Plan Review Details - Project Z20060015
| Plan Review Stops For Project Z20060015 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
11-12-2020 |
|
|
Cont ID |
|
| Sent By |
rbrown |
Date |
11-12-2020 |
Time |
16:23 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
11-12-2020 |
Time |
16:23 |
Sent To |
|
|
| Notes |
| 2020-11-12 16:26:21 | DEVELOPMENT SERVICES DEPARTMENT, BUILDING DIVISION, | | | COMMENTS: | | | | | | THIS REVIEW IS A CURSORY REVIEW AS IT RELATES TO THE | | | SITE. IT IS NOT A REVIEW FOR FULL COMPLIANCE WITH | | | FLORIDA BUILDING CODE. | | | | | | REVIEW PASSED. THE FOLLOWING COMMENTS ARE TO BE | | | ADDRESSED FOR THE BUILDING PERMIT APPLICATION: | | | | | | 1. BUILDING SIZE. WHEN SUBMITTED FOR BUILDING PERMIT, | | | THE PLANS SHALL SHOW THAT THE TYPE OF CONSTRUCTION FOR | | | THE BUILDINGS WILL BE IN ACCORDANCE WITH THE HEIGHT, | | | AREA AND OCCUPANCY LIMITATIONS IN CHAPTER 5 OF THE | | | FLORIDA BUILDING CODE. | | | | | | 2. SEPARATE PERMITS REQUIRED. ALL APPLICABLE PERMITS | | | AND SUB-PERMITS MUST BE OBTAINED BEFORE COMMENCING THE | | | WORK. SEPARATE PERMITS, PLANS AND FEES, ARE REQUIRED | | | FOR SIGNS, GAS SYSTEMS, GENERATORS, FIRE ALARM SYSTEMS, | | | FIRE SPRINKLER AND OTHER FIRE SUPPRESSION SYSTEMS, | | | GREASE INTERCEPTORS, SITE LIGHTING, SITE LANDSCAPE, | | | SITE IRRIGATION, ETC. | | | | | | 3. CONTRACTOR VEHICLE PARKING. PROPERTY OWNER AND | | | CONTRACTOR SHALL MAKE ARRANGEMENTS FOR PARKING OF | | | CONTRACTOR VEHICLES TO MINIMIZE THE IMPACT ON ALL | | | NEIGHBORING PROPERTIES. | | | | | | 4. PROTECTION OF NEIGHBORING PROPERTY. PROPERTY OWNER | | | AND CONTRACTOR SHALL PROTECT ALL NEIGHBORING PROPERTY, | | | INCLUDING VEHICLES, FROM DAMAGE OR DIRT CAUSED BY THE | | | CONSTRUCTION, AND SHALL NOTIFY THE OCCUPANTS OF | | | NEIGHBORING PROPERTIES ABOUT ALL STAGES OF CONSTRUCTION | | | THAT MAY AFFECT THE USE OF THEIR PROPERTY. | | | | | | 5. BUILDING ADDRESS. EACH SEPARATE BUILDING, AND UNIT | | | WITH AN INDEPENDENT ENTRANCE FROM THE STREET, SHALL | | | HAVE A SEPARATE ADDRESS. FOR STREET ADDRESSING, CONTACT | | | CAROLINE PUELL, ADDRESSING COORDINATOR, AT (561) 805 | | | 6659, OR BY EMAIL: [email protected] | | | | | | | | | ROBERT BROWN | | | BUILDING OFFICIAL | | | TEL: 561 805 6652 | | | EMAIL: [email protected] | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
11-12-2020 |
|
|
Cont ID |
|
| Sent By |
rbrown |
Date |
09-18-2020 |
Time |
19:55 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
09-18-2020 |
Time |
19:55 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
07-08-2020 |
|
|
Cont ID |
|
| Sent By |
rbrown |
Date |
07-08-2020 |
Time |
20:04 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
07-08-2020 |
Time |
20:04 |
Sent To |
|
|
| Notes |
| 2020-07-08 20:12:27 | DEVELOPMENT SERVICES DEPARTMENT, BUILDING DIVISION, | | | COMMENTS: | | | | | | 1. THIS REVIEW IS A CURSORY REVIEW AS IT RELATES TO THE | | | SITE. IT IS NOT A REVIEW FOR FULL COMPLIANCE WITH | | | FLORIDA BUILDING CODE. THE FOLLOWING COMMENTS ARE TO BE | | | ADDRESSED FOR THE BUILDING PERMIT APPLICATION. | | | | | | 2. LOCATION OF ACCESSIBLE PARKING SPACES. TWO | | | ACCESSIBLE PARKING SPACES ARE REQUIRED. SITE PLAN SHEET | | | A1.1 SHOWS ONE OF THE PROPOSED ACCESSIBLE PARKING | | | SPACES LOCATED AROUND 200 FEET FROM THE BUILDING | | | ENTRANCE. THE ACCESSIBLE PARKING SPACE SHOULD BE | | | LOCATED SO THAT IT IS THE CLOSEST PARKING SPACE TO THE | | | BUILDING ENTRANCE. PER SECTION 208.3 OF FLORIDA | | | ACCESSIBILITY CODE, ACCESSIBLE PARKING SPACES ARE TO BE | | | LOCATED ON THE SHORTEST POSSIBLE ROUTE OF TRAVEL FROM | | | ADJACENT PARKING TO AN ACCESSIBLE ENTRANCE. THE DESIGN | | | OF ACCESSIBLE PARKING SPACES SHALL COMPLY WITH SECTION | | | 502 OF FLORIDA ACCESSIBILITY CODE | | | | | | 3. BUILDING SIZE. WHEN SUBMITTED FOR BUILDING PERMIT, | | | THE PLANS SHALL SHOW THAT THE TYPE OF CONSTRUCTION FOR | | | THE BUILDINGS WILL BE IN ACCORDANCE WITH THE HEIGHT, | | | AREA AND OCCUPANCY LIMITATIONS IN CHAPTER 5 OF THE | | | FLORIDA BUILDING CODE. | | | | | | 4. SEPARATE PERMITS REQUIRED. ALL APPLICABLE PERMITS | | | AND SUB-PERMITS MUST BE OBTAINED BEFORE COMMENCING THE | | | WORK. SEPARATE PERMITS, PLANS AND FEES, ARE REQUIRED | | | FOR SIGNS, GAS SYSTEMS, GENERATORS, FIRE ALARM SYSTEMS, | | | FIRE SPRINKLER AND OTHER FIRE SUPPRESSION SYSTEMS, | | | GREASE INTERCEPTORS, SITE LIGHTING, SITE LANDSCAPE, | | | SITE IRRIGATION, ETC. | | | | | | 5. CONTRACTOR VEHICLE PARKING. PROPERTY OWNER AND | | | CONTRACTOR SHALL MAKE ARRANGEMENTS FOR PARKING OF | | | CONTRACTOR VEHICLES TO MINIMIZE THE IMPACT ON ALL | | | NEIGHBORING PROPERTIES. | | | | | | 6. PROTECTION OF NEIGHBORING PROPERTY. PROPERTY OWNER | | | AND CONTRACTOR SHALL PROTECT ALL NEIGHBORING PROPERTY, | | | INCLUDING VEHICLES, FROM DAMAGE OR DIRT CAUSED BY THE | | | CONSTRUCTION, AND SHALL NOTIFY THE OCCUPANTS OF | | | NEIGHBORING PROPERTIES ABOUT ALL STAGES OF CONSTRUCTION | | | THAT MAY AFFECT THE USE OF THEIR PROPERTY. | | | | | | 7. BUILDING ADDRESS. EACH SEPARATE BUILDING, AND UNIT | | | WITH AN INDEPENDENT ENTRANCE FROM THE STREET, SHALL | | | HAVE A SEPARATE ADDRESS. FOR STREET ADDRESSING, CONTACT | | | CAROLINE PUELL, ADDRESSING COORDINATOR, AT (561) 805 | | | 6659, OR BY EMAIL: [email protected] | | | | | | | | | ROBERT BROWN | | | BUILDING OFFICIAL | | | TEL: 561 805 6652 | | | EMAIL: [email protected] | | | | | | |
|
|
| Review Stop |
ENG - PPRC |
ENGINEERING - PPRC |
| Rev No |
3 |
Status |
P |
Date |
10-19-2020 |
|
|
Cont ID |
|
| Sent By |
rrossano |
Date |
10-19-2020 |
Time |
|
Rev Time |
0.00 |
| Received By |
rrossano |
Date |
10-19-2020 |
Time |
|
Sent To |
|
|
| Notes |
| 2020-10-19 13:55:21 | PASSED WITH PROVISOS: | | | | | | ZONING APPROVAL IS NECESSARY PRIOR TO FORMAL | | | ENGINEERING SUBMITTAL. | | | | | | THE FOLLOWING COMMENTS ARE FROM MARK HURLEY, FIELD | | | CUSTOMER SERVICE SUPERVISOR, WPB PUBLIC UTILITIES, | | | PLEASE CONTACT 561-494-2262 OR [email protected]: | | | | | | SHEET C-11 | | | -REPLACE STANDARD DETAIL WS-8 WITH WS-1. (METER BOXES | | | NOT IN SIDEWALKS) | | | -REMOVE WS-12. (NOT NEEDED AS INSTALLING RP?S AND WS-6 | | | ALREADY INCLUDED) | | | -#2 ON ENLARGED PLAN SAYS USE EXISTING BOX FOR 1.5 IN. | | | METER, BUT THE BOX IS TOO SMALL FOR THAT. WOULD HAVE TO | | | REPLACE WITH BIGGER FLARED WALL METER BOX THAT HAS 17 | | | IN. X 30 IN. LID. (NEED TO ALSO UPDATE SIMILAR NOTES ON | | | SHEET C-6) | | | | | | SHEET C-6 | | | -IS THE MILLING AND RESURFACING ON AUSTRALIAN AV. JUST | | | FOR THE FIRE HYDRANT INSTALLATION ON THE WATER MAIN? IF | | | SO, THEN IT MAY NOT BE NEEDED IF THE WATER MAIN IS | | | FOUND TO BE IN THE MIDDLE OF THE GRASS PARKWAY INSTEAD | | | OF ON EDGE OF ROAD. COULD ADD NOTE TO VERIFY IF IT | | | REQUIRED AFTER FIRE HYDRANT INSTALLATION IS COMPLETE. | | | -PLAN DOES NOT SHOW NUMERICAL PROPERTY ADDRESS AND DOES | | | NOT HAVE A RECENT REVISION DATE. PLEASE ADD TO FORMAL | | | ENGINEERING SUBMITTAL. | | | -THE MIDDLE WATER SERVICE OF THREE IS NOT DRAWN. PLEASE | | | ADD TO FORMAL ENGINEERING SUBMITTAL. | | | | | | ADDITIONAL COMMENTS FROM OCT 7 2020 ZOOM MEETING WITH | | | LAURA LE, SUZANNE BERGLUND, TRACY WARD, DANA GILLETTE, | | | STEPHON HARRIS TO BE ADRESSED WITH NEXT SUBMITTAL: | | | | | | SEWER | | | 1. THE CLEAN OUT SHOULD BE MOVED TO BEHIND THE SIDEWALK | | | WITH A CONCRETE COLLAR. | | | 2. THE SEWER LATERAL SHOULD