Plan Review Details - Project Z19100016
| Plan Review Stops For Project Z19100016 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
11-12-2019 |
|
|
Cont ID |
|
| Sent By |
rbrown |
Date |
11-12-2019 |
Time |
18:22 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
11-12-2019 |
Time |
18:22 |
Sent To |
|
|
| Notes |
| 2019-11-12 18:35:49 | DEVELOPMENT SERVICES DEPARTMENT, BUILDING DIVISION, | | | COMMENTS: | | | | | | 1. THIS REVIEW IS A CURSORY REVIEW AS IT RELATES TO THE | | | SITE. IT IS NOT A REVIEW FOR FULL COMPLIANCE WITH | | | FLORIDA BUILDING CODE. THE FOLLOWING COMMENTS ARE TO BE | | | ADDRESSED FOR THE BUILDING PERMIT APPLICATION. | | | | | | 2. NUMBER OF ACCESSIBLE PARKING SPACES. SITE PLAN, | | | SHEET SP-1, STATES THAT 67 PARKING SPACES WILL BE | | | PROVIDED AND 3 WILL BE ACCESSIBLE PARKING SPACES, THE | | | PLAN SHOWS MORE THAN 50 PARKING SPACES IN THE PARKING | | | LOT BETWEEN THE RETAIL AND THE CAR WASH BUT IT SHOWS | | | ONLY 2 ACCESSIBLE PARKING SPACES. 3 ACCESSIBLE PARKING | | | SPACES ARE REQUIRED. THE MINIMUM NUMBER OF ACCESSIBLE | | | PARKING SPACES PROVIDED SHALL BE IN ACCORDANCE WITH | | | SECTION 208.2 OF FLORIDA ACCESSIBILITY CODE. | | | | | | 3. LOCATION OF ACCESSIBLE PARKING SPACES. PER SECTION | | | 208.3 OF FLORIDA ACCESSIBILITY CODE, ACCESSIBLE PARKING | | | SPACES ARE TO BE LOCATED ON THE SHORTEST POSSIBLE ROUTE | | | OF TRAVEL FROM ADJACENT PARKING TO AN ACCESSIBLE | | | ENTRANCE. THE DESIGN OF ACCESSIBLE PARKING SPACES SHALL | | | COMPLY WITH SECTION 502 OF FLORIDA ACCESSIBILITY CODE. | | | | | | 4. BUILDING SIZE. WHEN SUBMITTED FOR BUILDING PERMIT, | | | THE PLANS SHALL SHOW THAT THE TYPE OF CONSTRUCTION FOR | | | THE BUILDINGS WILL BE IN ACCORDANCE WITH THE HEIGHT, | | | AREA AND OCCUPANCY LIMITATIONS IN CHAPTER 5 OF THE | | | FLORIDA BUILDING CODE. | | | | | | 5. BUILDING LOCATION RELATIVE TO THE PROPERTY LINE AND | | | OTHER STRUCTURES. WHEN SUBMITTED FOR BUILDING PERMIT, | | | COMPLIANCE WITH ALL BUILDING SEPARATION, PERCENTAGE OF | | | OPENINGS AND OPENING PROTECTIVE REQUIREMENTS OF | | | CHAPTERS 6 AND 7 OF THE FLORIDA BUILDING CODE SHALL BE | | | VERIFIED. | | | | | | 6. OIL AND PETROLEUM INTERCEPTOR. AN OIL AND PETROLEUM | | | INTERCEPTOR WILL BE REQUIRED FOR THE CAR WASH. PLEASE | | | CONTACT JEFFREY ODOMS, UTILITIES O&M SUPERINTENDENT, | | | PUBLIC UTILITIES DEPARTMENT, FATS OILS AND GREASE | | | DIVISION, AT (561) 822-2172, OR BY EMAIL: | | | [email protected] | | | | | | 7. SEPARATE PERMITS REQUIRED. ALL APPLICABLE PERMITS | | | AND SUB-PERMITS MUST BE OBTAINED BEFORE COMMENCING THE | | | WORK. SEPARATE PERMITS, PLANS AND FEES, ARE REQUIRED | | | FOR SIGNS, GAS SYSTEMS, GENERATORS, FIRE ALARM SYSTEMS, | | | FIRE SPRINKLER AND OTHER FIRE SUPPRESSION SYSTEMS, | | | GREASE INTERCEPTORS, SITE LIGHTING, SITE LANDSCAPE, | | | SITE IRRIGATION, ETC. | | | | | | 8. CONTRACTOR VEHICLE PARKING. PROPERTY OWNER AND | | | CONTRACTOR SHALL MAKE ARRANGEMENTS FOR PARKING OF | | | CONTRACTOR VEHICLES TO MINIMIZE THE IMPACT ON ALL | | | NEIGHBORING PROPERTIES. | | | | | | 9. PROTECTION OF NEIGHBORING PROPERTY. PROPERTY OWNER | | | AND CONTRACTOR SHALL PROTECT ALL NEIGHBORING PROPERTY, | | | INCLUDING VEHICLES, FROM DAMAGE OR DIRT CAUSED BY THE | | | CONSTRUCTION, AND SHALL NOTIFY THE OCCUPANTS OF | | | NEIGHBORING PROPERTIES ABOUT ALL STAGES OF CONSTRUCTION | | | THAT MAY AFFECT THE USE OF THEIR PROPERTY. | | | | | | 10. BUILDING ADDRESS. EACH SEPARATE BUILDING, AND UNIT | | | WITH AN INDEPENDENT ENTRANCE FROM THE STREET, SHALL | | | HAVE A SEPARATE ADDRESS. FOR STREET ADDRESSING, CONTACT | | | MICHAEL ORIO, GIS SUPPORT SPECIALIST, AT (561) 494 | | | 1080, OR BY EMAIL: [email protected] | | | | | | 11. ART IN PUBLIC PLACES. THIS PROJECT MAY BE SUBJECT | | | TO ART IN PUBLIC PLACES (AIPP) ASSESSMENT. FOR ADVICE | | | ON THE PROVISION OF PUBLIC ARTWORK IN LIEU OF THE AIPP | | | ASSESSMENT, CONTACT SYBILLE WELTER, ART IN PUBLIC | | | PLACES COORDINATOR, AT (561) 822-1521, OR BY EMAIL: | | | [email protected] | | | | | | ROBERT BROWN | | | BUILDING OFFICIAL | | | TEL: 561 805 6652 | | | EMAIL: [email protected] | | | |
