| 2019-09-19 20:28:04 | DEVELOPMENT SERVICES DEPARTMENT, BUILDING DIVISION, | | | COMMENTS: | | | | | | 1. THIS IS THE THIRD REVIEW. THE SUBMITTED LETTER | | | RESPONSES TO THE PREVIOUS COMMENTS ARE NOTED. ALL | | | INFORMATIONAL COMMENTS PROVIDED IN THE FIRST REVIEW | | | STILL APPLY. | | | | | | 2. LOCATION OF ACCESSIBLE PARKING SPACES. A SCANNED | | | MARK UP OF THE SUGGESTED SOLUTION DESCRIBED BELOW CAN | | | BE MADE AVAILABLE. ACCORDING TO THE ACTIVE USE | | | DIAGRAMS, SHEET A0.06, AND EXISTING PARKING GARAGE | | | PARKING COUNT, SHEET A0.11, ACCESS TO THE RESIDENTIAL | | | OCCUPANCY WILL BE VIA THE HIBISCUS ST DOORS TO THE 1ST | | | FLOOR LOBBY, OR VIA THE LEVEL 2 (PARKING LEVEL 3) | | | BRIDGE FROM THE PARKING GARAGE. GIVEN THE CONVENIENCE | | | AND WEATHER PROTECTION OFFERED BY THE LEVEL 2 (PARKING | | | LEVEL 3) BRIDGE, AND THE TRAVEL DISTANCE FROM CAR TO | | | RESIDENTIAL UNIT BEING SHORTER, AT LEAST 50% OF THE | | | RESIDENTIAL SPACE OCCUPANTS WOULD BE EXPECTED TO USE | | | THE BRIDGE TO GO FROM THE PARKING GARAGE TO THE NEW | | | BUILDING. YET ONLY 29% (2 OUT OF 7) OF THE ACCESSIBLE | | | PARKING SPACES REQUIRED BY FAIR HOUSING ACT ARE THE | | | CLOSEST PARKING SPACES TO THE BRIDGE. AS STATED IN THE | | | PREVIOUS REVIEW, THAT MEANS THAT SOME PEOPLE NEEDING | | | ACCESSIBLE PARKING SPACES WILL BE TRAVELING FURTHER TO | | | ACCESS THE BUILDING THAN PEOPLE WHO DO NOT NEED | | | ACCESSIBLE PARKING SPACES. THEY WILL ALSO BE MORE | | | EXPOSED TO THE ELEMENTS AND VEHICULAR TRAFFIC IF THEY | | | TAKE THE ELEVATOR TO GROUND AND THEN CROSS THE STREET. | | | CONSIDERING THE PROBABILITY THAT THE OCCUPANTS OF AT | | | LEAST 50% OF THE RESIDENTIAL SPACE OCCUPANTS WILL | | | ACCESS THE NEW BUILDING VIA THE LEVEL 2 BRIDGE, AT | | | LEAST 4 OF THE 7 ACCESSIBLE PARKING SPACES REQUIRED BY | | | FAIR HOUSING ACT SHOULD BE LOCATED AS THE CLOSEST | | | PARKING SPACES TO THE BRIDGE ENTRANCE, BUT ONLY 2 ARE | | | CURRENTLY SHOWN AS ACCESSIBLE. | | | SUGGESTION: IF THE EXISTING SOUTH-EAST PARKING "END | | | CAP" THAT IS CLOSEST TO THE BRIDGE WERE TO BE USED TO | | | MOVE THE DRIVE LANES CLOSER TO THE CENTER OF THE | | | PARKING GARAGE BUILDING, THAT MAY PROVIDE ENOUGH SPACE | | | TO ADD TWO MORE ACCESSIBLE PARKING SPACES ALONG THE | | | SOUTH WALL NEXT TO THE ONE ALREADY PROVIDED. THE | | | WHEELCHAIR ACCESS AISLE COULD THEN BE AGAINST THE | | | EXTERIOR WALL AND PROTECTED BY BOLLARDS/WHEEL STOPS. | | | THE SUBJECT EXISTING SOUTH-EAST PARKING "END CAP" THAT | | | IS CLOSEST TO THE BRIDGE IS PROBABLY JUST A PAINTED OUT | | | AREA OF SLAB THAT COULD BE USED TO REALIGN THE DRIVE | | | LANES. ALSO, THE ACCESSIBLE PARKING SPACE THAT IS | | | ALREADY SHOWN COULD HAVE ITS ACCESS AISLE MOVED TO THE | | | WEST SIDE OF THE PARKING SPACE SO THAT THE PARKING | | | SPACE CAN BE MOVED TO THE EAST AND THE ACCESS AISLE | | | SHARED WITH THE NEXT ACCESSIBLE PARKING SPACE THAT THIS | | | SUGGESTION WOULD ADD. A SCANNED MARK UP OF THIS | | | SUGGESTION HAS BEEN SENT TO ERIC SCHNEIDER BY EMAIL SO | | | THAT HE CAN MAKE IT AVAILABLE TO YOU. | | | PER SECTION 208.3 OF FLORIDA ACCESSIBILITY CODE, | | | ACCESSIBLE PARKING SPACES ARE TO BE LOCATED ON THE | | | SHORTEST POSSIBLE ROUTE OF TRAVEL FROM ADJACENT PARKING | | | TO AN ACCESSIBLE ENTRANCE. THE DESIGN OF ACCESSIBLE | | | PARKING SPACES SHALL COMPLY WITH SECTION 502 OF FLORIDA | | | ACCESSIBILITY CODE | | | | | | | | | ROBERT BROWN | | | BUILDING OFFICIAL | | | TEL: 561 805 6652 | | | EMAIL: [email protected] | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
08-21-2019 |
|
|
Cont ID |
|
| Sent By |
rbrown |
Date |
08-21-2019 |
Time |
10:18 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
08-21-2019 |
Time |
10:18 |
Sent To |
|
|
| Notes |
| 2019-08-21 10:57:17 | DEVELOPMENT SERVICES DEPARTMENT, BUILDING DIVISION, | | | COMMENTS: | | | | | | 1. THIS IS THE SECOND REVIEW. THE SUBMITTED LETTER | | | RESPONSE TO THE PREVIOUS COMMENTS IS NOTED. ALL | | | INFORMATIONAL COMMENTS PROVIDED IN THE FIRST REVIEW | | | STILL APPLY. | | | | | | 2. LOCATION OF ACCESSIBLE PARKING SPACES. SITE AND | | | PROJECT DATA SHEET A0.01 STATES THAT EXISTING SHARED | | | PARKING WILL BE USED, AND A TOTAL OF 379 PARKING SPACES | | | WILL BE PROVIDED, INCLUDING 9 ACCESSIBLE PARKING | | | SPACES. BASED ON THE NUMBER OF PARKING SPACES FOR | | | RESIDENTIAL USE, PER FAIR HOUSING ACT, 7 ACCESSIBLE | | | PARKING SPACES MUST BE AVAILABLE FOR THE RESIDENTIAL | | | OCCUPANCY. ACCORDING TO THE ACTIVE USE DIAGRAMS, SHEET | | | A0.06, ACCESS TO THE RESIDENTIAL OCCUPANCY WILL BE VIA | | | THE HIBISCUS ST DOORS TO THE 1ST FLOOR LOBBY, OR VIA | | | THE LEVEL 2 BRIDGE FROM THE PARKING GARAGE. THEREFORE, | | | THE 7 ACCESSIBLE SPACES REQUIRED BY THE FAIR HOUSING | | | ACT SHOULD BE THE 7 CLOSEST PARKING SPACES TO THE | | | HIBISCUS ST DOORS TO THE 1ST FLOOR LOBBY, AND THE LEVEL | | | 2 BRIDGE. GROUND LEVEL FLOOR PLAN, SHEET A1.01, AND 2ND | | | LEVEL FLOOR PLAN, SHEET A1.02, SHOW 5 ACCESSIBLE | | | PARKING SPACES AS THE CLOSEST TO THOSE ENTRANCES. THE | | | REMAININING ACCESSIBLE PARKING SPACES SHOWN ON 3RD | | | LEVEL THROUGH PENTHOUSE LEVEL FLOOR PLAN, SHEETS A1.03 | | | THROUGH A1.06, ARE FURTHER FROM THOSE TWO ENTRANCES | | | THAN MANY OF THE REGULAR (NON-ACCESSIBLE) PARKING | | | SPACES SHOWN ON GROUND LEVEL FLOOR PLAN, SHEET A1.01, | | | AND 2ND LEVEL FLOOR PLAN, SHEET A1.02. THAT MEANS THAT | | | SOME PEOPLE NEEDING ACCESSIBLE PARKING SPACES WILL BE | | | TRAVELING FURTHER TO ACCESS THE BUILDING THAN SOME | | | PEOPLE WHO DO NOT NEED ACCESSIBLE PARKING SPACES. | | | CONSIDERING THE PROBABILITY THAT THE OCCUPANTS OF MORE | | | THAN 100 OF THE CARS PARKED IN THE GARAGE FOR THE | | | RESIDENTIAL OCCUPANCY WILL ACCESS THE BUILDING VIA THE | | | LEVEL 2 BRIDGE, MORE THAN 2 ACCESSIBLE PARKING SPACES | | | SHOULD BE LOCATED CLOSEST TO THE BRIDGE ENTRANCE, BUT | | | ONLY 2 ARE CURRENTLY SHOWN. ALSO, GROUND LEVEL THROUGH | | | PENTHOUSE LEVEL FLOOR PLAN, SHEETS A1.01 THROUGH A1.06, | | | CURRENTLY SHOW A TOTAL OF 7 ACCESSIBLE PARKING SPACES, | | | WHICH IS LESS THAN THE 9 REQUIRED ACCESSIBLE PARKING | | | SPACES STATED ON SITE AND PROJECT DATA SHEET A0.01. | | | PER SECTION 208.3 OF FLORIDA ACCESSIBILITY CODE, | | | ACCESSIBLE PARKING SPACES ARE TO BE LOCATED ON THE | | | SHORTEST POSSIBLE ROUTE OF TRAVEL FROM ADJACENT PARKING | | | TO AN ACCESSIBLE ENTRANCE. THE DESIGN OF ACCESSIBLE | | | PARKING SPACES SHALL COMPLY WITH SECTION 502 OF FLORIDA | | | ACCESSIBILITY CODE | | | | | | | | | ROBERT BROWN | | | BUILDING OFFICIAL | | | TEL: 561 805 6652 | | | EMAIL: [email protected] | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
06-11-2019 |
|
|
Cont ID |
|
| Sent By |
rbrown |
Date |
06-11-2019 |
Time |
19:31 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
06-11-2019 |
Time |
19:31 |
Sent To |
|
|
| Notes |
| 2019-06-11 19:42:15 | DEVELOPMENT SERVICES DEPARTMENT, BUILDING DIVISION, | | | COMMENTS: | | | | | | 1. THIS REVIEW IS A CURSORY REVIEW AS IT RELATES TO THE | | | SITE. IT IS NOT A REVIEW FOR FULL COMPLIANCE WITH | | | FLORIDA BUILDING CODE. THE FOLLOWING COMMENTS ARE TO BE | | | ADDRESSED FOR THE BUILDING PERMIT APPLICATION. | | | | | | 2. DEMOLITION OF THE EXISTING BUILDING. AN ASBESTOS | | | SURVEY SHALL BE PERFORMED AND AN ASBESTOS ABATEMENT | | | REPORT SUBMITTED TO THE HEALTH DEPARTMENT PALM BEACH | | | COUNTY OFFICE. CONTACT ALEX ORTEGA AT (561) 837-5963, | | | OR BY EMAIL: [email protected] | | | | | | 3. LOCATION OF ACCESSIBLE PARKING SPACES. SITE AND | | | PROJECT DATA SHEET A0.01 STATES THAT EXISTING SHARED | | | PARKING WILL BE USED, BUT THE PLANS DO NOT SHOW THE | | | EXISTING ACCESIBLE PARKING TO BE LOCATED CLOSEST TO THE | | | ENTRANCES OF THE NEW BUILDING. PER SECTION 208.3 OF | | | FLORIDA ACCESSIBILITY CODE, ACCESSIBLE PARKING SPACES | | | ARE TO BE LOCATED ON THE SHORTEST POSSIBLE ROUTE OF | | | TRAVEL FROM ADJACENT PARKING TO AN ACCESSIBLE ENTRANCE. | | | THE DESIGN OF ACCESSIBLE PARKING SPACES SHALL COMPLY | | | WITH SECTION 502 OF FLORIDA ACCESSIBILITY CODE | | | | | | 4. BUILDING SIZE. WHEN SUBMITTED FOR BUILDING PERMIT, | | | THE PLANS SHALL SHOW THAT THE TYPE OF CONSTRUCTION FOR | | | THE BUILDINGS WILL BE IN ACCORDANCE WITH THE HEIGHT, | | | AREA AND OCCUPANCY LIMITATIONS IN CHAPTER 5 OF THE | | | FLORIDA BUILDING CODE. | | | | | | 5. BUILDING LOCATION RELATIVE TO THE PROPERTY LINE AND | | | OTHER STRUCTURES. WHEN SUBMITTED FOR BUILDING PERMIT, | | | COMPLIANCE WITH ALL BUILDING SEPARATION, PERCENTAGE OF | | | OPENINGS AND OPENING PROTECTIVE REQUIREMENTS OF | | | CHAPTERS 6 AND 7 OF THE FLORIDA BUILDING CODE SHALL BE | | | VERIFIED. | | | | | | 6. EGRESS FROM LOBBY. GROUND LEVEL FLOOR PLAN SHEET | | | A1.01 HAS A NOTE STATING THAT ONE EXIT IS REQUIRED FROM | | | THE LOBBY. THE NOTE DOES NOT TAKE INTO ACCOUNT THE | | | NUMBER OF PEOPLE THAT WILL BE DISCHARGED INTO THE LOBBY | | | FROM STAIR 1. THE NOTE SHOULD BE CORRECTED. | | | | | | 7. GREASE INTERCEPTOR. A GREASE INTERCEPTOR WILL BE | | | REQUIRED. PLEASE CONTACT JEFFREY ODOMS, UTILITIES O&M | | | SUPERINTENDENT, PUBLIC UTILITIES DEPARTMENT, FATS OILS | | | AND GREASE DIVISION, AT (561) 822-2172, OR BY EMAIL: | | | [email protected] | | | | | | 8. SEPARATE PERMITS REQUIRED. ALL APPLICABLE PERMITS | | | AND SUB-PERMITS MUST BE OBTAINED BEFORE COMMENCING THE | | | WORK. SEPARATE PERMITS, PLANS AND FEES, ARE REQUIRED | | | FOR SIGNS, SWIMMING POOLS AND SPAS, GAS SYSTEMS, | | | GENERATORS, FIRE ALARM SYSTEMS, FIRE SPRINKLER AND | | | OTHER FIRE SUPPRESSION SYSTEMS, GREASE INTERCEPTORS, | | | SITE LIGHTING, SITE LANDSCAPE, SITE IRRIGATION, ETC. | | | | | | 9. CONTRACTOR VEHICLE PARKING. PROPERTY OWNER AND | | | CONTRACTOR SHALL MAKE ARRANGEMENTS FOR PARKING OF | | | CONTRACTOR VEHICLES TO MINIMIZE THE IMPACT ON ALL | | | NEIGHBORING PROPERTIES. | | | | | | 10. PROTECTION OF NEIGHBORING PROPERTY. PROPERTY OWNER | | | AND CONTRACTOR SHALL PROTECT ALL NEIGHBORING PROPERTY, | | | INCLUDING VEHICLES, FROM DAMAGE OR DIRT CAUSED BY THE | | | CONSTRUCTION, AND SHALL NOTIFY THE OCCUPANTS OF | | | NEIGHBORING PROPERTIES ABOUT ALL STAGES OF CONSTRUCTION | | | THAT MAY AFFECT THE USE OF THEIR PROPERTY. | | | | | | 11. ART IN PUBLIC PLACES. THIS PROJECT WILL BE SUBJECT | | | TO ART IN PUBLIC PLACES (AIPP) ASSESSMENT. FOR ADVICE | | | ON THE PROVISION OF PUBLIC ARTWORK IN LIEU OF THE AIPP | | | ASSESSMENT, CONTACT SYBILLE WELTER, ART IN PUBLIC | | | PLACES COORDINATOR, AT (561) 822-1521, OR BY EMAIL: | | | [email protected] | | | | | | ROBERT BROWN | | | BUILDING OFFICIAL | | | TEL: 561 805 6652 | | | EMAIL: [email protected] | | | |
|
|
| Review Stop |
ENG - PPRC |
ENGINEERING - PPRC |
| Rev No |
2 |
Status |
P |
Date |
08-01-2019 |
|
|
Cont ID |
|
| Sent By |
rrossano |
Date |
08-01-2019 |
Time |
|
Rev Time |
0.00 |
| Received By |
rrossano |
Date |
08-01-2019 |
Time |
|
Sent To |
|
|
| Notes |
| 2019-08-01 10:03:22 | A MEETING WAS HELD AT CITY OF WPB ENGINEERING | | | DISCUSSING UTILITY DESIGN WITH MR. FITZGERALD OF KIMLEY | | | HORN AND CITY ENGINEERING AND O&M PERSONNEL. THE PPRC | | | SUBMITTAL Z19050019 IS PASSED WITH THE FOLLOWING | | | PROVISOS AS CONDITIONS FOR THE FORMAL ENGINEERING | | | SUBMITTAL: | | | | | | PROVIDE CCTV VIDEO OF EXISTING SANITARY SEWER ALONG | | | ENTIRE PROJECT FRONTAGE. | | | | | | PROVIDE UTILITY EASEMENTS TO ALLOW ACCESS FOR CITY | | | PERSONNEL TO PROPOSED UTILITIES INCLUDING WATER METERS. | | | | | | PER MARK HURLEY, CITY OF WPB PUBLIC UTILITIES FIELD | | | CUSTOMER SERVICE SUPERVISOR: | | | | | | THE BACKFLOW PREVENTERS ARE NOT SHOWING ON SHEET C6.00; | | | NOT SURE IF THEY ARE LABELED ON ANOTHER SHEET. ALL OF | | | THE DOMESTIC/GENERAL CONTAINMENT BACKFLOW PREVENTERS | | | NEED TO BE OUTSIDE, CANNOT BE LOCATED INSIDE BUILDING. | | | TO FACILITATE THAT, THE METER VAULT/SERVICE MAY NEED TO | | | MOVE A NUMBER OF FEET NORTH FROM CURRENT POSITION.THE 3 | | | INCH BACKFLOW PREVENTERS FOR THE 2 INCH METERS MAY ALSO | | | BE A TIGHT FIT. EOR SHOULD VERIFY HOW HE WILL MAKE IT | | | WORK. | | | | | | ADJUST NOTE FOR 6 INCH METER TO INCLUDE CITY OF WPB | | | STANDARD DETAIL WS-6.1. | | | | | | ADJUST NOTE FOR 2 INCH METER TO REMOVE REFERENCE TO "3 | | | INCH WATER SERVICE", AND TO ADD STANDARD DETAIL NOTES | | | WS-1 AND WS-7. | | | | | | IF FIRE MARSHAL REQUIRING DCDA IN BUILDING THEN | | | BACKFLOW COVENANT SUBMISSION WOULD BE REQUIRED BY | | | PROPERTY OWNERS BEFORE IT CAN PASS INSPECTION AS | | | DISCUSSED IN MEETING. | | | | | | PLEASE NOTE THAT THE ADJACENT DROP-OFF ON HIBISCUS ST. | | | WILL REQUIRE A FORMAL TRAFFIC ENGINEERING SUBMITTAL TO | | | ADDRESS PEDESTRIAN SAFETY AND ADA CONCERNS. | | | | | | FEEL FREE TO CONTACT US IF YOU HAVE ANY QUESTIONS, | | | THANKS. | | | | | | RICK ROSSANO | | | PROJECT COORDINATOR | | | ENGINEERING SERVICES DEPARTMENT | | | 401 CLEMATIS STREET, 4TH FLOOR | | | WEST PALM BEACH, FL 33401 | | | (MAILING ADDRESS: P.O. BOX 3366, ZIP 33402) | | | MAIN PHONE: (561) 822-1200 | | | DIRECT: (561) 494-1098 | | | FAX: (561) 494-1116 | | | MOBILE: (561) 246-9525 | | | EMAIL: [email protected] | | | WWW.WPB.ORG/ENGINEERING | | | | | | MANNY GONZALEZ | | | SENIOR ENGINEERING PROJECT COORDINATOR | | | ENGINEERING SERVICES DEPARTMENT | | | 401 CLEMATIS STREET, 4TH FLOOR | | | WEST PALM BEACH, FL 33401 | | | (MAILING ADDRESS: P.O. BOX 3366, ZIP 33402) | | | MAIN PHONE: (561) 822-1200 | | | DIRECT: (561) 494-1085 | | | FAX: (561) 494-1116 | | | MOBILE: (561) 644-7301 | | | EMAIL: [email protected] | | | WWW.WPB.ORG/ENGINEERING | | | | | | CENTRAL OPERATIONS CENTER (DISPATCH): | | | 24-HOUR EMERGENCY RESPONSE SERVICES TO PUBLIC | | | UTILITIES, PUBLIC WORKS, PARKS, ETC. 561-822-2210 | | | | | | | | | | | | | | | |
|
|
| Review Stop |
ENG - PPRC |
ENGINEERING - PPRC |
| Rev No |
1 |
Status |
F |
Date |
06-07-2019 |
|
|
Cont ID |
|
| Sent By |
rrossano |
Date |
06-07-2019 |
Time |
|
Rev Time |
2.00 |
| Received By |
rrossano |
Date |
06-07-2019 |
Time |
|
Sent To |
|
|
| Notes |
