VALVES ON EXECUTIVE. | | | | | | -IF FIRELINE PIPING IS GOING TO RUN THROUGH POND/LAKE, | | | THEN BOTH CONTAINMENT FIRELINE BACKFLOW ASSEMBLIES | | | WOULD NEED TO BE UPGRADED TO RPDA TYPES. | | | | | | -VERIFY BOTH FIRELINE WATER SERVICE PIPES WILL BE | | | CONNECTED TO FORM A LOOP SYSTEM. | | | | | | -SOME TREES APPEAR TO BE CLOSE TO THE CONTAINMENT | | | BACKFLOW ASSEMBLIES. VERIFY TREE ROOTS WILL NOT IMPACT | | | PROPERTY OWNER?S WATER PIPING AND BACKFLOW ASSEMBLIES. | | | | | | -WILL NEW DOMESTIC WATER SERVICE PIPE FOR BJ THAT RUNS | | | THROUGH POND/LAKE PRESENT A MAINTENANCE PROBLEM FOR | | | PROPERTY OWNER? | | | | | | -IF THE FIRELINE UTILITY BILLING ACCOUNT HOLDER HAD | | | NONPAYMENT OR BACKFLOW COMPLIANCE ISSUES THAT RESULTED | | | IN THE FIRELINE WATER SERVICES BEING SHUT OFF, THEN | | | BOTH BUSINESSES WOULD BE AFFECTED. | | | | | | -THE EXISTING FIRELINE CONTAINMENT BACKFLOW ASSEMBLIES | | | ARE SHOWN AS 8INCHES, BUT A 10INCH ISOLATION DCDA FOR | | | BJ IS PROPOSED IN ADDITION TO EXISTING 8INCH ISOLATION | | | DCDA FOR BRANDSMART. IS THAT ACCEPTABLE? | | | | | | -IS THE EXISTING 1INCH WATER SERVICE LINE SUFFICIENT | | | FOR BOTH THE GAS STATION AND LIFT STATION? | | | |
|
|
| Review Stop |
ENG - PPRC |
ENGINEERING - PPRC |
| Rev No |
1 |
Status |
F |
Date |
12-01-2020 |
|
|
Cont ID |
|
| Sent By |
rrossano |
Date |
12-01-2020 |
Time |
|
Rev Time |
|
| Received By |
rrossano |
Date |
12-01-2020 |
Time |
|
Sent To |
|
|
| Notes |
| 2020-12-03 08:47:09 | 1. THE CITY OF WEST PALM BEACH HAS A NUMBER OF | | | REGULATIONS AND PERMIT REQUIREMENTS WHICH DIRECTLY | | | AFFECT THE DEVELOPMENT AND INSTALLATION OF WATER AND | | | WASTEWATER UTILITIES WITHIN THE CITY. TO VIEW | | | DEVELOPMENT PERMIT SUBMITTAL REQUIREMENTS AND OTHER | | | ENGINEERING RELATED DOCUMENTS, OPEN A BROWSER IN CHROME | | | AND GO TO: WWW.WPB.ORG/ENGDOCS . TO LOGIN, UNDER | | | ?EMAIL? ENTER [email protected] ; UNDER ?PASSWORD? ENTER | | | SIMPLE321# | | | THERE ARE 4 PAGES OF AVAILABLE ENGINEERING DOCUMENTS | | | FOR YOUR USE. | | | 2. CODE OF ORDINANCES, CITY OF WEST PALM BEACH, | | | FLORIDA, CODIFIED THROUGH ORD. NO. 4183-08, ADOPTED | | | SEPT. 22, 2008. (SUPPLEMENT NO. 18) CHAPTER 90 | | | UTILITIES, ARTICLE I. SEC. 90-7. | | | POLICY REGARDING EXTENSION OF WATER OR SEWER SERVICE | | | FACILITIES OF THE CITY: | | | THE WATER AND WASTEWATER SERVICE AGREEMENTS AND THE | | | CONSTRUCTION PERMITS ADDRESS RESERVATION OF CAPACITY | | | BASED ON USAGE, METER SIZE AND FEES, DESIGN STANDARDS, | | | BACKFLOW PREVENTION, FIRE SERVICE AND IRRIGATION. | | | 3. AS OF DECEMBER 20, 2015, THE CITY OF WEST PALM BEACH | | | CROSS-CONNECTION CONTROL MANUAL HAS BEEN REVISED, | | | STATING "ALL BACKFLOW DEVICES MUST BE LEAD-FREE". FOR | | | MORE INFORMATION, OPEN A BROWSER IN CHROME AND GO TO: | | | WWW.WPB.ORG/ENGDOCS .TO LOGIN, UNDER ?EMAIL? ENTER | | | [email protected] ; UNDER ?PASSWORD? ENTER SIMPLE321# | | | CROSS-CONNECTION CONTROL MANUAL IS ON PAGE 4. | | | 4. PLEASE SUBMIT A FORMAL AS-BUILT REQUEST FOR ALL CITY | | | OF WEST PALM BEACH-OWNED UTILITIES WITHIN THE PUBLIC | | | RIGHT OF WAY FOR THE ENTIRE EXTENT OF THE LIMITS OF | | | YOUR PROJECT. IDENTIFY TYPE OF UTILITY, LOCATION, PIPE | | | MATERIAL, AGE AND SIZE. PLEASE CONTACT JANICE TARBILL | | | IN THE WPB ENGINEERING SERVICES DEPARTMENT AT | | | [email protected] OR 561-494-1040 FOR FURTHER | | | ASSISTANCE. | | | 5. PLANS SHALL SHOW PROPOSED LOCATIONS AND DIMENSIONS | | | OF ALL WATER, STORMWATER, AND SANITARY AND SEWER LINES, | | | INCLUDING STUBS TO EACH PROPERTY LINE FOR WATER AND | | | SANITARY SEWERS, THE MAKE AND MODEL OF ALL VALVES, | | | METERS, AND OTHERS DEVICES TO BE INSTALLED ON THE | | | SYSTEM, CATCH BASINS, CULVERTS, DITCHES INCLUDING | | | GRADES, PIPES SIZES, MATERIALS, ELEVATIONS, | | | ASSUMPTIONS, CALCULATIONS, INVERT ELEVATIONS FOR ALL | | | INLETS AND MANHOLES AND PROFILES OF SANITARY SEWER | | | LINES. ALL AVAILABLE ELEVATION SHALL BE SHOWN ON THE | | | PROFILE VIEW. DIRECTION OF FLOW SHALL BE SHOWN ON PLAN | | | VIEW ON PLAN VIEW FOR ALL SANITARY AND STORM SEWERS. | | | PLEASE SHOW SLOPE % ON ALL SANITARY LINES AND CALL OUT | | | MATERIAL. ADDITIONALLY, PLAN VIEW SHALL SHOW ALL | | | EXISTING AND PROPOSED UNDERGROUND UTILITY LAYOUT, | | | INCLUDING FIBER OPTIC, ELECTRIC, GAS, AND CABLEVISION & | | | TELECOMMUNICATION FACILITIES LOCATED ON THE | | | RIGHT-OF-WAY. PROVIDE PROFILE AND CLEARANCES AT ALL | | | UTILITY CROSSINGS. | | | 6. CUT AND CAP UTILITIES NOT IN USE, AND REMOVE ANY | | | ABANDONED UTILITY LINES LARGER THAN 2 INCHES FROM CITY | | | ROW. | | | 7. PLEASE SUBMIT COMPLETED LOS ANALYSIS SUMMARY TABLE | | | DIRECTLY TO ENGINEERING (SHEET 33 OF CITY OF WPB | | | DEVELOPMENT APPLICATION). | | | 8. PROVIDE CALCULATIONS ON PLANS OF EXISTING AND | | | PROPOSED DEMANDS FOR WATER & SEWER (AVERAGE, MAXIMUM | | | AND PEAK) AND FIRE FLOW DEMANDS. CALCULATIONS SHALL BE | | | PER FAC 64E-6 FOR SEWER AND PER FAC 64-E.008 FOR WATER. | | | 9. SHOW VERTICAL DATUM AND DATUM CONVERSION INFORMATION | | | (NAVD 88 AND NGVD 29). | | | 10. PROVIDE CCTV VIDEO OF EXISTING SANITARY SEWER AND | | | STORMWATER ALONG ENTIRE PROJECT FRONTAGE. | | | 11. PLEASE PROVIDE CALCULATIONS OF REVISED PERVIOUS AND | | | IMPERVIOUS CALCULATIONS FOR THE PROPOSED IMPACTED | | | AREAS. | | | 12. PROVIDE ONSITE CLEANOUTS NEAR PROPERTY LINE FOR | | | PROPOSED SANITARY LATERALS. | | | 13. PLEASE LABEL WATER LINES AS PRIVATE WHERE | | | APPLICABLE. | | | 14. PLEASE PROVIDE ENLARGED VIEW ON PLANS OF PROPOSED | | | LOCATION OF WATER METER AND BACKFLOW PREVENTION. | | | 15. COORDINATE WITH MARK HURLEY, FIELD CUSTOMER SERVICE | | | SUPERVISOR WITH CITY OF WPB PUBLIC UTILITIES, REGARDING | | | PLACEMENT OF BACKFLOW DEVICES AND WATER METERS. CONTACT | | | HIM AT 561-494-2262 OR [email protected] | | | 16. PROVIDE DEDICATED UTILITY EASEMENTS TO ALLOW ACCESS | | | FOR CITY PERSONNEL TO PROPOSED UTILITY WATER METERS. | | | | | | THE FOLLOWING COMMENTS ARE FROM MARK HURLEY, FIELD | | | CUSTOMER SERVICE SUPERVISOR, WPB PUBLIC UTILITIES, | | | PLEASE CONTACT 561-494-2262 OR [email protected]: | | | | | | -ALL CURRENT WATER SERVICES AROUND BRANDSMART AT | | | EXECUTIVE CENTER HAVE UTILITY BILLS IN BRANDSMART?S | | | NAME AND ON SITE PIPING LOOKS TO BE OWNED BY THEM. THE | | | PROPOSED PROPERTY LINES AND WATER USAGE IS PRECARIOUS | | | BECAUSE PRIVATELY-OWNED PIPING IS CROSSING PROPERTY | | | LINES, AND WATER USE IN SOME INSTANCES APPEARS TO BE | | | COMING FROM METERED WATER SERVICES THE USER WOULD NOT | | | PAY FOR. TO PREVENT PRACTICAL AND LEGAL CONFUSION AND | | | PROBLEMS IN THE FUTURE, RECOMMEND WATER SERVICES AND | | | PIPING TO BE DESIGNED IN CONJUNCTION WITH THE PROPERTY | | | LINES, SUCH THAT THE PIPING AND WATER USAGE IS | | | CONTAINED TO EACH PROPERTY. | | | -REMOVAL OF EXISTING FIRE HYDRANTS WOULD REQUIRE THE | | | APPROVAL OF CITY WPB FIRE MARSHAL. | | | -THERE ARE SEVERAL FIRE HYDRANTS ON THE WATER PLANS | | | THAT DO NOT HAVE NOTES ON WHAT IS HAPPENING TO THEM. | | | PLEASE ADD LABELING IF THEY ARE REMAINING OR BEING | | | REMOVED. | | | -C501.0 APPEARS TO BE MISSING THE EXISTING DOMESTIC | | | VAULT WATER SERVICE. PLEASE ADD TO PLAN AND LABEL. | | | -C501.1 APPEARS TO BE MISSING A LARGE DOMESTIC WATER | | | SERVICE. PLEASE ADD TO PLAN AND LABEL. | | | -LABEL PRIVATE FIRELINES. NOTE THAT FIRELINES MAY ONLY | | | BE USED FOR FIREFIGHTING PURPOSES AND CANNOT BE TAPPED | | | FOR THINGS LIKE HOSE BIBS. VERIFY THAT NOT HAPPENING | | | WITH AREA AROUND PROPOSED GAS STATION. | | | -ON SHEET C501.0, PROPOSED METER IS IN SIDEWALK. CANNOT | | | INSTALL METER IN SIDEWALK. RELOCATE TO GRASS AREA AND | | | ADD UTILITY EASEMENT IF ON PRIVATE PROPERTY. | | | -ADD NOTE TO PLAN TO COORDINATE WATER UTILITY WORK SUCH | | | THAT DOWNTIME/OUTAGES OF WATER SERVICES AND FIRELINES | | | ARE MINIMIZED. | | | -ADD NOTE TO PLAN TO NOTIFY WPB FIRE DEPARTMENT IF ANY | | | FIRELINE OR FIRE HYDRANT IS RENDERED NONFUNCTIONAL OR | | | TAKEN OUT OF SERVICE TEMPORARILY. | | | -CANNOT DISTINGUISH WATER SERVICES AT CITY POINT OF | | | SERVICE. ADD SEPARATE DETAILED BLOWUP PLANS SHOWING THE | | | AREAS AROUND THE WATER METERS AND BACKFLOW ASSEMBLIES. | | | -APPEARS SOME BACKFLOW ASSEMBLIES AND WATER SERVICES | | | ARE MISSING FROM WATER PLANS. PLEASE ADD AND LABEL. | | | -SEVERAL EXISTING BACKFLOW ASSEMBLIES ON SITE ARE | | | LEAKING AND NEED REPAIR. ADD NOTE TO PLAN THAT ANY | | | LEAKING BACKFLOW ASSEMBLIES NEED TO BE REPAIRED OR | | | REPLACED BY PROJECT COMPLETION. | | | -ADD WATER DEMAND CALCULATIONS TO WATER PLANS. | | | -WATER SERVICE STANDARD DETAILS ARE OLD REVISION. NEED | | | UPDATE TO NEWEST REVISION FOR ANY THAT WILL BE USED. | | | NEED INCLUDE WATER SERVICE STANDARD DETAILS FOR SMALL | | | WATER SERVICE AND SMALL BACKFLOW ASSEMBLY. | | | -PROPOSED PROPERTY LINE FOR GAS STATION IS NOT | | | CONNECTING TO BJ?S MAIN PROPERTY. THIS COULD BE | | | PROBLEMATIC IF BRANDSMART DOES NOT ALLOW ACCESS OR | | | BUILDS SOMETHING THAT WOULD CUT OFF ACCESS. | | | -PLEASE VERIFY IF BJ?S WILL HAVE FIRE SPRINKLERS INSIDE | | | BUILDING. | | | -DID NOT SEE SEPARATE METERED IRRIGATION WATER SERVICE | | | FOR BJ?S. WILL ONE BE NEEDED? | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
12-07-2020 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
12-07-2020 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
12-02-2020 |
Time |
14:44 |
Sent To |
|
|
| Notes |
| 2020-12-07 14:46:52 | THE FOLLOWING COMMENTS WERE SUBMITTED BY PETER LEDUC, | | | FIRE MARSHAL, BUREAU OF FIRE PREVENTION, WEST PALM | | | BEACH FIRE RESCUE. | | | | | | THIS REVIEW CAN ONLY BE CONSIDERED PRELIMINARY AS THE | | | DRAWINGS THAT WERE REVIEWED WERE NOT COMPLETE. | | | ADDITIONAL COMMENTS CAN BE EXPECTED WHEN FULL DRAWINGS | | | ARE SUBMITTED FOR PERMIT. | | | | | | THE FIRE PREVENTION BUREAU HAS NO OBJECTIONS TO THE | | | PROPOSED PROJECT. | | | | | | 1. CONSTRUCTION, DEMOLITION, AND RENOVATION TO COMPLY | | | WITH NFPA 241. EXTRA ATTENTION SHALL BE GIVEN TO THE | | | PERMITTING AND LOCATION OF CONSTRUCTION TRAILERS. A | | | PERMIT IS REQUIRED FOR ANY CONSTRUCTION TRAILER RELATED | | | TO THIS PROJECT. SEPARATION DISTANCES FROM MAIN | | | STRUCTURES AS WELL AS OTHER TRAILERS SHALL BE CLOSELY | | | MONITORED FOR THE REQUIREMENTS OF FIRE SPRINKLER | | | PROTECTION. | | | | | | 2. SITE ACCESS AND EXIT POINTS ARE TO BE CLEARLY | | | IDENTIFIED AND MAINTAINED FOR EMERGENCY VEHICLES DURING | | | ALL CONSTRUCTION ACTIVITIES. | | | | | | 3. THE BUILDING ADDRESS SHALL BE CLEARLY VISIBLE FROM | | | ALL ACCESS ROADWAYS, INCLUDING DURING CONSTRUCTION. | | | ADDRESS NUMBERS SHALL CONTRAST WITH THEIR BACKGROUND | | | AND SHALL NOT BE LESS THAN SIX (6) INCHES IN HEIGHT | | | WITH A ONE (1) INCH STROKE FOR ALL BUILDINGS. | | | | | | 4. DURING CONSTRUCTION, TRASH AND DEBRIS IS TO BE | | | REMOVED FROM THE SITE DAILY OR MORE OFTEN TO REDUCE THE | | | ACCUMULATION OF POTENTIAL LIFE AND FIRE SAFETY HAZARDS. | | | | | | 5. THE CONSTRUCTION OF THE BUILDING SHALL COMPLY WITH | | | THE 6TH EDITION OF THE FLORIDA FIRE PREVENTION CODE, | | | INCLUDING NFPA 1 & 101, AND ALL ASSOCIATED FIRE CODES. | | | | | | 6. FOR PLAN REVIEW SUBMITTAL, PLEASE INCLUDE THE | | | OCCUPANCY TYPE, PER THE FLORIDA FIRE PREVENTION CODE. | | | | | | 7. FOR PLAN REVIEW SUBMITTAL, PLEASE ENSURE THAT A FIRE | | | LOAD CALCULATION IS INCLUDED AND THAT ADEQUATE WATER | | | SUPPLY IS EXISTING OR WILL BE PROVIDED. | | | | | | 8. ALL EXISTING AND NEW FIRE HYDRANTS PLANNED FOR THIS | | | DEVELOPMENT SHALL BE CLEARLY INDICATED AND IDENTIFIED | | | ON THE PLAN AND CLOSELY COORDINATED WITH THE BUREAU OF | | | FIRE PREVENTION. | | | | | | THE PROPOSED LOCATIONS OF THE FIRE HYDRANT AND FDC ARE | | | ACCEPTABLE WITH ANY CHANGES CLOSELY COORDINATED WITH | | | THE BUREAU OF FIRE PREVENTION. | | | | | | 9. PROVIDE FOR A FIRE SPRINKLER AND/OR FIRE ALARM PER | | | THE APPLICABLE OCCUPANCY CODE. FOR ANY LIFE SAFETY | | | ENGINEERED SYSTEM, I.E FIRE SPRINKLER AND FIRE ALARM, | | | ENSURE THEY COMPLY WITH THE REQUIREMENTS OF FS 61G AND | | | SUBMITTED WITH THE MASTER PERMIT. | | | | | | 9A) THE LOCATION OF ANY APPLICABLE DDCV AND FIRE LINE | | | LOCATIONS SHALL MEET THE REQUIREMENTS OF NFPA 24 AND | | | SHALL BE COORDINATED WITH THE OFFICE OF FIRE MARSHAL, | | | THE CITY'S ENGINEERS OFFICE, THE LANDSCAPE PLANNER, AND | | | THE CITY'S PLANNING AND ZONING OFFICE. | | | | | | 10. COMPLETE LIFE SAFETY PLANS FOR EACH OCCUPANCY SHALL | | | BE PROVIDED THAT ILLUSTRATE OCCUPANT LOADS, TRAVEL | | | DISTANCES, COMMON PATHS OF TRAVEL, DEAD-END CORRIDORS, | | | EXIT SIGNS, EMERGENCY LIGHTING, EXITS LEADING TO A | | | PUBLIC WAY, FIRE EXTINGUISHER LOCATIONS, AND ALL FIRE | | | SAFETY FEATURES AND EQUIPMENT. | | | | | | 11. IT IS HIGHLY RECOMMENDED (REQUIRED WITH FIRE | | | SPRINKLER SYSTEM) THAT A KNOX BOX WITH KEYS FOR ENTRY | | | DOOR LOCKS BE PROVIDED FOR 24 HOUR EMERGENCY ACCESS. | | | | | | 12. PLEASE PROVIDE FOR TWO-WAY RADIO COMMUNICATION | | | COVERAGE PER NFPA 1, CHAPTER 11, BUILDING SERVICES; | | | 11.10 TWO-WAY RADIO ENHANCEMENT SERVICES; 11.10.1 IN | | | ALL NEW AND EXISTING BUILDINGS, MINIMUM RADIO SIGNAL | | | STRENGTH FOR FIRE DEPARTMENT COMMUNICATIONS SHALL BE | | | MAINTAINED AT A LEVEL DETERMINED BY THE AHJ. | | | | | | 13.THE BUREAU'S APPROVAL OF THIS SUBMITTED PROJECT DOES | | | NOT CONSTITUTE ITS FINAL REVIEW OR APPROVAL. | | | | | | 14. THE BUREAU SHALL REVIEW ALL SUBMITTED BUILDING | | | PLANS AT THE APPROPRIATE TIME AND IN ACCORDANCE WITH | | | THE REQUIREMENTS OF ALL APPLICABLE CODES AND STANDARDS. | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
5 |
Status |
P |
Date |
07-16-2021 |
|
|
Cont ID |
|
| Sent By |
aburnett |
Date |
07-16-2021 |
Time |
16:46 |
Rev Time |
0.00 |
| Received By |
aburnett |
Date |
07-16-2021 |
Time |
16:46 |
Sent To |
|
|
| Notes |
| 2021-07-16 16:48:03 | FROM: ANDREW BURNETT, LANDSCAPE PLANNER 561-822-1462 | | | PROJECT: BJ?S AT BRANDSMART CPD Z20070016 | | | JULY 16, 2021 | | | I HAVE REVIEWED THE ABOVE REFERENCED PETITION, AND | | | PROVIDE THE FOLLOWING COMMENTS: | | | | | | 1. SATISFIED. DESIGN GUIDELINES: | | | ? THE EXCEPTION TO THE LANDSCAPE BUFFER FOR WATER | | | BODIES OR I-95 IS NOT SUPPORTED BY STAFF. THE PERIMETER | | | OF THE BRANDSMART PD MUST HAVE THE REQUIRED BUFFER AS | | | STATED. | | | ? BUFFERS MAY BE ADJUSTED TO AVOID UTILITY EASEMENT | | | OVERLAP THAT WOULD PREVENT THE REQUIRED LANDSCAPING | | | FROM BEING ALLOWED. THIS IS REINFORCED BY THE EASEMENT | | | REQUIREMENT NOT BEING ALLOWED TO COUNT TOWARD BUFFER | | | REQUIREMENT. | | | ? ALL LANDSCAPE BUFFERS MUST MEET ALL THE REQUIREMENTS | | | OF ARTICLE XIV ?LANDSCAPING, LAND CLEARING, TREE | | | PROTECTION AND ARTIFICIAL TURF?. | | | ? ALL BUILDINGS MODIFIED OR ADDED MUST MEET THE 30 | | | PERCENT LINEAR FOOTAGE REQUIREMENT FOR FOUNDATION | | | LANDSCAPING. | | | THE DESIGN GUIDELINES ARE NO LONGER NEEDED FOR | | | LANDSCAPE ITEMS. NOW THAT THE SUBDIVISION REQUEST ONLY | | | CREATES 2 LOTS, CODE REQUIREMENTS CAN BE MET, OR A | | | WAIVER REQUESTED. | | | | | | 2. WAIVER REQUESTS. | | | ? SATISFIED. #1 SHOULD READ: PROPOSED -WAIVE THE FIVE | | | FOOT BUFFER REQUIREMENT FOR INTERIOR LOT LINES. | | | ? SATISFIED. #5 UP TO18 PARKING SPACES IN A ROW FOR | | | NEW PARKING AREAS WOULD HAVE TO PROVIDE TREE CANOPY IN | | | SOME OTHER WAY TO MEET THE INTENT OF 94-443(C). OPTIONS | | | ARE CURRENTLY AVAILABLE IN THE CODE TO ALLOW UP TO 12 | | | SPACES IN A ROW BY EXPANDING THE LANDSCAPE ISLANDS. | | | THERE IS ALSO AN OPTION TO ELIMINATE PERIMETER | | | LANDSCAPE ISLANDS BY PROVIDING ALTERNATIVE AREAS FOR | | | TREE CANOPY. | | | THE SITE AND LANDSCAPE PLAN HAVE BEEN RECONFIGURED AND | | | THE 18 SPACES IS NOT APPLICABLE. | | | | | | | | | 3. NO LONGER APPLICABLE. A WAIVER FOR SECTION 94-243, | | | TABLE VII-3 COMMERCIAL DISTRICTS REGULATIONS REGARDING | | | OPEN SPACE REQUIREMENTS WOULD HAVE TO BE INCLUDED IF | | | 40% OPEN SPACE MINIMUM ON INDIVIDUAL LOTS IS NOT MET AS | | | THEY ARE DEVELOPED, AS THE MAXIMUM LOT COVERAGE AREA IS | | | 60%. OPEN SPACE BY CODE DEFINITION INCLUDES ALL AREAS | | | THAT ARE UNENCLOSED. THE MINIMUM LANDSCAPING IS 15%, | | | AND EACH LOT SHOULD BE ABLE TO MEET THIS REQUIREMENT. | | | | | | 4. SATISFIED. PROVIDE THE LANDSCAPE PLAN SHOWING | | | EXISTING AND PROPOSED LANDSCAPE FOR THE LINEAR PARK | | | AREA. THE LANDSCAPE IMPROVEMENTS ARE TO BE UPGRADES FOR | | | THE EXISTING LANDSCAPE TO JUSTIFY REDUCTIONS IN | | | LANDSCAPE IN OTHER AREAS, SO THIS NEEDS TO BE | | | QUANTIFIED. THE ACTUAL AREA IS PROPOSED TO BE REDUCED | | | BY THE ADDITION OF PARKING. | | | | | | THE DESIGN PROVIDES LITTLE AREA FOR ACTUAL USE BY | | | PEOPLE AND THE BAHIA SOD IN THE DRAINAGE AREA DOES NOT | | | OFFER ANYTHING DIFFERENT FROM THE STANDARD DESIGN. | | | STAFF SUGGESTS ENHANCED PLANTINGS TO MEET THE INTENTION | | | OF THE BIOSWALE PROVIDING VISUAL INTEREST AND HABITAT | | | CREATION WITH WALKWAYS TO ALLOW ACCESS AND VIEWING OF | | | THE ENHANCED AREA. PROVIDE AN ANALYSIS OF THE | | | COMPARISON FOR TREE CANOPY CURRENTLY EXISTING AND THE | | | PROPOSED TREE CANOPY COVERAGE. | | | THE LANDSCAPING IN THE ADJACENT RIGHT OF WAY MUST BE | | | SHOWN ON THE LANDSCAPE PLAN AND ENHANCED TO PROVIDE A | | | CONTINUOUS DESIGN FOR THE AREA. SECTION 94-452 ROADWAY | | | BEAUTIFICATION APPLIES IN THIS CASE TO THE PD SO THE | | | LANDSCAPE SHOULD BE DESIGNED, INSTALLED AND MAINTAINED | | | BY THE PROPERTY OWNER AS PART OF THE ENHANCED AREA. | | | | | | | | | 5. SATISFIED. SECTION 94-443 (C)(3)A. REQUIRES A | | | TERMINAL LANDSCAPE ISLAND AND REQUIRED TREE FOR EACH | | | ROW OF PARKING. (3)B. REQUIRES AN INTERIOR LANDSCAPE | | | ISLAND WITH A REQUIRED TREE SO THERE ARE NO MORE THAN | | | 10 SPACES IN A ROW. ALL THESE LANDSCAPE AREAS MUST MEET | | | THE MINIMUM WIDTH OF 8 FEET OF LANDSCAPE AREA AND BE | | | THE FULL LENGTH OF THE ADJACENT SPACE. (3) C. REQUIRES | | | DIVIDER MEDIANS WHERE THERE ARE MORE THAN 3 CONSECUTIVE | | | ROWS OF PARKING. ALL RECONSTRUCTED AREAS OF PARKING | | | MUST MEET THESE REQUIREMENTS, AND THE APPROVED PLAN | | | FOLLOWED FOR UNALTERED AREAS. | | | ALL AREAS OF PARKING ARE BEING RECONSTRUCTED SO PARKING | | | LOT LANDSCAPING REQUIREMENTS APPLY TO ALL AREAS. THE | | | DIVIDER MEDIANS MUST BE PROVIDED IF MORE THAN 3 | | | CONSECUTIVE ROWS OF PARKING. IF CHOOSING TO USE | | | 94-443(C)(6) B., THE INTERIOR ISLAND MUST BE SPLIT AND | | | ALTERNATED. NO ADDITIONAL TREE CANOPY HAS BEEN | | | PROVIDED. | | | THERE IS ONE LANDSCAPE ISLAND IN THE PARKING AREA SOUTH | | | OF BRANDSMART BUILDING THAT DOES NOT HAVE 2 TREES FOR | | | THE 2 ROWS OF PARKING. | | | PROVIDE DIMENSIONS FOR ALL LANDSCAPE ISLANDS AS THERE | | | APPEAR TO BE ONES IN THE EASTERN PARKING AREA THAT DO | | | NOT MEET THE MINIMUM WIDTH FOR THE FULL LENGTH OF THE | | | PARKING SPACE. NORTH EAST 4 L SHAPED LANDSCAPE ISLANDS. | | | 6/3/21 | | | | | | 6. SATISFIED. SECTION 94-443(C)(3) REQUIRES THAT A | | | MINIMUM OF 75 PERCENT OF ALL TREES THAT ARE REQUIRED TO | | | BE PLANTED WITHIN THE INTERIOR OF AN OFF STREET PARKING | | | AREA SHALL BE CATEGORY 1 SHADE TREES. SHOW THE | | | PERCENTAGE OF CATEGORY 1 TREES PROVIDED FOR THE | | | REQUIRED LANDSCAPE AREAS AS REQUIRED BY SECTION | | | 94-443(C)(3) FOR DIVIDER ISLANDS, TERMINAL, AND | | | INTERIOR ISLANDS. | | | PROVIDE A LISTING OF THE TREES PROVIDED IN THE INTERIOR | | | PARKING ISLANDS BY SPECIES AND COUNT AND SHOW | | | PERCENTAGE CALCULATED. | | | | | | 7. SATISFIED. PROVIDE A PLAN SHOWING THE PARKING | | | LANDSCAPE AREAS COUNTED TOWARD COMPLIANCE WITH SECTION | | | 94-443(C)(3) AND (4) AND PROVIDE CALCULATIONS. PROVIDE | | | THE TOTAL REQUIRED AND PROVIDED AS ONE TOTAL FOR BOTH | | | SECTIONS. A SEPARATE EXHIBIT MUST BE PROVIDED TO | | | DEMONSTRATE THE AREAS COUNTED. | | | THERE SHOULD BE 3 AREAS SHOWN WITH DIFFERENT SHADING OR | | | GRAPHIC. PARKING SPACES, OTHER VEHICULAR USE AREAS AND | | | INTERIOR LANDSCAPE AREAS NEED TO BE IDENTIFIED AND | | | QUANTIFIED. SECTION 94-443 (C)FIGURE XIV-1 SHOULD BE | | | USED TO DISCERN INTERIOR LANDSCAPE AREAS. THERE ARE | | | ALSO SOME AREAS SHOWN ACROSS PARCEL LINES ON THE SHEETS | | | L-211 AND L-212. | | | | | | | | | 8. PROVIDE THE FOLLOWING CORRECTIONS TO TREE | | | DISPOSITION CHART SHEET L-101: | | | ? SATISFIED. PROVIDE A COMPLETE TREE SURVEY THAT | | | INCLUDES ALL EXISTING TREES AND PALMS. COMPLETE ALL | | | COLUMNS FOR MISSING INFORMATION. | | | ? SATISFIED. LIST OFF SITE TREES AND PALMS AS OFF SITE. | | | THESE WOULD REQUIRE A SEPARATE PERMIT FROM THE OWNER OF | | | THAT PROPERTY FOR REMOVAL. | | | ? SATISFIED. IF CANOPY DIAMETERS ARE 20 FEET OR MORE, | | | CALCULATE THE ACTUAL SQUARE FOOTAGE AND ENTER INTO THE | | | MITIGATION DUE COLUMN IF PROPOSED FOR REMOVAL. IF UNDER | | | 20 FEET, THE SQUARE FOOTAGE IS BASED ON THE CATEGORY | | | FOR THE TREE. | | | | | | ? SATISFIED. ADD A COLUMN AND LIST THE CATEGORY 1, 2, | | | 3, OR 4 FOR EACH TREE AND PALM FROM THE CITY REFERENCE | | | LIST. | | | | | | ? SATISFIED. REMOVE ?UNIDENTIFIED PALM? AND LIST THE | | | SCIENTIFIC AND COMMON NAME, AS ALL TREES MUST BE | | | PROPERLY IDENTIFIED. | | | ? SATISFIED. CHANGE CANOPY AREA COLUMN TO CANOPY | | | MITIGATION DUE, AND LIST SQUARE FOOTAGE IF MITIGATION | | | IS DUE. | | | ? SATISFIED. PROVIDE THE TOTAL SQUARE FOOTAGE OF | | | MITIGATION DUE AND SHOW MITIGATION SQUARE FOOTAGE | | | PROVIDED FROM THE PROPOSED TREE LIST AFTER ALL | | | CORRECTIONS. | | | | | | ? SATISFIED. INCLUDE A LIST OF ALL SPECIES AND | | | QUANTITIES COUNTED TOWARD MITIGATION BASED ON THE | | | LANDSCAPE PLAN, NOT INCLUDING REPLACEMENTS FOR MISSING | | | APPROVED TREES AND PALMS. | | | | | | | | | 9. SATISFIED. SECTION 94-448 (D)(3) REQUIRES NATIVE | | | TREES IN GOOD CONDITION TO BE PRESERVED ON SITE OR | | | RELOCATED. ANSI A 300 (PART 5) STANDARDS SPECIFY | | | EXAMPLES OF SUITABILITY RATINGS OF GOOD, MODERATE, OR | | | POOR FOR RELOCATION. PROVIDE CONDITION FOR ALL EXISTING | | | TREES AND PALMS AND RELOCATION POTENTIAL FOR THE NATIVE | | | TREES AND PALMS BASED ON A CERTIFIED ARBORISTS REPORT. | | | THE FOLLOWING SABAL PALMS AND ROYAL PALMS ARE LISTED IN | | | GOOD CONDITION ON THE ARBORIST REPORT YET ARE LISTED | | | FOR REMOVAL. PROVIDE AN EXPLANATION. SABAL PALM NUMBER: | | | 43, 44, 45, 229, 230, 231, 232, 233, 234, 235, 236, | | | 237, 238, 239, 240, 242, 243, 244, 245, 246, 247, 248, | | | 249, 250, 252, 253, 254, 255, 