Plan Review Details - Project Z20060015
Plan Review Stops For Project Z20060015
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 11-12-2020 Cont ID  
Sent By rbrown Date 11-12-2020 Time 16:23 Rev Time 0.00
Received By rbrown Date 11-12-2020 Time 16:23 Sent To  
Notes
2020-11-12 16:26:21DEVELOPMENT SERVICES DEPARTMENT, BUILDING DIVISION,
 COMMENTS:
  
 THIS REVIEW IS A CURSORY REVIEW AS IT RELATES TO THE
 SITE. IT IS NOT A REVIEW FOR FULL COMPLIANCE WITH
 FLORIDA BUILDING CODE.
  
 REVIEW PASSED. THE FOLLOWING COMMENTS ARE TO BE
 ADDRESSED FOR THE BUILDING PERMIT APPLICATION:
  
 1. BUILDING SIZE. WHEN SUBMITTED FOR BUILDING PERMIT,
 THE PLANS SHALL SHOW THAT THE TYPE OF CONSTRUCTION FOR
 THE BUILDINGS WILL BE IN ACCORDANCE WITH THE HEIGHT,
 AREA AND OCCUPANCY LIMITATIONS IN CHAPTER 5 OF THE
 FLORIDA BUILDING CODE.
  
 2. SEPARATE PERMITS REQUIRED. ALL APPLICABLE PERMITS
 AND SUB-PERMITS MUST BE OBTAINED BEFORE COMMENCING THE
 WORK. SEPARATE PERMITS, PLANS AND FEES, ARE REQUIRED
 FOR SIGNS, GAS SYSTEMS, GENERATORS, FIRE ALARM SYSTEMS,
 FIRE SPRINKLER AND OTHER FIRE SUPPRESSION SYSTEMS,
 GREASE INTERCEPTORS, SITE LIGHTING, SITE LANDSCAPE,
 SITE IRRIGATION, ETC.
  
 3. CONTRACTOR VEHICLE PARKING. PROPERTY OWNER AND
 CONTRACTOR SHALL MAKE ARRANGEMENTS FOR PARKING OF
 CONTRACTOR VEHICLES TO MINIMIZE THE IMPACT ON ALL
 NEIGHBORING PROPERTIES.
  
 4. PROTECTION OF NEIGHBORING PROPERTY. PROPERTY OWNER
 AND CONTRACTOR SHALL PROTECT ALL NEIGHBORING PROPERTY,
 INCLUDING VEHICLES, FROM DAMAGE OR DIRT CAUSED BY THE
 CONSTRUCTION, AND SHALL NOTIFY THE OCCUPANTS OF
 NEIGHBORING PROPERTIES ABOUT ALL STAGES OF CONSTRUCTION
 THAT MAY AFFECT THE USE OF THEIR PROPERTY.
  
 5. BUILDING ADDRESS. EACH SEPARATE BUILDING, AND UNIT
 WITH AN INDEPENDENT ENTRANCE FROM THE STREET, SHALL
 HAVE A SEPARATE ADDRESS. FOR STREET ADDRESSING, CONTACT
 CAROLINE PUELL, ADDRESSING COORDINATOR, AT (561) 805
 6659, OR BY EMAIL: [email protected]
  
  
 ROBERT BROWN
 BUILDING OFFICIAL
 TEL: 561 805 6652
 EMAIL: [email protected]
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 11-12-2020 Cont ID  
Sent By rbrown Date 09-18-2020 Time 19:55 Rev Time 0.00
Received By rbrown Date 09-18-2020 Time 19:55 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 07-08-2020 Cont ID  
Sent By rbrown Date 07-08-2020 Time 20:04 Rev Time 0.00
Received By rbrown Date 07-08-2020 Time 20:04 Sent To  
Notes
2020-07-08 20:12:27DEVELOPMENT SERVICES DEPARTMENT, BUILDING DIVISION,
 COMMENTS:
  
 1. THIS REVIEW IS A CURSORY REVIEW AS IT RELATES TO THE
 SITE. IT IS NOT A REVIEW FOR FULL COMPLIANCE WITH
 FLORIDA BUILDING CODE. THE FOLLOWING COMMENTS ARE TO BE
 ADDRESSED FOR THE BUILDING PERMIT APPLICATION.
  
 2. LOCATION OF ACCESSIBLE PARKING SPACES. TWO
 ACCESSIBLE PARKING SPACES ARE REQUIRED. SITE PLAN SHEET
 A1.1 SHOWS ONE OF THE PROPOSED ACCESSIBLE PARKING
 SPACES LOCATED AROUND 200 FEET FROM THE BUILDING
 ENTRANCE. THE ACCESSIBLE PARKING SPACE SHOULD BE
 LOCATED SO THAT IT IS THE CLOSEST PARKING SPACE TO THE
 BUILDING ENTRANCE. PER SECTION 208.3 OF FLORIDA
 ACCESSIBILITY CODE, ACCESSIBLE PARKING SPACES ARE TO BE
 LOCATED ON THE SHORTEST POSSIBLE ROUTE OF TRAVEL FROM
 ADJACENT PARKING TO AN ACCESSIBLE ENTRANCE. THE DESIGN
 OF ACCESSIBLE PARKING SPACES SHALL COMPLY WITH SECTION
 502 OF FLORIDA ACCESSIBILITY CODE
  
 3. BUILDING SIZE. WHEN SUBMITTED FOR BUILDING PERMIT,
 THE PLANS SHALL SHOW THAT THE TYPE OF CONSTRUCTION FOR
 THE BUILDINGS WILL BE IN ACCORDANCE WITH THE HEIGHT,
 AREA AND OCCUPANCY LIMITATIONS IN CHAPTER 5 OF THE
 FLORIDA BUILDING CODE.
  
 4. SEPARATE PERMITS REQUIRED. ALL APPLICABLE PERMITS
 AND SUB-PERMITS MUST BE OBTAINED BEFORE COMMENCING THE
 WORK. SEPARATE PERMITS, PLANS AND FEES, ARE REQUIRED
 FOR SIGNS, GAS SYSTEMS, GENERATORS, FIRE ALARM SYSTEMS,
 FIRE SPRINKLER AND OTHER FIRE SUPPRESSION SYSTEMS,
 GREASE INTERCEPTORS, SITE LIGHTING, SITE LANDSCAPE,
 SITE IRRIGATION, ETC.
  
 5. CONTRACTOR VEHICLE PARKING. PROPERTY OWNER AND
 CONTRACTOR SHALL MAKE ARRANGEMENTS FOR PARKING OF
 CONTRACTOR VEHICLES TO MINIMIZE THE IMPACT ON ALL
 NEIGHBORING PROPERTIES.
  
 6. PROTECTION OF NEIGHBORING PROPERTY. PROPERTY OWNER
 AND CONTRACTOR SHALL PROTECT ALL NEIGHBORING PROPERTY,
 INCLUDING VEHICLES, FROM DAMAGE OR DIRT CAUSED BY THE
 CONSTRUCTION, AND SHALL NOTIFY THE OCCUPANTS OF
 NEIGHBORING PROPERTIES ABOUT ALL STAGES OF CONSTRUCTION
 THAT MAY AFFECT THE USE OF THEIR PROPERTY.
  
 7. BUILDING ADDRESS. EACH SEPARATE BUILDING, AND UNIT
 WITH AN INDEPENDENT ENTRANCE FROM THE STREET, SHALL
 HAVE A SEPARATE ADDRESS. FOR STREET ADDRESSING, CONTACT
 CAROLINE PUELL, ADDRESSING COORDINATOR, AT (561) 805
 6659, OR BY EMAIL: [email protected]
  
  
 ROBERT BROWN
 BUILDING OFFICIAL
 TEL: 561 805 6652
 EMAIL: [email protected]
  
  

Review Stop ENG - PPRC ENGINEERING - PPRC
Rev No 3 Status P Date 10-19-2020 Cont ID  
Sent By rrossano Date 10-19-2020 Time   Rev Time 0.00
Received By rrossano Date 10-19-2020 Time   Sent To  
Notes
2020-10-19 13:55:21PASSED WITH PROVISOS:
  
 ZONING APPROVAL IS NECESSARY PRIOR TO FORMAL
 ENGINEERING SUBMITTAL.
  
 THE FOLLOWING COMMENTS ARE FROM MARK HURLEY, FIELD
 CUSTOMER SERVICE SUPERVISOR, WPB PUBLIC UTILITIES,
 PLEASE CONTACT 561-494-2262 OR [email protected]:
  
 SHEET C-11
 -REPLACE STANDARD DETAIL WS-8 WITH WS-1. (METER BOXES
 NOT IN SIDEWALKS)
 -REMOVE WS-12. (NOT NEEDED AS INSTALLING RP?S AND WS-6
 ALREADY INCLUDED)
 -#2 ON ENLARGED PLAN SAYS USE EXISTING BOX FOR 1.5 IN.
 METER, BUT THE BOX IS TOO SMALL FOR THAT. WOULD HAVE TO
 REPLACE WITH BIGGER FLARED WALL METER BOX THAT HAS 17
 IN. X 30 IN. LID. (NEED TO ALSO UPDATE SIMILAR NOTES ON
 SHEET C-6)
  
 SHEET C-6
 -IS THE MILLING AND RESURFACING ON AUSTRALIAN AV. JUST
 FOR THE FIRE HYDRANT INSTALLATION ON THE WATER MAIN? IF
 SO, THEN IT MAY NOT BE NEEDED IF THE WATER MAIN IS
 FOUND TO BE IN THE MIDDLE OF THE GRASS PARKWAY INSTEAD
 OF ON EDGE OF ROAD. COULD ADD NOTE TO VERIFY IF IT
 REQUIRED AFTER FIRE HYDRANT INSTALLATION IS COMPLETE.
 -PLAN DOES NOT SHOW NUMERICAL PROPERTY ADDRESS AND DOES
 NOT HAVE A RECENT REVISION DATE. PLEASE ADD TO FORMAL
 ENGINEERING SUBMITTAL.
 -THE MIDDLE WATER SERVICE OF THREE IS NOT DRAWN. PLEASE
 ADD TO FORMAL ENGINEERING SUBMITTAL.
  
