Plan Review Details - Project Z19090015
| Plan Review Stops For Project Z19090015 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
10-09-2019 |
|
|
Cont ID |
|
| Sent By |
rbrown |
Date |
10-09-2019 |
Time |
19:46 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
10-09-2019 |
Time |
19:46 |
Sent To |
|
|
| Notes |
| 2019-10-09 19:55:49 | DEVELOPMENT SERVICES DEPARTMENT, BUILDING DIVISION, | | | COMMENTS: | | | | | | 1. THIS REVIEW IS A CURSORY REVIEW AS IT RELATES TO THE | | | SITE. IT IS NOT A REVIEW FOR FULL COMPLIANCE WITH | | | FLORIDA BUILDING CODE. THE FOLLOWING COMMENTS ARE TO BE | | | ADDRESSED FOR THE BUILDING PERMIT APPLICATION. | | | | | | 2. FLOOD ZONE. ACCORDING TO THE ADOPTED FLOOD INSURANCE | | | RATE MAPS (FIRMS), THE PROPOSED BUILDING IS IN FLOOD | | | ZONE AE, WITH A BASE FLOOD ELEVATION OF 14 FT NAVD. THE | | | FIRST FLOOR OF THE BUILDING AND ALL ASSOCIATED | | | MECHANICAL EQUIPMENT (CHILLERS, GENERATORS ETC.) SHALL | | | BE AT OR ABOVE 16 FT NAVD SO THAT THEY ARE THE REQUIRED | | | 24 INCHES (FREEBOARD) ABOVE THE BASE FLOOD ELEVATION. | | | | | | 3. UNITY OF TITLE. FOR ANY BUILDING CROSSING A PROPERTY | | | LINE, EITHER A RECORDED UNITY OF TITLE, OR SOME OTHER | | | APPROVED LEGAL INSTRUMENT, SHALL BE INCLUDED WITH THE | | | PERMIT APPLICATION, OR THE BUILDING MUST HAVE A FIRE | | | WALL ALONG THE PROPERTY LINE, PER SECTION 202 OF | | | FLORIDA BUILDING CODE, BUILDING, FIRE SEPARATION | | | DISTANCE. | | | | | | 4. ACCESSIBLE ROUTE. WHEN SUBMITTED FOR PERMIT, THE | | | PLANS SHALL SHOW AT LEAST ONE ACCESSIBLE ROUTE, | | | COMPLYING WITH SECTIONS 206.2 AND 402.2 OF FLORIDA | | | ACCESSIBILITY CODE, CONNECTING ACCESSIBLE BUILDING OR | | | FACILITY ENTRANCES WITH ALL ACCESSIBLE SPACES AND | | | ELEMENTS WITHIN THE BUILDING OR FACILITY | | | | | | 5. NUMBER OF ACCESSIBLE PARKING SPACES. OVERALL SITE | | | PLAN, SHEET OSP, STATES THAT 9 ACCESSIBLE PARKING | | | SPACES ARE PROVIDED BUT THE PLANS APPEAR TO SHOW ONLY | | | 8. ALSO 2% OF THE NUMBER OF PROVIDED PARKING SPACES | | | SHALL BE ACCESSIBLE, SO 11 ACCESSIBLE PARKING SPACES | | | ARE REQUIRED BECAUSE A TOTAL OF 509 PARKING SPACES ARE | | | PROPOSED. THE MINIMUM NUMBER OF ACCESSIBLE PARKING | | | SPACES PROVIDED SHALL BE IN ACCORDANCE WITH FAIR | | | HOUSING ACT AND SECTION 208.2 OF FLORIDA ACCESSIBILITY | | | CODE. | | | | | | 6. BUILDING SIZE. WHEN SUBMITTED FOR BUILDING PERMIT, | | | THE PLANS SHALL SHOW THAT THE TYPE OF CONSTRUCTION FOR | | | THE BUILDINGS WILL BE IN ACCORDANCE WITH THE HEIGHT, | | | AREA AND OCCUPANCY LIMITATIONS IN CHAPTER 5 OF THE | | | FLORIDA BUILDING CODE. | | | | | | 7. SEPARATE PERMITS REQUIRED. ALL APPLICABLE PERMITS | | | AND SUB-PERMITS MUST BE OBTAINED BEFORE COMMENCING THE | | | WORK. SEPARATE PERMITS, PLANS AND FEES, ARE REQUIRED | | | FOR SIGNS, SWIMMING POOLS AND SPAS, GAS SYSTEMS, | | | GENERATORS, FIRE ALARM SYSTEMS, FIRE SPRINKLER AND | | | OTHER FIRE SUPPRESSION SYSTEMS, GREASE INTERCEPTORS, | | | SITE LIGHTING, SITE LANDSCAPE, SITE IRRIGATION, ETC. | | | | | | 8. BUILDING ADDRESS. EACH SEPARATE BUILDING, AND UNIT | | | WITH AN INDEPENDENT ENTRANCE FROM THE STREET, SHALL | | | HAVE A SEPARATE ADDRESS. FOR STREET ADDRESSING, CONTACT | | | MICHAEL ORIO, GIS SUPPORT SPECIALIST, AT (561) 494 | | | 1080, OR BY EMAIL: [email protected] | | | | | | 9. ART IN PUBLIC PLACES. THIS PROJECT WILL BE SUBJECT | | | TO ART IN PUBLIC PLACES (AIPP) ASSESSMENT. FOR ADVICE | | | ON THE PROVISION OF PUBLIC ARTWORK IN LIEU OF THE AIPP | | | ASSESSMENT, CONTACT SYBILLE WELTER, ART IN PUBLIC | | | PLACES COORDINATOR, AT (561) 822-1521, OR BY EMAIL: | | | [email protected] | | | | | | ROBERT BROWN | | | BUILDING OFFICIAL | | | TEL: 561 805 6652 | | | EMAIL: [email protected] | | | |
|
|
| Review Stop |
ENG - PPRC |
ENGINEERING - PPRC |
| Rev No |
3 |
Status |
P |
Date |
01-15-2020 |
|
|
Cont ID |
|
| Sent By |
rrossano |
Date |
01-15-2020 |
Time |
|
Rev Time |
0.00 |
| Received By |
rrossano |
Date |
01-15-2020 |
Time |
|
Sent To |
|
|
| Notes |
| 2020-01-15 11:51:42 | PASSED WITH PROVISOS: | | | | | | 1. PLEASE UPDATE LOS ANALYSIS SUMMARY TABLE AND | | | RESUBMIT DIRECTLY TO ENGINEERING. | | | 2. FOR FORMAL ENGINEERING SUBMITTAL , PROVIDE | | | CALCULATIONS ON PLANS OF EXISTING AND PROPOSED DEMANDS | | | FOR WATER & SEWER (AVERAGE, MAXIMUM AND PEAK) AND FIRE | | | FLOW DEMANDS. CALCULATIONS SHALL BE PER FAC 64E-6 FOR | | | SEWER AND PER FAC 64-E.008 FOR WATER. | | | 3. FOR FORMAL ENGINEERING SUBMITTAL , PLEASE PROVIDE | | | CALCULATIONS OF REVISED PERVIOUS AND IMPERVIOUS | | | CALCULATIONS FOR THE PROPOSED IMPACTED AREAS. | | | 4. FOR FORMAL ENGINEERING SUBMITTAL , COORDINATE WITH | | | MARK HURLEY, FIELD CUSTOMER SERVICE SUPERVISOR WITH | | | CITY OF WPB PUBLIC UTILITIES, REGARDING PLACEMENT OF | | | BACKFLOW DEVICES AND WATER METERS. CONTACT HIM AT | | | 561-494-2262 OR [email protected] | | | 5. FOR FORMAL ENGINEERING SUBMITTAL , PLANS SHALL SHOW | | | PROPOSED LOCATIONS AND DIMENSIONS OF ALL WATER, | | | STORMWATER, AND SANITARY AND SEWER LINES, INCLUDING | | | STUBS TO EACH PROPERTY LINE FOR WATER AND SANITARY | | | SEWERS, THE MAKE AND MODEL OF ALL VALVES, METERS, AND | | | OTHERS DEVICES TO BE INSTALLED ON THE SYSTEM, CATCH | | | BASINS, CULVERTS, DITCHES INCLUDING GRADES, PIPES | | | SIZES, MATERIALS, ELEVATIONS, ASSUMPTIONS, | | | CALCULATIONS, INVERT ELEVATIONS FOR ALL INLETS AND | | | MANHOLES AND PROFILES OF SANITARY SEWER LINES. ALL | | | AVAILABLE ELEVATION SHALL BE SHOWN ON THE PROFILE VIEW. | | | DIRECTION OF FLOW SHALL BE SHOWN ON PLAN VIEW ON PLAN | | | VIEW FOR ALL SANITARY AND STORM SEWERS. ADDITIONALLY, | | | PLAN VIEW SHALL SHOW ALL EXISTING AND PROPOSED | | | UNDERGROUND UTILITY LAYOUT, INCLUDING FIBER OPTIC, | | | ELECTRIC, GAS, AND CABLEVISION & TELECOMMUNICATION | | | FACILITIES LOCATED ON THE RIGHT-OF-WAY. | | | 6. FOR FORMAL ENGINEERING SUBMITTAL , CUT AND CAP | | | UTILITIES NOT IN USE, AND REMOVE ANY ABANDONED UTILITY | | | LINES LARGER THAN 2 INCHES FROM CITY RIGHT OF WAY. | | | 7. FOR FORMAL ENGINEERING SUBMITTAL, PLEASE PROVIDE | | | ENLARGED VIEW ON PLANS OF PROPOSED LOCATION OF WATER | | | METER AND BACKFLOW PREVENTION. | | | 8. FOR FORMAL ENGINEERING SUBMITTAL, PLEASE CALLOUT | | | DOMESTIC BACKFLOW PREVENTER AS RPPA AND FIRE BACKFLOW | | | PREVENTER AS DCDA. SPECIFY LEAD FREE DESIGN ON ALL | | | BACKFLOWS. | | | 9. FOR FORMAL ENGINEERING SUBMITTAL, PROVIDE PROFILES | | | OF WATER AND SEWER AND SHOW ANY CROSSINGS/CONFLICTS. | | | 10. FOR FORMAL ENGINEERING SUBMITTAL, WHEN SUBMITTING | | | APPROVED MATERIALS LIST, PLEASE PROVIDE MATERIAL/CUT | | | SHEETS FOR ALL PROPOSED BACKFLOW DEVICES SHOWING | | | SPECIFIC MODEL NUMBER AND SPECIFYING USC APPROVED | | | LEAD-FREE DESIGN. | | | 11. FOR FORMAL ENGINEERING SUBMITTAL CLEARLY SHOW ROAD | | | RIGHT OF WAY. | | | 12. FOR FORMAL ENGINEERING SUBMITTAL PROVIDE SANITARY | | | ELEVATIONS AT MANHOLE TIE-IN. | | | 13. FOR FORMAL ENGINEERING SUBMITTAL, IF SANITARY LINES | | | ARE PROPOSED IN ROW PLEASE SHOW ADJACENT SANITARY | | | LATERAL LOCATIONS AND SHOW ADDRESSES OF ADJACENT | | | PARCELS. | | | 14. FOR FORMAL ENGINEERING SUBMITTAL, IF WATER LINES | | | ARE BEING REPLACED IN ROW, SHOW ADJACENT PARCEL | | | ADDRESSES. | | | 15. FOR FORMAL ENGINEERING SUBMITTAL, WHEN TRENCHING IN | | | IN CITY MAINTAINED ROADWAY AREAS ADD NOTE TO PROVIDE 50 | | | FT. PAVEMENT RESTORATION TRANSITION ON EACH SIDE OF | | | PROPOSED TRENCH PER CITY OF WPB STANDARD DETAIL GC-9. | | | | | | FEEL FREE TO CONTACT US IF YOU HAVE ANY QUESTIONS OR | | | CONCERNS, THANKS. | | | | | | RICK ROSSANO, PROJECT COORDINATOR | | | ENGINEERING SERVICES DEPARTMENT | | | DIRECT: (561) 494-1098 [email protected] | | | | | | |
|
|
| Review Stop |
ENG - PPRC |
ENGINEERING - PPRC |
| Rev No |
2 |
Status |
F |
Date |
12-04-2019 |
|
|
Cont ID |
|
| Sent By |
rrossano |
Date |
12-04-2019 |
Time |
|
Rev Time |
1.00 |
| Received By |
rrossano |
Date |
12-04-2019 |
Time |
|
Sent To |
|
|
| Notes |
| 2019-12-04 07:26:22 | REDESIGN WATER SYSTEM AS A PRIVATE SYSTEM WITH MASTER | | | METER. | | | | | | FEEL FREE TO CONTACT US IF YOU HAVE ANY QUESTIONS OR | | | CONCERNS, THANKS. | | | | | | RICK ROSSANO, PROJECT COORDINATOR | | | ENGINEERING SERVICES DEPARTMENT | | | 401 CLEMATIS STREET, 4TH FLOOR | | | WEST PALM BEACH, FL 33401 (MAILING ADDRESS: P.O. BOX | | | 3366, ZIP 33402) | | | MAIN PHONE: (561) 822-1200 DIRECT: (561) 494-1098 | | | FAX: (561) 494-1116 MOBILE: (561) 246-9525 | | | EMAIL: [email protected] | | | WWW.WPB.ORG/ENGINEERING | | | |
|
|
| Review Stop |
ENG - PPRC |
ENGINEERING - PPRC |
| Rev No |
1 |
Status |
P |
Date |
10-07-2019 |
|
|
Cont ID |
|
| Sent By |
rrossano |
Date |
10-07-2019 |
Time |
|
Rev Time |
|
| Received By |
rrossano |
Date |
10-07-2019 |
Time |
|
Sent To |
|
|
| Notes |
| 2019-10-07 12:11:34 | 1. THE CITY OF WEST PALM BEACH HAS A NUMBER OF | | | REGULATIONS AND PERMIT REQUIREMENTS WHICH DIRECTLY | | | AFFECT THE DEVELOPMENT AND INSTALLATION OF WATER AND | | | WASTEWATER UTILITIES WITHIN THE CITY. PLEASE SEE | | | DEVELOPMENT PERMIT SUBMITTAL REQUIREMENTS AT THE LINK | | | BELOW: HTTP://WPB.ORG/CMSPAGES/GETAMAZONFILE.ASPX?PATH= | | | ~\WPB_WEBSITE\MEDIA\ENGINEERING\DEVELOPMENT-APPLICATION | | | -FULL-PACKAGE_2016.PDF&HASH=7BD4DD7EB6115181D8C5977BCC0 | | | 2A97B1960045731D3658206F27451722716EF | | | THIS AND OTHER RELATED ENGINEERING DOCUMENTS CAN BE | | | FOUND HERE: HTTP://WPB.ORG/DEPARTMENTS/ENGINEERING-PUBL | | | IC-WORKS/FORMS,-PERMITS-APPLICATIONS | | | 2. CODE OF ORDINANCES, CITY OF WEST PALM BEACH, | | | FLORIDA, CODIFIED THROUGH ORD. NO. 4183-08, ADOPTED | | | SEPT. 22, 2008. (SUPPLEMENT NO. 18) | | | CHAPTER 90 UTILITIES, ARTICLE I. SEC. 90-7. | | | POLICY REGARDING EXTENSION OF WATER OR SEWER SERVICE | | | FACILITIES OF THE CITY. | | | THE WATER AND WASTEWATER SERVICE AGREEMENTS AND THE | | | CONSTRUCTION PERMITS ADDRESS RESERVATION OF CAPACITY | | | BASED ON USAGE, METER SIZE AND FEES, DESIGN STANDARDS, | | | BACKFLOW PREVENTION, FIRE SERVICE AND IRRIGATION. | | | 3. AS OF DECEMBER 20, 2015, THE CITY OF WEST PALM BEACH | | | CROSS-CONNECTION CONTROL MANUAL HAS BEEN REVISED, | | | STATING "ALL BACKFLOW DEVICES MUST BE LEAD-FREE". FOR | | | MORE INFORMATION, REFER TO THE LINK BELOW: | | | HTTP://WPB.ORG/DEPARTMENTS/PUBLIC-UTILITIES/FORMS-PUBLI | | | CATIONS/BACKFLOW-CROSS-CONNECTION-CONTROL-MANUAL | | | 4. PLANS SHALL SHOW PROPOSED LOCATIONS AND DIMENSIONS | | | OF ALL WATER, STORMWATER, AND SANITARY AND SEWER LINES, | | | INCLUDING STUBS TO EACH PROPERTY LINE FOR WATER AND | | | SANITARY SEWERS, THE MAKE AND MODEL OF ALL VALVES, | | | METERS, AND OTHERS DEVICES TO BE INSTALLED ON THE | | | SYSTEM, CATCH BASINS, CULVERTS, DITCHES INCLUDING | | | GRADES, PIPES SIZES, MATERIALS, ELEVATIONS, | | | ASSUMPTIONS, CALCULATIONS, INVERT ELEVATIONS FOR ALL | | | INLETS AND MANHOLES AND PROFILES OF SANITARY SEWER | | | LINES. ALL AVAILABLE ELEVATION SHALL BE SHOWN ON THE | | | PROFILE VIEW. DIRECTION OF FLOW SHALL BE SHOWN ON PLAN | | | VIEW ON PLAN VIEW FOR ALL SANITARY AND STORM SEWERS. | | | PLEASE SHOW SLOPE % ON ALL SANITARY LINES AND CALL OUT | | | MATERIAL. ADDITIONALLY, PLAN VIEW SHALL SHOW ALL | | | EXISTING AND PROPOSED UNDERGROUND UTILITY LAYOUT, | | | INCLUDING FIBER OPTIC, ELECTRIC, GAS, AND CABLEVISION & | | | TELECOMMUNICATION FACILITIES LOCATED ON THE | | | RIGHT-OF-WAY. PROVIDE PROFILE AND CLEARANCES AT ALL | | | UTILITY CROSSINGS. | | | 5. CUT AND CAP UTILITIES NOT IN USE, AND REMOVE ANY | | | ABANDONED UTILITY LINES LARGER THAN 2 INCHES FROM CITY | | | RIGHT OF WAY. | | | 6. PLEASE SUBMIT COMPLETED LOS ANALYSIS SUMMARY TABLE | | | DIRECTLY TO ENGINEERING (SHEET 33 OF CITY OF WPB | | | DEVELOPMENT APPLICATION). | | | 7. PROVIDE CALCULATIONS ON PLANS OF EXISTING AND | | | PROPOSED DEMANDS FOR WATER & SEWER (AVERAGE, MAXIMUM | | | AND PEAK) AND FIRE FLOW DEMANDS. CALCULATIONS SHALL BE | | | PER FAC 64E-6 FOR SEWER AND PER FAC 64-E.008 FOR WATER. | | | 8. SHOW VERTICAL DATUM AND DATUM CONVERSION INFORMATION | | | (NAVD 88 AND NGVD 29) ON ALL SHEETS. | | | 9. PLEASE PROVIDE CALCULATIONS OF EXISTING AND REVISED | | | PERVIOUS AND IMPERVIOUS CALCULATIONS FOR THE PROPOSED | | | IMPACTED AREAS. | | | 10. PROVIDE ONSITE CLEANOUTS NEAR PROPERTY LINE FOR | | | PROPOSED SANITARY LATERALS. | | | 11. COORDINATE WITH MARK HURLEY, FIELD CUSTOMER SERVICE | | | SUPERVISOR WITH CITY OF WPB PUBLIC UTILITIES, REGARDING | | | PLACEMENT OF BACKFLOW DEVICES AND WATER METERS. CONTACT | | | HIM AT 561-494-2262 OR [email protected] | | | 12. PROVIDE UTILITY EASEMENTS TO ALLOW ACCESS FOR CITY | | | PERSONNEL TO PROPOSED UTILITIES INCLUDING WATER METERS. | | | 13. PLEASE PROVIDE 10 FT. MIN. HORIZONTAL CLEARANCE | | | BETWEEN PROPOSED WATER AND SEWER LINES. | | | 14. PLEASE PROVIDE INLET ELEVATIONS AT PROPOSED | | | MANHOLES. | | | 15. SPECIFY WATER MAIN IN RIGHT OF WAY AS 8 IN. DIP | | | MATERIAL. | | | 16. PLEASE SHOW VALVE SIZES AND LOCATIONS. LABEL CITY | | | POINTS OF SERVICE. | | | 17. LABEL WATER LINES AS PRIVATE WHERE APPLICABLE. | | | 18. PLEASE