Plan Review Details - Project Z19090013
| Plan Review Stops For Project Z19090013 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
10-09-2019 |
|
|
Cont ID |
|
| Sent By |
rbrown |
Date |
10-09-2019 |
Time |
19:58 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
10-09-2019 |
Time |
19:58 |
Sent To |
|
|
| Notes |
| 2019-10-09 20:01:14 | DEVELOPMENT SERVICES DEPARTMENT, BUILDING DIVISION: | | | | | | NO COMMENT ON THE PROPOSED REZONING. SEE PROJECT # | | | Z19090015 FOR COMMENTS ON THE PROPOSED APARTRMENT | | | COMPLEX CONSTRUCTION. |
|
|
| Review Stop |
ENG - PPRC |
ENGINEERING - PPRC |
| Rev No |
2 |
Status |
P |
Date |
12-04-2019 |
|
|
Cont ID |
|
| Sent By |
rrossano |
Date |
12-04-2019 |
Time |
|
Rev Time |
1.00 |
| Received By |
rrossano |
Date |
12-04-2019 |
Time |
|
Sent To |
|
|
| Notes |
| 2019-12-04 07:24:29 | PASSED WITH PROVISO: | | | | | | FOR FORMAL ENGINEERING SUBMITTAL, SHOW PROPOSED DCDA ON | | | PRIVATE PROPERTY. |
|
|
| Review Stop |
ENG - PPRC |
ENGINEERING - PPRC |
| Rev No |
1 |
Status |
F |
Date |
10-07-2019 |
|
|
Cont ID |
|
| Sent By |
rrossano |
Date |
10-07-2019 |
Time |
|
Rev Time |
|
| Received By |
rrossano |
Date |
10-07-2019 |
Time |
|
Sent To |
|
|
| Notes |
| 2019-10-07 11:58:24 | 1. THE CITY OF WEST PALM BEACH HAS A NUMBER OF | | | REGULATIONS AND PERMIT REQUIREMENTS WHICH DIRECTLY | | | AFFECT THE DEVELOPMENT AND INSTALLATION OF WATER AND | | | WASTEWATER UTILITIES WITHIN THE CITY. PLEASE SEE | | | DEVELOPMENT PERMIT SUBMITTAL REQUIREMENTS AT THE LINK | | | BELOW: HTTP://WPB.ORG/CMSPAGES/GETAMAZONFILE.ASPX?PATH= | | | ~\WPB_WEBSITE\MEDIA\ENGINEERING\DEVELOPMENT-APPLICATION | | | -FULL-PACKAGE_2016.PDF&HASH=7BD4DD7EB6115181D8C5977BCC0 | | | 2A97B1960045731D3658206F27451722716EF | | | THIS AND OTHER RELATED ENGINEERING DOCUMENTS CAN BE | | | FOUND HERE: HTTP://WPB.ORG/DEPARTMENTS/ENGINEERING-PUBL | | | IC-WORKS/FORMS,-PERMITS-APPLICATIONS | | | 2. CODE OF ORDINANCES, CITY OF WEST PALM BEACH, | | | FLORIDA, CODIFIED THROUGH ORD. NO. 4183-08, ADOPTED | | | SEPT. 22, 2008. (SUPPLEMENT NO. 18) | | | CHAPTER 90 UTILITIES, ARTICLE I. SEC. 90-7. | | | POLICY REGARDING EXTENSION OF WATER OR SEWER SERVICE | | | FACILITIES OF THE CITY. | | | THE WATER AND WASTEWATER SERVICE AGREEMENTS AND THE | | | CONSTRUCTION PERMITS ADDRESS RESERVATION OF CAPACITY | | | BASED ON USAGE, METER SIZE AND FEES, DESIGN STANDARDS, | | | BACKFLOW PREVENTION, FIRE SERVICE AND IRRIGATION. | | | 3. AS OF DECEMBER 20, 2015, THE CITY OF WEST PALM BEACH | | | CROSS-CONNECTION CONTROL MANUAL HAS BEEN REVISED, | | | STATING "ALL BACKFLOW DEVICES MUST BE LEAD-FREE". FOR | | | MORE INFORMATION, REFER TO THE LINK BELOW: | | | HTTP://WPB.ORG/DEPARTMENTS/PUBLIC-UTILITIES/FORMS-PUBLI | | | CATIONS/BACKFLOW-CROSS-CONNECTION-CONTROL-MANUAL | | | 4. PLANS SHALL SHOW PROPOSED LOCATIONS AND DIMENSIONS | | | OF ALL WATER, STORMWATER, AND SANITARY AND SEWER LINES, | | | INCLUDING STUBS TO EACH PROPERTY LINE FOR WATER AND | | | SANITARY SEWERS, THE MAKE AND MODEL OF ALL VALVES, | | | METERS, AND OTHERS DEVICES TO BE INSTALLED ON THE | | | SYSTEM, CATCH BASINS, CULVERTS, DITCHES INCLUDING | | | GRADES, PIPES SIZES, MATERIALS, ELEVATIONS, | | | ASSUMPTIONS, CALCULATIONS, INVERT ELEVATIONS FOR ALL | | | INLETS AND MANHOLES AND PROFILES OF SANITARY SEWER | | | LINES. ALL AVAILABLE ELEVATION SHALL BE SHOWN ON THE | | | PROFILE VIEW. DIRECTION OF FLOW SHALL BE SHOWN ON PLAN | | | VIEW ON PLAN VIEW FOR ALL SANITARY AND STORM SEWERS. | | | ADDITIONALLY, PLAN VIEW SHALL SHOW ALL EXISTING AND | | | PROPOSED UNDERGROUND UTILITY LAYOUT, INCLUDING FIBER | | | OPTIC, ELECTRIC, GAS, AND CABLEVISION & | | | TELECOMMUNICATION FACILITIES LOCATED ON THE | | | RIGHT-OF-WAY. PROVIDE PROFILE AND CLEARANCES AT ALL | | | UTILITY CROSSINGS. | | | 5. CUT AND CAP UTILITIES NOT IN USE, AND REMOVE ANY | | | ABANDONED UTILITY LINES LARGER THAN 2 INCHES FROM CITY | | | RIGHT OF WAY. | | | 6. PLEASE SUBMIT COMPLETED LOS ANALYSIS SUMMARY TABLE | | | DIRECTLY TO ENGINEERING (SHEET 33 OF CITY OF WPB | | | DEVELOPMENT APPLICATION). | | | 7. PROVIDE CALCULATIONS ON PLANS OF EXISTING AND | | | PROPOSED DEMANDS FOR WATER & SEWER (AVERAGE, MAXIMUM | | | AND PEAK) AND FIRE FLOW DEMANDS. CALCULATIONS SHALL BE | | | PER FAC 64E-6 FOR SEWER AND PER FAC 64-E.008 FOR WATER. | | | 8. SHOW VERTICAL DATUM AND DATUM CONVERSION INFORMATION | | | (NAVD 88 AND NGVD 29) ON ALL SHEETS. | | | 9. PLEASE PROVIDE CALCULATIONS OF EXISTING AND REVISED | | | PERVIOUS AND IMPERVIOUS CALCULATIONS FOR THE PROPOSED | | | IMPACTED AREAS. | | | 10. PROVIDE ONSITE CLEANOUTS NEAR PROPERTY LINE FOR | | | PROPOSED SANITARY LATERALS. | | | 11. COORDINATE WITH MARK HURLEY, FIELD CUSTOMER SERVICE | | | SUPERVISOR WITH CITY OF WPB PUBLIC UTILITIES, REGARDING | | | PLACEMENT OF BACKFLOW DEVICES AND WATER METERS. CONTACT | | | HIM AT 561-494-2262 OR [email protected] | | | 12. PROVIDE UTILITY EASEMENTS TO ALLOW ACCESS FOR CITY | | | PERSONNEL TO PROPOSED UTILITIES INCLUDING WATER METERS. | | | 13. PLEASE PROVIDE 10 FT. MIN. HORIZONTAL CLEARANCE | | | BETWEEN PROPOSED WATER AND SEWER LINES. | | | 14. PLEASE SHOW 10 IN. X 6 IN. TAP AT POINT OF SERVICE | | | (NO REDUCER). | | | 15. PLEASE SHOW SLOPE % ON ALL SANITARY LINES AND CALL | | | OUT MATERIAL. | | | 16. PLEASE PROVIDE INLET ELEVATIONS AT PROPOSED | | | MANHOLES. | | | 17. SPECIFY WATER MAIN IN RIGHT OF WAY AS 6 IN. DIP | | | MATERIAL. | | | 18. PLEASE SHOW VALVE SIZES AND LOCATIONS. LABEL CITY | | | POINT OF SERVICE. | | | 19. LABEL WATER LINES AS ?PRIVATE? WHERE APPLICABLE. | | | 20. FOR FORMAL ENGINEERING SUBMITTAL, PLEASE PROVIDE | | | ENLARGED VIEW ON PLANS OF PROPOSED LOCATION OF WATER | | | METER AND BACKFLOW PREVENTION. | | | 21. FOR FORMAL ENGINEERING SUBMITTAL, PLEASE CALLOUT | | | DOMESTIC BACKFLOW PREVENTER AS RPPA AND FIRE BACKFLOW | | | PREVENTER AS DCDA. | | | 22. FOR FORMAL ENGINEERING SUBMITTAL, PROVIDE PROFILES | | | OF WATER AND SEWER AND SHOW ANY CROSSINGS/CONFLICTS. | | | 23. FOR FORMAL ENGINEERING SUBMITTAL, WHEN SUBMITTING | | | APPROVED MATERIALS LIST, PLEASE PROVIDE MATERIAL/CUT | | | SHEETS FOR ALL PROPOSED BACKFLOW DEVICES SHOWING | | | SPECIFIC MODEL NUMBER AND SPECIFYING USC APPROVED | | | LEAD-FREE DESIGN. | | | 24. FOR FORMAL ENGINEERING SUBMITTAL PROVIDE SANITARY | | | ELEVATIONS AT MANHOLE TIE-IN. | | | 25. FOR FORMAL ENGINEERING SUBMITTAL, IF SANITARY LINES | | | ARE PROPOSED IN ROW PLEASE SHOW ADJACENT SANITARY | | | LATERAL LOCATIONS AND SHOW ADDRESSES OF ADJACENT | | | PARCELS. | | | 26. FOR FORMAL ENGINEERING SUBMITTAL, IF WATER LINES | | | ARE BEING REPLACED IN ROW, SHOW ADJACENT PARCEL | | | ADDRESSES. | | | 27. FOR FORMAL ENGINEERING SUBMITTAL, WHEN TRENCHING IN | | | IN CITY MAINTAINED ROADWAY AREAS ADD NOTE TO PROVIDE 50 | | | FT. PAVEMENT RESTORATION TRANSITION ON EACH SIDE OF | | | PROPOSED TRENCH PER CITY OF WPB STANDARD DETAIL GC-9. | | | 28. PLEASE RESPOND TO ALL COMMENTS IN WRITING. | | | | | | ----------------------------- | | | | | | PLEASE SEE ADDITIONAL COMMENTS FROM MARK HURLEY, | | | CUSTOMER SERVICE SUPERVISOR CITY OF WPB UTILITIES: | | | | | | FAMILY CHURCH OFF VILLAGE (SHEET C-150) | | | - PROP DDCV SHOULD BE LABELED WITH CORRECT WS SD # | | | A.) SIZE OF DDCV SHOULD BE LABELED | | | B.) NEED CITY POINT OF SERVICE VALVE ADDED IN THE 12? | | | U.E BEFORE/UPSTREAM OF DDCV. | | | C.) MATERIAL OF 6 IN. WATER MAIN NEEDS TO BE ADDED TO | | | LABEL (DIP, ETC..). | | | D.) EXISTING DDCV TO WEST WOULD HAVE TO BE UPGRADED TO | | | COMPLIANT ASSEMBLY IF NOT ALREADY -> FIELD CUSTOMER | | | SERVICE WOULD HAVE TO FIELD VERIFY. SIZE ALSO NEEDS | | | LABELING. | | | E.) WATER LINE FEEDING EXISTING FIRE HYDRANT NEEDS TO | | | BE LABELED WITH SIZE. | | | | | | - IS THERE A FIRE FDC ON FIRELINE? DO NOT SEE ONE ON | | | PLAN. DOES IT NEED ONE? (VERIFY WITH FIRE DEPT.) | | | | | | - NEED TO SHOW LOCATION AND SIZE OF EXISTING DOMESTIC | | | WATER METER & BACKFLOW PREVENTERS. | | | A.) PLAN DOES NOT MAKE SENSE- HOW WAS EXISTING 2 IN. | | | DOMESTIC SERVICE FED AT BUILDING- PLAN DOES NOT SHOW | | | ANY PIPING TO BE REMOVED ON UTILITY PLAN. | | | | | | - SHOW 6 IN. PVC FIRE PIPE TO THE EAST THAT IS BEING | | | REMOVED ON THE UTILITY PLAN. | | | | | | MR. HURLEY CAN BE REACHED AT 561-494-2262 OR | | | [email protected] | | | | | | FEEL FREE TO CONTACT US IF YOU HAVE ANY QUESTIONS OR | | | CONCERNS, THANKS. | | | | | | RICK ROSSANO, PROJECT COORDINATOR, ENGINEERING SERVICES | | | DEPARTMENT | | | DIRECT: (561) 494-1098 [email protected] | | | | | | | | | | | | | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