 ADDITIONAL COMMENTS FROM OCT 7 2020 ZOOM MEETING WITH
 LAURA LE, SUZANNE BERGLUND, TRACY WARD, DANA GILLETTE,
 STEPHON HARRIS TO BE ADRESSED WITH NEXT SUBMITTAL:
  
 SEWER
 1. THE CLEAN OUT SHOULD BE MOVED TO BEHIND THE SIDEWALK
 WITH A CONCRETE COLLAR.
 2. THE SEWER LATERAL SHOULD BE LINED DUE TO A CRACK IN
 THE PIPE NEAR THE MANHOLE. SUZANNE WILL PROVIDE THE
 CITY STANDARD SPEC.
 3. ADD A NOTE THAT THE CONTRACTOR IS TO COORDINATE WITH
 THE CITY UTILITY DEPT FOR WORK ON THE CITY?S WATER AND
 SEWER LINES.
 4. ADD A NOTE THAT THE CONTRACTOR IS TO OBTAIN A POST
 CONSTRUCTION CCTV OF THE SEWER LATERAL.
 5. THERE IS AN UNKNOWN UTILITY LINE. ADD A NOTE THAT
 THE CONTRACTOR IS TO LOCATE ALL PIPES/UTILITIES THAT
 ARE DISCOVERED/ CROSSED AND PROVIDE THEIR LOCATION ON
 THE AS BUILTS.
 6. ADD THE RIGHT OF WAY LINE TO THE PLANS.
 7. ADD A UTILITY EASEMENT AROUND THE NEW CLEAN OUT.
 8. LAURA NOTED THAT THERE IS A FORCE MAIN ON THE SOUTH
 SIDE OF 15TH ST, BUT THAT IT IS OUTSIDE OF THE PROPOSED
 WORK AREA.
  
 WATER SERVICE
 9. DANA NOTED THAT SHE?S BEEN COORDINATING WITH MARK
 HURLEY ABOUT THE WATER SERVICE CONFIGURATION. LAURA
 NOTED THAT IF THE 4? LINE, OR ANY OF THE THREE
 SERVICES, HAS AN ISSUE THEN ALL THREE SERVICES WILL BE
 IMPACTED. DANA NOTED THAT SINCE TWO ARE IRRIGATION
 LINES, THEY CAN BE TAKEN OUT OF SERVICE WITHOUT SERIOUS
 IMPACT.
 10. ADD THE FOLLOWING TO THE WATER SERVICE SKETCH:
 MATERIAL OF THE 4? PIPE (CAST IRON), LOCATION OF THE
 CAP, LOCATION OF THE 1? COPPER, NOTE TO CAP THE 1?
 COPPER AT THE MAIN, NOTE THAT THE AS-BUILTS ARE TO
 INCLUDE DETAILS OF THE SERVICE SKETCH AND ANY CAPPED
 LINES.
 11. ADD TO THE TABLE HOW WE DID THE MATH TO DETERMINE
 THE FLOW FOR THE WATER AND SEWER.
  
  
 FEEL FREE TO CONTACT US IF YOU HAVE ANY QUESTIONS OR
 CONCERNS, THANKS.
 RICK ROSSANO, PROJECT COORDINATOR, ENGINEERING SERVICES
 DEPARTMENT
 DIRECT: (561) 494-1098 [email protected]
  
  

Review Stop ENG - PPRC ENGINEERING - PPRC
Rev No 2 Status F Date 08-27-2020 Cont ID  
Sent By rrossano Date 08-27-2020 Time   Rev Time 0.00
Received By rrossano Date 08-27-2020 Time   Sent To  
Notes
2020-08-27 12:47:06THE FOLLOWING COMMENTS ARE FROM MARK HURLEY, FIELD
 CUSTOMER SERVICE SUPERVISOR, WPB PUBLIC UTILITIES,
 PLEASE CONTACT 561-494-2262 OR [email protected]:
  
 FOLLOWUP COMMENTS CONCERNING SHEET C-06:
 WATER SERVICES AND METERS APPEAR TO STILL NOT BE
 ACCURATE RELATED TO EXISTING CONDITIONS ON SITE. THE
 EASTERN EXISTING METER HAS NO DAMAGE (I THINK THE BOX
 WAS REPLACED RECENTLY) AND IS THE ? IN. METER
 HISTORICALLY USED FOR DOMESTIC WATER AT THE PROPERTY.
 THAT METER COULD NOT BE UPGRADED TO 2 IN. AS THE
 SERVICE LINE IS SMALL. THE WESTERN EXISTING METER AT
 SOUTH END OF PROPERTY IS THE PARKS DEPARTMENT 1.5 IN.
 IRRIGATION METER THAT MR. KRISCHE ADVISED IN JULY 2020
 NEEDED TO REMAIN IN TACT FOR FUTURE USE ? ONLY LABEL
 ?PARK DEPARTMENT TO REMOVE? IF PARKS REPRESENTATIVE
 ADVISED THAT WAS THEIR INTENTION. TO INCREASE THE ? IN.
 DOMESTIC METER TO 1.5 IN., THE SMALL SERVICE LINE WOULD
 HAVE TO BE REPLACED WITH A 2 IN. SERVICE LINE PER WATER
 SERVICE STANDARD DETAILS AND APPROVED MATERIAL LIST.
 -THE EXISTING PVB BACKFLOW ASSEMBLY FOR THE EXISTING
 PARKS IRRIGATION METER IS THEIR PROPERTY. APPROVAL
 WOULD NEED TO BE OBTAINED PARKS REPRESENTATIVES TO
 REMOVE IT. THE ASSEMBLY COULD NOT BE RELOCATED AND
 REUSED AS A CONTAINMENT BACKFLOW ASSEMBLY IN OUR WATER
 SERVICE AREA.
  
 FEEL FREE TO CONTACT US IF YOU HAVE ANY QUESTIONS OR
 CONCERNS, THANKS.
 RICK ROSSANO, PROJECT COORDINATOR, ENGINEERING SERVICES
 DEPARTMENT
 DIRECT: (561) 494-1098 [email protected]
  