CLEARLY SHOW LOCATION OF MASTER METER AND | | | VAULT. | | | 19. FOR FORMAL ENGINEERING SUBMITTAL, PROVIDE PROFILES | | | OF WATER AND SEWER AND SHOW ANY CROSSINGS/CONFLICTS. | | | 20. FOR FORMAL ENGINEERING SUBMITTAL, WHEN SUBMITTING | | | APPROVED MATERIALS LIST, PLEASE PROVIDE MATERIAL/CUT | | | SHEETS FOR ALL PROPOSED BACKFLOW DEVICES SHOWING | | | SPECIFIC MODEL NUMBER AND SPECIFYING USC APPROVED | | | LEAD-FREE DESIGN. | | | 21. FOR FORMAL ENGINEERING SUBMITTAL CLEARLY SHOW ROAD | | | RIGHT OF WAY. | | | 22. FOR FORMAL ENGINEERING SUBMITTAL PROVIDE SANITARY | | | ELEVATIONS AT MANHOLE TIE-IN. | | | 23. FOR FORMAL ENGINEERING SUBMITTAL, WHEN TRENCHING IN | | | IN CITY MAINTAINED ROADWAY AREAS ADD NOTE TO PROVIDE 50 | | | FT. PAVEMENT RESTORATION TRANSITION ON EACH SIDE OF | | | PROPOSED TRENCH PER CITY OF WPB STANDARD DETAIL GC-9. | | | 24. PLEASE RESPOND TO ALL COMMENTS IN WRITING AND | | | INCLUDE Z PERMIT NUMBER IN ALL CORRESPONDENCE. | | | ----------------------------- | | | PLEASE SEE ADDITIONAL COMMENTS FROM MARK HURLEY, | | | CUSTOMER SERVICE SUPERVISOR CITY OF WPB UTILITIES: | | | | | | BROADSTONE LAKESIDE (C-141) | | | PLAN IS CURRENTLY SETUP TO HAVE CITY WATER MAINS | | | TRAVELING THROUGHOUT PRIVATE COMMUNITY. IT NEEDS TO BE | | | COMPLETELY REWORKED SO THAT CITY POINT OF SERVICE IS | | | NEAR EDGE OF PROPERTY LINE AND MOST UTILITY EASEMENTS | | | ARE ELIMINATED. | | | NEW UTILITY PLAN SHOULD HAVE: | | | TWO DEDICATED ABOVE-GROUND LARGE DIAMETER METERS IN | | | SMALL U.E. -> CAN BE MADE TO LOOP WITH NO FIRE USE. | | | INDEPENDENT FIRE SYSTEM FED BY TWO DEDICATED FIRELINE | | | BACKFLOW ASSEMBLIES -> CAN BE LOOPED. IT SHOULD BE | | | LOCATED ADJACENT TO DOMESTIC BACKFLOW ASSEMBLIES. (ALL | | | BACKFLOW ASSEMBLIES ON PRIVATE PROPERTY OUT OF UE OR | | | ROW) | | | UTILITY METERS FOR WATER SHOULD BE IN A GRASSY AREA AND | | | NOT IN THE STREET WITH ACCESS FOR INSTALLING METER WITH | | | CRANE TRUCK. | | | MOST OF PIPE INSIDE PROPERTY SHOULD BE PRIVATELY OWNED | | | & MAINTAINED. | | | | | | MR. HURLEY CAN BE REACHED AT 561-494-2262 OR | | | [email protected] | | | | | | FEEL FREE TO CONTACT US IF YOU HAVE ANY QUESTIONS OR | | | CONCERNS, THANKS. | | | | | | RICK ROSSANO, PROJECT COORDINATOR, ENGINEERING SERVICES | | | DEPARTMENT | | | DIRECT: (561) 494-1098 [email protected] | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
10-04-2019 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
10-04-2019 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
10-04-2019 |
Time |
16:31 |
Sent To |
|
|
| Notes |
| 2019-10-04 16:37:13 | THE FOLLOWING COMMENTS WERE SUBMITTED BY PETER LEDUC, | | | FIRE MARSHAL, BUREAU OF FIRE PREVENTION, WEST PALM | | | BEACH FIRE RESCUE. | | | | | | THIS REVIEW CAN ONLY BE CONSIDERED PRELIMINARY AS THE | | | DRAWINGS THAT WERE REVIEWED WERE NOT COMPLETE. | | | ADDITIONAL COMMENTS CAN BE EXPECTED WHEN FULL DRAWINGS | | | ARE SUBMITTED FOR PERMIT. | | | | | | THE FIRE PREVENTION BUREAU HAS NO OBJECTIONS TO THE | | | PROPOSED PROJECT. | | | | | | 1. CONSTRUCTION, DEMOLITION, AND RENOVATION TO COMPLY | | | WITH NFPA 241. EXTRA ATTENTION SHALL BE GIVEN TO THE | | | PERMITTING AND LOCATION OF CONSTRUCTION TRAILERS. A | | | PERMIT IS REQUIRED FOR ANY CONSTRUCTION TRAILER RELATED | | | TO THIS PROJECT. SEPARATION DISTANCES FROM MAIN | | | STRUCTURES AS WELL AS OTHER TRAILERS SHALL BE CLOSELY | | | MONITORED FOR THE REQUIREMENTS OF FIRE SPRINKLER | | | PROTECTION. | | | | | | 2. SITE ACCESS AND EXIT POINTS ARE TO BE CLEARLY | | | IDENTIFIED AND MAINTAINED FOR EMERGENCY VEHICLES DURING | | | ALL CONSTRUCTION ACTIVITIES. | | | | | | 3. THE BUILDING ADDRESS SHALL BE CLEARLY VISIBLE FROM | | | ALL ACCESS ROADWAYS, INCLUDING DURING CONSTRUCTION. | | | ADDRESS NUMBERS SHALL CONTRAST WITH THEIR BACKGROUND | | | AND SHALL NOT BE LESS THAN SIX (6) INCHES IN HEIGHT | | | WITH A ONE (1) INCH STROKE FOR ALL BUILDINGS. | | | | | | 4. DURING CONSTRUCTION, TRASH AND DEBRIS IS TO BE | | | REMOVED FROM THE SITE DAILY OR MORE OFTEN TO REDUCE THE | | | ACCUMULATION OF POTENTIAL LIFE AND FIRE SAFETY HAZARDS. | | | | | | 5. THE CONSTRUCTION OF THE BUILDING SHALL COMPLY WITH | | | THE 6TH EDITION OF THE FLORIDA FIRE PREVENTION CODE, | | | INCLUDING NFPA 1 & 101, AND ALL ASSOCIATED FIRE CODES. | | | | | | 6. FOR PLAN REVIEW SUBMITTAL, PLEASE INCLUDE THE | | | OCCUPANCY TYPE, PER THE FLORIDA FIRE PREVENTION CODE, | | | AND WHETHER IT IS MIXED OR SEPARATED OCCUPANCY. | | | | | | 7. FOR PLAN REVIEW SUBMITTAL, PLEASE ENSURE THAT A FIRE | | | LOAD CALCULATION IS INCLUDED AND THAT ADEQUATE WATER | | | SUPPLY IS EXISTING OR WILL BE PROVIDED. | | | | | | 8. ALL EXISTING AND NEW FIRE HYDRANTS PLANNED FOR THIS | | | DEVELOPMENT SHALL BE CLEARLY INDICATED AND IDENTIFIED | | | ON THE PLAN AND CLOSELY COORDINATED WITH THE BUREAU OF | | | FIRE PREVENTION. | | | | | | ALL NEW FIRE HYDRANTS AND FDC?S PLANNED FOR THIS | | | DEVELOPMENT SHALL BE CLOSELY COORDINATED WITH THE | | | BUREAU OF FIRE PREVENTION. | | | | | | THE PROPOSED FIRE HYDRANTS AND FDC?S LOCATION ARE | | | ACCEPTABLE. | | | | | | 9. PROVIDE FOR A FIRE SPRINKLER AND/OR FIRE ALARM PER | | | THE APPLICABLE OCCUPANCY CODE. FOR ANY LIFE SAFETY | | | ENGINEERED SYSTEM, I.E FIRE SPRINKLER AND FIRE ALARM, | | | ENSURE THEY COMPLY WITH THE REQUIREMENTS OF FS 61G AND | | | SUBMITTED WITH THE MASTER PLAN. | | | | | | 9A) PROVIDE FOR THE REQUIRED STANDPIPE SYSTEM PER NFPA | | | 14. | | | | | | 10. COMPLETE LIFE SAFETY PLANS FOR EACH OCCUPANCY SHALL | | | BE PROVIDED THAT ILLUSTRATE OCCUPANT LOADS, TRAVEL | | | DISTANCES, COMMON PATHS OF TRAVEL, DEAD-END CORRIDORS, | | | EXIT SIGNS, EMERGENCY LIGHTING, EXITS LEADING TO A | | | PUBLIC WAY, FIRE EXTINGUISHER LOCATIONS, AND ALL FIRE | | | SAFETY FEATURES AND EQUIPMENT. | | | | | | 11. IT IS HIGHLY RECOMMENDED (REQUIRED WITH FIRE | | | SPRINKLER SYSTEM) THAT A KNOX BOX WITH KEYS FOR ENTRY | | | DOOR LOCKS BE PROVIDED FOR 24 HOUR EMERGENCY ACCESS. | | | | | | ANY PROPOSED GATES SHALL HAVE A KNOX KEY SWITCH SYSTEM | | | THAT OPERATE GATES TO OPEN TO A WIDTH EQUAL TO A 20' | | | FIRE LANE. | | | | | | 12. THE BUREAU'S APPROVAL OF THIS SUBMITTED PROJECT | | | DOES NOT CONSTITUTE ITS FINAL REVIEW OR APPROVAL. | | | | | | 13. THE BUREAU SHALL REVIEW ALL SUBMITTED BUILDING | | | PLANS AT THE APPROPRIATE TIME AND IN ACCORDANCE WITH | | | THE REQUIREMENTS OF ALL APPLICABLE CODES AND STANDARDS. | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | | | | |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
4 |
Status |
F |
Date |
02-27-2020 |
|
|
Cont ID |
|
| Sent By |
rcaranci |
Date |
02-27-2020 |
Time |
17:44 |
Rev Time |
0.00 |
| Received By |
rcaranci |
Date |
02-27-2020 |
Time |
17:44 |
Sent To |
|
|
| Notes |
| 2020-02-27 17:45:21 | FROM: RAY CARANCI, LANDSCAPE PLANNER 561-822-1462 | | | PROJECT: BROADSTONE LAKESIDE RPD | | | FEBRUARY 27, 2020 | | | FUTURE LAND USE MAP AMENDMENT Z19090014: NO COMMENTS. | | | REZONING TO RPD Z19090015 | | | I HAVE REVIEWED THE ABOVE REFERENCED PETITION, AND | | | PROVIDE THE FOLLOWING COMMENTS: | | | | | | 1. PROVIDE THE FOLLOWING CORRECTIONS TO THE TREE | | | DISPOSITION PLAN SHEET LD-1: | | | ? SATISFIED. BISCHOFIA IS ON THE PROHIBITED TREE LIST | | | AND THE FOUR LISTED DO NOT REQUIRE MITIGATION. | | | ? SATISFIED. CANOPY SQUARE FOOTAGE FOR MITIGATION DUE | | | FOR ANY TREES PROPOSED FOR REMOVAL MUST BE IN A | | | SEPARATE COLUMN, AND THE TOTAL PROVIDED FOR THE COLUMN. | | | SQUARE FOOTAGE FOR RELOCATED TREES IS NOT REQUIRED AND | | | MUST BE IN A SEPARATE COLUMN IF INCLUDED ON THE LIST. | | | ? SATISFIED. REMOVALS OF PALMS MUST INCLUDE THE | | | MITIGATION REQUIRED BY CATEGORY. ADONIDIA, FOXTAIL, | | | QUEEN PALM AND WASHINGTONIA PALM ARE ALL CATEGORY 4 | | | REQUIRING MITIGATION OF 50 SQ FT EACH. | | | ? SATISFIED. INCLUDE A CHART FOR TREE MITIGATION | | | PROVIDED BASED ON THE PLANT LIST AND PROVIDE THE TOTAL | | | FOR THE SQUARE FOOTAGE. | | | | | | 2. SATISFIED. SECTION 94-448 (D)(3) REQUIRES NATIVE | | | TREES IN GOOD CONDITION TO BE PRESERVED ON SITE OR | | | RELOCATED. A SIGNIFICANT NUMBER OF LIVE OAK TREES (26) | | | MANY OF LARGE CANOPY SIZE ARE LISTED TO BE REMOVED, AND | | | THE CONDITION LISTED AS FAIR. PROVIDE THE METHOD OF | | | DETERMINATION OF THE CONDITION ASSESSMENT, AND THE | | | SOURCE OF THE DETERMINATION. STAFF IS VERY FAMILIAR | | | WITH THE TREES ON SITE AND WILL MEET ON SITE WITH THE | | | LANDSCAPE ARCHITECT AND TREE RELOCATION CONTRACTOR TO | | | ASSESS THE CONDITION OF THE TREES LISTED AS FAIR. | | | | | | 3. SATISFIED. SHOW THE CALCULATIONS FOR MINIMUM SHADE | | | TREE AND FLOWERING TREE REQUIREMENTS PER SECTION | | | 94-443(C)(2)B. BASED ON OPEN SPACE AND ADD REQUIRED | | | TREES PER UNIT (280) TO ESTABLISH THE MINIMUM TREES | | | REQUIRED FOR THE SITE. OPEN SPACE REQUIRED FOR | | | RESIDENTIAL ZONING INCLUDES SETBACKS, PARKING, | | | SIDEWALKS, LANDSCAPE ISLANDS AND BUILDING PERIMETER | | | PLANTINGS. A SEPARATE OPEN SPACE PLAN MAY BE SUBMITTED | | | SHOWING THE OPEN SPACE AREAS COUNTED. | | | CALCULATIONS NEED TO BE CORRECTED TO SHOW TOTAL | | | NON-BUILDING OPEN SPACE AREA AND LAKE (WATER AREA | | | ONLY). SHOW THE LAKE AREA AND THE LAND AREA AT THE EDGE | | | OF THE SOUTHERN PORTION OF LAKE THAT CANNOT HAVE | | | LANDSCAPING DEDUCTED FROM THE OPEN SPACE FOR | | | CALCULATING THE REQUIRED TREES. SHOW THE TOTAL TREES | | | REQUIRED BASED ON THE REMAINDER AND CALCULATE THE | | | SHORTAGE OF REQUIRED TREES. THIS IS SHOWN AS 615 | | | REQUIRED AND 564 PROVIDED. THIS IS A DIFFERENCE OF 51 | | | TREES. | | | | | | INCLUDE ALL NON BUILDING AND NON LAKE AREA AS OPEN | | | SPACE. WHY IS THE SOUTHERN STRIP OF LAND NOT INCLUDED? | | | | | | | | | 4. SATISFIED. SHOW THE REQUIRED 10 FOOT LANDSCAPE | | | BUFFER ADJACENT TO THE RIGHT OF WAY AND THE 5 FOOT | | | LANDSCAPE BUFFER PLANTINGS ALONG ALL OTHER PROPERTY | | | LINES WITH THE REQUIRED TREES OR NUMBER OF SUBSTITUTE | | | PALMS PER CURRENT CODE REQUIREMENTS OF SECTION | | | 94-443(D). IF THE BUFFER CANNOT BE PROVIDED ALONG THE | | | PROPERTY LINE, A WAIVER MUST BE REQUESTED, AND | | | ALTERNATIVES PRESENTED TO PROVIDE COMPARABLE BUFFERING | | | ON THE SITE. | | | ALL REQUIRED LANDSCAPE BUFFERS MUST BE SHOWN, AND THE | | | AREAS INDICATED THAT ARE REQUESTED TO BE WAIVED. | | | QUANTIFY THE LINEAR MEASUREMENT OF REQUIRED AND | | | PROVIDED, AND WHAT IS BEING ASKED TO BE WAIVED. | | | | | | PROVIDE A SEPARATE EXHIBIT FOR CLARIFICATION. | | | | | | | | | 5. SATISFIED. INDICATE THE LANDSCAPE BUFFER LOCATIONS | | | ON THE SITE PLAN AND LANDSCAPE PLAN. PROVIDE A COMPLETE | | | SITE PLAN FOR THE SITE. SHEET SP-1 DOES NOT SHOW THE | | | ENTIRE SITE. SHEET EPH-1 SHOWS BOTH SITES, SO THE SITE | | | PLAN SHOULD SHOW ALL OF THE RPD. | | | PROVIDE A COMPLETE LANDSCAPE PLAN FOR THE SITE MATCHING | | | THE SITE PLAN. SOUTHERN PORTION OF THE SITE NEEDS TO BE | | | SHOWN. | | | | | | 6. SATISFIED. SHOW ALL CALCULATIONS FOR THE REQUIRED | | | TREES FOR BUFFER SEGMENTS ON A PERIMETER BUFFER | | | REQUIREMENT CHART INCLUDING LINEAR FOOTAGE OF ALL | | | PROPERTY LINE SEGMENTS. | | | BUFFER SEGMENT ADJACENT TO THE ROAD NEEDS TO BE LISTED | | | SEPARATELY, AS THIS HAS A REQUIRED 10 FOOT BUFFER. | | | BUFFER SEGMENTS NEED TO BE DIVIDED AND SHOWN AS VILLAGE | | | BLVD., WEST (ADJACENT TO CANAL), NORTH (ALL SEGMENTS), | | | AND EAST (ALONG I 95). SHOW TOTAL BUFFER LENGTH AND | | | DIVIDE BY 30, ROUND UP TO THE NEXT FULL TREE AND SHOW | | | THE REQUIRED NUMBER OF TREES, THE NUMBER PROVIDED, AND | | | THE NUMBER REQUESTED TO BE WAIVED FOR THAT SEGMENT. | | | THE CHART NEEDS TO BE COMPLETED WITH THE REQUIRED AND | | | PROVIDED BUFFER AND TREE BROKEN DOWN BY SEGMENTS. | | | | | | | | | | | | 7. SATISFIED. PROVIDE CALCULATIONS FOR ALL BUFFERS | | | ALONG VILLAGE BOULEVARD WITH ACCESS DRIVEWAYS TO SHOW | | | THEY DO NOT EXCEED 25% INTERRUPTION FOR VEHICULAR | | | ACCESS AS REQUIRED BY SECTION 94-443(B)(2). | | | | | | 8. SATISFIED. SUBSTITUTION OF PALMS FOR TREES REQUIRES | | | 3:1 RATIO FOR SABAL PALMS AND MONTGOMERY PALMS. ADD UP | | | ALL TRUNKS AT 3:1 AND THEN DIVIDE BY 3 TO GET TREE | | | COUNT AND ADD ROYALS AND MEDJOOLS AS 1:1 PALMS. | | | RECALCULATE TREES COUNT PROVIDED. | | | | | | 9. SATISFIED. LIGUSTRUM DOES NOT QUALIFY AS A TREE | | | UNLESS PROVIDED AT 12 FOOT MINIMUM SIZE AND PLACED TO | | | BE ALLOWED TO GROW TO HEIGHT AND SPREAD MEETING THE | | | TREE DEFINITION. | | | | | | 10. SATISFIED. MODIFY THE PLANT LIST TO ADD COLUMNS FOR | | | NATIVE PLANT AND DROUGHT TOLERANCE LEVELS TO PROVIDE | | | EASIER REFERENCE. | | | | | | 11. SATISFIED. ADD RELOCATED TREES TO THE PLANT LIST | | | AND COUNT THEM TOWARD THE REQUIRED TREES. | | | LIST SPECIES AND QUANTITIES OF EACH. | | | LIST LIVE OAKS AND SABAL PALMS SEPARATELY. | | | | | | 12. SATISFIED. SECTION 94-443(C)(3) REQUIRES THAT A | | | MINIMUM OF 75 PERCENT OF ALL TREES THAT ARE REQUIRED TO | | | BE PLANTED WITHIN THE INTERIOR OF AN OFF STREET PARKING | | | AREA SHALL BE CATEGORY 1 SHADE TREES. SHOW THE | | | PERCENTAGE OF CATEGORY 1 TREES PROVIDED FOR THE | | | REQUIRED