10-04-2019 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
10-04-2019 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
10-04-2019 |
Time |
16:29 |
Sent To |
|
|
| Notes |
| 2019-10-04 16:31:29 | THE FOLLOWING COMMENTS WERE SUBMITTED BY PETER LEDUC, | | | FIRE MARSHAL, BUREAU OF FIRE PREVENTION, WEST PALM | | | BEACH FIRE RESCUE. | | | | | | THE FIRE PREVENTION BUREAU HAS NO OBJECTIONS TO THE | | | PROPOSED REZONING. | | | | | | |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
4 |
Status |
P |
Date |
02-27-2020 |
|
|
Cont ID |
|
| Sent By |
rcaranci |
Date |
02-27-2020 |
Time |
16:59 |
Rev Time |
0.00 |
| Received By |
rcaranci |
Date |
02-27-2020 |
Time |
16:59 |
Sent To |
|
|
| Notes |
| 2020-02-27 17:00:07 | FROM: RAY CARANCI, LANDSCAPE PLANNER 561-822-1462 | | | PROJECT: FIRST BAPTIST CSPD | | | FEBRUARY 27, 2020 | | | MINOR SUBDIVISION Z19090011: NO COMMENTS. | | | FUTURE LAND USE MAP AMENDMENT Z19090012: NO COMMENTS. | | | REZONING TO CSPD Z19090013 | | | I HAVE REVIEWED THE ABOVE REFERENCED PETITION, AND | | | PROVIDE THE FOLLOWING COMMENTS: | | | | | | 1. SATISFIED. PROVIDE THE AMOUNT OF REQUIRED AND | | | PROVIDED OPEN SPACE AND LANDSCAPE AREA ON THE LANDSCAPE | | | PLAN MEETING THE REQUIREMENTS OF 50 PERCENT FOR CSPD | | | ZONING PER SECTION 94-203. | | | | | | 2. SATISFIED. SHOW THE CALCULATIONS FOR MINIMUM SHADE | | | TREE AND FLOWERING TREE REQUIREMENTS PER SECTION | | | 94-443(C)(2)B. BASED ON THE 50 PERCENT REQUIRED FOR | | | CSPD ZONING. | | | CALCULATIONS ARE TO BE ROUNDED UP FOR EACH REQUIREMENT, | | | SO 81 SHADE TREES REQUIRED, 21 FLOWERING TREES REQUIRED | | | FOR A TOTAL OF 102. CHART INDICATES 125 TREES PROVIDED, | | | AND PLANT LIST ONLY SHOWS 111. | | | | | | | | | 3. SATISFIED. SHOW ALL CALCULATIONS FOR THE REQUIRED | | | TREES FOR BUFFER SEGMENTS ON A PERIMETER BUFFER | | | REQUIREMENT CHART INCLUDING LINEAR FOOTAGE OF ALL | | | PROPERTY LINE SEGMENTS. | | | BUFFER SEGMENTS NEED TO BE DIVIDED AND SHOWN AS SOUTH | | | (VILLAGE BLVD.), WEST (ADJACENT TO CANAL), NORTH (ALL | | | SEGMENTS), AND EAST (PARKING LOT SIDE). SHOW TOTAL | | | BUFFER LENGTH AND DIVIDE BY 30, ROUND UP TO THE NEXT | | | FULL TREE AND SHOW THE REQUIRED NUMBER OF TREES, THE | | | NUMBER PROVIDED, AND THE NUMBER REQUESTED TO BE WAIVED | | | FOR THAT SEGMENT. | | | | | | 4. SATISFIED. PROVIDE CALCULATIONS FOR THE BUFFER ALONG | | | VILLAGE BOULEVARD WITH ACCESS DRIVEWAYS TO SHOW THEY DO | | | NOT EXCEED 25% INTERRUPTION FOR VEHICULAR ACCESS AS | | | REQUIRED BY SECTION 94-443(B)(2). | | | | | | 5. SATISFIED. PROVIDE THE REQUIRED 5 FOOT LANDSCAPE | | | BUFFER PLANTINGS ALONG ALL PROPERTY LINES WITH THE | | | REQUIRED TREES OR NUMBER OF SUBSTITUTE PALMS PER | | | CURRENT CODE REQUIREMENTS OF SECTION 94-443(D). | | | INDICATE THE LANDSCAPE BUFFER LOCATIONS ON THE SITE | | | PLAN AND LANDSCAPE PLAN. | | | SEE COMMENT #3 ABOVE. PLACE A DOTTED LINE ON PLANS 5 | | | FEET FROM PROPERTY LINE AND LABEL AS LANDSCAPE BUFFER. | | | | | | 6. SATISFIED. ALL MISSING OR DEAD SHRUBS MUST BE | | | REPLACED IN ALL BUFFER HEDGES AS REQUIRED. ADD A NOTE | | | TO THE PLAN. | | | | | | 7. SATISFIED. MODIFY THE PLANT LIST TO ADD COLUMNS FOR | | | NATIVE PLANT AND DROUGHT TOLERANCE LEVELS TO PROVIDE | | | EASIER REFERENCE. | | | | | | 8. SATISFIED. ADD RELOCATED TREES TO THE PLANT LIST AND | | | COUNT THEM TOWARD THE REQUIRED TREES. | | | PROVIDE THE EXACT BREAKDOWN OF PALMS AND TREES ON THE | | | PLANT LIST. | | | SPLIT OAKS AND SABALS INTO 2 LINES. | | | | | | 9. SATISFIED. CORRECT THE REQUIRED FOUNDATION PLANTING | | | TO 30 PERCENT REQUIRED PER SECTION 94-443(E)(1). | | | | | | 10. SATISFIED. SHOW ALL REQUIRED CURBS ADJACENT TO | | | LANDSCAPE AREAS PER SECTION 94-443 (C)(5). THERE APPEAR | | | TO BE AREAS THAT ARE NOT CURBED. LANDSCAPE DIVIDER | | | STRIPS CAN HAVE CURBS INSTEAD OF WHEEL STOPS TO | | | INCREASE THE LANDSCAPE AREA FOR THE TREES. IF DRAINAGE | | | IS A CONCERN, THEY CAN BE DESIGNED TO ROUTE WATER INTO | | | THE LANDSCAPE AREAS. | | | THERE ARE AREAS WITH EXISTING TREES THAT APPEAR TO HAVE | | | THE PAVEMENT AND CURBS TOO CLOSE TO THE BASE OF TREES. | | | | | | 11. SATISFIED. PROVIDE AN EXHIBIT SHOWING THE PARKING | | | AREA SURFACE CALCULATIONS, PARKING SPACE AREAS AND | | | LANDSCAPE AREAS PROVIDED TO DEMONSTRATE COMPLIANCE WITH | | | SECTIONS 94-443 (C)(3) AND (4). | | | NEW PAVED AREAS NEED TO MEET CODE REQUIREMENTS, SEE | | | FIGURE XIV-1 LANDSCAPE AREAS FOR PARKING LOTS IN | | | SECTION 94-443(C)(3) FOR THE AREAS THAT QUALIFY AS | | | INTERIOR LANDSCAPING FOR VEHICULAR USE AREA. | | | PROVIDE AS A LARGER 1:20 SCALE PLAN FOR REVIEW. | | | | | | 12. SATISFIED. ALL NEW OR ALTERED ROWS OF PARKING MUST | | | HAVE TERMINAL LANDSCAPE ISLANDS MEETING THE | | | REQUIREMENTS OF SECTION 94-443(C)(3)A. FOR LANDSCAPE | | | AREA WIDTH OF 8 FEET INSIDE CURB FOR THE FULL LENGTH OF | | | THE PARKING SPACE. THE REQUIRED TERMINAL ISLANDS SHADE | | | TREES ARE MISSING WHERE THE EXISTING PARKING AREA IS | | | BEING ABBREVIATED, AND SOME ARE NOT CLEAR TO IDENTIFY | | | THE QUALIFYING TREE. REVISE PLAN TO MEET REQUIREMENTS. | | | REQUEST A WAIVER IF REQUIREMENTS CANNOT BE MET AND | | | PROVIDE JUSTIFICATION. | | | THERE IS ONE TERMINAL ISLAND LACKING THE REQUIRED TREE. | | | SMALL SPACE CAN BE MET WITH PALMS. | | | | | | 13. SATISFIED. UPDATE THE FLORIDA FRIENDLY LANDSCAPE | | | CHART TO THE CURRENT CODE AND PROVIDE THE MINIMUM 50 | | | POINTS PER SECTION 94-442(G) BASED ON THE PLANT LIST | | | AND ITEMS THAT QUALIFY. SOME WORDING AND PERCENTAGES | | | ARE NOT CORRECT. | | | | | | 14. SATISFIED. PROVIDE LOCATIONS OF LIGHTING ON THE | | | LANDSCAPE PLAN TO AVOID CONFLICTS WITH LANDSCAPING. | | | LIGHTING LOCATIONS SHOWN MAY CONFLICT WITH EXISTING | | | TREE CANOPY, CONSIDERATION SHOULD BE MADE TO ADJUST | | | POLE HEIGHTS TO BELOW THE TREE CANOPY TO BE MORE | | | EFFICIENT WITH LIGHTING AND AVOID ADDING MAINTENANCE | | | COSTS FOR TREE PRUNING. | | | | | | 15. SATISFIED. THERE APPEAR TO BE CONFLICTS IN MANY | | | LOCATIONS BETWEEN TREES AND DRAINAGE LINES, WATER AND | | | SEWER LINES ON THE LANDSCAPE PLAN. ADJUST LOCATIONS OF | | | TREES OR UTILITY LINES TO RESOLVE CONFLICTS WITH | | | LANDSCAPING. | | | THERE ARE STILL SOME CONFLICTS WHERE WATER LINES ARE IN | | | DIRECT CONFLICT WITH NEW TREE PLACEMENT AND EXISTING | | | TREES. | | | THERE IS ONE NEW OAK TREE TO THE RIGHT OF THE FRONT | | | ENTRANCE OF THE BUILDING THAT IS PLACED ON TOP OF FIRE | | | LINE. | | | . | | | 16. SATISFIED. PROVIDE LOCATIONS AND SCREENING FOR ALL | | | ABOVE GROUND UTILITY VALVES, BACKFLOW PREVENTERS, A/C | | | UNITS, AND FPL TRANSFORMERS. | | | | | | 17. SATISFIED. SHOW LOCATIONS OF ANY ROOT BARRIERS | | | REQUIRED TO PROTECT UTILITY LINES AND PROVIDE A ROOT | | | BARRIER DETAIL. | | | | | | 18. PARTIALLY SATISFIED. SHOW COMPLIANCE WITH SECTION | | | 94-445 L. PLANT SPECIES. A MINIMUM OF 60 PERCENT OF | | | PLANT MATERIAL ADDED SHALL BE FLORIDA NATIVE OR DROUGHT | | | TOLERANT SPECIES SELECTED FROM THE CITY LIST OR THE | | | LIST OF SPECIES IN THE MOST RECENT EDITION OF SOUTH | | | FLORIDA WATER MANAGEMENT DISTRICT WATERWISE SOUTH | | | FLORIDA LANDSCAPES. | | | PROVIDE THE ACTUAL PERCENTAGE. | | | ADDITIONAL COMMENTS 12/5/19: | | | 19. SATISFIED. CORRECT THE TREE DISPOSITION PLAN TO | | | SHOW TREE #216 FINAL LOCATION, AS TREE #53 IS LABELED | | | IN TWO LOCATIONS. | | | | | | CONDITIONS OF APPROVAL | | | 1. PRIOR TO THE REMOVAL OR RELOCATION OF ANY TREES ON | | | THE PROPERTY, A TREE ALTERATION PERMIT SHALL BE | | | SUBMITTED, REVIEWED AND APPROVED BY THE DEVELOPMENT | | | SERVICES DEPARTMENT, PLANNING DIVISION. | | | |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