Review Stop ENG - PPRC ENGINEERING - PPRC
Rev No 1 Status F Date 07-07-2020 Cont ID  
Sent By rrossano Date 07-07-2020 Time   Rev Time  
Received By rrossano Date 07-07-2020 Time   Sent To  
Notes
2020-07-07 15:41:071. PLEASE RESPOND TO ALL COMMENTS IN WRITING, AND
 INCLUDE PROJECT NAME, ADDRESS AND PERMIT NUMBER
 (Z-XXXXXXXX).
 2. THE CITY OF WEST PALM BEACH HAS A NUMBER OF
 REGULATIONS AND PERMIT REQUIREMENTS WHICH DIRECTLY
 AFFECT THE DEVELOPMENT AND INSTALLATION OF WATER AND
 WASTEWATER UTILITIES WITHIN THE CITY. PLEASE SEE
 DEVELOPMENT PERMIT SUBMITTAL REQUIREMENTS AT THE LINK
 BELOW:
 HTTP://WPB.ORG/CMSPAGES/GETAMAZONFILE.ASPX?PATH=~\WPB_W
 EBSITE\MEDIA\ENGINEERING\DEVELOPMENT-APPLICATION-FULL-P
 ACKAGE_2016.PDF&HASH=7BD4DD7EB6115181D8C5977BCC02A97B19
 60045731D3658206F27451722716EF
 THIS AND OTHER RELATED ENGINEERING DOCUMENTS CAN BE
 FOUND HERE:
 HTTP://WPB.ORG/DEPARTMENTS/ENGINEERING-PUBLIC-WORKS/FOR
 MS,-PERMITS-APPLICATIONS
 ALSO SEE: CODE OF ORDINANCES, CITY OF WEST PALM BEACH,
 FLORIDA, CODIFIED THROUGH ORD. NO. 4183-08, ADOPTED
 SEPT. 22, 2008. (SUPPLEMENT NO. 18)
 CHAPTER 90 UTILITIES, ARTICLE I. IN GENERAL,
 SEC. 90-7. POLICY REGARDING EXTENSION OF WATER OR SEWER
 SERVICE FACILITIES OF THE CITY.
 3. THE WATER AND WASTEWATER SERVICE AGREEMENTS AND THE
 CONSTRUCTION PERMITS ADDRESS RESERVATION OF CAPACITY
 BASED ON USAGE, METER SIZE AND FEES, DESIGN STANDARDS,
 BACKFLOW PREVENTION, FIRE SERVICE AND IRRIGATION.
 4. PLEASE SUBMIT A FORMAL AS-BUILT REQUEST FOR ALL CITY
 OF WEST PALM BEACH-OWNED UTILITIES WITHIN THE PUBLIC
 RIGHT OF WAY FOR THE ENTIRE EXTENT OF THE LIMITS OF
 YOUR PROJECT. IDENTIFY TYPE OF UTILITY, LOCATION, PIPE
 MATERIAL, AGE AND SIZE. PLEASE CONTACT JANICE TARBILL
 IN THE WPB ENGINEERING SERVICES DEPARTMENT AT
 [email protected] OR 561-494-1079 FOR FURTHER
 ASSISTANCE. NOTE THAT FIELD RECORDS ARE FOR INFORMATION
 ONLY. FIELD VERIFY UTILITY LOCATIONS USING FIELD
 SURVEY, POT-HOLING, SOFT DIGS ETC.
 5. AS OF DECEMBER 20, 2015, THE CITY OF WEST PALM BEACH
 CROSS-CONNECTION CONTROL MANUAL HAS BEEN REVISED,
 STATING "ALL BACKFLOW DEVICES MUST BE LEAD-FREE". FOR
 MORE INFORMATION, REFER TO THE LINK BELOW:
 HTTP://WPB.ORG/DEPARTMENTS/PUBLIC-UTILITIES/FORMS-PUBLI
 CATIONS/BACKFLOW-CROSS-CONNECTION-CONTROL-MANUAL
 6. PLANS SHALL SHOW PROPOSED LOCATIONS AND DIMENSIONS
 OF ALL WATER, STORM WATER, AND SANITARY AND SEWER
 LINES, INCLUDING STUBS TO EACH PROPERTY LINE FOR WATER
 AND SANITARY SEWERS, THE MAKE AND MODEL OF ALL VALVES,
 METERS, AND OTHERS DEVICES TO BE INSTALLED ON THE
 SYSTEM, CATCH BASINS, CULVERTS, DITCHES INCLUDING
 GRADES, PIPES SIZES, MATERIALS, ELEVATIONS,
 ASSUMPTIONS, CALCULATIONS, INVERT ELEVATIONS FOR ALL
 INLETS AND MANHOLES AND PROFILES OF SANITARY SEWER
 LINES. ALL AVAILABLE ELEVATION SHALL BE SHOWN ON THE
 PROFILE VIEW. DIRECTION OF FLOW SHALL BE SHOWN ON PLAN
 VIEW ON PLAN VIEW FOR ALL SANITARY AND STORM SEWERS.
 ADDITIONALLY, PLAN VIEW SHALL SHOW ALL EXISTING AND
 PROPOSED UNDERGROUND UTILITY LAYOUT, INCLUDING FIBER
 OPTIC, ELECTRIC, GAS, AND CABLEVISION &
 TELECOMMUNICATION FACILITIES LOCATED ON THE
 RIGHT-OF-WAY. PROVIDE PROFILE AND CLEARANCES AT ALL
 UTILITY CROSSINGS. CUT AND CAP UTILITIES NOT IN USE,
 AND REMOVE ANY ABANDONED UTILITY LINES LARGER THAN 2
 INCHES FROM CITY RIGHT OF WAY.
 7. PLEASE SUBMIT COMPLETED LOS ANALYSIS SUMMARY TABLE
 DIRECTLY TO ENGINEERING (SHEET 33 OF CITY OF WPB
 DEVELOPMENT APPLICATION).
 8. WHEN PROPOSED, WATER MAINS IN CITY RIGHT OF WAY
 SHALL BE MADE OF DUCTILE IRON PIPE (NOT PVC) AND
 SPECIFY PROPOSED LENGTH IN FEET.
 9. PLEASE COORDINATE PLACEMENT OF WATER METERS/BACKFLOW
 PREVENTION ETC. WITH MARK HURLEY OF PUBLIC UTILITIES
 CUSTOMER SERVICE AT 561-822-2262 OR [email protected].
 10. PLEASE CALLOUT DOMESTIC BACKFLOW PREVENTER AS RPPA
 AND FIRE BACKFLOW PREVENTER AS DCDA.
 11. PLEASE PROVIDE ENLARGED VIEW ON PLANS OF PROPOSED
 LOCATION OF WATER METER AND BACKFLOW PREVENTION.
 12. PROVIDE VERTICAL DATUM AND DATUM CONVERSION
 INFORMATION (NAVD 1988 AND NGVD 1929).
 13. PROVIDE CALCULATIONS ON PLANS OF EXISTING AND
 PROPOSED DEMANDS FOR WATER & SEWER (AVERAGE, MAXIMUM
 AND PEAK) AND FIRE FLOW DEMANDS. CALCULATIONS SHALL BE
 PER FAC 64E-6 FOR SEWER AND PER FAC 64-E.008 FOR WATER.
 14. PROVIDE CCTV VIDEO OF EXISTING SANITARY SEWER AND
 STORMWATER INFRASTRUCTURE ALONG ENTIRE PROJECT
 FRONTAGE.
 15. CHECK TO SEE IF FDEP FORMS FOR PROPOSED SANITARY
 SEWER ARE REQUIRED.
 16. PLEASE PROVIDE CLEANOUTS FOR PROPOSED SANITARY LINE
 ONSITE JUST INSIDE PROPERTY LINE, AT JOINTS AND EVERY
 75 FEET.
 17. FOR FORMAL ENGINEERING SUBMITTAL, SFWMD ERP AND
 NPDES NOI REQUIREMENTS WILL BE ENFORCED.
 - AN NOI IS REQUIRED FOR PROJECTS THAT:
 - 1) DISTURB ONE OF MORE ACRES OF LAND OR DISTURB LESS
 THAN ON ACRE OF LAND BUT ARE PART OF A COMMON PLAN OF
 DEVELOPMENT OR SALE;
 - 2) DISCHARGE STORMWATER TO SURFACE WATERS OF THE
 STATE OR TO SURFACE WATERS OF THE STATE THROUGH A
 MUNICIPAL SEPARATE STORM SEWER SYSTEM (MS4).
 - THE SFWMD ERP CAN BE OBTAINED THROUGH A 10-2 SELF
 CERTIFICATION THROUGH FDEP OR AN ERP APPLICATION
 THROUGH SFWMD. EITHER WAY, THE DEVELOPER/ENGINEER SHALL
 SUBMIT A COPY OF THE ERP PERMIT OR FDEP ACKNOWLEDGEMENT
 OF THE 10-2 CERTIFICATION.
 18. FOR FORMAL ENGINEERING SUBMITTAL, PLEASE PROVIDE
 EASEMENT FOR PLACEMENT OF PROPOSED WATER METERS.
 19. FOR FORMAL ENGINEERING SUBMITTAL, PROVIDE PROFILES
 OF WATER AND SEWER AND SHOW ANY CROSSINGS/CONFLICTS.
 20. FOR FORMAL ENGINEERING SUBMITTAL, WHEN SUBMITTING
 APPROVED MATERIALS LIST, PLEASE PROVIDE MATERIAL/CUT
 SHEETS FOR ALL PROPOSED BACKFLOW DEVICES SHOWING
 SPECIFIC MODEL NUMBER AND SPECIFYING USC APPROVED
 LEAD-FREE DESIGN.
 21. FOR FORMAL ENGINEERING SUBMITTAL, IF SANITARY LINES
 ARE PROPOSED IN ROW PLEASE SHOW ADJACENT SANITARY
 LATERAL LOCATIONS AND SHOW ADDRESSES OF ADJACENT
 PARCELS.
 22. FOR FORMAL ENGINEERING SUBMITTAL, IF WATER LINES
 ARE BEING REPLACED IN ROW, SHOW ADJACENT PARCEL
 ADDRESSES.
 23. FOR FORMAL ENGINEERING SUBMITTAL, ADD NOTE TO
 PROVIDE 50 FT. PAVEMENT RESTORATION TRANSITION ON EACH
 SIDE OF PROPOSED TRENCH IN CITY MAINTAINED ROADWAY
 AREAS PER CITY OF WPB STANDARD DETAIL GC-8.
 24. FOR FORMAL ENGINEERING SUBMITTAL, SHOW DIMENSIONS
 OF PROPOSED DUMPSTER PER CURRENT CITY OF WPB STANDARD
 DETAIL GC-7.
 25. FOR FORMAL ENGINEERING SUBMITTAL, PLEASE PROVIDE
 CALCULATIONS OF PERVIOUS AND IMPERVIOUS AREAS FOR
 PROPOSED IMPROVED AREAS.
  
 THE FOLLOWING COMMENTS ARE FROM HONG XU, PROJECT
 ENGINEER, PUBLIC UTILITIES, 561-494-1047, [email protected]:
  
 NEED TO SHOW WATER SERVICE AND SANITARY SEWER LATERAL
 CONNECTIONS ON THE PLAN. IT SAYS SEE PLUMBING PLANS FOR
 CONNECTIONS. BUT THE PLUMBING PLANS ARE NOT PROVIDED IN
 THE SUBMITTAL.
 FEEL FREE TO CONTACT US IF YOU HAVE ANY QUESTIONS OR
 CONCERNS, THANKS.
  
 ADDITIONAL COMMENTS ADDED JULY 13, 2020 FROM MARK
 HURLEY, CUSTOMER SERVICE SUPERVISOR, CITY OF WPB PUBLIC
 UTILITIES, [email protected], 561-822-2262:
  
 -THE OLD METER FOR THE PROPERTY IS 3/4 IN. AND ACCOUNT
 IS NOT ACTIVE. PLAN DESIGNER WOULD NEED TO DETERMINE IF
 THE 3/4 IN. METER WILL BE SUFFICIENT FOR THE WATER
 DEMAND OR IF IT NEEDS TO BE UPSIZED TO 1 IN. METER.
 WILL HAVE TO WORK WITH OUR UTILITY BILLING DEPT TO
 DETERMINE THE COSTS INVOLVED EITHER WAY.
 -PLEASE ADD WATER DEMAND CALCULATIONS TO PLAN.
 -THE 2 IN. LINE CURRENTLY HAS A 1.5 IN. METER. IT LOOKS
 TO BE AN ACTIVE PARKS IRRIGATION METER. WE WOULD HAVE
 TO VERIFY WITH PARKS IF THEY ARE USING IT AND WHAT IT
 SERVES (MAY WATER THE ROW GRASS). IF IT IS NOT
 AVAILABLE, THEN MAY HAVE TO GET NEW LINE, TAP, & METER.
 IF AVAILABLE PLAN DESIGNER WOULD NEED TO DETERMINE IF
 1.5 IN. METER IS SUFFICIENT FOR DEMAND OR IF NEED
 UPSIZE TO 2 IN. METER. SAME WITH UTILITY BILLING.
 -PLAN DRAWINGS FOR THE WATER LINES DO NOT MATCH THE
 HISTORIC DRAWINGS WITH THE 4 IN. WATER MAIN BRANCH
 ACROSS 15TH ST AND E-W SERVICE LINES. THEY NEED TO BE
 VERIFIED IN THE FIELD AND PLAN UPDATED AS NEEDED.
 -PLEASE REFERENCE THE WS STANDARD DETAILS FOR THE
 BACKFLOW ASSEMBLIES AND USE RP TYPE ASSEMBLIES.
 DEPENDING ON METHOD, MAY HAVE TO BORE UNDER SIDEWALK OR
 CUT IT OUT TO PLACE NEW PIPING AND SLEEVE UNDER
 SIDEWALK.
 -LOOKS LIKE NEW HYDRANT BEING INSTALLED NEAR NW CORNER
 OF PROPERTY. NEED LABEL TO MAKE THAT MORE CLEAR AND THE
 TEE DOES NOT LOOK LIKE IT IS DRAWN ONTO THE CORRECT
 PIPING. PLEASE ALSO MOVE VALVE IN SIDEWALK EAST OUT OF
 THE SIDEWALK.
  
  
 RICK ROSSANO, PROJECT COORDINATOR, ENGINEERING SERVICES
 DEPARTMENT
 401 CLEMATIS STREET, 4TH FLOOR, WEST PALM BEACH, FL
 33401
 DIRECT: (561) 494-1098, FAX: (561) 494-1116, MOBILE:
 (561) 246-9525
 EMAIL: [email protected]
 WWW.WPB.ORG/ENGINEERING
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 07-02-2020 Cont ID  
Sent By pleduc Date 07-02-2020 Time   Rev Time 0.00
Received By pleduc Date 07-02-2020 Time 16:24 Sent To  
Notes
2020-07-02 16:28:03THE FOLLOWING COMMENTS WERE SUBMITTED BY PETER LEDUC,
 FIRE MARSHAL, BUREAU OF FIRE PREVENTION, WEST PALM
 BEACH FIRE RESCUE.
  
 THIS REVIEW CAN ONLY BE CONSIDERED PRELIMINARY AS THE
 DRAWINGS THAT WERE REVIEWED WERE NOT COMPLETE.
 ADDITIONAL COMMENTS CAN BE EXPECTED WHEN FULL DRAWINGS
 ARE SUBMITTED FOR PERMIT.
  
 THE FIRE PREVENTION BUREAU HAS NO OBJECTIONS TO THE
 PROPOSED PROJECT.
  
 1. CONSTRUCTION, DEMOLITION, AND RENOVATION TO COMPLY
 WITH NFPA 241. EXTRA ATTENTION SHALL BE GIVEN TO THE
 PERMITTING AND LOCATION OF CONSTRUCTION TRAILERS. A
 PERMIT IS REQUIRED FOR ANY CONSTRUCTION TRAILER RELATED
 TO THIS PROJECT. SEPARATION DISTANCES FROM MAIN
 STRUCTURES AS WELL AS OTHER TRAILERS SHALL BE CLOSELY
 MONITORED FOR THE REQUIREMENTS OF FIRE SPRINKLER
 PROTECTION.
  