BE LINED DUE TO A CRACK IN | | | THE PIPE NEAR THE MANHOLE. SUZANNE WILL PROVIDE THE | | | CITY STANDARD SPEC. | | | 3. ADD A NOTE THAT THE CONTRACTOR IS TO COORDINATE WITH | | | THE CITY UTILITY DEPT FOR WORK ON THE CITY?S WATER AND | | | SEWER LINES. | | | 4. ADD A NOTE THAT THE CONTRACTOR IS TO OBTAIN A POST | | | CONSTRUCTION CCTV OF THE SEWER LATERAL. | | | 5. THERE IS AN UNKNOWN UTILITY LINE. ADD A NOTE THAT | | | THE CONTRACTOR IS TO LOCATE ALL PIPES/UTILITIES THAT | | | ARE DISCOVERED/ CROSSED AND PROVIDE THEIR LOCATION ON | | | THE AS BUILTS. | | | 6. ADD THE RIGHT OF WAY LINE TO THE PLANS. | | | 7. ADD A UTILITY EASEMENT AROUND THE NEW CLEAN OUT. | | | 8. LAURA NOTED THAT THERE IS A FORCE MAIN ON THE SOUTH | | | SIDE OF 15TH ST, BUT THAT IT IS OUTSIDE OF THE PROPOSED | | | WORK AREA. | | | | | | WATER SERVICE | | | 9. DANA NOTED THAT SHE?S BEEN COORDINATING WITH MARK | | | HURLEY ABOUT THE WATER SERVICE CONFIGURATION. LAURA | | | NOTED THAT IF THE 4? LINE, OR ANY OF THE THREE | | | SERVICES, HAS AN ISSUE THEN ALL THREE SERVICES WILL BE | | | IMPACTED. DANA NOTED THAT SINCE TWO ARE IRRIGATION | | | LINES, THEY CAN BE TAKEN OUT OF SERVICE WITHOUT SERIOUS | | | IMPACT. | | | 10. ADD THE FOLLOWING TO THE WATER SERVICE SKETCH: | | | MATERIAL OF THE 4? PIPE (CAST IRON), LOCATION OF THE | | | CAP, LOCATION OF THE 1? COPPER, NOTE TO CAP THE 1? | | | COPPER AT THE MAIN, NOTE THAT THE AS-BUILTS ARE TO | | | INCLUDE DETAILS OF THE SERVICE SKETCH AND ANY CAPPED | | | LINES. | | | 11. ADD TO THE TABLE HOW WE DID THE MATH TO DETERMINE | | | THE FLOW FOR THE WATER AND SEWER. | | | | | | | | | FEEL FREE TO CONTACT US IF YOU HAVE ANY QUESTIONS OR | | | CONCERNS, THANKS. | | | RICK ROSSANO, PROJECT COORDINATOR, ENGINEERING SERVICES | | | DEPARTMENT | | | DIRECT: (561) 494-1098 [email protected] | | | | | | |
|
|
| Review Stop |
ENG - PPRC |
ENGINEERING - PPRC |
| Rev No |
2 |
Status |
F |
Date |
08-27-2020 |
|
|
Cont ID |
|
| Sent By |
rrossano |
Date |
08-27-2020 |
Time |
|
Rev Time |
0.00 |
| Received By |
rrossano |
Date |
08-27-2020 |
Time |
|
Sent To |
|
|
| Notes |
| 2020-08-27 12:47:06 | THE FOLLOWING COMMENTS ARE FROM MARK HURLEY, FIELD | | | CUSTOMER SERVICE SUPERVISOR, WPB PUBLIC UTILITIES, | | | PLEASE CONTACT 561-494-2262 OR [email protected]: | | | | | | FOLLOWUP COMMENTS CONCERNING SHEET C-06: | | | WATER SERVICES AND METERS APPEAR TO STILL NOT BE | | | ACCURATE RELATED TO EXISTING CONDITIONS ON SITE. THE | | | EASTERN EXISTING METER HAS NO DAMAGE (I THINK THE BOX | | | WAS REPLACED RECENTLY) AND IS THE ? IN. METER | | | HISTORICALLY USED FOR DOMESTIC WATER AT THE PROPERTY. | | | THAT METER COULD NOT BE UPGRADED TO 2 IN. AS THE | | | SERVICE LINE IS SMALL. THE WESTERN EXISTING METER AT | | | SOUTH END OF PROPERTY IS THE PARKS DEPARTMENT 1.5 IN. | | | IRRIGATION METER THAT MR. KRISCHE ADVISED IN JULY 2020 | | | NEEDED TO REMAIN IN TACT FOR FUTURE USE ? ONLY LABEL | | | ?PARK DEPARTMENT TO REMOVE? IF PARKS REPRESENTATIVE | | | ADVISED THAT WAS THEIR INTENTION. TO INCREASE THE ? IN. | | | DOMESTIC METER TO 1.5 IN., THE SMALL SERVICE LINE WOULD | | | HAVE TO BE REPLACED WITH A 2 IN. SERVICE LINE PER WATER | | | SERVICE STANDARD DETAILS AND APPROVED MATERIAL LIST. | | | -THE EXISTING PVB BACKFLOW ASSEMBLY FOR THE EXISTING | | | PARKS IRRIGATION METER IS THEIR PROPERTY. APPROVAL | | | WOULD NEED TO BE OBTAINED PARKS REPRESENTATIVES TO | | | REMOVE IT. THE ASSEMBLY COULD NOT BE RELOCATED AND | | | REUSED AS A CONTAINMENT BACKFLOW ASSEMBLY IN OUR WATER | | | SERVICE AREA. | | | | | | FEEL FREE TO CONTACT US IF YOU HAVE ANY QUESTIONS OR | | | CONCERNS, THANKS. | | | RICK ROSSANO, PROJECT COORDINATOR, ENGINEERING SERVICES | | | DEPARTMENT | | | DIRECT: (561) 494-1098 [email protected] | | | |
|
|
| Review Stop |
ENG - PPRC |
ENGINEERING - PPRC |
| Rev No |
1 |
Status |
F |
Date |
07-07-2020 |
|
|
Cont ID |
|
| Sent By |
rrossano |
Date |
07-07-2020 |
Time |
|
Rev Time |
|
| Received By |
rrossano |
Date |
07-07-2020 |
Time |
|
Sent To |
|
|
| Notes |
| 2020-07-07 15:41:07 | 1. PLEASE RESPOND TO ALL COMMENTS IN WRITING, AND | | | INCLUDE PROJECT NAME, ADDRESS AND PERMIT NUMBER | | | (Z-XXXXXXXX). | | | 2. THE CITY OF WEST PALM BEACH HAS A NUMBER OF | | | REGULATIONS AND PERMIT REQUIREMENTS WHICH DIRECTLY | | | AFFECT THE DEVELOPMENT AND INSTALLATION OF WATER AND | | | WASTEWATER UTILITIES WITHIN THE CITY. PLEASE SEE | | | DEVELOPMENT PERMIT SUBMITTAL REQUIREMENTS AT THE LINK | | | BELOW: | | | HTTP://WPB.ORG/CMSPAGES/GETAMAZONFILE.ASPX?PATH=~\WPB_W | | | EBSITE\MEDIA\ENGINEERING\DEVELOPMENT-APPLICATION-FULL-P | | | ACKAGE_2016.PDF&HASH=7BD4DD7EB6115181D8C5977BCC02A97B19 | | | 60045731D3658206F27451722716EF | | | THIS AND OTHER RELATED ENGINEERING DOCUMENTS CAN BE | | | FOUND HERE: | | | HTTP://WPB.ORG/DEPARTMENTS/ENGINEERING-PUBLIC-WORKS/FOR | | | MS,-PERMITS-APPLICATIONS | | | ALSO SEE: CODE OF ORDINANCES, CITY OF WEST PALM BEACH, | | | FLORIDA, CODIFIED THROUGH ORD. NO. 4183-08, ADOPTED | | | SEPT. 22, 2008. (SUPPLEMENT NO. 18) | | | CHAPTER 90 UTILITIES, ARTICLE I. IN GENERAL, | | | SEC. 90-7. POLICY REGARDING EXTENSION OF WATER OR SEWER | | | SERVICE FACILITIES OF THE CITY. | | | 3. THE WATER AND WASTEWATER SERVICE AGREEMENTS AND THE | | | CONSTRUCTION PERMITS ADDRESS RESERVATION OF CAPACITY | | | BASED ON USAGE, METER SIZE AND FEES, DESIGN STANDARDS, | | | BACKFLOW PREVENTION, FIRE SERVICE AND IRRIGATION. | | | 4. PLEASE SUBMIT A FORMAL AS-BUILT REQUEST FOR ALL CITY | | | OF WEST PALM BEACH-OWNED UTILITIES WITHIN THE PUBLIC | | | RIGHT OF WAY FOR THE ENTIRE EXTENT OF THE LIMITS OF | | | YOUR PROJECT. IDENTIFY TYPE OF UTILITY, LOCATION, PIPE | | | MATERIAL, AGE AND SIZE. PLEASE CONTACT JANICE TARBILL | | | IN THE WPB ENGINEERING SERVICES DEPARTMENT AT | | | [email protected] OR 561-494-1079 FOR FURTHER | | | ASSISTANCE. NOTE THAT FIELD RECORDS ARE FOR INFORMATION | | | ONLY. FIELD VERIFY UTILITY LOCATIONS USING FIELD | | | SURVEY, POT-HOLING, SOFT DIGS ETC. | | | 5. AS OF DECEMBER 20, 2015, THE CITY OF WEST PALM BEACH | | | CROSS-CONNECTION CONTROL MANUAL HAS BEEN REVISED, | | | STATING "ALL BACKFLOW DEVICES MUST BE LEAD-FREE". FOR | | | MORE INFORMATION, REFER TO THE LINK BELOW: | | | HTTP://WPB.ORG/DEPARTMENTS/PUBLIC-UTILITIES/FORMS-PUBLI | | | CATIONS/BACKFLOW-CROSS-CONNECTION-CONTROL-MANUAL | | | 6. PLANS SHALL SHOW PROPOSED LOCATIONS AND DIMENSIONS | | | OF ALL WATER, STORM WATER, AND SANITARY AND SEWER | | | LINES, INCLUDING STUBS TO EACH PROPERTY LINE FOR WATER | | | AND SANITARY SEWERS, THE MAKE AND MODEL OF ALL VALVES, | | | METERS, AND OTHERS DEVICES TO BE INSTALLED ON THE | | | SYSTEM, CATCH BASINS, CULVERTS, DITCHES INCLUDING | | | GRADES, PIPES SIZES, MATERIALS, ELEVATIONS, | | | ASSUMPTIONS, CALCULATIONS, INVERT ELEVATIONS FOR ALL | | | INLETS AND MANHOLES AND PROFILES OF SANITARY SEWER | | | LINES. ALL AVAILABLE ELEVATION SHALL BE SHOWN ON THE | | | PROFILE VIEW. DIRECTION OF FLOW SHALL BE SHOWN ON PLAN | | | VIEW ON PLAN VIEW FOR ALL SANITARY AND STORM SEWERS. | | | ADDITIONALLY, PLAN VIEW SHALL SHOW ALL EXISTING AND | | | PROPOSED UNDERGROUND UTILITY LAYOUT, INCLUDING FIBER | | | OPTIC, ELECTRIC, GAS, AND CABLEVISION & | | | TELECOMMUNICATION FACILITIES LOCATED ON THE | | | RIGHT-OF-WAY. PROVIDE PROFILE AND CLEARANCES AT ALL | | | UTILITY CROSSINGS. CUT AND CAP UTILITIES NOT IN USE, | | | AND REMOVE ANY ABANDONED UTILITY LINES LARGER