Plan Review Details - Project Z19090032
Plan Review Stops For Project Z19090032
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 11-12-2019 Cont ID  
Sent By rbrown Date 11-12-2019 Time 19:44 Rev Time 0.00
Received By rbrown Date 11-12-2019 Time 19:44 Sent To  
Notes
2019-11-12 19:51:29DEVELOPMENT SERVICES DEPARTMENT, BUILDING DIVISION,
 COMMENTS:
  
 1. THIS REVIEW IS A CURSORY REVIEW AS IT RELATES TO THE
 SITE. IT IS NOT A REVIEW FOR FULL COMPLIANCE WITH
 FLORIDA BUILDING CODE. THE FOLLOWING COMMENTS ARE TO BE
 ADDRESSED FOR THE BUILDING PERMIT APPLICATION.
  
 2. RENOVATION OF THE EXISTING BUILDING. AN ASBESTOS
 SURVEY SHALL BE PERFORMED AND AN ASBESTOS ABATEMENT
 REPORT SUBMITTED TO THE HEALTH DEPARTMENT PALM BEACH
 COUNTY OFFICE. CONTACT ALEX ORTEGA AT (561) 837-5963,
 OR BY EMAIL: [email protected]
  
 3. BUILDING SIZE. WHEN SUBMITTED FOR BUILDING PERMIT,
 THE PLANS SHALL SHOW THAT THE TYPE OF CONSTRUCTION FOR
 THE BUILDINGS WILL BE IN ACCORDANCE WITH THE HEIGHT,
 AREA AND OCCUPANCY LIMITATIONS IN CHAPTER 5 OF THE
 FLORIDA BUILDING CODE.
  
 4. THE ADDITION TO THE EXISTING BUILDING IS COVERED BY
 CHAPTER 11 OF THE FLORIDA EXISTING BUILDING CODE. THE
 HEIGHT AND/OR AREA INCREASE DUE TO THE PROPOSED
 ADDITION SHALL NOT INCREASE THE TOTAL BUILDING HEIGHT
 AND/OR AREA BEYOND THAT ALLOWED UNDER THE APPLICABLE
 PROVISIONS OF CHAPTER 5 OF THE FLORIDA BUILDING CODE
 FOR THE TYPE OF CONSTRUCTION USED.
  
 5. GREASE INTERCEPTOR. A GREASE INTERCEPTOR WILL BE
 REQUIRED FOR THE COMMERCIAL KITCHEN. PLEASE CONTACT
 JEFFREY ODOMS, UTILITIES O&M SUPERINTENDENT, PUBLIC
 UTILITIES DEPARTMENT, FATS OILS AND GREASE DIVISION, AT
 (561) 822-2172, OR BY EMAIL: [email protected]
  
 6. SEPARATE PERMITS REQUIRED. ALL APPLICABLE PERMITS
 AND SUB-PERMITS MUST BE OBTAINED BEFORE COMMENCING THE
 WORK. SEPARATE PERMITS, PLANS AND FEES, ARE REQUIRED
 FOR SIGNS, SWIMMING POOLS AND SPAS, GAS SYSTEMS,
 GENERATORS, FIRE ALARM SYSTEMS, FIRE SPRINKLER AND
 OTHER FIRE SUPPRESSION SYSTEMS, GREASE INTERCEPTORS,
 SITE LIGHTING, SITE LANDSCAPE, SITE IRRIGATION, ETC.
  
 7. CONTRACTOR VEHICLE PARKING. PROPERTY OWNER AND
 CONTRACTOR SHALL MAKE ARRANGEMENTS FOR PARKING OF
 CONTRACTOR VEHICLES TO MINIMIZE THE IMPACT ON ALL
 NEIGHBORING PROPERTIES.
  
 8. PROTECTION OF NEIGHBORING PROPERTY. PROPERTY OWNER
 AND CONTRACTOR SHALL PROTECT ALL NEIGHBORING PROPERTY,
 INCLUDING VEHICLES, FROM DAMAGE OR DIRT CAUSED BY THE
 CONSTRUCTION, AND SHALL NOTIFY THE OCCUPANTS OF
 NEIGHBORING PROPERTIES ABOUT ALL STAGES OF CONSTRUCTION
 THAT MAY AFFECT THE USE OF THEIR PROPERTY.
  
 ROBERT BROWN
 BUILDING OFFICIAL
 TEL: 561 805 6652
 EMAIL: [email protected]
  

Review Stop ENG - PPRC ENGINEERING - PPRC
Rev No 3 Status F Date 09-24-2021 Cont ID  
Sent By RROSSANO Date 09-24-2021 Time   Rev Time 0.00
Received By rrossano Date 09-24-2021 Time   Sent To  
Notes
2021-09-24 08:25:02COMMENTS FROM RICK ROSSANO, PROJECT COORDINATOR, ENG.
 SERVICES DEPT., 561-494-1098 [email protected] :
  
 1. CONFIRM THAT A COMPLETED LOS ANALYSIS SUMMARY TABLE
 HAS BEEN SUBMITTED DIRECTLY TO ENGINEERING (SHEET 33 OF
 CITY OF WPB DEVELOPMENT APPLICATION).
 2. CHECK TO SEE IF FDEP FORMS FOR PROPOSED SANITARY
 SEWER ARE REQUIRED.
 3. COORDINATE WITH MARK HURLEY, FIELD CUSTOMER SERVICE
 SUPERVISOR WITH CITY OF WPB PUBLIC UTILITIES, REGARDING
 PLACEMENT OF BACKFLOW DEVICES AND WATER METERS. CONTACT
 HIM AT 561-494-2262 OR [email protected]
 4. FOR FORMAL ENGINEERING SUBMITTAL , PLANS SHALL SHOW
 PROPOSED LOCATIONS AND DIMENSIONS OF ALL WATER,
 STORMWATER, AND SANITARY AND SEWER LINES, INCLUDING
 STUBS TO EACH PROPERTY LINE FOR WATER AND SANITARY
 SEWERS, THE MAKE AND MODEL OF ALL VALVES, METERS, AND
 OTHERS DEVICES TO BE INSTALLED ON THE SYSTEM, CATCH
 BASINS, CULVERTS, DITCHES INCLUDING GRADES, PIPES
 SIZES, MATERIALS, ELEVATIONS, ASSUMPTIONS,
 CALCULATIONS, INVERT ELEVATIONS FOR ALL INLETS AND
 MANHOLES AND PROFILES OF SANITARY SEWER LINES. ALL
 AVAILABLE ELEVATION SHALL BE SHOWN ON THE PROFILE VIEW.
 DIRECTION OF FLOW SHALL BE SHOWN ON PLAN VIEW ON PLAN
 VIEW FOR ALL SANITARY AND STORM SEWERS. ADDITIONALLY,
 PLAN VIEW SHALL SHOW ALL EXISTING AND PROPOSED
 UNDERGROUND UTILITY LAYOUT, INCLUDING FIBER OPTIC,
 ELECTRIC, GAS, AND CABLEVISION & TELECOMMUNICATION
 FACILITIES LOCATED ON THE RIGHT-OF-WAY.
 5. FOR FORMAL ENGINEERING SUBMITTAL, PLEASE PROVIDE
 ENLARGED VIEW ON PLANS OF PROPOSED LOCATION OF WATER
 METER AND BACKFLOW PREVENTION.
 6. FOR FORMAL ENGINEERING SUBMITTAL, PLEASE CALLOUT
 DOMESTIC BACKFLOW PREVENTER AS RPPA AND FIRE BACKFLOW
 PREVENTER AS DCDA. SPECIFY LEAD FREE DESIGN ON ALL
 BACKFLOWS.
 7. FOR FORMAL ENGINEERING SUBMITTAL, SFWMD ERP AND
 NPDES NOI REQUIREMENTS WILL BE ENFORCED.
 - AN NOI IS REQUIRED FOR PROJECTS THAT:
 - 1) DISTURB ONE OF MORE ACRES OF LAND OR DISTURB LESS
 THAN ON ACRE OF LAND BUT ARE PART OF A COMMON PLAN OF
 DEVELOPMENT OR SALE; AND
 - 2) DISCHARGE STORMWATER TO SURFACE WATERS OF THE
 STATE OR TO SURFACE WATERS OF THE STATE THROUGH A
 MUNICIPAL SEPARATE STORM SEWER SYSTEM (MS4).
 - THE SFWMD ERP CAN BE OBTAINED THROUGH A 10-2 SELF
 CERTIFICATION THROUGH FDEP OR AN ERP APPLICATION
 THROUGH SFWMD. EITHER WAY, THE DEVELOPER/ENGINEER SHALL
 SUBMIT A COPY OF THE ERP PERMIT OR FDEP ACKNOWLEDGEMENT
 OF THE 10-2 CERTIFICATION. IF THE ENGINEERING PLANS DO
 NOT INCLUDE AN EROSION CONTROL PLAN, THEN THE
 CONTRACTOR SHOULD SUBMIT ONE PRIOR TO RECEIVING THE
 ENGINEERING PERMIT.
 8. FOR FORMAL ENGINEERING SUBMITTAL, PROVIDE PROFILES
 OF PROPOSED AND EXISTING WATER AND SEWER WITHIN RIGHT
 OF WAY AND SHOW ANY CROSSINGS/CONFLICTS.
 9. FOR FORMAL ENGINEERING SUBMITTAL, WHEN SUBMITTING
 APPROVED MATERIALS LIST, PLEASE PROVIDE MATERIAL/CUT
 SHEETS FOR ALL PROPOSED BACKFLOW DEVICES SHOWING
 SPECIFIC MODEL NUMBER AND SPECIFYING USC APPROVED
 LEAD-FREE DESIGN.
 10. FOR FORMAL ENGINEERING SUBMITTAL, WHEN TRENCHING IN
 IN CITY MAINTAINED ROADWAY AREAS ADD NOTE TO PROVIDE 50
 FT. PAVEMENT RESTORATION TRANSITION ON EACH SIDE OF
 PROPOSED TRENCH PER CURRENT CITY OF WPB STANDARD DETAIL
 GC-8.
 11. PLEASE RESPOND TO ALL COMMENTS IN WRITING AND
 INCLUDE PROJECT NAME, ADDRESS AND PERMIT NUMBER
 (Z-XXXXXXXX).
  