 2. SITE ACCESS AND EXIT POINTS ARE TO BE CLEARLY
 IDENTIFIED AND MAINTAINED FOR EMERGENCY VEHICLES DURING
 ALL CONSTRUCTION ACTIVITIES.
  
 3. THE BUILDING ADDRESS SHALL BE CLEARLY VISIBLE FROM
 ALL ACCESS ROADWAYS, INCLUDING DURING CONSTRUCTION.
 ADDRESS NUMBERS SHALL CONTRAST WITH THEIR BACKGROUND
 AND SHALL NOT BE LESS THAN SIX (6) INCHES IN HEIGHT
 WITH A ONE (1) INCH STROKE FOR ALL BUILDINGS.
  
 4. DURING CONSTRUCTION, TRASH AND DEBRIS IS TO BE
 REMOVED FROM THE SITE DAILY OR MORE OFTEN TO REDUCE THE
 ACCUMULATION OF POTENTIAL LIFE AND FIRE SAFETY HAZARDS.
  
 5. THE CONSTRUCTION OF THE BUILDING SHALL COMPLY WITH
 THE 6TH EDITION OF THE FLORIDA FIRE PREVENTION CODE,
 INCLUDING NFPA 1 & 101, AND ALL ASSOCIATED FIRE CODES.
  
 6. FOR PLAN REVIEW SUBMITTAL, PLEASE INCLUDE THE
 OCCUPANCY TYPE, PER THE FLORIDA FIRE PREVENTION CODE.
  
 7. FOR PLAN REVIEW SUBMITTAL, PLEASE ENSURE THAT A FIRE
 LOAD CALCULATION IS INCLUDED AND THAT ADEQUATE WATER
 SUPPLY IS EXISTING OR WILL BE PROVIDED.
  
 8. ALL EXISTING AND NEW FIRE HYDRANTS PLANNED FOR THIS
 DEVELOPMENT SHALL BE CLEARLY INDICATED AND IDENTIFIED
 ON THE PLAN AND CLOSELY COORDINATED WITH THE BUREAU OF
 FIRE PREVENTION.
  
 THE PROPOSED LOCATIONS OF THE FIRE HYDRANT IS
 ACCEPTABLE WITH ANY CHANGES CLOSELY COORDINATED WITH
 THE BUREAU OF FIRE PREVENTION.
  
 9. PROVIDE FOR A FIRE SPRINKLER AND/OR FIRE ALARM PER
 THE APPLICABLE OCCUPANCY CODE. FOR ANY LIFE SAFETY
 ENGINEERED SYSTEM, I.E FIRE SPRINKLER AND FIRE ALARM,
 ENSURE THEY COMPLY WITH THE REQUIREMENTS OF FS 61G AND
 SUBMITTED WITH THE MASTER PERMIT.
  
 9A) THE LOCATION OF ANY APPLICABLE DDCV AND FIRE LINE
 LOCATIONS SHALL MEET THE REQUIREMENTS OF NFPA 24 AND
 SHALL BE COORDINATED WITH THE OFFICE OF FIRE MARSHAL,
 THE CITY'S ENGINEERS OFFICE, THE LANDSCAPE PLANNER, AND
 THE CITY'S PLANNING AND ZONING OFFICE.
  
 10. COMPLETE LIFE SAFETY PLANS FOR THE OCCUPANCY SHALL
 BE PROVIDED THAT ILLUSTRATE OCCUPANT LOADS, TRAVEL
 DISTANCES, COMMON PATHS OF TRAVEL, DEAD-END CORRIDORS,
 EXIT SIGNS, EMERGENCY LIGHTING, EXITS LEADING TO A
 PUBLIC WAY, FIRE EXTINGUISHER LOCATIONS, AND ALL FIRE
 SAFETY FEATURES AND EQUIPMENT.
  
 11. IT IS HIGHLY RECOMMENDED (REQUIRED WITH FIRE
 SPRINKLER SYSTEM) THAT A KNOX BOX WITH KEYS FOR ENTRY
 DOOR LOCKS BE PROVIDED FOR 24 HOUR EMERGENCY ACCESS.
  
 12. THE BUREAU'S APPROVAL OF THIS SUBMITTED PROJECT
 DOES NOT CONSTITUTE ITS FINAL REVIEW OR APPROVAL.
  
 13. THE BUREAU SHALL REVIEW ALL SUBMITTED BUILDING
 PLANS AT THE APPROPRIATE TIME AND IN ACCORDANCE WITH
 THE REQUIREMENTS OF ALL APPLICABLE CODES AND STANDARDS.
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]
  

Review Stop L LANDSCAPING
Rev No 4 Status P Date 11-03-2020 Cont ID  
Sent By rcaranci Date 11-03-2020 Time 14:21 Rev Time 0.00
Received By rcaranci Date 11-03-2020 Time 14:21 Sent To  
Notes
2020-11-03 14:21:29FROM: RAY CARANCI, SENIOR LANDSCAPE PLANNER
 561-822-1462
 PROJECT: 1600 N AUSTRALIAN Z20060015
 NOVEMBER 3, 2020
 I HAVE REVIEWED THE ABOVE REFERENCED PETITION, AND
 PROVIDE THE FOLLOWING COMMENTS:
  
  
 1. MAKE THE FOLLOWING CORRECTIONS TO THE TREE
 DISPOSITION PLAN SHEET 1 OF 1.
 ? SATISFIED. COLUMN FOR CONDITION MUST BE INCLUDED IN
 THE CHART.
 ? SATISFIED. GIVE THE CONDITION OF EACH TREE.
 ? SATISFIED. INCLUDE CANOPY DIAMETER MEASUREMENT FOR
 TREES IN ORDER TO CALCULATE MITIGATION DUE IF REMOVED.
 ? SATISFIED. CANOPY SQUARE FOOTAGE FOR MITIGATION DUE
 FOR ANY TREES PROPOSED FOR REMOVAL MUST BE IN A
 SEPARATE COLUMN, AND THE TOTAL PROVIDED FOR THE COLUMN.
 ? SATISFIED. REMOVALS OF PALMS MUST INCLUDE THE
 MITIGATION REQUIRED BY CATEGORY.
 QUEEN PALM 112 AND 5 CHINESE FAN PALMS ARE CATEGORY 4
 MITIGATION REQUIRED 50 SQ FT EACH FOR A TOTAL OF 300 SQ
 FT PLUS 706 FOR JACARANDA. TOTAL IS 1006 SQ FT. UPDATE
 CANOPY REPLACEMENT COLUMN AND TOTAL.
 ? SATISFIED. INCLUDE A CHART FOR TREE MITIGATION
 PROVIDED BASED ON THE PLANT LIST AND PROVIDE THE TOTAL
 FOR THE SQUARE FOOTAGE.
 INCLUDE ALL TREES ADDED ON LANDSCAPE PLAN AND TOTAL
 CANOPY SQ FT CREDIT.
  
 2. SATISFIED. SECTION 94-448 (D)(3) REQUIRES NATIVE
 TREES IN GOOD CONDITION TO BE PRESERVED ON SITE OR
 RELOCATED. ANSI A 300 (PART 5) STANDARDS SPECIFY
 EXAMPLES OF SUITABILITY RATINGS OF GOOD, MODERATE, OR
 POOR FOR RELOCATION. PROVIDE CONDITION AND RELOCATION
 POTENTIAL FOR THE NATIVE SABAL PALMS.
  
 3. SATISFIED. CITY POLICY REQUIRES THE USE OF FLORIDA
 NATIVE SPECIES WHEN POSSIBLE. THERE ARE NATIVE
 ALTERNATIVES FOR CARRISSA, PODOCARPUS, AND PITTOSPORUM.
  
 IT WOULD BE BETTER TO HAVE 100% NATIVE IF POSSIBLE.
 PREFERRED TO HAVE SPECIES THAT REQUIRE NO FERTILIZER
 BECAUSE THEY WILL NOT RECEIVE IT.
  
 4. SATISFIED. CHECK THE FLORIDA FRIENDLY DESIGN OPTIONS
 LIST AND SEE IF MORE POINTS CAN BE ADDED THROUGH NATIVE
 TREES AND SHRUBS. THE ADDITIONAL SHADE TREES IN
 VEHICULAR USE AREAS MUST BE VERIFIED IF CLAIMED.
 PLEASE TAKE CREDITS FOR NATIVE TREES AND SHRUBS FIRST.
  
 5. SATISFIED. ADJUST THE CALCULATIONS FOR MINIMUM SHADE
 TREE AND FLOWERING TREE REQUIREMENTS PER SECTION
 94-443(C)(2)B. BASED ON REQUIRED OPEN SPACE OF 14793 SQ
 FT. SHADE TREES-10, FLOWERING TREES -3, SHRUBS -30.
 FLOWERING TREE CATEGORY IS MISSING.
  
 6. SATISFIED. ADD RELOCATED PALMS TO THE PLANT LIST AND
 COUNT THEM TOWARD THE REQUIRED TREES.
  
 NOT CLEAR IF SABALS LABELED EXISTING ARE RELOCATED. ADD
 THE OTHER EXISTING TREES TO REMAIN TO THE PLANT LIST.
  
 7. SATISFIED. MINIMUM TREE SIZES ARE 12 FEET, AND PALMS
 8 FOOT CLEAR TRUNK. MAKE CORRECTIONS.
  
 8. SATISFIED. PROVIDE A PLAN SHOWING THE PARKING
 LANDSCAPE AREAS COUNTED TOWARD COMPLIANCE WITH SECTION
 94-443(C)(3) AND (4) AND PROVIDE CALCULATIONS.
 CALCULATE SQUARE FOOTAGE REQUIRED PER CODES REFERENCED
 AND SHOW WHERE IT IS PROVIDED WITHIN THE PARKING AREA.
  
 9. SATISFIED. SECTION 94-443(C)(3) REQUIRES THAT A
 MINIMUM OF 75 PERCENT OF ALL TREES THAT ARE REQUIRED TO
 BE PLANTED WITHIN THE INTERIOR OF AN OFF STREET PARKING
 AREA SHALL BE CATEGORY 1 SHADE TREES. SHOW THE
 PERCENTAGE OF CATEGORY 1 TREES PROVIDED FOR THE
 REQUIRED LANDSCAPE AREAS.
  
 10. SATISFIED. PROVIDE CALCULATIONS FOR REQUIRED BUFFER
 TREES AT ONE FOR EVERY 30 FEET OR PORTION THEREOF FOR
 EACH BUFFER LENGTH, AND SHOW THE NUMBER PROVIDED.
 SEPARATE NORTH, SOUTH EAST AND WEST LENGTHS AND SHOW
 REQUIRED AND PROVIDED TREES FOR EACH.
 WEST BUFFER IS 11 REQUIRED 11 PROVIDED. THIS CAN BE
 CORRECTED
  
 11. SATISFIED. THERE ARE TERMINAL LANDSCAPE ISLANDS
 THAT DO NOT MEET THE 8 FEET LANDSCAPE AREA REQUIRED
 INSIDE THE CURB. REVISE.
  