|
|
| Review Stop |
ENG - PPRC |
ENGINEERING - PPRC |
| Rev No |
1 |
Status |
F |
Date |
11-12-2019 |
|
|
Cont ID |
|
| Sent By |
rrossano |
Date |
11-12-2019 |
Time |
|
Rev Time |
4.00 |
| Received By |
rrossano |
Date |
11-12-2019 |
Time |
|
Sent To |
|
|
| Notes |
| 2019-11-12 15:19:29 | 1. PLEASE RESPOND IN WRITING TO ALL COMMENTS WITH Z | | | PERMIT NUMBER, PROJECT NAME AND ADDRESS. | | | 2. PLANS SHALL SHOW PROPOSED LOCATIONS AND DIMENSIONS | | | OF ALL WATER, STORMWATER, AND SANITARY AND SEWER LINES, | | | INCLUDING STUBS TO EACH PROPERTY LINE FOR WATER AND | | | SANITARY SEWERS, THE MAKE AND MODEL OF ALL VALVES, | | | METERS, AND OTHERS DEVICES TO BE INSTALLED ON THE | | | SYSTEM, CATCH BASINS, CULVERTS, DITCHES INCLUDING | | | GRADES, PIPES SIZES, MATERIALS, ELEVATIONS, | | | ASSUMPTIONS, CALCULATIONS, INVERT ELEVATIONS FOR ALL | | | INLETS AND MANHOLES AND PROFILES OF SANITARY SEWER | | | LINES. ALL AVAILABLE ELEVATION SHALL BE SHOWN ON THE | | | PROFILE VIEW. DIRECTION OF FLOW SHALL BE SHOWN ON PLAN | | | VIEW ON PLAN VIEW FOR ALL SANITARY AND STORM SEWERS. | | | PLEASE SHOW SLOPE % ON ALL SANITARY LINES AND CALL OUT | | | MATERIAL. ADDITIONALLY, PLAN VIEW SHALL SHOW ALL | | | EXISTING AND PROPOSED UNDERGROUND UTILITY LAYOUT, | | | INCLUDING FIBER OPTIC, ELECTRIC, GAS, AND CABLEVISION & | | | TELECOMMUNICATION FACILITIES LOCATED ON THE | | | RIGHT-OF-WAY. PROVIDE PROFILE AND CLEARANCES AT ALL | | | UTILITY CROSSINGS. | | | 3. CUT AND CAP UTILITIES NOT IN USE, AND REMOVE ANY | | | ABANDONED UTILITY LINES LARGER THAN 2 INCHES FROM CITY | | | RIGHT OF WAY. | | | 4. PLEASE SUBMIT COMPLETED LOS ANALYSIS SUMMARY TABLE | | | DIRECTLY TO ENGINEERING (SHEET 33 OF CITY OF WPB | | | DEVELOPMENT APPLICATION). | | | 5. PROVIDE CALCULATIONS ON PLANS OF EXISTING AND | | | PROPOSED DEMANDS FOR WATER & SEWER (AVERAGE, MAXIMUM | | | AND PEAK) AND FIRE FLOW DEMANDS. CALCULATIONS SHALL BE | | | PER FAC 64E-6 FOR SEWER AND PER FAC 64-E.008 FOR WATER. | | | 6. SHOW VERTICAL DATUM AND DATUM CONVERSION INFORMATION | | | (NAVD 88 AND NGVD 29). | | | 7. PROVIDE CCTV VIDEO OF EXISTING SANITARY SEWER ALONG | | | ENTIRE PROJECT FRONTAGE. | | | 8. PLEASE PROVIDE CALCULATIONS OF REVISED PERVIOUS AND | | | IMPERVIOUS CALCULATIONS FOR THE PROPOSED IMPACTED | | | AREAS. | | | 9. PROVIDE ONSITE CLEANOUTS NEAR PROPERTY LINE FOR | | | PROPOSED SANITARY LATERALS. | | | 10. PLEASE LABEL WATER LINES AS PRIVATE WHERE | | | APPLICABLE. | | | 11. COORDINATE WITH MARK HURLEY, FIELD CUSTOMER SERVICE | | | SUPERVISOR WITH CITY OF WPB PUBLIC UTILITIES, REGARDING | | | PLACEMENT OF BACKFLOW DEVICES AND WATER METERS. CONTACT | | | HIM AT 561-494-2262 OR [email protected] | | | 12. PROVIDE DEDICATED UTILITY EASEMENTS TO ALLOW ACCESS | | | FOR CITY PERSONNEL TO PROPOSED UTILITY WATER METERS | | | 13. PLEASE CHECK TO SEE IF FDEP FORMS ARE NEEDED. | | | 14. PLEASE CLEARLY LABEL CITY OF WPB POINTS OF SERVICE | | | FOR UTILITY CONNECTIONS. | | | 15. FOR FORMAL ENGINEERING SUBMITTAL, PLEASE PROVIDE | | | ENLARGED VIEW ON PLANS OF PROPOSED LOCATION OF WATER | | | METER AND BACKFLOW PREVENTION. INCLUDE EASEMENT | | | DEDICATION FOR WATER METER. | | | 16. FOR FORMAL ENGINEERING SUBMITTAL, PLEASE CALLOUT | | | DOMESTIC BACKFLOW PREVENTER AS RPPA AND FIRE