256, 257, 258, 264 | | | ROYAL PALM NUMBER: 146, 149, 151, 175, 176, 177, 193, | | | 195, 197, 201, 202, 218,219 | | | | | | | | | 10. SATISFIED. BUFFER LENGTHS REQUIRE ONE TREE PER 30 | | | FEET OR PORTION THEREOF FOR EACH BUFFER LENGTH. PROVIDE | | | THE REQUIRED AND PROVIDED BUFFER TREES IN A CHART WITH | | | THE INDIVIDUAL BUFFER SECTIONS IDENTIFIED. | | | PROVIDE THE BUFFER SECTIONS AND THE REQUIRED AND | | | PROVIDED TREES FOR EACH SECTION FOR BOTH PARCELS. THERE | | | WILL BE FOUR SECTIONS FOR EACH PARCEL WITH THE INTERIOR | | | LOT LINES INDICATED AS NOT PROVIDED PER THE WAIVER | | | REQUEST. SECTIONS CANNOT BE COMBINED. | | | | | | NOTE WITH LABEL REFERENCING SECTION 94-443(B)2 DOES NOT | | | APPLY, AS THERE IS NO VEHICLE INGRESS OR EGRESS AT THE | | | LOCATIONS ALONG I 95. | | | EXISTING DRAINAGE EASEMENT ALONG WESTERN BUFFER MAY BE | | | ABANDONED BY THE CITY IF NOT NEEDED, SO THIS AREA NEEDS | | | TO COMPLY WITH THE BUFFER REQUIREMENTS AND BE | | | COORDINATED WITH THE ADJOINING PROPERTY AND THE CITY. | | | | | | 11. SATISFIED. PROVIDE THE FOUNDATION PLANTING | | | CALCULATION REQUIRED AND PROVIDED FOR EACH BUILDING. | | | | | | 12. SATISFIED. REQUIRED TREES PER OPEN SPACE ARE NOT | | | PROVIDED, THIS WOULD REQUIRE A WAIVER. | | | THE REQUIRED OPEN SPACE CALCULATION SHOULD BE 40 | | | PERCENT OF THE TOTAL PARCEL SQUARE FOOTAGE. CORRECT FOR | | | EACH LOT AND RECALCULATE REQUIRED TREES, FLOWERING | | | TREES AND SHRUBS. | | | | | | 13. SATISFIED. PROVIDE THE NUMBER AND PERCENTAGE OF | | | SUBSTITUTION OF PALMS FOR REQUIRED TREES. SECTION | | | 94-442(D) REQUIRES A 3:1 RATIO FOR SUBSTITUTION FOR | | | PALMS EXCEPT THE LISTED 1:1 SPECIES. | | | COULD NOT LOCATE ON PLANS. | | | | | | 14. SATISFIED. ADD A SECTION IN THE LANDSCAPE DATA | | | CHART TO COMPLY WITH SECTION 94-445 L. PLANT SPECIES. A | | | MINIMUM OF 60 PERCENT OF PLANT MATERIAL ADDED SHALL BE | | | FLORIDA NATIVE OR DROUGHT TOLERANT SPECIES SELECTED | | | FROM THE CITY LIST OR THE LIST OF SPECIES IN THE MOST | | | RECENT EDITION OF SOUTH FLORIDA WATER MANAGEMENT | | | DISTRICT WATERWISE SOUTH FLORIDA LANDSCAPES. PROVIDE | | | THE TOTAL PERCENTAGE OF NATIVE AND DROUGHT TOLERANT | | | PLANTS BASED ON FINAL PLANT LIST. | | | COULD NOT LOCATE ON PLANS. | | | | | | | | | 15. SATISFIED. SHOW THE LOCATIONS OF ALL SITE LIGHTING | | | ON THE LANDSCAPE PLAN AND REDESIGN THE LOCATIONS OF THE | | | LIGHTING ON SHORTER POLES TO RESOLVE ANY CONFLICTS WITH | | | TREES IN THE PARKING AREA LANDSCAPE ISLANDS. | | | | | | 16. SATISFIED. PROVIDE SCREENING FOR ALL GROUND MOUNTED | | | VALVES AND EQUIPMENT. | | | ALL THE LOCATIONS NEED TO BE IDENTIFIED IN SOME WAY. | | | | | | 17. SATISFIED. SHOW LOCATIONS OF FPL TRANSFORMERS ON | | | THE LANDSCAPE PLAN AND RESOLVE CONFLICTS WITH | | | LANDSCAPING. EXISTING UTILITIES CLOSE TO FUEL STATION | | | DO NOT APPEAR TO HAVE LANDSCAPE SCREEN 6/2/21 | | | ALL THE LOCATIONS NEED TO BE IDENTIFIED IN SOME WAY. | | | | | | 18. SATISFIED. ADD A COLUMN TO THE PLANT LIST FOR | | | DROUGHT TOLERANT LEVELS OF EACH SPECIES. | | | | | | ADD A COLUMN INSTEAD OF ADDING THE INFORMATION UNDER | | | THE PLANT NAME. | | | | | | 19. SATISFIED. MINIMUM TREE SIZES ARE 12 FEET HEIGHT, | | | CORRECT ON PLANT LIST. | | | | | | SILVER BUTTONWOOD TREES ARE REQUIRED AT 12 FEET HEIGHT. | | | TREES ARE PROHIBITED FROM BEING TRIMMED INTO SHAPES AND | | | MUST BE ALLOWED TO DEVELOP INTO THEIR MATURE SIZE TO | | | FULFILL THE CODE REQUIREMENTS. PROVIDE REASON FOR | | | SMALLER SIZES AND SPECIES BEING USED IN BUFFERS AND | | | LANDSCAPE ISLANDS. | | | | | | 20. SATISFIED. THE OVERALL SCALE OF THE LANDSCAPE PLANS | | | NEEDS TO BE PROVIDED AT A MINIMUM 1:20 SCALE TO MAKE IT | | | POSSIBLE FOR THE DETAIL NEEDED FOR REVIEW. THE SCALE | | | NEEDS TO BE CALLED OUT ON THE PLAN. | | | | | | 21. SATISFIED. PROPOSED SUBDIVISION LINES NEED TO BE | | | INCLUDED ON THE LANDSCAPE PLAN AND IDENTIFY ALL BUFFER | | | SECTIONS AND INDICATE BUFFER PROVIDED OR NOT. | | | | | | ADDITIONAL COMMENTS 3/18/21: | | | | | | 22. PROVIDE DETAILED WRITTEN RESPONSES TO COMMENTS SO | | | STAFF DOES NOT HAVE TO SEARCH THE PLANS FOR THE | | | CORRECTIONS. | | | 23. SATISFIED THE ROWS OF PARKING ALONG THE SOUTH | | | BUFFER AND THE GAS AREA SHOULD HAVE THE CURB SHOWN AT | | | THE 16 FOOT MARK INSTEAD OF WHEEL STOPS TO ALLOW MORE | | | PERVIOUS AREA AS THE OVERHANG. | | | | | | 24. SATISFIED CORRECT TREES #153 AND 154 ON THE TREE | | | DISPOSITION PLAN TO MATCH THE ARBORIST EVALUATION. | | | | | | 25. SATISFIED THE BUILDING UNDER THE GAS UMP CANOPY | | | MUST SHOW THE 30% FOUNDATION LANDSCAPING REQUIRED. | | | | | | 26. SATISFIED ADD A NOTE TO THE PLAN THAT ALL GROUND | | | MOUNTED EQUIPMENT WILL BE SCREENED FROM VIEW PER CODE | | | REQUIREMENTS. | | | ADDITIONAL COMMENTS 6/3/21: | | | 27. SATISFIED PLANTS IN BIO/WETLAND AREA WITH TRIANGLE | | | IN CIRCLE SYMBOL ARE NOT LISTED IN PLANT LIST. ADD TO | | | LIST. | | | 28. SATISFIED AS LISTED IN #17 SCREENING FOR UTILITIES | | | DO NOT APPEAR TO BE PRESENT BY FUEL STATION. | | | 29. SATISFIED AS LISTED IN #5 PROVIDE DIMENSIONS FOR | | | ALL LANDSCAPE ISLANDS AS THERE APPEAR TO BE ONES IN THE | | | EASTERN PARKING AREA THAT DO NOT MEET THE MINIMUM WIDTH | | | FOR THE FULL LENGTH OF THE PARKING SPACE. NORTH EAST | | | SECTION OF PARKING LOT 4 L SHAPED LANDSCAPE ISLANDS OF | | | CONCERN. DIMENSIONS SHOWN FOR WIDE PLANTING AREA BUT | | | NOT FOR THE NARROW PARTS OF CONCERN. | | | 30. SATISFIED MAINTENANCE NOTE: ON EAST SIDE OF BIO | | | SWALE COCOPLUMS SHOULD BE ALLOWED TO GROW PROVIDING 6-8 | | | FT SCREENING OF BUILDING . | | | 6/24/21 | | | | | | 31. SATISFIED THROUGHOUT THE PLAN IT HAD BEEN NOTED | | | THAT THERE ARE MANY LOCATIONS WHERE TREES ARE PLANTED | | | ON TOP OF OR IN CLOSE PROXIMITY TO UTILITY LINES. THIS | | | IS NOT PERMITTED | | | 32. SATISFIED LANDSCAPE DIVIDER MEDIANS ARE REQUIRED IN | | | PARKING LOT EAST OF THE FUEL STATION. THIS WAS | | | MENTIONED BY RAY CRANCI AND STILL NEEDS TO BE | | | ADDRESSED. UPDATE OF PARKING TABLE MAY BE REQUIRED. | | | 33. SATISFIED THE REQUIRED AND PROVIDED TREE COUNTS ON | | | THE WPB LANDSCAPE LEGEND CONTAIN ERRORS. THE CITY | | | REQUIRES THAT ANY PARTIAL TREE IS ROUNDED UP. THIS | | | REQUIRED TREES ON THE EAST, WEST AND EXECUTIVE CENTER | | | DRIVE FRONTAGES EACH REQUIRE ONE ADDITIONAL TREE. STAFF | | | HAS COUNTED THE TREES ALONG EACH OF THESE BUFFERS AND | | | THERE ARE AN ADEQUATE NUMBER OF TREES (NOT TRESS AS | | | MISSPELLED ON THE TABLE) PROVIDED, AND ON AT LEAST TWO | | | OF THE BUFFERS THE NUMBER PROVIDED IS UNDER COUNTED | | | COMPARED WITH WHAT IS PROVIDED. | | | 34. SATISFIED THE PARKING LOT TERMINAL ISLANDS DO NOT | | | HAVE REQUIRED TREES. MARKED UP PLANS WILL BE PROVIDED . | | | 35. SATISFIED THE EXISTING STORMWATER PIPE FROM BEST | | | BUY TO EXECUTIVE CENTER DRIVE IS NOT SHOWN ON SHEET | | | L-200 BUT NOT ON ENLARGED SHEET L-201. THE PROPOSED | | | REPLACEMENT 12-FOOT WIDE STORMWATER EASEMENT, CENTERED | | | ON THE STORMWATER PIPE, IS NOT SHOWN ON EITHER SHEET. | | | THESE MUST BE SHOWN ON BOTH SHEETS SO THAT PLANNING CAN | | | VERIFY THAT THERE ARE NO TREES PLACED WITHIN THE | | | STORMWATER EASEMENT AND THAT TREES IN PROXIMITY TO THE | | | EASEMENT HAVE THE PROPER ROOT BARRIER. A WAIVER IS | | | REQUIRED FOR THE TREES THAT WILL NOT BE INSTALLED AND | | | WITHOUT THE EASEMENT ACCURATELY SHOWN ON THE PLAN, | | | STAFF CANNOT ENUMERATE THE SPECIFIC WAIVER REQUIRED. | | | | | | | | | | | | | | | | | | CONDITIONS OF APPROVAL | | | | | | 1. PRIOR TO THE REMOVAL OR RELOCATION OF ANY TREES ON | | | THE PROPERTY, A TREE ALTERATION PERMIT SHALL BE | | | SUBMITTED, REVIEWED AND APPROVED BY THE DEVELOPMENT | | | SERVICES DEPARTMENT, PLANNING DIVISION. | | | 2. THE APPLICANT, SUCCESSORS AND ASSIGNS SHALL BE | | | RESPONSIBLE FOR THE PERMITTING AND INSTALLATION OF THE | | | STREET TREES AND RIGHT OF WAY LANDSCAPING AND | | | IRRIGATION APPROVED WITH THIS PETITION. | | | 3. THE APPLICANT, SUCCESSORS AND ASSIGNS SHALL BE | | | RESPONSIBLE FOR THE MAINTENANCE OF THE ROAD RIGHT OF | | | WAY LANDSCAPING AND IRRIGATION. THIS WILL BE THROUGH A | | | SEPARATE MAINTENANCE AGREEMENT WITH THE CITY. | | | 6/24/2021 | | | 4. UPDATE WEST SIDE LANDSCAPE BUFFER TREE COUNT TO | | | REFLECT DRAINAGE EASEMENT. 25 TREES LISTED WPB | | | LANDSCAPE LEGEND WEST BUFFER DOES NOT MATCH PLAN . | | | SHEET L-210 | | | 7/16/2021 | | | 5. PRIOR TO LANDSCAPE CO UPDATE PLAN TO SHOW ROOT | | | BARRIER LOCATION FOR EFFECTED TREES. | | | |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
4 |
Status |
F |
Date |
06-25-2021 |
|
|
Cont ID |
|
| Sent By |
aburnett |
Date |
06-24-2021 |
Time |
09:07 |
Rev Time |
0.00 |
| Received By |
aburnett |
Date |
06-24-2021 |
Time |
09:06 |
Sent To |
|
|
| Notes |
| 2021-06-24 09:07:56 | FROM: ANDREW BURNETT, LANDSCAPE PLANNER 561-822-1462 | | | PROJECT: BJ?S AT BRANDSMART CPD Z20070016 | | | JUNE 24, 2021 | | | I HAVE REVIEWED THE ABOVE REFERENCED PETITION, AND | | | PROVIDE THE FOLLOWING COMMENTS: | | | | | | 1. SATISFIED. DESIGN GUIDELINES: | | | ? THE EXCEPTION TO THE LANDSCAPE BUFFER FOR WATER | | | BODIES OR I-95 IS NOT SUPPORTED BY STAFF. THE PERIMETER | | | OF THE BRANDSMART PD MUST HAVE THE REQUIRED BUFFER AS | | | STATED. | | | ? BUFFERS MAY BE ADJUSTED TO AVOID UTILITY EASEMENT | | | OVERLAP THAT WOULD PREVENT THE REQUIRED LANDSCAPING | | | FROM BEING ALLOWED. THIS IS REINFORCED BY THE EASEMENT | | | REQUIREMENT NOT BEING ALLOWED TO COUNT TOWARD BUFFER | | | REQUIREMENT. | | | ? ALL LANDSCAPE BUFFERS MUST MEET ALL THE REQUIREMENTS | | | OF ARTICLE XIV ?LANDSCAPING, LAND CLEARING, TREE | | | PROTECTION AND ARTIFICIAL TURF?. | | | ? ALL BUILDINGS MODIFIED OR ADDED MUST MEET THE 30 | | | PERCENT LINEAR FOOTAGE REQUIREMENT FOR FOUNDATION | | | LANDSCAPING. | | | THE DESIGN GUIDELINES ARE NO LONGER NEEDED FOR | | | LANDSCAPE ITEMS. NOW THAT THE SUBDIVISION REQUEST ONLY | | | CREATES 2 LOTS, CODE REQUIREMENTS CAN BE MET, OR A | | | WAIVER REQUESTED. | | | | | | 2. WAIVER REQUESTS. | | | ? SATISFIED. #1 SHOULD READ: PROPOSED -WAIVE THE FIVE | | | FOOT BUFFER REQUIREMENT FOR INTERIOR LOT LINES. | | | ? SATISFIED. #5 UP TO18 PARKING SPACES IN A ROW FOR | | | NEW PARKING AREAS WOULD HAVE TO PROVIDE TREE CANOPY IN | | | SOME OTHER WAY TO MEET THE INTENT OF 94-443(C). OPTIONS | | | ARE CURRENTLY AVAILABLE IN THE CODE TO ALLOW UP TO 12 | | | SPACES IN A ROW BY EXPANDING THE LANDSCAPE ISLANDS. | | | THERE IS ALSO AN OPTION TO ELIMINATE PERIMETER | | | LANDSCAPE ISLANDS BY PROVIDING ALTERNATIVE AREAS FOR | | | TREE CANOPY. | | | THE SITE AND LANDSCAPE PLAN HAVE BEEN RECONFIGURED AND | | | THE 18 SPACES IS NOT APPLICABLE. | | | | | | | | | 3. NO LONGER APPLICABLE. A WAIVER FOR SECTION 94-243, | | | TABLE VII-3 COMMERCIAL DISTRICTS REGULATIONS REGARDING | | | OPEN SPACE REQUIREMENTS WOULD HAVE TO BE INCLUDED IF | | | 40% OPEN SPACE MINIMUM ON INDIVIDUAL LOTS IS NOT MET AS | | | THEY ARE DEVELOPED, AS THE MAXIMUM LOT COVERAGE AREA IS | | | 60%. OPEN SPACE BY CODE DEFINITION INCLUDES ALL AREAS | | | THAT ARE UNENCLOSED. THE MINIMUM LANDSCAPING IS 15%, | | | AND EACH LOT SHOULD BE ABLE TO MEET THIS REQUIREMENT. | | | | | | 4. SATISFIED. PROVIDE THE LANDSCAPE PLAN SHOWING | | | EXISTING AND PROPOSED LANDSCAPE FOR THE LINEAR PARK | | | AREA. THE LANDSCAPE IMPROVEMENTS ARE TO BE UPGRADES FOR | | | THE EXISTING LANDSCAPE TO JUSTIFY REDUCTIONS IN | | | LANDSCAPE IN OTHER AREAS, SO THIS NEEDS TO BE | | | QUANTIFIED. THE ACTUAL AREA IS PROPOSED TO BE REDUCED | | | BY THE ADDITION OF PARKING. | | | | | | THE DESIGN PROVIDES LITTLE AREA FOR ACTUAL USE BY | | | PEOPLE AND THE BAHIA SOD IN THE DRAINAGE AREA DOES NOT | | | OFFER ANYTHING DIFFERENT FROM THE STANDARD DESIGN. | | | STAFF SUGGESTS ENHANCED PLANTINGS TO MEET THE INTENTION | | | OF THE BIOSWALE PROVIDING VISUAL INTEREST AND HABITAT | | | CREATION WITH WALKWAYS TO ALLOW ACCESS AND VIEWING OF | | | THE ENHANCED AREA. PROVIDE AN ANALYSIS OF THE | | | COMPARISON FOR TREE CANOPY CURRENTLY EXISTING AND THE | | | PROPOSED TREE CANOPY COVERAGE. | | | THE LANDSCAPING IN THE ADJACENT RIGHT OF WAY MUST BE | | | SHOWN ON THE LANDSCAPE PLAN AND ENHANCED TO PROVIDE A | | | CONTINUOUS DESIGN FOR THE AREA. SECTION 94-452 ROADWAY | | | BEAUTIFICATION APPLIES IN THIS CASE TO THE PD SO THE | | | LANDSCAPE SHOULD BE DESIGNED, INSTALLED AND MAINTAINED | | | BY THE PROPERTY OWNER AS PART OF THE ENHANCED AREA. | | | | | | | | | 5. PARTIALLY SATISFIED. SECTION 94-443 (C)(3)A. | | | REQUIRES A TERMINAL LANDSCAPE ISLAND AND REQUIRED TREE | | | FOR EACH ROW OF PARKING. (3)B. REQUIRES AN INTERIOR | | | LANDSCAPE ISLAND WITH A REQUIRED TREE SO THERE ARE NO | | | MORE THAN 10 SPACES IN A ROW. ALL THESE LANDSCAPE AREAS | | | MUST MEET THE MINIMUM WIDTH OF 8 FEET OF LANDSCAPE AREA | | | AND BE THE FULL LENGTH OF THE ADJACENT SPACE. (3) C. | | | REQUIRES DIVIDER MEDIANS WHERE THERE ARE MORE THAN 3 | | | CONSECUTIVE ROWS OF PARKING. ALL RECONSTRUCTED AREAS OF | | | PARKING MUST MEET THESE REQUIREMENTS, AND THE APPROVED | | | PLAN FOLLOWED FOR UNALTERED AREAS. | | | ALL AREAS OF PARKING ARE BEING RECONSTRUCTED SO PARKING | | | LOT LANDSCAPING REQUIREMENTS APPLY TO ALL AREAS. THE | | | DIVIDER MEDIANS MUST BE PROVIDED IF MORE THAN 3 | | | CONSECUTIVE ROWS OF PARKING. IF CHOOSING TO USE | | | 94-443(C)(6) B., THE INTERIOR ISLAND MUST BE SPLIT AND | | | ALTERNATED. NO ADDITIONAL TREE CANOPY HAS BEEN | | | PROVIDED. | | | THERE IS ONE LANDSCAPE ISLAND IN THE PARKING AREA SOUTH | | | OF BRANDSMART BUILDING THAT DOES NOT HAVE 2 TREES FOR | | | THE 2 ROWS OF PARKING. | | | PROVIDE DIMENSIONS FOR ALL LANDSCAPE ISLANDS AS THERE | | | APPEAR TO BE ONES IN THE EASTERN PARKING AREA THAT DO | | | NOT MEET THE MINIMUM WIDTH FOR THE FULL LENGTH OF THE | | | PARKING SPACE. NORTH EAST 4 L SHAPED LANDSCAPE ISLANDS. | | | 6/3/21 | | | | | | 6. SATISFIED. SECTION 94-443(C)(3) REQUIRES THAT A | | | MINIMUM OF 75 PERCENT OF ALL TREES THAT ARE REQUIRED TO | | | BE PLANTED WITHIN THE INTERIOR OF AN OFF STREET PARKING | | | AREA SHALL BE CATEGORY 1 SHADE TREES. SHOW THE | | | PERCENTAGE OF CATEGORY 1 TREES PROVIDED FOR THE | | | REQUIRED LANDSCAPE AREAS AS REQUIRED BY SECTION | | | 94-443(C)(3) FOR DIVIDER ISLANDS, TERMINAL, AND | | | INTERIOR ISLANDS. | | | PROVIDE A LISTING OF THE TREES PROVIDED IN THE INTERIOR | | | PARKING ISLANDS BY SPECIES AND COUNT AND SHOW | | | PERCENTAGE CALCULATED. | | | | | | 7. SATISFIED. PROVIDE A PLAN SHOWING THE PARKING | | | LANDSCAPE AREAS COUNTED TOWARD COMPLIANCE WITH SECTION | | | 94-443(C)(3) AND (4) AND PROVIDE CALCULATIONS. PROVIDE | | | THE TOTAL REQUIRED AND PROVIDED AS ONE TOTAL FOR BOTH | | | SECTIONS. A SEPARATE EXHIBIT MUST BE PROVIDED TO | | | DEMONSTRATE THE AREAS COUNTED. | | | THERE SHOULD BE 3 AREAS SHOWN WITH DIFFERENT SHADING OR | | | GRAPHIC. PARKING SPACES, OTHER VEHICULAR USE AREAS AND | | | INTERIOR LANDSCAPE AREAS NEED TO BE IDENTIFIED AND | | | QUANTIFIED. SECTION 94-443 (C)FIGURE XIV-1 SHOULD BE | | | USED TO DISCERN INTERIOR LANDSCAPE AREAS. THERE ARE | | | ALSO SOME AREAS SHOWN ACROSS PARCEL LINES ON THE SHEETS | | | L-211 AND L-212. | | | | | | | | | 8. PROVIDE THE FOLLOWING CORRECTIONS TO TREE | | | DISPOSITION CHART SHEET L-101: | | | ? SATISFIED. PROVIDE A COMPLETE TREE SURVEY THAT | | | INCLUDES ALL EXISTING TREES AND PALMS. COMPLETE ALL | | | COLUMNS FOR MISSING INFORMATION. | | | ? SATISFIED. LIST OFF SITE TREES AND PALMS AS OFF SITE. | | | THESE WOULD REQUIRE A SEPARATE PERMIT FROM THE OWNER OF | | | THAT PROPERTY FOR REMOVAL. | | | ? SATISFIED. IF CANOPY DIAMETERS ARE 20 FEET OR MORE, | | | CALCULATE THE ACTUAL SQUARE FOOTAGE AND ENTER INTO THE | | | MITIGATION DUE COLUMN IF PROPOSED FOR REMOVAL. IF UNDER | | | 20 FEET, THE SQUARE FOOTAGE IS BASED ON THE CATEGORY | | | FOR THE TREE. | | | | | | ? SATISFIED. ADD A COLUMN AND LIST THE CATEGORY 1, 2, | | | 3, OR 4 FOR EACH TREE AND PALM FROM THE CITY REFERENCE | | | LIST. | | | | | | ? SATISFIED. REMOVE ?UNIDENTIFIED PALM? AND LIST THE | | | SCIENTIFIC AND COMMON NAME, AS ALL TREES MUST BE | | | PROPERLY IDENTIFIED. | | | ? SATISFIED. CHANGE CANOPY AREA COLUMN TO CANOPY | | | MITIGATION DUE, AND LIST SQUARE FOOTAGE IF MITIGATION | | | IS DUE. | | | ? SATISFIED. PROVIDE THE TOTAL SQUARE FOOTAGE OF | | | MITIGATION DUE AND SHOW MITIGATION SQUARE FOOTAGE | | | PROVIDED FROM THE PROPOSED TREE LIST AFTER ALL | | | CORRECTIONS. | | | | | | ? SATISFIED. INCLUDE A LIST OF ALL SPECIES AND | | | QUANTITIES COUNTED TOWARD MITIGATION BASED ON THE | | | LANDSCAPE PLAN, NOT INCLUDING REPLACEMENTS FOR MISSING | | | APPROVED TREES AND PALMS. | | | | | | | | | 9. SATISFIED. SECTION 94-448 (D)(3) REQUIRES NATIVE | | | TREES IN GOOD CONDITION TO BE PRESERVED ON SITE OR | | | RELOCATED. ANSI A 300 (PART 5) STANDARDS SPECIFY | | | EXAMPLES OF SUITABILITY RATINGS OF GOOD, MODERATE, OR | | | POOR FOR RELOCATION. PROVIDE CONDITION FOR ALL EXISTING | | | TREES AND PALMS AND RELOCATION POTENTIAL FOR THE NATIVE | | | TREES AND PALMS BASED ON A CERTIFIED ARBORISTS REPORT. | | | THE FOLLOWING SABAL PALMS AND ROYAL PALMS ARE LISTED IN | | | GOOD CONDITION ON THE ARBORIST REPORT YET ARE LISTED | | | FOR REMOVAL. PROVIDE AN EXPLANATION. SABAL PALM NUMBER: | | | 43, 44, 45, 229, 230, 231, 232, 233, 234, 235, 236, | | | 237, 238, 239, 240, 242, 243, 244, 245, 246, 247, 248, | | | 249, 250, 252, 253, 254, 255, 256, 257, 258, 264 | | | ROYAL PALM NUMBER: 146, 149, 151, 175, 176, 177, 193, | | | 195, 197, 201, 202, 218,219 | | | | | | | | | 10. SATISFIED. BUFFER LENGTHS REQUIRE ONE TREE PER 30 | | | FEET OR PORTION THEREOF FOR EACH BUFFER LENGTH. PROVIDE | | | THE REQUIRED AND PROVIDED BUFFER TREES IN A CHART WITH | | | THE INDIVIDUAL BUFFER SECTIONS IDENTIFIED. | | | PROVIDE THE BUFFER SECTIONS AND THE REQUIRED AND | | | PROVIDED TREES FOR EACH SECTION FOR BOTH PARCELS. THERE | | | WILL BE FOUR SECTIONS FOR EACH PARCEL WITH THE INTERIOR | | | LOT LINES INDICATED AS NOT PROVIDED PER THE WAIVER | | | REQUEST. SECTIONS CANNOT BE COMBINED. | | | | | | NOTE WITH LABEL REFERENCING SECTION 94-443(B)2 DOES NOT | | | APPLY, AS THERE IS NO VEHICLE INGRESS OR EGRESS AT THE | | | LOCATIONS ALONG I 95. | | | EXISTING DRAINAGE EASEMENT ALONG WESTERN BUFFER MAY BE | | | ABANDONED BY THE CITY IF NOT NEEDED, SO THIS AREA NEEDS | | | TO COMPLY WITH THE BUFFER REQUIREMENTS AND BE | | | COORDINATED WITH THE ADJOINING PROPERTY AND THE CITY. | | | | | | 11. SATISFIED. PROVIDE THE FOUNDATION PLANTING | | | CALCULATION REQUIRED AND PROVIDED FOR EACH BUILDING. | | | | | | 12. SATISFIED. REQUIRED TREES PER OPEN SPACE ARE NOT | | | PROVIDED, THIS WOULD REQUIRE A WAIVER. | | | THE REQUIRED OPEN SPACE CALCULATION SHOULD BE 40 | | | PERCENT OF THE TOTAL PARCEL SQUARE FOOTAGE. CORRECT FOR | | | EACH LOT AND RECALCULATE REQUIRED TREES, FLOWERING | | | TREES AND SHRUBS. | | | | | | 13. SATISFIED. PROVIDE THE NUMBER AND PERCENTAGE OF | | | SUBSTITUTION OF PALMS FOR REQUIRED TREES. SECTION | | | 94-442(D) REQUIRES A 3:1 RATIO FOR SUBSTITUTION FOR | | | PALMS EXCEPT THE LISTED 1:1 SPECIES. | | | COULD NOT LOCATE ON PLANS. | | | | | | 14. SATISFIED. ADD A SECTION IN THE LANDSCAPE DATA | | | CHART TO COMPLY WITH SECTION 94-445 L. PLANT SPECIES. A | | | MINIMUM OF 60 PERCENT OF PLANT MATERIAL ADDED SHALL BE | | | FLORIDA NATIVE OR DROUGHT TOLERANT SPECIES SELECTED | | | FROM THE CITY LIST OR THE LIST OF SPECIES IN THE MOST | | | RECENT EDITION OF SOUTH FLORIDA WATER MANAGEMENT | | | DISTRICT WATERWISE SOUTH FLORIDA LANDSCAPES. PROVIDE | | | THE TOTAL PERCENTAGE OF NATIVE AND DROUGHT TOLERANT | | | PLANTS BASED ON FINAL PLANT LIST. | | | COULD NOT LOCATE ON PLANS. | | | | | | | | | 15. SATISFIED. SHOW THE LOCATIONS OF ALL SITE LIGHTING | | | ON THE LANDSCAPE PLAN AND REDESIGN THE LOCATIONS OF THE | | | LIGHTING ON SHORTER POLES TO RESOLVE ANY CONFLICTS WITH | | | TREES IN THE PARKING AREA LANDSCAPE ISLANDS. | | | | | | 16. SATISFIED. PROVIDE SCREENING FOR ALL GROUND MOUNTED | | | VALVES AND EQUIPMENT. | | | ALL THE LOCATIONS NEED TO BE IDENTIFIED IN SOME WAY. | | | | | | 17. SATISFIED. SHOW LOCATIONS OF FPL TRANSFORMERS ON | | | THE LANDSCAPE PLAN AND RESOLVE CONFLICTS WITH | | | LANDSCAPING. EXISTING UTILITIES CLOSE TO FUEL STATION | | | DO NOT APPEAR TO HAVE LANDSCAPE SCREEN 6/2/21 | | | ALL THE LOCATIONS NEED TO BE IDENTIFIED IN SOME WAY. | | | | | | 18. SATISFIED. ADD A COLUMN TO THE PLANT LIST FOR | | | DROUGHT TOLERANT LEVELS OF EACH SPECIES. | | | | | | ADD A COLUMN INSTEAD OF ADDING THE INFORMATION UNDER | | | THE PLANT NAME. | | | | | | 19. SATISFIED. MINIMUM TREE SIZES ARE 12 FEET HEIGHT, | | | CORRECT ON PLANT LIST. | | | | | | SILVER BUTTONWOOD TREES ARE REQUIRED AT 12 FEET HEIGHT. | | | TREES ARE PROHIBITED FROM BEING TRIMMED INTO SHAPES AND | | | MUST BE ALLOWED TO DEVELOP INTO THEIR MATURE SIZE TO | | | FULFILL THE CODE REQUIREMENTS. PROVIDE REASON FOR | | | SMALLER SIZES AND SPECIES BEING USED IN BUFFERS AND | | | LANDSCAPE ISLANDS. | | | | | | 20. SATISFIED. THE OVERALL SCALE OF THE LANDSCAPE PLANS | | | NEEDS TO BE PROVIDED AT A MINIMUM 1:20 SCALE TO MAKE IT | | | POSSIBLE FOR THE DETAIL NEEDED FOR REVIEW. THE SCALE | | | NEEDS TO BE CALLED OUT ON THE PLAN. | | | | | | 21. SATISFIED. PROPOSED SUBDIVISION LINES NEED TO BE | | | INCLUDED ON THE LANDSCAPE PLAN AND IDENTIFY ALL BUFFER | | | SECTIONS AND INDICATE BUFFER PROVIDED OR NOT. | | | | | | ADDITIONAL COMMENTS 3/18/21: | | | | | | 22. PROVIDE DETAILED WRITTEN RESPONSES TO COMMENTS SO | | | STAFF DOES NOT HAVE TO SEARCH THE PLANS FOR THE | | | CORRECTIONS. | | | 23. SATISFIED THE ROWS OF PARKING ALONG THE SOUTH | | | BUFFER AND THE GAS AREA SHOULD HAVE THE CURB SHOWN AT | | | THE 16 FOOT MARK INSTEAD OF WHEEL STOPS TO ALLOW MORE | | | PERVIOUS AREA AS THE OVERHANG. | | | | | | 24. SATISFIED CORRECT TREES #153 AND 154 ON THE TREE | | | DISPOSITION PLAN TO MATCH THE ARBORIST EVALUATION. | | | | | | 25. SATISFIED THE BUILDING UNDER THE GAS UMP CANOPY | | | MUST SHOW THE 30% FOUNDATION LANDSCAPING REQUIRED. | | | | | | 26. SATISFIED ADD A NOTE TO THE PLAN THAT ALL GROUND | | | MOUNTED EQUIPMENT WILL BE SCREENED FROM VIEW PER CODE | | | REQUIREMENTS. | | | ADDITIONAL COMMENTS 6/3/21: | | | 27. SATISFIED PLANTS IN BIO/WETLAND AREA WITH TRIANGLE | | | IN CIRCLE SYMBOL ARE NOT LISTED IN PLANT LIST. ADD TO | | | LIST. | | | 28. SATISFIED AS LISTED IN #17 SCREENING FOR UTILITIES | | | DO NOT APPEAR TO BE PRESENT BY FUEL STATION. | | | 29. SATISFIED AS LISTED IN #5 PROVIDE DIMENSIONS FOR | | | ALL LANDSCAPE ISLANDS AS THERE APPEAR TO BE ONES IN THE | | | EASTERN PARKING AREA THAT DO NOT MEET THE MINIMUM WIDTH | | | FOR THE FULL LENGTH OF THE PARKING SPACE. NORTH EAST | | | SECTION OF PARKING LOT 4 L SHAPED LANDSCAPE ISLANDS OF | | | CONCERN. DIMENSIONS SHOWN FOR WIDE PLANTING AREA BUT | | | NOT FOR THE NARROW PARTS OF CONCERN. | | | 30. SATISFIED MAINTENANCE NOTE: ON EAST SIDE OF BIO | | | SWALE COCOPLUMS SHOULD BE ALLOWED TO GROW PROVIDING 6-8 | | | FT SCREENING OF BUILDING . | | | 6/24/21 | | | | | | 31. THROUGHOUT THE PLAN IT HAD BEEN NOTED THAT THERE | | | ARE MANY LOCATIONS WHERE TREES ARE PLANTED ONTOP OF OR | | | IN CLOSE PROXIMITY TO UTILITE LINES. THIS IS NOT | | | PERMITTED | | | 32. LANDSCAPE DEVIDER MEDIANS ARE REQUIRED IN PARKING | | | LOT EAST OF THE FUEL STATION. THIS WAS MENTIONED BY RAY | | | CRANCI AND STILL NEEDS TO BE ADDRESSED. UPDATE OF | | | PARKING TABLE MAY BE REQUIRED. | | | 33.THE REQUIRED AND PROVIDED TREE COUNTS ON THE WPB | | | LANDSCAPE LEGEND CONTAIN ERRORS. THE CITY REQUIRES THAT | | | ANY PARTIAL TREE IS ROUNDED UP. THIS REQUIRED TREES ON | | | THE EAST, WEST AND EXECUTIVE CENTER DRIVE FRONTAGES | | | EACH REQUIRE ONE ADDITIONAL TREE. STAFF HAS COUNTED THE | | | TREES ALONG EACH OF THESE BUFFERS AND THERE ARE AN | | | ADEQUATE NUMBER OF TREES (NOT TRESS AS MISSPELLED ON | | | THE TABLE) PROVIDED, AND ON AT LEAST TWO OF THE BUFFERS | | | THE NUMBER PROVIDED IS UNDER COUNTED COMPARED WITH WHAT | | | IS PROVIDED. | | | 34. THE PARKING LOT TURMINAL ISLANDS DO NOT HAVE | | | REQUIRED TREES. MARKED UP PLANS WILL BE PROVIDED . | | | 35.THE EXISTING STORMWATER PIPE FROM BEST BUY TO | | | EXECUTIVE CENTER DRIVE IS NOT SHOWN ON SHEET L-200 BUT | | | NOT ON ENLARGED SHEET L-201. THE PROPOSED REPLACEMENT | | | 12-FOOT WIDE STORMWATER EASEMENT, CENTERED ON THE | | | STORMWATER PIPE, IS NOT SHOWN ON EITHER SHEET. THESE | | | MUST BE SHOWN ON BOTH SHEETS SO THAT PLANNING CAN | | | VERIFY THAT THERE ARE NO TREES PLACED WITHIN THE | | | STORMWATER EASEMENT AND THAT TREES IN PROXIMITY TO THE | | | EASEMENT HAVE THE PROPER ROOT BARRIER. A WAIVER IS | | | REQUIRED FOR THE TREES THAT WILL NOT BE INSTALLED AND | | | WITHOUT THE EASEMENT ACCURATELY SHOWN ON THE PLAN, | | | STAFF CANNOT ENUMERATE THE SPECIFIC WAIVER REQUIRED. | | | | | | | | | | | | | | | | | | CONDITIONS OF APPROVAL | | | 1. PRIOR TO THE REMOVAL OR RELOCATION OF ANY TREES ON | | | THE PROPERTY, A TREE ALTERATION PERMIT SHALL BE | | | SUBMITTED, REVIEWED AND APPROVED BY THE DEVELOPMENT | | | SERVICES DEPARTMENT, PLANNING DIVISION. | | | 2. THE APPLICANT, SUCCESSORS AND ASSIGNS SHALL BE | | | RESPONSIBLE FOR THE PERMITTING AND INSTALLATION OF THE | | | STREET TREES AND RIGHT OF WAY LANDSCAPING AND | | | IRRIGATION APPROVED WITH THIS PETITION. | | | 3. THE APPLICANT, SUCCESSORS AND ASSIGNS SHALL BE | | | RESPONSIBLE FOR THE MAINTENANCE OF THE ROAD RIGHT OF | | | WAY LANDSCAPING AND IRRIGATION. THIS WILL BE THROUGH A | | | SEPARATE MAINTENANCE AGREEMENT WITH THE CITY. | | | 6/24/2021 | | | 4. UPDATE WEST SIDE LANDSCAPE BUFFER TREE COUNT TO | | | REFLECT DRAINAGE EASEMENT. 25 TREES LISTED WPB | | | LANDSCAPE LEGEND WEST BUFFER DOES NOT MATCH PLAN . | | | SHEET L-210 | | | |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