  
 12. SATISFIED. THERE APPEAR TO BE CONFLICTS IN SEVERAL
 LOCATIONS BETWEEN TREES AND WATER AND SEWER LINES ON
 THE LANDSCAPE PLAN. ADJUST LOCATIONS OF TREES OR
 UTILITY LINES TO RESOLVE CONFLICTS WITH LANDSCAPING.
  
 13. SATISFIED. SHOW COMPLIANCE WITH SECTION 94-445 L.
 PLANT SPECIES. A MINIMUM OF 60 PERCENT OF PLANT
 MATERIAL ADDED SHALL BE FLORIDA NATIVE OR DROUGHT
 TOLERANT SPECIES SELECTED FROM THE CITY LIST OR THE
 LIST OF SPECIES IN THE MOST RECENT EDITION OF SOUTH
 FLORIDA WATER MANAGEMENT DISTRICT WATERWISE SOUTH
 FLORIDA LANDSCAPES. PROVIDE THE ACTUAL PERCENTAGE BASED
 ON THE PLANT LIST.
  
 ADDITIONAL COMMENTS 8/27/20:
 14. SATISFIED REMOVE SKY CLIMBER CULTIVAR AND INDICATE
 SPECIES LIVE OAK.
  
 15. SATISFIED SEPARATE TREES AND SHRUBS ON THE PLANT
 LIST PROVIDED FOR THE NORTH PROPERTY.
  
 CONDITIONS OF APPROVAL
 1. PRIOR TO THE REMOVAL OR RELOCATION OF ANY TREES ON
 THE PROPERTY, A TREE ALTERATION PERMIT SHALL BE
 SUBMITTED, REVIEWED AND APPROVED BY THE DEVELOPMENT
 SERVICES DEPARTMENT, PLANNING DIVISION.
  

Review Stop L LANDSCAPING
Rev No 3 Status F Date 10-22-2020 Cont ID  
Sent By rcaranci Date 10-22-2020 Time 15:51 Rev Time 0.00
Received By rcaranci Date 10-22-2020 Time 15:51 Sent To  
Notes
2020-10-22 15:53:51FROM: RAY CARANCI, SENIOR LANDSCAPE PLANNER
 561-822-1462
 PROJECT: 1600 N AUSTRALIAN Z20060015
 OCTOBER 22, 2020
 I HAVE REVIEWED THE ABOVE REFERENCED PETITION, AND
 PROVIDE THE FOLLOWING COMMENTS:
  
 1. MAKE THE FOLLOWING CORRECTIONS TO THE TREE
 DISPOSITION PLAN SHEET 1 OF 1.
 ? SATISFIED. COLUMN FOR CONDITION MUST BE INCLUDED IN
 THE CHART.
 ? SATISFIED. GIVE THE CONDITION OF EACH TREE.
 ? SATISFIED. INCLUDE CANOPY DIAMETER MEASUREMENT FOR
 TREES IN ORDER TO CALCULATE MITIGATION DUE IF REMOVED.
 ? SATISFIED. CANOPY SQUARE FOOTAGE FOR MITIGATION DUE
 FOR ANY TREES PROPOSED FOR REMOVAL MUST BE IN A
 SEPARATE COLUMN, AND THE TOTAL PROVIDED FOR THE COLUMN.
 ? PARTIALLY SATISFIED. REMOVALS OF PALMS MUST INCLUDE
 THE MITIGATION REQUIRED BY CATEGORY.
 QUEEN PALM 112 AND 5 CHINESE FAN PALMS ARE CATEGORY 4
 MITIGATION REQUIRED 50 SQ FT EACH FOR A TOTAL OF 300 SQ
 FT PLUS 706 FOR JACARANDA. TOTAL IS 1006 SQ FT. UPDATE
 CANOPY REPLACEMENT COLUMN AND TOTAL.
 ? PARTIALLY SATISFIED. INCLUDE A CHART FOR TREE
 MITIGATION PROVIDED BASED ON THE PLANT LIST AND PROVIDE
 THE TOTAL FOR THE SQUARE FOOTAGE.
 INCLUDE ALL TREES ADDED ON LANDSCAPE PLAN AND TOTAL
 CANOPY SQ FT CREDIT.
  
 2. SATISFIED. SECTION 94-448 (D)(3) REQUIRES NATIVE
 TREES IN GOOD CONDITION TO BE PRESERVED ON SITE OR
 RELOCATED. ANSI A 300 (PART 5) STANDARDS SPECIFY
 EXAMPLES OF SUITABILITY RATINGS OF GOOD, MODERATE, OR
 POOR FOR RELOCATION. PROVIDE CONDITION AND RELOCATION
 POTENTIAL FOR THE NATIVE SABAL PALMS.
  
 3. PARTIALLY SATISFIED. CITY POLICY REQUIRES THE USE OF
 FLORIDA NATIVE SPECIES WHEN POSSIBLE. THERE ARE NATIVE
 ALTERNATIVES FOR CARRISSA, PODOCARPUS, AND PITTOSPORUM.
  
 IT WOULD BE BETTER TO HAVE 100% NATIVE IF POSSIBLE.
 PREFERRED TO HAVE SPECIES THAT REQUIRE NO FERTILIZER
 BECAUSE THEY WILL NOT RECEIVE IT.
  
 4. PARTIALLY SATISFIED. CHECK THE FLORIDA FRIENDLY
 DESIGN OPTIONS LIST AND SEE IF MORE POINTS CAN BE ADDED
 THROUGH NATIVE TREES AND SHRUBS. THE ADDITIONAL SHADE
 TREES IN VEHICULAR USE AREAS MUST BE VERIFIED IF
 CLAIMED.
 PLEASE TAKE CREDITS FOR NATIVE TREES AND SHRUBS FIRST.
  
 5. SATISFIED. ADJUST THE CALCULATIONS FOR MINIMUM SHADE
 TREE AND FLOWERING TREE REQUIREMENTS PER SECTION
 94-443(C)(2)B. BASED ON REQUIRED OPEN SPACE OF 14793 SQ
 FT. SHADE TREES-10, FLOWERING TREES -3, SHRUBS -30.
 FLOWERING TREE CATEGORY IS MISSING.
  
 6. PARTIALLY SATISFIED. ADD RELOCATED PALMS TO THE
 PLANT LIST AND COUNT THEM TOWARD THE REQUIRED TREES.
  
 NOT CLEAR IF SABALS LABELED EXISTING ARE RELOCATED. ADD
 THE OTHER EXISTING TREES TO REMAIN TO THE PLANT LIST.
  
 7. SATISFIED. MINIMUM TREE SIZES ARE 12 FEET, AND PALMS
 8 FOOT CLEAR TRUNK. MAKE CORRECTIONS.
  
 8. SATISFIED. PROVIDE A PLAN SHOWING THE PARKING
 LANDSCAPE AREAS COUNTED TOWARD COMPLIANCE WITH SECTION
 94-443(C)(3) AND (4) AND PROVIDE CALCULATIONS.
 CALCULATE SQUARE FOOTAGE REQUIRED PER CODES REFERENCED
 AND SHOW WHERE IT IS PROVIDED WITHIN THE PARKING AREA.
  
 9. SATISFIED. SECTION 94-443(C)(3) REQUIRES THAT A
 MINIMUM OF 75 PERCENT OF ALL TREES THAT ARE REQUIRED TO
 BE PLANTED WITHIN THE INTERIOR OF AN OFF STREET PARKING
 AREA SHALL BE CATEGORY 1 SHADE TREES. SHOW THE
 PERCENTAGE OF CATEGORY 1 TREES PROVIDED FOR THE
 REQUIRED LANDSCAPE AREAS.
  
 10. PARTIALLY SATISFIED. PROVIDE CALCULATIONS FOR
 REQUIRED BUFFER TREES AT ONE FOR EVERY 30 FEET OR
 PORTION THEREOF FOR EACH BUFFER LENGTH, AND SHOW THE
 NUMBER PROVIDED.
 SEPARATE NORTH, SOUTH EAST AND WEST LENGTHS AND SHOW
 REQUIRED AND PROVIDED TREES FOR EACH.
  
 11. SATISFIED. THERE ARE TERMINAL LANDSCAPE ISLANDS
 THAT DO NOT MEET THE 8 FEET LANDSCAPE AREA REQUIRED
 INSIDE THE CURB. REVISE.
  
  
 12. SATISFIED. THERE APPEAR TO BE CONFLICTS IN SEVERAL
 LOCATIONS BETWEEN TREES AND WATER AND SEWER LINES ON
 THE LANDSCAPE PLAN. ADJUST LOCATIONS OF TREES OR
 UTILITY LINES TO RESOLVE CONFLICTS WITH LANDSCAPING.
  
 13. SATISFIED. SHOW COMPLIANCE WITH SECTION 94-445 L.
 PLANT SPECIES. A MINIMUM OF 60 PERCENT OF PLANT
 MATERIAL ADDED SHALL BE FLORIDA NATIVE OR DROUGHT
 TOLERANT SPECIES SELECTED FROM THE CITY LIST OR THE
 LIST OF SPECIES IN THE MOST RECENT EDITION OF SOUTH
 FLORIDA WATER MANAGEMENT DISTRICT WATERWISE SOUTH
 FLORIDA LANDSCAPES. PROVIDE THE ACTUAL PERCENTAGE BASED
 ON THE PLANT LIST.
  
 ADDITIONAL COMMENTS 8/27/20:
 14. SATISFIED REMOVE SKY CLIMBER CULTIVAR AND INDICATE
 SPECIES LIVE OAK.
  
 15. SATISFIED SEPARATE TREES AND SHRUBS ON THE PLANT
 LIST PROVIDED FOR THE NORTH PROPERTY.
  
 CONDITIONS OF APPROVAL
 1. PRIOR TO THE REMOVAL OR RELOCATION OF ANY TREES ON
 THE PROPERTY, A TREE ALTERATION PERMIT SHALL BE
 SUBMITTED, REVIEWED AND APPROVED BY THE DEVELOPMENT
 SERVICES DEPARTMENT, PLANNING DIVISION.
  