| 2019-06-07 07:20:10 | PROVIDE CCTV VIDEO OF EXISTING SANITARY SEWER ALONG | | | ENTIRE PROJECT FRONTAGE. | | | | | | PLEASE SUBMIT A FORMAL AS-BUILT REQUEST FOR ALL CITY OF | | | WEST PALM BEACH-OWNED UTILITIES WITHIN THE PUBLIC RIGHT | | | OF WAY FOR THE ENTIRE EXTENT OF THE LIMITS OF YOUR | | | PROJECT. IDENTIFY TYPE OF UTILITY, LOCATION, PIPE | | | MATERIAL, AGE AND SIZE. PLEASE CONTACT JANICE TARBILL | | | IN THE WPB ENGINEERING SERVICES DEPARTMENT AT | | | [email protected] OR 561-494-1079 FOR FURTHER | | | ASSISTANCE. NOTE THAT FIELD RECORDS ARE FOR INFORMATION | | | ONLY. FIELD VERIFY UTILITY LOCATIONS USING FIELD | | | SURVEY, POT-HOLING, SOFT DIGS ETC. | | | | | | AS OF DECEMBER 20, 2015, THE CITY OF WEST PALM BEACH | | | CROSS-CONNECTION CONTROL MANUAL HAS BEEN REVISED, | | | STATING "ALL BACKFLOW DEVICES MUST BE LEAD-FREE". FOR | | | MORE INFORMATION, REFER TO THE LINK BELOW: | | | HTTP://WPB.ORG/DEPARTMENTS/PUBLIC-UTILITIES/FORMS-PUBLI | | | CATIONS/BACKFLOW-CROSS-CONNECTION-CONTROL-MANUAL | | | | | | PLANS SHALL SHOW PROPOSED LOCATIONS AND DIMENSIONS OF | | | ALL WATER, STORMWATER, AND SANITARY AND SEWER LINES, | | | INCLUDING STUBS TO EACH PROPERTY LINE FOR WATER AND | | | SANITARY SEWERS, THE MAKE AND MODEL OF ALL VALVES, | | | METERS, AND OTHERS DEVICES TO BE INSTALLED ON THE | | | SYSTEM, CATCH BASINS, CULVERTS, DITCHES INCLUDING | | | GRADES, PIPES SIZES, MATERIALS, ELEVATIONS, | | | ASSUMPTIONS, CALCULATIONS, INVERT ELEVATIONS FOR ALL | | | INLETS AND MANHOLES AND PROFILES OF SANITARY SEWER | | | LINES. ALL AVAILABLE ELEVATION SHALL BE SHOWN ON THE | | | PROFILE VIEW. DIRECTION OF FLOW SHALL BE SHOWN ON PLAN | | | VIEW ON PLAN VIEW FOR ALL SANITARY AND STORM SEWERS. | | | ADDITIONALLY, PLAN VIEW SHALL SHOW ALL EXISTING AND | | | PROPOSED UNDERGROUND UTILITY LAYOUT, INCLUDING FIBER | | | OPTIC, ELECTRIC, GAS, AND CABLEVISION & | | | TELECOMMUNICATION FACILITIES LOCATED ON THE | | | RIGHT-OF-WAY. PROVIDE PROFILE AND CLEARANCES AT ALL | | | UTILITY CROSSINGS. | | | | | | CUT AND CAP UTILITIES NOT IN USE, AND REMOVE ANY | | | ABANDONED UTILITY LINES LARGER THAN 2 INCHES FROM CITY | | | RIGHT OF WAY. | | | | | | PLEASE SUBMIT COMPLETED LOS ANALYSIS SUMMARY TABLE | | | DIRECTLY TO ENGINEERING (SHEET 33 OF CITY OF WPB | | | DEVELOPMENT APPLICATION). | | | | | | PLEASE PROVIDE CALCULATIONS OF REVISED PERVIOUS AND | | | IMPERVIOUS CALCULATIONS FOR THE PROPOSED IMPACTED | | | AREAS. | | | | | | PROVIDE ONSITE CLEANOUTS AT PROPERTY LINE FOR PROPOSED | | | SANITARY LATERALS. | | | | | | PROVIDE UTILITY EASEMENTS TO ALLOW ACCESS FOR CITY | | | PERSONNEL TO PROPOSED UTILITIES INCLUDING WATER METERS. | | | | | | DELINEATE CITY OF WPB UTILITY EASEMENTS AND/OR RIGHTS | | | OF WAY. PLEASE BOLD THE 25' ACCESS & UTILITY EASEMENT | | | ON SHEET C6. | | | | | | PROVIDE ENLARGED DETAIL ON PLANS OF PROPOSED LOCATION | | | OF WATER METER AND BACKFLOW PREVENTION. | | | | | | | | | THE FOLLOWING COMMENTS ARE FROM MARK HURLEY, FIELD | | | CUSTOMER SERVICE SUPERVISOR, PUBLIC UTILITIES, CITY OF | | | WEST PALM BEACH, 561-822-2262 | | | | | | SHEET P1.01: | | | | | | -BACKFLOW PREVENTERS ARE LABELED AS INDOORS. SHOULD NOT | | | BE INDOORS, SHOULD BE OUTSIDE CLOSE TO WATER SERVICE AS | | | POSSIBLE ON PRIVATE PROPERTY OUTSIDE OF ROW/UE. | | | | | | -ALL OF THE BACKFLOW PREVENTERS ARE MARKED AS DOUBLE | | | CHECK. THEY SHOULD BE RPZ. | | | | | | -VERTICAL INSTALLATION MAY NOT BE USC APPROVED OR | | | MANUFACTURER APPROVED FOR THE ASSEMBLY THEY ARE | | | INSTALLING. WOULD EITHER NEED FIND APPROVED-ASSEMBLY OR | | | CHANGE INSTALLATION TO HORIZONTAL. | | | | | | -DID NOT SEE FIRELINE DCDAS ON PLAN? NOT SURE IF THEY | | | ARE SHOWN ON THEIR UTILITY PLAN INSTEAD? I THINK THERE | | | ARE SOME EXISTING ONES ON SITE.. THEY SHOULD PUT ON | | | PLANS WITH THE EXISTING WATER SERVICES AND SHOW | | | CONNECTION/DESIGN/ETC. IF THEY FORGOT TO DRAW THE DCDA, | | | THEN THEY SHOULD RE-DRAW & LABEL. THEY CANNOT USE THE | | | DOMESTIC WATER SERVICES FOR FIRE WATER USES SUCH AS | | | FIRE SPRINKLERS. | | | | | | -FIELD CUSTOMER SERVICE RECOMMENDS CUSTOMERS INSTALL | | | PARALLEL BACKFLOW PREVENTERS SO CUSTOMERS STILL HAVE | | | WATER DURING BACKFLOW MAINTENANCE OR PROBLEMS.PLEASE | | | SEE SINGLE INSTALLATION HERE, DON'T KNOW IF THEY | | | CONSIDERED DOING THAT. | | | | | | -CAN'T TELL IF METER BOXES/VAULTS ARE IN GRASS AND | | | WHERE PROPERTY LINE AND UES ARE FROM DRAWING. PREFER | | | BOXES IN GRASS AND OUT OF SIDEWALKS.SHOULD BE IN | | | UE/ROW/PARKWAY. | | | | | | SHEET C6.00: | | | | | | -METER BOXES AND VAULTS APPEAR TO BE IN SIDEWALK. | | | THAT'S A SAFETY HAZARD AND ALSO HAVE TO CLOSE SIDEWALK | | | DURING METER MAINTENANCE. BOXES AND LIDS SHOULD BE | | | LOCATED OUT OF SIDEWALKS. CUSTOMER NEEDS TO DEVELOP | | | AREA PREFERABLY WITH GRASS BETWEEN SIDEWALKS AND | | | BUILDING WHERE VAULTS AND METER BOXES CAN LIE AND WON'T | | | BE WALKED ON IN REGULAR TRAFFIC PATHS. THEY CAN | | | SET-BACK OR REDESIGN BUILDING FOOTPRINT IF NEEDED AND | | | CREATE UTILITY EASEMENT. | | | | | | -ALL OF EXISTING UTILITIES NOT SHOWN. IN OUR BILLING | | | SYSTEM I SEE EXISTING 3 IN. METER AND 8 IN. FIRELINE | | | WITH DETECTOR METER. | | | | | | -8 IN. FIRELINE DCDA ARE PRETTY BIG. ON THE UTILITY | | | DRAWING IT DOES NOT SHOW THE FOOTPRINT AND EXACT | | | LOCATION OF PROP 8 IN. DCDA. CUSTOMER MAY HAVE | | | DIFFICULTY FITTING THERE. THIS MAY REQUIRE SPECIAL | | | PROTECTION IF LOCATED ADJACENT OUTSIDE WALL BY FIRE | | | DEPARTMENT. | | | | | | -CUSTOMER PROPERTY LINE NOT SHOWING IN ALLEY -> NOT | | | SURE IF PRIVATELY OWNED ROAD? -> UTILITY EASEMENT MAY | | | NEED BE ASSIGNED TO ALL THE WATER UTILITY MAIN, | | | SERVICE, AND METERS BOXES. | | | | | | -STANDARD DETAILS REFERENCES NOT SHOWN AND LABELED BY | | | CITY WPB WSD# | | | | | | -VAULT IS FAR FROM EXISTING CONNECTION -> ADDITIONAL | | | WATER SERVICE PIPING BEFORE VAULT SHOULD BE MINIMIZED. | | | | | | | | | FEEL FREE TO CONTACT US IF YOU HAVE ANY QUESTIONS OR | | | CONCERNS, THANKS. | | | | | | RICK ROSSANO | | | PROJECT COORDINATOR | | | ENGINEERING SERVICES DEPARTMENT | | | 401 CLEMATIS STREET, 4TH FLOOR | | | WEST PALM BEACH, FL 33401 | | | (MAILING ADDRESS: P.O. BOX 3366, ZIP 33402) | | | MAIN PHONE: (561) 822-1200 | | | DIRECT: (561) 494-1098 | | | FAX: (561) 494-1116 | | | MOBILE: (561) 246-9525 | | | EMAIL: [email protected] | | | WWW.WPB.ORG/ENGINEERING | | | | | | MANNY GONZALEZ | | | SENIOR ENGINEERING PROJECT COORDINATOR | | | ENGINEERING SERVICES DEPARTMENT | | | 401 CLEMATIS STREET, 4TH FLOOR | | | WEST PALM BEACH, FL 33401 | | | (MAILING ADDRESS: P.O. BOX 3366, ZIP 33402) | | | MAIN PHONE: (561) 822-1200 | | | DIRECT: (561) 494-1085 | | | FAX: (561) 494-1116 | | | MOBILE: (561) 644-7301 | | | EMAIL: [email protected] | | | WWW.WPB.ORG/ENGINEERING | | | | | | CENTRAL OPERATIONS CENTER (DISPATCH): | | | 24-HOUR EMERGENCY RESPONSE SERVICES TO PUBLIC | | | UTILITIES, PUBLIC WORKS, PARKS, ETC. 561-822-2210 | | | | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
05-31-2019 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
05-31-2019 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
05-31-2019 |
Time |
12:33 |
Sent To |
|
|
| Notes |
| 2019-05-31 12:35:11 | THE FOLLOWING COMMENTS WERE SUBMITTED BY PETER LEDUC, | | | FIRE MARSHAL, BUREAU OF FIRE PREVENTION, WEST PALM | | | BEACH FIRE RESCUE. | | | | | | THIS REVIEW CAN ONLY BE CONSIDERED PRELIMINARY AS THE | | | DRAWINGS THAT WERE REVIEWED WERE NOT COMPLETE. | | | ADDITIONAL COMMENTS CAN BE EXPECTED WHEN FULL DRAWINGS | | | ARE SUBMITTED FOR PERMIT. | | | | | | THE FIRE PREVENTION BUREAU HAS NO OBJECTIONS TO THE | | | PROPOSED PROJECT. | | | | | | 1. CONSTRUCTION, DEMOLITION, AND RENOVATION TO COMPLY | | | WITH NFPA 241. EXTRA ATTENTION SHALL BE GIVEN TO THE | | | PERMITTING AND LOCATION OF CONSTRUCTION TRAILERS. A | | | PERMIT IS REQUIRED FOR ANY CONSTRUCTION TRAILER RELATED | | | TO THIS PROJECT. SEPARATION DISTANCES FROM MAIN | | | STRUCTURES AS WELL AS OTHER TRAILERS SHALL BE CLOSELY | | | MONITORED FOR THE REQUIREMENTS OF FIRE SPRINKLER | | | PROTECTION. | | | | | | 2. SITE ACCESS AND EXIT POINTS ARE TO BE CLEARLY | | | IDENTIFIED AND MAINTAINED FOR EMERGENCY VEHICLES DURING | | | ALL CONSTRUCTION ACTIVITIES. | | | | | | 3. THE BUILDING ADDRESS SHALL BE CLEARLY VISIBLE FROM | | | ALL ACCESS ROADWAYS, INCLUDING DURING CONSTRUCTION. | | | ADDRESS NUMBERS SHALL CONTRAST WITH THEIR BACKGROUND | | | AND SHALL NOT BE LESS THAN SIX (6) INCHES IN HEIGHT | | | WITH A ONE (1) INCH STROKE FOR ALL BUILDINGS. | | | | | | 4. DURING CONSTRUCTION, TRASH AND DEBRIS IS TO BE | | | REMOVED FROM THE SITE DAILY OR MORE OFTEN TO REDUCE THE | | | ACCUMULATION OF POTENTIAL LIFE AND FIRE SAFETY HAZARDS. | | | | | | 5. THE CONSTRUCTION OF THE BUILDING SHALL COMPLY WITH | | | THE 6TH EDITION OF THE FLORIDA FIRE PREVENTION CODE, | | | INCLUDING NFPA 1 & 101, AND ALL ASSOCIATED FIRE CODES. | | | | | | 6. ALL PARKING STRUCTURES SHALL COMPLY WITH NFPA 88A, | | | PARKING STRUCTURES AND NFPA 101, THE LIFE SAFETY CODE, | | | INCLUDING MORE SPECIFICALLY, CHAPTER 42 STORAGE | | | OCCUPANCIES (PARKING STRUCTURES) | | | | | | 7. A NFPA 13 COMPLAINT FIRE SPRINKLER SYSTEM AND NFPA | | | 14 COMPLIANT WET STANDPIPE SYSTEM ARE REQUIRED FOR THIS | | | STRUCTURE. TEMPORARY STANDPIPES ARE REQUIRED WHEN THE | | | BUILDING REACHES THREE LEVELS OR THIRTY FEET WHILE | | | BEING CONSTRUCTED. | | | | | | SEPARATE SHOP DRAWINGS, ARE REQUIRED TO BE SUBMITTED, | | | REVIEWED AND APPROVED BY THE FIRE PREVENTION BUREAU | | | PRIOR TO ANY INSTALLATION. | | | | | | 6.4.5.4* FIRE DEPARTMENT CONNECTIONS SHALL BE LOCATED | | | NOT MORE THAN 100 FT (30.5 M) FROM THE NEAREST FIRE | | | HYDRANT CONNECTED TO AN APPROVED WATER SUPPLY. | | | | | | 18.3 WATER SUPPLIES. | | | 18.3.1* AN APPROVED WATER SUPPLY CAPABLE OF SUPPLYING | | | THE REQUIRED FIRE FLOW FOR FIRE PROTECTION SHALL BE | | | PROVIDED TO ALL PREMISES UPON WHICH FACILITIES, | | | BUILDINGS, OR PORTIONS OF BUILDINGS ARE HEREAFTER | | | CONSTRUCTED OR MOVED INTO THE JURISDICTION. THE | | | APPROVED WATER SUPPLY SHALL BE IN ACCORDANCE WITH | | | SECTION 18.4. | | | | | | THE LOCATION OF THE DDCV COULD NOT BE IDENTIFIED OF | | | SHEET F 1.01. THE LOCATION OF THE DDCV SHALL BE CLOSELY | | | COORDINATED WITH THE OFFICE OF THE FIRE MARSHAL, | | | ENGINEERING, ZONING AND THE LANDSCAPE PLANNER. | | | | | | PER NFPA 14 SECTION 7.12.2, HIGH-RISE BUILDINGS SHALL | | | HAVE AT LEAST TWO REMOTELY LOCATED FIRE DEPARTMENT | | | CONNECTIONS FOR EACH ZONE. | | | | | | PER FLORIDA ADMINISTRATIVE CODE SECTION 61G15-32.004, | | | FIRE PROTECTION ENGINEERING DOCUMENTS SHALL INCLUDE THE | | | POINT OF SERVICE FOR THE WATER SUPPLY, A LIST OF | | | APPLICABLE NFPA STANDARDS APPLICABLE TO THE PROJECT, | | | CLASSIFICATION OF HAZARD OCCUPANCY FOR EACH ROOM OR | | | AREA, SUPPRESSION SYSTEM TYPE, DESIGN DENSITIES, WATER | | | SUPPLY DATA (FIRE PUMP DATA, HYDRANT FLOW TEST DATA) | | | AND ANY PERFORMANCE BASED INFORMATION SUCH AS | | | PRE-ENGINEERED SYSTEMS. | | | FOR THE PROPOSED FIRE PUMP(S) , WHAT IS(ARE) THE | | | PRIMARY AND SECONDARY POWER SOURCES? | | | | | | 8. A CLASS A NFPA 72 COMPLIANT MONITORED FIRE ALARM | | | SYSTEM IS REQUIRED FOR THIS STRUCTURE. SEPARATE SHOP | | | DRAWINGS, ARE REQUIRED TO BE SUBMITTED, REVIEWED AND | | | APPROVED BY THE FIRE PREVENTION BUREAU PRIOR TO ANY | | | INSTALLATION. | | | | | | 9. ALL ELEVATORS SHALL BE EQUIPPED WITH A REGION 7 | | | KEYWAY SYSTEM. | | | | | | ALL NEW ELEVATORS SHALL CONFORM TO THE FIRE FIGHTERS | | | EMERGENCY OPERATIONS REQUIREMENTS OF ASME A17.1/CSA | | | B44, SAFETY CODE FOR ELEVATORS. | | | ANY BUILDING THAT IS MORE THAN THREE STORIES HIGH OR IN | | | WHICH THE VERTICAL DISTANCE BETWEEN THE BOTTOM TERMINAL | | | LANDING AND THE TOP TERMINAL LANDING EXCEEDS 25 FEET | | | MUST BE CONSTRUCTED TO CONTAIN AT LEAST ONE PASSENGER | | | ELEVATOR THAT IS OPERATIONAL AND WILL ACCOMMODATE AN | | | AMBULANCE STRETCHER 76 INCHES LONG AND 24 INCHES WIDE | | | IN THE HORIZONTAL POSITION. | | | | | | 10. COMPLETE LIFE SAFETY PLANS FOR EACH OCCUPANCY SHALL | | | BE PROVIDED THAT ILLUSTRATE OCCUPANT LOADS, TRAVEL | | | DISTANCES, COMMON PATHS OF TRAVEL, DEAD-END CORRIDORS, | | | EXIT SIGNS, EMERGENCY LIGHTING, EXITS LEADING TO A | | | PUBLIC WAY, FIRE EXTINGUISHER LOCATIONS, AND ALL FIRE | | | SAFETY FEATURES AND EQUIPMENT. | | | | | | 11. ALL EXISTING AND NEW FIRE HYDRANTS PLANNED FOR THIS | | | DEVELOPMENT SHALL BE CLEARLY INDICATED AND IDENTIFIED | | | ON THE PLAN AND CLOSELY COORDINATED WITH THE BUREAU OF | | | FIRE PREVENTION. | | | | | | ALL NEW FIRE HYDRANTS AND FDCS PLANNED FOR THIS | | | DEVELOPMENT SHALL BE CLOSELY COORDINATED WITH THE | | | BUREAU OF FIRE PREVENTION. PROPOSED FIRE HYDRANTS AND | | | FDCS SHOULD BE LOCATED ON THE SAME SIDE OF THE STREET | | | OR ACCESS ROADWAY TO ALLOW FREE ACCESS FOR OTHER | | | ARRIVING EMERGENCY VEHICLES. | | | | | | TWO (2) SEPARATE FDCS ARE REQUESTED FOR THIS HIGH RISE, | | | SEPARATE FROM EACH OTHER, FOR EFFECTIVE AND EFFICIENT | | | FIREGROUND OPERATIONS. THE LOCATION SHOULD BE | | | COORDINATED THROUGH THE OFFICE OF THE FIRE MARSHAL. | | | | | | 12. COMMAND ROOM | | | | | | THE FIRE COMMAND CENTER SHALL COMPLY WITH NFPA 1, | | | CHAPTER 11, BUILDING SERVICES; 11.9 AND SHALL CONTAIN | | | THE FOLLOWING FEATURES: | | | | | | A. SHALL BE A MINIMUM OF 200 FT SQUARED WITH A MINIMUM | | | DIMENSION OF 10 FT. | | | B. THE FIRE DEPARTMENT COMMUNICATIONS SYSTEM. | | | C. A TELEPHONE FOR FIRE DEPARTMENT USE WITH CONTROLLED | | | ACCESS TO THE PUBLIC TELEPHONE SYSTEM | | | D. SCHEMATIC BUILDING PLANS INDICATING THE TYPICAL | | | FLOOR PLAN AND DETAILING THE BUILDING CORE, MEANS OF | | | EGRESS, FIRE PROTECTION SYSTEMS, FIRE-FIGHTING | | | EQUIPMENT AND FIRE DEPARTMENT ACCESS AND THE LOCATION | | | OF FIRE WALLS, FIRE BARRIERS, FIRE PARTITIONS, SMOKE | | | BARRIERS AND SMOKE PARTITIONS | | | E. A WORK TABLE. | | | F. IF APPLICABLE, A HAZARDOUS MATERIAL MANAGEMENT PLAN | | | FOR THE BUILDING. | | | G. THE EMERGENCY VOICE/ALARM COMMUNICATION SYSTEM | | | CONTROL UNIT. | | | H. ANNUNCIATOR UNIT VISUALLY INDICATING THE LOCATION OF | | | THE ELEVATORS AND WHETHER THEY ARE OPERATIONAL | | | I. STATUS INDICATORS AND CONTROLS FOR AIR DISTRIBUTION | | | SYSTEMS. | | | J. CONTROLS FOR UNLOCKING STAIRWAY DOORS SIMULTANEOUSLY | | | K. SPRINKLER VALVE AND WATER FLOW DETECTOR DISPLAY | | | PANELS | | | L. EMERGENCY AND STANDBY POWER STATUS INDICATORS | | | M. FIRE PUMP STATUS INDICATORS | | | N. GENERATOR SUPERVISION DEVICES AND MANUAL START AND | | | TRANSFER FEATURES. | | | O. PUBLIC ADDRESS SYSTEM, WHERE SPECIFICALLY REQUIRED | | | BY OTHER SECTIONS OF THIS CODE | | | P. CONTROLS REQUIRED FOR SMOKE CONTROL | | | Q. ELEVATOR FIRE RECALL SWITCH IN ACCORDANCE WITH ASME | | | A17.1. | | | R. ELEVATOR EMERGENCY OR STANDBY POWER SELECTOR | | | SWITCH(ES), WHERE EMERGENCY OR STANDBY POWER IS | | | PROVIDED | | | | | | 11.8.6* EMERGENCY COMMAND CENTER. | | | 11.8.6.1 AN EMERGENCY COMMAND CENTER SHALL BE PROVIDED | | | IN A | | | LOCATION APPROVED BY THE FIRE DEPARTMENT. | | | 11.8.6.2 THE EMERGENCY COMMAND CENTER SHALL CONTAIN THE | | | FOLLOWING: | | | (1) VOICE FIRE ALARM SYSTEM PANELS AND CONTROLS | | | (2) FIRE DEPARTMENT TWO-WAY TELEPHONE COMMUNICATION | | | SERVICE | | | PANELS AND CONTROLS WHERE REQUIRED BY ANOTHER SECTION | | | OF THIS | | | CODE | | | (3) FIRE DETECTION AND FIRE ALARM SYSTEM ANNUNCIATION | | | PANELS | | | (4) ELEVATOR FLOOR LOCATION AND OPERATION ANNUNCIATORS | | | (5) ELEVATOR FIRE RECALL SWITCH IN ACCORDANCE WITH ASME | | | A17.1/CSA B44, SAFETY CODE FOR ELEVATORS AND ESCALATORS | | | (6) ELEVATOR EMERGENCY POWER SELECTOR SWITCH(ES) WHERE | | | PROVIDED | | | IN ACCORDANCE WITH ASME A17.1/CSA B44 | | | (7) SPRINKLER VALVE AND WATERFLOW ANNUNCIATORS | | | (8) EMERGENCY GENERATOR STATUS INDICATORS | | | (9) CONTROLS FOR ANY AUTOMATIC STAIRWAY DOOR UNLOCKING | | | SYSTEM | | | (10) FIRE PUMP STATUS INDICATORS | | | (11) TELEPHONE FOR FIRE DEPARTMENT USE WITH CONTROLLED | | | ACCESS TO THE | | | PUBLIC TELEPHONE SYSTEM | | | (12) STAIRWAY VIDEO MONITORING EQUIPMENT AS REQUIRED BY | | | 11.8.8 | | | | | | 13. RADIO | | | | | | NFPA 1, CHAPTER 11, BUILDING SERVICES; 11.10 TWO-WAY | | | RADIO ENHANCEMENT SERVICES. | | | | | | 