LANDSCAPE AREAS. | | | | | | 13. SATISFIED. PROVIDE AN EXHIBIT SHOWING THE PARKING | | | AREA SURFACE CALCULATIONS, PARKING SPACE AREAS AND | | | LANDSCAPE AREAS PROVIDED TO DEMONSTRATE COMPLIANCE WITH | | | SECTIONS 94-443 (C)(3) AND (4). | | | LIST THE CALCULATIONS ON THE DATA CHART. | | | PROVIDE AS A LARGER 1:20 SCALE PLAN FOR REVIEW OF THE | | | PROVIDED AREAS. | | | | | | | | | 14. SATISFIED. SHOW ALL REQUIRED CURBS ADJACENT TO | | | LANDSCAPE AREAS PER SECTION 94-443 (C)(5). THERE APPEAR | | | TO BE AREAS THAT ARE NOT CURBED. LANDSCAPE DIVIDER | | | STRIPS CAN HAVE CURBS INSTEAD OF WHEEL STOPS TO | | | INCREASE THE LANDSCAPE AREA FOR THE TREES. IF DRAINAGE | | | IS A CONCERN, THEY CAN BE DESIGNED TO ROUTE WATER INTO | | | THE LANDSCAPE AREAS. | | | | | | 15. SATISFIED. UPDATE THE FLORIDA FRIENDLY LANDSCAPE | | | CHART TO THE CURRENT CODE AND PROVIDE THE MINIMUM 50 | | | POINTS BASED ON THE PLANT LIST AND ITEMS THAT QUALIFY. | | | SOME WORDING AND PERCENTAGES ARE NOT CORRECT. | | | | | | 16. SATISFIED. PROVIDE LOCATIONS OF LIGHTING ON THE | | | LANDSCAPE PLAN TO AVOID CONFLICTS WITH LANDSCAPING. | | | | | | 17. SATISFIED. THERE APPEAR TO BE CONFLICTS IN SEVERAL | | | LOCATIONS BETWEEN TREES AND WATER AND SEWER LINES ON | | | THE LANDSCAPE PLAN. ADJUST LOCATIONS OF TREES OR | | | UTILITY LINES TO RESOLVE CONFLICTS WITH LANDSCAPING. | | | FDC LOCATIONS NEED TO BE CHANGED TO AVOID TAKING SPACE | | | IN LANDSCAPE ISLANDS INTENDED FOR REQUIRED TREES. | | | | | | THERE ARE MULTIPLE EXAMPLES OF REQUIRED TREES BEING | | | DISPLACED FOR FIRE HYDRANTS AND FDC CONNECTIONS. | | | COORDINATE WITH THE ENGINEER TO RELOCATE TO ALLOW THE | | | REQUIRED SPACE FOR TREES TO BE AVAILABLE. | | | . | | | 18. SATISFIED. PROVIDE LOCATIONS AND SCREENING FOR ALL | | | ABOVE GROUND UTILITY VALVES, BACKFLOW PREVENTERS, A/C | | | UNITS, AND FPL TRANSFORMERS. | | | | | | 19. SATISFIED. SHOW LOCATIONS OF ANY ROOT BARRIERS | | | REQUIRED TO PROTECT UTILITY LINES AND PROVIDE A ROOT | | | BARRIER DETAIL. | | | SEE COMMENT #17 ABOVE. NON HERBICIDE HARD PLASTIC ROOT | | | BARRIER IS PREFERRED OVER BIO BARRIER. | | | | | | 20. SATISFIED. SHOW COMPLIANCE WITH SECTION 94-445 L. | | | PLANT SPECIES. A MINIMUM OF 60 PERCENT OF PLANT | | | MATERIAL ADDED SHALL BE FLORIDA NATIVE OR DROUGHT | | | TOLERANT SPECIES SELECTED FROM THE CITY LIST OR THE | | | LIST OF SPECIES IN THE MOST RECENT EDITION OF SOUTH | | | FLORIDA WATER MANAGEMENT DISTRICT WATERWISE SOUTH | | | FLORIDA LANDSCAPES. | | | PERCENTAGE COULD NOT BE LOCATED ON SHEET LP-8. | | | | | | PROVIDE THE ACTUAL PERCENTAGE BASED ON THE PLANT LIST | | | OF ADDED PLANTS. | | | | | | 21. SATISFIED. THE LAKE AREA EXPANSION MUST INCLUDE | | | LITTORAL PLANTINGS PER SECTION 94-450. | | | TOTAL LINEAR FOOTAGE OF THE ENTIRE LAKE BANK MUST BE | | | PROVIDED, AND 50 PERCENT INDICATED, THEN WHAT IS BEING | | | PROVIDED. | | | THIS NEEDS TO BE CLARIFIED ON THE PLAN AND IN THE | | | WAIVER. | | | ADDITIONAL COMMENTS 12/9/19: | | | | | | 22. SATISFIED. THERE ARE EXISTING TREES AND PALMS | | | WITHIN THE PROPERTY OUTSIDE OF THE AREA SHOWN ON SHEET | | | LD-1. PROVIDE THE REQUIRED INFORMATION AND INCLUDE THEM | | | ON THE TREE DISPOSITION PLAN AND LIST. | | | | | | 23. SATISFIED. CORRECT THE MITIGATION VALUES ON SHEET | | | LP-1 FOR ROYAL PALM AND SABAL PALM TO CATEGORY 3 AT 100 | | | SQUARE FEET MITIGATION CREDIT.FOR | | | ADDITIONAL COMMENTS 1-21-20 | | | 24. PARTIALLY SATISFIED. LAKE BANK CROSS SECTIONS SHEET | | | C-137 NEEDS TO INCLUDE ANY MODIFICATIONS FOR LITTORAL | | | PLANTING AREAS, AND A CROSS SECTION DETAIL IS NEEDED | | | FOR THE PLANTING. | | | SHOW SPECIFIC PLANTING ZONES REQUIRED FOR THE PLANT | | | SPECIES SELECTED. A LITTORAL SHELF MAY BE REQUIRED TO | | | PROVIDE THE CORRECT WATER DEPTH FOR THE SELECTED | | | SPECIES. | | | | | | | | | 25. SATISFIED. A DETAIL IS SHOWN FOR ARTIFICIAL TURF, | | | BUT THE AREAS PROPOSED ARE NOT SHOWN ON THE LANDSCAPE | | | PLAN. PER CODE THESE AREAS MUST BE COUNTED AS | | | IMPERVIOUS AREA. | | | ADDITIONAL COMMENTS 2-27-20: | | | 26. HEDGE IS REQUIRED ON 3 SIDES OF ALL DUMPSTER | | | ENCLOSURES. ENCLOSURE ADJACENT TO THE LIFT STATION | | | REQUIRES A HEDGE ON THE NORTH SIDE. | | | | | | CONDITIONS OF APPROVAL | | | 1. PRIOR TO THE REMOVAL OR RELOCATION OF ANY TREES ON | | | THE PROPERTY, A TREE ALTERATION PERMIT SHALL BE | | | SUBMITTED, REVIEWED AND APPROVED BY THE DEVELOPMENT | | | SERVICES DEPARTMENT, PLANNING DIVISION. | | | |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
3 |
Status |
F |
Date |
01-22-2020 |
|
|
Cont ID |
|
| Sent By |
rcaranci |
Date |
01-22-2020 |
Time |
12:54 |
Rev Time |
0.00 |
| Received By |
rcaranci |
Date |
01-22-2020 |
Time |
12:54 |
Sent To |
|
|
| Notes |
| 2020-01-22 12:54:49 | FROM: RAY CARANCI, LANDSCAPE PLANNER 561-822-1462 | | | PROJECT: BROADSTONE LAKESIDE RPD | | | JANUARY 21, 2020 | | | FUTURE LAND USE MAP AMENDMENT Z19090014: NO COMMENTS. | | | REZONING TO RPD Z19090015 | | | I HAVE REVIEWED THE ABOVE REFERENCED PETITION, AND | | | PROVIDE THE FOLLOWING COMMENTS: | | | | | | 1. PROVIDE THE FOLLOWING CORRECTIONS TO THE TREE | | | DISPOSITION PLAN SHEET LD-1: | | | ? SATISFIED. BISCHOFIA IS ON THE PROHIBITED TREE LIST | | | AND THE FOUR LISTED DO NOT REQUIRE MITIGATION. | | | ? SATISFIED. CANOPY SQUARE FOOTAGE FOR MITIGATION DUE | | | FOR ANY TREES PROPOSED FOR REMOVAL MUST BE IN A | | | SEPARATE COLUMN, AND THE TOTAL PROVIDED FOR THE COLUMN. | | | SQUARE FOOTAGE FOR RELOCATED TREES IS NOT REQUIRED AND | | | MUST BE IN A SEPARATE COLUMN IF INCLUDED ON THE LIST. | | | ? SATISFIED. REMOVALS OF PALMS MUST INCLUDE THE | | | MITIGATION REQUIRED BY CATEGORY. ADONIDIA, FOXTAIL, | | | QUEEN PALM AND WASHINGTONIA PALM ARE ALL CATEGORY 4 | | | REQUIRING MITIGATION OF 50 SQ FT EACH. | | | ? SATISFIED. INCLUDE A CHART FOR TREE MITIGATION | | | PROVIDED BASED ON THE PLANT LIST AND PROVIDE THE TOTAL | | | FOR THE SQUARE FOOTAGE. | | | | | | 2. SATISFIED. SECTION 94-448 (D)(3) REQUIRES NATIVE | | | TREES IN GOOD CONDITION TO BE PRESERVED ON SITE OR | | | RELOCATED. A SIGNIFICANT NUMBER OF LIVE OAK TREES (26) | | | MANY OF LARGE CANOPY SIZE ARE LISTED TO BE REMOVED, AND | | | THE CONDITION LISTED AS FAIR. PROVIDE THE METHOD OF | | | DETERMINATION OF THE CONDITION ASSESSMENT, AND THE | | | SOURCE OF THE DETERMINATION. STAFF IS VERY FAMILIAR | | | WITH THE TREES ON SITE AND WILL MEET ON SITE WITH THE | | | LANDSCAPE ARCHITECT AND TREE RELOCATION CONTRACTOR TO | | | ASSESS THE CONDITION OF THE TREES LISTED AS FAIR. | | | | | | 3. PARTIALLY SATISFIED. SHOW THE CALCULATIONS FOR | | | MINIMUM SHADE TREE AND FLOWERING TREE REQUIREMENTS PER | | | SECTION 94-443(C)(2)B. BASED ON OPEN SPACE AND ADD | | | REQUIRED TREES PER UNIT (280) TO ESTABLISH THE MINIMUM | | | TREES REQUIRED FOR THE SITE. OPEN SPACE REQUIRED FOR | | | RESIDENTIAL ZONING INCLUDES SETBACKS, PARKING, | | | SIDEWALKS, LANDSCAPE ISLANDS AND BUILDING PERIMETER | | | PLANTINGS. A SEPARATE OPEN SPACE PLAN MAY BE SUBMITTED | | | SHOWING THE OPEN SPACE AREAS COUNTED. | | | CALCULATIONS NEED TO BE CORRECTED TO SHOW TOTAL | | | NON-BUILDING OPEN SPACE AREA AND LAKE (WATER AREA | | | ONLY). SHOW THE LAKE AREA AND THE LAND AREA AT THE EDGE | | | OF THE SOUTHERN PORTION OF LAKE THAT CANNOT HAVE | | | LANDSCAPING DEDUCTED FROM THE OPEN SPACE FOR | | | CALCULATING THE REQUIRED TREES. SHOW THE TOTAL TREES | | | REQUIRED BASED ON THE REMAINDER AND CALCULATE THE | | | SHORTAGE OF REQUIRED TREES. THIS IS SHOWN AS 615 | | | REQUIRED AND 564 PROVIDED. THIS IS A DIFFERENCE OF 51 | | | TREES. | | | | | | INCLUDE ALL NON BUILDING AND NON LAKE AREA AS OPEN | | | SPACE. WHY IS THE SOUTHERN STRIP OF LAND NOT INCLUDED? | | | | | | | | | 4. PARTIALLY SATISFIED. SHOW THE REQUIRED 10 FOOT | | | LANDSCAPE BUFFER ADJACENT TO THE RIGHT OF WAY AND THE 5 | | | FOOT LANDSCAPE BUFFER PLANTINGS ALONG ALL OTHER | | | PROPERTY LINES WITH THE REQUIRED TREES OR NUMBER OF | | | SUBSTITUTE PALMS PER CURRENT CODE REQUIREMENTS OF | | | SECTION 94-443(D). IF THE BUFFER CANNOT BE PROVIDED | | | ALONG THE PROPERTY LINE, A WAIVER MUST BE REQUESTED, | | | AND ALTERNATIVES PRESENTED TO PROVIDE COMPARABLE | | | BUFFERING ON THE SITE. | | | ALL REQUIRED LANDSCAPE BUFFERS MUST BE SHOWN, AND THE | | | AREAS INDICATED THAT ARE REQUESTED TO BE WAIVED. | | | QUANTIFY THE LINEAR MEASUREMENT OF REQUIRED AND | | | PROVIDED, AND WHAT IS BEING ASKED TO BE WAIVED. | | | | | | PROVIDE A SEPARATE EXHIBIT FOR CLARIFICATION. | | | | | | | | | 5. SATISFIED. INDICATE THE LANDSCAPE BUFFER LOCATIONS | | | ON THE SITE PLAN AND LANDSCAPE PLAN. PROVIDE A COMPLETE | | | SITE PLAN FOR THE SITE. SHEET SP-1 DOES NOT SHOW THE | | | ENTIRE SITE. SHEET EPH-1 SHOWS BOTH SITES, SO THE SITE | | | PLAN SHOULD SHOW ALL OF THE RPD. | | | PROVIDE A COMPLETE LANDSCAPE PLAN FOR THE SITE MATCHING | | | THE SITE PLAN. SOUTHERN PORTION OF THE SITE NEEDS TO BE | | | SHOWN. | | | | | | 6. PARTIALLY SATISFIED. SHOW ALL CALCULATIONS FOR THE | | | REQUIRED TREES FOR BUFFER SEGMENTS ON A PERIMETER | | | BUFFER REQUIREMENT CHART INCLUDING LINEAR FOOTAGE OF | | | ALL PROPERTY LINE SEGMENTS. | | | BUFFER SEGMENT ADJACENT TO THE ROAD NEEDS TO BE LISTED | | | SEPARATELY, AS THIS HAS A REQUIRED 10 FOOT BUFFER. | | | BUFFER SEGMENTS NEED TO BE DIVIDED AND SHOWN AS VILLAGE | | | BLVD., WEST (ADJACENT TO CANAL), NORTH (ALL SEGMENTS), | | | AND EAST (ALONG I 95). SHOW TOTAL BUFFER LENGTH AND | | | DIVIDE BY 30, ROUND UP TO THE NEXT FULL TREE AND SHOW | | | THE REQUIRED NUMBER OF TREES, THE NUMBER PROVIDED, AND | | | THE NUMBER REQUESTED TO BE WAIVED FOR THAT SEGMENT. | | | THE CHART NEEDS TO BE COMPLETED WITH THE REQUIRED AND | | | PROVIDED BUFFER AND TREE BROKEN DOWN BY SEGMENTS. | | | | | | | | | | | | 7. SATISFIED. PROVIDE CALCULATIONS FOR ALL BUFFERS | | | ALONG VILLAGE BOULEVARD WITH ACCESS DRIVEWAYS TO SHOW | | | THEY DO NOT EXCEED 25% INTERRUPTION FOR VEHICULAR | | | ACCESS AS REQUIRED BY SECTION 94-443(B)(2). | | | | | | 8. SATISFIED. SUBSTITUTION OF PALMS FOR TREES REQUIRES | | | 3:1 RATIO FOR SABAL PALMS AND MONTGOMERY PALMS. ADD UP | | | ALL TRUNKS AT 3:1 AND THEN DIVIDE BY 3 TO GET TREE | | | COUNT AND ADD ROYALS AND MEDJOOLS AS 1:1 PALMS. | | | RECALCULATE TREES COUNT PROVIDED. | | | | | | 9. SATISFIED. LIGUSTRUM DOES NOT QUALIFY AS A TREE | | | UNLESS PROVIDED AT 12 FOOT MINIMUM SIZE AND PLACED TO | | | BE ALLOWED TO GROW TO HEIGHT AND SPREAD MEETING THE | | | TREE DEFINITION. | | | | | | 10. SATISFIED. MODIFY THE PLANT LIST TO ADD COLUMNS FOR | | | NATIVE PLANT AND DROUGHT TOLERANCE LEVELS TO PROVIDE | | | EASIER REFERENCE. | | | | | | 11. PARTIALLY SATISFIED. ADD RELOCATED TREES TO THE | | | PLANT LIST AND COUNT THEM TOWARD THE REQUIRED TREES. | | | LIST SPECIES AND QUANTITIES OF EACH. | | | LIST LIVE OAKS AND SABAL PALMS SEPARATELY. | | | | | | 12. SATISFIED. SECTION 94-443(C)(3) REQUIRES THAT A | | | MINIMUM OF 75 PERCENT OF ALL TREES THAT ARE REQUIRED TO | | | BE PLANTED WITHIN THE INTERIOR OF AN OFF STREET PARKING | | | AREA SHALL BE CATEGORY 1 SHADE TREES. SHOW THE | | | PERCENTAGE OF CATEGORY 1 TREES PROVIDED FOR THE | | | REQUIRED LANDSCAPE AREAS. | | | | | | 13. SATISFIED. PROVIDE AN EXHIBIT SHOWING THE PARKING | | | AREA SURFACE CALCULATIONS, PARKING SPACE AREAS AND | | | LANDSCAPE AREAS PROVIDED TO DEMONSTRATE COMPLIANCE WITH | | | SECTIONS 94-443 (C)(3) AND (4). | | | LIST THE CALCULATIONS ON THE DATA CHART. | | | PROVIDE AS A LARGER 1:20 SCALE PLAN FOR REVIEW OF THE | | | PROVIDED AREAS. | | | | | | | | | 14. SATISFIED. SHOW ALL REQUIRED CURBS ADJACENT TO | | | LANDSCAPE AREAS PER SECTION 94-443 (C)(5). THERE APPEAR | | | TO BE AREAS THAT ARE NOT CURBED. LANDSCAPE DIVIDER | | | STRIPS CAN HAVE CURBS INSTEAD OF WHEEL STOPS TO | | | INCREASE THE LANDSCAPE AREA FOR THE TREES. IF DRAINAGE | | | IS A CONCERN, THEY CAN BE DESIGNED TO ROUTE WATER INTO | | | THE LANDSCAPE AREAS. | | | | | | 15. SATISFIED. UPDATE THE FLORIDA FRIENDLY LANDSCAPE | | | CHART TO THE CURRENT CODE AND PROVIDE THE MINIMUM 50 | | | POINTS BASED ON THE PLANT LIST AND ITEMS THAT QUALIFY. | | | SOME WORDING AND PERCENTAGES ARE NOT CORRECT. | | | | | | 16. SATISFIED. PROVIDE LOCATIONS OF LIGHTING ON THE | | | LANDSCAPE PLAN TO AVOID CONFLICTS WITH LANDSCAPING. | | | | | | 17. PARTIALLY SATISFIED. THERE APPEAR TO BE CONFLICTS | | | IN SEVERAL LOCATIONS BETWEEN TREES AND WATER AND SEWER | | | LINES ON THE LANDSCAPE PLAN. ADJUST LOCATIONS OF TREES | | | OR UTILITY LINES TO RESOLVE CONFLICTS WITH LANDSCAPING. | | | FDC LOCATIONS NEED TO BE CHANGED TO AVOID TAKING SPACE | | | IN LANDSCAPE ISLANDS INTENDED FOR REQUIRED TREES. | | | | | | THERE ARE MULTIPLE EXAMPLES OF REQUIRED TREES BEING | | | DISPLACED FOR FIRE HYDRANTS AND FDC CONNECTIONS. | | | COORDINATE WITH THE ENGINEER TO RELOCATE TO ALLOW THE | | | REQUIRED SPACE FOR TREES TO BE AVAILABLE. | | | . | | | 18. SATISFIED. PROVIDE LOCATIONS AND SCREENING FOR ALL | | | ABOVE GROUND UTILITY VALVES, BACKFLOW PREVENTERS, A/C | | | UNITS, AND FPL TRANSFORMERS. | | | | | | 19. SATISFIED. SHOW LOCATIONS OF ANY ROOT BARRIERS | | | REQUIRED TO PROTECT UTILITY LINES AND PROVIDE A ROOT | | | BARRIER DETAIL. | | | SEE COMMENT #17 ABOVE. NON HERBICIDE HARD PLASTIC ROOT | | | BARRIER IS PREFERRED OVER BIO BARRIER. | | | | | | 20. PARTIALLY SATISFIED. SHOW COMPLIANCE WITH SECTION | | | 94-445 L. PLANT SPECIES. A MINIMUM OF 60 PERCENT OF | | | PLANT MATERIAL ADDED SHALL BE FLORIDA NATIVE OR DROUGHT | | | TOLERANT SPECIES SELECTED FROM THE CITY LIST OR THE | | | LIST OF SPECIES IN THE MOST RECENT EDITION OF SOUTH | | | FLORIDA WATER MANAGEMENT DISTRICT WATERWISE SOUTH | | | FLORIDA LANDSCAPES. | | | PERCENTAGE COULD NOT BE LOCATED ON SHEET LP-8. | | | | | | PROVIDE THE ACTUAL PERCENTAGE BASED ON THE PLANT LIST | | | OF ADDED PLANTS. | | | | | | 21. PARTIALLY SATISFIED. THE LAKE AREA EXPANSION MUST | | | INCLUDE LITTORAL PLANTINGS PER SECTION 94-450. | | | TOTAL LINEAR FOOTAGE OF THE ENTIRE LAKE BANK MUST BE | | | PROVIDED, AND 50 PERCENT INDICATED, THEN WHAT IS BEING | | | PROVIDED. | | | THIS NEEDS TO BE CLARIFIED ON THE PLAN AND IN THE | | | WAIVER. | | | ADDITIONAL COMMENTS 12/9/19: | | | | | | 22. SATISFIED. THERE ARE EXISTING TREES AND PALMS | | | WITHIN THE PROPERTY OUTSIDE OF THE AREA SHOWN ON SHEET | | | LD-1. PROVIDE THE REQUIRED INFORMATION AND INCLUDE THEM | | | ON THE TREE DISPOSITION PLAN AND LIST. | | | | | | 23. SATISFIED. CORRECT THE MITIGATION VALUES ON SHEET | | | LP-1 FOR ROYAL PALM AND SABAL PALM TO CATEGORY 3 AT 100 | | | SQUARE FEET MITIGATION CREDIT.FOR | | | ADDITIONAL COMMENTS 1-21-20 | | | 24. LAKE BANK CROSS SECTIONS SHEET C-137 NEEDS TO | | | INCLUDE ANY MODIFICATIONS FOR LITTORAL PLANTING AREAS, | | | AND A CROSS SECTION DETAIL IS NEEDED FOR THE PLANTING. | | | | | | 25. A DETAIL IS SHOWN FOR ARTIFICIAL TURF, BUT THE | | | AREAS PROPOSED ARE NOT SHOWN ON THE LANDSCAPE PLAN. PER | | | CODE THESE AREAS MUST BE COUNTED AS IMPERVIOUS AREA. | | | | | | CONDITIONS OF APPROVAL | | | 1. PRIOR TO THE REMOVAL OR RELOCATION OF ANY TREES ON | | | THE PROPERTY, A TREE ALTERATION PERMIT SHALL BE | | | SUBMITTED, REVIEWED AND APPROVED BY THE DEVELOPMENT | | | SERVICES DEPARTMENT, PLANNING DIVISION. | | | |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
2 |
Status |
F |
Date |
12-09-2019 |
|
|
Cont ID |
|
| Sent By |
rcaranci |
Date |
12-09-2019 |
Time |
16:50 |
Rev Time |
0.00 |
| Received By |
rcaranci |
Date |
12-09-2019 |
Time |
16:50 |
Sent To |
|
|
| Notes |
| 2019-12-09 16:51:21 | FROM: RAY CARANCI, LANDSCAPE PLANNER 561-822-1462 | | | PROJECT: BROADSTONE LAKESIDE RPD | | | DECEMBER 9, 2019 | | | FUTURE LAND USE MAP AMENDMENT Z19090014: NO COMMENTS. | | | REZONING TO RPD Z19090015 | | | I HAVE REVIEWED THE ABOVE REFERENCED PETITION, AND | | | PROVIDE THE FOLLOWING COMMENTS: | | | | | | 1. PROVIDE THE FOLLOWING CORRECTIONS TO THE TREE | | | DISPOSITION PLAN SHEET LD-1: | | | ? SATISFIED. BISCHOFIA IS ON THE PROHIBITED TREE LIST | | | AND THE FOUR LISTED DO NOT REQUIRE MITIGATION. | | | ? SATISFIED. CANOPY SQUARE FOOTAGE FOR MITIGATION DUE | | | FOR ANY TREES PROPOSED FOR REMOVAL MUST BE IN A | | | SEPARATE COLUMN, AND THE TOTAL PROVIDED FOR THE COLUMN. | | | SQUARE FOOTAGE FOR RELOCATED TREES IS NOT REQUIRED AND | | | MUST BE IN A SEPARATE COLUMN IF INCLUDED ON THE LIST. | | | ? SATISFIED. REMOVALS OF PALMS MUST INCLUDE THE | | | MITIGATION REQUIRED BY CATEGORY. ADONIDIA, FOXTAIL, | | | QUEEN PALM AND WASHINGTONIA PALM ARE ALL CATEGORY 4 | | | REQUIRING MITIGATION OF 50 SQ FT EACH. | | | ? SATISFIED. INCLUDE A CHART FOR TREE MITIGATION | | | PROVIDED BASED ON THE PLANT LIST AND PROVIDE THE TOTAL | | | FOR THE SQUARE FOOTAGE. | | | | | | 2. SATISFIED. SECTION 94-448 (D)(3) REQUIRES NATIVE | | | TREES IN GOOD CONDITION TO BE PRESERVED ON SITE OR | | | RELOCATED. A SIGNIFICANT NUMBER OF LIVE OAK TREES (26) | | | MANY OF LARGE CANOPY SIZE ARE LISTED TO BE REMOVED, AND | | | THE CONDITION LISTED AS FAIR. PROVIDE THE METHOD OF | | | DETERMINATION OF THE CONDITION ASSESSMENT, AND THE | | | SOURCE OF THE DETERMINATION. STAFF IS VERY FAMILIAR | | | WITH THE TREES ON SITE AND WILL MEET ON SITE WITH THE | | | LANDSCAPE ARCHITECT AND TREE RELOCATION CONTRACTOR TO | | | ASSESS THE CONDITION OF THE TREES LISTED AS FAIR. | | | | | | 3. PARTIALLY SATISFIED. SHOW THE CALCULATIONS FOR | | | MINIMUM SHADE TREE AND FLOWERING TREE REQUIREMENTS PER | | | SECTION 94-443(C)(2)B. BASED ON OPEN SPACE AND ADD | | | REQUIRED TREES PER UNIT (280) TO ESTABLISH THE MINIMUM | | | TREES REQUIRED FOR THE SITE. OPEN SPACE REQUIRED FOR | | | RESIDENTIAL ZONING INCLUDES SETBACKS, PARKING, | | | SIDEWALKS, LANDSCAPE ISLANDS AND BUILDING PERIMETER | | | PLANTINGS. A SEPARATE OPEN SPACE PLAN MAY BE SUBMITTED | | | SHOWING THE OPEN SPACE AREAS COUNTED. | | | CALCULATIONS NEED TO BE CORRECTED TO SHOW TOTAL | | | NON-BUILDING OPEN SPACE AREA AND LAKE (WATER AREA | | | ONLY). SHOW THE LAKE AREA AND THE LAND AREA AT THE EDGE | | | OF THE SOUTHERN PORTION OF LAKE THAT CANNOT HAVE | | | LANDSCAPING DEDUCTED FROM THE OPEN SPACE FOR | | | CALCULATING THE REQUIRED TREES. SHOW THE TOTAL TREES | | | REQUIRED BASED ON THE REMAINDER AND CALCULATE THE | | | SHORTAGE OF REQUIRED TREES. THIS IS SHOWN AS 615 | | | REQUIRED AND 564 PROVIDED. THIS IS A DIFFERENCE OF 51 | | | TREES. | | | | | | | | | 4. PARTIALLY SATISFIED. SHOW THE REQUIRED 10 FOOT | | | LANDSCAPE BUFFER ADJACENT TO THE RIGHT OF WAY AND THE 5 | | | FOOT LANDSCAPE BUFFER PLANTINGS ALONG ALL OTHER | | | PROPERTY LINES WITH THE REQUIRED TREES OR NUMBER OF | | | SUBSTITUTE PALMS PER CURRENT CODE REQUIREMENTS OF | | | SECTION 94-443(D). IF THE BUFFER CANNOT BE PROVIDED | | | ALONG THE PROPERTY LINE, A WAIVER MUST BE REQUESTED, | | | AND ALTERNATIVES PRESENTED TO PROVIDE COMPARABLE | | | BUFFERING ON THE SITE. | | | ALL REQUIRED LANDSCAPE BUFFERS MUST BE SHOWN, AND THE | | | AREAS INDICATED THAT ARE REQUESTED TO BE WAIVED. | | | QUANTIFY THE LINEAR MEASUREMENT OF REQUIRED AND | | | PROVIDED, AND WHAT IS BEING ASKED TO BE WAIVED. | | | | | | 5. PARTIALLY SATISFIED. INDICATE THE LANDSCAPE BUFFER | | | LOCATIONS ON THE SITE PLAN AND LANDSCAPE PLAN. PROVIDE | | | A COMPLETE SITE PLAN FOR THE SITE. SHEET SP-1 DOES NOT | | | SHOW THE ENTIRE SITE. SHEET EPH-1 SHOWS BOTH SITES, SO | | | THE SITE PLAN SHOULD SHOW ALL OF THE RPD. | | | PROVIDE A COMPLETE LANDSCAPE PLAN FOR THE SITE MATCHING | | | THE SITE PLAN. SOUTHERN PORTION OF THE SITE NEEDS TO BE | | | SHOWN. | | | | | | 6. PARTIALLY SATISFIED. SHOW ALL CALCULATIONS FOR THE | | | REQUIRED TREES FOR BUFFER SEGMENTS ON A PERIMETER | | | BUFFER REQUIREMENT CHART INCLUDING LINEAR FOOTAGE OF | | | ALL PROPERTY LINE SEGMENTS. | | | BUFFER SEGMENT ADJACENT TO THE ROAD NEEDS TO BE LISTED | | | SEPARATELY, AS THIS HAS A REQUIRED 10 FOOT BUFFER. | | | BUFFER SEGMENTS NEED TO BE DIVIDED AND SHOWN AS VILLAGE | | | BLVD., WEST (ADJACENT TO CANAL), NORTH (ALL SEGMENTS), | | | AND EAST (ALONG I 95). SHOW TOTAL BUFFER LENGTH AND | | | DIVIDE BY 30, ROUND UP TO THE NEXT FULL TREE AND SHOW | | | THE REQUIRED NUMBER OF TREES, THE NUMBER PROVIDED, AND | | | THE NUMBER REQUESTED TO BE WAIVED FOR THAT SEGMENT. | | | | | | | | | 7. SATISFIED. PROVIDE CALCULATIONS FOR ALL BUFFERS | | | ALONG VILLAGE BOULEVARD WITH ACCESS DRIVEWAYS TO SHOW | | | THEY DO NOT EXCEED 25% INTERRUPTION FOR VEHICULAR | | | ACCESS AS REQUIRED BY SECTION 94-443(B)(2). | | | | | | 8. SATISFIED. SUBSTITUTION OF PALMS FOR TREES REQUIRES | | | 3:1 RATIO FOR SABAL PALMS AND MONTGOMERY PALMS. ADD UP | | | ALL TRUNKS AT 3:1 AND THEN DIVIDE BY 3 TO GET TREE | | | COUNT AND ADD ROYALS AND MEDJOOLS AS 1:1 PALMS. | | | RECALCULATE TREES COUNT PROVIDED. | | | | | | 9. SATISFIED. LIGUSTRUM DOES NOT QUALIFY AS A TREE | | | UNLESS PROVIDED AT 12 FOOT MINIMUM SIZE AND PLACED TO | | | BE ALLOWED TO GROW TO HEIGHT AND SPREAD MEETING THE | | | TREE DEFINITION. | | | | | | 10. SATISFIED. MODIFY THE PLANT LIST TO ADD COLUMNS FOR | | | NATIVE PLANT AND DROUGHT TOLERANCE LEVELS TO PROVIDE | | | EASIER REFERENCE. | | | | | | 11. PARTIALLY SATISFIED. ADD RELOCATED TREES TO THE | | | PLANT LIST AND COUNT THEM TOWARD THE REQUIRED TREES. | | | LIST SPECIES AND QUANTITIES OF EACH. | | | | | | 12. SATISFIED. SECTION 94-443(C)(3) REQUIRES THAT A | | | MINIMUM OF 75 PERCENT OF ALL TREES THAT ARE REQUIRED TO | | | BE PLANTED WITHIN THE INTERIOR OF AN OFF STREET PARKING | | | AREA SHALL BE CATEGORY 1 SHADE TREES. SHOW THE | | | PERCENTAGE OF CATEGORY 1 TREES PROVIDED FOR THE | | | REQUIRED LANDSCAPE AREAS. | | | | | | 13. PARTIALLY SATISFIED. PROVIDE AN EXHIBIT SHOWING THE | | | PARKING AREA SURFACE CALCULATIONS, PARKING SPACE AREAS | | | AND LANDSCAPE AREAS PROVIDED TO DEMONSTRATE COMPLIANCE | | | WITH SECTIONS 94-443 (C)(3) AND (4). | | | LIST THE CALCULATIONS ON THE DATA CHART. | | | PROVIDE AS A LARGER 1:20 SCALE PLAN FOR REVIEW OF THE | | | PROVIDED AREAS. | | | | | | | | | 14. SATISFIED. SHOW ALL REQUIRED CURBS ADJACENT TO | | | LANDSCAPE AREAS PER SECTION 94-443 (C)(5). THERE APPEAR | | | TO BE AREAS THAT ARE NOT CURBED. LANDSCAPE DIVIDER | | | STRIPS CAN HAVE CURBS INSTEAD OF WHEEL STOPS TO | | | INCREASE THE LANDSCAPE AREA FOR THE TREES. IF DRAINAGE | | | IS A CONCERN, THEY CAN BE DESIGNED TO ROUTE WATER INTO | | | THE LANDSCAPE AREAS. | | | | | | 15. SATISFIED. UPDATE THE FLORIDA FRIENDLY LANDSCAPE | | | CHART TO THE CURRENT CODE AND PROVIDE THE MINIMUM 50 | | | POINTS BASED ON THE PLANT LIST AND ITEMS THAT QUALIFY. | | | SOME WORDING AND PERCENTAGES ARE NOT CORRECT. | | | | | | 16. SATISFIED. PROVIDE LOCATIONS OF LIGHTING ON THE | | | LANDSCAPE PLAN TO AVOID CONFLICTS WITH LANDSCAPING. | | | | | | 17. PARTIALLY SATISFIED. THERE APPEAR TO BE CONFLICTS | | | IN SEVERAL LOCATIONS BETWEEN TREES AND WATER AND SEWER | | | LINES ON THE LANDSCAPE PLAN. ADJUST LOCATIONS OF TREES | | | OR UTILITY LINES TO RESOLVE CONFLICTS WITH LANDSCAPING. | | | FDC LOCATIONS NEED TO BE CHANGED TO AVOID TAKING SPACE | | | IN LANDSCAPE ISLANDS INTENDED FOR REQUIRED TREES. | | | . | | | 18. SATISFIED. PROVIDE LOCATIONS AND SCREENING FOR ALL | | | ABOVE GROUND UTILITY VALVES, BACKFLOW PREVENTERS, A/C | | | UNITS, AND FPL TRANSFORMERS. | | | | | | 19. PARTIALLY SATISFIED. SHOW LOCATIONS OF ANY ROOT | | | BARRIERS REQUIRED TO PROTECT UTILITY LINES AND PROVIDE | | | A ROOT BARRIER DETAIL. | | | SEE COMMENT #17 ABOVE. NON HERBICIDE HARD PLASTIC ROOT | | | BARRIER IS PREFERRED OVER BIO BARRIER. | | | | | | 20. PARTIALLY SATISFIED. SHOW COMPLIANCE WITH SECTION | | | 94-445 L. PLANT SPECIES. A MINIMUM OF 60 PERCENT OF | | | PLANT MATERIAL ADDED SHALL BE FLORIDA NATIVE OR DROUGHT | | | TOLERANT SPECIES SELECTED FROM THE CITY LIST OR THE | | | LIST OF SPECIES IN THE MOST RECENT EDITION OF SOUTH | | | FLORIDA WATER MANAGEMENT DISTRICT WATERWISE SOUTH | | | FLORIDA LANDSCAPES. | | | PERCENTAGE COULD NOT BE LOCATED ON SHEET LP-8. | | | | | | 21. PARTIALLY SATISFIED. THE LAKE AREA EXPANSION MUST | | | INCLUDE LITTORAL PLANTINGS PER SECTION 94-450. | | | TOTAL LINEAR FOOTAGE OF THE ENTIRE LAKE BANK MUST BE | | | PROVIDED, AND 50 PERCENT INDICATED, THEN WHAT IS BEING | | | PROVIDED. | | | ADDITIONAL COMMENTS 12/9/19: | | | | | | 22. THERE ARE EXISTING TREES AND PALMS WITHIN THE | | | PROPERTY OUTSIDE OF THE AREA SHOWN ON SHEET LD-1. | | | PROVIDE THE REQUIRED INFORMATION AND INCLUDE THEM ON | | | THE TREE DISPOSITION PLAN AND LIST. | | | | | | 23. CORRECT THE MITIGATION VALUES ON SHEET LP-1 FOR | | | ROYAL PALM AND SABAL PALM TO CATEGORY 3 AT 100 SQUARE | | | FEET MITIGATION CREDIT.FOR | | | | | | CONDITIONS OF APPROVAL | | | 1. PRIOR TO THE REMOVAL OR RELOCATION OF ANY TREES ON | | | THE PROPERTY, A TREE ALTERATION PERMIT SHALL BE | | | SUBMITTED, REVIEWED AND APPROVED BY THE DEVELOPMENT | | | SERVICES DEPARTMENT, PLANNING DIVISION. | | | |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
1 |
Status |
F |
Date |
10-09-2019 |
|
|
Cont ID |
|
| Sent By |
rcaranci |
Date |
10-09-2019 |
Time |
16:13 |
Rev Time |
0.00 |
| Received By |
rcaranci |
Date |
10-09-2019 |
Time |
16:13 |
Sent To |
|
|
| Notes |