Review Stop L LANDSCAPING
Rev No 2 Status F Date 08-28-2020 Cont ID  
Sent By rcaranci Date 08-28-2020 Time 10:07 Rev Time 0.00
Received By rcaranci Date 08-28-2020 Time 10:07 Sent To  
Notes
2020-08-28 10:09:17FROM: RAY CARANCI, SENIOR LANDSCAPE PLANNER
 561-822-1462
 PROJECT: 1600 N AUSTRALIAN Z20060015
 AUGUST 27, 2020
 I HAVE REVIEWED THE ABOVE REFERENCED PETITION, AND
 PROVIDE THE FOLLOWING COMMENTS:
  
 1. MAKE THE FOLLOWING CORRECTIONS TO THE TREE
 DISPOSITION PLAN SHEET 1 OF 1.
 ? SATISFIED. COLUMN FOR CONDITION MUST BE INCLUDED IN
 THE CHART.
 ? SATISFIED. GIVE THE CONDITION OF EACH TREE.
 ? SATISFIED. INCLUDE CANOPY DIAMETER MEASUREMENT FOR
 TREES IN ORDER TO CALCULATE MITIGATION DUE IF REMOVED.
 ? SATISFIED. CANOPY SQUARE FOOTAGE FOR MITIGATION DUE
 FOR ANY TREES PROPOSED FOR REMOVAL MUST BE IN A
 SEPARATE COLUMN, AND THE TOTAL PROVIDED FOR THE COLUMN.
 ? PARTIALLY SATISFIED. REMOVALS OF PALMS MUST INCLUDE
 THE MITIGATION REQUIRED BY CATEGORY.
 QUEEN PALM 112 AND 5 CHINESE FAN PALMS ARE CATEGORY 4
 MITIGATION REQUIRED 50 SQ FT EACH FOR A TOTAL OF 300 SQ
 FT PLUS 706 FOR JACARANDA. TOTAL IS 1006 SQ FT. UPDATE
 CANOPY REPLACEMENT COLUMN AND TOTAL.
 ? PARTIALLY SATISFIED. INCLUDE A CHART FOR TREE
 MITIGATION PROVIDED BASED ON THE PLANT LIST AND PROVIDE
 THE TOTAL FOR THE SQUARE FOOTAGE.
 INCLUDE ALL TREES ADDED ON LANDSCAPE PLAN AND TOTAL
 CANOPY SQ FT CREDIT.
  
 2. SATISFIED. SECTION 94-448 (D)(3) REQUIRES NATIVE
 TREES IN GOOD CONDITION TO BE PRESERVED ON SITE OR
 RELOCATED. ANSI A 300 (PART 5) STANDARDS SPECIFY
 EXAMPLES OF SUITABILITY RATINGS OF GOOD, MODERATE, OR
 POOR FOR RELOCATION. PROVIDE CONDITION AND RELOCATION
 POTENTIAL FOR THE NATIVE SABAL PALMS.
  
 3. PARTIALLY SATISFIED. CITY POLICY REQUIRES THE USE OF
 FLORIDA NATIVE SPECIES WHEN POSSIBLE. THERE ARE NATIVE
 ALTERNATIVES FOR CARRISSA, PODOCARPUS, AND PITTOSPORUM.
  
 IT WOULD BE BETTER TO HAVE 100% NATIVE IF POSSIBLE.
 PREFERRED TO HAVE SPECIES THAT REQUIRE NO FERTILIZER
 BECAUSE THEY WILL NOT RECEIVE IT.
  
 4. PARTIALLY SATISFIED. CHECK THE FLORIDA FRIENDLY
 DESIGN OPTIONS LIST AND SEE IF MORE POINTS CAN BE ADDED
 THROUGH NATIVE TREES AND SHRUBS. THE ADDITIONAL SHADE
 TREES IN VEHICULAR USE AREAS MUST BE VERIFIED IF
 CLAIMED.
 PLEASE TAKE CREDITS FOR NATIVE TREES AND SHRUBS FIRST.
  
 5. SATISFIED. ADJUST THE CALCULATIONS FOR MINIMUM SHADE
 TREE AND FLOWERING TREE REQUIREMENTS PER SECTION
 94-443(C)(2)B. BASED ON REQUIRED OPEN SPACE OF 14793 SQ
 FT. SHADE TREES-10, FLOWERING TREES -3, SHRUBS -30.
 FLOWERING TREE CATEGORY IS MISSING.
  
 6. PARTIALLY SATISFIED. ADD RELOCATED PALMS TO THE
 PLANT LIST AND COUNT THEM TOWARD THE REQUIRED TREES.
  
 NOT CLEAR IF SABALS LABELED EXISTING ARE RELOCATED. ADD
 THE OTHER EXISTING TREES TO REMAIN TO THE PLANT LIST.
  
 7. SATISFIED. MINIMUM TREE SIZES ARE 12 FEET, AND PALMS
 8 FOOT CLEAR TRUNK. MAKE CORRECTIONS.
  
 8. SATISFIED. PROVIDE A PLAN SHOWING THE PARKING
 LANDSCAPE AREAS COUNTED TOWARD COMPLIANCE WITH SECTION
 94-443(C)(3) AND (4) AND PROVIDE CALCULATIONS.
 CALCULATE SQUARE FOOTAGE REQUIRED PER CODES REFERENCED
 AND SHOW WHERE IT IS PROVIDED WITHIN THE PARKING AREA.
  
 9. SATISFIED. SECTION 94-443(C)(3) REQUIRES THAT A
 MINIMUM OF 75 PERCENT OF ALL TREES THAT ARE REQUIRED TO
 BE PLANTED WITHIN THE INTERIOR OF AN OFF STREET PARKING
 AREA SHALL BE CATEGORY 1 SHADE TREES. SHOW THE
 PERCENTAGE OF CATEGORY 1 TREES PROVIDED FOR THE
 REQUIRED LANDSCAPE AREAS.
  
 10. PARTIALLY SATISFIED. PROVIDE CALCULATIONS FOR
 REQUIRED BUFFER TREES AT ONE FOR EVERY 30 FEET OR
 PORTION THEREOF FOR EACH BUFFER LENGTH, AND SHOW THE
 NUMBER PROVIDED.
 SEPARATE NORTH, SOUTH EAST AND WEST LENGTHS AND SHOW
 REQUIRED AND PROVIDED TREES FOR EACH.
  
 11. SATISFIED. THERE ARE TERMINAL LANDSCAPE ISLANDS
 THAT DO NOT MEET THE 8 FEET LANDSCAPE AREA REQUIRED
 INSIDE THE CURB. REVISE.
  
  
 12. SATISFIED. THERE APPEAR TO BE CONFLICTS IN SEVERAL
 LOCATIONS BETWEEN TREES AND WATER AND SEWER LINES ON
 THE LANDSCAPE PLAN. ADJUST LOCATIONS OF TREES OR
 UTILITY LINES TO RESOLVE CONFLICTS WITH LANDSCAPING.
  
 13. SATISFIED. SHOW COMPLIANCE WITH SECTION 94-445 L.
 PLANT SPECIES. A MINIMUM OF 60 PERCENT OF PLANT
 MATERIAL ADDED SHALL BE FLORIDA NATIVE OR DROUGHT
 TOLERANT SPECIES SELECTED FROM THE CITY LIST OR THE
 LIST OF SPECIES IN THE MOST RECENT EDITION OF SOUTH
 FLORIDA WATER MANAGEMENT DISTRICT WATERWISE SOUTH
 FLORIDA LANDSCAPES. PROVIDE THE ACTUAL PERCENTAGE BASED
 ON THE PLANT LIST.
  
 ADDITIONAL COMMENTS 8/27/20:
 14. REMOVE SKY CLIMBER CULTIVAR AND INDICATE SPECIES
 LIVE OAK.
  
 15. SEPARATE TREES AND SHRUBS ON THE PLANT LIST
 PROVIDED FOR THE NORTH PROPERTY.
  
 CONDITIONS OF APPROVAL
 1. PRIOR TO THE REMOVAL OR RELOCATION OF ANY TREES ON
 THE PROPERTY, A TREE ALTERATION PERMIT SHALL BE
 SUBMITTED, REVIEWED AND APPROVED BY THE DEVELOPMENT
 SERVICES DEPARTMENT, PLANNING DIVISION.
  

Review Stop L LANDSCAPING
Rev No 1 Status F Date 07-06-2020 Cont ID  
Sent By rcaranci Date 07-06-2020 Time 16:50 Rev Time 0.00
Received By rcaranci Date 07-06-2020 Time 16:50 Sent To  
Notes
2020-07-06 16:51:13FROM: RAY CARANCI, SENIOR LANDSCAPE PLANNER
 561-822-1462
 PROJECT: 1600 N AUSTRALIAN Z20060015
 JULY 6, 2020
 I HAVE REVIEWED THE ABOVE REFERENCED PETITION, AND
 PROVIDE THE FOLLOWING COMMENTS:
  
 1. MAKE THE FOLLOWING CORRECTIONS TO THE TREE
 DISPOSITION PLAN SHEET 1 OF 1.
 ? COLUMN FOR CONDITION MUST BE INCLUDED IN THE CHART.
 ? GIVE THE CONDITION OF EACH TREE.
 ? INCLUDE CANOPY DIAMETER MEASUREMENT FOR TREES IN
 ORDER TO CALCULATE MITIGATION DUE IF REMOVED.
 ? CANOPY SQUARE FOOTAGE FOR MITIGATION DUE FOR ANY
 TREES PROPOSED FOR REMOVAL MUST BE IN A SEPARATE
 COLUMN, AND THE TOTAL PROVIDED FOR THE COLUMN.
 ? REMOVALS OF PALMS MUST INCLUDE THE MITIGATION
 REQUIRED BY CATEGORY.
 ? INCLUDE A CHART FOR TREE MITIGATION PROVIDED BASED ON
 THE PLANT LIST AND PROVIDE THE TOTAL FOR THE SQUARE
 FOOTAGE.
  
 2. SECTION 94-448 (D)(3) REQUIRES NATIVE TREES IN GOOD
 CONDITION TO BE PRESERVED ON SITE OR RELOCATED. ANSI A
 300 (PART 5) STANDARDS SPECIFY EXAMPLES OF SUITABILITY
 RATINGS OF GOOD, MODERATE, OR POOR FOR RELOCATION.
 PROVIDE CONDITION AND RELOCATION POTENTIAL FOR THE
 NATIVE SABAL PALMS.
  
 3. CITY POLICY REQUIRES THE USE OF FLORIDA NATIVE
 SPECIES WHEN POSSIBLE. THERE ARE NATIVE ALTERNATIVES
 FOR CARRISSA, PODOCARPUS, AND PITTOSPORUM.
  
 4. CHECK THE FLORIDA FRIENDLY DESIGN OPTIONS LIST AND
 SEE IF MORE POINTS CAN BE ADDED THROUGH NATIVE TREES
 AND SHRUBS. THE ADDITIONAL SHADE TREES IN VEHICULAR USE
 AREAS MUST BE VERIFIED IF CLAIMED.
  