11.10.1 IN ALL NEW AND EXISTING BUILDINGS, MINIMUM | | | RADIO SIGNAL STRENGTH FOR FIRE DEPARTMENT | | | COMMUNICATIONS SHALL BE MAINTAINED AT A LEVEL | | | DETERMINED BY THE AHJ. | | | | | | NFPA 72, 24.5.2* TWO-WAY RADIO COMMUNICATIONS | | | ENHANCEMENT SYSTEMS. | | | 24.5.2.2 RADIO COVERAGE. RADIO COVERAGE SHALL BE | | | PROVIDED THROUGHOUT THE BUILDING AS A PERCENTAGE OF | | | FLOOR AREA AS SPECIFIED IN 24.5.2.2.1 THROUGH | | | 24.5.2.2.3. | | | 24.5.2.2.1 CRITICAL AREAS. CRITICAL AREAS, SUCH AS THE | | | EMERGENCY COMMAND CENTER(S), THE FIRE PUMP ROOM(S), | | | EXIT STAIRS, EXIT PASSAGEWAYS, ELEVATOR LOBBIES, | | | STANDPIPE CABINETS, SPRINKLER SECTIONAL VALVE | | | LOCATIONS, AND OTHER AREAS DEEMED CRITICAL BY THE | | | AUTHORITY HAVING JURISDICTION, SHALL BE PROVIDED WITH | | | 99 PERCENT FLOOR AREA RADIO COVERAGE. | | | 24.5.2.2.2 GENERAL BUILDING AREAS. GENERAL BUILDING | | | AREAS SHALL BE PROVIDED WITH 90 PERCENT FLOOR AREA | | | RADIO COVERAGE. | | | 24.5.2.3 SIGNAL STRENGTH. | | | 24.5.2.3.1 INBOUND. A MINIMUM INBOUND SIGNAL STRENGTH | | | OF -95 DBM, OR OTHER SIGNAL STRENGTH AS REQUIRED BY THE | | | AUTHORITY HAVING JURISDICTION, SHALL BE PROVIDED | | | THROUGHOUT THE COVERAGE AREA. | | | 24.5.2.3.2 OUTBOUND. A MINIMUM OUTBOUND SIGNAL STRENGTH | | | OF -95 DBM AT THE DONOR SITE, OR OTHER SIGNAL STRENGTH | | | AS REQUIRED BY THE AUTHORITY HAVING JURISDICTION, SHALL | | | BE PROVIDED FROM THE COVERAGE AREA. | | | | | | THE SYSTEM SHALL MAINTAIN A MINIMUM RADIO SIGNAL | | | STRENGTH OF -95 DBM FOR THE RADIO SYSTEM USED BY WEST | | | PALM BEACH FIRE RESCUE. TESTING SHALL BE BY AN | | | ACCEPTABLE NATIONAL STANDARD DOCUMENTING PERCENTAGES | | | NOTED ABOVE AND BY ACTUAL RADIO TESTING BY FIRE | | | PERSONNEL. IF THE MINIMUM CANNOT BE MAINTAINED, A | | | BI-DIRECTIONAL AMPLIFIED SYSTEM SHALL BE INSTALLED WITH | | | A MINIMUM 2-HOUR RUN TIME BATTERY BACK-UP. | | | | | | 14. KNOX-BOX KEY SYSTEM SHALL BE REQUIRED FOR THIS | | | BUILDING. | | | ANY GATES SHALL BE PROVIDED WITH KNOX KEY ACCESS LOCKS, | | | PADLOCKS AND/OR SWITCHES FOR 24 HOUR EMERGENCY ACCESS. | | | | | | 15. THE SMOKE CONTROL SYSTEM SHALL COMPLY WITH NFPA | | | 101, CHAPTER 9, BUILDING SERVICE AND FIRE PROTECTION | | | EQUIPMENT, INCLUDING: | | | | | | THE SMOKE CONTROL SYSTEMS SHALL BE INSTALLED, | | | INSPECTED, TESTED, AND MAINTAINED IN ACCORDANCE WITH | | | NFPA 92, STANDARD FOR SMOKE CONTROL SYSTEMS; NFPA 204, | | | STANDARD FOR SMOKE AND HEAT VENTING; OR NATIONALLY | | | RECOGNIZED STANDARDS, ENGINEERING GUIDES, OR | | | RECOMMENDED PRACTICES, AS APPROVED BY THE AUTHORITY | | | HAVING JURISDICTION. | | | | | | THE ENGINEER OF RECORD SHALL CLEARLY IDENTIFY THE | | | INTENT OF THE SYSTEM, THE DESIGN METHOD USED, THE | | | APPROPRIATENESS OF THE METHOD USED, AND THE REQUIRED | | | MEANS OF INSPECTING, TESTING, AND MAINTAINING THE | | | SYSTEM. | | | | | | ACCEPTANCE TESTING SHALL BE PERFORMED BY A SPECIAL | | | INSPECTOR IN ACCORDANCE WITH SECTION 9.9. | | | | | | | | | 16. FOR BUILDING PLAN REVIEWDICUSSION PURPOSES THE | | | STAIRWAY EXIT DISCHARGE LOCATED AT THE CENTER OF THE | | | BUILDING THROUGH THE ASSEMBLY SEATING AREA REMAINS A | | | CONCERN. THE CODE WILL ALLOW THE EXIT THROUGH CERTAIN | | | AREAS; HOWEVER, THE ASSEMBLY SEATING AREA DOES NOT | | | APPEAR TO BE ONE OF THOSE AREAS. | | | | | | 7.1.3.2.2 AN EXIT ENCLOSURE SHALL PROVIDE A CONTINUOUS | | | PROTECTED | | | PATH OF TRAVEL TO AN EXIT DISCHARGE. | | | | | | 3.3.85 EXIT DISCHARGE. THAT PORTION OF A MEANS OF | | | EGRESS BETWEEN | | | THE TERMINATION OF AN EXIT AND A PUBLIC WAY. | | | | | | 7.7 DISCHARGE FROM EXITS. | | | | | | 7.7.1.1 YARDS, COURTS, OPEN SPACES, OR OTHER PORTIONS | | | OF THE EXIT | | | DISCHARGE SHALL BE OF THE REQUIRED WIDTH AND SIZE TO | | | PROVIDE ALL | | | OCCUPANTS WITH A SAFE ACCESS TO A PUBLIC WAY. | | | | | | A 5' AREA IS INDICATED ALONG THE WALL; HOWEVER, HOW | | | WILL THIS AREA BE MAINTAINED/SEPARATED FOR THE SEATING. | | | WHAT IS TO STOP ANYONE FROM MOVING TABLE AND CHAIRS | | | INTO THIS EXT TRAVEL PATH? | | | | | | THE PPRC PLAN WILL BE APPROVED AND THIS AREA CAN BE | | | ADDRESSED WITH BUILDING PLAN SUBMITTALS. | | | | | | 17) THE BUREAU'S APPROVAL OF THIS SUBMITTED PROJECT | | | DOES NOT CONSTITUTE IT'S FINAL REVIEW OR APPROVAL. | | | | | | | | | 18). THE BUREAU SHALL REVIEW ALL SUBMITTED BUILDING | | | PLANS AT THE APPROPRIATE TIME AND IN ACCORDANCE WITH | | | THE REQUIREMENTS OF ALL APPLICABLE CODES AND STANDARDS. | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
4 |
Status |
P |
Date |
10-22-2019 |
|
|
Cont ID |
|
| Sent By |
rcaranci |
Date |
10-22-2019 |
Time |
09:31 |
Rev Time |
0.00 |
| Received By |
rcaranci |
Date |
10-22-2019 |
Time |
09:31 |
Sent To |
|
|
| Notes |
| 2019-10-22 09:31:54 | FROM: RAY CARANCI, LANDSCAPE PLANNER 561-822-1462 | | | PROJECT: 575 ROSEMARY (MACY?S) Z19050019 | | | OCTOBER 15, 2019 | | | I HAVE REVIEWED THE ABOVE REFERENCED PETITION, AND | | | PROVIDE THE FOLLOWING COMMENTS: | | | | | | 1. MAKE THE FOLLOWING CORRECTIONS TO THE TREE | | | DISPOSITION PLAN: | | | ? SATISFIED. THE WASHINGTONIA PALMS ARE CATEGORY 4, | | | CANOPY VALUE IS 50 SQ FT. | | | ? SATISFIED. PROVIDE THE TOTAL SQUARE FOOTAGE OF | | | MITIGATION FOR ALL TREES AND PALMS PROPOSED TO BE | | | REMOVED. | | | ? SATISFIED. PROVIDE THE MITIGATION VALUES BY CATEGORY | | | FOR THE PROPOSED STREETSCAPE TREES AND PALMS. SEE | | | BELOW. | | | | | | 2. SATISFIED. THE STREETSCAPE CAN BE IMPROVED TO | | | ACCOMPLISH THE INTENT OF THE CODE SECTION 94-113. THE | | | COCONUT PALMS AND DATE PALMS MAY BE USED, BUT NOT AS | | | COUNTING TOWARD THE TREE REQUIREMENT AT THE MAXIMUM 30 | | | FOOT SPACING. THERE ARE ALSO CONFLICTS WITH PROPOSED | | | AWNING AND STREET TREES. | | | PLANNING STAFF HAS NOT REVIEWED OR APPROVED THE | | | STREETSCAPE PLANS FOR THE AREAS ADJACENT TO THIS | | | PROJECT. PROVIDE THE 100% PLANS FOR REVIEW. | | | 3. SATISFIED. REQUIRED STREET TREES MUST MEET THE 20 | | | FOOT HEIGHT REQUIREMENT AT INSTALLATION. LIST OVERALL | | | HEIGHT ON PLANT LIST. | | | PLANNING STAFF HAS NOT REVIEWED OR APPROVED THE | | | STREETSCAPE PLANS FOR THE AREAS ADJACENT TO THIS | | | PROJECT. PROVIDE THE 100% PLANS FOR REVIEW. | | | | | | 4. SATISFIED. SECTION 94-448 (D)(3) REQUIRES NATIVE | | | TREES IN GOOD CONDITION TO BE PRESERVED ON SITE OR | | | RELOCATED. SUBMIT THE REASON THE TWO EXISTING LIVE OAK | | | TREES CANNOT BE RELOCATED OR USED IN THE PROPOSED | | | STREETSCAPE. | | | PLANNING STAFF HAS NOT REVIEWED OR APPROVED THE | | | STREETSCAPE PLANS FOR THE AREAS ADJACENT TO THIS | | | PROJECT. PROVIDE THE 100% PLANS FOR REVIEW. | | | | | | | | | 5. SATISFIED. PUBLIC AND PRIVATE OPEN SPACE AREAS SHOWN | | | ON SHEET A0.05 MUST BE BROKEN DOWN TO SHOW THE REQUIRED | | | VEGETATED AREA AND ANY TREE CANOPY REQUIREMENT FOR EACH | | | AREA. PASSAGEWAY LESS THAN 7500 SQ FT REQUIRE ZERO ANY | | | OF EITHER. TERRACE REQUIRES 20% MINIMUM VEGETATED AREA. | | | ROOFTOP GARDEN REQUIRES 30% VEGETATED AREA AND 20% TREE | | | CANOPY. TREE CANOPY VALUES CAN BE FOUND IN SECTION | | | 94-109 TABLE IV-8. | | | | | | 6. SATISFIED. AREA LISTED AS POOL DECK ON LEVEL 3 IS | | | NOT AN OPEN SPACE TYPE. CLASSIFY AS A PERMITTED PRIVATE | | | OPEN SPACE TYPE (ROOFTOP GARDEN?) AND SHOW | | | REQUIREMENTS. | | | | | | 7. SATISFIED. ADD COLUMNS FOR NATIVE PLANTS AND DROUGHT | | | TOLERANCE/ WATER USAGE TO THE PLANT LIST SO THAT | | | FLORIDA FRIENDLY POINTS CAN BE SUBSTANTIATED. | | | | | | 8. SATISFIED. TRA IS MISSING FROM THE PLANT LIST. | | | | | | 9. SATISFIED. SHOW LOCATIONS OF ANY ROOT BARRIERS | | | REQUIRED TO PROTECT UTILITY LINES. | | | BIOBARRIER IS NOT ACCEPTABLE AS ROOT BARRIER, MUST BE | | | HARD PLASTIC ROOT BARRIER DEEP ROOT OR SIMILAR. | | | SOME ROOT BARRIER LOCATIONS SHOWN ARE NOT APPROPRIATE, | | | AS THEY SEPARATE THE ROOTS FROM REQUIRED SOIL AREAS. | | | PROVIDE A ROOT BARRIER DETAIL. | | | | | | 10. SATISFIED. SHOW COMPLIANCE WITH SECTION 94-445 L. | | | PLANT SPECIES. A MINIMUM OF 60 PERCENT OF PLANT | | | MATERIAL ADDED SHALL BE FLORIDA NATIVE OR DROUGHT | | | TOLERANT SPECIES SELECTED FROM THE CITY LIST OR THE | | | LIST OF SPECIES IN THE MOST RECENT EDITION OF SOUTH | | | FLORIDA WATER MANAGEMENT DISTRICT WATERWISE SOUTH | | | FLORIDA LANDSCAPES. | | | PROVIDE THE ACTUAL PERCENTAGE OF DROUGHT TOLERANT AND | | | NATIVE SPECIES ADDED BASED ON THE PROPOSED PLANT LIST. | | | | | | ADDITIONAL COMMENTS 8/16/19: | | | | | | 11. SATISFIED. PROVIDE THE 50 POINTS REQUIRED FROM THE | | | FLORIDA FRIENDLY DESIGN OPTIONS FOUND IN SECTION | | | 94-443(G). | | | | | | 12. SATISFIED. PER RESOLUTION NO. 304-18 UNDER 2. | | | CITYPLACE CENTER B., FOUR FICUS TREES WITHIN THE PAVED | | | AREAS NEED TO BE SHOWN WITH SUSPENDED PAVEMENT SYSTEM | | | FOR THE ROOT ZONES OF THE TREES. PROVIDE THE LOCATIONS | | | AND DETAIL FOR THE SYSTEM. | | | | | | CONDITIONS OF APPROVAL | | | 1. PRIOR TO THE REMOVAL OR RELOCATION OF ANY TREES ON | | | THE PROPERTY, A TREE ALTERATION PERMIT SHALL BE | | | SUBMITTED, REVIEWED AND APPROVED BY THE DEVELOPMENT | | | SERVICES DEPARTMENT, PLANNING DIVISION. | | | |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
3 |
Status |
F |
Date |
09-18-2019 |
|
|
Cont ID |
|
| Sent By |
rcaranci |
Date |
09-18-2019 |
Time |
17:21 |
Rev Time |
0.00 |
| Received By |
rcaranci |
Date |
09-18-2019 |
Time |
17:21 |
Sent To |
|
|
| Notes |
| 2019-09-18 17:22:08 | FROM: RAY CARANCI, LANDSCAPE PLANNER 561-822-1462 | | | PROJECT: 575 ROSEMARY (MACY?S) Z19050019 | | | SEPTEMBER 18, 2019 | | | I HAVE REVIEWED THE ABOVE REFERENCED PETITION, AND | | | PROVIDE THE FOLLOWING COMMENTS: | | | | | | 1. MAKE THE FOLLOWING CORRECTIONS TO THE TREE | | | DISPOSITION PLAN: | | | ? SATISFIED. THE WASHINGTONIA PALMS ARE CATEGORY 4, | | | CANOPY VALUE IS 50 SQ FT. | | | ? PARTIALLY SATISFIED. PROVIDE THE TOTAL SQUARE FOOTAGE | | | OF MITIGATION FOR ALL TREES AND PALMS PROPOSED TO BE | | | REMOVED. | | | OAKS ON GARDENIA NEED TO BE INCLUDED, AS THEY ARE IN | | | THE AREA OF STREETSCAPE REQUIRED TO BE INCLUDED WITH | | | THIS SITE. | | | ? SATISFIED. PROVIDE THE MITIGATION VALUES BY CATEGORY | | | FOR THE PROPOSED STREETSCAPE TREES AND PALMS. | | | | | | 2. PARTIALLY SATISFIED. THE STREETSCAPE CAN BE IMPROVED | | | TO ACCOMPLISH THE INTENT OF THE CODE SECTION 94-113. | | | THE COCONUT PALMS AND DATE PALMS MAY BE USED, BUT NOT | | | AS COUNTING TOWARD THE TREE REQUIREMENT AT THE MAXIMUM | | | 30 FOOT SPACING. THERE ARE ALSO CONFLICTS WITH PROPOSED | | | AWNING AND STREET TREES. | | | PLANNING STAFF HAS NOT REVIEWED OR APPROVED THE | | | STREETSCAPE PLANS FOR THE AREAS ADJACENT TO THIS | | | PROJECT. PROVIDE THE 100% PLANS FOR REVIEW. | | | A COURTESY REVIEW WAS CONDUCTED ON THE PLAN COPY | | | DELIVERED BY THE APPLICANT. A FORMAL SUBMITTAL WITH THE | | | PLANS INCORPORATED INTO THE LANDSCAPE PLAN FOR THIS | | | SITE IS REQUIRED FOR APPROVAL. AREAS OF STRUCTURAL SOIL | | | MUST BE SHOWN ON ROSEMARY SECTION. | | | | | | 3. SATISFIED. REQUIRED STREET TREES MUST MEET THE 20 | | | FOOT HEIGHT REQUIREMENT AT INSTALLATION. LIST OVERALL | | | HEIGHT ON PLANT LIST. | | | PLANNING STAFF HAS NOT REVIEWED OR APPROVED THE | | | STREETSCAPE PLANS FOR THE AREAS ADJACENT TO THIS | | | PROJECT. PROVIDE THE 100% PLANS FOR REVIEW. | | | | | | 4. SATISFIED. SECTION 94-448 (D)(3) REQUIRES NATIVE | | | TREES IN GOOD CONDITION TO BE PRESERVED ON SITE OR | | | RELOCATED. SUBMIT THE REASON THE TWO EXISTING LIVE OAK | | | TREES CANNOT BE RELOCATED OR USED IN THE PROPOSED | | | STREETSCAPE. | | | PLANNING STAFF HAS NOT REVIEWED OR APPROVED THE | | | STREETSCAPE PLANS FOR THE AREAS ADJACENT TO THIS | | | PROJECT. PROVIDE THE 100% PLANS FOR REVIEW. | | | | | | | | | 5. PARTIALLY SATISFIED. PUBLIC AND PRIVATE OPEN SPACE | | | AREAS SHOWN ON SHEET A0.05 MUST BE BROKEN DOWN TO SHOW | | | THE REQUIRED VEGETATED AREA AND ANY TREE CANOPY | | | REQUIREMENT FOR EACH AREA. PASSAGEWAY LESS THAN 7500 SQ | | | FT REQUIRE ZERO ANY OF EITHER. TERRACE REQUIRES 20% | | | MINIMUM VEGETATED AREA. ROOFTOP GARDEN REQUIRES 30% | | | VEGETATED AREA AND 20% TREE CANOPY. TREE CANOPY VALUES | | | CAN BE FOUND IN SECTION 94-109 TABLE IV-8. | | | AREAS SHOWN MUST MEET THE DEFINITION FOR THE OPEN SPACE | | | TYPE IF THEY ARE TO BE COUNTED TOWARD REQUIRED OPEN | | | SPACE. ZONING COMMENTS WILL INCLUDE DETAILS. | | | | | | 6. SATISFIED. AREA LISTED AS POOL DECK ON LEVEL 3 IS | | | NOT AN OPEN SPACE TYPE. CLASSIFY AS A PERMITTED PRIVATE | | | OPEN SPACE TYPE (ROOFTOP GARDEN?) AND SHOW | | | REQUIREMENTS. | | | | | | 7. SATISFIED. ADD COLUMNS FOR NATIVE PLANTS AND DROUGHT | | | TOLERANCE/ WATER USAGE TO THE PLANT LIST SO THAT | | | FLORIDA FRIENDLY POINTS CAN BE SUBSTANTIATED. | | | | | | 8. SATISFIED. TRA IS MISSING FROM THE PLANT LIST. | | | | | | 9. SATISFIED. SHOW LOCATIONS OF ANY ROOT BARRIERS | | | REQUIRED TO PROTECT UTILITY LINES. | | | BIOBARRIER IS NOT ACCEPTABLE AS ROOT BARRIER, MUST BE | | | HARD PLASTIC ROOT BARRIER DEEP ROOT OR SIMILAR. | | | SOME ROOT BARRIER LOCATIONS SHOWN ARE NOT APPROPRIATE, | | | AS THEY SEPARATE THE ROOTS FROM REQUIRED SOIL AREAS. | | | PROVIDE A ROOT BARRIER DETAIL. | | | | | | 10. SATISFIED. SHOW COMPLIANCE WITH SECTION 94-445 L. | | | PLANT SPECIES. A MINIMUM OF 60 PERCENT OF PLANT | | | MATERIAL ADDED SHALL BE FLORIDA NATIVE OR DROUGHT | | | TOLERANT SPECIES SELECTED FROM THE CITY LIST OR THE | | | LIST OF SPECIES IN THE MOST RECENT EDITION OF SOUTH | | | FLORIDA WATER MANAGEMENT DISTRICT WATERWISE SOUTH | | | FLORIDA LANDSCAPES. | | | PROVIDE THE ACTUAL PERCENTAGE OF DROUGHT TOLERANT AND | | | NATIVE SPECIES ADDED BASED ON THE PROPOSED PLANT LIST. | | | | | | ADDITIONAL COMMENTS 8/16/19: | | | | | | 11. SATISFIED. PROVIDE THE 50 POINTS REQUIRED FROM THE | | | FLORIDA FRIENDLY DESIGN OPTIONS FOUND IN SECTION | | | 94-443(G). | | | | | | 12. SATISFIED. PER RESOLUTION NO. 304-18 UNDER 2. | | | CITYPLACE CENTER B., FOUR FICUS TREES WITHIN THE PAVED | | | AREAS NEED TO BE SHOWN WITH SUSPENDED PAVEMENT SYSTEM | | | FOR THE ROOT ZONES OF THE TREES. PROVIDE THE LOCATIONS | | | AND DETAIL FOR THE SYSTEM. | | | | | | CONDITIONS OF APPROVAL | | | 1. PRIOR TO THE REMOVAL OR RELOCATION OF ANY TREES ON | | | THE PROPERTY, A TREE ALTERATION PERMIT SHALL BE | | | SUBMITTED, REVIEWED AND APPROVED BY THE DEVELOPMENT | | | SERVICES DEPARTMENT, PLANNING DIVISION. | | | |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
2 |
Status |
F |
Date |
08-16-2019 |
|
|
Cont ID |
|
| Sent By |
rcaranci |
Date |
08-16-2019 |
Time |
14:31 |
Rev Time |
0.00 |
| Received By |
rcaranci |
Date |
08-16-2019 |
Time |
14:31 |
Sent To |
|
|
| Notes |