3 |
Status |
F |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
06-03-2021 |
Time |
|
Rev Time |
0.00 |
| Received By |
|
Date |
06-03-2021 |
Time |
|
Sent To |
|
|
| Notes |
| 2021-06-03 13:23:17 | FROM: ANDREW BURNETT, LANDSCAPE PLANNER 561-822-1562 | | | PROJECT: BJ?S AT BRANDSMART CPD Z20070016 | | | JUNE 2, 2021 | | | I HAVE REVIEWED THE ABOVE REFERENCED PETITION, AND | | | PROVIDE THE FOLLOWING COMMENTS: | | | | | | 1. SATISFIED. DESIGN GUIDELINES: | | | ? THE EXCEPTION TO THE LANDSCAPE BUFFER FOR WATER | | | BODIES OR I-95 IS NOT SUPPORTED BY STAFF. THE PERIMETER | | | OF THE BRANDSMART PD MUST HAVE THE REQUIRED BUFFER AS | | | STATED. | | | ? BUFFERS MAY BE ADJUSTED TO AVOID UTILITY EASEMENT | | | OVERLAP THAT WOULD PREVENT THE REQUIRED LANDSCAPING | | | FROM BEING ALLOWED. THIS IS REINFORCED BY THE EASEMENT | | | REQUIREMENT NOT BEING ALLOWED TO COUNT TOWARD BUFFER | | | REQUIREMENT. | | | ? ALL LANDSCAPE BUFFERS MUST MEET ALL THE REQUIREMENTS | | | OF ARTICLE XIV ?LANDSCAPING, LAND CLEARING, TREE | | | PROTECTION AND ARTIFICIAL TURF?. | | | ? ALL BUILDINGS MODIFIED OR ADDED MUST MEET THE 30 | | | PERCENT LINEAR FOOTAGE REQUIREMENT FOR FOUNDATION | | | LANDSCAPING. | | | THE DESIGN GUIDELINES ARE NO LONGER NEEDED FOR | | | LANDSCAPE ITEMS. NOW THAT THE SUBDIVISION REQUEST ONLY | | | CREATES 2 LOTS, CODE REQUIREMENTS CAN BE MET, OR A | | | WAIVER REQUESTED. | | | | | | 2. WAIVER REQUESTS. | | | ? SATISFIED. #1 SHOULD READ: PROPOSED -WAIVE THE FIVE | | | FOOT BUFFER REQUIREMENT FOR INTERIOR LOT LINES. | | | ? SATISFIED. #5 UP TO18 PARKING SPACES IN A ROW FOR | | | NEW PARKING AREAS WOULD HAVE TO PROVIDE TREE CANOPY IN | | | SOME OTHER WAY TO MEET THE INTENT OF 94-443(C). OPTIONS | | | ARE CURRENTLY AVAILABLE IN THE CODE TO ALLOW UP TO 12 | | | SPACES IN A ROW BY EXPANDING THE LANDSCAPE ISLANDS. | | | THERE IS ALSO AN OPTION TO ELIMINATE PERIMETER | | | LANDSCAPE ISLANDS BY PROVIDING ALTERNATIVE AREAS FOR | | | TREE CANOPY. | | | THE SITE AND LANDSCAPE PLAN HAVE BEEN RECONFIGURED AND | | | THE 18 SPACES IS NOT APPLICABLE. | | | | | | | | | 3. NO LONGER APPLICABLE. A WAIVER FOR SECTION 94-243, | | | TABLE VII-3 COMMERCIAL DISTRICTS REGULATIONS REGARDING | | | OPEN SPACE REQUIREMENTS WOULD HAVE TO BE INCLUDED IF | | | 40% OPEN SPACE MINIMUM ON INDIVIDUAL LOTS IS NOT MET AS | | | THEY ARE DEVELOPED, AS THE MAXIMUM LOT COVERAGE AREA IS | | | 60%. OPEN SPACE BY CODE DEFINITION INCLUDES ALL AREAS | | | THAT ARE UNENCLOSED. THE MINIMUM LANDSCAPING IS 15%, | | | AND EACH LOT SHOULD BE ABLE TO MEET THIS REQUIREMENT. | | | | | | 4. SATISFIED. PROVIDE THE LANDSCAPE PLAN SHOWING | | | EXISTING AND PROPOSED LANDSCAPE FOR THE LINEAR PARK | | | AREA. THE LANDSCAPE IMPROVEMENTS ARE TO BE UPGRADES FOR | | | THE EXISTING LANDSCAPE TO JUSTIFY REDUCTIONS IN | | | LANDSCAPE IN OTHER AREAS, SO THIS NEEDS TO BE | | | QUANTIFIED. THE ACTUAL AREA IS PROPOSED TO BE REDUCED | | | BY THE ADDITION OF PARKING. | | | | | | THE DESIGN PROVIDES LITTLE AREA FOR ACTUAL USE BY | | | PEOPLE AND THE BAHIA SOD IN THE DRAINAGE AREA DOES NOT | | | OFFER ANYTHING DIFFERENT FROM THE STANDARD DESIGN. | | | STAFF SUGGESTS ENHANCED PLANTINGS TO MEET THE INTENTION | | | OF THE BIOSWALE PROVIDING VISUAL INTEREST AND HABITAT | | | CREATION WITH WALKWAYS TO ALLOW ACCESS AND VIEWING OF | | | THE ENHANCED AREA. PROVIDE AN ANALYSIS OF THE | | | COMPARISON FOR TREE CANOPY CURRENTLY EXISTING AND THE | | | PROPOSED TREE CANOPY COVERAGE. | | | THE LANDSCAPING IN THE ADJACENT RIGHT OF WAY MUST BE | | | SHOWN ON THE LANDSCAPE PLAN AND ENHANCED TO PROVIDE A | | | CONTINUOUS DESIGN FOR THE AREA. SECTION 94-452 ROADWAY | | | BEAUTIFICATION APPLIES IN THIS CASE TO THE PD SO THE | | | LANDSCAPE SHOULD BE DESIGNED, INSTALLED AND MAINTAINED | | | BY THE PROPERTY OWNER AS PART OF THE ENHANCED AREA. | | | | | | | | | 5. PARTIALLY SATISFIED. SECTION 94-443 (C)(3)A. | | | REQUIRES A TERMINAL LANDSCAPE ISLAND AND REQUIRED TREE | | | FOR EACH ROW OF PARKING. (3)B. REQUIRES AN INTERIOR | | | LANDSCAPE ISLAND WITH A REQUIRED TREE SO THERE ARE NO | | | MORE THAN 10 SPACES IN A ROW. ALL THESE LANDSCAPE AREAS | | | MUST MEET THE MINIMUM WIDTH OF 8 FEET OF LANDSCAPE AREA | | | AND BE THE FULL LENGTH OF THE ADJACENT SPACE. (3) C. | | | REQUIRES DIVIDER MEDIANS WHERE THERE ARE MORE THAN 3 | | | CONSECUTIVE ROWS OF PARKING. ALL RECONSTRUCTED AREAS OF | | | PARKING MUST MEET THESE REQUIREMENTS, AND THE APPROVED | | | PLAN FOLLOWED FOR UNALTERED AREAS. | | | ALL AREAS OF PARKING ARE BEING RECONSTRUCTED SO PARKING | | | LOT LANDSCAPING REQUIREMENTS APPLY TO ALL AREAS. THE | | | DIVIDER MEDIANS MUST BE PROVIDED IF MORE THAN 3 | | | CONSECUTIVE ROWS OF PARKING. IF CHOOSING TO USE | | | 94-443(C)(6) B., THE INTERIOR ISLAND MUST BE SPLIT AND | | | ALTERNATED. NO ADDITIONAL TREE CANOPY HAS BEEN | | | PROVIDED. | | | THERE IS ONE LANDSCAPE ISLAND IN THE PARKING AREA SOUTH | | | OF BRANDSMART BUILDING THAT DOES NOT HAVE 2 TREES FOR | | | THE 2 ROWS OF PARKING. | | | PROVIDE DIMENSIONS FOR ALL LANDSCAPE ISLANDS AS THERE | | | APPEAR TO BE ONES IN THE EASTERN PARKING AREA THAT DO | | | NOT MEET THE MINIMUM WIDTH FOR THE FULL LENGTH OF THE | | | PARKING SPACE. NORTH EAST 4 L SHAPED LANDSCAPE ISLANDS. | | | 6/3/21 | | | | | | 6. PARTIALLY SATISFIED. SECTION 94-443(C)(3) REQUIRES | | | THAT A MINIMUM OF 75 PERCENT OF ALL TREES THAT ARE | | | REQUIRED TO BE PLANTED WITHIN THE INTERIOR OF AN OFF | | | STREET PARKING AREA SHALL BE CATEGORY 1 SHADE TREES. | | | SHOW THE PERCENTAGE OF CATEGORY 1 TREES PROVIDED FOR | | | THE REQUIRED LANDSCAPE AREAS AS REQUIRED BY SECTION | | | 94-443(C)(3) FOR DIVIDER ISLANDS, TERMINAL, AND | | | INTERIOR ISLANDS. | | | PROVIDE A LISTING OF THE TREES PROVIDED IN THE INTERIOR | | | PARKING ISLANDS BY SPECIES AND COUNT AND SHOW | | | PERCENTAGE CALCULATED. | | | | | | 7. SATISFIED. PROVIDE A PLAN SHOWING THE PARKING | | | LANDSCAPE AREAS COUNTED TOWARD COMPLIANCE WITH SECTION | | | 94-443(C)(3) AND (4) AND PROVIDE CALCULATIONS. PROVIDE | | | THE TOTAL REQUIRED AND PROVIDED AS ONE TOTAL FOR BOTH | | | SECTIONS. A SEPARATE EXHIBIT MUST BE PROVIDED TO | | | DEMONSTRATE THE AREAS COUNTED. | | | THERE SHOULD BE 3 AREAS SHOWN WITH DIFFERENT SHADING OR | | | GRAPHIC. PARKING SPACES, OTHER VEHICULAR USE AREAS AND | | | INTERIOR LANDSCAPE AREAS NEED TO BE IDENTIFIED AND | | | QUANTIFIED. SECTION 94-443 (C)FIGURE XIV-1 SHOULD BE | | | USED TO DISCERN INTERIOR LANDSCAPE AREAS. THERE ARE | | | ALSO SOME AREAS SHOWN ACROSS PARCEL LINES ON THE SHEETS | | | L-211 AND L-212. | | | | | | | | | 8. PROVIDE THE FOLLOWING CORRECTIONS TO TREE | | | DISPOSITION CHART SHEET L-101: | | | ? SATISFIED. PROVIDE A COMPLETE TREE SURVEY THAT | | | INCLUDES ALL EXISTING TREES AND PALMS. COMPLETE ALL | | | COLUMNS FOR MISSING INFORMATION. | | | ? SATISFIED. LIST OFF SITE TREES AND PALMS AS OFF SITE. | | | THESE WOULD REQUIRE A SEPARATE PERMIT FROM THE OWNER OF | | | THAT PROPERTY FOR REMOVAL. | | | ? SATISFIED. IF CANOPY DIAMETERS ARE 20 FEET OR MORE, | | | CALCULATE THE ACTUAL SQUARE FOOTAGE AND ENTER INTO THE | | | MITIGATION DUE COLUMN IF PROPOSED FOR REMOVAL. IF UNDER | | | 20 FEET, THE SQUARE FOOTAGE IS BASED ON THE CATEGORY | | | FOR THE TREE. | | | | | | ? SATISFIED. ADD A COLUMN AND LIST THE CATEGORY 1, 2, | | | 3, OR 4 FOR EACH TREE AND PALM FROM THE CITY REFERENCE | | | LIST. | | | | | | ? SATISFIED. REMOVE ?UNIDENTIFIED PALM? AND LIST THE | | | SCIENTIFIC AND COMMON NAME, AS ALL TREES MUST BE | | | PROPERLY IDENTIFIED. | | | ? SATISFIED. CHANGE CANOPY AREA COLUMN TO CANOPY | | | MITIGATION DUE, AND LIST SQUARE FOOTAGE IF MITIGATION | | | IS DUE. | | | ? SATISFIED. PROVIDE THE TOTAL SQUARE FOOTAGE OF | | | MITIGATION DUE AND SHOW MITIGATION SQUARE FOOTAGE | | | PROVIDED FROM THE PROPOSED TREE LIST AFTER ALL | | | CORRECTIONS. | | | | | | ? SATISFIED. INCLUDE A LIST OF ALL SPECIES AND | | | QUANTITIES COUNTED TOWARD MITIGATION BASED ON THE | | | LANDSCAPE PLAN, NOT INCLUDING REPLACEMENTS FOR MISSING | | | APPROVED TREES AND PALMS. | | | | | | | | | 9. SATISFIED. SECTION 94-448 (D)(3) REQUIRES NATIVE | | | TREES IN GOOD CONDITION TO BE PRESERVED ON SITE OR | | | RELOCATED. ANSI A 300 (PART 5) STANDARDS SPECIFY | | | EXAMPLES OF SUITABILITY RATINGS OF GOOD, MODERATE, OR | | | POOR FOR RELOCATION. PROVIDE CONDITION FOR ALL EXISTING | | | TREES AND PALMS AND RELOCATION POTENTIAL FOR THE NATIVE | | | TREES AND PALMS BASED ON A CERTIFIED ARBORISTS REPORT. | | | THE FOLLOWING SABAL PALMS AND ROYAL PALMS ARE LISTED IN | | | GOOD CONDITION ON THE ARBORIST REPORT YET ARE LISTED | | | FOR REMOVAL. PROVIDE AN EXPLANATION. SABAL PALM NUMBER: | | | 43, 44, 45, 229, 230, 231, 232, 233, 234, 235, 236, | | | 237, 238, 239, 240, 242, 243, 244, 245, 246, 247, 248, | | | 249, 250, 252, 253, 254, 255, 256, 257, 258, 264 | | | ROYAL PALM NUMBER: 146, 149, 151, 175, 176, 177, 193, | | | 195, 197, 201, 202, 218,219 | | | | | | | | | 10. SATISFIED. BUFFER LENGTHS REQUIRE ONE TREE PER 30 | | | FEET OR PORTION THEREOF FOR EACH BUFFER LENGTH. PROVIDE | | | THE REQUIRED AND PROVIDED BUFFER TREES IN A CHART WITH | | | THE INDIVIDUAL BUFFER SECTIONS IDENTIFIED. | | | PROVIDE THE BUFFER SECTIONS AND THE REQUIRED AND | | | PROVIDED TREES FOR EACH SECTION FOR BOTH PARCELS. THERE | | | WILL BE FOUR SECTIONS FOR EACH PARCEL WITH THE INTERIOR | | | LOT LINES INDICATED AS NOT PROVIDED PER THE WAIVER | | | REQUEST. SECTIONS CANNOT BE COMBINED. | | | | | | NOTE WITH LABEL REFERENCING SECTION 94-443(B)2 DOES NOT | | | APPLY, AS THERE IS NO VEHICLE INGRESS OR EGRESS AT THE | | | LOCATIONS ALONG I 95. | | | EXISTING DRAINAGE EASEMENT ALONG WESTERN BUFFER MAY BE | | | ABANDONED BY THE CITY IF NOT NEEDED, SO THIS AREA NEEDS | | | TO COMPLY WITH THE BUFFER REQUIREMENTS AND BE | | | COORDINATED WITH THE ADJOINING PROPERTY AND THE CITY. | | | | | | 11. SATISFIED. PROVIDE THE FOUNDATION PLANTING | | | CALCULATION REQUIRED AND PROVIDED FOR EACH BUILDING. | | | | | | 12. SATISFIED. REQUIRED TREES PER OPEN SPACE ARE NOT | | | PROVIDED, THIS WOULD REQUIRE A WAIVER. | | | THE REQUIRED OPEN SPACE CALCULATION SHOULD BE 40 | | | PERCENT OF THE TOTAL PARCEL SQUARE FOOTAGE. CORRECT FOR | | | EACH LOT AND RECALCULATE REQUIRED TREES, FLOWERING | | | TREES AND SHRUBS. | | | | | | 13. SATISFIED. PROVIDE THE NUMBER AND PERCENTAGE OF | | | SUBSTITUTION OF PALMS FOR REQUIRED TREES. SECTION | | | 94-442(D) REQUIRES A 3:1 RATIO FOR SUBSTITUTION FOR | | | PALMS EXCEPT THE LISTED 1:1 SPECIES. | | | COULD NOT LOCATE ON PLANS. | | | | | | 14. SATISFIED. ADD A SECTION IN THE LANDSCAPE DATA | | | CHART TO COMPLY WITH SECTION 94-445 L. PLANT SPECIES. A | | | MINIMUM OF 60 PERCENT OF PLANT MATERIAL ADDED SHALL BE | | | FLORIDA NATIVE OR DROUGHT TOLERANT SPECIES SELECTED | | | FROM THE CITY LIST OR THE LIST OF SPECIES IN THE MOST | | | RECENT EDITION OF SOUTH FLORIDA WATER MANAGEMENT | | | DISTRICT WATERWISE SOUTH FLORIDA LANDSCAPES. PROVIDE | | | THE TOTAL PERCENTAGE OF NATIVE AND DROUGHT TOLERANT | | | PLANTS BASED ON FINAL PLANT LIST. | | | COULD NOT LOCATE ON PLANS. | | | | | | | | | 15. SATISFIED. SHOW THE LOCATIONS OF ALL SITE LIGHTING | | | ON THE LANDSCAPE PLAN AND REDESIGN THE LOCATIONS OF THE | | | LIGHTING ON SHORTER POLES TO RESOLVE ANY CONFLICTS WITH | | | TREES IN THE PARKING AREA LANDSCAPE ISLANDS. | | | | | | 16. SATISFIED. PROVIDE SCREENING FOR ALL GROUND MOUNTED | | | VALVES AND EQUIPMENT. | | | ALL THE LOCATIONS NEED TO BE IDENTIFIED IN SOME WAY. | | | | | | 17. PARTIALLY SATISFIED. SHOW LOCATIONS OF FPL | | | TRANSFORMERS ON THE LANDSCAPE PLAN AND RESOLVE | | | CONFLICTS WITH LANDSCAPING. EXISTING UTILITIES CLOSE TO | | | FUEL STATION DO NOT APPEAR TO HAVE LANDSCAPE SCREEN | | | 6/2/21 | | | ALL THE LOCATIONS NEED TO BE IDENTIFIED IN SOME WAY. | | | | | | 18. SATISFIED. ADD A COLUMN TO THE PLANT LIST FOR | | | DROUGHT TOLERANT LEVELS OF EACH SPECIES. | | | | | | ADD A COLUMN INSTEAD OF ADDING THE INFORMATION UNDER | | | THE PLANT NAME. | | | | | | 19. SATISFIED. MINIMUM TREE SIZES ARE 12 FEET HEIGHT, | | | CORRECT ON PLANT LIST. | | | | | | SILVER BUTTONWOOD TREES ARE REQUIRED AT 12 FEET HEIGHT. | | | TREES ARE PROHIBITED FROM BEING TRIMMED INTO SHAPES AND | | | MUST BE ALLOWED TO DEVELOP INTO THEIR MATURE SIZE TO | | | FULFILL THE CODE REQUIREMENTS. PROVIDE REASON FOR | | | SMALLER SIZES AND SPECIES BEING USED IN BUFFERS AND | | | LANDSCAPE ISLANDS. | | | | | | 20. SATISFIED. THE OVERALL SCALE OF THE LANDSCAPE PLANS | | | NEEDS TO BE PROVIDED AT A MINIMUM 1:20 SCALE TO MAKE IT | | | POSSIBLE FOR THE DETAIL NEEDED FOR REVIEW. THE SCALE | | | NEEDS TO BE CALLED OUT ON THE PLAN. | | | | | | 21. SATISFIED. PROPOSED SUBDIVISION LINES NEED TO BE | | | INCLUDED ON THE LANDSCAPE PLAN AND IDENTIFY ALL BUFFER | | | SECTIONS AND INDICATE BUFFER PROVIDED OR NOT. | | | | | | ADDITIONAL COMMENTS 3/18/21: | | | | | | 22. PROVIDE DETAILED WRITTEN RESPONSES TO COMMENTS SO | | | STAFF DOES NOT HAVE TO SEARCH THE PLANS FOR THE | | | CORRECTIONS. | | | 23. SATISFIED THE ROWS OF PARKING ALONG THE SOUTH | | | BUFFER AND THE GAS AREA SHOULD HAVE THE CURB SHOWN AT | | | THE 16 FOOT MARK INSTEAD OF WHEEL STOPS TO ALLOW MORE | | | PERVIOUS AREA AS THE OVERHANG. | | | | | | 24. SATISFIED CORRECT TREES #153 AND 154 ON THE TREE | | | DISPOSITION PLAN TO MATCH THE ARBORIST EVALUATION. | | | | | | 25. SATISFIED THE BUILDING UNDER THE GAS UMP CANOPY | | | MUST SHOW THE 30% FOUNDATION LANDSCAPING REQUIRED. | | | | | | 26. SATISFIED ADD A NOTE TO THE PLAN THAT ALL GROUND | | | MOUNTED EQUIPMENT WILL BE SCREENED FROM VIEW PER CODE | | | REQUIREMENTS. | | | ADDITIONAL COMMENTS 6/3/21: | | | 27. PLANTS IN BIO/WETLAND AREA WITH TRIANGLE IN CIRCLE | | | SYMBOL ARE NOT LISTED IN PLANT LIST. ADD TO LIST. | | | 28. AS LISTED IN #17 SCREENING FOR UTILITIES DO NOT | | | APPEAR TO BE PRESENT BY FUEL STATION. | | | 29. AS LISTED IN #5 PROVIDE DIMENSIONS FOR ALL | | | LANDSCAPE ISLANDS AS THERE APPEAR TO BE ONES IN THE | | | EASTERN PARKING AREA THAT DO NOT MEET THE MINIMUM WIDTH | | | FOR THE FULL LENGTH OF THE PARKING SPACE. NORTH EAST | | | SECTION OF PARKING LOT 4 L SHAPED LANDSCAPE ISLANDS OF | | | CONCERN. DIMENSIONS SHOWN FOR WIDE PLANTING AREA BUT | | | NOT FOR THE NARROW PARTS OF CONCERN. | | | 30. MAINTENANCE NOTE: ON EAST SIDE OF BIO SWALE | | | COCOPLUMS SHOULD BE ALLOWED TO GROW PROVIDING 6-8 FT | | | SCREENING OF BUILDING . | | | | | | | | | | | | | | | CONDITIONS OF APPROVAL | | | 1. PRIOR TO THE REMOVAL OR RELOCATION OF ANY TREES ON | | | THE PROPERTY, A TREE ALTERATION PERMIT SHALL BE | | | SUBMITTED, REVIEWED AND APPROVED BY THE DEVELOPMENT | | | SERVICES DEPARTMENT, PLANNING DIVISION. | | | 2. THE APPLICANT, SUCCESSORS AND ASSIGNS SHALL BE | | | RESPONSIBLE FOR THE PERMITTING AND INSTALLATION OF THE | | | STREET TREES AND RIGHT OF WAY LANDSCAPING AND | | | IRRIGATION APPROVED WITH THIS PETITION. | | | 3. THE APPLICANT, SUCCESSORS AND ASSIGNS SHALL BE | | | RESPONSIBLE FOR THE MAINTENANCE OF THE ROAD RIGHT OF | | | WAY LANDSCAPING AND IRRIGATION. THIS WILL BE THROUGH A | | | SEPARATE MAINTENANCE AGREEMENT WITH THE CITY. | | | |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
2 |
Status |
F |
Date |
03-18-2021 |
|
|
Cont ID |
|
| Sent By |
rcaranci |
Date |
03-18-2021 |
Time |
11:21 |
Rev Time |
0.00 |
| Received By |
rcaranci |
Date |
03-18-2021 |
Time |
11:21 |
Sent To |
|
|
| Notes |
| 2021-03-18 11:23:01 | FROM: RAY CARANCI, SENIOR LANDSCAPE PLANNER | | | 561-822-1462 | | | PROJECT: BJ?S AT BRANDSMART CPD Z20070016 | | | MARCH 17, 2021 | | | I HAVE REVIEWED THE ABOVE REFERENCED PETITION, AND | | | PROVIDE THE FOLLOWING COMMENTS: | | | | | | 1. NOT SATISFIED. DESIGN GUIDELINES: | | | ? THE EXCEPTION TO THE LANDSCAPE BUFFER FOR WATER | | | BODIES OR I-95 IS NOT SUPPORTED BY STAFF. THE PERIMETER | | | OF THE BRANDSMART PD MUST HAVE THE REQUIRED BUFFER AS | | | STATED. | | | ? BUFFERS MAY BE ADJUSTED TO AVOID UTILITY EASEMENT | | | OVERLAP THAT WOULD PREVENT THE REQUIRED LANDSCAPING | | | FROM BEING ALLOWED. THIS IS REINFORCED BY THE EASEMENT | | | REQUIREMENT NOT BEING ALLOWED TO COUNT TOWARD BUFFER | | | REQUIREMENT. | | | ? ALL LANDSCAPE BUFFERS MUST MEET ALL THE REQUIREMENTS | | | OF ARTICLE XIV ?LANDSCAPING, LAND CLEARING, TREE | | | PROTECTION AND ARTIFICIAL TURF?. | | | ? ALL BUILDINGS MODIFIED OR ADDED MUST MEET THE 30 | | | PERCENT LINEAR FOOTAGE REQUIREMENT FOR FOUNDATION | | | LANDSCAPING. | | | THE DESIGN GUIDELINES ARE NO LONGER NEEDED FOR | | | LANDSCAPE ITEMS. NOW THAT THE SUBDIVISION REQUEST ONLY | | | CREATES 2 LOTS, CODE REQUIREMENTS CAN BE MET, OR A | | | WAIVER REQUESTED. | | | | | | 2. WAIVER REQUESTS. | | | ? SATISFIED. #1 SHOULD READ: PROPOSED -WAIVE THE FIVE | | | FOOT BUFFER REQUIREMENT FOR INTERIOR LOT LINES. | | | ? NOT SATISFIED. #5 UP TO18 PARKING SPACES IN A ROW FOR | | | NEW PARKING AREAS WOULD HAVE TO PROVIDE TREE CANOPY IN | | | SOME OTHER WAY TO MEET THE INTENT OF 94-443(C). OPTIONS | | | ARE CURRENTLY AVAILABLE IN THE CODE TO ALLOW UP TO 12 | | | SPACES IN A ROW BY EXPANDING THE LANDSCAPE ISLANDS. | | | THERE IS ALSO AN OPTION TO ELIMINATE PERIMETER | | | LANDSCAPE ISLANDS BY PROVIDING ALTERNATIVE AREAS FOR | | | TREE CANOPY. | | | THE SITE AND LANDSCAPE PLAN HAVE BEEN RECONFIGURED AND | | | THE 18 SPACES IS NOT APPLICABLE. | | | | | | | | | 3. NO LONGER APPLICABLE. A WAIVER FOR SECTION 94-243, | | | TABLE VII-3 COMMERCIAL DISTRICTS REGULATIONS REGARDING | | | OPEN SPACE REQUIREMENTS WOULD HAVE TO BE INCLUDED IF | | | 40% OPEN SPACE MINIMUM ON INDIVIDUAL LOTS IS NOT MET AS | | | THEY ARE DEVELOPED, AS THE MAXIMUM LOT COVERAGE AREA IS | | | 60%. OPEN SPACE BY CODE DEFINITION INCLUDES ALL AREAS | | | THAT ARE UNENCLOSED. THE MINIMUM LANDSCAPING IS 15%, | | | AND EACH LOT SHOULD BE ABLE TO MEET THIS REQUIREMENT. | | | | | | 4. PARTIALLY SATISFIED. PROVIDE THE LANDSCAPE PLAN | | | SHOWING EXISTING AND PROPOSED LANDSCAPE FOR THE LINEAR | | | PARK AREA. THE LANDSCAPE IMPROVEMENTS ARE TO BE | | | UPGRADES FOR THE EXISTING LANDSCAPE TO JUSTIFY | | | REDUCTIONS IN LANDSCAPE IN OTHER AREAS, SO THIS NEEDS | | | TO BE QUANTIFIED. THE ACTUAL AREA IS PROPOSED TO BE | | | REDUCED BY THE ADDITION OF PARKING. | | | | | | THE DESIGN PROVIDES LITTLE AREA FOR ACTUAL USE BY | | | PEOPLE AND THE BAHIA SOD IN THE DRAINAGE AREA DOES NOT | | | OFFER ANYTHING DIFFERENT FROM THE STANDARD DESIGN. | | | STAFF SUGGESTS ENHANCED PLANTINGS TO MEET THE INTENTION | | | OF THE BIOSWALE PROVIDING VISUAL INTEREST AND HABITAT | | | CREATION WITH WALKWAYS TO ALLOW ACCESS AND VIEWING OF | | | THE ENHANCED AREA. PROVIDE AN ANALYSIS OF THE | | | COMPARISON FOR TREE CANOPY CURRENTLY EXISTING AND THE | | | PROPOSED TREE CANOPY COVERAGE. | | | THE LANDSCAPING IN THE ADJACENT RIGHT OF WAY MUST BE | | | SHOWN ON THE LANDSCAPE PLAN AND ENHANCED TO PROVIDE A | | | CONTINUOUS DESIGN FOR THE AREA. SECTION 94-452 ROADWAY | | | BEAUTIFICATION APPLIES IN THIS CASE TO THE PD SO THE | | | LANDSCAPE SHOULD BE DESIGNED, INSTALLED AND MAINTAINED | | | BY THE PROPERTY OWNER AS PART OF THE ENHANCED AREA. | | | | | | | | | 5. PARTIALLY SATISFIED. SECTION 94-443 (C)(3)A. | | | REQUIRES