Plan Review Details - Project Z19050026
| Plan Review Stops For Project Z19050026 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
06-11-2019 |
|
|
Cont ID |
|
| Sent By |
rbrown |
Date |
06-11-2019 |
Time |
21:51 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
06-11-2019 |
Time |
21:51 |
Sent To |
|
|
| Notes |
| 2019-06-11 22:18:12 | DEVELOPMENT SERVICES DEPARTMENT, BUILDING DIVISION, | | | COMMENTS: | | | | | | 1. THIS REVIEW IS A CURSORY REVIEW AS IT RELATES TO THE | | | SITE. IT IS NOT A REVIEW FOR FULL COMPLIANCE WITH | | | FLORIDA BUILDING CODE. THE FOLLOWING COMMENTS ARE TO BE | | | ADDRESSED FOR THE BUILDING PERMIT APPLICATION. | | | | | | 2. DEMOLITION OF THE EXISTING BUILDING. AN ASBESTOS | | | SURVEY SHALL BE PERFORMED AND AN ASBESTOS ABATEMENT | | | REPORT SUBMITTED TO THE HEALTH DEPARTMENT PALM BEACH | | | COUNTY OFFICE. CONTACT ALEX ORTEGA AT (561) 837-5963, | | | OR BY EMAIL: [email protected] | | | | | | 3. UNITY OF TITLE. FOR ANY BUILDING CROSSING A PROPERTY | | | LINE, EITHER A RECORDED UNITY OF TITLE, OR SOME OTHER | | | APPROVED LEGAL INSTRUMENT, SHALL BE INCLUDED WITH THE | | | PERMIT APPLICATION, OR THE BUILDING MUST HAVE A FIRE | | | WALL ALONG THE PROPERTY LINE, PER SECTION 202 OF | | | FLORIDA BUILDING CODE, BUILDING, FIRE SEPARATION | | | DISTANCE. | | | | | | 4. ACCESSIBLE ROUTE. WHEN SUBMITTED FOR PERMIT, THE | | | PLANS SHALL SHOW AT LEAST ONE ACCESSIBLE ROUTE, | | | COMPLYING WITH SECTIONS 206.2 AND 402.2 OF FLORIDA | | | ACCESSIBILITY CODE, FROM THE PUBLIC RIGHT-OF-WAY TO ALL | | | ACCESSIBLE BUILDING OR FACILITY ENTRANCES. | | | | | | 5. ANY PART OF AN ACCESSIBLE ROUTE WITH A SLOPE GREATER | | | THAN 1:20 SHALL BE CONSIDERED A RAMP AND SHALL COMPLY | | | WITH SECTION 405 OF FLORIDA ACCESSIBILITY CODE. | | | | | | 6. BUILDING SIZE. WHEN SUBMITTED FOR BUILDING PERMIT, | | | THE PLANS SHALL SHOW THAT THE TYPE OF CONSTRUCTION FOR | | | THE BUILDINGS WILL BE IN ACCORDANCE WITH THE HEIGHT, | | | AREA AND OCCUPANCY LIMITATIONS IN CHAPTER 5 OF THE | | | FLORIDA BUILDING CODE. | | | | | | 7. SEPARATE PERMITS REQUIRED. ALL APPLICABLE PERMITS | | | AND SUB-PERMITS MUST BE OBTAINED BEFORE COMMENCING THE | | | WORK. SEPARATE PERMITS, PLANS AND FEES, ARE REQUIRED | | | FOR SIGNS, GAS SYSTEMS, GENERATORS, FIRE ALARM SYSTEMS, | | | FIRE SPRINKLER AND OTHER FIRE SUPPRESSION SYSTEMS, | | | GREASE INTERCEPTORS, SITE LIGHTING, SITE LANDSCAPE, | | | SITE IRRIGATION, ETC. | | | | | | 8. PROTECTION OF NEIGHBORING PROPERTY. PROPERTY OWNER | | | AND CONTRACTOR SHALL PROTECT ALL NEIGHBORING PROPERTY, | | | INCLUDING VEHICLES, FROM DAMAGE OR DIRT CAUSED BY THE | | | CONSTRUCTION, AND SHALL NOTIFY THE OCCUPANTS OF | | | NEIGHBORING PROPERTIES ABOUT ALL STAGES OF CONSTRUCTION | | | THAT MAY AFFECT THE USE OF THEIR PROPERTY. | | | | | | 9. ART IN PUBLIC PLACES. IF THE COST OF NEW VERTICAL | | | CONSTRUCTION EXCEEDS $750,000 THIS PROJECT WILL BE | | | SUBJECT TO ART IN PUBLIC PLACES (AIPP) ASSESSMENT. FOR | | | ADVICE ON THE PROVISION OF PUBLIC ARTWORK IN LIEU OF | | | THE AIPP ASSESSMENT, CONTACT SYBILLE WELTER, ART IN | | | PUBLIC PLACES COORDINATOR, AT (561) 822-1521, OR BY | | | EMAIL: [email protected] | | | | | | ROBERT BROWN | | | BUILDING OFFICIAL | | | TEL: 561 805 6652 | | | EMAIL: [email protected] | | | |
|
|
| Review Stop |
ENG - PPRC |
ENGINEERING - PPRC |
| Rev No |
4 |
Status |
N |
Date |
12-31-2019 |
|
|
Cont ID |
|
| Sent By |
rrossano |
Date |
12-31-2019 |
Time |
|
Rev Time |
0.00 |
| Received By |
rrossano |
Date |
12-31-2019 |
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
ENG - PPRC |
ENGINEERING - PPRC |
| Rev No |
3 |
Status |
P |
Date |
10-11-2019 |
|
|
Cont ID |
|
| Sent By |
rrossano |
Date |
10-11-2019 |
Time |
|
Rev Time |
0.00 |
| Received By |
rrossano |
Date |
10-11-2019 |
Time |
|
Sent To |
|
|
| Notes |
| 2019-10-11 10:49:41 | PASSED WITH PROVISO: | | | | | | THE CITY OF WEST PALM BEACH IS SEEKING ABANDONMENT OF | | | THE EXISTING 10 IN. EAST - WEST WATER MAIN WITHIN | | | LIMITS OF SUBJECT PROPERTY. DEVELOPER SHALL WORK IN | | | CONJUNCTION WITH CITY TO THAT END AS A CONDITION OF | | | APPROVAL. | | | | | | FEEL FREE TO CONTACT US IF YOU HAVE ANY QUESTIONS OR | | | CONCERNS, THANKS. | | | | | | RICK ROSSANO, PROJECT COORDINATOR | | | ENGINEERING SERVICES DEPARTMENT | | | 401 CLEMATIS STREET, 4TH FLOOR | | | WEST PALM BEACH, FL 33401 (MAILING ADDRESS: P.O. BOX | | | 3366, ZIP 33402) | | | MAIN PHONE: (561) 822-1200 DIRECT: (561) 494-1098 | | | FAX: (561) 494-1116 MOBILE: (561) 246-9525 | | | EMAIL: [email protected] WWW.WPB.ORG/ENGINEERING | | | | | | MANNY GONZALEZ, SENIOR ENGINEERING PROJECT COORDINATOR | | | ENGINEERING SERVICES DEPARTMENT | | | 401 CLEMATIS STREET, 4TH FLOOR | | | WEST PALM BEACH, FL 33401 (MAILING ADDRESS: P.O. BOX | | | 3366, ZIP 33402) | | | MAIN PHONE: (561) 822-1200 DIRECT: (561) 494-1085 | | | FAX: (561) 494-1116 MOBILE: (561) 644-7301 | | | EMAIL: [email protected] WWW.WPB.ORG/ENGINEERING | | | |
|
|
| Review Stop |
ENG - PPRC |
ENGINEERING - PPRC |
| Rev No |
2 |
Status |
F |
Date |
08-21-2019 |
|
|
Cont ID |
|
| Sent By |
rrossano |
Date |
08-21-2019 |
Time |
|
Rev Time |
0.00 |
| Received By |
rrossano |
Date |
08-21-2019 |
Time |
|
Sent To |
|
|
| Notes |
| 2019-08-21 09:38:58 | ENGINEER OF RECORD SHALL MEET WITH CITY ENGINEERING TO | | | DISCUSS WATER/SEWER DESIGN OPTIONS. | | | | | | PLEASE CONTACT: | | | | | | MANNY GONZALEZ | | | SENIOR ENGINEERING PROJECT COORDINATOR | | | ENGINEERING SERVICES DEPARTMENT | | | 401 CLEMATIS STREET, 4TH FLOOR | | | WEST PALM BEACH, FL 33401 | | | (MAILING ADDRESS: P.O. BOX 3366, ZIP 33402) | | | MAIN PHONE: (561) 822-1200 | | | DIRECT: (561) 494-1085 | | | FAX: (561) 494-1116 | | | MOBILE: (561) 644-7301 | | | EMAIL: [email protected] | | | WWW.WPB.ORG/ENGINEERING | | | |
|
|
| Review Stop |
ENG - PPRC |
ENGINEERING - PPRC |
| Rev No |
1 |
Status |
F |
Date |
06-07-2019 |
|
|
Cont ID |
|
| Sent By |
rrossano |
Date |
06-07-2019 |
Time |
|
Rev Time |
2.00 |
| Received By |
rrossano |
Date |
06-07-2019 |
Time |
|
Sent To |
|
|
| Notes |
| 2019-06-07 08:37:38 | THE CITY OF WEST PALM BEACH HAS A NUMBER OF REGULATIONS | | | AND PERMIT REQUIREMENTS WHICH DIRECTLY AFFECT THE | | | DEVELOPMENT AND INSTALLATION OF WATER AND WASTEWATER | | | UTILITIES WITHIN THE CITY. PLEASE SEE DEVELOPMENT | | | PERMIT SUBMITTAL REQUIREMENTS AT THE LINK BELOW: | | | HTTP://WPB.ORG/CMSPAGES/GETAMAZONFILE.ASPX?PATH=~\WPB_W | | | EBSITE\MEDIA\ENGINEERING\DEVELOPMENT-APPLICATION-FULL-P | | | ACKAGE_2016.PDF&HASH=7BD4DD7EB6115181D8C5977BCC02A97B19 | | | 60045731D3658206F27451722716EF | | | THIS AND OTHER RELATED ENGINEERING DOCUMENTS CAN BE | | | FOUND HERE: | | | HTTP://WPB.ORG/DEPARTMENTS/ENGINEERING-PUBLIC-WORKS/FOR | | | MS,-PERMITS-APPLICATIONS | | | | | | CODE OF ORDINANCES, CITY OF WEST PALM BEACH, FLORIDA, | | | CODIFIED THROUGH ORD. NO. 4183-08, ADOPTED SEPT. 22, | | | 2008. (SUPPLEMENT NO. 18) | | | CHAPTER 90 UTILITIES, ARTICLE I. IN GENERAL, | | | SEC. 90-7. POLICY REGARDING EXTENSION OF WATER OR SEWER | | | SERVICE FACILITIES OF THE CITY. | | | | | | THE WATER AND WASTEWATER SERVICE AGREEMENTS AND THE | | | CONSTRUCTION PERMITS ADDRESS RESERVATION OF CAPACITY | | | BASED ON USAGE, METER SIZE AND FEES, DESIGN STANDARDS, | | | BACKFLOW PREVENTION, FIRE SERVICE AND IRRIGATION. | | | | | | PROVIDE CALCULATIONS ON PLANS OF EXISTING AND PROPOSED | | | DEMANDS FOR WATER & SEWER (AVERAGE, MAXIMUM AND PEAK) | | | AND FIRE FLOW DEMANDS. CALCULATIONS SHALL BE PER FAC | | | 64E-6 FOR SEWER AND PER FAC 64-E.008 FOR WATER. | | | | | | PROVIDE CCTV VIDEO OF EXISTING SANITARY SEWER ALONG | | | ENTIRE PROJECT FRONTAGE. | | | | | | PLEASE SUBMIT A FORMAL AS-BUILT REQUEST FOR ALL CITY OF | | | WEST PALM BEACH-OWNED UTILITIES WITHIN THE PUBLIC RIGHT | | | OF WAY FOR THE ENTIRE EXTENT OF THE LIMITS OF YOUR | | | PROJECT. IDENTIFY TYPE OF UTILITY, LOCATION, PIPE | | | MATERIAL, AGE AND SIZE. PLEASE CONTACT JANICE TARBILL | | | IN THE WPB ENGINEERING SERVICES DEPARTMENT AT | | | [email protected] OR 561-494-1079 FOR FURTHER | | | ASSISTANCE. NOTE THAT FIELD RECORDS ARE FOR INFORMATION | | | ONLY. FIELD VERIFY UTILITY LOCATIONS USING FIELD | | | SURVEY, POT-HOLING, SOFT DIGS ETC. | | | | | | AS OF DECEMBER 20, 2015, THE CITY OF WEST PALM BEACH | | | CROSS-CONNECTION CONTROL MANUAL HAS BEEN REVISED, | | | STATING "ALL BACKFLOW DEVICES MUST BE LEAD-FREE". FOR | | | MORE INFORMATION, REFER TO THE LINK BELOW: | | | HTTP://WPB.ORG/DEPARTMENTS/PUBLIC-UTILITIES/FORMS-PUBLI | | | CATIONS/BACKFLOW-CROSS-CONNECTION-CONTROL-MANUAL | | | | | | PLANS SHALL SHOW PROPOSED LOCATIONS AND DIMENSIONS OF | | | ALL WATER, STORMWATER, AND SANITARY AND SEWER LINES, | | | INCLUDING STUBS TO EACH PROPERTY LINE FOR WATER AND | | | SANITARY SEWERS, THE MAKE AND MODEL OF ALL VALVES, | | | METERS, AND OTHERS DEVICES TO BE INSTALLED ON THE | | | SYSTEM, CATCH BASINS, CULVERTS, DITCHES INCLUDING | | | GRADES, PIPES SIZES, MATERIALS, ELEVATIONS, | | | ASSUMPTIONS, CALCULATIONS, INVERT ELEVATIONS FOR ALL | | | INLETS AND MANHOLES AND PROFILES OF SANITARY SEWER | | | LINES. ALL AVAILABLE ELEVATION SHALL BE SHOWN ON THE | | | PROFILE VIEW. DIRECTION OF FLOW SHALL BE SHOWN ON PLAN | | | VIEW ON PLAN VIEW FOR ALL SANITARY AND STORM SEWERS. | | | ADDITIONALLY, PLAN VIEW SHALL SHOW ALL EXISTING AND | | | PROPOSED UNDERGROUND UTILITY LAYOUT, INCLUDING FIBER | | | OPTIC, ELECTRIC, GAS, AND CABLEVISION & | | | TELECOMMUNICATION FACILITIES LOCATED ON THE | | | RIGHT-OF-WAY. PROVIDE PROFILE AND CLEARANCES AT ALL | | | UTILITY CROSSINGS. | | | | | | SHOW VERTICAL DATUM AND DATUM CONVERSION INFORMATION | | | (NAVD 88 AND NGVD 29). | | | | | | CUT AND CAP UTILITIES NOT IN USE, AND REMOVE ANY | | | ABANDONED UTILITY LINES LARGER THAN 2 INCHES FROM CITY | | | RIGHT OF WAY. | | | | | | PLEASE SUBMIT COMPLETED LOS ANALYSIS SUMMARY TABLE | | | DIRECTLY TO ENGINEERING (SHEET 33 OF CITY OF WPB | | | DEVELOPMENT APPLICATION). | | | | | | PLEASE PROVIDE CALCULATIONS OF REVISED PERVIOUS AND | | | IMPERVIOUS CALCULATIONS FOR THE PROPOSED IMPACTED | | | AREAS. | | | | | | PROVIDE UTILITY EASEMENTS TO ALLOW ACCESS FOR CITY | | | PERSONNEL TO PROPOSED UTILITIES INCLUDING WATER METERS. | | | | | | PROVIDE ONSITE CLEANOUTS NEAR PROPERTY LINE FOR | | | PROPOSED SANITARY LATERALS. | | | | | | PROVIDE ENLARGED DETAIL ON PLANS OF PROPOSED LOCATION | | | OF WATER METER AND BACKFLOW PREVENTION. | | | | | | SHOW ANY AND ALL EXISTING UTILITY EASEMENTS. | | | | | | FEEL FREE TO CONTACT US IF YOU HAVE ANY QUESTIONS OR | | | CONCERNS, THANKS. | | | | | | RICK ROSSANO | | | PROJECT COORDINATOR | | | ENGINEERING SERVICES DEPARTMENT | | | 401 CLEMATIS STREET, 4TH FLOOR | | | WEST PALM BEACH, FL 33401 | | | (MAILING ADDRESS: P.O. BOX 3366, ZIP 33402) | | | MAIN PHONE: (561) 822-1200 | | | DIRECT: (561) 494-1098 | | | FAX: (561) 494-1116 | | | MOBILE: (561) 246-9525 | | | EMAIL: [email protected] | | | WWW.WPB.ORG/ENGINEERING | | | | | | MANNY GONZALEZ | | | SENIOR ENGINEERING PROJECT COORDINATOR | | | ENGINEERING SERVICES DEPARTMENT | | | 401 CLEMATIS STREET, 4TH FLOOR | | | WEST PALM BEACH, FL 33401 | | | (MAILING ADDRESS: P.O. BOX 3366, ZIP 33402) | | | MAIN PHONE: (561) 822-1200 | | | DIRECT: (561) 494-1085 | | | FAX: (561) 494-1116 | | | MOBILE: (561) 644-7301 | | | EMAIL: [email protected] | | | WWW.WPB.ORG/ENGINEERING | | | | | | CENTRAL OPERATIONS CENTER (DISPATCH): | | | 24-HOUR EMERGENCY RESPONSE SERVICES TO PUBLIC | | | UTILITIES, PUBLIC WORKS, PARKS, ETC. 561-822-2210 | | | | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