| 2019-08-16 14:31:49 | FROM: RAY CARANCI, LANDSCAPE PLANNER 561-822-1462 | | | PROJECT: 575 ROSEMARY (MACY?S) Z19050019 | | | AUGUST 16, 2019 | | | I HAVE REVIEWED THE ABOVE REFERENCED PETITION, AND | | | PROVIDE THE FOLLOWING COMMENTS: | | | | | | 1. MAKE THE FOLLOWING CORRECTIONS TO THE TREE | | | DISPOSITION PLAN: | | | ? SATISFIED. THE WASHINGTONIA PALMS ARE CATEGORY 4, | | | CANOPY VALUE IS 50 SQ FT. | | | ? PARTIALLY SATISFIED. PROVIDE THE TOTAL SQUARE FOOTAGE | | | OF MITIGATION FOR ALL TREES AND PALMS PROPOSED TO BE | | | REMOVED. | | | ? PARTIALLY SATISFIED. PROVIDE THE MITIGATION VALUES BY | | | CATEGORY FOR THE PROPOSED STREETSCAPE TREES AND PALMS. | | | SEE BELOW. | | | | | | 2. NOT SATISFIED. THE STREETSCAPE CAN BE IMPROVED TO | | | ACCOMPLISH THE INTENT OF THE CODE SECTION 94-113. THE | | | COCONUT PALMS AND DATE PALMS MAY BE USED, BUT NOT AS | | | COUNTING TOWARD THE TREE REQUIREMENT AT THE MAXIMUM 30 | | | FOOT SPACING. THERE ARE ALSO CONFLICTS WITH PROPOSED | | | AWNING AND STREET TREES. | | | PLANNING STAFF HAS NOT REVIEWED OR APPROVED THE | | | STREETSCAPE PLANS FOR THE AREAS ADJACENT TO THIS | | | PROJECT. PROVIDE THE 100% PLANS FOR REVIEW. | | | 3. NOT SATISFIED. REQUIRED STREET TREES MUST MEET THE | | | 20 FOOT HEIGHT REQUIREMENT AT INSTALLATION. LIST | | | OVERALL HEIGHT ON PLANT LIST. | | | PLANNING STAFF HAS NOT REVIEWED OR APPROVED THE | | | STREETSCAPE PLANS FOR THE AREAS ADJACENT TO THIS | | | PROJECT. PROVIDE THE 100% PLANS FOR REVIEW. | | | | | | 4. NOT SATISFIED. SECTION 94-448 (D)(3) REQUIRES NATIVE | | | TREES IN GOOD CONDITION TO BE PRESERVED ON SITE OR | | | RELOCATED. SUBMIT THE REASON THE TWO EXISTING LIVE OAK | | | TREES CANNOT BE RELOCATED OR USED IN THE PROPOSED | | | STREETSCAPE. | | | PLANNING STAFF HAS NOT REVIEWED OR APPROVED THE | | | STREETSCAPE PLANS FOR THE AREAS ADJACENT TO THIS | | | PROJECT. PROVIDE THE 100% PLANS FOR REVIEW. | | | | | | | | | 5. SATISFIED. PUBLIC AND PRIVATE OPEN SPACE AREAS SHOWN | | | ON SHEET A0.05 MUST BE BROKEN DOWN TO SHOW THE REQUIRED | | | VEGETATED AREA AND ANY TREE CANOPY REQUIREMENT FOR EACH | | | AREA. PASSAGEWAY LESS THAN 7500 SQ FT REQUIRE ZERO ANY | | | OF EITHER. TERRACE REQUIRES 20% MINIMUM VEGETATED AREA. | | | ROOFTOP GARDEN REQUIRES 30% VEGETATED AREA AND 20% TREE | | | CANOPY. TREE CANOPY VALUES CAN BE FOUND IN SECTION | | | 94-109 TABLE IV-8. | | | | | | 6. SATISFIED. AREA LISTED AS POOL DECK ON LEVEL 3 IS | | | NOT AN OPEN SPACE TYPE. CLASSIFY AS A PERMITTED PRIVATE | | | OPEN SPACE TYPE (ROOFTOP GARDEN?) AND SHOW | | | REQUIREMENTS. | | | | | | 7. SATISFIED. ADD COLUMNS FOR NATIVE PLANTS AND DROUGHT | | | TOLERANCE/ WATER USAGE TO THE PLANT LIST SO THAT | | | FLORIDA FRIENDLY POINTS CAN BE SUBSTANTIATED. | | | | | | 8. SATISFIED. TRA IS MISSING FROM THE PLANT LIST. | | | | | | 9. PARTIALLY SATISFIED. SHOW LOCATIONS OF ANY ROOT | | | BARRIERS REQUIRED TO PROTECT UTILITY LINES. | | | BIOBARRIER IS NOT ACCEPTABLE AS ROOT BARRIER, MUST BE | | | HARD PLASTIC ROOT BARRIER DEEP ROOT OR SIMILAR. | | | SOME ROOT BARRIER LOCATIONS SHOWN ARE NOT APPROPRIATE, | | | AS THEY SEPARATE THE ROOTS FROM REQUIRED SOIL AREAS. | | | PROVIDE A ROOT BARRIER DETAIL. | | | | | | 10. NOT SATISFIED. SHOW COMPLIANCE WITH SECTION 94-445 | | | L. PLANT SPECIES. A MINIMUM OF 60 PERCENT OF PLANT | | | MATERIAL ADDED SHALL BE FLORIDA NATIVE OR DROUGHT | | | TOLERANT SPECIES SELECTED FROM THE CITY LIST OR THE | | | LIST OF SPECIES IN THE MOST RECENT EDITION OF SOUTH | | | FLORIDA WATER MANAGEMENT DISTRICT WATERWISE SOUTH | | | FLORIDA LANDSCAPES. | | | PROVIDE THE ACTUAL PERCENTAGE OF DROUGHT TOLERANT AND | | | NATIVE SPECIES ADDED BASED ON THE PROPOSED PLANT LIST. | | | | | | ADDITIONAL COMMENTS 8/16/19: | | | | | | 11. PROVIDE THE 50 POINTS REQUIRED FROM THE FLORIDA | | | FRIENDLY DESIGN OPTIONS FOUND IN SECTION 94-443(G). | | | | | | 12. PER RESOLUTION NO. 304-18 UNDER 2. CITYPLACE CENTER | | | B., FOUR FICUS TREES WITHIN THE PAVED AREAS NEED TO BE | | | SHOWN WITH SUSPENDED PAVEMENT SYSTEM FOR THE ROOT ZONES | | | OF THE TREES. PROVIDE THE LOCATIONS AND DETAIL FOR THE | | | SYSTEM. | | | | | | CONDITIONS OF APPROVAL | | | 1. PRIOR TO THE REMOVAL OR RELOCATION OF ANY TREES ON | | | THE PROPERTY, A TREE ALTERATION PERMIT SHALL BE | | | SUBMITTED, REVIEWED AND APPROVED BY THE DEVELOPMENT | | | SERVICES DEPARTMENT, PLANNING DIVISION. | | | |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
1 |
Status |
F |
Date |
06-10-2019 |
|
|
Cont ID |
|
| Sent By |
rcaranci |
Date |
06-10-2019 |
Time |
14:25 |
Rev Time |
0.00 |
| Received By |
rcaranci |
Date |
06-10-2019 |
Time |
14:25 |
Sent To |
|
|
| Notes |
| 2019-06-10 14:28:37 | FROM: RAY CARANCI, LANDSCAPE PLANNER 561-822-1462 | | | PROJECT: 575 ROSEMARY (MACY?S) Z19050019 | | | JUNE 10, 2019 | | | I HAVE REVIEWED THE ABOVE REFERENCED PETITION, AND | | | PROVIDE THE FOLLOWING COMMENTS: | | | | | | 1. MAKE THE FOLLOWING CORRECTIONS TO THE TREE | | | DISPOSITION PLAN: | | | ? THE WASHINGTONIA PALMS ARE CATEGORY 4, CANOPY VALUE | | | IS 50 SQ FT. | | | ? PROVIDE THE TOTAL SQUARE FOOTAGE OF MITIGATION FOR | | | ALL TREES AND PALMS PROPOSED TO BE REMOVED. | | | ? PROVIDE THE MITIGATION VALUES BY CATEGORY FOR THE | | | PROPOSED STREETSCAPE TREES AND PALMS. | | | | | | 2. THE STREETSCAPE CAN BE IMPROVED TO ACCOMPLISH THE | | | INTENT OF THE CODE SECTION 94-113. THE COCONUT PALMS | | | AND DATE PALMS MAY BE USED, BUT NOT AS COUNTING TOWARD | | | THE TREE REQUIREMENT AT THE MAXIMUM 30 FOOT SPACING. | | | THERE ARE ALSO CONFLICTS WITH PROPOSED AWNING AND | | | STREET TREES. | | | 3. REQUIRED STREET TREES MUST MEET THE 20 FOOT HEIGHT | | | REQUIREMENT AT INSTALLATION. LIST OVERALL HEIGHT ON | | | PLANT LIST. | | | | | | 4. SECTION 94-448 (D)(3) REQUIRES NATIVE TREES IN GOOD | | | CONDITION TO BE PRESERVED ON SITE OR RELOCATED. SUBMIT | | | THE REASON THE TWO EXISTING LIVE OAK TREES CANNOT BE | | | RELOCATED OR USED IN THE PROPOSED STREETSCAPE. | | | | | | 5. PUBLIC AND PRIVATE OPEN SPACE AREAS SHOWN ON SHEET | | | A0.05 MUST BE BROKEN DOWN TO SHOW THE REQUIRED | | | VEGETATED AREA AND ANY TREE CANOPY REQUIREMENT FOR EACH | | | AREA. PASSAGEWAY LESS THAN 7500 SQ FT REQUIRE ZERO ANY | | | OF EITHER. TERRACE REQUIRES 20% MINIMUM VEGETATED AREA. | | | ROOFTOP GARDEN REQUIRES 30% VEGETATED AREA AND 20% TREE | | | CANOPY. TREE CANOPY VALUES CAN BE FOUND IN SECTION | | | 94-109 TABLE IV-8. | | | | | | 6. AREA LISTED AS POOL DECK ON LEVEL 3 IS NOT AN OPEN | | | SPACE TYPE. CLASSIFY AS A PERMITTED PRIVATE OPEN SPACE | | | TYPE (ROOFTOP GARDEN?) AND SHOW REQUIREMENTS. | | | | | | 7. ADD COLUMNS FOR NATIVE PLANTS AND DROUGHT TOLERANCE/ | | | WATER USAGE TO THE PLANT LIST SO THAT FLORIDA FRIENDLY | | | POINTS CAN BE SUBSTANTIATED. | | | | | | 8. TRA IS MISSING FROM THE PLANT LIST. | | | | | | 9. SHOW LOCATIONS OF ANY ROOT BARRIERS REQUIRED TO | | | PROTECT UTILITY LINES. | | | | | | 10. SHOW COMPLIANCE WITH SECTION 94-445 L. PLANT | | | SPECIES. A MINIMUM OF 60 PERCENT OF PLANT MATERIAL | | | ADDED SHALL BE FLORIDA NATIVE OR DROUGHT TOLERANT | | | SPECIES SELECTED FROM THE CITY LIST OR THE LIST OF | | | SPECIES IN THE MOST RECENT EDITION OF SOUTH FLORIDA | | | WATER MANAGEMENT DISTRICT WATERWISE SOUTH FLORIDA | | | LANDSCAPES. | | | PROVIDE THE ACTUAL PERCENTAGE OF DROUGHT TOLERANT AND | | | NATIVE SPECIES ADDED BASED ON THE PROPOSED PLANT LIST. | | | | | | CONDITIONS OF APPROVAL | | | 1. PRIOR TO THE REMOVAL OR RELOCATION OF ANY TREES ON | | | THE PROPERTY, A TREE ALTERATION PERMIT SHALL BE | | | SUBMITTED, REVIEWED AND APPROVED BY THE DEVELOPMENT | | | SERVICES DEPARTMENT, PLANNING DIVISION. | | | | | | |
|
|
| Review Stop |
PW |
PUBLIC WORKS |
| Rev No |
2 |
Status |
P |
Date |
08-20-2019 |
|
|
Cont ID |
|
| Sent By |
|
Date |
08-20-2019 |
Time |
|
Rev Time |
0.00 |
| Received By |
|
Date |
08-20-2019 |
Time |
|
Sent To |
|
|
| Notes |
| 2019-08-20 08:29:48 | PUBLIC WORKS HAS NO FURTHER COMMENTS. | | | | | | MATT HEJAZI | | | 561-822-2045 |
|
|
| Review Stop |
PW |
PUBLIC WORKS |
| Rev No |
1 |
Status |
F |
Date |
06-04-2019 |
|
|
Cont ID |
|
| Sent By |
|
Date |
06-11-2019 |
Time |
|
Rev Time |
|
| Received By |
|
Date |
06-11-2019 |
Time |
|
Sent To |
|
|
| Notes |
| 2019-06-11 08:35:39 | PLEASE PROVIDE THE FOLLOWINGS: | | | - LOS (LEVEL OF SERVICE ANALYSIS) TO REFLECT THE SOLID | | | WASTE VOLUME PRODUCED ALONG WITH THE SIZE OF THE | | | COMPACTOR THAT WILL BE UTILIZED. | | | - AUTO TURN FOR THE SANITATION SERVICE | | | - CONTINGENCY PLAN, FOR WHEN THE COMPACTOR IS OUT OF | | | SERVICE (I.E. CITY DUMPSTER, ROLL-OFF CONTAINER) | | | - DESIGNATED LOCATION FOR THE BULK ITEM PICK UP | | | | | | | | | MATT HEJAZI | | | DEPT. OF PUBLIC WORKS | | | [email protected] | | | 561-822-2045 |
|
|
| Review Stop |
STORM |
STORMWATER |
| Rev No |
4 |
Status |
P |
Date |
10-30-2019 |
|
|
Cont ID |
|
| Sent By |
tward |
Date |
10-30-2019 |
Time |
15:43 |
Rev Time |
0.00 |
| Received By |
tward |
Date |
10-30-2019 |
Time |
16:14 |
Sent To |
|
|
| Notes |
| 2019-10-30 16:04:13 | THE PROPOSED DRAINAGE DESIGN IN THE OCTOBER 4, 2019 | | | SUBMITTAL PACKAGE SHOWS THE STORMWATER RUNOFF FROM THE | | | SIDEWALK AND ROOF DRAINS DIRECTED TO ONSITE | | | EXFILTRATION TRENCHES WITH NO DIRECT CONNECTION TO THE | | | DRAINAGE SYSTEM IN THE PUBLIC RIGHT-OF-WAY. NO DRAINAGE | | | CALCULATION HAVE BEEN SUBMITTED TO INDICATE THE AMOUNT | | | OF RUNOFF THE EXFILTRATION TRENCHES CAN HANDLE. THE EOR | | | MAY HAVE SAID THE 5-YEAR 24-HOUR STORM COULD BE HANDLED | | | BY THE SYSTEM. | | | | | | UNLESS THE EXFILTRATION TRENCHES ARE PERIODICALLY | | | MAINTAINED, THE STORAGE AND DISPOSAL CAPACITY OF THIS | | | DRAINAGE SYSTEM WILL DIMINISH OVERTIME. IT WILL TAKE | | | LONGER FOR THE STORED WATER TO FLOW OUT OF THE SLOTTED | | | PIPE AND INTO THE GROUND TO GROUNDWATER. EVENTUALLY, | | | THE TRENCHES ALONG THE PERIMETER OF THE SITE FOR | | | CAPTURING THE SIDEWALK STORMWATER RUNOFF WILL NO LONG | | | PERFORM THIS FUNCTION BECAUSE THE SYSTEM WILL BE FULL. | | | THE OPPOSITE WILL LIKELY OCCUR IN THAT ROOF RUNOFF WILL | | | BACKFLOW THROUGH THE PERIMETER TRENCHES AND FLOW ON THE | | | SIDEWALK TO THE GUTTER IN THE R/W. SUFFICIENT HEAD | | | PRESSURE COULD OCCUR IN THE DRAINAGE SYSTEM FROM THE | | | ROOF DRAINS TO FORCE OPEN THE MANHOLES LIDS AND | | | MINI-FOUNTAINS ERUPT WITH WATER SPILLING OUT ONTO THE | | | SIDEWALK. BY THIS TIME THE EXFILTRATION TRENCHES WILL | | | NEED TO BE DUG UP AND REPLACED WITH CLEAN STONE/ROCKS. | | | | | | DUE TO THE DEVELOPER'S AGREEMENT FOR CAPTURING THE | | | STORMWATER RUNOFF, THE CITY COULD ADD AS A CONDITION OF | | | APPROVAL THAT THE ONSITE DRAINAGE SYSTEM BE INSPECTED | | | AND CERTIFIED ANNUALLY BY A FL P.E. THAT THE DRAINAGE | | | SYSTEM IS PERFORMING AS ORIGINALLY DESIGNED. | | | | | | TRACY WARD, P.E. | | | SENIOR STORMWATER ENGINEER | | | ENGINEERING SERVICES DEPARTMENT | | | [email protected] | | | 561-494-1120 | | | |
|
|
| Review Stop |
STORM |
STORMWATER |
| Rev No |
3 |
Status |
F |
Date |
09-11-2019 |
|
|
Cont ID |
|
| Sent By |
tward |
Date |
09-11-2019 |
Time |
17:14 |
Rev Time |
0.00 |
| Received By |
tward |
Date |
09-11-2019 |
Time |
17:40 |
Sent To |
|
|
| Notes |
| 2019-09-11 17:35:26 | THE FOLLOWING COMMENTS ARE FROM THE REVIEW OF THE | | | SEPTEMBER 9, 2019 SUBMITTAL REVIEW PACKAGE: | | | | | | 1. SHEET C0.02 - SURVEY DATA NOTE 1 STATES ELEVATIONS | | | ON THE PLANS ARE BASED ON NGVD1929. A NOTE IN THE | | | BOTTOM RIGHT OF THE SHEET STATES ALL ELEVATIONS SHOWN | | | ON THE PLANS ARE BASED ON NAVD1988. | | | | | | 2. SHEET C8.00 - SHOW R/W LINE ON SECTION H-H | | | | | | 3. SHEET C8.01: | | | A. SHOW R/W LINE ON THE SECTIONS. | | | B. SECTION I-I - SLOT DRAIN NOT SHOWN. | | | C. SECTION L-L - WHAT IS THE 8 FOOT AREA NEXT TO THE | | | SIDEWALK? NOTE THE PLAN VIEW DOES NOT SHOW THE SLOT | | | DRAIN IN THE 8 FOOT AREA. | | | | | | 4. PROVIDE DETAIL OF THE SLOT DRAIN. | | | | | | 5. INDICATE HOW ONSITE EXFILTRATION TRENCH DRAINS WILL | | | BE DESIGNED/SIZED. | | | | | | 6. PROVIDE A COPY OF THE STREETSCAPE PLANS (PERMIT NO. | | | 19031272) FOR THE PROPOSED PLANTING ALONG S. ROSEMARY | | | AVE. AND HIBISCUS STREET. | | | | | | TRACY WARD, P.E. | | | SENIOR STORMWATER ENGINEER | | | ENGINEERING SERVICES DEPARTMENT | | | [email protected] | | | 561-494-1120 | | | |
|
|
| Review Stop |
STORM |
STORMWATER |
| Rev No |
2 |
Status |
F |
Date |
08-19-2019 |
|
|
Cont ID |
|
| Sent By |
tward |
Date |
08-19-2019 |
Time |
10:51 |
Rev Time |
0.00 |
| Received By |
tward |
Date |
08-19-2019 |
Time |
11:04 |
Sent To |
|
|
| Notes |
| 2019-08-19 11:04:25 | THE FOLLOWING COMMENTS ARE FROM THE REVIEW OF THE JULY | | | 30, 2019 SUBMITTAL PACKAGE. | | | | | | 1. IT APPEARS ONLY ROOF DRAINS AND CONDENSATE LINES ARE | | | CONNECTED TO THE EXFILTRATION SYSTEMS. SINCE ALL ROOF | | | DRAINAGE IS TO BE CAPTURED AND RETAINED ONSITE, WEIRS | | | AND OUTFALL PIPES WILL NOT BE NECESSARY TO CONNECT TO | | | THE OFFSITE DRAINAGE SYSTEMS. [REPEAT COMMENT] | | | | | | 2. GRADING INFORMATION PROVIDED FOR THE DROPOFF AREA ON | | | WEST STREET APPEARS TO SHOW A LOW SPOT ELEVATION OF | | | 20.13. IS THIS AREA DESIGNED TO HOLD WATER INSTEAD OF | | | DRAINAGE TO AN INLET? | | | | | | 3. PREVIOUS COMMENT REGARDING TREES PROPOSED OVER THE | | | EXISTING DRAINAGE SYSTEM ON S. ROSEMARY AVE. WAS | | | APPARENTLY ADDRESSED BY CROSS HATCHING THE AREA ON THE | | | LANDSCAPE PLANS AND INDICATING THE AREA WAS APPROVED BY | | | CITY COUNCIL (SIC) AS PART OF FACE OF THE CITY | | | RESOLUTION. | | | | | | 4. ON SHEET LH-03 ARE TWO SAND SET PAVER DETAILS. | | | PLEASE INDICATE ON SHEET LH-01 WHERE EACH DETAIL | | | APPLIES. | | | | | | 5. INDICATE ON THE PGD PLAN HOW STORMWATER RUNOFF FROM | | | THE PERIMETER SIDEWALK AREAS WILL BE CAPTURED ONSITE. | | | | | | TRACY WARD, PE | | | SENIOR STORMWATER ENGINEER | | | ENGINEERING SERVICES DEPARTMENT | | | 561-494-1120 | | | [email protected] | | | |
|
|
| Review Stop |
STORM |
STORMWATER |
| Rev No |
1 |
Status |
F |
Date |
06-10-2019 |
|
|
Cont ID |
|
| Sent By |
tward |
Date |
06-10-2019 |
Time |
18:25 |
Rev Time |
0.00 |
| Received By |
tward |
Date |
06-10-2019 |
Time |
18:27 |
Sent To |
|
|
| Notes |
| 2019-06-10 18:27:23 | THIS IS A CONCEPTUAL LEVEL REVIEW. CONSTRUCTION LEVEL | | | DETAILS, DESIGN CALCULATIONS AND THE POLLUTION | | | PREVENTION PLAN WILL BE REVIEWED AS PART OF THE | | | ENGINEERING DEVELOPMENT APPROVAL AND BUILDING PERMIT | | | APPLICATION PROCESSES. THE ENGINEERING DEVELOPMENT | | | APPROVAL APPLICATION FORMS CAN BE DOWNLOADED AT | | | HTTP://WPB.ORG/DEPARTMENTS/ENGINEERING-PUBLIC-WORKS/FOR | | | MS,-PERMITS-APPLICATIONS | | | | | | THE FOLLOWING COMMENTS MUST BE ADDRESSED PRIOR TO SITE | | | PLAN APPROVAL: | | | | | | 1. CONFIRM EXISTING STORM PIPE WEST STREET (ALLEY) IS | | | 15? RCP. THE DRAINAGE AS-BUILTS FOR CITY PLACE PHASE I | | | SHOWS 30? RCP. | | | | | | 2. IT APPEARS ONLY ROOF DRAINS AND CONDENSATE LINES ARE | | | CONNECTED TO THE EXFILTRATION SYSTEMS. SINCE ALL ROOF | | | DRAINAGE IS TO BE CAPTURED AND RETAINED ONSITE, WEIRS | | | AND OUTFALL PIPES WILL NOT BE NECESSARY TO CONNECT TO | | | THE OFFSITE DRAINAGE SYSTEMS. | | | | | | 3. INDICATE HOW THE ROOF DRAINAGE CONVEYED BY ROOF | | | LEADERS AT THE NORTHEAST AND SOUTHEAST CORNERS OF THE | | | BUILDING WILL BE RETAINED ONSITE. | | | | | | 4. HOW WILL DRAINAGE AT THE LOADING DOCK BE HANDLED? | | | | | | 5. INSUFFICIENT GRADING INFORMATION PROVIDED FOR THE | | | DROPOFF AREA ON WEST STREET. PROVIDE GRADES AND A CROSS | | | SECTION FOR THIS AREA. | | | | | | 6. TREES PROPOSED OVER THE EXISTING DRAINAGE SYSTEM ON | | | S. ROSEMARY AVE. | | | | | | | | | THE FOLLOWING COMMENTS MUST BE ADDRESSED PRIOR TO | | | ISSUANCE OF CONSTRUCTION AUTHORIZATION INCLUDING | | | BUILDING PERMITS AND ENGINEERING DEVELOPMENT APPROVAL. | | | | | | 1. AN ENGINEERING DEVELOPMENT APPROVAL APPLICATION MAY | | | BE REQUIRED FROM THE ENGINEERING SERVICES DEPARTMENT. | | | THE ENGINEERING DEVELOPMENT APPROVAL APPLICATION FORMS | | | CAN BE DOWNLOADED AT: HTTP://WPB.ORG/DEPARTMENTS/ENGINE | | | ERING-PUBLIC-WORKS/FORMS,-PERMITS-APPLICATIONS | | | | | | 2. EROSION CONTROL PLAN AND DETAILS TO BE SUBMITTED | | | WITH THE ENGINEERING PERMIT APPLICATION. | | | | | | 3. PROVIDE A COPY OF THE SFWMD ERP MODIFICATION PRIOR | | | TO STARTING CONSTRUCTION. | | | | | | TRACY WARD, PE | | | SENIOR STORMWATER ENGINEER | | | ENGINEERING SERVICES DEPARTMENT | | | 561-494-1120 | | | [email protected] | | | |