3 |
Status |
F |
Date |
02-03-2020 |
|
|
Cont ID |
|
| Sent By |
rcaranci |
Date |
02-03-2020 |
Time |
15:47 |
Rev Time |
0.00 |
| Received By |
rcaranci |
Date |
02-03-2020 |
Time |
15:47 |
Sent To |
|
|
| Notes |
| 2020-02-03 15:47:32 | FROM: RAY CARANCI, LANDSCAPE PLANNER 561-822-1462 | | | PROJECT: FIRST BAPTIST CSPD | | | FEBRUARY 3, 2020 | | | MINOR SUBDIVISION Z19090011: NO COMMENTS. | | | FUTURE LAND USE MAP AMENDMENT Z19090012: NO COMMENTS. | | | REZONING TO CSPD Z19090013 | | | I HAVE REVIEWED THE ABOVE REFERENCED PETITION, AND | | | PROVIDE THE FOLLOWING COMMENTS: | | | | | | 1. SATISFIED. PROVIDE THE AMOUNT OF REQUIRED AND | | | PROVIDED OPEN SPACE AND LANDSCAPE AREA ON THE LANDSCAPE | | | PLAN MEETING THE REQUIREMENTS OF 50 PERCENT FOR CSPD | | | ZONING PER SECTION 94-203. | | | | | | 2. SATISFIED. SHOW THE CALCULATIONS FOR MINIMUM SHADE | | | TREE AND FLOWERING TREE REQUIREMENTS PER SECTION | | | 94-443(C)(2)B. BASED ON THE 50 PERCENT REQUIRED FOR | | | CSPD ZONING. | | | CALCULATIONS ARE TO BE ROUNDED UP FOR EACH REQUIREMENT, | | | SO 81 SHADE TREES REQUIRED, 21 FLOWERING TREES REQUIRED | | | FOR A TOTAL OF 102. CHART INDICATES 125 TREES PROVIDED, | | | AND PLANT LIST ONLY SHOWS 111. | | | | | | | | | 3. SATISFIED. SHOW ALL CALCULATIONS FOR THE REQUIRED | | | TREES FOR BUFFER SEGMENTS ON A PERIMETER BUFFER | | | REQUIREMENT CHART INCLUDING LINEAR FOOTAGE OF ALL | | | PROPERTY LINE SEGMENTS. | | | BUFFER SEGMENTS NEED TO BE DIVIDED AND SHOWN AS SOUTH | | | (VILLAGE BLVD.), WEST (ADJACENT TO CANAL), NORTH (ALL | | | SEGMENTS), AND EAST (PARKING LOT SIDE). SHOW TOTAL | | | BUFFER LENGTH AND DIVIDE BY 30, ROUND UP TO THE NEXT | | | FULL TREE AND SHOW THE REQUIRED NUMBER OF TREES, THE | | | NUMBER PROVIDED, AND THE NUMBER REQUESTED TO BE WAIVED | | | FOR THAT SEGMENT. | | | | | | 4. SATISFIED. PROVIDE CALCULATIONS FOR THE BUFFER ALONG | | | VILLAGE BOULEVARD WITH ACCESS DRIVEWAYS TO SHOW THEY DO | | | NOT EXCEED 25% INTERRUPTION FOR VEHICULAR ACCESS AS | | | REQUIRED BY SECTION 94-443(B)(2). | | | | | | 5. SATISFIED. PROVIDE THE REQUIRED 5 FOOT LANDSCAPE | | | BUFFER PLANTINGS ALONG ALL PROPERTY LINES WITH THE | | | REQUIRED TREES OR NUMBER OF SUBSTITUTE PALMS PER | | | CURRENT CODE REQUIREMENTS OF SECTION 94-443(D). | | | INDICATE THE LANDSCAPE BUFFER LOCATIONS ON THE SITE | | | PLAN AND LANDSCAPE PLAN. | | | SEE COMMENT #3 ABOVE. PLACE A DOTTED LINE ON PLANS 5 | | | FEET FROM PROPERTY LINE AND LABEL AS LANDSCAPE BUFFER. | | | | | | 6. SATISFIED. ALL MISSING OR DEAD SHRUBS MUST BE | | | REPLACED IN ALL BUFFER HEDGES AS REQUIRED. ADD A NOTE | | | TO THE PLAN. | | | | | | 7. SATISFIED. MODIFY THE PLANT LIST TO ADD COLUMNS FOR | | | NATIVE PLANT AND DROUGHT TOLERANCE LEVELS TO PROVIDE | | | EASIER REFERENCE. | | | | | | 8. PARTIALLY SATISFIED. ADD RELOCATED TREES TO THE | | | PLANT LIST AND COUNT THEM TOWARD THE REQUIRED TREES. | | | PROVIDE THE EXACT BREAKDOWN OF PALMS AND TREES ON THE | | | PLANT LIST. | | | SPLIT OAKS AND SABALS INTO 2 LINES. | | | | | | 9. SATISFIED. CORRECT THE REQUIRED FOUNDATION PLANTING | | | TO 30 PERCENT REQUIRED PER SECTION 94-443(E)(1). | | | | | | 10. SATISFIED. SHOW ALL REQUIRED CURBS ADJACENT TO | | | LANDSCAPE AREAS PER SECTION 94-443 (C)(5). THERE APPEAR | | | TO BE AREAS THAT ARE NOT CURBED. LANDSCAPE DIVIDER | | | STRIPS CAN HAVE CURBS INSTEAD OF WHEEL STOPS TO | | | INCREASE THE LANDSCAPE AREA FOR THE TREES. IF DRAINAGE | | | IS A CONCERN, THEY CAN BE DESIGNED TO ROUTE WATER INTO | | | THE LANDSCAPE AREAS. | | | THERE ARE AREAS WITH EXISTING TREES THAT APPEAR TO HAVE | | | THE PAVEMENT AND CURBS TOO CLOSE TO THE BASE OF TREES. | | | | | | 11. SATISFIED. PROVIDE AN EXHIBIT SHOWING THE PARKING | | | AREA SURFACE CALCULATIONS, PARKING SPACE AREAS AND | | | LANDSCAPE AREAS PROVIDED TO DEMONSTRATE COMPLIANCE WITH | | | SECTIONS 94-443 (C)(3) AND (4). | | | NEW PAVED AREAS NEED TO MEET CODE REQUIREMENTS, SEE | | | FIGURE XIV-1 LANDSCAPE AREAS FOR PARKING LOTS IN | | | SECTION 94-443(C)(3) FOR THE AREAS THAT QUALIFY AS | | | INTERIOR LANDSCAPING FOR VEHICULAR USE AREA. | | | PROVIDE AS A LARGER 1:20 SCALE PLAN FOR REVIEW. | | | | | | 12. PARTIALLY SATISFIED. ALL NEW OR ALTERED ROWS OF | | | PARKING MUST HAVE TERMINAL LANDSCAPE ISLANDS MEETING | | | THE REQUIREMENTS OF SECTION 94-443(C)(3)A. FOR | | | LANDSCAPE AREA WIDTH OF 8 FEET INSIDE CURB FOR THE FULL | | | LENGTH OF THE PARKING SPACE. THE REQUIRED TERMINAL | | | ISLANDS SHADE TREES ARE MISSING WHERE THE EXISTING | | | PARKING AREA IS BEING ABBREVIATED, AND SOME ARE NOT | | | CLEAR TO IDENTIFY THE QUALIFYING TREE. REVISE PLAN TO | | | MEET REQUIREMENTS. | | | REQUEST A WAIVER IF REQUIREMENTS CANNOT BE MET AND | | | PROVIDE JUSTIFICATION. | | | THERE IS ONE TERMINAL ISLAND LACKING THE REQUIRED TREE. | | | SMALL SPACE CAN BE MET WITH PALMS. | | | | | | 13. SATISFIED. UPDATE THE FLORIDA FRIENDLY LANDSCAPE | | | CHART TO THE CURRENT CODE AND PROVIDE THE MINIMUM 50 | | | POINTS PER SECTION 94-442(G) BASED ON THE PLANT LIST | | | AND ITEMS THAT QUALIFY. SOME WORDING AND PERCENTAGES | | | ARE NOT CORRECT. | | | | | | 14. SATISFIED. PROVIDE LOCATIONS OF LIGHTING ON THE | | | LANDSCAPE PLAN TO AVOID CONFLICTS WITH LANDSCAPING. | | | LIGHTING LOCATIONS SHOWN MAY CONFLICT WITH EXISTING | | | TREE CANOPY, CONSIDERATION SHOULD BE MADE TO ADJUST | | | POLE HEIGHTS TO BELOW THE TREE CANOPY TO BE MORE | | | EFFICIENT WITH LIGHTING AND AVOID ADDING MAINTENANCE | | | COSTS FOR TREE PRUNING. | | | | | | 15. PARTIALLY SATISFIED. THERE APPEAR TO BE CONFLICTS | | | IN MANY LOCATIONS BETWEEN TREES AND DRAINAGE LINES, | | | WATER AND SEWER LINES ON THE LANDSCAPE PLAN. ADJUST | | | LOCATIONS OF TREES OR UTILITY LINES TO RESOLVE | | | CONFLICTS WITH LANDSCAPING. | | | THERE ARE STILL SOME CONFLICTS WHERE WATER LINES ARE IN | | | DIRECT CONFLICT WITH NEW TREE PLACEMENT AND EXISTING | | | TREES. | | | THERE IS ONE NEW OAK TREE TO THE RIGHT OF THE FRONT | | | ENTRANCE OF THE BUILDING THAT IS PLACED ON TOP OF FIRE | | | LINE. | | | . | | | 16. SATISFIED. PROVIDE LOCATIONS AND SCREENING FOR ALL | | | ABOVE GROUND UTILITY VALVES, BACKFLOW PREVENTERS, A/C | | | UNITS, AND FPL TRANSFORMERS. | | | | | | 17. SATISFIED. SHOW LOCATIONS OF ANY ROOT BARRIERS | | | REQUIRED TO PROTECT UTILITY LINES AND PROVIDE A ROOT | | | BARRIER DETAIL. | | | | | | 18. PARTIALLY SATISFIED. SHOW COMPLIANCE WITH SECTION | | | 94-445 L. PLANT SPECIES. A MINIMUM OF 60 PERCENT OF | | | PLANT MATERIAL ADDED SHALL BE FLORIDA NATIVE OR DROUGHT | | | TOLERANT SPECIES SELECTED FROM THE CITY LIST OR THE | | | LIST OF SPECIES IN THE MOST RECENT EDITION OF SOUTH | | | FLORIDA WATER MANAGEMENT DISTRICT WATERWISE SOUTH | | | FLORIDA LANDSCAPES. | | | PROVIDE THE ACTUAL PERCENTAGE. | | | ADDITIONAL COMMENTS 12/5/19: | | | 19. SATISFIED. CORRECT THE TREE DISPOSITION PLAN TO | | | SHOW TREE #216 FINAL LOCATION, AS TREE #53 IS LABELED | | | IN TWO LOCATIONS. | | | | | | CONDITIONS OF APPROVAL | | | 1. PRIOR TO THE REMOVAL OR RELOCATION OF ANY TREES ON | | | THE PROPERTY, A TREE ALTERATION PERMIT SHALL BE | | | SUBMITTED, REVIEWED AND APPROVED BY THE DEVELOPMENT | | | SERVICES DEPARTMENT, PLANNING DIVISION. | | | |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
2 |
Status |
F |
Date |
12-06-2019 |
|
|
Cont ID |
|
| Sent By |
rcaranci |
Date |
12-06-2019 |
Time |
17:06 |
Rev Time |
0.00 |
| Received By |
rcaranci |
Date |
12-06-2019 |
Time |
17:06 |
Sent To |
|
|
| Notes |