4 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
10-04-2019 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
10-04-2019 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
10-04-2019 |
Time |
12:39 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
08-14-2019 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
08-14-2019 |
Time |
09:06 |
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
08-14-2019 |
Time |
09:06 |
Sent To |
|
|
| Notes |
| 2019-08-14 09:08:07 | 2ND REVIEW RESPONSE | | | | | | AFTER A REVIEW OF THE PPRC INFORMATION PACKET AND | | | RESPONSE LETTER DATED JULY 22, 2019, FROM URBAN DESIGN | | | KILDAY STUDIOS, TO JOHN P. ROACH, AICP, PRINCIPLE | | | PLANNER, THE PREVIOUSLY SUBMITTED FIRE PREVENTION | | | BUREAU COMMENTS HAVE BEEN ADDRESSED. | | | | | | THE BUREAU'S APPROVAL OF THIS SUBMITTED PROJECT DOES | | | NOT CONSTITUTE IT'S FINAL REVIEW OR APPROVAL. | | | | | | THE BUREAU SHALL REVIEW ALL SUBMITTED BUILDING PLANS AT | | | THE APPROPRIATE TIME AND IN ACCORDANCE WITH THE | | | REQUIREMENTS OF ALL APPLICABLE CODES AND STANDARDS. | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | WEST PALM BEACH FIRE RESCUE | | | 561-804-4709 | | | [email protected] | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
06-04-2019 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
06-04-2019 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
06-04-2019 |
Time |
15:09 |
Sent To |
|
|
| Notes |
| 2019-06-04 15:16:30 | THE FOLLOWING COMMENTS WERE SUBMITTED BY PETER LEDUC, | | | FIRE MARSHAL, BUREAU OF FIRE PREVENTION, WEST PALM | | | BEACH FIRE RESCUE. | | | | | | THIS REVIEW CAN ONLY BE CONSIDERED PRELIMINARY AS THE | | | DRAWINGS THAT WERE REVIEWED WERE NOT COMPLETE. | | | ADDITIONAL COMMENTS CAN BE EXPECTED WHEN FULL DRAWINGS | | | ARE SUBMITTED FOR PERMIT. | | | | | | THE FIRE PREVENTION BUREAU HAS NO OBJECTIONS TO THE | | | PROPOSED PROJECT. | | | | | | 1. CONSTRUCTION, DEMOLITION, AND RENOVATION TO COMPLY | | | WITH NFPA 241. EXTRA ATTENTION SHALL BE GIVEN TO THE | | | PERMITTING AND LOCATION OF CONSTRUCTION TRAILERS. A | | | PERMIT IS REQUIRED FOR ANY CONSTRUCTION TRAILER RELATED | | | TO THIS PROJECT. SEPARATION DISTANCES FROM MAIN | | | STRUCTURES AS WELL AS OTHER TRAILERS SHALL BE CLOSELY | | | MONITORED FOR THE REQUIREMENTS OF FIRE SPRINKLER | | | PROTECTION. | | | | | | 2. SITE ACCESS AND EXIT POINTS ARE TO BE CLEARLY | | | IDENTIFIED AND MAINTAINED FOR EMERGENCY VEHICLES DURING | | | ALL CONSTRUCTION ACTIVITIES. | | | | | | ANY PROPOSED TEMPORARY CONSTRUCTION FENCING HAS 20' | | | ACCESS WIDTH FOR FD USE IN CASE OF EMERGENCY. IT IS | | | RECOMMENDED THAT ANY GATE HAVE KNOX PADLOCKS FOR FD | | | USE. | | | | | | 3. THE BUILDING ADDRESS SHALL BE CLEARLY VISIBLE FROM | | | ALL ACCESS ROADWAYS, INCLUDING DURING CONSTRUCTION. | | | ADDRESS NUMBERS SHALL CONTRAST WITH THEIR BACKGROUND | | | AND SHALL NOT BE LESS THAN SIX (6) INCHES IN HEIGHT | | | WITH A ONE (1) INCH STROKE FOR ALL BUILDINGS. | | | | | | 4. DURING CONSTRUCTION, TRASH AND DEBRIS IS TO BE | | | REMOVED FROM THE SITE DAILY OR MORE OFTEN TO REDUCE THE | | | ACCUMULATION OF POTENTIAL LIFE AND FIRE SAFETY HAZARDS. | | | | | | 5. THE CONSTRUCTION OF THE BUILDING SHALL COMPLY WITH | | | THE 6TH EDITION OF THE FLORIDA FIRE PREVENTION CODE, | | | INCLUDING NFPA 1 & 101, AND ALL ASSOCIATED FIRE CODES. | | | | | | 6. FOR PLAN REVIEW SUBMITTAL, PLEASE INCLUDE THE | | | OCCUPANCY TYPE, PER THE FLORIDA FIRE PREVENTION CODE, | | | AND WHETHER IT THERE IS MIXED OR SEPARATED OCCUPANCY. | | | | | | 7. FOR PLAN REVIEW SUBMITTAL, PLEASE ENSURE THAT A FIRE | | | LOAD CALCULATION IS INCLUDED AND THAT ADEQUATE WATER | | | SUPPLY IS EXISTING OR WILL BE PROVIDED. | | | | | | 8. ALL EXISTING AND NEW FIRE HYDRANTS PLANNED FOR THIS | | | DEVELOPMENT SHALL BE CLEARLY INDICATED AND IDENTIFIED | | | ON THE PLAN AND CLOSELY COORDINATED WITH THE BUREAU OF | | | FIRE PREVENTION. | | | | | | ALL NEW FIRE HYDRANTS AND FDC'S PLANNED FOR THIS | | | DEVELOPMENT SHALL BE CLOSELY COORDINATED WITH THE | | | BUREAU OF FIRE PREVENTION. PROPOSED FIRE HYDRANTS AND | | | FDC?S SHOULD BE LOCATED WITH 100' OF EACH OTHER AND ON | | | THE SAME SIDE OF THE STREET(IF POSSIBLE) OR ACCESS | | | ROADWAY TO ALLOW FREE ACCESS FOR OTHER ARRIVING | | | EMERGENCY VEHICLES. | | | | | | 9. PROVIDE FOR A FIRE SPRINKLER AND/OR FIRE ALARM PER | | | THE APPLICABLE OCCUPANCY CODE. FOR ANY LIFE SAFETY | | | ENGINEERED SYSTEM, I.E FIRE SPRINKLER AND FIRE ALARM, | | | ENSURE THEY COMPLY WITH THE REQUIREMENTS OF FS 61G AND | | | SUBMITTED WITH THE MASTER PLAN. | | | | | | 10. COMPLETE LIFE SAFETY PLANS FOR EACH OCCUPANCY SHALL | | | BE PROVIDED THAT ILLUSTRATE OCCUPANT LOADS, TRAVEL | | | DISTANCES, COMMON PATHS OF TRAVEL, DEAD-END CORRIDORS, | | | EXIT SIGNS, EMERGENCY LIGHTING, EXITS LEADING TO A | | | PUBLIC WAY, FIRE EXTINGUISHER LOCATIONS, AND ALL FIRE | | | SAFETY FEATURES AND EQUIPMENT. | | | | | | THERE APPEARS TO BE LARGE MERCANTILE SPACES WITH | | | LIMITED EXITS. PLEASE ENSURE THE CODE REQUIREMENTS OF | | | THE OCCUPANCY AND EGRESS CODES ARE MET. | | | | | | IT APPEARS THERE IS A COMMON EGRESS CORRIDOR AT THE | | | REAR OF THESE OCCUPANCY THAT LEAD TO AN EXTERIOR | | | LOADING DOCK. THERE APPEARS TO BE ONLY ONE EXIT STAIR | | | THAT DOES NOT MEET THE EGRESS WIDTH REQUIREMENT OF THE | | | TOTAL OCCUPANTS THAT MAY USE THIS CORRIDOR.PLEASE | | | ENSURE THE CODE REQUIREMENTS OF THE OCCUPANCY AND | | | EGRESS CODES ARE MET. | | | | | | 11. IT IS HIGHLY RECOMMENDED (REQUIRED WITH FIRE | | | SPRINKLER SYSTEM) THAT A KNOX BOX WITH KEYS FOR ENTRY | | | DOOR LOCKS BE PROVIDED FOR 24 HOUR EMERGENCY ACCESS. | | | | | | 12. THE BUREAU'S APPROVAL OF THIS SUBMITTED PROJECT | | | DOES NOT CONSTITUTE ITS FINAL REVIEW OR APPROVAL. | | | | | | 13. THE BUREAU SHALL REVIEW ALL SUBMITTED BUILDING | | | PLANS AT THE APPROPRIATE TIME AND IN ACCORDANCE WITH | | | THE REQUIREMENTS OF ALL APPLICABLE CODES AND STANDARDS. | | | | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
4 |
Status |
P |
Date |
01-08-2020 |
|
|
Cont ID |
|
| Sent By |
rcaranci |
Date |
01-08-2020 |
Time |
11:39 |
Rev Time |
0.00 |
| Received By |
rcaranci |
Date |
01-08-2020 |
Time |
11:39 |
Sent To |
|
|
| Notes |
| 2020-01-08 11:40:03 | FROM: RAY CARANCI, LANDSCAPE PLANNER 561-822-1462 | | | PROJECT: SHOPS AT THE PRESS Z19050026 | | | OCTOBER 11, 2019 | | | I HAVE REVIEWED THE ABOVE REFERENCED PETITION, AND | | | PROVIDE THE FOLLOWING COMMENTS: | | | | | | 1. MAKE THE FOLLOWING CORRECTIONS TO THE TREE | | | DISPOSITION PLAN: | | | ? SATISFIED. IDENTIFY SPECIES OF ALL TREES AND PALMS ON | | | THE TREE DISPOSITION LIST. | | | ? SATISFIED. TREES AND PALMS CANOPY SQUARE FOOTAGE TO | | | BE MITIGATED BASED ON CATEGORY. ANY TREES 20 FEET OR | | | MORE CANOPY DIAMETER TO BE MITIGATED BY ACTUAL SQUARE | | | FOOTAGE. | | | ? SATISFIED. PROVIDE THE TOTAL SQUARE FOOTAGE OF | | | MITIGATION FOR ALL TREES AND PALMS PROPOSED TO BE | | | REMOVED. | | | ? SATISFIED. PROVIDE THE REPLACEMENT MITIGATION VALUES | | | BY CATEGORY FOR THE PROPOSED TREES AND PALMS. | | | THE CHART NECESSARY IS TO SHOW THE TOTAL SQUARE FOOTAGE | | | REQUIRED FOR MITIGATION BY ADDING ALL THE REMOVALS | | | TOGETHER. THE NEW TREES ADDED IN THE PLANT LIST ARE TO | | | BE GIVEN VALUES BY CATEGORY, THEN SUBTOTAL FOR EACH | | | SPECIES, THEN ADD THE TOTAL PROVIDED. STAFF | | | CALCULATIONS ARE 8971 SQ FT MITIGATION DUE, 4950 | | | PROVIDED NEW, AND TOTAL DIFFERENCE IS 4021 SQ FT TO | | | CALCULATE PAYMENT INTO TREE MITIGATION FUND. THIS COULD | | | BE REDUCED BY RELOCATING THE 2 LARGE LIVE OAK TREES. | | | RECALCULATE ALL MITIGATION DUE BASED ON COMMENT 2 | | | BELOW, AND IF PAYMENT IN LIEU IS REQUIRED, CALCULATE | | | THE AMOUNT DUE BY USING THE AVERAGE PRICE BY SPECIES | | | FOR A 12 FOOT GRADE ONE REPLACEMENT TREE AND MULTIPLY | | | BY TWO FOR INSTALLATION, PER SECTION 94-448(E)(2). | | | | | | 2. SATISFIED. SECTION 94-448 (D)(3) REQUIRES NATIVE | | | TREES IN GOOD CONDITION TO BE PRESERVED ON SITE OR | | | RELOCATED. ONCE ALL THE TREES AND PALMS ARE CORRECTLY | | | IDENTIFIED, THE NUMBER OF TREES AND PALMS REQUIRED TO | | | BE RELOCATED CAN BE DETERMINED. | | | THE APPLICANT WILL PROVIDE WRITTEN VERIFICATION FROM A | | | TREE RELOCATION CONTRACTOR IF THE LIVE OAK TREES #530, | | | #529 AND #535 AND SOUTHERN MAGNOLIA #538 LISTED IN GOOD | | | CONDITION CANNOT BE RELOCATED FOR ANY REASON. ANY | | | INFORMATION PROVIDED MUST BE IN REFERENCE TO ANSI A300 | | | (PART 5)-2005 STANDARDS ANNEX A. | | | | | | | | | | | | 3. SATISFIED. THE SITE DATA SHOWS THE LANDSCAPE AREA | | | FOR THE SITE WITH THE PROPOSED CHANGES BEING REDUCED TO | | | 11.5%. THIS IS BELOW THE REQUIRED 15% AND MUST BE | | | CORRECTED TO MEET THE CODE REQUIREMENTS TO BE APPROVED | | | AS A MINOR AMENDMENT. | | | 4. SATISFIED. PROPOSED LOCATIONS OF FPL TRANSFORMERS | | | AND SUPPLY LINES ALONG S DIXIE MAY NOT BE POSSIBLE TO | | | INSTALL WITHOUT DISTURBING EXISTING PALM TREES. ALSO, | | | LOCATIONS WILL LIMIT FUTURE OPTIONS FOR REQUIRED TREE | | | INSTALLATION. REVISE TO KEEP ALL EQUIPMENT OUTSIDE THE | | | REQUIRED 5 FOOT LANDSCAPE BUFFER. THIS AREA OF THE | | | BUFFER IS NON-CONFORMING AND SHOULD BE BROUGHT INTO | | | COMPLIANCE PROVIDING THE REQUIRED BUFFER TREES TO | | | PRODUCE SHADE FOR THE PUBLIC SIDEWALK. | | | 5. SATISFIED. HYDRANT AND OTHER VALVES ARE PROPOSED IN | | | LANDSCAPE ISLANDS ON THE ENGINEERING PLANS. REQUIRED | | | TREES MUST BE INSTALLED IN TERMINAL ISLANDS, SO | | | UTILITIES CANNOT BE LOCATED IN POSITIONS THAT WOULD | | | DISPLACE REQUIRED TREES. | | | 6. SATISFIED. THE LANDSCAPE AREAS IN THE PROPOSED | | | PARKING ARE DO NOT MEET THE REQUIREMENTS OF CODE | | | SECTION 94-443(C)(3) A. FOR THE REQUIRED SHADE OR | | | FLOWERING TREE. | | | 7. SATISFIED. THERE ARE LANDSCAPE ISLANDS SHOWN ON | | | SHEET LA-3 AND LA-7 THAT ARE NOT SHOWING REPLACEMENT OF | | | MISSING TREES. REVISE TO INCLUDE REPLACEMENTS. | | | 8. SATISFIED. SECTION 94-443(C)(3) REQUIRES THAT A | | | MINIMUM OF 75 PERCENT OF ALL TREES THAT ARE REQUIRED TO | | | BE PLANTED WITHIN THE INTERIOR OF AN OFF STREET PARKING | | | AREA SHALL BE CATEGORY 1 SHADE TREES. ROYAL PALMS DO | | | NOT MEET THE INTENT OF PROVIDING SHADE FOR PARKING | | | SPACES. | | | | | | 9. SATISFIED. SHOW LOCATIONS OF ANY ROOT BARRIERS | | | REQUIRED TO PROTECT UTILITY LINES. | | | | | | 10. SATISFIED. PROVIDE AN EXHIBIT SHOWING THE PARKING | | | AREA SURFACE CALCULATIONS, PARKING SPACE AREAS AND | | | LANDSCAPE AREAS PROVIDED TO DEMONSTRATE COMPLIANCE WITH | | | SECTIONS 94-443 (C)(3) AND (4). | | | | | | 11. SATISFIED. SHOW ALL REQUIRED CURBS ADJACENT TO | | | LANDSCAPE AREAS. THE AREA AT THE SOUTHEAST CORNER OF | | | THE PARKING DECK IS NOT DEFINED. | | | | | | 