|
|
| Review Stop |
SURVEY |
SURVEYING |
| Rev No |
2 |
Status |
P |
Date |
08-19-2019 |
|
|
Cont ID |
|
| Sent By |
vnoel |
Date |
08-19-2019 |
Time |
09:13 |
Rev Time |
0.00 |
| Received By |
vnoel |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2019-08-19 09:16:55 | PASSED WITH CONDITIONS: | | | | | | 1. REVIEW OF MAINTENANCE AGREEMENT CONCERNING LIABILITY | | | OF UTILITIES IN SIDEWALKS. | | | 2. APPROVAL BY MARK HURLEY, CUSTOMER SERVICE. |
|
|
| Review Stop |
SURVEY |
SURVEYING |
| Rev No |
1 |
Status |
F |
Date |
06-10-2019 |
|
|
Cont ID |
|
| Sent By |
vnoel |
Date |
06-10-2019 |
Time |
12:58 |
Rev Time |
|
| Received By |
vnoel |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2019-06-10 13:37:06 | 1. MARK HURLEY WITH CUSTOMER SERVICE (METER SHOP) WILL | | | NEED TO REVIEW THE PROPOSED VERTICAL STACKS AND METER | | | LOCATIONS. | | | 2. NEED TO REVIEW THE 6 NEW STORM MANHOLES TO BE WITHIN | | | THE SIDEWALK AREA. MAY NEED TO RE-VISIT ANY MAINTENANCE | | | AGREEMENTS. | | | 3. SHOULD DOORWAYS BE OPENING INTO SIDEWALK EASEMENTS? | | | 4. SURVEY IS APPROVED AS SUBMITTED. | | | 5. OUTDOOR SEATING WITHIN SIDEWALK EASEMENTS MAY | | | REQUIRE SIDEWALK CAFE' PERMIT. |
|
|
| Review Stop |
TRAFFIC |
TRAFFIC ENGINEERING |
| Rev No |
4 |
Status |
P |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
10-15-2019 |
Time |
|
Rev Time |
0.00 |
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2019-10-15 16:11:33 | PASSED WITH THE FOLLOWING CONDITIONS: | | | CONDITIONS: | | | 1. THE DEVELOPER SHALL CONDUCT AN EVALUATION AT THE | | | INTERSECTION AT THE SOUTHWEST CORNER OF THE SITE FOR | | | REMOVAL OF THE EXISTING ALL-WAY STOP AND SHALL CONVERT | | | TO TWO-WAY STOP IF AN ALL-WAY STOP IS NOT WARRANTED, | | | ONE YEAR AFTER THE FOLLOWING CONDITIONS ARE MET: | | | A. CO IS ISSUED FOR AT LEAST 50% OF THE PROPOSED | | | APARTMENT, OFFICE USE, OR RETAIL USES. | | | B. CO IS ISSUED FOR AT LEAST 85% OF THE PROPOSED | | | APARTMENT, OFFICE USE, OR RETAIL USES. | | | C. THE LAST CO IS ISSUED FOR THE PROPOSED DEVELOPMENT. | | | 2. THE EVALUATION SHALL INCLUDE ANALYSES OF TRAFFIC | | | VOLUMES, SAFETY DATA AND SIGHT DISTANCES AND SHALL BE | | | COMPLETED BY A LICENSED ENGINEER. THE NECESSARY TRAFFIC | | | AND SAFETY DATA SHALL BE COLLECTED BY THE DEVELOPER FOR | | | THE ANALYSES. | | | 3. PROVIDE SURETY FOR THE TRAFFIC EVALUATION AND | | | REMOVAL OF THE ALL-WAY STOP UNTIL THE OBLIGATIONS | | | RELATED TO THE TWO-WAY STOP CONVERSION ANALYSES OR | | | CONSTRUCTION (#1 AND #2 ABOVE) ARE FULLY MET. | | | | | | | | | SHING TSOI | | | CITY IN-HOUSE TRAFFIC CONSULTANT | | | 561-494-1141 | | | [email protected] | | | (IN-HOUSE ON TUESDAYS AND WEDNESDAYS) |
|
|
| Review Stop |
TRAFFIC |
TRAFFIC ENGINEERING |
| Rev No |
3 |
Status |
F |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
09-18-2019 |
Time |
|
Rev Time |
0.00 |
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2019-09-18 09:27:58 | TRAFFIC STUDY COMMENTS: | | | 1. THE CALCULATION FOR THE TRIP GENERATION WAS | | | SUBSTANTIALLY DIFFERENT THAN IN THE PREVIOUS SUBMITTAL, | | | AND SOME OF THE PREVIOUSLY CORRECT CALCULATIONS WERE | | | INCORRECT IN THE LATEST SUBMITTAL. FOR EXAMPLE, THE | | | PASS-BY TRIP PERCENTAGE FOR THE EXISTING MACY'S RETAIL | | | WAS PREVIOUSLY CORRECT AT 39%, BUT AN INCORRECT | | | PERCENTAGE OF 10% WAS USED IN THE LATEST SUBMITTAL; THE | | | MULTIMODAL TRIPS AND PASS-BY TRIPS SHOULD BE APPLIED TO | | | THE ADJUSTED TRIPS CALCULATED IMMEDIATELY PRIOR THESE | | | TRIP REDUCTIONS. PLEASE REVIEW AND REVISE. | | | 2. (PREVIOUS COMMENT) IN THE SYNCHRO ANALYSIS AT | | | OKEECHOBEE BOULEVARD/TAMARIND AVENUE, ADD WBU VOLUMES | | | ONTO WBL VOLUMES AND REMOVE WBU SINCE U-TURN CAUSES | | | ISSUES WITH HCM 2000 ANALYSIS IN SYNCHRO, WHICH RESULT | | | IN UNREALISTIC DELAYS. APPROPRIATE SIGNAL TIMING SHOULD | | | BE USED. ALSO, PLEASE ASSUME 2 NORTHBOUND LANES WHICH | | | IS A COMMITTED OFF-SITE IMPROVEMENT FROM THE KRAVIS | | | CENTER DEVELOPMENT IN THE FUTURE YEAR ANALYSES. | | | SITE PLAN COMMENTS: | | | 1. PLEASE CONSIDER HAVING THE RESIDENTIAL VALET PICK-UP | | | ON THE OPPOSITE SIDE OF HIBISCUS STREET TO REDUCE | | | ADDITIONAL TRAFFIC ON ROSEMARY. | | | 2. PLEASE CONSIDER HAVING THE OFFICE VALET DROP-OFF | | | VEHICLES TO TURN AROUND IN THE ALLEY TO REDUCE | | | ADDITIONAL TRAFFIC ON ROSEMARY. | | | CONDITIONS: | | | 1. PRIOR TO ISSUANCE OF THE FIRST CERTIFICATE OF | | | OCCUPANCY, EVALUATE AND REMOVE ALL-WAY STOP AND CONVERT | | | TO TWO-WAY STOP AT THE SOUTHWEST CORNER OF THE SITE IF | | | ALL-WAY STOP IS NOT WARRANTED. | | | | | | SHING TSOI | | | CITY IN-HOUSE TRAFFIC CONSULTANT | | | 561-494-1141 | | | [email protected] | | | (IN-HOUSE ON TUESDAYS AND WEDNESDAYS) |
|
|
| Review Stop |
TRAFFIC |
TRAFFIC ENGINEERING |
| Rev No |
2 |
Status |
F |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
08-14-2019 |
Time |
|
Rev Time |
0.00 |
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2019-08-14 15:19:01 | TRAFFIC STUDY COMMENTS: | | | 1. THE TRAFFIC STUDY SHOULD BE THOROUGHLY CHECKED BY | | | THE PE TO MAKE SURE THE TRAFFIC ANALYSIS IS COMPLETED | | | CORRECTLY AND PROPERLY REFLECTS THE EXPECTED TRAFFIC | | | CONDITIONS. | | | 2. CLARIFY IF THE PROJECT TRIPS INCLUDE CIRCULATION DUE | | | TO VALET VEHICLES, AND HOW MANY (OR PERCENTAGE OF) | | | VALET VEHICLES ARE EXPECTED. IF NOT, PLEASE INCLUDE | | | VALET VEHICLES IN PROJECT TRIP CALCULATIONS. ALL VALET | | | VEHICLES BOUND FOR PICK-UP WOULD NEED TO CIRCULATE | | | AROUND THE BLOCK USING FERN STREET, ROSEMARY AVENUE AND | | | HIBISCUS STREET AND DEPART FROM SAPODILLA | | | AVENUE/HIBISCUS STREET. ALL VALET VEHICLES BOUND FOR | | | DROP-OFF WOULD NEED TO ACCESS THE VALET AREA FROM | | | ROSEMARY AVENUE/HIBISCUS STREET. | | | 3. THE TRIP GENERATION RATE FOR LAND USE CODE 710 | | | OFFICE SHOULD BE BASED ON GROSS FLOOR AREA. THE SITE | | | PLAN SHOWS A GFA OF 56,928 SF BUT 51,250 SF IS USED IN | | | THE TRIP GENERATION ANALYSIS. PLEASE REVISE. | | | 4. THE TRIP GENERATION RATE FOR LAND USE CODE 820 | | | SHOPPING CENTER SHOULD BE BASED ON GROSS LEASABLE AREA. | | | PLEASE VERIFY AND REVISE. | | | 5. TRIP GENERATION CALCULATIONS FOR SOME OF THE LAND | | | USES DO NOT APPEAR TO BE CONSISTENT, E.G. THE APARTMENT | | | LAND USE DURING PM PEAK HOUR. ALSO, THE PASS-BY | | | PERCENTAGE FOR SHOPPING CENTER DEPENDS ON THE INTENSITY | | | AND SHOULD BE VERIFIED IF THE INTENSITY IS CHANGED. | | | 6. IN THE INTERNAL TRIP CALCULATION, PLEASE CLARIFY THE | | | SOURCE OF THE 12% UNCONSTRAINED INTERNAL TRIP CAPTURE | | | RATE BETWEEN EACH INDIVIDUAL USE. ITE TRIP GENERATION | | | HANDBACK 3RD EDITION SUGGESTS DIFFERENT PERCENTAGES. | | | 7. IN THE SYNCHRO ANALYSIS AT OKEECHOBEE | | | BOULEVARD/TAMARIND AVENUE, ADD WBU VOLUMES ONTO WBL | | | VOLUMES AND REMOVE WBU SINCE U-TURN CAUSES ISSUES WITH | | | HCM 2000 ANALYSIS IN SYNCHRO, WHICH RESULT IN | | | UNREALISTIC DELAYS. APPROPRIATE SIGNAL TIMING SHOULD BE | | | USED. ALSO, PLEASE ASSUME 2 NORTHBOUND LANES WHICH IS A | | | COMMITTED OFF-SITE IMPROVEMENT FROM THE KRAVIS CENTER | | | DEVELOPMENT IN THE FUTURE YEAR ANALYSIS. | | | | | | CONDITIONS: | | | 1. PRIOR TO ISSUANCE OF THE FIRST CERTIFICATE OF | | | OCCUPANCY, EVALUATE AND REMOVE ALL-WAY STOP AND CONVERT | | | TO TWO-WAY STOP AT THE SOUTHWEST CORNER OF THE SITE IF | | | ALL-WAY STOP IS NOT WARRANTED. | | | | | | | | | SHING TSOI | | | CITY IN-HOUSE TRAFFIC CONSULTANT | | | 561-494-1141 | | | [email protected] | | | (IN-HOUSE ON TUESDAYS AND WEDNESDAYS) |
|
|
| Review Stop |
TRAFFIC |
TRAFFIC ENGINEERING |
| Rev No |
1 |
Status |
F |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
06-11-2019 |
Time |
|
Rev Time |
|
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2019-06-11 18:00:23 | 1. PROVIDE BENCHES FOR THE TROLLEY STOP ON ROSEMARY | | | AVENUE. | | | 2. CLARIFY IF THERE WILL BE VALET ON THE CURBSIDE ALONG | | | HIBISCUS STREET. IF SO, PROVIDE VALET QUEUING ANALYSIS. | | | 3. MOVE THE DROP OFF AREA ON HIBISCUS STREET TO THE | | | EAST AWAY FROM THE INTERSECTION. | | | 4. EVALUATE AND REMOVE ALL-WAY STOP AND CONVERT TO | | | TWO-WAY STOP AT THE SOUTHWEST CORNER OF THE SITE IF | | | ALL-WAY STOP IS NOT WARRANTED. | | | 5. PROVIDE CURBSIDE MANAGEMENT PLAN INCLUDING CURBSIDE | | | USAGE MONITORING. | | | 6. PROVIDE BICYCLE PARKING ALONG ROSEMARY AVENUE | | | 7. PROVIDE FREIGHT DELIVERY PLAN IDENTIFYING THE | | | DELIVERY ROUTE, HOURS AND THE TYPE OF FREIGHT VEHICLES. | | | VERIFY THE FREIGHT VEHICLES CAN BE ACCOMMODATED ALONG | | | THE ROUTE, AND ANY IMPACT FROM THE FREIGHT VEHICLE TO | | | TRAFFIC. | | | 8. PROVIDE A PARKING UTILIZATION STUDY TO VERIFY | | | SUFFICIENT PARKING SPACES ARE AVAILABLE IN THE GARAGE. | | | 9. CONSIDER PROVIDING THE FOLLOWING TRANSPORTATION | | | DEMAND MANAGEMENT (TDM) STRATEGIES: | | | A. UNBUNDLE PARKING SPACES FROM THE RESIDENTIAL LEASE | | | B. IMPLEMENT PARKING CASH OUT PROGRAM FOR EMPLOYEES | | | | | | TRAFFIC STUDY COMMENTS: | | | 10. REPORT HCM 2010 OR HCM 6TH RESULTS INSTEAD OF | | | SYNCHRO RESULTS. IF HCM 2010 OR HCM 6TH RESULTS ARE NOT | | | AVAILABLE, REPORT HCM 2000 RESULTS. | | | 11. INTERSECTIONS WITH TRAFFIC COUNTS COLLECTED IN 2018 | | | SHOULD INCLUDE THE PROPOSED DEVELOPMENT TRIPS WITH NO | | | CREDIT FROM THE EXISTING USE SINCE THE EXISTING USE | | | CEASED TO OPERATE STARTING FROM MARCH 2017. | | | 12. SOME OF THE TRIP GENERATION RATES ARE NOT | | | CONSISTENT WITH THE LATEST TRIP RATES FROM PALM BEACH | | | COUNTY. PLEASE REVISE. | | | 13. CLARIFY THE INTERNAL TRIP CAPTURE METHODOLOGY, OR | | | USE INTERNAL TRIP CAPTURE CALCULATIONS BASED ON ITE | | | METHODOLOGY. | | | 14. IDENTIFY THE ACCESS POINTS OF THE PARKING GARAGE. | | | 15. CLARIFY IF IT IS REASONABLE TO HAVE MORE THAN 50% | | | OF TRIPS USING FERN STREET TO ACCESS OKEECHOBEE | | | BOULEVARD, WHILE THERE ARE SHORTER ROUTES AVAILABLE. | | | | | | | | | | | | SHING TSOI | | | CITY IN-HOUSE TRAFFIC CONSULTANT | | | 561-494-1141 | | | [email protected] | | | (IN-HOUSE ON TUESDAYS AND WEDNESDAYS) |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
5 |
Status |
P |
Date |
11-11-2019 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
11-11-2019 |
Time |
11:35 |
Rev Time |
0.00 |
| Received By |
eschneid |
Date |
11-11-2019 |
Time |
11:35 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
4 |
Status |
F |
Date |
10-21-2019 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
10-21-2019 |
Time |
15:07 |
Rev Time |
0.00 |
| Received By |
eschneid |
Date |
10-18-2019 |
Time |
13:50 |
Sent To |
|
|
| Notes |
| 2019-10-21 15:08:05 | CASE NO. PB 950 OOOOO - OCTOBER 4, 2019 RESUBMITTAL | | | REVIEW | | | HIBISCUS TOWER | | | 575 SOUTH ROSEMARY AVENUE | | | | | | - CONTACT ERIC SCHNEIDER @ (561) 822-1446 | | | | | | - PLEASE PROVIDE RESPONSES TO REVIEW COMMENTS IN | | | WRITTEN FORMAT. | | | | | | - WHEN RESUBMITTING, PLEASE PROVIDE A MINIMUM OF ELEVEN | | | (11) PAPER COPIES AND AN ELECTRONIC COPY IN .PNG FORMAT | | | OF ALL PLANS. PLEASE NOTE THAT CHANGES ON THE | | | RESUBMITTED PLANS OR THE SUBMITTAL OF INFORMATION/PLANS | | | TO ADDRESS THE COMMENTS MAY RESULT IN ADDITIONAL | | | COMMENTS. | | | | | | - COMMENT #1 MUST BE SHOWN ON THE PLANS SUBMITTED TO | | | THE PLANNING DIVISION BY NOON, FRIDAY, OCTOBER 25, | | | 2019, TO BE ELIGIBLE TO BE SCHEDULED FOR THE NOVEMBER | | | 19, 2019 PLANNING BOARD MEETING. | | | | | | - COMMENT #2 MUST BE ADDRESSED ON THE PLANS PRIOR TO | | | THE SCHEDULING OF THE CITY COMMISSION HEARING. IF THE | | | COMMENT IS ADDRESSED ON THE PLANS SUBMITTED TO THE | | | PLANNING DIVISION BY NOON, FRIDAY, OCTOBER 25, 2019, | | | STAFF WILL PROVIDE THE MAILER FOR THE DECEMBER 16, 2019 | | | CITY COMMISSION MEETING, TO BE MAILED AT THE SAME TIME | | | AS THE PLANNING BOARD MAILER. OTHERWISE, THE PLANS NEED | | | TO BE UPDATED BY 5 P.M., WEDNESDAY, NOVEMBER 7, 2019, | | | TO RECEIVE THE MAILER FOR THE DECEMBER 16, 2019 CITY | | | COMMISSION MEETING. | | | | | | 1) UPDATED COMMENT: THANK YOU FOR INCLUDING THE ADA | | | RAMP TO PROVIDE ACCESS TO THE ROSEMARY AVENUE FACING | | | MAINTENANCE ROOM ON THE GROSS AREA PLANS, BUT THIS ALSO | | | INCREASES THE FAR FOR THE BUILDING AS IT IS A | | | PASSAGEWAY. THE RAMP NEEDS TO BE INCLUDED IN THE FAR | | | CALCULATIONS. STAFF ASSUMED, INCORRECTLY, THAT YOU | | | WOULD MAKE BOTH CHANGES AS PART OF THE RESUBMITTAL. | | | NOTE: THE PLANS ONLY SHOW 320 SQUARE FEET AVAILABLE | | | BEFORE THE 6.0 FAR IS EXCEEDED. ADDITIONALLY, IF AT THE | | | TIME OF BUILDING PERMIT THE BUILDING OR FIRE PLAN | | | REVIEWERS REQUIRE A DESIGNATED ROUTE FROM THE ADA RAMP | | | TO THE MAINTENANCE ROOM ENTRANCE(S), THEN THE SQUARE | | | FOOTAGE OF THE DESIGNATED ROUTE WILL ALSO COUNT TOWARD | | | THE FAR SQUARE FOOTAGE. | | | | | | 2) UPDATED COMMENT: THE STREETSCAPE ELEMENTS AND | | | LANDSCAPE MUST BE ADDED TO THE SITE, LANDSCAPE AND | | | CIVIL PLANS AND THE CROSS HATCHING REMOVED. | | | | | | CONDITION: THE AC UNITS MOUNTED ON RACKS ON THE WEST | | | BUILDING WALL OF 477 SOUTH ROSEMARY MUST BE REMOVED | | | PRIOR TO THE CONSTRUCTION OF THE 575 SOUTH ROSEMARY | | | BUILDING. | | | | | | CONDITION: WAYFINDING SIGNS ARE REQUIRED TO DIRECT | | | PEDESTRIANS FROM THE GARAGE TO THE OFFICE, RESIDENTIAL | | | AND RETAIL ENTRANCES. | | | | | | CONDITION: THE LEVEL III SITE PLAN APPROVAL WILL | | | CONTAIN THE DEVELOPMENT REGULATION THAT NO LEASES CAN | | | INCLUDE DESIGNATED PARKING IN THE D GARAGE AND THAT NO | | | BARRIERS MAY BE INSTALLED IN THE GARAGE TO CREATE | | | SEPARATED PARKING AREAS FOR SPECIFIC TENANTS UNLESS A | | | MINOR AMENDMENT IS APPROVED THAT BOTH DESIGNATES THE | | | LOCATION OF THE RESERVED PARKING SPACES AND THE | | | BARRIERS AS WELL AS VERIFIES THAT THERE IS SUFFICIENT | | | PARKING WITHIN THE ROSEMARY SQUARE CONTROLLED GARAGES | | | TO ACCOMMODATE THE REQUIRED PARKING FOR THE ENTIRE | | | PROJECT. | | | | | | CONDITION: RECORD A PUBLIC ACCESS EASEMENT, IN A FORM | | | ACCEPTABLE TO THE CITY ATTORNEY'S OFFICE, FOR THE | | | PUBLIC SPACE TERMINATING THE PUBLIC OPEN SPACE - | | | PASSAGE. | | | | | | CONDITION: IF VALET SERVICE IS UTILIZED FOR THE | | | RESIDENTIAL TOWER, THEN PRIOR TO THE ISSUANCE OF THE | | | C.O. FOR THE RESIDENTIAL TOWER, A VALET PLAN MUST BE | | | SUBMITTED TO THE CITY AND APPROVED BY THE PLANNING AND | | | TRAFFIC ENGINEERING STAFF. | | | | | | CONDITION: IF VALET SERVICE IS UTILIZED FOR THE OFFICE | | | TOWER, THEN IT MUST EITHER UTILIZE THE SERVICE ALLEY | | | LOADING SPACES FOR VEHICLES TO TURN AROUND, OR AN | | | ALTERNATIVE VALET PLAN MUST BE SUBMITTED TO THE CITY | | | AND APPROVED BY THE PLANNING AND TRAFFIC ENGINEERING | | | STAFF. | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