| 2019-12-06 17:07:21 | FROM: RAY CARANCI, LANDSCAPE PLANNER 561-822-1462 | | | PROJECT: FIRST BAPTIST CSPD | | | DECEMBER 6, 2019 | | | MINOR SUBDIVISION Z19090011: NO COMMENTS. | | | FUTURE LAND USE MAP AMENDMENT Z19090012: NO COMMENTS. | | | REZONING TO CSPD Z19090013 | | | I HAVE REVIEWED THE ABOVE REFERENCED PETITION, AND | | | PROVIDE THE FOLLOWING COMMENTS: | | | | | | 1. SATISFIED. PROVIDE THE AMOUNT OF REQUIRED AND | | | PROVIDED OPEN SPACE AND LANDSCAPE AREA ON THE LANDSCAPE | | | PLAN MEETING THE REQUIREMENTS OF 50 PERCENT FOR CSPD | | | ZONING PER SECTION 94-203. | | | | | | 2. PARTIALLY SATISFIED. SHOW THE CALCULATIONS FOR | | | MINIMUM SHADE TREE AND FLOWERING TREE REQUIREMENTS PER | | | SECTION 94-443(C)(2)B. BASED ON THE 50 PERCENT REQUIRED | | | FOR CSPD ZONING. | | | CALCULATIONS ARE TO BE ROUNDED UP FOR EACH REQUIREMENT, | | | SO 81 SHADE TREES REQUIRED, 21 FLOWERING TREES REQUIRED | | | FOR A TOTAL OF 102. CHART INDICATES 125 TREES PROVIDED, | | | AND PLANT LIST ONLY SHOWS 111. | | | | | | | | | 3. PARTIALLY SATISFIED. SHOW ALL CALCULATIONS FOR THE | | | REQUIRED TREES FOR BUFFER SEGMENTS ON A PERIMETER | | | BUFFER REQUIREMENT CHART INCLUDING LINEAR FOOTAGE OF | | | ALL PROPERTY LINE SEGMENTS. | | | BUFFER SEGMENTS NEED TO BE DIVIDED AND SHOWN AS SOUTH | | | (VILLAGE BLVD.), WEST (ADJACENT TO CANAL), NORTH (ALL | | | SEGMENTS), AND EAST (PARKING LOT SIDE). SHOW TOTAL | | | BUFFER LENGTH AND DIVIDE BY 30, ROUND UP TO THE NEXT | | | FULL TREE AND SHOW THE REQUIRED NUMBER OF TREES, THE | | | NUMBER PROVIDED, AND THE NUMBER REQUESTED TO BE WAIVED | | | FOR THAT SEGMENT. | | | | | | 4. SATISFIED. PROVIDE CALCULATIONS FOR THE BUFFER ALONG | | | VILLAGE BOULEVARD WITH ACCESS DRIVEWAYS TO SHOW THEY DO | | | NOT EXCEED 25% INTERRUPTION FOR VEHICULAR ACCESS AS | | | REQUIRED BY SECTION 94-443(B)(2). | | | | | | 5. PARTIALLY SATISFIED. PROVIDE THE REQUIRED 5 FOOT | | | LANDSCAPE BUFFER PLANTINGS ALONG ALL PROPERTY LINES | | | WITH THE REQUIRED TREES OR NUMBER OF SUBSTITUTE PALMS | | | PER CURRENT CODE REQUIREMENTS OF SECTION 94-443(D). | | | INDICATE THE LANDSCAPE BUFFER LOCATIONS ON THE SITE | | | PLAN AND LANDSCAPE PLAN. | | | SEE COMMENT #3 ABOVE. PLACE A DOTTED LINE ON PLANS 5 | | | FEET FROM PROPERTY LINE AND LABEL AS LANDSCAPE BUFFER. | | | | | | 6. SATISFIED. ALL MISSING OR DEAD SHRUBS MUST BE | | | REPLACED IN ALL BUFFER HEDGES AS REQUIRED. ADD A NOTE | | | TO THE PLAN. | | | | | | 7. SATISFIED. MODIFY THE PLANT LIST TO ADD COLUMNS FOR | | | NATIVE PLANT AND DROUGHT TOLERANCE LEVELS TO PROVIDE | | | EASIER REFERENCE. | | | | | | 8. PARTIALLY SATISFIED. ADD RELOCATED TREES TO THE | | | PLANT LIST AND COUNT THEM TOWARD THE REQUIRED TREES. | | | PROVIDE THE EXACT BREAKDOWN OF PALMS AND TREES ON THE | | | PLANT LIST. | | | | | | 9. SATISFIED. CORRECT THE REQUIRED FOUNDATION PLANTING | | | TO 30 PERCENT REQUIRED PER SECTION 94-443(E)(1). | | | | | | 10. PARTIALLY SATISFIED. SHOW ALL REQUIRED CURBS | | | ADJACENT TO LANDSCAPE AREAS PER SECTION 94-443 (C)(5). | | | THERE APPEAR TO BE AREAS THAT ARE NOT CURBED. LANDSCAPE | | | DIVIDER STRIPS CAN HAVE CURBS INSTEAD OF WHEEL STOPS TO | | | INCREASE THE LANDSCAPE AREA FOR THE TREES. IF DRAINAGE | | | IS A CONCERN, THEY CAN BE DESIGNED TO ROUTE WATER INTO | | | THE LANDSCAPE AREAS. | | | THERE ARE AREAS WITH EXISTING TREES THAT APPEAR TO HAVE | | | THE PAVEMENT AND CURBS TOO CLOSE TO THE BASE OF TREES. | | | | | | 11. PARTIALLY SATISFIED. PROVIDE AN EXHIBIT SHOWING THE | | | PARKING AREA SURFACE CALCULATIONS, PARKING SPACE AREAS | | | AND LANDSCAPE AREAS PROVIDED TO DEMONSTRATE COMPLIANCE | | | WITH SECTIONS 94-443 (C)(3) AND (4). | | | NEW PAVED AREAS NEED TO MEET CODE REQUIREMENTS, SEE | | | FIGURE XIV-1 LANDSCAPE AREAS FOR PARKING LOTS IN | | | SECTION 94-443(C)(3) FOR THE AREAS THAT QUALIFY AS | | | INTERIOR LANDSCAPING FOR VEHICULAR USE AREA. | | | PROVIDE AS A LARGER 1:20 SCALE PLAN FOR REVIEW. | | | | | | 12. NOT SATISFIED. ALL NEW OR ALTERED ROWS OF PARKING | | | MUST HAVE TERMINAL LANDSCAPE ISLANDS MEETING THE | | | REQUIREMENTS OF SECTION 94-443(C)(3)A. FOR LANDSCAPE | | | AREA WIDTH OF 8 FEET INSIDE CURB FOR THE FULL LENGTH OF | | | THE PARKING SPACE. THE REQUIRED TERMINAL ISLANDS SHADE | | | TREES ARE MISSING WHERE THE EXISTING PARKING AREA IS | | | BEING ABBREVIATED, AND SOME ARE NOT CLEAR TO IDENTIFY | | | THE QUALIFYING TREE. REVISE PLAN TO MEET REQUIREMENTS. | | | REQUEST A WAIVER IF REQUIREMENTS CANNOT BE MET AND | | | PROVIDE JUSTIFICATION. | | | | | | 13. SATISFIED. UPDATE THE FLORIDA FRIENDLY LANDSCAPE | | | CHART TO THE CURRENT CODE AND PROVIDE THE MINIMUM 50 | | | POINTS PER SECTION 94-442(G) BASED ON THE PLANT LIST | | | AND ITEMS THAT QUALIFY. SOME WORDING AND PERCENTAGES | | | ARE NOT CORRECT. | | | | | | 14. PARTIALLY SATISFIED. PROVIDE LOCATIONS OF LIGHTING | | | ON THE LANDSCAPE PLAN TO AVOID CONFLICTS WITH | | | LANDSCAPING. | | | LIGHTING LOCATIONS SHOWN MAY CONFLICT WITH EXISTING | | | TREE CANOPY, CONSIDERATION SHOULD BE MADE TO ADJUST | | | POLE HEIGHTS TO BELOW THE TREE CANOPY TO BE MORE | | | EFFICIENT WITH LIGHTING AND AVOID ADDING MAINTENANCE | | | COSTS FOR TREE PRUNING. | | | | | | 15. PARTIALLY SATISFIED. THERE APPEAR TO BE CONFLICTS | | | IN MANY LOCATIONS BETWEEN TREES AND DRAINAGE LINES, | | | WATER AND SEWER LINES ON THE LANDSCAPE PLAN. ADJUST | | | LOCATIONS OF TREES OR UTILITY LINES TO RESOLVE | | | CONFLICTS WITH LANDSCAPING. | | | THERE ARE STILL SOME CONFLICTS WHERE WATER LINES ARE IN | | | DIRECT CONFLICT WITH NEW TREE PLACEMENT AND EXISTING | | | TREES. | | | . | | | 16. SATISFIED. PROVIDE LOCATIONS AND SCREENING FOR ALL | | | ABOVE GROUND UTILITY VALVES, BACKFLOW PREVENTERS, A/C | | | UNITS, AND FPL TRANSFORMERS. | | | | | | 17. PARTIALLY SATISFIED. SHOW LOCATIONS OF ANY ROOT | | | BARRIERS REQUIRED TO PROTECT UTILITY LINES AND PROVIDE | | | A ROOT BARRIER DETAIL. | | | | | | 18. PARTIALLY SATISFIED. SHOW COMPLIANCE WITH SECTION | | | 94-445 L. PLANT SPECIES. A MINIMUM OF 60 PERCENT OF | | | PLANT MATERIAL ADDED SHALL BE FLORIDA NATIVE OR DROUGHT | | | TOLERANT SPECIES SELECTED FROM THE CITY LIST OR THE | | | LIST OF SPECIES IN THE MOST RECENT EDITION OF SOUTH | | | FLORIDA WATER MANAGEMENT DISTRICT WATERWISE SOUTH | | | FLORIDA LANDSCAPES. | | | ADDITIONAL COMMENTS 12/5/19: | | | 19. CORRECT THE TREE DISPOSITION PLAN TO SHOW TREE #216 | | | FINAL LOCATION, AS TREE #53 IS LABELED IN TWO | | | LOCATIONS. | | | | | | CONDITIONS OF APPROVAL | | | 1. PRIOR TO THE REMOVAL OR RELOCATION OF ANY TREES ON | | | THE PROPERTY, A TREE ALTERATION PERMIT SHALL BE | | | SUBMITTED, REVIEWED AND APPROVED BY THE DEVELOPMENT | | | SERVICES DEPARTMENT, PLANNING DIVISION. | | | |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
1 |
Status |
F |
Date |
10-09-2019 |
|
|
Cont ID |
|
| Sent By |
rcaranci |
Date |
10-09-2019 |
Time |
16:17 |
Rev Time |
0.00 |
| Received By |
rcaranci |
Date |
10-09-2019 |
Time |
16:17 |
Sent To |
|
|
| Notes |