| 2019-10-09 16:15:55 | FROM: RAY CARANCI, LANDSCAPE PLANNER 561-822-1462 | | | PROJECT: BROADSTONE LAKESIDE RPD | | | OCTOBER 9, 2019 | | | FUTURE LAND USE MAP AMENDMENT Z19090014: NO COMMENTS. | | | REZONING TO RPD Z19090015 | | | I HAVE REVIEWED THE ABOVE REFERENCED PETITION, AND | | | PROVIDE THE FOLLOWING COMMENTS: | | | | | | 1. PROVIDE THE FOLLOWING CORRECTIONS TO THE TREE | | | DISPOSITION PLAN SHEET LD-1: | | | ? BISCHOFIA IS ON THE PROHIBITED TREE LIST AND THE FOUR | | | LISTED DO NOT REQUIRE MITIGATION. | | | ? CANOPY SQUARE FOOTAGE FOR MITIGATION DUE FOR ANY | | | TREES PROPOSED FOR REMOVAL MUST BE IN A SEPARATE | | | COLUMN, AND THE TOTAL PROVIDED FOR THE COLUMN. SQUARE | | | FOOTAGE FOR RELOCATED TREES IS NOT REQUIRED AND MUST BE | | | IN A SEPARATE COLUMN IF INCLUDED ON THE LIST. | | | ? REMOVALS OF PALMS MUST INCLUDE THE MITIGATION | | | REQUIRED BY CATEGORY. ADONIDIA, FOXTAIL, QUEEN PALM AND | | | WASHINGTONIA PALM ARE ALL CATEGORY 4 REQUIRING | | | MITIGATION OF 50 SQ FT EACH. | | | ? INCLUDE A CHART FOR TREE MITIGATION PROVIDED BASED ON | | | THE PLANT LIST AND PROVIDE THE TOTAL FOR THE SQUARE | | | FOOTAGE. | | | | | | 2. SECTION 94-448 (D)(3) REQUIRES NATIVE TREES IN GOOD | | | CONDITION TO BE PRESERVED ON SITE OR RELOCATED. A | | | SIGNIFICANT NUMBER OF LIVE OAK TREES (26) MANY OF LARGE | | | CANOPY SIZE ARE LISTED TO BE REMOVED, AND THE CONDITION | | | LISTED AS FAIR. PROVIDE THE METHOD OF DETERMINATION OF | | | THE CONDITION ASSESSMENT, AND THE SOURCE OF THE | | | DETERMINATION. STAFF IS VERY FAMILIAR WITH THE TREES ON | | | SITE AND WILL MEET ON SITE WITH THE LANDSCAPE ARCHITECT | | | AND TREE RELOCATION CONTRACTOR TO ASSESS THE CONDITION | | | OF THE TREES LISTED AS FAIR. | | | | | | 3. SHOW THE CALCULATIONS FOR MINIMUM SHADE TREE AND | | | FLOWERING TREE REQUIREMENTS PER SECTION 94-443(C)(2)B. | | | BASED ON OPEN SPACE AND ADD REQUIRED TREES PER UNIT | | | (280) TO ESTABLISH THE MINIMUM TREES REQUIRED FOR THE | | | SITE. OPEN SPACE REQUIRED FOR RESIDENTIAL ZONING | | | INCLUDES SETBACKS, PARKING, SIDEWALKS, LANDSCAPE | | | ISLANDS AND BUILDING PERIMETER PLANTINGS. A SEPARATE | | | OPEN SPACE PLAN MAY BE SUBMITTED SHOWING THE OPEN SPACE | | | AREAS COUNTED. | | | | | | | | | 4. SHOW THE REQUIRED 10 FOOT LANDSCAPE BUFFER ADJACENT | | | TO THE RIGHT OF WAY AND THE 5 FOOT LANDSCAPE BUFFER | | | PLANTINGS ALONG ALL OTHER PROPERTY LINES WITH THE | | | REQUIRED TREES OR NUMBER OF SUBSTITUTE PALMS PER | | | CURRENT CODE REQUIREMENTS OF SECTION 94-443(D). IF THE | | | BUFFER CANNOT BE PROVIDED ALONG THE PROPERTY LINE, A | | | WAIVER MUST BE REQUESTED, AND ALTERNATIVES PRESENTED TO | | | PROVIDE COMPARABLE BUFFERING ON THE SITE. | | | | | | 5. INDICATE THE LANDSCAPE BUFFER LOCATIONS ON THE SITE | | | PLAN AND LANDSCAPE PLAN. | | | | | | 6. SHOW ALL CALCULATIONS FOR THE REQUIRED TREES FOR | | | BUFFER SEGMENTS ON A PERIMETER BUFFER REQUIREMENT CHART | | | INCLUDING LINEAR FOOTAGE OF ALL PROPERTY LINE SEGMENTS. | | | BUFFER SEGMENT ADJACENT TO THE ROAD NEEDS TO BE LISTED | | | SEPARATELY, AS THIS HAS A REQUIRED 10 FOOT BUFFER. | | | | | | 7. PROVIDE CALCULATIONS FOR ALL BUFFERS ALONG VILLAGE | | | BOULEVARD WITH ACCESS DRIVEWAYS TO SHOW THEY DO NOT | | | EXCEED 25% INTERRUPTION FOR VEHICULAR ACCESS AS | | | REQUIRED BY SECTION 94-443(B)(2). | | | | | | 8. SUBSTITUTION OF PALMS FOR TREES REQUIRES 3:1 RATIO | | | FOR SABAL PALMS AND MONTGOMERY PALMS. ADD UP ALL TRUNKS | | | AT 3:1 AND THEN DIVIDE BY 3 TO GET TREE COUNT AND ADD | | | ROYALS AND MEDJOOLS AS 1:1 PALMS. RECALCULATE TREES | | | COUNT PROVIDED. | | | | | | 9. LIGUSTRUM DOES NOT QUALIFY AS A TREE UNLESS PROVIDED | | | AT 12 FOOT MINIMUM SIZE AND PLACED TO BE ALLOWED TO | | | GROW TO HEIGHT AND SPREAD MEETING THE TREE DEFINITION. | | | | | | 10. MODIFY THE PLANT LIST TO ADD COLUMNS FOR NATIVE | | | PLANT AND DROUGHT TOLERANCE LEVELS TO PROVIDE EASIER | | | REFERENCE. | | | | | | 11. ADD RELOCATED TREES TO THE PLANT LIST AND COUNT | | | THEM TOWARD THE REQUIRED TREES. | | | | | | 12. SECTION 94-443(C)(3) REQUIRES THAT A MINIMUM OF 75 | | | PERCENT OF ALL TREES THAT ARE REQUIRED TO BE PLANTED | | | WITHIN THE INTERIOR OF AN OFF STREET PARKING AREA SHALL | | | BE CATEGORY 1 SHADE TREES. SHOW THE PERCENTAGE OF | | | CATEGORY 1 TREES PROVIDED FOR THE REQUIRED LANDSCAPE | | | AREAS. | | | | | | 13. PROVIDE AN EXHIBIT SHOWING THE PARKING AREA SURFACE | | | CALCULATIONS, PARKING SPACE AREAS AND LANDSCAPE AREAS | | | PROVIDED TO DEMONSTRATE COMPLIANCE WITH SECTIONS 94-443 | | | (C)(3) AND (4). | | | LIST THE CALCULATIONS ON THE DATA CHART. | | | | | | 14. SHOW ALL REQUIRED CURBS ADJACENT TO LANDSCAPE AREAS | | | PER SECTION 94-443 (C)(5). THERE APPEAR TO BE AREAS | | | THAT ARE NOT CURBED. LANDSCAPE DIVIDER STRIPS CAN HAVE | | | CURBS INSTEAD OF WHEEL STOPS TO INCREASE THE LANDSCAPE | | | AREA FOR THE TREES. IF DRAINAGE IS A CONCERN, THEY CAN | | | BE DESIGNED TO ROUTE WATER INTO THE LANDSCAPE AREAS. | | | | | | 15. UPDATE THE FLORIDA FRIENDLY LANDSCAPE CHART TO THE | | | CURRENT CODE AND PROVIDE THE MINIMUM 50 POINTS BASED ON | | | THE PLANT LIST AND ITEMS THAT QUALIFY. SOME WORDING AND | | | PERCENTAGES ARE NOT CORRECT. | | | | | | 16. PROVIDE LOCATIONS OF LIGHTING ON THE LANDSCAPE PLAN | | | TO AVOID CONFLICTS WITH LANDSCAPING. | | | | | | 17. THERE APPEAR TO BE CONFLICTS IN SEVERAL LOCATIONS | | | BETWEEN TREES AND WATER AND SEWER LINES ON THE | | | LANDSCAPE PLAN. ADJUST LOCATIONS OF TREES OR UTILITY | | | LINES TO RESOLVE CONFLICTS WITH LANDSCAPING. | | | . | | | 18. PROVIDE LOCATIONS AND SCREENING FOR ALL ABOVE | | | GROUND UTILITY VALVES, BACKFLOW PREVENTERS, A/C UNITS, | | | AND FPL TRANSFORMERS. | | | | | | 19. SHOW LOCATIONS OF ANY ROOT BARRIERS REQUIRED TO | | | PROTECT UTILITY LINES AND PROVIDE A ROOT BARRIER | | | DETAIL. | | | | | | 20. SHOW COMPLIANCE WITH SECTION 94-445 L. PLANT | | | SPECIES. A MINIMUM OF 60 PERCENT OF PLANT MATERIAL | | | ADDED SHALL BE FLORIDA NATIVE OR DROUGHT TOLERANT | | | SPECIES SELECTED FROM THE CITY LIST OR THE LIST OF | | | SPECIES IN THE MOST RECENT EDITION OF SOUTH FLORIDA | | | WATER MANAGEMENT DISTRICT WATERWISE SOUTH FLORIDA | | | LANDSCAPES. | | | | | | 21. THE LAKE AREA EXPANSION MUST INCLUDE LITTORAL | | | PLANTINGS PER SECTION 94-450. | | | | | | CONDITIONS OF APPROVAL | | | 1. PRIOR TO THE REMOVAL OR RELOCATION OF ANY TREES ON | | | THE PROPERTY, A TREE ALTERATION PERMIT SHALL BE | | | SUBMITTED, REVIEWED AND APPROVED BY THE DEVELOPMENT | | | SERVICES DEPARTMENT, PLANNING DIVISION. | | | |
|
|
| Review Stop |
PARK |
PARKING |
| Rev No |
1 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
|
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
POLICE |
POLICE |
| Rev No |
1 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
|
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
PW |
PUBLIC WORKS |
| Rev No |
3 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
PW |
PUBLIC WORKS |
| Rev No |
2 |
Status |
F |
Date |
12-05-2019 |
|
|
Cont ID |
|
| Sent By |
|
Date |
12-05-2019 |
Time |
|
Rev Time |
0.00 |
| Received By |
|
Date |
12-05-2019 |
Time |
|
Sent To |
|
|
| Notes |
| 2019-12-05 07:40:19 | REGARDING THE DUMPSTER ENCLOSURE: | | | PLEASE PROVIDE A DETAILED DRAWING OF THE DUMPSTER | | | ENCLOSURE INDICATING ITS COMPLIANCE TO THE LATEST | | | REVISION RELEASED, JUNE 2019. | | | | | | REGARDING THE BULK ENCLOSURE: | | | ALSO, PLEASE PROVIDE DETAILED DRAWING ON THE BULK | | | ENCLOSURE. PEASE NOTE EACH ENCLOSURE DOOR SHALL BE | | | EQUIPPED WITH A PIN TO HELP SECURE THE DOOR WHEN | | | OPENED. A MIN. 3-IN DEEP PIN HOLE NEEDED IN THE ASPHALT | | | FOR EACH DOOR TO HELP SECURE THE DOORS WHEN FULLY OPEN | | | AT A 90+ DEG. ANGLE. | | | | | | MATT HEJAZI | | | DEPT. OF PUBLIC WORKS | | | [email protected] | | | 561-822-2045 | | | |
|
|
| Review Stop |
PW |
PUBLIC WORKS |
| Rev No |
1 |
Status |
F |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
10-08-2019 |
Time |
|
Rev Time |
|
| Received By |
|
Date |
10-08-2019 |
Time |
|
Sent To |
|
|
| Notes |
| 2019-10-08 15:06:28 | | | | - FOR A FREESTANDING SITE DUMPSTER ENCLOSURE, THE | | | ENCLOSURE SHALL COMPLY WITH THE LATEST REVISION OF CITY | | | OF WEST PALM BEACH GENERAL CONSTRUCTION-GARBAGE | | | ENCLOSURE STANDARD, CG-8. | | | - PLEASE PROVIDE A DESIGNATED LOCATION FOR THE BULK | | | ITEM PICK UP | | | | | | | | | MATT HEJAZI | | | DEPT. OF PUBLIC WORKS | | | [email protected] | | | 561-822-2045 | | | |
|
|
| Review Stop |
STORM |
STORMWATER |
| Rev No |
2 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
STORM |
STORMWATER |
| Rev No |
1 |
Status |
F |
Date |
10-08-2019 |
|
|
Cont ID |
|
| Sent By |
tward |
Date |
10-08-2019 |
Time |
16:51 |
Rev Time |
|
| Received By |
tward |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2019-10-08 16:52:40 | THIS IS A CONCEPTUAL LEVEL REVIEW. CONSTRUCTION LEVEL | | | DETAILS, DESIGN CALCULATIONS AND THE POLLUTION | | | PREVENTION PLAN WILL BE REVIEWED AS PART OF THE | | | ENGINEERING DEVELOPMENT APPROVAL AND BUILDING PERMIT | | | APPLICATION PROCESSES. THE ENGINEERING DEVELOPMENT | | | APPROVAL APPLICATION FORMS CAN BE DOWNLOADED AT | | | HTTP://WPB.ORG/DEPARTMENTS/ENGINEERING-PUBLIC-WORKS/FOR | | | MS,-PERMITS-APPLICATIONS | | | | | | THE FOLLOWING COMMENTS MUST BE ADDRESSED PRIOR TO SITE | | | PLAN APPROVAL: | | | 1. MIN. FFE IS TWO FEET ABOVE BASE FLOOD ELEVATION FOR | | | STRUCTURES WITHIN SPECIAL FLOOD HAZARD AREAS. | | | | | | 2. SHOW THE CHURCH'S STORMWATER OUTFALL PIPE (AND | | | EASEMENT?) ON THE PLANS. | | | | | | 3. SHOW AND LABEL PERIMETER BERM ALONG THE PROPERTY | | | LINES. PROVIDE A DETAIL OF THE BERM. | | | | | | 4. ADD SPOT GRADES AROUND THE BUILDINGS AND FOR THE | | | SIDEWALKS BETWEEN THE BUILDINGS. | | | | | | 5. CONSIDER REDUCING THE LENGTH OF THE PARKING SPACES, | | | PROVIDE TWO FEET OF OVERHANG AND REPLACING THE WHEEL | | | STOPS WITH CURBS. | | | | | | 6. ON SECTION A-A (SHEET C-127), PROVIDE A 6 INCH DEEP | | | SWALE ALONG THE BACK OF SIDEWALK WITH SLOPES 4:1 OR | | | FLATTER. | | | | | | 7. FLOATING TURBIDITY BARRIER WILL BE NEEDED IN THE | | | LAKE TO CONTROL TURBIDITY DURING LAKE EXCAVATION. | | | | | | 8. IDENTIFY WHERE THE EXISTING POND/WETLAND WILL BE | | | RELOCATED TO WHEN THE LAKE IS EXPANDED. | | | | | | 9. IDENTIFY WHO WILL BE RESPONSIBLE FOR THE 20' LAKE | | | MAINTENANCE EASEMENT. | | | | | | 10. ON SHEET C-121, THE GRADING PLAN SHOWS SPOT GRADES | | | OF 14.65 ON THE DRIVEWAY AND FLOW ARROWS POINTING | | | TOWARD ELEVATION 15.00. | | | | | | 11. NUMBER THE DRAINAGE STRUCTURES FOR EASE OF | | | REFERENCE. IDENTIFY THE CONTROL STRUCTURE. | | | | | | 12. POLLUTANT RETARDANT BAFFLES (PRB'S) WILL BE NEEDED | | | FOR ALL STRUCTURES CONNECTED TO EXFILTRATION TRENCHES. | | | | | | 12. IT APPEARS THERE ARE CLEANOUTS AT ALL OF THE | | | SANITARY SEWER LATERAL WYE CONNECTIONS TO THE SEWER | | | MAIN. | | | | | | 13. SHOW MILL AND RESURFACE LIMITS ON VILLAGE BLVD FOR | | | THE UTILITY TRENCH CUTS. | | | | | | | | | THE FOLLOWING COMMENTS MUST BE ADDRESSED PRIOR TO | | | ISSUANCE OF CONSTRUCTION AUTHORIZATION INCLUDING | | | BUILDING PERMITS AND ENGINEERING DEVELOPMENT APPROVAL. | | | | | | 1. AN ENGINEERING DEVELOPMENT APPROVAL APPLICATION MAY | | | BE REQUIRED FROM THE ENGINEERING SERVICES DEPARTMENT. | | | THE ENGINEERING DEVELOPMENT APPROVAL APPLICATION FORMS | | | CAN BE DOWNLOADED AT: HTTP://WPB.ORG/DEPARTMENTS/ENGINE | | | ERING-PUBLIC-WORKS/FORMS,-PERMITS-APPLICATIONS | | | | | | 2. EROSION CONTROL PLAN AND DETAILS TO BE SUBMITTED | | | WITH THE ENGINEERING PERMIT APPLICATION. | | | | | | 3. PROVIDE A COPY OF THE SFWMD ERP PRIOR TO STARTING | | | CONSTRUCTION. | | | | | | TRACY WARD, PE | | | SENIOR STORMWATER ENGINEER | | | ENGINEERING SERVICES DEPARTMENT | | | 561-494-1120 | | | [email protected] | | | |
|
|
| Review Stop |
SURVEY |
SURVEYING |
| Rev No |
2 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SURVEY |
SURVEYING |
| Rev No |
1 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
|
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
TRAFFIC |
TRAFFIC ENGINEERING |
| Rev No |
4 |
Status |
F |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
02-26-2020 |
Time |
|
Rev Time |
0.00 |
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2020-02-26 13:39:05 | TRAFFIC ANALYSIS COMMENTS: | | | 1. PROVIDE COUNTY TPS LETTER. | | | | | | SITE PLAN COMMENTS: | | | 2. PLANNED DEVELOPMENT (PD) IS REQUIRED TO BE | | | CONSISTENT WITH ALL ELEMENTS OF THE CITY'S | | | COMPREHENSIVE PLAN. PER THE CITY'S COMPREHENSIVE PLAN | | | TRANSPORTATION ELEMENT, CONSTRUCT A 12-FOOT SIDEWALK ON | | | VILLAGE BOULEVARD ALONG SITE FRONTAGE. THE COST | | | ESTIMATE FOR THE PROPOSED IN-LIEU PAYMENT DOES NOT | | | APPEAR TO INCLUDE DEMOLITION, MOT, MOBILIZATION, | | | STABILIZATION AND UTILITY ADJUSTMENT WHICH MAY BE | | | ESSENTIAL TO THE SIDEWALK IMPROVEMENT. | | | 3. THE CITY DOES NOT SUPPORT THE EXCLUSIVE RIGHT-TURN | | | LANE AT THE SITE DRIVEWAY BECAUSE THIS WOULD FURTHER | | | ENCOURAGE HIGHER VEHICULAR SPEED ON VILLAGE BOULEVARD. | | | 4. THE PROPOSED DEVELOPMENT IS EXPECTED TO INCREASE | | | TRAFFIC AT THE SITE DRIVEWAYS BY MORE THAN 20 TIMES | | | WHICH WILL INCREASE CONFLICT WITH EXISTING TRAFFIC ON | | | VILLAGE BOULEVARD. PLEASE PROPOSE MITIGATIONS SUCH AS | | | ROUNDABOUTS AND MEDIAN CLOSURE TO MITIGATE FOR THE | | | INCREASED CONFLICT AND PROVIDE SAFER PEDESTRIAN ACCESS | | | TO THE PROPERTY. | | | | | | SHING TSOI | | | CITY IN-HOUSE TRAFFIC CONSULTANT | | | 561-494-1141 | | | [email protected] | | | (IN-HOUSE ON TUESDAYS AND WEDNESDAYS) |
|
|
| Review Stop |
TRAFFIC |
TRAFFIC ENGINEERING |
| Rev No |
3 |
Status |
F |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
01-17-2020 |
Time |
|
Rev Time |
0.00 |