 COMMENTS FROM MARK HURLEY, FIELD CUSTOMER SERVICE
 SUPER., WPB PUBLIC UTILITIES, 561-494-2262 OR
 [email protected]:
  
 -THERE ARE A COUPLE BIKE RACKS PROPOSED OVER PLUMBING
 OR DRAIN PIPE. MAY MAKE MAINTENANCE OF PIPE MORE
 DIFFICULT.
 -WILL THE GYMNASIUM BUILDING GET POTABLE WATER FROM
 PLUMBING CONNECTION TO EXISTING BUILDING, OR A NEW
 METERED WATER SERVICE?
 -FOR FORMAL ENGINEERING SUBMITTAL UPDATE WATER PLANS AS
 FOLLOWS: CALLOUT DISTANCE BETWEEN UTILITY POLE AND
 SEWER LATERAL NEAR SOUTHWEST CORNER OF PROPERTY,
 CALLOUT DISTANCE BETWEEN 4 BY 4 FIRE TEE AND LIGHT
 POLE, SHOW FIRE FLOW CALCULATIONS, LABEL PIPING BETWEEN
 WATER MAIN AND DCDA AS DIP, ADD GATE VALVE UPSTREAM OF
 DCDA BETWEEN SIDEWALK AND PROPERTY LINE AND LABEL AS
 POINT OF SERVICE.
  
 -SEWER LATERALS IN OUR SERVICE AREA ARE TYPICALLY 6
 INCH MINIMUM. PLEASE REVIEW AND UPDATE AS NEEDED AT
 FORMAL ENGINEERING SUBMITTAL.
  
 COMMENTS FROM MICHAEL TECHNOW, PROJECT ENGINEER, WPB
 PUBLIC UTILITIES, 561-494-1047, [email protected] :
  
 -PLEASE SHOW PROFILE AT TAP AND POINT OF SERVICE.
 -ADD NOTE THIS IS WITH LS #21 SERVICE BOUNDARY.
 -ADD EXISTING DRY UTILITIES.
 -CALL OUR DIMENSIONS FOR EASEMENT.
 -SHOW DETAIL FOR DCDA (CITY?S)
 -SHOW EXISTING VALVES (IF ANY).
 -SHOW EXISTING SEWER LATERALS AND WATER SERVICES
 CURRENTLY SERVING PROPERTY. IF NOT IN USE, CUT AND CAP
 AT THE MAIN.
 -CALL OUT TYPICAL UTILITY CROSSING WITH VERTICAL
 CLEARANCE.
 -MAKE NOTE ON MH ON 21ST ST. ?ADJUST TO FINISHED GRADE
 AS REQUIRED?
 -PROVIDE CCTV OF NEW SEWER LATERALS.
 -WHAT IS THE DASHED LINE (CIRCLE ON 19TH ST)?
 -SHOW EXISTING WATER/SEWER SERVICES ON 19TH ST. AND
 PROPOSED IMPROVEMENTS.
 -FOR THE 18? VCP SWM ADD NOTE TO REHAB AS REQUIRED.
  

Review Stop ENG - PPRC ENGINEERING - PPRC
Rev No 2 Status F Date 06-14-2021 Cont ID  
Sent By rrossano Date 06-14-2021 Time   Rev Time 0.00
Received By rrossano Date 06-14-2021 Time   Sent To  
Notes
2021-07-01 08:33:59PERVIOUS/IMPERVIOUS CALCULATIONS TO BE SHOWN ON
 ENGINEERING PLANS.
 PLEASE SHOW WATER (INCL. FIRE AND IRRIGATION) AND
 SANITARY DEMANDS TO SHEET 4 OF SITE PLAN SUBMITTAL.
 PLEASE ADD INLET PROTECTION (FILTER FABRIC) TO ALL
 NEARBY DRAINAGE STRUCTURES.
 PLEASE CONFIRM ALL CITY OF WPB STANDARD DETAILS ARE
 MOST CURRENT VERSIONS. CONTACT JANICE TARBILL AT
 [email protected] FOR CAD FORMAT VERSION.
 PLEASE PROVIDE CCTV OF EXISTING SANITARY PIPE ON 19TH
 ST. LABEL EXISTING PIPE MATERIAL AND SIZE.
 PLEASE SHOW PAVEMENT RESTORATION (50 FT. EACH SIDE OF
 TAP) AT SCALE PER CIT OF WPB STANDARD DETAIL GC-8.
  
  
 COMMENTS PER MARK HURLEY FIELD CUSTOMER SERVICE
 SUPERVISOR, CITY OF WEST PALM BEACH PUBLIC UTILITIES
 561-822-2262 [email protected]
  
 -ON WATER AND DEMO PLANS, SHOW ALL EXISTING AND
 PROPOSED UTILITY INFRASTRUCTURE. APPEARS LARGE SEWER
 MAIN ALONG WEST SIDE OF PROPERTY IS MISSING AS WELL AS
 SEWER LATERAL ON NORTH SIDE OF PROPERTY FOR THE
 EXISTING BUILDING.
  
 -SHOW AND LABEL EXISTING DOMESTIC METER AND BACKFLOW
 ASSEMBLY ON NORTH SIDE OF PROPERTY WEST OF WEST
 DRIVEWAY.
  
 -FOR FORMAL ENGINEERING SUBMITTAL: 1) PROVIDE SEPARATE
 BLOWUP DETAIL OF AREA AROUND DCDA. 2) LABEL ALL
 PROPOSED PIPE WITH SIZE AND MATERIAL TYPE. 3) ADD INV
 ELEVATION INFO TO LABELS OF SANITARY MANHOLES ON 19TH
 ST. 4) LABEL ALL EXISTING WATER AND SEWER MAINS WITH
 PIPE SIZE AND MATERIAL TYPE. 5) ADD GATE VALVE UPSTREAM
 OF DCDA BEFORE METER TAP SO FIRELINE CAN BE SHUT OFF
 WITHOUT AFFECTING THE OTHER WATER METER. 6) ADD SIZE OF
 PROPOSED BACKFLOW ASSEMBLIES TO LABELS. 7) LABEL
 EXISTING WATER SERVICES WITH PIPE SIZE AND MATERIAL
 TYPE. 8) SHOW ALL EXISTING WATER MAIN VALVES IN
 STREETS.
  
 -SANITARY MANHOLE APPEARS TO BE MISSING FROM WATER PLAN
 NEAR NW AREA OF PROPERTY. PLEASE ADD.
  
 -SEWER LATERAL SHOWS ALL WASTEWATER FLOWING THROUGH
 GREASE TRAP. IS THAT CORRECT?
  
 -VERIFY WHAT EXISTING WATER PIPE AT PROPOSED LOCATION
 OF GYMNASIUM FEEDS. ALSO ADD LABEL DESCRIBING WHAT IS
 HAPPENING TO IT ON WATER AND DEMO PLANS.
  
 -LABEL THE EXISTING IRRIGATION WATER SERVICE.
  
 -ADD WATER DEMAND CALCULATIONS TO WATER PLAN.
  
 -WILL THE FIRELINE JUST FEED THE NEW BUILDING OR ALSO
 THE EXISTING BUILDING?
  
 -REVIEW ANY PROPOSED TREES ON SIDES OF PROPERTY TO
 ENSURE NO CONFLICTS WITH EXISTING AND PROPOSED WATER
 SERVICES AND SEWER LATERALS. INCREASE CLEARANCE
 DISTANCES AND ADD ROOT BARRIERS AS NEEDED.
  
 -SHOW AND LABEL FIRE HYDRANT NEAR NE AREA OF PROPERTY.
  

Review Stop ENG - PPRC ENGINEERING - PPRC
Rev No 1 Status F Date 11-08-2019 Cont ID  
Sent By rrossano Date 11-08-2019 Time   Rev Time 3.00
Received By rrossano Date 11-08-2019 Time   Sent To  
Notes
2019-11-08 10:36:231. PLEASE RESPOND IN WRITING TO ALL COMMENTS WITH Z
 PERMIT NUMBER, PROJECT NAME AND ADDRESS.
 2. PLANS SHALL SHOW PROPOSED LOCATIONS AND DIMENSIONS
 OF ALL WATER, STORMWATER, AND SANITARY AND SEWER LINES,
 INCLUDING STUBS TO EACH PROPERTY LINE FOR WATER AND
 SANITARY SEWERS, THE MAKE AND MODEL OF ALL VALVES,
 METERS, AND OTHERS DEVICES TO BE INSTALLED ON THE
 SYSTEM, CATCH BASINS, CULVERTS, DITCHES INCLUDING
 GRADES, PIPES SIZES, MATERIALS, ELEVATIONS,
 ASSUMPTIONS, CALCULATIONS, INVERT ELEVATIONS FOR ALL
 INLETS AND MANHOLES AND PROFILES OF SANITARY SEWER
 LINES. ALL AVAILABLE ELEVATION SHALL BE SHOWN ON THE
 PROFILE VIEW. DIRECTION OF FLOW SHALL BE SHOWN ON PLAN
 VIEW ON PLAN VIEW FOR ALL SANITARY AND STORM SEWERS.
 PLEASE SHOW SLOPE % ON ALL SANITARY LINES AND CALL OUT
 MATERIAL. ADDITIONALLY, PLAN VIEW SHALL SHOW ALL
 EXISTING AND PROPOSED UNDERGROUND UTILITY LAYOUT,
 INCLUDING FIBER OPTIC, ELECTRIC, GAS, AND CABLEVISION &
 TELECOMMUNICATION FACILITIES LOCATED ON THE
 RIGHT-OF-WAY. PROVIDE PROFILE AND CLEARANCES AT ALL
 UTILITY CROSSINGS.
 3. CUT AND CAP UTILITIES NOT IN USE, AND REMOVE ANY
 ABANDONED UTILITY LINES LARGER THAN 2 INCHES FROM CITY
 RIGHT OF WAY.
 4. PLEASE SUBMIT COMPLETED LOS ANALYSIS SUMMARY TABLE
 DIRECTLY TO ENGINEERING (SHEET 33 OF CITY OF WPB
 DEVELOPMENT APPLICATION).
 5. PROVIDE CALCULATIONS ON PLANS OF EXISTING AND
 PROPOSED DEMANDS FOR WATER & SEWER (AVERAGE, MAXIMUM
 AND PEAK) AND FIRE FLOW DEMANDS. CALCULATIONS SHALL BE
 PER FAC 64E-6 FOR SEWER AND PER FAC 64-E.008 FOR WATER.
 6. SHOW VERTICAL DATUM AND DATUM CONVERSION INFORMATION
 (NAVD 88 AND NGVD 29).
 7. PLEASE PROVIDE CALCULATIONS OF REVISED PERVIOUS AND
 IMPERVIOUS CALCULATIONS FOR THE PROPOSED IMPACTED
 AREAS.
 8. PLEASE RELOCATE ONSITE CLEANOUTS CLOSER TO PROPERTY
 LINE FOR PROPOSED SANITARY LATERALS.
 9. COORDINATE WITH MARK HURLEY, FIELD CUSTOMER SERVICE
 SUPERVISOR WITH CITY OF WPB PUBLIC UTILITIES, REGARDING
 PLACEMENT OF BACKFLOW DEVICES AND WATER METERS. CONTACT
 HIM AT 561-494-2262 OR [email protected]
 10. PLEASE CHECK TO SEE IF FDEP FORMS ARE NEEDED.
 11. PLEASE CLEARLY LABEL CITY OF WPB POINTS OF SERVICE
 FOR UTILITY CONNECTIONS.
 12. FOR FORMAL ENGINEERING SUBMITTAL, PLEASE PROVIDE
 ENLARGED VIEW ON PLANS OF PROPOSED LOCATION OF WATER
 METER AND BACKFLOW PREVENTION. INCLUDE EASEMENT
 DEDICATION FOR WATER METER.
 13. FOR FORMAL ENGINEERING SUBMITTAL, PLEASE CALLOUT
 DOMESTIC BACKFLOW PREVENTER AS RPPA AND FIRE BACKFLOW
 PREVENTER AS DCDA. SPECIFY LEAD FREE DESIGN ON ALL
 BACKFLOWS.
 14. FOR FORMAL ENGINEERING SUBMITTAL, PROVIDE PROFILES
 OF WATER AND SEWER AND SHOW ANY CROSSINGS/CONFLICTS.
 15. FOR FORMAL ENGINEERING SUBMITTAL, WHEN SUBMITTING
 APPROVED MATERIALS LIST, PLEASE PROVIDE MATERIAL/CUT
 SHEETS FOR ALL PROPOSED BACKFLOW DEVICES SHOWING
 SPECIFIC MODEL NUMBER AND SPECIFYING USC APPROVED
 LEAD-FREE DESIGN.
 16. ON CIVIL PLANS COVER SHEET, PLEASE UPDATE MAYOR?S
 NAME, ADD PROJECT ADDRESS.
 17. CIVIL PLANS ARE FUZZY, ELEVATIONS ARE DIFFICULT TO
 READ.
  
