Plan Review Details - Project Z20030005
Plan Review Stops For Project Z20030005
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 10-08-2020 Cont ID  
Sent By rbrown Date 10-08-2020 Time 14:11 Rev Time 0.00
Received By rbrown Date 10-08-2020 Time 14:11 Sent To  
Notes
2020-10-08 14:12:33REVIEWED AND PASSED UNDER Z19050019. THE PROPOSED
 CHANGES DO NOT NEGATIVELY IMPACT THE PREVIOUS PASSED
 REVIEW.
  
  
 ROBERT BROWN
 BUILDING OFFICIAL
 TEL: 561 805 6652
 EMAIL: [email protected]
  
2020-03-09 15:49:45 
  
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 09-23-2020 Cont ID  
Sent By pleduc Date 09-23-2020 Time 11:05 Rev Time 0.00
Received By pleduc Date 09-23-2020 Time 11:05 Sent To  
Notes
2020-09-23 11:05:57FIRE HAS NO OBJECTIONS TO THE PROPOSED CHANGES AND
 APPROVES, HOWEVER, THE BUREAU'S APPROVAL OF THIS
 SUBMITTED PROJECT DOES NOT CONSTITUTE ITS FINAL REVIEW
 OR APPROVAL.
  
 THE BUREAU SHALL REVIEW ALL SUBMITTED BUILDING PLANS AT
 THE APPROPRIATE TIME AND IN ACCORDANCE WITH THE
 REQUIREMENTS OF ALL APPLICABLE CODES AND STANDARDS.
  
 PETER LEDUC
 FIRE MARSHAL
 WEST PALM BEACH FIRE DEPARTMENT
 561-804-4709
 [email protected]
  

Review Stop L LANDSCAPING
Rev No 2 Status P Date 12-29-2020 Cont ID  
Sent By rcaranci Date 12-29-2020 Time 12:37 Rev Time 0.00
Received By rcaranci Date 12-29-2020 Time 12:37 Sent To  
Notes
2020-12-29 12:37:47FROM: RAY CARANCI, LANDSCAPE PLANNER 561-822-1462
 PROJECT: 575 ROSEMARY (MACY?S) MINOR AMENDMENT
 Z20030005
 DECEMBER 29, 2020
 I HAVE REVIEWED THE ABOVE REFERENCED PETITION, AND
 PROVIDE THE FOLLOWING COMMENTS:
  
 1. SATISFIED. SHOW THE LANDSCAPING FOR THE STREETSCAPE
 SECTIONS ON THE LANDSCAPE PLAN AS SHOWN ON THE APPROVED
 PLANS DATED 10/25/19.
  
 2. SATISFIED. PUBLIC OPEN SPACE ?A? PLAZA AREA AT
 GROUND LEVEL CANNOT HAVE THE THIN STRIP ALONG THE
 BUILDING COUNTED AS IT DOES NOT MEET THE NO ONE SIDE
 FIVE TIMES ANY OTHER SIDE REQUIREMENT. PLAZA INTENT IS
 TO HAVE CONSOLIDATED USEABLE AREA AS PREVIOUSLY
 APPROVED.
  
 3. SATISFIED. ROOFTOP GARDEN ON LEVEL 3 NEEDS TO SHOW
 ALL AREAS WITHIN THE PERIMETER AS PRIVATE OPEN SPACE,
 ONLY EXCEPTING THE SOLID COVERED AREAS, THEN SHOW
 REQUIREMENTS FOR VEGETATED AREA.
  
  

Review Stop L LANDSCAPING
Rev No 1 Status F Date 10-16-2020 Cont ID  
Sent By rcaranci Date 10-16-2020 Time 15:01 Rev Time 0.00
Received By rcaranci Date 10-16-2020 Time 10:25 Sent To  
Notes
2020-10-16 15:02:00FROM: RAY CARANCI, LANDSCAPE PLANNER 561-822-1462
 PROJECT: 575 ROSEMARY (MACY?S) MINOR AMENDMENT
 Z20030005
 OCTOBER 16, 2020
 I HAVE REVIEWED THE ABOVE REFERENCED PETITION, AND
 PROVIDE THE FOLLOWING COMMENTS:
  
 1. SHOW THE LANDSCAPING FOR THE STREETSCAPE SECTIONS ON
 THE LANDSCAPE PLAN AS SHOWN ON THE APPROVED PLANS DATED
 10/25/19.
  