THAN 2 | | | INCHES FROM CITY RIGHT OF WAY. | | | 7. PLEASE SUBMIT COMPLETED LOS ANALYSIS SUMMARY TABLE | | | DIRECTLY TO ENGINEERING (SHEET 33 OF CITY OF WPB | | | DEVELOPMENT APPLICATION). | | | 8. WHEN PROPOSED, WATER MAINS IN CITY RIGHT OF WAY | | | SHALL BE MADE OF DUCTILE IRON PIPE (NOT PVC) AND | | | SPECIFY PROPOSED LENGTH IN FEET. | | | 9. PLEASE COORDINATE PLACEMENT OF WATER METERS/BACKFLOW | | | PREVENTION ETC. WITH MARK HURLEY OF PUBLIC UTILITIES | | | CUSTOMER SERVICE AT 561-822-2262 OR [email protected]. | | | 10. PLEASE CALLOUT DOMESTIC BACKFLOW PREVENTER AS RPPA | | | AND FIRE BACKFLOW PREVENTER AS DCDA. | | | 11. PLEASE PROVIDE ENLARGED VIEW ON PLANS OF PROPOSED | | | LOCATION OF WATER METER AND BACKFLOW PREVENTION. | | | 12. PROVIDE VERTICAL DATUM AND DATUM CONVERSION | | | INFORMATION (NAVD 1988 AND NGVD 1929). | | | 13. PROVIDE CALCULATIONS ON PLANS OF EXISTING AND | | | PROPOSED DEMANDS FOR WATER & SEWER (AVERAGE, MAXIMUM | | | AND PEAK) AND FIRE FLOW DEMANDS. CALCULATIONS SHALL BE | | | PER FAC 64E-6 FOR SEWER AND PER FAC 64-E.008 FOR WATER. | | | 14. PROVIDE CCTV VIDEO OF EXISTING SANITARY SEWER AND | | | STORMWATER INFRASTRUCTURE ALONG ENTIRE PROJECT | | | FRONTAGE. | | | 15. CHECK TO SEE IF FDEP FORMS FOR PROPOSED SANITARY | | | SEWER ARE REQUIRED. | | | 16. PLEASE PROVIDE CLEANOUTS FOR PROPOSED SANITARY LINE | | | ONSITE JUST INSIDE PROPERTY LINE, AT JOINTS AND EVERY | | | 75 FEET. | | | 17. FOR FORMAL ENGINEERING SUBMITTAL, SFWMD ERP AND | | | NPDES NOI REQUIREMENTS WILL BE ENFORCED. | | | - AN NOI IS REQUIRED FOR PROJECTS THAT: | | | - 1) DISTURB ONE OF MORE ACRES OF LAND OR DISTURB LESS | | | THAN ON ACRE OF LAND BUT ARE PART OF A COMMON PLAN OF | | | DEVELOPMENT OR SALE; | | | - 2) DISCHARGE STORMWATER TO SURFACE WATERS OF THE | | | STATE OR TO SURFACE WATERS OF THE STATE THROUGH A | | | MUNICIPAL SEPARATE STORM SEWER SYSTEM (MS4). | | | - THE SFWMD ERP CAN BE OBTAINED THROUGH A 10-2 SELF | | | CERTIFICATION THROUGH FDEP OR AN ERP APPLICATION | | | THROUGH SFWMD. EITHER WAY, THE DEVELOPER/ENGINEER SHALL | | | SUBMIT A COPY OF THE ERP PERMIT OR FDEP ACKNOWLEDGEMENT | | | OF THE 10-2 CERTIFICATION. | | | 18. FOR FORMAL ENGINEERING SUBMITTAL, PLEASE PROVIDE | | | EASEMENT FOR PLACEMENT OF PROPOSED WATER METERS. | | | 19. FOR FORMAL ENGINEERING SUBMITTAL, PROVIDE PROFILES | | | OF WATER AND SEWER AND SHOW ANY CROSSINGS/CONFLICTS. | | | 20. FOR FORMAL ENGINEERING SUBMITTAL, WHEN SUBMITTING | | | APPROVED MATERIALS LIST, PLEASE PROVIDE MATERIAL/CUT | | | SHEETS FOR ALL PROPOSED BACKFLOW DEVICES SHOWING | | | SPECIFIC MODEL NUMBER AND SPECIFYING USC APPROVED | | | LEAD-FREE DESIGN. | | | 21. FOR FORMAL ENGINEERING SUBMITTAL, IF SANITARY LINES | | | ARE PROPOSED IN ROW PLEASE SHOW ADJACENT SANITARY | | | LATERAL LOCATIONS AND SHOW ADDRESSES OF ADJACENT | | | PARCELS. | | | 22. FOR FORMAL ENGINEERING SUBMITTAL, IF WATER LINES | | | ARE BEING REPLACED IN ROW, SHOW ADJACENT PARCEL | | | ADDRESSES. | | | 23. FOR FORMAL ENGINEERING SUBMITTAL, ADD NOTE TO | | | PROVIDE 50 FT. PAVEMENT RESTORATION TRANSITION ON EACH | | | SIDE OF PROPOSED TRENCH IN CITY MAINTAINED ROADWAY | | | AREAS PER CITY OF WPB STANDARD DETAIL GC-8. | | | 24. FOR FORMAL ENGINEERING SUBMITTAL, SHOW DIMENSIONS | | | OF PROPOSED DUMPSTER PER CURRENT CITY OF WPB STANDARD | | | DETAIL GC-7. | | | 25. FOR FORMAL ENGINEERING SUBMITTAL, PLEASE PROVIDE | | | CALCULATIONS OF PERVIOUS AND IMPERVIOUS AREAS FOR | | | PROPOSED IMPROVED AREAS. | | | | | | THE FOLLOWING COMMENTS ARE FROM HONG XU, PROJECT | | | ENGINEER, PUBLIC UTILITIES, 561-494-1047, [email protected]: | | | | | | NEED TO SHOW WATER SERVICE AND SANITARY SEWER LATERAL | | | CONNECTIONS ON THE PLAN. IT SAYS SEE PLUMBING PLANS FOR | | | CONNECTIONS. BUT THE PLUMBING PLANS ARE NOT PROVIDED IN | | | THE SUBMITTAL. | | | FEEL FREE TO CONTACT US IF YOU HAVE ANY QUESTIONS OR | | | CONCERNS, THANKS. | | | | | | ADDITIONAL COMMENTS ADDED JULY 13, 2020 FROM MARK | | | HURLEY, CUSTOMER SERVICE SUPERVISOR, CITY OF WPB PUBLIC | | | UTILITIES, [email protected], 561-822-2262: | | | | | | -THE OLD METER FOR THE PROPERTY IS 3/4 IN. AND ACCOUNT | | | IS NOT ACTIVE. PLAN DESIGNER WOULD NEED TO DETERMINE IF | | | THE 3/4 IN. METER WILL BE SUFFICIENT FOR THE WATER | | | DEMAND OR IF IT NEEDS TO BE UPSIZED TO 1 IN. METER. | | | WILL HAVE TO WORK WITH OUR UTILITY BILLING DEPT TO | | | DETERMINE THE COSTS INVOLVED EITHER WAY. | | | -PLEASE ADD WATER DEMAND CALCULATIONS TO PLAN. | | | -THE 2 IN. LINE CURRENTLY HAS A 1.5 IN. METER. IT LOOKS | | | TO BE AN ACTIVE PARKS IRRIGATION METER. WE WOULD HAVE | | | TO VERIFY WITH PARKS IF THEY ARE USING IT AND WHAT IT | | | SERVES (MAY WATER THE ROW GRASS). IF IT IS NOT | | | AVAILABLE, THEN MAY HAVE TO GET NEW LINE, TAP, & METER. | | | IF AVAILABLE PLAN DESIGNER WOULD NEED TO DETERMINE IF | | | 1.5 IN. METER IS SUFFICIENT FOR DEMAND OR IF NEED | | | UPSIZE TO 2 IN. METER. SAME WITH UTILITY BILLING. | | | -PLAN DRAWINGS FOR THE WATER LINES DO NOT MATCH THE | | | HISTORIC DRAWINGS WITH THE 4 IN. WATER MAIN BRANCH | | | ACROSS 15TH ST AND E-W SERVICE LINES. THEY NEED TO BE | | | VERIFIED IN THE FIELD AND PLAN UPDATED AS NEEDED. | | | -PLEASE REFERENCE THE WS STANDARD DETAILS FOR THE | | | BACKFLOW ASSEMBLIES AND USE RP TYPE ASSEMBLIES. | | | DEPENDING ON METHOD, MAY HAVE TO BORE UNDER SIDEWALK OR | | | CUT IT OUT TO PLACE NEW PIPING AND SLEEVE UNDER | | | SIDEWALK. | | | -LOOKS LIKE NEW HYDRANT BEING INSTALLED NEAR NW CORNER | | | OF PROPERTY. NEED LABEL TO MAKE THAT MORE CLEAR AND THE | | | TEE DOES NOT LOOK LIKE IT IS DRAWN ONTO THE CORRECT | | | PIPING. PLEASE ALSO MOVE VALVE IN SIDEWALK EAST OUT OF | | | THE SIDEWALK. | | | | | | | | | RICK ROSSANO, PROJECT COORDINATOR, ENGINEERING SERVICES | | | DEPARTMENT | | | 401 CLEMATIS STREET, 4TH FLOOR, WEST PALM BEACH, FL | | | 33401 | | | DIRECT: (561) 494-1098, FAX: (561) 494-1116, MOBILE: | | | (561) 246-9525 | | | EMAIL: [email protected] | | | WWW.WPB.ORG/ENGINEERING | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
07-02-2020 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
07-02-2020 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
07-02-2020 |
Time |
16:24 |
Sent To |
|
|
| Notes |
| 2020-07-02 16:28:03 | THE FOLLOWING COMMENTS WERE SUBMITTED BY PETER LEDUC, | | | FIRE MARSHAL, BUREAU OF FIRE PREVENTION, WEST PALM | | | BEACH FIRE RESCUE. | | | | | | THIS REVIEW CAN ONLY BE CONSIDERED PRELIMINARY AS THE | | | DRAWINGS THAT WERE REVIEWED WERE NOT COMPLETE. | | | ADDITIONAL COMMENTS CAN BE EXPECTED WHEN FULL DRAWINGS | | | ARE SUBMITTED FOR PERMIT. | | | | | | THE FIRE PREVENTION BUREAU HAS NO OBJECTIONS TO THE | | | PROPOSED PROJECT. | | | | | | 1. CONSTRUCTION, DEMOLITION, AND RENOVATION TO COMPLY | | | WITH NFPA 241. EXTRA ATTENTION SHALL BE GIVEN TO THE | | | PERMITTING AND LOCATION OF CONSTRUCTION TRAILERS. A | | | PERMIT IS REQUIRED FOR ANY CONSTRUCTION TRAILER RELATED | | | TO THIS PROJECT. SEPARATION DISTANCES FROM MAIN | | | STRUCTURES AS WELL AS OTHER TRAILERS SHALL BE CLOSELY | | | MONITORED FOR THE REQUIREMENTS OF FIRE SPRINKLER | | | PROTECTION. | | | | | | 2. SITE ACCESS AND EXIT POINTS ARE TO BE CLEARLY | | | IDENTIFIED AND MAINTAINED FOR EMERGENCY VEHICLES DURING | | | ALL CONSTRUCTION ACTIVITIES. | | | | | | 3. THE BUILDING ADDRESS SHALL BE CLEARLY VISIBLE FROM | | | ALL ACCESS ROADWAYS, INCLUDING DURING CONSTRUCTION. | | | ADDRESS