| 2019-10-09 16:17:39 | FROM: RAY CARANCI, LANDSCAPE PLANNER 561-822-1462 | | | PROJECT: FIRST BAPTIST CSPD | | | OCTOBER 9, 2019 | | | MINOR SUBDIVISION Z19090011: NO COMMENTS. | | | FUTURE LAND USE MAP AMENDMENT Z19090012: NO COMMENTS. | | | REZONING TO CSPD Z19090013 | | | I HAVE REVIEWED THE ABOVE REFERENCED PETITION, AND | | | PROVIDE THE FOLLOWING COMMENTS: | | | | | | 1. PROVIDE THE AMOUNT OF REQUIRED AND PROVIDED OPEN | | | SPACE AND LANDSCAPE AREA ON THE LANDSCAPE PLAN MEETING | | | THE REQUIREMENTS OF 50 PERCENT FOR CSPD ZONING PER | | | SECTION 94-203. | | | | | | 2. SHOW THE CALCULATIONS FOR MINIMUM SHADE TREE AND | | | FLOWERING TREE REQUIREMENTS PER SECTION 94-443(C)(2)B. | | | BASED ON THE 50 PERCENT REQUIRED FOR CSPD ZONING. | | | | | | | | | 3. SHOW ALL CALCULATIONS FOR THE REQUIRED TREES FOR | | | BUFFER SEGMENTS ON A PERIMETER BUFFER REQUIREMENT CHART | | | INCLUDING LINEAR FOOTAGE OF ALL PROPERTY LINE SEGMENTS. | | | | | | 4. PROVIDE CALCULATIONS FOR THE BUFFER ALONG VILLAGE | | | BOULEVARD WITH ACCESS DRIVEWAYS TO SHOW THEY DO NOT | | | EXCEED 25% INTERRUPTION FOR VEHICULAR ACCESS AS | | | REQUIRED BY SECTION 94-443(B)(2). | | | | | | 5. PROVIDE THE REQUIRED 5 FOOT LANDSCAPE BUFFER | | | PLANTINGS ALONG ALL PROPERTY LINES WITH THE REQUIRED | | | TREES OR NUMBER OF SUBSTITUTE PALMS PER CURRENT CODE | | | REQUIREMENTS OF SECTION 94-443(D). INDICATE THE | | | LANDSCAPE BUFFER LOCATIONS ON THE SITE PLAN AND | | | LANDSCAPE PLAN. | | | | | | 6. ALL MISSING OR DEAD SHRUBS MUST BE REPLACED IN ALL | | | BUFFER HEDGES AS REQUIRED. ADD A NOTE TO THE PLAN. | | | | | | 7. MODIFY THE PLANT LIST TO ADD COLUMNS FOR NATIVE | | | PLANT AND DROUGHT TOLERANCE LEVELS TO PROVIDE EASIER | | | REFERENCE. | | | | | | 8. ADD RELOCATED TREES TO THE PLANT LIST AND COUNT THEM | | | TOWARD THE REQUIRED TREES. | | | | | | 9. CORRECT THE REQUIRED FOUNDATION PLANTING TO 30 | | | PERCENT REQUIRED PER SECTION 94-443(E)(1). | | | | | | 10. SHOW ALL REQUIRED CURBS ADJACENT TO LANDSCAPE AREAS | | | PER SECTION 94-443 (C)(5). THERE APPEAR TO BE AREAS | | | THAT ARE NOT CURBED. LANDSCAPE DIVIDER STRIPS CAN HAVE | | | CURBS INSTEAD OF WHEEL STOPS TO INCREASE THE LANDSCAPE | | | AREA FOR THE TREES. IF DRAINAGE IS A CONCERN, THEY CAN | | | BE DESIGNED TO ROUTE WATER INTO THE LANDSCAPE AREAS. | | | | | | 11. PROVIDE AN EXHIBIT SHOWING THE PARKING AREA SURFACE | | | CALCULATIONS, PARKING SPACE AREAS AND LANDSCAPE AREAS | | | PROVIDED TO DEMONSTRATE COMPLIANCE WITH SECTIONS 94-443 | | | (C)(3) AND (4). | | | NEW PAVED AREAS NEED TO MEET CODE REQUIREMENTS, SEE | | | FIGURE XIV-1 LANDSCAPE AREAS FOR PARKING LOTS IN | | | SECTION 94-443(C)(3) FOR THE AREAS THAT QUALIFY AS | | | INTERIOR LANDSCAPING FOR VEHICULAR USE AREA. | | | | | | 12. ALL NEW OR ALTERED ROWS OF PARKING MUST HAVE | | | TERMINAL LANDSCAPE ISLANDS MEETING THE REQUIREMENTS OF | | | SECTION 94-443(C)(3)A. FOR LANDSCAPE AREA WIDTH OF 8 | | | FEET INSIDE CURB FOR THE FULL LENGTH OF THE PARKING | | | SPACE. THE REQUIRED TERMINAL ISLANDS SHADE TREES ARE | | | MISSING WHERE THE EXISTING PARKING AREA IS BEING | | | ABBREVIATED, AND SOME ARE NOT CLEAR TO IDENTIFY THE | | | QUALIFYING TREE. REVISE PLAN TO MEET REQUIREMENTS. | | | | | | 13. UPDATE THE FLORIDA FRIENDLY LANDSCAPE CHART TO THE | | | CURRENT CODE AND PROVIDE THE MINIMUM 50 POINTS PER | | | SECTION 94-442(G) BASED ON THE PLANT LIST AND ITEMS | | | THAT QUALIFY. SOME WORDING AND PERCENTAGES ARE NOT | | | CORRECT. | | | | | | 14. PROVIDE LOCATIONS OF LIGHTING ON THE LANDSCAPE PLAN | | | TO AVOID CONFLICTS WITH LANDSCAPING. | | | | | | 15. THERE APPEAR TO BE CONFLICTS IN MANY LOCATIONS | | | BETWEEN TREES AND DRAINAGE LINES, WATER AND SEWER LINES | | | ON THE LANDSCAPE PLAN. ADJUST LOCATIONS OF TREES OR | | | UTILITY LINES TO RESOLVE CONFLICTS WITH LANDSCAPING. | | | . | | | 16. PROVIDE LOCATIONS AND SCREENING FOR ALL ABOVE | | | GROUND UTILITY VALVES, BACKFLOW PREVENTERS, A/C UNITS, | | | AND FPL TRANSFORMERS. | | | | | | 17. SHOW LOCATIONS OF ANY ROOT BARRIERS REQUIRED TO | | | PROTECT UTILITY LINES AND PROVIDE A ROOT BARRIER | | | DETAIL. | | | | | | 18. SHOW COMPLIANCE WITH SECTION 94-445 L. PLANT | | | SPECIES. A MINIMUM OF 60 PERCENT OF PLANT MATERIAL | | | ADDED SHALL BE FLORIDA NATIVE OR DROUGHT TOLERANT | | | SPECIES SELECTED FROM THE CITY LIST OR THE LIST OF | | | SPECIES IN THE MOST RECENT EDITION OF SOUTH FLORIDA | | | WATER MANAGEMENT DISTRICT WATERWISE SOUTH FLORIDA | | | LANDSCAPES. | | | | | | | | | | | | CONDITIONS OF APPROVAL | | | 1. PRIOR TO THE REMOVAL OR RELOCATION OF ANY TREES ON | | | THE PROPERTY, A TREE ALTERATION PERMIT SHALL BE | | | SUBMITTED, REVIEWED AND APPROVED BY THE DEVELOPMENT | | | SERVICES DEPARTMENT, PLANNING DIVISION. | | | |
|
|
| Review Stop |
PARK |
PARKING |
| Rev No |
1 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
|
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
POLICE |
POLICE |
| Rev No |
1 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
|
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
PW |
PUBLIC WORKS |
| Rev No |
2 |
Status |
P |
Date |
12-04-2019 |
|
|
Cont ID |
|
| Sent By |
|
Date |
12-04-2019 |
Time |
|
Rev Time |
0.00 |
| Received By |
|
Date |
12-04-2019 |
Time |
|
Sent To |
|
|
| Notes |
| 2019-12-04 15:33:16 | NO FURTHER COMMENTS. |
|
|
| Review Stop |
PW |
PUBLIC WORKS |
| Rev No |
1 |
Status |
F |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
10-08-2019 |
Time |
|
Rev Time |
|
| Received By |
|
Date |
10-08-2019 |
Time |
|
Sent To |
|
|
| Notes |
| 2019-10-08 15:04:21 | | | | - FOR A FREESTANDING SITE DUMPSTER ENCLOSURE, THE | | | ENCLOSURE SHALL COMPLY WITH THE LATEST REVISION OF CITY | | | OF WEST PALM BEACH GENERAL CONSTRUCTION-GARBAGE | | | ENCLOSURE STANDARD, CG-8. | | | - PLEASE PROVIE A DESIGNATED LOCATION FOR THE BULK ITEM | | | PICK UP | | | | | | | | | MATT HEJAZI | | | DEPT. OF PUBLIC WORKS | | | [email protected] | | | 561-822-2045 | | | |
|
|
| Review Stop |
STORM |
STORMWATER |
| Rev No |
2 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
STORM |
STORMWATER |
| Rev No |
1 |
Status |
F |
Date |
10-08-2019 |
|
|
Cont ID |
|
| Sent By |
tward |
Date |
10-08-2019 |
Time |
16:47 |
Rev Time |
0.00 |
| Received By |
tward |
Date |
10-08-2019 |
Time |
16:49 |
Sent To |
|
|
| Notes |
| 2019-10-08 16:49:08 | THIS IS A CONCEPTUAL LEVEL REVIEW. CONSTRUCTION LEVEL | | | DETAILS, DESIGN CALCULATIONS AND THE POLLUTION | | | PREVENTION PLAN WILL BE REVIEWED AS PART OF THE | | | ENGINEERING DEVELOPMENT APPROVAL AND BUILDING PERMIT | | | APPLICATION PROCESSES. THE ENGINEERING DEVELOPMENT | | | APPROVAL APPLICATION FORMS CAN BE DOWNLOADED AT | | | HTTP://WPB.ORG/DEPARTMENTS/ENGINEERING-PUBLIC-WORKS/FOR | | | MS,-PERMITS-APPLICATIONS | | | | | | THE FOLLOWING COMMENTS MUST BE ADDRESSED PRIOR TO SITE | | | PLAN APPROVAL: | | | | | | 1. ADD THE CONVERSION EQUATION BETWEEN NAVD1988 AND | | | NGVD1929 VERTICAL DATUMS TO THE SURVEY AND ENGINEERING | | | PLANS. | | | | | | 2. POLLUTANT RETARDANT BAFFLES (PRB'S) SHOULD BE USED | | | IN ALL DRAINAGE STRUCTURES CONNECTED TO EXFILTRATION | | | TRENCH. | | | | | | 3. IDENTIFY WHICH DRAINAGE STRUCTURE WILL BE THE | | | CONTROL STRUCTURE. | | | | | | 4. DRAINAGE EASEMENT SHOLD BE OBTAINED FOR OUTFALL PIPE | | | CROSSING THE APARTMENTS? PARCEL. | | | | | | 5. SHOW AND LABEL THE PERIMETER BERM ALONG THE PROPERTY | | | BOUNDARIES. PROVIDE A CROSS SECTION DETAIL OF THE | | | PERIMETER BERM. | | | | | | 6. PROVIDE GRADING, CONTOURS AND/OR CROSS SECTION(S) OF | | | THE PERVIOUS AREA NEAR STRUCTURE S-7. | | | | | | 7. PROVIDE CROSS SECTION(S) OR GRADING/CONTOURS OF THE | | | PROPOSED DETENTION AREA. | | | | | | 8. LIST VERTICAL DATUM AND CONVERSION EQUATION ON EACH | | | SHEET CONTAINING ELEVATION INFORMATION. | | | | | | 9. CLARIFY THE MINIMUM BERM ELEVATION INFORMATION IN | | | THE TABLE ON SHEET C-140. | | | | | | 10. SHOW MILL AND RESURFACE LIMITS FOR THE TRENCH CUTS | | | ON VILLAGE BLVD. | | | | | | THE FOLLOWING COMMENTS MUST BE ADDRESSED PRIOR TO | | | ISSUANCE OF CONSTRUCTION AUTHORIZATION INCLUDING | | | BUILDING PERMITS AND ENGINEERING DEVELOPMENT APPROVAL. | | | | | | 1. AN ENGINEERING DEVELOPMENT APPROVAL APPLICATION MAY | | | BE REQUIRED FROM THE ENGINEERING SERVICES DEPARTMENT. | | | THE ENGINEERING DEVELOPMENT APPROVAL APPLICATION FORMS | | | CAN BE DOWNLOADED AT: HTTP://WPB.ORG/DEPARTMENTS/ENGINE | | | ERING-PUBLIC-WORKS/FORMS,-PERMITS-APPLICATIONS | | | | | | 2. EROSION CONTROL PLAN AND DETAILS TO BE SUBMITTED | | | WITH THE ENGINEERING PERMIT APPLICATION. | | | | | | 3. PROVIDE A COPY OF THE SFWMD ERP PRIOR TO STARTING | | | CONSTRUCTION. | | | | | | TRACY WARD, PE | | | SENIOR STORMWATER ENGINEER | | | ENGINEERING SERVICES DEPARTMENT | | | 561-494-1120 | | | [email protected] | | | |
|
|
| Review Stop |
SURVEY |
SURVEYING |
| Rev No |
2 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SURVEY |
SURVEYING |
| Rev No |
1 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
|
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
TRAFFIC |
