Plan Review Details - Project Z20040025
Plan Review Stops For Project Z20040025
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 05-18-2020 Cont ID  
Sent By rbrown Date 05-18-2020 Time 18:00 Rev Time 0.00
Received By rbrown Date 05-18-2020 Time 18:00 Sent To  
Notes
2020-05-18 18:02:373 FOOT SETBACK FROM WEST PROPERTY LINE FOR WEST
 ELEVATION OF LEWIS HALL WEST BUILDING IS NOTED. NO
 FURTHER COMMENTS ON PROPOSED REPLAT.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 05-18-2020 Cont ID  
Sent By rbrown Date 05-18-2020 Time 14:31 Rev Time 0.00
Received By rbrown Date 05-18-2020 Time 14:31 Sent To  
Notes
2020-05-18 14:31:28DEVELOPMENT SERVICES DEPARTMENT, BUILDING DIVISION,
 COMMENTS:
  
 1. THIS REVIEW IS A CURSORY REVIEW AS IT RELATES TO THE
 SITE. IT IS NOT A REVIEW FOR FULL COMPLIANCE WITH
 FLORIDA BUILDING CODE.
  
 2. THE WEST ELEVATION OF THE LEWIS HALL WEST BUILDING
 HAS WINDOW OPENINGS, LOUVERS AND WALL-MOUNTED AIR
 CONDITIONING UNITS. THOSE ARE CONSIDERED AS UNPROTECTED
 OPENINGS AND, PER SECTION 705.8.1 OF FLORIDA BUILDING
 CODE, THE EXTERIOR WALL MUST BE AT LEAST 3 FEET FROM
 THE PROPERTY LINE, AND THE AREA OF THOSE OPENINGS IN
 ANY STORY MUST BE NO MORE THAN 15% OF THE WALL AREA OF
 THAT STORY. COMPLIANCE CANNOT BE ASSESSED BECAUSE NO
 DIMENSIONED SITE PLAN HAS BEEN PROVIDED TO SHOW THAT
 THE WEST ELEVATION OF THE LEWIS HALL WEST BUILDING WILL
 BE AT LEAST 3 FEET FROM THE PROPERTY LINE, AND NO
 CALCULATIONS HAVE BEEN PROVIDED TO SHOW THAT THE AREA
 OF THE OPENINGS IN THE FIRST AND SECOND STORIES OF THE
 WALL IS LESS THAN 15% OF THE WALL AREA OF THAT STORY.
  
 ROBERT BROWN
 BUILDING OFFICIAL
 TEL: 561 805 6652
 EMAIL: [email protected]
  

Review Stop SURVEY SURVEYING
Rev No 1 Status F Date 05-19-2020 Cont ID  
Sent By vnoel Date 05-19-2020 Time 13:10 Rev Time 0.00
Received By vnoel Date   Time   Sent To  
Notes
2020-05-19 13:11:13A SEPARATE COMMENTS LETTER WILL BE ISSUED BY WEDNESDAY
 5/20.

Review Stop Z ZONING
Rev No 1 Status F Date 05-19-2020 Cont ID  
Sent By elevesqu Date 05-19-2020 Time 14:07 Rev Time 0.00
Received By elevesqu Date 05-18-2020 Time 13:32 Sent To  
Notes
2020-05-19 14:07:491. INCLUDE LOT EAST OF FLAGLER IN PLAT
 2. MISSING DAY AND MONTH LINES FOR THE ?IN WITNESS
 WHEREOF? LINE TO BE SIGNED BY MARY MARGARET PACHUCKI
 3. NEED SIDEWALK EASEMENT FOR PORTION OF SIDEWALK
 WITHIN PRIVATE PROPERTY ALONG FLAGLER DRIVE ON BOTH
 EAST AND WEST SIDES
  
 LIZ LEVESQUE, URBAN DESIGN PLANNER
 561 822 1426
 [email protected]