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2020-01-17 17:02:01 | TRAFFIC ANALYSIS COMMENTS: | | | 1. PROVIDE COUNTY TPS LETTER. | | | | | | | | | SITE PLAN COMMENTS: | | | 2. INCLUDE IN THE CIVIL PLAN THE DIAGONAL HATCHING ON | | | THE PORTION OF INBOUND LANE NOT NEEDED BY PASSENGER | | | CARS AT THE SOUTHERN ENTRANCE. | | | 3. OPEN UP THE 8-FOOT WATERFRONT WALKWAY AND OVERLOOK | | | AREAS FOR PUBLIC USE. | | | 4. PLANNED DEVELOPMENT (PD) IS REQUIRED TO BE | | | CONSISTENT WITH ALL ELEMENTS OF THE CITY?S | | | COMPREHENSIVE PLAN. PER THE CITY?S COMPREHENSIVE PLAN | | | TRANSPORTATION ELEMENT, CONSTRUCT A 12-FOOT SIDEWALK ON | | | VILLAGE BOULEVARD ALONG SITE FRONTAGE. | | | | | | | | | CONDITIONS: | | | 1. THE FLU AMENDMENT WILL BE VOLUNTARILY RESTRICTED TO | | | A MAXIMUM OF 30.5 DWELLING UNIT PER ACRE PER THE FLU | | | AMENDMENT TRAFFIC ANALYSIS OR AS REVISED BASED ON THE | | | REVISED FLU AMENDMENT TRAFFIC ANALYSIS. | | | 2. AS A MITIGATION TO DECREASED SAFETY ASSOCIATED WITH | | | INCREASED TRAFFIC AND CONSISTENT WITH THE CITY?S | | | COMPREHENSIVE PLAN, PROVIDE TRAFFIC CALMING MEASURES ON | | | VILLAGE BOULEVARD TO REDUCE VEHICULAR TRAVEL SPEED AND | | | IMPROVE SAFETY ON VILLAGE BOULEVARD. | | | 3. AS A MITIGATION TO INCREASED TRAFFIC AND CONSISTENT | | | WITH THE CITY?S COMPREHENSIVE PLAN, IMPLEMENT | | | TRANSPORTATION DEMAND MANAGEMENT PROGRAMS INCLUDING | | | PROVIDING COMMUNITY SHUTTLE SERVICE. | | | | | | | | | SHING TSOI | | | CITY IN-HOUSE TRAFFIC CONSULTANT | | | 561-494-1141 | | | [email protected] | | | (IN-HOUSE ON TUESDAYS AND WEDNESDAYS) |
|
|
| Review Stop |
TRAFFIC |
TRAFFIC ENGINEERING |
| Rev No |
2 |
Status |
F |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
11-27-2019 |
Time |
|
Rev Time |
0.00 |
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2019-11-27 17:08:46 | FLU AMENDMENT TRAFFIC ANALYSIS COMMENTS: | | | 1. IN TABLE 6, SOME OF THE YEAR 2019 TRAFFIC VOLUMES DO | | | NOT APPEAR TO BE CONSISTENT WITH THE VOLUMES INCLUDED | | | IN THE APPENDIX, E.G. VOLUMES ON VILLAGE BOULEVARD | | | BETWEEN CUMBERLAND DRIVE AND SHILOH DRIVE. PLEASE | | | VERIFY AND REVISE. | | | 2. CONSISTENT WITH THE FLU AMENDMENT TRAFFIC ANALYSIS, | | | THE PROPOSED FLU AMENDMENT SHALL BE LIMITED IN | | | INTENSITIES WHICH WOULD NOT CAUSE SIGNIFICANT IMPACT ON | | | 45TH STREET UNLESS THE IMPROVEMENT TO WIDEN 45TH STREET | | | BETWEEN VILLAGE BOULEVARD AND I-95 FROM 6 LANES TO 8 | | | LANES IS IN PLACE OR IS INCLUDED IN THE PALM BEACH | | | TPA?S LRTP COST-FEASIBLE PLAN, 5-YEAR TRANSPORTATION | | | IMPROVEMENT PLAN OR FDOT?S 5-YEAR WORK PROGRAM. | | | TRAFFIC ANALYSIS COMMENTS: | | | 3. PROVIDE COUNTY TPS LETTER. | | | 4. IN TABLE 3A, SOME OF THE YEAR 2019 TRAFFIC VOLUMES | | | DO NOT APPEAR TO BE CONSISTENT WITH THE VOLUMES | | | INCLUDED IN THE APPENDIX, E.G. VOLUMES ON VILLAGE | | | BOULEVARD BETWEEN CUMBERLAND DRIVE AND SHILOH DRIVE. | | | PLEASE VERIFY AND REVISE. | | | 5. PLEASE USE HCM 6TH METHODOLOGY INSTEAD OF HCM 2000 | | | METHODOLOGY IN THE SYNCHRO ANALYSIS. | | | 6. PLEASE VERIFY THE CONFIGURATIONS AT SOME | | | INTERSECTIONS, E.G. VILLAGE BOULEVARD/COMMUNITY DRIVE | | | IS MISSING A RIGHT-TURN OVERLAP IN THE SYNCHRO | | | ANALYSIS, THE COORDINATION MODE (FREE OR COORDINATED) | | | AND CYCLE LENGTHS (IF COORDINATED) AT VILLAGE | | | BOULEVARD/SHILOH DRIVE AND VILLAGE BOULEVARD/COMMUNITY | | | DRIVE. PLEASE ATTACH SIGNAL TIMING SHEETS. | | | 7. PER CITY CODE SECTION 94-32(A), A PLANNED | | | DEVELOPMENT (PD) IS REQUIRED TO BE CONSISTENT WITH ALL | | | ELEMENTS OF THE CITY?S COMPREHENSIVE PLAN. THE CITY?S | | | COMPREHENSIVE PLAN TRANSPORTATION ELEMENT POLICY | | | 2.1.1(A) ADOPTS A VEHICULAR LOS E STANDARD ON CITY | | | STREETS. WHILE THE COST OF MITIGATING TRANSPORTATION | | | DEFICIENT WITHOUT THE PROJECT TRAFFIC UNDER REVIEW IS | | | NOT OBLIGED BY THE DEVELOPMENT PER FLORIDA STATUTES | | | 163.3180, THE F.S. DOES NOT EXEMPT THE DEVELOPMENT FROM | | | MITIGATING THE TRANSPORTATION IMPACT GENERATED FROM THE | | | DEVELOPMENT, NOR DOES IT EXEMPT THE DEVELOPMENT FROM | | | MEETING THE REQUIREMENTS OF CITY?S CODE OF ORDINANCE. | | | PLEASE PROPOSE MITIGATION MEASURES, OR THE PROPOSED | | | DEVELOPMENT SHALL BE LIMITED IN INTENSITIES WHICH WOULD | | | NOT CAUSE SIGNIFICANT IMPACT ON 45TH STREET UNLESS THE | | | IMPROVEMENT TO WIDEN 45TH STREET BETWEEN VILLAGE | | | BOULEVARD AND I-95 FROM 6 LANES TO 8 LANES IS IN PLACE | | | OR IS INCLUDED IN THE PALM BEACH TPA?S 5-YEAR | | | TRANSPORTATION IMPROVEMENT PLAN OR FDOT?S 5-YEAR WORK | | | PROGRAM. | | | 8. PLEASE CONSIDER MITIGATION MEASURES SUCH AS | | | ENCOURAGING PEDESTRIAN AND BICYCLE MODES ON VILLAGE | | | BOULEVARD BY PROVIDING MULTI-USE TRAILS, REDUCING | | | VEHICULAR TRAVEL SPEED AND IMPROVING SAFETY ON VILLAGE | | | BOULEVARD, AND IMPLEMENTATION OF TRANSPORTATION DEMAND | | | MANAGEMENT PROGRAMS, E.G. COMMUNITY SHUTTLE SERVICE. | | | 9. ADDITIONAL COMMENTS MAY BE PROVIDED WHEN THE TRAFFIC | | | ANALYSIS IS REVISED. | | | SITE PLAN COMMENTS: | | | 10. PROVIDE DIAGONAL HATCHING ON THE PORTION OF INBOUND | | | LANE NOT NEEDED BY PASSENGER CARS AT THE SOUTHERN | | | ENTRANCE. | | | 11. PROVIDE TURNAROUND SPACE FOR THE DEAD-END PARKING | | | AT THE NORTHEAST CORNER OF THE SITE. | | | 12. PLANNED DEVELOPMENT (PD) IS INTENDED FOR | | | DEVELOPMENTS WITH INNOVATIVE DESIGNS AND IS REQUIRED TO | | | BE CONSISTENT WITH ALL ELEMENTS OF CITY?S COMPREHENSIVE | | | PLAN. PLEASE IDENTIFY INNOVATIVE DESIGN ELEMENTS | | | ASSOCIATED WITH THIS RPD. | | | 13. CLARIFY IF THE 8-FOOT WATERFRONT WALKWAY AND | | | OVERLOOK AREAS ARE OPEN FOR PUBLIC USE. | | | 14. CONSTRUCT 12-FOOT SIDEWALK WITH 6-FOOT LANDSCAPE | | | BUFFER AND SHADE TREES ON VILLAGE BOULEVARD ALONG SITE | | | FRONTAGE. IT APPEARS THE EXISTING AND PROPOSED | | | RELOCATED SHADE TREES ARE SET BACK APPROXIMATELY 22 | | | FEET FROM THE CURB. ALSO, CONSIDER CONSTRUCTING THE | | | SIDEWALK AROUND THE SHADE TREES AND UTILITIES AS IT | | | APPEARS THERE ARE 24 FEET OF SPACE BETWEEN THE PARKING | | | SPACES AND SHADE TREES. | | | CONDITIONS: | | | 1. THE FLU AMENDMENT WILL BE VOLUNTARILY RESTRICTED TO | | | A MAXIMUM OF 30.5 DWELLING UNIT PER ACRE PER THE FLU | | | AMENDMENT TRAFFIC ANALYSIS OR AS REVISED BASED ON THE | | | REVISED FLU AMENDMENT TRAFFIC ANALYSIS. | | | | | | | | | SHING TSOI | | | CITY IN-HOUSE TRAFFIC CONSULTANT | | | 561-494-1141 | | | [email protected] | | | (IN-HOUSE ON TUESDAYS AND WEDNESDAYS) |
|
|
| Review Stop |
TRAFFIC |
TRAFFIC ENGINEERING |
| Rev No |
1 |
Status |
F |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
10-08-2019 |
Time |
|
Rev Time |
|
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2019-10-08 16:46:45 | FLU AMENDMENT TRAFFIC ANALYSIS COMMENTS: | | | 1. INCLUDE THE SOURCES OF THE TRAFFIC DATA USED IN | | | TABLES 5 AND 6. ALSO, THE EXISTING TRAFFIC VOLUMES FOR | | | VILLAGE BOULEVARD BETWEEN SHILOH DRIVE AND 45TH STREET | | | ARE SHOWN AS 0. PLEASE REVISE. | | | 2. THE GENERALIZED SERVICE VOLUMES FOR VILLAGE | | | BOULEVARD SHOWN IN TABLE 8 ARE NOT CONSISTENT WITH THE | | | VOLUMES PUBLISHED IN PALM BEACH COUNTY?S TPS. PLEASE | | | VERIFY AND REVISE. ALSO, PLEASE USE THE LATEST ADOPTED | | | 2040 COST FEASIBLE MODEL VOLUMES FROM PALM BEACH TPA | | | DATED 8/17/2016. | | | 3. ADDITIONAL COMMENTS MAY BE PROVIDED WHEN THE TRAFFIC | | | ANALYSIS IS REVISED. | | | 4. ADDITIONAL COMMENTS MAY BE PROVIDED BY OTHER | | | REVIEWING AGENCIES AS PART OF THE EXPEDITED STATE | | | REVIEW PROCESS PER FLORIDA STATUTES 163.3184. | | | TRAFFIC ANALYSIS COMMENTS: | | | 5. PROVIDE COUNTY TPS LETTER. | | | 6. PLEASE INCLUDE HCM 6TH ANALYSIS AT THE FOLLOWING | | | INTERSECTIONS: | | | A. VILLAGE BOULEVARD/45TH STREET | | | B. VILLAGE BOULEVARD/SHILOH DRIVE | | | C. VILLAGE BOULEVARD/NORTH SITE DRIVEWAY | | | D. VILLAGE BOULEVARD/SOUTH SITE DRIVEWAY | | | E. VILLAGE BOULEVARD/CUMBERLAND DRIVE | | | F. VILLAGE BOULEVARD/SHENANDOAH ROAD | | | G. VILLAGE BOULEVARD/COMMUNITY DRIVE | | | 7. THE EXISTING TRAFFIC VOLUMES FOR VILLAGE BOULEVARD | | | BETWEEN SHILOH DRIVE AND 45TH STREET ARE SHOWN AS 0 IN | | | TABLE 3. ALSO, INCLUDE THE SOURCES OF TRAFFIC DATA. THE | | | LINK VOLUMES SHOULD BE BASED ON THE LATEST LINK OR | | | INTERSECTION COUNTS WHEN APPLICABLE. PLEASE REVISE. | | | 8. ATTACH THE COMMITTED TRIP INFORMATION FOR 45TH | | | STREET/VILLAGE BOULEVARD, VILLAGE BOULEVARD/COMMUNITY | | | DRIVE, AND ADDITIONAL STUDY INTERSECTIONS AS REQUIRED | | | BELOW. THE COMMITTED TRIPS SHOWN FOR 45TH | | | STREET/VILLAGE BOULEVARD APPEAR TO BE BASED ON THE | | | COMMITTED TRIPS AT PALM BEACH LAKES BOULEVARD/SPENCER | | | DRIVE ATTACHED IN THE REPORT. PLEASE VERIFY AND REVISE. | | | 9. THE RTOR REDUCTION ON SHARED THROUGH-RIGHT LANES | | | SHOULD BE LESS THAN 60 VPH. PLEASE VERIFY AND REVISE. | | | 10. PAGE 13 OF THE REPORT REFERENCES TABLE 5 BUT TABLE | | | 5 IS NOT INCLUDED. PLEASE VERIFY AND REVISE. | | | 11. CONSISTENT WITH THE TRAFFIC ANALYSIS, THE PROPOSED | | | DEVELOPMENT SHALL BE LIMITED IN INTENSITIES WHICH WOULD | | | NOT CAUSE SIGNIFICANT IMPACT ON 45TH STREET UNLESS THE | | | IMPROVEMENT TO WIDEN 45TH STREET BETWEEN VILLAGE | | | BOULEVARD AND I-95 FROM 6 LANES TO 8 LANES IS IN PLACE | | | OR IS INCLUDED IN THE PALM BEACH TPA?S 5-YEAR | | | TRANSPORTATION IMPROVEMENT PLAN OR FDOT?S 5-YEAR WORK | | | PROGRAM. | | | 12. ADDITIONAL COMMENTS MAY BE PROVIDED WHEN THE | | | TRAFFIC ANALYSIS IS REVISED. | | | SITE PLAN COMMENTS: | | | 13. PROVIDE PEDESTRIAN ACCESS FROM THE NORTH ENTRANCE | | | ON VILLAGE BOULEVARD. | | | 14. PROVIDE CROSS VEHICULAR ACCESS BETWEEN THE CHURCH | | | AND THE RESIDENTIAL DEVELOPMENT ALONG THE EAST SIDE OF | | | THE CHURCH SITE, AND CROSS PEDESTRIAN ACCESSES ALONG | | | THE EAST AND NORTH SIDES OF THE CHURCH SITE. | | | 15. PROVIDE TURNAROUND SPACE FOR THE DEAD-END PARKING | | | NEAR THE DOG PARK. | | | 16. CLARIFY THE RIGHT-OF-WAY OF THE 3-LEGGED AND | | | 5-LEGGED INTERNAL INTERSECTIONS. PROVIDE STOP BARS AND | | | STOP SIGNS FOR A COMPLETE REVIEW. CONSIDER REALIGNING | | | THE INTERNAL INTERSECTIONS TO INTERSECTION AT 90-DEGREE | | | ANGLE. | | | 17. INCLUDE THE REQUIRED BICYCLE PARKING IN THE SITE | | | DATA TABLE AND SITE PLAN. | | | 18. PLANNED DEVELOPMENT (PD) IS INTENDED FOR | | | DEVELOPMENTS WITH INNOVATIVE DESIGNS AND IS REQUIRED TO | | | BE CONSISTENT WITH ALL ELEMENTS OF CITY?S COMPREHENSIVE | | | PLAN. PLEASE IDENTIFY INNOVATIVE DESIGN ELEMENTS | | | ASSOCIATED WITH THIS RPD. | | | 19. CONSTRUCT 12-FOOT SIDEWALK WITH 6-FOOT LANDSCAPE | | | BUFFER AND SHADE TREES ON VILLAGE BOULEVARD ALONG SITE | | | FRONTAGE. | | | 20. SIDEWALK SHOULD MAINTAIN THE SAME LEVEL AS THE | | | DRIVEWAYS. | | | 21. PROVIDE A 12-FOOT RECREATIONAL TRAIL ALONG THE | | | WATER FRONT WITH PICNIC AREAS LOCATED EVENLY ALONG THE | | | TRAIL. | | | | | | | | | SHING TSOI | | | CITY IN-HOUSE TRAFFIC CONSULTANT | | | 561-494-1141 | | | [email protected] | | | (IN-HOUSE ON TUESDAYS AND WEDNESDAYS) | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
F |
Date |
01-27-2020 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
01-27-2020 |
Time |
16:44 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
01-27-2020 |
Time |
16:44 |
Sent To |
|
|
| Notes |
| 2020-01-27 16:44:34 | PLANS AND PLATS REVIEW COMMITTEE (PPRC) ZONING REVIEW | | | ________________________________________ | | | | | | DATE OF REVIEW: 01.27.2020 | | | PROJECT NO.: Z19090014 AND Z19090015 | | | CASE NO.: PB 1842 AND PB 1842A | | | ________________________________________ | | | | | | PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING | | | REVIEW COMMENTS: | | | | | | 1. [ NOT SATISFIED ] - APPROVAL LETTER FROM PALM BEACH | | | COUNTY SHALL BE PROVIDED INDICATING THAT THE PROJECT | | | COMPLIES WITH THE COUNTY TRAFFIC PERFORMANCE STANDARDS. | | | | | | 2. DID ALEX REVIEW THE UPDATED FLU TRAFFIC ANALYSIS? | | | | | | 3. [ NOT SATISFIED ] - UTILITY LETTER FROM COMCAST | | | SHALL BE PROVIDED. | | | | | | 4. [ SATISFIED ] - SOUTHBOUND LEFT TURN LANE REQUIRED | | | AT THE PRIMARY RESIDENTIAL ENTRANCE? WHAT IS THE IMPACT | | | ON THE EXISTING MEDIAN (TREES, ETC.)