 2. PUBLIC OPEN SPACE ?A? PLAZA AREA AT GROUND LEVEL
 CANNOT HAVE THE THIN STRIP ALONG THE BUILDING COUNTED
 AS IT DOES NOT MEET THE NO ONE SIDE FIVE TIMES ANY
 OTHER SIDE REQUIREMENT. PLAZA INTENT IS TO HAVE
 CONSOLIDATED USEABLE AREA AS PREVIOUSLY APPROVED.
  
 3. ROOFTOP GARDEN ON LEVEL 3 NEEDS TO SHOW ALL AREAS
 WITHIN THE PERIMETER AS PRIVATE OPEN SPACE, ONLY
 EXCEPTING THE SOLID COVERED AREAS, THEN SHOW
 REQUIREMENTS FOR VEGETATED AREA.
  

Review Stop Z ZONING
Rev No 4 Status P Date 02-25-2021 Cont ID  
Sent By eschneid Date 02-25-2021 Time 11:30 Rev Time 1.00
Received By eschneid Date 02-25-2021 Time 10:02 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 3 Status F Date 01-12-2021 Cont ID  
Sent By eschneid Date 01-12-2021 Time 09:10 Rev Time 4.00
Received By eschneid Date 12-30-2020 Time 14:16 Sent To  
Notes
2021-01-12 09:11:23CASE NO. PB 950XXXXX - RESUBMITTAL
 575 S. ROSEMARY REDEVELOPMENT
 575 S. ROSEMARY
  
 - CONTACT ERIC SCHNEIDER @ (561) 822-1446,
 [email protected]
  
 - PLEASE PROVIDE RESPONSES TO REVIEW COMMENTS IN
 WRITTEN FORMAT.
  
 - WHEN RESUBMITTING, PLEASE PROVIDE A MINIMUM OF TWO
 (2) PAPER COPIES AND AN ELECTRONIC COPY IN .PDF FORMAT
 OF ALL PLANS.
  
 1) THE UPDATED TABLE ON SHEET A0.09.1 LISTS THE GROUND
 FLOOR AS HAVING 26,054 SQUARE FEET; HOWEVER, WHEN
 ADDING UP THE VARIOUS AREAS, THE TOTAL IS 26, 266
 SQUARE FEET. IT APPEARS THAT THE SHOP SQUARE FOOTAGE
 MAY HAVE BEEN LEFT OUT OF THE TABLE. THE TOTAL SQUARE
 FOOTAGE VALUE ON THE TABLE AND ON SHEET A0.01 PARKING
 REQUIRED NEED TO BE CORRECTED (AS WELL AS ANY OTHER
 TABLE). NOTE: PARKING REQUIREMENT DOES NOT CHANGE.
  
 2) THANK YOU FOR PROVIDING UPDATED ELEVATION DRAWINGS
 SHOWING THE ROOFTOP FEATURES. IN ORDER TO COMPLY WITH
 THE CITYPLACE DRI, SCREENING REQUIREMENTS, YOU NEED TO
 HAVE EITHER THE PARAPET OR OTHER METHOD OF SCREENING
 INSTALLED TO THE HEIGHT OF THE ROOFTOP EQUIPMENT IN
 ORDER TO SCREEN IT FROM PUBLIC VIEW. BASED ON THE
 HEIGHT OF THE BUILDING, THE PUBLIC VIEW ENCOMPASSES
 MORE THAN THE PERSON STANDING AT STREET LEVEL AT THE
 BASE OF THE BUILDING. THE SCREENING TO THE HEIGHT OF
 THE MECHANICAL EQUIPMENT IS THE STANDARD FOR ROOFTOP
 EQUIPMENT ON TOWER IN THE DMP. THE BUILDINGS WITHIN THE
 DRI ARE TO BE CONSISTENT WITH BUILDINGS SURROUNDING THE
 DRI.
  
 3) SHEET A0.10 DRAWING 1 LISTS FLOORS 5-21. THIS NEEDS
 TO BE CORRECTED TO FLOORS 5-20 SINCE THE PH IS LEVEL 21
 AND IS SHOWN ON DRAWING 2.
  