A TERMINAL LANDSCAPE ISLAND AND REQUIRED TREE | | | FOR EACH ROW OF PARKING. (3)B. REQUIRES AN INTERIOR | | | LANDSCAPE ISLAND WITH A REQUIRED TREE SO THERE ARE NO | | | MORE THAN 10 SPACES IN A ROW. ALL THESE LANDSCAPE AREAS | | | MUST MEET THE MINIMUM WIDTH OF 8 FEET OF LANDSCAPE AREA | | | AND BE THE FULL LENGTH OF THE ADJACENT SPACE. (3) C. | | | REQUIRES DIVIDER MEDIANS WHERE THERE ARE MORE THAN 3 | | | CONSECUTIVE ROWS OF PARKING. ALL RECONSTRUCTED AREAS OF | | | PARKING MUST MEET THESE REQUIREMENTS, AND THE APPROVED | | | PLAN FOLLOWED FOR UNALTERED AREAS. | | | ALL AREAS OF PARKING ARE BEING RECONSTRUCTED SO PARKING | | | LOT LANDSCAPING REQUIREMENTS APPLY TO ALL AREAS. THE | | | DIVIDER MEDIANS MUST BE PROVIDED IF MORE THAN 3 | | | CONSECUTIVE ROWS OF PARKING. IF CHOOSING TO USE | | | 94-443(C)(6) B., THE INTERIOR ISLAND MUST BE SPLIT AND | | | ALTERNATED. NO ADDITIONAL TREE CANOPY HAS BEEN | | | PROVIDED. | | | THERE IS ONE LANDSCAPE ISLAND IN THE PARKING AREA SOUTH | | | OF BRANDSMART BUILDING THAT DOES NOT HAVE 2 TREES FOR | | | THE 2 ROWS OF PARKING. | | | PROVIDE DIMENSIONS FOR ALL LANDSCAPE ISLANDS AS THERE | | | APPEAR TO BE ONES IN THE EASTERN PARKING AREA THAT DO | | | NOT MEET THE MINIMUM WIDTH FOR THE FULL LENGTH OF THE | | | PARKING SPACE. | | | | | | 6. PARTIALLY SATISFIED. SECTION 94-443(C)(3) REQUIRES | | | THAT A MINIMUM OF 75 PERCENT OF ALL TREES THAT ARE | | | REQUIRED TO BE PLANTED WITHIN THE INTERIOR OF AN OFF | | | STREET PARKING AREA SHALL BE CATEGORY 1 SHADE TREES. | | | SHOW THE PERCENTAGE OF CATEGORY 1 TREES PROVIDED FOR | | | THE REQUIRED LANDSCAPE AREAS AS REQUIRED BY SECTION | | | 94-443(C)(3) FOR DIVIDER ISLANDS, TERMINAL, AND | | | INTERIOR ISLANDS. | | | PROVIDE A LISTING OF THE TREES PROVIDED IN THE INTERIOR | | | PARKING ISLANDS BY SPECIES AND COUNT AND SHOW | | | PERCENTAGE CALCULATED. | | | | | | 7. PARTIALLY SATISFIED. PROVIDE A PLAN SHOWING THE | | | PARKING LANDSCAPE AREAS COUNTED TOWARD COMPLIANCE WITH | | | SECTION 94-443(C)(3) AND (4) AND PROVIDE CALCULATIONS. | | | PROVIDE THE TOTAL REQUIRED AND PROVIDED AS ONE TOTAL | | | FOR BOTH SECTIONS. A SEPARATE EXHIBIT MUST BE PROVIDED | | | TO DEMONSTRATE THE AREAS COUNTED. | | | THERE SHOULD BE 3 AREAS SHOWN WITH DIFFERENT SHADING OR | | | GRAPHIC. PARKING SPACES, OTHER VEHICULAR USE AREAS AND | | | INTERIOR LANDSCAPE AREAS NEED TO BE IDENTIFIED AND | | | QUANTIFIED. SECTION 94-443 (C)FIGURE XIV-1 SHOULD BE | | | USED TO DISCERN INTERIOR LANDSCAPE AREAS. THERE ARE | | | ALSO SOME AREAS SHOWN ACROSS PARCEL LINES ON THE SHEETS | | | L-211 AND L-212. | | | | | | | | | 8. PROVIDE THE FOLLOWING CORRECTIONS TO TREE | | | DISPOSITION CHART SHEET L-101: | | | ? SATISFIED. PROVIDE A COMPLETE TREE SURVEY THAT | | | INCLUDES ALL EXISTING TREES AND PALMS. COMPLETE ALL | | | COLUMNS FOR MISSING INFORMATION. | | | ? SATISFIED. LIST OFF SITE TREES AND PALMS AS OFF SITE. | | | THESE WOULD REQUIRE A SEPARATE PERMIT FROM THE OWNER OF | | | THAT PROPERTY FOR REMOVAL. | | | ? SATISFIED. IF CANOPY DIAMETERS ARE 20 FEET OR MORE, | | | CALCULATE THE ACTUAL SQUARE FOOTAGE AND ENTER INTO THE | | | MITIGATION DUE COLUMN IF PROPOSED FOR REMOVAL. IF UNDER | | | 20 FEET, THE SQUARE FOOTAGE IS BASED ON THE CATEGORY | | | FOR THE TREE. | | | | | | ? SATISFIED. ADD A COLUMN AND LIST THE CATEGORY 1, 2, | | | 3, OR 4 FOR EACH TREE AND PALM FROM THE CITY REFERENCE | | | LIST. | | | | | | ? SATISFIED. REMOVE ?UNIDENTIFIED PALM? AND LIST THE | | | SCIENTIFIC AND COMMON NAME, AS ALL TREES MUST BE | | | PROPERLY IDENTIFIED. | | | ? SATISFIED. CHANGE CANOPY AREA COLUMN TO CANOPY | | | MITIGATION DUE, AND LIST SQUARE FOOTAGE IF MITIGATION | | | IS DUE. | | | ? SATISFIED. PROVIDE THE TOTAL SQUARE FOOTAGE OF | | | MITIGATION DUE AND SHOW MITIGATION SQUARE FOOTAGE | | | PROVIDED FROM THE PROPOSED TREE LIST AFTER ALL | | | CORRECTIONS. | | | | | | ? SATISFIED. INCLUDE A LIST OF ALL SPECIES AND | | | QUANTITIES COUNTED TOWARD MITIGATION BASED ON THE | | | LANDSCAPE PLAN, NOT INCLUDING REPLACEMENTS FOR MISSING | | | APPROVED TREES AND PALMS. | | | | | | | | | 9. PARTIALLY SATISFIED. SECTION 94-448 (D)(3) REQUIRES | | | NATIVE TREES IN GOOD CONDITION TO BE PRESERVED ON SITE | | | OR RELOCATED. ANSI A 300 (PART 5) STANDARDS SPECIFY | | | EXAMPLES OF SUITABILITY RATINGS OF GOOD, MODERATE, OR | | | POOR FOR RELOCATION. PROVIDE CONDITION FOR ALL EXISTING | | | TREES AND PALMS AND RELOCATION POTENTIAL FOR THE NATIVE | | | TREES AND PALMS BASED ON A CERTIFIED ARBORISTS REPORT. | | | THE FOLLOWING SABAL PALMS AND ROYAL PALMS ARE LISTED IN | | | GOOD CONDITION ON THE ARBORIST REPORT YET ARE LISTED | | | FOR REMOVAL. PROVIDE AN EXPLANATION. SABAL PALM NUMBER: | | | 43, 44, 45, 229, 230, 231, 232, 233, 234, 235, 236, | | | 237, 238, 239, 240, 242, 243, 244, 245, 246, 247, 248, | | | 249, 250, 252, 253, 254, 255, 256, 257, 258, 264 | | | ROYAL PALM NUMBER: 146, 149, 151, 175, 176, 177, 193, | | | 195, 197, 201, 202, 218,219 | | | | | | | | | 10. PARTIALLY SATISFIED. BUFFER LENGTHS REQUIRE ONE | | | TREE PER 30 FEET OR PORTION THEREOF FOR EACH BUFFER | | | LENGTH. PROVIDE THE REQUIRED AND PROVIDED BUFFER TREES | | | IN A CHART WITH THE INDIVIDUAL BUFFER SECTIONS | | | IDENTIFIED. | | | PROVIDE THE BUFFER SECTIONS AND THE REQUIRED AND | | | PROVIDED TREES FOR EACH SECTION FOR BOTH PARCELS. THERE | | | WILL BE FOUR SECTIONS FOR EACH PARCEL WITH THE INTERIOR | | | LOT LINES INDICATED AS NOT PROVIDED PER THE WAIVER | | | REQUEST. SECTIONS CANNOT BE COMBINED. | | | | | | NOTE WITH LABEL REFERENCING SECTION 94-443(B)2 DOES NOT | | | APPLY, AS THERE IS NO VEHICLE INGRESS OR EGRESS AT THE | | | LOCATIONS ALONG I 95. | | | EXISTING DRAINAGE EASEMENT ALONG WESTERN BUFFER MAY BE | | | ABANDONED BY THE CITY IF NOT NEEDED, SO THIS AREA NEEDS | | | TO COMPLY WITH THE BUFFER REQUIREMENTS AND BE | | | COORDINATED WITH THE ADJOINING PROPERTY AND THE CITY. | | | | | | 11. SATISFIED. PROVIDE THE FOUNDATION PLANTING | | | CALCULATION REQUIRED AND PROVIDED FOR EACH BUILDING. | | | | | | 12. PARTIALLY SATISFIED. REQUIRED TREES PER OPEN SPACE | | | ARE NOT PROVIDED, THIS WOULD REQUIRE A WAIVER. | | | THE REQUIRED OPEN SPACE CALCULATION SHOULD BE 40 | | | PERCENT OF THE TOTAL PARCEL SQUARE FOOTAGE. CORRECT FOR | | | EACH LOT AND RECALCULATE REQUIRED TREES, FLOWERING | | | TREES AND SHRUBS. | | | | | | 13. NOT SATISFIED. PROVIDE THE NUMBER AND PERCENTAGE OF | | | SUBSTITUTION OF PALMS FOR REQUIRED TREES. SECTION | | | 94-442(D) REQUIRES A 3:1 RATIO FOR SUBSTITUTION FOR | | | PALMS EXCEPT THE LISTED 1:1 SPECIES. | | | COULD NOT LOCATE ON PLANS. | | | | | | 14. NOT SATISFIED. ADD A SECTION IN THE LANDSCAPE DATA | | | CHART TO COMPLY WITH SECTION 94-445 L. PLANT SPECIES. A | | | MINIMUM OF 60 PERCENT OF PLANT MATERIAL ADDED SHALL BE | | | FLORIDA NATIVE OR DROUGHT TOLERANT SPECIES SELECTED | | | FROM THE CITY LIST OR THE LIST OF SPECIES IN THE MOST | | | RECENT EDITION OF SOUTH FLORIDA WATER MANAGEMENT | | | DISTRICT WATERWISE SOUTH FLORIDA LANDSCAPES. PROVIDE | | | THE TOTAL PERCENTAGE OF NATIVE AND DROUGHT TOLERANT | | | PLANTS BASED ON FINAL PLANT LIST. | | | COULD NOT LOCATE ON PLANS. | | | | | | | | | 15. SATISFIED. SHOW THE LOCATIONS OF ALL SITE LIGHTING | | | ON THE LANDSCAPE PLAN AND REDESIGN THE LOCATIONS OF THE | | | LIGHTING ON SHORTER POLES TO RESOLVE ANY CONFLICTS WITH | | | TREES IN THE PARKING AREA LANDSCAPE ISLANDS. | | | | | | 16. PARTIALLY SATISFIED. PROVIDE SCREENING FOR ALL | | | GROUND MOUNTED VALVES AND EQUIPMENT. | | | ALL THE LOCATIONS NEED TO BE IDENTIFIED IN SOME WAY. | | | | | | 17. PARTIALLY SATISFIED. SHOW LOCATIONS OF FPL | | | TRANSFORMERS ON THE LANDSCAPE PLAN AND RESOLVE | | | CONFLICTS WITH LANDSCAPING. | | | ALL THE LOCATIONS NEED TO BE IDENTIFIED IN SOME WAY. | | | | | | 18. NOT SATISFIED. ADD A COLUMN TO THE PLANT LIST FOR | | | DROUGHT TOLERANT LEVELS OF EACH SPECIES. | | | | | | ADD A COLUMN INSTEAD OF ADDING THE INFORMATION UNDER | | | THE PLANT NAME. | | | | | | 19. PARTIALLY SATISFIED. MINIMUM TREE SIZES ARE 12 FEET | | | HEIGHT, CORRECT ON PLANT LIST. | | | | | | SILVER BUTTONWOOD TREES ARE REQUIRED AT 12 FEET HEIGHT. | | | TREES ARE PROHIBITED FROM BEING TRIMMED INTO SHAPES AND | | | MUST BE ALLOWED TO DEVELOP INTO THEIR MATURE SIZE TO | | | FULFILL THE CODE REQUIREMENTS. PROVIDE REASON FOR | | | SMALLER SIZES AND SPECIES BEING USED IN BUFFERS AND | | | LANDSCAPE ISLANDS. | | | | | | 20. SATISFIED. THE OVERALL SCALE OF THE LANDSCAPE PLANS | | | NEEDS TO BE PROVIDED AT A MINIMUM 1:20 SCALE TO MAKE IT | | | POSSIBLE FOR THE DETAIL NEEDED FOR REVIEW. THE SCALE | | | NEEDS TO BE CALLED OUT ON THE PLAN. | | | | | | 21. SATISFIED. PROPOSED SUBDIVISION LINES NEED TO BE | | | INCLUDED ON THE LANDSCAPE PLAN AND IDENTIFY ALL BUFFER | | | SECTIONS AND INDICATE BUFFER PROVIDED OR NOT. | | | | | | ADDITIONAL COMMENTS 3/18/21: | | | | | | 22. PROVIDE DETAILED WRITTEN RESPONSES TO COMMENTS SO | | | STAFF DOES NOT HAVE TO SEARCH THE PLANS FOR THE | | | CORRECTIONS. | | | 23. THE ROWS OF PARKING ALONG THE SOUTH BUFFER AND THE | | | GAS AREA SHOULD HAVE THE CURB SHOWN AT THE 16 FOOT MARK | | | INSTEAD OF WHEEL STOPS TO ALLOW MORE PERVIOUS AREA AS | | | THE OVERHANG. | | | | | | 24. CORRECT TREES #153 AND 154 ON THE TREE DISPOSITION | | | PLAN TO MATCH THE ARBORIST EVALUATION. | | | | | | 25. THE BUILDING UNDER THE GAS UMP CANOPY MUST SHOW THE | | | 30% FOUNDATION LANDSCAPING REQUIRED. | | | | | | 26. ADD A NOTE TO THE PLAN THAT ALL GROUND MOUNTED | | | EQUIPMENT WILL BE SCREENED FROM VIEW PER CODE | | | REQUIREMENTS. | | | | | | | | | | | | CONDITIONS OF APPROVAL | | | 1. PRIOR TO THE REMOVAL OR RELOCATION OF ANY TREES ON | | | THE PROPERTY, A TREE ALTERATION PERMIT SHALL BE | | | SUBMITTED, REVIEWED AND APPROVED BY THE DEVELOPMENT | | | SERVICES DEPARTMENT, PLANNING DIVISION. | | | 2. THE APPLICANT, SUCCESSORS AND ASSIGNS SHALL BE | | | RESPONSIBLE FOR THE PERMITTING AND INSTALLATION OF THE | | | STREET TREES AND RIGHT OF WAY LANDSCAPING AND | | | IRRIGATION APPROVED WITH THIS PETITION. | | | 3. THE APPLICANT, SUCCESSORS AND ASSIGNS SHALL BE | | | RESPONSIBLE FOR THE MAINTENANCE OF THE ROAD RIGHT OF | | | WAY LANDSCAPING AND IRRIGATION. THIS WILL BE THROUGH A | | | SEPARATE MAINTENANCE AGREEMENT WITH THE CITY. | | | |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
1 |
Status |
F |
Date |
12-09-2020 |
|
|
Cont ID |
|
| Sent By |
rcaranci |
Date |
12-09-2020 |
Time |
15:41 |
Rev Time |
0.00 |
| Received By |
rcaranci |
Date |
12-09-2020 |
Time |
15:41 |
Sent To |
|
|
| Notes |
| 2020-12-09 15:42:37 | FROM: RAY CARANCI, SENIOR LANDSCAPE PLANNER | | | 561-822-1462 | | | PROJECT: BJ?S AT BRANDSMART CPD Z20070016 | | | DECEMBER 9, 2020 | | | I HAVE REVIEWED THE ABOVE REFERENCED PETITION, AND | | | PROVIDE THE FOLLOWING COMMENTS: | | | | | | 1. DESIGN GUIDELINES: | | | ? THE EXCEPTION TO THE LANDSCAPE BUFFER FOR WATER | | | BODIES OR I-95 IS NOT SUPPORTED BY STAFF. THE PERIMETER | | | OF THE BRANDSMART PD MUST HAVE THE REQUIRED BUFFER AS | | | STATED. | | | ? BUFFERS MAY BE ADJUSTED TO AVOID UTILITY EASEMENT | | | OVERLAP THAT WOULD PREVENT THE REQUIRED LANDSCAPING | | | FROM BEING ALLOWED. THIS IS REINFORCED BY THE EASEMENT | | | REQUIREMENT NOT BEING ALLOWED TO COUNT TOWARD BUFFER | | | REQUIREMENT. | | | ? ALL LANDSCAPE BUFFERS MUST MEET ALL THE REQUIREMENTS | | | OF ARTICLE XIV ?LANDSCAPING, LAND CLEARING, TREE | | | PROTECTION AND ARTIFICIAL TURF?. | | | ? ALL BUILDINGS MODIFIED OR ADDED MUST MEET THE 30 | | | PERCENT LINEAR FOOTAGE REQUIREMENT FOR FOUNDATION | | | LANDSCAPING. | | | | | | 2. WAIVER REQUESTS. | | | ? #1 SHOULD READ: PROPOSED -WAIVE THE FIVE FOOT BUFFER | | | REQUIREMENT FOR INTERIOR LOT LINES. | | | ? #5 UP TO18 PARKING SPACES IN A ROW FOR NEW PARKING | | | AREAS WOULD HAVE TO PROVIDE TREE CANOPY IN SOME OTHER | | | WAY TO MEET THE INTENT OF 94-443(C). OPTIONS ARE | | | CURRENTLY AVAILABLE IN THE CODE TO ALLOW UP TO 12 | | | SPACES IN A ROW BY EXPANDING THE LANDSCAPE ISLANDS. | | | THERE IS ALSO AN OPTION TO ELIMINATE PERIMETER | | | LANDSCAPE ISLANDS BY PROVIDING ALTERNATIVE AREAS FOR | | | TREE CANOPY. | | | | | | | | | 3. A WAIVER FOR SECTION 94-243, TABLE VII-3 COMMERCIAL | | | DISTRICTS REGULATIONS REGARDING OPEN SPACE REQUIREMENTS | | | WOULD HAVE TO BE INCLUDED IF 40% OPEN SPACE MINIMUM ON | | | INDIVIDUAL LOTS IS NOT MET AS THEY ARE DEVELOPED, AS | | | THE MAXIMUM LOT COVERAGE AREA IS 60%. OPEN SPACE BY | | | CODE DEFINITION INCLUDES ALL AREAS THAT ARE UNENCLOSED. | | | THE MINIMUM LANDSCAPING IS 15%, AND EACH LOT SHOULD BE | | | ABLE TO MEET THIS REQUIREMENT. | | | | | | 4. PROVIDE THE LANDSCAPE PLAN SHOWING EXISTING AND | | | PROPOSED LANDSCAPE FOR THE LINEAR PARK AREA. THE | | | LANDSCAPE IMPROVEMENTS ARE TO BE UPGRADES FOR THE | | | EXISTING LANDSCAPE TO JUSTIFY REDUCTIONS IN LANDSCAPE | | | IN OTHER AREAS, SO THIS NEEDS TO BE QUANTIFIED. THE | | | ACTUAL AREA IS PROPOSED TO BE REDUCED BY THE ADDITION | | | OF PARKING. | | | | | | | | | 5. SECTION 94-443 (C)(3)A. REQUIRES A TERMINAL | | | LANDSCAPE ISLAND AND REQUIRED TREE FOR EACH ROW OF | | | PARKING. (3)B. REQUIRES AN INTERIOR LANDSCAPE ISLAND | | | WITH A REQUIRED TREE SO THERE ARE NO MORE THAN 10 | | | SPACES IN A ROW. ALL THESE LANDSCAPE AREAS MUST MEET | | | THE MINIMUM WIDTH OF 8 FEET OF LANDSCAPE AREA AND BE | | | THE FULL LENGTH OF THE ADJACENT SPACE. (3) C. REQUIRES | | | DIVIDER MEDIANS WHERE THERE ARE MORE THAN 3 CONSECUTIVE | | | ROWS OF PARKING. ALL RECONSTRUCTED AREAS OF PARKING | | | MUST MEET THESE REQUIREMENTS, AND THE APPROVED PLAN | | | FOLLOWED FOR UNALTERED AREAS. | | | | | | 6. SECTION 94-443(C)(3) REQUIRES THAT A MINIMUM OF 75 | | | PERCENT OF ALL TREES THAT ARE REQUIRED TO BE PLANTED | | | WITHIN THE INTERIOR OF AN OFF STREET PARKING AREA SHALL | | | BE CATEGORY 1 SHADE TREES. SHOW THE PERCENTAGE OF | | | CATEGORY 1 TREES PROVIDED FOR THE REQUIRED LANDSCAPE | | | AREAS AS REQUIRED BY SECTION 94-443(C)(3) FOR DIVIDER | | | ISLANDS, TERMINAL, AND INTERIOR ISLANDS. | | | | | | 7. PROVIDE A PLAN SHOWING THE PARKING LANDSCAPE AREAS | | | COUNTED TOWARD COMPLIANCE WITH SECTION 94-443(C)(3) AND | | | (4) AND PROVIDE CALCULATIONS. PROVIDE THE TOTAL | | | REQUIRED AND PROVIDED AS ONE TOTAL FOR BOTH SECTIONS. A | | | SEPARATE EXHIBIT MUST BE PROVIDED TO DEMONSTRATE THE | | | AREAS COUNTED. | | | | | | | | | 8. PROVIDE THE FOLLOWING CORRECTIONS TO TREE | | | DISPOSITION CHART SHEET L-101: | | | ? PROVIDE A COMPLETE TREE SURVEY THAT INCLUDES ALL | | | EXISTING TREES AND PALMS. COMPLETE ALL COLUMNS FOR | | | MISSING INFORMATION. | | | ? LIST OFF SITE TREES AND PALMS AS OFF SITE. THESE | | | WOULD REQUIRE A SEPARATE PERMIT FROM THE OWNER OF THAT | | | PROPERTY FOR REMOVAL. | | | ? IF CANOPY DIAMETERS ARE 20 FEET OR MORE, CALCULATE | | | THE ACTUAL SQUARE FOOTAGE AND ENTER INTO THE MITIGATION | | | DUE COLUMN IF PROPOSED FOR REMOVAL. IF UNDER 20 FEET, | | | THE SQUARE FOOTAGE IS BASED ON THE CATEGORY FOR THE | | | TREE. | | | | | | ? ADD A COLUMN AND LIST THE CATEGORY 1, 2, 3, OR 4 FOR | | | EACH TREE AND PALM FROM THE CITY REFERENCE LIST. | | | | | | ? REMOVE ?UNIDENTIFIED PALM? AND LIST THE SCIENTIFIC | | | AND COMMON NAME, AS ALL TREES MUST BE PROPERLY | | | IDENTIFIED. | | | ? CHANGE CANOPY AREA COLUMN TO CANOPY MITIGATION DUE, | | | AND LIST SQUARE FOOTAGE IF MITIGATION IS DUE. | | | ? PROVIDE THE TOTAL SQUARE FOOTAGE OF MITIGATION DUE | | | AND SHOW MITIGATION SQUARE FOOTAGE PROVIDED FROM THE | | | PROPOSED TREE LIST AFTER ALL CORRECTIONS. | | | | | | ? INCLUDE A LIST OF ALL SPECIES AND QUANTITIES COUNTED | | | TOWARD MITIGATION BASED ON THE LANDSCAPE PLAN, NOT | | | INCLUDING REPLACEMENTS FOR MISSING APPROVED TREES AND | | | PALMS. | | | | | | | | | 9. SECTION 94-448 (D)(3) REQUIRES NATIVE TREES IN GOOD | | | CONDITION TO BE PRESERVED ON SITE OR RELOCATED. ANSI A | | | 300 (PART 5) STANDARDS SPECIFY EXAMPLES OF SUITABILITY | | | RATINGS OF GOOD, MODERATE, OR POOR FOR RELOCATION. | | | PROVIDE CONDITION FOR ALL EXISTING TREES AND PALMS AND | | | RELOCATION POTENTIAL FOR THE NATIVE TREES AND PALMS | | | BASED ON A CERTIFIED ARBORISTS REPORT. | | | | | | 10. BUFFER LENGTHS REQUIRE ONE TREE PER 30 FEET OR | | | PORTION THEREOF FOR EACH BUFFER LENGTH. PROVIDE THE | | | REQUIRED AND PROVIDED BUFFER TREES IN A CHART WITH THE | | | INDIVIDUAL BUFFER SECTIONS IDENTIFIED. | | | | | | 11. PROVIDE THE FOUNDATION PLANTING CALCULATION | | | REQUIRED AND PROVIDED FOR EACH BUILDING. | | | | | | 12. REQUIRED TREES PER OPEN SPACE ARE NOT PROVIDED, | | | THIS WOULD REQUIRE A WAIVER. | | | | | | 13. PROVIDE THE NUMBER AND PERCENTAGE OF SUBSTITUTION | | | OF PALMS FOR REQUIRED TREES. SECTION 94-442(D) REQUIRES | | | A 3:1 RATIO FOR SUBSTITUTION FOR PALMS EXCEPT THE | | | LISTED 1:1 SPECIES. | | | | | | 14. ADD A SECTION IN THE LANDSCAPE DATA CHART TO COMPLY | | | WITH SECTION 94-445 L. PLANT SPECIES. A MINIMUM OF 60 | | | PERCENT OF PLANT MATERIAL ADDED SHALL BE FLORIDA NATIVE | | | OR DROUGHT TOLERANT SPECIES SELECTED FROM THE CITY LIST | | | OR THE LIST OF SPECIES IN THE MOST RECENT EDITION OF | | | SOUTH FLORIDA WATER MANAGEMENT DISTRICT WATERWISE SOUTH | | | FLORIDA LANDSCAPES. PROVIDE THE TOTAL PERCENTAGE OF | | | NATIVE AND DROUGHT TOLERANT PLANTS BASED ON FINAL PLANT | | | LIST. | | | | | | 15. SHOW THE LOCATIONS OF ALL SITE LIGHTING ON THE | | | LANDSCAPE PLAN AND REDESIGN THE LOCATIONS OF THE | | | LIGHTING ON SHORTER POLES TO RESOLVE ANY CONFLICTS WITH | | | TREES IN THE PARKING AREA LANDSCAPE ISLANDS. | | | | | | 16. PROVIDE SCREENING FOR ALL GROUND MOUNTED VALVES AND | | | EQUIPMENT. | | | | | | 17. SHOW LOCATIONS OF FPL TRANSFORMERS ON THE LANDSCAPE | | | PLAN AND RESOLVE CONFLICTS WITH LANDSCAPING. | | | | | | 18. ADD A COLUMN TO THE PLANT LIST FOR DROUGHT TOLERANT | | | LEVELS OF EACH SPECIES. | | | | | | 19. MINIMUM TREE SIZES ARE 12 FEET HEIGHT, CORRECT ON | | | PLANT LIST. | | | | | | 20. THE OVERALL SCALE OF THE LANDSCAPE PLANS NEEDS TO | | | BE PROVIDED AT A MINIMUM 1:20 SCALE TO MAKE IT POSSIBLE | | | FOR THE DETAIL NEEDED FOR REVIEW. THE SCALE NEEDS TO BE | | | CALLED OUT ON THE PLAN. | | | | | | 21. PROPOSED SUBDIVISION LINES NEED TO BE INCLUDED ON | | | THE LANDSCAPE PLAN, AND IDENTIFY ALL BUFFER SECTIONS | | | AND INDICATE BUFFER PROVIDED OR NOT. | | | | | | | | | | | | CONDITIONS OF APPROVAL | | | 1. PRIOR TO THE REMOVAL OR RELOCATION OF ANY TREES ON | | | THE PROPERTY, A TREE ALTERATION PERMIT SHALL BE | | | SUBMITTED, REVIEWED AND APPROVED BY THE DEVELOPMENT | | | SERVICES DEPARTMENT, PLANNING DIVISION. | | | |
|
|
| Review Stop |
PW |
PUBLIC WORKS |
| Rev No |
2 |
Status |
P |
Date |
02-24-2021 |
|
|
Cont ID |
|
| Sent By |
|
Date |
02-24-2021 |
Time |
|
Rev Time |
0.00 |
| Received By |
|
Date |
02-24-2021 |
Time |
|
Sent To |
|
|
| Notes |
| 2021-02-24 16:25:10 | NO FURTHER COMMENTS FROM DEPARTMENT OF PUBLIC WORKS. | | | | | | MATT HEJAZI | | | [email protected] | | | 561-822-2045 | | | |
|
|
| Review Stop |
PW |
PUBLIC WORKS |
| Rev No |
1 |
Status |
F |
Date |
11-30-2020 |
|
|
Cont ID |
|
| Sent By |
|
Date |
11-30-2020 |
Time |
|
Rev Time |
|
| Received By |
|
Date |
11-30-2020 |
Time |
|
Sent To |
|
|
| Notes |
| 2020-11-30 09:33:18 | PLEASE PROVIDE THE FOLLOWINGS: | | | 1- LOS (LEVEL OF SERVICE ANALYSIS) TO REFLECT THE SOLID | | | WASTE VOLUME PRODUCED ALONG WITH THE SIZE AND TYPE OF | | | THE CONTAINER (I.E. DUMPSTER/COMPACTOR) THAT WILL BE | | | UTILIZED THAT WILL BE UTILIZED FOR THE SANITATION | | | SERVICE. | | | 2- DUMPSTER/COMPACTOR ENCLOSURE DETAIL. FOR A | | | FREESTANDING SITE DUMPSTER ENCLOSURE, THE ENCLOSURE | | | SHALL COMPLY WITH THE LATEST REVISION OF CITY OF WEST | | | PALM BEACH GENERAL CONSTRUCTION-GARBAGE ENCLOSURE | | | STANDARD, GC-7. | | | 3- AUTO TURN (DYNAMIC ENVELOPE AND THE TIRES PATH) FOR | | | THE SANITATION SERVICE, FRONT LOADER TRUCK WITH THE | | | FOLLOWING SPECS: | | | - TRUCK LENGTH: 35 FT | | | - TRUCK WIDTH: 11 FT | | | - TURNING RADIUS: | | | - SAE TURNING RADIUS: 32.5 FT | | | - CURB-TO-CURB DIAMETER: 74 FT | | | - WALL-TO-WALL DIAMETER: 86.3 FT | | | | | | MATT HEJAZI | | | DEPT. OF PUBLIC WORKS | | | [email protected] | | | 561-822-2045 | | | |
|
|
| Review Stop |
STORM |
STORMWATER |
| Rev No |
4 |
Status |
P |
Date |
07-07-2021 |
|
|
Cont ID |
|
| Sent By |
tward |
Date |
07-07-2021 |
Time |
15:07 |
Rev Time |
0.00 |
| Received By |
tward |
Date |
07-07-2021 |
Time |
15:07 |
Sent To |
|
|
| Notes |