NUMBERS SHALL CONTRAST WITH THEIR BACKGROUND | | | AND SHALL NOT BE LESS THAN SIX (6) INCHES IN HEIGHT | | | WITH A ONE (1) INCH STROKE FOR ALL BUILDINGS. | | | | | | 4. DURING CONSTRUCTION, TRASH AND DEBRIS IS TO BE | | | REMOVED FROM THE SITE DAILY OR MORE OFTEN TO REDUCE THE | | | ACCUMULATION OF POTENTIAL LIFE AND FIRE SAFETY HAZARDS. | | | | | | 5. THE CONSTRUCTION OF THE BUILDING SHALL COMPLY WITH | | | THE 6TH EDITION OF THE FLORIDA FIRE PREVENTION CODE, | | | INCLUDING NFPA 1 & 101, AND ALL ASSOCIATED FIRE CODES. | | | | | | 6. FOR PLAN REVIEW SUBMITTAL, PLEASE INCLUDE THE | | | OCCUPANCY TYPE, PER THE FLORIDA FIRE PREVENTION CODE. | | | | | | 7. FOR PLAN REVIEW SUBMITTAL, PLEASE ENSURE THAT A FIRE | | | LOAD CALCULATION IS INCLUDED AND THAT ADEQUATE WATER | | | SUPPLY IS EXISTING OR WILL BE PROVIDED. | | | | | | 8. ALL EXISTING AND NEW FIRE HYDRANTS PLANNED FOR THIS | | | DEVELOPMENT SHALL BE CLEARLY INDICATED AND IDENTIFIED | | | ON THE PLAN AND CLOSELY COORDINATED WITH THE BUREAU OF | | | FIRE PREVENTION. | | | | | | THE PROPOSED LOCATIONS OF THE FIRE HYDRANT IS | | | ACCEPTABLE WITH ANY CHANGES CLOSELY COORDINATED WITH | | | THE BUREAU OF FIRE PREVENTION. | | | | | | 9. PROVIDE FOR A FIRE SPRINKLER AND/OR FIRE ALARM PER | | | THE APPLICABLE OCCUPANCY CODE. FOR ANY LIFE SAFETY | | | ENGINEERED SYSTEM, I.E FIRE SPRINKLER AND FIRE ALARM, | | | ENSURE THEY COMPLY WITH THE REQUIREMENTS OF FS 61G AND | | | SUBMITTED WITH THE MASTER PERMIT. | | | | | | 9A) THE LOCATION OF ANY APPLICABLE DDCV AND FIRE LINE | | | LOCATIONS SHALL MEET THE REQUIREMENTS OF NFPA 24 AND | | | SHALL BE COORDINATED WITH THE OFFICE OF FIRE MARSHAL, | | | THE CITY'S ENGINEERS OFFICE, THE LANDSCAPE PLANNER, AND | | | THE CITY'S PLANNING AND ZONING OFFICE. | | | | | | 10. COMPLETE LIFE SAFETY PLANS FOR THE OCCUPANCY SHALL | | | BE PROVIDED THAT ILLUSTRATE OCCUPANT LOADS, TRAVEL | | | DISTANCES, COMMON PATHS OF TRAVEL, DEAD-END CORRIDORS, | | | EXIT SIGNS, EMERGENCY LIGHTING, EXITS LEADING TO A | | | PUBLIC WAY, FIRE EXTINGUISHER LOCATIONS, AND ALL FIRE | | | SAFETY FEATURES AND EQUIPMENT. | | | | | | 11. IT IS HIGHLY RECOMMENDED (REQUIRED WITH FIRE | | | SPRINKLER SYSTEM) THAT A KNOX BOX WITH KEYS FOR ENTRY | | | DOOR LOCKS BE PROVIDED FOR 24 HOUR EMERGENCY ACCESS. | | | | | | 12. THE BUREAU'S APPROVAL OF THIS SUBMITTED PROJECT | | | DOES NOT CONSTITUTE ITS FINAL REVIEW OR APPROVAL. | | | | | | 13. THE BUREAU SHALL REVIEW ALL SUBMITTED BUILDING | | | PLANS AT THE APPROPRIATE TIME AND IN ACCORDANCE WITH | | | THE REQUIREMENTS OF ALL APPLICABLE CODES AND STANDARDS. | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
4 |
Status |
P |
Date |
11-03-2020 |
|
|
Cont ID |
|
| Sent By |
rcaranci |
Date |
11-03-2020 |
Time |
14:21 |
Rev Time |
0.00 |
| Received By |
rcaranci |
Date |
11-03-2020 |
Time |
14:21 |
Sent To |
|
|
| Notes |
| 2020-11-03 14:21:29 | FROM: RAY CARANCI, SENIOR LANDSCAPE PLANNER | | | 561-822-1462 | | | PROJECT: 1600 N AUSTRALIAN Z20060015 | | | NOVEMBER 3, 2020 | | | I HAVE REVIEWED THE ABOVE REFERENCED PETITION, AND | | | PROVIDE THE FOLLOWING COMMENTS: | | | | | | | | | 1. MAKE THE FOLLOWING CORRECTIONS TO THE TREE | | | DISPOSITION PLAN SHEET 1 OF 1. | | | ? SATISFIED. COLUMN FOR CONDITION MUST BE INCLUDED IN | | | THE CHART. | | | ? SATISFIED. GIVE THE CONDITION OF EACH TREE. | | | ? SATISFIED. INCLUDE CANOPY DIAMETER MEASUREMENT FOR | | | TREES IN ORDER TO CALCULATE MITIGATION DUE IF REMOVED. | | | ? SATISFIED. CANOPY SQUARE FOOTAGE FOR MITIGATION DUE | | | FOR ANY TREES PROPOSED FOR REMOVAL MUST BE IN A | | | SEPARATE COLUMN, AND THE TOTAL PROVIDED FOR THE COLUMN. | | | ? SATISFIED. REMOVALS OF PALMS MUST INCLUDE THE | | | MITIGATION REQUIRED BY CATEGORY. | | | QUEEN PALM 112 AND 5 CHINESE FAN PALMS ARE CATEGORY 4 | | | MITIGATION REQUIRED 50 SQ FT EACH FOR A TOTAL OF 300 SQ | | | FT PLUS 706 FOR JACARANDA. TOTAL IS 1006 SQ FT. UPDATE | | | CANOPY REPLACEMENT COLUMN AND TOTAL. | | | ? SATISFIED. INCLUDE A CHART FOR TREE MITIGATION | | | PROVIDED BASED ON THE PLANT LIST AND PROVIDE THE TOTAL | | | FOR THE SQUARE FOOTAGE. | | | INCLUDE ALL TREES ADDED ON LANDSCAPE PLAN AND TOTAL | | | CANOPY SQ FT CREDIT. | | | | | | 2. SATISFIED. SECTION 94-448 (D)(3) REQUIRES NATIVE | | | TREES IN GOOD CONDITION TO BE PRESERVED ON SITE OR | | | RELOCATED. ANSI A 300 (PART 5) STANDARDS SPECIFY | | | EXAMPLES OF SUITABILITY RATINGS OF GOOD, MODERATE, OR | | | POOR FOR RELOCATION. PROVIDE CONDITION AND RELOCATION | | | POTENTIAL FOR THE NATIVE SABAL PALMS. | | | | | | 3. SATISFIED. CITY POLICY REQUIRES THE USE OF FLORIDA | | | NATIVE SPECIES WHEN POSSIBLE. THERE ARE NATIVE | | | ALTERNATIVES FOR CARRISSA, PODOCARPUS, AND PITTOSPORUM. | | | | | | IT WOULD BE BETTER TO HAVE 100% NATIVE IF POSSIBLE. | | | PREFERRED TO HAVE SPECIES THAT REQUIRE NO FERTILIZER | | | BECAUSE THEY WILL NOT RECEIVE IT. | | | | | | 4. SATISFIED. CHECK THE FLORIDA FRIENDLY DESIGN OPTIONS | | | LIST AND SEE IF MORE POINTS CAN BE ADDED THROUGH NATIVE | | | TREES AND SHRUBS. THE ADDITIONAL SHADE TREES IN | | | VEHICULAR USE AREAS MUST BE VERIFIED IF CLAIMED. | | | PLEASE TAKE CREDITS FOR NATIVE TREES AND SHRUBS FIRST. | | | | | | 5. SATISFIED. ADJUST THE CALCULATIONS FOR MINIMUM SHADE | | | TREE AND FLOWERING TREE REQUIREMENTS PER SECTION | | | 94-443(C)(2)B. BASED ON REQUIRED OPEN SPACE OF 14793 SQ | | | FT. SHADE TREES-10, FLOWERING TREES -3, SHRUBS -30. | | | FLOWERING TREE CATEGORY IS MISSING. | | | | | | 6. SATISFIED. ADD RELOCATED PALMS TO THE PLANT LIST AND | | | COUNT THEM TOWARD THE REQUIRED TREES. | | | | | | NOT CLEAR IF SABALS LABELED EXISTING ARE RELOCATED. ADD | | | THE OTHER EXISTING TREES TO REMAIN TO THE PLANT LIST. | | | | | | 7. SATISFIED. MINIMUM TREE SIZES ARE 12 FEET, AND PALMS | | | 8 FOOT CLEAR TRUNK. MAKE CORRECTIONS. | | | | | | 8. SATISFIED. PROVIDE A PLAN SHOWING THE PARKING | | | LANDSCAPE AREAS COUNTED TOWARD COMPLIANCE WITH SECTION | | | 94-443(C)(3) AND (4) AND PROVIDE CALCULATIONS. | | | CALCULATE SQUARE FOOTAGE REQUIRED PER CODES REFERENCED | | | AND SHOW WHERE IT IS PROVIDED WITHIN THE PARKING AREA. | | | | | | 9. SATISFIED. SECTION 94-443(C)(3) REQUIRES THAT A | | | MINIMUM OF 75 PERCENT OF ALL TREES THAT ARE REQUIRED TO | | | BE PLANTED WITHIN THE INTERIOR OF AN OFF STREET PARKING | | | AREA SHALL BE CATEGORY 1 SHADE TREES. SHOW THE | | | PERCENTAGE OF CATEGORY 1 TREES PROVIDED FOR THE | | | REQUIRED LANDSCAPE AREAS. | | | | | | 10. SATISFIED. PROVIDE CALCULATIONS FOR REQUIRED BUFFER | | | TREES AT ONE FOR EVERY 30 FEET OR PORTION THEREOF FOR | | | EACH BUFFER LENGTH, AND SHOW THE NUMBER PROVIDED. | | | SEPARATE NORTH, SOUTH EAST AND WEST LENGTHS AND SHOW | | | REQUIRED AND PROVIDED TREES FOR EACH. | | | WEST BUFFER IS 11 REQUIRED 11 PROVIDED. THIS CAN BE | | | CORRECTED | | | | | | 11. SATISFIED. THERE ARE TERMINAL LANDSCAPE ISLANDS | | | THAT DO NOT MEET THE 8 FEET LANDSCAPE AREA REQUIRED | | | INSIDE THE CURB. REVISE. | | | | | | | | | 12. SATISFIED. THERE APPEAR TO BE CONFLICTS IN SEVERAL | | | LOCATIONS BETWEEN TREES AND WATER AND SEWER LINES ON | | | THE LANDSCAPE PLAN. ADJUST LOCATIONS OF TREES OR | | | UTILITY LINES TO RESOLVE CONFLICTS WITH LANDSCAPING. | | | | | | 13. SATISFIED. SHOW COMPLIANCE WITH SECTION 94-445 L. | | | PLANT SPECIES. A MINIMUM OF 60 PERCENT OF PLANT | | | MATERIAL ADDED SHALL BE FLORIDA NATIVE OR DROUGHT | | | TOLERANT SPECIES SELECTED FROM THE CITY LIST OR THE | | | LIST OF SPECIES IN THE MOST RECENT EDITION OF SOUTH | | | FLORIDA WATER MANAGEMENT DISTRICT WATERWISE SOUTH | | | FLORIDA LANDSCAPES. PROVIDE THE ACTUAL PERCENTAGE BASED | | | ON THE PLANT LIST. | | | | | | ADDITIONAL COMMENTS 8/27/20: | | | 14. SATISFIED REMOVE SKY CLIMBER CULTIVAR AND INDICATE | | | SPECIES LIVE OAK. | | | | | | 15. SATISFIED SEPARATE TREES AND SHRUBS ON THE PLANT | | | LIST PROVIDED FOR THE NORTH PROPERTY. | | | | | | CONDITIONS OF APPROVAL | | | 1. PRIOR TO THE REMOVAL OR RELOCATION OF ANY TREES ON | | | THE PROPERTY, A TREE ALTERATION PERMIT SHALL BE | | | SUBMITTED, REVIEWED AND APPROVED BY THE DEVELOPMENT | | | SERVICES DEPARTMENT, PLANNING DIVISION. | | | |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