 SHEET C-04:
 - PLEASE LABEL ROAD (EAST PARKWAY?).
 - CLEARLY INDICATE RIGHTS OF WAY.
 - ADD PAVEMENT RESTORATION NOTE PER CITY OF WPB
 STANDARD DETAIL GC-9; CALLOUT LIMITS OF PAVEMENT
 RESTORATION.
 - SHOW LATERAL CLEARANCE BETWEEN EXISTING ONSITE
 DRAINAGE LINE AND PROPOSED WATER LINE PER CITY OF WPB
 STANDARD DETAIL GN-2.
 - CLEARLY SHOW ONSITE WATER LAYOUT, SPECIFY MATERIAL,
 SIZES ETC.
  
 FEEL FREE TO CONTACT US IF YOU HAVE ANY QUESTIONS OR
 CONCERNS, THANKS.
  
 RICK ROSSANO, PROJECT COORDINATOR
 ENGINEERING SERVICES DEPARTMENT
 DIRECT: (561) 494-1098
 [email protected]
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 06-22-2021 Cont ID  
Sent By pleduc Date 06-22-2021 Time   Rev Time 0.00
Received By pleduc Date 06-22-2021 Time 11:54 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 11-06-2019 Cont ID  
Sent By pleduc Date 11-06-2019 Time   Rev Time 0.00
Received By pleduc Date 11-06-2019 Time 13:03 Sent To  
Notes
2019-11-06 13:06:44THE FOLLOWING COMMENTS WERE SUBMITTED BY PETER LEDUC,
 FIRE MARSHAL, BUREAU OF FIRE PREVENTION, WEST PALM
 BEACH FIRE RESCUE.
  
 THIS REVIEW CAN ONLY BE CONSIDERED PRELIMINARY AS THE
 DRAWINGS THAT WERE REVIEWED WERE NOT COMPLETE.
 ADDITIONAL COMMENTS CAN BE EXPECTED WHEN FULL DRAWINGS
 ARE SUBMITTED FOR PERMIT.
  
 THE FIRE PREVENTION BUREAU HAS NO OBJECTIONS TO THE
 PROPOSED PROJECT.
  
 1. CONSTRUCTION, DEMOLITION, AND RENOVATION TO COMPLY
 WITH NFPA 241. EXTRA ATTENTION SHALL BE GIVEN TO THE
 PERMITTING AND LOCATION OF CONSTRUCTION TRAILERS. A
 PERMIT IS REQUIRED FOR ANY CONSTRUCTION TRAILER RELATED
 TO THIS PROJECT. SEPARATION DISTANCES FROM MAIN
 STRUCTURES AS WELL AS OTHER TRAILERS SHALL BE CLOSELY
 MONITORED FOR THE REQUIREMENTS OF FIRE SPRINKLER
 PROTECTION.
  
 2. SITE ACCESS AND EXIT POINTS ARE TO BE CLEARLY
 IDENTIFIED AND MAINTAINED FOR EMERGENCY VEHICLES DURING
 ALL CONSTRUCTION ACTIVITIES.
  
 3. THE BUILDING ADDRESS SHALL BE CLEARLY VISIBLE FROM
 ALL ACCESS ROADWAYS, INCLUDING DURING CONSTRUCTION.
 ADDRESS NUMBERS SHALL CONTRAST WITH THEIR BACKGROUND
 AND SHALL NOT BE LESS THAN SIX (6) INCHES IN HEIGHT
 WITH A ONE (1) INCH STROKE FOR ALL BUILDINGS.
  
 4. DURING CONSTRUCTION, TRASH AND DEBRIS IS TO BE
 REMOVED FROM THE SITE DAILY OR MORE OFTEN TO REDUCE THE
 ACCUMULATION OF POTENTIAL LIFE AND FIRE SAFETY HAZARDS.
  
 5. THE CONSTRUCTION OF THE BUILDING SHALL COMPLY WITH
 THE 6TH EDITION OF THE FLORIDA FIRE PREVENTION CODE,
 INCLUDING NFPA 1 & 101, AND ALL ASSOCIATED FIRE CODES.
  
 6. FOR PLAN REVIEW SUBMITTAL, PLEASE INCLUDE THE
 OCCUPANCY TYPE, PER THE FLORIDA FIRE PREVENTION CODE,
 AND WHETHER IT IS MIXED OR SEPARATED OCCUPANCY.
  
 7. FOR PLAN REVIEW SUBMITTAL, PLEASE ENSURE THAT A FIRE
 LOAD CALCULATION IS INCLUDED AND THAT ADEQUATE WATER
 SUPPLY IS EXISTING OR WILL BE PROVIDED.
  
 8. ALL EXISTING AND NEW FIRE HYDRANTS PLANNED FOR THIS
 DEVELOPMENT SHALL BE CLEARLY INDICATED AND IDENTIFIED
 ON THE PLAN AND CLOSELY COORDINATED WITH THE BUREAU OF
 FIRE PREVENTION.
  
 ALL NEW FIRE HYDRANTS AND FDC?S PLANNED FOR THIS
 DEVELOPMENT SHALL BE CLOSELY COORDINATED WITH THE
 BUREAU OF FIRE PREVENTION. PROPOSED FIRE HYDRANTS AND
 FDC?S SHOULD BE LOCATED ON THE SAME SIDE OF THE STREET
 OR ACCESS ROADWAY TO ALLOW FREE ACCESS FOR OTHER
 ARRIVING EMERGENCY VEHICLES.
  
 9. THE GYM IS AN ASSEMBLY OCCUPANCY AND BASED ON THE
 OCCUPANCY LOAD A FIRE SPRINKLER SYSTEM MAY BE REQUIRED.
 PER NFPA 101, CH 12 - 12.3.5.2 ANY BUILDING CONTAINING
 ONE OR MORE ASSEMBLY OCCUPANCIES WHERE THE AGGREGATE
 OCCUPANT LOAD OF THE ASSEMBLY OCCUPANCIES EXCEEDS 300
 SHALL BE PROTECTED BY AN APPROVED, SUPERVISED AUTOMATIC
 SPRINKLER SYSTEM IN ACCORDANCE WITH SECTION 9.7 AS
 FOLLOWS (SEE ALSO 12.1.6, 12.2.6, 12.3.2, AND 12.3.6):
 (1) THROUGHOUT THE STORY CONTAINING THE ASSEMBLY
 OCCUPANCY
 (2) THROUGHOUT ALL STORIES BELOW THE STORY CONTAINING
 THE ASSEMBLY OCCUPANCY
 (3) IN THE CASE OF AN ASSEMBLY OCCUPANCY LOCATED BELOW
 THE LEVEL OF EXIT DISCHARGE, THROUGHOUT ALL STORIES
 INTERVENING BETWEEN THAT STORY AND THE LEVEL OF EXIT
 DISCHARGE, INCLUDING THE LEVEL OF EXIT DISCHARGE
  
 PROVIDE FOR A FIRE SPRINKLER AND/OR FIRE ALARM PER THE
 APPLICABLE OCCUPANCY CODE. FOR ANY LIFE SAFETY
 ENGINEERED SYSTEM, I.E FIRE SPRINKLER AND FIRE ALARM,
 ENSURE THEY COMPLY WITH THE REQUIREMENTS OF FS 61G AND
 SUBMITTED WITH THE MASTER PLAN.
  
 10. COMPLETE LIFE SAFETY PLANS FOR EACH OCCUPANCY SHALL
 BE PROVIDED THAT ILLUSTRATE OCCUPANT LOADS, TRAVEL
 DISTANCES, COMMON PATHS OF TRAVEL, DEAD-END CORRIDORS,
 EXIT SIGNS, EMERGENCY LIGHTING, EXITS LEADING TO A
 PUBLIC WAY, FIRE EXTINGUISHER LOCATIONS, AND ALL FIRE
 SAFETY FEATURES AND EQUIPMENT.
  