BACKFLOW | | | PREVENTER AS DCDA. SPECIFY LEAD FREE DESIGN ON ALL | | | BACKFLOWS. | | | 17. FOR FORMAL ENGINEERING SUBMITTAL, PROVIDE PROFILES | | | OF WATER AND SEWER AND SHOW ANY CROSSINGS/CONFLICTS. | | | 18. FOR FORMAL ENGINEERING SUBMITTAL, WHEN SUBMITTING | | | APPROVED MATERIALS LIST, PLEASE PROVIDE MATERIAL/CUT | | | SHEETS FOR ALL PROPOSED BACKFLOW DEVICES SHOWING | | | SPECIFIC MODEL NUMBER AND SPECIFYING USC APPROVED | | | LEAD-FREE DESIGN. | | | | | | THE FOLLOWING COMMENTS ARE FROM MARK HURLEY, FIELD | | | CUSTOMER SERVICE SUPERVISOR, PUBLIC UTILITIES: | | | 1. PLAN DOES NOT SHOW UTILITY EASEMENTS AROUND THE FIRE | | | HYDRANTS AND METERS FOR BOTH EXISTING AND NEW. SMALL UE | | | SHOULD BE CREATED AROUND THEM AND SERVICE PIPE TO THEM | | | THAT SITS ON THE PRIVATE PROPERTY. THE UE SHOULD | | | EXCLUDE THE BACKFLOW ASSEMBLIES. | | | 2. PLAN ALSO MISSING THE PIPING FROM WATER MAIN TO THE | | | EXISTING WATER SERVICES. | | | 3. PLAN SHOWS 2 FIRE HYDRANTS ON SITE. THE SOUTHERN | | | FIRE HYDRANT IS PROBLEMATIC BECAUSE THE PIPE FEEDING IT | | | RUNS UNDER THE ENTRANCE, SO IF ANY MAINTENANCE NEED BE | | | DONE THERE IT WOULD STOP THE FLOW OF TRAFFIC. IS THAT | | | FIRE HYDRANT REQUIRED TO BE THERE, OR COULD IT BE | | | ELIMINATED? (ALSO VALVE TURNING OFF HYDRANT IS IN | | | MIDDLE OF ENTRANCE ROAD -> SAFETY HAZARD) | | | | | | FEEL FREE TO CONTACT US IF YOU HAVE ANY QUESTIONS OR | | | CONCERNS, THANKS. | | | | | | RICK ROSSANO, PROJECT COORDINATOR | | | ENGINEERING SERVICES DEPARTMENT | | | DIRECT: (561) 494-1098 | | | [email protected] | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
11-06-2019 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
11-06-2019 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
11-06-2019 |
Time |
11:14 |
Sent To |
|
|
| Notes |
| 2019-11-06 11:25:16 | THE FOLLOWING COMMENTS WERE SUBMITTED BY PETER LEDUC, | | | FIRE MARSHAL, BUREAU OF FIRE PREVENTION, WEST PALM | | | BEACH FIRE RESCUE. | | | | | | THIS REVIEW CAN ONLY BE CONSIDERED PRELIMINARY AS THE | | | DRAWINGS THAT WERE REVIEWED WERE NOT COMPLETE. | | | ADDITIONAL COMMENTS CAN BE EXPECTED WHEN FULL DRAWINGS | | | ARE SUBMITTED FOR PERMIT. | | | | | | THE FIRE PREVENTION BUREAU HAS NO OBJECTIONS TO THE | | | PROPOSED PROJECT. | | | | | | 1. CONSTRUCTION, DEMOLITION, AND RENOVATION TO COMPLY | | | WITH NFPA 241. EXTRA ATTENTION SHALL BE GIVEN TO THE | | | PERMITTING AND LOCATION OF CONSTRUCTION TRAILERS. A | | | PERMIT IS REQUIRED FOR ANY CONSTRUCTION TRAILER RELATED | | | TO THIS PROJECT. SEPARATION DISTANCES FROM MAIN | | | STRUCTURES AS WELL AS OTHER TRAILERS SHALL BE CLOSELY | | | MONITORED FOR THE REQUIREMENTS OF FIRE SPRINKLER | | | PROTECTION. | | | | | | 2. SITE ACCESS AND EXIT POINTS ARE TO BE CLEARLY | | | IDENTIFIED AND MAINTAINED FOR EMERGENCY VEHICLES DURING | | | ALL CONSTRUCTION ACTIVITIES. | | | | | | 3. THE BUILDING ADDRESS SHALL BE CLEARLY VISIBLE FROM | | | ALL ACCESS ROADWAYS, INCLUDING DURING CONSTRUCTION. | | | ADDRESS NUMBERS SHALL CONTRAST WITH THEIR BACKGROUND | | | AND SHALL NOT BE LESS THAN SIX (6) INCHES IN HEIGHT | | | WITH A ONE (1) INCH STROKE FOR ALL BUILDINGS. | | | | | | 4. DURING CONSTRUCTION, TRASH AND DEBRIS IS TO BE | | | REMOVED FROM THE SITE DAILY OR MORE OFTEN TO REDUCE THE | | | ACCUMULATION OF POTENTIAL LIFE AND FIRE SAFETY HAZARDS. | | | | | | 5. THE CONSTRUCTION OF THE BUILDING SHALL COMPLY WITH | | | THE 6TH EDITION OF THE FLORIDA FIRE PREVENTION CODE, | | | INCLUDING NFPA 1 & 101, AND ALL ASSOCIATED FIRE CODES. | | | | | | 6. FOR PLAN REVIEW SUBMITTAL, PLEASE INCLUDE THE | | | PROPOSED OCCUPANCY TYPE, PER THE FLORIDA FIRE | | | PREVENTION CODE, AND WHETHER IT IS MIXED OR SEPARATED | | | OCCUPANCY. | | | | | | 7. FOR PLAN REVIEW SUBMITTAL, PLEASE ENSURE THAT A FIRE | | | LOAD CALCULATION IS INCLUDED AND THAT ADEQUATE WATER | | | SUPPLY IS EXISTING OR WILL BE PROVIDED. | | | | | | 8. ALL EXISTING AND NEW FIRE HYDRANTS PLANNED FOR THIS | | | DEVELOPMENT SHALL BE CLEARLY INDICATED AND IDENTIFIED | | | ON THE PLAN AND CLOSELY COORDINATED WITH THE BUREAU OF | | | FIRE PREVENTION. | | | | | | THE EXISTING FIRE HYDRANT INDICATED ON THE REVIEW | | | SUBMITTAL IS IN AN ACCEPTABLE LOCATION. | | | | | | ANY NEW FIRE HYDRANTS AND/OR FDC?S PLANNED FOR THIS | | | DEVELOPMENT SHALL BE CLOSELY COORDINATED WITH THE | | | BUREAU OF FIRE PREVENTION. PROPOSED FIRE HYDRANTS AND | | | FDC?S SHOULD BE LOCATED ON THE SAME SIDE OF THE STREET | | | OR ACCESS ROADWAY TO ALLOW FREE ACCESS FOR OTHER | | | ARRIVING EMERGENCY VEHICLES. | | | | | | 9. PROVIDE FOR A FIRE SPRINKLER AND/OR FIRE ALARM PER | | | THE APPLICABLE OCCUPANCY CODE. FOR ANY LIFE SAFETY | | | ENGINEERED SYSTEM, I.E FIRE SPRINKLER AND FIRE ALARM, | | | ENSURE THEY COMPLY WITH THE REQUIREMENTS OF FS 61G AND | | | SUBMITTED WITH THE MASTER PLAN. | | | | | | 10. COMPLETE LIFE SAFETY PLANS FOR EACH OCCUPANCY SHALL | | | BE PROVIDED THAT ILLUSTRATE OCCUPANT LOADS, TRAVEL | | | DISTANCES, COMMON PATHS OF TRAVEL, DEAD-END CORRIDORS, | | | EXIT SIGNS, EMERGENCY LIGHTING, EXITS LEADING TO A | | | PUBLIC WAY, FIRE EXTINGUISHER LOCATIONS, AND ALL FIRE | | | SAFETY FEATURES AND EQUIPMENT. | | | | | | 11. IT IS HIGHLY RECOMMENDED (REQUIRED WITH FIRE | | | SPRINKLER SYSTEM) THAT A KNOX BOX WITH KEYS FOR ENTRY | | | DOOR LOCKS BE PROVIDED FOR 24 HOUR EMERGENCY ACCESS. | | | | | | 12. THE BUREAU'S APPROVAL OF THIS SUBMITTED PROJECT | | | DOES NOT CONSTITUTE ITS FINAL REVIEW OR APPROVAL. | | | | | | 13. THE BUREAU SHALL REVIEW ALL SUBMITTED BUILDING | | | PLANS AT THE APPROPRIATE TIME AND IN ACCORDANCE WITH | | | THE REQUIREMENTS OF ALL APPLICABLE CODES AND STANDARDS. | | | | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
1 |
Status |
F |
Date |
11-12-2019 |
|
|
Cont ID |
|
| Sent By |
rcaranci |
Date |
11-12-2019 |
Time |
12:03 |
Rev Time |
0.00 |
| Received By |
rcaranci |
Date |
11-12-2019 |
Time |
12:03 |
Sent To |
|
|
| Notes |
| 2019-11-12 12:04:14 | FROM: RAY CARANCI, LANDSCAPE PLANNER 561-822-1462 | | | PROJECT: PALM BEACH LAKES INN CPD Z19100016 | | | NOVEMBER 12, 2019 | | | I HAVE REVIEWED THE ABOVE REFERENCED PETITION, AND | | | PROVIDE THE FOLLOWING COMMENTS: | | | | | | 1. PROVIDE A SEPARATE TREE DISPOSITION PLAN AND CHART | | | FOR THE TREES WITHIN THE AFFECTED AREA AND INDICATE IF | | | THEY WILL BE PRESERVED IN PLACE, RELOCATED OR REMOVED. | | | LIST THE BOTANICAL NAME AND PROVIDE THE CANOPY | | | DIAMETER. CALCULATE THE REQUIRED MITIGATION IN SQUARE | | | FOOTAGE FOR ANY REMOVALS. REMOVE THE LAYER FROM | | | LANDSCAPE PLAN. LIST ONLY TREES THAT ARE RELOCATED OR | | | EXISTING ON THE PLANT LIST AND THE LANDSCAPE PLAN. | | | CALCULATE AND LIST PROVIDED TREE MITIGATION. | | | | | | 2. REQUIRED OPEN SPACE FOR CALCULATING REQUIRED SHADE | | | TREES AND FLOWERING TREES IS 40%. SHOW THE SQUARE | | | FOOTAGE ON THE REQUIREMENTS CHART AND RECALCULATE. | | | | | | 3. SHOW THE TOTAL SQUARE FOOTAGE AND PERCENTAGE FOR 15% | | | LANDSCAPE AREA REQUIRED FOR EACH PARCEL. | | | | | | 4. SHOW THE PERCENTAGE AND NUMBER OF PALM SUBSTITUTIONS | | | FOR REQUIRED TREES NOT EXCEEDING 35 PERCENT PER SECTION | | | 94-442 (D). | | | | | | 5. PROVIDE A PLAN SHOWING THE PARKING LANDSCAPE AREAS | | | COUNTED TOWARD COMPLIANCE WITH SECTION 94-443(C)(3) AND | | | (4) AND PROVIDE CALCULATIONS. | | | | | | 6. PROVIDE CALCULATIONS FOR REQUIRED BUFFER TREES AT | | | ONE FOR EVERY 30 FEET OR PORTION