? WAS THIS REVIEWED | | | BY THE VILLAGES POA? | | | | | | 5. [ PARTIALLY SATISFIED ] - THE TRAFFIC ANALYSIS | | | INDICATES A VOLUNTARY RESTRICTION PROPOSED AT 30.5 | | | DU/ACRE? WHAT IF THE FLU IS CHANGED TO MFMD (MAX 20 | | | DU/ACRE) AND/OR THE RESTRICTION IS AT 14.52 DU/ACRE? | | | THIS WOULD BE CONSISTENT WITH THE UNDERLYING MF14 | | | ZONING DESIGNATION THAT IS PROPOSED. | | | | | | 5.1 [ NEW COMMENT ] ? IF THE APPLICANT IS NOT REVISING | | | THEIR REQUEST TO AMEND THE FUTURE LAND USE MAP TO MFMD | | | INSTEAD OF MF, THEN STAFF WILL BE RECOMMENDING A | | | CONDITION OF APPROVAL THAT REFLECTS SUCH REQUIREMENT | | | PRIOR TO SCHEDULING A PUBLIC HEARING BEFORE THE CITY | | | COMMISSION. | | | | | | 6. [ PARTIALLY SATISFIED ] - WHAT WERE THE CONCERNS OF | | | THE SPENCER LAKES HOA AND HOW ARE THEY BEING ADDRESSED? | | | | | | 6.1 [ NEW COMMENT ] ? IS FURTHER OUTREACH PROPOSED? IS | | | THE APPLICANT OF THE POSITION THAT THE RESIDENTS? | | | CONCERNS HAVE BEEN SATISFACTORILY ADDRESSED? | | | | | | 7. [ PARTIALLY SATISFIED ] - THE ZONING MAP ON THE | | | COVER SHEET OF THE ARCHITECTURAL PLANS SHOULD BE | | | UPDATED TO THE CITY OF WEST PALM BEACH?S MAP; DO NOT | | | USE PALM BEACH COUNTY?S AS THE CITY?S DESIGNATIONS ARE | | | NOT SPECIFIED. | | | | | | 7.1 [ NEW COMMENT ] ? THE ARCHITECT HAS PROVIDED FOR | | | THE CORRECT ZONING MAP, BUT IDENTIFIED THE PROJECT SITE | | | WITH ?MF-14?, WHICH IS NOT CORRECT. | | | | | | 8. [ SATISFIED ] - SHEET SP-1 WAS MISSING OUT OF THE | | | ARCHITECTURAL PDF. | | | | | | 9. [ SATISFIED ] - THE SITE PLAN SHALL SHOW THE ENTIRE | | | PROPERTY, INCLUDING THAT WHICH IS LAKE AREA. | | | | | | 10. [ SATISFIED ] - THE SITE PLAN SHOULD BE AT A LARGER | | | SCALE. IT?S OK TO HAVE THE OVERALL SITE PLAN AT SUCH A | | | SMALL SCALE, BUT A LARGER SCALE (MULTIPLE SHEETS WITH | | | MATCH LINES) NEEDS TO BE PROVIDED. | | | | | | 11. [ PARTIALLY SATISFIED ] - ALL DRIVE AISLES | | | CONTAINING PARKING ROWS ARE TO BE A MINIMUM OF 24 FEET | | | IN WIDTH; ONLY 22 FEET IS SHOWN. DRIVE AISLE THAT DO | | | NOT HAVE PARKING BACKING INTO THEM CAN BE NARROWER. | | | | | | 11.1 [ NEW COMMENT ] - THE SITE PLAN AND CIVIL PLANS | | | ARE SHOWING DIFFERENT DIMENSION FOR THE DRIVE AISLES, | | | ESPECIALLY AT THE FRONT ENTRANCE BEFORE THE GATES. IS | | | THE APPLICANT CONFIDENT THAT THE VEHICLE USED FOR THE | | | TURNING RADIUS ANALYSIS IS SUFFICIENT TO REPRESENT | | | ACTUAL USE OF THE PARKING LOT WITH THE REDUCED DRIVE | | | AISLES? | | | | | | 12. [ SATISFIED SUBJECT TO GRANTING OF WAIVER ] - | | | FENCING WITHIN THE FRONT SETBACK (25 FEET) SHALL NOT | | | EXCEED 4 FEET IN HEIGHT. | | | | | | 13. [ SATISFIED ] - DETAIL SHALL BE PROVIDED FOR ALL | | | FENCING. | | | | | | 14. [ SATISFIED ] - THE SITE PLAN SHOULD PROVIDE THE | | | REFERENCES FOR DETAILS THAT ARE PROVIDED. FOR EXAMPLE, | | | SHEET SP-1 SHOULD REFERENCE DETAIL #1, SHEET LH-7 FOR | | | THE MONUMENT SIGN AND DETAIL #2, SHEET LH-7 FOR THE | | | TRELLIS FEATURE. | | | | | | 15. [ SATISFIED ] - SETBACKS SHALL BE PROVIDED FOR THE | | | PROPOSED TRELLIS FEATURE. | | | | | | 16. [ SATISFIED ] - THE POOL NEEDS TO BE ENCLOSED BY A | | | CONTINUOUS FENCE OF AT LEAST 4 FEET IN HEIGHT WITH | | | SELF-CLOSING/SELF-LATCHING GATES. LATCHES SHALL BE AT | | | LEAST 54 INCHES ABOVE GRADE. | | | | | | 17. [ PARTIALLY SATISFIED ] - PLEASE EXPLAIN THE | | | FUNCTION OF THE MAIL KIOSK. WILL USPS HAVE ACCESS | | | INSIDE THE MAIN GATES AND BE ABLE TO PARK IN FRONT OF | | | THE KIOSK, OR ARE THEY EXPECTED TO PARK AT THE | | | CLUBHOUSE? | | | | | | 17.1 [ NEW COMMENT ] ? THERE APPEARS TO BE NOT SIDEWALK | | | ACCESSING THAT PORTION OF THE BUILDING THAT CONTAINS | | | THE MAIL BOXES. THE OPENING IN THE BUILDING FRONTS INTO | | | LANDSCAPE AREA. THERE NEEDS TO BE AN ACCESSIBLE ROUTE. | | | | | | 18. [ SATISFIED ] - BIKE RACKS SHALL BE PROVIDED FOR | | | BUILDING #6 AND THE CLUBHOUSE. | | | | | | 19. [ SATISFIED ] - THE JUSTIFICATION STATEMENT | | | INDICATES THAT THE NORTH DRIVEWAY (CROSS-ACCESS WITH | | | THE CHURCH) IS EMERGENCY EGRESS ONLY, BUT THE SITE PLAN | | | INDICATES AN ENTRANCE AS WELL AS AN EXIT; PLEASE | | | EXPLAIN. | | | | | | 20. [ NOT SATISFIED ] - IF THE INTENT IS THAT THE | | | COMMUNITY WOULD BE COMPLETELY ENCLOSED BY FENCING, | | | THERE ARE SEVERAL GAPS THAT DO ALLOW UNRESTRICTED | | | ACCESS. | | | | | | 20.1 [ NEW COMMENT ] ? NOTE THAT SOMEONE CAN ACCESS THE | | | PROPERTY BY WALKING AROUND THE SOUTHEAST SIDE OF THE | | | CLUBHOUSE (BY THE LAKE) AND CONTINUE ALONG THE LAKE | | | EDGE INTO THE REST OF THE DEVELOPMENT. | | | | | | 21. [ SATISFIED ] - SETBACKS SHALL BE PROVIDED FOR ALL | | | BUILDINGS WITHIN PROXIMITY TO A PROPERTY LINE. SETBACKS | | | WERE NOT SHOWN FOR THE CLUBHOUSE AND TRASH COMPACTOR. | | | | | | 22. [ SATISFIED ] - SHEET TC-1 WAS NOT PROVIDED. | | | | | | 23. [ PARTIALLY SATISFIED ] - DETAILS SHALL BE PROVIDED | | | FOR THE SCREENING AROUND THE PROPOSED LIFT STATION. | | | | | | 23.1 [ NEW COMMENT ] ? THE CONFIGURATION OF THE | | | COMPACTOR ON THE LANDSCAPE PLANS DOES NOT MATCH THAT | | | WHICH IS SHOWN ON THE SITE PLANS. ALL PLANS SHALL BE | | | CONSISTENT. ADDITIONALLY, STAFF WOULD LIKE TO WORK WITH | | | THE APPLICANT TO BETTER SCREEN THIS AREA AS THE | | | PROPOSED DESIGN LEAVES AN AREA THAT IS WIDE OPEN AND | | | NOT AESTHETICALLY DESIRABLE. | | | | | | 24. [ NOT SATISFIED ] - THE AREA AROUND THE TRASH | | | COMPACTOR NEEDS TO BE WORKED OUT IN MORE DETAIL. THERE | | | SEEMS TO BE CONSTRAINTS IN ACCESSING THE TRASH | | | COMPACTOR BASED UPON THE LOCATION OF THE LIFT STATION | | | SCREENING, ETC. | | | | | | 24.1 [ NEW COMMENT ] ? SEE COMMENT 23.1 ABOVE. | | | | | | 25. [ SATISFIED ] - A WALKWAY NEEDS TO BE PROVIDED ON | | | THE NORTHWEST SIDE OF THE DETACHED GARAGE NEAR BUILDING | | | #3 SO THAT THERE IS A CONTINUOUS ACCESSIBLE ROUTE TO | | | THE DOG PARK. | | | | | | 26. [ SATISFIED ] - AS REQUIRED BY THE DEVELOPMENT | | | APPLICATION, ALL SIDEWALKS SHALL BE DIMENSIONED. | | | PARTICULAR ATTENTION NEEDS TO OCCUR AT THOSE AREAS | | | WHERE THE VEHICLE OVERHANG OCCURS OVER THE SIDEWALK. | | | ENSURE THAT THE MINIMUM WIDTH OF THE ACCESSIBLE ROUTE | | | IS PROVIDED. | | | | | | 27. [ PARTIALLY SATISFIED ] - DETAILS SHALL BE PROVIDED | | | OF THE PROPOSED MONUMENT SIGN AT THE MAIN ENTRANCE. | | | | | | 27.1 [ NEW COMMENT ] ? ARCHITECTURAL DETAILS (CAPS ON | | | THE COLUMNS) SHALL NOT BE MORE THAN 10 PERCENT OF THE | | | MAXIMUM HEIGHT OF THE SIGN, WHICH IS 4 FEET. | | | | | | 28. [ SATISFIED ] - PLEASE PROVIDE INFORMATION | | | REGARDING THE TRASH COMPACTOR. THE MANEUVERABILITY PLAN | | | SHOWS A FRONT-LOADING DUMP TRUCK, BUT IF THE COMPACTOR | | | CONSISTS OF A LARGE ROLL-OFF DUMPSTER, THEN THE TRUCK | | | INFORMATION IS INCORRECT AND REQUIRES THAT IT BE LOADED | | | ONTO THE REAR OF THE VEHICLE. | | | | | | 29. [ SATISFIED ] - WHAT TYPE OF FIRE TRUCK WAS BEING | | | USED FOR THE MANEUVERABILITY PLAN. THERE IS POSSIBLE | | | CONCERN REGARDING THE ?CHICANE? THAT IS CREATED BY THE | | | ALIGNMENT OF THE NON-VISITOR DRIVE WITH THE MAIN | | | ENTRANCE GATE. | | | | | | 30. [ SATISFIED ] - DETAIL NEEDS TO BE PROVIDED | | | INDICATING THAT THE SIGNAGE REQUIRED FOR THE ACCESSIBLE | | | PARKING SPACES WILL NOT OCCUR WITHIN THE REQUIRED | | | OVERHANG, AND THAT IT WILL NOT ENCROACH INTO THE | | | REQUIRED ACCESSIBLE SIDEWALK. | | | | | | 31. [ SATISFIED ] - A TURNAROUND SPACE NEEDS TO BE | | | PROVIDED AT THE DEAD-END PARKING IN FRONT OF BUILDING | | | #4. | | | | | | 32. [ PARTIALLY SATISFIED ] - THE JUSTIFICATION | | | STATEMENT INDICATES THAT ONE OF THE ?INNOVATIVE? | | | FEATURES OF THE PROPOSED PROJECT IS THE USE OF CURBING | | | (INSTEAD OF WHEEL STOPS) TO INCREASE THE AMOUNT OF | | | LANDSCAPE AREA. ACTUALLY, MOST OF THE AREAS WHERE THIS | | | OCCURS, THE OVERHANG OCCURS OVER A SIDEWALK, NOT AN | | | EXPANDED LANDSCAPE AREA. THERE ARE A LOT OF AREAS WHERE | | | WHEEL STOPS ARE STILL BEING PROPOSED ADJACENT TO | | | LANDSCAPING, AND IT DOESN?T APPEAR THAT THIS IS | | | NECESSARY TO ACCOMMODATE DRAINAGE. | | | | | | 32.1 [ NEW COMMENT ] ? THE USE OF THE CURBS IS NOT | | | REQUIRED, BUT STAFF IS JUST EMPHASIZING THAT IF THIS IS | | | BEING USED AS AN ?INNOVATIVE? FEATURE, THERE ARE A | | | NUMBER OF AREAS ON THE SITE WHERE THIS IS NOT BEING | | | DONE, BUT COULD BE. | | | | | | 33. [ SATISFIED ] - THE DIMENSIONS ON THE BUILDING | | | ELEVATIONS ARE INCORRECT. THE DIMENSIONS BETWEEN THE | | | LEVELS DO NOT CORRESPOND WITH THE ELEVATION DIMENSIONS. | | | FOR EXAMPLE, THE PLANS INDICATE 12 FEET 8 INCHES | | | BETWEEN THE TOP OF BEAM AND THE TOP OF RIDGE, BUT THE | | | ELEVATIONS GIVEN SHOW A 13 FOOT 2 INCH DIFFERENCE. | | | | | | 34. [ SATISFIED ] - THE DATA TABLE INDICATES THAT | | | BICYCLE PARKING IS REQUIRED FOR EVERY 15 PARKING | | | SPACES, BUT THE ZLDRS ONLY REQUIRE 1 BICYCLE SPACE FOR | | | EVERY 20 PARKING SPACES. | | | | | | 35. [ SATISFIED ] - THE JUSTIFICATION STATEMENT | | | INDICATES THAT 550 PARKING SPACES ARE BEING PROVIDED, | | | BUT SHEET SP-1 INDICATES 556. ENSURE THAT ALL PLANS AND | | | NARRATIVES ARE CONSISTENT. | | | | | | 36. [ PARTIALLY SATISFIED ] - PARKING DETAIL SHALL BE | | | PROVIDED. | | | | | | 36.1 [ NEW COMMENT ] ? DETAIL SHALL PROVIDE THE | | | DIMENSION OF THE STRIPING. | | | | | | 37. [ SATISFIED ] - LANDSCAPE TERMINAL ISLAND NORTH OF | | | BUILDING #6, AT THE WEST END OF THE 7 PARKING SPACES, | | | DOES NOT MEET THE MINIMUM DIMENSIONAL/LANDSCAPING | | | REQUIREMENTS. | | | | | | 38. [ SATISFIED ] - TERMINAL LANDSCAPE ISLAND ARE TO BE | | | PROVIDED BETWEEN THE GARAGES AND THE ADJACENT PARKING | | | ROWS. | | | | | | 39. [ NEW COMMENT ] ? THERE IS A LIGHT POLE IN THE | | | MIDDLE OF THE SIDEWALK, JUST INSIDE THE TRELLIS BY THE | | | CLUBHOUSE. | | | ________________________________________ | | | | | | PLEASE NOTE THE FOLLOWING WHEN RESUBMITTING: | | | | | | A) WRITTEN RESPONSES TO COMMENTS MADE BY ALL | | | DEPARTMENTS SHALL BE PROVIDED UPON RESUBMISSION. | | | | | | B) 15 SETS OF REVISED PLANS AND/OR DOCUMENTS SHALL BE | | | PROVIDED, ALONG WITH ONE (1) REDUCED COPY (11IN X | | | 17IN), AND AN ELECTRONIC COPY OF ALL PLANS. | | | | | | C) PLEASE NOTE THAT RE-SUBMITTALS MAY BE SUBJECT TO | | | ADDITIONAL COMMENTS. | | | | | | D) IF NO RESPONSE IS RECEIVED WITHIN 60 DAYS OF THE | | | ISSUANCE OF THESE COMMENTS, THE APPLICATION WILL BE | | | CONSIDERED WITHDRAWN AND ANY FURTHER ACTION WILL | | | REQUIRE SUBMISSION OF A NEW DEVELOPMENT APPLICATION. | | | | | | E) PLEASE NOTE THAT YOU WILL BE PERMITTED ONE (1) | | | RESUBMITTAL AT NO ADDITIONAL COST. IF PREVIOUSLY-ISSUED | | | COMMENTS CONTINUE TO NOT BE SUFFICIENTLY ADDRESSED, THE | | | APPLICANT WILL BE ACCESSED A RESUBMITTAL FEE. SUCH FEE | | | WILL BE 20% OF THE ORIGINAL APPLICATION FEE. | | | | | | F) IN ORDER TO BE CONSIDERED FOR THE FEBRUARY 18, 2020, | | | PLANNING BOARD AGENDA, ALL COMMENTS SHALL BE | | | SATISFACTORILY ADDRESSED. PLEASE SUBMIT ALL REVISED | | | DOCUMENTS/PLANS NO LATER THAN FEBRUARY 3, 2020. | | | | | | G) TO BE PLACED ON THE FEBRUARY 18, 2020, PLANNING | | | BOARD AGENDA, SIGNS SHALL BE POSTED ON THE PROPERTY NO | | | LATER THAN FEBRUARY 3, 2020. SIGNAGE SHALL CONFORM, AND | | | BE INSTALLED ACCORDING TO THE REQUIREMENTS OF THE | | | CITY?S ZONING AND LAND DEVELOPMENT REGULATIONS; SUCH | | | REQUIREMENTS ARE ALSO PROVIDED IN THE DEVELOPMENT | | | APPLICATION. A SIGNED AND NOTARIZED AFFIDAVIT SHALL BE | | | PROVIDED BY THE DEADLINE REFERENCED ABOVE. | | | | | | H) IF AFTER THE CASE HAS BEEN ADVERTISED THE APPLICANT | | | DESIRES TO REQUEST A CONTINUANCE, A FEE OF $50 PLUS THE | | | COST OF ADVERTISING WILL BE CHARGED. | | | ________________________________________ | | | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | | | JOHN P. ROACH, AICP, PRINCIPAL PLANNER | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION | | | 401 CLEMATIS STREET - P.O. BOX 3147 | | | WEST PALM BEACH, FLORIDA 33402 | | | | | | P: 561.822.1448 | | | TTY: 800.955.8771 | | | E: [email protected] | | | | | | W: WPB.ORG | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
12-18-2019 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
12-18-2019 |
Time |
13:32 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
12-18-2019 |
Time |
13:31 |
Sent To |
|
|
| Notes |
| 2019-12-18 13:32:31 | PLANS AND PLATS REVIEW COMMITTEE (PPRC) ZONING REVIEW | | | ________________________________________ | | | | | | DATE OF REVIEW: 12.18.2019 | | | PROJECT NO.: Z19090014 AND Z19090015 | | | CASE NO.: PB 1842 AND PB 1842A | | | ________________________________________ | | | | | | PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING | | | REVIEW COMMENTS: | | | | | | 1. APPROVAL LETTER FROM PALM BEACH COUNTY SHALL BE | | | PROVIDED INDICATING THAT THE PROJECT COMPLIES WITH THE | | | COUNTY TRAFFIC PERFORMANCE STANDARDS. | | | | | | 2. DID ALEX REVIEW THE UPDATED FLU TRAFFIC ANALYSIS? | | | | | | 3. UTILITY LETTER FROM COMCAST SHALL BE PROVIDED. | | | | | | 4. SOUTHBOUND LEFT TURN LANE REQUIRED AT THE PRIMARY | | | RESIDENTIAL ENTRANCE?WHAT IS THE IMPACT ON THE EXISTING | | | MEDIAN (TREES, ETC.)