3 |
Status |
F |
Date |
10-22-2020 |
|
|
Cont ID |
|
| Sent By |
rcaranci |
Date |
10-22-2020 |
Time |
15:51 |
Rev Time |
0.00 |
| Received By |
rcaranci |
Date |
10-22-2020 |
Time |
15:51 |
Sent To |
|
|
| Notes |
| 2020-10-22 15:53:51 | FROM: RAY CARANCI, SENIOR LANDSCAPE PLANNER | | | 561-822-1462 | | | PROJECT: 1600 N AUSTRALIAN Z20060015 | | | OCTOBER 22, 2020 | | | I HAVE REVIEWED THE ABOVE REFERENCED PETITION, AND | | | PROVIDE THE FOLLOWING COMMENTS: | | | | | | 1. MAKE THE FOLLOWING CORRECTIONS TO THE TREE | | | DISPOSITION PLAN SHEET 1 OF 1. | | | ? SATISFIED. COLUMN FOR CONDITION MUST BE INCLUDED IN | | | THE CHART. | | | ? SATISFIED. GIVE THE CONDITION OF EACH TREE. | | | ? SATISFIED. INCLUDE CANOPY DIAMETER MEASUREMENT FOR | | | TREES IN ORDER TO CALCULATE MITIGATION DUE IF REMOVED. | | | ? SATISFIED. CANOPY SQUARE FOOTAGE FOR MITIGATION DUE | | | FOR ANY TREES PROPOSED FOR REMOVAL MUST BE IN A | | | SEPARATE COLUMN, AND THE TOTAL PROVIDED FOR THE COLUMN. | | | ? PARTIALLY SATISFIED. REMOVALS OF PALMS MUST INCLUDE | | | THE MITIGATION REQUIRED BY CATEGORY. | | | QUEEN PALM 112 AND 5 CHINESE FAN PALMS ARE CATEGORY 4 | | | MITIGATION REQUIRED 50 SQ FT EACH FOR A TOTAL OF 300 SQ | | | FT PLUS 706 FOR JACARANDA. TOTAL IS 1006 SQ FT. UPDATE | | | CANOPY REPLACEMENT COLUMN AND TOTAL. | | | ? PARTIALLY SATISFIED. INCLUDE A CHART FOR TREE | | | MITIGATION PROVIDED BASED ON THE PLANT LIST AND PROVIDE | | | THE TOTAL FOR THE SQUARE FOOTAGE. | | | INCLUDE ALL TREES ADDED ON LANDSCAPE PLAN AND TOTAL | | | CANOPY SQ FT CREDIT. | | | | | | 2. SATISFIED. SECTION 94-448 (D)(3) REQUIRES NATIVE | | | TREES IN GOOD CONDITION TO BE PRESERVED ON SITE OR | | | RELOCATED. ANSI A 300 (PART 5) STANDARDS SPECIFY | | | EXAMPLES OF SUITABILITY RATINGS OF GOOD, MODERATE, OR | | | POOR FOR RELOCATION. PROVIDE CONDITION AND RELOCATION | | | POTENTIAL FOR THE NATIVE SABAL PALMS. | | | | | | 3. PARTIALLY SATISFIED. CITY POLICY REQUIRES THE USE OF | | | FLORIDA NATIVE SPECIES WHEN POSSIBLE. THERE ARE NATIVE | | | ALTERNATIVES FOR CARRISSA, PODOCARPUS, AND PITTOSPORUM. | | | | | | IT WOULD BE BETTER TO HAVE 100% NATIVE IF POSSIBLE. | | | PREFERRED TO HAVE SPECIES THAT REQUIRE NO FERTILIZER | | | BECAUSE THEY WILL NOT RECEIVE IT. | | | | | | 4. PARTIALLY SATISFIED. CHECK THE FLORIDA FRIENDLY | | | DESIGN OPTIONS LIST AND SEE IF MORE POINTS CAN BE ADDED | | | THROUGH NATIVE TREES AND SHRUBS. THE ADDITIONAL SHADE | | | TREES IN VEHICULAR USE AREAS MUST BE VERIFIED IF | | | CLAIMED. | | | PLEASE TAKE CREDITS FOR NATIVE TREES AND SHRUBS FIRST. | | | | | | 5. SATISFIED. ADJUST THE CALCULATIONS FOR MINIMUM SHADE | | | TREE AND FLOWERING TREE REQUIREMENTS PER SECTION | | | 94-443(C)(2)B. BASED ON REQUIRED OPEN SPACE OF 14793 SQ | | | FT. SHADE TREES-10, FLOWERING TREES -3, SHRUBS -30. | | | FLOWERING TREE CATEGORY IS MISSING. | | | | | | 6. PARTIALLY SATISFIED. ADD RELOCATED PALMS TO THE | | | PLANT LIST AND COUNT THEM TOWARD THE REQUIRED TREES. | | | | | | NOT CLEAR IF SABALS LABELED EXISTING ARE RELOCATED. ADD | | | THE OTHER EXISTING TREES TO REMAIN TO THE PLANT LIST. | | | | | | 7. SATISFIED. MINIMUM TREE SIZES ARE 12 FEET, AND PALMS | | | 8 FOOT CLEAR TRUNK. MAKE CORRECTIONS. | | | | | | 8. SATISFIED. PROVIDE A PLAN SHOWING THE PARKING | | | LANDSCAPE AREAS COUNTED TOWARD COMPLIANCE WITH SECTION | | | 94-443(C)(3) AND (4) AND PROVIDE CALCULATIONS. | | | CALCULATE SQUARE FOOTAGE REQUIRED PER CODES REFERENCED | | | AND SHOW WHERE IT IS PROVIDED WITHIN THE PARKING AREA. | | | | | | 9. SATISFIED. SECTION 94-443(C)(3) REQUIRES THAT A | | | MINIMUM OF 75 PERCENT OF ALL TREES THAT ARE REQUIRED TO | | | BE PLANTED WITHIN THE INTERIOR OF AN OFF STREET PARKING | | | AREA SHALL BE CATEGORY 1 SHADE TREES. SHOW THE | | | PERCENTAGE OF CATEGORY 1 TREES PROVIDED FOR THE | | | REQUIRED LANDSCAPE AREAS. | | | | | | 10. PARTIALLY SATISFIED. PROVIDE CALCULATIONS FOR | | | REQUIRED BUFFER TREES AT ONE FOR EVERY 30 FEET OR | | | PORTION THEREOF FOR EACH BUFFER LENGTH, AND SHOW THE | | | NUMBER PROVIDED. | | | SEPARATE NORTH, SOUTH EAST AND WEST LENGTHS AND SHOW | | | REQUIRED AND PROVIDED TREES FOR EACH. | | | | | | 11. SATISFIED. THERE ARE TERMINAL LANDSCAPE ISLANDS | | | THAT DO NOT MEET THE 8 FEET LANDSCAPE AREA REQUIRED | | | INSIDE THE CURB. REVISE. | | | | | | | | | 12. SATISFIED. THERE APPEAR TO BE CONFLICTS IN SEVERAL | | | LOCATIONS BETWEEN TREES AND WATER AND SEWER LINES ON | | | THE LANDSCAPE PLAN. ADJUST LOCATIONS OF TREES OR | | | UTILITY LINES TO RESOLVE CONFLICTS WITH LANDSCAPING. | | | | | | 13. SATISFIED. SHOW COMPLIANCE WITH SECTION 94-445 L. | | | PLANT SPECIES. A MINIMUM OF 60 PERCENT OF PLANT | | | MATERIAL ADDED SHALL BE FLORIDA NATIVE OR DROUGHT | | | TOLERANT SPECIES SELECTED FROM THE CITY LIST OR THE | | | LIST OF SPECIES IN THE MOST RECENT EDITION OF SOUTH | | | FLORIDA WATER MANAGEMENT DISTRICT WATERWISE SOUTH | | | FLORIDA LANDSCAPES. PROVIDE THE ACTUAL PERCENTAGE BASED | | | ON THE PLANT LIST. | | | | | | ADDITIONAL COMMENTS 8/27/20: | | | 14. SATISFIED REMOVE SKY CLIMBER CULTIVAR AND INDICATE | | | SPECIES LIVE OAK. | | | | | | 15. SATISFIED SEPARATE TREES AND SHRUBS ON THE PLANT | | | LIST PROVIDED FOR THE NORTH PROPERTY. | | | | | | CONDITIONS OF APPROVAL | | | 1. PRIOR TO THE REMOVAL OR RELOCATION OF ANY TREES ON | | | THE PROPERTY, A TREE ALTERATION PERMIT SHALL BE | | | SUBMITTED, REVIEWED AND APPROVED BY THE DEVELOPMENT | | | SERVICES DEPARTMENT, PLANNING DIVISION. | | | |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
2 |
Status |
F |
Date |
08-28-2020 |
|
|
Cont ID |
|
| Sent By |
rcaranci |
Date |
08-28-2020 |
Time |
10:07 |
Rev Time |
0.00 |
| Received By |
rcaranci |
Date |
08-28-2020 |
Time |
10:07 |
Sent To |
|
|
| Notes |