THEREOF FOR ALL BUFFER | | | LENGTHS CORRECTLY ROUNDING UP. PARCEL 1- EAST AND SOUTH | | | ARE 8 TREES REQUIRED. PARCEL 2- NORTH IS 10 TREES | | | REQUIRED. | | | | | | | | | 7. PROVIDE HEDGES TO SCREEN ALL PARKING AREAS FROM | | | ADJACENT PROPERTIES AND STREETS. PARCEL 1 NEEDS TO SHOW | | | THIS REQUIREMENT IS MET. | | | | | | | | | 8. SHOW LINEAR FOOTAGE OF LANDSCAPED AREA ADJACENT TO | | | THE BUILDING MEETS THE REQUIREMENT OF 30 PERCENT PER | | | SECTION 94-443(E)(1) FOR EACH BUILDING. | | | | | | 9. ADD COLUMNS FOR NATIVE AND DROUGHT TOLERANCE TO THE | | | PLANT LIST. | | | | | | | | | 10. SHOW COMPLIANCE WITH SECTION 94-445 L. PLANT | | | SPECIES. A MINIMUM OF 60 PERCENT OF PLANT MATERIAL | | | ADDED SHALL BE FLORIDA NATIVE OR DROUGHT TOLERANT | | | SPECIES SELECTED FROM THE CITY LIST OR THE LIST OF | | | SPECIES IN THE MOST RECENT EDITION OF SOUTH FLORIDA | | | WATER MANAGEMENT DISTRICT WATERWISE SOUTH FLORIDA | | | LANDSCAPES. | | | PROVIDE THE TOTAL PERCENTAGE BASED ON FINAL PLANT LIST. | | | | | | 11. THE LOCATIONS OF DRAINAGE, WATER AND SEWER LINES ON | | | THE LANDSCAPE PLAN SHOW SOME CONFLICTS WITH TREES AND | | | LANDSCAPING. RELOCATE UTILITY LOCATIONS OR EXPAND | | | LANDSCAPE AREAS TO ACCOMMODATE REQUIRED LANDSCAPING. | | | | | | 12. THERE ARE MULTIPLE AREAS OF EASEMENTS THAT MAY | | | RESTRICT PLANTING OF TREES. CLEARLY INDICATE AND LABEL | | | ALL EASEMENTS THAT WILL REMAIN. | | | | | | 13. SHOW LOCATIONS OF FPL TRANSFORMERS ON THE LANDSCAPE | | | PLAN AND RESOLVE CONFLICTS WITH LANDSCAPING. PROVIDE | | | SCREENING FOR ALL GROUND MOUNTED VALVES AND EQUIPMENT. | | | | | | | | | 14. PROVIDE A DETAIL AND LOCATIONS OF ROOT BARRIERS TO | | | SEPARATE LANDSCAPING FROM UTILITY LINES. | | | | | | | | | 15. SHOW THE LOCATIONS OF ALL SITE LIGHTING ON THE | | | LANDSCAPE PLAN AND RESOLVE ANY CONFLICTS WITH TREES. | | | CONDITIONS OF APPROVAL | | | 1. PRIOR TO THE REMOVAL OR RELOCATION OF ANY TREES ON | | | THE PROPERTY, A TREE ALTERATION PERMIT SHALL BE | | | SUBMITTED, REVIEWED AND APPROVED BY THE DEVELOPMENT | | | SERVICES DEPARTMENT, PLANNING DIVISION. | | | |
|
|
| Review Stop |
PW |
PUBLIC WORKS |
| Rev No |
1 |
Status |
F |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
|
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2019-11-04 15:19:04 | - FOR A FREESTANDING SITE DUMPSTER ENCLOSURE, THE | | | ENCLOSURE SHALL COMPLY WITH THE LATEST REVISION OF CITY | | | OF WEST PALM BEACH GENERAL CONSTRUCTION-GARBAGE | | | ENCLOSURE STANDARD, CG-8. THE SITE PLAN SHALL REFLECT | | | THE LATEST SPEC FOR THE DUMPSTER ENCLOSURE. | | | - PLEASE PROVIDE AUTO TURN FOR THE SANITATION SERVICE | | | - PLEASE CONSIDER RELOCATING THE LOADING ZONE AND/OR | | | THE ENCLOSURE ON THE SIDE OF MARATHON RETAIL BUILDING | | | SINCE IT COULD BLOCK ACCESS TO THE DUMPSERS. | | | | | | | | | MATT HEJAZI | | | DEPT. OF PUBLIC WORKS | | | [email protected] | | | 561-822-2045 | | | |
|
|
| Review Stop |
STORM |
STORMWATER |
| Rev No |
1 |
Status |
F |
Date |
11-13-2019 |
|
|
Cont ID |
|
| Sent By |
tward |
Date |
11-13-2019 |
Time |
09:26 |
Rev Time |
0.00 |
| Received By |
tward |
Date |
11-13-2019 |
Time |
09:27 |
Sent To |
|
|
| Notes |