 11. IT IS HIGHLY RECOMMENDED (REQUIRED WITH FIRE
 SPRINKLER SYSTEM) THAT A KNOX BOX WITH KEYS FOR ENTRY
 DOOR LOCKS BE PROVIDED FOR 24 HOUR EMERGENCY ACCESS.
  
 12. THE BUREAU'S APPROVAL OF THIS SUBMITTED PROJECT
 DOES NOT CONSTITUTE ITS FINAL REVIEW OR APPROVAL.
  
 13. THE BUREAU SHALL REVIEW ALL SUBMITTED BUILDING
 PLANS AT THE APPROPRIATE TIME AND IN ACCORDANCE WITH
 THE REQUIREMENTS OF ALL APPLICABLE CODES AND STANDARDS.
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]
  

Review Stop L LANDSCAPING
Rev No 3 Status P Date 10-01-2021 Cont ID  
Sent By rcaranci Date 10-01-2021 Time 14:26 Rev Time 0.00
Received By rcaranci Date 10-01-2021 Time 14:26 Sent To  
Notes
2021-10-01 14:28:49FROM: RAY CARANCI, LANDSCAPE PLANNER 561-822-1462
 PROJECT: COLEMAN PARK COMMUNITY CENTER Z19090032
 OCTOBER 1, 2021
  
 ANDREW BURNETT LANDSCAPE PLANNER 6/17/21
 561-822-1562
  
 1. SATISFIED. PROVIDE A TREE SURVEY, TREE DISPOSITION
 PLAN AND CHART FOR EXISTING TREES IN THE AFFECTED AREA.
 A. MULTIPLE LIVE OAK TREES LISTED AS REMOVAL ON TREE
 SURVEY.
 PER CODE 94-448 D. 3. A-C TREE RELOCATION AND
 REPLACEMENT. THE APPLICANT FOR A TREE REMOVAL PERMIT
 SHALL BE REQUIRED TO RELOCATE OR REPLACE TREES TO BE
 REMOVED OR PROVIDE PAYMENT IN LIEU THEREOF INTO THE
 LANDSCAPE TRUST ACCOUNT FOR TREES THAT CANNOT BE
 RELOCATED, REPLACED OR INSTALLED DUE TO PREEXISTING
 SITE DEVELOPMENT CONSTRAINTS AS DETERMINED BY THE
 PLANNING AND ZONING ADMINISTRATOR. NATIVE TREES AND
 PALMS IN GOOD CONDITION MUST BE PRESERVED ON SITE OR
 RELOCATED. RELOCATED TREES SHALL BE INSTALLED IN A
 SOUND AND SKILLED MANNER ACCORDING TO ACCEPTED PLANTING
 PRACTICES AND SHALL BE IN ACCORDANCE WITH THE
 FOLLOWING:
 A. IF THE TREE IS TRANSPLANTED, IT SHALL BE MOVED BY
 THE PROPERTY OWNER IN ACCORDANCE WITH THE NATIONAL
 ARBORIST ASSOCIATION STANDARDS OR OTHER PROFESSIONAL
 ARBORIST ASSOCIATION, CURRENTLY THE ANSI A-300
 STANDARDS, TO ANOTHER LOCATION WITHIN THE CITY AND
 MAINTAINED BY THE NEW PROPERTY OWNER.
 B. IF A TREE ON PUBLIC PROPERTY IS WILLFULLY DESTROYED
 BY ANYONE EXCEPT THE CITY FORESTER/ARBORIST, THE TREE
 MUST BE SUBSTITUTED WITH AN EQUIVALENT REPLACEMENT THAT
 IS APPROVED BY THE FORESTER/ARBORIST OR DESIGNER ON THE
 SITE FROM WHICH THE DESTROYED TREE WAS REMOVED.
 C. NO PERMIT SHALL BE REQUIRED FOR THE REMOVAL OF TREES
 THAT ARE DEAD, SEVERELY DISEASED, ARE INVASIVE EXOTIC
 SPECIES, OR ARE DESTROYED BY NATURAL CAUSES. THIS
 INCLUDES TREES THAT ARE PLANTED IN A CERTIFIED NURSERY
 OR BOTANICAL GARDEN.
  
  
 2. SATISFIED. PROVIDE A LANDSCAPE PLAN MEETING CITY
 CODE AND POLICY REQUIREMENTS. FOR ALL CITY PROJECT USE
 OF LOW MAINTENANCE NATIVE PLANTS IS PREFERRED BY CITY
 POLICY.
 CONDITIONS OF APPROVAL
  
 3. SATISFIED. LANDSCAPE HEDGES NEED TO BE PLANTED TO
 SCREEN MECHANICAL EQUIPMENT, AC UNITS, FPL BOX WATER
 BACKFLOWS , WATER METERS. ON 3 SIDES WITH THE EXCEPTION
 OF THE ACCESS DOOR SIDE.
  
 CONDITIONS OF APPROVAL
 1. PRIOR TO THE REMOVAL OR RELOCATION OF ANY TREES ON
 THE PROPERTY, A TREE ALTERATION PERMIT SHALL BE
 SUBMITTED, REVIEWED AND APPROVED BY THE DEVELOPMENT
 SERVICES DEPARTMENT, PLANNING DIVISION.
  
 2. PRIOR TO SUBMITTAL OF THE TREE ALTERATION PERMIT AND
 THE LANDSCAPE PERMIT, THE APPLICANT SHALL MAKE THE
 FOLLOWING CORRECTIONS TO THE EXISTING TREE PLAN SHEET 1
 OF 2 AND THE LANDSCAPE PLAN:
 ? SABAL PALMS ARE CATEGORY 3, SO MITIGATION CREDIT IS
 100 SQ FT. EACH ON THE MITIGATION CHART, NOT 200.
 ? WITH THIS CORRECTION,
 ADD TREE TREES OR PALMS TO THE LANDSCAPE PLAN FOR
 CANOPY CREDITS TO COVER THE 653 SQ FT MITIGATION DUE.
  
  

Review Stop L LANDSCAPING
Rev No 2 Status F Date 06-17-2021 Cont ID  
Sent By aburnett Date 06-17-2021 Time 16:17 Rev Time 0.00
Received By aburnett Date 06-17-2021 Time 16:17 Sent To  
Notes
2021-06-17 16:19:29ANDREW BURNETT LANDSCAPE PLANNER 6/17/21
 561-822-1562
  
 1. PROVIDE A TREE SURVEY, TREE DISPOSITION PLAN AND
 CHART FOR EXISTING TREES IN THE AFFECTED AREA.
  
 PARTIALLY SATISFIED
 A. MULTIPLE LIVE OAK TREES LISTED AS REMOVAL ON TREE
 SURVEY.
 PER CODE 94-448 D. 3. A-C TREE RELOCATION AND
 REPLACEMENT. THE APPLICANT FOR A TREE REMOVAL PERMIT
 SHALL BE REQUIRED TO RELOCATE OR REPLACE TREES TO BE
 REMOVED OR PROVIDE PAYMENT IN LIEU THEREOF INTO THE
 LANDSCAPE TRUST ACCOUNT FOR TREES THAT CANNOT BE
 RELOCATED, REPLACED OR INSTALLED DUE TO PREEXISTING
 SITE DEVELOPMENT CONSTRAINTS AS DETERMINED BY THE
 PLANNING AND ZONING ADMINISTRATOR. NATIVE TREES AND
 PALMS IN GOOD CONDITION MUST BE PRESERVED ON SITE OR
 RELOCATED. RELOCATED TREES SHALL BE INSTALLED IN A
 SOUND AND SKILLED MANNER ACCORDING TO ACCEPTED PLANTING
 PRACTICES AND SHALL BE IN ACCORDANCE WITH THE
 FOLLOWING:
 A. IF THE TREE IS TRANSPLANTED, IT SHALL BE MOVED BY
 THE PROPERTY OWNER IN ACCORDANCE WITH THE NATIONAL
 ARBORIST ASSOCIATION STANDARDS OR OTHER PROFESSIONAL
 ARBORIST ASSOCIATION, CURRENTLY THE ANSI A-300
 STANDARDS, TO ANOTHER LOCATION WITHIN THE CITY AND
 MAINTAINED BY THE NEW PROPERTY OWNER.
 B. IF A TREE ON PUBLIC PROPERTY IS WILLFULLY DESTROYED
 BY ANYONE EXCEPT THE CITY FORESTER/ARBORIST, THE TREE
 MUST BE SUBSTITUTED WITH AN EQUIVALENT REPLACEMENT THAT
 IS APPROVED BY THE FORESTER/ARBORIST OR DESIGNER ON THE
 SITE FROM WHICH THE DESTROYED TREE WAS REMOVED.
 C. NO PERMIT SHALL BE REQUIRED FOR THE REMOVAL OF TREES
 THAT ARE DEAD, SEVERELY DISEASED, ARE INVASIVE EXOTIC
 SPECIES, OR ARE DESTROYED BY NATURAL CAUSES. THIS
 INCLUDES TREES THAT ARE PLANTED IN A CERTIFIED NURSERY
 OR BOTANICAL GARDEN.
  
  
 2. PROVIDE A LANDSCAPE PLAN MEETING CITY CODE AND
 POLICY REQUIREMENTS. FOR ALL CITY PROJECT USE OF LOW
 MAINTENANCE NATIVE PLANTS IS PREFERRED BY CITY POLICY.
 A. PRIOR TO THE REMOVAL OR RELOCATION OF ANY TREES ON
 THE PROPERTY, A TREE ALTERATION PERMIT SHALL BE
 SUBMITTED, REVIEWED, AND APPROVED BY THE DEVELOPMENT
 SERVICES DEPARTMENTS, PLANNING DIVISION.
 PARTIALLY SATISFIED: TREE ALTERATION PERMIT NEEDED
  
 3. LANDSCAPE HEDGES NEED TO BE PLANTED TO SCREEN
 MECHANICAL EQUIPMENT, AC UNITS , FPL BOX WATER
 BACKFLOWS , WATER METERS. ON 3 SIDES WITH THE EXCEPTION
 OF THE ACCESS DOOR SIDE.
  