TRAFFIC ENGINEERING |
| Rev No |
4 |
Status |
F |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
02-26-2020 |
Time |
|
Rev Time |
0.00 |
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2020-02-26 13:37:50 | SITE PLAN COMMENTS: | | | 1. PLANNED DEVELOPMENT (PD) IS REQUIRED TO BE | | | CONSISTENT WITH ALL ELEMENTS OF THE CITY'S | | | COMPREHENSIVE PLAN. PER THE CITY'S COMPREHENSIVE PLAN | | | TRANSPORTATION ELEMENT, CONSTRUCT A 12-FOOT SIDEWALK ON | | | VILLAGE BOULEVARD ALONG SITE FRONTAGE. THE COST | | | ESTIMATE FOR THE PROPOSED IN-LIEU PAYMENT DOES NOT | | | APPEAR TO INCLUDE DEMOLITION, MOT, MOBILIZATION, | | | STABILIZATION AND UTILITY ADJUSTMENT WHICH MAY BE | | | ESSENTIAL TO THE SIDEWALK IMPROVEMENT. | | | | | | | | | CONDITIONS: | | | 1. DEVELOPMENT ON THIS 5.53-ACRE PARCEL WITH THE | | | PROPOSED COMMUNITY SERVICE FLU DESIGNATION WOULD BE | | | RESTRICTED TO GENERATE NO MORE THAN 1,735 WEEKDAY DAILY | | | EXTERNAL TRIPS OR 173 WEEKDAY PEAK HOUR EXTERNAL TRIPS | | | WHEN EVALUATED USING THE LATEST PALM BEACH COUNTY TRIP | | | GENERATION RATES PER THE FLU AMENDMENT TRAFFIC | | | ANALYSIS. | | | | | | | | | SHING TSOI | | | CITY IN-HOUSE TRAFFIC CONSULTANT | | | 561-494-1141 | | | [email protected] | | | (IN-HOUSE ON TUESDAYS AND WEDNESDAYS) |
|
|
| Review Stop |
TRAFFIC |
TRAFFIC ENGINEERING |
| Rev No |
3 |
Status |
F |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
02-03-2020 |
Time |
|
Rev Time |
0.00 |
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2020-02-03 15:45:31 | SITE PLAN COMMENTS: | | | 1. PLANNED DEVELOPMENT (PD) IS REQUIRED TO BE | | | CONSISTENT WITH ALL ELEMENTS OF THE CITY?S | | | COMPREHENSIVE PLAN. CONSISTENT WITH THE CITY?S | | | COMPREHENSIVE PLAN TRANSPORTATION ELEMENT, CONSTRUCT A | | | 12-FOOT SIDEWALK ON VILLAGE BOULEVARD ALONG SITE | | | FRONTAGE. | | | | | | CONDITIONS: | | | 1. THE FLU AMENDMENT WILL BE VOLUNTARILY RESTRICTED TO | | | A FAR OF 0.23 PER THE FLU AMENDMENT TRAFFIC ANALYSIS OR | | | AS REVISED BASED ON THE REVISED FLU AMENDMENT TRAFFIC | | | ANALYSIS. | | | | | | | | | | | | SHING TSOI | | | CITY IN-HOUSE TRAFFIC CONSULTANT | | | 561-494-1141 | | | [email protected] | | | (IN-HOUSE ON TUESDAYS AND WEDNESDAYS) |
|
|
| Review Stop |
TRAFFIC |
TRAFFIC ENGINEERING |
| Rev No |
2 |
Status |
F |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
11-27-2019 |
Time |
|
Rev Time |
0.00 |
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2019-11-27 17:07:36 | FLU AMENDMENT TRAFFIC ANALYSIS COMMENTS: | | | 1. THE GENERALIZED SERVICE VOLUMES FOR VILLAGE | | | BOULEVARD SHOWN IN TABLE 8 ARE NOT CONSISTENT WITH THE | | | VOLUMES PUBLISHED IN PALM BEACH COUNTY?S TPS. PLEASE | | | VERIFY AND REVISE. ALSO, PLEASE USE THE LATEST ADOPTED | | | 2040 COST FEASIBLE MODEL VOLUMES (SERPM 7.0 ADJUSTED | | | VOLUMES) FROM PALM BEACH TPA DATED 8/17/2016. | | | 2. IN TABLE 6, THE COMMITTED TRAFFIC SHOWN DOES NOT | | | APPEAR TO BE CONSISTENT WITH THE INFORMATION PROVIDED | | | IN THE APPENDIX. PLEASE VERIFY. IF COMMITTED | | | INFORMATION ON VILLAGE BOULEVARD FROM THE COUNTY?S TPS | | | DATABASE IS USED, PLEASE INCLUDE IN THE APPENDIX. | | | 3. PLEASE REVISE THE TYPO IN THE TABLE ENTRY ?MAX | | | PROPOSED FLU - EXISTING FLU (SHORT-TERM ANALYSIS)? | | | WHICH SHOULD SAY ?LONG-TERM ANALYSIS? IN TABLE 3. | | | SITE PLAN COMMENTS: | | | 4. INCLUDE THE REQUIRED BICYCLE PARKING IN THE SITE | | | DATA TABLE AND INDICATE THE NUMBER OF BICYCLE PARKING | | | SPACES REQUIRED. | | | 5. THE RESPONSE INDICATED THAT THE EXISTING SHADE TREES | | | AND PEDESTRIAN CONNECTION ARE INNOVATIVE ELEMENTS FOR | | | PLANNED DEVELOPMENT (PD) IN THE PROPOSED SITE PLAN. | | | HOWEVER, THESE SHADE TREES AND SIDEWALK ON VILLAGE | | | BOULEVARD ARE EXISTING ELEMENTS. PD IS INTENDED FOR | | | DEVELOPMENTS WITH INNOVATIVE DESIGNS AND IS REQUIRED TO | | | BE CONSISTENT WITH ALL ELEMENTS OF CITY?S COMPREHENSIVE | | | PLAN. PLEASE IDENTIFY INNOVATIVE DESIGN ELEMENTS | | | ASSOCIATED WITH THIS CSPD. | | | 6. CONSTRUCT 12-FOOT SIDEWALK WITH 6-FOOT LANDSCAPE | | | BUFFER AND SHADE TREES ON VILLAGE BOULEVARD ALONG SITE | | | FRONTAGE. IT APPEARS THE EXISTING AND PROPOSED | | | RELOCATED SHADE TREES ARE SET BACK APPROXIMATELY 22 | | | FEET FROM THE CURB. ALSO, CONSIDER CONSTRUCTING THE | | | SIDEWALK AROUND THE SHADE TREES AND UTILITIES AS IT | | | APPEARS THERE ARE 24 FEET OF SPACE BETWEEN THE PARKING | | | SPACES AND SHADE TREES | | | CONDITIONS: | | | 1. THE FLU AMENDMENT WILL BE VOLUNTARILY RESTRICTED TO | | | A FAR OF 0.317 PER THE FLU AMENDMENT TRAFFIC ANALYSIS | | | OR AS REVISED BASED ON THE REVISED FLU AMENDMENT | | | TRAFFIC ANALYSIS. | | | | | | | | | SHING TSOI | | | CITY IN-HOUSE TRAFFIC CONSULTANT | | | 561-494-1141 | | | [email protected] | | | (IN-HOUSE ON TUESDAYS AND WEDNESDAYS) |
|
|
| Review Stop |
TRAFFIC |
TRAFFIC ENGINEERING |
| Rev No |
1 |
Status |
F |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
10-08-2019 |
Time |
|
Rev Time |
|
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2019-10-08 16:45:55 | FLU AMENDMENT TRAFFIC ANALYSIS COMMENTS: | | | 1. PROVIDE TRAFFIC ANALYSIS FOR FUTURE LANE USE | | | AMENDMENT FOR THE CHURCH SITE. | | | SITE PLAN COMMENTS: | | | 2. PROVIDE TURNAROUND SPACE FOR THE DEAD-END PARKING | | | NORTHWEST OF THE CHURCH. | | | 3. REDUCE DRIVEWAY WIDTH TO 24 FEET OR LESS. | | | 4. PROVIDE CROSS VEHICULAR ACCESS BETWEEN THE CHURCH | | | AND THE RESIDENTIAL DEVELOPMENT ALONG THE EAST SIDE OF | | | THE SITE, AND CROSS PEDESTRIAN ACCESSES ALONG THE EAST | | | AND NORTH SIDES OF THE SITE. | | | 5. INCLUDE THE REQUIRED BICYCLE PARKING IN THE SITE | | | DATA TABLE AND SITE PLAN. | | | 6. PLANNED DEVELOPMENT (PD) IS INTENDED FOR | | | DEVELOPMENTS WITH INNOVATIVE DESIGNS AND IS REQUIRED TO | | | BE CONSISTENT WITH ALL ELEMENTS OF CITY?S COMPREHENSIVE | | | PLAN. PLEASE IDENTIFY INNOVATIVE DESIGN ELEMENTS | | | ASSOCIATED WITH THIS CSPD. | | | 7. CONSTRUCT 12-FOOT SIDEWALK WITH 6-FOOT LANDSCAPE | | | BUFFER AND SHADE TREES ON VILLAGE BOULEVARD ALONG SITE | | | FRONTAGE. | | | 8. SIDEWALK SHOULD MAINTAIN THE SAME LEVEL AS THE | | | DRIVEWAYS. | | | | | | SHING TSOI | | | CITY IN-HOUSE TRAFFIC CONSULTANT | | | 561-494-1141 | | | [email protected] | | | (IN-HOUSE ON TUESDAYS AND WEDNESDAYS) |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
F |
Date |
01-30-2020 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
01-30-2020 |
Time |
10:01 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
01-30-2020 |
Time |
10:01 |
Sent To |
|
|
| Notes |
| 2020-01-30 10:01:49 | PLANS AND PLATS REVIEW COMMITTEE (PPRC) ZONING REVIEW | | | ________________________________________ | | | | | | DATE OF REVIEW: 01.29.2020 | | | PROJECT NO.: Z19090013 | | | CASE NO.: PB 1841A | | | ________________________________________ | | | | | | PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING | | | REVIEW COMMENTS: | | | | | | 1. [ PARTIALLY SATISFIED ] - WHAT IS THE BASIS FOR | | | USING 9-FOOT PARKING SPACES? IF EACH SPACE WERE REDUCED | | | TO THE CODE-REQUIRED MINIMUM OF 8 FEET 6 INCHES, A | | | SUBSTANTIAL AMOUNT OF LANDSCAPE AREA COULD BE | | | REINTRODUCED BACK INTO THE SITE. | | | | | | 1.1 [ NEW COMMENT ] - AS THE APPLICANT IS REQUESTING A | | | PLANNED DEVELOPMENT AND IS ATTEMPTING TO USE | | | "LANDSCAPING" AS AN INNVOATE FEATURE, STAFF IS | | | CONSIDERING A CONDITION OF APPROVAL THAT WOULD PROVIDE | | | FOR THE REDUCED SIZE OF THE PARKING STALLS. | | | | | | 2. [ SATISFIED ] - A 5-FOOT WIDE TERMINAL ISLAND IS | | | REQUIRED AT THE NORTH END OF THE FIRST ROW OF PARKING | | | (ROW OF 6 SPACES) THAT?S LOCATED ON THE RIGHT SIDE OF | | | THE SOUTH EAST ACCESS DRIVE. | | | | | | 3. [ PARTIALLY SATISFIED ] - WHAT IS THE BASIS FOR | | | HAVING TWO (2) DRIVE-AISLES (EACH 24-FEET WIDE) WITHIN | | | SUCH CLOSE PROXIMITY TO ONE ANOTHER (NORTHEAST OF THE | | | EXISTING LIFT STATION)? COULD ONE (1) OF THESE BE | | | ELIMINATED OR OTHERWISE BE RECONFIGURED TO