F |
Date |
09-24-2019 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
09-24-2019 |
Time |
15:51 |
Rev Time |
6.00 |
| Received By |
eschneid |
Date |
09-20-2019 |
Time |
13:46 |
Sent To |
|
|
| Notes |
| 2019-09-24 15:52:02 | CASE NO. PB 950 OOOOO - 2ND RESUBMITTAL REVIEW | | | HIBISCUS TOWER | | | 575 SOUTH ROSEMARY AVENUE | | | | | | - CONTACT ERIC SCHNEIDER @ (561) 822-1446 | | | | | | - PLEASE PROVIDE RESPONSES TO REVIEW COMMENTS IN | | | WRITTEN FORMAT. | | | | | | - WHEN RESUBMITTING, PLEASE PROVIDE A MINIMUM OF ELEVEN | | | (11) PAPER COPIES AND AN ELECTRONIC COPY IN .PNG FORMAT | | | OF ALL PLANS. PLEASE NOTE THAT CHANGES ON THE | | | RESUBMITTED PLANS OR THE SUBMITTAL OF INFORMATION/PLANS | | | TO ADDRESS THE COMMENTS MAY RESULT IN ADDITIONAL | | | COMMENTS. | | | | | | - THE COMMENTS SHALL BE SUFFICIENTLY ADDRESSED AND | | | SUBMITTED TO THE PLANNING DIVISION BY 5 PM ON FRIDAY, | | | SEPTEMBER 27, 2019, TO BE ELIGIBLE TO BE SCHEDULED FOR | | | THE NOVEMBER 19, 2019 PLANNING BOARD MEETING. | | | | | | - PLEASE NOTE THAT IF THESE COMMENTS ARE NOT | | | SUFFICIENTLY ADDRESSED, THE APPLICANT WILL BE ASSESSED | | | A RESUBMITTAL FEE. SUCH FEE IS 20% OF THE ORIGINAL | | | APPLICATION FEE ($600). | | | | | | 1) UPDATED COMMENT: THANK YOU FOR PROVIDING THE | | | DIMENSION LINE SHOWING THE HEIGHT OF PODIUM ALONG | | | HIBISCUS STREET. | | | | | | A. THE PLANS SHOW THE RAILING THAT WAS AT THE EDGE OF | | | THE PODIUM HAS BEEN REMOVED. DOES THIS RESULT IN THE | | | 5TH FLOOR RESIDENTIAL UNITS FACING HIBISCUS STREET NO | | | LONGER HAVING A TERRACE? NO 5TH FLOOR PLAN WAS PROVIDED | | | TO SHOW WHAT OCCURS UNDERNEATH THE BALCONIES. SINCE | | | THIS AREA IS STILL THE TOP OF THE PODIUM, NO RAILING | | | CAN BE PROVIDED TO CREATE TERRACES SINCE THIS WOULD | | | EXCEED THE MAXIMUM PODIUM HEIGHT. IF A TERRACE IS | | | DESIRED ON TOP OF THE PODIUM, THEN STAFF SUGGESTS | | | LOWERING THE FLOOR HEIGHTS BY ENOUGH (BARRIER NEEDS TO | | | BE 42 INCHES ABOVE THE WALKING SURFACE PER ROBERT | | | BROWN, BUILDING OFFICIAL) TO ALLOW ACCESS TO THE | | | TERRACE. | | | B. THE COLUMNS THAT ARE SHOWN SUPPORTING THE UNDERSIDE | | | OF THE BALCONIES EXTEND ABOVE THE 60 FOOT PODIUM | | | MAXIMUM HEIGHT. THESE COLUMNS AT THE PODIUM LEVEL ARE | | | NOT BALCONY ENCROACHMENTS (THE LOWEST LEVEL BALCONY | | | SLAB MAY NOT HAVE COLUMNS UNDERNEATH IT), BUT RATHER | | | PART OF THE TOWER; THEREFORE, THE TOWER DOES NOT MEET | | | THE MINIMUM 50 FOOT TOWER SETBACK. NOTE: THE COLUMNS | | | ARE PERMITTED ABOVE THE FIRST BALCONY SLAB. | | | | | | | | | 2) UPDATED COMMENT: STAFF HAS REVIEWED THE REVISED | | | ACTIVE USE DIAGRAMS FOR THE SOUTH ROSEMARY AVENUE | | | FRONTAGE AND HAS THE FOLLOWING COMMENTS: | | | | | | A. THANK YOU FOR PROVIDING THE REQUIRED WINDOWS FOR THE | | | TWO MAINTENANCE OFFICES. PLEASE LABEL THESE ON THE | | | ELEVATIONS. THE REQUIRED DIRECT VIEW FOR THE RETAIL ON | | | THE 2ND STORY NEEDS TO BE SHOWN WITH THIS SUBMITTAL AND | | | NOT DELAYED UNTIL THE BUILDING PERMIT SO THAT AN | | | ACCURATE REPRESENTATION OF CODE COMPLIANCE CAN BE SHOWN | | | AS PART OF THE PUBLIC HEARING PROCESS. | | | B. THE ADDITION OF THE ADA RAMP TO PROVIDE ACCESS TO | | | THE ROSEMARY AVENUE FACING MAINTENANCE ROOM INCLUDED | | | THE EXPANSION OF THE TENANT STORAGE ROOM BY 50 SQUARE | | | FEET (WALLS MOVED FROM ONE SIDE OF THE COLUMNS TO THE | | | OTHER), YET THE STORAGE ROOM GSF CALCULATION DID NOT | | | INCREASE. THE LEVEL 3 GROSS AREA DIAGRAM NEEDS TO BE | | | UPDATED TO REFLECT THE EXPANDED STORAGE ROOM, THE ADA | | | ACCESS RAMP AND THE REDUCTION OF THE MECHANICAL ROOM, | | | WITH ALL TABLES UPDATED ACCORDINGLY. | | | | | | 3) UPDATED COMMENT: STAFF HAS REVIEWED THE PRIVATE OPEN | | | SPACE AND HAS THE FOLLOWING COMMENTS: | | | | | | A. LEVEL 4 OPEN SPACE AREAS A & B ARE A ROOFTOP | | | GARDENS, SO THEY DOES NOT REQUIRE PUBLIC RIGHT-OF-WAY | | | ABUTMENT. REMOVE THAT LINE ITEM FROM THE TABLE. | | | B. LEVEL 4 OPEN SPACE AREA C DOES NOT COMPLY WITH THE | | | MINIMUM PUBLIC RIGHT-OF-WAY ABUTMENT TO BE CONSIDERED A | | | TERRACE. THE WEST SIDE OF THE BUILDING ABUTS AN ACCESS | | | EASEMENT, NOT A PUBLIC RIGHT-OF-WAY. PRIVATE OPEN SPACE | | | AT THIS LOCATION CAN ONLY BE A ROOFTOP GARDEN. PLEASE | | | UPDATE THE TABLE AND PLANS ACCORDINGLY. | | | C. LEVEL 5 OPEN SPACE AREA A DOES NOT COMPLY WITH THE | | | MINIMUM PUBLIC RIGHT-OF-WAY ABUTMENT TO BE CONSIDERED A | | | TERRACE. THE WEST SIDE OF THE BUILDING ABUTS AN ACCESS | | | EASEMENT, NOT A PUBLIC RIGHT-OF-WAY. PRIVATE OPEN SPACE | | | AT THIS LOCATION CAN ONLY BE A ROOFTOP GARDEN. PLEASE | | | UPDATE THE TABLE AND PLANS ACCORDINGLY. | | | | | | 4) PUBLIC OPEN SPACE - PASSAGE REQUIREMENTS | | | | | | A. UPDATED COMMENT: A PASSAGEWAY IS REQUIRED TO CONNECT | | | TWO OR MORE PUBLIC RIGHTS-OF-WAY OR PUBLIC SPACES. THE | | | ACCESS EASEMENT ON THE WEST SIDE OF THE BUILDING IS NOT | | | A PUBLIC RIGHT-OF-WAY SO THIS SIDE OF THE PASSAGEWAY | | | NEEDS TO TERMINATE AT A PUBLIC SPACE (GENERALLY THE | | | AREA UNDER THE BUILDING ALONG THE ACCESS EASEMENT). IN | | | ORDER FOR THIS AREA TO BE CLASSIFIED AS PUBLIC SPACE, | | | IT WILL NEED A PUBLIC ACCESS EASEMENT RECORDED FOR IT | | | AS WELL AS HAVE SEATING INSTALLED. THE PASSAGEWAY WILL | | | END AT THE COVERED PUBLIC SPACE. --- THE RESPONSE | | | STATES THAT THE APPLICANT AGREES TO A PUBLIC ACCESS | | | EASEMENT. THIS WILL BE INCLUDED AS A REQUIREMENT PRIOR | | | TO THE FINAL INSPECTION FOR THE BUILDING. THE PLANS | | | FAIL TO SHOW SEATING FOR THE PUBLIC SPACE. | | | | | | 5) UPDATED COMMENT: THE ELEMENTS PROJECTING FROM THE | | | ROSEMARY AVENUE AND HIBISCUS STREET FACADES CAN FALL | | | UNDER ONE OF THE FOLLOWING CLASSIFICATIONS: | | | ARCHITECTURAL FEATURE, AWNING, BALCONY AND CANOPY. | | | | | | A. ARCHITECTURAL FEATURE: THIS IS LISTED AS KEYNOTE 15 | | | ON THE ELEVATION KEY AND SHOWN ON THE PLANS AS EYEBROWS | | | NO MORE THAN TWO FEET (SCALED) FROM THE RESIDENTIAL | | | PODIUM BUILDING FACADE. HOWEVER, THERE ARE ADDITIONAL | | | ITEMS, KEYNOTE 3 GLASS AND ALUMINUM AWNINGS, LOCATED ON | | | THE 2ND AND 3RD FLOORS OF THE OFFICE AND RESIDENTIAL | | | PORTIONS OF THE SITE THAT ARE CALLED AWNINGS, BUT DO | | | NOT MEET THE DMP DEFINITION OF AN AWNING. DUE TO THE | | | DESIGN, LOCATION AND SIZE OF THESE ITEMS, THEY CAN ONLY | | | BE CONSIDERED ARCHITECTURAL FEATURES, AND NEED TO BE | | | DESIGNATED AS SUCH ON THE PLANS. | | | B. AWNING: THERE ARE NO AWNINGS DEPICTED ON THE PLANS. | | | C. BALCONY: THE BALCONY ALONG ROSEMARY AVENUE COMPLIES | | | WITH THE PROJECTION STANDARDS. | | | D. CANOPY: THERE ARE THREE PROJECTIONS WHICH ARE | | | CONSIDERED CANOPIES (TWO ON HIBISCUS STREET AND ONE ON | | | ROSEMARY AVENUE) OVER THE FIRST FLOOR ENTRIES TO THE | | | RESIDENTIAL AND RETAIL AREAS. THEY ARE LISTED AS | | | KEYNOTE 3 GLASS AND ALUMINUM AWNINGS. THIS DESIGNATION | | | NEEDS TO CHANGE AS THEY DO NOT MEET THE DEFINITION OF | | | AN AWNING (LOCATED BETWEEN, RATHER THAN ACROSS, | | | SIGNIFICANT VERTICAL ARCHITECTURAL FEATURES THAT MAKE | | | UP THE COMPOSITION OF THE FACADE). SINCE THESE ITEMS | | | ARE CANOPIES, THEY NEED TO BE A MINIMUM OF EIGHT (8) | | | FEET IN DEPTH. THIS DIMENSION LINE NEEDS TO BE SHOWN ON | | | THE ELEVATION PLANS. | | | | | | 6) UPDATED COMMENT: THE TYPICAL BALCONY PLAN DOES NOT | | | MATCH THE ELEVATION PLANS FOR THE NORTHERN SIDE OF THE | | | BUILDING. THE COLUMN WITHIN THE BALCONY AREA (EAST | | | POINT AREA) IS SHOWN TWO FEET CLOSER TO THE BUILDING | | | THAN IT IS ON THE ELEVATION DRAWINGS. THE EAST | | | ELEVATION SHOWS THE BALCONY EXTENDING TWO FEET LESS | | | THAN THE FLOOR PLANS. | | | | | | 7) REPEAT COMMENT: STAFF HAS REVIEWED THE PROPOSED | | | RESIDENTIAL TOWER VALET PLAN AND DOES NOT SUPPORT THE | | | USE OF FERN STREET AND SOUTH ROSEMARY AVENUE TO RETURN | | | THE VEHICLES. THIS PUTS ADDITIONAL VEHICLE TRIPS ON | | | THESE TWO STREETS. AN ALTERNATIVE VALET PICK-UP IS | | | REQUIRED. WHERE IS THE VALET AREA IN THE GARAGE? | | | | | | 8) REPEAT COMMENT: STAFF DOES NOT SUPPORT THE USE OF | | | FERN STREET AND SAPODILLA AVENUE FOR THE VALET AS THIS | | | PUTS ADDITIONAL VEHICLE TRIPS ON THESE ROADWAYS. AN | | | ALTERNATIVE IS TO HAVE THE VALETS USE ONE OF THE | | | SERVICE AREA SPACES AS A TURNAROUND SPACE SO THEY CAN | | | GET THE GARAGE WITHOUT USING THE STREET NETWORK. | | | | | | 9) UPDATED COMMENT: THE PASSAGEWAY BICYCLE RACK DETAIL | | | DOES NOT MEET CODE REQUIREMENTS. THE RACKS SHOWN ON THE | | | INSTALLATION PLANS DO NOT COMPLY WITH ANY OF THE MODELS | | | SHOWN ON THE BIKE RACK REQUIREMENTS DETAIL. NOTE: WHILE | | | STAFF FEELS IT IS ALWAYS BETTER TO PROVIDE EXTRA SPACE | | | FOR PARK BICYCLES, THE 13 FEET IS WIDER THAN IS | | | REQUIRED FOR 6 BICYCLE PARKING SPACES. | | | | | | 10) UPDATED COMMENT: PROVIDE BICYCLE RACKS ALONG | | | ROSEMARY FOR THE RETAIL CUSTOMERS. THE BICYCLE RACKS | | | (AND THE OTHER ROSEMARY AVENUE IMPROVEMENTS) MUST BE | | | SHOWN ON THESE PLANS. NOTE: THE CITY COMMISSION DID NOT | | | APPROVE 100% DRAWINGS AS PART OF THE FACE OF THE CITY | | | RESOLUTION, SO THESE PLANS NEED TO BE SHOWN ON THIS SET | | | OF DRAWINGS. | | | | | | 11) UPDATED COMMENT: THE ROOF AREAS THAT ARE NOT | | | INCLUDED AS OPEN SPACE OR HAVE MECHANICAL EQUIPMENT ARE | | | REQUIRED TO HAVE GREEN ROOF OR SOLAR INSTALLATION. THE | | | DETAILS WILL BE INCLUDED AT TIME OF BUILDING PERMIT; | | | HOWEVER, THE PLANS MUST STATE THAT GREEN ROOF OR SOLAR | | | INSTALLATIONS ARE REQUIRED ON THE ROOVES. NOTE: THE | | | COMMENT RESPONSE SEEMS TO INDICATE THAT DUE THE | | | BUILDING HAVING DIFFERENT ROOF AREAS, ONLY ONE OF THESE | | | AREAS NEEDS TO HAVE GREEN OR SOLAR INSTALLATION TO | | | COMPLY WITH THE DEVELOPMENT REGULATIONS, WHICH IS NOT | | | CORRECT. ALL ROOF AREAS NEED TO HAVE EITHER OPEN SPACE, | | | MECHANICAL OR GREEN/SOLAR. | | | | | | 12) REPEAT COMMENT: THE PHOTOMETRIC PLAN SHOWS LIGHTING | | | LEVELS AT THE CURB IN EXCESS OF THE PERMITTED ONE FOOT | | | CANDLE. ---- RESUBMITTED SHEET E-0.1 STILL SHOWS LIGHT | | | LEVELS AT THE CURB EXCEEDING ONE FOOTCANDLE. | | | | | | CONDITION: THE AC UNITS MOUNTED ON RACKS ON THE WEST | | | BUILDING WALL OF 477 SOUTH ROSEMARY MUST BE REMOVED | | | PRIOR TO THE CONSTRUCTION OF THE 575 SOUTH ROSEMARY | | | BUILDING. | | | | | | CONDITION: WAYFINDING SIGNS ARE REQUIRED TO DIRECT | | | PEDESTRIANS FROM THE GARAGE TO THE OFFICE, RESIDENTIAL | | | AND RETAIL ENTRANCES. | | | | | | CONDITION: THE LEVEL III SITE PLAN APPROVAL WILL | | | CONTAIN THE DEVELOPMENT REGULATION THAT NO LEASES CAN | | | INCLUDE DESIGNATED PARKING IN THE D GARAGE AND THAT NO | | | BARRIERS MAY BE INSTALLED IN THE GARAGE TO CREATE | | | SEPARATED PARKING AREAS FOR SPECIFIC TENANTS UNLESS A | | | MINOR AMENDMENT IS APPROVED THAT BOTH DESIGNATES THE | | | LOCATION OF THE RESERVED PARKING SPACES AND THE | | | BARRIERS AS WELL AS VERIFIES THAT THERE IS SUFFICIENT | | | PARKING WITHIN THE ROSEMARY SQUARE CONTROLLED GARAGES | | | TO ACCOMMODATE THE REQUIRED PARKING FOR THE ENTIRE | | | PROJECT. | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
08-26-2019 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
08-26-2019 |
Time |
17:51 |
Rev Time |
12.00 |
| Received By |
eschneid |
Date |
08-22-2019 |
Time |
09:47 |
Sent To |
|
|
| Notes |
| 2019-08-26 17:51:48 | CASE NO. PB 950 OOOOO - 1ST RESUBMITTAL REVIEW | | | HIBISCUS TOWER | | | 575 SOUTH ROSEMARY AVENUE | | | | | | - CONTACT ERIC SCHNEIDER @ (561) 822-1446 | | | | | | - PLEASE PROVIDE RESPONSES TO REVIEW COMMENTS IN | | | WRITTEN FORMAT. | | | | | | - WHEN RESUBMITTING, PLEASE PROVIDE A MINIMUM OF ELEVEN | | | (11) PAPER COPIES AND AN ELECTRONIC COPY IN .PNG FORMAT | | | OF ALL PLANS. PLEASE NOTE THAT CHANGES ON THE | | | RESUBMITTED PLANS OR THE SUBMITTAL OF INFORMATION/PLANS | | | TO ADDRESS THE COMMENTS MAY RESULT IN ADDITIONAL | | | COMMENTS. | | | | | | - THE COMMENTS SHALL BE SUFFICIENTLY ADDRESSED AND | | | SUBMITTED TO THE PLANNING DIVISION BY 5 PM ON FRIDAY, | | | AUGUST 30, 2019, TO BE ELIGIBLE TO BE SCHEDULED FOR THE | | | OCTOBER 15, 2019 PLANNING BOARD MEETING. | | | | | | - PLEASE NOTE THAT SINCE PREVIOUSLY-ISSUED COMMENTS | | | WERE NOT BE SUFFICIENTLY ADDRESSED, THE APPLICANT WILL | | | BE ASSESSED A RESUBMITTAL FEE. SUCH FEE IS 20% OF THE | | | ORIGINAL APPLICATION FEE ($600). | | | | | | - PUBLIC HEARING NOTIFICATION SIGNAGE SHALL BE POSTED | | | IN ACCORDANCE WITH THE REQUIREMENTS OF SECTION | | | 94-39(I)(5) OF THE ZONING AND LAND DEVELOPMENT | | | REGULATIONS. | | | | | | 1) THE SCALE BAR ON SHEET A0.04.2 PRINTED MULTIPLE | | | SCALES AND IS UNREADABLE. THIS OCCURS ON A FEW SHEETS, | | | SO PLEASE CORRECT. | | | | | | 2) REPEAT COMMENT: PROVIDE THE DIMENSION LINE SHOWING | | | THE FULL HEIGHT OF THE PODIUM, PLUS THE HIGHEST POINT | | | OF THE HEIGHT ENCROACHMENT ON THE ELEVATION PLANS. THE | | | PODIUM HEIGHT DIMENSION WAS NOT PROVIDED FOR THE | | | HIBISCUS STREET FRONTAGE. THE WESTERN PORTION OF THE | | | PODIUM ALONG HIBISCUS STREET (PRIMARILY THE PRIVATE | | | TERRACE) SCALES TO EXCEED 60 FEET AND ADDITIONALLY HAS | | | A VERTICAL ENCROACHMENT (RAILING) EXCEEDING THE 60 FOOT | | | ALLOWANCE. | | | | | | 3) UPDATED COMMENT: THANK YOU FOR PROVIDING ADDITIONAL | | | INFORMATION REGARDING THE FACADE ARTICULATION. BASED ON | | | THE RESUBMITTED INFORMATION, STAFF HAS IDENTIFIED THE | | | FOLLOWING ITEMS WHICH STILL MUST BE PROVIDED: | | | | | | A. THE AMOUNT OF GROUND FLOOR TRANSPARENCY PROVIDED | | | ALONG SOUTH ROSEMARY AVENUE AND HIBISCUS STREET IS NOT | | | LISTED ON THE PLANS. THE ONLY CALCULATION LISTED IS HOW | | | MUCH IS REQUIRED. | | | B. THE AMOUNT OF FENESTRATION FOR THE PODIUM AND THE | | | TOWER IS NOT LISTED ON THE PLANS. ONLY A STATEMENT THAT | | | THE FENESTRATION EXCEEDS 15% IS LISTED ON THE PLANS. | | | C. THE TAG LINES FOR THE WEST ELEVATIONS FOR MATERIAL | | | 01 AND 02 SEEM TO POINT TO THE WRONG MATERIAL. | | | D. PLEASE CONSIDER ADDITIONAL WINDOWS OVERLOOKING THE | | | OUTDOOR SEATING AREA FROM THE GROUND LEVEL RETAIL AND | | | UPPER LEVEL OFFICE. | | | | | | 4) UPDATED COMMENT: PLANAR BREAKS ARE REQUIRED FOR ALL | | | LEVELS OF THE PODIUM. THE PLANS DO NOT CLEARLY SHOW | | | EVIDENCE THAT THIS OCCURS. | | | | | | A. THE SOUTH ROSEMARY AVENUE FRONTAGE (GROUND FLOOR) | | | ADDED DOORWAYS THAT ARE BEING COUNTED TOWARD MEETING | | | THE MINIMUM LINEAR FEET OF PLANAR BREAK. IN ORDER FOR | | | DOORWAYS TO COUNT TOWARD MEETING THIS REQUIREMENT, THE | | | DOORWAY RECESS (THE PLANER BREAK) NEEDS TO CONTINUE | | | FROM GRADE FOR THE FULL HEIGHT OF THE GROUND FLOOR. THE | | | DRAWINGS DO NOT CLEARLY INDICATE THAT THE DOORWAYS | | | EXTEND THE FULL HEIGHT OF THE GROUND FLOOR, AND IN FACT | | | IT APPEARS THAT THE DOORWAYS ARE NOT THE FULL HEIGHT OF | | | THE