Review Stop L LANDSCAPING
Rev No 1 Status F Date 11-08-2019 Cont ID  
Sent By rcaranci Date 11-08-2019 Time 10:38 Rev Time 0.00
Received By rcaranci Date 11-08-2019 Time 10:38 Sent To  
Notes
2019-11-08 10:38:41FROM: RAY CARANCI, LANDSCAPE PLANNER 561-822-1462
 PROJECT: COLEMAN PARK COMMUNITY CENTER Z19090032
 NOVEMBER 8, 2019
 I HAVE REVIEWED THE ABOVE REFERENCED PETITION, AND
 PROVIDE THE FOLLOWING COMMENTS:
  
  
 1. PROVIDE A TREE SURVEY, TREE DISPOSITION PLAN AND
 CHART FOR EXISTING TREES IN THE AFFECTED AREA.
  
 2. PROVIDE A LANDSCAPE PLAN MEETING CITY CODE AND
 POLICY REQUIREMENTS.
 FOR ALL CITY PROJECTS USE OF LOW MAINTENANCE NATIVE
 PLANTS IS PREFERRED BY CITY POLICY.
  
  
 CONDITIONS OF APPROVAL
 1. PRIOR TO THE REMOVAL OR RELOCATION OF ANY TREES ON
 THE PROPERTY, A TREE ALTERATION PERMIT SHALL BE
 SUBMITTED, REVIEWED AND APPROVED BY THE DEVELOPMENT
 SERVICES DEPARTMENT, PLANNING DIVISION.
  

Review Stop PARK PARKING
Rev No 1 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time  
Received By   Date   Time   Sent To  
Notes
***NONE***

Review Stop POLICE POLICE
Rev No 1 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time  
Received By   Date   Time   Sent To  
Notes
***NONE***

Review Stop PW PUBLIC WORKS
Rev No 2 Status P Date 06-14-2021 Cont ID  
Sent By   Date 06-14-2021 Time   Rev Time 0.00
Received By   Date 06-14-2023 Time   Sent To  
Notes
2021-06-14 07:39:57NO FURTHER COMMENTS FROM DEPT. OF PUBLIC WORKS
  
 MATT HEJAZI
 [email protected]
  

Review Stop PW PUBLIC WORKS
Rev No 1 Status F Date 11-06-2019 Cont ID  
Sent By   Date 11-06-2019 Time   Rev Time  
Received By   Date 11-06-2019 Time   Sent To  
Notes
2019-11-06 14:29:57- PLEASE PROVIDE AUTO TURN FOR THE SANITATION SERVICE.
 - FOR A FREESTANDING SITE DUMPSTER ENCLOSURE, THE
 ENCLOSURE SHALL COMPLY WITH THE LATEST REVISION OF CITY
 OF WEST PALM BEACH GENERAL CONSTRUCTION-GARBAGE
 ENCLOSURE STANDARD, CG-8.
  
  
 MATT HEJAZI
 DEPT. OF PUBLIC WORKS
 [email protected]
 561-822-2045

Review Stop STORM STORMWATER
Rev No 2 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time 0.00
Received By   Date   Time   Sent To  
Notes
***NONE***

Review Stop STORM STORMWATER
Rev No 1 Status F Date 11-13-2019 Cont ID  
Sent By tward Date 11-13-2019 Time 09:39 Rev Time 0.00
Received By tward Date 11-13-2019 Time 09:39 Sent To  
Notes
2019-11-13 09:39:00THIS IS A CONCEPTUAL LEVEL REVIEW. CONSTRUCTION LEVEL
 DETAILS, DESIGN CALCULATIONS AND THE POLLUTION
 PREVENTION PLAN WILL BE REVIEWED AS PART OF THE
 ENGINEERING DEVELOPMENT APPROVAL AND BUILDING PERMIT
 APPLICATION PROCESSES. THE ENGINEERING DEVELOPMENT
 APPROVAL APPLICATION FORMS CAN BE DOWNLOADED AT
  
 HTTPS://WPB.ORG/DEPARTMENTS/ENGINEERING-PUBLIC-WORKS/FO
 RMS,-PERMITS-APPLICATIONS
  
 THE FOLLOWING COMMENTS MUST BE ADDRESSED PRIOR TO SITE
 PLAN APPROVAL:
  
 1. OBTAIN INVERT ELEVATIONS OF EXISTING SANITARY AND
 DRAINAGE STRUCTURES.
  
 2. SHOW MILL AND RESURFACING LIMITS FOR TRENCH CUTS
 WITHIN THE RIGHT-OF-WAY. SEE CITY DETAILS.
  
 3. CAN SEWER LATERAL CONNECTION BE MADE WITHOUT
 INSTALLING A CONFLICT STRUCTURE WITH THE DRAINAGE PIPE.
  
 4. PROVIDE CCTV OF DRAINAGE SYSTEM ON 19TH STREET WEST
 OF EAST PARKWAY AND ON EAST PARKWAY FROM 19TH STREET TO
 THE MANHOLE NORTH OF 19TH STREET.
  
 5. DRAINAGE SYSTEM TO BE DESIGN PER SFWMD ERP CRITERIA.
  
 6. LABEL PROPOSED PIPE SIZES AND MATERIAL. MINIMUM 15"
 RCP PIPE TO BE USED WITHIN THE RIGHT-OF-WAY.
  
 7. LABEL VERTICAL DATUM AND PROVIDE CONVERSION EQUATION
 TO NGVD 1929.
  
 8. LAYOUT UTILITIES TO AVOID EXISTING TREES IF
 POSSIBLE.
  
 9. LABEL THE EXISTING DRAINAGE PIPE SIZE FROM THE ROUND
 CONCRETE PLAY AREA.
  
 10. PROVIDE EXFILTRATION TRENCH DETAIL WITH DIMENSIONS.
  
 11. ASPHALT MODIFICATION NEXT TO A CURB RAMP WILL
 REQUIRE THE CURB RAMP TO BE CONSTRUCTED TO CURRENT
 STANDARDS.
  
  
 THE FOLLOWING COMMENTS MUST BE ADDRESSED PRIOR TO
 ISSUANCE OF CONSTRUCTION AUTHORIZATION INCLUDING
 BUILDING PERMITS AND ENGINEERING DEVELOPMENT APPROVAL.
  
 1. AN ENGINEERING DEVELOPMENT APPROVAL APPLICATION MAY
 BE REQUIRED FROM THE ENGINEERING SERVICES DEPARTMENT.
 THE ENGINEERING DEVELOPMENT APPROVAL APPLICATION FORMS
 CAN BE DOWNLOADED AT: HTTP://WPB.ORG/DEPARTMENTS/ENGINE
 ERING-PUBLIC-WORKS/FORMS,-PERMITS-APPLICATIONS
  
 2. EROSION CONTROL PLAN AND DETAILS TO BE SUBMITTED
 WITH THE ENGINEERING PERMIT APPLICATION.
  
 3. PROVIDE A COPY OF THE SFWMD ERP PRIOR TO STARTING
 CONSTRUCTION.
  
 TRACY WARD, PE
 SENIOR STORMWATER ENGINEER
 ENGINEERING SERVICES DEPARTMENT
 561-494-1120
 [email protected]
  
  

Review Stop SURVEY SURVEYING
Rev No 3 Status P Date 09-24-2021 Cont ID  
Sent By vnoel Date 09-24-2021 Time 07:43 Rev Time 0.00
Received By vnoel Date   Time   Sent To  
Notes
***NONE***

Review Stop SURVEY SURVEYING
Rev No 2 Status F Date 06-17-2021 Cont ID  
Sent By vnoel Date 06-17-2021 Time 07:58 Rev Time 0.00
Received By vnoel Date   Time   Sent To  
Notes
2021-06-17 08:18:401. NO LEGAL DESCRIPTION ON SURVEY.
 2. BEARING BASE IS MISSING.
 3. PROPERTY CORNERS ARE NOT IDENTIFIED.
 4. PARENT BENCHMARK NOT IDENTIFIED.
 5. ADD CONVERSION TO NGVD-29.
 6. 19TH STREET IS LABELED AS 19+TH.
 7. 0.6' CURB IS MISSPELLED.

Review Stop SURVEY SURVEYING
Rev No 1 Status F Date 11-13-2019 Cont ID  
Sent By vnoel Date 11-13-2019 Time 08:12 Rev Time  
Received By vnoel Date   Time   Sent To  
Notes
2019-11-13 08:23:321. SURVEY AND ENGINEERING PLANS ARE ALMOST ILLEGIBLE.
 2. SURVEY NEEDS TO BE SIGNED AND SEALED AS A SPECIFIC
 PURPOSE SURVEY.
 3. ALL AS-BUILT ELEVATIONS NEED TO BE VERIFIED BY
 SURVEY, NOT SHOWN AS PER CITY RECORDS.
 4. SHOW RELOCATION OF HOSE BIBS.
 5. PAVEMENT REPAIR DOES NOT MEET CITY STANDARD.

Review Stop TRAFFIC TRAFFIC ENGINEERING
Rev No 3 Status P Date 09-24-2021 Cont ID  
Sent By   Date 09-24-2021 Time   Rev Time 0.00
Received By   Date   Time   Sent To  
Notes
2021-09-24 17:57:53NO FURTHER COMMENTS
  
 1. SATISFIED. PROVIDE A TRAFFIC STATEMENT.
 2. SATISFIED. INCLUDE PARKING CALCULATIONS ON THE SITE
 DATA TABLE.
 3. SATISFIED. CLARIFY HOW PARKING IS HANDLED FOR
 PROGRAMMED EVENTS, IF ANY.
 4. SATISFIED. INCLUDE BICYCLE PARKING ON THE SITE PLAN.
 CONSIDER PROVIDING ADDITIONAL BICYCLE PARKING SPACES
 BEYOND CODE REQUIREMENTS.
 5. SATISFIED. REPAVE 19TH STREET AND EAST PARKWAY AFTER
 UTILITY TIE-IN.
 6. SATISFIED. PROVIDE PEDESTRIAN CONNECTION TO THE
 PROPOSED GYMNASIUM.
 7. SATISFIED. PROVIDE CROSSWALK AT THE EAST
 PARKWAY/20TH STREET INTERSECTION, ACROSS EAST PARKWAY
 AT 21ST STREET AND 19TH STREET.
 8. SATISFIED. CROSSWALK ACROSS EAST PARKWAY MUST BE
 PERPENDICULAR. ADD ANOTHER CROSSWALK ON THE NORTHERN
 SIDE. CLOSE EXISTING CENTRAL RAMP, INSTALL TWO NEW
 RAMPS AT THE CORRESPONDING CROSSWALK LOCATION
 9. SATISFIED. PLEASE SHOW CURBS AND CURB-CUTS ON BOTH
 SIDES OF STREET SURROUNDING THE SITE.
 10. SATISFIED. PLEASE SHOW RIGHT-OF-WAY WIDTHS AND
 STREET WIDTHS.
 11. SATISFIED. PROVIDE PHOTOMETRICS FOR THE SITE.
 12. SATISFIED. PLEASE VERIFY IF THERE ARE SUFFICIENT
 ON-STREET LIGHTINGS SURROUNDING THE SITE AS MOST
 VISITORS ARE EXPECTED TO PARK ON-STREET.
 13. SATISFIED. PLEASE VERIFY ALL EXISTING UTILITIES ARE
 ACCOMMODATED AS IT APPEARS THE PROPOSED BUILDING IS
 DIRECTLY ON TOP OF EXISTING UTILITIES.
 14. SATISFIED. PLEASE VERIFY ALL IRRIGATION NEEDS ARE
 PROPERLY ADDRESSED.
 15. SATISFIED. PLEASE VERIFY ALL DRAINAGE NEEDS ON
 ROADWAYS ALONG THE SITE FRONTAGE ARE PROPERLY
 ADDRESSED.
  