| 2021-07-07 15:07:21 | THE FOLLOWING COMMENTS ARE FROM THE REVIEW OF THE | | | 6/18/2021 SUBMITTAL. ONLY COMMENT #2 CAN POSSIBLY | | | AFFECT THE SITE PLAN. | | | | | | 1. [NOT SATISFIED] THIS COMMENT CAN BE ADDRESSED DURING | | | ENGINEERING PERMIT SUBMITTAL. SFWMD APPEARS TO HAVE | | | STOMRWATER AS-BUILT DRAWINGS ON ITS WEBSITE FOR THE ERP | | | PERMIT FOR EXECUTIVE CENTER DRIVE. PREVIOUS COMMENT: ON | | | THE DRAINAGE PLAN, PROVIDE PIPE SIZES AND PIPE MATERIAL | | | FOR EXISTING STORM PIPES, SEWER MAINS, FORCE MAINS AND | | | WATER MAINS. {ADDITIONAL COMMENT: NOT ALL EXISTING | | | UTILITIES ARE LABELED INCLUDING WITHIN THE EXECUTIVE | | | CENTER DRIVE R/W.] | | | | | | 2. [NOT SATISFIED] THIS CAN BE ADDRESSED DURING | | | ENGINEERING PERMIT SUBMITTAL PROVIDED THE SOLUTION DOES | | | NOT AFFECT THE STORMWATER DETENION AREAS. THIS COMMENT | | | WAS DISCUSSED WITH THE EOR. HE WILL MODIFY THE END | | | TREATMENT OF THE PIPE AT THE SOUTH END OF THE SOUTH | | | STORMWATER DETENTION AREA, LIKELY WITH A MITERED END | | | SECTION. THE PROPOSED GRATE ELEVATION (13.00) OF THE | | | CONFLICT STRUCTURE IS SHOWN TO BE LOWER THAN THE | | | INTERMEDIATE CONTOIUR ELEVATION (13.5 FEET) OVER THE | | | SANITARY SEWER PIPE AT THE NORTH END OF THE NORTH | | | DETENTION AREA. NOTE(S) SHOULD BE ADDED TO THE PLANS TO | | | RESTRICT HEAVY EQUIPMEINT OVER UTILITY PIPES WITH | | | INSUFFICIENT COVER DEPTH TO PROTECT THE PIPES FROM THE | | | WEIGHT OF THE EQUIPEMENT. PREVIOUS COMMENT: CHECK PIPE | | | COVER FOR PIPES WITHIN THE PROPOSED DRY DETENTION | | | AREAS. [ADDITIONAL COMMENTS: FOR EXAMPLE, THE SANITARY | | | SEWER PIPE LEAVING PROPOSED SEWER MANHOLE NUMBER 1 WILL | | | HAVE A TOP OF PIPE ELEVATION AROUND 12.4 FT NAVD AND | | | THE CONFLICT MANHOLE TO THE EAST WILL BE CONVERTED TO A | | | CATCH BASIN WITH PROPOSED GRATE ELEVATION OF 13.00 FT | | | NAVD WITHIN THE PROPOSED DETENTION AREA. FOR ANOTHER | | | EXAMPLE, THE PROPOSED BOTTOM ELEVATION OF THE DETENTION | | | AREA IS 10.50 FT NAVD. THE EXISTING CATCH BASIN TO THE | | | SOUTHWEST OF THE G-G SECTION LABEL ON SHEET C402.0 WILL | | | BE MODIFIED TO HAVE A GRATE ELEVATION OF 12.50 FT NAVD. | | | THE INVERT ELEVATION OF THE SOUTH PIPE IS 9.41 FT NAVD. | | | ASSUMING THE PIPE IS 12 INCHES IN DIAMETER, THE TOP OF | | | PIPE ELEVATION WILL BE 10.5?+/- NAVD, THE SAME | | | ELEVATION AS THE BOTTOM OF THE PROPOSED DETENTION | | | AREA.] | | | | | | 3. [SATISFIED] REVIEW GRATE ELEVATION OF 14.80 FT NAVD | | | FOR CATCH BASIN LOCATED IN NORTH DRIVEWAY. DRIVEWAY | | | CROSS SLOPE WOULD BE AROUND 3.5% AND LONGITUDINAL SLOPE | | | AROUND 2%. CONSIDER FLUME INTO THE DRY DETENTION AREA | | | INSTEAD OF THIS CATCH BASIN. SHEET C401.0 LISTS THE RIM | | | ELEVATION AS 14.80 FT NAVD AND SHEET C402.0 PROVIDES A | | | PROPOSED SPOT GRADE OF 15.05 FT NAVD AT THE CATCH | | | BASIN. | | | | | | 4. [SATISFIED] THE STORM PIPE FROM BEST BUY IS SHOWN AS | | | A SANITARY PIPE AND MAY NOT BE SHOWN IN THE CORRECT | | | LOCATION. THE PIPE FROM THE SOUTHEAST CORNER OF BEST | | | BUY IS LIKELY IN THE 12 FT DRAINAGE EASEMENT AND EITHER | | | CONNECTS TO THE MANHOLE IN THE DRIVEWAY OR CONTINUES | | | EAST TO THE DITCH ON THE OTHER SIDE OF EXECUTIVE CENTER | | | DRIVE. PLEASE VERIFY. | | | | | | 5. [SATISFIED] THE STORM PIPE FROM THE CENTER OF | | | EXECUTIVE CENTER DRIVE CONNECTS TO THE MANHOLE IN THE | | | NORTH DRIVEWAY INSTEAD OF THE OFFSITE CATCH BASIN. | | | | | | 6. [SATISFIED] PLEASE EXPLAIN THE PURPOSE OF THE WEIR | | | IN THE PROPOSED CONTROL STRUCTURE IF THE ELEVATED CATCH | | | BASINS IN THE PROPOSED DETENTION AREA ARE DESIGNED TO | | | PROVIDE THE PRE-TREATMENT STORAGE VOLUME. ALSO EXPLAIN | | | HOW THE DETENTION AREAS WILL PROVIDE TREATMENT WITH AN | | | PVC LINER. | | | | | | 7. [SATISFIED] PROVIDE CROSS SECTION OF ROAD WIDENING | | | (RIGHT TURN LANE). [ADDITIONAL COMMENT: PROVIDE RANGE | | | OF PAVEMENT CROSS SLOPE ON THE CROSS SECTION.] | | | | | | 8. [SATISFIED] PROVIDE SPOT GRADES FOR NEW RIGHT TURN | | | LANE AND AT DRIVEWAYS. {ADDITIONAL COMMENT: PROV IDE | | | ADDITIONAL GRADING FOR SIDEWALK AND DRIVEWAY APRON TO | | | SHOW HOW BACK OF SIDEWALK ELEVATION OF 15.85 FT NAVD AT | | | THE DRIVEWAY WILL CONNECT TO THE EXISTING EP ELEVATION | | | OF 14.12 FT NAVD IN THE STREET.] | | | | | | | | | 9. [SATISFIED] DRY DETENTION AREA IS NOT DEPICTED ON | | | THE WATER MAIN PROFILE OR FORCE MAIN PROFILE ON SHEET | | | C503.0. | | | | | | 10. [SATISFIED] 6? WATER MAIN TO THE FIRE HYDRANT | | | LABELED AS 10? WATER MAIN ON THE FORCE MAIN PROFILE. | | | | | | 11. [SATISFIED] PROVIDE VERTICAL DATUM CONVERSION | | | EQUATION ON THE SURVEY. [ADDITIONAL COMMENT: NAVD TO | | | NGVD CONVERSION IS LISTED AS +1.555 FEET ON THE SURVEY | | | AND +1.532 FEET ON THE CIVIL ENGINEERING PLANS.] | | | ADDITIONAL COMMENTS: | | | 12. PROVIDE INLET PROTECTION FOR ALL CATCH BASINS AND | | | INLETS ON EXECUTIVE CENTER DRIVE ALONG THE FRONTAGE OF | | | THE PROJECT AND IMMEDIATELY NORTH AND SOUTH OF THE | | | PROJECT. [CAN BE ADDRESSED DURING ENGINEERING PERMIT | | | SUBMITTAL] | | | | | | 13. [SATISFIED] SILT FENCE WILL BE NEEDED ALONG THE | | | WEST PROPERTY LINE. [CAN BE ADDRESSED DURING | | | ENGINEERING PERMIT SUBMITTAL] | | | | | | 14. [NOT SATISFIED] CAN BE ADDRESSED DURING ENGINEERING | | | PERMIT SUBMITTAL. ENGINEER SHOULD PROVIDE PRE- AND | | | POST- SPREAD CALCULAITONS AT THE CURB LINE DOWNSTREAM | | | OF THE RIGHT TURN LANES/DRIVEWAYS. ADDITIONAL CATCH | | | BASIN(S) MAY BE NEEDED WITHIN THE RIGHT TURN LANE | | | WIDENING. PREVIOUS COMMENT: CHECK THE CHANGE IN SPREAD | | | OF RUNOFF AT THE SOUTH END OF THE PROPOSED RIGHT TURN | | | LANE AT THE PT OF THE CURB AND GUTTER (I.E. AT THE EDGE | | | OF TRAVEL LANE SOUTH OF THE DRIVEWAY). [CAN BE | | | ADDRESSED DURING ENGINEERING PERMIT SUBMITTAL). | | | | | | TRACY WARD, P.E. | | | SENIOR STORMWATER ENGINEER | | | ENGINEERING SERVICES DEPARTMENT | | | [email protected] | | | 561-494-1120 (O) | | | 561-351-0510 (M) |
|
|
| Review Stop |
STORM |
STORMWATER |
| Rev No |
3 |
Status |
F |
Date |
06-09-2021 |
|
|
Cont ID |
|
| Sent By |
tward |
Date |
06-09-2021 |
Time |
07:15 |
Rev Time |
0.00 |
| Received By |
tward |
Date |
06-09-2021 |
Time |
07:15 |
Sent To |
|
|
| Notes |
| 2021-06-09 07:15:22 | THE FOLLOWING COMMENTS ARE FROM THE REVIEW OF THE | | | 5/18/2021 SUBMITTAL: | | | | | | 1. [NOT SATISFIED] ON THE DRAINAGE PLAN, PROVIDE PIPE | | | SIZES AND PIPE MATERIAL FOR EXISTING STORM PIPES, SEWER | | | MAINS, FORCE MAINS AND WATER MAINS. {ADDITIONAL | | | COMMENT: NOT ALL EXISTING UTILITIES ARE LABELED | | | INCLUDING WITHIN THE EXECUTIVE CENTER DRIVE R/W.] | | | | | | 2. [NOT SATISFIED] CHECK PIPE COVER FOR PIPES WITHIN | | | THE PROPOSED DRY DETENTION AREAS. [ADDITIONAL COMMENTS: | | | FOR EXAMPLE, THE SANITARY SEWER PIPE LEAVING PROPOSED | | | SEWER MANHOLE NUMBER 1 WILL HAVE A TOP OF PIPE | | | ELEVATION AROUND 12.4 FT NAVD AND THE CONFLICT MANHOLE | | | TO THE EAST WILL BE CONVERTED TO A CATCH BASIN WITH | | | PROPOSED GRATE ELEVATION OF 13.00 FT NAVD WITHIN THE | | | PROPOSED DETENTION AREA. FOR ANOTHER EXAMPLE, THE | | | PROPOSED BOTTOM ELEVATION OF THE DETENTION AREA IS | | | 10.50 FT NAVD. THE EXISTING CATCH BASIN TO THE | | | SOUTHWEST OF THE G-G SECTION LABEL ON SHEET C402.0 WILL | | | BE MODIFIED TO HAVE A GRATE ELEVATION OF 12.50 FT NAVD. | | | THE INVERT ELEVATION OF THE SOUTH PIPE IS 9.41 FT NAVD. | | | ASSUMING THE PIPE IS 12? IN DIAMETER, THE TOP OF PIPE | | | ELEVATION WILL BE 10.5?+/- NAVD, THE SAME ELEVATION AS | | | THE BOTTOM OF THE PROPOSED DETENTION AREA.] | | | | | | 3. [PARTIALLY SATISFIED] REVIEW GRATE ELEVATION OF | | | 14.80 FT NAVD FOR CATCH BASIN LOCATED IN NORTH | | | DRIVEWAY. DRIVEWAY CROSS SLOPE WOULD BE AROUND 3.5% AND | | | LONGITUDINAL SLOPE AROUND 2%. CONSIDER FLUME INTO THE | | | DRY DETENTION AREA INSTEAD OF THIS CATCH BASIN. SHEET | | | C401.0 LISTS THE RIM ELEVATION AS 14.80 FT NAVD AND | | | SHEET C402.0 PROVIDES A PROPOSED SPOT GRADE OF 15.05 FT | | | NAVD AT THE CATCH BASIN. | | | | | | 4. [SATISFIED] THE STORM PIPE FROM BEST BUY IS SHOWN AS | | | A SANITARY PIPE AND MAY NOT BE SHOWN IN THE CORRECT | | | LOCATION. THE PIPE FROM THE SOUTHEAST CORNER OF BEST | | | BUY IS LIKELY IN THE 12 FT DRAINAGE EASEMENT AND EITHER | | | CONNECTS TO THE MANHOLE IN THE DRIVEWAY OR CONTINUES | | | EAST TO THE DITCH ON THE OTHER SIDE OF EXECUTIVE CENTER | | | DRIVE. PLEASE VERIFY. | | | | | | 5. [SATISFIED] THE STORM PIPE FROM THE CENTER OF | | | EXECUTIVE CENTER DRIVE CONNECTS TO THE MANHOLE IN THE | | | NORTH DRIVEWAY INSTEAD OF THE OFFSITE CATCH BASIN. | | | | | | 6. [REVISED COMMENT] PLEASE EXPLAIN THE PURPOSE OF THE | | | WEIR IN THE PROPOSED CONTROL STRUCTURE IF THE ELEVATED | | | CATCH BASINS IN THE PROPOSED DETENTION AREA ARE | | | DESIGNED TO PROVIDE THE PRE-TREATMENT STORAGE VOLUME. | | | ALSO EXPLAIN HOW THE DETENTION AREAS WILL PROVIDE | | | TREATMENT WITH AN PVC LINER. | | | | | | 7. [PARTIALLY SATISFIED] PROVIDE CROSS SECTION OF ROAD | | | WIDENING (RIGHT TURN LANE). [ADDITIONAL COMMENT: | | | PROVIDE RANGE OF PAVEMENT CROSS SLOPE ON THE CROSS | | | SECTION.] | | | | | | 8. [PARTIALLY SATISFIED] PROVIDE SPOT GRADES FOR NEW | | | RIGHT TURN LANE AND AT DRIVEWAYS. {ADDITIONAL COMMENT: | | | PROV IDE ADDITIONAL GRADING FOR SIDEWALK AND DRIVEWAY | | | APRON TO SHOW HOW BACK OF SIDEWALK ELEVATION OF 15.85 | | | FT NAVD AT THE DRIVEWAY WILL CONNECT TO THE EXISTING EP | | | ELEVATION OF 14.12 FT NAVD IN THE STREET.] | | | | | | | | | 9. [SATISFIED] DRY DETENTION AREA IS NOT DEPICTED ON | | | THE WATER MAIN PROFILE OR FORCE MAIN PROFILE ON SHEET | | | C503.0. | | | | | | 10. [SATISFIED] 6? WATER MAIN TO THE FIRE HYDRANT | | | LABELED AS 10? WATER MAIN ON THE FORCE MAIN PROFILE. | | | | | | 11. [PARTIALLY SATISFIED] PROVIDE VERTICAL DATUM | | | CONVERSION EQUATION ON THE SURVEY. [ADDITIONAL COMMENT: | | | NAVD TO NGVD CONVERSION IS LISTED AS +1.555 FEET ON THE | | | SURVEY AND +1.532 FEET ON THE CIVIL ENGINEERING PLANS.] | | | ADDITIONAL COMMENTS: | | | 12. PROVIDE INLET PROTECTION FOR ALL CATCH BASINS AND | | | INLETS ON EXECUTIVE CENTER DRIVE ALONG THE FRONTAGE OF | | | THE PROJECT AND IMMEDIATELY NORTH AND SOUTH OF THE | | | PROJECT. [CAN BE ADDRESSED DURING ENGINEERING PERMIT | | | SUBMITTAL] | | | | | | 13. SILT FENCE WILL BE NEEDED ALONG THE WEST PROPERTY | | | LINE. [CAN BE ADDRESSED DURING ENGINEERING PERMIT | | | SUBMITTAL] | | | | | | 14. CHECK THE CHANGE IN SPREAD OF RUNOFF AT THE SOUTH | | | END OF THE PROPOSED RIGHT TURN LANE AT THE PT OF THE | | | CURB AND GUTTER (I.E. AT THE EDGE OF TRAVEL LANE SOUTH | | | OF THE DRIVEWAY). [CAN BE ADDRESSED DURING ENGINEERING | | | PERMIT SUBMITTAL). | | | | | | TRACY WARD, P.E. | | | SENIOR STORMWATER ENGINEER | | | ENGINEERING SERVICES DEPARTMENT | | | [email protected] | | | 561-494-1120 (O) | | | 561-351-0510 (M) | | | |
|
|
| Review Stop |
STORM |
STORMWATER |
| Rev No |
2 |
Status |
F |
Date |
03-17-2021 |
|
|
Cont ID |
|
| Sent By |
tward |
Date |
03-17-2021 |
Time |
02:43 |
Rev Time |
0.00 |
| Received By |
tward |
Date |
03-17-2021 |
Time |
02:46 |
Sent To |
|
|
| Notes |
| 2021-03-17 02:46:04 | THE FOLLOWING COMMENTS ARE FROM THE REVIEW OF THE | | | 2/24/2021 SUBMITTAL: | | | | | | 1. ON THE DRAINAGE PLAN, PROVIDE PIPE SIZES AND PIPE | | | MATERIAL FOR EXISTING STORM PIPES, SEWER MAINS, FORCE | | | MAINS AND WATER MAINS. | | | | | | 2. CHECK PIPE COVER FOR PIPES WITHIN THE PROPOSED DRY | | | DETENTION AREAS. | | | | | | 3. REVIEW GRATE ELEVATION OF 14.80? NAVD FOR CATCH | | | BASIN LOCATED IN NORTH DRIVEWAY. DRIVEWAY CROSS SLOPE | | | WOULD BE AROUND 3.5% AND LONGITUDINAL SLOPE AROUND 2%. | | | CONSIDER FLUME INTO THE DRY DETENTION AREA INSTEAD OF | | | THIS CATCH BASIN. | | | | | | 4. THE STORM PIPE FROM BEST BUY IS SHOWN AS A SANITARY | | | PIPE AND MAY NOT BE SHOWN IN THE CORRECT LOCATION. THE | | | PIPE FROM THE SOUTHEAST CORNER OF BEST BUY IS LIKELY IN | | | THE 12? DRAINAGE EASEMENT AND EITHER CONNECTS TO THE | | | MANHOLE IN THE DRIVEWAY OR CONTINUES EAST TO THE DITCH | | | ON THE OTHER SIDE OF EXECUTIVE CENTER DRIVE. PLEASE | | | VERIFY. | | | | | | 5. THE STORM PIPE FROM THE CENTER OF EXECUTIVE CENTER | | | DRIVE CONNECTS TO THE MANHOLE IN THE NORTH DRIVEWAY | | | INSTEAD OF THE OFFSITE CATCH BASIN. | | | | | | 6. WEIR ELEVATION OF 9.55? NAVD IN THE PROPOSED CONTROL | | | STRUCTURE APPEARS LOW BASED ON THE DRY DETENTION POND | | | ELEVATION OF 10.50? NAVD. | | | | | | 7. PROVIDE CROSS SECTION OF ROAD WIDENING (RIGHT TURN | | | LANE). | | | | | | 8. PROVIDE SPOT GRADES FOR NEW RIGHT TURN LANE AND AT | | | DRIVEWAYS. | | | | | | 9. DRY DETENTION AREA IS NOT DEPICTED ON THE WATER MAIN | | | PROFILE OR FORCE MAIN PROFILE ON SHEET C503.0. | | | | | | 10. 6? WATER MAIN TO THE FIRE HYDRANT LABELED AS 10? | | | WATER MAIN ON THE FORCE MAIN PROFILE. | | | | | | 11. PROVIDE VERTICAL DATUM CONVERSION EQUATION ON THE | | | SURVEY. | | | | | | TRACY WARD, P.E. | | | SENIOR STORMWATER ENGINEER | | | ENGINEERING SERVICES DEPARTMENT | | | [email protected] | | | 561-494-1120 (O) | | | 561-351-0510 (M) |
|
|
| Review Stop |
STORM |
STORMWATER |
| Rev No |
1 |
Status |
F |
Date |
12-10-2020 |
|
|
Cont ID |
|
| Sent By |
tward |
Date |
12-10-2020 |
Time |
12:15 |
Rev Time |
0.00 |
| Received By |
tward |
Date |
12-10-2020 |
Time |
12:23 |
Sent To |
|
|
| Notes |
| 2020-12-10 12:16:08 | THIS IS A CONCEPTUAL LEVEL REVIEW. CONSTRUCTION LEVEL | | | DETAILS, DESIGN CALCULATIONS AND THE POLLUTION | | | PREVENTION PLAN WILL BE REVIEWED AS PART OF THE | | | ENGINEERING DEVELOPMENT APPROVAL AND BUILDING PERMIT | | | APPLICATION PROCESSES. | | | | | | THE FOLLOWING COMMENTS MUST BE ADDRESSED PRIOR TO SITE | | | PLAN APPROVAL: | | | | | | 1. THE CITY'S OFFICIAL VERTICAL DATUM IS NGVD1929. THE | | | SURVEY USES NAVD1988. THE CITY HAS ALLOWED NAVD1988 | | | PROVIDED THE CONVERSION BETWEEN NAVD1988 AND NGVD1929 | | | IS LISTED. LABEL THE VERTICAL DATUM AND CONVERSION | | | EQUATION ON SHEET C101.0 | | | | | | 2. CONSIDER REDUCING THE PARKING STALL DEPTH AND | | | PROVIDING 2' PERVIOUS OVERHANG FOR THE PARKING SPACES | | | FACING THE NORTHEAST SIDE OF THE BRANDSMART BUILDING. | | | | | | 3. WHAT IS THE ELEVATION OF THE EXISTING LINING UNDER | | | THE DRY DETENTION AREA? | | | | | | 4. HOW WILL THE LINER UNDER THE DRY DETENTION AREA | | | WHERE THE FUEL STATION IS PROPOSED BE ADJUSTED? | | | | | | 5. DRAINAGE EASEMENTS WILL BE NEEDED FOR EACH PROPERTY | | | TO DRAIN TO THE DRY DETENTION AREA AND TO DRAIN TO THE | | | CONTROL STRUCTURE AND DISCHARGE OFFSITE. | | | | | | 6. SITE MAY CONTAIN SOIL CONTAMINATION FROM PAST USE AS | | | A GOLF COURSE. | | | | | | 7. STORMWATER MANAGEMENT SYSTEM TO BE DESIGNED TO MEET | | | SFWMD ERP CRITERIA. | | | | | | 8. INDICATE IF THE BEST BUY PARCEL DRAINAGE SYSTEM | | | DRAINS ONTO THE SITE. | | | | | | 9. CORRECT THE PLAN SHEET REFERENCE FOR SECTION C-C ON | | | SHEET C404.0. | | | | | | 10. PROVIDE ADA CURB RAMPS MEETING CURRENT ADA CRITERIA | | | FOR ALL SIDEWALK CONNECTIONS TO DRIVEWAYS. | | | | | | 11. PROVIDE TYPICAL SECTION BETWEEN EDGE OF PAVEMENT OF | | | EXECUTIVE CENTER DRIVE AND FACE OF BJ'S BUILDING | | | SHOWING DIMENSIONS AND GROUND SLOPES. | | | | | | 12. PROVIDE TYPICAL SECTION BETWEEN I-95 RIGHT OF WAY | | | AND FACE OF BJ'S BUILDING SHOWING DIMENSIONS OF | | | PARKING/DRIVE AISLES, SIDEWALKS, LANDSCAPE ISLANDS, | | | ETC. AND GROUND SLOPES. | | | | | | | | | THE FOLLOWING COMMENTS MUST BE ADDRESSED PRIOR TO | | | ISSUANCE OF CONSTRUCTION AUTHORIZATION INCLUDING | | | BUILDING PERMITS AND ENGINEERING DEVELOPMENT APPROVAL. | | | | | | 1. AN ENGINEERING DEVELOPMENT APPROVAL APPLICATION MAY | | | BE REQUIRED FROM THE ENGINEERING SERVICES DEPARTMENT. | | | | | | 2. EROSION CONTROL PLAN AND DETAILS TO BE SUBMITTED | | | WITH THE ENGINEERING PERMIT APPLICATION. | | | | | | 3. PROVIDE A COPY OF THE SFWMD ERP MODIFICATION AND | | | DRAINAGE CALCULATIONS PRIOR TO STARTING CONSTRUCTION. | | | | | | TRACY WARD, PE | | | SENIOR STORMWATER ENGINEER | | | ENGINEERING SERVICES DEPARTMENT | | | 561-494-1120 (O) | | | 561-351-0510 (M) | | | [email protected] | | | |
|
|
| Review Stop |
SURVEY |
SURVEYING |
| Rev No |
4 |
Status |
P |
Date |
07-20-2021 |
|
|
Cont ID |
|
| Sent By |
vnoel |
Date |
07-20-2021 |
Time |
07:12 |
Rev Time |
0.00 |
| Received By |
vnoel |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2021-07-20 07:14:46 | CONDITIONS OF APPROVAL: | | | | | | PRIOR TO BUILDING PERMIT, NEED SKETCH AND LEGAL FOR | | | PROPOSED DRAINAGE EASEMENT. |
|
|
| Review Stop |
SURVEY |
SURVEYING |
| Rev No |
3 |
Status |
F |
Date |
06-23-2021 |
|
|
Cont ID |
|
| Sent By |
vnoel |
Date |
06-23-2021 |
Time |
08:55 |
Rev Time |
0.00 |
| Received By |
vnoel |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2021-06-23 08:58:05 | 1. SKETCH AND LEGAL DESCRIPTION IS REQUIRED FOR THAT | | | PORTION OF NEW DRAINAGE EASEMENT THAT FALLS WITHIN THE | | | BJ'S PROPERTY. | | | 2. IT HAS BEEN DETERMINED AFTER DISCUSSION WITH LAW | | | DEPT. THAT A SIGN-OFF FROM BEST BUY WILL NOT BE | | | REQUIRED. |
|
|
| Review Stop |
SURVEY |
SURVEYING |
| Rev No |
2 |
Status |
P |
Date |
03-15-2021 |
|
|
Cont ID |
|
| Sent By |
vnoel |
Date |
03-15-2021 |
Time |
08:59 |
Rev Time |
0.00 |
| Received By |
vnoel |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2021-03-15 09:03:46 | PASSED WITH CONDITIONS: | | | | | | 1. REPLAT PRIOR TO ANY C.O. | | | 2. REVIEW OF CROSS ACCESS, DRAINAGE, ETC. AGREEMENT. |
|
|
| Review Stop |
SURVEY |
SURVEYING |
| Rev No |
1 |
Status |
F |
Date |
12-07-2020 |
|
|
Cont ID |
|
| Sent By |
vnoel |
Date |
12-07-2020 |
Time |
08:26 |
Rev Time |
|
| Received By |
vnoel |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2020-12-07 08:53:07 | 1. NO SURVEY PROVIDED. | | | 2. IT APPEARS THAT THE EXISTING CANAL ALONG THE NORTH | | | PROPERTY LINE IS TO BE FILLED IN.THERE MAY BE DRAINAGE | | | FROM PROPERTIES ON THE NORTH. SHOW AND LABEL ALL | | | EXISTING DRAINAGE AND UTILITY EASEMENTS. | | | 3. REPLAT WILL BE REQUIRED. | | | 4. CROSS ACCESS, UTILITY, DRAINAGE AND PARKING | | | AGREEMENT WILL BE REQUIRED. |
|
|
| Review Stop |
TRAFFIC |
TRAFFIC ENGINEERING |
| Rev No |
5 |
Status |
P |
Date |
07-15-2021 |
|
|
Cont ID |
|
| Sent By |
|
Date |
07-14-2021 |
Time |
|
Rev Time |
0.00 |
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2021-07-14 19:22:42 | APPROVED WITH THE FOLLOWING CONDITION: | | | PRIOR TO ISSUANCE OF CO, THE APPLICANT WILL USE BEST | | | EFFORTS TO WORK WITH PALM BEACH COUNTY TO IMPLEMENT | | | RESTRIPING ON THE NORTHBOUND APPROACH (SOUTH LEG) OF | | | THE INTERSECTION OF PALM BEACH LAKES BOULEVARD & | | | EXECUTIVE CENTER DRIVE TO ALLOW FOR: 2 LEFT TURN LANES | | | + 1 SHARED THROUGH/RIGHT LANE AND THE ASSOCIATED SIGNAL | | | MODIFICATIONS THAT WOULD BE REQUIRED TO ACCOMMODATE | | | THIS RESTRIPING. IF, HOWEVER, THE COUNTY ULTIMATELY | | | DETERMINES THAT THE ASSOCIATED SIGNAL MODIFICATIONS | | | CANNOT BE IMPLEMENTED WHILE UTILIZING THE EXISTING | | | CONCRETE STRAIN POLES AT THE INTERSECTION, THIS | | | IMPROVEMENT WILL NOT BE REQUIRED. INSTEAD, THE | | | APPLICANT WILL PROVIDE STRIPING TO MAXIMIZE THE | | | NORTHBOUND LEFT TURN STORAGE LENGTH TO THE EXTENT | | | PRACTICAL AND CONTRIBUTE $150,000 TOWARDSA CITY | | | DESIGNATED TRANSPORTATION FUND. | | | | | | TRAFFIC COMMENTS: | | | 1. SATISFIED. PER TPS RECOMMENDATION, IMPROVE NB | | | LEFT-TURN QUEUE CAPACITY ALONG EXECUTIVE CENTER DR AT | | | THE PALM BEACH LAKES BLVD INTERSECTION. UPDATED TRAFFIC | | | ANALYSIS WAS NOT PROVIDED IN THE LATEST RESUBMISSION. | | | THE PARKING ANALYSIS DOES NOT ADDRESS THIS COMMENT. | | | 2. SATISFIED. UNLESS THE COUNTY APPROVES AND AGREES TO | | | IMPLEMENT THE OPTIMIZED SIGNAL TIMING AT THE EXECUTIVE | | | DR AND PALM BEACH LAKES BLVD INTERSECTION AS PRESENTED | | | IN THE TRAFFIC STUDY, A LANE RECONFIGURATION OF THE NB | | | APPROACH IS NECESSARY. SPECIFICALLY: CONVERT THE | | | EXISTING 1 LEFT-TURN LANE, 1 THROUGH LANE, 1 RIGHT-TURN | | | LANE TO 2 LEFT-TURN LANES AND 1 THROUGH/RIGHT LANE. | | | 3. SATISFIED. PER TPS RECOMMENDATION, CONSTRUCT | | | RIGHT-TURN DECELERATION LANES AT DRIVEWAY #2 AND #3. | | | PROVIDE PROPER LEFT-TURN CHANNELIZATION TO DRIVEWAY #2 | | | AND #3 BY MEANS OF EITHER STRIPING OR MID-BLOCK | | | ISLANDS. UPDATED TRAFFIC ANALYSIS WAS NOT PROVIDED IN | | | THE LATEST RESUBMISSION. THE PARKING ANALYSIS DOES NOT | | | ADDRESS THIS COMMENT. | | | 4. SATISFIED. PROVIDE AUTOTURN ANALYSIS FOR GARBAGE AND | | | LARGE DELIVERY TRUCK OPERATIONS WITHIN THE FACILITY | | | A. THE WB-67 ANALYSIS SHOWS AN ENCROACHMENT WITH THE | | | LEFT SIDE CURB IN THE SOUTH-EAST PORTION OF THE LOT | | | WHILE TURNING LEFT TOWARDS THE EXIT DRIVEWAY | | | B. GARBAGE TRUCK ANALYSIS SEEMS MISSING | | | 5. SATISFIED. PERTAINING THE PARKING STUDY. PROVIDE | | | PARKING DEMAND VALUES BASED ON ITE PARKING GENERATION | | | MANUAL 5TH EDITION AND COMPARE THEM WITH THE STUDY | | | ESTIMATE. PLEASE ELABORATE AND JUSTIFY THE RESULTS. | | | | | | SITE COMMENTS: | | | 6. SATISFIED. EXTEND THE WIDER SIDEWALK CONFIGURATION | | | ALONG THE PROPERTY FRONTAGE NORTH OF DRIVEWAY #2. | | | PLEASE PROVIDE PLAN SET NAME/NUMBER SHOWCASING SIDEWALK | | | DIMENSIONS | | | 7. SATISFIED. CONSIDER IMPLEMENTING A MULTIMODAL PATH | | | ALONG SITE FRONTAGE OR CONFIGURE EXECUTIVE CENTER DR | | | ROAD GEOMETRY TO MIMIC THE PORTION SOUTH OF CONGRESS | | | AVE. PLEASE PROVIDE PLAN SET NAME/NUMBER SHOWCASING | | | SIDEWALK DIMENSIONS ALONG PROPERTY FRONTAGE. PROVIDE | | | PROPOSED SIDEWALK EXACT WIDTH DIMENSIONS IN THE COMMENT | | | RESPONSE. | | | | | | VALERIO ORICCHIO | | | CITY TRANSPORTATION ENGINEER | | | 561-494-1092 | | | [email protected] | | | |
|
|
| Review Stop |
TRAFFIC |
TRAFFIC ENGINEERING |
| Rev No |
4 |
Status |
F |
Date |
07-06-2021 |
|
|
Cont ID |
|
| Sent By |
|
Date |
07-06-2021 |
Time |
|
Rev Time |
0.00 |
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
TRAFFIC |
TRAFFIC ENGINEERING |
| Rev No |
3 |
Status |
F |
Date |
06-10-2021 |
|
|
Cont ID |
|
| Sent By |
|
Date |
06-10-2021 |
Time |
|
Rev Time |
0.00 |
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2021-06-10 01:36:39 | TRAFFIC COMMENTS: | | | 1. PARTIALLY SATISFIED. PER TPS RECOMMENDATION, IMPROVE | | | NB LEFT-TURN QUEUE CAPACITY ALONG EXECUTIVE CENTER DR | | | AT THE PALM BEACH LAKES BLVD INTERSECTION. UPDATED | | | TRAFFIC ANALYSIS WAS NOT PROVIDED IN THE LATEST | | | RESUBMISSION. THE PARKING ANALYSIS DOES NOT ADDRESS | | | THIS COMMENT. | | | 2. UNLESS THE COUNTY APPROVES AND AGREES TO IMPLEMENT | | | THE OPTIMIZED SIGNAL TIMING AT THE EXECUTIVE DR AND | | | PALM BEACH LAKES BLVD INTERSECTION AS PRESENTED IN THE | | | TRAFFIC STUDY, A LANE RECONFIGURATION OF THE NB | | | APPROACH IS NECESSARY. SPECIFICALLY: CONVERT THE | | | EXISTING 1 LEFT-TURN LANE, 1 THROUGH LANE, 1 RIGHT-TURN | | | LANE TO 2 LEFT-TURN LANES AND 1 THROUGH/RIGHT LANE. | | | 3. SATISFIED. PER TPS RECOMMENDATION, CONSTRUCT | | | RIGHT-TURN DECELERATION LANES AT DRIVEWAY #2 AND #3. | | | PROVIDE PROPER LEFT-TURN CHANNELIZATION TO DRIVEWAY #2 | | | AND #3 BY MEANS OF EITHER STRIPING OR MID-BLOCK | | | ISLANDS. UPDATED TRAFFIC ANALYSIS WAS NOT PROVIDED IN | | | THE LATEST RESUBMISSION. THE PARKING ANALYSIS DOES NOT | | | ADDRESS THIS COMMENT. | | | 4. SATISFIED. PROVIDE AUTOTURN ANALYSIS FOR GARBAGE AND | | | LARGE DELIVERY TRUCK OPERATIONS WITHIN THE FACILITY | | | A. THE WB-67 ANALYSIS SHOWS AN ENCROACHMENT WITH THE | | | LEFT SIDE CURB IN THE SOUTH-EAST PORTION OF THE LOT | | | WHILE TURNING LEFT TOWARDS THE EXIT DRIVEWAY | | | B. GARBAGE TRUCK ANALYSIS SEEMS MISSING | | | 5. SATISFIED. PERTAINING THE PARKING STUDY. PROVIDE | | | PARKING DEMAND VALUES BASED ON ITE PARKING GENERATION | | | MANUAL 5TH EDITION AND COMPARE THEM WITH THE STUDY | | | ESTIMATE. PLEASE ELABORATE AND JUSTIFY THE RESULTS. | | | SITE COMMENTS: | | | 6. SATISFIED. EXTEND THE WIDER SIDEWALK CONFIGURATION | | | ALONG THE PROPERTY FRONTAGE NORTH OF DRIVEWAY #2. | | | PLEASE PROVIDE PLAN SET NAME/NUMBER SHOWCASING SIDEWALK | | | DIMENSIONS | | | 7. SATISFIED. CONSIDER IMPLEMENTING A MULTIMODAL PATH | | | ALONG SITE FRONTAGE OR CONFIGURE EXECUTIVE CENTER DR | | | ROAD GEOMETRY TO MIMIC THE PORTION SOUTH OF CONGRESS | | | AVE. PLEASE PROVIDE PLAN SET NAME/NUMBER SHOWCASING | | | SIDEWALK DIMENSIONS ALONG PROPERTY FRONTAGE. PROVIDE | | | PROPOSED SIDEWALK EXACT WIDTH DIMENSIONS IN THE COMMENT | | | RESPONSE. | | | | | | VALERIO ORICCHIO | | | CITY TRANSPORTATION ENGINEER | | | 561-494-1092 | | | [email protected] | | | | | | | | | |