| 2020-08-28 10:09:17 | FROM: RAY CARANCI, SENIOR LANDSCAPE PLANNER | | | 561-822-1462 | | | PROJECT: 1600 N AUSTRALIAN Z20060015 | | | AUGUST 27, 2020 | | | I HAVE REVIEWED THE ABOVE REFERENCED PETITION, AND | | | PROVIDE THE FOLLOWING COMMENTS: | | | | | | 1. MAKE THE FOLLOWING CORRECTIONS TO THE TREE | | | DISPOSITION PLAN SHEET 1 OF 1. | | | ? SATISFIED. COLUMN FOR CONDITION MUST BE INCLUDED IN | | | THE CHART. | | | ? SATISFIED. GIVE THE CONDITION OF EACH TREE. | | | ? SATISFIED. INCLUDE CANOPY DIAMETER MEASUREMENT FOR | | | TREES IN ORDER TO CALCULATE MITIGATION DUE IF REMOVED. | | | ? SATISFIED. CANOPY SQUARE FOOTAGE FOR MITIGATION DUE | | | FOR ANY TREES PROPOSED FOR REMOVAL MUST BE IN A | | | SEPARATE COLUMN, AND THE TOTAL PROVIDED FOR THE COLUMN. | | | ? PARTIALLY SATISFIED. REMOVALS OF PALMS MUST INCLUDE | | | THE MITIGATION REQUIRED BY CATEGORY. | | | QUEEN PALM 112 AND 5 CHINESE FAN PALMS ARE CATEGORY 4 | | | MITIGATION REQUIRED 50 SQ FT EACH FOR A TOTAL OF 300 SQ | | | FT PLUS 706 FOR JACARANDA. TOTAL IS 1006 SQ FT. UPDATE | | | CANOPY REPLACEMENT COLUMN AND TOTAL. | | | ? PARTIALLY SATISFIED. INCLUDE A CHART FOR TREE | | | MITIGATION PROVIDED BASED ON THE PLANT LIST AND PROVIDE | | | THE TOTAL FOR THE SQUARE FOOTAGE. | | | INCLUDE ALL TREES ADDED ON LANDSCAPE PLAN AND TOTAL | | | CANOPY SQ FT CREDIT. | | | | | | 2. SATISFIED. SECTION 94-448 (D)(3) REQUIRES NATIVE | | | TREES IN GOOD CONDITION TO BE PRESERVED ON SITE OR | | | RELOCATED. ANSI A 300 (PART 5) STANDARDS SPECIFY | | | EXAMPLES OF SUITABILITY RATINGS OF GOOD, MODERATE, OR | | | POOR FOR RELOCATION. PROVIDE CONDITION AND RELOCATION | | | POTENTIAL FOR THE NATIVE SABAL PALMS. | | | | | | 3. PARTIALLY SATISFIED. CITY POLICY REQUIRES THE USE OF | | | FLORIDA NATIVE SPECIES WHEN POSSIBLE. THERE ARE NATIVE | | | ALTERNATIVES FOR CARRISSA, PODOCARPUS, AND PITTOSPORUM. | | | | | | IT WOULD BE BETTER TO HAVE 100% NATIVE IF POSSIBLE. | | | PREFERRED TO HAVE SPECIES THAT REQUIRE NO FERTILIZER | | | BECAUSE THEY WILL NOT RECEIVE IT. | | | | | | 4. PARTIALLY SATISFIED. CHECK THE FLORIDA FRIENDLY | | | DESIGN OPTIONS LIST AND SEE IF MORE POINTS CAN BE ADDED | | | THROUGH NATIVE TREES AND SHRUBS. THE ADDITIONAL SHADE | | | TREES IN VEHICULAR USE AREAS MUST BE VERIFIED IF | | | CLAIMED. | | | PLEASE TAKE CREDITS FOR NATIVE TREES AND SHRUBS FIRST. | | | | | | 5. SATISFIED. ADJUST THE CALCULATIONS FOR MINIMUM SHADE | | | TREE AND FLOWERING TREE REQUIREMENTS PER SECTION | | | 94-443(C)(2)B. BASED ON REQUIRED OPEN SPACE OF 14793 SQ | | | FT. SHADE TREES-10, FLOWERING TREES -3, SHRUBS -30. | | | FLOWERING TREE CATEGORY IS MISSING. | | | | | | 6. PARTIALLY SATISFIED. ADD RELOCATED PALMS TO THE | | | PLANT LIST AND COUNT THEM TOWARD THE REQUIRED TREES. | | | | | | NOT CLEAR IF SABALS LABELED EXISTING ARE RELOCATED. ADD | | | THE OTHER EXISTING TREES TO REMAIN TO THE PLANT LIST. | | | | | | 7. SATISFIED. MINIMUM TREE SIZES ARE 12 FEET, AND PALMS | | | 8 FOOT CLEAR TRUNK. MAKE CORRECTIONS. | | | | | | 8. SATISFIED. PROVIDE A PLAN SHOWING THE PARKING | | | LANDSCAPE AREAS COUNTED TOWARD COMPLIANCE WITH SECTION | | | 94-443(C)(3) AND (4) AND PROVIDE CALCULATIONS. | | | CALCULATE SQUARE FOOTAGE REQUIRED PER CODES REFERENCED | | | AND SHOW WHERE IT IS PROVIDED WITHIN THE PARKING AREA. | | | | | | 9. SATISFIED. SECTION 94-443(C)(3) REQUIRES THAT A | | | MINIMUM OF 75 PERCENT OF ALL TREES THAT ARE REQUIRED TO | | | BE PLANTED WITHIN THE INTERIOR OF AN OFF STREET PARKING | | | AREA SHALL BE CATEGORY 1 SHADE TREES. SHOW THE | | | PERCENTAGE OF CATEGORY 1 TREES PROVIDED FOR THE | | | REQUIRED LANDSCAPE AREAS. | | | | | | 10. PARTIALLY SATISFIED. PROVIDE CALCULATIONS FOR | | | REQUIRED BUFFER TREES AT ONE FOR EVERY 30 FEET OR | | | PORTION THEREOF FOR EACH BUFFER LENGTH, AND SHOW THE | | | NUMBER PROVIDED. | | | SEPARATE NORTH, SOUTH EAST AND WEST LENGTHS AND SHOW | | | REQUIRED AND PROVIDED TREES FOR EACH. | | | | | | 11. SATISFIED. THERE ARE TERMINAL LANDSCAPE ISLANDS | | | THAT DO NOT MEET THE 8 FEET LANDSCAPE AREA REQUIRED | | | INSIDE THE CURB. REVISE. | | | | | | | | | 12. SATISFIED. THERE APPEAR TO BE CONFLICTS IN SEVERAL | | | LOCATIONS BETWEEN TREES AND WATER AND SEWER LINES ON | | | THE LANDSCAPE PLAN. ADJUST LOCATIONS OF TREES OR | | | UTILITY LINES TO RESOLVE CONFLICTS WITH LANDSCAPING. | | | | | | 13. SATISFIED. SHOW COMPLIANCE WITH SECTION 94-445 L. | | | PLANT SPECIES. A MINIMUM OF 60 PERCENT OF PLANT | | | MATERIAL ADDED SHALL BE FLORIDA NATIVE OR DROUGHT | | | TOLERANT SPECIES SELECTED FROM THE CITY LIST OR THE | | | LIST OF SPECIES IN THE MOST RECENT EDITION OF SOUTH | | | FLORIDA WATER MANAGEMENT DISTRICT WATERWISE SOUTH | | | FLORIDA LANDSCAPES. PROVIDE THE ACTUAL PERCENTAGE BASED | | | ON THE PLANT LIST. | | | | | | ADDITIONAL COMMENTS 8/27/20: | | | 14. REMOVE SKY CLIMBER CULTIVAR AND INDICATE SPECIES | | | LIVE OAK. | | | | | | 15. SEPARATE TREES AND SHRUBS ON THE PLANT LIST | | | PROVIDED FOR THE NORTH PROPERTY. | | | | | | CONDITIONS OF APPROVAL | | | 1. PRIOR TO THE REMOVAL OR RELOCATION OF ANY TREES ON | | | THE PROPERTY, A TREE ALTERATION PERMIT SHALL BE | | | SUBMITTED, REVIEWED AND APPROVED BY THE DEVELOPMENT | | | SERVICES DEPARTMENT, PLANNING DIVISION. | | | |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
1 |
Status |
F |
Date |
07-06-2020 |
|
|
Cont ID |
|
| Sent By |
rcaranci |
Date |
07-06-2020 |
Time |
16:50 |
Rev Time |
0.00 |
| Received By |
rcaranci |
Date |
07-06-2020 |
Time |
16:50 |
Sent To |
|
|
| Notes |
| 2020-07-06 16:51:13 | FROM: RAY CARANCI, SENIOR LANDSCAPE PLANNER | | | 561-822-1462 | | | PROJECT: 1600 N AUSTRALIAN Z20060015 | | | JULY 6, 2020 | | | I HAVE REVIEWED THE ABOVE REFERENCED PETITION, AND | | | PROVIDE THE FOLLOWING COMMENTS: | | | | | | 1. MAKE THE FOLLOWING CORRECTIONS TO THE TREE | | | DISPOSITION PLAN SHEET 1 OF 1. | | | ? COLUMN FOR CONDITION MUST BE INCLUDED IN THE CHART. | | | ? GIVE THE CONDITION OF EACH TREE. | | | ? INCLUDE CANOPY DIAMETER MEASUREMENT FOR TREES IN | | | ORDER TO CALCULATE MITIGATION DUE IF REMOVED. | | | ? CANOPY SQUARE FOOTAGE FOR MITIGATION DUE FOR ANY | | | TREES PROPOSED FOR REMOVAL MUST BE IN A SEPARATE | | | COLUMN, AND THE TOTAL PROVIDED FOR THE COLUMN. | | | ? REMOVALS OF PALMS MUST INCLUDE THE MITIGATION | | | REQUIRED BY CATEGORY. | | | ? INCLUDE A CHART FOR TREE MITIGATION PROVIDED BASED ON | | | THE PLANT LIST AND PROVIDE THE TOTAL FOR THE SQUARE | | | FOOTAGE. | | | | | | 2. SECTION 94-448 (D)(3) REQUIRES NATIVE TREES IN GOOD | | | CONDITION TO BE PRESERVED ON SITE OR RELOCATED. ANSI A | | | 300 (PART 5) STANDARDS SPECIFY EXAMPLES OF SUITABILITY | | | RATINGS OF GOOD, MODERATE, OR POOR FOR RELOCATION. | | | PROVIDE CONDITION AND RELOCATION POTENTIAL FOR THE | | | NATIVE SABAL PALMS. | | | | | | 3. CITY POLICY REQUIRES THE USE OF FLORIDA NATIVE | | | SPECIES WHEN POSSIBLE. THERE ARE NATIVE ALTERNATIVES | | | FOR CARRISSA, PODOCARPUS, AND PITTOSPORUM. | | | | | | 4. CHECK THE FLORIDA FRIENDLY DESIGN OPTIONS LIST AND | | | SEE IF MORE POINTS CAN BE ADDED THROUGH NATIVE TREES | | | AND SHRUBS. THE ADDITIONAL SHADE TREES IN VEHICULAR USE | | | AREAS MUST BE VERIFIED IF CLAIMED. | | | | | | 5. ADJUST THE CALCULATIONS FOR MINIMUM SHADE TREE AND | | | FLOWERING TREE REQUIREMENTS PER SECTION 94-443(C)(2)B. | | | BASED ON REQUIRED OPEN SPACE OF 14793 SQ FT. SHADE | | | TREES-10, FLOWERING TREES -3, SHRUBS -30. FLOWERING | | | TREE CATEGORY IS MISSING. | | | | | | 6. ADD RELOCATED PALMS TO THE PLANT LIST AND COUNT THEM | | | TOWARD THE REQUIRED TREES. | | | | | | 7. MINIMUM TREE SIZES ARE 12 FEET, AND PALMS 8 FOOT | | | CLEAR TRUNK. MAKE CORRECTIONS. | | | | | | 8. PROVIDE A PLAN SHOWING THE PARKING LANDSCAPE AREAS | | | COUNTED TOWARD COMPLIANCE WITH SECTION 94-443(C)(3) AND | | | (4) AND PROVIDE CALCULATIONS. CALCULATE SQUARE FOOTAGE | | | REQUIRED PER CODES REFERENCED AND SHOW WHERE IT IS | | | PROVIDED WITHIN THE PARKING AREA. | | | | | | 9. SECTION 94-443(C)(3) REQUIRES THAT A MINIMUM OF 75 | | | PERCENT OF ALL TREES THAT ARE REQUIRED TO BE PLANTED | | | WITHIN THE INTERIOR OF AN OFF STREET PARKING AREA SHALL | | | BE CATEGORY 1 SHADE TREES. SHOW THE PERCENTAGE OF | | | CATEGORY 1 TREES PROVIDED FOR THE REQUIRED LANDSCAPE | | | AREAS. | | | | | | 10. PROVIDE CALCULATIONS