 VALERIO ORICCHIO
 CITY TRANSPORTATION ENGINEER
 561-494-1092
 [email protected]
  

Review Stop TRAFFIC TRAFFIC ENGINEERING
Rev No 2 Status F Date 06-22-2021 Cont ID  
Sent By   Date 06-22-2021 Time   Rev Time 0.00
Received By   Date   Time   Sent To  
Notes
2021-06-22 18:44:331. SATISFIED. PROVIDE A TRAFFIC STATEMENT.
 2. SATISFIED. INCLUDE PARKING CALCULATIONS ON THE SITE
 DATA TABLE.
 3. SATISFIED. CLARIFY HOW PARKING IS HANDLED FOR
 PROGRAMMED EVENTS, IF ANY.
 4. SATISFIED. INCLUDE BICYCLE PARKING ON THE SITE PLAN.
 CONSIDER PROVIDING ADDITIONAL BICYCLE PARKING SPACES
 BEYOND CODE REQUIREMENTS.
 5. SATISFIED. REPAVE 19TH STREET AND EAST PARKWAY AFTER
 UTILITY TIE-IN.
 6. SATISFIED. PROVIDE PEDESTRIAN CONNECTION TO THE
 PROPOSED GYMNASIUM.
 7. PARTIALLY SATISFIED. PROVIDE CROSSWALK AT THE EAST
 PARKWAY/20TH STREET INTERSECTION, ACROSS EAST PARKWAY
 AT 21ST STREET AND 19TH STREET.
 8. CROSSWALK ACROSS EAST PARKWAY MUST BE PERPENDICULAR.
 ADD ANOTHER CROSSWALK ON THE NORTHERN SIDE. CLOSE
 EXISTING CENTRAL RAMP, INSTALL TWO NEW RAMPS AT THE
 CORRESPONDING CROSSWALK LOCATION
 9. NOT SATISFIED. PLEASE SHOW CURBS AND CURB-CUTS ON
 BOTH SIDES OF STREET SURROUNDING THE SITE.
 10. SATISFIED. PLEASE SHOW RIGHT-OF-WAY WIDTHS AND
 STREET WIDTHS.
 11. SATISFIED. PROVIDE PHOTOMETRICS FOR THE SITE.
 12. SATISFIED. PLEASE VERIFY IF THERE ARE SUFFICIENT
 ON-STREET LIGHTINGS SURROUNDING THE SITE AS MOST
 VISITORS ARE EXPECTED TO PARK ON-STREET.
 13. SATISFIED. PLEASE VERIFY ALL EXISTING UTILITIES ARE
 ACCOMMODATED AS IT APPEARS THE PROPOSED BUILDING IS
 DIRECTLY ON TOP OF EXISTING UTILITIES.
 14. SATISFIED. PLEASE VERIFY ALL IRRIGATION NEEDS ARE
 PROPERLY ADDRESSED.
 15. SATISFIED. PLEASE VERIFY ALL DRAINAGE NEEDS ON
 ROADWAYS ALONG THE SITE FRONTAGE ARE PROPERLY
 ADDRESSED.
  
 VALERIO ORICCHIO
 CITY TRANSPORTATION ENGINEER
 561-494-1092
 [email protected]
  
  

Review Stop TRAFFIC TRAFFIC ENGINEERING
Rev No 1 Status F Date   Cont ID  
Sent By   Date 11-12-2019 Time   Rev Time  
Received By   Date   Time   Sent To  
Notes
2019-11-12 14:48:041. PROVIDE A TRAFFIC STATEMENT.
 2. INCLUDE PARKING CALCULATIONS ON THE SITE DATA TABLE.
 3. CLARIFY HOW PARKING IS HANDLED FOR PROGRAMMED
 EVENTS, IF ANY.
 4. INCLUDE BICYCLE PARKING ON THE SITE PLAN. CONSIDER
 PROVIDING ADDITIONAL BICYCLE PARKING SPACES BEYOND CODE
 REQUIREMENTS.
 5. REPAVE 19TH STREET AND EAST PARKWAY AFTER UTILITY
 TIE-IN.
 6. PROVIDE PEDESTRIAN CONNECTION TO THE PROPOSED
 GYMNASIUM.
 7. PROVIDE CROSSWALK AT THE EAST PARKWAY/20TH STREET
 INTERSECTION, ACROSS EAST PARKWAY AT 21ST STREET AND
 19TH STREET, AND AT MIDBLOCK LOCATIONS ACROSS 19TH
 STREET.
 8. PLEASE SHOW CURBS AND CURB-CUTS ON BOTH SIDES OF
 STREET SURROUNDING THE SITE.
 9. PLEASE SHOW RIGHT-OF-WAY WIDTHS AND STREET WIDTHS.
 10. PROVIDE PHOTOMETRICS FOR THE SITE.
 11. PLEASE VERIFY IF THERE ARE SUFFICIENT ON-STREET
 LIGHTINGS SURROUNDING THE SITE AS MOST VISITORS ARE
 EXPECTED TO PARK ON-STREET.
 12. PLEASE VERIFY ALL EXISTING UTILITIES ARE
 ACCOMMODATED AS IT APPEARS THE PROPOSED BUILDING IS
 DIRECTLY ON TOP OF EXISTING UTILITIES.
 13. PLEASE VERIFY ALL IRRIGATION NEEDS ARE PROPERLY
 ADDRESSED.
 14. PLEASE VERIFY ALL DRAINAGE NEEDS ON ROADWAYS ALONG
 THE SITE FRONTAGE ARE PROPERLY ADDRESSED.
  
 SHING TSOI
 CITY IN-HOUSE TRAFFIC CONSULTANT
 561-494-1141
 [email protected]
 (IN-HOUSE ON TUESDAYS AND WEDNESDAYS)
  

Review Stop Z ZONING
Rev No 3 Status P Date 10-01-2021 Cont ID  
Sent By jroach Date 10-01-2021 Time 08:49 Rev Time 0.00
Received By jroach Date 10-01-2021 Time 08:49 Sent To  
Notes
2021-10-01 08:59:58PLANS AND PLATS REVIEW COMMITTEE (PPRC) ZONING REVIEW
 ________________________________________
  
 DATE OF REVIEW: 10.01.2021
 PROJECT NO.: Z19090032
 CASE NO.: FSPR 19-06
 ________________________________________
  
 REVIEW STATUS: PASSED WITH PROVISOS
 ________________________________________
  
 THIS REVIEW HAS BEEN PASSED SUBJECT TO THE FOLLOWING
 PROVISOS:
  
 1. PRIOR TO ISSUANCE OF A BUILDING PERMIT:
  
  1.1. UTILITY LETTERS SHALL BE PROVIDED FROM ALL
 UTILITY COMPANIES (SEE PAGES 6-7 OF THE DEVELOPMENT
 APPLICATION).
  
  1.2. PER SEC. 94-233(C)(4) OF THE CITY'S ZLDRS, THE
 MAXIMUM FAR ALLOWED IS 0.2 - THE SITE DATA TABLE
 INDICATES ONLY 0.75 IS PERMITTED. PLEASE ADJUST
 ACCORDINGLY.
  
  1.3. PER SEC 94-233(B) OF THE CITY'S ZLDRS, THE
 MAXIMUM BUILDING HEIGHT PERMITTED IS 40 FEET - THE SITE
 DATA TABLE INDICATES 30 FEET. PLEASE ADJUST
 ACCORDINGLY.
  
 2. THE PROJECT SHALL COMPLY WITH SEC. 255.2575, FLORIDA
 STATUTES, REGARDING CONSTRUCTION OF AN ENERGY-EFFICIENT
 AND SUSTAINABLE BUILDING.
  
 3. THE A/C EQUIPMENT PADS/AREA TO THE WEST OF THE
 PROPOSED GYMNASIUM NEEDS TO BE SCREENED FROM VIEW WITH
 A WALL OR OPAQUE FENCE CONSISTING OF BRICK, DECORATIVE
 CONCRETE, OTHER DECORATIVE MASONRY, OR COMPARABLY
 DURABLE WOOD/STEEL. CHAIN LINK FENCING WITH SLATS DOES
 NOT COMPLY WITH THIS REQUIREMENT. ADDITIONALLY,
 LANDSCAPING WITH SHRUBS/HEDGES SHALL ALSO BE PROVIDED
 IN FRONT OF THE FENCE/WALL TO THE MAXIMUM EXTENT
 FEASIBLE.
 ________________________________________
  
 QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING:
  
 JOHN P. ROACH, AICP, PRINCIPAL PLANNER
 CITY OF WEST PALM BEACH
 DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION
 401 CLEMATIS STREET - P.O. BOX 3147
 WEST PALM BEACH, FLORIDA 33402
  
 P: 561.822.1448
 TTY: 800.955.8771
 E: [email protected]
  
 W: WPB.ORG
  

Review Stop Z ZONING
Rev No 2 Status F Date 07-12-2021 Cont ID  
Sent By jroach Date 07-12-2021 Time 15:07 Rev Time 0.00
Received By jroach Date 07-12-2021 Time 14:39 Sent To  
Notes
2021-07-12 15:07:34PLANS AND PLATS REVIEW COMMITTEE (PPRC) ZONING REVIEW
 ________________________________________
  
 DATE OF REVIEW: 07.12.2021
 PROJECT NO.: Z19090032
 CASE NO.: FSPR 19-06
 ________________________________________
  
 PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING
 REVIEW COMMENTS:
  
 1. [ PARTIALLY SATISFIED ] - PURSUANT TO THE
 DEVELOPMENT APPLICATION, THE FOLLOWING INFORMATION
 SHALL BE PROVIDED:
  
 1.1. [ SATISFIED ] - TWO (2) COPIES OF AN APPROVED
 TRAFFIC CONCURRENCY DETERMINATION FROM PALM BEACH
 COUNTY DEPARTMENT OF ENGINEERING AND PUBLIC WORKS ?
 TRAFFIC DIVISION INDICATING THAT THE PROPOSED PROJECT
 MEETS THE TRAFFIC PERFORMANCE STANDARDS OF PALM BEACH
 COUNTY.
  