|
|
| Review Stop |
TRAFFIC |
TRAFFIC ENGINEERING |
| Rev No |
2 |
Status |
F |
Date |
03-29-2021 |
|
|
Cont ID |
|
| Sent By |
|
Date |
03-29-2021 |
Time |
|
Rev Time |
0.00 |
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2021-03-29 13:47:38 | TRAFFIC COMMENTS: | | | 1. PER TPS RECOMMENDATION, IMPROVE NB LEFT-TURN QUEUE | | | CAPACITY ALONG EXECUTIVE CENTER DR AT THE PALM BEACH | | | LAKES BLVD INTERSECTION. UPDATED TRAFFIC ANALYSIS WAS | | | NOT PROVIDED IN THE LATEST RESUBMISSION. THE PARKING | | | ANALYSIS DOES NOT ADDRESS THIS COMMENT. | | | 2. PER TPS RECOMMENDATION, CONSTRUCT RIGHT-TURN | | | DECELERATION LANES AT DRIVEWAY #2 AND #3. PROVIDE | | | PROPER LEFT-TURN CHANNELIZATION TO DRIVEWAY #2 AND #3 | | | BY MEANS OF EITHER STRIPING OR MID-BLOCK ISLANDS. | | | UPDATED TRAFFIC ANALYSIS WAS NOT PROVIDED IN THE LATEST | | | RESUBMISSION. THE PARKING ANALYSIS DOES NOT ADDRESS | | | THIS COMMENT. | | | 3. PROVIDE AUTOTURN ANALYSIS FOR GARBAGE AND LARGE | | | DELIVERY TRUCK OPERATIONS WITHIN THE FACILITY | | | 3A. THE WB-67 ANALYSIS SHOWS AN ENCROACHMENT WITH THE | | | LEFT SIDE CURB IN THE SOUTH-EAST PORTION OF THE LOT | | | WHILE TURNING LEFT TOWARDS THE EXIT DRIVEWAY | | | 3B. GARBAGE TRUCK ANALYSIS SEEMS MISSING | | | 4. PERTAINING THE PARKING STUDY. PROVIDE PARKING DEMAND | | | VALUES BASED ON ITE PARKING GENERATION MANUAL 5TH | | | EDITION AND COMPARE THEM WITH THE STUDY ESTIMATE. | | | PLEASE ELABORATE AND JUSTIFY THE RESULTS. | | | | | | SITE COMMENTS: | | | 5. EXTEND THE WIDER SIDEWALK CONFIGURATION ALONG THE | | | PROPERTY FRONTAGE NORTH OF DRIVEWAY #2. PLEASE PROVIDE | | | PLAN SET NAME/NUMBER SHOWCASING SIDEWALK DIMENSIONS | | | 6. CONSIDER IMPLEMENTING A MULTIMODAL PATH ALONG SITE | | | FRONTAGE OR CONFIGURE EXECUTIVE CENTER DR ROAD GEOMETRY | | | TO MIMIC THE PORTION SOUTH OF CONGRESS AVE. PLEASE | | | PROVIDE PLAN SET NAME/NUMBER SHOWCASING SIDEWALK | | | DIMENSIONS ALONG PROPERTY FRONTAGE. PROVIDE PROPOSED | | | SIDEWALK EXACT WIDTH DIMENSIONS IN THE COMMENT | | | RESPONSE. | | | | | | VALERIO ORICCHIO | | | CITY TRANSPORTATION ENGINEER | | | 561-494-1092 | | | [email protected] | | | | | | | | | |
|
|
| Review Stop |
TRAFFIC |
TRAFFIC ENGINEERING |
| Rev No |
1 |
Status |
F |
Date |
12-10-2020 |
|
|
Cont ID |
|
| Sent By |
|
Date |
12-10-2020 |
Time |
|
Rev Time |
|
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2020-12-10 13:06:23 | TRAFFIC COMMENTS: | | | 1. PER TPS RECOMMENDATION, IMPROVE NB LEFT-TURN QUEUE | | | CAPACITY ALONG EXECUTIVE CENTER DR AT THE PALM BEACH | | | LAKES BLVD INTERSECTION | | | 2. PER TPS RECOMMENDATION, CONSTRUCT RIGHT-TURN | | | DECELERATION LANES AT DRIVEWAY #2 AND #3. PROVIDE | | | PROPER LEFT-TURN CHANNELIZATION TO DRIVEWAY #2 AND #3 | | | BY MEANS OF EITHER STRIPING OR MID-BLOCK ISLANDS | | | 3. PROVIDE AUTOTURN ANALYSIS FOR GARBAGE AND LARGE | | | DELIVERY TRUCK OPERATIONS WITHIN THE FACILITY | | | | | | SITE COMMENTS: | | | 4. EXTEND THE EXISTING WIDER SIDEWALK CONFIGURATION | | | ALONG THE PROPERTY FRONTAGE NORTH OF DRIVEWAY #2 | | | 5. CONSIDER IMPLEMENTING A MULTIMODAL PATH ALONG SITE | | | FRONTAGE OR CONFIGURE EXECUTIVE CENTER DR ROAD GEOMETRY | | | TO MIMIC THE PORTION SOUTH OF CONGRESS AVE | | | | | | VALERIO ORICCHIO | | | CITY TRANSPORTATION ENGINEER | | | 561-494-1092 | | | [email protected] | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
5 |
Status |
P |
Date |
07-19-2021 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
07-19-2021 |
Time |
10:52 |
Rev Time |
3.00 |
| Received By |
eschneid |
Date |
07-16-2021 |
Time |
09:43 |
Sent To |
|
|
| Notes |
| 2021-07-19 10:51:29 | THE APPLICATION IS SUFFICIENT FOR PLANNING BOARD WITH | | | THE FOLLOWING CONDITIONS/DEVELOPMENT REGULATIONS (FINAL | | | WORDING WILL BE CONTAINED IN THE PLANNING BOARD | | | REPORT). NOTE: ADDITIONAL CONDITIONS/DEVELOPMENT | | | REGULATIONS MAY BE REQUIRED BASED ON COMMENTS FROM | | | OTHER REVIEWERS OR DURING THE DRAFTING OF THE REPORTS | | | OR LEGISLATION. | | | | | | WAIVER UPDATE | | | | | | ACCESS POINTS - WHILE THIS WAIVER IS LISTED ON THE | | | PLANS, THE RESPONSE INCORRECTLY STATES THAT IT IS NOT | | | REQUIRED. THE ACCESS POINTS ARE BASED ON A DEVELOPMENT, | | | NOT THE INDIVIDUAL PARCELS WITHIN A DEVELOPMENT; | | | THEREFORE, THE WAIVER IS REQUIRED FOR THE THREE | | | PROPOSED ACCESS POINTS. | | | | | | LANDSCAPE BUFFER - THE TITLE OF THE CODE SECTION | | | (97-443.B.4) AND CITED ON THE WAIVER TABLE ON SHEET | | | C101.0 IS CUT SHORT AND THUS IMPLIES THAT IT IS NOT AT | | | THE LOCATION WHERE THE WAIVER IS ACTUALLY FOR SINCE | | | THIS IS NOT A BUFFER ADJACENT TO A THOROUGHFARE.. | | | CONDITION: PRIOR TO SCHEDULING THE HEARING FOR CITY | | | COMMISSION, THIS LINE NEEDS TO BE CORRECTED TO STAGE | | | "BUFFERING OF NONRESIDENTIAL USES ADJACENT TO A | | | NONRESIDENTIAL ZONING DISTRICT" AND THE REVISED SHEET | | | PROVIDED TO THE PLANNING DIVISION. | | | | | | SITE PLAN | | | | | | CONDITION: PRIOR TO SCHEDULING THE CASE BEFORE THE CITY | | | COMMISSION, ALL THE MISALIGNED DIMENSION TAGS ON SHEET | | | C102.0 MUST BE CORRECTED. ***** NOT ALL WERE CORRECTED | | | FOR CURRENT RESUBMITTAL. | | | | | | CONDITION: PRIOR TO SCHEDULING THE CASE BEFORE THE CITY | | | COMMISSION, THE PLANS NEED TO BE UPDATED TO SHOW EITHER | | | BENCHES, A SEAT WALL(S), OR OTHER TYPE OF SEATING AT | | | THE BIOSWALE OVERLOOKS. THE SEATING SHALL BE DESIGNED | | | TO COMPLY WITH CRIME PREVENTION THROUGH ENVIRONMENTAL | | | DESIGN (CEPTD) STANDARDS. | | | | | | CONDITION: PRIOR TO SCHEDULING THE HEARING BEFORE THE | | | CITY COMMISSION, PROVIDE A SKETCH AND LEGAL DESCRIPTION | | | FOR THAT PORTION OF THE NEW DRAINAGE EASEMENT WITHIN | | | THE BRANDSMARRT CPD PROPERTY SO THAT THE CITY CAN | | | PREPARE THE AGREEMENT TO TERMINATE AND REDEDICATE THE | | | DRAINAGE EASEMENT TO REFLECT THE ACTUAL PIPE LOCATION. | | | | | | DEVELOPMENT REGULATIONS FOR CPD | | | | | | DEVELOPMENT REGULATION: PRIOR TO ANY CONSTRUCTION, THE | | | FPL MUST PROVIDE A RELEASE OF THE EASEMENTS WHICH | | | CONFLICT WITH THE PROPOSED BJS BUILDING. | | | | | | DEVELOPMENT REGULATION: ALL TRANSFORMERS MUST BE | | | SCREENED FROM VIEW BY THE PUBLIC. | | | | | | DEVELOPMENT REGULATION: ALL ROOFTOP MECHANICAL | | | EQUIPMENT MUST BE SCREENED TO THE FULL HEIGHT OF THE | | | EQUIPMENT. | | | | | | DEVELOPMENT REGULATION: IN THE EVENT THAT THE PARCEL IS | | | SUBDIVIDED, PRIOR TO ISSUANCE OF CO FOR THE BJS | | | BUILDING, CROSS UTILITY AGREEMENTS/EASEMENTS WILL BE | | | REQUIRED FOR THE BRANDSMART CPD. | | | | | | DEVELOPMENT REGULATION: IN THE EVENT THAT THE PARCEL IS | | | SUBDIVIDED, PRIOR TO ISSUANCE OF CO FOR THE BJS | | | BUILDING, A PLAT FOR THE PROPERTY MUST BE APPROVED BY | | | THE CITY AND RECORDED BY THE APPLICANT. | | | | | | DEVELOPMENT REGULATION (DRAFT): PRIOR TO ISSUANCE OF | | | CO, THE APPLICANT WILL USE BEST EFFORTS TO WORK WITH | | | PALM BEACH COUNTY TO IMPLEMENT RESTRIPING ON THE | | | NORTHBOUND APPROACH (SOUTH LEG) OF THE INTERSECTION OF | | | PALM BEACH LAKES BOULEVARD & EXECUTIVE CENTER DRIVE TO | | | ALLOW FOR: 2 LEFT TURN LANES + 1 SHARED THROUGH/RIGHT | | | LANE AND THE ASSOCIATED SIGNAL MODIFICATIONS THAT WOULD | | | BE REQUIRED TO ACCOMMODATE THIS RESTRIPING. IF, | | | HOWEVER, THE COUNTY ULTIMATELY DETERMINES THAT THE | | | ASSOCIATED SIGNAL MODIFICATIONS CANNOT BE IMPLEMENTED | | | WHILE UTILIZING THE EXISTING CONCRETE STRAIN POLES AT | | | THE INTERSECTION, THIS IMPROVEMENT WILL NOT BE | | | REQUIRED. INSTEAD, THE APPLICANT WILL PROVIDE STRIPING | | | TO MAXIMIZE THE NORTHBOUND LEFT TURN STORAGE LENGTH TO | | | THE EXTENT PRACTICAL AND CONTRIBUTE $150,000 TOWARDS | | | THE CITY'S TROLLEY FUND. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
4 |
Status |
F |
Date |
06-28-2021 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
06-28-2021 |
Time |
14:40 |
Rev Time |
5.00 |
| Received By |
eschneid |
Date |
06-25-2021 |
Time |
09:12 |
Sent To |
|
|
| Notes |
| 2021-06-28 14:41:49 | CASE NO. PB1060MM - JUNE 28, 2021 REVIEW | | | BJS @ BRANDSMART | | | 751 WEST EXECUTIVE CENTER DRIVE | | | | | | - CONTACT ERIC SCHNEIDER @ (561) 822-1446, | | | [email protected] | | | | | | - PLEASE PROVIDE RESPONSES TO REVIEW COMMENTS IN | | | WRITTEN FORMAT. | | | | | | - WHEN RESUBMITTING, PLEASE PROVIDE A MINIMUM OF FOUR | | | (4) PAPER COPIES AND AN ELECTRONIC COPY IN .PNG FORMAT | | | OF ALL PLANS. PLEASE NOTE THAT CHANGES ON THE | | | RESUBMITTED PLANS OR THE SUBMITTAL OF INFORMATION/PLANS | | | TO ADDRESS THE COMMENTS MAY RESULT IN ADDITIONAL | | | COMMENTS. | | | | | | - THE PPRC COMMENTS SHALL BE SUFFICIENTLY ADDRESSED AND | | | SUBMITTED TO THE PLANNING DIVISION TO BE ELIGIBLE TO BE | | | SCHEDULED FOR THE NEXT AVAILABLE PLANNING BOARD | | | MEETING. | | | | | | - PLEASE NOTE THAT IF THE PLANNING DIVISION HAS NOT | | | RECEIVED A RESPONSE TO THE COMMENTS WITHIN 60 DAYS FROM | | | THE DATE OF THESE COMMENTS (BY AUGUST 28, 2021), THE | | | PLANNING DIVISION MAY NOTIFY THE APPLICANT THAT THE | | | CASE IS CONSIDERED WITHDRAWN. ANY FURTHER ACTION SHALL | | | REQUIRE A NEW DEVELOPMENT APPLICATION. | | | | | | - PLEASE NOTE THAT YOU WILL BE PERMITTED ONE (1) | | | RESUBMITTAL AT NO ADDITIONAL COST. IF PREVIOUSLY ISSUED | | | COMMENTS CONTINUE TO NOT BE SUFFICIENTLY ADDRESSED, THE | | | APPLICANT WILL BE ASSESSED A RESUBMITTAL FEE. SUCH FEE | | | WILL BE 20% OF THE ORIGINAL APPLICATION FEE ($600). | | | | | | - PUBLIC HEARING NOTIFICATION SIGNAGE SHALL BE POSTED | | | IN ACCORDANCE WITH THE REQUIREMENTS OF SECTION | | | 94-39(I)(5) OF THE ZONING AND LAND DEVELOPMENT | | | REGULATIONS. | | | | | | 1) THE JUSTIFICATION STATEMENT REMOVED REFERENCE TO | | | SEATING AT THE BIOSWALE OVERLOOKS. SEATING NEEDS TO BE | | | PROVIDED AT THESE LOCATIONS (THIS CAN BE USED BY NOT | | | ONLY THE PUBLIC, BUT ALSO EMPLOYEES EATING LUNCH). | | | | | | WAIVERS | | | | | | 2) STAFF HAS IDENTIFIED ADDITIONAL WAIVERS THAT ARE | | | REQUIRED: | | | | | | A. THE AREA WHERE THE DRAINAGE EASEMENT IS DOES NOT | | | PROVIDE THE BUFFER TREES AT THE REQUIRED 30-FOOT ON | | | CENTER. STAFF DOES NOT OBJECT TO THIS WAIVER REQUEST. | | | | | | B. THE SITE EXCEEDS THE NUMBER OF ACCESS POINTS | | | PERMITTED ONTO A RIGHT-OF-WAY. SECTION 94-312.1.A | | | PERMITS ONLY TWO ACCESS POINTS ONTO EXECUTIVE CENTER | | | DRIVE. BASED ON THE SITE DESIGN, STAFF DOES NOT OBJECT | | | TO A WAIVER REQUEST FOR THREE ACCESS POINTS. | | | | | | SITE PLAN | | | | | | 3) SHEET C102.0 HAS MISALIGNED DIMENSION TAGS ALONG THE | | | PARKING ROWS ADJACENT TO I-95. THESE NEED TO BE | | | CORRECTLY PLACED. | | | | | | LANDSCAPE PLAN | | | | | | 4) THE EXISTING STORMWATER PIPE FROM BEST BUY TO | | | EXECUTIVE CENTER DRIVE IS NOT SHOWN ON SHEET L-200 BUT | | | NOT ON ENLARGED SHEET L-201. THE PROPOSED REPLACEMENT | | | 12-FOOT WIDE STORMWATER EASEMENT, CENTERED ON THE | | | STORMWATER PIPE, IS NOT SHOWN ON EITHER SHEET. THESE | | | MUST BE SHOWN ON BOTH SHEETS SO THAT PLANNING CAN | | | VERIFY THAT THERE ARE NO TREES PLACED WITHIN THE | | | STORMWATER EASEMENT AND THAT TREES IN PROXIMITY TO THE | | | EASEMENT HAVE THE PROPER ROOT BARRIER. A WAIVER IS | | | REQUIRED FOR THE TREES THAT WILL NOT BE INSTALLED AND | | | WITHOUT THE EASEMENT ACCURATELY SHOWN ON THE PLAN, | | | STAFF CANNOT ENUMERATE THE SPECIFIC WAIVER REQUIRED. | | | | | | 5) THERE ARE NUMEROUS CONFLICTS WHERE REQUIRED TREES | | | ARE EITHER CLOSE TO OR ON TOP OF THE VARIOUS UTILITY | | | INFRASTRUCTURE ON THE SITE, WHICH IS NOT PERMITTED. | | | STAFF WILL BE PROVIDING A MARKED-UP PLAN WITH THESE | | | LOCATIONS UNDER SEPARATE COVER. | | | | | | 6) THE PARKING ROWS IN THE PARKING FIELD ON THE SOUTH | | | PORTION OF THE SITE DO NOT COMPLY WITH THE DIVIDER | | | MEDIAN REQUIREMENTS. THIS COMMENT WAS PREVIOUSLY | | | INCLUDED AND DISCUSSED WITH RAY CARANCI, SENIOR | | | LANDSCAPE PLANNER, AND NOT ADDRESSED. STAFF WILL BE | | | PROVIDING A MARKED-UP PLAN WITH ADDITIONAL INFORMATION | | | UNDER SEPARATE COVER. THIS MAY REQUIRE AN UPDATE TO THE | | | PARKING TABLE. | | | | | | 7) THERE ARE TERMINAL ISLANDS THAT DO NOT HAVE THE | | | REQUIRED TREES. STAFF WILL BE PROVIDING A MARKED-UP | | | PLAN WITH THESE LOCATIONS UNDER SEPARATE COVER. | | | | | | 8) THE REQUIRED AND PROVIDED TREE COUNTS ON THE WPB | | | LANDSCAPE LEGEND CONTAIN ERRORS. THE CITY REQUIRES THAT | | | ANY PARTIAL TREE IS ROUNDED UP. THIS REQUIRED TREES ON | | | THE EAST, WEST AND EXECUTIVE CENTER DRIVE FRONTAGES | | | EACH REQUIRE ONE ADDITIONAL TREE. STAFF HAS COUNTED THE | | | TREES ALONG EACH OF THESE BUFFERS AND THERE ARE AN | | | ADEQUATE NUMBER OF TREES (NOT TRESS AS MISSPELLED ON | | | THE TABLE) PROVIDED, AND ON AT LEAST TWO OF THE BUFFERS | | | THE NUMBER PROVIDED IS UNDER COUNTED COMPARED WITH WHAT | | | IS PROVIDED. | | | | | | CONDITION - PRIOR TO ANY CONSTRUCTION, THE FPL MUST | | | PROVIDE A RELEASE OF THE EASEMENTS WHICH CONFLICT WITH | | | THE PROPOSED BJS BUILDING. | | | | | | CONDITION - ALL TRANSFORMERS MUST BE SCREENED. | | | | | | CONDITION - ALL ROOFTOP MECHANICAL EQUIPMENT MUST BE | | | SCREENED TO THE FULL HEIGHT OF THE EQUIPMENT. | | | | | | CONDITION - CROSS UTILITY AGREEMENTS/EASEMENTS WILL BE | | | REQUIRED. | | | | | | CONDITION - PRIOR TO CO THE PLAT NEEDS TO BE RECORDED. | | | | | | SITE CIRCULATION | | | | | | PLANNING STAFF HAS REVIEWED THE EASEMENT WITH COVENANTS | | | AND RESTRICTIONS COVERING THE CROSS-ACCESS AREA WITH | | | THE CITY SURVEYOR AND ATTORNEY'S OFFICE IN RELATION TO | | | THE LATEST SUBMITTED SITE PLAN AND VERIFIED THAT THE | | | PROPOSED NORTHERN ACCESS DRIVE FALLS WITHIN THE ACCESS | | | EASEMENT LIMITS. THEREFORE, THERE IS NO CONFLICT | | | BETWEEN THIS PROJECT AND THE EASEMENT IN FAVOR OF BEST | | | BUY. STAFF RECOMMENDS THAT YOU STILL PURSUE ABANDONING | | | THE EASEMENT WITH BEST BUY AS IT DOES NOT APPEAR TO NO | | | LONGER BE NEEDED. | | | | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
F |
Date |
06-01-2021 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
06-01-2021 |
Time |
12:10 |
Rev Time |
5.00 |
| Received By |
eschneid |
Date |
05-28-2021 |
Time |
16:22 |
Sent To |
|
|
| Notes |
| 2021-06-01 12:12:24 | CASE NO. PB1060MM - MAY 31, 2021 REVIEW | | | BJS @ BRANDSMART | | | 751 WEST EXECUTIVE CENTER DRIVE | | | | | | - CONTACT ERIC SCHNEIDER @ (561) 822-1446, | | | [email protected] | | | | | | - PLEASE PROVIDE RESPONSES TO REVIEW COMMENTS IN | | | WRITTEN FORMAT. | | | | | | - WHEN RESUBMITTING, PLEASE PROVIDE A MINIMUM OF FOUR | | | (4) PAPER COPIES AND AN ELECTRONIC COPY IN .PNG FORMAT | | | OF ALL PLANS. PLEASE NOTE THAT CHANGES ON THE | | | RESUBMITTED PLANS OR THE SUBMITTAL OF INFORMATION/PLANS | | | TO ADDRESS THE COMMENTS MAY RESULT IN ADDITIONAL | | | COMMENTS. | | | | | | - THE PPRC COMMENTS SHALL BE SUFFICIENTLY ADDRESSED AND | | | SUBMITTED TO THE PLANNING DIVISION TO BE ELIGIBLE TO BE | | | SCHEDULED A PLANNING BOARD MEETING. | | | | | | - PLEASE NOTE THAT IF THE PLANNING DIVISION HAS NOT | | | RECEIVED A RESPONSE TO THE COMMENTS WITHIN 60 DAYS FROM | | | THE DATE OF THESE COMMENTS (BY AUGUST 1, 2021), THE | | | PLANNING DIVISION MAY NOTIFY THE APPLICANT THAT THE | | | CASE IS CONSIDERED WITHDRAWN. ANY FURTHER ACTION SHALL | | | REQUIRE A NEW DEVELOPMENT APPLICATION. | | | | | | - PLEASE NOTE THAT YOU WILL BE PERMITTED ONE (1) | | | RESUBMITTAL AT NO ADDITIONAL COST. IF PREVIOUSLY ISSUED | | | COMMENTS CONTINUE TO NOT BE SUFFICIENTLY ADDRESSED, THE | | | APPLICANT WILL BE ASSESSED A RESUBMITTAL FEE. SUCH FEE | | | WILL BE 20% OF THE ORIGINAL APPLICATION FEE ($600). | | | | | | - PUBLIC HEARING NOTIFICATION SIGNAGE SHALL BE POSTED | | | IN ACCORDANCE WITH THE REQUIREMENTS OF SECTION | | | 94-39(I)(5) OF THE ZONING AND LAND DEVELOPMENT | | | REGULATIONS. | | | | | | INNOVATIVE FEATURES LISTED IN JUSTIFICATION STATEMENT | | | | | | 1) THE JUSTIFICATION STATEMENT LISTS THAT THE | | | DECORATIVE CONCRETE PATH AND PAVER PLAZA AROUND THE | | | BIOSWALE INCLUDES A SEAT WALL, BENCHES, LIGHTED | | | BOLLARDS. PLEASE PROVIDE DETAILS OF THE PAVER OVERLOOKS | | | AND THE WALKWAY MEETING THIS STATEMENT. THE PLANS DO | | | NOT SHOW ANY SEAT WALL OR BENCHES AT THE OVERLOOKS. | | | SOME SEATING NEEDS TO BE PROVIDED AT THESE LOCATIONS | | | (CAN BE USED BY EMPLOYEES TO EAT LUNCH). ADDITIONALLY, | | | THE PHOTOMETRIC PLAN SHOWS NO DETAILS OF BOLLARD | | | LIGHTING OR BOLLARD LIGHTING LOCATIONS ALONG THE PATH. | | | PLEASE UPDATE THE PLANS ACCORDINGLY. | | | | | | 2) PLEASE PROVIDE THE JUSTIFICATION STATEMENT IN WORD. | | | | | | WAIVERS | | | | | | 3) STAFF HAS REVIEWED THE WAIVERS LISTED IN THE | | | JUSTIFICATION STATEMENT AS WELL AS WHAT STAFF HAS | | | IDENTIFIED BASED ON THE PLANS AND HAS PROVIDED THEM | | | BELOW WITH COMMENTARY. | | | | | | A. WAIVER REQUESTED FOR NUMBER OF ON-SITE PARKING | | | SPACES REQUIRED - THE CITY'S TRAFFIC ENGINEERING | | | COMMENTS POSTED ON MARCH 29, 2021, REQUIRED THE | | | SUBMITTAL OF SUPPLEMENTAL ITE INFORMATION FOR THE | | | PARKING STUDY. PLANNING STAFF IS AWAITING THE TRAFFIC | | | ENGINEERING REVIEW TO FINALIZE IF THE PARKING STUDY | | | REQUIREMENT HAS BEEN MET TO MOVE FORWARD WITH THE | | | PARKING WAIVER. | | | | | | B. INTERIOR LOT LINE BUFFER REQUIREMENTS - THE | | | PERIMETER BUFFER APPEARS TO MEET THE MINIMUM LANDSCAPE | | | BUFFER REQUIREMENTS, AND IN SOME AREA EXCEEDS THE | | | MINIMUM WIDTH. THE AREA ALONG THE NEIGHBORING PARCEL TO | | | THE NORTH WHERE THE EXISTING EASEMENT IS SHOWS | | | COMPLIANT LANDSCAPE; HOWEVER, THIS EASEMENT NEEDS TO BE | | | AMENDED TO PERMIT THE TREES AS SHOWN. A LATER COMMENT | | | ADDRESSES THIS. STAFF DOES NOT OBJECT TO THIS WAIVER | | | REQUEST. | | | | | | C. NUMBER OF SIGNS ON THE BJS - 3 PERMITTED, 6 | | | PROPOSED. MEETS SF ALLOWANCE. THE MORE DESIRABLE AND | | | ATTRACTIVE DEVELOPMENT BASED ON THE PROVISION OF A TRUE | | | BIOSWALE WITH FULL BOARDWALK CAN OFFSET THIS WAIVER | | | REQUEST. STAFF DOES NOT OBJECT TO THIS WAIVER REQUEST. | | | | | | D. SIGNS ON THE SHORT END OF THE FUEL CANOPY EXCEED | | | REQUIRED SIGNAGE SQUARE FOOTAGE ALLOWANCE. THE | | | PERMITTED SIGN SQUARE FOOTAGE IS 4.32 ON EACH SHORT END | | | OF THE CANOPY. THE SIGN PACKAGE SHOWS THESE SIGNS AS | | | 22.1 SQUARE FEET IN AREA. THE PROPOSED SIGNS ARE | | | APPROXIMATELY 5 TIMES LARGER THAN IS PERMITTED. IF BJS | | | WISHES TO HAVE THESE SIGNS, THEN A WAIVER TO THE SIZE | | | OF THE SIGNS IS REQUIRED. NOTE: NO DIMENSIONS FOR THE | | | SIGNS WERE PROVIDED ON THE FUEL STATION ELEVATION. THIS | | | WAIVER IS REQUESTED IN THE RESPONSE COMMENTS BY NOT | | | LISTED AS A WAIVER REQUEST ELSEWHERE (TO INCLUDE IN THE | | | JUSTIFICATION STATEMENT). PLEASE UPDATE IF YOU ARE | | | REQUESTING THIS WAIVER. | | | | | | E. THE DOUBLE ROW OF COMPACT PARKING CONTAINS 11 | | | PARKING SPACES IN A ROW, WHICH IS NOT PERMITTED UNLESS | | | THE STAGGERED INTERIOR PARKING ISLAND PROVISION IS | | | USED. THIS HAS NOT BEEN LISTED AS A WAIVER REQUEST. | | | NOTE: STAFF IS NOT PREPARED TO SUPPORT THIS THIS | | | PROPOSED WAIVER. | | | | | | SUBDIVISION | | | | | | 4) THE SITE REQUIRES A MINOR SUBDIVISION. AS STATED IN | | | THE ORIGINAL COMMENTS FOR THE PROJECT, THE MINOR | | | SUBDIVISION (PLAT REVIEW) REQUIRES THE SUBMITTAL OF A | | | MINOR SUBDIVISION (PLAT) APPLICATION, WHICH WAS NOT | | | SUBMITTED WITH THE REVISED PLAT. | | | | | | PARKING | | | | | | 5) NOT ALL THE COMPACT PARKING SPACES MAY BE LABELED AS | | | EMPLOYEE ONLY. | | | | | | 6) THE THREE WESTERNMOST COMPACT SPACES ON THE NORTH | | | SIDE OF THE BJS BUILDING DO NOT HAVE THE REQUIRED 24 | | | FOOT BACK UP AREA FOR 90-DEGREE PARKING SPACES AND THUS | | | ARE NOT PERMITTED. | | | | | | 7) THE EMPLOYEE PARKING SPACES ADJACENT TO THE | | | 0.34-ACRE DRY DETENTION AREA HAD THE WHEEL STOPS | | | REMOVED AND THE SIGNS MOVED BACK SO THAT THERE IS NOW A | | | TWO-FOOT OVERHANG AREA, WHICH MAKES THESE 18-FOOT-DEEP | | | PARKING SPACES AND NO LONGER COMPACT PARKING SPACES. | | | UPDATE THE PLANS AND THE PARKING TABLE ACCORDINGLY. | | | | | | 8) THE SIGNPOSTS BETWEEN THE FACING TIRE CENTER PARKING | | | SPACES ARE ONE FOOT IN DIAMETER, WHICH ENCROACH INTO | | | THE PARKING SPACES MAKING THE SPACES NO LONGER CODE | | | COMPLIANT AS THEY ARE NO LONGER 18 FEET DEEP. THE SIGN | | | DETAILS WERE NOT UPDATED. | | | | | | 9) THE SIGNPOSTS BETWEEN THE FACING MEMBER WITH INFANT | | | PARKING SPACES ARE ONE FOOT IN DIAMETER, WHICH ENCROACH | | | INTO THE PARKING SPACES MAKING THE SPACES NO LONGER | | | CODE COMPLIANT AS THEY ARE NO LONGER 18 FEET DEEP. THE | | | SIGN DETAILS WERE NOT UPDATED. | | | | | | 10) THE LIGHT POSTS IN THE PARKING ROWS ON THE EASTERN | | | PARKING AREA MUST BE LOCATED IN THE CORNER WHERE THE | | | FOUR SPACES MEET, NOT IN THE MIDDLE AS SHOWN AS THIS | | | RENDERS THE PARKING SPACES NON-COMPLIANT BASED ON THE | | | PARKING SPACE NO LONGER BEING 18 FEET DEEP. ONE LIGHT | | | POLE IS STILL INCORRECTLY SHOWN ON THE PLANS. | | | | | | 11) PARKING PROVIDED - THIS NEEDS TO BE UPDATED BASED | | | ON THE COMMENTS PROVIDED. | | | | | | 12) BICYCLE PARKING | | | | | | A. THANK YOU FOR UPDATING THE PARKING TABLE TO SHOW | | | THAT 39 BICYCLE PARKING SPACES ARE REQUIRED AND THAT | | | YOU PLAN TO INSTALL 40 BICYCLE PARKING SPACES. | | | B. THE PLANS MUST CLEARLY SHOW THE NUMBER OF BICYCLE | | | PARKING SPACES PROVIDED AT EACH LOCATION SO THAT STAFF | | | CAN VERIFY THE TOTAL NUMBER OF SPACES PROVIDED. | | | C. THE CODE COMPLIANT DIMENSIONS OF THE BICYCLE RACK | | | PADS IS REQUIRED TO BE INCLUDED ON THE SITE PLAN. | | | D. THE BICYCLE RACK STYLE DETAILS. WITH DIMENSIONS, IS | | | REQUIRED TO BE SHOWN ON THE DETAIL SHEET. NOTE: THE | | | WAVE STYLE THAT IS SHOWN IS NOT PERMITTED IN THE CITY. | | | E. A BICYCLE PAD DETAIL, WITH DIMENSIONS, IS REQUIRED | | | FOR EACH SET OF BICYCLE RACKS. THE RACK LOCATION ON THE | | | PADS MUST CLEARLY BE SHOWN TO MEET CITY STANDARDS. | | | | | | SITE CIRCULATION | | | | | | 13) THE CARWASH APPLICANT PROVIDED A COPY OF THE | | | EASEMENT WITH COVENANTS AND RESTRICTIONS COVERING THE | | | CROSS-ACCESS AREA. IT INDICATES THAT BEST BUY HAS AN | | | INTEREST IN THE CROSS ACCESS, SPECIFICALLY A DRIVE TO | | | EXECUTIVE CENTER DRIVE. PLEASE PROVIDE VERIFICATION | | | THAT BEST BUY HAS RELEASED THEIR INTEREST IN THE | | | EASEMENT. THE SITE PLAN SHOWS LANDSCAPING OBSTRUCTING | | | BEST BUY FROM UTILIZING THE EASEMENT. PLEASE NOTE THAT | | | REGARDLESS OF WHAT IS STATED IN THE EASEMENT, BEST BUY | | | HAS NO RIGHTS TO THE INSTALLATION OF AN OFF-PREMISE | | | SIGN, WHICH WOULD BE IN VIOLATION OF THE ZONING AND | | | LAND DEVELOPMENT REGULATIONS. NO EVIDENCE THAT BEST BUY | | | NO LONGER HAS RIGHTS OR AN INTEREST IN THE CROSS ACCESS | | | HAS BEEN PROVIDED. | | | | | | LANDSCAPE | | | | | | 14) ALL EXISTING AND PROPOSED UTILITIES AND EASEMENTS | | | MUST BE SHOWN ON THE LANDSCAPE PLAN SO THAT STAFF CAN | | | VERIFY THAT THERE ARE NO CONFLICTS WITH PROPOSED PLANS | | | OR THAT PROPER ROOT BARRIERS ARE PROPOSED. | | | | | | A. THE EXISTING STORMWATER PIPE FROM BEST BUY TO | | | EXECUTIVE CENTER DRIVE IS NOT SHOWN. AS PART OF THE | | | APPROVALS FOR THE TWO NEIGHBORING DEVELOPMENTS, THE | | | STORMWATER EASEMENT IS PLANNED TO BE REDUCED TO 12 FOOT | | | IN WIDTH, CENTERED ON THE STORMWATER PIPE. THE | | | LANDSCAPE PLANS NEED TO SHOW VERIFICATION THAT THE | | | LANDSCAPE IS NOT LOCATED WITHIN THIS FUTURE REDUCED | | | EASEMENT. THE LANDSCAPE IS LOCATED WITHIN THE CURRENT | | | EASEMENT, WHICH WOULD NOT BE PERMITTED. | | | | | | B. THE EXISTING WATER AND SANITARY LINES THAT TRAVERSE | | | THE SITE TO THE EXISTING LIFT STATION ARE NOT SHOWN ON | | | THE LANDSCAPE PLANS AND SHOW POTENTIAL CONFLICTS WITH | | | THE PROPOSED TREES IN THE PARKING DIVIDER ROWS AND | | | ISLANDS. | | | | | | 15) REMOVE THE UTILITY LINES THAT WILL BE NO LONGER | | | EXIST FROM THE LANDSCAPE PLANS. THERE IS AT LEAST ONE | | | WATER LINE AND ONE STORMWATER LINE THAT AT SHOWN BEING | | | REMOVED ON THE CIVIL DEMOLITION PLANS THAT ARE STILL | | | SHOWN ON THE LANDSCAPE PLANS. | | | | | | 16) THERE ARE TWO TERMINAL ISLANDS THAT DO NOT HAVE THE | | | REQUIRED TREES. | | | | | | A. ONE CONTAINS THE PROPOSED SIGN ALONG I95. | | | | | | B. ONE IS NEAR THE LIFT STATION BY THE FUEL PUMP AREA. | | | | | | 17) THE WIDTH OF ALL OF THE TERMINAL ISLAND TREES IN | | | THE SOUTH PARKING AREA WERE NOT PROVIDED. THE PLANS | | | MUST CLEARLY SHOW THAT THESE TERMINAL ISLANDS HAVE THE | | | REQUIRED EIGHT (8) FEET OF WIDTH FOR THE LENGTH OF THE | | | PARKING STALL. | | | | | | CONDITION - PRIOR TO ANY CONSTRUCTION, THE FPL MUST | | | PROVIDE A RELEASE OF THE EASEMENTS WHICH CONFLICT WITH | | | THE PROPOSED BJS BUILDING. | | | | | | CONDITION - ALL TRANSFORMERS MUST BE SCREENED. | | | | | | CONDITION - ALL ROOFTOP MECHANICAL EQUIPMENT MUST BE | | | SCREENED TO THE FULL HEIGHT OF THE EQUIPMENT. | | | | | | CONDITION - CROSS UTILITY AGREEMENTS/EASEMENTS WILL BE | | | REQUIRED. | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