REDUCE THE | | | AMOUNT OF PAVEMENT? | | | | | | 3.1 [ NEW COMMENT ] - WHY IS SO MUCH PAVEMENT BEING | | | PROVIDED FOR THE TURN-AROUND AREA? | | | | | | 4. [ PARTIALLY SATISFIED ] - STAFF WOULD LIKE TO | | | DISCUSS THE POSSIBILITY OF HAVING SOME OF THE PARKING | | | BE CONSTRUCTED AS GRASS PARKING. | | | | | | 4.1 [ NEW COMMENT ] - AS THE APPLICANT IS REQUESTING A | | | PLANNED DEVELOPMENT AND IS ATTEMPTING TO USE | | | "LANDSCAPING" AS AN INNVOATE FEATURE, STAFF IS | | | CONSIDERING A CONDITION OF APPROVAL THAT WOULD PROVIDE | | | FOR A PORTION OF THE PARKING BEING CONSTRUCTED AS GRASS | | | PARKING. OTHER THAN A STATEMENT FROM THE CHURCH, NO | | | STUDIES HAVE BEEN PROVIDED SHOWING HOW MUCH PARKING IS | | | ACTUALLY BEING USED TODAY AT VARIOUS TIMES, ETC. | | | | | | 5. [ PARTIALLY SATISFIED ] - THE TURN-AROUND IN THE | | | FIRST BAY OF DEAD-END PARKING IS DIMENSIONED AS ONLY | | | BEING 8 FEET WIDE, AND DOES NOT HAVE ANY FORM OF FLARE | | | TO ALLOW MANEUVERABILITY OUT OF THE TURN-AROUND SPACE. | | | | | | 5.1 [ NEW COMMENT ] - WHY IS SO MUCH PAVEMENT BEING | | | PROVIDED FOR THE TURN-AROUND AREA? | | | | | | 6. [ SATISFIED ] - THE TURN-AROUND IN THE LAST BAY OF | | | DEAD-END PARKING DOES NOT HAVE ANY FORM OF FLARE TO | | | ALLOW MANEUVERABILITY OUT OF THE TURN-AROUND SPACE. | | | | | | 7. [ SATISFIED ] - A 5-FOOT WIDE TERMINAL ISLAND IS | | | REQUIRED AT THE END OF THE FIRST BAY OF DEAD-END | | | PARKING; THE PROPOSED CONCRETE SIDEWALK IS ENCROACHING | | | INTO THE REQUIRED LANDSCAPE ISLAND. | | | | | | 8. [ SATISFIED ] - PLEASE CONFIRM THAT THE ROUTE SHOWN | | | FOR THE GARBAGE TRUCK IS ACCURATE. AS SHOWN, THE TRUCK | | | WOULD BE GOING SOUTHBOUND, BUT THEN HEAD NORTHBOUND | | | AFTER SERVICING THE SITE. FOR THE TRUCK TO CONTINUE | | | SOUTHBOUND, IT WOULD HAVE TO MAKE A U-TURN. | | | | | | 9. [ SATISFIED ] - DETAIL SHALL BE PROVIDED FOR THE | | | BICYCLE PARKING SHOWING THE STYLE OF THE PROPOSED RACK | | | AS WELL AS DIMENSIONS FOR PLACEMENT, ETC. THE STYLE AND | | | DIMENSIONS SHALL CONFORM TO THE CITY?S REQUIREMENTS | | | (CONTACT ME FOR ADDITIONAL INFORMATION, IF NECESSARY). | | | RESPONSE STATES THAT A DETAIL WAS PROVIDED ON SHEET | | | C-121, BUT NO DETAIL IS SHOWN. | | | | | | 10. [ NOT SATISFIED ] - UTILITY LETTER FROM COMCAST IS | | | STILL OUTSTANDING. | | | | | | 11. [ NOT SATISIFED ] - PLEASE CLARIFY WHY THE SITE | | | PLAN INDICATES THAT ONLY 87 PARKING SPACES ARE | | | REQUIRED. THE SITE DATA TABLE SHOULD SHOW THE | | | CALCULATIONS (# OF SEATS, SQUARE FOOTAGE, ETC.). | | | | | | 11.1 [ NEW COMMENT ] - SITE DATA TABLE HAS NOT BEEN | | | UPDATED TO REFLECT REQUIRED PARKING CALCULATION (# OF | | | SEATS, SQUARE FOOTAGET, ETC.) | | | | | | 12. [ NOT SATISFIED ] - THE WAIVER REQUEST TABLE | | | INDICATES THAT A 10 FOOT REAR SETBACK WAIVER IS | | | PROPOSED. THE REGULATIONS REQUIRE 15 FOOT REAR SETBACK | | | AND 10 FEET IS PROPOSED; THIS IS A 5 FOOT WAIVER, NOT | | | 10 FOOT. | | | | | | 12.1 [ NEW COMMENT ] - THE WAIVER TABLE HAS NOT BEEN | | | UPDATED TO REFLECT A 5 FOOT WAIVER REQUEST. | | | | | | 13. [ SATISFIED ] - THE BUILDING SETBACK TABLE ON SHEET | | | C-120 INDICATES THAT A 15 FOOT FRONT SETBACK IS | | | REQUIRED; HOWEVER, SEC. 94-203 STATES THAT A 25 FOOT | | | FRONT SETBACK IS REQUIRED. PLEASE ADJUST ACCORDINGLY. | | | | | | 14. [ SATISFIED ] - THE BUILDING SETBACK TABLE ON SHEET | | | C-120 INDICATES THAT A 15 FOOT SETBACK IS REQUIRED ON A | | | SIDE STREET; HOWEVER, SEC. 94-203 STATES THAT A 25 FOOT | | | CORNER SETBACK IS REQUIRED. PLEASE ADJUST ACCORDINGLY. | | | | | | 15. [ SATISFIED ] - PLEASE CONFIRM THAT THE PROVIDED | | | LOT COVERAGE IN THE SITE DATA TABLE ON SHEET C-120; IT | | | SEEMS THAT THE BUILDING FOOTPRINT IS LARGER THAN WHAT | | | IS BEING INDICATED. | | | | | | 16. [ SATISFIED ] - THE PLANS INDICATE THAT THE | | | EXISTING BUILDING IS TWO (2) STORIES IN HEIGHT, BUT THE | | | FAR SHOWN IN THE SITE DATA TABLE MATCHES THE BUILDING | | | COVERAGE THAT IS PROVIDED, WHICH WOULD INDICATE THAT IT | | | IS A ONE (1) STORY BUILDING. PLEASE CLARIFY. | | | | | | 17. [ SATISFIED ] - THE PROPOSED CROSS-ACCESS EASEMENT | | | SHOWN ON SHEET C-120 DOES NOT SEEM TO BE SUFFICIENT | | | WIDTH AT THE POINT WHERE IT TERMINATES AT THE NORTH | | | GATE OF THE RESIDENTIAL DEVELOPMENT. | | | | | | 18. [ PARTIALLY SATISIFED ] - THE SITE DATA TABLE ON | | | SHEET C-120 SHALL INDICATE THE NUMBER OF BICYCLE | | | PARKING SPACES REQUIRED, AS WELL AS THE NUMBER | | | PROPOSED. | | | | | | 18.1 [ NEW COMMENT ] - DATA TABLE SHOULD INDICATE THE | | | CALUCATION USED FOR BICYCLE PARKING (1 BICYCLE SPACE | | | PER 20 PARKING SPACES). | | | ________________________________________ | | | | | | PLEASE NOTE THE FOLLOWING WHEN RESUBMITTING: | | | | | | A) WRITTEN RESPONSES TO COMMENTS MADE BY ALL | | | DEPARTMENTS SHALL BE PROVIDED UPON RESUBMISSION. | | | | | | B) 15 SETS OF REVISED PLANS AND/OR DOCUMENTS SHALL BE | | | PROVIDED, ALONG WITH ONE (1) REDUCED COPY (11IN X | | | 17IN), AND AN ELECTRONIC COPY OF ALL PLANS. | | | | | | C) PLEASE NOTE THAT RE-SUBMITTALS MAY BE SUBJECT TO | | | ADDITIONAL COMMENTS. | | | | | | D) IF NO RESPONSE IS RECEIVED WITHIN 60 DAYS OF THE | | | ISSUANCE OF THESE COMMENTS, THE APPLICATION WILL BE | | | CONSIDERED WITHDRAWN AND ANY FURTHER ACTION WILL | | | REQUIRE SUBMISSION OF A NEW DEVELOPMENT APPLICATION. | | | | | | E) PLEASE NOTE THAT YOU WILL BE PERMITTED ONE (1) | | | RESUBMITTAL AT NO ADDITIONAL COST. IF PREVIOUSLY-ISSUED | | | COMMENTS CONTINUE TO NOT BE SUFFICIENTLY ADDRESSED, THE | | | APPLICANT WILL BE ACCESSED A RESUBMITTAL FEE. SUCH FEE | | | WILL BE 20% OF THE ORIGINAL APPLICATION FEE. | | | ________________________________________ | | | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | | | JOHN P. ROACH, AICP, PRINCIPAL PLANNER | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION | | | 401 CLEMATIS STREET - P.O. BOX 3147 | | | WEST PALM BEACH, FLORIDA 33402 | | | | | | P: 561.822.1448 | | | TTY: 800.955.8771 | | | E: [email protected] | | | | | | W: WPB.ORG | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
01-06-2020 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
01-06-2020 |
Time |
16:10 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
01-06-2020 |
Time |
16:10 |
Sent To |
|
|
| Notes |
| 2020-01-06 16:10:48 | PLANS AND PLATS REVIEW COMMITTEE (PPRC) ZONING REVIEW | | | ________________________________________ | | | | | | DATE OF REVIEW: 01.06.2020 | | | PROJECT NO.: Z19090013 | | | CASE NO.: PB 1841A | | | ________________________________________ | | | | | | PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING | | | REVIEW COMMENTS: | | | | | | 1. WHAT IS THE BASIS FOR USING 9-FOOT PARKING SPACES? | | | IF EACH SPACE WERE REDUCED TO THE CODE-REQUIRED MINIMUM | | | OF 8 FEET 6 INCHES, A SUBSTANTIAL AMOUNT OF LANDSCAPE | | | AREA COULD BE REINTRODUCED BACK INTO THE SITE. | | | | | | 2. A 5-FOOT WIDE TERMINAL ISLAND IS REQUIRED AT THE | | | NORTH END OF THE FIRST ROW OF PARKING (ROW OF 6 SPACES) | | | THAT?S LOCATED ON THE RIGHT SIDE OF THE SOUTH EAST | | | ACCESS DRIVE. | | | | | | 3. WHAT IS THE BASIS FOR HAVING TWO (2) DRIVE-AISLES | | | (EACH 24-FEET WIDE) WITHIN SUCH CLOSE PROXIMITY TO ONE | | | ANOTHER (NORTHEAST OF THE EXISTING LIFT STATION)? COULD | | | ONE (1) OF THESE BE ELIMINATED OR OTHERWISE BE | | | RECONFIGURED TO REDUCE THE AMOUNT OF PAVEMENT? | | | | | | 4. STAFF WOULD LIKE TO DISCUSS THE POSSIBILITY OF | | | HAVING SOME OF THE PARKING BE CONSTRUCTED AS GRASS | | | PARKING. | | | | | | 5. THE TURN-AROUND IN THE FIRST BAY OF DEAD-END PARKING | | | IS DIMENSIONED AS ONLY BEING 8 FEET WIDE, AND DOES NOT | | | HAVE ANY FORM OF FLARE TO ALLOW MANEUVERABILITY OUT OF | | | THE TURN-AROUND SPACE. | | | | | | 6. THE TURN-AROUND IN THE LAST BAY OF DEAD-END PARKING | | | DOES NOT HAVE ANY FORM OF FLARE TO ALLOW | | | MANEUVERABILITY OUT OF THE TURN-AROUND SPACE. | | | | | | 7. A 5-FOOT WIDE TERMINAL