 4) THE SPECIFICS OF THE REQUIRED VEHICLE CHARGER
 INSTALLATION WILL BE REVIEWED DURING THE BUILDING
 PERMIT REVIEW FOR THEIR INSTALLATION IN THE GARAGE.
 PLEASE NOTE THAT THE CITY'S BUILDING OFFICIAL HAS
 DETERMINED THAT AN ACCESSIBLE VEHICLE CHARGING SPACE
 NEEDS TO BE PROVIDED AT A RATIO OF 1:25 PER VEHICLE
 CHARGING SPACES PROVIDED. THIS WILL IMPACT NOT ONLY THE
 PLANS AS SHOWN WITH THIS APPLICATION, BUT ALSO THE
 PROPOSED CHARGING STATIONS IN OTHER GARAGES. THE
 SPECIFICS WILL NEED TO BE DISCUSSED WITH THE BUILDING
 DIVISION AS THIS PROCESS MOVES FORWARD. THE CORRECTION
 MAY BE TO MOVE ONE OF THE CHARGING STATIONS BETWEEN AN
 ADA SPACE AND A REGULAR SPACE.
  
 5) THE PARKING GARAGE IS REQUIRED TO PROVIDE A MINIMUM
 OF 10 ELECTRIC VEHICLE CHARGING STATIONS OR ELECTRIC
 CHARGING STATIONS EQUAL TO TWO (2) PERCENT OF THE TOTAL
 PARKING SPACES REQUIRED FOR THE NEW BUILDING BUILT
 WITHIN THE ROSEMARY SQUARE CENTER SUBAREA, WHICHEVER IS
 LESS, IN THE D BLOCK PARKING GARAGE. WHILE THERE ARE 10
 PARKING SPACES ADJACENT TO THE PROPOSED CHARGING
 STATIONS, THE PLANS TO NOT CLEARLY INDICATE THE ABILITY
 TO CHARGE 10 CARS AT ONE TIME. WHILE THIS DOES NOT NEED
 TO BE SHOWN NOW, IT WILL NEED TO BE INCLUDED AT THE
 TIME OF PERMITTING FOR THE GARAGE UPGRADES.
  
 6) PLEASE REMEMBER THAT ANY TENANT SPACE HAVING MORE
 THAN 10,000 SQUARE FEET OF FLOOR AREA MUST PROVIDE A
 SHOWER AND CHANGING ROOM. WHILE THIS WILL BE VERIFIED
 DURING THE TENANT BUILD OUT, PLEASE ENSURE THAT THE
 OVERALL BUILDING LAYOUT IS NOT DESIGNED IN SUCH A WAY
 TO HINDER THE TENANT BUILD OUT.
  
 7) THE ROSEMARY SQUARE CENTER SUBAREA REQUIRE THE
 FOLLOWING WHICH NEEDS TO BE CLEARLY INDICATED IN THE
 PERMIT DRAWINGS:
  
 A. THE BUILDING ROOF IS TO EITHER HAVE SOLAR
 INSTALLATIONS OR UTILIZE A GREEN ROOF INSTALLATION
 (ACTIVE OR PASSIVE); EXCLUSIVE OF AREAS REQUIRED FOR
 MECHANICAL EQUIPMENT.
  
 B. THE ROOFTOP RAINWATER IS TO BE CAPTURED AND RETAINED
 ONSITE. THE USE OF THE CAPTURED RAINWATER FOR
 IRRIGATION AND OTHER NON-POTABLE USES IS ENCOURAGED;
 HOWEVER, AT A MINIMUM, ONSITE GROUNDWATER INFILTRATION
 IS REQUIRED.
  
 C. THE WORKFORCE UNITS MUST BE DISTRIBUTED THROUGHOUT
 THE BUILDING WITH NO MORE THAN 50% OF THE UNITS ON ANY
 ONE FLOOR BEING WORKFORCE SET ASIDE UNITS. WORKFORCE
 UNITS WILL ALSO NOT BE GROUPED INTO ANY ONE UNIT SIZE
 (E.G. - STUDIOS, 1 BEDROOM) ON A GIVEN FLOOR. THE
 VARIETY OF UNIT BEDROOM SIZES WILL BE MAXIMIZED TO THE
 GREATEST EXTENT THAT IS FEASIBLE.
  