03-22-2021 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
03-22-2021 |
Time |
17:02 |
Rev Time |
5.00 |
| Received By |
eschneid |
Date |
03-16-2021 |
Time |
10:47 |
Sent To |
|
|
| Notes |
| 2021-03-22 17:03:47 | CASE NO. PB1060MM | | | BJS @ BRANDSMART | | | 751 WEST EXECUTIVE CENTER DRIVE | | | | | | - CONTACT ERIC SCHNEIDER @ (561) 822-1446, | | | [email protected] | | | | | | - PLEASE PROVIDE RESPONSES TO REVIEW COMMENTS IN | | | WRITTEN FORMAT. | | | | | | - WHEN RESUBMITTING, PLEASE PROVIDE A MINIMUM OF FOUR | | | (4) PAPER COPIES AND AN ELECTRONIC COPY IN .PNG FORMAT | | | OF ALL PLANS. PLEASE NOTE THAT CHANGES ON THE | | | RESUBMITTED PLANS OR THE SUBMITTAL OF INFORMATION/PLANS | | | TO ADDRESS THE COMMENTS MAY RESULT IN ADDITIONAL | | | COMMENTS. | | | | | | - THE PPRC COMMENTS SHALL BE SUFFICIENTLY ADDRESSED AND | | | SUBMITTED TO THE PLANNING DIVISION TO BE ELIGIBLE TO BE | | | SCHEDULED A PLANNING BOARD MEETING. | | | | | | - PLEASE NOTE THAT IF THE PLANNING DIVISION HAS NOT | | | RECEIVED A RESPONSE TO THE COMMENTS WITHIN 60 DAYS FROM | | | THE DATE OF THESE COMMENTS (BY MAY 22, 2020), THE | | | PLANNING DIVISION MAY NOTIFY THE APPLICANT THAT THE | | | CASE IS CONSIDERED WITHDRAWN. ANY FURTHER ACTION SHALL | | | REQUIRE A NEW DEVELOPMENT APPLICATION. | | | | | | - PLEASE NOTE THAT YOU WILL BE PERMITTED ONE (1) | | | RESUBMITTAL AT NO ADDITIONAL COST. IF PREVIOUSLY-ISSUED | | | COMMENTS CONTINUE TO NOT BE SUFFICIENTLY ADDRESSED, THE | | | APPLICANT WILL BE ASSESSED A RESUBMITTAL FEE. SUCH FEE | | | WILL BE 20% OF THE ORIGINAL APPLICATION FEE ($600). | | | | | | - PUBLIC HEARING NOTIFICATION SIGNAGE SHALL BE POSTED | | | IN ACCORDANCE WITH THE REQUIREMENTS OF SECTION | | | 94-39(I)(5) OF THE ZONING AND LAND DEVELOPMENT | | | REGULATIONS. | | | | | | INNOVATIVE FEATURES LISTED IN JUSTIFICATION STATEMENT | | | | | | 1) PLANNED DEVELOPMENT WAIVERS ARE TO ENCOURAGE THE USE | | | OF INNOVATIVE LAND PLANNING AND DEVELOPMENT TECHNIQUES | | | TO CREATE MORE DESIRABLE AND ATTRACTIVE DEVELOPMENT IN | | | THE CITY. THE ITEMS LISTED BELOW ARE STATED AS THE | | | INNOVATIVE LAND PLANNING AND DEVELOPMENT TECHNIQUES | | | FROM THE JUSTIFICATION STATEMENT AND STAFF'S RESPONSE: | | | | | | A. PROPOSED INTERCONNECTIVITY TO THE ADJACENT SITE **** | | | THE SITE PLAN DOES SHOW INTERCONNECTIVITY; HOWEVER, IT | | | DOES NOT ALIGN WITH THE CARWASH NEXT DOOR. THIS WILL BE | | | DISCUSSED IN MORE DEPTH LATER IN THE COMMENTS. | | | B. SIGNIFICANTLY UPGRADING THE LANDSCAPED OPEN SPACE | | | **** THE LANDSCAPE AREA BEHIND BRANDSMART THAT IS | | | REQUIRED BY ORDINANCE NO. 3122-98 IS PROPOSED TO HAVE | | | ALL OF THE EXISTING MATURE TREES AND PALMS EITHER | | | RELOCATED OR REMOVED. PLEASE NOTE THE LANDSCAPE COMMENT | | | REQUIREMENT THAT YOU MUST PROVIDE THE CALCULATIONS THAT | | | YOU ARE INCREASING THE TREE CANOPY/MASS IN THIS AREA. | | | THE PLAN REPLACES THE BERMED LANDSCAPE AREA WITH THE | | | DETENTION AREA, WHICH PROVIDES LESS VISUAL BUFFERING. | | | NOTE: ONCE STAFF HAS THIS ANALYSIS, IT CAN BE | | | DETERMINED IF THERE IS AN UPGRADE. PLEASE PROVIDE THE | | | SAME ANALYSIS FOR THE AREA IN FRONT OF THE PROPOSED | | | BJS. | | | C. OFFERING A NEW PEDESTRIAN FRIENDLY PARK | | | AREA/WALKABLE AMENITIES **** THIS NEEDS TO BE UPDATED | | | TO REFLECT IS A BOARDWALK THROUGH A BIOSWALE AREA. | | | THERE IS NO LONGER A SEAT WALL, BENCHES, A DECORATIVE | | | CONCRETE PATH AND PAVER PLAZA. ADDITIONALLY, AS | | | PROPOSED, THE BOARDWALKS THROUGH THE BIOSWALE AREA (IN | | | ACTUALITY A STANDARD BAHIA GRASS DRY DETENTION AREA) | | | DOES NOT MEET THE THRESHOLD OF INNOVATIVE LANDS | | | PLANNING TO OFF SET DESIGN THAT IS PROPOSED AND THE | | | WAIVERS REQUIRED BY THE DESIGN. IN ORDER TO COMPLY, THE | | | BIOSWALE NEEDS TO BE TRULY DESIGNED (AND MAINTAINED) AS | | | A BIOSWALE THAT PROVIDES BOTH NATURAL DRAINAGE | | | FILTERING AND HABITAT. THE TWO PROPOSED BOARDWALKS NEED | | | TO CONNECT PARALLEL TO EXECUTIVE CENTER DRIVE SO THAT | | | USERS CAN TRAVERSE THE LENGTH OF THE BIOSWALE. | | | D. INCLUDE OVERALL DESIGN GUIDELINES FOR THE INFILL AND | | | REDEVELOPMENT OF THE PCD **** TO REPEAT, THE CREATION | | | OF DESIGN GUIDELINES THAT JUST INCLUDE THE WAIVERS IS | | | NOT A JUSTIFICATION FOR THE WAIVERS REQUESTED AND ARE | | | NOT JUSTIFICATION FOR A PLANNED DEVELOPMENT. | | | E. REDUCE THE IMPACT OF THE REQUESTED PCD WAIVERS BY | | | NEW PROJECT DESIGN GUIDELINES **** TO REPEAT, DESIGN | | | GUIDELINES THAT RESTATE THE WAIVERS DO NOT REDUCE THEIR | | | IMPACT. | | | F. CREATE A POA FOR THE OVERALL MAINTENANCE CARE AND | | | UPKEEP OF THE NEW COMMON AREAS **** CREATING A POA FOR | | | COMMON AREA MAINTENANCE IS NOT INNOVATIVE AND SHOULD BE | | | A GIVEN FOR ANY COMMERCIAL PROJECT. | | | G. THE SITE'S REDEVELOPMENT WILL BRING ADDITIONAL AD | | | VALOREM TAX BASE TO THE CITY **** ADDITIONAL AD VALOREM | | | TAX BASE IS NOT AN INNOVATIVE LAND PLANNING DEVELOPMENT | | | TECHNIQUE AND DOES NOT RESULT IN DESIRABLE AND | | | ATTRACTIVE DEVELOPMENT. | | | H. THE OVERALL PROJECT WILL BE AN ECONOMIC VALUE-ADDED | | | ADDITION TO THE CITY'S CONTINUED ECONOMIC SUCCESS **** | | | AN ECONOMIC VALUE-ADDED PROJECT NOT AN INNOVATIVE LAND | | | PLANNING DEVELOPMENT TECHNIQUE AND DOES NOT RESULT IN | | | DESIRABLE AND ATTRACTIVE DEVELOPMENT. | | | | | | 2) REPEAT COMMENT: THE PROPOSED SITE DESIGN DOES NOT | | | INCLUDE THE USE OF SUFFICIENT INNOVATIVE LAND PLANNING | | | AND DEVELOPMENT TECHNIQUES TO CREATE A DESIRABLE AND | | | ATTRACTIVE DEVELOPMENT TO JUSTIFY THE GRANTING OF THE | | | REQUESTED WAIVERS. WHILE THE REVISED DESIGN ALONG | | | EXECUTIVE CENTER DRIVE HAS STARTED TO HEAD IN THE RIGHT | | | DIRECTION, THE TWO DETENTION AREAS SURROUNDED BY TREES | | | NEED TO BE ENHANCED AND TURNED INTO TRUE BIOSWALES WITH | | | THE LARGER ONE (IN FRONT OF BRANDSMART) HAVING THE | | | BOARDWALK TRAVERSING ITS LENGTH TO APPROACH THE IN | | | INNOVATIVE LAND PLANNING AND DEVELOPMENT TECHNIQUES TO | | | CREATE MORE DESIRABLE AND ATTRACTIVE DEVELOPMENT IN THE | | | CITY. YOU WILL ALSO SEE THE ENHANCEMENTS TO THE BJS | | | FA?ADE THAT WILL RESULT IN A MORE ATTRACTIVE PEDESTRIAN | | | EXPERIENCE. | | | | | | WAIVERS | | | | | | 3) STAFF HAS REVIEWED THE WAIVERS LISTED IN THE | | | JUSTIFICATION STATEMENT AS WELL AS WHAT STAFF HAS | | | IDENTIFIED BASED ON THE PLANS AND HAS PROVIDED THEM | | | BELOW WITH COMMENTARY. | | | | | | A. WAIVER REQUESTED FOR NUMBER OF ON SITE PARKING | | | SPACES REQUIRED - PLANNING STAFF HAS REVIEWED THE | | | PARKING STUDY AND IS AWAITING INPUT FROM TRAFFIC | | | ENGINEERING FOR FINAL COMMENTS. | | | | | | B. INTERIOR LOT LINE BUFFER REQUIREMENTS - STAFF WOULD | | | ACCEPT THE WAIVER REQUEST; HOWEVER, SINCE THERE ARE | | | LOCATIONS ALONG THE EXTERIOR BUFFERS THAT DO NOT | | | MINIMUM LANDSCAPE BUFFER REQUIREMENTS, STAFF CANNOT | | | JUSTIFY THAT THE INTENT OF THE INTERNAL LANDSCAPE | | | BUFFERS ARE BEING MET BY THE PROVISION OF THE EXTERNAL | | | LANDSCAPE BUFFERS. IF EXTERNAL BUFFER REQUIREMENTS ARE | | | MET, THE MORE DESIRABLE AND ATTRACTIVE DEVELOPMENT | | | BASED ON THE PROVISION OF A TRUE BIOSWALE WITH FULL | | | BOARDWALK CAN OFFSET THIS WAIVER REQUEST. | | | | | | C. MINIMUM BUILDING SETBACKS - NEED HEIGHT OF | | | BRANDSMART TO VERIFY THE REQUIRED SIDE SETBACK (10 | | | FEET) TO SEE IF A WAIVER IS REQUIRED. IF NEEDED, THE | | | MORE DESIRABLE AND ATTRACTIVE DEVELOPMENT BASED ON THE | | | PROVISION OF A TRUE BIOSWALE WITH FULL BOARDWALK CAN | | | OFFSET THIS WAIVER REQUEST. | | | | | | D. THERE IS NO MAXIMUM BUILDING HEIGHT IN A GENERAL | | | COMMERCIAL DISTRICT SO THE LISTED WAIVER TO BUILDING | | | HEIGHT DOES NOT APPLY AND NEEDS TO BE REMOVED. NOTE: | | | TALLER BUILDINGS REQUIRE GREATER SETBACKS, BUT THAT, IF | | | REQUIRED, IS COVERED BY COMMENT #3C. | | | | | | E. NUMBER OF SIGNS ON THE BJS - 3 PERMITTED, 6 | | | PROPOSED. MEETS SF ALLOWANCE. THE MORE DESIRABLE AND | | | ATTRACTIVE DEVELOPMENT BASED ON THE PROVISION OF A TRUE | | | BIOSWALE WITH FULL BOARDWALK CAN OFFSET THIS WAIVER | | | REQUEST. | | | | | | F. NUMBER OF SIGNS ON THE FUEL CANOPY - 3 PERMITTED, 4 | | | PROPOSED. THE MORE DESIRABLE AND ATTRACTIVE DEVELOPMENT | | | BASED ON THE PROVISION OF A TRUE BIOSWALE WITH FULL | | | BOARDWALK CAN OFFSET THIS WAIVER REQUEST. | | | | | | G. SIGNS ON THE SHORT END OF THE FUEL CANOPY EXCEED | | | REQUIRED SIGNAGE SQUARE FOOTAGE ALLOWANCE. STAFF IS NOT | | | PREPARED TO AGREE TO THIS WAIVER. | | | | | | H. LISTED WAIVER FOR BACKING INTO A STREET DOES NOT | | | APPLY AND NEEDS TO BE REMOVED. | | | | | | I. LISTED WAIVER OF 18 SPACES IN A ROW DOES NOT APPLY | | | AND NEEDS TO BE REMOVED. REGARDLESS, STAFF WILL NOT | | | SUPPORT THIS WAIVER SINCE THE SITE IS ALREADY | | | REQUESTING TO HAVE NO LANDSCAPE BUFFER BETWEEN THE TWO | | | PARCELS AND THE PARCEL LINES ARE IN THE PARKING AREAS. | | | THIS WAIVER WOULD REDUCE PARKING LOT LANDSCAPE. | | | | | | J. NOT PLANTING TREES IN THE BUFFER ALONG I-95 IN FRONT | | | OF THE SIGNS. STAFF DOES NOT SUPPORT REDUCTIONS IN THE | | | PLACEMENT OF BUFFER LANDSCAPE, ESPECIALLY FOR SIGNS. | | | | | | K. NOT PLANTING ALONG A PORTION OF THE SITE ADJACENT TO | | | FUTURE CARWASH DUE TO EASEMENT. STAFF HAS COVERED THIS | | | IN THE EASEMENT SECTION OF THE COMMENTS. | | | | | | 4) THE SITE REQUIRES A MINOR SUBDIVISION, BUT NO PLAT | | | WAS PROVIDED FOR REVIEW. | | | | | | 5) THE FAR TABLE ON SHEET C101.0 IS INCORRECT. THE | | | MAXIMUM FAR FOR THE SITE IS 1.0, NOT 2.0. WHILE THE | | | SITE COMPLIES, THE TABLE NEEDS TO BE CORRECTED. | | | | | | PARKING | | | | | | 6) THE PLANS NOW IDENTIFY COMPACT SPACES, WHICH ARE ALL | | | DESIGNATED AS EMPLOYEE PARKING SPACES. WHERE DO | | | EMPLOYEES WITH NON-COMPACT CARS PARK? | | | | | | 7) THE BRANDSMART EMPLOYEE COMPACT SPACES MUST BE | | | LABELED ON THE PLAN. | | | | | | 8) THE EMPLOYEE PARKING SPACES ADJACENT TO THE 0.34 | | | ACRE DRY DETENTION AREA SHOULD HAVE THE CURB AT 14 FEET | | | WITH A TWO FOOT OVERHANG AND REMOVE THE WHEEL STOPS | | | (NOT BOTH A CURB AND WHEEL STOPS). NOTE: THERE MUST BE | | | A MINIMUM OF 16 FEET FROM THE END OF THE PARKING SPACE | | | TO THE EMPLOYEE PARKING SIGN POST OR THE PARKING SPACE | | | IS NONCOMPLIANT. | | | | | | 9) THE SIGN POSTS BETWEEN THE FACING EMPLOYEE PARKING | | | SPACES ARE ONE FOOT IN DIAMETER, WHICH ENCROACH INTO | | | THE PARKING SPACES AND MAKE THE 16 FOOT DEEP COMPACT | | | PARKING SPACES NONCOMPLIANT. | | | | | | 10) THE SIGN POSTS BETWEEN THE FACING TIRE CENTER | | | PARKING SPACES ARE ONE FOOT IN DIAMETER, WHICH ENCROACH | | | INTO THE PARKING SPACES MAKING THE SPACES NO LONGER | | | CODE COMPLIANT AS THEY ARE NO LONGER 18 FEET DEEP. | | | | | | 11) THE SIGN POSTS BETWEEN THE FACING MEMBER WITH | | | INFANT PARKING SPACES ARE ONE FOOT IN DIAMETER, WHICH | | | ENCROACH INTO THE PARKING SPACES MAKING THE SPACES NO | | | LONGER CODE COMPLIANT AS THEY ARE NO LONGER 18 FEET | | | DEEP. | | | | | | 12) THE LIGHT POSTS IN THE PARKING ROWS ON THE EASTERN | | | PARKING AREA MUST BE LOCATED IN THE CORNER WHERE THE | | | FOUR SPACES MEET, NOT IN THE MIDDLE AS SHOWN AS THIS | | | RENDERS THE PARKING SPACES NON-COMPLIANT BASED ON THE | | | PARKING SPACE NO LONGER BEING 18 FEET DEEP. | | | | | | 13) UPDATED COMMENT: WHERE THERE IS NOT PLANNED TO BE A | | | VEHICLE OVERHANG AT THE FRONT OF THE PARKING SPACES, | | | WHEEL STOPS MUST BE PROVIDED AND SHOWN ON THE PLANS. | | | YOU SHOULD NOT BE INSTALLING WHEEL STOPS AND CURBS. YOU | | | THE CURB SHOULD BE PULLED BACK TO THE WHEEL STOP LINE | | | WITH THE OVERHANG PROVIDED. | | | | | | 14) PARKING PROVIDED ? VERIFIED AFTER THE LANDSCAPE | | | CORRECTIONS ARE MADE. | | | | | | 15) REPEAT COMMENT: NO BICYCLE PARKING WAS PROVIDED. | | | CODE COMPLIANT BICYCLE PARKING, BASED ON THE NUMBER OF | | | PARKING SPACES PROVIDED, IS REQUIRED. | | | | | | SITE CIRCULATION | | | | | | 16) THE CROSS ACCESS POINT DOES NOT ALIGN WITH THE | | | LOCATION SHOWN ON THE RECENTLY SUBMITTED CARWASH | | | REDEVELOPMENT ON THE OLD CHINESE RESTAURANT PARCEL. | | | BRIAN CHEGUIS STATED THAT HE HAD COORDINATED WITH THE | | | KIMLEY HORN TEAM TO ALIGN THE CROSS ACCESS. THE CROSS | | | ACCESS POINT IS FURTHER TO THE WEST FROM WHERE IT IS | | | SHOWN ON YOUR PLAN, WHICH CREATES A SAFER SITUATION | | | THAN THE LOCATION THAT YOU SHOW CLOSER TO EXECUTIVE | | | CENTER DRIVE. PLEASE SHOW ALIGN YOUR PLANS WITH THE | | | CARWASH CROSS ACCESS LOCATION. | | | | | | 17) THE CARWASH APPLICANT PROVIDED A COPY OF THE | | | EASEMENT WITH COVENANTS AND RESTRICTIONS COVERING THE | | | CROSS ACCESS AREA. IT INDICATES THAT BEST BUY HAS AN | | | INTEREST IN THE CROSS ACCESS, SPECIFICALLY A DRIVE TO | | | EXECUTIVE CENTER DRIVE. PLEASE PROVIDE VERIFICATION | | | THAT BEST BUY HAS RELEASED THEIR INTEREST IN THE | | | EASEMENT. THE SITE PLAN SHOWS LANDSCAPING OBSTRUCTING | | | BEST BUY FROM UTILIZING THE EASEMENT. PLEASE NOTE THAT | | | REGARDLESS OF WHAT IS STATED IN THE EASEMENT, BEST BUY | | | HAS NO RIGHTS TO THE INSTALLATION OF AN OFF PREMISE | | | SIGN, WHICH WOULD BE IN VIOLATION OF THE ZONING AND | | | LAND DEVELOPMENT REGULATIONS. | | | | | | SIGNAGE | | | | | | 18) REPEAT COMMENT: THE ISLAND WITH THE EXISTING | | | BRANDSMART SIGN IS AN INTERIOR PARKING ISLAND AND IS | | | THUS REQUIRED TO CONTAIN A CODE COMPLIANT TREE. | | | | | | 19) REPEAT COMMENT: PROVIDE WHAT THE BJS FUEL STATION | | | DIRECTIONAL SIGNS WILL LOOK LIKE. PLEASE NOTE THAT IF | | | THE SIGNS ARE PROPOSED TO INCLUDE BJS COPY, THEN THEY | | | ARE CONSIDERED FREE STANDING SIGNS AND ARE REQUIRED TO | | | COMPLY WITH THE FREESTANDING SIGN REQUIREMENTS. **** NO | | | DETAILS OF THESE SIGNS WERE PROVIDED. IF THE REQUEST IS | | | APPROVED WITHOUT SIGN DETAILS, THEN THERE MAY BE NO | | | DEVIATION FROM THE SIGN REGULATIONS WHEN THESE ARE | | | SUBMITTED. THIS INCLUDES NO BJS LOGO BEING PERMITTED. | | | | | | 20) REPEAT COMMENT: PROVIDE A GRAPHIC SHOWING THE SIZE | | | AND HEIGHT OF THE EXISTING MONUMENT SIGNS THAT ARE | | | PROPOSED TO BE RELOCATED ALONG EXECUTIVE CENTER DRIVE. | | | | | | 21) UPDATED COMMENT: PROVIDE THE SIZE OF THE MONUMENT | | | SIGNS ALONG I-95, BOTH THE EXISTING AND THE PROPOSED | | | SIGN. **** THE COMMENT RESPONSE STATES THAT A SIGN | | | PACKAGE WAS SUBMITTED. THE ONLY SIGN PACKAGE SUBMITTED | | | WAS FOR THE WALL SIGNS. | | | | | | 22) THE SIGN REGULATIONS ONLY PERMIT ONE WALL SIGN PER | | | BUSINESS PLUS TWO ADDITIONAL SIGNS. THE BJS ELEVATIONS | | | (BOTH STORE AND FUEL CANOPY) SHOW THAT THIS IS | | | EXCEEDED, WHICH REQUIRES WAIVERS. | | | | | | 23) THE SIZE OF THE SIGNS ON THE SHORT SIDES OF THE | | | FUEL CANOPY EXCEED THE PERMITTED SIGNAGE ALLOWANCE. | | | THESE MUST EITHER BE REMOVED, REDUCE OR A WAIVER | | | APPROVED. | | | | | | ELEVATIONS | | | | | | 24) THE DIMENSIONS ON THE ELEVATION DRAWINGS DO NOT | | | MEET THE LISTED SCALE. PROVIDE THE BUILDING LENGTH | | | DIMENSIONS, SO STAFF IS UNABLE TO VERIFY THE ELEVATIONS | | | MEET THE SITE PLAN BUILDING SIZE. DUE TO THE INCORRECT | | | SCALE, STAFF IS UNABLE TO EVEN SCALE THE DRAWINGS TO | | | DETERMINE THE DIMENSION. | | | | | | 25) THANK YOU FOR PROVIDING THE BJS ELEVATION DRAWING | | | WITH THE LANDSCAPE SUPERIMPOSED ON IT. THIS VERIFIES | | | THAT THE PEDESTRIAN LEVEL OF THE ELEVATION ALONG | | | EXECUTIVE CENTER DRIVE NEEDS TO BE IMPROVED. THIS CAN | | | BE DONE WITH STUCCO BANDING/DESIGNS OR OTHER WALL | | | APPLICATIONS WITHIN THE RED ROCK PAINTED CONCRETE WALL | | | PANELS TO CREATE PEDESTRIAN LEVEL VISUAL INTEREST. | | | | | | 26) THE BJS ELEVATION PLAN INCLUDES A NOTE STATING, | | | "TOWER ELEVATION SUBJECT TO ADJUSTMENT TO ENABLE N/S | | | VISIBILITY FROM HIGHWAY I-95". THE ELEVATION DRAWINGS | | | NEED TO SHOW THE ACCURATE CONDITIONS THAT ARE BEING | | | APPROVED BY THE CITY. | | | | | | 27) THE ELEVATION DRAWINGS DO NOT SHOW THE GENERATOR | | | ENCLOSURE WALLS. | | | | | | 28) THE MECHANICAL EQUIPMENT ON THE ROOF OF THE FUEL | | | STATION KIOSK NEEDS TO BE FULLY SCREENED. THE PROPOSED | | | SCREENING IS INSUFFICIENT. | | | | | | 29) IN ORDER TO VERIFY THE PROPOSED SETBACKS AND IF | | | SETBACK WAIVERS ARE REQUIRED, PROVIDE THE HEIGHT OF THE | | | BRANDSMART (ELEVATION DRAWING REQUIRED) AND BJS | | | BUILDINGS ON THE RESUBMITTED PLANS. THE HEIGHT | | | MEASUREMENT SHALL CONFORM TO THE ZONING AND LAND | | | DEVELOPMENT CODE METHODOLOGY AS FOLLOWS, "THE HEIGHT | | | SHALL BE MEASURED AS THE VERTICAL DISTANCE FROM THE | | | AVERAGE ELEVATION OF THE FINISHED GRADE OF THE BUILDING | | | TO THE HIGHEST POINT OF THE TOP OF THE STRUCTURE OF A | | | FLAT ROOF, OR TO THE DECK LINE OF A MANSARD ROOF, OR TO | | | THE MEAN HEIGHT LEVEL BETWEEN EAVES AND RIDGE FOR | | | GABLE, HIP, AND GAMBREL ROOFS." NOTE: WHILE THE HEIGHT | | | IS NOT SHOWN CORRECTLY ON THE BJS ELEVATION DRAWING, | | | THE OVERALL HEIGHT OF THE BUILDING SHOWN AT 65 FEET | | | MEETS THE GENERAL COMMERCIAL SETBACK REQUIRED OF 21 | | | FEET FROM THE SIDE PROPERTY LINE. | | | | | | LANDSCAPE | | | | | | 30) REPEAT COMMENT: THERE ARE INSTANCES WHERE TREES ARE | | | FAILED TO BE PROVIDED WITHIN LANDSCAPE ISLANDS AS | | | REQUIRED BY THE ZONING AND LAND DEVELOPMENT | | | REGULATIONS. | | | | | | 31) YOU MAY NOT HAVE 140+ GAPS OF NO BUFFER TREES ALONG | | | I-95. | | | | | | 32) THE TWO DETENTION AREAS ALONG EXECUTIVE CENTER | | | DRIVE ARE TO BE CONSTRUCTED AS A BIOSWALE AND NOT JUST | | | A STANDARD DEPRESSION WITH BAHIA GRASS IN ORDER TO | | | PROVIDE THE ENHANCED THE PEDESTRIAN EXPERIENCE ALONG | | | EXECUTIVE CENTER DRIVE THAT HAS BEEN PART OF THE | | | ORIGINAL BRANDSMART CPD APPROVAL. | | | | | | 33) THE LANDSCAPE MATERIAL ALONG THE EAST SIDE OF THE | | | BRANDSMART BUILDING MUST PROVIDE A SOLID SCREEN TO SIX | | | (6) FEET IN HEIGHT IN LIEU OF PROVIDING ARCHITECTURAL | | | ENHANCEMENTS TO THE FACADE. | | | | | | 34) YOUR RECENT SURVEY SHOWS THAT THE STORMWATER LINE | | | FROM BEST BUY IS NOT WITHIN THE PORTION OF THE DRAINAGE | | | EASEMENT SHOWN ON THE BRANDSMART SITE. YOU NEED TO | | | CONFIRM WHAT IS LOCATED WITHIN THE DRAINAGE EASEMENTS | | | ON THE BRANDSMART SITE (IF DIFFERENT FROM THE SURVEY)? | | | THE NON-EXCLUSIVE OUTFALL DRAINAGE EASEMENT RECORDED IN | | | ORB 11870 PG 300 INCLUDES PROVISIONS FOR TERMINATION OF | | | THE EASEMENTS OF PORTIONS OF EASEMENTS THAT ARE NO | | | LONGER NEEDED. IF NOTHING IS LOCATED WITHIN THE | | | EASEMENT, THIS SHOULD BE PURSUED IN ORDER FOR YOU TO | | | INSTALL THE CODE COMPLIANT BUFFER LANDSCAPE. | | | | | | LIGHTING | | | | | | 35) THANK YOU FOR EXTENDING THE PHOTOMETIC CALCULATIONS | | | TO THE PROPERTY LINE. THE PLAN SHOWS THAT THERE ARE | | | STILL AREAS WHERE THEY EXCEED ONE FOOTCANDLE PAST THE | | | PROPERTY LINE, WHICH IS NOT PERMITTED AND MUST BE | | | CORRECTED. | | | | | | JUSTIFICATION STATEMENT PROPOSED INDIVIDUAL PARCEL | | | DEVELOPMENT STANDARDS | | | | | | 36) THE JUSTIFICATION STATEMENT PROPOSES THE | | | DEVELOPMENT STANDARDS SIMILAR TO WHAT WAS DISCUSSED ON | | | THE PREVIOUS APPLICATION WHICH HAD FIVE PARCELS AND AN | | | INTERNAL ROADWAY. NOW THAT THE PROPOSAL IS TWO PARCELS | | | WHICH COMPLY WITH MOST OF THE GENERAL COMMERCIAL | | | DEVELOPMENT STANDARDS, A LIST OF DEVELOPMENT STANDARDS | | | IS NOT NECESSARY. THE FEW WAIVERS WILL BE COVERED BY A | | | WAIVER TABLE. | | | | | | CONDITION - PRIOR TO ANY CONSTRUCTION, THE FPL MUST | | | PROVIDE A RELEASE OF THE EASEMENTS WHICH CONFLICT WITH | | | THE PROPOSED BJS BUILDING. | | | | | | CONDITION - ALL TRANSFORMERS MUST BE SCREENED. | | | | | | CONDITION - ALL ROOFTOP MECHANICAL EQUIPMENT MUST BE | | | SCREENED TO THE FULL HEIGHT OF THE EQUIPMENT. | | | | | | CONDITION - CROSS UTILITY AGREEMENTS/EASEMENTS WILL BE | | | REQUIRED. | | | | | | | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