12. SATISFIED. PROVIDE THE AMOUNT OF LINEAR FEET OF | | | BUILDING PERIMETER LANDSCAPE PROPOSED TO MEET THE | | | REQUIREMENT OF 30% FOR COMMERCIAL USE FOR THE SOUTH | | | BUILDING. | | | | | | 13. SATISFIED. SHOW COMPLIANCE WITH SECTION 94-445 L. | | | PLANT SPECIES. A MINIMUM OF 60 PERCENT OF PLANT | | | MATERIAL ADDED SHALL BE FLORIDA NATIVE OR DROUGHT | | | TOLERANT SPECIES SELECTED FROM THE CITY LIST OR THE | | | LIST OF SPECIES IN THE MOST RECENT EDITION OF SOUTH | | | FLORIDA WATER MANAGEMENT DISTRICT WATERWISE SOUTH | | | FLORIDA LANDSCAPES. | | | PROVIDE THE ACTUAL PERCENTAGE OF DROUGHT TOLERANT AND | | | NATIVE SPECIES ADDED BASED ON THE PROPOSED PLANT LIST. | | | CHANGE ?REQUIRED? TO ?ADDED?. | | | | | | CONDITIONS OF APPROVAL | | | 1. PRIOR TO THE REMOVAL OR RELOCATION OF ANY TREES ON | | | THE PROPERTY, A TREE ALTERATION PERMIT SHALL BE | | | SUBMITTED, REVIEWED AND APPROVED BY THE DEVELOPMENT | | | SERVICES DEPARTMENT, PLANNING DIVISION. UPDATED TREE | | | DISPOSITION PLAN WITH CALCULATIONS FOR PAYMENT IN LIEU | | | IS TO BE SUBMITTED FOR TREE ALTERATION PERMIT | | | APPLICATION TP19-1778, AND PAYMENT SUBMITTED FOR THE | | | AMOUNT DUE WITHIN 10 DAYS OF THE APPROVAL OF THIS | | | PETITION. | | | | | | 2. THE APPLICANT, SUCCESSORS AND ASSIGNS SHALL BE | | | RESPONSIBLE FOR THE PERMITTING AND INSTALLATION OF THE | | | STREET TREES AND RIGHT OF WAY LANDSCAPING AND | | | IRRIGATION APPROVED WITH THIS PETITION. | | | 3. THE APPLICANT, SUCCESSORS AND ASSIGNS SHALL BE | | | RESPONSIBLE FOR THE MAINTENANCE OF THE ROAD RIGHT OF | | | WAY LANDSCAPING AND IRRIGATION. THIS WILL BE THROUGH A | | | SEPARATE MAINTENANCE AGREEMENT WITH THE CITY. | | | |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
3 |
Status |
F |
Date |
10-11-2019 |
|
|
Cont ID |
|
| Sent By |
rcaranci |
Date |
10-11-2019 |
Time |
16:17 |
Rev Time |
0.00 |
| Received By |
rcaranci |
Date |
10-11-2019 |
Time |
16:17 |
Sent To |
|
|
| Notes |
| 2019-10-11 16:17:57 | FROM: RAY CARANCI, LANDSCAPE PLANNER 561-822-1462 | | | PROJECT: SHOPS AT THE PRESS Z19050026 | | | OCTOBER 11, 2019 | | | I HAVE REVIEWED THE ABOVE REFERENCED PETITION, AND | | | PROVIDE THE FOLLOWING COMMENTS: | | | | | | 1. MAKE THE FOLLOWING CORRECTIONS TO THE TREE | | | DISPOSITION PLAN: | | | ? SATISFIED. IDENTIFY SPECIES OF ALL TREES AND PALMS ON | | | THE TREE DISPOSITION LIST. | | | ? SATISFIED. TREES AND PALMS CANOPY SQUARE FOOTAGE TO | | | BE MITIGATED BASED ON CATEGORY. ANY TREES 20 FEET OR | | | MORE CANOPY DIAMETER TO BE MITIGATED BY ACTUAL SQUARE | | | FOOTAGE. | | | ? SATISFIED. PROVIDE THE TOTAL SQUARE FOOTAGE OF | | | MITIGATION FOR ALL TREES AND PALMS PROPOSED TO BE | | | REMOVED. | | | ? PARTIALLY SATISFIED. PROVIDE THE REPLACEMENT | | | MITIGATION VALUES BY CATEGORY FOR THE PROPOSED TREES | | | AND PALMS. | | | THE CHART NECESSARY IS TO SHOW THE TOTAL SQUARE FOOTAGE | | | REQUIRED FOR MITIGATION BY ADDING ALL THE REMOVALS | | | TOGETHER. THE NEW TREES ADDED IN THE PLANT LIST ARE TO | | | BE GIVEN VALUES BY CATEGORY, THEN SUBTOTAL FOR EACH | | | SPECIES, THEN ADD THE TOTAL PROVIDED. STAFF | | | CALCULATIONS ARE 8971 SQ FT MITIGATION DUE, 4950 | | | PROVIDED NEW, AND TOTAL DIFFERENCE IS 4021 SQ FT TO | | | CALCULATE PAYMENT INTO TREE MITIGATION FUND. THIS COULD | | | BE REDUCED BY RELOCATING THE 2 LARGE LIVE OAK TREES. | | | RECALCULATE ALL MITIGATION DUE BASED ON COMMENT 2 | | | BELOW, AND IF PAYMENT IN LIEU IS REQUIRED, CALCULATE | | | THE AMOUNT DUE BY USING THE AVERAGE PRICE BY SPECIES | | | FOR A 12 FOOT GRADE ONE REPLACEMENT TREE AND MULTIPLY | | | BY TWO FOR INSTALLATION, PER SECTION 94-448(E)(2). | | | | | | 2. PARTIALLY SATISFIED. SECTION 94-448 (D)(3) REQUIRES | | | NATIVE TREES IN GOOD CONDITION TO BE PRESERVED ON SITE | | | OR RELOCATED. ONCE ALL THE TREES AND PALMS ARE | | | CORRECTLY IDENTIFIED, THE NUMBER OF TREES AND PALMS | | | REQUIRED TO BE RELOCATED CAN BE DETERMINED. | | | THE APPLICANT WILL PROVIDE WRITTEN VERIFICATION FROM A | | | TREE RELOCATION CONTRACTOR IF THE LIVE OAK TREES #530, | | | #529 AND #535 AND SOUTHERN MAGNOLIA #538 LISTED IN GOOD | | | CONDITION CANNOT BE RELOCATED FOR ANY REASON. ANY | | | INFORMATION PROVIDED MUST BE IN REFERENCE TO ANSI A300 | | | (PART 5)-2005 STANDARDS ANNEX A. | | | | | | | | | | | | 3. SATISFIED. THE SITE DATA SHOWS THE LANDSCAPE AREA | | | FOR THE SITE WITH THE PROPOSED CHANGES BEING REDUCED TO | | | 11.5%. THIS IS BELOW THE REQUIRED 15% AND MUST BE | | | CORRECTED TO MEET THE CODE REQUIREMENTS TO BE APPROVED | | | AS A MINOR AMENDMENT. | | | 4. SATISFIED. PROPOSED LOCATIONS OF FPL TRANSFORMERS | | | AND SUPPLY LINES ALONG S DIXIE MAY NOT BE POSSIBLE TO | | | INSTALL WITHOUT DISTURBING EXISTING PALM TREES. ALSO, | | | LOCATIONS WILL LIMIT FUTURE OPTIONS FOR REQUIRED TREE | | | INSTALLATION. REVISE TO KEEP ALL EQUIPMENT OUTSIDE THE | | | REQUIRED 5 FOOT LANDSCAPE BUFFER. THIS AREA OF THE | | | BUFFER IS NON-CONFORMING AND SHOULD BE BROUGHT INTO | | | COMPLIANCE PROVIDING THE REQUIRED BUFFER TREES TO | | | PRODUCE SHADE FOR THE PUBLIC SIDEWALK. | | | 5. SATISFIED. HYDRANT AND OTHER VALVES ARE PROPOSED IN | | | LANDSCAPE ISLANDS ON THE ENGINEERING PLANS. REQUIRED | | | TREES MUST BE INSTALLED IN TERMINAL ISLANDS, SO | | | UTILITIES CANNOT BE LOCATED IN POSITIONS THAT WOULD | | | DISPLACE REQUIRED TREES. | | | 6. SATISFIED. THE LANDSCAPE AREAS IN THE PROPOSED | | | PARKING ARE DO NOT MEET THE REQUIREMENTS OF CODE | | | SECTION 94-443(C)(3) A. FOR THE REQUIRED SHADE OR | | | FLOWERING TREE. | | | 7. SATISFIED. THERE ARE LANDSCAPE ISLANDS SHOWN ON | | | SHEET LA-3 AND LA-7 THAT ARE NOT SHOWING REPLACEMENT OF | | | MISSING TREES. REVISE TO INCLUDE REPLACEMENTS. | | | 8. SATISFIED. SECTION 94-443(C)(3) REQUIRES THAT A | | | MINIMUM OF 75 PERCENT OF ALL TREES THAT ARE REQUIRED TO | | | BE PLANTED WITHIN THE INTERIOR OF AN OFF STREET PARKING | | | AREA SHALL BE CATEGORY 1 SHADE TREES. ROYAL PALMS DO | | | NOT MEET THE INTENT OF PROVIDING SHADE FOR PARKING | | | SPACES. | | | | | | 9. SATISFIED. SHOW LOCATIONS OF ANY ROOT BARRIERS | | | REQUIRED TO PROTECT UTILITY LINES. | | | | | | 10. SATISFIED. PROVIDE AN EXHIBIT SHOWING THE PARKING | | | AREA SURFACE CALCULATIONS, PARKING SPACE AREAS AND | | | LANDSCAPE AREAS PROVIDED TO DEMONSTRATE COMPLIANCE WITH | | | SECTIONS 94-443 (C)(3) AND (4). | | | | | | 11. SATISFIED. SHOW ALL REQUIRED CURBS ADJACENT TO | | | LANDSCAPE AREAS. THE AREA AT THE SOUTHEAST CORNER OF | | | THE PARKING DECK IS NOT DEFINED. | | | | | | 12. SATISFIED. PROVIDE THE AMOUNT OF LINEAR FEET OF | | | BUILDING PERIMETER LANDSCAPE PROPOSED TO MEET THE | | | REQUIREMENT OF 30% FOR COMMERCIAL USE FOR THE SOUTH | | | BUILDING. | | | | | | 13. SATISFIED. SHOW COMPLIANCE WITH SECTION 94-445 L. | | | PLANT SPECIES. A MINIMUM OF 60 PERCENT OF PLANT | | | MATERIAL ADDED SHALL BE FLORIDA NATIVE OR DROUGHT | | | TOLERANT SPECIES SELECTED FROM THE CITY LIST OR THE | | | LIST OF SPECIES IN THE MOST RECENT EDITION OF SOUTH | | | FLORIDA WATER MANAGEMENT DISTRICT WATERWISE SOUTH | | | FLORIDA LANDSCAPES. | | | PROVIDE THE ACTUAL PERCENTAGE OF DROUGHT TOLERANT AND | | | NATIVE SPECIES ADDED BASED ON THE PROPOSED PLANT LIST. | | | CHANGE ?REQUIRED? TO ?ADDED?. | | | | | | CONDITIONS OF APPROVAL | | | 1. PRIOR TO THE REMOVAL OR RELOCATION OF ANY TREES ON | | | THE PROPERTY, A TREE ALTERATION PERMIT SHALL BE | | | SUBMITTED, REVIEWED AND APPROVED BY THE DEVELOPMENT | | | SERVICES DEPARTMENT, PLANNING DIVISION. | | | | | | 2. THE APPLICANT, SUCCESSORS AND ASSIGNS SHALL BE | | | RESPONSIBLE FOR THE PERMITTING AND INSTALLATION OF THE | | | STREET TREES AND RIGHT OF WAY LANDSCAPING AND | | | IRRIGATION APPROVED WITH THIS PETITION. | | | 3. THE APPLICANT, SUCCESSORS AND ASSIGNS SHALL BE | | | RESPONSIBLE FOR THE MAINTENANCE OF THE ROAD RIGHT OF | | | WAY LANDSCAPING AND IRRIGATION. THIS WILL BE THROUGH A | | | SEPARATE MAINTENANCE AGREEMENT WITH THE CITY. | | | |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
2 |
Status |
F |
Date |
08-15-2019 |
|
|
Cont ID |
|
| Sent By |
rcaranci |
Date |
08-15-2019 |
Time |
17:28 |
Rev Time |
0.00 |
| Received By |
rcaranci |
Date |
08-15-2019 |
Time |
17:27 |
Sent To |
|
|
| Notes |
| 2019-08-15 17:28:20 | FROM: RAY CARANCI, LANDSCAPE PLANNER 561-822-1462 | | | PROJECT: SHOPS AT THE PRESS Z19050026 | | | AUGUST 15, 2019 | | | I HAVE REVIEWED THE ABOVE REFERENCED PETITION, AND | | | PROVIDE THE FOLLOWING COMMENTS: | | | | | | 1. MAKE THE FOLLOWING CORRECTIONS TO THE TREE | | | DISPOSITION PLAN: | | | ? SATISFIED. IDENTIFY SPECIES OF ALL TREES AND PALMS ON | | | THE TREE DISPOSITION LIST. | | | ? PARTIALLY SATISFIED. TREES AND PALMS CANOPY SQUARE | | | FOOTAGE TO BE MITIGATED BASED ON CATEGORY. ANY TREES 20 | | | FEET OR MORE CANOPY DIAMETER TO BE MITIGATED BY ACTUAL | | | SQUARE FOOTAGE. | | | ? PARTIALLY SATISFIED. PROVIDE THE TOTAL SQUARE FOOTAGE | | | OF MITIGATION FOR ALL TREES AND PALMS PROPOSED TO BE | | | REMOVED. | | | ? PARTIALLY SATISFIED. PROVIDE THE REPLACEMENT | | | MITIGATION VALUES BY CATEGORY FOR THE PROPOSED TREES | | | AND PALMS. | | | THE CHART NECESSARY IS TO SHOW THE TOTAL SQUARE FOOTAGE | | | REQUIRED FOR MITIGATION BY ADDING ALL THE REMOVALS | | | TOGETHER. THE NEW TREES ADDED IN THE PLANT LIST ARE TO | | | BE GIVEN VALUES BY CATEGORY, THEN SUBTOTAL FOR EACH | | | SPECIES, THEN ADD THE TOTAL PROVIDED. STAFF | | | CALCULATIONS ARE 8971 SQ FT MITIGATION DUE, 4950 | | | PROVIDED NEW, AND TOTAL DIFFERENCE IS 4021 SQ FT TO | | | CALCULATE PAYMENT INTO TREE MITIGATION FUND. THIS COULD | | | BE REDUCED BY RELOCATING THE 2 LARGE LIVE OAK TREES. | | | | | | 2. SATISFIED. SECTION 94-448 (D)(3) REQUIRES NATIVE | | | TREES IN GOOD CONDITION TO BE PRESERVED ON SITE OR | | | RELOCATED. ONCE ALL THE TREES AND PALMS ARE CORRECTLY | | | IDENTIFIED, THE NUMBER OF TREES AND PALMS REQUIRED TO | | | BE RELOCATED CAN BE DETERMINED. | | | 3. SATISFIED. THE SITE DATA SHOWS THE LANDSCAPE AREA | | | FOR THE SITE WITH THE PROPOSED CHANGES BEING REDUCED TO | | | 11.5%. THIS IS BELOW THE REQUIRED 15% AND MUST BE | | | CORRECTED TO MEET THE CODE REQUIREMENTS TO BE APPROVED | | | AS A MINOR AMENDMENT. | | | 4. SATISFIED. PROPOSED LOCATIONS OF FPL TRANSFORMERS | | | AND SUPPLY LINES ALONG S DIXIE MAY NOT BE POSSIBLE TO | | | INSTALL WITHOUT DISTURBING EXISTING PALM TREES. ALSO, | | | LOCATIONS WILL LIMIT FUTURE OPTIONS FOR REQUIRED TREE | | | INSTALLATION. REVISE TO KEEP ALL EQUIPMENT OUTSIDE THE | | | REQUIRED 5 FOOT LANDSCAPE BUFFER. THIS AREA OF THE | | | BUFFER IS NON-CONFORMING AND SHOULD BE BROUGHT INTO | | | COMPLIANCE PROVIDING THE REQUIRED BUFFER TREES TO | | | PRODUCE SHADE FOR THE PUBLIC SIDEWALK. | | | 5. SATISFIED. HYDRANT AND OTHER VALVES ARE PROPOSED IN | | | LANDSCAPE ISLANDS ON THE ENGINEERING PLANS. REQUIRED | | | TREES MUST BE INSTALLED IN TERMINAL ISLANDS, SO | | | UTILITIES CANNOT BE LOCATED IN POSITIONS THAT WOULD | | | DISPLACE REQUIRED TREES. | | | 6. SATISFIED. THE LANDSCAPE AREAS IN THE PROPOSED | | | PARKING ARE DO NOT MEET THE REQUIREMENTS OF CODE | | | SECTION 94-443(C)(3) A. FOR THE REQUIRED SHADE OR | | | FLOWERING TREE. | | | 7. SATISFIED. THERE ARE LANDSCAPE ISLANDS SHOWN ON | | | SHEET LA-3 