| 2019-11-15 11:54:30 | 1. ONE PREVIOUS PERMIT PROVISO WAS FOR THE INSTALLATION |
| | OF A SIGN ON THE WEST SIDE OF THE WEST EGRESS DRIVE ON |
| | THE OKEECHOBEE BOULEVARD FRONTAGE, INDICATING THE |
| | DIRECTION OF THE PEDESTRIAN PATHWAY ENTRANCE TO THE |
| | COHEN PAVILION. THIS WILL NEED TO BE INSTALLED PRIOR TO |
| | FINAL CO. |
| | 2. THERE ARE SOME DISCREPANCIES IN THE TRUNCATED DOMES |
| | ALONG TAMARIND AVENUE AND OKEECHOBEE BOULEVARD AT THE |
| | PROJECT?S SOUTHWEST CORNER. NONE OF THE PREVIOUS |
| | PERMITS SHOWED THE SECOND EXTENDED TRUNCATED DOME ON |
| | THE OKEECHOBEE BOULEVARD SIDE. IF THIS WILL REMAIN, A |
| | PRIOR PERMIT WILL NEED TO BE AMENDED (SHEET AE110). |
| | 3. PLEASE REMOVE THE STRIPING FROM THE PROPOSED SOD |
| | AREA AT THE PROJECT?S SOUTHWEST CORNER (SHEET AE110). |
| | 4. NO PRIOR PERMITS HAVE BEEN FOUND THAT SHOW THE |
| | EXTENDED DRIVE AISLE MEDIANS AND THE RELOCATION OF THE |
| | GARAGE ENTRANCE GATES ON THE TAMARIND AVENUE. THESE |
| | GATES CANNOT BE WITHIN THE MINIMUM SETBACK, WHICH |
| | MEASURED FROM THE BACK OF CURB IS 18?. PLEASE SHOW THE |
| | EXISTING CURB LINE AND PROVIDE A SETBACK MEASUREMENT. |
| | THESE CHANGES, IF MEETING REGULATIONS, WILL NEED TO BE |
| | APPROVED WITH A PERMIT. (SHEET AE400, AE405) |
| | 5. IT APPEARS THAT THERE WILL BE RESTRIPING WITHIN THE |
| | EXISTING PARKING GARAGE. NO PERMITS HAVE BEEN LOCATED |
| | FOR THESE CHANGES, PLEASE SUBMIT A SEPARATE PERMIT IF |
| | MODIFICATIONS ARE BEING MADE. (SHEETS AE400, AE401, |
| | AE403) |
| | 6. PLEASE FIX THE SMALL ERRORS IN THE DRAWINGS IN THE |
| | PROPOSED RESTRIPING AREA ON SHEET AE403 (TWO ADA |
| | PARKING SIGNS IN MIDDLE OF DRIVE AISLE). |
| | 7. PLEASE NOTE, STAFF HAS NOT YET SEEN SEPARATE PERMIT |
| | FOR PROPOSED SIGNAGE ON EXISTING PARKING GARAGE (ON THE |
| | PROPOSED NEW SCREENING). A SEPARATE PERMIT WILL BE |
| | REQUIRED PRIOR TO INSTALLATION (THIS HAS NO IMPACT TO |
| | THESE MINOR AMENDMENT PLANS) |
| | 8. THE ELEVATIONS OF THE COHEN PAVILION PORTE COCHERE |
| | APPEAR TO BE INCORRECT AND DO NOT MATCH PREVIOUS PLANS |
| | (E.G. PERMIT 19021279). PLEASE CLARIFY (SHEET AE500). |
| | 9. PLEASE NOTE A SEPARATE FENCE PERMIT WILL BE REQUIRED |
| | FOR THE PROPOSED FENCE ON THE TAMARIND AVENUE FRONTAGE |
| | (FOR THE ELECTRICAL EQUIPMENT). |
| | 10. PLEASE AMEND THE PHOTOMETRIC PLANS. THE PROPOSED |
| | LIGHT FIXTURES ALONG OKEECHOBEE BOULEVARD SHOULD BE AT |
| | THE BACK OF THE SIDEWALK, AS PREVIOUSLY DISCUSSED WITH |
| | ANA MARIA APONTE, CITY URBAN DESIGNER. |
| | |
| | |
| | LIZ LEVESQUE, URBAN DESIGN PLANNER |
| | [email protected] |