Review Stop Z ZONING
Rev No 2 Status F Date 10-22-2020 Cont ID  
Sent By eschneid Date 10-22-2020 Time 11:36 Rev Time 8.00
Received By eschneid Date 10-15-2020 Time 09:24 Sent To  
Notes
2020-10-22 11:37:18CASE NO. PB 950XXXXX
 575 S. ROSEMARY REDEVELOPMENT
 575 S. ROSEMARY
  
 - CONTACT ERIC SCHNEIDER @ (561) 822-1446,
 [email protected]
  
 - PLEASE PROVIDE RESPONSES TO REVIEW COMMENTS IN
 WRITTEN FORMAT.
  
 - WHEN RESUBMITTING, PLEASE PROVIDE A MINIMUM OF TWO
 (2) PAPER COPIES AND AN ELECTRONIC COPY IN .PDF FORMAT
 OF ALL PLANS.
  
 1) THE DOCK MANAGER OFFICE AND SHOP (335 SF) NEED TO BE
 INCLUDED IN THE RETAIL NET SF FOR THE PARKING
 CALCULATIONS. NOTE: PARKING REQUIREMENT DOES NOT
 CHANGE.
  
 2) WHAT IS HAPPENING IN THE AREA ON LEVEL 4 THAT IS
 ADJACENT TO THE BAR? IT IS LISTED AS 538 GROSS SQ. FT.,
 BUT NOT HIGHLIGHTED ON SHEET A0.09.
  
 3) PASSAGEWAY:
  
 A. THE NOTE REQUIRING THE PUBLIC SPACE EASEMENT AT THE
 WESTERN TERMINUS OF THE PASSAGEWAY NEEDS TO BE ADDED ON
 DRAWING 1 ON SHEET A0.05. THIS IS REQUIRED BY THE
 DEVELOPMENT REGULATIONS IN RESOLUTION NO. 362-19.
  
 B. THE PASSAGEWAY IS PUBLIC OPEN SPACE; THEREFORE,
 DIRECT ACCESS IS REQUIRED FROM THE NORTH SIDE OF THE
 BUILDING TO THE PASSAGEWAY.
  
 4) PUBLIC OPEN SPACE - PLAZA
  
 A. NO ONE SIDE OF A PLAZA MAY BE 5X THE LENGTH OF
 ANOTHER SIDE. THE HIBISCUS ROW FRONTAGE IS SLIGHTLY
 LESS THAN 9 FEET WHILE THE ROSEMARY ROW FRONTAGE IS
 OVER 109 FEET, WHICH IS 11X LONGER. THIS AREA NEEDS TO
 BE EXCLUDED FROM THE PLAZA AND BECOME A COURTYARD AGAIN
 TO CORRECT THIS.
  
 4) PRIVATE OPEN SPACE - POOL DECK
  
 A. PLEASE VERIFY THAT THE BAR AREA WILL HAVE A SOLID
 ROOF. IF SO, PROVIDE INFORMATION AS TO WHAT THE
 CONSTRUCTION MATERIALS WILL BE.
  
 B. THE OPEN SPACE AREA NEEDS TO ENCOMPASS THE ENTIRE
 CONTIGUOUS 4TH FLOOR AMENITY AREA. YOU MAY NOT
 SELECTIVELY EXCLUDE PORTIONS IN ORDER TO REDUCE THE
 TOTAL AREA TO MEET THE LANDSCAPE MINIMUM.
  
 5) ACTIVE USE
  
 A. THE GROUND LEVEL OF THE HIBISCUS FRONTAGE SHOWS THE
 WESTERN 16 FOOT SECTION AS PART OF THE PROVIDED ACTIVE
 USE. THIS AREA MAY NOT BE INCLUDED SINCE IT DOES NOT
 HAVE THE REQUIRED 25 FOOT DEPTH.
  
 B. ON LEVEL 3, THERE IS A SECTION OF THE MAINTENANCE
 OFFICE THAT NEEDS TO SHOW THAT IT IS A MINIMUM OF 15
 FEET IN DEPTH. IT DOES NOT SCALE AS COMPLYING.
  
 C. THE ACTIVE USE LINER TABLE ON SHEET A0.01 LISTS AN
 INCORRECT DIMENSION FOR THE 3RD LEVEL ALONG HIBISCUS
 STREET. IT IS NOT 182.75 FEET.
  