AND LA-7 THAT ARE NOT SHOWING REPLACEMENT OF | | | MISSING TREES. REVISE TO INCLUDE REPLACEMENTS. | | | 8. SATISFIED. SECTION 94-443(C)(3) REQUIRES THAT A | | | MINIMUM OF 75 PERCENT OF ALL TREES THAT ARE REQUIRED TO | | | BE PLANTED WITHIN THE INTERIOR OF AN OFF STREET PARKING | | | AREA SHALL BE CATEGORY 1 SHADE TREES. ROYAL PALMS DO | | | NOT MEET THE INTENT OF PROVIDING SHADE FOR PARKING | | | SPACES. | | | | | | 9. SATISFIED. SHOW LOCATIONS OF ANY ROOT BARRIERS | | | REQUIRED TO PROTECT UTILITY LINES. | | | | | | 10. SATISFIED. PROVIDE AN EXHIBIT SHOWING THE PARKING | | | AREA SURFACE CALCULATIONS, PARKING SPACE AREAS AND | | | LANDSCAPE AREAS PROVIDED TO DEMONSTRATE COMPLIANCE WITH | | | SECTIONS 94-443 (C)(3) AND (4). | | | | | | 11. SATISFIED. SHOW ALL REQUIRED CURBS ADJACENT TO | | | LANDSCAPE AREAS. THE AREA AT THE SOUTHEAST CORNER OF | | | THE PARKING DECK IS NOT DEFINED. | | | | | | 12. SATISFIED. PROVIDE THE AMOUNT OF LINEAR FEET OF | | | BUILDING PERIMETER LANDSCAPE PROPOSED TO MEET THE | | | REQUIREMENT OF 30% FOR COMMERCIAL USE FOR THE SOUTH | | | BUILDING. | | | | | | 13. PARTIALLY SATISFIED. SHOW COMPLIANCE WITH SECTION | | | 94-445 L. PLANT SPECIES. A MINIMUM OF 60 PERCENT OF | | | PLANT MATERIAL ADDED SHALL BE FLORIDA NATIVE OR DROUGHT | | | TOLERANT SPECIES SELECTED FROM THE CITY LIST OR THE | | | LIST OF SPECIES IN THE MOST RECENT EDITION OF SOUTH | | | FLORIDA WATER MANAGEMENT DISTRICT WATERWISE SOUTH | | | FLORIDA LANDSCAPES. | | | PROVIDE THE ACTUAL PERCENTAGE OF DROUGHT TOLERANT AND | | | NATIVE SPECIES ADDED BASED ON THE PROPOSED PLANT LIST. | | | CHANGE ?REQUIRED? TO ?ADDED?. | | | | | | CONDITIONS OF APPROVAL | | | 1. PRIOR TO THE REMOVAL OR RELOCATION OF ANY TREES ON | | | THE PROPERTY, A TREE ALTERATION PERMIT SHALL BE | | | SUBMITTED, REVIEWED AND APPROVED BY THE DEVELOPMENT | | | SERVICES DEPARTMENT, PLANNING DIVISION. | | | 2. THE APPLICANT, SUCCESSORS AND ASSIGNS SHALL BE | | | RESPONSIBLE FOR THE PERMITTING AND INSTALLATION OF THE | | | STREET TREES AND RIGHT OF WAY LANDSCAPING AND | | | IRRIGATION APPROVED WITH THIS PETITION. | | | 3. THE APPLICANT, SUCCESSORS AND ASSIGNS SHALL BE | | | RESPONSIBLE FOR THE MAINTENANCE OF THE ROAD RIGHT OF | | | WAY LANDSCAPING AND IRRIGATION. THIS WILL BE THROUGH A | | | SEPARATE MAINTENANCE AGREEMENT WITH THE CITY. | | | |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
1 |
Status |
F |
Date |
06-11-2019 |
|
|
Cont ID |
|
| Sent By |
rcaranci |
Date |
06-11-2019 |
Time |
15:56 |
Rev Time |
0.00 |
| Received By |
rcaranci |
Date |
06-11-2019 |
Time |
15:56 |
Sent To |
|
|
| Notes |
| 2019-06-11 15:56:44 | FROM: RAY CARANCI, LANDSCAPE PLANNER 561-822-1462 | | | PROJECT: SHOPS AT THE PRESS Z19050026 | | | JUNE 11, 2019 | | | I HAVE REVIEWED THE ABOVE REFERENCED PETITION, AND | | | PROVIDE THE FOLLOWING COMMENTS: | | | | | | 1. MAKE THE FOLLOWING CORRECTIONS TO THE TREE | | | DISPOSITION PLAN: | | | ? IDENTIFY SPECIES OF ALL TREES AND PALMS ON THE TREE | | | DISPOSITION LIST. | | | ? TREES AND PALMS CANOPY SQUARE FOOTAGE TO BE MITIGATED | | | BASED ON CATEGORY. ANY TREES 20 FEET OR MORE CANOPY | | | DIAMETER TO BE MITIGATED BY ACTUAL SQUARE FOOTAGE. | | | ? PROVIDE THE TOTAL SQUARE FOOTAGE OF MITIGATION FOR | | | ALL TREES AND PALMS PROPOSED TO BE REMOVED. | | | ? PROVIDE THE REPLACEMENT MITIGATION VALUES BY CATEGORY | | | FOR THE PROPOSED TREES AND PALMS. | | | | | | 2. SECTION 94-448 (D)(3) REQUIRES NATIVE TREES IN GOOD | | | CONDITION TO BE PRESERVED ON SITE OR RELOCATED. ONCE | | | ALL THE TREES AND PALMS ARE CORRECTLY IDENTIFIED, THE | | | NUMBER OF TREES AND PALMS REQUIRED TO BE RELOCATED CAN | | | BE DETERMINED. | | | 3. THE SITE DATA SHOWS THE LANDSCAPE AREA FOR THE SITE | | | WITH THE PROPOSED CHANGES BEING REDUCED TO 11.5%. THIS | | | IS BELOW THE REQUIRED 15% AND MUST BE CORRECTED TO MEET | | | THE CODE REQUIREMENTS TO BE APPROVED AS A MINOR | | | AMENDMENT. | | | 4. PROPOSED LOCATIONS OF FPL TRANSFORMERS AND SUPPLY | | | LINES ALONG S DIXIE MAY NOT BE POSSIBLE TO INSTALL | | | WITHOUT DISTURBING EXISTING PALM TREES. ALSO, LOCATIONS | | | WILL LIMIT FUTURE OPTIONS FOR REQUIRED TREE | | | INSTALLATION. REVISE TO KEEP ALL EQUIPMENT OUTSIDE THE | | | REQUIRED 5 FOOT LANDSCAPE BUFFER. THIS AREA OF THE | | | BUFFER IS NON-CONFORMING AND SHOULD BE BROUGHT INTO | | | COMPLIANCE PROVIDING THE REQUIRED BUFFER TREES TO | | | PRODUCE SHADE FOR THE PUBLIC SIDEWALK. | | | 5. HYDRANT AND OTHER VALVES ARE PROPOSED IN LANDSCAPE | | | ISLANDS ON THE ENGINEERING PLANS. REQUIRED TREES MUST | | | BE INSTALLED IN TERMINAL ISLANDS, SO UTILITIES CANNOT | | | BE LOCATED IN POSITIONS THAT WOULD DISPLACE REQUIRED | | | TREES. | | | 6. THE LANDSCAPE AREAS IN THE PROPOSED PARKING ARE DO | | | NOT MEET THE REQUIREMENTS OF CODE SECTION 94-443(C)(3) | | | A. FOR THE REQUIRED SHADE OR FLOWERING TREE. | | | 7. THERE ARE LANDSCAPE ISLANDS SHOWN ON SHEET LA-3 AND | | | LA-7 THAT ARE NOT SHOWING REPLACEMENT OF MISSING TREES. | | | REVISE TO INCLUDE REPLACEMENTS. | | | 8. SECTION 94-443(C)(3) REQUIRES THAT A MINIMUM OF 75 | | | PERCENT OF ALL TREES THAT ARE REQUIRED TO BE PLANTED | | | WITHIN THE INTERIOR OF AN OFF STREET PARKING AREA SHALL | | | BE CATEGORY 1 SHADE TREES. ROYAL PALMS DO NOT MEET THE | | | INTENT OF PROVIDING SHADE FOR PARKING SPACES. | | | | | | 9. SHOW LOCATIONS OF ANY ROOT BARRIERS REQUIRED TO | | | PROTECT UTILITY LINES. | | | | | | 10. PROVIDE AN EXHIBIT SHOWING THE PARKING AREA SURFACE | | | CALCULATIONS, PARKING SPACE AREAS AND LANDSCAPE AREAS | | | PROVIDED TO DEMONSTRATE COMPLIANCE WITH SECTIONS 94-443 | | | (C)(3) AND (4). | | | | | | 11. SHOW ALL REQUIRED CURBS ADJACENT TO LANDSCAPE | | | AREAS. THE AREA AT THE SOUTHEAST CORNER OF THE PARKING | | | DECK IS NOT DEFINED. | | | | | | 12. PROVIDE THE AMOUNT OF LINEAR FEET OF BUILDING | | | PERIMETER LANDSCAPE PROPOSED TO MEET THE REQUIREMENT OF | | | 30% FOR COMMERCIAL USE FOR THE SOUTH BUILDING. | | | | | | 13. SHOW COMPLIANCE WITH SECTION 94-445 L. PLANT | | | SPECIES. A MINIMUM OF 60 PERCENT OF PLANT MATERIAL | | | ADDED SHALL BE FLORIDA NATIVE OR DROUGHT TOLERANT | | | SPECIES SELECTED FROM THE CITY LIST OR THE LIST OF | | | SPECIES IN THE MOST RECENT EDITION OF SOUTH FLORIDA | | | WATER MANAGEMENT DISTRICT WATERWISE SOUTH FLORIDA | | | LANDSCAPES. | | | PROVIDE THE ACTUAL PERCENTAGE OF DROUGHT TOLERANT AND | | | NATIVE SPECIES ADDED BASED ON THE PROPOSED PLANT LIST. | | | | | | CONDITIONS OF APPROVAL | | | 1. PRIOR TO THE REMOVAL OR RELOCATION OF ANY TREES ON | | | THE PROPERTY, A TREE ALTERATION PERMIT SHALL BE | | | SUBMITTED, REVIEWED AND APPROVED BY THE DEVELOPMENT | | | SERVICES DEPARTMENT, PLANNING DIVISION. | | | 2. THE APPLICANT, SUCCESSORS AND ASSIGNS SHALL BE | | | RESPONSIBLE FOR THE PERMITTING AND INSTALLATION OF THE | | | STREET TREES AND RIGHT OF WAY LANDSCAPING AND | | | IRRIGATION APPROVED WITH THIS PETITION. | | | 3. THE APPLICANT, SUCCESSORS AND ASSIGNS SHALL BE | | | RESPONSIBLE FOR THE MAINTENANCE OF THE ROAD RIGHT OF | | | WAY LANDSCAPING AND IRRIGATION. THIS WILL BE THROUGH A | | | SEPARATE MAINTENANCE AGREEMENT WITH THE CITY. | | | |
|
|
| Review Stop |
PARK |
PARKING |
| Rev No |
1 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
|
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
POLICE |
POLICE |
| Rev No |
1 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
|
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
PW |
PUBLIC WORKS |
| Rev No |
3 |
Status |
P |
Date |
12-30-2019 |
|
|
Cont ID |
|
| Sent By |
|
Date |
12-30-2019 |
Time |
|
Rev Time |
0.00 |
| Received By |
|
Date |
12-30-2019 |
Time |
|
Sent To |
|
|
| Notes |
| 2019-12-30 10:54:14 | NO FURTHER COMMENTS FROM DEPT. OF PUBLIC WORKS. | | | | | | MATT HEJAZI | | | DEPT. OF PUBLIC WORKS | | | [email protected] | | | 561-822-2045 |
|
|
| Review Stop |
PW |
PUBLIC WORKS |
| Rev No |
2 |
Status |
F |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
10-07-2019 |
Time |
|
Rev Time |
0.00 |
| Received By |
|
Date |
10-07-2019 |
Time |
|
Sent To |
|
|
| Notes |
| 2019-10-07 16:10:22 | LOCATION OF THE DUMPSTER ENCLOSURE AS SHOWN ON SP-1 IS | | | TOO CLOSE TO THE LOADING ZONE, WHICH COULD CAUSE ISSUES | | | AND INTRUPTION TO THE SERVICE DUE TO BLOCKED ACCESS. | | | | | | MATT HEJAZI | | | DEPT. OF PUBLIC WORKS | | | [email protected] | | | 561-822-2045 |
|
|
| Review Stop |
PW |
PUBLIC WORKS |
| Rev No |
1 |
Status |
F |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
06-11-2019 |
Time |
|
Rev Time |
|
| Received By |
|
Date |
06-11-2019 |
Time |
|
Sent To |
|
|
| Notes |
| 2019-06-14 14:55:26 | PLEASE PROVIDE A PLAN SHOWING AUTO-TURN FOR SANITATION | | | SERVICE ALONG WITH THE DUMPTER ENCLOSURE SPEC. | | | | | | MATT HEJAZI | | | DEPT. OF PUBLIC WORKS | | | [email protected] | | | 561-822-2045 | | | |
|
|
| Review Stop |
STORM |
STORMWATER |
| Rev No |
2 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2019-10-09 09:05:57 | THE FOLLOWING COMMENT IS FROM THE REVIEW OF THE | | | 10/4/2019 REVIEW SET OF PLANS: | | | | | | 1. INDICATE HOW STORM WATER QUALITY TREATMENT IS BEING | | | PROVIDED FOR THE AREA OF NEW CONSTRUCTION. IF EXISTING | | | EXFILTRATION TRENCH IS BEING USED THEN A PROFESSIONAL | | | ENGINEER WILL NEED TO CERTIFY THE SYSTEM IS FUNCTIONING | | | PROPERLY. | | | | | | 2. SPECIAL PURPOSE SURVEY NOT INCLUDED IN THE SUBMITTAL | | | SO STAFF CANNOT DETERMINE IF PREVIOUS COMMENTS HAVE | | | BEEN ADDRESSED. | | | | | | TRACY WARD, PE | | | SENIOR STORMWATER ENGINEER | | | ENGINEERING SERVICES DEPARTMENT | | | 561-494-1120 | | | [email protected] | | | |
|
|
| Review Stop |
STORM |
STORMWATER |
| Rev No |
1 |
Status |
F |
Date |
06-10-2019 |
|
|
Cont ID |
|
| Sent By |
tward |
Date |
06-10-2019 |
Time |
18:51 |
Rev Time |
0.00 |
| Received By |
tward |
Date |
06-10-2019 |
Time |
18:52 |
Sent To |
|
|
| Notes |
| 2019-06-10 18:54:22 | THIS IS A CONCEPTUAL LEVEL REVIEW. CONSTRUCTION LEVEL | | | DETAILS, DESIGN CALCULATIONS AND THE POLLUTION | | | PREVENTION PLAN WILL BE REVIEWED AS PART OF THE | | | ENGINEERING DEVELOPMENT APPROVAL AND BUILDING PERMIT | | | APPLICATION PROCESSES. | | | THE ENGINEERING DEVELOPMENT APPROVAL APPLICATION FORMS | | | CAN BE DOWNLOADED AT | | | HTTP://WPB.ORG/DEPARTMENTS/ENGINEERING-PUBLIC-WORKS/FOR | | | MS,-PERMITS-APPLICATIONS | | | | | | THE FOLLOWING COMMENTS MUST BE ADDRESSED PRIOR TO SITE | | | PLAN APPROVAL: | | | | | | 1. PARKING STRUCTURE COLUMNS APPEAR TO BE BLOCKING USE | | | OF PROPOSED GROUND LEVEL PARKING SPACES. SOME OF THE | | | COLUMNS FOR THE DIAGONAL EDGE APPEAR TO BE IN THE DRIVE | | | AISLES. | | | | | | 2. WATER QUALITY TREATMENT AND PEAK FLOW ATTENUATION | | | MEETING SFWMD CRITERIA TO BE PROVIDED FOR THE AREA | | | IMPACTED BY CONSTRUCTION. | | | | | | 3. S. DIXIE HIGHWAY MAINTAINED BY FLORIDA DEPARTMENT OF | | | TRANSPORTATION. | | | | | | 4. ALTA/NSPS LAND TITLE SURVEY STATES PROPERTY IS | | | LOCATED IN A SPECIAL FLOOD HAZARD AREA. THIS IS | | | INCONSISTENT WITH BEING IN AN ?X-UNSHADED? AREA OF THE | | | FEMA FIRM. | | | | | | 5. VERIFY INVERT ELEVATION DIRECTIONS FOR THE DRAINAGE | | | STRUCTURES SHOWN ON THE SKETCH OF SPECIFIC PURPOSE | | | SURVEY. | | | | | | 6. THE CITY?S VERTICAL DATUM IS NGVD 1929. THE CITY HAS | | | ALLOWED THE USE OF NAVD 1988 PROVIDED THE CONVERSION | | | EQUATION TO NGVD 1929 IS PROVIDED ON THE SHEET(S). LIST | | | THE CONVERSION EQUATION ON THE SKETCH OF SPECIFIC | | | PURPOSE SURVEY. | | | | | | THE FOLLOWING COMMENTS MUST BE ADDRESSED PRIOR TO | | | ISSUANCE OF CONSTRUCTION AUTHORIZATION INCLUDING | | | BUILDING PERMITS AND ENGINEERING DEVELOPMENT APPROVAL. | | | | | | 1. AN ENGINEERING DEVELOPMENT APPROVAL APPLICATION MAY | | | BE REQUIRED FROM THE ENGINEERING SERVICES DEPARTMENT. | | | THE ENGINEERING DEVELOPMENT APPROVAL APPLICATION FORMS | | | CAN BE DOWNLOADED AT: HTTP://WPB.ORG/DEPARTMENTS/ENGINE | | | ERING-PUBLIC-WORKS/FORMS,-PERMITS-APPLICATIONS | | | | | | 2. EROSION CONTROL PLAN AND DETAILS TO BE SUBMITTED | | | WITH THE ENGINEERING PERMIT APPLICATION. | | | | | | 3. PROVIDE A COPY OF THE SFWMD ERP PRIOR TO STARTING | | | CONSTRUCTION. | | | | | | TRACY WARD, PE | | | SENIOR STORMWATER ENGINEER | | | ENGINEERING SERVICES DEPARTMENT | | | 561-494-1120 | | | [email protected] | | | |