 5. ADJUST THE CALCULATIONS FOR MINIMUM SHADE TREE AND
 FLOWERING TREE REQUIREMENTS PER SECTION 94-443(C)(2)B.
 BASED ON REQUIRED OPEN SPACE OF 14793 SQ FT. SHADE
 TREES-10, FLOWERING TREES -3, SHRUBS -30. FLOWERING
 TREE CATEGORY IS MISSING.
  
 6. ADD RELOCATED PALMS TO THE PLANT LIST AND COUNT THEM
 TOWARD THE REQUIRED TREES.
  
 7. MINIMUM TREE SIZES ARE 12 FEET, AND PALMS 8 FOOT
 CLEAR TRUNK. MAKE CORRECTIONS.
  
 8. PROVIDE A PLAN SHOWING THE PARKING LANDSCAPE AREAS
 COUNTED TOWARD COMPLIANCE WITH SECTION 94-443(C)(3) AND
 (4) AND PROVIDE CALCULATIONS. CALCULATE SQUARE FOOTAGE
 REQUIRED PER CODES REFERENCED AND SHOW WHERE IT IS
 PROVIDED WITHIN THE PARKING AREA.
  
 9. SECTION 94-443(C)(3) REQUIRES THAT A MINIMUM OF 75
 PERCENT OF ALL TREES THAT ARE REQUIRED TO BE PLANTED
 WITHIN THE INTERIOR OF AN OFF STREET PARKING AREA SHALL
 BE CATEGORY 1 SHADE TREES. SHOW THE PERCENTAGE OF
 CATEGORY 1 TREES PROVIDED FOR THE REQUIRED LANDSCAPE
 AREAS.
  
 10. PROVIDE CALCULATIONS FOR REQUIRED BUFFER TREES AT
 ONE FOR EVERY 30 FEET OR PORTION THEREOF FOR EACH
 BUFFER LENGTH, AND SHOW THE NUMBER PROVIDED.
  
 11. THERE ARE TERMINAL LANDSCAPE ISLANDS THAT DO NOT
 MEET THE 8 FEET LANDSCAPE AREA REQUIRED INSIDE THE
 CURB. REVISE.
  
  
 12. THERE APPEAR TO BE CONFLICTS IN SEVERAL LOCATIONS
 BETWEEN TREES AND WATER AND SEWER LINES ON THE
 LANDSCAPE PLAN. ADJUST LOCATIONS OF TREES OR UTILITY
 LINES TO RESOLVE CONFLICTS WITH LANDSCAPING.
  
 13. SHOW COMPLIANCE WITH SECTION 94-445 L. PLANT
 SPECIES. A MINIMUM OF 60 PERCENT OF PLANT MATERIAL
 ADDED SHALL BE FLORIDA NATIVE OR DROUGHT TOLERANT
 SPECIES SELECTED FROM THE CITY LIST OR THE LIST OF
 SPECIES IN THE MOST RECENT EDITION OF SOUTH FLORIDA
 WATER MANAGEMENT DISTRICT WATERWISE SOUTH FLORIDA
 LANDSCAPES. PROVIDE THE ACTUAL PERCENTAGE BASED ON THE
 PLANT LIST.
  
 CONDITIONS OF APPROVAL
 1. PRIOR TO THE REMOVAL OR RELOCATION OF ANY TREES ON
 THE PROPERTY, A TREE ALTERATION PERMIT SHALL BE
 SUBMITTED, REVIEWED AND APPROVED BY THE DEVELOPMENT
 SERVICES DEPARTMENT, PLANNING DIVISION.
  

Review Stop PARK PARKING
Rev No 1 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time  
Received By   Date   Time   Sent To  
Notes
***NONE***

Review Stop POLICE POLICE
Rev No 1 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time  
Received By   Date   Time   Sent To  
Notes
***NONE***

Review Stop PW PUBLIC WORKS
Rev No 2 Status P Date 08-27-2020 Cont ID  
Sent By   Date 08-27-2020 Time   Rev Time 0.00
Received By   Date 08-27-2020 Time   Sent To  
Notes
2020-08-27 14:35:21NO FURTHER COMMNETS.
  
 MATT HEJAZI
 DEPT. OF PUBLIC WORKS
 [email protected]

Review Stop PW PUBLIC WORKS
Rev No 1 Status F Date 07-02-2020 Cont ID  
Sent By   Date 07-02-2020 Time   Rev Time  
Received By   Date 07-02-2020 Time   Sent To  
Notes
2020-07-02 14:52:50PLEASE PROVIDE AUTO TURN FOR THE SANITATION SERVICE,
 FRONT LOADER TRUCK WITH THE FOLLOWING SPECS:
 - TRUCK LENGTH: 35 FT
 - TRUCK WIDTH: 11 FT
 - TURNING RADIUS:
 - SAE TURNING RADIUS: 32.5 FT
 - CURB-TO-CURB DIAMETER: 74 FT
 - WALL-TO-WALL DIAMETER: 86.3 FT
  
 FOR A FREESTANDING SITE DUMPSTER ENCLOSURE, THE
 ENCLOSURE SHALL COMPLY WITH THE LATEST REVISION OF CITY
 OF WEST PALM BEACH GENERAL CONSTRUCTION-GARBAGE
 ENCLOSURE STANDARD, CG-7.
  
 MATT HEJAZI
 PUBLIC WORKS
 [email protected]
 561-822-2945

Review Stop STORM STORMWATER
Rev No 3 Status P Date 11-02-2020 Cont ID  
Sent By tward Date 11-02-2020 Time 22:49 Rev Time 0.00
Received By tward Date 11-02-2020 Time 22:52 Sent To  
Notes
2020-11-02 22:52:04THE FOLLOWING COMMENTS ARE FROM THE REVIEW OF THE
 10/14/2020 SUBMITTAL PACKAGE. THEY CAN BE ADDRESSED
 DURING ENGINEERING PERMIT SUBMITTAL.
  
 1. ADD VERTICAL DATUM REFERENCE AND CONVERSION EQUATION
 TO NGVD1929 FOR THE TBM'S ON SHEET C-04.
  
 2. CHANGE SPELLING OF CULVER CANAL TO CARVER CANAL ON
 SHEET C-04.
  
 3. SHEET C-14 SHOWS PROPOSED MINIMUM PERIMETER
 ELEVATION OF 15.83 FEET NAVD1988. SECTION D-D ON THE
 SAME SHEET SHOWS BERM TO BE BETWEEN 16.85 AND 17.51
 FEET NAVD AND GRADE AT PROPERTY LINE BETWEEN 17.1 AND
 17.5 FEET NAVD. WOULD A SWALE INSTEAD OF A BERM BE MORE
 APPROPRIATE ALONG THE EAST PROPERTY LINE?
  
 4. THE YARD DRAIN APPEAR TO BE CONNECTED TO THE ONSITE
 DRAINAGE SYSTEM. WHY DO THEY NEED TO BE PERFORATED
 BASINS AS INDICATED IN THE YARD DRAIN DETAIL ON SHEET
 C-14?
  
 TRACY WARD, P.E.
 SENIOR STORMWATER ENGINEER
 ENGINEERING SERVICES DEPARTMENT
 561-494-1120 (O)
 561-351-0510 (M)
 [email protected]
  

Review Stop STORM STORMWATER
Rev No 2 Status F Date 09-18-2020 Cont ID  
Sent By tward Date 09-18-2020 Time 14:24 Rev Time 0.00
Received By tward Date 09-18-2020 Time 15:04 Sent To  
Notes
2020-09-18 15:02:00THE FOLLOWING COMMENTS ARE FROM THE REVIEW OF THE
 8/19/2020 SUBMITTAL PACKAGE.
  
 1. THE EXFILTRATION TRENCH DETAIL SHOWS THE TOP OF
 TRENCH ELEVATION AS 13.50' NAVD. THE CONTROL STRUCTURE
 DETAIL SHOWS THE WEIR ELEVATION AT 12.43' NAVD. THE
 WEIR ELEVATION SHOULD BE SUCH TO COMPLETELY SURCHARGE
 THE EXFILTRATION TRENCH.
  
 2. THE CONTROL STRUCTURE DETAIL SHOWS A 2" WIDE X 26"
 LONG BLEEDER AS PART OF THE WEIR STRUCTURE. NOTE THE
 CITY DOES NOT ALLOW BLEEDERS WITH EXFILTRATION TRENCHES
 UNLESS THERE IS A CONTROL STRUCTURE UPSTREAM OF THE
 BLEEDER THAT WILL SURCHARGE THE EXFILTRATION TRENCH.
  
 3. A NOTE ON SHEET C-07 CALLS OUT A 3" WEIR AT
 ELEVATION 12.43 FEET. SHOULD THIS BE 3' INSTEAD OF 3"?
  
 4. LIST THE VERTICAL DATUM AND CONVERSION EQUATION TO
 NGVD1929 ON EVERY SHEET WITH ELEVATION INFORMATION.
  
 5. SPECIFY RCP WHEN PROPOSED IN THE R/W.
  
 6. FLOATING TURBIDITY BARRIERS MAY BE REQUIRED AT THE
 END(S) OF THE 60" RCP.
  
 7. SHOW STOP BAR AND STOP SIGN AT DRIVEWAY.
  
 8. SHOW CROSSWALKS CROSSING DRIVE LANE AT THE HANDICAP
 ACCESS AISLES.
  
 TRACY WARD, P.E.
 SENIOR STORMWATER ENGINEER
 ENGINEERING SERVICES DEPARTMENT
 561-494-1120 (O)
 561-351-0510 (M)
 [email protected]
  

Review Stop STORM STORMWATER
Rev No 1 Status F Date 07-09-2020 Cont ID  
Sent By tward Date 07-09-2020 Time 10:13 Rev Time 0.00
Received By tward Date 07-09-2020 Time 10:16 Sent To  
Notes
2020-07-09 10:14:27THIS IS A CONCEPTUAL LEVEL REVIEW. CONSTRUCTION LEVEL
 DETAILS, DESIGN CALCULATIONS AND THE POLLUTION
 PREVENTION PLAN WILL BE REVIEWED AS PART OF THE
 ENGINEERING DEVELOPMENT APPROVAL AND BUILDING PERMIT
 APPLICATION PROCESSES.
  
 THE FOLLOWING COMMENTS MUST BE ADDRESSED PRIOR TO SITE
 PLAN APPROVAL:
  
 1. PROVIDE CONDITION ASSESSMENT OF EXISTING 60" RCP
 THAT THE DRAINAGE SYSTEM WILL CONNECT TO.
  
 2. THE CITY'S DRIVEWAY DETAIL IS FOR A CONCRETE APRON
 WITHIN THE RIGHT OF WAY.
  
 3. AUSTRALIAN AVENUE AND PALM BEACH LAKES BLVD. ARE
 MAINTAINED BY PALM BEACH COUNTY. PERMITS MAY BE
 REQUIRED FROM THE COUNTY FOR WORK WITHIN THE ROAD
 RIGHT-OF-WAYS.
  