FOR REQUIRED BUFFER TREES AT | | | ONE FOR EVERY 30 FEET OR PORTION THEREOF FOR EACH | | | BUFFER LENGTH, AND SHOW THE NUMBER PROVIDED. | | | | | | 11. THERE ARE TERMINAL LANDSCAPE ISLANDS THAT DO NOT | | | MEET THE 8 FEET LANDSCAPE AREA REQUIRED INSIDE THE | | | CURB. REVISE. | | | | | | | | | 12. THERE APPEAR TO BE CONFLICTS IN SEVERAL LOCATIONS | | | BETWEEN TREES AND WATER AND SEWER LINES ON THE | | | LANDSCAPE PLAN. ADJUST LOCATIONS OF TREES OR UTILITY | | | LINES TO RESOLVE CONFLICTS WITH LANDSCAPING. | | | | | | 13. SHOW COMPLIANCE WITH SECTION 94-445 L. PLANT | | | SPECIES. A MINIMUM OF 60 PERCENT OF PLANT MATERIAL | | | ADDED SHALL BE FLORIDA NATIVE OR DROUGHT TOLERANT | | | SPECIES SELECTED FROM THE CITY LIST OR THE LIST OF | | | SPECIES IN THE MOST RECENT EDITION OF SOUTH FLORIDA | | | WATER MANAGEMENT DISTRICT WATERWISE SOUTH FLORIDA | | | LANDSCAPES. PROVIDE THE ACTUAL PERCENTAGE BASED ON THE | | | PLANT LIST. | | | | | | CONDITIONS OF APPROVAL | | | 1. PRIOR TO THE REMOVAL OR RELOCATION OF ANY TREES ON | | | THE PROPERTY, A TREE ALTERATION PERMIT SHALL BE | | | SUBMITTED, REVIEWED AND APPROVED BY THE DEVELOPMENT | | | SERVICES DEPARTMENT, PLANNING DIVISION. | | | |
|
|
| Review Stop |
PARK |
PARKING |
| Rev No |
1 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
|
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
POLICE |
POLICE |
| Rev No |
1 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
|
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
PW |
PUBLIC WORKS |
| Rev No |
2 |
Status |
P |
Date |
08-27-2020 |
|
|
Cont ID |
|
| Sent By |
|
Date |
08-27-2020 |
Time |
|
Rev Time |
0.00 |
| Received By |
|
Date |
08-27-2020 |
Time |
|
Sent To |
|
|
| Notes |
| 2020-08-27 14:35:21 | NO FURTHER COMMNETS. | | | | | | MATT HEJAZI | | | DEPT. OF PUBLIC WORKS | | | [email protected] |
|
|
| Review Stop |
PW |
PUBLIC WORKS |
| Rev No |
1 |
Status |
F |
Date |
07-02-2020 |
|
|
Cont ID |
|
| Sent By |
|
Date |
07-02-2020 |
Time |
|
Rev Time |
|
| Received By |
|
Date |
07-02-2020 |
Time |
|
Sent To |
|
|
| Notes |
| 2020-07-02 14:52:50 | PLEASE PROVIDE AUTO TURN FOR THE SANITATION SERVICE, | | | FRONT LOADER TRUCK WITH THE FOLLOWING SPECS: | | | - TRUCK LENGTH: 35 FT | | | - TRUCK WIDTH: 11 FT | | | - TURNING RADIUS: | | | - SAE TURNING RADIUS: 32.5 FT | | | - CURB-TO-CURB DIAMETER: 74 FT | | | - WALL-TO-WALL DIAMETER: 86.3 FT | | | | | | FOR A FREESTANDING SITE DUMPSTER ENCLOSURE, THE | | | ENCLOSURE SHALL COMPLY WITH THE LATEST REVISION OF CITY | | | OF WEST PALM BEACH GENERAL CONSTRUCTION-GARBAGE | | | ENCLOSURE STANDARD, CG-7. | | | | | | MATT HEJAZI | | | PUBLIC WORKS | | | [email protected] | | | 561-822-2945 |
|
|
| Review Stop |
STORM |
STORMWATER |
| Rev No |
3 |
Status |
P |
Date |
11-02-2020 |
|
|
Cont ID |
|
| Sent By |
tward |
Date |
11-02-2020 |
Time |
22:49 |
Rev Time |
0.00 |
| Received By |
tward |
Date |
11-02-2020 |
Time |
22:52 |
Sent To |
|
|
| Notes |
| 2020-11-02 22:52:04 | THE FOLLOWING COMMENTS ARE FROM THE REVIEW OF THE | | | 10/14/2020 SUBMITTAL PACKAGE. THEY CAN BE ADDRESSED | | | DURING ENGINEERING PERMIT SUBMITTAL. | | | | | | 1. ADD VERTICAL DATUM REFERENCE AND CONVERSION EQUATION | | | TO NGVD1929 FOR THE TBM'S ON SHEET C-04. | | | | | | 2. CHANGE SPELLING OF CULVER CANAL TO CARVER CANAL ON | | | SHEET C-04. | | | | | | 3. SHEET C-14 SHOWS PROPOSED MINIMUM PERIMETER | | | ELEVATION OF 15.83 FEET NAVD1988. SECTION D-D ON THE | | | SAME SHEET SHOWS BERM TO BE BETWEEN 16.85 AND 17.51 | | | FEET NAVD AND GRADE AT PROPERTY LINE BETWEEN 17.1 AND | | | 17.5 FEET NAVD. WOULD A SWALE INSTEAD OF A BERM BE MORE | | | APPROPRIATE ALONG THE EAST PROPERTY LINE? | | | | | | 4. THE YARD DRAIN APPEAR TO BE CONNECTED TO THE ONSITE | | | DRAINAGE SYSTEM. WHY DO THEY NEED TO BE PERFORATED | | | BASINS AS INDICATED IN THE YARD DRAIN DETAIL ON SHEET | | | C-14? | | | | | | TRACY WARD, P.E. | | | SENIOR STORMWATER ENGINEER | | | ENGINEERING SERVICES DEPARTMENT | | | 561-494-1120 (O) | | | 561-351-0510 (M) | | | [email protected] | | | |
|
|
| Review Stop |
STORM |
STORMWATER |
| Rev No |
2 |
Status |
F |
Date |
09-18-2020 |
|
|
Cont ID |
|
| Sent By |
tward |
Date |
09-18-2020 |
Time |
14:24 |
Rev Time |
0.00 |
| Received By |
tward |
Date |
09-18-2020 |
Time |
15:04 |
Sent To |
|
|
| Notes |
| 2020-09-18 15:02:00 | THE FOLLOWING COMMENTS ARE FROM THE REVIEW OF THE | | | 8/19/2020 SUBMITTAL PACKAGE. | | | | | | 1. THE EXFILTRATION TRENCH DETAIL SHOWS THE TOP OF | | | TRENCH ELEVATION AS 13.50' NAVD. THE CONTROL STRUCTURE | | | DETAIL SHOWS THE WEIR ELEVATION AT 12.43' NAVD. THE | | | WEIR ELEVATION SHOULD BE SUCH TO COMPLETELY SURCHARGE | | | THE EXFILTRATION TRENCH. | | | | | | 2. THE CONTROL STRUCTURE DETAIL SHOWS A 2" WIDE X 26" | | | LONG BLEEDER AS PART OF THE WEIR STRUCTURE. NOTE THE | | | CITY DOES NOT ALLOW BLEEDERS WITH EXFILTRATION TRENCHES | | | UNLESS THERE IS A CONTROL STRUCTURE UPSTREAM OF THE | | | BLEEDER THAT WILL SURCHARGE THE EXFILTRATION TRENCH. | | | | | | 3. A NOTE ON SHEET C-07 CALLS OUT A 3" WEIR AT | | | ELEVATION 12.43 FEET. SHOULD THIS BE 3' INSTEAD OF 3"? | | | | | | 4. LIST THE VERTICAL DATUM AND CONVERSION EQUATION TO | | | NGVD1929 ON EVERY SHEET WITH ELEVATION INFORMATION. | | | | | | 5. SPECIFY RCP WHEN PROPOSED IN THE R/W. | | | | | | 6. FLOATING TURBIDITY BARRIERS MAY BE REQUIRED AT THE | | | END(S) OF THE 60" RCP. | | | | | | 7. SHOW STOP BAR AND STOP SIGN AT DRIVEWAY. | | | | | | 8. SHOW CROSSWALKS CROSSING DRIVE LANE AT THE HANDICAP | | | ACCESS AISLES. | | | | | | TRACY WARD, P.E. | | | SENIOR STORMWATER ENGINEER | | | ENGINEERING SERVICES DEPARTMENT | | | 561-494-1120 (O) | | | 561-351-0510 (M) | | | [email protected] | | | |
|
|
| Review Stop |
STORM |
STORMWATER |
| Rev No |
1 |
Status |
F |
Date |
07-09-2020 |
|
|
Cont ID |
|
| Sent By |
tward |
Date |
07-09-2020 |
Time |
10:13 |
Rev Time |
0.00 |
| Received By |
tward |
Date |
07-09-2020 |
Time |
10:16 |
Sent To |
|
|
| Notes |
| 2020-07-09 10:14:27 | THIS IS A CONCEPTUAL LEVEL REVIEW. CONSTRUCTION LEVEL | | | DETAILS, DESIGN CALCULATIONS AND THE POLLUTION | | | PREVENTION PLAN WILL BE REVIEWED AS PART OF THE | | | ENGINEERING DEVELOPMENT APPROVAL AND BUILDING PERMIT | | | APPLICATION PROCESSES. | | | | | | THE FOLLOWING COMMENTS MUST BE ADDRESSED PRIOR TO SITE | | | PLAN APPROVAL: | | | | | | 1. PROVIDE CONDITION ASSESSMENT OF EXISTING 60" RCP | | | THAT THE DRAINAGE SYSTEM WILL CONNECT TO. | | | | | | 2. THE CITY'S DRIVEWAY DETAIL IS FOR A CONCRETE APRON | | | WITHIN THE RIGHT OF WAY. | | | | | | 3. AUSTRALIAN AVENUE AND PALM BEACH LAKES BLVD. ARE | | | MAINTAINED BY PALM BEACH COUNTY. PERMITS MAY BE | | | REQUIRED FROM THE COUNTY FOR WORK WITHIN THE ROAD | | | RIGHT-OF-WAYS. | | | | | | 4. CONSIDER REDUCING THE PARKING STALL LENGTH BY | | | INCORPORATING A 2' LANDSCAPED OVERHANG. | | | | | | 5. LABEL THE PAVER AREA ON THE WEST SIDE OF THE | | | BUILDING ON THE ENGINEERING PLANS. | | | | | | 6. THE FIRE HYDRANT IS SHOWN CONNECTED TO THE BFO LINE | | | INSTEAD OF THE WATER MAIN ON AUSTRALIAN AVE. | | | | | | 7. SHOW THE PROPOSED FIRE HYDRANT AND UTILITY EASEMENT | | | ON THE LANDSCAPE PLAN. | | | | | | 8. WILL A PERIMETER BERM BE NEEDED FOR SECTIONS A-A AND | | | E-E? | | | | | | 9. DRAINAGE SYSTEM TO MEET SFWMD ERP CRITERIA. | | | | | | THE FOLLOWING COMMENTS MUST BE ADDRESSED PRIOR TO | | | ISSUANCE OF CONSTRUCTION AUTHORIZATION INCLUDING | | | BUILDING PERMITS AND ENGINEERING DEVELOPMENT APPROVAL. | | | | | | 1. AN ENGINEERING DEVELOPMENT APPROVAL APPLICATION MAY | | | BE REQUIRED FROM THE ENGINEERING SERVICES DEPARTMENT. | | | | | | 2. EROSION CONTROL PLAN AND DETAILS TO BE SUBMITTED | | | WITH THE ENGINEERING PERMIT APPLICATION. | | | | | | 3. PROVIDE A COPY OF THE SFWMD ERP AND DRAINAGE | | | CALCULATIONS PRIOR TO STARTING CONSTRUCTION. | | | | | | TRACY WARD, PE | | | SENIOR STORMWATER ENGINEER | | | ENGINEERING SERVICES DEPARTMENT | | | 561-494-1120 (O) | | | 561-351-0510 (M) | | | [email protected] | | | |