 1.2. [ SATISFIED ] - A JUSTIFICATION STATEMENT
 PROVIDING A GENERAL DESCRIPTION OF THE REQUEST, RELATED
 BACKGROUND INFORMATION ON THE PROJECT AND SITE, AND
 JUSTIFICATION, SPECIAL REASONS, OR BASIS FOR THE
 REQUEST.
  
 1.3. [ SATISFIED ] - LANDSCAPE PLANS CONTAINING ALL
 INFORMATION CONTAINED IN THE LANDSCAPE PLAN CHECKLIST
 (PAGE 15 OF THE DEVELOPMENT APPLICATION).
  
 1.4. [ SATISFIED ] - ELECTRONIC COPIES OF ALL
 DOCUMENTS, PLANS, ETC. SHALL BE PROVIDED.
  
 1.5. [ SATISFIED ] - A COPY OF THE WARRANTY DEED FOR
 THE PROPERTY SHALL BE PROVIDED.
  
 1.6. [ NOT SATISFIED ] - UTILITY LETTERS SHALL BE
 PROVIDED FROM ALL UTILITY COMPANIES (SEE PAGES 6-7 OF
 THE DEVELOPMENT APPLICATION).
  
 1.7. [ SATISFIED ] - RESPONSES TO THE STANDARDS FOR
 CODE COMPLIANCE (SEE PAGE 30 OF THE DEVELOPMENT
 APPLICATION).
  
 1.8. [ SATISFIED ] - A CURRENT AND ACCURATE SURVEY
 PROVING ALL ITEMS LISTED ON PAGES 5-6 OF THE
 DEVELOPMENT APPLICATION.
  
 2. [ PARTIALLY SATISFIED ] - THE SITE PLAN SHALL
 CONTAIN ALL OF THE INFORMATION REQUIRED BY THE SITE
 PLAN CHECKLIST, AS LISTED ON PAGE 14 OF THE DEVELOPMENT
 APPLICATION.
  
 2.1 [ NEW COMMENT ] - FOR THE SITE DATA TABLE,
 PERCENTAGES ASSOCIATED WITH IMPERVIOUS SURFACE AREA,
 OPEN SPACE, BUILDING COVERAGE, ETC. SHOULD BE REFLECTED
 AS A PERCENTAGE OF THE OVERALL SITE AREA.
  
 2.2. [ NEW COMMENT ] - PER SEC. 94-232(C)(4) OF THE
 CITY'S ZLDRS, THE MAXIMUM FAR ALLOWED IS 0.75 - THE
 SITE DATA TABLE INDICATES ONLY 0.2 IS PERMITTED. PLEASE
 ADJUST ACCORDINGLY.
  
 2.3. [ NEW COMMENT ] - PER SEC 94-232(B) OF THE CITY'S
 ZLDRS, THE MAXIMUM BUIDLING PERMITTED IS 30 FEET - THE
 SITE DATA TABLE INDICATES 40 FEET. PLEASE ADJUST
 ACCORDINGLY.
  
 3. [ SATISFIED ] - OWNER?S CONSENT FORM SHALL BE SIGNED
 BY THE MAYOR, NOT STAFF.
  
 4. [ SATISFIED ] - THE FOLLOWING INFORMATION ON SHEET
 A0.0 IS INCORRECT:
  
 4.1. [ SATISFIED ] - NAME OF MAYOR
  
 4.2. [ SATISFIED ] - SPELLING OF COMMISSIONER SHOAF?S
 NAME
  
 4.3. [ SATISFIED ] - SPELLING OF COMMISSIONER NEERING?S
 NAME
  
 4.4. [ SATISFIED ] - NAME OF DISTRICT 3 COMMISSIONER
  
 4.5. [ SATISFIED ] - NAME OF DISTRICT 4 COMMISSIONER
  
 4.6. [ SATISFIED ] - ZONING DISTRICT IN THE PROJECT
 DATA
  
 5. [ SATISFIED ] - THE FOLLOWING INFORMATION ON ERDMAN
 ANTHONY COVER SHEET IS INCORRECT:
  
 5.1. [ SATISFIED ] - NAME OF MAYOR
  
 5.2. [ SATISFIED ] - NAME OF DISTRICT 3 COMMISSIONER
  
 5.3. [ SATISFIED ] - NAME OF DISTRICT 4 COMMISSIONER
  
 5.4. [ SATISFIED ] - NAME OF THE CITY ADMINISTRATOR
  
 6. [ SATISFIED ] - THE LOCATION OF THE PROPERTY LINE,
 SHOWN ON THE SITE PLAN, DOES NOT APPEAR TO MATCH THAT
 WHICH IS SHOWN ON THE EXISTING CONDITIONS SURVEY. AS
 STATE ABOVE, A CURRENT AND ACCURATE SURVEY SHALL BE
 PROVIDED AND SHALL BE THE BASIS FOR ALL SITE PLANS,
 ETC.
  
 7. [ SATISFIED ] - WINDOW DETAIL SHALL BE PROVIDED
 SHOWING THAT ALL WINDOWS WILL BE RECESSED A MINIMUM OF
 TWO (2) INCHES, AS REQUIRED BY SEC. 94-222(H)(6) OF THE
 CITY?S ZLDRS.
  
 8. [ SATISFIED ] - ELEVATIONS SHALL INDICATE THE
 OVERALL HEIGHT OF THE BUILDING, AS DEFINED BY THE
 CITY?S ZLDRS.
  
 9. [ SATISFIED ] - PLEASE PROVIDE THE INFORMATION ON
 THE PLANS NECESSARY TO SHOW COMPLIANCE WITH ARTICLE XV
 (PARKING) OF THE CITY?S ZLDRS. PLEASE NOTE THAT
 ON-STREET PARKING IMMEDIATELY ADJACENT TO THE SUBJECT
 PROPERTY CAN BE COUNTED TOWARD THE PARKING
 REQUIREMENTS, HOWEVER, PLEASE PROVIDE CONFIRMATION FROM
 THE CITY?S TRAFFIC ENGINEER INDICATING THAT ON-STREET
 PARKING IS ALLOWED ON SUCH STREETS, AND PROVIDE THE
 NUMBER OF SPACES THAT CAN BE ACCOMMODATED.
  
 10. [ SATISFIED ] - THE SITE PLAN INDICATES THAT THERE
 ARE EIGHT (8) SPACES WITHIN THE EXISTING PARKING LOT,
 HOWEVER, IT APPEARS THAT THERE ARE MAY BE NINE (9) OR
 TEN (10) SPACES. VERIFY WITH THE SURVEY AND ADJUST THE
 SITE PLAN ACCORDINGLY.
  
 11. [ SATISFIED ] - BICYCLE PARKING SHALL BE PROVIDED
 IN ACCORDANCE WITH SEC. 94-485(Q) OF THE CITY?S ZLDRS.
 ENSURE THAT SUFFICIENT BICYCLE PARKING IS PROVIDED FOR
 THE NEW GYMNASIUM, AS WELL AS THE EXISTING COMMUNITY
 CENTER.
  
 12. [ PARTIALLY SATISFIED ] - PLEASE CONFIRM THAT THE
 PROJECT HAS BEEN PRESENTED TO THE COLEMAN PARK
 NEIGHBORHOOD ASSOCIATION AND THAT RESIDENT FEEDBACK HAS
 BEEN INCORPORATED INTO THE PLAN. A PRESENTATION SHALL
 ALSO BE MADE TO THE COLEMAN PARK TASK FORCE (PLEASE
 CONTACT ME FOR UPCOMING MEETING DATES).
  
 12.1. [ NEW COMMENT ] - PLANNING STAFF WILL CONFIRM
 WITH THE TAKS FORCE IN THEIR UPCOMING MEETING THAT THIS
 PRESENTATION WAS MADE AND THAT ALL FEEDBACK HAS BEEN
 INCORPORATED INOT THE PLAN.
  
 13. [ PARTIALLY SATISFIED ] - PROVIDE INFORMATION
 INDICATING THAT THE PROJECT WILL COMPLY WITH SEC.
 255.2575, FLORIDA STATUTES, REGARDING CONSTRUCTION OF
 AN ENERGY-EFFICIENT AND SUSTAINABLE BUILDING. VERIFY
 WHETHER OR NOT SIMILAR PROVISIONS ARE CONTAINED IN THE
 CITY?S CODE OF ORDINANCES.
  
 13.1 [ NEW COMMENT ] - PLANNING STAFF IS CONFIRMING
 WHAT "RATING SYSTEM" OR "GREEN BUILDING CODE" NEEDS TO
 BE ADHERED TO, AND AT WHAT LEVEL. ADDITIONAL
 INFORMATION WILL BE PROVIDED.
  
 14. [ NEW COMMENT ] - THE A/C EQUIPMENT PADS/AREA NEEDS
 TO BE SCREENED FROM VIEW WITH A WALL OR OPAQUE FENCE
 CONSISTING OF BRICK, DECORATIVE CONCRETE, OTHER
 DECORATIVE MASONRY, OR COMPARABLY DURABLE WOOD/STEEL.
 LANDSCAPING WITH SHRUBS/HEDGES SHALL ALSO BE PROVIDED.
 ________________________________________
  
 PLEASE NOTE THE FOLLOWING WHEN RESUBMITTING:
  
 A) WRITTEN RESPONSES TO COMMENTS MADE BY ALL
 DEPARTMENTS SHALL BE PROVIDED UPON RESUBMISSION.
  
 B) ELECTRONIC COPY (PDF) OF ALL REVISED PLANS/DOCUMENTS
 SHALL BE PROVIDED.
  
 C) PLEASE NOTE THAT RE-SUBMITTALS MAY BE SUBJECT TO
 ADDITIONAL COMMENTS.
  