|
|
| Review Stop |
SURVEY |
SURVEYING |
| Rev No |
2 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SURVEY |
SURVEYING |
| Rev No |
1 |
Status |
F |
Date |
06-10-2019 |
|
|
Cont ID |
|
| Sent By |
vnoel |
Date |
06-10-2019 |
Time |
13:37 |
Rev Time |
|
| Received By |
vnoel |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2019-06-10 13:51:08 | 1. AS PREVIOUSLY DISCUSSED, PROPERTY WILL NEED TO BE | | | REPLATTED. | | | 2. NEED TO SEE DETAIL OF FOOTINGS/IMPROVEMENTS IN | | | RELATION TO EXISTING WATER MAIN AND EASEMENT. | | | 3. OPTION TO EXTEND WATERMAIN ALONG WESTERLY PROPERTY | | | LINE SOUTH TO MONCEAUX IS BEING EXPLORED. | | | 4. VALVE WILL NEED TO BE INSTALLED PRIOR TO BRIDGE | | | DEMOLITION OVER WATER MAIN. |
|
|
| Review Stop |
TRAFFIC |
TRAFFIC ENGINEERING |
| Rev No |
3 |
Status |
P |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
01-15-2020 |
Time |
|
Rev Time |
0.00 |
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2020-01-15 10:25:52 | PASSED WITH CONDITION: | | | 1. DELIVERY TRUCKS SHALL BE LIMITED TO WB-40 SIZE AND | | | SHALL ACCESS THE LOADING AREA TO THE SOUTH OF THE | | | RENOVATED RETAIL/OFFICE BUILDING FROM DIXIE HIGHWAY, | | | TRAVELING WEST ON MONCEAUX ROAD AND CIRCULATING THROUGH | | | THE WEST PARKING LOT, TO ACCESS THE LOADING AREA. NO | | | ACCESS FROM GEORGIA AVENUE TO THE WEST, VIA MONCEAUX | | | AVENUE WILL BE PERMITTED. | | | | | | | | | | | | SHING TSOI | | | CITY IN-HOUSE TRAFFIC CONSULTANT | | | 561-494-1141 | | | [email protected] | | | (IN-HOUSE ON TUESDAYS AND WEDNESDAYS) |
|
|
| Review Stop |
TRAFFIC |
TRAFFIC ENGINEERING |
| Rev No |
2 |
Status |
F |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
08-19-2019 |
Time |
|
Rev Time |
0.00 |
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2019-08-19 16:21:50 | SITE PLAN COMMENTS: | | | 1. NO TRUCKS SHOULD USE GEORGIA AVENUE FOR DELIVERY. | | | ALL DELIVERY TRUCKS SHOULD ACCESS THE SITE THROUGH | | | DIXIE HIGHWAY AND THE PROPERTY PARKING LOT. | | | 2. PROVIDE AUTOTURN PATHS FOR ALL DELIVERY AND GARBAGE | | | TRUCKS ACCESS AND IN ALL LOADING ZONES, AS APPLICABLE. | | | TRUCKS IN THE LOADING ZONE AT THE NORTHWEST CORNER OF | | | THE SITE APPEAR TO BLOCK THE INTERNAL DRIVE AISLE. | | | ALSO, THE CITY CODE DOES NOT ALLOW FREIGHT VEHICLES TO | | | BACKUP INTO THE STREET OR TAKE THE SIDE STREETS AS THE | | | MAIN ROUTE. ALL TRUCK MANEUVERING SHOULD BE ON-SITE. | | | 3. SHOW PEDESTRIAN PATH BETWEEN DIXIE HIGHWAY AND THE | | | WESTERN HALF OF BUILDING 3. | | | 4. ILLUSTRATE THE ACCESSIBLE PATH FROM THE TWO | | | HANDICAPPED PARKING SPACES WEST OF BUILDING 1 TO THE | | | BUILDING ENTRANCE. | | | TRAFFIC STUDY COMMENTS: | | | 5. CLARIFY THE CALCULATION OF THE 10% REDEVELOPMENT | | | CREDIT. IN THE LATEST SUBMITTAL, ONLY 29,022 SF OF | | | WAREHOUSE IS REDEVELOPED INTO A GROCERY STORE, BUT THE | | | REDEVELOPMENT CREDIT ASSUMED FOR PHASE 1 IS THE SAME AS | | | THE FULL REDEVELOPMENT. 86,650 SF OF OFFICE IS | | | DEMOLISHED AND CONVERTED TO PARKING. THE REMAINING | | | OFFICE AND WAREHOUSE USES WOULD REMAIN IN THE EXISTING | | | BUILDINGS. | | | 6. THE TRAFFIC STUDY SHOWS THE FULL REDEVELOPMENT WHICH | | | GENERATE 1,976 NET NEW DAILY TRIPS AND 158 NET NEW PM | | | TRIPS. IF THE DEVELOPER DOES NOT PROPOSE TO IMPLEMENT | | | THE OFF-SITE IMPROVEMENTS TO MITIGATE TRAFFIC IMPACT OF | | | THE FULL REDEVELOPMENT IN THIS MINOR AMENDMENT, PLEASE | | | SUBMIT A SEPARATE TRAFFIC STATEMENT OR LETTER SIGNED BY | | | A PE DOCUMENTING TRIP GENERATION FOR ONLY PHASE 1 OF | | | THE DEVELOPMENT. THE FULL TRAFFIC STUDY WILL BE | | | REVIEWED IN DETAIL WHEN MAJOR AMENDMENT APPLICATION IS | | | SUBMITTED, AND WILL BE SUBJECT TO THE CITY'S TRAFFIC | | | STUDY REQUIREMENTS AT THE TIME OF SUBMISSION. | | | | | | LINA M. CAMACHO | | | SENIOR PROJECT ENGINEER | | | 561-494-1129 | | | [email protected] | | | |
|
|
| Review Stop |
TRAFFIC |
TRAFFIC ENGINEERING |
| Rev No |
1 |
Status |
F |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
06-11-2019 |
Time |
|
Rev Time |
|
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2019-06-11 18:07:23 | 1. PROVIDE THE COUNTY TPS LETTER | | | 2. THE CITY CODE DOES NOT ALLOW A FREIGHT VEHICLES TO | | | BACKUP INTO THE STREET OR TAKE THE SIDE STREETS AS THE | | | MAIN ROUTE. PROVIDE FREIGHT VEHICLE CIRCULATION AND A | | | MANAGE PLAN TO PREVENT THE INTRUSION INTO THE SIDE | | | STREETS. | | | 3. PROVIDE PEDESTRIAN CROSSING AT THE RAILROAD TRACKS | | | FROM THE EXISTING WEST PARKING LOT INTO THE PROPOSED | | | BUILDING 3. | | | 4. PROVIDE A BUS SHELTER. | | | 5. PROVIDE MEDIAN OR QUAD GATES FOR SAFETY AT MONCEAUX | | | RD AND THE RAILROAD TRACK CROSSING. | | | 6. MILL AND RESURFACE MONCEAUX RD FROM S. DIXIE HWY TO | | | FLORIDA AVE. | | | 7. MONCEAUX RD IS PART OF THE CITY?S BICYCLE | | | MASTERPLAN. PROVIDE BIKE LANES AT BOTH SIDES OF | | | MONCEAUX RD FROM S. DIXIE HWY TO FLORIDA AVE. | | | | | | | | | LINA M. CAMACHO | | | SENIOR PROJECT ENGINEER | | | 561-494-1129 | | | [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
F |
Date |
01-13-2020 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
01-13-2020 |
Time |
14:19 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
01-13-2020 |
Time |
14:19 |
Sent To |
|
|
| Notes |
| 2020-01-13 14:20:14 | PLANS AND PLATS REVIEW COMMITTEE (PPRC) ZONING REVIEW | | | ________________________________________ | | | | | | DATE OF REVIEW: 01.13.2020 | | | PROJECT NO.: Z19050026 | | | CASE NO.: PB 1086B | | | ________________________________________ | | | | | | PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING | | | REVIEW COMMENTS: | | | | | | 1. [ SATISFIED ] - UTILITY LETTERS SHALL BE PROVIDED | | | INDICATING NO OBJECTION TO THE PROPOSED IMPROVEMENTS. | | | | | | 1.1. [ SATISFIED ] - LETTERS FROM FPL AND AT&T SHALL BE | | | PROVIDED. | | | | | | 2. [ SATISFIED ] - THE SITE PLAN IS UNCLEAR AS TO WHAT | | | IMPROVEMENTS ARE EXISTING AND WHICH ONES ARE PROPOSED. | | | AS SUCH, IT IS DIFFICULT TO DETERMINE WHAT IS | | | NONCONFORMING AND MAY NEED TO BE BROUGHT INTO | | | COMPLIANCE, ETC. | | | | | | 2.1. [ SATISFIED ] - THERE APPEARS TO BE A NUMBER OF | | | IMPROVEMENTS TO THE WEST OF, AND UNDERNEATH, THE | | | EXISTING OFFICE BUILDING THAT ARE NOT SHOWN AS BEING | | | INCLUDED IN THE ?AFFECTED AREA?. THE IMPROVEMENTS | | | INCLUDE THE ADDITION OF BICYCLE PARKING, A DUMPSTER | | | ENCLOSURE, TERMINATION OF THE PARKING DRIVE AISLE | | | UNDERNEATH THE BUILDING DUE TO THE RAMP FOR THE PARKING | | | DECK, ETC. PLEASE NOTE THAT THERE ARE NEW COMMENTS | | | PROVIDED THAT RELATE TO ADDITIONAL CONCERNS WITH THESE | | | ITEMS. | | | | | | 3. [ PARTIALLY SATISFIED ] - AS A FOLLOW UP TO PREVIOUS | | | DISCUSSIONS, WHAT IS THE LATEST REGARDING THE DESIGN OF | | | THE FUTURE GROCER AND THE ACTIVATION OF THE SOUTH DIXIE | | | HIGHWAY CORRIDOR? | | | | | | 3.1. [ SATISFIED ] - A SMALL OUTDOOR SEATING AREA WAS | | | ADDED TO THE ARCHITECTURAL PLANS, BUT THIS IS NOT SHOWN | | | ON THE SITE OR LANDSCAPE PLANS. ADDITIONALLY, IT IS | | | UNCLEAR HOW THIS SEATING AREA CAN BE ACCESSED. | | | | | | 4. [ SATISFIED ] - THE SITE PLAN IS UNCLEAR AS TO THE | | | LOCATION OF THE RAMP THAT PROVIDES ACCESS TO THE TOP OF | | | THE PARKING DECK. IT SEEMS THAT THE RAMP MAY IMPEDE | | | WITH MULTIPLE DRIVE AISLES AND OVERALL SITE | | | CIRCULATION, IMPACTING EXISTING PARKING. | | | | | | 5. [ SATISFIED ] - THE PROPOSED PARKING DECK APPEARS TO | | | CONFLICT WITH MULTIPLE UTILITY LINES, ESPECIALLY A | | | WATER MAIN LOCATED WITHIN A 10-FOOT EASEMENT AND A SIX | | | (6) FOOT UNDERGROUND UTILITY EASEMENT. | | | | | | 5.1. [ SATISFIED ] - A PORTION OF THE PARKING DECK | | | (NORTHEAST CORNER) STILL EXTENDS INTO THE SIX (6) FOOT | | | UNDERGROUND UTILITY EASEMENT. | | | | | | 5.1.1. [ CONDITION OF APPROVAL ] ? EASEMENT WILL NEED | | | TO BE ABANDONED PRIOR TO PERMITTING. | | | | | | 5.2. [ CONDITION OF APPROVAL ] - THE SITE PLAN SHOWS A | | | PROPOSED 10-FOOT WATER EASEMENT, BUT WHAT IS PROPOSED | | | TO HAPPEN WITH THE EXISTING EASEMENT THAT IS SHOWN | | | UNDER THE PROPOSED PARKING DECK? THE ENGINEERING PLANS | | | INDICATE THAT THIS IS GOING TO BE ABANDONED. IF SO, THE | | | UTILITY WORK, AND MODIFICATIONS TO THE EASEMENT WILL BE | | | REQUIRED PRIOR TO ISSUANCE OF ANY PERMITS FOR THE | | | PARKING DECK. | | | | | | 5.3. [ NEW COMMENT ] - A NUMBER OF IMPROVEMENTS ARE | | | SHOWN IN THE 12-FOOT FPL EASEMENT IMMEDIATELY NORTH OF | | | THE WAREHOUSE BUILDING. | | | | | | 5.3.1. [ CONDITION OF APPROVAL ] ? EASEMENT WILL NEED | | | TO BE ABANDONED PRIOR TO PERMITTING. | | | | | | 5.4. [ SATISFIED ] - A NUMBER OF IMPROVEMENTS ARE SHOWN | | | IN THE FPL EASEMENT WEST OF THE EXISTING OFFICE | | | BUILDING. | | | | | | 6. [ SATISFIED ] - THE PARKING DECK SHOULD BE ADDED | | | INTO THE SITE DATA TABLE FOR ALL APPLICABLE | | | CALCULATIONS (LOT COVERAGE, IMPERVIOUS, BUILDING | | | SETBACKS, BUILDING HEIGHT, ETC.). IT IS REQUIRED TO | | | COMPLY WITH THE SAME REGULATIONS AS OTHER BUILDINGS IN | | | THE GENERAL COMMERCIAL (GC) ZONING DISTRICT. | | | | | | 7. [ SATISFIED ] - PURSUANT TO SEC. 94-145(7), THE | | | MINIMUM BUILDING SEPARATION SHALL BE ZERO FEET, OR NOT | | | LESS THAN TEN (10) FEET. ACCORDING TO THE SITE PLAN, | | | THE PARKING DECK IS ONLY 4.5 FEET FROM THE EXISTING | | | OFFICE BUILDING. | | | | | | 8. [ SATISFIED ] - BY DEFINITION, THE FRONT OF THE | | | PROPERTY IS ALONG BELVEDERE ROAD AND MONCEAUX ROAD; | | | SOUTH DIXIE HIGHWAY IS CONSIDERED A CORNER-SIDE. | | | | | | 9. [ PARTIALLY SATISFIED - SEE CONDITION OF APPROVAL | | | BELOW ] - IN DISCUSSION AMONGST STAFF, IT WAS SUGGESTED | | | THAT SINCE A LINER BUILDING IS NOT BEING PROPOSED ALONG | | | SOUTH DIXIE (IN FRONT OF THE PARKING DECK, ETC.) THAT | | | SOME ARCHITECTURAL ELEMENTS OR DECORATIVE FEATURES | | | (SUCH AS A TRELLIS, ETC.) COULD BE INCORPORATED INTO, | | | OR IN PLACE OF, THE EASTERN MOST ROW OF PARKING. | | | | | | 9.1. [ NOT SATISFIED ] - WHAT WAS THE OBJECTION TO THE | | | INSTALLATION OF A TRELLIS, ETC.? | | | | | | 9.1.1. [ NEW COMMENT ] ? RESPONSE INDICATED