| 2019-11-13 09:26:27 | THIS IS A CONCEPTUAL LEVEL REVIEW. CONSTRUCTION LEVEL | | | DETAILS, DESIGN CALCULATIONS AND THE POLLUTION | | | PREVENTION PLAN WILL BE REVIEWED AS PART OF THE | | | ENGINEERING DEVELOPMENT APPROVAL AND BUILDING PERMIT | | | APPLICATION PROCESSES. THE ENGINEERING DEVELOPMENT | | | APPROVAL APPLICATION FORMS CAN BE DOWNLOADED AT | | | | | | HTTPS://WPB.ORG/DEPARTMENTS/ENGINEERING-PUBLIC-WORKS/FO | | | R MS,-PERMITS-APPLICATIONS | | | | | | THE FOLLOWING COMMENTS MUST BE ADDRESSED PRIOR TO SITE | | | PLAN APPROVAL: | | | | | | 1. PROVIDE A COPY OF THE DRAINAGE EASEMENT CROSSING | | | EXECUTIVE CENTER DRIVE. | | | | | | 2. SHOW DRAINAGE EASEMENT ON THE ADJACENT PROPERTY. | | | | | | 3. CONSIDER REDUCING THE PARKING SPACE DEPTHS AND | | | PROVIDE TWO FEET OF PERVIOUS OVERHANG. | | | | | | 4. SHOW ALL OF THE DRAINAGE PIPES AT THE EXISTING INLET | | | THAT IS BEING USED. | | | | | | 5. LIST VERTICAL DATUM ON THE ENGINEERING PLANS AND | | | PROVIDE CONVERSION EQUATION TO NGVD1929. | | | | | | 6. IDENTIFY THE ADDITIONAL LINES CONNECTED TO THE STORM | | | MANHOLE ON THE SURVEY. | | | | | | 7. ROOT BARRIERS WILL BE NEEDED BETWEEN LANDSCAPING AND | | | UNDERGROUND UTILITIES. | | | | | | THE FOLLOWING COMMENTS MUST BE ADDRESSED PRIOR TO | | | ISSUANCE OF CONSTRUCTION AUTHORIZATION INCLUDING | | | BUILDING PERMITS AND ENGINEERING DEVELOPMENT APPROVAL. | | | | | | 1. AN ENGINEERING DEVELOPMENT APPROVAL APPLICATION MAY | | | BE REQUIRED FROM THE ENGINEERING SERVICES DEPARTMENT. | | | THE ENGINEERING DEVELOPMENT APPROVAL APPLICATION FORMS | | | CAN BE DOWNLOADED AT: HTTP://WPB.ORG/DEPARTMENTS/ENGINE | | | ERING-PUBLIC-WORKS/FORMS,-PERMITS-APPLICATIONS | | | | | | 2. EROSION CONTROL PLAN AND DETAILS TO BE SUBMITTED | | | WITH THE ENGINEERING PERMIT APPLICATION. | | | | | | 3. PROVIDE A COPY OF THE SFWMD ERP PERMIT PRIOR TO | | | STARTING CONSTRUCTION. | | | | | | TRACY WARD, PE | | | SENIOR STORMWATER ENGINEER | | | ENGINEERING SERVICES DEPARTMENT | | | 561-494-1120 | | | [email protected] | | | |
|
|
| Review Stop |
SURVEY |
SURVEYING |
| Rev No |
1 |
Status |
F |
Date |
11-13-2019 |
|
|
Cont ID |
|
| Sent By |
vnoel |
Date |
11-13-2019 |
Time |
07:44 |
Rev Time |
|
| Received By |
vnoel |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2019-11-13 07:44:44 | 1. REPLAT WILL BE REQUIRED THROUGH ENGINEERING. | | | 2. IS THERE A CROSS-ACCESS AGREEMENT WITH BEST BUY? | | | 3. IS THERE AN EXISTING WATER SERVICE AT SOUTH END? IF | | | NEW SERVICE PROPOSED, EXISTING WILL NEED TO BE CUT BACK | | | TO MAIN. | | | 4. METER LOCATION WILL NEED TO BE APPROVED BY CUSTOMER | | | SERVICE. | | | 5. MAINTENANCE AGREEMENT MAY BE REQUIRED FOR EXISTING | | | TREES/TREE GRATES IN RIGHT-OF-WAY. |
|
|
| Review Stop |
TRAFFIC |
TRAFFIC ENGINEERING |
| Rev No |
2 |
Status |
F |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
11-12-2019 |
Time |
|
Rev Time |
0.00 |
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2019-11-12 14:56:00 | ***1ST REVIEW FROM TRAFFIC*** | | | *** REVISED TRAFFIC STUDY COMMENTS 2019-11-13**** | | | | | | SITE PLAN COMMENTS: | | | 5. PROVIDE BICYCLE LANES ON EXECUTIVE CENTER DRIVE. | | | 6. PROVIDE MEDIAN PEDESTRIAN REFUGE ISLAND AND | | | CROSSWALK ACROSS EXECUTIVE CENTER DRIVE JUST NORTH OF | | | THE SOUTHERN DRIVEWAY. | | | 7. PROVIDE PEDESTRIAN CONNECTION ALONG THE NORTHERN | | | BOUNDARY OF PARCEL 1 TO CONNECT TO THE RETAIL, AND | | | CONNECT THE EXISTING SIDEWALK WHICH RUNS ALONG THE | | | SOUTHWEST PERIMETER OF THE EXISTING CONVENIENT STORE | | | BUILDING TO THIS PEDESTRIAN CONNECTION. | | | 8. DIMENSION THE SIDEWALK WIDTH. | | | 9. INCLUDE THE REQUIRED BICYCLE PARKING ON THE SITE | | | DATA TABLE AND SITE PLAN. | | | 10. REDUCE THE WIDTH OF THE ONE-WAY DRIVEWAY FROM | | | EXECUTIVE CENTER DRIVE TO 12 FEET AT THE ENTRANCE. | | | 11. CONSIDER CONVERTING THE 18-FOOT ONE-WAY INTERNAL | | | DRIVE AISLE NEAR THE DUMPSTER TO 20-FOOT TWO-WAY DRIVE | | | AISLE FOR INTERNAL CIRCULATION. STRAIGHTEN THIS DRIVE | | | AISLE AND PROVIDE STOP BAR, STOP SIGNS, RIGHT-TURN ONLY | | | SIGNS, AND ONE-WAY SIGNS AS APPRECIATE TO CLARIFY | | | VEHICULAR MOVEMENTS AROUND THIS AREA. | | | 12. PROVIDE AUTOTURN PATHS FOR GARBAGE