 6) THE PARKING GARAGE DRAWINGS SHOW THE GARAGE ENTRANCE
 AT THE NORTHEAST CORNER OF THE GARAGE AT THE LOCATION
 WHERE IT CROSSES THE CITYPLACE TOWNHOUSE POA PROPERTY.
 PROVIDE RECORDED DOCUMENTATION FROM THE POA THAT YOU
 ARE PERMITTED TO USE THEIR PROPERTY TO ACCESS THE
 GARAGE OR THIS MAY NOT CHANGE FROM THE LAYOUT APPROVED
 AS PART OF RESOLUTION NO. 362-19. THE PARKING NUMBERS
 NEED TO REFLECT THE FINAL CONFIGURATION.
  
 7) RESIDENTIAL BICYCLE PARKING
  
 A. THE BICYCLE PARKING CALCULATIONS ROUND UP, SO THE
 362 UNITS REQUIRE 37, NOT 36 PARKING SPACES. YOU ARE
 PROVIDING 38 SPACES, SO THIS JUST NEEDS TO BE UPDATED
 ON THE RESIDENTIAL TABLE.
  
 B. THE RESIDENTIAL BICYCLE ROOM SHOWS THREE SPACES THAT
 DO NOT FUNCTION DUE TO THE PROXIMITY TO THE WALL AND
 THE ACCESS PATH. THESE THREE SPACES EXCEED THE 38
 PARKING SPACES THAT ARE PROVIDED AND NEED TO BE
 REMOVED.
  
 8) SHEET A0.01.1 EAST ELEVATION DIAGRAM INCLUDES LABELS
 FOR AREAS E AND F. THESE TWO AREAS DO NOT APPEAR IN THE
 SAME LOCATION/CONFIGURATION ON THE EAST ELEVATION.
 PLEASE CLARIFY.
  
 9) THE ELEVATION MEASURE TO THE TOP OF THE HIGH ROOF ON
 THE ELEVATION DRAWINGS DOES NOT MATCH THE ELEVATION TAG
 ON THE HIGH ROOF PLAN (SHEET A1.07).
  
 10) THE SOUTH ELEVATION DRAWINGS SHOW THAT THE UNITS ON
 THE 5TH LEVEL HAVE BALCONY SLIDER DOORS OVERLOOKING THE
 PODIUM ROOF. THIS GLAZING MAY NOT OPEN TO ACCESS THE
 ROOF, SINCE THE ROOF IS NOT PERMITTED TO HAVE RAILING
 AS IT WOULD EXCEED THE PODIUM HEIGHT. PLEASE CORRECT SO
 THAT THE ACCURATE CONDITIONS ARE SHOWN.
  
 11) PLEASE REMEMBER THAT THE CITYPLACE DRI, REQUIRES
 THAT ALL ROOFTOP MECHANICAL EQUIPMENT BE SCREENED FROM
 PUBLIC VIEW. YOU NEED TO PROVIDE VERIFICATION THAT THIS
 REQUIREMENT IS MET.
  
 A. PROVIDE THE ANTICIPATED HEIGHT OF THE RESIDENTIAL
 CONDENSING UNITS (WITH CURB) AND THE HEIGHT OF THE
 PARAPET WALL AROUND THE CONDENSING UNITS. THIS
 DIMENSION TAG NEEDS TO BE ON BOTH THE ROOF PLAN AND THE
 ELEVATION DRAWINGS.
  
 B. THE ELEVATION DRAWINGS NEED TO SHOW ALL THE ROOFTOP
 FEATURES. THERE ARE MESH LOOKING FEATURES ON EITHER END
 OF THE MAIN ROOF PLAN WHICH DO NOT SHOW ON THE
 ELEVATIONS AND NEED TO BE EXPLAINED AND LABELED.
 ADDITIONALLY, THERE ARE TWO OTHER ROOFTOP FEATURES THAT
 ARE NOT LABELED OR SHOWN ON THE ELEVATIONS (LOOK LIKE
 GENERATORS ON THE PLAN), WHICH NEED TO BE EXPLAINED.
  