|
|
| Review Stop |
SURVEY |
SURVEYING |
| Rev No |
2 |
Status |
P |
Date |
09-11-2020 |
|
|
Cont ID |
|
| Sent By |
vnoel |
Date |
09-11-2020 |
Time |
13:48 |
Rev Time |
0.00 |
| Received By |
vnoel |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2020-09-11 13:49:46 | LAW DEPT. WORKING ON REVISED SHARED PARKING AGREEMENT. |
|
|
| Review Stop |
SURVEY |
SURVEYING |
| Rev No |
1 |
Status |
F |
Date |
07-07-2020 |
|
|
Cont ID |
|
| Sent By |
vnoel |
Date |
07-07-2020 |
Time |
09:14 |
Rev Time |
|
| Received By |
vnoel |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2020-07-07 09:48:04 | 1. SURVEY NEEDS TO BE SIGNED AND SEALED. | | | 2. PARKING AGREEMENT IN ORB 26131/545 NEEDS TO BE | | | SHOWN. WILL NEED TO BE MODIFIED. | | | 3. ADD CONVERSION TO NGVD ON SURVEY AND ENG. PLANS. | | | 4. SURVEY ALSO INCLUDES URBAN LEAGUE PROPERTY? | | | 5. EXISTING WATER AND SEWER SERVICES WILL NEED TO BE | | | VERIFIED. |
|
|
| Review Stop |
TRAFFIC |
TRAFFIC ENGINEERING |
| Rev No |
3 |
Status |
P |
Date |
11-06-2020 |
|
|
Cont ID |
|
| Sent By |
|
Date |
11-06-2020 |
Time |
|
Rev Time |
0.00 |
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2020-11-06 14:47:33 | PASSED WITH THE FOLLOWING CONDITIONS: | | | | | | 1) PROVIDE COUNTY TPS LETTER ONCE OBTAINED | | | 2) REVIEW BUDGET AND PROVIDE FEEDBACK AT NEXT/FINALL | | | SUBMISSION FOR POSSIBILITY OF EXPANDING THE SIDEWALK | | | ALONG AUSTRALIAN AVE. TO 10' | | | | | | VALERIO ORICCHIO | | | CITY TRANSPORTATION ENGINEER | | | 561-494-1092 | | | [email protected] |
|
|
| Review Stop |
TRAFFIC |
TRAFFIC ENGINEERING |
| Rev No |
2 |
Status |
F |
Date |
09-04-2020 |
|
|
Cont ID |
|
| Sent By |
|
Date |
09-04-2020 |
Time |
|
Rev Time |
0.00 |
| Received By |
|
Date |
08-19-2020 |
Time |
|
Sent To |
|
|
| Notes |
| 2020-09-04 15:04:02 | TRAFFIC COMMENTS | | | 1) PROVIDE COUNTY TPS LETTER ONCE THE TRAFFIC STUDY HAS | | | BEEN APPROVED | | | 2) REVIEW POSSIBILITY OF WIDER SIDEWALK ALONG | | | AUSTRALIAN AVENUE (FROM EXISTING5 FEET TO 8 FEET WIDE) | | | | | | VALERIO ORICCHIO | | | CITY TRANSPORTATION ENGINEER | | | 561-494-1092 | | | [email protected] | | | |
|
|
| Review Stop |
TRAFFIC |
TRAFFIC ENGINEERING |
| Rev No |
1 |
Status |
F |
Date |
07-09-2020 |
|
|
Cont ID |
|
| Sent By |
|
Date |
07-09-2020 |
Time |
|
Rev Time |
|
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2020-07-09 13:04:40 | | | | 1. PROVIDE COUNTY TPS LETTER | | | 2. IDENTIFY THE LOADING ZONE | | | 3. PROVIDE AUTOTURN ANALYSIS FOR VEHICLES PARKING IN | | | AND OUT OF THE LAST STALLS ON THE WEST SIDE LOTS | | | 4. PROVIDE WIDER SIDEWALK ALONG AUSTRALIAN AVENUE | | | (MINIMUM 8?) | | | 5. IF THE NE HANDICAP PARKING STALL IS INTENDED FOR THE | | | EXISTING URBAN LEAGUE BUILDING, THAT SITE NEEDS TO BE | | | INCLUDED IN THE PLANS | | | | | | | | | VALERIO ORICCHIO | | | CITY TRANSPORTATION ENGINEER | | | 561-494-1092 | | | [email protected] | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
11-10-2020 |
|
|
Cont ID |
|
| Sent By |
|
Date |
11-10-2020 |
Time |
|
Rev Time |
0.00 |
| Received By |
|
Date |
11-10-2020 |
Time |
|
Sent To |
|
|
| Notes |
| 2020-11-10 16:21:21 | HCD INFORMAL SITE PLAN REVIEW 1600 N AUSTRALIAN AVENUE | | | - PROJECT #Z20060015 | | | PROCESS COMMENTS: | | | | | | -PLEASE NOTE THAT YOU WILL BE ACCESSED A RESUBMITTAL | | | FEE OF 20% OF THE ORIGINAL APPLICATION FEE. | | | | | | ******************************************************* | | | *********** | | | | | | - PROVIDE INFORMATION ON SHARED PARKING AGREEMENT. | | | INFORMATION TO BE PROVIDED PRIOR TO CO. | | | | | | | | | ALANA WOOTEN | | | PLANNER | | | PLANNING DIVISION | | | 561-822-1449 | | | [email protected] | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
09-17-2020 |
|
|
Cont ID |
|
| Sent By |
|
Date |
09-17-2020 |
Time |
|
Rev Time |
0.00 |
| Received By |
|
Date |
09-17-2020 |
Time |
|
Sent To |
|
|
| Notes |
| 2020-09-21 09:47:11 | HCD INFORMAL SITE PLAN REVIEW ? 1600 N AUSTRALIAN | | | AVENUE - PROJECT #Z20060015 | | | | | | PROCESS COMMENTS: | | | | | | -PLEASE PROVIDE RESPONSES TO ALL REVIEW COMMENTS IN | | | WRITTEN FORMAT. | | | -PLEASE NOTE THAT YOU WILL BE ACCESSED A RESUBMITTAL | | | FEE ON SUBSEQUENT SUBMITTALS. SUCH FEE WILL BE 20% OF | | | THE ORIGINAL APPLICATION FEE. | | | | | | ******************************************************* | | | *********** | | | | | | - PROVIDE TRAFFIC CONCURRENCY LETTER. SATISFIED | | | | | | - PROVIDE UTILITY LETTERS. SATISFIED | | | | | | - PROVIDE THE STANDARDS FOR CODE COMPLIANCE. SATISFIED | | | | | | - PROVIDE SIGNED AND SEALED PLANS (DIGITAL). | | | ACKNOWLEDGED FOR NEXT SUBMITTAL | | | | | | - CONSIDER MORE BICYCLE PARKING FOR THE VISITORS/GUESTS | | | OF THE VICKERS HOUSE. SATISFIED | | | | | | - CONSIDER PROVIDING A SHOWER FACILITY. SATISFIED | | | | | | - ADD THE BICYCLE PARKING TO THE INFORMATION TABLE. | | | SATISFIED | | | | | | - CONSIDER RE-DESIGNING THE PARKING AREA AROUND THE | | | ENTRANCE WITH THE DEAD-END PARKING ON BOTH SIDES. A | | | POSSIBLE SOLUTION MAYBE TO DESIGNATE A PARKING SPACE | | | FOR TURN AROUND. SATISFIED | | | | | | - PROVIDE INFORMATION ON SHARED PARKING AGREEMENT. NOT | | | SATISFIED | | | | | | - PROVIDE A LOADING SPACE BY CODE. (10? X 25?). | | | SATISFIED | | | | | | - SEE THE CITY?S TYPICAL DUMPSTER ENCLOSURE DETAIL. | | | SATISFIED. | | | | | | - SIGNAGE WILL REQUIRE A SEPARATE PERMIT. ACKNOWLEDGED. | | | | | | ALANA WOOTEN | | | PLANNER | | | PLANNING DIVISION | | | 561-822-1449 | | | [email protected] | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
07-07-2020 |
|
|
Cont ID |
|
| Sent By |
|
Date |
07-07-2020 |
Time |
|
Rev Time |
|
| Received By |
|
Date |
07-07-2020 |
Time |
|
Sent To |
|
|
| Notes |
| 2020-07-07 13:33:55 | PPRC ZONING REVIEW - HCD COMMUNITY RESOURCE CENTER - | | | 1600 N. AUSTRALIAN AVENUE | | | | | | - PROVIDE TRAFFIC CONCURRENCY LETTER | | | | | | - PROVIDE UTILITY LETTERS. | | | | | | - PROVIDE THE STANDARDS FOR CODE COMPLIANCE. | | | | | | - PROVIDE SIGNED AND SEALED PLANS. | | | | | | - CONSIDER MORE BICYCLE PARKING FOR THE VISITORS/GUESTS | | | OF THE VICKERS HOUSE. | | | | | | - CONSIDER PROVIDING A SHOWER FACILITY. | | | | | | - ADD THE BICYCLE PARKING TO THE INFORMATION TABLE. | | | | | | - CONSIDER RE-DESIGNING THE PARKING AREA AROUND THE | | | ENTRANCE WITH THE DEAD-END PARKING ON BOTH SIDES. A | | | POSSIBLE SOLUTION MAYBE TO DESIGNATE A PARKING SPACE | | | FOR TURN AROUND. | | | | | | - PROVIDE INFORMATION ON SHARED PARKING AGREEMENT. | | | | | | - PROVIDE A LOADING SPACE BY CODE. (10? X 25?). | | | | | | - SEE THE CITY?S TYPICAL DUMPSTER ENCLOSURE DETAIL. | | | | | | - SIGNAGE WILL REQUIRE A SEPARATE PERMIT. | | | | | | ALANA WOOTEN | | | PLANNER | | | PLANNING DIVISION | | | 561-822-1449 | | | [email protected] | | | |
|
|
| |
Print |
|