 D) IF NO RESPONSE IS RECEIVED WITHIN 60 DAYS OF THE
 ISSUANCE OF THESE COMMENTS, THE APPLICATION WILL BE
 CONSIDERED WITHDRAWN AND ANY FURTHER ACTION WILL
 REQUIRE SUBMISSION OF A NEW DEVELOPMENT APPLICATION.
  
 E) PLEASE NOTE THAT YOU WILL BE PERMITTED ONE (1)
 RESUBMITTAL AT NO ADDITIONAL COST. IF PREVIOUSLY-ISSUED
 COMMENTS CONTINUE TO NOT BE SUFFICIENTLY ADDRESSED, THE
 APPLICANT WILL BE ACCESSED A RESUBMITTAL FEE. SUCH FEE
 WILL BE 20% OF THE ORIGINAL APPLICATION FEE.
 ________________________________________
  
 QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING:
  
 JOHN P. ROACH, AICP, PRINCIPAL PLANNER
 CITY OF WEST PALM BEACH
 DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION
 401 CLEMATIS STREET - P.O. BOX 3147
 WEST PALM BEACH, FLORIDA 33402
  
 P: 561.822.1448
 TTY: 800.955.8771
 E: [email protected]
  
 W: WPB.ORG
  

Review Stop Z ZONING
Rev No 1 Status F Date 11-13-2019 Cont ID  
Sent By jroach Date 11-13-2019 Time 10:45 Rev Time 0.00
Received By jroach Date 11-13-2019 Time 10:45 Sent To  
Notes
2019-11-13 10:46:11PLANS AND PLATS REVIEW COMMITTEE (PPRC) ZONING REVIEW
 ________________________________________
  
 DATE OF REVIEW: 11.13.2019
 PROJECT NO.: Z19090032
 CASE NO.: FSPR 19-06
 ________________________________________
  
 PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING
 REVIEW COMMENTS:
  
 1. PURSUANT TO THE DEVELOPMENT APPLICATION, THE
 FOLLOWING INFORMATION SHALL BE PROVIDED:
  
 1.1. TWO (2) COPIES OF AN APPROVED TRAFFIC CONCURRENCY
 DETERMINATION FROM PALM BEACH COUNTY DEPARTMENT OF
 ENGINEERING AND PUBLIC WORKS ? TRAFFIC DIVISION
 INDICATING THAT THE PROPOSED PROJECT MEETS THE TRAFFIC
 PERFORMANCE STANDARDS OF PALM BEACH COUNTY.
  
 1.2. A JUSTIFICATION STATEMENT PROVIDING A GENERAL
 DESCRIPTION OF THE REQUEST, RELATED BACKGROUND
 INFORMATION ON THE PROJECT AND SITE, AND JUSTIFICATION,
 SPECIAL REASONS, OR BASIS FOR THE REQUEST.
  
 1.3. LANDSCAPE PLANS CONTAINING ALL INFORMATION
 CONTAINED IN THE LANDSCAPE PLAN CHECKLIST (PAGE 15 OF
 THE DEVELOPMENT APPLICATION).
  
 1.4. ELECTRONIC COPIES OF ALL DOCUMENTS, PLANS, ETC.
 SHALL BE PROVIDED.
  
 1.5. A COPY OF THE WARRANTY DEED FOR THE PROPERTY SHALL
 BE PROVIDED.
  
 1.6. UTILITY LETTERS SHALL BE PROVIDED FROM ALL UTILITY
 COMPANIES (SEE PAGES 6-7 OF THE DEVELOPMENT
 APPLICATION).
  
 1.7. RESPONSES TO THE STANDARDS FOR CODE COMPLIANCE
 (SEE PAGE 30 OF THE DEVELOPMENT APPLICATION).
  
 1.8. A CURRENT AND ACCURATE SURVEY PROVING ALL ITEMS
 LISTED ON PAGES 5-6 OF THE DEVELOPMENT APPLICATION.
  
 2. THE SITE PLAN SHALL CONTAIN ALL OF THE INFORMATION
 REQUIRED BY THE SITE PLAN CHECKLIST, AS LISTED ON PAGE
 14 OF THE DEVELOPMENT APPLICATION.
  
 3. OWNER?S CONSENT FORM SHALL BE SIGNED BY THE MAYOR,
 NOT STAFF.
  
 4. THE FOLLOWING INFORMATION ON SHEET A0.0 IS
 INCORRECT:
  
 4.1. NAME OF MAYOR
  
 4.2. SPELLING OF COMMISSIONER SHOAF?S NAME
  
 4.3. SPELLING OF COMMISSIONER NEERING?S NAME
  
 4.4. NAME OF DISTRICT 3 COMMISSIONER
  
 4.5. NAME OF DISTRICT 4 COMMISSIONER
  
 4.6. ZONING DISTRICT IN THE PROJECT DATA
  
 5. THE FOLLOWING INFORMATION ON ERDMAN ANTHONY COVER
 SHEET IS INCORRECT:
  
 5.1. NAME OF MAYOR
  
 5.2. NAME OF DISTRICT 3 COMMISSIONER
  
 5.3. NAME OF DISTRICT 4 COMMISSIONER
  
 5.4. NAME OF THE CITY ADMINISTRATOR
  
 6. THE LOCATION OF THE PROPERTY LINE, SHOWN ON THE SITE
 PLAN, DOES NOT APPEAR TO MATCH THAT WHICH IS SHOWN ON
 THE EXISTING CONDITIONS SURVEY. AS STATE ABOVE, A
 CURRENT AND ACCURATE SURVEY SHALL BE PROVIDED AND SHALL
 BE THE BASIS FOR ALL SITE PLANS, ETC.
  
 7. WINDOW DETAIL SHALL BE PROVIDED SHOWING THAT ALL
 WINDOWS WILL BE RECESSED A MINIMUM OF TWO (2) INCHES,
 AS REQUIRED BY SEC. 94-222(H)(6) OF THE CITY?S ZLDRS.
  
 8. ELEVATIONS SHALL INDICATE THE OVERALL HEIGHT OF THE
 BUILDING, AS DEFINED BY THE CITY?S ZLDRS.
  
 9. PLEASE PROVIDE THE INFORMATION ON THE PLANS
 NECESSARY TO SHOW COMPLIANCE WITH ARTICLE XV (PARKING)
 OF THE CITY?S ZLDRS. PLEASE NOTE THAT ON-STREET PARKING
 IMMEDIATELY ADJACENT TO THE SUBJECT PROPERTY CAN BE
 COUNTED TOWARD THE PARKING REQUIREMENTS, HOWEVER,
 PLEASE PROVIDE CONFIRMATION FROM THE CITY?S TRAFFIC
 ENGINEER INDICATING THAT ON-STREET PARKING IS ALLOWED
 ON SUCH STREETS, AND PROVIDE THE NUMBER OF SPACES THAT
 CAN BE ACCOMMODATED.
  
 10. THE SITE PLAN INDICATES THAT THERE ARE EIGHT (8)
 SPACES WITHIN THE EXISTING PARKING LOT, HOWEVER, IT
 APPEARS THAT THERE ARE MAY BE NINE (9) OR TEN (10)
 SPACES. VERIFY WITH THE SURVEY AND ADJUST THE SITE PLAN
 ACCORDINGLY.
  
 11. BICYCLE PARKING SHALL BE PROVIDED IN ACCORDANCE
 WITH SEC. 94-485(Q) OF THE CITY?S ZLDRS. ENSURE THAT
 SUFFICIENT BICYCLE PARKING IS PROVIDED FOR THE NEW
 GYMNASIUM, AS WELL AS THE EXISTING COMMUNITY CENTER.
  
 12. PLEASE CONFIRM THAT THE PROJECT HAS BEEN PRESENTED
 TO THE COLEMAN PARK NEIGHBORHOOD ASSOCIATION AND THAT
 RESIDENT FEEDBACK HAS BEEN INCORPORATED INTO THE PLAN.
 A PRESENTATION SHALL ALSO BE MADE TO THE COLEMAN PARK
 TASK FORCE (PLEASE CONTACT ME FOR UPCOMING MEETING
 DATES).
  
 13. PROVIDE INFORMATION INDICATING THAT THE PROJECT
 WILL COMPLY WITH SEC. 255.2575, FLORIDA STATUTES,
 REGARDING CONSTRUCTION OF AN ENERGY-EFFICIENT AND
 SUSTAINABLE BUILDING. VERIFY WHETHER OR NOT SIMILAR
 PROVISIONS ARE CONTAINED IN THE CITY?S CODE OF
 ORDINANCES.
  
 ________________________________________
  
 PLEASE NOTE THE FOLLOWING WHEN RESUBMITTING:
  
 A) WRITTEN RESPONSES TO COMMENTS MADE BY ALL
 DEPARTMENTS SHALL BE PROVIDED UPON RESUBMISSION.
  
 B) 4 SETS OF REVISED PLANS AND/OR DOCUMENTS SHALL BE
 PROVIDED, ALONG WITH ONE (1) REDUCED COPY (11IN X
 17IN), AND AN ELECTRONIC COPY OF ALL PLANS.
  
 C) PLEASE NOTE THAT RE-SUBMITTALS MAY BE SUBJECT TO
 ADDITIONAL COMMENTS.
  
 D) IF NO RESPONSE IS RECEIVED WITHIN 60 DAYS OF THE
 ISSUANCE OF THESE COMMENTS, THE APPLICATION WILL BE
 CONSIDERED WITHDRAWN AND ANY FURTHER ACTION WILL
 REQUIRE SUBMISSION OF A NEW DEVELOPMENT APPLICATION.
  
 E) PLEASE NOTE THAT YOU WILL BE PERMITTED ONE (1)
 RESUBMITTAL AT NO ADDITIONAL COST. IF PREVIOUSLY-ISSUED
 COMMENTS CONTINUE TO NOT BE SUFFICIENTLY ADDRESSED, THE
 APPLICANT WILL BE ACCESSED A RESUBMITTAL FEE. SUCH FEE
 WILL BE 20% OF THE ORIGINAL APPLICATION FEE.
 ________________________________________
  
 QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING:
  
 JOHN P. ROACH, AICP, PRINCIPAL PLANNER
 CITY OF WEST PALM BEACH
 DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION
 401 CLEMATIS STREET - P.O. BOX 3147
 WEST PALM BEACH, FLORIDA 33402
  
 P: 561.822.1448
 TTY: 800.955.8771
 E: [email protected]
  
 W: WPB.ORG
  

  Print