Review Stop Z ZONING
Rev No 1 Status F Date 03-09-2020 Cont ID  
Sent By eschneid Date 03-09-2020 Time 15:49 Rev Time 1.50
Received By eschneid Date 03-09-2020 Time 15:04 Sent To  
Notes
2020-03-09 15:50:47CASE NO. PB 950XXXXX
 575 S. ROSEMARY REDEVELOPMENT
 575 S. ROSEMARY
  
 - CONTACT ERIC SCHNEIDER @ (561) 822-1446,
 [email protected]
  
 - PLEASE PROVIDE RESPONSES TO REVIEW COMMENTS IN
 WRITTEN FORMAT.
  
 - WHEN RESUBMITTING, PLEASE PROVIDE A MINIMUM OF FOUR
 (4) PAPER COPIES AND AN ELECTRONIC COPY IN .PDF FORMAT
 OF ALL PLANS.
  
 1) ZONING STAFF HAS REVIEWED THE INFORMATION SUBMITTED
 AS PART OF THIS APPLICATION AN NOTED THAT IT DOES NOT
 INCLUDE ALL OF THE INFORMATION THAT STAFF NEEDS FOR THE
 REVIEW AND AMENDED PLANS THAT WERE APPROVED AS PART OF
 RESOLUTION NO. 362-19.
  
 2) THE FOLLOWING PLAN SHEETS SHOWING THE PROPOSED
 BUILDING DESIGN ARE REQUIRED:
  
 SHEET A0.01 - SITE/PROJECT DATA
 SHEETS A0.01.1 AND A0.01.2 - FACADE CALCULATIONS
 SHEET A0.04.2 - SITE PLAN
 SHEET A0.05 - OPEN SPACE DIAGRAMS
 SHEET A0.06 - ACTIVE USE DIAGRAMS
 SHEETS A0.07, A0.08, A0.09, A0.09.1 AND A0.10 - VARIOUS
 SF VERIFICATION DIAGRAMS
 SHEETS A1.01, A1.02, A1.03, A1.04, A1.04A, A1.05,
 A1.06, A1.07 AND A1.09 - FLOOR PLAN DIAGRAMS
 SHEETS A2.00.2, A2.01.2, A2.02.2 AND A2.03.2 -
 ELEVATIONS
 SHEETS LH-01 AND LH-02 - HARDSCAPE PLANS
 SHEETS LP-01, LP-02, LP-03, LP-04, LP-05 AND LP-06
  
 3) ALL CODE REQUIRED DATA NEEDS TO BE UPDATED - ACTIVE
 USE, PARKING COUNTS, PUBLIC/PRIVATE OPEN SPACE, ETC.
  
 4) THE UNIT B1.4 BALCONY APPEARS TO ENCROACH ON THE
 ACCESS EASEMENT SETBACK (SHEET A1.09).
  
 5) UPDATED OVERALL ROSEMARY SQUARE PARKING AVAILABILITY
 TABLE REFLECTING THE NEW, REDUCED PARKING REQUIREMENT.
 THIS CAN ALSO INCLUDE THE NEW SPACES DEDICATED TO THE
 CAR DEALER IN B GARAGE.
  
 6) THERE IS A DISCREPANCY IN THE AMOUNT OF CHANGE
 BETWEEN THE EXISTING AND PROPOSED BUILDING SQUARE
 FOOTAGE. THE FOOTPRINT COMPARISON DONE BY LEO DALY
 SHOWS 3,195 LESS SQUARE FEET IN THE NEW BUILDING WHILE
 THE JUSTIFICATION STATEMENT SHOWS 1,620 ADDITIONAL
 SQUARE FEET. THE REQUIRED DRAWINGS WILL ALLOW STAFF TO
 SORT OUT THE DIFFERENCES AND VERIFY IF THERE IS AN
 INCREASE IN SQUARE FOOTAGE. NOTE: IF THERE IS AN
 ADDITION OF MORE THAN 1,000 SQUARE FEET, WHILE NOT
 TRIGGERING THE THRESHOLD OF A LEVEL III SITE PLAN
 REVIEW, IT TRIGGERS A LEVEL II SITE PLAN REVIEW, WHICH
 IS HAS A $1,500 FEE, THOUGH DUE TO THE NATURE OF THE
 CHANGES NO ENGINEERING FEE IS REQUIRED. THE PLANS WILL
 BE REVIEWED BY LANDSCAPE, BUILDING AND FIRE. PLEASE
 HOLD OFF ON PAYMENT UNTIL STAFF HAS DETERMINED IF THE
 ADDITIONAL FEE IS REQUIRED.