ISLAND IS REQUIRED AT THE END | | | OF THE FIRST BAY OF DEAD-END PARKING; THE PROPOSED | | | CONCRETE SIDEWALK IS ENCROACHING INTO THE REQUIRED | | | LANDSCAPE ISLAND. | | | | | | 8. PLEASE CONFIRM THAT THE ROUTE SHOWN FOR THE GARBAGE | | | TRUCK IS ACCURATE. AS SHOWN, THE TRUCK WOULD BE GOING | | | SOUTHBOUND, BUT THEN HEAD NORTHBOUND AFTER SERVICING | | | THE SITE. FOR THE TRUCK TO CONTINUE SOUTHBOUND, IT | | | WOULD HAVE TO MAKE A U-TURN. | | | | | | 9. DETAIL SHALL BE PROVIDED FOR THE BICYCLE PARKING | | | SHOWING THE STYLE OF THE PROPOSED RACK AS WELL AS | | | DIMENSIONS FOR PLACEMENT, ETC. THE STYLE AND DIMENSIONS | | | SHALL CONFORM TO THE CITY?S REQUIREMENTS (CONTACT ME | | | FOR ADDITIONAL INFORMATION, IF NECESSARY). RESPONSE | | | STATES THAT A DETAIL WAS PROVIDED ON SHEET C-121, BUT | | | NO DETAIL IS SHOWN. | | | | | | 10. UTILITY LETTER FROM COMCAST IS STILL OUTSTANDING. | | | | | | 11. PLEASE CLARIFY WHY THE SITE PLAN INDICATES THAT | | | ONLY 87 PARKING SPACES ARE REQUIRED. THE SITE DATA | | | TABLE SHOULD SHOW THE CALCULATIONS (# OF SEATS, SQUARE | | | FOOTAGE, ETC.). | | | | | | 12. THE WAIVER REQUEST TABLE INDICATES THAT A 10 FOOT | | | REAR SETBACK WAIVER IS PROPOSED. THE REGULATIONS | | | REQUIRE 15 FOOT REAR SETBACK AND 10 FEET IS PROPOSED; | | | THIS IS A 5 FOOT WAIVER, NOT 10 FOOT. | | | | | | 13. THE BUILDING SETBACK TABLE ON SHEET C-120 INDICATES | | | THAT A 15 FOOT FRONT SETBACK IS REQUIRED; HOWEVER, SEC. | | | 94-203 STATES THAT A 25 FOOT FRONT SETBACK IS REQUIRED. | | | PLEASE ADJUST ACCORDINGLY. | | | | | | 14. THE BUILDING SETBACK TABLE ON SHEET C-120 INDICATES | | | THAT A 15 FOOT SETBACK IS REQUIRED ON A SIDE STREET; | | | HOWEVER, SEC. 94-203 STATES THAT A 25 FOOT CORNER | | | SETBACK IS REQUIRED. PLEASE ADJUST ACCORDINGLY. | | | | | | 15. PLEASE CONFIRM THAT THE PROVIDED LOT COVERAGE IN | | | THE SITE DATA TABLE ON SHEET C-120; IT SEEMS THAT THE | | | BUILDING FOOTPRINT IS LARGER THAN WHAT IS BEING | | | INDICATED. | | | | | | 16. THE PLANS INDICATE THAT THE EXISTING BUILDING IS | | | TWO (2) STORIES IN HEIGHT, BUT THE FAR SHOWN IN THE | | | SITE DATA TABLE MATCHES THE BUILDING COVERAGE THAT IS | | | PROVIDED, WHICH WOULD INDICATE THAT IT IS A ONE (1) | | | STORY BUILDING. PLEASE CLARIFY. | | | | | | 17. THE PROPOSED CROSS-ACCESS EASEMENT SHOWN ON SHEET | | | C-120 DOES NOT SEEM TO BE SUFFICIENT WIDTH AT THE POINT | | | WHERE IT TERMINATES AT THE NORTH GATE OF THE | | | RESIDENTIAL DEVELOPMENT. | | | | | | 18. THE SITE DATA TABLE ON SHEET C-120 SHALL INDICATE | | | THE NUMBER OF BICYCLE PARKING SPACES REQUIRED, AS WELL | | | AS THE NUMBER PROPOSED. | | | ________________________________________ | | | | | | PLEASE NOTE THE FOLLOWING WHEN RESUBMITTING: | | | | | | A) WRITTEN RESPONSES TO COMMENTS MADE BY ALL | | | DEPARTMENTS SHALL BE PROVIDED UPON RESUBMISSION. | | | | | | B) 15 SETS OF REVISED PLANS AND/OR DOCUMENTS SHALL BE | | | PROVIDED, ALONG WITH ONE (1) REDUCED COPY (11IN X | | | 17IN), AND AN ELECTRONIC COPY OF ALL PLANS. | | | | | | C) PLEASE NOTE THAT RE-SUBMITTALS MAY BE SUBJECT TO | | | ADDITIONAL COMMENTS. | | | | | | D) IF NO RESPONSE IS RECEIVED WITHIN 60 DAYS OF THE | | | ISSUANCE OF THESE COMMENTS, THE APPLICATION WILL BE | | | CONSIDERED WITHDRAWN AND ANY FURTHER ACTION WILL | | | REQUIRE SUBMISSION OF A NEW DEVELOPMENT APPLICATION. | | | | | | E) PLEASE NOTE THAT YOU WILL BE PERMITTED ONE (1) | | | RESUBMITTAL AT NO ADDITIONAL COST. IF PREVIOUSLY-ISSUED | | | COMMENTS CONTINUE TO NOT BE SUFFICIENTLY ADDRESSED, THE | | | APPLICANT WILL BE ACCESSED A RESUBMITTAL FEE. SUCH FEE | | | WILL BE 20% OF THE ORIGINAL APPLICATION FEE. | | | | | | F) IN ORDER TO BE CONSIDERED FOR THE FEBRUARY 18, 2020, | | | PLANNING BOARD AGENDA, ALL COMMENTS SHALL BE | | | SATISFACTORILY ADDRESSED. PLEASE SUBMIT ALL REVISED | | | DOCUMENTS/PLANS NO LATER THAN FRIDAY, JANUARY 17, 2020. | | | | | | G) TO BE PLACED ON THE FEBRUARY 18, 2020, PLANNING | | | BOARD AGENDA, SIGNS SHALL BE POSTED ON THE PROPERTY NO | | | LATER THAN FEBRUARY 3, 2020. SIGNAGE SHALL CONFORM, AND | | | BE INSTALLED ACCORDING TO THE REQUIREMENTS OF THE | | | CITY?S ZONING AND LAND DEVELOPMENT REGULATIONS; SUCH | | | REQUIREMENTS ARE ALSO PROVIDED IN THE DEVELOPMENT | | | APPLICATION. A SIGNED AND NOTARIZED AFFIDAVIT SHALL BE | | | PROVIDED BY THE DEADLINE REFERENCED ABOVE. | | | | | | H) IF AFTER THE CASE HAS BEEN ADVERTISED THE APPLICANT | | | DESIRES TO REQUEST A CONTINUANCE, A FEE OF $50 PLUS THE | | | COST OF ADVERTISING WILL BE CHARGED. | | | ________________________________________ | | | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | | | JOHN P. ROACH, AICP, PRINCIPAL PLANNER | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION | | | 401 CLEMATIS STREET - P.O. BOX 3147 | | | WEST PALM BEACH, FLORIDA 33402 | | | | | | P: 561.822.1448 | | | TTY: 800.955.8771 | | | E: [email protected] | | | | | | W: WPB.ORG | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
10-09-2019 |
Time |
|
Rev Time |
0.00 |
| Received By |
pgreilic |
Date |
10-09-2019 |
Time |
16:58 |
Sent To |
|
|
| Notes |
| 2019-10-09 16:59:58 | CASE NUMBER: PB 1841 & 1841A (Z19090012/3) | | | PROJECT NAME: FAMILY CHURCH REZONING AND FUTURE LAND | | | USE MAP AMENDMENT | | | ADDRESS: 3600 VILLAGE BOULEVARD | | | | | | ---CONTACT PAUL GREILICH @ (561) 822-1443 OR JOHN ROACH | | | @ 561-822-1448 | | | ---PLEASE PROVIDE RESPONSES TO REVIEW COMMENTS IN | | | WRITTEN FORMAT. | | | ---WHEN RESUBMITTING, PLEASE PROVIDE A MINIMUM OF | | | ELEVEN (11) PAPER COPIES AND AN ELECTRONIC COPY IN | | | .PNG/.PDF FORMAT OF ALL PLANS. PLEASE NOTE THAT CHANGES | | | ON THE RESUBMITTED PLANS OR THE SUBMITTAL OF | | | INFORMATION/PLANS TO ADDRESS THE COMMENTS MAY RESULT IN | | | ADDITIONAL COMMENTS. | | | ---PLEASE NOTE THAT IF THE PLANNING DIVISION HAS NOT | | | RECEIVED A RESPONSE TO THE PPRC COMMENTS WITHIN 60 DAYS | | | FROM THE DATE OF THESE COMMENTS/THE PPRC MEETING (BY | | | 7/8/19), THE CASE SHALL BE CONSIDERED WITHDRAWN. ANY | | | FURTHER ACTION SHALL REQUIRE A NEW DEVELOPMENT | | | APPLICATION. | | | ---PUBLIC HEARING NOTIFICATION SIGNAGE SHALL BE POSTED | | | IN ACCORDANCE WITH THE REQUIREMENTS OF SECTION | | | 94-39(I)(5) OF THE ZONING AND LAND DEVELOPMENT | | | REGULATIONS. | | | | | | 1) PROVIDE AN EXPLANATION OF HOW THE APPLICATION AS | | | PRESENTED MEETS THE INTENT OF SEC. 94-207(A)(1), | | | INNOVATIVE LAND PLANNING AND DEVELOPMENT TECHNIQUES. | | | | | | 2) PROVIDE A PEDESTRIAN CONNECTION (SIDEWALK AND | | | ASSOCIATED STRIPING) ADJACENT TO DRIVE AISLE TO ENABLE | | | INCREASED PEDESTRIAN ACCESS TO THE SITE | | | | | | 3) CONSIDER A SHARED PARKING STRATEGY WITH THE PROPOSED | | | NEIGHBORING DEVELOPMENT TO REDUCE THE NUMBER OF PARKING | | | SPACE ON SITE. | | | | | | 4) THE PROPOSED PLAN INDICATES A TOTAL OF 163 SPACES | | | ARE BEING PROVIDED ABOVE WHAT IS REQUIRED BY CODE. HAS | | | THE PARKING DEMAND AT THE CHURCH HISTORICALLY BEEN | | | COMMENSURATE TO THE 250 EXISTING SPACES? APPLICANT TO | | | EXAMINE A POTENTIAL REDUCTION TO REDUCE IMPERVIOUS | | | SURFACE, RUNOFF. | | | | | | 5) ADD REQUIRED BICYCLE PARKING SPACES AND DISTRIBUTE | | | THROUGHOUT THE SITE AND INCLUDE CITY-STANDARD BIKE RACK | | | DETAIL | | | | | | 6) PROVIDE LETTERS FROM ALL OF THE FOLLOWING PUBLIC | | | UTILITIES CONFIRMING THAT THE PROPOSED PROJECT DOES NOT | | | ENCROACH INTO THEIR EASEMENTS OR OTHERWISE INTERFERE | | | WITH THE PROVISION OF THEIR SERVICES: AT&T, FPU, FPL, | | | AND COMCAST. | | | | | | 7) ALL PRIVATE DEVELOPMENT PROJECTS, INCLUDING NEW | | | CONSTRUCTION, OR THE RENOVATION OR IMPROVEMENT OF AN | | | EXISTING BUILDING, WHERE THE TOTAL CONSTRUCTION COSTS | | | ARE EQUAL OR GREATER THAN $750,000 IS SUBJECT TO THE | | | ART IN PUBLIC PLACES REQUIREMENTS OF CHAPTER 78, | | | ARTICLE V, OF THE CITY?S CODE OF ORDINANCES. CONTACT | | | SYBILLE WELTER @ 561-822-1521 OR [email protected] FOR | | | ADDITIONAL INFORMATION. | | | |
|
|
| |