TRUCKS. | | | 13. SHOW FULL RIGHT-OF-WAY WIDTH AND RIGHT-OF-WAY WIDTH | | | FROM CENTERLINE. | | | | | | REVISED TRAFFIC COMMENTS: | | | 14. PROVIDE COUNTY TPS LETTER. | | | 15. THE EXISTING RESTAURANT APPEARS TO BE ABANDONED FOR | | | MANY YEARS. PLEASE PROVIDE EVIDENCE (E.G. EVIDENCE OF | | | ACTIVE FOOD SERVICE LICENSE) THAT THE RESTAURANT IS | | | OPERATIONAL WITHIN THE PAST 5 YEARS, OR REMOVE IT FROM | | | THE EXISTING TRIP CREDIT. | | | 16. PROVIDE INTERSECTION ANALYSIS AT PALM BEACH LAKES | | | BOULEVARD/EXECUTIVE CENTER DRIVE, AND INCLUDE 95TH | | | PERCENTILE QUEUE LENGTHS FOR NORTHBOUND AND EASTBOUND | | | MOVEMENTS. | | | 17. PLEASE REVISE THE NUMBER OF LANES FOR EXECUTIVE | | | CENTER DRIVE, WHICH IS A 2-LANE ROADWAY, IN TABLE 2. | | | 18. PLEASE REVISE THE DESCRIPTION OF DRIVEWAYS IN THE | | | TRAFFIC STATEMENT, E.G. ?EXISTING RIGHT-IN/RIGHT-OUT | | | DRIVEWAY ON EXECUTIVE CENTER DRIVE? AND ?RIGHT-OUT ONLY | | | DRIVEWAY ON PALM BEACH LAKES BOULEVARD?. | | | 19. THE DRIVEWAY VOLUMES SHOWN IN FIGURE 2 DOES NOT | | | APPEAR TO INCLUDE BEST BUY TRAFFIC VOLUMES. PLEASE | | | REVISE. | | | | | | | | | | | | SHING TSOI | | | CITY IN-HOUSE TRAFFIC CONSULTANT | | | 561-494-1141 | | | [email protected] | | | (IN-HOUSE ON TUESDAYS AND WEDNESDAYS) | | | |
|
|
| Review Stop |
TRAFFIC |
TRAFFIC ENGINEERING |
| Rev No |
1 |
Status |
F |
Date |
11-08-2019 |
|
|
Cont ID |
|
| Sent By |
rrossano |
Date |
11-08-2019 |
Time |
|
Rev Time |
4.00 |
| Received By |
rrossano |
Date |
11-08-2019 |
Time |
|
Sent To |
|
|
| Notes |
| 2019-11-08 10:20:42 | PLEASE SEE COMMENTS UNDER ENG - PPRC. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
11-13-2019 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
11-13-2019 |
Time |
12:45 |
Rev Time |
0.00 |
| Received By |
eschneid |
Date |
11-13-2019 |
Time |
12:45 |
Sent To |
|
|
| Notes |
| 2019-11-13 12:45:39 | CASE NO. PB 1060LL | | | PALM BEACH LAKES RETAIL CENTER | | | 1840 PALM BEACH LAKES BOULEVARD | | | | | | - CONTACT ERIC SCHNEIDER @ (561) 822-1446 | | | | | | - PLEASE PROVIDE RESPONSES TO REVIEW COMMENTS IN | | | WRITTEN FORMAT. | | | | | | - WHEN RESUBMITTING, PLEASE PROVIDE A MINIMUM OF ELEVEN | | | (11) PAPER COPIES AND AN ELECTRONIC COPY IN .PNG FORMAT | | | OF ALL PLANS. PLEASE NOTE THAT CHANGES ON THE | | | RESUBMITTED PLANS OR THE SUBMITTAL OF INFORMATION/PLANS | | | TO ADDRESS THE COMMENTS MAY RESULT IN ADDITIONAL | | | COMMENTS. | | | | | | - THE PPRC COMMENTS SHALL BE SUFFICIENTLY ADDRESSED AND | | | SUBMITTED TO THE PLANNING DIVISION BY 5 PM ON MONDAY | | | DECEMBER 2, 2019, TO BE ELIGIBLE TO BE SCHEDULED FOR | | | THE JANUARY 21, 2020 PLANNING BOARD MEETING. | | | | | | - PLEASE NOTE THAT IF THE PLANNING DIVISION HAS NOT | | | RECEIVED A RESPONSE TO THE PPRC COMMENTS WITHIN 60 DAYS | | | FROM THE DATE OF THESE COMMENTS/THE PPRC MEETING (BY | | | JANUARY 13, 2020), THE CASE SHALL BE CONSIDERED | | | WITHDRAWN. ANY FURTHER ACTION SHALL REQUIRE A NEW | | | DEVELOPMENT APPLICATION. | | | | | | - PLEASE NOTE THAT YOU WILL BE PERMITTED ONE (1) | | | RESUBMITTAL AT NO ADDITIONAL COST. IF PREVIOUSLY-ISSUED | | | COMMENTS CONTINUE TO NOT BE SUFFICIENTLY ADDRESSED, THE | | | APPLICANT WILL BE ASSESSED A RESUBMITTAL FEE. SUCH FEE | | | WILL BE 20% OF THE ORIGINAL APPLICATION FEE ($600). | | | | | | - PUBLIC HEARING NOTIFICATION SIGNAGE SHALL BE POSTED | | | IN ACCORDANCE WITH THE REQUIREMENTS OF SECTION | | | 94-39(I)(5) OF THE ZONING AND LAND DEVELOPMENT | | | REGULATIONS. | | | | | | 1) THE EXISTING GAS STATION AND CHINESE RESTAURANT ARE | | | PART OF WHAT WAS PARCEL 3 OF THE PALM BEACH LAKES INN | | | AND GOLF COURSE CPD AND COVERED BY ORDINANCE NO. | | | 2622-93. PLEASE PROVIDE A RESPONSE