THAT THIS | | | WAS GOING TO BE FURTHER EXPLORED AS PART OF THE MAJOR | | | AMENDMENT, BUT NOTHING HAS BEEN PROVIDED WITHIN THAT | | | APPLICATION. | | | | | | 9.2. [ CONDITION OF APPROVAL ] - THE PROVISION OF BUS | | | SHELTER AND THE DESIGN OF SUCH SHALL BE INCLUDED AS | | | PART OF THE FUTURE MAJOR AMENDMENT. | | | | | | 10. [ SATISFIED ] - THERE SEEMS TO BE A LARGE NUMBER OF | | | SMALL CAR SPACES CONCENTRATED IN SOME OF THE AREA WHERE | | | PARKING DEMAND WILL BE HEAVIEST. PURSUANT TO SEC. | | | 94-485(N)(1)E., SMALL CAR SPACES ARE TO BE DISTRIBUTED. | | | | | | 11. [ SATISFIED ] - YOU WILL NEED TO CONFIRM WITH THE | | | BUILDING DIVISION, BUT ACCESSIBLE PARKING MAY NEED TO | | | BE PROVIDED UNDER THE COVER OF THE PARKING DECK. | | | | | | 12. [ SATISFIED - SEE CONDITION OF APPROVAL BELOW ] - | | | THE SQUARE FOOTAGES IN THE TRAFFIC ANALYSIS AND PBC | | | TRAFFIC CONCURRENCY DETERMINATION DO NOT SEEM TO | | | CORRESPOND WITH THE SQUARE FOOTAGES THAT ARE SHOWN ON | | | THE SITE PLAN. PLEASE ENSURE THAT ALL PLANS, STUDIES, | | | ETC. ARE CONSISTENT. | | | | | | 12.1. [ CONDITION OF APPROVAL ] - A CONDITION OF | | | APPROVAL WILL EXIST REGARDING THE MAXIMUM SQUARE | | | FOOTAGE THAT CAN BE OCCUPIED, AND THAT THE TRAFFIC | | | ANALYSIS AND CONCURRENCY DETERMINATION BE UPDATED AS | | | PART OF FUTURE DEVELOPMENT. | | | | | | 13. [ SATISFIED - SEE CONDITION OF APPROVAL BELOW ] - | | | THE TRAFFIC CONCURRENCY DETERMINATION LETTER FROM PALM | | | BEACH COUNTY INDICATES THAT THE PROJECT IS TO ?MEET | | | CRITERIA AS OUTLINED IN THE CITY?S TDM (TRANSPORTATION | | | DEMAND MANAGEMENT) ORDINANCE.? PLEASE PROVIDE DETAILS | | | AS THERE IS NO TDM ORDINANCE THAT HAS BEEN ADOPTED FOR | | | THIS AREA. | | | | | | 13.1. [ CONDITION OF APPROVAL ] - A CONDITION OF | | | APPROVAL WILL EXIST REGARDING THE MAXIMUM SQUARE | | | FOOTAGE THAT CAN BE OCCUPIED. | | | | | | 14. [ SATISFIED ] - THE TRAFFIC IMPACT ANALYSIS | | | REFERENCES THAT THE PROJECT WILL BE PARTICIPATING IN | | | THE CITY?S MOBILITY FUNDS PROGRAM; PLEASE NOTE THAT NO | | | SUCH PROGRAM HAS BEEN ADOPTED, AND UNDER THE ?PROPOSED? | | | PROGRAM, THE SUBJECT PROPERTY IS OUTSIDE THE BOUNDARIES | | | OF SUCH PROGRAM. | | | | | | 14.1. [ SATISFIED ] - THE TRAFFIC IMPACT ANALYSIS | | | SHOULD HAVEN BEEN REVISED TO REMOVE REFERENCE TO THE | | | MOBILITY FUND AND TDM PROGRAM. | | | | | | 15. [ SATISFIED ] - PURSUANT TO THE PBC TRAFFIC | | | CONCURRENCY DETERMINATION LETTER, AN FDOT CONCEPTUAL | | | DRIVEWAY PRE-APPROVAL LETTER SHALL BE OBTAINED. SPECIAL | | | ATTENTION SHOULD BE PROVIDED REGARDING THE COUNTY?S | | | SUGGESTION OF A CENTER LEFT TURN LANE. | | | | | | 15.1. [ SATISFIED ] - THE LETTER FROM FDOT INDICATES | | | THAT ALL OF THE DRIVEWAYS ARE RIGHT IN/RIGHT OUT, BUT | | | THE STRIPING AND DESIGN SHOWN ON THE SITE PLAN DOES NOT | | | INDICATE SUCH. | | | | | | 16. [ SATISFIED ] - SIDEWALKS/CROSSINGS SHALL BE | | | PROVIDED FROM THE PEDESTRIAN EXIT POINTS OF THE PARKING | | | DECK TO BUILDINGS #1 AND #3. | | | | | | 16.1. [ SATISFIED ] - THERE?S CONCERN REGARDING THE | | | DESIGN OF THE CROSSWALK, STOP SIGN, ETC. THAT IS | | | PROPOSED IN THE SOUTHWEST CORNER OF THE PARKING DECK. | | | THE STOP SIGN APPEARS TO BE FLOATING IN THE DRIVE | | | AISLE, PEDESTRIANS ARE DIRECTED TO WALK IN FRONT OF | | | VEHICLES BEFORE CROSSING THE DRIVEWAY, ETC. THE | | | ISLAND/LANDING AT THE BASE OF THE STAIRS SHOULD BE | | | EXTENDED TO THE EDGE OF THE DRIVE AISLE, ALLOWING FOR | | | PLACEMENT OF THE STOP SIGN, AND THE CROSS WALK CAN GO | | | FROM THE SOUTH EDGE OF THE LANDING. | | | | | | 17. [ SATISFIED - SEE CONDITION OF APPROVAL BELOW ] - | | | SIGNAGE SHOULD BE REMOVED FROM THE ARCHITECTURAL | | | DRAWINGS AND SHOULD BE REVIEWED AS A SEPARATE SIGN | | | PACKAGE. | | | | | | 17.1. [ CONDITION OF APPROVAL ] - ALL SIGNAGE WILL BE | | | REVIEWED AT THE TIME OF PERMITTING AND SHALL COMPLY | | | WITH THE ZLDRS. | | | | | | 18. [ SATISFIED - SEE CONDITION OF APPROVAL BELOW ] - | | | ADDITIONAL INFORMATION WILL NEED TO BE PROVIDED FOR | | | REVIEW OF THE FREESTANDING SIGNS: | | | | | | 18.1. [ SATISFIED - SEE CONDITION OF APPROVAL BELOW ] - | | | SETBACK SHALL BE PROVIDED FROM ALL FREESTANDING SIGNS | | | TO THE ADJACENT PROPERTY LINE, AND SHALL COMPLY WITH | | | THE APPLICABLE PROVISIONS OF SEC. 94-408(D)(2) AND (3). | | | | | | 18.2. [ SATISFIED - SEE CONDITION OF APPROVAL BELOW ] - | | | SQUARE FOOTAGE OF FREESTANDING SIGN AREA SHALL BE | | | PROVIDED AND SHALL COMPLY WITH THE APPLICABLE | | | PROVISIONS OF SEC. 94-408(D)(2) AND (3). | | | | | | 18.3. [ CONDITION OF APPROVAL ] - ALL SIGNAGE WILL BE | | | REVIEWED AT THE TIME OF PERMITTING AND SHALL COMPLY | | | WITH THE ZLDRS. | | | | | | 19. [ NOT SATISFIED ] - SCREENING SHALL BE PROVIDED FOR | | | THE TRASH COMPACTOR IN ACCORDANCE WITH SEC. 94-315(A). | | | | | | 19.1. [ NOT SATISFIED ] - STAFF DOES NOT UNDERSTAND THE | | | RESPONSE THAT WAS PROVIDED. PLEASE CLARIFY HOW THE | | | TRASH COMPACTOR IS PROPOSED TO COMPLY WITH THE CITED | | | PROVISION OF THE CITY?S ZLDRS. | | | | | | 19.1.1. [ NEW COMMENT ] ? THE SITE HAS A LABEL FOR A | | | TRASH COMPACTOR, BUT NOTHING IS SHOWN ON THE SITE | | | PLAN?NO ENCLOSURE, NO LANDSCAPE SCREENING, ETC. AS | | | SHOWN ON THE PLAN IT LOOKS LIKE THE TRASH COMPACTOR | | | WOULD JUST BE SITTING IN THE MIDDLE OF THE LOADING | | | AREA. | | | | | | 20. [ SATISFIED ] - IT IS STAFF'S POSITION THAT | | | LANDSCAPING SHALL BE PROVIDED ALONG THE OUTER PERIMETER | | | OF THE PARKING DECK (SPECIFICALLY THE EAST AND SOUTH | | | SIDES) TO SOFTEN THE APPEARANCE OF THE STRUCTURE AND | | | MAKE IT BLEND IN WITH THE REMAINDER OF THE SITE. | | | | | | 21. [ SATISFIED ] - MULTIPLE STRUCTURAL COLUMNS FOR THE | | | PARKING DECK ENCROACH INTO DRIVE AISLES, PARKING | | | SPACES, ETC. ON THE GROUND LEVEL. | | | | | | 21.1. [ SATISFIED ] - PLEASE CONFIRM THAT NO COLUMNS | | | ARE PROPOSED ON THE INTERIOR (GROUND LEVEL) OF THE | | | PARKING DECK. IF COLUMNS ARE PROPOSED, THEY SHALL BE | | | SHOWN ON THE PLAN TO INDICATE THAT THEY DO NOT CONFLICT | | | WITH PARKING SPACES OR DRIVE AISLES AND/OR THAT THE | | | STRIPING IS ADJUSTED ACCORDINGLY TO ACCOMMODATE THEM. | | | | | | 22. [ SATISFIED ] - THE PARKING STALL DETAIL ON SHEET | | | 12 OF THE ENGINEERING PLANS SHALL CONFORM TO THE CITY?S | | | MINIMUM REQUIREMENTS. | | | | | | 23. [ SATISFIED ] - THE BICYCLE PARKING DETAIL | | | REFERENCES THE SITE PLAN FOR DIMENSIONS, ETC., BUT NO | | | DIMENSIONS WERE PROVIDED. | | | | | | 24. [ SATISFIED ] - BICYCLE PARKING NEEDS TO BE | | | DISTRIBUTED THROUGHOUT THE SITE BASED UPON THE USES ON | | | THE PROPERTY, AND SHALL BE SITUATED IN PROXIMITY TO | | | BUILDING ENTRANCE, ETC. SO AS TO BE VISIBLE TO PATRONS. | | | THE LOCATION OF THE BICYCLE PARKING FOR BUILDING #1 IS | | | OF GREATEST CONCERN. | | | | | | 25. [ SATISFIED] - WITH THE CREATION OF THE DEAD-END | | | DRIVE AISLE UNDERNEATH THE EXISTING OFFICE BUILDING, A | | | TURN-AROUND SPACE SHALL BE PROVIDED. | | | | | | 26. [ NOT SATISFIED ] - WITH THE CREATION OF THE | | | DEAD-END DRIVE AISLE UNDERNEATH THE PROPOSED PARKING | | | DECK, A TURN-AROUND SPACE SHALL BE PROVIDED. | | | | | | 27. [ PARTIALLY SATISFIED ] - THE BICYCLE PARKING | | | PROVIDED WEST OF THE EXISTING OFFICE BUILDING APPEARS | | | TO BE ENCROACHING INTO THE DRIVE AISLE AND COULD EASILY | | | BE DAMAGED BY PASSING VEHICLES, ETC. | | | | | | 27.1. [ NEW COMMENT ] ? STAFF DOES NOT LIKE HOW THE | | | PROPOSED BIKE RACKS ARE BEING INSTALLED AT THE SAME | | | GRADE AS THE SURROUNDING PARKING/LOADING AREA. THE BIKE | | | RACK AREA SHOULD BE RAISED ABOVE THE LEVEL OF THE | | | PARKING AND PROTECTED WITH CURBING, ETC. | | | | | | 28. [ SATISFIED ] - LANDSCAPING AROUND THE BASE OF THE | | | ENCLOSURE IS REQUIRED. | | | | | | 29. [ PARTIALLY SATISFIED ] - PLEASE CLARIFY THE DESIGN | | | PROPOSED IMMEDIATELY NORTH OF THE WAREHOUSE BUILDING. | | | IS CURBING PROPOSED BETWEEN THE DRIVEWAY AND THE FRONT | | | ENTRANCE? IF NOT, AND THE DRIVEWAY IS AT THE SAME | | | ELEVATION AS THE ENTRY, SOME FORM OF | | | PEDESTRIAN-FRIENDLY BARRIER SHOULD BE CONSIDERED TO | | | KEEP VEHICLES FROM ENCROACHING INTO THE PEDESTRIAN | | | AREA. | | | | | | 29.1. [ NEW COMMENT ] ? THE SITE PLAN HAS BECOME | | | EXTREMELY UNCLEAR AS TO WHAT EACH LINE TYPE, THICKNESS, | | | ETC. REPRESENTS. | | | | | | 30. [ SATISFIED ] - THERE IS A LARGE AMOUNT OF UTILITY | | | EQUIPMENT (WATER METERS, BACKFLOW, ETC.) IMMEDIATELY IN | | | FRONT OF THE PROPOSED GROCER; SUCH EQUIPMENT NEEDS TO | | | BE SCREENED. | | | | | | 31. [ SATISFIED ] - THE SITE AND LANDSCAPE PLANS SHOW A | | | DOOR EXITING THE FRONT OF THE GROCER WITH A SET OF | | | STAIRS LEADING DOWN. PLEASE CLARIFY AS THIS IS NOT | | | SHOWN ON ANY OTHER PLAN. | | | | | | 32. [ SATISFIED ] - ON THE ENGINEERING PLANS IT APPEARS | | | THAT THERE IS NOT SUFFICIENT CLEAR WIDTH BETWEEN THE | | | HANDICAP PARKING SIGNS, CAUSING THIS ROUTE TO NOT BE | | | ADA COMPLIANT. PLEASE VERIFY. | | | | | | 33. [ SATISFIED ] - ON THE SITE PLAN, THE DETAIL FOR | | | THE SECOND LEVEL OF THE PARKING DECK HAS A LABEL FOR A | | | TYPICAL LIGHT POLE THAT IS PLACED INCORRECTLY. | | | | | | 34. [ NEW COMMENT ] ? THE CONFIGURATION OF THE DUMPSTER | | | TO THE NORTHWEST OF BUILDING #1 DIFFERS FROM THAT WHICH | | | WAS SHOWN ON THE MAJOR AMENDMENT. ENSURE THAT ALL PLANS | | | ARE CONSISTENT. | | | | | | 35. [ NEW COMMENT ] - THE TURNING MOVEMENTS SHOWN ON | | | THE SITE PLAN FOR THE DUMPSTER TO THE NORTHWEST OF | | | BUILDING #1 ONLYS SHOW THE TRUCK MOVEMENTS ENTERING TO | | | PICK UP THE DUMPSTER; NO MOVEMENTS ARE SHOWN ON HOW THE | | | TRUCK IS EXITING THE SITE. | | | | | | 36. [ NEW COMMENT ] ? THE PEDESTRIAN CROSSING AT THE | | | SOUTHEAST CORNER OF BUILDING #1 LEADS INTO A LANDSCAPE | | | AREA; NO RAMP, SIDEWALK, ETC. IS SHOWN TO CONNECT THIS | | | CROSSING TO THE SIDEWALK TO THE EAST OF BUILDING #1. | | | ________________________________________ | | | | | | PLEASE NOTE THE FOLLOWING WHEN RESUBMITTING: | | | | | | A) WRITTEN RESPONSES TO COMMENTS MADE BY ALL | | | DEPARTMENTS SHALL BE PROVIDED UPON RESUBMISSION. | | | | | | B) FOUR (4) SETS OF REVISED PLANS AND/OR DOCUMENTS | | | SHALL BE PROVIDED, ALONG WITH ONE (1) REDUCED COPY | | | (11IN X 17IN), AND AN ELECTRONIC COPY OF ALL PLANS. | | | | | | C) PLEASE NOTE THAT RE-SUBMITTALS MAY BE SUBJECT TO | | | ADDITIONAL COMMENTS. | | | | | | D) IF NO RESPONSE IS RECEIVED WITHIN 60 DAYS OF THE | | | ISSUANCE OF THESE COMMENTS, THE APPLICATION WILL BE | | | CONSIDERED WITHDRAWN AND ANY FURTHER ACTION WILL | | | REQUIRE SUBMISSION OF A NEW DEVELOPMENT APPLICATION. | | | | | | E) PLEASE NOTE THAT YOU WILL BE PERMITTED ONE (1) | | | RESUBMITTAL AT NO ADDITIONAL COST. IF PREVIOUSLY-ISSUED | | | COMMENTS CONTINUE TO NOT BE SUFFICIENTLY ADDRESSED, THE | | | APPLICANT WILL BE ACCESSED A RESUBMITTAL FEE. SUCH FEE | | | WILL BE 20% OF THE ORIGINAL APPLICATION FEE. | | | ________________________________________ | | | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | | | JOHN P. ROACH, AICP, PRINCIPAL PLANNER | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION | | | 401 CLEMATIS STREET - P.O. BOX 3147 | | | WEST PALM BEACH, FLORIDA 33402 | | | | | | P: 561.822.1448 | | | TTY: 800.955.8771 | | | E: [email protected] | | | | | | W: WPB.ORG | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