GROUND FLOOR. | | | B. ON THE SOUTH ROSEMARY AVENUE FRONTAGE (2ND AND 3RD | | | FLOOR), WHILE THE OUTDOOR SEATING RECESS AND THE OFFICE | | | TERRACE COMBINE TO MEET THE MINIMUM REQUIRED PLANAR | | | BREAK AND THE RETAIL ONE CONTINUES TO EXCEED THIS | | | REQUIREMENT, PLEASE CHECK THE SECTION DRAWING ON SHEET | | | A3.01 AS IS APPEARS THAT THE PROPOSED PLANAR BREAK IS | | | NOT DEPICTED ACCURATELY. | | | C. THE HIBISCUS STREET FRONTAGE (2ND FLOOR) ADDED A | | | RECESS THAT IS BEING COUNTED TOWARD MEETING THE MINIMUM | | | LINEAR FEET OF PLANAR BREAK. IN ORDER FOR RECESS TO | | | COUNT TOWARD MEETING THIS REQUIREMENT, THE IT (THE | | | PLANER BREAK) NEEDS TO CONTINUE THE FULL HEIGHT OF THE | | | 2ND FLOOR. THE DRAWINGS DO NOT CLEARLY INDICATE THAT | | | THE RECESS EXTENDS THE FULL HEIGHT OF THE 2ND FLOOR. | | | | | | 5) UPDATED COMMENT: STAFF HAS REVIEWED THE REVISED | | | ACTIVE USE DIAGRAMS FOR THE SOUTH ROSEMARY AVENUE | | | FRONTAGE AND HAS THE FOLLOWING COMMENTS: | | | | | | A. THE MAINTENANCE OFFICE ADDED TO THE 3RD FLOOR DOES | | | NOT APPEAR TO HAVE ADA ACCESSIBILITY. PLEASE DESCRIBE | | | HOW THIS SPACE WILL MEET BUILDING CODE REQUIREMENTS. IF | | | THIS ROOM CANNOT BE CONSTRUCTED AS SHOWN ON THE PLANS, | | | THEN IT WILL CAUSE ISSUES DURING THE PERMITTING | | | PROCESS. | | | B. THE ZONING AND LAND DEVELOPMENT REGULATIONS REQUIRE | | | THAT ACTIVE USES HAVE A DIRECT VIEW TO THE ADJACENT | | | STREETS OR PUBLIC OPEN SPACE. THIS DOES NOT OCCUR FOR | | | THE 2ND STORY RETAIL ALONG SOUTH ROSEMARY AVENUE OR | | | HIBISCUS STREETS SINCE THE PROPOSED FLUTED CHANNEL | | | GLASS IS NOT TRANSPARENT. ADDITIONALLY, THE TWO | | | MAINTENANCE OFFICES (BOTH COUNTED AS ACTIVE USE) HAVE | | | NO DIRECT VIEW TO THE ADJACENT STREETS | | | | | | 6) UPDATED COMMENT: STAFF HAS REVIEWED THE PUBLIC OPEN | | | SPACE COMPLIANCE TABLE FOR THE OUTDOOR SEATING AREA | | | ALONG SOUTH ROSEMARY AVENUE AND NOTED THAT IT | | | INCORRECTLY INCLUDES THE SQUARE FOOTAGE FOR THE AREA | | | UNDER THE 2ND AND 3RD FLOORS OF THE BUILDING. THIS AREA | | | DOES NOT MEET THE DEFINITION OF OVERHEAD COVER, WHICH | | | INCLUDES AWNINGS, CANOPIES, COLONNADES, PERGOLAS, | | | TRELLISES OR OTHER SIMILAR STRUCTURES. THE STAFF | | | CALCULATES THE ACTUAL OPEN SPACE AREA AS APPROXIMATELY | | | 937 SF AND IT APPEARS THAT THE OPEN SPACE MINIMUMS HAVE | | | BEEN MET AS SHOWN. UPDATE THE TABLE WITH THE ACCURATE | | | OPEN SPACE AREA AND CORRESPONDING COMPLIANCE | | | VERIFICATION. NOTE: THE LANDSCAPE UNDER THE BUILDING | | | MAY NOT BE INCLUDED IN THE PROVIDED LANDSCAPE | | | CALCULATION. | | | | | | 7) UPDATED COMMENT: STAFF HAS REVIEWED THE PRIVATE OPEN | | | SPACE AND HAS THE FOLLOWING COMMENTS: | | | | | | A. LEVEL 4 OPEN SPACE AREA B DOES NOT COMPLY WITH THE | | | MINIMUM PUBLIC RIGHT-OF-WAY ABUTMENT TO BE CONSIDERED A | | | TERRACE. THIS PRIVATE OPEN SPACE IS MORE THAN 60 FEET | | | FROM THE SOUTH ROSEMARY AVENUE PUBLIC RIGHT-OF-WAY AND | | | THE SEPARATION INCLUDES MECHANICAL ROOMS AND THE | | | CHILLER ENCLOSURES. PRIVATE OPEN SPACE AT THIS LOCATION | | | CAN ONLY BE A ROOFTOP GARDEN. PLEASE UPDATE THE TABLE | | | AND PLANS ACCORDINGLY. | | | B. LEVEL 4 OPEN SPACE AREA C DOES NOT COMPLY WITH THE | | | MINIMUM PUBLIC RIGHT-OF-WAY ABUTMENT TO BE CONSIDERED A | | | TERRACE. THE WEST SIDE OF THE BUILDING ABUTS AN ACCESS | | | EASEMENT, NOT A PUBLIC RIGHT-OF-WAY. PRIVATE OPEN SPACE | | | AT THIS LOCATION CAN ONLY BE A ROOFTOP GARDEN. PLEASE | | | UPDATE THE TABLE AND PLANS ACCORDINGLY. | | | C. LEVEL 5 OPEN SPACE INCORRECTLY CALCULATES THE AMOUNT | | | OF PUBLIC RIGHT-OF-WAY ABUTMENT. ONLY THE 96 FOOT 9 | | | INCH SECTION OF THE TERRACE MAY COUNT (AS PREVIOUSLY | | | STATED THE ACCESS EASEMENT DOES NOT MEET THE PUBLIC | | | RIGHT-OF-WAY REQUIREMENT). WHILE THE MINIMUM 20% HAS | | | BEEN MET, THE TABLE NEEDS TO BE UPDATED ACCORDINGLY. | | | NOTE: THE SQUARE FOOTAGE ASSOCIATED WITH THIS PRIVATE | | | OPEN SPACE MAY BE AFFECTED BY CORRECTING THE RAILING | | | HEIGHT FROM COMMENT #2. | | | | | | 8) UPDATED COMMENT: PLEASE DESCRIBE HOW THE LEVEL 4 | | | ROOFTOP GARDEN WILL BE USED (ACCESSED) BY THE RESIDENTS | | | OR THE OFFICE TENANTS. | | | | | | 9) PUBLIC OPEN SPACE - PASSAGE REQUIREMENTS | | | | | | A. UPDATED COMMENT: A PASSAGEWAY IS REQUIRED TO CONNECT | | | TWO OR MORE PUBLIC RIGHTS-OF-WAY OR PUBLIC SPACES. THE | | | ACCESS EASEMENT ON THE WEST SIDE OF THE BUILDING IS NOT | | | A PUBLIC RIGHT-OF-WAY SO THIS SIDE OF THE PASSAGEWAY | | | NEEDS TO TERMINATE AT A PUBLIC SPACE (GENERALLY THE | | | AREA UNDER THE BUILDING ALONG THE ACCESS EASEMENT). IN | | | ORDER FOR THIS AREA TO BE CLASSIFIED AS PUBLIC SPACE, | | | IT WILL NEED A PUBLIC ACCESS EASEMENT RECORDED FOR IT | | | AS WELL AS HAVE SEATING INSTALLED. THE PASSAGEWAY WILL | | | END AT THE COVERED PUBLIC SPACE. | | | B. REPEAT COMMENT: PROVIDE THE DIMENSIONS FOR THE | | | NARROW POINTS SHOWN IN THE PASSAGEWAY. EX. BETWEEN THE | | | BUILDING WALLS, THE EDGE OF THE LANDSCAPE AREAS AND THE | | | COLUMNS. THESE ALL APPEAR TO BE CHOKE POINTS IN THE | | | PASSAGEWAY. | | | C. UPDATED COMMENT: THE WESTERN PORTION OF THE | | | PASSAGEWAY IS COVERED BY THE UPPER RESIDENTIAL STORIES, | | | INCLUDING BALCONIES. THIS AREA DOES NOT MEET THE | | | DEFINITION OF OVERHEAD COVER, WHICH INCLUDES AWNINGS, | | | CANOPIES, COLONNADES, PERGOLAS, TRELLISES OR OTHER | | | SIMILAR STRUCTURES, BUT DOES NOT INCLUDE AN AREA THAT | | | HAS THE UPPER STORIES OF THE BUILDING. THE 1,460 SQUARE | | | FEET OF COVERED AREA MAY NOT BE COUNTED TOWARD MEETING | | | THE OPEN SPACE REQUIREMENT. UPDATE ALL TABLES | | | ACCORDINGLY. | | | D. UPDATED COMMENT: THE OPEN SPACE MEASUREMENTS FOR THE | | | PASSAGEWAY MAY NOT INCLUDE AREAS WITHIN THE MINIMUM | | | SETBACK. PROVIDE THE REQUIRED NFPA SETBACK DIMENSION | | | FOR THE WEST SIDE OF THE 477 SOUTH ROSEMARY BUILDING | | | WHERE IT ABUTS THE PASSAGEWAY. THIS SETBACK AREA MAY | | | NOT BE COUNTED TOWARD MEETING THE PUBLIC OPEN SPACE | | | SQUARE FOOTAGE REQUIREMENT. ALTERNATIVELY, SINCE THE | | | PLANS STATE THAT THE OPENINGS WILL BE PROTECTED, | | | PROVIDE THE METHOD FOR THIS PROTECTION THAT WOULD | | | PERMIT THE NEW 575 SOUTH ROSEMARY BUILDING TO BE BUILT | | | TO THE PROPERTY LINE. NOTE: THE SQUARE FOOTAGE FOR THE | | | EGRESS WALKWAY BEHIND THE TWO DOORS ON THE WEST SIDE OF | | | 477 SOUTH ROSEMARY AVENUE CANNOT BE INCLUDED IN THE | | | PASSAGEWAY SINCE IT IS NOT PART OF THE PASSAGEWAY. | | | UPDATE ALL TABLES ACCORDINGLY. | | | | | | 10) UPDATED COMMENT: PROVIDE DIMENSION ON THE ELEVATION | | | DRAWINGS FOR THE PROJECTING ELEMENTS, WHICH INCLUDE THE | | | BALCONIES, BOTH RESIDENTIAL AND COMMERCIAL, THE AWNINGS | | | (EX. KEYNOTE 03 ON THE NORTH ELEVATION - TEMPERED GLASS | | | AND ALUMINUM AWNING). | | | | | | 11) NEW COMMENT: PROVIDE A SAMPLE FLOOR PLAN LEVEL | | | WHICH SHOWS THE SHORT BALCONIS AND ON THAT SHOWS THE | | | LONG BALCONIES FOR THAT SPECIFIC FLOOR. | | | | | | 12) UPDATED COMMENT: THE NET AREA DRAWINGS FOR THE | | | RESTAURANT, RETAIL AND OFFICE USES MUST INCLUDE THE | | | FOLLOWING AREAS AND ALL THE PARKING TABLES NEED TO BE | | | UPDATED ACCORDINGLY: | | | | | | A. RESTAURANT KITCHEN AND STORAGE - THESE AREAS ARE NOT | | | INCLUDED IN THE EXEMPTIONS LISTED IN THE NET INTERIOR | | | AREA DEFINITION OF SECTION 94-109 OF THE ZONING AND | | | LAND DEVELOPMENT REGULATIONS. | | | B. DOCK MANAGER OFFICE - THE LOADING DOCKS SERVICE BOTH | | | THE RESIDENTIAL AND THE NON-RESIDENTIAL COMPONENTS OF | | | THE BUILDING, SO DOCK MANAGER'S OFFICE NEEDS TO BE | | | INCLUDED IN THE PARKING CALCULATION. | | | C. SHOP BY THE LOADING DOCKS - IF THE SHOP ONLY | | | SERVICES THE RESIDENTIAL TOWER, THEN IT IS EXEMPTED; | | | HOWEVER, BY ITS LOCATION, IT APPEARS TO SERVICE THE | | | ENTIRE BUILDING AND MUST BE INCLUDED IN THE NET AREA. | | | D. MAINTENANCE OFFICES ON LOFT LEVEL 3 - MAINTENANCE | | | OFFICES SERVING THE NON-RESIDENTIAL PORTION OF THE | | | BUILDING MUST BE INCLUDE IN THE NET AREA. | | | E. RETAIL STORAGE - THESE AREAS ARE NOT INCLUDED IN THE | | | EXEMPTIONS LISTED IN THE NET INTERIOR AREA DEFINITION | | | SECTION 94-109 OF THE ZONING AND LAND DEVELOPMENT | | | REGULATIONS. | | | | | | 13) UPDATED COMMENT: THE SHARED PARKING MAY ONLY BE | | | USED IF THERE ARE NO PARKING SPACES DESIGNATED FOR A | | | PARTICULAR USE. THE RESPONSE STATES THAT THERE ARE NO | | | DESIGNATED PARKING SPACES WITHIN GARAGE D, WHEN IN FACT | | | THERE IS AT LEAST ONE AREA THAT IS GATED OFF FOR THE | | | USE OF THE GARDENS RESIDENTS. HOW WILL OPERATIONALLY | | | THE PARKING BE PROVIDED FOR THE USERS OF THE 575 SOUTH | | | ROSEMARY BUILDING- EX: WILL THE RESIDENTIAL TENANTS | | | HAVE AN AREA THAT IS DESIGNATED FOR "575 TOWER | | | RESIDENTIAL PARKING ONLY"? IF THIS IS THE CASE, THEN | | | THE SHARED PARKING MAY NOT BE USED. IF THERE WILL BE NO | | | DESIGNATED PARKING, THEN THE LEVEL III SITE PLAN | | | APPROVAL WILL CONTAIN THE DEVELOPMENT REGULATION THAT | | | NO LEASES CAN INCLUDE DESIGNATED PARKING IN THE D | | | GARAGE AND THAT NO BARRIERS MAY BE INSTALLED IN THE | | | GARAGE TO CREATE SEPARATED PARKING AREAS FOR SPECIFIC | | | TENANTS. | | | | | | 14) UPDATED COMMENT: THE RECENT PARKING TABLE PROVIDED | | | BY JORDAN RATHLEV SHOWS 724 PARKING SPACES AVAILABLE IN | | | GARAGE D. THIS TABLE NEEDS TO INCLUDE A SUB TABLE | | | SHOWING HOW THE 724 PARKING SPACES (OR AS MODIFIED BY | | | THE BUILDING DIVISION ADA COMMENT) ARE ALLOCATED TO THE | | | 575 SOUTH ROSEMARY AVENUE USERS (379 SPACES IF NOT | | | RESERVED), THE GARDENS RESIDENCES (33 + 2 GUEST), 477 | | | SOUTH ROSEMARY AVENUE (RETAIL AND OFFICE - DO ANY | | | OFFICE USERS HAVE RESERVED SPACES?), AND DESIGNATED | | | VALET. NOTE: THE PARKING AVAILABILITY TABLE INDICATES | | | THAT THERE IS EXCESS CAPACITY THROUGHOUT THE ENTIRE | | | CITYPLACE CPD, BUT STAFF IS TRYING TO VERIFY THAT | | | GARAGE D IS NOT OVER CAPACITY. | | | | | | 15) UPDATED COMMENT: THE TWO LOCATIONS WHERE THE | | | PEDESTRIAN CROSSING OF THE ACCESS EASEMENT NEED TO BE A | | | DIFFERENT PAVING MATERIAL THAN THE ACCESS EASEMENT | | | SURFACE SO THAT IT IS A VISUAL CLUE TO DRIVERS TO SLOW | | | DOWN. THIS CURRENTLY OCCURS THROUGH THE USE OF THE | | | EXISTING PAVER CROSSWALK, WHICH IS STAFF'S PREFERRED | | | OPTION. RAISED CROSSWALKS (EQUAL TO CURB LEVEL) SHOULD | | | BE EXPLORED. | | | | | | 16) NEW COMMENT: THE SIDEWALK AT THE NORTHWEST CORNER | | | OF THE TOWER INCLUDES A LANDSCAPE BED TO THE EDGE OF | | | THE BUILDING WHICH NARROWS THE SIDEWALK TO FIVE (5) | | | FEET IN WIDTH. THE LANDSCAPE BED NEEDS TO BE SHORTENED | | | SO THAT THE SIDEWALK AT THIS BLIND CORNER IS WIDER TO | | | PREVENT SITUATIONS WHERE SOMEONE NEEDS TO STEP INTO THE | | | ALLEY TO PASS IN OPPOSITE DIRECTIONS. | | | | | | 17) UPDATED COMMENT: STAFF HAS REVIEWED THE PROPOSED | | | RESIDENTIAL TOWER VALET PLAN AND DOES NOT SUPPORT THE | | | USE OF FERN STREET AND SOUTH ROSEMARY AVENUE TO RETURN | | | THE VEHICLES. THIS PUTS ADDITIONAL VEHICLE TRIPS ON | | | THESE TWO STREETS. AN ALTERNATIVE VALET PICK-UP IS | | | REQUIRED. WHERE IS THE VALET AREA IN THE GARAGE? | | | | | | 18) UPDATED COMMENT: THE PROPOSED OFFICE VALET PLAN IS | | | NOT CLEAR (THE BLUE DASHED LINE STOPS ON FERN STREET. | | | IT APPEARS THE INTENT IS TO HAVE THE VALETS DRIVE THE | | | CARS AROUND THE BLOCK AND USE FERN STREET, SOUTH | | | ROSEMARY AVENUE AND/OR SAPODILLA AVENUE. STAFF DOES NOT | | | SUPPORT THE USE OF THESE STREETS FOR THE VALET AS THIS | | | PUTS ADDITIONAL VEHICLE TRIPS ON THESE ROADWAYS. AN | | | ALTERNATIVE IS TO HAVE THE VALETS USE ONE OF THE | | | SERVICE AREA SPACES AS A TURNAROUND SPACE SO THEY CAN | | | GET THE GARAGE WITHOUT USING THE STREET NETWORK. | | | | | | 19) REPEAT COMMENT: PROVIDE THE PASSAGEWAY BICYCLE PAD | | | AND RACK DETAIL AND THE DIMENSIONS ON THE PLANS. THEY | | | DO NOT APPEAR TO MEET CODE REQUIREMENTS. NOTE: THE | | | BICYCLE PARKING AREA ALONG THE PEDESTRIAN PASSAGE HAS 6 | | | RACKS, NOT 3 AS LISTED ON THE PLANS. | | | | | | 20) REPEAT COMMENT: PROVIDE BICYCLE RACKS ALONG | | | ROSEMARY FOR THE RETAIL CUSTOMERS. THE HIBISCUS AND | | | ROSEMARY RECONSTRUCTION PLANS DO NOT SHOW ANY BICYCLE | | | RACKS ADJACENT TO 575 SOUTH ROSEMARY. | | | | | | 21) UPDATED COMMENT: PROVIDE GREEN ROOF DETAILS FOR | | | LEVELS 4 AND 5 AND THE TOWER ROOF. NOTE: IN ACCORDANCE | | | WITH THE DEVELOPMENT REGULATIONS, THE LEVEL 4 AND 5 AND | | | TOWER ROOF AREA THAT DO NOT INCLUDE THE MECHANICAL AND | | | SKYLIGHT AREAS MUST HAVE EITHER GREEN ROOF OR SOLAR. IF | | | SOLAR IS USED THIS NEEDS TO BE SHOWN. THE PLANS NEED TO | | | FACTOR THIS IN NOW. | | | | | | 22) UPDATED COMMENT: PLEASE TURN ON THE FOREGROUND | | | BUILDINGS ON THE NORTHWEST AND SOUTHWEST RENDERINGS ON | | | SHEET R0.01. | | | | | | 23) REPEAT COMMENT: PROVIDE A SHADOW STUDY. --- STAFF | | | HAS NOT SEEN A SHADOW STUDY AND THE DISC WAS NOT | | | INCLUDED WITH THE RESUBMITTAL. | | | | | | 24) REPEAT COMMENT: THE PHOTOMETRIC PLAN SHOWS LIGHTING | | | LEVELS AT THE CURB IN EXCESS OF THE PERMITTED ONE FOOT | | | CANDLE. ---- RESUBMITTED SHEET E-0.1 STILL SHOWS LIGHT | | | LEVELS AT THE CURB EXCEEDING ONE FOOTCANDLE. | | | | | | 25) REPEAT COMMENT: WHAT IS THE CONSTRUCTION PHASING | | | PLAN FOR THE BUILDING, ROSEMARY AND THE ALLEY? WILL THE | | | HIBISCUS RIGHT-OF-WAY, INCLUDING THE SIDEWALK, BE | | | COMPLETED PRIOR TO THE CONSTRUCTION OF THE BUILDING? | | | HOW WILL ACCESS BE PROVIDED TO THE TOWNHOUSES AND THE | | | SERVICE TO 477 SOUTH ROSEMARY DURING CONSTRUCTION? ---- | | | THE RESPONSE PRESENTED DOES NOT ADEQUATELY ADDRESS THE | | | QUESTION. | | | | | | 26) REPEAT COMMENT: EXPLAIN THE BAR IN THE RESIDENTIAL | | | LOBBY AREA. WHO DOES THIS SERVE? WHAT DOES IT SERVE? | | | --- THE RESPONSE PRESENTED DOES NOT ADDRESS THE | | | QUESTION. IF THIS IS A BAR, THAT IN ANYWAY COULD SERVE | | | THE PUBLIC, THEN YOU HAVE A NON-RESIDENTIAL USE HERE. | | | | | | 27) UPDATED COMMENT: RESOLUTION 304-18 REQUIRES THAT | | | THE ROOFTOP RAINWATER IS RETAINED ON-SITE AND IF NOT | | | USED THEN IT HAS ON-SITE INFILTRATION. USING AN | | | EXFILTRATION TRENCH TO DISCHARGE THE WATER OFF-SITE IS | | | NOT PERMITTED. DESCRIBE HOW THE ROOFTOP RAINWATER WILL | | | BE STORED ON-SITE. THE METHOD MAY IMPACT THE SITE PLAN. | | | THE PAVING AND DRAINAGE PLAN DOES NOT SEEM TO COVER | | | THIS REQUIREMENT. | | | | | | 28) UPDATED COMMENT: RESOLUTION 304-18 REQUIRES THAT | | | THE PLAZA AREAS OF THE SITE RETAIN THE STORMWATER | | | ON-SITE. IT APPEARS THAT THE PLAZA AREA ALONG SOUTH | | | ROSEMARY AVENUE IS DESIGNED TO FLOW OFF-SITE. | | | | | | CONDITION: THE AC UNITS MOUNTED ON RACKS ON THE WEST | | | BUILDING WALL OF 477 SOUTH ROSEMARY MUST BE REMOVED | | | PRIOR TO THE CONSTRUCTION OF THE 575 SOUTH ROSEMARY | | | BUILDING. | | | | | | CONDITION: WAYFINDING SIGNS ARE REQUIRED TO DIRECT | | | PEDESTRIANS FROM THE GARAGE TO THE OFFICE, RESIDENTIAL | | | AND RETAIL ENTRANCES. | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
06-12-2019 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
06-12-2019 |
Time |
11:28 |
Rev Time |
12.00 |
| Received By |
eschneid |
Date |
06-12-2019 |
Time |
11:28 |
Sent To |