 4. CONSIDER REDUCING THE PARKING STALL LENGTH BY
 INCORPORATING A 2' LANDSCAPED OVERHANG.
  
 5. LABEL THE PAVER AREA ON THE WEST SIDE OF THE
 BUILDING ON THE ENGINEERING PLANS.
  
 6. THE FIRE HYDRANT IS SHOWN CONNECTED TO THE BFO LINE
 INSTEAD OF THE WATER MAIN ON AUSTRALIAN AVE.
  
 7. SHOW THE PROPOSED FIRE HYDRANT AND UTILITY EASEMENT
 ON THE LANDSCAPE PLAN.
  
 8. WILL A PERIMETER BERM BE NEEDED FOR SECTIONS A-A AND
 E-E?
  
 9. DRAINAGE SYSTEM TO MEET SFWMD ERP CRITERIA.
  
 THE FOLLOWING COMMENTS MUST BE ADDRESSED PRIOR TO
 ISSUANCE OF CONSTRUCTION AUTHORIZATION INCLUDING
 BUILDING PERMITS AND ENGINEERING DEVELOPMENT APPROVAL.
  
 1. AN ENGINEERING DEVELOPMENT APPROVAL APPLICATION MAY
 BE REQUIRED FROM THE ENGINEERING SERVICES DEPARTMENT.
  
 2. EROSION CONTROL PLAN AND DETAILS TO BE SUBMITTED
 WITH THE ENGINEERING PERMIT APPLICATION.
  
 3. PROVIDE A COPY OF THE SFWMD ERP AND DRAINAGE
 CALCULATIONS PRIOR TO STARTING CONSTRUCTION.
  
 TRACY WARD, PE
 SENIOR STORMWATER ENGINEER
 ENGINEERING SERVICES DEPARTMENT
 561-494-1120 (O)
 561-351-0510 (M)
 [email protected]
  

Review Stop SURVEY SURVEYING
Rev No 2 Status P Date 09-11-2020 Cont ID  
Sent By vnoel Date 09-11-2020 Time 13:48 Rev Time 0.00
Received By vnoel Date   Time   Sent To  
Notes
2020-09-11 13:49:46LAW DEPT. WORKING ON REVISED SHARED PARKING AGREEMENT.

Review Stop SURVEY SURVEYING
Rev No 1 Status F Date 07-07-2020 Cont ID  
Sent By vnoel Date 07-07-2020 Time 09:14 Rev Time  
Received By vnoel Date   Time   Sent To  
Notes
2020-07-07 09:48:041. SURVEY NEEDS TO BE SIGNED AND SEALED.
 2. PARKING AGREEMENT IN ORB 26131/545 NEEDS TO BE
 SHOWN. WILL NEED TO BE MODIFIED.
 3. ADD CONVERSION TO NGVD ON SURVEY AND ENG. PLANS.
 4. SURVEY ALSO INCLUDES URBAN LEAGUE PROPERTY?
 5. EXISTING WATER AND SEWER SERVICES WILL NEED TO BE
 VERIFIED.

Review Stop TRAFFIC TRAFFIC ENGINEERING
Rev No 3 Status P Date 11-06-2020 Cont ID  
Sent By   Date 11-06-2020 Time   Rev Time 0.00
Received By   Date   Time   Sent To  
Notes
2020-11-06 14:47:33PASSED WITH THE FOLLOWING CONDITIONS:
  
 1) PROVIDE COUNTY TPS LETTER ONCE OBTAINED
 2) REVIEW BUDGET AND PROVIDE FEEDBACK AT NEXT/FINALL
 SUBMISSION FOR POSSIBILITY OF EXPANDING THE SIDEWALK
 ALONG AUSTRALIAN AVE. TO 10'
  
 VALERIO ORICCHIO
 CITY TRANSPORTATION ENGINEER
 561-494-1092
 [email protected]

Review Stop TRAFFIC TRAFFIC ENGINEERING
Rev No 2 Status F Date 09-04-2020 Cont ID  
Sent By   Date 09-04-2020 Time   Rev Time 0.00
Received By   Date 08-19-2020 Time   Sent To  
Notes
2020-09-04 15:04:02TRAFFIC COMMENTS
 1) PROVIDE COUNTY TPS LETTER ONCE THE TRAFFIC STUDY HAS
 BEEN APPROVED
 2) REVIEW POSSIBILITY OF WIDER SIDEWALK ALONG
 AUSTRALIAN AVENUE (FROM EXISTING5 FEET TO 8 FEET WIDE)
  
 VALERIO ORICCHIO
 CITY TRANSPORTATION ENGINEER
 561-494-1092
 [email protected]
  

Review Stop TRAFFIC TRAFFIC ENGINEERING
Rev No 1 Status F Date 07-09-2020 Cont ID  
Sent By   Date 07-09-2020 Time   Rev Time  
Received By   Date   Time   Sent To  
Notes
2020-07-09 13:04:40 
 1. PROVIDE COUNTY TPS LETTER
 2. IDENTIFY THE LOADING ZONE
 3. PROVIDE AUTOTURN ANALYSIS FOR VEHICLES PARKING IN
 AND OUT OF THE LAST STALLS ON THE WEST SIDE LOTS
 4. PROVIDE WIDER SIDEWALK ALONG AUSTRALIAN AVENUE
 (MINIMUM 8?)
 5. IF THE NE HANDICAP PARKING STALL IS INTENDED FOR THE
 EXISTING URBAN LEAGUE BUILDING, THAT SITE NEEDS TO BE
 INCLUDED IN THE PLANS
  
  
 VALERIO ORICCHIO
 CITY TRANSPORTATION ENGINEER
 561-494-1092
 [email protected]
  

Review Stop Z ZONING
Rev No 3 Status P Date 11-10-2020 Cont ID  
Sent By   Date 11-10-2020 Time   Rev Time 0.00
Received By   Date 11-10-2020 Time   Sent To  
Notes
2020-11-10 16:21:21HCD INFORMAL SITE PLAN REVIEW 1600 N AUSTRALIAN AVENUE
 - PROJECT #Z20060015
 PROCESS COMMENTS:
  
 -PLEASE NOTE THAT YOU WILL BE ACCESSED A RESUBMITTAL
 FEE OF 20% OF THE ORIGINAL APPLICATION FEE.
  
 *******************************************************
 ***********
  
 - PROVIDE INFORMATION ON SHARED PARKING AGREEMENT.
 INFORMATION TO BE PROVIDED PRIOR TO CO.
  
  
 ALANA WOOTEN
 PLANNER
 PLANNING DIVISION
 561-822-1449
 [email protected]
  

Review Stop Z ZONING
Rev No 2 Status F Date 09-17-2020 Cont ID  
Sent By   Date 09-17-2020 Time   Rev Time 0.00
Received By   Date 09-17-2020 Time   Sent To  
Notes
2020-09-21 09:47:11HCD INFORMAL SITE PLAN REVIEW ? 1600 N AUSTRALIAN
 AVENUE - PROJECT #Z20060015
  
 PROCESS COMMENTS:
  
 -PLEASE PROVIDE RESPONSES TO ALL REVIEW COMMENTS IN
 WRITTEN FORMAT.
 -PLEASE NOTE THAT YOU WILL BE ACCESSED A RESUBMITTAL
 FEE ON SUBSEQUENT SUBMITTALS. SUCH FEE WILL BE 20% OF
 THE ORIGINAL APPLICATION FEE.
  
 *******************************************************
 ***********
  
 - PROVIDE TRAFFIC CONCURRENCY LETTER. SATISFIED
  
 - PROVIDE UTILITY LETTERS. SATISFIED
  
 - PROVIDE THE STANDARDS FOR CODE COMPLIANCE. SATISFIED
  
 - PROVIDE SIGNED AND SEALED PLANS (DIGITAL).
 ACKNOWLEDGED FOR NEXT SUBMITTAL
  
 - CONSIDER MORE BICYCLE PARKING FOR THE VISITORS/GUESTS
 OF THE VICKERS HOUSE. SATISFIED
  
 - CONSIDER PROVIDING A SHOWER FACILITY. SATISFIED
  
 - ADD THE BICYCLE PARKING TO THE INFORMATION TABLE.
 SATISFIED
  
 - CONSIDER RE-DESIGNING THE PARKING AREA AROUND THE
 ENTRANCE WITH THE DEAD-END PARKING ON BOTH SIDES. A
 POSSIBLE SOLUTION MAYBE TO DESIGNATE A PARKING SPACE
 FOR TURN AROUND. SATISFIED
  
 - PROVIDE INFORMATION ON SHARED PARKING AGREEMENT. NOT
 SATISFIED
  
 - PROVIDE A LOADING SPACE BY CODE. (10? X 25?).
 SATISFIED
  
 - SEE THE CITY?S TYPICAL DUMPSTER ENCLOSURE DETAIL.
 SATISFIED.
  
 - SIGNAGE WILL REQUIRE A SEPARATE PERMIT. ACKNOWLEDGED.
  
 ALANA WOOTEN
 PLANNER
 PLANNING DIVISION
 561-822-1449
 [email protected]
  

Review Stop Z ZONING
Rev No 1 Status F Date 07-07-2020 Cont ID  
Sent By   Date 07-07-2020 Time   Rev Time  
Received By   Date 07-07-2020 Time   Sent To  
Notes
2020-07-07 13:33:55PPRC ZONING REVIEW - HCD COMMUNITY RESOURCE CENTER -
 1600 N. AUSTRALIAN AVENUE
  
 - PROVIDE TRAFFIC CONCURRENCY LETTER
  
 - PROVIDE UTILITY LETTERS.
  
 - PROVIDE THE STANDARDS FOR CODE COMPLIANCE.
  
 - PROVIDE SIGNED AND SEALED PLANS.
  
 - CONSIDER MORE BICYCLE PARKING FOR THE VISITORS/GUESTS
 OF THE VICKERS HOUSE.
  
 - CONSIDER PROVIDING A SHOWER FACILITY.
  
 - ADD THE BICYCLE PARKING TO THE INFORMATION TABLE.
  
 - CONSIDER RE-DESIGNING THE PARKING AREA AROUND THE
 ENTRANCE WITH THE DEAD-END PARKING ON BOTH SIDES. A
 POSSIBLE SOLUTION MAYBE TO DESIGNATE A PARKING SPACE
 FOR TURN AROUND.
  
 - PROVIDE INFORMATION ON SHARED PARKING AGREEMENT.
  
 - PROVIDE A LOADING SPACE BY CODE. (10? X 25?).
  
 - SEE THE CITY?S TYPICAL DUMPSTER ENCLOSURE DETAIL.
  
 - SIGNAGE WILL REQUIRE A SEPARATE PERMIT.
  
 ALANA WOOTEN
 PLANNER
 PLANNING DIVISION
 561-822-1449
 [email protected]
  

  Print