? WAS THIS REVIEWED BY THE VILLAGES | | | POA? | | | | | | 5. THE TRAFFIC ANALYSIS INDICATES A VOLUNTARY | | | RESTRICTION PROPOSED AT 30.5 DU/ACRE?WHAT IF THE FLU IS | | | CHANGED TO MFMD (MAX 20 DU/ACRE) AND/OR THE RESTRICTION | | | IS AT 14.52 DU/ACRE? THIS WOULD BE CONSISTENT WITH THE | | | UNDERLYING MF14 ZONING DESIGNATION THAT IS PROPOSED. | | | | | | 6. WHAT WERE THE CONCERNS OF THE SPENCER LAKES HOA AND | | | HOW ARE THEY BEING ADDRESSED? | | | | | | 7. THE ZONING MAP ON THE COVER SHEET OF THE | | | ARCHITECTURAL PLANS SHOULD BE UPDATED TO THE CITY OF | | | WEST PALM BEACH?S MAP; DO NOT USE PALM BEACH COUNTY?S | | | AS THE CITY?S DESIGNATIONS ARE NOT SPECIFIED. | | | | | | 8. SHEET SP-1 WAS MISSING OUT OF THE ARCHITECTURAL PDF. | | | | | | 9. THE SITE PLAN SHALL SHOW THE ENTIRE PROPERTY, | | | INCLUDING THAT WHICH IS LAKE AREA. | | | | | | 10. THE SITE PLAN SHOULD BE AT A LARGER SCALE. IT?S OK | | | TO HAVE THE OVERALL SITE PLAN AT SUCH A SMALL SCALE, | | | BUT A LARGER SCALE (MULTIPLE SHEETS WITH MATCH LINES) | | | NEEDS TO BE PROVIDED. | | | | | | 11. ALL DRIVE AISLES CONTAINING PARKING ROWS ARE TO BE | | | A MINIMUM OF 24 FEET IN WIDTH; ONLY 22 FEET IS SHOWN. | | | DRIVE AISLE THAT DO NOT HAVE PARKING BACKING INTO THEM | | | CAN BE NARROWER. | | | | | | 12. FENCING WITHIN THE FRONT SETBACK (25 FEET) SHALL | | | NOT EXCEED 4 FEET IN HEIGHT. | | | | | | 13. DETAIL SHALL BE PROVIDED FOR ALL FENCING. | | | | | | 14. THE SITE PLAN SHOULD PROVIDE THE REFERENCES FOR | | | DETAILS THAT ARE PROVIDED. FOR EXAMPLE, SHEET SP-1 | | | SHOULD REFERENCE DETAIL #1, SHEET LH-7 FOR THE MONUMENT | | | SIGN AND DETAIL #2, SHEET LH-7 FOR THE TRELLIS FEATURE. | | | | | | 15. SETBACKS SHALL BE PROVIDED FOR THE PROPOSED TRELLIS | | | FEATURE. | | | | | | 16. THE POOL NEEDS TO BE ENCLOSED BY A CONTINUOUS FENCE | | | OF AT LEAST 4 FEET IN HEIGHT WITH | | | SELF-CLOSING/SELF-LATCHING GATES. LATCHES SHALL BE AT | | | LEAST 54 INCHES ABOVE GRADE. | | | | | | 17. PLEASE EXPLAIN THE FUNCTION OF THE MAIL KIOSK. WILL | | | USPS HAVE ACCESS INSIDE THE MAIN GATES AND BE ABLE TO | | | PARK IN FRONT OF THE KIOSK, OR ARE THEY EXPECTED TO | | | PARK AT THE CLUBHOUSE? | | | | | | 18. BIKE RACKS SHALL BE PROVIDED FOR BUILDING #6 AND | | | THE CLUBHOUSE. | | | | | | 19. THE JUSTIFICATION STATEMENT INDICATES THAT THE | | | NORTH DRIVEWAY (CROSS-ACCESS WITH THE CHURCH) IS | | | EMERGENCY EGRESS ONLY?BUT THE SITE PLAN INDICATES AN | | | ENTRANCE AS WELL AS AN EXIT; PLEASE EXPLAIN. | | | | | | 20. IF THE INTENT IS THAT THE COMMUNITY WOULD BE | | | COMPLETELY ENCLOSED BY FENCING, THERE ARE SEVERAL GAPS | | | THAT DO ALLOW UNRESTRICTED ACCESS. | | | | | | 21. SETBACKS SHALL BE PROVIDED FOR ALL BUILDINGS WITHIN | | | PROXIMITY TO A PROPERTY LINE. SETBACKS WERE NOT SHOWN | | | FOR THE CLUBHOUSE AND TRASH COMPACTOR. | | | | | | 22. SHEET TC-1 WAS NOT PROVIDED. | | | | | | 23. DETAILS SHALL BE PROVIDED FOR THE SCREENING AROUND | | | THE PROPOSED LIFT STATION. | | | | | | 24. THE AREA AROUND THE TRASH COMPACTOR NEEDS TO BE | | | WORKED OUT IN MORE DETAIL. THERE SEEMS TO BE | | | CONSTRAINTS IN ACCESSING THE TRASH COMPACTOR BASED UPON | | | THE LOCATION OF THE LIFT STATION SCREENING, ETC. | | | | | | 25. A WALKWAY NEEDS TO BE PROVIDED ON THE NORTHWEST | | | SIDE OF THE DETACHED GARAGE NEAR BUILDING #3 SO THAT | | | THERE IS A CONTINUOUS ACCESSIBLE ROUTE TO THE DOG PARK. | | | | | | 26. AS REQUIRED BY THE DEVELOPMENT APPLICATION, ALL | | | SIDEWALKS SHALL BE DIMENSIONED. PARTICULAR ATTENTION | | | NEEDS TO OCCUR AT THOSE AREAS WHERE THE VEHICLE | | | OVERHANG OCCURS OVER THE SIDEWALK. ENSURE THAT THE | | | MINIMUM WIDTH OF THE ACCESSIBLE ROUTE IS PROVIDED. | | | | | | 27. DETAILS SHALL BE PROVIDED OF THE PROPOSED MONUMENT | | | SIGN AT THE MAIN ENTRANCE. | | | | | | 28. PLEASE PROVIDE INFORMATION REGARDING THE TRASH | | | COMPACTOR. THE MANEUVERABILITY PLAN SHOWS A | | | FRONT-LOADING DUMP TRUCK?BUT IF THE COMPACTOR CONSISTS | | | OF A LARGE ROLL-OFF DUMPSTER, THEN THE TRUCK | | | INFORMATION IS INCORRECT AND REQUIRES THAT IT BE LOADED | | | ONTO THE REAR OF THE VEHICLE. | | | | | | 29. WHAT TYPE OF FIRE TRUCK WAS BEING USED FOR THE | | | MANEUVERABILITY PLAN. THERE IS POSSIBLE CONCERN | | | REGARDING THE ?CHICANE? THAT IS CREATED BY THE | | | ALIGNMENT OF THE NON-VISITOR DRIVE WITH THE MAIN | | | ENTRANCE GATE. | | | | | | 30. DETAIL NEEDS TO BE PROVIDED INDICATING THAT THE | | | SIGNAGE REQUIRED FOR THE ACCESSIBLE PARKING SPACES WILL | | | NOT OCCUR WITHIN THE REQUIRED OVERHANG, AND THAT IT | | | WILL NOT ENCROACH INTO THE REQUIRED ACCESSIBLE | | | SIDEWALK. | | | | | | 31. A TURNAROUND SPACE NEEDS TO BE PROVIDED AT THE | | | DEAD-END PARKING IN FRONT OF BUILDING #4. | | | | | | 32. THE JUSTIFICATION STATEMENT INDICATES THAT ONE OF | | | THE ?INNOVATIVE? FEATURES OF THE PROPOSED PROJECT IS | | | THE USE OF CURBING (INSTEAD OF WHEEL STOPS) TO INCREASE | | | THE AMOUNT OF LANDSCAPE AREA. ACTUALLY, MOST OF THE | | | AREAS WHERE THIS OCCURS, THE OVERHANG OCCURS OVER A | | | SIDEWALK, NOT AN EXPANDED LANDSCAPE AREA. THERE ARE A | | | LOT OF AREAS WHERE WHEEL STOPS ARE STILL BEING PROPOSED | | | ADJACENT TO LANDSCAPING, AND IT DOESN?T APPEAR THAT | | | THIS IS NECESSARY TO ACCOMMODATE DRAINAGE. | | | | | | 33. THE DIMENSIONS ON THE BUILDING ELEVATIONS ARE | | | INCORRECT. THE DIMENSIONS BETWEEN THE LEVELS DO NOT | | | CORRESPOND WITH THE ELEVATION DIMENSIONS. FOR EXAMPLE, | | | THE PLANS INDICATE 12? 8? BETWEEN THE TOP OF BEAM AND | | | THE TOP OF RIDGE, BUT THE ELEVATIONS GIVEN SHOW A 13? | | | 2? DIFFERENCE. | | | | | | 34. THE DATA TABLE INDICATES THAT BICYCLE PARKING IS | | | REQUIRED FOR EVERY 15 PARKING SPACES, BUT THE ZLDRS | | | ONLY REQUIRE 1 BICYCLE SPACE FOR EVERY 20 PARKING | | | SPACES. | | | | | | 35. THE JUSTIFICATION STATEMENT INDICATES THAT 550 | | | PARKING SPACES ARE BEING PROVIDED, BUT SHEET SP-1 | | | INDICATES 556. ENSURE THAT ALL PLANS AND NARRATIVES ARE | | | CONSISTENT. | | | | | | 36. PARKING DETAIL SHALL BE PROVIDED. | | | | | | 37. LANDSCAPE TERMINAL ISLAND NORTH OF BUILDING #6, AT | | | THE WEST END OF THE 7 PARKING SPACES, DOES NOT MEET THE | | | MINIMUM DIMENSIONAL/LANDSCAPING REQUIREMENTS. | | | | | | 38. TERMINAL LANDSCAPE ISLAND ARE TO BE PROVIDED | | | BETWEEN THE GARAGES AND THE ADJACENT PARKING ROWS. | | | ________________________________________ | | | | | | PLEASE NOTE THE FOLLOWING WHEN RESUBMITTING: | | | | | | A) WRITTEN RESPONSES TO COMMENTS MADE BY ALL | | | DEPARTMENTS SHALL BE PROVIDED UPON RESUBMISSION. | | | | | | B) 15 SETS OF REVISED PLANS AND/OR DOCUMENTS SHALL BE | | | PROVIDED, ALONG WITH ONE (1) REDUCED COPY (11IN X | | | 17IN), AND AN ELECTRONIC COPY OF ALL PLANS. | | | | | | C) PLEASE NOTE THAT RE-SUBMITTALS MAY BE SUBJECT TO | | | ADDITIONAL COMMENTS. | | | | | | D) IF NO RESPONSE IS RECEIVED WITHIN 60 DAYS OF THE | | | ISSUANCE OF THESE COMMENTS, THE APPLICATION WILL BE | | | CONSIDERED WITHDRAWN AND ANY FURTHER ACTION WILL | | | REQUIRE SUBMISSION OF A NEW DEVELOPMENT APPLICATION. | | | | | | E) PLEASE NOTE THAT YOU WILL BE PERMITTED ONE (1) | | | RESUBMITTAL AT NO ADDITIONAL COST. IF PREVIOUSLY-ISSUED | | | COMMENTS CONTINUE TO NOT BE SUFFICIENTLY ADDRESSED, THE | | | APPLICANT WILL BE ACCESSED A RESUBMITTAL FEE. SUCH FEE | | | WILL BE 20% OF THE ORIGINAL APPLICATION FEE. | | | | | | F) IN ORDER TO BE CONSIDERED FOR THE FEBRUARY 18, 2020, | | | PLANNING BOARD AGENDA, ALL COMMENTS SHALL BE | | | SATISFACTORILY ADDRESSED. PLEASE SUBMIT ALL REVISED | | | DOCUMENTS/PLANS NO LATER THAN JANUARY 10, 2020. | | | | | | G) TO BE PLACED ON THE FEBRUARY 18, 2020, PLANNING | | | BOARD AGENDA, SIGNS SHALL BE POSTED ON THE PROPERTY NO | | | LATER THAN FEBRUARY 3, 2020. SIGNAGE SHALL CONFORM, AND | | | BE INSTALLED ACCORDING TO THE REQUIREMENTS OF THE | | | CITY?S ZONING AND LAND DEVELOPMENT REGULATIONS; SUCH | | | REQUIREMENTS ARE ALSO PROVIDED IN THE DEVELOPMENT | | | APPLICATION. A SIGNED AND NOTARIZED AFFIDAVIT SHALL BE | | | PROVIDED BY THE DEADLINE REFERENCED ABOVE. | | | | | | H) IF AFTER THE CASE HAS BEEN ADVERTISED THE APPLICANT | | | DESIRES TO REQUEST A CONTINUANCE, A FEE OF $50 PLUS THE | | | COST OF ADVERTISING WILL BE CHARGED. | | | ________________________________________ | | | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | | | JOHN P. ROACH, AICP, PRINCIPAL PLANNER | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION | | | 401 CLEMATIS STREET - P.O. BOX 3147 | | | WEST PALM BEACH, FLORIDA 33402 | | | | | | P: 561.822.1448 | | | TTY: 800.955.8771 | | | E: [email protected] | | | | | | W: WPB.ORG | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
10-09-2019 |
|
|
Cont ID |
|
| Sent By |
|
Date |
10-09-2019 |
Time |
|
Rev Time |
0.00 |
| Received By |
pgreilic |
Date |
10-09-2019 |
Time |
16:37 |
Sent To |
|
|
| Notes |
| 2019-10-09 16:37:24 | CASE NUMBER: PB 1842 & 1842A (Z19090014/5) | | | PROJECT NAME: BROADSTONE LAKESIDE REZONING AND FUTURE | | | LAND USE MAP AMENDMENT | | | ADDRESS: 3600 VILLAGE BOULEVARD | | | | | | ---CONTACT PAUL GREILICH @ (561) 822-1443 OR JOHN ROACH | | | @ 561-822-1448 | | | ---PLEASE PROVIDE RESPONSES TO REVIEW COMMENTS IN | | | WRITTEN FORMAT. | | | ---WHEN RESUBMITTING, PLEASE PROVIDE A MINIMUM OF | | | ELEVEN (11) PAPER COPIES AND AN ELECTRONIC COPY IN | | | .PNG/.PDF FORMAT OF ALL PLANS. PLEASE NOTE THAT CHANGES | | | ON THE RESUBMITTED PLANS OR THE SUBMITTAL OF | | | INFORMATION/PLANS TO ADDRESS THE COMMENTS MAY RESULT IN | | | ADDITIONAL COMMENTS. | | | ---PLEASE NOTE THAT IF THE PLANNING DIVISION HAS NOT | | | RECEIVED A RESPONSE TO THE PPRC COMMENTS WITHIN 60 DAYS | | | FROM THE DATE OF THESE COMMENTS/THE PPRC MEETING (BY | | | 7/8/19), THE CASE SHALL BE CONSIDERED WITHDRAWN. ANY | | | FURTHER ACTION SHALL REQUIRE A NEW DEVELOPMENT | | | APPLICATION. | | | ---PUBLIC HEARING NOTIFICATION SIGNAGE SHALL BE POSTED | | | IN ACCORDANCE WITH THE REQUIREMENTS OF SECTION | | | 94-39(I)(5) OF THE ZONING AND LAND DEVELOPMENT | | | REGULATIONS. | | | | | | 1) PROVIDE AN EXPLANATION OF HOW THE APPLICATION AS | | | PRESENTED MEETS THE INTENT OF SEC. 94-207(A)(1), | | | INNOVATIVE LAND PLANNING AND DEVELOPMENT TECHNIQUES. | | | | | | 2) IT IS UNCLEAR WHERE THE EDGE OF THE PROPOSED | | | LAKE/RETENTION POND IS BEING PROPOSED ALONG PERIMETER | | | OF THE SITE. PLEASE CLEARLY LABEL THE EDGE OF WATER AND | | | ANY ASSOCIATED EASEMENTS THROUGHOUT ON THE SITE PLAN. | | | | | | 3) THE 5-WAY INTERSECTION BEING PROPOSED TO THE | | | NORTHWEST OF BUILDING 6 WILL LIKELY CREATE CONFUSION | | | AND UNNECESSARY CONFLICTS. APPLICANT SHOULD EXPLORE THE | | | INCLUSION OF A ROUNDABOUT IN THIS LOCATION IN THE EVENT | | | THIS GENERAL DESIGN IS RETAINED. | | | | | | 4) ENHANCE INTERNAL PEDESTRIAN CIRCULATION AND | | | CONNECTIVITY THROUGHOUT THE SITE (DESIGNATED WALKS, | | | STRATEGICALLY PLACED CROSSWALKS, ETC.). STAFF STRONGLY | | | RECOMMENDS A MORE THOUGHTFUL CONSIDERATION OF THE SITE | | | AND IMPROVED DESIGN THAT BETTER INTEGRATES PARKING | | | AREAS, THE INCLUSION OF LOW COST AMENITIES SUCH AS | | | SMALL PARKS AND GATHERING SPACE. | | | | | | 5) COMPLETE WALKING PATHS AROUND THE PERIMETER OF THE | | | SITE TO ENABLE RESIDENTS TO WALK IN A CIRCUIT AND REACH | | | THE POOL AREA WITHOUT MEANDERING IF FRONT OF BUILDINGS. | | | WHERE POSSIBLE, WALKING PATHS SHOULD BE WIDER THAN 5 | | | FEET. | | | | | | 6) PROVIDE A DIRECT PEDESTRIAN PATH (SIDEWALK, STRIPING | | | OR BOTH) TO THE DOG PARK TO ALLOW SAFE AND EFFICIENT | | | ACCESS | | | | | | 7) DISTRIBUTE PARKING MORE CONVENIENTLY THROUGHOUT THE | | | SITE TO MINIMIZE CONFLICTS BETWEEN PEDESTRIANS AND | | | MOTORISTS AND REDUCE THE DISTANCE RESIDENTS WILL TRAVEL | | | TO THEIR UNITS FROM THE PARKING AREAS. | | | | | | 8) LABEL DIMENSIONS OF PARKING SPACES, DRIVE AISLES, | | | DRIVEWAYS, SIDEWALKS, ETC. | | | | | | 9) PLEASE PROVIDE AN OVERALL SITE PLAN WHICH | | | INCORPORATES THE PROPOSED IMPROVEMENTS AS PART OF THE | | | APPLICATION SUBMITTED CONCURRENTLY, PB1841 & 1841A ? | | | Z19090012/3. | | | | | | 10) CONSISTENT WITH RECENTLY APPROVED PROJECTS IN THE | | | CITY, STAFF SUPPORTS NARROWING DRIVE AISLES (TO AS FEW | | | AS 20 FEET). DOING SO WILL MINIMIZE OVERALL IMPERVIOUS | | | SURFACE, INCREASE LANDSCAPING IN TERMINAL ISLANDS AND | | | SLOW VEHICLES TO HELP MINIMIZE CONFLICTS AT PROPOSED | | | INTERSECTIONS. | | | | | | 11) STAFF SUPPORTS REDUCING THE DEPTH OF PARKING SPACES | | | BY INCLUDING A 2-FOOT GRASS OVERHANG. THE CURB WOULD | | | FUNCTION AS WHEEL STOPS. ALSO CONSIDER THE INCLUSION OF | | | SMALL CAR SPACES TO REDUCE OVERALL IMPERVIOUS SURFACE | | | AREA. | | | | | | 12) ADD REQUIRED BICYCLE PARKING SPACES AND DISTRIBUTE | | | THROUGHOUT THE SITE AND INCLUDE CITY-STANDARD BIKE RACK | | | DETAIL. | | | | | | 13) PURSUANT TO SEC. 94-207(5), ALL UTILITIES, | | | INCLUDING TELEPHONE, CABLE TELEVISION, AND ELECTRICAL | | | SERVICE SYSTEMS, SHALL BE INSTALLED UNDERGROUND. | | | | | | 14) A REPLAT OF THE SUBJECT PROPERTIES WILL BE | | | REQUIRED. | | | | | | 15) PROVIDE LETTERS FROM ALL OF THE FOLLOWING PUBLIC | | | UTILITIES CONFIRMING THAT THE PROPOSED PROJECT DOES NOT | | | ENCROACH INTO THEIR EASEMENTS OR OTHERWISE INTERFERE | | | WITH THE PROVISION OF THEIR SERVICES: AT&T, FPU, FPL, | | | AND COMCAST. | | | | | | 16) ALL PRIVATE DEVELOPMENT PROJECTS, INCLUDING NEW | | | CONSTRUCTION, OR THE RENOVATION OR IMPROVEMENT OF AN | | | EXISTING BUILDING, WHERE THE TOTAL CONSTRUCTION COSTS | | | ARE EQUAL OR GREATER THAN $750,000 IS SUBJECT TO THE | | | ART IN PUBLIC PLACES REQUIREMENTS OF CHAPTER 78, | | | ARTICLE V, OF THE CITY?S CODE OF ORDINANCES. CONTACT | | | SYBILLE WELTER @ 561-822-1521 OR [email protected] FOR | | | ADDITIONAL INFORMATION. | | | | | | 17) A TRAFFIC PERFORMANCE STANDARDS (TPS) REVIEW LETTER | | | FROM THE PALM BEACH COUNTY TRAFFIC DIVISION, VERIFYING | | | THAT THE PROJECT MEETS THE TPS STANDARDS OF THE COUNTY | | | WILL BE REQUIRED. | | | | | | 18) A SCHOOL CAPACITY AVAILABILITY DETERMINATION (SCAD) | | | WILL BE REQUIRED. | | | | | | 19) ADDITIONAL WAIVERS MAY NEED TO BE REQUESTED IN THE | | | EVENT THAT PROVISIONS OF THE CITY?S ZONING AND LAND | | | DEVELOPMENT REGULATIONS CANNOT BE SATISFIED. | | | SPECIFICALLY, LANDSCAPE BUFFERS AS PROPOSED DO NOT MEET | | | REQUIREMENTS OF ARTICLE XIV. | | | | | | | | | | | | |
|
|
| |