|
|
| Notes |
| 2019-06-12 11:28:28 | CASE NO. PB 950 OOOOO | | | HIBISCUS TOWER | | | 575 SOUTH ROSEMARY AVENUE | | | | | | - CONTACT ERIC SCHNEIDER @ (561) 822-1446 | | | | | | - PLEASE PROVIDE RESPONSES TO REVIEW COMMENTS IN | | | WRITTEN FORMAT. | | | | | | - WHEN RESUBMITTING, PLEASE PROVIDE A MINIMUM OF ELEVEN | | | (11) PAPER COPIES AND AN ELECTRONIC COPY IN .PNG FORMAT | | | OF ALL PLANS. PLEASE NOTE THAT CHANGES ON THE | | | RESUBMITTED PLANS OR THE SUBMITTAL OF INFORMATION/PLANS | | | TO ADDRESS THE COMMENTS MAY RESULT IN ADDITIONAL | | | COMMENTS. | | | | | | - THE PPRC COMMENTS SHALL BE SUFFICIENTLY ADDRESSED AND | | | SUBMITTED TO THE PLANNING DIVISION BY 5 PM ON FRIDAY, | | | JUNE 28, 2019, TO BE ELIGIBLE TO BE SCHEDULED FOR THE | | | AUGUST 20, 2019 PLANNING BOARD MEETING. | | | | | | - PLEASE NOTE THAT IF THE PLANNING DIVISION HAS NOT | | | RECEIVED A RESPONSE TO THE PPRC COMMENTS WITHIN 60 DAYS | | | FROM THE DATE OF THE PPRC MEETING (BY AUGUST 12, 2019), | | | THE CASE SHALL BE CONSIDERED WITHDRAWN. ANY FURTHER | | | ACTION SHALL REQUIRE A NEW DEVELOPMENT APPLICATION. | | | | | | - PLEASE NOTE THAT YOU WILL BE PERMITTED ONE (1) | | | RESUBMITTAL AT NO ADDITIONAL COST. IF PREVIOUSLY-ISSUED | | | COMMENTS CONTINUE TO NOT BE SUFFICIENTLY ADDRESSED, THE | | | APPLICANT WILL BE ASSESSED A RESUBMITTAL FEE. SUCH FEE | | | WILL BE 20% OF THE ORIGINAL APPLICATION FEE ($600). | | | | | | - PUBLIC HEARING NOTIFICATION SIGNAGE SHALL BE POSTED | | | IN ACCORDANCE WITH THE REQUIREMENTS OF SECTION | | | 94-39(I)(5) OF THE ZONING AND LAND DEVELOPMENT | | | REGULATIONS. | | | | | | 1) THE CITYPLACE CENTER SUBAREA BOUNDARY LINE IS NOT | | | SHOWN IN THE SAME PLACE ON EVERY PLAN ALONG THE WEST | | | SIDE OF 477 SOUTH ROSEMARY. ALL PLANS MUST BE | | | CONSISTENT. | | | | | | 2) SHEET V-2 SHOWS A PORTION OF THE 477 SOUTH ROSEMARY | | | BUILDING WITHIN THE CITYPLACE CENTER SUBAREA. THIS | | | OVERLAPPING SQUARE FOOTAGE MUST BE COUNTED AS PART OF | | | THE FAR CALCULATION. | | | | | | 3) THE 50 FOOT MAXIMUM PODIUM SETBACK LINE FOR ROSEMARY | | | IS NOT IN THE CORRECT LOCATION. IT SCALES TO | | | APPROXIMATELY 56 FEET FROM THE ROSEMARY CENTERLINE. | | | | | | 4) STAFF HAS REVIEWED THE FAR CALCULATIONS AND NOTED | | | THE FOLLOWING: | | | | | | A. ON THE GROUND LEVEL, THE TWO VESTIBULES, THE SHOP | | | AND THE FIRE COMMAND ROOM ARE REQUIRED TO BE COUNTED IN | | | THE FAR SQUARE FOOTAGE. | | | B. ON THE RESIDENTIAL LEVELS, THE VESTIBULE FOR THE | | | TRASH CHUTES IS REQUIRED TO BE COUNTED IN THE FAR | | | SQUARE FOOTAGE (THE TRASH CHUTES THEMSELVES ARE | | | CORRECTLY NOT COUNTED). | | | C. ON THE RESIDENTIAL LEVELS, PROVIDE INFORMATION ON | | | WHAT THE ROOM ADJACENT TO THE TRASH CHUTE VESTIBULE IS. | | | DEPENDING ON THE USE, THIS MAY NEED TO BE COUNTED IN | | | THE FAR SQUARE FOOTAGE. | | | | | | 5) PROVIDE THE DIMENSION LINE SHOWING THE FULL HEIGHT | | | OF THE PODIUM, PLUS THE HIGHEST POINT OF THE HEIGHT | | | ENCROACHMENT, MUST BE SHOWN ON THE ELEVATION PLANS. | | | STAFF MEASURES THE HIGHEST POINT OF PODIUM, INCLUDING | | | VERTICAL ENCROACHMENTS, AT APPROXIMATELY 63 FEET, WHICH | | | EXCEEDS THE PERMITTED PODIUM HEIGHT ALLOWANCE. NOTE: | | | INCLUDE THE CABANAS, WITH THE HEIGHT, ON THE ELEVATION | | | DRAWINGS. | | | | | | 6) THE FACADE ARTICULATION DIAGRAMS AND MATRICES DO NOT | | | PROVIDE THE DIMENSIONS FOR THE VARIOUS REQUIRED | | | FEATURES. STAFF MUST BE ABLE TO VERIFY COMPLIANCE WITH | | | THE REQUIREMENTS. NOTE: THE LETTERS ON THE DIAGRAMS ON | | | SHEETS A0.01.1 AND A0.01.2 MUST KEY TO TEXT IN THE | | | TABLE. | | | | | | 7) PLANAR BREAKS ARE REQUIRED FOR ALL LEVELS OF THE | | | PODIUM. THE PLANS DO NOT SHOW EVIDENCE THAT THIS | | | OCCURS. | | | | | | 8) STAFF DOES NOT FEEL THAT THE TOWER HAS ENOUGH | | | ARTICULATION GIVEN ITS SCALE, MASS AND FACADE LENGTH. | | | | | | 9) PROVIDE DESCRIPTION OF HOW THE MATERIALS FOR THE 30 | | | FOOT ARCHITECTURAL TREATMENT ALONG WEST STREET (THE | | | PORTION THAT IS NOT FENESTRATION) WILL SATISFY THE | | | REQUIREMENT. | | | | | | 10) THE ACTIVE USE DIAGRAMS CONTAIN INACCURACIES | | | (INCONSISTENT FRONTAGES, INCORRECT TOTALS, AND | | | INCORRECT MEASURE POINTS). PLEASE REVIEW THE DRAWINGS | | | FOR ACCURACY. ANY CHANGES NEED TO BE REFLECTED ON THE | | | ACTIVE USE SUMMARY TABLE ON SHEET A0.01 | | | | | | A. IT APPEARS THAT THE HIBISCUS FRONTAGE MEETS THE | | | ACTIVE USE REQUIREMENTS. | | | B. LEVEL 3 DOES NOT MEET THE MINIMUM 60% ACTIVE USE | | | REQUIREMENT. THE OUTDOOR DINING AND PASSAGEWAY MAY NOT | | | BE COUNTED AS ACTIVE USE ABOVE THE GROUND FLOOR. | | | | | | 11) THE PORTION OF THE BUILDING ALONG ROSEMARY BEHIND | | | THE OUTDOOR DINING DOES NOT MEET THE SETBACK | | | REQUIREMENT THAT THE BUILDING BE BETWEEN 35 AND 50 FEET | | | FROM THE CENTERLINE OF ROSEMARY. IF THE OUTDOOR DINING | | | AREA IS DESIGNED AS A PUBLIC OPEN SPACE, THEN THE | | | BUILDING AS DESIGNED MEETS THE SETBACK ALLOWANCES. | | | PLEASE PROVIDE HOW THE OUTDOOR DINING AREA COMPLIES | | | WITH ONE OF THE TYPES OF PUBLIC OPEN SPACE. | | | | | | 12) THE POOL DECK AND LEVEL 5 GREEN ROOF NEED TO HAVE | | | NOTES AS TO WHICH TYPE OF PRIVATE OPEN SPACE THEY ARE, | | | SO THAT STAFF CAN VERIFY COMPLIANCE WITH THE REQUIRED | | | STANDARDS. | | | | | | 13) PRIVATE OPEN SPACE IS FOR THE USE OF THE BUILDING | | | RESIDENTS. PLEASE DESCRIBE HOW THE LEVEL 5 GREEN ROOF | | | AND THE LEVEL 4 ROOFTOP GARDEN WILL BE USED BY THE | | | RESIDENTS. | | | | | | 14) PUBLIC OPEN SPACE IS NOT PERMITTED TO BE ADJACENT | | | TO BUILDING MECHANICAL SPACES, EQUIPMENT OR SERVICE | | | AREAS, ETC. | | | | | | A. THE PORTION OF THE PUBLIC OPEN SPACE ADJACENT TO | | | WEST STREET IS ADJACENT TO TRANSFORMERS THAT ARE | | | REMAINING FOR 477 SOUTH ROSEMARY. THE TRANSFORMERS MUST | | | BE SCREENED FROM VIEW OF THE PROPOSED PUBLIC OPEN | | | SPACE, OR THE AREA MAY NOT BE COUNTED AS PUBLIC OPEN | | | SPACE. | | | B. THERE ARE AC UNITS MOUNTED ON RACKS THAT ARE ON THE | | | BUILDING WALL OF 477 SOUTH ROSEMARY. THIS MECHANICAL | | | EQUIPMENT MUST ALSO BE SCREENED FROM THE PUBLIC OPEN | | | SPACE. PLEASE NOTE: IT APPEARS THAT THIS MECHANICAL | | | EQUIPMENT DIRECTLY CONFLICTS WITH THE PROPOSED TREES | | | ALONG THE WALL. PROVIDE A DETAIL ON HOW THE WALL | | | MOUNTED MECHANICAL EQUIPMENT DOES NOT INTERFERE WITH | | | THE PROPOSED LANDSCAPE AND ITS LONG TERM GROWTH. | | | | | | 15) PUBLIC OPEN SPACE - PASSAGE REQUIREMENTS | | | | | | A. THE PASSAGE IS REQUIRED TO HAVE A MINIMUM OF 25 FEET | | | OPENING ON BOTH SIDES. | | | B. A PASSAGEWAY IS REQUIRED TO CONNECT TWO OR MORE | | | PUBLIC RIGHTS-OF-WAY OR PUBLIC SPACES. WEST STREET IS | | | NOT A PUBLIC RIGHT-OF-WAY (IT IS AN ACCESS EASEMENT) SO | | | IT NEEDS TO INCLUDE PUBLIC ACCESS AND VISUAL | | | IMPROVEMENTS TO ALLOW IT TO QUALIFY AS A PUBLIC SPACE. | | | SEE COMMENT #29 FOR ACCESS IMPROVEMENTS AND COMMENT #14 | | | FOR VISUAL ITEMS THAT NEED TO BE ADDRESSED. | | | C. PROVIDE THE DIMENSIONS FOR THE NARROW POINTS SHOWN | | | IN THE PASSAGEWAY. EX. WALL TO DECORATIVE POT, | | | LANDSCAPE AREA TO COLUMNS, COLUMNS TO OFFICE ENTRANCE | | | WALL, ETC. THESE ALL APPEAR TO BE CHOKE POINTS IN THE | | | PASSAGEWAY. | | | D. THE WESTERN PORTION OF THE PASSAGEWAY IS COVERED BY | | | THE UPPER RESIDENTIAL STORIES, INCLUDING BALCONIES. | | | PROVIDE THE CALCULATION TO VERIFY THAT NO MORE THAN 25% | | | OF THE REQUIRED OPEN SPACE IS COVERED. | | | | | | 16) OPEN SPACE MEASUREMENTS SHALL NOT INCLUDE AREAS | | | WITHIN THE MINIMUM SETBACK. PROVIDE THE SETBACK | | | DIMENSION REQUIRED BY THE NFPA REQUIREMENTS FOR THE | | | PORTIONS OF THE HIBISCUS TOWER LOCATED ADJACENT TO THE | | | EXISTING 477 SOUTH ROSEMARY BUILDING. THIS SETBACK AREA | | | MAY NOT BE COUNTED TOWARD MEETING THE PUBLIC OPEN SPACE | | | SQUARE FOOTAGE REQUIREMENT. | | | | | | 17) THE JUSTIFICATION STATEMENT COMPLIANCE TABLE AND | | | THE PLANS SHOW DIFFERING VALUES FOR THE PROVIDED AMOUNT | | | OF OPEN SPACE, BOTH PRIVATE AND PUBLIC. | | | | | | 18) PROVIDE DIMENSION ON THE ELEVATION DRAWINGS FOR THE | | | PROJECTING ELEMENTS. THIS INCLUDES CLEARANCE HEIGHT | | | DIMENSIONS FOR THE AWNINGS AND THE TOWER BALCONIES. | | | | | | 19) THE ALUMINUM AWNING ALONG HIBISCUS HAS A 14 FOOT | | | CLEARANCE AND WILL EXTEND INTO THE BLACK OLIVE TREES IN | | | THE PLANTER AREAS ADJACENT TO THE DROP OFF. THE ZLDR DO | | | NOT PERMIT HORIZONTAL ENCROACHMENTS THAT INTERFERE WITH | | | NORMAL ENVELOP OF STREET TREE CANOPY. | | | | | | 20) A 24 INCH DEEP ALUMINUM AWNING IS NOT PERMITTED. | | | AWNINGS ARE REQUIRED TO PROJECT A MINIMUM OF 3 FEET | | | FROM THE BUILDING. THE ELEVATION PLANS LABEL THIS AS AN | | | ALUMINUM SUNSHADE. SINCE ONLY ARCHITECTURAL FEATURES | | | MAY EXTEND 2 FEET FROM THE BUILDING, THIS NEEDS TO BE | | | LABELED AS AN ARCHITECTURAL FEATURE ON THE PLANS. | | | | | | 21) PROVIDE THE STREET LEVEL ELEVATION BLOW-UPS WITHOUT | | | THE LANDSCAPE LAYER. STAFF IS UNABLE TO SEE DETAILS. | | | | | | 22) THE DATA IN THE PARKING TABLE FOR THE RETAIL, | | | RESTAURANT AND OFFICE LINES IS LESS SQUARE FOOTAGE THAN | | | WHAT IS SHOWN IN THE PROJECT DATA TABLE. ALL VALUES | | | SHALL BE CONSISTENT AND CORRECT. | | | | | | 23) PROVIDE NET AREA DRAWINGS FOR THE RESTAURANT, | | | RETAIL AND OFFICE USES SO THAT STAFF CAN VERIFY THE | | | PARKING SQUARE FOOTAGE PRESENTED FOR THE PARKING | | | CALCULATIONS. | | | | | | 24) THE SHARED PARKING MAY ONLY BE USED IF THERE ARE NO | | | PARKING SPACES DESIGNATED FOR A PARTICULAR USE. THIS | | | THEN DOES NOT PERMIT THE ABILITY TO HAVE DESIGNATED | | | PARKING FOR EITHER THE RESIDENTIAL OR OFFICE USERS. | | | | | | 25) THE PROVIDED PARKING TABLE (RE-REVIEW ONCE COMMENT | | | #S 22-24 ARE ADDRESSED) SHOWS 390 PARKING SPACES | | | REQUIRED FOR THE NEW HIBISCUS TOWER VS. THE 222 PARKING | | | SPACES REQUIRED FOR THE MACY?S. THE PARKING | | | AVAILABILITY TABLE PROVIDED BY JORDAN RATHLEV NEEDS TO | | | BE FURTHER BROKEN DOWN TO VERIFY THAT THE HIBISCUS | | | TOWER, THE SAPODILLA RESIDENCES AND 477 S. ROSEMARY | | | HAVE SUFFICIENT PARKING SPACES IN THE GARAGE. NOTE: THE | | | PARKING AVAILABILITY TABLE INDICATES THAT THERE IS | | | EXCESS CAPACITY THROUGHOUT THE ENTIRE CITYPLACE CPD. | | | | | | 26) PROVIDE THE GARAGE PLAN SHOWING WHERE THE | | | RESIDENTIAL PARKING WILL OCCUR, TO INCLUDE ANY | | | BARRIERS, AS WELL AS THE LOCATIONS OF THE REQUIRED | | | CHARGING STATIONS AND CAR SHARE STATION. | | | | | | 27) THE GARAGE LAYOUT IS AFFECTED BY THE NEW BRIDGE | | | LOCATION SO THIS WILL NEED TO BE INCLUDED AS PART OF | | | THIS APPLICATION AND SHOWN ON THE PLANS REQUIRED AS | | | PART OF #26. NOTE: A SETBACK WAIVER IS REQUIRED FOR THE | | | BRIDGE. | | | | | | 28) SHOW THE ADA ROUTE FROM THE ADA PARKING SPACES IN | | | THE GARAGE TO THE OFFICE AND RETAIL ENTRANCES. | | | | | | 29) THE WEST STREET PEDESTRIAN CROSSING LOCATIONS, TO | | | INCLUDE IN FRONT OF THE LOADING DOCKS, MUST BE CLEARLY | | | DEFINED, PREFERABLY THROUGH THE USE OF A DIFFERENT | | | PAVING MATERIAL THAN THE ROADWAY SURFACE. | | | | | | 30) YOU WILL BE REQUIRED TO PROVIDE WAY FINDING SIGNS | | | FROM THE GARAGE TO THE OFFICE, RESIDENTIAL AND RETAIL | | | ENTRANCES. | | | | | | 31) EXPLAIN THE USE OF THE RESIDENTIAL DROP OFF. IS THE | | | INTENTION TO HAVE A VALET FOR THE TOWER AT THIS | | | LOCATION? IF SO, PROVIDE THE VALET OPERATION PLAN, TO | | | INCLUDE WHERE THE VALET AREA IS IN THE GARAGE. | | | | | | 32) EXPLAIN THE USE OF THE OFFICE DROP OFF. IS THE | | | INTENTION TO HAVE A VALET FOR THE OFFICE AT THIS | | | LOCATION? IF SO, PROVIDE THE VALET OPERATION PLAN, TO | | | INCLUDE WHERE THE VALET AREA IS IN THE GARAGE. | | | | | | 33) PROVIDE THE BICYCLE WALL INSTALLATION DETAIL AT A | | | BIGGER SCALE. IT IS NOT LEGIBLE ON THE PAPER PLANS. | | | | | | 34) PROVIDE THE DIMENSIONS OF THE BICYCLE STORAGE ROOMS | | | ON THE PLANS. STAFF NEEDS TO VERIFY THE NUMBER OF | | | BICYCLES THAT CAN BE STORED. | | | 35) PROVIDE THE PASSAGEWAY BICYCLE PAD AND RACK DETAIL | | | AND THE DIMENSIONS ON THE PLANS. THEY DO NOT APPEAR TO | | | MEET CODE REQUIREMENTS. | | | | | | 36) PROVIDE BICYCLE RACKS ALONG ROSEMARY FOR THE RETAIL | | | CUSTOMERS. ZONING STAFF HAS NOT SEEN THE PLANS FOR THE | | | HIBISCUS OR ROSEMARY RECONSTRUCTION SO IF RACKS ARE | | | INCLUDED IN THESE PLANS SHOW THEM ON THE HIBISCUS TOWER | | | PLANS TO ADDRESS THIS COMMENT. | | | | | | 37) THE LANDSCAPE PLANS SHOW TRA, BUT THIS IS NOT | | | LISTED ON THE PLANT LIST. | | | | | | 38) PROVIDE GREEN ROOF DETAILS FOR LEVELS 4 AND 5 AND | | | THE TOWER ROOF. NOTE: IN ACCORDANCE WITH THE | | | DEVELOPMENT REGULATIONS, THE LEVEL 4 ROOF THAT DOES NOT | | | INCLUDE THE MECHANICAL AND SKYLIGHT AREAS. IF SOLAR IS | | | USED THIS NEEDS TO BE SHOWN. THE PLANS NEED TO FACTOR | | | THIS IN NOW. | | | | | | 39) THE LANDSCAPE PLAN SET LABELS BOLLARDS AT THE | | | CORNER OF ROSEMARY AND HIBISCUS AS LIGHT POLES. | | | | | | 40) PROVIDE VERIFICATION THAT THE FPL TRANSFORMERS | | | BEING REMOVED DO NOT SERVICE 477 SOUTH ROSEMARY. NOTE: | | | ANY TRANSFORMERS THAT ARE REQUIRED TO BE RELOCATED MUST | | | BE SHOWN IN THEIR NEW LOCATION AS PART OF THIS PROJECT. | | | | | | 41) THE GROUND FLOOR PLAN ON SHEET A1.01 MUST SHOW ALL | | | THE PROPOSED MECHANICAL EQUIPMENT. IT FAILS TO SHOW THE | | | PROPOSED BACKFLOW AND GAS METERS ALONG THE WEST STREET | | | SHOWN ON SHEET P1.01. NOTE: STAFF WILL NOT SUPPORT THE | | | PROPOSED LOCATION OF THE MECHANICAL EQUIPMENT IT IS | | | BLOCKING THE SIDEWALK. ADDITIONALLY, THE CITYPLACE DRI | | | REQUIRES THE SCREENING OF MECHANICAL EQUIPMENT, WHICH | | | THE PROPOSED PLAN DOES NOT SHOW. | | | | | | 42) PROVIDE THE RENDERING OF THE BUILDING IN CONTEXT | | | (SIMILAR TO R0.02) FROM THE NORTH, SOUTH AND WEST | | | | | | 43) PROVIDE GROUND LEVEL RENDERINGS OF THE BUILDING | | | FROM WEST ON HIBISCUS, AND NORTH AND SOUTH ALONG | | | ROSEMARY. | | | | | | 44) PROVIDE A SHADOW STUDY. | | | | | | 45) THE PHOTOMETRIC PLAN SHOWS LIGHTING LEVELS AT THE | | | CURB IN EXCESS OF THE PERMITTED ONE FOOT CANDLE. | | | | | | 46) WHAT IS THE CONSTRUCTION PHASING PLAN FOR THE | | | BUILDING, ROSEMARY AND THE ALLEY? WILL THE HIBISCUS | | | RIGHT-OF-WAY, INCLUDING THE SIDEWALK, BE COMPLETED | | | PRIOR TO THE CONSTRUCTION OF THE BUILDING? HOW WILL | | | ACCESS BE PROVIDED TO THE TOWNHOUSES AND THE SERVICE TO | | | 477 SOUTH ROSEMARY DURING CONSTRUCTION? | | | | | | 47) EXPLAIN THE BAR IN THE RESIDENTIAL LOBBY AREA. WHO | | | DOES THIS SERVE? WHAT DOES IT SERVE? | | | | | | 48) TURN THE LIFE SAFETY DISTANCE LAYER OF ON THE | | | RESUBMITTAL PLANS. | | | | | | 49) DESCRIBE HOW THE ROOFTOP RAINWATER WILL BE STORED | | | ON-SITE. THE METHOD MAY IMPACT THE SITE PLAN. THE | | | PAVING AND DRAINAGE PLAN DOES NOT SEEM TO COVER THIS | | | REQUIREMENT. | | | | | | 50) THE PLAZA ON-SITE STORMWATER RETENTION NEEDS TO BE | | | EXPLAINED SINCE THE DIFFERING METHODS AFFECT THE SITE | | | PLAN. THE PAVING AND DRAINAGE PLAN DOES NOT SEEM TO | | | COVER THIS REQUIREMENT. | | | | | | 51) STAFF IS STILL ANALYZING THE VEHICLE TRIP | | | GENERATION AS IT RELATES TO THE TROLLEY OPERATION | | | CONTRIBUTION. | | | | | | | | | |
|
|
| |