09-06-2019 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
09-06-2019 |
Time |
09:39 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
09-05-2019 |
Time |
15:12 |
Sent To |
|
|
| Notes |
| 2019-09-06 09:41:36 | PLANS AND PLATS REVIEW COMMITTEE (PPRC) ZONING REVIEW | | | (RESUBMITTAL) | | | ________________________________________ | | | | | | DATE OF REVIEW: 09.05.2019 | | | PROJECT NO.: Z19050026 | | | CASE NO.: PB1086B | | | ________________________________________ | | | | | | PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING | | | REVIEW COMMENTS WHICH WERE ISSUED PREVIOUSLY, AND HAVE | | | NOT BEEN FULLY SATISFIED: | | | | | | 1. [ PARTIALLY SATISFIED ] - UTILITY LETTERS SHALL BE | | | PROVIDED INDICATING NO OBJECTION TO THE PROPOSED | | | IMPROVEMENTS. | | | | | | 1.1. [ NEW COMMENT ] - LETTERS FROM FPL AND AT&T SHALL | | | BE PROVIDED. | | | | | | 2. [ PARTIALLY SATISFIED ] - THE SITE PLAN IS UNCLEAR | | | AS TO WHAT IMPROVEMENTS ARE EXISTING AND WHICH ONES ARE | | | PROPOSED. AS SUCH, IT IS DIFFICULT TO DETERMINE WHAT IS | | | NONCONFORMING AND MAY NEED TO BE BROUGHT INTO | | | COMPLIANCE, ETC. | | | | | | 2.1. [ NEW COMMENT ] - THERE APPEARS TO BE A NUMBER OF | | | IMPROVEMENTS TO THE WEST OF, AND UNDERNEATH, THE | | | EXISTING OFFICE BUILDING THAT ARE NOT SHOWN AS BEING | | | INCLUDED IN THE ?AFFECTED AREA?. THE IMPROVEMENTS | | | INCLUDE THE ADDITION OF BICYCLE PARKING, A DUMPSTER | | | ENCLOSURE, TERMINATION OF THE PARKING DRIVE AISLE | | | UNDERNEATH THE BUILDING DUE TO THE RAMP FOR THE PARKING | | | DECK, ETC. PLEASE NOTE THAT THERE ARE NEW COMMENTS | | | PROVIDED THAT RELATE TO ADDITIONAL CONCERNS WITH THESE | | | ITEMS. | | | | | | 3. [ PARTIALLY SATISFIED ] - AS A FOLLOW UP TO PREVIOUS | | | DISCUSSIONS, WHAT IS THE LATEST REGARDING THE DESIGN OF | | | THE FUTURE GROCER AND THE ACTIVATION OF THE SOUTH DIXIE | | | HIGHWAY CORRIDOR? | | | | | | 3.1. [ NEW COMMENT ] - A SMALL OUTDOOR SEATING AREA WAS | | | ADDED TO THE ARCHITECTURAL PLANS, BUT THIS IS NOT SHOWN | | | ON THE SITE OR LANDSCAPE PLANS. ADDITIONALLY, IT IS | | | UNCLEAR HOW THIS SEATING AREA CAN BE ACCESSED. | | | | | | 4. [ SATISFIED ] - THE SITE PLAN IS UNCLEAR AS TO THE | | | LOCATION OF THE RAMP THAT PROVIDES ACCESS TO THE TOP OF | | | THE PARKING DECK. IT SEEMS THAT THE RAMP MAY IMPEDE | | | WITH MULTIPLE DRIVE AISLES AND OVERALL SITE | | | CIRCULATION, IMPACTING EXISTING PARKING. | | | | | | 5. [ NOT SATISFIED ] - THE PROPOSED PARKING DECK | | | APPEARS TO CONFLICT WITH MULTIPLE UTILITY LINES, | | | ESPECIALLY A WATER MAIN LOCATED WITHIN A 10-FOOT | | | EASEMENT AND A SIX (6) FOOT UNDERGROUND UTILITY | | | EASEMENT. | | | | | | 5.1. [ NEW COMMENT ] - A PORTION OF THE PARKING DECK | | | (NORTHEAST CORNER) STILL EXTENDS INTO THE SIX (6) FOOT | | | UNDERGROUND UTILITY EASEMENT. | | | | | | 5.2. [ CONDITION OF APPROVAL ] - THE SITE PLAN SHOWS A | | | PROPOSED 10-FOOT WATER EASEMENT, BUT WHAT IS PROPOSED | | | TO HAPPEN WITH THE EXISTING EASEMENT THAT IS SHOWN | | | UNDER THE PROPOSED PARKING DECK? THE ENGINEERING PLANS | | | INDICATE THAT THIS IS GOING TO BE ABANDONED. IF SO, THE | | | UTILITY WORK, AND MODIFICATIONS TO THE EASEMENT WILL BE | | | REQUIRED PRIOR TO ISSUANCE OF ANY PERMITS FOR THE | | | PARKING DECK. | | | | | | 5.3. [ NEW COMMENT ] - A NUMBER OF IMPROVEMENTS ARE | | | SHOWN IN THE 12-FOOT FPL EASEMENT IMMEDIATELY NORTH OF | | | THE WAREHOUSE BUILDING. | | | | | | 5.4. [ NEW COMMENT ] - A NUMBER OF IMPROVEMENTS ARE | | | SHOWN IN THE FPL EASEMENT WEST OF THE EXISTING OFFICE | | | BUILDING. | | | | | | 6. [ SATISFIED ] - THE PARKING DECK SHOULD BE ADDED | | | INTO THE SITE DATA TABLE FOR ALL APPLICABLE | | | CALCULATIONS (LOT COVERAGE, IMPERVIOUS, BUILDING | | | SETBACKS, BUILDING HEIGHT, ETC.). IT IS REQUIRED TO | | | COMPLY WITH THE SAME REGULATIONS AS OTHER BUILDINGS IN | | | THE GENERAL COMMERCIAL (GC) ZONING DISTRICT. | | | | | | 7. [ SATISFIED ] - PURSUANT TO SEC. 94-145(7), THE | | | MINIMUM BUILDING SEPARATION SHALL BE ZERO FEET, OR NOT | | | LESS THAN TEN (10) FEET. ACCORDING TO THE SITE PLAN, | | | THE PARKING DECK IS ONLY 4.5 FEET FROM THE EXISTING | | | OFFICE BUILDING. | | | | | | 8. [ SATISFIED ] - BY DEFINITION, THE FRONT OF THE | | | PROPERTY IS ALONG BELVEDERE ROAD AND MONCEAUX ROAD; | | | SOUTH DIXIE HIGHWAY IS CONSIDERED A CORNER-SIDE. | | | | | | 9. [ PARTIALLY SATISFIED - SEE CONDITION OF APPROVAL | | | BELOW ] - IN DISCUSSION AMONGST STAFF, IT WAS SUGGESTED | | | THAT SINCE A LINER BUILDING IS NOT BEING PROPOSED ALONG | | | SOUTH DIXIE (IN FRONT OF THE PARKING DECK, ETC.) THAT | | | SOME ARCHITECTURAL ELEMENTS OR DECORATIVE FEATURES | | | (SUCH AS A TRELLIS, ETC.) COULD BE INCORPORATED INTO, | | | OR IN PLACE OF, THE EASTERN MOST ROW OF PARKING. | | | | | | 9.1. [ NEW COMMENT ] - WHAT WAS THE OBJECTION TO THE | | | INSTALLATION OF A TRELLIS, ETC.? | | | | | | 9.2. [ CONDITION OF APPROVAL ] - THE PROVISION OF BUS | | | SHELTER AND THE DESIGN OF SUCH SHALL BE INCLUDED AS | | | PART OF THE FUTURE MAJOR AMENDMENT. | | | | | | 10. [ SATISFIED ] - THERE SEEMS TO BE A LARGE NUMBER OF | | | SMALL CAR SPACES CONCENTRATED IN SOME OF THE AREA WHERE | | | PARKING DEMAND WILL BE HEAVIEST. PURSUANT TO SEC. | | | 94-485(N)(1)E., SMALL CAR SPACES ARE TO BE DISTRIBUTED. | | | | | | 11. [ SATISFIED ] - YOU WILL NEED TO CONFIRM WITH THE | | | BUILDING DIVISION, BUT ACCESSIBLE PARKING MAY NEED TO | | | BE PROVIDED UNDER THE COVER OF THE PARKING DECK. | | | | | | 12. [ SATISFIED - SEE CONDITION OF APPROVAL BELOW ] - | | | THE SQUARE FOOTAGES IN THE TRAFFIC ANALYSIS AND PBC | | | TRAFFIC CONCURRENCY DETERMINATION DO NOT SEEM TO | | | CORRESPOND WITH THE SQUARE FOOTAGES THAT ARE SHOWN ON | | | THE SITE PLAN. PLEASE ENSURE THAT ALL PLANS, STUDIES, | | | ETC. ARE CONSISTENT. | | | | | | 12.1. [ CONDITION OF APPROVAL ] - A CONDITION OF | | | APPROVAL WILL EXIST REGARDING THE MAXIMUM SQUARE | | | FOOTAGE THAT CAN BE OCCUPIED, AND THAT THE TRAFFIC | | | ANALYSIS AND CONCURRENCY DETERMINATION BE UPDATED AS | | | PART OF FUTURE DEVELOPMENT. | | | | | | 13. [ SATISFIED - SEE CONDITION OF APPROVAL BELOW ] - | | | THE TRAFFIC CONCURRENCY DETERMINATION LETTER FROM PALM | | | BEACH COUNTY INDICATES THAT THE PROJECT IS TO ?MEET | | | CRITERIA AS OUTLINED IN THE CITY?S TDM (TRANSPORTATION | | | DEMAND MANAGEMENT) ORDINANCE.? PLEASE PROVIDE DETAILS | | | AS THERE IS NO TDM ORDINANCE THAT HAS BEEN ADOPTED FOR | | | THIS AREA. | | | | | | 13.1. [ CONDITION OF APPROVAL ] - A CONDITION OF | | | APPROVAL WILL EXIST REGARDING THE MAXIMUM SQUARE | | | FOOTAGE THAT CAN BE OCCUPIED. | | | | | | 14. [ NOT SATISFIED ] - THE TRAFFIC IMPACT ANALYSIS | | | REFERENCES THAT THE PROJECT WILL BE PARTICIPATING IN | | | THE CITY?S MOBILITY FUNDS PROGRAM; PLEASE NOTE THAT NO | | | SUCH PROGRAM HAS BEEN ADOPTED, AND UNDER THE ?PROPOSED? | | | PROGRAM, THE SUBJECT PROPERTY IS OUTSIDE THE BOUNDARIES | | | OF SUCH PROGRAM. | | | | | | 14.1. [ NEW COMMENT ] - THE TRAFFIC IMPACT ANALYSIS | | | SHOULD HAVEN BEEN REVISED TO REMOVE REFERENCE TO THE | | | MOBILITY FUND AND TDM PROGRAM. | | | | | | 15. [ PARTIALLY SATISFIED ] - PURSUANT TO THE PBC | | | TRAFFIC CONCURRENCY DETERMINATION LETTER, AN FDOT | | | CONCEPTUAL DRIVEWAY PRE-APPROVAL LETTER SHALL BE | | | OBTAINED. SPECIAL ATTENTION SHOULD BE PROVIDED | | | REGARDING THE COUNTY?S SUGGESTION OF A CENTER LEFT TURN | | | LANE. | | | | | | 15.1. [ NEW COMMENT ] - THE LETTER FROM FDOT INDICATES | | | THAT ALL OF THE DRIVEWAYS ARE RIGHT IN/RIGHT OUT, BUT | | | THE STRIPING AND DESIGN SHOWN ON THE SITE PLAN DOES NOT | | | INDICATE SUCH. | | | | | | 16. [ PARTIALLY SATISFIED ] - SIDEWALKS/CROSSINGS SHALL | | | BE PROVIDED FROM THE PEDESTRIAN EXIT POINTS OF THE | | | PARKING DECK TO BUILDINGS #1 AND #3. | | | | | | 16.1. [ NEW COMMENT ] - THERE?S CONCERN REGARDING THE | | | DESIGN OF THE CROSSWALK, STOP SIGN, ETC. THAT IS | | | PROPOSED IN THE SOUTHWEST CORNER OF THE PARKING DECK. | | | THE STOP SIGN APPEARS TO BE FLOATING IN THE DRIVE | | | AISLE, PEDESTRIANS ARE DIRECTED TO WALK IN FRONT OF | | | VEHICLES BEFORE CROSSING THE DRIVEWAY, ETC. THE | | | ISLAND/LANDING AT THE BASE OF THE STAIRS SHOULD BE | | | EXTENDED TO THE EDGE OF THE DRIVE AISLE, ALLOWING FOR | | | PLACEMENT OF THE STOP SIGN, AND THE CROSS WALK CAN GO | | | FROM THE SOUTH EDGE OF THE LANDING. | | | | | | 17. [ SATISFIED - SEE CONDITION OF APPROVAL BELOW ] - | | | SIGNAGE SHOULD BE REMOVED FROM THE ARCHITECTURAL | | | DRAWINGS AND SHOULD BE REVIEWED AS A SEPARATE SIGN | | | PACKAGE. | | | | | | 17.1. [ CONDITION OF APPROVAL ] - ALL SIGNAGE WILL BE | | | REVIEWED AT THE TIME OF PERMITTING AND SHALL COMPLY | | | WITH THE ZLDRS. | | | | | | 18. [ SATISFIED - SEE CONDITION OF APPROVAL BELOW ] - | | | ADDITIONAL INFORMATION WILL NEED TO BE PROVIDED FOR | | | REVIEW OF THE FREESTANDING SIGNS: | | | | | | 18.1. [ SATISFIED - SEE CONDITION OF APPROVAL BELOW ] - | | | SETBACK SHALL BE PROVIDED FROM ALL FREESTANDING SIGNS | | | TO THE ADJACENT PROPERTY LINE, AND SHALL COMPLY WITH | | | THE APPLICABLE PROVISIONS OF SEC. 94-408(D)(2) AND (3). | | | | | | 18.2. [ SATISFIED - SEE CONDITION OF APPROVAL BELOW ] - | | | SQUARE FOOTAGE OF FREESTANDING SIGN AREA SHALL BE | | | PROVIDED AND SHALL COMPLY WITH THE APPLICABLE | | | PROVISIONS OF SEC. 94-408(D)(2) AND (3). | | | | | | 18.3. [ CONDITION OF APPROVAL ] - ALL SIGNAGE WILL BE | | | REVIEWED AT THE TIME OF PERMITTING AND SHALL COMPLY | | | WITH THE ZLDRS. | | | | | | 19. [ NOT SATISFIED ] - SCREENING SHALL BE PROVIDED FOR | | | THE TRASH COMPACTOR IN ACCORDANCE WITH SEC. 94-315(A). | | | | | | 19.1. [ NEW COMMENT ] - STAFF DOES NOT UNDERSTAND THE | | | RESPONSE THAT WAS PROVIDED. PLEASE CLARIFY HOW THE | | | TRASH COMPACTOR IS PROPOSED TO COMPLY WITH THE CITED | | | PROVISION OF THE CITY?S ZLDRS. | | | | | | 20. [ SATISFIED ] - IT IS STAFF'S POSITION THAT | | | LANDSCAPING SHALL BE PROVIDED ALONG THE OUTER PERIMETER | | | OF THE PARKING DECK (SPECIFICALLY THE EAST AND SOUTH | | | SIDES) TO SOFTEN THE APPEARANCE OF THE STRUCTURE AND | | | MAKE IT BLEND IN WITH THE REMAINDER OF THE SITE. | | | | | | 21. [ PARTIALLY SATISFIED ] - MULTIPLE STRUCTURAL | | | COLUMNS FOR THE PARKING DECK ENCROACH INTO DRIVE | | | AISLES, PARKING SPACES, ETC. ON THE GROUND LEVEL. | | | | | | 21.1. [ NEW COMMENT ] - PLEASE CONFIRM THAT NO COLUMNS | | | ARE PROPOSED ON THE INTERIOR (GROUND LEVEL) OF THE | | | PARKING DECK. IF COLUMNS ARE PROPOSED, THEY SHALL BE | | | SHOWN ON THE PLAN TO INDICATE THAT THEY DO NOT CONFLICT | | | WITH PARKING SPACES OR DRIVE AISLES AND/OR THAT THE | | | STRIPING IS ADJUSTED ACCORDINGLY TO ACCOMMODATE THEM. | | | | | | 22. [ NOT SATISFIED ] - THE PARKING STALL DETAIL ON | | | SHEET 12 OF THE ENGINEERING PLANS SHALL CONFORM TO THE | | | CITY?S MINIMUM REQUIREMENTS. | | | | | | 23. [ SATISFIED ] - THE BICYCLE PARKING DETAIL | | | REFERENCES THE SITE PLAN FOR DIMENSIONS, ETC., BUT NO | | | DIMENSIONS WERE PROVIDED. | | | | | | 24. [ SATISFIED ] - BICYCLE