TO THE CONDITIONS | | | LISTED IN SECTION 5, SUBSECTIONS 3, 7, 8 AND 9 OF | | | ORDINANCE NO. 2622-93. | | | | | | 2) EVEN THOUGH THE TRAFFIC STATEMENT FOR THE | | | REDEVELOPMENT SHOWS A REDUCTION IN TRIPS FOR THE | | | MAJORITY OF THE TESTED TIME FRAMES, YOU ARE STILL | | | REQUIRED TO SUBMIT AN APPROVED TRAFFIC PERFORMANCE | | | STANDARDS LETTER FROM PALM BEACH COUNTY ENGINEERING. | | | THE LETTER IS REQUIRED PRIOR TO SCHEDULING FOR PLANNING | | | BOARD. | | | | | | 3) THE CITY REQUIRES THAT THE APPLICANT PAY FOR POSTAGE | | | FOR THE MAILERS. THE PROVIDED ENVELOPES DID NOT INCLUDE | | | POSTAGE. YOU ARE REQUIRED TO PROVIDE POSTAGE ON THE 16 | | | ENVELOPES VIA FOREVER STAMPS. | | | | | | 4) THE CROSS ACCESS POINT NEEDS TO BE CONSTRUCTED TO | | | THE PROPERTY LINE SO THAT WHEN THE BRANDSMART SITE IS | | | REDEVELOPED, THEIR SIDE OF THE DRIVE CAN BE DIRECTLY | | | TIED IN TO THE CONNECTION. THE LANDSCAPE NEEDS TO BE | | | ADJUSTED ACCORDINGLY. | | | | | | 5) THE CONCEPTUAL ENGINEERING PLAN SHOWS THE PROPOSED | | | CONTROL STRUCTURE AND OUTFALL PIPE WITHIN THE LANDSCAPE | | | BUFFER. THIS NEEDS TO BE RELOCATED TO UNDERNEATH THE | | | ENTRY DRIVE WITH THE CONNECTION TO THE EXISTING | | | DRAINAGE INLET PERPENDICULAR TO THE LANDSCAPE BUFFER SO | | | THAT THE LANDSCAPE BUFFER IMPACT IS AS MINIMAL AS | | | POSSIBLE. | | | | | | 6) PLEASE DESCRIBE HOW THE CAR WASH WILL FUNCTION. IS | | | IT SELF-DRIVEN, ATTENDANT DRIVEN, OR DRIVERLESS (I.E. | | | TOWED THROUGH)? STAFF HAS CONCERNS WITH THE 24 FOOT | | | STACKING DISTANCE AT THE END OF THE CAR WASH. THERE ARE | | | TIMES WHEN THERE IS A HIGH VOLUME OF TRAFFIC EXITING | | | BEST BUY AND ENTERING THE SITE. IF THERE IS A DELAY IN | | | MOVING ON FROM THE END OF THE CAR WASH, HOW WILL CARS | | | THAT ARE FOLLOWING NOT REAR END THE ONE AT THE STOP | | | SIGN? | | | | | | 7) THE CARWASH EXIT DRIVE CURBING NEEDS TO BE | | | CHANNELIZED BETTER TO PREVENT INBOUND VEHICLES FROM | | | ACCIDENTALLY ENTERING THE CAR WASH EXIT. | | | | | | 8) IS FREESTANDING SIGNAGE PROPOSED FOR THE RETAIL/CAR | | | WASH PARCEL? | | | | | | 9) THE CITY'S SANITATION DEPARTMENT NEEDS TO VERIFY | | | THAT THEY CAN PICK UP THE RELOCATED DUMPSTERS WITH THE | | | NEW ORIENTATION. PLEASE NOTE THAT THE DUMPSTER | | | ENCLOSURES DO NOT MEET THE MINIMUM CITY STANDARDS. | | | | | | 10) THE REQUIRED PARKING SPACE TOTAL IS INCORRECT. 44 | | | PARKING SPACES ARE REQUIRED. | | | | | | 11) THE MINIMUM LANDSCAPE AND OPEN SPACE CALCULATIONS | | | ON THE SITE DATA TABLE DO NOT SEEM TO BE CORRECT. | | | PLEASE VERIFY THE NUMBERS. | | | | | | 12) TURN OFF THE TREE DISPOSITION LAYER ON THE SITE | | | PLAN. THIS NEEDS TO BE SHOWN ON A SEPARATE PLAN AS IT | | | IMPEDES THE READABILITY OF THE SITE PLAN. | | | | | | 13) ARE THERE USES THAT ARE BEING PROHIBITED FROM WHAT | | | IS PERMITTED UNDER THE GC ZONING? IF NOT, THEN A USE | | | TABLE IS NOT PERMITTED. NOTE: A DISCUSSION NEEDS TO | | | TAKE PLACE ON THE PXR AND SB USES RELATING TO THE | | | ADDITIONAL STANDARDS. | | | | | | 14) THE VACUUM EQUIPMENT NEEDS TO BE SCREENED BY AN | | | OPAQUE FENCE AND HEDGE FOR ITS FULL HEIGHT. | | | | | | 15) PROVIDE DETAILS (OR PHOTO) OF THE VACUUM STATION. | | | | | | 16) THE WAVE BICYCLE RACK IS NOT PERMITTED IN THE CITY. | | | STAFF WAS UNABLE TO LOCATE THE BICYCLE RACK LOCATION | | | FOR THE NEW BUILDING. PAD SIZE AND DIMENSIONS ARE | | | REQUIRED ON A DETAIL AS WELL AS ON THE PLAN. | | | | | | 17) THE RELOCATED BICYCLE RACK ON THE EXISTING SITE | | | NEEDS TO BE REPLACED WITH A CODE COMPLIANT MODEL AND | | | DETAILS PROVIDED. | | | | | | 18) PLEASE CONSIDER USING A PERVIOUS PAVEMENT | | | UNDERNEATH THE VACUUM AREA PARKING SPOTS. | | | |
|
|
| |