12-10-2020 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
12-10-2020 |
Time |
12:47 |
Rev Time |
5.00 |
| Received By |
eschneid |
Date |
12-10-2020 |
Time |
12:43 |
Sent To |
|
|
| Notes |
| 2020-12-10 12:47:58 | CASE NO. PB1060MM | | | BJ'S @ BRANDSMART | | | 751 WEST EXECUTIVE CENTER DRIVE | | | | | | - CONTACT ERIC SCHNEIDER @ (561) 822-1446, | | | [email protected] | | | | | | - PLEASE PROVIDE RESPONSES TO REVIEW COMMENTS IN | | | WRITTEN FORMAT. | | | | | | - WHEN RESUBMITTING, PLEASE PROVIDE A MINIMUM OF FOUR | | | (4) PAPER COPIES AND AN ELECTRONIC COPY IN .PNG FORMAT | | | OF ALL PLANS. PLEASE NOTE THAT CHANGES ON THE | | | RESUBMITTED PLANS OR THE SUBMITTAL OF INFORMATION/PLANS | | | TO ADDRESS THE COMMENTS MAY RESULT IN ADDITIONAL | | | COMMENTS. | | | | | | - THE PPRC COMMENTS SHALL BE SUFFICIENTLY ADDRESSED AND | | | SUBMITTED TO THE PLANNING DIVISION BY 5 PM ON THURSDAY, | | | DECEMBER 23, 2020, TO BE ELIGIBLE TO BE SCHEDULED FOR | | | THE FEBRUARY 16, 2021 PLANNING BOARD MEETING. | | | | | | - PLEASE NOTE THAT IF THE PLANNING DIVISION HAS NOT | | | RECEIVED A RESPONSE TO THE PPRC COMMENTS WITHIN 60 DAYS | | | FROM THE DATE OF THESE COMMENTS/THE PPRC MEETING (BY | | | FEBRUARY 10, 2020), THE PLANNING DIVISION MAY NOTIFY | | | THE APPLICANT THAT THE CASE IS CONSIDERED WITHDRAWN. | | | ANY FURTHER ACTION SHALL REQUIRE A NEW DEVELOPMENT | | | APPLICATION. | | | | | | - PLEASE NOTE THAT YOU WILL BE PERMITTED ONE (1) | | | RESUBMITTAL AT NO ADDITIONAL COST. IF PREVIOUSLY-ISSUED | | | COMMENTS CONTINUE TO NOT BE SUFFICIENTLY ADDRESSED, THE | | | APPLICANT WILL BE ASSESSED A RESUBMITTAL FEE. SUCH FEE | | | WILL BE 20% OF THE ORIGINAL APPLICATION FEE ($600). | | | | | | - PUBLIC HEARING NOTIFICATION SIGNAGE SHALL BE POSTED | | | IN ACCORDANCE WITH THE REQUIREMENTS OF SECTION | | | 94-39(I)(5) OF THE ZONING AND LAND DEVELOPMENT | | | REGULATIONS. | | | | | | GENERAL | | | | | | 1) INSUFFICIENT JUSTIFICATION WAS PROVIDED AS TO WHY | | | STAFF SHOULD SUPPORT THE WAIVERS THAT ARE REQUESTED. | | | PLANNED DEVELOPMENT WAIVERS ARE TO ENCOURAGE THE USE OF | | | INNOVATIVE LAND PLANNING AND DEVELOPMENT TECHNIQUES TO | | | CREATE MORE DESIRABLE AND ATTRACTIVE DEVELOPMENT IN THE | | | CITY. THE ITEMS LISTED BELOW ARE STATED AS THE | | | INNOVATIVE LAND PLANNING AND DEVELOPMENT TECHNIQUES | | | FROM THE JUSTIFICATION STATEMENT AND STAFF'S RESPONSE: | | | | | | A. PROPOSED INTERCONNECTIVITY TO THE ADJACENT SITE **** | | | THERE IS NO INTERCONNECTIVITY DESIGNED INTO THE SITE | | | PLAN AT THE PROPERTY BOUNDARY. ADDITIONALLY, THE DESIGN | | | OF THE TRAFFIC PATTERN WOULD NOT PERMIT VEHICLES FROM | | | THE BRANDSMART SITE TO SAFELY ACCESS THE ADJACENT SITE. | | | THIS WILL BE DISCUSSED IN DEPTH LATER IN THE COMMENTS. | | | B. SIGNIFICANTLY UPGRADING THE LANDSCAPED OPEN SPACE | | | **** THE LANDSCAPE ARE REQUIRED BY ORDINANCE NO. | | | 3122-98 IS PROPOSED TO HAVE ALL OF THE EXISTING MATURE | | | TREES REMOVED AND REPLACED BY CODE REQUIRED MINIMUM | | | SIZE TREES AS WELL AS BEING REDUCED IN AREA BY OVER | | | 60%. THIS IS NOT A SIGNIFICANT UPGRADE, BUT RATHER A | | | DOWNGRADE IN THE LANDSCAPE OPEN SPACE. | | | OFFERING A NEW PEDESTRIAN FRIENDLY PARK AREA **** THE | | | PROPOSED PARK, WITH THE SEAT WALL, SHADE TREES, | | | BENCHES, LIGHTED BOLLARDS DECORATIVE CONCRETE PATH AND | | | PAVER PLAZA DO NOT OFF SET THE NON-INNOVATIVE LAND | | | PLANNING DESIGN THAT IS PROPOSED AND THE WAIVERS | | | REQUIRED BY THE DESIGN. | | | C. INCLUDE OVERALL DESIGN GUIDELINES FOR THE INFILL AND | | | REDEVELOPMENT OF THE PCD **** THE CREATION OF DESIGN | | | GUIDELINES THAT INCLUDE THE WAIVERS IS NOT A | | | JUSTIFICATION FOR THE WAIVERS REQUESTED. | | | D. REDUCE THE IMPACT OF THE REQUESTED PCD WAIVERS BY | | | NEW PROJECT DESIGN GUIDELINES **** THE PROPOSED DESIGN | | | GUIDELINES RESTATE THE WAIVERS AND DO NOT REDUCE THEIR | | | IMPACT. | | | E. CREATE A POA FOR THE OVERALL MAINTENANCE CARE AND | | | UPKEEP OF THE NEW COMMON AREAS **** CREATING A POA FOR | | | COMMON AREA MAINTENANCE IS NOT INNOVATIVE AND SHOULD BE | | | A GIVEN FOR ANY COMMERCIAL PROJECT. | | | F. THE SITE'S REDEVELOPMENT WILL BRING ADDITIONAL AD | | | VALOREM TAX BASE TO THE CITY **** ADDITIONAL AD VALOREM | | | TAX BASE IS NOT AN INNOVATIVE LAND PLANNING DEVELOPMENT | | | TECHNIQUE AND DOES NOT RESULT IN DESIRABLE AND | | | ATTRACTIVE DEVELOPMENT. | | | G. THE OVERALL PROJECT WILL BE AN ECONOMIC VALUE-ADDED | | | ADDITION TO THE CITY'S CONTINUED ECONOMIC SUCCESS **** | | | AN ECONOMIC VALUE-ADDED PROJECT NOT AN INNOVATIVE LAND | | | PLANNING DEVELOPMENT TECHNIQUE AND DOES NOT RESULT IN | | | DESIRABLE AND ATTRACTIVE DEVELOPMENT. | | | | | | 2) THE PROPOSED SITE DESIGN DOES NOT INCLUDE THE USE OF | | | SUFFICIENT INNOVATIVE LAND PLANNING AND DEVELOPMENT | | | TECHNIQUES TO CREATE A DESIRABLE AND ATTRACTIVE | | | DEVELOPMENT TO JUSTIFY THE GRANTING OF THE REQUESTED | | | WAIVERS. | | | | | | 3) STAFF DOES NOT SUPPORT THE PROPOSED DESIGN AS | | | PROPOSED. THE CITY'S DESIGN VISION ALONG EXECUTIVE | | | CENTER DRIVE IS FOR BUILDINGS TO ADDRESS THE STREET AND | | | HAVE FRONT DOORS FACING THE STREET. WHILE THE | | | BRANDSMART BUILDING DOES NOT MEET THIS STANDARD, | | | ORDINANCE NO. 3122-98 CONTEMPLATED THE CONSTRUCTION OF | | | A RETAIL AREA TO ACHIEVE THIS GOAL. THE OPEN LANDSCAPED | | | OPEN SPACE EXISTS WITH HE GOAL OF IT EVENTUALLY HAVING | | | AN INFILL BUILDING. IF THIS DOES NOT OCCUR, THE AREA IS | | | REQUIRED TO INCLUDE ADDITIONAL LANDSCAPE, WHICH WAS | | | INSTALLED. THE REMOVAL OF THE MATURE LANDSCAPE AND THE | | | REDUCTION IN AREA OF THE REQUIRED LANDSCAPE AREA TO THE | | | EAST OF THE BRANDSMART BUILDING AND ITS REPLACEMENT | | | WITH PARKING IS IN OPPOSITION WITH THE ORIGINAL | | | APPROVED DESIGN. | | | | | | 4) THE CONSTRUCTION OF THE REAR OF THE PROPOSED BJ'S | | | BUILDING, INCLUDING PARKING AND THE GENERATORS ALONG | | | EXECUTIVE CENTER DRIVE ALSO DO NOT SUPPORT THE CITY'S | | | DESIGN VISION ALONG EXECUTIVE CENTER DRIVE FOR | | | NEIGHBORHOOD ORIENTED COMMERCIAL USES WHICH ADDRESS THE | | | STREET AND HAVE FRONT DOORS FACING THE STREET. MOVING | | | THE BJ'S IN THE SOUTHWEST CORNER OF THE SITE WOULD NOT | | | CREATE A NEGATIVE STREET FRONTAGE ALONG EXECUTIVE | | | DRIVE. THIS WOULD THEN PERMIT A FUTURE BUILDING | | | ORIENTED TOWARD EXECUTIVE DRIVE TO BE INSTALLED IN THE | | | NORTHEAST CORNER OF THE SITE. | | | | | | 5) SITE A1 AND SITE A2 ARE TWO DISTINCT PARCELS AND THE | | | OPEN SPACE, FLOOR AREA RATIO, LANDSCAPE AREA, | | | IMPERVIOUS SURFACE, ETC. MUST BE CALCULATED SEPARATELY | | | FOR EACH ONE. | | | | | | 6) PROVIDE THE DIMENSIONS, INCLUDING THE HEIGHT OF THE | | | PROPOSED TRANSFORMERS. THE TRANSFORMERS MUST BE | | | SCREENED WITH A LANDSCAPE HEDGE FROM EXECUTIVE CENTER | | | DRIVE. | | | | | | 7) PROVIDE THE DIMENSIONS, INCLUDING THE HEIGHT OF THE | | | PROPOSED GENERATORS. NOTE: THE GENERATORS MAY NOT BE | | | LOCATED ADJACENT TO THE PROPOSED LINEAR PARK OR | | | ADJACENT TO EXECUTIVE CENTER DRIVE. ALL PLANS MUST SHOW | | | THE SAME CONDITIONS ONCE THE GENERATORS ARE PROPERLY | | | LOCATED. | | | | | | 8) THE PROPANE TANK IS REQUIRED TO BE SCREENED IN | | | ACCORDANCE WITH SECTION 94-315A. | | | | | | 9) PLEASE EXPLAIN WHY THE SQUARE FOOTAGE LISTED ON THE | | | BUILDING FOOTPRINT DRAWINGS IS LARGER THAN THE SQUARE | | | FOOTAGE LISTED AS COVERED BY BUILDINGS IN THE VARIOUS | | | AREA BREAKDOWN TABLES. | | | | | | 10) IT IS STAFF?S UNDERSTANDING THAT THE SITE WAS | | | CAPPED DUE TO ARSENIC ISSUES WHEN THE BRANDSMART WAS | | | ORIGINALLY CONSTRUCTED. PLEASE EXPLAIN HOW THE | | | EXCAVATION FOR THE NEW UNDERGROUND INFRASTRUCTURE AND | | | THE FUTURE ABOVEGROUND FEATURES (NEW LANDSCAPE AREAS, | | | BUILDING FOUNDATIONS, ETC.) AND REMOVAL OF THE | | | RETENTION AREAS WILL COMPLY WITH THE DEP REGULATIONS. | | | | | | 11) SINCE THE PREVIOUS MAJOR SUBDIVISION REQUEST WAS | | | HEARD BY THE PLANNING BOARD, THE NEW SUBDIVISION | | | REQUEST REQUIRES A NEW APPLICATION, INCLUDING FEES AND | | | REVIEWS. | | | | | | 12) THE FPL LETTER STATES THAT THE PROPOSED BUILDING | | | INTERFERES WITH EXISTING UNDERGROUND FACILITIES AND | | | ENCROACHES ON THEIR EASEMENTS. HOW IS THIS BEING | | | ADDRESSED? | | | | | | PARKING | | | | | | 13) THE BUILDING DIVISION MUST APPROVE THE PROVISION OF | | | A NON-ADA PARKING SPACE CLOSER THAN AN ADA PARKING | | | SPACE CLOSEST TO THE TIRE STORE ENTRANCE. | | | | | | 14) PARKING ROWS EXCEEDING 10 SPACES NOT PERMITTED. THE | | | ENTIRE PARKING LOT IS BEING REBUILT, SO THERE IS NO | | | JUSTIFICATION TO PERMIT MORE THAN THE CODE ALLOWED 10 | | | SPACES IN A ROW. | | | | | | 15) THE CITY MEASURES THE WIDTH OF PARKING SPACES FROM | | | THE CENTER OF THE DOUBLE STRIPE. THE DIMENSION TAGS FOR | | | SOME OF THE PARKING SPACES ON THE SITE PLAN ARE | | | MEASURED FROM THE OUTSIDE OF ONE STRIPE TO THE CENTER | | | OF THE DOUBLE STRIPING ON THE OTHER SIDE, WHICH | | | INCORRECTLY SHOWS THE STALL WIDTHS. SHOW DIMENSION | | | LINES IN ACCORDANCE WITH THE CITY REQUIREMENTS SO STAFF | | | CAN VERIFY COMPLIANCE. NOTE: THIS IS CORRECTLY SHOWN ON | | | THE STRIPING PLAN. | | | | | | 16) THE DIMENSION WIDTH OF SOME OF THE PARKING SPACES | | | ON THE NORTH AND EAST SIDES OF THE PROPOSED BJ'S AND | | | THE EAST SIDE OF THE BRANDSMART ARE LISTED AS EIGHT (8) | | | FEET. ARE THESE PROPOSED TO BE COMPACT PARKING SPACES? | | | IF SO THEN THEY NEED TO BE DESIGNATED ON THE PLAN AND | | | PROVIDED ON THE PARKING TABLE. | | | | | | 17) WHERE THERE IS NOT PLANNED TO BE A VEHICLE OVERHANG | | | AT THE FRONT OF THE PARKING SPACES, WHEEL STOPS MUST BE | | | PROVIDED AND SHOWN ON THE PLANS. | | | | | | 18) THERE ARE FOUR PARKING SPACES SOUTH OF THE | | | BRANDSMART THAT ARE SHOW AS 15.9 FEET DEEP WITH AN | | | OVERHANG. SPACES MUST BE 16 FEET DEEP IN THIS | | | SITUATION. NOTE: THIS IS NOT THE SAME DIMENSION SHOWN | | | ON THE STRIPING PLAN. ALL PLANS MUST SHOW THE SAME | | | CONDITIONS. | | | | | | 19) THERE ARE THREE PARKING SPACES IN EAST OF THE | | | BRANDSMART (IN THE ROW WITH 13 SPACES) THAT ARE NOT 18 | | | FEET DEEP. | | | | | | 20) THE EAST-WEST PARKING ROW CLOSEST TO THE FUEL PUMPS | | | IS INCORRECTLY TAGGED WITH 12 PARKING SPACES WHEN ONLY | | | 10 ARE PROVIDED. | | | | | | 21) PROVIDE VERIFICATION OF THE PARKING SPACE WIDTH ON | | | THE PARKING ROW DUE SOUTH OF THE BRANDSMART ENTRANCE | | | WHERE ONE OF THE SPACES IS NARROWER THAN THE ONE ACROSS | | | FROM IT (NEXT TO THE LANDSCAPE ISLAND). | | | | | | 22) COMPACT PARKING MAY OCCUPY NO MORE THAN 30% OF THE | | | REQUIRED PARKING SPACES, BE MARKED, AND NEED TO BE | | | DISTRIBUTED EQUALLY THROUGHOUT THE PARKING LOT. THEY | | | MAY NOT ALL BE CONCENTRATED AS SHOWN. | | | | | | 23) THE PARKING SPACES MARKED AS "PROPANE PARKING ONLY" | | | MAY NOT BE COUNTED TOWARD MEETING THE MINIMUM PARKING | | | REQUIREMENTS. | | | | | | 24) PARKING PROVIDED | | | | | | A. STAFF ONLY COUNTS 812 PARKING SPACES ON SITE (AFTER | | | REMOVAL OF THE 4 PROPONE ONLY SPACES). | | | | | | B. IN ACCORDANCE WITH SECTION 94-485B.2 ONLY ON-STREET | | | PARKING SPACES DIRECTLY AND WHOLLY ABUTTING THE | | | PROPERTY MAY BE COUNTED TOWARDS THE PARKING | | | REQUIREMENT. ONLY 12 ON STREET PARKING SPACES MEET THIS | | | REQUIREMENT, NOT 42. | | | | | | C. THERE ARE ONLY 824 PARKING SPACES PROVIDED FOR THE | | | PROJECT. NOTE: SITE REDESIGN TO COMPLY WITH OTHER | | | COMMENTS MAY REDUCE THE NUMBER OF PARKING SPACES | | | PROVIDED. | | | | | | 25) PLEASE EXPLAIN WHY THE SQUARE FOOTAGE LISTED ON THE | | | BUILDING FOOTPRINT DRAWINGS IS LARGER THAN THE SQUARE | | | FOOTAGE LISTED FOR EACH BUILDING IN THE PARKING | | | TABULATION TABLE. BASED ON THE BUILDING SQUARE FOOTAGE | | | SHOWN ON THE BUILDING FOOTPRINTS, STAFF CALCULATES THAT | | | 883 PARKING SPACES ARE REQUIRED. BASED ON THIS | | | CALCULATION, THERE IS A DEFICIENCY OF 59 PARKING SPACES | | | ON THE SITE PLAN AS CURRENTLY SHOWN. | | | | | | 26) CROSS UTILITY AGREEMENTS/EASEMENTS WILL BE | | | REQUIRED. | | | | | | SITE CIRCULATION | | | | | | 27) THE CROSS ACCESS POINT NEEDS TO BE SHOWN ON THE | | | PLANS AND CONSTRUCTED TO THE PROPERTY LINE SO THAT WHEN | | | THE ADJOINING SITE IS REDEVELOPED, THEIR SIDE OF THE | | | DRIVE CAN BE DIRECTLY TIED IN TO THE CONNECTION. THE | | | LANDSCAPE NEEDS TO BE ADJUSTED ACCORDINGLY. | | | | | | 28) THE DESIGN OF THE SITE DOES NOT SAFELY PERMIT | | | CUSTOMERS FROM THE BRANDSMART/BJ'S SITE TO ACCESS THE | | | FUTURE CONNECTION. THE NORTHERN DRIVEWAY IS ONE WAY IN | | | A WESTERN DIRECTION, SO IT IS NOT ACCESSIBLE FROM THE | | | PARKING LOT IN FRONT OF THE TIRE SHOP. THE PARKING | | | FIELD ON THE EAST SIDE OF THE BJ'S BUILDING DOES NOT | | | PERMIT SAFE ENTRANCE FROM THE SOUTH SIDE FOR CUSTOMERS | | | USING THE EGRESS DRIVE TO EXECUTIVE CENTER DRIVE. THESE | | | DRIVERS WOULD BE FORCED TO CROSS THE INCOMING TRAFFIC | | | FLOW WITHOUT HAVING A CLEAR LINE OF SIGHT TO VERIFY | | | THAT THE TURNING MOVEMENT IS SAFE. THE DESIGN ALSO | | | ENCOURAGES CUSTOMERS TO LEAVE THE SITE AND TRANSITION | | | BACK TO THE ADJACENT PARCELS VIA LEFT TURN MOVEMENTS | | | ACROSS EXECUTIVE CENTER DRIVE. THIS MOVEMENT ALSO | | | EXACERBATES THE QUEUING DEFICIENCY THAT PALM BEACH | | | COUNTY MENTIONED IN THEIR TPS LETTER. THE SITE NEEDS TO | | | BE REDESIGNED TO PROVIDE SAFE ACCESS TO THE CROSS | | | ACCESS POINT. | | | | | | 29) WHERE IS BRANDSMART DUMPSTER? SHOW THE SANITATION | | | TRUCK VEHICLE MOVEMENTS TO SHOW HOW IT IS PICKED UP. | | | | | | 30) PROVIDE THE TRUCK TURNING MOVEMENTS FOR THE FUEL | | | TRUCKS TO THE GAS STATION AND THE LOADING AREAS FOR | | | BJ?S AND BRANDSMART. | | | | | | 31) PROVIDE INFORMATION AND A DETAIL OF HOW THE FUEL | | | STATION STACKING IS EXPECTED TO FUNCTION. THE CURRENT | | | PLAN APPEARS TO BE CONFIGURED IN SUCH A WAY THAT CARS | | | WILL BE STACKING INTO THE DRIVE AISLE, WHICH IS NOT | | | PERMITTED. | | | | | | SIGNAGE | | | | | | 32) THE EXISTING BRANDSMART SIGN IS SHOWN ON BOTH THE | | | SITE AND LANDSCAPE PLANS IN ITS CURRENT LOCATION. | | | HOWEVER, THE LANDSCAPE PLAN SHOWS A TREE PLANTED ON TOP | | | OF THE SIGN OUTLINE. PLEASE EXPLAIN. THIS PARKING | | | ISLAND REQUIRES A CODE COMPLIANT TREE REGARDLESS OF | | | WHETHER THE SIGN REMAINS OR IS REMOVED. | | | | | | 33) PROVIDE WHAT THE BJ?S FUEL STATION DIRECTIONAL | | | SIGNS WILL LOOK LIKE. PLEASE NOTE THAT IF THE SIGNS ARE | | | PROPOSED TO INCLUDE BJ?S COPY, THEN THEY ARE CONSIDERED | | | FREE STANDING SIGNS AND ARE REQUIRED TO COMPLY WITH THE | | | FREESTANDING SIGN REQUIREMENTS. | | | | | | 34) PROVIDE A GRAPHIC SHOWING THE SIZE AND HEIGHT OF | | | THE EXISTING MONUMENT SIGNS THAT ARE PROPOSED TO BE | | | RELOCATED ALONG EXECUTIVE CENTER DRIVE. | | | | | | 35) PROVIDE THE SETBACKS FOR THE RELOCATED MONUMENT | | | SIGNS FROM EXECUTIVE CENTER DRIVE. | | | | | | 36) PROVIDE THE SETBACKS AND SIZE OF THE MONUMENT SIGNS | | | ALONG I-95, BOTH THE EXISTING AND THE PROPOSED SIGN. | | | | | | 37) THE SIGN REGULATIONS ONLY PERMIT ONE WALL SIGN PER | | | BUSINESS PLUS TWO ADDITIONAL SIGNS. THE BJ'S ELEVATIONS | | | SHOW THAT THIS IS EXCEEDED. | | | | | | 38) PROVIDE THE SIZE OF THE PROPOSED WALL SIGNS SO THAT | | | STAFF CAN VERIFY CODE COMPLIANCE. | | | | | | 39) PARKING AREA INSTRUCTIONAL AND RELATED SIGNS ARE | | | ONLY PERMITTED TO HAVE A MAXIMUM HEIGHT OF SIX (6) | | | FEET. THE PLANS SHOW THE PROPANE AND TIRE STORE SIGNS | | | AT GREATER THAN SIX (6) FEET IN HEIGHT. THIS STANDARD | | | ALSO APPLIES TO THE MEMBER WITH INFANT SIGNS. | | | | | | ELEVATIONS | | | | | | 40) WHILE STAFF IS NOT SUPPORTIVE OF THE CURRENT SITE | | | LAYOUT, IF YOU PLAN TO MOVE FORWARD WITH THIS GENERAL | | | SITE PLAN, THE ELEVATION ALONG EXECUTIVE CENTER DRIVE | | | NEEDS TO BE IMPROVED. | | | | | | 41) WHAT IS OCCURRING IN THE BJ'S TOWER? IS THIS USABLE | | | SQUARE FOOTAGE? | | | | | | 42) PROVIDE DETAILS OF THE PARAPET WALLS FOR BJ'S. | | | THESE MUST BE OF SUFFICIENT HEIGHT TO SCREEN THE | | | ROOFTOP MECHANICAL EQUIPMENT FROM THE NEIGHBORING | | | PROPERTIES, TO INCLUDE THE MALIBU BAY RESIDENTIAL | | | PROPERTY ACROSS EXECUTIVE CENTER DRIVE. | | | | | | 43) PROVIDE THE ELEVATIONS FOR THE FUEL STATION | | | ELEVATIONS. PLEASE NOTE THAT THE LIGHTING UNDER THE | | | CANOPY NEEDS TO BE RECESSED SO THAT NO GLARE IS CAST | | | OFF-SITE. | | | | | | 44) PROVIDE THE SETBACK DIMENSION FOR THE NORTH SIDE OF | | | THE FUEL STATION CANOPY STRUCTURE. | | | | | | LANDSCAPE | | | | | | 45) THERE ARE INSTANCES WHERE TREES ARE FAILED TO BE | | | PROVIDED WITHIN LANDSCAPE ISLANDS AS REQUIRED BY THE | | | ZONING AND LAND DEVELOPMENT REGULATIONS. | | | | | | 46) THERE ARE INSTANCES WHERE THE LIGHTS APPEAR TO | | | CONFLICT WITH THE REQUIRED LANDSCAPE ISLAND TREES, | | | WHICH IS NOT PERMITTED. | | | | | | 47) THE AREA BREAKDOWN TABLE FAILED TO PROVIDE | | | INFORMATION ON THE AMOUNT OF LANDSCAPE ON THE OVERALL | | | SITE OR FOR INDIVIDUAL PARCELS. PLEASE NOTE THAT WHILE | | | THE DRY DETENTION AREAS DO NOT COUNT AS OPEN SPACE, | | | THEY ARE NOT PERMITTED TO COUNT TOWARD MEETING THE 15% | | | LANDSCAPE REQUIREMENT. ADDITIONALLY, SINCE THE | | | DETENTION AREA IS LINED, IT IS NOT PERVIOUS AND MUST BE | | | EXCLUDED FROM THE PERVIOUS CALCULATION. | | | | | | LIGHTING | | | | | | 48) THE PHOTOMETIC CALCULATIONS NEED TO BE CONTINUED TO | | | THE PROPERTY LINE AND MAY NOT EXCEED ONE FOOTCANDLE | | | PAST THE PROPERTY LINE. | | | | | | JUSTIFICATION STATEMENT PROPOSED INDIVIDUAL PARCEL | | | DEVELOPMENT STANDARDS | | | | | | 49) THE JUSTIFICATION STATEMENT PROPOSES THE | | | DEVELOPMENT STANDARDS THAT FOLLOW. STAFF HAS INCLUDED A | | | RESPONSE TO THE PROPOSALS. | | | | | | LANDSCAPED AREA: EACH INDIVIDUAL PARCEL SHALL PROVIDE A | | | MINIMUM OF 10% LANDSCAPED AREA. THE OVERALL MINIMUM PCD | | | LANDSCAPED AREA SHALL BE 15%. ***** WHILE THIS MIRRORS | | | THE PREVIOUS DEVELOPMENT STANDARD THAT STAFF SUPPORTED, | | | THE PREVIOUS SUPPORT WAS BASED ON THE MITIGATION | | | PROVIDED FOR THE REQUESTED WAIVER TO THE INDIVIDUAL | | | PARCEL LANDSCAPE MINIMUM. THE DESIGN OF THE SITE DOES | | | NOT JUSTIFY STAFF SUPPORT OF THIS WAIVER REQUEST. | | | PERIMETER PARCEL BUFFER: EACH INDIVIDUAL PARCEL SHALL | | | PROVIDE A MINIMUM OF A FIVE (5) LANDSCAPED BUFFER | | | AROUND THE PERIMETER OF EACH PARCEL EXCEPT WHEN | | | ADJACENT TO AN EXISTING WATER BODY OR THE I-95 | | | RIGHT-OF-WAY. ***** STAFF WILL NOT SUPPORT A BUFFER | | | REDUCTION AT ANY POINT ALONG THE PERIMETER OF THE SITE. | | | ENCROACHMENTS: LANDSCAPED BUFFERS MAY ENCROACH INTO | | | EXISTING UTILITY EASEMENTS. ***** THE LANDSCAPE BUFFER | | | MUST BE INSTALLED OUTSIDE OF ANY UTILITY EASEMENTS TO | | | ENSURE THAT THERE WILL ALWAYS BE A BUFFER IN THE EVENT | | | THAT THE UTILITY HOLDER FORCES THE REMOVAL OF LANDSCAPE | | | FROM THE EASEMENT. STAFF DOES NOT SUPPORT. | | | PERIMETER PARCEL BUFFER LANDSCAPING: EACH INDIVIDUAL | | | PARCEL SHALL PROVIDE A MINIMUM OF A CONTINUOUS HEDGE | | | MATERIAL PLANTED 24 INCHES IN HEIGHT AROUND THE | | | PERIMETER OF EACH PARCEL EXCEPT WHEN ADJACENT TO AN | | | EXISTING WATER BODY, I-95 RIGHT-OF-WAY OR INTERNAL | | | PARCEL. ***** STAFF WILL NOT SUPPORT HAVING A CODE | | | COMPLIANT 36 INCH HIGH HEDGE AROUND THE ENTIRE | | | PERIMETER OF THE SITE. | | | PCD LANDSCAPE BUFFER: A MINIMUM FIVE (5) FOOT | | | LANDSCAPED BUFFER SHALL BE PROVIDED AROUND THE | | | PERIMETER OF THE ENTIRE PCD. ***** THIS IS STAFF?S | | | POSITION BUT IS CONTRADICTED BY AN EARLIER REGULATION | | | YOU PROPOSED. | | | MAXIMUM LOT COVERAGE: EACH INDIVIDUAL PARCEL SHALL BE | | | PERMITTED A MAXIMUM LOT COVERAGE OF %. THE OVERALL | | | MAXIMUM PCD LOT COVERAGE SHALL NOT EXCEED %. ***** | | | STAFF IS UNABLE TO RESPOND SINCE NO INFORMATION | | | PROVIDED. STAFF COULD SUPPORT ITS PREVIOUS POSITION: | | | MAXIMUM LOT COVERAGE BY BUILDINGS: 60 PERCENT FOR THE | | | ENTIRE BRANDSMART COMMERCIAL PLANNED DEVELOPMENT; | | | HOWEVER INDIVIDUAL PARCELS MAY HAVE UP TO 75 PERCENT | | | LOT COVERAGE BY BUILDINGS. | | | EASEMENTS: EASEMENTS SHALL NOT BE USED TO MEET THE | | | MINIMUM LANDSCAPE BUFFER REQUIREMENTS. ***** THIS IS | | | STAFF?S POSITION BUT IS CONTRADICTED BY AN EARLIER | | | REGULATION YOU PROPOSED. | | | FOUNDATION PLANTINGS: FOUNDATIONS PLANTINGS SHALL BE | | | REQUITED AND CAN BE APPROVED FOR EACH PARCEL ON A CASE | | | BY CASE BASIS. ***** THE 30% FOUNDATION PLANTING MUST | | | BE MET FOR ALL BUILDINGS AS PART OF THE REDEVELOPMENT. | | | PARCEL SETBACKS: ALL NEW CONSTRUCTION SHALL CONFORM TO | | | THE APPLICABLE SETBACKS AS CONTAINED WITHIN THE GENERAL | | | COMMERCIAL (GC) ZONING DISTRICT. ***** STAFF AGREES. | | | GENERAL SETBACKS: ALL PARCELS WITH THE PCD SHALL COMPLY | | | WITH THE GENERAL COMMERCIAL (GC) ZONING DISTRICT | | | SETBACKS BASED UPON THE FRONTAGE ESTABLISHED ON THE | | | MASTER PLAN. ***** STAFF AGREES. | | | CROSS PARKING: A CROSS PARKING EASEMENT IS CREATED FOR | | | THE ENTRE POA. THE OVERALL MINIMUM NUMBER OF PARKING | | | SPACES SHALL BE MAINTAINED FOR ALL COMBINED USES | | | CONTAINED WITHIN THE PCD. ***** STAFF AGREES. | | | BUILDING HEIGHT: EACH INDIVIDUAL PARCEL SHALL BE | | | PERMITTED A MAXIMUM BUILDING HEIGHT OF FIFTY (50) FEET. | | | PARCEL ONE (1) SHALL BE EXEMPT FROM THE THIS STANDARD | | | UNLESS AND UNTIL PARCEL 1 IS REDEVELOPED. ***** STAFF | | | DOES NOT UNDERSTAND WHAT IS BEING REQUESTED HERE. THE | | | PROPOSED BJ'S (SITE A1) IS OVER 50 FEET IN HEIGHT. | | | FLOOR AREA RATIO: THE MAXIMUM OVERALL PCD FLOOR AREA | | | RATIO (FAR) IS 1.0. NO INDIVIDUAL PARCEL SHALL EXCEED | | | AN FAR OF 2.0. ***** WHILE THIS MIRRORS THE PREVIOUS | | | DEVELOPMENT STANDARD THAT STAFF SUPPORTED, THE PREVIOUS | | | SUPPORT WAS BASED ON THE MITIGATION PROVIDED FOR THE | | | REQUESTED WAIVER TO THE INDIVIDUAL PARCEL LANDSCAPE | | | MINIMUM. THE DESIGN OF THE SITE DOES NOT JUSTIFY STAFF | | | SUPPORT OF THIS WAIVER REQUEST. | | | GENERAL PCD STANDARDS: ANY DEVELOPMENT REGULATIONS NOT | | | SPECIFICALLY IDENTIFIED HEREIN SHALL COMPLY, TO THE | | | GREATEST EXTENT POSSIBLE, TO THE GENERAL COMMERCIAL | | | (GC) ZONING REGULATIONS. ***** STAFF AGREES. | | | | | | 50) NOTE: NO WAIVER FOR PARKING BACKING INTO STREET | | | SINCE NOT ROW PARCEL BEING PROPOSED. ALL 3 PARCELS AS | | | DESIGNED FRONT ON AN ROW SO NO INTERNAL ROW PARCEL IS | | | REQUIRED. | | | | | | 51) NO BICYCLE PARKING WAS PROVIDED TO MEET CODE FOR | | | THE PARKING SPACES PROVIDED. | | | | | | | | | |
|
|
| |
Print |
|