PARKING NEEDS TO BE | | | DISTRIBUTED THROUGHOUT THE SITE BASED UPON THE USES ON | | | THE PROPERTY, AND SHALL BE SITUATED IN PROXIMITY TO | | | BUILDING ENTRANCE, ETC. SO AS TO BE VISIBLE TO PATRONS. | | | THE LOCATION OF THE BICYCLE PARKING FOR BUILDING #1 IS | | | OF GREATEST CONCERN. | | | | | | 25. [ NEW COMMENT ] - WITH THE CREATION OF THE DEAD-END | | | DRIVE AISLE UNDERNEATH THE EXISTING OFFICE BUILDING, A | | | TURN-AROUND SPACE SHALL BE PROVIDED. | | | | | | 26. [ NEW COMMENT ] - WITH THE CREATION OF THE DEAD-END | | | DRIVE AISLE UNDERNEATH THE PROPOSED PARKING DECK, A | | | TURN-AROUND SPACE SHALL BE PROVIDED. | | | | | | 27. [ NEW COMMENT ] - THE BICYCLE PARKING PROVIDED WEST | | | OF THE EXISTING OFFICE BUILDING APPEARS TO BE | | | ENCROACHING INTO THE DRIVE AISLE AND COULD EASILY BE | | | DAMAGED BY PASSING VEHICLES, ETC. | | | | | | 28. [ NEW COMMENT ] - LANDSCAPING AROUND THE BASE OF | | | THE ENCLOSURE IS REQUIRED. | | | | | | 29. [ NEW COMMENT ] - PLEASE CLARIFY THE DESIGN | | | PROPOSED IMMEDIATELY NORTH OF THE WAREHOUSE BUILDING. | | | IS CURBING PROPOSED BETWEEN THE DRIVEWAY AND THE FRONT | | | ENTRANCE? IF NOT, AND THE DRIVEWAY IS AT THE SAME | | | ELEVATION AS THE ENTRY, SOME FORM OF | | | PEDESTRIAN-FRIENDLY BARRIER SHOULD BE CONSIDERED TO | | | KEEP VEHICLES FROM ENCROACHING INTO THE PEDESTRIAN | | | AREA. | | | | | | 30. [ NEW COMMENT ] - THERE IS A LARGE AMOUNT OF | | | UTILITY EQUIPMENT (WATER METERS, BACKFLOW, ETC.) | | | IMMEDIATELY IN FRONT OF THE PROPOSED GROCER; SUCH | | | EQUIPMENT NEEDS TO BE SCREENED. | | | | | | 31. [ NEW COMMENT ] - THE SITE AND LANDSCAPE PLANS SHOW | | | A DOOR EXITING THE FRONT OF THE GROCER WITH A SET OF | | | STAIRS LEADING DOWN. PLEASE CLARIFY AS THIS IS NOT | | | SHOWN ON ANY OTHER PLAN. | | | | | | 32. [ NEW COMMENT ] - ON THE ENGINEERING PLANS IT | | | APPEARS THAT THERE IS NOT SUFFICIENT CLEAR WIDTH | | | BETWEEN THE HANDICAP PARKING SIGNS, CAUSING THIS ROUTE | | | TO NOT BE ADA COMPLIANT. PLEASE VERIFY. | | | | | | 33. [ NEW COMMENT ] - ON THE SITE PLAN, THE DETAIL FOR | | | THE SECOND LEVEL OF THE PARKING DECK HAS A LABEL FOR A | | | TYPICAL LIGHT POLE THAT IS PLACED INCORRECTLY. | | | ___________________________________________ | | | | | | PLEASE NOTE THE FOLLOWING WHEN RESUBMITTING: | | | | | | A) WRITTEN RESPONSES TO COMMENTS MADE BY ALL | | | DEPARTMENTS SHALL BE PROVIDED UPON RESUBMISSION. | | | | | | B) FOUR (4) SETS OF REVISED PLANS AND/OR DOCUMENTS | | | SHALL BE PROVIDED, ALONG WITH ONE (1) REDUCED COPY | | | (11IN X 17IN), AND AN ELECTRONIC COPY OF ALL PLANS. | | | | | | C) PLEASE NOTE THAT RE-SUBMITTALS MAY BE SUBJECT TO | | | ADDITIONAL COMMENTS. | | | | | | D) IF NO RESPONSE IS RECEIVED WITHIN 60 DAYS OF THE | | | ISSUANCE OF THESE COMMENTS, THE APPLICATION WILL BE | | | CONSIDERED WITHDRAWN AND ANY FURTHER ACTION WILL | | | REQUIRE SUBMISSION OF A NEW DEVELOPMENT APPLICATION. | | | | | | E) PLEASE NOTE THAT YOU WILL BE PERMITTED ONE (1) | | | RESUBMITTAL AT NO ADDITIONAL COST. IF PREVIOUSLY ISSUED | | | COMMENTS CONTINUE TO NOT BE SUFFICIENTLY ADDRESSED, THE | | | APPLICANT WILL BE ACCESSED A RESUBMITTAL FEE. SUCH FEE | | | WILL BE 20% OF THE ORIGINAL APPLICATION FEE. | | | ___________________________________________ | | | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | | | JOHN P. ROACH, AICP, PRINCIPAL PLANNER | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES DEPARTMENT - PLANNING DIVISION | | | 401 CLEMATIS STREET - P.O. BOX 3147 | | | WEST PALM BEACH, FLORIDA 33402 | | | | | | P: 561.822.1448 | | | E: [email protected] | | | | | | W: WPB.ORG |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
06-12-2019 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
06-12-2019 |
Time |
11:19 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
06-12-2019 |
Time |
11:19 |
Sent To |
|
|
| Notes |
| 2019-06-12 11:20:07 | PLANS AND PLATS REVIEW COMMITTEE (PPRC) ZONING REVIEW | | | ___________________________________________ | | | | | | DATE OF REVIEW: 06.12.2019 | | | PROJECT NO.: Z19050026 | | | CASE NO.: PB 1086B | | | ___________________________________________ | | | | | | PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING | | | REVIEW COMMENTS: | | | | | | 1. UTILITY LETTERS SHALL BE PROVIDED INDICATING NO | | | OBJECTION TO THE PROPOSED IMPROVEMENTS. | | | | | | 2. THE SITE PLAN IS UNCLEAR AS TO WHAT IMPROVEMENTS ARE | | | EXISTING AND WHICH ONES ARE PROPOSED. AS SUCH, IT IS | | | DIFFICULT TO DETERMINE WHAT IS NONCONFORMING AND MAY | | | NEED TO BE BROUGHT INTO COMPLIANCE, ETC. | | | | | | 3. AS A FOLLOW UP TO PREVIOUS DISCUSSIONS, WHAT IS THE | | | LATEST REGARDING THE DESIGN OF THE FUTURE GROCER AND | | | THE ACTIVATION OF THE SOUTH DIXIE HIGHWAY CORRIDOR? | | | | | | 4. THE SITE PLAN IS UNCLEAR AS TO THE LOCATION OF THE | | | RAMP THAT PROVIDES ACCESS TO THE TOP OF THE PARKING | | | DECK. IT SEEMS THAT THE RAMP MAY IMPEDE WITH MULTIPLE | | | DRIVE AISLES AND OVERALL SITE CIRCULATION, IMPACTING | | | EXISTING PARKING. | | | | | | 5. THE PROPOSED PARKING DECK APPEARS TO CONFLICT WITH | | | MULTIPLE UTILITY LINES, ESPECIALLY A WATER MAIN LOCATED | | | WITHIN A 10-FOOT EASEMENT AND A SIX (6) FOOT | | | UNDERGROUND UTILITY EASEMENT. | | | | | | 6. THE PARKING DECK SHOULD BE ADDED INTO THE SITE DATA | | | TABLE FOR ALL APPLICABLE CALCULATIONS (LOT COVERAGE, | | | IMPERVIOUS, BUILDING SETBACKS, BUILDING HEIGHT, ETC.). | | | IT IS REQUIRED TO COMPLY WITH THE SAME REGULATIONS AS | | | OTHER BUILDINGS IN THE GENERAL COMMERCIAL (GC) ZONING | | | DISTRICT). | | | | | | 7. PURSUANT TO SEC. 94-145(7), THE MINIMUM BUILDING | | | SEPARATION SHALL BE ZERO FEET, OR NOT LESS THAN TEN | | | (10) FEET. ACCORDING TO THE SITE PLAN, THE PARKING DECK | | | IS ONLY 4.5 FEET FROM THE EXISTING OFFICE BUILDING. | | | | | | 8. BY DEFINITION, THE FRONT OF THE PROPERTY IS ALONG | | | BELVEDERE ROAD AND MONCEAUX ROAD; SOUTH DIXIE HIGHWAY | | | IS CONSIDERED A CORNER-SIDE. | | | | | | 9. IN DISCUSSION AMONGST STAFF, IT WAS SUGGESTED THAT | | | SINCE A LINER BUILDING IS NOT BEING PROPOSED ALONG | | | SOUTH DIXIE (IN FRONT OF THE PARKING DECK, ETC.) THAT | | | SOME ARCHITECTURAL ELEMENTS OR DECORATIVE FEATURES | | | (SUCH AS TRELLIS?, ETC.) COULD BE INCORPORATED INTO, OR | | | IN PLACE OF, THE EASTERN MOST ROW OF PARKING. | | | | | | 10. THERE SEEMS TO BE A LARGE NUMBER OF SMALL CAR | | | SPACES CONCENTRATED IN SOME OF THE AREA WHERE PARKING | | | DEMAND WILL BE HEAVIEST. PURSUANT TO SEC. | | | 94-485(N)(1)E., SMALL CAR SPACES ARE TO BE DISTRIBUTED. | | | | | | 11. YOU WILL NEED TO CONFIRM WITH THE BUILDING | | | DIVISION, BUT ACCESSIBLE PARKING MAY NEED TO BE | | | PROVIDED UNDER THE COVER OF THE PARKING DECK. | | | | | | 12. THE SQUARE FOOTAGES IN THE TRAFFIC ANALYSIS AND PBC | | | TRAFFIC CONCURRENCY DETERMINATION DO NOT SEEM TO | | | CORRESPOND WITH THE SQUARE FOOTAGES THAT ARE SHOWN ON | | | THE SITE PLAN. PLEASE ENSURE THAT ALL PLANS, STUDIES, | | | ETC. ARE CONSISTENT. | | | | | | 13. THE TRAFFIC CONCURRENCY DETERMINATION LETTER FROM | | | PALM BEACH COUNTY INDICATES THAT THE PROJECT IS TO | | | ?MEET CRITERIA AS OUTLINED IN THE CITY?S TDM | | | (TRANSPORTATION DEMAND MANAGEMENT) ORDINANCE.? PLEASE | | | PROVIDE DETAILS AS THERE IS NO TDM ORDINANCE THAT HAS | | | BEEN ADOPTED FOR THIS AREA. | | | | | | 14. THE TRAFFIC IMPACT ANALYSIS REFERENCES THAT THE | | | PROJECT WILL BE PARTICIPATING IN THE CITY?S MOBILITY | | | FUNDS PROGRAM; PLEASE NOTE THAT NO SUCH PROGRAM HAS | | | BEEN ADOPTED, AND UNDER THE ?PROPOSED? PROGRAM, THE | | | SUBJECT PROPERTY IS OUTSIDE THE BOUNDARIES OF SUCH | | | PROGRAM. | | | | | | 15. PURSUANT TO THE PBC TRAFFIC CONCURRENCY | | | DETERMINATION LETTER, AN FDOT CONCEPTUAL DRIVEWAY | | | PRE-APPROVAL LETTER SHALL BE OBTAINED. SPECIAL | | | ATTENTION SHOULD BE PROVIDED REGARDING THE COUNTY?S | | | SUGGESTION OF A CENTER LEFT TURN LANE. | | | | | | 16. SIDEWALKS/CROSSINGS SHALL BE PROVIDED FROM THE | | | PEDESTRIAN EXIT POINTS OF THE PARKING DECK TO BUILDINGS | | | #1 AND #3. | | | | | | 17. SIGNAGE SHOULD BE REMOVED FROM THE ARCHITECTURAL | | | DRAWINGS AND SHOULD BE REVIEWED AS A SEPARATE SIGN | | | PACKAGE. | | | | | | 18. ADDITIONAL INFORMATION WILL NEED TO BE PROVIDED FOR | | | REVIEW OF THE FREESTANDING SIGNS: | | | | | | 18.1. SETBACK SHALL BE PROVIDED FROM ALL FREESTANDING | | | SIGNS TO THE ADJACENT PROPERTY LINE, AND SHALL COMPLY | | | WITH THE APPLICABLE PROVISIONS OF SEC. 94-408(D)(2) AND | | | (3). | | | | | | 18.2. SQUARE FOOTAGE OF FREESTANDING SIGN AREA SHALL BE | | | PROVIDED AND SHALL COMPLY WITH THE APPLICABLE | | | PROVISIONS OF SEC. 94-408(D)(2) AND (3). | | | | | | 19. SCREENING SHALL BE PROVIDED FOR THE TRASH COMPACTOR | | | IN ACCORDANCE WITH SEC. 94-315(A). | | | | | | 20. IT IS STAFF?S POSITION THAT LANDSCAPING SHALL BE | | | PROVIDED ALONG THE OUTER PERIMETER OF THE PARKING DECK | | | (SPECIFICALLY THE EAST AND SOUTH SIDES) TO SOFTEN THE | | | APPEARANCE OF THE STRUCTURE AND MAKE IT BLEND IN WITH | | | THE REMAINDER OF THE SITE. | | | | | | 21. MULTIPLE STRUCTURAL COLUMNS FOR THE PARKING DECK | | | ENCROACH INTO DRIVE AISLES, PARKING SPACES, ETC. ON THE | | | GROUND LEVEL. | | | | | | 22. THE PARKING STALL DETAIL ON SHEET 12 OF THE | | | ENGINEERING PLANS SHALL CONFORM TO THE CITY?S MINIMUM | | | REQUIREMENTS. | | | | | | 23. THE BICYCLE PARKING DETAIL REFERENCES THE SITE PLAN | | | FOR DIMENSIONS, ETC., BUT NO DIMENSIONS WERE PROVIDED. | | | | | | 24. BICYCLE PARKING NEEDS TO BE DISTRIBUTED THROUGHOUT | | | THE SITE BASED UPON THE USES ON THE PROPERTY, AND SHALL | | | BE SITUATED IN PROXIMITY TO BUILDING ENTRANCE, ETC. SO | | | AS TO BE VISIBLE TO PATRONS. THE LOCATION OF THE | | | BICYCLE PARKING FOR BUILDING #1 IS OF GREATEST CONCERN. | | | ___________________________________________ | | | | | | PLEASE NOTE THE FOLLOWING WHEN RESUBMITTING: | | | | | | A) WRITTEN RESPONSES TO COMMENTS MADE BY ALL | | | DEPARTMENTS SHALL BE PROVIDED UPON RESUBMISSION. | | | | | | B) FOUR (4) SETS OF REVISED PLANS AND/OR DOCUMENTS | | | SHALL BE PROVIDED, ALONG WITH ONE (1) REDUCED COPY | | | (11IN X 17IN), AND AN ELECTRONIC COPY OF ALL PLANS. | | | | | | C) PLEASE NOTE THAT RE-SUBMITTALS MAY BE SUBJECT TO | | | ADDITIONAL COMMENTS. | | | | | | D) IF NO RESPONSE IS RECEIVED WITHIN 60 DAYS OF THE | | | ISSUANCE OF THESE COMMENTS, THE APPLICATION WILL BE | | | CONSIDERED WITHDRAWN AND ANY FURTHER ACTION WILL | | | REQUIRE SUBMISSION OF A NEW DEVELOPMENT APPLICATION. | | | | | | E) PLEASE NOTE THAT YOU WILL BE PERMITTED ONE (1) | | | RESUBMITTAL AT NO ADDITIONAL COST. IF PREVIOUSLY-ISSUED | | | COMMENTS CONTINUE TO NOT BE SUFFICIENTLY ADDRESSED, THE | | | APPLICANT WILL BE ACCESSED A RESUBMITTAL FEE. SUCH FEE | | | WILL BE 20% OF THE ORIGINAL APPLICATION FEE. | | | ___________________________________________ | | | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | | | JOHN P. ROACH, AICP, PRINCIPAL PLANNER | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION | | | 401 CLEMATIS STREET - P.O. BOX 3147 | | | WEST PALM BEACH, FLORIDA 33402 | | | | | | P: 561.822.1448 | | | E: [email protected] | | | | | | W: WPB.ORG | | | |
|
|
| |